Brochure glasvezelkabels voor marine en offshore

Page 1

FiberConnect®

FiberTech ®

FiberSwitch ®

FiberSplit®

Marine cables

265

FiberConnect® Universal cable with functional integrity 90 min

Outer jacket Out Strain relief elements / Str Out Outer fire protection barrier Rip cord

Fiber optic cables (SM / MM)

rodent-protected

Inner fire protection barrier Inn Loose tube, gel-filled Loo

GL U-D(ZN)BH n… FS

Functional integrity in the event of fire

Order no.

84 040 Q Q Q Q 222 ZGELO

Standardisation

IEC 60794-2

for at least 90 minutes

Description

Mechanical properties

Non-metallic, light and flexible cable with approval by Germani-

Min. bending radius static dynamic

scher Lloyd and Det Norske Veritas (DNV).

15 × outer diameter 20 × outer diameter

For fixed installation on ships and offshore facilities in safety-

Max. pull force

2500 N

related areas.

Max. crush resistance

3000 N/dm

Resistance to impacts

10 impacts/2 Nm

Composition Cable core

Loose tube, gel-filled

Fire performance

Inner fire protection barrier

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

multifunctional, reinforced glass rovings

Smoke density

IEC 61034

as non-metallic strain relief elements

Absence of halogen IEC 60754-1

and rodent protection

Acidity of combus-

Cable jacket

Halogen-free, flame-retardant material

tion gases

Colour of jacket

O orange

Armour

IEC 60754-2

Functional integrity test Thermal properties

According to IEC 60 331-11, IEC 60 331-25 and EN 50200

Transport/storage

– 25 °C to + 70 °C

Installation

– 5 °C to + 50 °C

Operating tempe-

– 20 °C to + 60 °C

90 min (VDE test report)

rature

Max. number of fibers

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

12 24

10.3 10.8

115 125

1.03 1.28

www.leoni-fiber-optics.com

09


266

Marine cables

Fiber optic cables (SM / MM)

FiberConnect® Breakout cable

FRNC outer jacket Fiber optic buffered fiber Strain relief element GFR strength member Fleece wrapping FRNC subcable jacket Rip cord

GL AT-V(ZN)H(ZN)H n… Order no.

see table

Standardisation

IEC 60794-2

Description

Thermal properties

Non-metallic, light and flexible cable with approval by

Transport/storage

– 25 °C to + 80 °C

Germanischer Lloyd and Det Norske Veritas (DNV).

Installation

– 5 °C to + 50 °C

For fixed installation on ships and offshore facilities in areas

Operating tempe-

– 20 °C to + 80 °C

at risk of fire.

rature Mechanical properties

Composition Cable core

Min. bending radius static dynamic

GFR strength member with stranding

15 × outer diameter 20 × outer diameter

elements, designed as semi-tight buffered

Max. pull force

1200 N

fiber (STB900H), gel-filled with non-me-

Max. crush resistance

1000 N/dm

tallic strain relief elements (aramid) and a

Resistance to impacts

10 impacts/2 Nm

halogen-free, flame-retardant subcable jacket (Ø 2.9 mm)

Fire performance

Strain relief

Aramid yarns

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Cable jacket

Halogen-free, flame-retardant material

Smoke density

IEC 61034

Colour of jacket

O RAL 6029 mint green

Absence of halogen IEC 60754-1

09

Acidity of combus-

IEC 60754-2

tion gases

Number of fibers max.

Outer Ø

mm

kg/km

MJ/m

2 4 6 8 10 12

10.1 10.1 11.8 13.6 15.4 17.2

85 85 120 160 200 245

1.28 1.28 1.59 1.80 2.14 2.48

Weight

Fire load Order no.

84950481 Q 84950478 Q 84950482 Q 84950483 Q 84950484 Q 84950485 Q

688 ZGELO 688 ZGELO 688 ZGELO 688 ZGELO 688 ZGELO 688 ZGELO

www.leoni-fiber-optics.com


FiberConnect®

FiberTech ®

FiberSwitch ®

FiberSplit®

Marine cables

267

FiberConnect® Breakout cable with central strength member

Outer jacket Fleece Fiber optic buffered fiber GFR strength member Strain relief elements

Fiber optic cables (SM / MM)

according to VG 95218-30 type B

FRNC subcable jacket

Rip cord

AT-V(ZN)HH n… TB900L 2.2 VG Order no.

84 066 Q Q Q Q

Standardisation

VG 95218-30 type B and IEC 60794-2

Description

Thermal properties

Splittable breakout cable for fixed installation on ships on

Transport/storage

– 33 °C to + 85 °C

and below decks but not under water. For direct connector

Installation

– 10 °C to + 50 °C

assembly.

Operating tempe-

– 33 °C to + 85 °C

rature Mechanical properties

Composition Cable core

GFR strength member in the core, over

Min. bending radius static dynamic

that single elements designed as tight buffered fiber (TB900L) with non-metallic

Max. crush resistance

15 × outer diameter 20 × outer diameter 2000 N/dm

strain relief elements (aramid) and a halo-

Cable jacket Colour of jacket

gen-free, flame-retardant subcable jacket

Fire performance

(Ø 2.2 mm), stranded in layers (2–16)

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-24 Cat. C

Halogen-free, flame-retardant and

Smoke density

IEC 61034

oil restistant material (FRNC)

Absence of halogen IEC 60754-1

O orange

Acidity of combus-

IEC 60754-2

tion gases Chemical properties Very good restistance to oil, grease, acids and alkaline solutions. Number of fibers max.

2 4 6 8 10 12 16

OuterØ

Wall thickness

Weight

mm

mm

kg/km

N

7.7 7.7 9.1 10.4 12.2 13.5 13.3

1.1 1.1 1.1 1.1 1.3 1.3 1.3

69 69 88 125 175 205 200

1200 1200 1800 2400 2400 2400 2400

www.leoni-fiber-optics.com

Pull force

09


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.