gradient inwards
system-related joint sealant backfill material (PE-round cord)
trowel cut or rendering strip roof sealing according to flat roof guideline
joint sealing tape
gradient > 2%
jointing mortar Feldhaus thin bricks 9 or 14 mm
laying mortar about 3 mm priming render 2nd step applied wet-on-wet optionally only level out the anchor heads anchor sleeve anchor plate anchors for the insulation material (dowelled through the mesh)
interior works not displayed
reinforcing mesh in the upper third priming render 1st step insulation material adhesive mortar min. 60% surface percentage wall construction
wall thickness variable
insulation thickness variable Feldhaus Klinker Vertriebs-GmbH Nordring 1, 49196 Bad Laer Zentrale +49 (0) 54 24 29 20 0
Note: This detail is a general proposition which schematically shows a possible execution. Usability and completeness are to be checked under personal responsability regarding the particular construction project.
www.feldhaus-klinker.de
Related works are only shown schematically. Content The specifications of corresponding standards, relevant system authorisations and data sheets are to be respected. All specifications and assumptions are to be customised to local conditions.
attic vertical cut
M
1:5
sheet FH_EN_V_thinbr-attic-1 date
03.10.2018