222
Office cables
Fiber optic cables (SM / MM)
FiberConnect® Simplex cable
Outer jacket Strain relief elements Tight buffered or semi-tight buffered fiber
I-V(ZN)H 1… Order no.
84 QQ Q QQ Q Q
Standardisation
IEC 60794-2
Description
Thermal properties
Ideal for use as a patch cable in distribution systems as well as
Transport/storage
– 25 °C to + 70 °C
for connecting terminals due to the high flexibility and small
Installation
– 5 °C to + 50 °C
diameter.
Operating tempe-
– 10 °C to + 70 °C
rature Composition Cable core
tight buffered (TB) or semi-tight buffered
Mechanical properties
fiber (STB)
Min. bending radius static dynamic
Strain relief
Non-metallic (aramid)
Cable jacket
Halogen-free and flame-retardant
Colour of jacket
30 mm 60 mm
material
Fire performance
O orange for multimode
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
O yellow for singlemode
Smoke density
IEC 61034
£ other colours possible
Absence of halogen IEC 60754-1 Acidity of
IEC 60754-2
combustion gases
09 Outer Ø
Type
mm
1.6 1.8 2.0 2.1 2.4 2.8 3.0 3.4
Weight kg/km
I-V(ZN)H 1… I-V(ZN)H 1… I-V(ZN)H 1… I-V(ZN)H 1… I-V(ZN)H 1…* I-V(ZN)H 1… I-V(ZN)H 1… I-V(ZN)H 1…*
2.9 3.7 5.0 5.1 5.7 7.9 8.1 12.0
max. pull force long-term
max. - crush resistance long-term
Fire load
N
N/dm
MJ/m
200 200 300 300 400 400 400 400
100 100 100 100 150 150 150 150
0.09 0.10 0.11 0.12 0.16 0.18 0.21 0.32
Order no. TB
84950216 Q TB600L 84950559 Q TB900L 8404200L Q TB900L 8405600L Q TB900L 84950846 Q TB900L 8400300L Q TB900L 84950560 Q TB900L 84950770 Q TB900L
Order no. STB
84950878 Q STB600 84950212 Q STB900 84042001 Q STB900 84056001 Q STB900 84950007 Q STB900 84003001 Q STB900 84950347 Q STB900 84950194 Q STB900
* according to TS 0011/96 Deutsche Telekom
www.leoni-fiber-optics.com
FiberConnect®
FiberTech ®
FiberSwitch ®
FiberSplit®
Office cables
223
Outer jacket Strain relief elements Tight buffered or semi-tight
Fiber optic cables (SM / MM)
FiberConnect® Duplex cable
buffered fiber
I-V(ZN)H 2×1… Order no.
84 QQ Q QQ Q Q
Standardisation
IEC 60794-2
Description
Thermal properties
Ideal for use as a patch cable in distribution systems as well as
Transport/storage
– 25 °C to + 70 °C
for connecting terminals due to the high flexibility and small
Installation
– 5 °C to + 50 °C
diameter.
Operating tempe-
– 10 °C to + 70 °C
rature Composition Cable core
Tight buffered (TB) or semi-tight buffered
Mechanical properties
fiber (STB)
Min. bending radius static dynamic
30 mm 60 mm
Strain relief
Non-metallic (aramid)
Cable jacket
Halogen-free, flame-retardant material
Colour of jacket
O orange for multimode
Fire performance
O yellow for singlemode
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
£ other colours possible
Smoke density
IEC 61034
Absence of halogen IEC 60754-1 Acidity of
IEC 60754-2
combustion gases
09 Outer Ø
Type
mm
1.6 × 3.3 1.8 × 3.7 1.8 × 3.7 2.0 × 4.1 2.1 × 4.3 2.35 × 4.8 2.8 × 5.7 3.0 × 6.1
I-V(ZN)H 2×1… I-V(ZN)H 2×1… I-V(ZN)H 2×1… I-V(ZN)H 2×1… I-V(ZN)H 2×1… I-V(ZN)H 2×1… I-V(ZN)H 2×1… I-V(ZN)H 2×1…
www.leoni-fiber-optics.com
Weight
max. pull force long-term
max. - crush resistance long-term
Fire load
kg/km
N
N/dm
MJ/m
5.8 7.4 7.4 9.0 9.0 12.6 15.8 17.5
400 400 400 400 400 400 600 600
200 200 200 200 400 400 600 600
0.18 0.20 0.20 0.22 0.24 0.31 0.36 0.42
Order no. TB
84950867 Q TB600L 84950869 Q TB600L 84950875 Q TB900L 8400401L Q TB900L 84950479 Q TB900L 84950076 Q TB900L 8400501L Q TB900L 84950876 Q TB900L
Order no. STB
84950877 Q STB600 84950199 Q STB600 84950QQQQ STB900 84004011 Q STB900 84950235 Q STB900 84950253 Q STB900 84005011 Q STB900 84950250 Q STB900
224
Office cables
Fiber optic cables (SM / MM)
FiberConnect® Breakout cable, flat
Outer jacket Strain relief elements Tight buffered or semi-tight buffered fiber Subcable jacket Rip cord
I-V(ZN)HH 2×1… Order no.
84 QQ Q QQ Q Q
Standardisation
IEC 60794-2
Description
Thermal properties
Light, thin and rugged indoor cable for use as a patch cable in
Transport/storage
– 25 °C to + 70 °C
distribution systems, as connection cable for terminals as well as
Installation
– 5 °C to + 50 °C
for workstation cabling. For direct connector assembly.
Operating tempera-
– 10 °C to + 70 °C
ture Mechanical properties
Composition Cable core
Two single-fiber cables (TB or STB)
Min. bending radius
static
35 mm
arranged in parallel beside each other
(over flat side)
dynamic
65 mm
with non-metallic strain relief elements (aramid) and a halogen-free, flame-retar-
Fire performance
dant subcable jacket (Ø see table)
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
Cable jacket
Halogen-free, flame-retardant material
Smoke density
IEC 61034
Colour of jacket
O orange for multimode
Absence of halogen
IEC 60754-1
O yellow for singlemode
Acidity of combusti
IEC 60754-2
on gases
09
Single element mm
1.7 1.8 2.0 2.1 2.5 2.8
Cable outer dimensions
Type
mm
2.8 × 4.5 2.9 × 4.7 3.1 × 5.2 3.1 × 5.2 3.7 × 6.2 4.0 × 6.8
I-V(ZN)HH 2×1… I-V(ZN)HH 2×1… I-V(ZN)HH 2×1… I-V(ZN)HH 2×1… I-V(ZN)HH 2×1… I-V(ZN)HH 2×1…
Weight
max. pull force long-term
max. - crush resistance long-term
Fire load
kg/km
N
N/dm
MJ/m
16.5 17.5 19.0 19.0 26.0 32.0
400 400 600 600 600 600
400 400 400 400 600 600
0.58 0.60 0.63 0.63 0.65 0.83
Order no. TB
84950881 Q 84950882 Q 84070 QQQQ 84017 QQQQ 8401101L Q 8401201L Q
TB600L TB600L TB900L TB900L TB900L TB900L
Order no. STB
84950887 Q 84950886 Q 84070 QQQQ 84017 QQQQ 84011011 Q 84012011 Q
STB600 STB600 STB900 STB900 STB900 STB900
www.leoni-fiber-optics.com
FiberConnect®
FiberTech ®
FiberSwitch ®
FiberSplit®
Office cables
225
Outer jacket Strain relief elements Tight buffered or semi-tight buffered fiber
Fiber optic cables (SM / MM)
FiberConnect® Mini breakout cable
I-V(ZN)H n… 84 026 QQ Q Q Order no.
with UV resistant FRNC material:
84 039 Q Q Q Q Standardisation
IEC 60794-2
Description
Thermal properties
Ideal for workstation cabling due to the high flexibility and
Transport/storage
– 25 °C to + 70 °C
small dimensions. Non-metallic indoor cable for direct connec-
Installation
– 5 °C to + 50 °C
tor assembly.
Operating tempe-
– 5 °C to + 70 °C
Composition
Mechanical properties
rature Cable core
Tight buffered (TB) or semi-tight
Max. pull force
800 N 500 N/dm
buffered fiber (STB)
Max. crush
Strain relief
Non-metallic (aramid)
resistance
Cable jacket
Halogen-free, flame-retardant material
Colour of jacket
O orange for multimode
Fire performance
O yellow for singlemode
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
Smoke density
IEC 61034
Absence of halogen IEC 60754-1 Acidity of combus-
IEC 60754-2
tion gases
Number of fibers
2 4 6 8 12 16 24
Outer Ø
Weight
Min. bending radius static
dynamic
Fire load
All mini breakout cables available
mm
kg/km
mm
mm
MJ/m
with TB and STB fibers
4.2 5.6 5.9 6.1 7.0 8.4 9.4
14 21 25 30 38 59 72
40 55 60 60 70 85 95
65 85 90 90 95 120 135
0.45 0.47 0.50 0.52 0.55 0.74 0.92
Order no. on request
www.leoni-fiber-optics.com
09
226
Office cables
Fiber optic cables (SM / MM)
FiberConnect® Breakout cable
Outer jacket Fleece Tight buffered or semi-tight buffered fiber Central strength member Subcable jacket Strain relief elements Rip cord
I-V(ZN)HH n… Order no.
see table
Standardisation
IEC 60794-2
Description
Thermal properties
Non-metallic, rugged cable for installation in the riser and
Transport/storage
– 25 °C to + 70 °C
horizontal indoor area. For direct connector assembly.
Installation
– 5 °C to + 50 °C
Operating tempe-
– 10 °C to + 70 °C
rature
Composition Cable core
Stranded single elements designed as
Fire performance
tight buffered fiber (TB) or semi-tight
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
buffered fiber (STB) with non-metallic
Smoke density
IEC 61034
strain relief elements (aramid) and halo-
Absence of halogen IEC 60754-1
gen-free, flame-retardant subcable jacket
Acidity of
(Ø see table)
combustion gases
IEC 60754-2
Cable jacket
halogen-free, flame-retardant material
Colour of jacket
O orange for multimode
Note
O yellow for singlemode
The cable is alternatively available with non-metallic rodent protection (B).
09 Single cable with 1.8 mm Ø, buffered fiber: TB600, tight buffered fiber with Ø 600 µm Order no. 84 015 Q Q Z Q Number of fibers
2 4 6 8 10 12 16 18 20 24 48
Outer Ø
Weight
mm
kg/km
6.0 6.0 6.9 8.3 9.9 11.0 10.7 11.3 11.7 12.9 17.2
35 35 47 69 105 119 106 116 129 162 245
Min. bending radius static
Min. bending radius dynamic
mm
mm
60 60 70 85 100 110 110 115 120 130 175
85 85 105 125 150 165 160 170 180 200 260
Max. pull force long-term
Max. crush resistance long-term
Fire load
N
N/dm
MJ/m
800 800 800 800 800 800 800 800 800 800 800
0.63 0.63 0.89 1.22 2.01 2.37 2.03 2.27 2.54 3.11 5.43
600 600 800 800 800 800 1000 1000 1200 1200 1200
www.leoni-fiber-optics.com
FiberTech ®
FiberSwitch ®
FiberSplit®
Office cables
Single cable with 2.0 mm Ø, tight buffered fiber, semi-tight buffered fiber or superstrip fiber with 900 µm Order no. Number of fibers
2 4 6 8 10 12 16 18 20 24
84 054 Q Q L Q (TB900L) | 84 054 Q Q 1 Q (STB900) | 84 054 Q Q 7 Q (STB900H) Outer Ø
Weight
mm
kg/km
6.8 6.8 8.0 9.4 10.8 12.3 11.6 12.6 14.1 14.2
45 45 60 85 125 150 140 160 180 200
Min. bending radius static mm
70 70 80 95 110 125 120 130 145 150
Min. bending radius dynamic mm
105 105 120 145 165 190 180 195 220 225
Max. pull force long-term
Max. crush resistance long-term
Fire load
N
N/dm
MJ/m
1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
1.08 1.08 1.15 1.28 1.39 1.54 1.56 1.88 2.07 2.23
Max. crush resistance long-term
Fire load
N/dm
MJ/m
1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
1.10 1.10 1.18 1.31 1.42 1.57 1.62 2.00 2.10 2.35
800 800 1000 1000 1000 1000 1000 1000 1000 1000
227
Fiber optic cables (SM / MM)
FiberConnect®
Single cable with 2.1 mm Ø, tight buffered fiber, semi-tight buffered fiber or superstrip fiber with Ø 900 µm Order no. Number of fibers
2 4 6 8 10 12 16 18 20 24
84 013 Q Q L Q (TB900L) | 84 013 Q Q 1 Q (STB900) | 84 013 Q Q 7 Q (STB900H) Outer Ø
Weight
mm
kg/km
7.0 7.0 8.2 9.8 11.0 12.5 12.0 13.0 14.5 15.0
40 45 65 95 135 155 140 160 205 210
Min. bending radius static mm
70 70 80 95 110 125 120 130 145 150
Min. bending radius dynamic mm
105 105 120 145 165 190 180 195 220 225
Max. pull force long-term N
800 800 1000 1000 1000 1000 1000 1000 1000 1000
09 Single cable with 2.5 mm Ø, tight buffered fiber, semi-tight buffered fiber or superstrip fiber with Ø 900 µm Order no. Number of fibers
2 4 6 8 10 12 16 18 20 24
84 010 Q Q L Q (TB900L) | 84 010 Q Q 1 Q (STB900) | 84 010 Q Q 7 Q (STB900H) Outer Ø
Weight
mm
kg/km
7.5 7.5 9.0 11.0 13.0 14.5 14.0 14.5 16.0 17.0
www.leoni-fiber-optics.com
45 50 75 110 160 182 160 175 225 245
Min. bending radius static mm
75 75 90 110 130 145 140 145 160 175
Min. bending radius dynamic
Max. pull force long-term
Max. crush resistance long-term
Fire load
mm
N
N/dm
MJ/m
115 115 135 165 195 215 210 215 240 260
800 800 1200 1200 1200 1200 1200 1200 1200 1200
1500 1500 1500 1500 1500 1500 1500 1500 1500 1500
1.20 1.20 1.36 1.52 1.68 1.80 1.84 1.92 2.16 2.48
228
Office cables
Fiber optic cables (SM / MM)
FiberConnect® Indoor cable for multifiber connectors
Outer jacket Fibers Strain relief elements
I-F(ZN)H n… Order no.
84 071 Q Q Q Q
Standardisation
IEC 60794-2
Description
Thermal properties
For fixed installation in cable ducts and conduits as well as for
Transport/storage
– 25 °C to + 70 °C
shunting purposes. Suitable for direct connector assembly on
Installation
– 5 °C to + 50 °C
MTP® connectors/MP0®connector suitable.
Operating tempe-
– 10 °C to + 70 °C
rature Composition
Mechanical properties
Cable core
(2–24) optical fibers
Strain relief
Non-metallic (aramid)
Min. bending radius static dynamic
Cable jacket
Halogen-free, flame-retardant material
Colour of jacket
O orange for multimode
Max. crush resistance
15 × outer diameter 20 × outer diameter 150 N/dm
Fire performance
O yellow for singlemode
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
Smoke density
IEC 61034
Absence of halogen IEC 60754-1 Acidity of combus-
IEC 60754-2
tion gases
09
Max. Number of fibers
8 12 24
OuterØ
Wall thickness
Weight
mm
mm
kg/km
2.8 3.0 4.5
0.5 0.5 1.0
7 8 18
max. Pull force
Fire load
N
MJ/m
300 300 450
0.12 0.14 0.31
www.leoni-fiber-optics.com
FiberConnect®
FiberTech ®
FiberSwitch ®
FiberSplit®
Office cables
229
Outer jacket Fleece Subcable jacket Rip cord
Fiber optic cables (SM / MM)
FiberConnect® Indoor cable for multifiber connectors
GFR central strength member Strain relief Fibers
I-F(ZN)HH n×m… 3.0 Order no.
84 021 Q Q Q Q
Standardisation
IEC 60794-2
Description
Thermal properties
Splittable indoor cable for fixed installation in cable ducts and
Transport/storage
– 25 °C to + 70 °C
conduits. Suitable for direct connector assembly on MTP® or
Installation
– 5 °C to + 50 °C
MPO® connectors.
Operating tempe-
– 10 °C to + 70 °C
rature Composition
Mechanical properties
Cable core
GFR central strength member in the core,
Min. bending radius static
over that single elements stranded in layers (2–12) 12 optical fibers in a single
dynamic Max. crush resistance
15 × outer diameter 20 × outer diameter 1000 N/dm
element with Ø 3.0 mm Strain relief
Non-metallic (aramid)
Fire performance
Cable jacket
Halogen-free, flame-retardant material
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
Colour of jacket
O orange
Smoke density
IEC 61034
Absence of halogen IEC 60754-1 Acidity of combus-
IEC 60754-2
tion gases
09
Single elements
2 4 6 8 10 12
Outer Ø
Wall thickness
Weight
mm
mm
kg/km
8.9 8.9 10.8 13.1 14.6 16.5
0.8 0.8 0.8 0.9 0.9 0.9
70 70 100 150 185 230
www.leoni-fiber-optics.com
max. Pull force
Fire load
N
MJ/m
800 800 1000 1000 1000 1000
1.16 1.16 1.71 2.57 3.69 4.96
230
Office cables
Fiber optic cables (SM / MM)
FiberConnect® Breakout cable with central strength member
Outer jacket Fleece Tight buffered or semi-tight buffered fiber GFR central strength member Strain relief elements Rip cord
AT-V(ZN)HH n… 2.1 Order no.
84 213 Q Q Q Q
Standardisation
IEC 60794-2
Description
Thermal properties
Splittable outdoor cable for fixed installatin in cable ducts and
Transport/storage
– 25 °C to + 70 °C
conduits. Suitable for direct connector assembly.
Installation
– 5 °C to + 50 °C
Operating tempera-
– 25 °C to + 70 °C
ture
Composition Cable core
GFR central strength member in the core,
Mechanical properties
over that single elements designed as
Min. bending radius
tight buffered(TB) and semi-tight buffered (STB) fiber, gel filled with non-metallic
static dynamic
Max. crush resistance
10 × outer diameter 15 × outer diameter 1000 N/dm
strain relief elements (Aramid) and a halogen-free, flame retardant subcable jacket
Fire performance
(Ø 2.1 mm), stranded in layers (2–24)
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
Cable jacket
Halogen-free, flame-retardant material
Smoke density
IEC 61034
Colour of jacket
O orange for multimode
Absence of halogen
IEC 60754-1
O yellow for singlemode
Acidity of combustion IEC 60754-2 gases
09
Number of fibers
2 4 6 8 10 12 16 18 20 24 26 36
Outer Ø
Wall thickness
Weight
Fire load
mm
mm
kg/km
MJ/m
7.0 7.0 8.2 9.6 11.0 12.5 12.0 13.0 14.5 15.0 15.5 17.6
0.9 0.9 0.9 0.9 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.1
40 45 65 95 135 135 140 160 205 210 225 300
1.10 1.10 1.18 1.31 1.42 1.57 1.62 2.00 2.10 2.35 2.45 3.89
Pull force N
800 800 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
www.leoni-fiber-optics.com