wall thickness variable
insulation thickness variable
wall construction adhesive mortar min. 60% surface percentage insulation material priming render 1st step reinforcing mesh in the upper third anchors for the insulation material (dowelled through the mesh) anchor plate anchor sleeve priming render 2nd step applied wet-on-wet optionally only level out the anchor heads laying mortar about 3 mm Feldhaus thin bricks 9 or 14 mm jointing mortar
sealing according to DIN 18195 system-related bonding on sealing
sheet metal covering roof sealing according to flat roof guideline gradient of the water bearing layer > 2%
Feldhaus Klinker Vertriebs-GmbH Nordring 1, 49196 Bad Laer Zentrale +49 (0) 54 24 29 20 0
Note: This detail is a general proposition which schematically shows a possible execution. Usability and completeness are to be checked under personal responsability regarding the particular construction project.
www.feldhaus-klinker.de
Related works are only shown schematically. Content The specifications of corresponding standards, relevant system authorisations and data sheets are to be respected. All specifications and assumptions are to be customised to local conditions.
>= 300 mm
heat-insulating construction material
>= 150 mm
joint sealing tape
splash water areas
plinth profile
minimum height of sealing
plinth plate, min. 300 mm above top level of balcony covering
balcony connection to thin bricks with offset and sheet metal covering vertical cut
M
1:5
sheet FH_EN_V_thinbr-balcony-2 date
03.10.2018