Brochure glasvezelkabels voor kantoren

Page 1

222

Office cables

Fiber optic cables (SM / MM)

FiberConnect® Simplex cable

Outer jacket Strain relief elements Tight buffered or semi-tight buffered fiber

I-V(ZN)H 1… Order no.

84 QQ Q QQ Q Q

Standardisation

IEC 60794-2

Description

Thermal properties

Ideal for use as a patch cable in distribution systems as well as

Transport/storage

– 25 °C to + 70 °C

for connecting terminals due to the high flexibility and small

Installation

– 5 °C to + 50 °C

diameter.

Operating tempe-

– 10 °C to + 70 °C

rature Composition Cable core

tight buffered (TB) or semi-tight buffered

Mechanical properties

fiber (STB)

Min. bending radius static dynamic

Strain relief

Non-metallic (aramid)

Cable jacket

Halogen-free and flame-retardant

Colour of jacket

30 mm 60 mm

material

Fire performance

O orange for multimode

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

O yellow for singlemode

Smoke density

IEC 61034

£ other colours possible

Absence of halogen IEC 60754-1 Acidity of

IEC 60754-2

combustion gases

09 Outer Ø

Type

mm

1.6 1.8 2.0 2.1 2.4 2.8 3.0 3.4

Weight kg/km

I-V(ZN)H 1… I-V(ZN)H 1… I-V(ZN)H 1… I-V(ZN)H 1… I-V(ZN)H 1…* I-V(ZN)H 1… I-V(ZN)H 1… I-V(ZN)H 1…*

2.9 3.7 5.0 5.1 5.7 7.9 8.1 12.0

max. pull force long-term

max. - crush resistance long-term

Fire load

N

N/dm

MJ/m

200 200 300 300 400 400 400 400

100 100 100 100 150 150 150 150

0.09 0.10 0.11 0.12 0.16 0.18 0.21 0.32

Order no. TB

84950216 Q TB600L 84950559 Q TB900L 8404200L Q TB900L 8405600L Q TB900L 84950846 Q TB900L 8400300L Q TB900L 84950560 Q TB900L 84950770 Q TB900L

Order no. STB

84950878 Q STB600 84950212 Q STB900 84042001 Q STB900 84056001 Q STB900 84950007 Q STB900 84003001 Q STB900 84950347 Q STB900 84950194 Q STB900

* according to TS 0011/96 Deutsche Telekom

www.leoni-fiber-optics.com


FiberConnect®

FiberTech ®

FiberSwitch ®

FiberSplit®

Office cables

223

Outer jacket Strain relief elements Tight buffered or semi-tight

Fiber optic cables (SM / MM)

FiberConnect® Duplex cable

buffered fiber

I-V(ZN)H 2×1… Order no.

84 QQ Q QQ Q Q

Standardisation

IEC 60794-2

Description

Thermal properties

Ideal for use as a patch cable in distribution systems as well as

Transport/storage

– 25 °C to + 70 °C

for connecting terminals due to the high flexibility and small

Installation

– 5 °C to + 50 °C

diameter.

Operating tempe-

– 10 °C to + 70 °C

rature Composition Cable core

Tight buffered (TB) or semi-tight buffered

Mechanical properties

fiber (STB)

Min. bending radius static dynamic

30 mm 60 mm

Strain relief

Non-metallic (aramid)

Cable jacket

Halogen-free, flame-retardant material

Colour of jacket

O orange for multimode

Fire performance

O yellow for singlemode

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

£ other colours possible

Smoke density

IEC 61034

Absence of halogen IEC 60754-1 Acidity of

IEC 60754-2

combustion gases

09 Outer Ø

Type

mm

1.6 × 3.3 1.8 × 3.7 1.8 × 3.7 2.0 × 4.1 2.1 × 4.3 2.35 × 4.8 2.8 × 5.7 3.0 × 6.1

I-V(ZN)H 2×1… I-V(ZN)H 2×1… I-V(ZN)H 2×1… I-V(ZN)H 2×1… I-V(ZN)H 2×1… I-V(ZN)H 2×1… I-V(ZN)H 2×1… I-V(ZN)H 2×1…

www.leoni-fiber-optics.com

Weight

max. pull force long-term

max. - crush resistance long-term

Fire load

kg/km

N

N/dm

MJ/m

5.8 7.4 7.4 9.0 9.0 12.6 15.8 17.5

400 400 400 400 400 400 600 600

200 200 200 200 400 400 600 600

0.18 0.20 0.20 0.22 0.24 0.31 0.36 0.42

Order no. TB

84950867 Q TB600L 84950869 Q TB600L 84950875 Q TB900L 8400401L Q TB900L 84950479 Q TB900L 84950076 Q TB900L 8400501L Q TB900L 84950876 Q TB900L

Order no. STB

84950877 Q STB600 84950199 Q STB600 84950QQQQ STB900 84004011 Q STB900 84950235 Q STB900 84950253 Q STB900 84005011 Q STB900 84950250 Q STB900


224

Office cables

Fiber optic cables (SM / MM)

FiberConnect® Breakout cable, flat

Outer jacket Strain relief elements Tight buffered or semi-tight buffered fiber Subcable jacket Rip cord

I-V(ZN)HH 2×1… Order no.

84 QQ Q QQ Q Q

Standardisation

IEC 60794-2

Description

Thermal properties

Light, thin and rugged indoor cable for use as a patch cable in

Transport/storage

– 25 °C to + 70 °C

distribution systems, as connection cable for terminals as well as

Installation

– 5 °C to + 50 °C

for workstation cabling. For direct connector assembly.

Operating tempera-

– 10 °C to + 70 °C

ture Mechanical properties

Composition Cable core

Two single-fiber cables (TB or STB)

Min. bending radius

static

35 mm

arranged in parallel beside each other

(over flat side)

dynamic

65 mm

with non-metallic strain relief elements (aramid) and a halogen-free, flame-retar-

Fire performance

dant subcable jacket (Ø see table)

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Cable jacket

Halogen-free, flame-retardant material

Smoke density

IEC 61034

Colour of jacket

O orange for multimode

Absence of halogen

IEC 60754-1

O yellow for singlemode

Acidity of combusti

IEC 60754-2

on gases

09

Single element mm

1.7 1.8 2.0 2.1 2.5 2.8

Cable outer dimensions

Type

mm

2.8 × 4.5 2.9 × 4.7 3.1 × 5.2 3.1 × 5.2 3.7 × 6.2 4.0 × 6.8

I-V(ZN)HH 2×1… I-V(ZN)HH 2×1… I-V(ZN)HH 2×1… I-V(ZN)HH 2×1… I-V(ZN)HH 2×1… I-V(ZN)HH 2×1…

Weight

max. pull force long-term

max. - crush resistance long-term

Fire load

kg/km

N

N/dm

MJ/m

16.5 17.5 19.0 19.0 26.0 32.0

400 400 600 600 600 600

400 400 400 400 600 600

0.58 0.60 0.63 0.63 0.65 0.83

Order no. TB

84950881 Q 84950882 Q 84070 QQQQ 84017 QQQQ 8401101L Q 8401201L Q

TB600L TB600L TB900L TB900L TB900L TB900L

Order no. STB

84950887 Q 84950886 Q 84070 QQQQ 84017 QQQQ 84011011 Q 84012011 Q

STB600 STB600 STB900 STB900 STB900 STB900

www.leoni-fiber-optics.com


FiberConnect®

FiberTech ®

FiberSwitch ®

FiberSplit®

Office cables

225

Outer jacket Strain relief elements Tight buffered or semi-tight buffered fiber

Fiber optic cables (SM / MM)

FiberConnect® Mini breakout cable

I-V(ZN)H n… 84 026 QQ Q Q Order no.

with UV resistant FRNC material:

84 039 Q Q Q Q Standardisation

IEC 60794-2

Description

Thermal properties

Ideal for workstation cabling due to the high flexibility and

Transport/storage

– 25 °C to + 70 °C

small dimensions. Non-metallic indoor cable for direct connec-

Installation

– 5 °C to + 50 °C

tor assembly.

Operating tempe-

– 5 °C to + 70 °C

Composition

Mechanical properties

rature Cable core

Tight buffered (TB) or semi-tight

Max. pull force

800 N 500 N/dm

buffered fiber (STB)

Max. crush

Strain relief

Non-metallic (aramid)

resistance

Cable jacket

Halogen-free, flame-retardant material

Colour of jacket

O orange for multimode

Fire performance

O yellow for singlemode

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Smoke density

IEC 61034

Absence of halogen IEC 60754-1 Acidity of combus-

IEC 60754-2

tion gases

Number of fibers

2 4 6 8 12 16 24

Outer Ø

Weight

Min. bending radius static

dynamic

Fire load

All mini breakout cables available

mm

kg/km

mm

mm

MJ/m

with TB and STB fibers

4.2 5.6 5.9 6.1 7.0 8.4 9.4

14 21 25 30 38 59 72

40 55 60 60 70 85 95

65 85 90 90 95 120 135

0.45 0.47 0.50 0.52 0.55 0.74 0.92

Order no. on request

www.leoni-fiber-optics.com

09


226

Office cables

Fiber optic cables (SM / MM)

FiberConnect® Breakout cable

Outer jacket Fleece Tight buffered or semi-tight buffered fiber Central strength member Subcable jacket Strain relief elements Rip cord

I-V(ZN)HH n… Order no.

see table

Standardisation

IEC 60794-2

Description

Thermal properties

Non-metallic, rugged cable for installation in the riser and

Transport/storage

– 25 °C to + 70 °C

horizontal indoor area. For direct connector assembly.

Installation

– 5 °C to + 50 °C

Operating tempe-

– 10 °C to + 70 °C

rature

Composition Cable core

Stranded single elements designed as

Fire performance

tight buffered fiber (TB) or semi-tight

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

buffered fiber (STB) with non-metallic

Smoke density

IEC 61034

strain relief elements (aramid) and halo-

Absence of halogen IEC 60754-1

gen-free, flame-retardant subcable jacket

Acidity of

(Ø see table)

combustion gases

IEC 60754-2

Cable jacket

halogen-free, flame-retardant material

Colour of jacket

O orange for multimode

Note

O yellow for singlemode

The cable is alternatively available with non-metallic rodent protection (B).

09 Single cable with 1.8 mm Ø, buffered fiber: TB600, tight buffered fiber with Ø 600 µm Order no. 84 015 Q Q Z Q Number of fibers

2 4 6 8 10 12 16 18 20 24 48

Outer Ø

Weight

mm

kg/km

6.0 6.0 6.9 8.3 9.9 11.0 10.7 11.3 11.7 12.9 17.2

35 35 47 69 105 119 106 116 129 162 245

Min. bending radius static

Min. bending radius dynamic

mm

mm

60 60 70 85 100 110 110 115 120 130 175

85 85 105 125 150 165 160 170 180 200 260

Max. pull force long-term

Max. crush resistance long-term

Fire load

N

N/dm

MJ/m

800 800 800 800 800 800 800 800 800 800 800

0.63 0.63 0.89 1.22 2.01 2.37 2.03 2.27 2.54 3.11 5.43

600 600 800 800 800 800 1000 1000 1200 1200 1200

www.leoni-fiber-optics.com


FiberTech ®

FiberSwitch ®

FiberSplit®

Office cables

Single cable with 2.0 mm Ø, tight buffered fiber, semi-tight buffered fiber or superstrip fiber with 900 µm Order no. Number of fibers

2 4 6 8 10 12 16 18 20 24

84 054 Q Q L Q (TB900L) | 84 054 Q Q 1 Q (STB900) | 84 054 Q Q 7 Q (STB900H) Outer Ø

Weight

mm

kg/km

6.8 6.8 8.0 9.4 10.8 12.3 11.6 12.6 14.1 14.2

45 45 60 85 125 150 140 160 180 200

Min. bending radius static mm

70 70 80 95 110 125 120 130 145 150

Min. bending radius dynamic mm

105 105 120 145 165 190 180 195 220 225

Max. pull force long-term

Max. crush resistance long-term

Fire load

N

N/dm

MJ/m

1000 1000 1000 1000 1000 1000 1000 1000 1000 1000

1.08 1.08 1.15 1.28 1.39 1.54 1.56 1.88 2.07 2.23

Max. crush resistance long-term

Fire load

N/dm

MJ/m

1000 1000 1000 1000 1000 1000 1000 1000 1000 1000

1.10 1.10 1.18 1.31 1.42 1.57 1.62 2.00 2.10 2.35

800 800 1000 1000 1000 1000 1000 1000 1000 1000

227

Fiber optic cables (SM / MM)

FiberConnect®

Single cable with 2.1 mm Ø, tight buffered fiber, semi-tight buffered fiber or superstrip fiber with Ø 900 µm Order no. Number of fibers

2 4 6 8 10 12 16 18 20 24

84 013 Q Q L Q (TB900L) | 84 013 Q Q 1 Q (STB900) | 84 013 Q Q 7 Q (STB900H) Outer Ø

Weight

mm

kg/km

7.0 7.0 8.2 9.8 11.0 12.5 12.0 13.0 14.5 15.0

40 45 65 95 135 155 140 160 205 210

Min. bending radius static mm

70 70 80 95 110 125 120 130 145 150

Min. bending radius dynamic mm

105 105 120 145 165 190 180 195 220 225

Max. pull force long-term N

800 800 1000 1000 1000 1000 1000 1000 1000 1000

09 Single cable with 2.5 mm Ø, tight buffered fiber, semi-tight buffered fiber or superstrip fiber with Ø 900 µm Order no. Number of fibers

2 4 6 8 10 12 16 18 20 24

84 010 Q Q L Q (TB900L) | 84 010 Q Q 1 Q (STB900) | 84 010 Q Q 7 Q (STB900H) Outer Ø

Weight

mm

kg/km

7.5 7.5 9.0 11.0 13.0 14.5 14.0 14.5 16.0 17.0

www.leoni-fiber-optics.com

45 50 75 110 160 182 160 175 225 245

Min. bending radius static mm

75 75 90 110 130 145 140 145 160 175

Min. bending radius dynamic

Max. pull force long-term

Max. crush resistance long-term

Fire load

mm

N

N/dm

MJ/m

115 115 135 165 195 215 210 215 240 260

800 800 1200 1200 1200 1200 1200 1200 1200 1200

1500 1500 1500 1500 1500 1500 1500 1500 1500 1500

1.20 1.20 1.36 1.52 1.68 1.80 1.84 1.92 2.16 2.48


228

Office cables

Fiber optic cables (SM / MM)

FiberConnect® Indoor cable for multifiber connectors

Outer jacket Fibers Strain relief elements

I-F(ZN)H n… Order no.

84 071 Q Q Q Q

Standardisation

IEC 60794-2

Description

Thermal properties

For fixed installation in cable ducts and conduits as well as for

Transport/storage

– 25 °C to + 70 °C

shunting purposes. Suitable for direct connector assembly on

Installation

– 5 °C to + 50 °C

MTP® connectors/MP0®connector suitable.

Operating tempe-

– 10 °C to + 70 °C

rature Composition

Mechanical properties

Cable core

(2–24) optical fibers

Strain relief

Non-metallic (aramid)

Min. bending radius static dynamic

Cable jacket

Halogen-free, flame-retardant material

Colour of jacket

O orange for multimode

Max. crush resistance

15 × outer diameter 20 × outer diameter 150 N/dm

Fire performance

O yellow for singlemode

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Smoke density

IEC 61034

Absence of halogen IEC 60754-1 Acidity of combus-

IEC 60754-2

tion gases

09

Max. Number of fibers

8 12 24

OuterØ

Wall thickness

Weight

mm

mm

kg/km

2.8 3.0 4.5

0.5 0.5 1.0

7 8 18

max. Pull force

Fire load

N

MJ/m

300 300 450

0.12 0.14 0.31

www.leoni-fiber-optics.com


FiberConnect®

FiberTech ®

FiberSwitch ®

FiberSplit®

Office cables

229

Outer jacket Fleece Subcable jacket Rip cord

Fiber optic cables (SM / MM)

FiberConnect® Indoor cable for multifiber connectors

GFR central strength member Strain relief Fibers

I-F(ZN)HH n×m… 3.0 Order no.

84 021 Q Q Q Q

Standardisation

IEC 60794-2

Description

Thermal properties

Splittable indoor cable for fixed installation in cable ducts and

Transport/storage

– 25 °C to + 70 °C

conduits. Suitable for direct connector assembly on MTP® or

Installation

– 5 °C to + 50 °C

MPO® connectors.

Operating tempe-

– 10 °C to + 70 °C

rature Composition

Mechanical properties

Cable core

GFR central strength member in the core,

Min. bending radius static

over that single elements stranded in layers (2–12) 12 optical fibers in a single

dynamic Max. crush resistance

15 × outer diameter 20 × outer diameter 1000 N/dm

element with Ø 3.0 mm Strain relief

Non-metallic (aramid)

Fire performance

Cable jacket

Halogen-free, flame-retardant material

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Colour of jacket

O orange

Smoke density

IEC 61034

Absence of halogen IEC 60754-1 Acidity of combus-

IEC 60754-2

tion gases

09

Single elements

2 4 6 8 10 12

Outer Ø

Wall thickness

Weight

mm

mm

kg/km

8.9 8.9 10.8 13.1 14.6 16.5

0.8 0.8 0.8 0.9 0.9 0.9

70 70 100 150 185 230

www.leoni-fiber-optics.com

max. Pull force

Fire load

N

MJ/m

800 800 1000 1000 1000 1000

1.16 1.16 1.71 2.57 3.69 4.96


230

Office cables

Fiber optic cables (SM / MM)

FiberConnect® Breakout cable with central strength member

Outer jacket Fleece Tight buffered or semi-tight buffered fiber GFR central strength member Strain relief elements Rip cord

AT-V(ZN)HH n… 2.1 Order no.

84 213 Q Q Q Q

Standardisation

IEC 60794-2

Description

Thermal properties

Splittable outdoor cable for fixed installatin in cable ducts and

Transport/storage

– 25 °C to + 70 °C

conduits. Suitable for direct connector assembly.

Installation

– 5 °C to + 50 °C

Operating tempera-

– 25 °C to + 70 °C

ture

Composition Cable core

GFR central strength member in the core,

Mechanical properties

over that single elements designed as

Min. bending radius

tight buffered(TB) and semi-tight buffered (STB) fiber, gel filled with non-metallic

static dynamic

Max. crush resistance

10 × outer diameter 15 × outer diameter 1000 N/dm

strain relief elements (Aramid) and a halogen-free, flame retardant subcable jacket

Fire performance

(Ø 2.1 mm), stranded in layers (2–24)

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Cable jacket

Halogen-free, flame-retardant material

Smoke density

IEC 61034

Colour of jacket

O orange for multimode

Absence of halogen

IEC 60754-1

O yellow for singlemode

Acidity of combustion IEC 60754-2 gases

09

Number of fibers

2 4 6 8 10 12 16 18 20 24 26 36

Outer Ø

Wall thickness

Weight

Fire load

mm

mm

kg/km

MJ/m

7.0 7.0 8.2 9.6 11.0 12.5 12.0 13.0 14.5 15.0 15.5 17.6

0.9 0.9 0.9 0.9 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.1

40 45 65 95 135 135 140 160 205 210 225 300

1.10 1.10 1.18 1.31 1.42 1.57 1.62 2.00 2.10 2.35 2.45 3.89

Pull force N

800 800 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000

www.leoni-fiber-optics.com


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.