wall thickness variable
insulation thickness variable
finishing render and optionally painting
cement-based sealing slurry, about 50 mm above profile render closing profile backfill material (PE-round cord) system-related joint sealant joint sealing tape system-related clinker brick end profile render closing profile cavities are to be insulated completely
jointing mortar Feldhaus thin bricks 9 or 14 mm laying mortar about 3 mm priming render 2nd step applied wet-on-wet optionally only level out the anchor heads reinforcing mesh in the upper third priming render 1st step insulation material adhesive mortar min. 60% surface percentage
wall construction
Feldhaus Klinker Vertriebs-GmbH Nordring 1, 49196 Bad Laer Zentrale +49 (0) 54 24 29 20 0
Note: This detail is a general proposition which schematically shows a possible execution. Usability and completeness are to be checked under personal responsability regarding the particular construction project.
www.feldhaus-klinker.de
Related works are only shown schematically. Content The specifications of corresponding standards, relevant system authorisations and data sheets are to be respected. All specifications and assumptions are to be customised to local conditions.
transition thin bricks -render 1 with field limitation joint vertical cut
M
1:5
sheet FH_EN_V_thinbr-trans-render1 date
03.10.2018