182
Optical cables with UL approval
Fiber Optic Cables
Simplex indoor cable
FiberConnect® I-V(ZN)H 1… UL OFNR
outer jacket strain relief elements
Order no.
tight buffered or
84950407
semi-tight buffered fiber
Standardisation DIN VDE 0888, part 4 and IEC 60794-2 Application
Indoor cable with UL approval type OFNR (riser) for USA and Canada. Ideal for use in distribution systems as well as for connecting terminals.
Construction
cable core
flame-retardant semi-tight buffered fiber (STB900H)
strain relief elements
non-metallic (aramid)
cable jacket
halogen-free and flame-retardant material
colour of jacket
blue
Thermal
transport and storage
–25 °C to +70 °C
properties
installation temperature –5 °C to +50 °C operating temperature –10 °C to +70 °C
Mechanical
outer dimensions
2.9 mm
properties
weight
10.0 kg/km
min. bending radius
static
30 mm
dynamic
60 mm
max. pull force
400 N
max. crush resistance
150 N/dm
Fire
flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
performance
smoke density
IEC 61034
halogen-free
IEC 60754-1
acidity of gases
IEC 60754-2
fire load
0.18 MJ/m
UL approbation type
OFNR (NEC Article 770, UL 1651), c(UL)us
Approval
www.leoni-fiber-optics.com
FiberConnect®
FiberTech ®
FiberSwitch ®
FiberSplit®
Optical cables with UL approval
183
Fiber optic cables
Duplex indoor cable
FiberConnect® I-V(ZN)H 2x1 UL OFNR
outer jacket strain relief elements
Order no.
tight buffered or
84005017 ZUL00
semi-tight buffered fiber
Standardisation DIN VDE 0888, part 6 and IEC 60794-2 Application
Indoor cable with UL approval type OFNR (riser) for USA and Canada. Ideal for use in distribution systems as well as for connecting terminals.
Construction
cable core
2 flame-retardant tight buffered fibers (STB 900H)
strain relief elements
non-metallic (aramid)
cable jacket
halogen-free and flame-retardant material
colour of jacket
blue
Thermal
transport and storage
–25 °C to +70 °C
properties
installation temperature –5 °C to +50 °C operating temperature –10 °C to +70 °C
Mechanical
outer dimensions
2.8 mm x 5.7 mm
properties
weight
15.8 kg/km
min. bending radius
static
30 mm
dynamic
60 mm
max. pull force
600 N
max. crush resistance
600 N/dm
Fire
flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
performance
smoke density
IEC 61034
halogen-free
IEC 60754-1
acidity of gases
IEC 60754-2
fire load
0.36 MJ/m
UL approbation type
OFNR (NEC Article 770, UL 1651), c(UL)us
Approval
www.leoni-fiber-optics.com
184
Optical cables with UL approval
Fiber Optic Cables
Breakout cable, flat
FiberConnect® I-V(ZN)HH 2x1… UL OFNR
outer jacket strain relief elements
Order no.
tight buffered or
84011011 ZUL00
Standardisation DIN VDE 0888, part 6 and IEC 60794-2
semi-tight buffered fiber
Application
Indoor cable with UL approval type OFNR (riser). Ideal for use in
subcable jacket
distribution systems, for connecting terminals as well as for fixed
ripcord
installation. Construction
cable core
two single-fiber cables (STB900) arranged in parallel beside each other with non-metallic strain relief elements (aramid) and halogen-free, flame-retardant subcable jacket (Ø 2.5 mm)
cable jacket
halogen-free and flame-retardant material
colour of jacket
orange for multimode, yellow for singlemode
Thermal
transport and storage
–25 °C to +70 °C
properties
installation temperature –5 °C to +50 °C operating temperature –10 °C to +70 °C
Mechanical
outer dimensions
properties
weight
26.0 kg/km
min. bending radius
static
35 mm
(over flat side)
dynamic
65 mm
max. pull force
600 N
3.7 x 6.2 mm
max. crush resistance
600 N/dm
Fire
flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
performance
smoke density
IEC 61034
halogen-free
IEC 60754-1
acidity of gases
IEC 60754-2
fire load
0.65 MJ/m
UL approbation type
OFNR (NEC Article 770, UL 1651)
Approval
www.leoni-fiber-optics.com
FiberConnect®
FiberTech ®
FiberSwitch ®
FiberSplit®
Optical cables with UL approval
185
Fiber optic cables
Breakout cable, flat
FiberConnect® I-V(ZN)HH 2x1 UL OFN
outer jacket strain relief elements
Order no.
tight buffered or
84950500
Standardisation DIN VDE 0888, part 6 and IEC 60794-2
semi-tight buffered fiber
Application
Indoor cable with UL approval type OFN (General Purpose) for USA
subcable jacket
and Canada. Ideal for use in distribution systems, for connecting
ripcord
terminals as well as for fixed installation. Construction
cable core
Two single-fiber cables (STB900) arranged in parallel beside each other with non-metallic strain relief elements (aramid) and halogen-free, flame-retardant subcable jacket (Ø 2.0 mm)
cable jacket
halogen-free and flame-retardant material
colour of jacket
orange for multimode, yellow for singlemode
Thermal
transport and storage
–25 °C to +70 °C
properties
installation temperature –5 °C to +50 °C operating temperature –10 °C to +70 °C
Mechanical
outer dimensions
properties
weight
18.5 kg/km
min. bending radius
static
30 mm
(over flat side)
dynamic
60 mm
max. pull force
600 N
Fire performance
Approval
3.0 x 5.0 mm
max. crush resistance
1000 N/dm
flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
smoke density
IEC 61034
halogen-free
IEC 60754-1
acidity of gases
IEC 60754-2
fire load
0.62 MJ/m
UL approbation type
OFN (NEC Article 770, UL 1651), c(UL)us
www.leoni-fiber-optics.com
186
Optical cables with UL approval
Fiber Optic Cables
Duplex outdoor cable
FiberConnect® AT-V(ZN)YY 2… UL OFNR outer jacket
Order no.
fleece
84950632
Standardisation DIN VDE 0888, part 6 and IEC 60794-2
reactive element
Application
Extremely temperature-stable and UV-resistant outdoor cable,
optical buffered fiber
tested according to UL OFNR flame test.
strain relief elements
Ideal for use in harsh environments such as mobile base stations. Construction
cable core
stranding consisting of two PVC single cables (TB900L) with non-metallic strain relief elements (aramid) (Ø 2.4 mm)
cable jacket
flame-retardant polyvinyl chloride (PVC)
colour of jacket
black
Thermal
transport and storage
–55 °C to +85 °C
properties
installation temperature –20 °C to +60 °C operating temperature –40 °C to +85 °C
Mechanical
outer dimensions
properties
weight
44.0 kg/km
min. bending radius
static
70 mm
dynamic
105 mm
Fire
7.0 mm
max. pull force
600 N
max. crush resistance
800 N/dm
flame retardancy
IEC 60332-1-2
UL approbation type
OFNR (NEC Article 770, UL 1651), c(UL)us
performance Approval
www.leoni-fiber-optics.com
FiberConnect®
FiberTech ®
FiberSwitch ®
FiberSplit®
Optical cables with UL approval
187
Fiber optic cables
Duplex outdoor cable
FiberConnect® AT-V(ZN)YY 2… UL AWM Style outer jacket
Order no.
reactive element
84950504
Standardisation DIN VDE 0888, part 6 and IEC 60794-2
optical buffered fiber
Application
Extremely temperature-stable and UV-resistant outdoor cable,
ripcord
tested acc. to UL VW-1 flame test.
strain relief elements
Ideal for use in harsh environments such as mobile base stations. Construction
cable core
stranding consisting of two PVC single cables (TB900A) with non-metallic strain relief elements (aramid) (Ø 2.4 mm)
cable jacket
flame-retardant polyvinyl chloride (PVC)
colour of jacket
black
Thermal
transport and storage
–55 °C to +85 °C
properties
installation temperature –20 °C to +60 °C operating temperature –40 °C to +85 °C
Mechanical
outer dimensions
properties
weight
44.0 kg/km
min. bending radius
static
70 mm
dynamic
105 mm
max. pull force Fire
800 N
max. crush resistance
800 N/dm
flame retardancy
IEC 60332-1-2 and
performance Approval
7.0 mm
VW-1 flame test UL approbation type
www.leoni-fiber-optics.com
UL-AWM Style 5432
188
Optical cables with UL approval
Fiber Optic Cables
Breakout outdoor cable
FiberConnect® AT-V(ZN)YY n … UL OFNR
PVC outer jacket fleece wrapping
Order no.
ripcord
84 217
Standardisation following DIN VDE 0888-5 and IEC 60794-2
GFR central strength member
Application
Extremely temperature-stable and UV-resistant outdoor cable,
PVC subcable jacket
tested acc. to UL OFNR flame test. Ideal for use in harsh environments
optical buffered fiber
such as mobile base stations and wind turbines.
strain relief elements
For direct connector assembly. Construction
cable core
Glass fiber-reinforced central strength member in the core, over that single elements stranded in one layer. Single element (TB900L) made of PVC (Ø 2.2 mm), colour orange for multimode and yellow for singlemode and non-metallic strain relief elements (aramid)
cable jacket
flame-retardant polyvinyl chloride (PVC)
colour of jacket
black
Thermal
transport and storage
–40 °C to +85 °C
properties
installation temperature –5 °C to +50 °C operating temperature –40 °C to +85 °C
Mechanical
min. bending radius
properties
static
10 x outer diameter
dynamic
15 x outer diameter
max. crush resistance
1000 N/dm
flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
Approval
UL approbation type
type OFNR (NEC Article 770, UL 1651), c(UL)us
Chemical
good resistance to oil, petrol, acids and alkaline solutions
properties
UV resistance of outer jacket according to DIN EN ISO 4892-2,
Fire performance
testing procedure A, UV applications up to 500 hours.
Max no. of fibers
2 4 6 8 10 12
Outer Ø
Wall thickness
Weight
max. pull force
mm
mm
kg/km
N
7.8 7.8 9.2 10.5 11.9 13.3
1.2 1.2 1.2 1.2 1.2 1.2
60 60 85 110 140 180
800 800 1200 1200 1200 1200 www.leoni-fiber-optics.com
FiberConnect®
FiberTech ®
FiberSwitch ®
FiberSplit®
Optical cables with UL approval
189
Fiber optic cables
Breakout outdoor cable
PVC outer jacket
FiberConnect® AT-V(ZN)Y(ZN)Y n … UL OFNR
strain relief elements fleece wrapping
Order no.
ripcord
84 218
Standardisation following DIN VDE 0888-5 and IEC 60794-2
GFR central strength member
Application
Extremely temperature-stable and UV-resistant outdoor cable,
PVC subcable jacket
tested acc. to UL OFNR flame test. Ideal for use in harsh environments
optical buffered fiber
such as mobile base stations and wind turbines.
strain relief elements
For direct connector assembly. Construction
cable core
Glass fiber-reinforced central strength member in the core, over that single elements stranded in one layer. Single element (TB900L) made of PVC (Ø 2.2 mm), colour orange for multimode and yellow for singlemode and non-metallic strain relief elements (aramid)
strain relief elements
non-metallic (aramid) in two layers
cable jacket
flame-retardant polyvinyl chloride (PVC)
colour of jacket
black
Thermal
transport and storage
–40 °C to +85 °C
properties
installation temperature –5 °C to +50 °C operating temperature –40 °C to +85 °C
Mechanical
min. bending radius
properties
static
10 x outer diameter
dynamic
15 x outer diameter
max. crush resistance
2000 N/dm
flame retardancy
OFNR (NEC Article 770, UL 1651), c(UL)us
Approval
UL approbation type
Type OFNR (NEC Article 770, UL 1651), c(UL)us
Chemical
good resistance to oil, petrol, acids and alkaline solutions
properties
UV resistance of outer jacket according to DIN EN ISO 4892-2,
Fire performance
testing procedure A, UV applications up to 500 hours.
Max. no. of fibers
2 4 6 8 10 12
www.leoni-fiber-optics.com
Outer Ø
Wall thickness
Weight
mm
mm
kg/km
8.4 8.4 10.1 11.4 12.8 14.2
1.2 1.2 1.2 1.2 1.2 1.2
70 70 95 120 150 190
max. pull force N
2000 2000 3000 3000 3000 3000