FH_EN_H_thinbr-window-1.pdf

Page 1

interior works not displayed

wall thickness variable

window installation with windproofing, airproofing and fixation according to specifications of the window manufacturer

insulation of window profile min. 30 mm

insulation thickness variable

30

system-related joint sealant backfill material (PE-round cord) trowel cut or rendering strip

joint sealing tape mesh corner angle

jointing mortar

Feldhaus corners 9 or 14 mm

Feldhaus thin bricks 9 or 14 mm laying mortar about 3 mm priming render 2nd step applied wet-on-wet optionally only level out the anchor heads reinforcing mesh in the upper third priming render 1st step insulation material adhesive mortar min. 60% surface percentage wall construction

Feldhaus Klinker Vertriebs-GmbH Nordring 1, 49196 Bad Laer Zentrale +49 (0) 54 24 29 20 0

Note: This detail is a general proposition which schematically shows a possible execution. Usability and completeness are to be checked under personal responsability regarding the particular construction project.

www.feldhaus-klinker.de

Related works are only shown schematically. Content The specifications of corresponding standards, relevant system authorisations and data sheets are to be respected. All specifications and assumptions are to be customised to local conditions.

window flush with masonry horizontal cut

M

1:5

sheet FH_EN_H_thinbr-window-1 date

03.10.2018