FiberConnect®
FiberTech ®
FiberSwitch ®
FiberSplit®
Marine cables
265
FiberConnect® Universal cable with functional integrity 90 min
Outer jacket Out Strain relief elements / Str Out Outer fire protection barrier Rip cord
Fiber optic cables (SM / MM)
rodent-protected
Inner fire protection barrier Inn Loose tube, gel-filled Loo
GL U-D(ZN)BH n… FS
Functional integrity in the event of fire
Order no.
84 040 Q Q Q Q 222 ZGELO
Standardisation
IEC 60794-2
for at least 90 minutes
Description
Mechanical properties
Non-metallic, light and flexible cable with approval by Germani-
Min. bending radius static dynamic
scher Lloyd and Det Norske Veritas (DNV).
15 × outer diameter 20 × outer diameter
For fixed installation on ships and offshore facilities in safety-
Max. pull force
2500 N
related areas.
Max. crush resistance
3000 N/dm
Resistance to impacts
10 impacts/2 Nm
Composition Cable core
Loose tube, gel-filled
Fire performance
Inner fire protection barrier
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
multifunctional, reinforced glass rovings
Smoke density
IEC 61034
as non-metallic strain relief elements
Absence of halogen IEC 60754-1
and rodent protection
Acidity of combus-
Cable jacket
Halogen-free, flame-retardant material
tion gases
Colour of jacket
O orange
Armour
IEC 60754-2
Functional integrity test Thermal properties
According to IEC 60 331-11, IEC 60 331-25 and EN 50200
Transport/storage
– 25 °C to + 70 °C
Installation
– 5 °C to + 50 °C
Operating tempe-
– 20 °C to + 60 °C
90 min (VDE test report)
rature
Max. number of fibers
Outer Ø
Weight
Fire load
mm
kg/km
MJ/m
12 24
10.3 10.8
115 125
1.03 1.28
www.leoni-fiber-optics.com
09
266
Marine cables
Fiber optic cables (SM / MM)
FiberConnect® Breakout cable
FRNC outer jacket Fiber optic buffered fiber Strain relief element GFR strength member Fleece wrapping FRNC subcable jacket Rip cord
GL AT-V(ZN)H(ZN)H n… Order no.
see table
Standardisation
IEC 60794-2
Description
Thermal properties
Non-metallic, light and flexible cable with approval by
Transport/storage
– 25 °C to + 80 °C
Germanischer Lloyd and Det Norske Veritas (DNV).
Installation
– 5 °C to + 50 °C
For fixed installation on ships and offshore facilities in areas
Operating tempe-
– 20 °C to + 80 °C
at risk of fire.
rature Mechanical properties
Composition Cable core
Min. bending radius static dynamic
GFR strength member with stranding
15 × outer diameter 20 × outer diameter
elements, designed as semi-tight buffered
Max. pull force
1200 N
fiber (STB900H), gel-filled with non-me-
Max. crush resistance
1000 N/dm
tallic strain relief elements (aramid) and a
Resistance to impacts
10 impacts/2 Nm
halogen-free, flame-retardant subcable jacket (Ø 2.9 mm)
Fire performance
Strain relief
Aramid yarns
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
Cable jacket
Halogen-free, flame-retardant material
Smoke density
IEC 61034
Colour of jacket
O RAL 6029 mint green
Absence of halogen IEC 60754-1
09
Acidity of combus-
IEC 60754-2
tion gases
Number of fibers max.
Outer Ø
mm
kg/km
MJ/m
2 4 6 8 10 12
10.1 10.1 11.8 13.6 15.4 17.2
85 85 120 160 200 245
1.28 1.28 1.59 1.80 2.14 2.48
Weight
Fire load Order no.
84950481 Q 84950478 Q 84950482 Q 84950483 Q 84950484 Q 84950485 Q
688 ZGELO 688 ZGELO 688 ZGELO 688 ZGELO 688 ZGELO 688 ZGELO
www.leoni-fiber-optics.com
FiberConnect®
FiberTech ®
FiberSwitch ®
FiberSplit®
Marine cables
267
FiberConnect® Breakout cable with central strength member
Outer jacket Fleece Fiber optic buffered fiber GFR strength member Strain relief elements
Fiber optic cables (SM / MM)
according to VG 95218-30 type B
FRNC subcable jacket
Rip cord
AT-V(ZN)HH n… TB900L 2.2 VG Order no.
84 066 Q Q Q Q
Standardisation
VG 95218-30 type B and IEC 60794-2
Description
Thermal properties
Splittable breakout cable for fixed installation on ships on
Transport/storage
– 33 °C to + 85 °C
and below decks but not under water. For direct connector
Installation
– 10 °C to + 50 °C
assembly.
Operating tempe-
– 33 °C to + 85 °C
rature Mechanical properties
Composition Cable core
GFR strength member in the core, over
Min. bending radius static dynamic
that single elements designed as tight buffered fiber (TB900L) with non-metallic
Max. crush resistance
15 × outer diameter 20 × outer diameter 2000 N/dm
strain relief elements (aramid) and a halo-
Cable jacket Colour of jacket
gen-free, flame-retardant subcable jacket
Fire performance
(Ø 2.2 mm), stranded in layers (2–16)
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-24 Cat. C
Halogen-free, flame-retardant and
Smoke density
IEC 61034
oil restistant material (FRNC)
Absence of halogen IEC 60754-1
O orange
Acidity of combus-
IEC 60754-2
tion gases Chemical properties Very good restistance to oil, grease, acids and alkaline solutions. Number of fibers max.
2 4 6 8 10 12 16
OuterØ
Wall thickness
Weight
mm
mm
kg/km
N
7.7 7.7 9.1 10.4 12.2 13.5 13.3
1.1 1.1 1.1 1.1 1.3 1.3 1.3
69 69 88 125 175 205 200
1200 1200 1800 2400 2400 2400 2400
www.leoni-fiber-optics.com
Pull force
09