FiberConnect®
FiberTech ®
FiberSwitch ®
FiberSplit®
199
FiberConnect® Singlemode fiber E9/125
Fiber optic cables (SM / MM)
according to ITU-T Rec. and IEC 60 793-2-50
Optical core
Optical cladding
Primary coating
Singlemode fiber E9/125 acc. to ITU-T Rec. and IEC 60 793-2-50
Singlemode fiber E9/125 according to ITU-T Rec. G.652.D, ITU-T Rec. G.657.A1, ITU-T Rec. G.657.A2/B2 G.657.A2/B2, ITU-T Rec. G.657.B3 and IEC 60 793-2-50 other fiber types e. g. ITU-T G.655 or ITU-T G.657 on request
Geometric/mechanical properties Cladding diameter [µm]
125 ± 0.7
Mode field/cladding concentricity error [µm] < 0.5
Coating diameter [µm]
245 ± 10
Excentricity of coating [µm]
Cladding non-circularity
<1 %
Screen test
Transmission properties
Wavelength [nm]
(fiber type A) max. [dB/km] Attenuation multi-fiber loose tube (fiber type B) max. [dB/km] Dispersion coefficient max. [ps/nm × km] Zero dispersion wavelength [nm] Zero dispersion slope [ps/nm2 × km] Cut-Off wavelength (cabled) [nm] Polarization mode dispersion [ps/ km ] Effective group index of refraction Mode field diameter at 1310 µm [µm]
www.leoni-fiber-optics.com
1 % Expansion for 1 s (ɋ 100 kpsi)
Fiber type A (tight buffered fiber) resp. B (multi fiber loose tube)
Fiber type E resp. Fiber type P
Fiber type U
Fiber type K
according to ITU-T G.652.D and ISO 11801 Type OS 2 IEC 60793-2-50 B1.3
according to ITU-T G.657.A1 IEC 60793-2-50 B6_a1
according to ITU-T G.657.A2/B2 IEC 60793-2-50 B6_a2
according to ITU-T G.657.B3 IEC 60793-2-50 B6_b3
1310
1550
0.38
0.28
0.36
0.22
Attenuation max. [dB/km] Attenuation tight buffered fibers
< 12
1310 0.36
1550 0.22
1310 0.36
1550 0.22
1310 0.36
1550 0.22
3.5 18 1302 – 1322
3.5 18 1302 – 1322
3.5 18 1304 – 1324
3.5 18 1304 – 1324
≤ 0.090
≤ 0.092
≤ 0.092
≤ 0.092
≤ 1260 ≤ 0.2 1.4695 1.4701 9.2 ±0.4
≤ 1260 ≤ 0.2 1.4695 1.4701 8.9 ±0.4
≤ 1260 ≤ 0.2 1.4670 1.4677 8.6 ±0.4
≤ 1260 ≤ 0.2 1.4670 1.4680 8.6 ±0.4
09
200
FiberConnect® Multimode fiber G50/125
Fiber optic cables (SM / MM)
according to IEC 60 793-2-10
Radiation resistance All fiber types are also avaiOptical core
lable in a radiation-hard version or with approval
Optical cladding
according to MIL-PRF-49291C (6B MMF 62.5/125; 1B MMF 50/125; 7C SMF 9/125).
Primary coating
Multimode fiber Multimod OM3 and OM4 fibers are available in bend-insensitive quality on request.
G50/125 G50/12 acc to. to IEC 60 793-2-10
Multimode fiber G50/125 according to IEC 60 793-2-10 Geometric/mechanical properties Core diameter [µm]
50 ± 2,5
Cladding non-circularity (%)
<1
Cladding diameter [µm]
125 ± 1
Core/cladding concentricity error [µm]
< 1.5
Coating diameter [µm]
245 ± 10
Excentricity of coating [µm]
< 10
Core non-circularity
<5 %
Screen test
1 % expansion for 1 s (ɋ 100 kpsi)
Conventional fibers Transmission properties
09
Bend-insensitive fibers
Fiber type F
Fiber type G
Fiber type H
Fiber type I
Fiber type J
Fiber type X
Fiber type V
Fiber type W
(OM2) IEC 60793-2-10 A1a.1
(OM2+) IEC 60793-2-10 A1a.1
(OM2++) IEC 60793-2-10 A1a.1
(OM3) IEC 60793-2-10 A1a.2
(OM4) IEC 60793-2-10 A1a.3
(OM2BI) IEC 60793-2-10 A1a.1
(OM3BI) IEC 60793-2-10 A1a.2
(OM4BI) IEC 60793-2-10 A1a.3
Wavelength [nm]
850
1300
850
1300
850
1300
850
1300
850
1300
850
1300
850
1300
850
1300
Attenuation max. [dB/km]
3.0
1.0
2.7
0.8
2.7
0.7
2.5
0.7
2.5
0.7
3.0
1.0
2.5
0.7
2.5
0.7
Bandwidth OFL min. [MHz × km]
500
500
500
1000
600
500
3500
500
500
500
1500
500
3500
500
1200 1500
Bandwidth EMB min. [MHz × km]
2000
4700
2000
4700
Effective group index of refraction
1.483 1.478 1.483 1.478 1.483 1.478 1.483 1.478 1.483 1.475 1.483 1.478 1.483 1.478 1.483 1.478
Numerical aperture
0.200 ± 0.020
0.200 ± 0.015
Applications and link lengths G50/125 F
G
H
I
J
X
V
W
Type according to ISO 11801: 09/2002
OM2
OM2+
OM2++
OM3
OM4
OM2BI
OM3BI
OM4BI
Gigabit Ethernet 1000BASE-SX
(850 nm)
500 m
525 m
750 m
1,000 m
1,040 m
500 m
1,000 m
1,040 m
Gigabit Ethernet 1000BASE-LX
(1300 nm)
550 m
1,000 m
2,000 m
550 m
600 m
550 m
550 m
600 m
10 Gigabit Ethernet 10GBASE-SX
(850 nm)
300 m*
550 m
300 m
550 m
300 m
300 m
300 m
300 m
10 Gigabit Ethernet 10GBASE-LX4 (1310 nm WDM) * 10 GE link length acc. to ISO 11801.2
www.leoni-fiber-optics.com
FiberConnect®
FiberTech ®
FiberSwitch ®
FiberSplit®
201
FiberConnect® Multimode fiber G62.5/125 and G100/140
Radiation resistance All fiber types are also avaiOptical core
lable in a radiation-hard version or with approval
Optical cladding
according to MIL-PRF 49291C (6B MMF 62.5/125; 1B MMF 50/125; 7C SMF 9/125).
Primary coating
Fiber optic cables (SM / MM)
according to IEC 60 793-2-10
Multimode fiber Multimod G62.5/125 G62.5/ acc. to IEC 60 793-2-10
Multimode fiber G62.5/125 according to IEC 60 793-2-10
Multimode fiber G100/140 according to IEC 60 793-2-10
Geometric/mechanical properties
Geometric/mechanical properties, fiber type Q
Core diameter [µm]
62.5 ± 3
Core diameter [µm]
100 ± 4
Cladding diameter [µm]
125 ± 2
Cladding diameter [µm]
140 ± 3
Coating diameter [µm]
245 ± 10
Coating diameter [µm]
250 ± 15
Core non-circularity
<5 %
Core non-circularity
<6 %
Cladding non-circularity
<1 %
Cladding non-circularity
<2 %
Core/cladding concentricity error [µm]
< 1.5
Core/cladding concentricity error [µm]
< 3.0
Excentricity of coating [µm]
< 10
Excentricity of coating [µm]
< 12.5
Screen test
1 % Expansion for 1 s (ɋ 100 kpsi)
Übertragungseigenschaften Wavelength [nm] Attenuation max. [dB/km] Bandwidth OFL min. [MHz × km] Effective group index of refraction Numerical aperture
Screen test
Fiber type L (OM1) IEC 60793-2-10 A1b
Fiber type M (OM1+) IEC 60793-2-10 A1b
Fiber type Q IEC 60793-2-10 A1d
850 1300 3.2 0.9 200 500 1.497 1.493 0.275 ± 0.015
850 1300 3.0 0.8 300 800 1.497 1.493 0.275 ± 0.015
850 1300 5.0 2.0 100 100 1.497 1.492 0.290 ± 0.020
Applications and link lengths G62.5/125 Type according to ISO 11801: 09/2002 Gigabit Ethernet 1000BASE-SX
(850 nm)
Gigabit Ethernet 1000BASE-LX
(1300 nm)
10 Gigabit Ethernet 10GBASE-SX
(850 nm)
10 Gigabit Ethernet 10GBASE-LX4
(1310 nm WDM)
* 10 GE link length acc. to ISO 11801.2
www.leoni-fiber-optics.com
1 % Expansion for 1 s (ɋ 100 kpsi)
L
M
OM1 350 m 550 m
OM1+ 500 m 1,000 m
09
202
FiberConnect® Buffered optical fibers
Fiber optic cables (SM / MM)
Buffered fibers for the modular structure of the tight buffered fiber cables
STB900 – semi-tight buffered fiber
TB900L – tight buffered fiber
Optical fiber
Optical fiber
Gel filling
Silicone buffer
Secondary coating
Secondary coating
V-…
Properties/applications Q
For splicing as pigtail
Q
As connection cables in equipment
Optical fiber Secondary coating
V-…
V-…
Properties/applications
Properties/applications
Q
In equipment and distributor cabinets
Q
For splicing as pigtail
as two-sided pre-assembled cable
Q
As connection cables in equipment
Resistant to temperature fluctuations High resistance to external mechanical
Q
High flexibility Very good kink resistance Ease of installation and assembly
and distribution cabinets
Q
Q
High flexibility
Q
Q
Very good kink resistance
loads such as bending or transverse
Q
Q
Longitudinally waterproof due
pressures and environmental influ-
Q
to gel filling Q
Available without gel filling
Q
for pigtails (STB900)
09
STB900H – semi-tight buffered fiber
Q
Ease of installation and assembly (2000 mm and more can be stripped
ences
(1500 mm and more can be stripped
Easy stripping
in one piece)
(up to 80 mm in one piece) Q
and distribution cabinets
Q
Ease of installation,
Primary and secondary coating available in 12 colours
because of no gel filling
in one piece) Q
Primary and secondary coating available in 12 colours
Thermal properties transport and storage –20 °C to + 50 °C installation
+5 °C to + 40 °C
operating temperature –10 °C to + 60 °C Further basic information on cables: Chapter 12 | Principles £ page 378 ff.
Mechanical properties min. mechanical properties
30 mm
max. pull force long-term
5N
max. crush-resistance, long-term 200 N
www.leoni-fiber-optics.com