Outdoor cables

FiberConnect® Universal cable with functional integrity 90 min

Fiber optic cables (SM / MM)

rodent protected , with central multi-fiber loose tube (2500 N)

Outer jacket Loose tube, gel-filled Rip cord inner fire protection tape Strain relief elements and rodent protection/outer fire protection tape

Functional integrity in the event of fire

U-D(ZN)BH n…FS Order no.

84 040 Q Q Q Q

Standardisation

IEC 60794-2

for at least 90 minutes

Description

Mechanical properties

Non-metallic, light and flexible cable with increased tensile

Min. bending radius static dynamic

strength that can be used both inside and outside buildings. Installation in cable ducts, on cable trays or in cable conduits.

15 × outer diameter 20 × outer diameter

Max. pull force on jacket

2500 N

Max. crush resistance

3000 N/dm

Composition Cable core

Loose tube, gel-filled

Fire performance

inner fire protection tape

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Multifunctional reinforced glass rovings,

Smoke density

IEC 61034

moisture blocking, as non-metallic strain

Absence of halogen IEC 60754-1

relief elements and rodent protection

Acidity of combus-

Cable jacket

Halogen-free, flame-retardant material

tion gases

Colour of jacket

O blue

Armour

IEC 60754-2

Functional integrity test Acc. to IEC 60 331-11, IEC 60 331-25 and EN 50200

Thermal properties

09

Transport/storage

– 25 °C to + 70 °C

Installation

– 5 °C to + 50 °C

Operating tempe-

– 20 °C to + 60 °C

90 min (VDE test report).

rature

Max. number of fibers

12 24

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

10.3 10.8

115 125

1.03 1.28

www.leoni-fiber-optics.com


FiberConnect®

FiberTech ®

FiberSwitch ®

FiberSplit®

Outdoor cables

233

FiberConnect® Universal cable with functional integrity 120 min

Rip cord Outer jacket Corrugated steel conduit Inner jacket Loose tube, gel filled

Fiber optic cables (SM / MM)

rodent protected and transversely waterproof , with central multi-fiber loose tube (2500 N)

inner fire barrier Strain relief elements

Functional integrity in the event of fire

U-DQ(ZN)H(SR)H n… FS Order no.

84 047 Q Q Q Q

Standardisation

IEC 60794-2

for at least 120 minutes

Description

Mechanical properties

Mechanically rugged cable with increased tensile strength

Min. bending radius static dynamic

that can be used both inside and outside buildings. Installation in cable ducts, on cable trays or in cable conduits.

15 × outer diameter 20 × outer diameter

Max. pull force on jacket

2500 N

Max. crush resistance

2500 N/dm

Composition Cable core

Loose tube,

Fire performance

gel-filled inner fire barrier

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Non-metallic (glass rovings),

Smoke density

IEC 61034

moisture blocking

Absence of halogen IEC 60754-1

Inner jacket

Halogen-free and flame-retardant

Acidity of combus-

Corrugated

as fire barrier and

tion gases

steel conduit

rodent protection

Outer jacket

Halogen-free, flame-retardant material

Functional integrity test

Colour of jacket

O blue

Acc. to IEC 60 331-11, IEC 60 331-25 and EN 50200

Strain relief

IEC 60754-2

120 min (VDE test report). Thermal properties Transport/storage

– 25 °C to + 70 °C

Installation

– 5 °C to + 50 °C

Operating tempe-

– 20 °C to + 60 °C

rature

Max. number of fibers

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

12 24

12.5 12.5

215 215

2.8 2.8

www.leoni-fiber-optics.com

09


234

Outdoor cables

FiberConnect® Universal cable with stranded tight buffered fibers

Fiber optic cables (SM / MM)

rodent-protected

Outer jacket Rip cord Tight buffered or semi-tight buffered fiber Swelling tape GFR central strength member Strain relief elements and rodent protection

U-VQ(ZN)BH n… 84 Q Q Q Q Q Q Q Order no.

with UV-resistant FRNC material:

84 045 Q Q Q Q Standardisation

IEC 60794-2

Description

Thermal properties

Cable for use inside and outside buildings. Installation in cable

Transport/storage

– 25 °C to + 70 °C

ducts, on cable trays or in cable conduits. Non-metallic universal

Installation

– 5 °C to + 50 °C

cable for direct connector assembly.

Operating tempe-

– 20 °C to + 60 °C

Suitable for all types of installation in protective conduits.

rature Mechanical properties

Composition Cable core

Min. bending radius static GFR central strength member with

dynamic

15 × outer diameter 20 × outer diameter

stranding elements, designed as tight

Max. pull force on jacket

2500 N

buffered (TB) or semi-tight buffered

Max. crush resistance

1000 N/dm

(STB) fiber and, if applicable, dummy elements.

Fire performance

Multifunctional reinforced glass rovings

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

moisture-blocking as non-metallic strain

Smoke density

IEC 61034

relief elements and rodent protection

Absence of halogen IEC 60754-1

Cable jacket

Halogen-free, flame-retardant material

Acidity of combus-

Colour of jacket

O yellow

tion gases

Armour

09

Number of fibers

4 6 8 10 12 16 20 24

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

130 130 130 145 145 150 150 155

1.03 1.03 1.03 1.21 1.21 1.37 1.37 1.44

9.4 9.4 9.4 9.8 9.8 10.8 10.8 11.1

IEC 60754-2

Order no. TB

84950890 Q 84950251Q 84950891Q 84950892Q 84950893Q 84950906Q 84950895Q 84950896Q

TB900L TB900L TB900L TB900L TB900L TB900L TB900L TB900L

Order no. STB

84950495Q 84950910Q 84950712Q 84950911Q 84950522Q 84950912Q 84950913Q 84950914Q

STB900 STB900 STB900 STB900 STB900 STB900 STB900 STB900

www.leoni-fiber-optics.com


FiberConnect®

FiberTech ®

FiberSwitch ®

FiberSplit®

Outdoor cables

235

Outer jacket Out Str Strain relief elements and rodent protection

Fiber optic cables (SM / MM)

FiberConnect® Universal cable with central multi-fiber loose tube (1750 N) rodent-protected

Loose tube, gel-filled Loo

U-DQ(ZN)BH n… 1750 N 84 025 Q Q Q Q with UV resistant FRNC material:

84 043 Q Q Q Q

Order no.

with material suited for direct burial:

84 068 Q Q Q Q Standardisation

IEC 60794-2

Description

Thermal properties

Non-metallic, light and flexible cable that can be used both

Transport/storage

– 25 °C to + 70 °C

inside and outside buildings. Installation in cable ducts, on cable

Installation

– 5 °C to + 50 °C

trays or in cable conduits.

Operating tempe-

– 20 °C to + 60 °C

rature Composition

Mechanical properties

Cable core

L oose tube, gel-filled

Armour

Multifunctional glass rovings, moisture

Min. bending radius static dynamic

15 × outer diameter 20 × outer diameter

blocking as non-metallic strain relief

Max. pull force on jacket

1750 N

elements and rodent protection

Max. crush resistance

1500 N/dm

Cable jacket

Halogen-free, flame-retardant material

Colour of jacket

O yellow

Fire performance Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. C

Smoke density

IEC 61034

Absence of halogen IEC 60754-1 Acidity of combustion gases

Max. number of fibers

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

12 24

7.0 7.5

55 60

0.71 0.79

www.leoni-fiber-optics.com

IEC 60754-2

09


236

Outdoor cables

Fiber optic cables (SM / MM)

FiberConnect® Universal cable with central multi-fiber loose tube (2500 N) rodent-protected

Outer jacket Rip cord Strain relief elements and rodent protection L oose tube, gel-filled

U-DQ(ZN)BH n… 2500 N 84 032 Q Q Q Q with UV resistant FRNC material:

Order no.

84 076 Q Q Q Q with material suited for direct burial:

84 052 Q Q Q Q Standardisation

IEC 60794-2

Description

Thermal properties

Non-metallic, light and flexible cable with increased tensile

Transport/storage

– 25 °C to + 70 °C

strength that can be used both inside and outside buildings.

Installation

– 5 °C to + 50 °C

Installation in cable ducts, on cable trays or in cable conduits.

Operating tempe-

– 20 °C to + 60 °C

rature Composition Cable core Armour

Loose tube, gel-filled

Mechanical properties

multifunctional, reinforced glass rovings,

Min. bending radius static

moisture blocking as non-metallic strain

dynamic

15 × outer diameter 20 × outer diameter

relief elements and rodent - protection

Max. pull force on jacket

2500 N

Cable jacket

Halogen-free, flame-retardant material

Max. crush resistance

3000 N/dm

Colour of jacket

O yellow

09

Fire performance Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Smoke density

IEC 61034

Absence of halogen IEC 60754-1 Max. number of fibers

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

12 24

9.2 9.7

100 110

1.25 1.34

Acidity of combus-

IEC 60754-2

tion gases

www.leoni-fiber-optics.com


FiberConnect®

FiberTech ®

FiberSwitch ®

FiberSplit®

Outdoor cables

237

Outer jacket Rip cord GFR strength member

Fiber optic cables (SM / MM)

FiberConnect® Universal cable with stranded multi-fiber loose tubes

L oose tube, gel-filled Taping

U-DH n×m… 84 029 Q Q Q Q Order no.

with UV resistant FRNC material:

84 049 Q Q Q Q Standardisation

IEC 60794-2

Description

Thermal properties

Non-metallic cable, can be used both inside and outside build-

Transport/storage

– 40 °C to + 70 °C

ings. Installation in cable ducts, on cable trays or in cable con-

Installation

– 5 °C to + 50 °C

duits.

Operating tempe-

– 40 °C to + 60 °C

rature Composition Cable core

GFR strength members with stranding

Mechanical properties

elements, designed as loose tubes and,

Min. bending radius static

if applicable, dummy elements

dynamic

15 × outer diameter 20 × outer diameter

Cable jacket

Halogen-free, flame-retardant material

Max. pull force on jacket

1500 N

Colour of jacket

O yellow

Max. crush resistance

2000 N/dm

Fire performance Flame retardancy

IEC 60332-1-2

Smoke density

IEC 61034

Absence of halogen IEC 60754-1 Acidity of combustion gases Number of tubes

1×m 2×m 3×m 4×m 5×m 6×m 8×m

Max. number of fibers

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

12 24 36 48 60 72 96

10.5 10.5 10.5 10.5 10.5 11.0 12.4

105 105 105 105 105 125 145

2.2 2.2 2.2 2.2 2.2 2.6 3.0

www.leoni-fiber-optics.com

IEC 60754-2

09


238

Outdoor cables

Fiber optic cables (SM / MM)

FiberConnect® Universal cable with stranded multi-fiber loose tubes rodent-protected

Strain relief elements and rodent protection Outer jacket Rip cord GFR strength member Loose tube, gel-filled Swelling tape

U-DQ(ZN)BH n×m… 84 033 Q Q Q Q with UV resistant FRNC material:

84 044 Q Q Q Q

Order no.

with material suited for direct burial:

84 055 Q Q Q Q Standardisation

IEC 60794-2

Description

Thermal properties

Non-metallic cable, can be used both inside and outside build-

Transport/storage

– 40 °C to + 70 °C

ings. Installation in cable ducts, on cable trays or in cable con-

Installation

– 5 °C to + 50 °C

duits.

Operating tempe-

– 40 °C to + 60 °C

rature Composition

Mechanical properties

Cable core

GFR strength member with stranding

Min. bending radius static

elements, desiged as loose tubes and, if Armour

dynamic

15 × outer diameter 20 × outer diameter

appliccable, dummy elements.

Max. pull force on jacket

6000 N

multifunctional reinforced glass rovings

Max. crush resistance

3000 N/dm

moisture blocking as non-metallic strain

09

relief elements and rodent protection

Fire performance

Cable jacket

Halogen-free, flame-retardant material

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Colour of jacket

O yellow

Smoke density

IEC 61034

Absence of halogen IEC 60754-1 Acidity of combus-

IEC 60754-2

tion gases Number of tubes

1×m 2×m 3×m 4×m 5×m 6×m 8×m 10 × m 12 × m

Max. number of fibers

12 24 36 48 60 72 96 120 144

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

12.5 12.5 12.5 12.5 12.5 13.4 14.4 15.9 17.7

185 185 185 185 185 200 225 250 305

3.1 3.1 3.1 3.1 3.1 3.2 3.4 3.7 4.5

All rodent-protected universal cables with stranded multi-fiber loose tubes are also availble in designs with different pull forces. Pull force

Order no.

4000 N

84069 Q Q Q Q

6000 N

84033 Q Q Q Q

9000 N

84058 Q Q Q Q

www.leoni-fiber-optics.com


FiberConnect®

FiberTech ®

FiberSwitch ®

FiberSplit®

Outdoor cables

239

FiberConnect® Universal cable with central multi-fiber loose tube

Aluminium tape Strain relief elements and rodent protection Outer jacket Rip cord

Fiber optic cables (SM / MM)

transversely waterproof

Loose tube, gel-filled

U-DQ(ZN)(L)H n… 84 034 Q Q Q Q

Order no.

Description

Thermal properties

Can be used both inside and outside buildings. Installation in

Transport/storage

– 25 °C to + 70 °C

cable ducts, on cable trays, in cable conduits or directly in the

Installation

– 5 °C to + 50 °C

ground.

Operating tempe-

– 20 °C to + 60 °C

rature Composition Cable core

Loose tube, gel-filled

Mechanical properties

Strain relief

non-metallic (glass rovings),

Min. bending radius static dynamic

moisture blocking

15 × outer diameter 20 × outer diameter

Aluminium taping

as absolute moisture barrier

Max. pull force on jacket

2500 N

Cable jacket

Halogen-free, flame-retardant material

Max. crush resistance

1000 N/dm

Colour of jacket

O yellow Fire performance Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Smoke density

IEC 61034

Absence of halogen IEC 60754-1 Acidity of combustion gases

Max. number of fibers

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

12 24

10.8 11.3

160 165

1.50 1.57

www.leoni-fiber-optics.com

IEC 60754-2

09


240

Outdoor cables

FiberConnect® Universal cable with central multi-fiber loose tube

Fiber optic cables (SM / MM)

rodent-protected, transversely waterproof

Strain relief elements Outer jacket Corrugated steel conduit Loose tube, gel-filled Inner jacket Rip cord

U-DQ(ZN)H(SR)H n… 84 051 Q Q Q Q with UV resistant FRNC material:

Order no.

84 044 Q Q Q Q with material suited for direct burial:

84 062 Q Q Q Q

Description

Thermal properties

Can be used both inside and outside buildings. Installation in

Transport/storage

– 25 °C to + 70 °C

cable ducts, on cable trays, in cable conduits or directly in the

Installation

– 5 °C to + 50 °C

ground.

Operating tempe-

– 20 °C to + 60 °C

rature Composition Cable core

Loose tube, gel-filled

Mechanical properties

Strain relief

non-metallic (glass rovings),

Min. bending radius static dynamic

moisture blocking

15 × outer diameter 20 × outer diameter

halogen-free, flame-retardant corrugated

Max. pull force on jacket

2500 N

steel conduit

as highly effective rodent protection

Max. crush resistance

2500 N/dm

Outer jacket

Halogen-free, flame-retardant material

Colour of jacket

O yellow

Inner jacket

Fire performance

09

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Smoke density

IEC 61034

Absence of halogen IEC 60754-1 Acidity of combusMax. number of fibers

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

12 24

12.5 12.5

215 215

2.80 2.80

IEC 60754-2

tion gases

www.leoni-fiber-optics.com


FiberConnect®

FiberTech ®

FiberSwitch ®

FiberSplit®

Outdoor cables

241

FiberConnect® Universal cable with stranded multi-fiber loose tubes

Strain relief elements Outer jacket Aluminium tape GFR central strength member

Fiber optic cables (SM / MM)

transversely waterproof

Loose tube, gel-filled Swelling tape

U-DQ(ZN)(L)H n×m… 84 035 Q Q Q Q Order no.

with UV resistant FRNC material:

84 Q Q Q Q Q Q Q Description

Thermal properties

Can be used both inside and outside buildings. Installation in

Transport/storage

– 40 °C to + 70 °C

cable ducts, on cable trays, in cable conduits or directly in the

Installation

– 5 °C to + 50 °C

ground.

Operating tempe-

– 40 °C to + 60 °C

rature Composition Cable core

GFR central strength member with strand-

Mechanical properties

ing elements designed as gel-filled loose

Min. bending radius static

tubes and, if applicable, dummy elements Strain relief

dynamic

15 × outer diameter 20 × outer diameter

non-metallic (glass rovings),

Max. pull force on jacket

3000 N

moisture blocking

Max. crush resistance

1500 N/dm

Aluminium taping

as absolute moisture barrier

Cable jacket

Halogen-free, flame-retardant material

Fire performance

Colour of jacket

O yellow

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Smoke density

IEC 61034

Absence of halogen IEC 60754-1 Acidity of combustion gases

Number of tubes

Max. number of fibers

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

1×m 2×m 3×m 4×m 5×m 6×m 8×m 10 × m 12 × m

12 24 36 48 60 72 96 120 144

12.1 12.1 12.1 12.1 12.1 13.0 14.4 15.9 17.7

170 170 170 170 170 190 230 270 320

2.73 2.73 2.73 2.73 2.73 3.13 3.28 3.60 4.39

www.leoni-fiber-optics.com

IEC 60754-2

09


242

Outdoor cables

FiberConnect® Universal cable with stranded multi-fiber loose tubes

Fiber optic cables (SM / MM)

rodent-protected, transversely waterproof

Strain relief elements Outer jacket Corrugated steel conduit GFR strength member Loose tube, gel-filled Taping

U-DQ(ZN)(SR)H n×m… 84 037 Q Q Q Q Order no.

with UV resistant FRNC material:

84 046 Q Q Q Q Description

Thermal properties

Can be used both inside and outside buildings. Installation in

Transport/storage

– 40 °C to + 70 °C

cable ducts, on cable trays, in cable conduits or directly in the

Installation

– 5 °C to + 50 °C

ground.

Operating tempe-

– 40 °C to + 60 °C

rature Composition

Mechanical properties

Cable core

GFR strength members with stranding

Min. bending radius static

elements, designed as gel-filled loose Strain relief

dynamic

15 × outer diameter 20 × outer diameter

tubes and, if applicable, dummy elements

Max. pull force on jacket

3000 N

non-metallic (glass rovings),

Max. crush resistance

2000 N/dm

moisture blocking Corrugated steel

as highly effective rodent protection

conduit

Fire performance Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Cable jacket

Halogen-free, flame-retardant material

Smoke density

IEC 61034

Colour of jacket

O yellow

Absence of halogen IEC 60754-1

09

Acidity of combus- IEC 60754-2 tion gases

Number of tubes

1×m 2×m 3×m 4×m 5×m 6×m 8×m 10 × m

Max. number of fibers

12 24 36 48 60 72 96 120

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

12.7 12.7 12.7 12.7 12.7 16.5 16.5 16.5

200 200 200 200 200 305 305 305

3.45 3.45 3.45 3.45 3.45 4.05 4.05 4.05

www.leoni-fiber-optics.com


FiberConnect®

FiberTech ®

FiberSwitch ®

FiberSplit®

Outdoor cables

243

FiberConnect® Outdoor cable with stranded multi-fiber loose tubes

Outer jacket Strain relief elements Inner jacket Corrugated steel conduit GFR strength member

Fiber optic cables (SM / MM)

rodent-protected, transversely waterproof

Loose tube, gel-filled Swelling tape Rip cord

U-DQ(ZN)H(SR)H nxm… UV Order no.

84 085 Q Q Q Q

Standardisation

IEC 60794-3

Description

Thermal properties

Can be used both inside and outside buildings. Installation in

Transport/storage

– 40 °C to + 70 °C

cable ducts, on cable trays, in cable conduits or directly in the

Installation

– 5 °C to + 50 °C

ground.

Operating tempe-

– 40 °C to + 60 °C

rature Composition Cable core

Mechanical properties GFR strength member with stranding

Min. bending radius static

elements, designed as gel-filled loose

Strain relief

15 × outer diameter

dynamic

20 × outer diameter

tubes (Ø 2.4 mm) and, if applicable,

Max. pull force on jacket

4000 N

dummy elements. Swelling tape.

Max. crush resistance

3000 N/dm

non-metallic (glass rovings), moisture blocking

Fire performance

Inner jacket

Halogen-free, flame-retardant material

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Corrugated steel

as highly effective rodent protection

Smoke density

IEC 61034

conduit

Absence of halogen IEC 60754-1

Cable jacket

Halogen-free, flame-retardant material

Acidity of combus- IEC 60754-2

Colour of jacket

O yellow

tion gases

Number of tubes

09

Max. number of fibers

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

mm

mm

12 24 36 48 60 72 96 144

16.7 16.7 16.7 16.7 16.7 18.8 18.8 21.0

360 360 360 360 360 430 430 510

4.15 4.15 4.15 4.15 4.15 4.63 4.63 5.33

340 340 340 340 340 380 380 420

250 250 250 250 250 285 285 315

1×m 2×m 3×m 4×m 5×m 6×m 8×m 12 × m

www.leoni-fiber-optics.com

Min. bending radius during installation

Min. bending radius installed


244

Outdoor cables

Fiber optic cables (SM / MM)

FiberConnect® Splittable outdoor cable

FRNC-Outer jacket Fleece FRNC subcable jacket GFR strength member Strain relief tight or semi-tight buffered fiber Rip cord

AT-VQ(ZN)HH n… 2.5 Order no.

84 202 Q Q Q Q

Standardisation

IEC 60794-2

Description

Thermal properties

Splittable outdoor cable for fixed installation in cable ducts and

Transport/storage

– 25 °C to + 70 °C

conduits. Suitable for direct connector assembly.

Installation

– 5 °C to + 50 °C

Operating tempe-

– 25 °C to + 60 °C

rature

Composition Cable core

GFR strength member in the core, over

Mechanical properties

that single elements designed as tight

Min. bending radius static dynamic

buffered (TB) and semi-tight buffered (STB) fiber, gel-filled with non-metallic strain

Max. crush resistance

15 × outer diameter 20 × outer diameter 1500 N/dm

relief elements (aramid) and halogen-free, flame-retardant subcable jacket (Ø 2.5

Fire performance

mm) stranded in layers (2–24)

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Cable jacket

Halogen-free, flame-retardant material

Smoke density

IEC 61034

Colour of jacket

O black

Absence of halogen IEC 60754-1 Acidity of combus-

IEC 60754-2

tion gases

09

Number of fibers

2 4 6 8 10 12 16 18 20 24

Outer Ø

Wall thickness

Weight

Fire load

Max. pull force

mm

mm

kg/km

MJ/m

N

8.5 8.5 10.0 11.9 13.6 15.2 15.2 16.0 16.3 18.5

1.0 1.0 1.1 1.2 1.2 1.2 1.4 1.4 1.5 1.5

65 65 80 110 150 180 190 175 220 280

1.20 1.20 1.38 1.55 1.72 1.88 1.94 1.90 2.25 2.61

800 800 1200 1200 1200 1200 1200 1200 1200 1200

www.leoni-fiber-optics.com


FiberConnect®

FiberTech ®

FiberSwitch ®

FiberSplit®

Outdoor cables

245

PE outer jacket Strain relief/rodent protection Fleece FRNC subcable jacket Rip cord GFR strength member

Fiber optic cables (SM / MM)

FiberConnect® Splittable outdoor cable

Strain relief tight or semi-tight buffered fiber

AT-VQ(ZN)H(ZN)B2Y n… 2.5 Order no.

84 205 Q Q Q Q

Standardisation

IEC 60794-2

Description

Thermal properties

Splittable, transversely water resistant outdoor cable with

Transport/storage

– 25 °C to + 70 °C

non-metallic rodent protection for fixed installation indoors

Installation

– 5 °C to + 50 °C

and outdoors in cable ducts, conduits and cable trays. The

Operating tempe-

– 20 °C to + 60 °C

single cables are longitudinally waterproof. For direct connector

rature

assembly.

Mechanical properties Min. bending radius static

Composition

dynamic

Cable core

GFR strength member in the core, over

Max. crush resistance

15 × outer diameter 20 × outer diameter 1500 N/dm

that breakout single elements designed as tight buffered (TB) or semi-tight buff-

Fire performance

ered (STB)f, gel-filled with non-metallic

Absence of halogen IEC 60754-1

strain relief elements (aramid) and a halo-

Acidity of combus-

gen -free flame retardant subcable jacket

tion gases

IEC 60754-2

(Ø 2.5 mm) stranded in layers (2–24) Armour

Multifunctional reinforced glass rovings as non-metallic strain relief elements and rodent protection

Cable jacket

Polyethylene

Colour of jacket

O black

Number of fibers

Outer Ø

Wall thickness

Weight

Fire load

mm

mm

kg/km

MJ/m

N

2 4 6 8 10 12 16 20 24

10.0 10.0 11.0 13.0 14.5 16.0 16.0 18.0 19.0

1.0 1.0 1.2 1.2 1.2 1.2 1.5 1.5 1.5

85 90 115 145 175 210 215 315 360

1.20 1.20 1.38 1.55 1.72 1.88 1.94 2.25 2.61

2500 2500 3000 3000 3000 3000 3000 3000 3000

www.leoni-fiber-optics.com

max. Pull force

09


246

Outdoor cables

Fiber optic cables (SM / MM)

FiberConnect® Outdoor cable with central multi-fiber loose tube (1750 N) rodent-protected

Outer jacket Loose tube, gel-filled Strain relief elements and rodent protection

A-DQ(ZN)B2Y n… 1750 N Order no.

84 305 Q Q Q Q

Standardisation

IEC 60794-3

Description

Mechanical properties

Light, flexible and non-metallic outdoor cable for primary cab-

Min. bending radius static dynamic

ling and the backbone area. For pulling into conduits, installation on cable trays or directly in the ground.

15 × outer diameter 20 × outer diameter

Max. pull force

1750 N

Max. crush resistance

1500 N/dm

Composition Cable core Armour

Loose tube, gel-filled

Fire performance

multifunctional glass rovings,

Absence of halogen IEC 60754-1

moisture blocking as strain relief and

Acidity of combus-

rodent protection

tion gases

Cable jacket

Polyethylene

Colour of jacket

O black

IEC 60754-2

Note The Polyethylene jacket offers good protection against transversal water ingress.

Thermal properties

09

Transport/storage

– 25 °C to + 70 °C

Installation

– 5 °C to + 50 °C

Operating tempe-

– 20 °C to + 60 °C

rature

Max. number of fibers

12 24

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

7.0 7.5

42 47

1.10 1.20

www.leoni-fiber-optics.com


FiberConnect®

FiberTech ®

FiberSwitch ®

FiberSplit®

Outdoor cables

247

Outer jacket Loose tube, gel-filled

Fiber optic cables (SM / MM)

FiberConnect® Direct buried cable

Strain relief elements

A-DQ(ZN)2Y n… 1750 N ZB Order no.

84 375 Q Q Q Q

Standardisation

IEC 60794-3

Description

Thermal properties

Light, flexible and non-metallic outdoor cable for primary

Transport/storage

– 40 °C to + 70 °C

cabling and the backbone area. For pulling into contduits, instal-

Installation

– 5 °C to + 50 °C

lation on cable trays or directly in the ground.

Operating tempe-

– 40 °C to + 60 °C

rature Mechanical properties

Composition Cable core

Min. bending radius static

Two-layer loose tube, gel-filled,

dynamic

diameter 3.5 mm ( up o 12 fibers),

15 × outer diameter 20 × outer diameter

4.0 mm (to 24 fibers)

Max. pull force

1750 N

Colour: yellow (E9/125), green (G50/125)

Max. crush resistance

2000 N/dm

and blue (G62.5/125). Strain relief

Non-metallic (aramid)

Fire performance

Cable jacket

Polyethylene

Absence of halogen IEC 60754-1

Colour of jacket

O black

Acidity of combus-

IEC 60754-2

tion gases

09

Max. number of fibers

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

7.0 7.5

37 42

1.5 1.7

12 24

www.leoni-fiber-optics.com


248

Outdoor cables

Fiber optic cables (SM / MM)

FiberConnect® Outdoor cable with central multi-fiber loose tube (2500 N) rodent-protected

Outer jacket n ds a Withsta of e rc pull fo

25 u p to

Rip cord Loose tube, gel-filled

00 N

Strain relief elements and rodent protection

A-DQ(ZN)B2Y n… 2500 N Order no.

84 321 Q Q Q Q

Standardisation

IEC 60794-3

Description

Mechanical properties

Non-metallic construction for primary cabling and the back-

Min. bending radius static dynamic

bone area. For pulling into conduits, installation on cable trays or directly in the ground.

15 × outer diameter 20 × outer diameter

Max. pull force

2500 N

Max. crush resistance

3000 N/dm

Composition Cable core Armour

Loose tube, gel-filled

Fire performance

multifunctional reinforced glass rovings,

Absence of halogen IEC 60754-1

moisture blocking as strain relief and

Acidity of combus-

rodent protection

tion gases

Cable jacket

Polyethylene with imprint

Colour of jacket

O black

IEC 60754-2

Note The Polyethylene jacket offers good protection against transversal water ingress.

Thermal properties

09

Transport/storage

– 25 °C to + 70 °C

Installation

– 5 °C to + 50 °C

Operating tempe-

– 20 °C to + 60 °C

rature

Max. number of fibers

12 24

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

9.2 9.7

76 81

1.90 2.00

www.leoni-fiber-optics.com


FiberConnect®

FiberTech ®

FiberSwitch ®

FiberSplit®

Outdoor cables

249

FiberConnect® Outdoor cable with stranded multi-fiber loose tubes

Outer jacket Swelling tape Rip cord Loose tube, gel-filled

Fiber optic cables (SM / MM)

rodent-protected, dry core

Strain relief elements and rodent protection GFR strength member

A-DQ(ZN)B2Y n×m… Order no.

84 316 Q Q Q Q

Standardisation

IEC 60794-3

Description

Thermal properties

Non-metallic, rugged outdoor cable. Installation-friendly

Transport/storage

– 40 °C to + 70 °C

because of the grease-free cable core. Installation in conduits,

Installation

– 5 °C to + 50 °C

on cable trays and directly in the ground.

Operating tempe-

– 40 °C to + 60 °C

rature Composition

Mechanical properties GFR strength member with stranding ele-

Cable core

Min. bending radius static

ments designed as gel-filled loose tubes and, Armour

dynamic

15 × outer diameter 20 × outer diameter

if applicable, dummy elements

Max. pull force

4000 N

multifunctional reinforced glass rovings

Max. crush resistance

3000 N/dm

as non-metallic strain relief elements and rodent protection

Fire performance

Cable jacket

Polyethylene with hot stamped marking

Absence of halogen IEC 60754-1

Colour of jacket

O black

Acidity of combus-

IEC 60754-2

tion gases

09 Note Q

The Polyethylene jacket offers good protection against transversal water ingress

Number of tubes

Max. number of fibers

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

1×m 2×m 3×m 4×m 5×m 6×m 8×m 10 × m 12 × m 16 × m 24 × m

12 24 36 48 60 72 96 120 144 192 288

11.4 11.4 11.4 11.4 11.4 12.3 13.7 15.2 17.0 17.3 20.2

115 115 115 115 115 135 160 190 230 240 320

4.1 4.1 4.1 4.1 4.1 4.5 5.0 5.5 6.2 6.2 6.2

www.leoni-fiber-optics.com

Q

Higher fiber counts and pull forces on request

Q

Also available with aluminium layer or corrugated steel jacket.

All rodent-protected universal cables with stranded multi-fiber loose tubes are also available with different pull forces. Pull force

Order no.

4000 N

84316 Q Q Q Q

6000 N

84346 Q Q Q Q

9000 N

84330 Q Q Q Q


250

Outdoor cables

FiberConnect® Outdoor cable with stranded multi-fiber loose tubes

Fiber optic cables (SM / MM)

grease-filled

Outer jacket Swelling tape Loose tube, gel-filled Core filling Strain relief elements GFR strength member

A-DF(ZN)2Y n×m… Order no.

84 300 Q Q Q Q

Standardisation

IEC 60794-3

Description

Thermal properties

Non-metallic cable for primary cabling and the backbone area.

Transport/storage

– 40 °C to + 70 °C

For pulling into conduits, installation on cable trays or directly in

Installation

– 5 °C to + 50 °C

the ground.

Operating tempe-

– 40 °C to + 60 °C

rature Composition Cable core

GFR strength member with stranding

Mechanical properties

elements, designed as gel-filled loose

Min. bending radius static dynamic

tubes and, if applicable, dummy elements. Cable core filled with petroleum jelly

Max. pull force

15 × outer diameter 20 × outer diameter

≤ 7 stranding element 3000 N > 7 stranding element 4000 N

Strain relief

Glass rovings

Cable jacket

Polyethylene with hot stamped marking

Colour of jacket

O black

Max. crush resistance

3000 N/dm

Fire performance Absence of halogen IEC 60754-1 Acidity of combus-

09

IEC 60754-2

tion gases Note Q

Number of tubes

1×m 2×m 3×m 4×m 5×m 6×m 8×m 10 × m 12 × m 16 × m

Max. number of fibers

12 24 36 48 60 72 96 120 144 192

Outer Ø

Weight

transversal water ingress

Fire load

mm

kg/km

MJ/m

11.4 11.4 11.4 11.4 11.4 12.3 13.7 15.2 17.0 16.8

120 120 120 120 120 135 170 200 240 255

4.3 4.3 4.3 4.3 4.3 4.6 5.1 5.7 6.5 7.4

The Polyethylene jacket offers good protection against

Q

Also available with aluminium layers, corrugated steel jacket and copper elements

www.leoni-fiber-optics.com


FiberConnect®

FiberTech ®

FiberSwitch ®

FiberSplit®

Outdoor cables

251

FiberConnect® Outdoor cable with stranded multi-fiber loose tubes

Core filling Outer jacket Corrugated steel conduit Inner jacket Rip cord

Fiber optic cables (SM / MM)

rodent-protected, grease-filled

Swelling tape Loose tube, gel-filled Strain relief elements GFR strength member

A-DF(ZN)2Y(SR)2Y n×m… Order no.

84 310 Q Q Q Q

Standardisation

IEC 60794-3

Description

Thermal properties

Rugged outdoor cable for primary cabling and the backbone

Transport/storage

– 40 °C to + 70 °C

area. For pulling into contduits, installation on cable trays or

Installation

– 5 °C to + 50 °C

directly in the ground.

Operating tempe-

– 40 °C to + 60 °C

rature Composition Cable core

GFR strength member with stranding

Mechanical properties

elements designed as gel-filled loose tubes

Min. bending radius static dynamic

and, if applicable, dummy elements. Cable core filled with petroleum jelly.

Max. pull force

Glass rovings

Inner jacket

Polyethylene, O black

Corrugated steel

as highly effective rodent protection

≤ 7 stranding elements 3000 N

Max. crush resistance

3000 N/dm

Fire performance

conduit Cable jacket

Polyethylene with hot stamped marking

Absence of halogen IEC 60754-1

Colour of jacket

O black

Acidity of combustion gases

1×m 2×m 3×m 4×m 5×m 6×m 8×m 10 × m 12 × m 16 × m

20 × outer diameter

> 7 stranding elements 4000 N

Strain relief

Number of tubes

15 × outer diameter

Max. number of fibers

12 24 36 48 60 72 96 120 144 192

www.leoni-fiber-optics.com

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

16.7 16.7 16.7 16.7 16.7 17.5 18.8 21.8 21.8 21.8

275 275 275 275 275 335 335 335 370 380

10.4 10.4 10.4 10.4 10.4 12.0 12.0 12.5 13.1 13.8

IEC 60754-2

09


252

Outdoor cables

FiberConnect® Outdoor cable with stranded multi-fiber loose tubes

Fiber optic cables (SM / MM)

rodent-protected, transversely waterproof

PE outer jacket Corrugated steel conduit PE inner jacket Rip cord Strain relief Swelling tape Loose tube GFR strength member

A-DQ(ZN)2Y(SR)2Y n×m… Order no.

84 329 Q Q Q Q

Standardisation

IEC 60794-3

Description

Thermal properties

Dry-core, longitudinally and transversely waterproof fiber optic

Transport/storage

– 40 °C to + 70 °C

outdoor cable with highly effective rodent protection. For direct

Installation

– 5 °C to + 50 °C

burial, installation in conduits, ducts or on trays, also suited for

Operating tempe-

– 40 °C to + 60 °C

vertical ladders.

rature

Suitable for all installation techniques (e. g. pulling and blowing in). Mechanical properties Composition

Min. bending radius static

Cable core

dynamic

GFR strength member with stranding elements, designed as gel-filled loose

Max. pull force

tubes (Ø 2.4 mm) and, if applicable, dummy elements

> 7 stranding elements 4000 N Max. crush resistance

1000 N/dm

Glass rovings

Inner jacket

Polyethylene

Fire performance

Corrugated steel

as highly effective rodent protection

Absence of halogen IEC 60754-1 Acidity of combus-

Cable jacket

Polyethylene with hot stamped marking

Colour of jacket

O black

Composition

Max. number of fibers

Outer Ø

Weight

Fire load

mm

kg/km

MJ/km

1×m 2×m 3×m 4×m 5×m 6×m 8×m 10 × m 12 × m

12 24 36 48 60 72 96 120 144

16.7 16.7 16.7 16.7 16.7 16.7 18.8 21.0 21.0

275 275 275 275 275 275 340 335 370

10.4 10.4 10.4 10.4 10.4 12.0 12.0 12.5 13.1

20 × outer diameter

≤ 7 stranding elements 3000 N

Strain relief

conduit

09

15 × outer diameter

IEC 60754-2

tion gases

www.leoni-fiber-optics.com


FiberConnect®

FiberTech ®

FiberSwitch ®

FiberSplit®

Outdoor cables

253

FiberConnect® Outdoor cable with central multi-fiber loose tube

Outer jacket Aluminium tape Rip cord Loose tube, gel-filled

Fiber optic cables (SM / MM)

transversely waterproof

Strain relief elements

A-DQ(ZN)(L)2Y n… Order no.

84 333 Q Q Q Q

Standardisation

IEC 60794-3

Description

Thermal properties

Light outdoor cable with diffusion barrier. Installation in cable

Transport/storage

– 25 °C to + 70 °C

ducts, on cable trays, in cable conduits or directly in the ground.

Installation

– 5 °C to + 50 °C

Operating tempe-

– 20 °C to + 60 °C

rature

Composition Cable core

Loose tube, gel-filled

Strain relief

non-metallic (glass rovings),

Mechanical properties

moisture blocking

Min. bending radius static dynamic

15 × outer diameter 20 × outer diameter

Alumimium taping

as absolute moisture barrier

Cable jacket

Polyethylene with imprint

Max. pull force

2500 N

O black

Max. crush resistance

1000 N/dm

Colour of jacket

Fire performance Absence of halogen IEC 60754-1 Acidity of combustion gases

Max. number of fibers

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

12 24

10.8 11.3

128 135

1.42 1.62

www.leoni-fiber-optics.com

IEC 60754-2

09


254

Outdoor cables

FiberConnect® Outdoor cable with central multi-fiber loose tube

Fiber optic cables (SM / MM)

rodent-protected, transversely waterproof

Outer jacket Corrugated steel conduit Inner jacket Rip cord Loose tube, gel-filled Strain relief elements

A-DQ(ZN)2Y(SR)2Y n… Order no.

84 331 Q Q Q Q

Standardisation

IEC 60794-3

Description

Thermal properties

Rugged outdoor cable for installation in cable ducts, conduits,

Transport/storage

– 40 °C to + 70 °C

on cable trays or directly in the ground.

Installation

– 5 °C to + 50 °C

Operating tempe-

– 40 °C to + 70 °C

rature

Composition Cable core

loose tube, gel-filled

Strain relief

non-metallic (glass rovings),

Mechanical properties

moisture blocking

Min. bending radius static dynamic

Inner jacket

Polyethylene, O black

Corrugated steel

as highly effective rodent protection

conduit Outer jacket

Polyethylene with imprint

Colour of jacket

O black

15 × outer diameter 20 × outer diameter

Max. pull force

2500 N

Max. crush resistance

2500 N/dm

Fire performance Absence of halogen IEC 60754-1 Acidity of combus-

IEC 60754-2

tion gases

09

Number of fibers

12 24

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

12.5 12.5

160 160

1.8 1.8

www.leoni-fiber-optics.com


FiberConnect®

FiberTech ®

FiberSwitch ®

FiberSplit®

Outdoor cables

255

FiberConnect® Outdoor cable with stranded multi-fiber loose tubes

Outer jacket Aluminium tape Rip cord Swelling tape

Fiber optic cables (SM / MM)

transversely waterproof

Loose tube, gel-filled Strain relief elements GFR strength member

A-DQ(ZN)(L)2Y n×m… Order no.

84 326 Q Q Q Q

Standardisation

IEC 60794-3

Description

Thermal properties

Rugged outdoor cable with diffusion barrier. For installation

Transport/storage

– 40 °C to + 70 °C

in cable ducts and conduits, on cable trays or directly in the

Installation

– 5 °C to + 50 °C

ground.

Operating tempe-

– 40 °C to + 60 °C

rature Composition Cable core

GFR strength member with stranding

Mechanical properties

elements, designed as gel-filled loos tubes

Min. bending radius static dynamic

and , if applicable, dummy elements Strain relief

15 × outer diameter 20 × outer diameter

Non-metallic (glass rovings),

Max. pull force

3000 N

moisture blocking

Max. crush resistance

1500 N/dm

Aluminium taping

as absolute moisture barrier

Cable jacket

Polyethylene with hot stamped marking

Fire performance

Colour of jacket

O black

Absence of halogen IEC 60754-1 Acidity of combustion gases

Number of tubes

Max. number of fibers

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

1×m 2×m 3×m 4×m 5×m 6×m 8×m 10 × m 12 × m

12 24 36 48 60 72 96 120 144

12.1 12.1 12.1 12.1 12.1 13.0 14.4 15.9 17.7

140 140 140 140 140 160 200 240 280

4.9 4.9 4.9 4.9 4.9 5.6 5.9 6.4 7.2

www.leoni-fiber-optics.com

IEC 60754-2

09


256

Outdoor cables

FiberConnect® Outdoor cable with stranded multi-fiber loose tubes

Fiber optic cables (SM / MM)

rodent-protected, transversely waterproof

Outer jacket Corrugated steel conduit Rip cord Loose tube,gel-filled Strain relief elements GFR strength member Fleece

A-DQ(ZN)(SR)2Y n×m… Order no.

84 334 Q Q Q Q

Standardisation

IEC 60794-3

Description

Thermal properties

Rugged outdoor cable for installation in cable ducts or conduits,

Transport/storage

– 40 °C to + 70 °C

on cable trays or directly in the ground.

Installation

– 5 °C to + 50 °C

Operating tempe-

– 40 °C to + 60 °C

rature

Composition Cable core

GFR strength member with stranding

Strain relief

elements, designed as gel-filled loose

Mechanical properties

tubes and , if applicable, dummy elements

Min. bending radius static dynamic

Non-metallic (glass rovings),

15 × outer diameter 20 × outer diameter

moisture blocking

Max. pull force

3000 N

as highly effective rodent protection

Max. crush resistance

2000 N/dm

Cable jacket

Polyethylene with hot stamped marking

Fire performance

Colour of jacket

O black

Absence of halogen IEC 60754-1

Corrugated steel conduit

Acidity of combus-

IEC 60754-2

tion gases

09

Number of tubes

Max. number of fibers

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

1×m 2×m 3×m 4×m 5×m

12 24 26 48 60

12.7 12.7 12.7 12.7 12.7

165 165 165 165 165

4.6 4.6 4.6 4.6 4.6

www.leoni-fiber-optics.com