FiberConnect®
FiberTech ®
FiberSwitch ®
FiberSplit®
Fiber optic cables with UL approval
273
Outer jacket Strain relief elements STB900H semi-tight buffered fiber
Fiber optic cables (SM / MM)
FiberConnect® Simplex indoor cable
I-V(ZN)H 1… UL OFNR Order no.
84 950 40 7 Q
Standardisation
IEC 60794-2
Description
Mechanical properties
Indoor cable with UL approbation type OFNR (Riser) for USA
outer diameter
2.9 mm
and Canada. Ideal for use in distribution systems as well as for
Cable weight
10.0 kg/km
connecting terminals.
Min. bending radius static
30 mm
Composition
Max. pull force
400 N
Max. crush resistance
150 N/dm
dynamic Cable core
Flame-retardant semi-tight buffered fiber
60 mm
(STB900H) Strain relief
Non-metallic (aramid)
Fire performance
Cable jacket
Halogen-free, flame-retardant material
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
Colour of jacket
O blue
Smoke density
IEC 61034
Absence of halogen IEC 60754-1 Acidity of combus-
Thermal properties Transport/storage
– 25 °C to + 70 °C
tion gases
Installation
– 5 °C to + 50 °C
Fire load
Operating tempe-
– 10 °C to + 70 °C
rature
www.leoni-fiber-optics.com
IEC 60754-2 0.18 MJ/m
09 Approval (UL approbation type) Q
OFNR FT4 (NEC Article 770, UL 1651)
Q
c(UL)us
274
Fiber optic cables with UL approval
Fiber optic cables (SM / MM)
FiberConnect® Duplex indoor cable
Outer jacket Strain relief elements Tight buffered of semi-tight buffered fiber
I-V(ZN)H 2×1 UL OFNR Order no.
84 005 01 7 Q ZUL00
Standardisation
IEC 60794-2
Description
Thermal properties
Indoor cable approbation type OFNR (Riser) for USA and Canada.
Transport/storage
– 25 °C to + 70 °C
Ideal for use in distribution systems as well as for connecting
Installation
– 5 °C to + 50 °C
terminals.
Operating tempe-
– 10 °C to + 70 °C
rature Mechanical properties
Composition 2 flame-retardant semi-tight buffered
Outer dimensions
fibers
Cable weight
15.8 kg/km
Strain relief
Non-metallic (aramid)
Min. bending radius static
30 mm
Cable jacket
Halogen-free, flame-retardant material
Colour of jacket
O blue
Cable core
2.8 mm × 5.7 mm
dynamic
60 mm
Max. pull force
600 N
Max. crush resistance
600 N/dm
Fire performance
09
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
Smoke density
IEC 61034
Absence of halogen IEC 60754-1 Acidity of combus-
IEC 60754-2
tion gases Fire load
0.36 MJ/m
Approval (UL approbation type) Q
OFNR FT4 (NEC Article 770, UL 1651)
Q
c(UL)us
www.leoni-fiber-optics.com
FiberConnect®
FiberTech ®
FiberSwitch ®
FiberSplit®
Fiber optic cables with UL approval
275
Outer jacket Strain relief elements STB900 semi-tight buffered fiber
Fiber optic cables (SM / MM)
FiberConnect® Duplex indoor cable
Subcable jacket Rip cord
I-V(ZN)H 1… UL OFNR Order no.
84 011 01 1 Q ZUL00
Standardisation
IEC 60794-2
Description
Mechanical properties
Indoor cable with UL approbation type OFNR (Riser). Ideal for
Outer dimensions
3.7 × 6.2 mm
use in distribution systems, for connecting terminals as well as
Cable weight
26.0 kg/km
for fixed installation.
Min. bending radius static
35 mm
Composition
Max. pull force
600 N
Max. crush resistance
600 N/dm
(over flat side) Cable core
Two single-fiber cables (STB900)
dynamic
65 mm
arranged in parallel beside each other with non-metallic strain relief elements
Fire performance
(aramid)
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
and a halogen-free, flame-retardant
Smoke density
IEC 61034
subcable jacket (Ø 2.5 mm)
Absence of halogen IEC 60754-1
Cable jacket
Halogen-free, flame-retardant material
Acidity of combus-
Colour of jacket
O orange for multimode
tion gases
O yellow for singlemode
Fire load
IEC 60754-2 0.65 MJ/m
09
Thermal properties
Approval (UL approbation type)
Transport/storage
– 25 °C to + 70 °C
Installation
– 5 °C to + 50 °C
Operating tempe-
– 10 °C to + 70 °C
rature
www.leoni-fiber-optics.com
OFNR (NEC Article 770, UL 1651)
276
Fiber optic cables with UL approval
Fiber optic cables (SM / MM)
FiberConnect® Duplex indoor cable
Outer jacket Strain relief elements STB900H semi-tight buffered fiber Subcable jacket Rip cord
I-V(ZN)HH 2×1 UL OFN Order no.
84 950 50 0 Q
Standardisation
IEC 60794-2
Description
Mechanical properties
Indoor cable with UL approbation type OFN (General Purpose)
Outer dimensions
3.0 × 5.0 mm
for USA and Canada. Ideal for use in distribution systems, for
Cable weight
18.5 kg/km
connecting terminals as well as for fixed installation.
Min. bending radius static
30 mm
Composition
Max. pull force
600 N
Max. crush resistance
1000 N/dm
dynamic Cable core
Two single-fiber cables STB900H
60 mm
arranged in parallel beside each other with non-metallic strain relief elements
Fire performance
(aramid) and a halogen-free, flame-retar-
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
dant subcable jacket (Ø 2.0 mm)
Smoke density
IEC 61034
Cable jacket
Halogen-free, flame-retardant material
Absence of halogen IEC 60754-1
Colour of jacket
O orange for multimode
Acidity of combus-
O yellow for singlemode
tion gases Fire load
IEC 60754-2 0.62 MJ/m
Thermal properties
09
Transport/storage
– 25 °C to + 70 °C
Approval (UL approbation type)
Installation
– 5 °C to + 50 °C
Q
OFN FT1 75 °C (NEC Article 770, UL 1651)
Operating tempe-
– 10 °C to + 70 °C
Q
c(UL)us
rature
www.leoni-fiber-optics.com
FiberConnect®
FiberTech ®
FiberSwitch ®
FiberSplit®
Fiber optic cables with UL approval
277
Outer jacket Fleece Dummy element
Fiber optic cables (SM / MM)
FiberConnect® Duplex outdoor cable
Tight buffered fiber Strain relief elements
AT-V(ZN)YY 2… UL OFNR Order no.
84 950 63 2 Q
Standardisation
IEC 60794-2
Description
Mechanical properties
Extremely temperature-stable and UV-hard outdoor cable,
outer diameter
7.0 mm
tested according to UL OFNR flame test. Ideal for use in harsh
Weight
44.0 kg/km
environments such as mobile base stations.
Min. bending radius static
70 mm
Composition
Max. pull force
600 N
Max. crush resistance
800 N/dm
(over flat side) Cable core
Stranding consisting of two PVC single
dynamic
105 mm
cables with tight buffered fibers (TB900L) with non-metallic strain relief elements
Fire performance
(aramid) (Ø 2.4 mm)
Flame retardancy
Cable jacket
Flame-retardant polyvinyl chloride (PVC)
Colour of jacket
O black
Thermal properties Transport/storage
– 55 °C to + 85 °C
Installation
– 20 °C to + 60 °C
Operating tempe-
– 40 °C to + 85 °C
rature
www.leoni-fiber-optics.com
IEC 60332-1-2
Approval (UL approbation type) Q
OFNR FT4 (NEC Article 770, UL 1651)
Q
c(UL)us
09
278
Fiber optic cables with UL approval
Fiber optic cables (SM / MM)
FiberConnect® Duplex outdoor cable
Outer jacket Dummy element Tight buffered fiber Rip cord Strain relief elements
AT-V(ZN)YY 2… UL AWM Style Order no.
84 950 50 4 Q
Standardisation
IEC 60794-2
Description
Thermal properties
Extremely temperature-stable and UV-hard outdoor cable,
Transport/storage
– 55 °C to + 85 °C
tested acc. to UL VW-1 flame test. Ideal for use in harsh environ-
Installation
– 20 °C to + 60 °C
ments such as mobile base stations.
Operating tempe-
– 40 °C to + 85 °C
rature Mechanical properties
Composition Cable core
Stranding consisting of two PVC single ele-
outer diameter
ments with tight buffered fibers (TB900A)
7.0 mm
Weight
44.0 kg/km
with non-metallic strain relief elements
Min. bending radius static
70 mm 105 mm
(aramid) (Ø 2.4 mm)
(over flat side)
Cable jacket
Flame-retardant polyvinyl chloride (PVC)
Max. pull force
800 N
Colour of jacket
O black
Max. crush resistance
800 N/dm
dynamic
Fire performance Flame retardancy
IEC 60332-1-2 and VW-1 flame test
09 Approval (UL approbation type) UL-AWM Style 5432
www.leoni-fiber-optics.com
FiberConnect®
FiberTech ®
FiberSwitch ®
FiberSplit®
Fiber optic cables with UL approval
279
PVC Outer jacket Fleece wrapping Rip cord GFR strength member
Fiber optic cables (SM / MM)
FiberConnect® Splittable outdoor cable
PVC subcable jacket Buffered optical fiber Strain relief elements
AT-V(ZN)YY n… UL OFNR Order no.
84 217 Q Q Q Q
Standardisation
IEC 60794-2
Description
Mechanical properties
Extremely temperature-stable and UV resistant outdoor cable,
Min. bending radius static dynamic
tested acc. to UL OFNR flame test. Ideal for use in harsh environments such as mobile base stations and wind turbines.
Max. crush resistance
10 × outer diameter 15 × outer diameter 1000 N/dm
For direct connector assembly. Fire performance Composition
Q
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
GFR strength member in the core, over
Q
OFNR FT4 (NEC Article 770, UL 1651)
that single elements stranded in one layer.
Q
c(UL)us
Flame retardancy
Cable core
Single element (TB900L) made from PVC (Ø 2.2 mm). Orange colour for multimode
Approval (UL approbation type)
and yellow for singlemode and non-me-
Q
OFNR FT4 (NEC Article 770, UL 1651)
tallic strain relief elements (aramid).
Q
c(UL)us
Cable jacket
Flame-retardant polyvinyl chloride (PVC)
Colour of jacket
O black
Chemical properties
Thermal properties Transport/storage
–40 °C to + 85 °C
Installation
– 5 °C to + 50 °C
Operating tempe-
– 40 °C to + 85 °C
2 4 6 8 10 12
Outer Ø
Wall thickness
Weight
max. Pull force
mm
mm
kg/km
N
7.8 7.8 9.2 10.5 11.9 13.3
1.2 1.2 1.2 1.2 1.2 1.2
60 60 85 110 140 180
www.leoni-fiber-optics.com
Good resistance to oil, petrol, acids and alkaline solutions
Q
UV resistance of outer jacket acc. to DIN EN ISO 4892-2, test method A, UV applications up to 500 hours
rature
Max. number of fibers
Q
800 800 1200 1200 1200 1200
09
280
Fiber optic cables with UL approval
Fiber optic cables (SM / MM)
FiberConnect® Splittable outdoor cable
PVC outer jacket Strain relief elements Fleece wrapping Rip cord GFR strengh member PVC subcable jacket Buffered optical fiber Strain relief elements
AT-V(ZN)Y(ZN)Y n … UL OFNR Order no.
84 218 Q Q Q Q
Standardisation
IEC 60794-2
Description
Mechanical properties
Extremely temperature-stable and UV-resistant outdoor cable,
Min. bending radius static dynamic
tested acc. to UL OFNR flame test. Ideal for use in harsh environments such as mobile base stations and wind turbines.
Max. crush resistance
10 × outer diameter 15 × outer diameter 2000 N/dm
For direct connector assembly. Fire performance Composition
Q
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
GFR strength member in the core, over
Q
OFNR FT4 (NEC Article 770, UL 1651)
that single elements stranded in one layer.
Q
c(UL)us
Flame retardancy
Cable core
Single element (TB900L) made from PVC
09
(Ø 2.2 mm), orange colour for multimode
Approval (UL approbation type)
and yellow for singlemode and non-
Q
Type OFNR FT4 (NEC Article 770, UL 1651)
metallic strain relief elements (aramid)
Q
c(UL)us
Cable jacket
Flame-retardant polyvinyl chloride (PVC)
Colour of jacket
O black
Chemical properties
Thermal properties Transport/storage
–40 °C to + 85 °C
Installation
– 5 °C to + 50 °C
Operating tempe-
– 40 °C to + 85 °C
Q
Good resistance to oil, petrol, acids and alkaline solutions
Q
UV-hardness of outer jacket acc. to DIN EN ISO 4892-2, test method A, UV applications up to 500 hours
rature
Max. number of fibers
2 4 6 8 10 12
Outer--Ø
Wall thickness
Weight
Max. pull force
mm
mm
kg/km
N
8.4 8.4 10.1 11.4 12.8 14.2
1.2 1.2 1.2 1.2 1.2 1.2
70 70 95 120 150 190
2000 2000 3000 3000 3000 3000 www.leoni-fiber-optics.com
FiberConnect®
FiberTech ®
FiberSwitch ®
FiberSplit®
Fiber optic cables with UL approval
281
FiberConnect® Splittable outdoor cable
FRNC outer jacket Fleece wrapping Rip cord GFR strength member
Fiber optic cables (SM / MM)
Breakout cable for wind turbines
FRNC subcable jacket Buffered optical fiber Strain relief elements
AT-V(ZN)HH n… TB900L Order no.
84 222 Q Q Q Q
Standardisation
IEC 60794-2
Description
Thermal properties
Developed especially for data transmission between control
Transport/storage
–40 °C to + 70 °C
cabinets in wind power plants.
Installation
– 25 °C to + 50 °C
For flexible use in the revolving cable harness
Operating tempe-
– 40 °C to + 70 °C
in wind power plants
rature
Q
UL OFNR flame test
Mechanical properties
Q
Ideal for use in wind turbines
Min. bending radius static
Q
For direct connector assembly
Q
dynamic Torsion
Composition Cable core
10 × outer diameter 15 × outer diameter
IEC60794-1-2 E7 2000 cycles, rotation ±144°/m
GRF strength member in the core, over
Max. crush resistance
1000 N/dm
that single elements stranded in one layer.
Cable jacket
Single element (TB900L) from flame-
Fire performance
retardant FRNC (Ø 2,2 mm), orange colour
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-24 Cat. C
for multimode and yellow for singlemode
Smoke density
IEC 61034
and non-metallic strain relief elements
Absence of halogen IEC 60754-1
(aramid)
Acidity of combus-
Halogen-free, flame-retardant and
tion gases
IEC 60754-2
oil-resistant material (FRNC) Colour of jacket
O black
Approval (UL approbation type) Q
UL 1651 OFNR (UL 1666) (NEC Article 770)
Chemical properties Q
Number of fibers
2 4 6 8 10 12
Outer Ø
Weight
Pull force
mm
kg/km
N
7.8 7.8 9.2 10.5 11.9 13.3
63 63 90 110 140 189
www.leoni-fiber-optics.com
800 800 1200 1200 1200 1200
Very good resistance to oil, grease, acids and alkaline solutions
Q
Resistance of outer jackets to media and oil acc. to VG 95218-30 type B
09