136
Office cables
Fiber Optic Cables
Simplex cable
FiberConnect® I-V(ZN)H 1…
outer jacket strain relief elements
84
Order no.
tight buffered or semi-tight buffered fiber
Standardisation DIN VDE 0888, part 4 and IEC 60794-2 ideal for use as a patch cable in distribution systems as well as
Application
for connecting terminals due to the high flexibility and small diameter Construction
cable core
tight buffered fiber (TB) or semi-tight buffered fiber (STB)
strain relief elements
non-metallic (aramid)
cable jacket
halogen-free and flame-retardant material
colour of jacket
orange for multimode, yellow for singlemode £ other colours possible!
Thermal
transport and storage
properties
installation temperature –5 °C to +50 °C
–25 °C to +70 °C
operating temperature –10 °C to +70 °C min. bending radius
Mechanical properties
static
30 mm
dynamic
60 mm
Fire
flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
performance
smoke density
IEC 61034
halogen-free
IEC 60754-1
acidity of gases
IEC 60754-2
Outer Ø
Type
mm
1.6 1.8 2.0 2.1 2.4 2.8 3.0 3.4
Weight
kg/km
I-V(ZN)H 1… I-V(ZN)H 1… I-V(ZN)H 1… I-V(ZN)H 1… I-V(ZN)H 1…* I-V(ZN)H 1… I-V(ZN)H 1… I-V(ZN)H 1…*
2.9 3.7 5.0 5.1 5.7 7.9 8.1 12.0
Max. pull force long-term
Max. crush resistance long-term
fire load
N
N/dm
MJ/m
200 200 300 300 400 400 400 400
100 100 100 100 150 150 150 150
0.09 0.10 0.11 0.12 0.16 0.18 0.21 0.32
Order no. TB
84950216 TB600L 84950559 TB900L 8404200L TB900L 8405600L TB900L 84950846 TB900L 8400300L TB900L 84950560 TB900L 84950770 TB900L
Order no. STB
84950878 STB600 84950212 STB900 84042001 STB900 84056001 STB900 84950007 STB900 84003001 STB900 84950347 STB900 84950194 STB900
* acc. to TS 0011/96 Deutsche Telekom
www.leoni-fiber-optics.com
FiberConnect®
FiberTech ®
FiberSwitch ®
FiberSplit® Office cables
137
Fiber optic cables
Duplex cable
FiberConnect® I-V(ZN)H 2x1…
outer jacket strain relief elements
84
Order no.
tight buffered or semi-tight buffered fiber
Standardisation DIN VDE 0888, part 6 and IEC 60794-2 Ideal for use as a patch cable in distribution systems as well as for
Application
connecting terminals due to the high flexibility and small diameter Construction
cable core
tight buffered fiber (TB) or semi-tight buffered fiber (STB)
strain relief elements
non-metallic (aramid)
cable jacket
halogen-free and flame-retardant material
colour of jacket
orange for multimode, yellow for singlemode £ other colours possible!
Thermal
transport and storage
properties
installation temperature –5 °C to +50 °C
–25 °C to +70 °C
operating temperature –10 °C to +70 °C min. bending radius
static
30 mm
dynamic
60 mm
Fire
flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
performance
smoke density
IEC 61034
halogen-free
IEC 60754-1
acidity of gases
IEC 60754-2
Mechanical properties
Outer Ø
Type
mm
1.6 x 3.3 1.8 x 3.7 1.8 x 3.7 2.0 x 4.1 2.1 x 4.3 2.35 x 4.8 2.8 x 5.7 3.0 x 6.1
I-V(ZN)H 2x1… I-V(ZN)H 2x1… I-V(ZN)H 2x1… I-V(ZN)H 2x1… I-V(ZN)H 2x1… I-V(ZN)H 2x1… I-V(ZN)H 2x1… I-V(ZN)H 2x1…
www.leoni-fiber-optics.com
Weight
Max. pull force long-term
Max. crush resistance long-term
fire load
kg/km
N
N/dm
MJ/m
5.8 7.4 7.4 9.0 9.0 12.6 15.8 17.5
400 400 400 400 400 400 600 600
200 200 200 200 400 400 600 600
0.18 0.20 0.20 0.22 0.24 0.31 0.36 0.42
Order no. TB
84950867 TB600L 84950869 TB600L 84950875 TB900L 8400401L TB900L 84950479 TB900L 84950076 TB900L 8400501L TB900L 84950876 TB900L
Order no. STB
84950877 STB600 84950199 STB600 84950905 STB900 84004011 STB900 84950235 STB900 84950253 STB900 84005011 STB900 84950250 STB900
138
Office cables
Fiber Optic Cables
Breakout cable, flat
FiberConnect® I-V(ZN)HH 2x1…
outer jacket strain relief elements
84
Order no.
tight buffered or semi-tight buffered fiber
Standardisation DIN VDE 0888, part 6 and IEC 60794-2 Application
Light, thin and rugged indoor cable for use as a patch cable in distri-
subcable jacket
bution systems, as connection cable for terminals as well as for work-
ripcord
station cabling. For direct connector assembly. Construction
cable core
two single-fiber cables (TB or STB) arranged in parallel beside each other with nonmetallic strain relief elements (aramid) and halogen-free, flame-retardant subcable jacket (Ø see table)
cable jacket
halogen-free and flame-retardant material
colour of jacket
orange for multimode, yellow for singlemode
Thermal
transport and storage
–25 °C to +70 °C
properties
installation temperature –5 °C to +50 °C operating temperature
–10 °C to +70 °C
Mechanical
min. bending radius
static
35 mm
properties
(over flat side)
dynamic
65 mm
Fire
flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
performance
smoke density
IEC 61034
halogen-free
IEC 60754-1
acidity of gases
IEC 60754-2
Single element
Cable outer dimensions
mm
mm
1.7 1.8 2.0 2.1 2.5 2.8
2.8 x 4.5 2.9 x 4.7 3.1 x 5.2 3.1 x 5.2 3.7 x 6.2 4.0 x 6.8
Type
I-V(ZN)HH 2x1… I-V(ZN)HH 2x1… I-V(ZN)HH 2x1… I-V(ZN)HH 2x1… I-V(ZN)HH 2x1… I-V(ZN)HH 2x1…
Weight
max. pull force long-term
max. crush resistance long-term
kg/km
N
N/dm
MJ/m
16.5 17.5 19.0 19.0 26.0 32.0
400 400 600 600 600 600
400 400 400 400 600 600
0.58 0.60 0.63 0.63 0.65 0.83
fire load
Order no. TB
84950881 TB600L 84950882 TB600L 84950883 TB900L 84950884 TB900L 8401101L TB900L 8401201L TB900L
Order no. STB
84950887 STB600 84950886 STB600 84950885 STB900 84950168 STB900 84011011 STB900 84012011 STB900
www.leoni-fiber-optics.com
FiberConnect®
FiberTech ®
FiberSwitch ®
FiberSplit® Office cables
139
Fiber optic cables
Mini breakout cable
FiberConnect® I-V(ZN)H n…
outer jacket strain relief elements
Order no.
84 026
tight buffered or semi-tight buffered fiber
Standardisation DIN VDE 0888, part 6 and IEC 60794-2 Application
Ideal for workstation cabling due to the high flexibility and small dimensions. Non-metallic indoor cable for direct connector assembly.
Construction
cable core
tight buffered fiber (TB) or semi-tight buffered fiber (STB)
strain relief elements
non-metallic (aramid)
cable jacket
halogen-free and flame-retardant material
colour of jacket
orange for multimode, yellow for singlemode
Thermal
transport and storage
–25 °C to +70 °C
properties
installation temperature –5 °C to +50 °C operating temperature –5 °C to +70 °C
Mechanical
max. pull force
800 N
properties
max. crush resistance
500 N/dm
Fire
flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
performance
smoke density
IEC 61034
halogen-free
IEC 60754-1
acidity of gases
IEC 60754-2
No. of fibers
2 4 6 8 12 16 24
Outer Ø
Weight
min. bending radius static
min. bending radius dynamic
fire load
All mini breakout cables available
mm
kg/km
mm
mm
MJ/m
4.2 5.6 5.9 6.1 7.0 8.4 9.4
14 21 25 30 38 59 72
40 55 60 60 70 85 95
65 85 90 90 95 120 135
0.45 0.47 0.50 0.52 0.55 0.74 0.92
www.leoni-fiber-optics.com
with TB and STB buffered fibers. Order no. on request.
www.leoni-fiber-optics.com
140
Office cables
Fiber Optic Cables
Breakout cable
FiberConnect® I-V(ZN)HH n… outer jacket
Order no.
see table
strain relief elements
Standardisation DIN VDE 0888, part 6 and IEC 60794-2
tight buffered or
Application
Non-metallic, rugged cable for installation in the rising and horizontal
semi-tight buffered fiber subcable jacket
Construction
indoor area. For direct connector assembly. cable core Stranded single elements designed as tight
central strength member
buffered fiber (TB) or semi-tight buffered
ripcord
fiber (STB) with non-metallic strain relief elements (aramid) and halogen-free, cable jacket
flame-retardant subcable jacket (Ø see table) halogen-free and flame-retardant material
colour of jacket
orange for multimode, yellow for singlemode
Thermal
transport and storage
–25 °C to +70 °C
properties
installation temperature –5 °C to +50 °C operating temperature –10 °C to +70 °C
Fire
flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
performance
smoke density
IEC 61034
halogen-free
IEC 60754-1
acidity of gases
IEC 60754-2
Note
The cable is alternatively available with non-metallic rodent protection (B).
Single cable with 1.8 mm Ø, buffered fiber: TB600, tight buffered fiber with Ø 600 µm Order no. 84 015 Z No. of fibers
2 4 6 8 10 12 16 18 20 24 48
Outer Ø
Weight
mm
kg/km
6.0 6.0 6.9 8.3 9.9 11.0 10.7 11.3 11.7 12.9 17.2
35 35 47 69 105 119 106 116 129 162 245
min. bending radius static
min. bending radius dynamic
mm
mm
60 60 70 85 100 110 110 115 120 130 175
85 85 105 125 150 165 160 170 180 200 260
max. pull force long-term
max. crush resistance long-term
fire load
N
N/dm
MJ/m
800 800 800 800 800 800 800 800 800 800 800
0.63 0.63 0.89 1.22 2.01 2.37 2.03 2.27 2.54 3.11 5.43
600 600 800 800 800 800 1000 1000 1200 1200 1200
www.leoni-fiber-optics.com
FiberConnect®
FiberTech ®
FiberSwitch ®
FiberSplit®
Single cable with 2.0 mm Ø, tight buffered fiber, semi-tight buffered fiber or superstrip fiber with 900 µm Order no. No. of fibers
2 4 6 8 10 12 16 18 20 24
84 054 0 (TB)
|
Outer Ø
Weight
mm
kg/km
6.8 6.8 8.0 9.4 10.8 12.3 11.6 12.6 14.1 14.6
45 45 60 85 125 150 140 160 180 200
84 054 1 (STB)
|
min. bending radius static
84 054 6 (LB)
min. bending radius dynamic
mm
max. pull force long-term
mm
70 70 80 95 110 125 120 130 145 150
105 105 120 145 165 190 180 195 220 225
N
800 800 1000 1000 1000 1000 1000 1000 1000 1000
max. crush resistance long-term
fire load
N/dm
MJ/m
1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
1.08 1.08 1.15 1.28 1.39 1.54 1.56 1.88 2.07 2.23
Single cable with 2.1 mm Ø, tight buffered fiber, semi-tight buffered fiber or superstrip buffered fiber with Ø 900 µm Order no. No. of fibers
2 4 6 8 10 12 16 18 20 24
84 013 0 (TB)
|
84 013 1 (STB)
Outer Ø
Weight
mm
kg/km
7.0 7.0 8.2 9.6 11.0 12.5 12.0 13.0 14.5 15.0
40 45 65 95 135 155 140 160 205 210
min. bending radius static
|
84 013 6 (LB) min. bending radius dynamic
mm
mm
70 70 80 95 110 125 120 130 145 150
105 105 120 145 165 190 180 195 220 225
max. pull force long-term N
800 800 1000 1000 1000 1000 1000 1000 1000 1000
max. crush resistance long-term
fire load
N/dm
MJ/m
1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
1.10 1.10 1.18 1.31 1.42 1.57 1.62 2.00 2.10 2.35
Single cable with 25 mm Ø, tight buffered fiber, semi-tight buffered fiber or superstrip buffered fiber with Ø 900 µm Order no. No. of fibers
2 4 6 8 10 12 16 18 20 24
84 010 0 (TB)
|
84 010 1 (STB)
|
84 010 6 (LB)
Outer Ø
Weight
min. bending radius static
min. bending radius dynamic
max. pull force long-term
max. crush resistance long-term
fire load
mm
kg/km
mm
mm
N
N/dm
MJ/m
115 115 135 165 195 215 210 215 240 260
800 800 1200 1200 1200 1200 1200 1200 1200 1200
1500 1500 1500 1500 1500 1500 1500 1500 1500 1500
1.20 1.20 1.36 1.52 1.68 1.80 1.84 1.92 2.16 2.48
7.5 7.5 9.0 11.0 13.0 14.5 14.0 14.5 16.0 17.0
www.leoni-fiber-optics.com
45 50 75 110 160 182 160 175 225 245
75 75 90 110 130 145 140 145 160 175
141
Fiber optic cables
Office cables
142
Office cables
Fiber Optic Cables
Indoor cable for multifiber connectors
FiberConnect® I-F(ZN)HH n …
outer jacket fibers
Order no.
84 071
strain relief elements
Standardisation according to DIN VDE 0888-6 and IEC 60794-2 Application
For fixed installation in cable ducts and conduits as well as for shunting purposes. Suitable for direct connector assembly on MTP®connectors/MP0® connector suitable.
Construction
cable core
(2–24) optical fibers
strain relief elements
non-metallic (aramid)
cable jacket
halogen-free and flame-retardant material
colour of jacket
orange for multimode, yellow for singlemode
Thermal
transport and storage
–25 °C to +70 °C
properties
installation temperature –5 °C to +50 °C operating temperature –10 °C to +70 °C
Mechanical
min. bending radius
properties
static
15 x outer diameter
dynamic
20 x outer diameter
max. crush resistance
150 N/dm
Fire
flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
performance
smoke density
IEC 61034
halogen-free
IEC 60754-1
acidity of gases
IEC 60754-2
Max. no. of fibers
8 12 24
Outer Ø
Wall thickness
Weight
max. pull force
Fire load
mm
mm
2.8 3.0 4.5
0.5 0.5 1.0
kg/km
N
MJ/m
7 8 18
300 300 450
0.12 0.14 0.31
www.leoni-fiber-optics.com
FiberConnect®
FiberTech ®
FiberSwitch ®
FiberSplit® Office cables
143
Fiber optic cables
Indoor cable for multifiber connectors
outer jacket
FiberConnect® I-F(ZN)HH nxm … 3.0
fleece subcable jacket
Order no.
84 021
ripcord GFR central strength member
Standardisation according to DIN VDE 0888-6 and IEC 60794-2 Applicaton
Splittable indoor cable for fixed installation in cable ducts
strain relief
and conduits. Suitable for direct connector assembly on
fibers
MTP®connectors/MPO®connector suitable. Construction
cable core
Glass fiber-reinforced central strength member in the core, over that single elements stranded in layers (2 12) 12 optical fibers per single element with Ø 3.0 mm
Strain relief elements
non-metallic (aramid)
cable jacket
halogen-free and flame-retardant material
colour of jacket
orange
Thermal
transport and storage
–25 °C to +70 °C
properties
installation temperature
–5 °C to +50 °C
operating temperature
–10 °C to +70 °C
min. bending radius
static
15 x outer diameter
dynamic
20 x outer diameter
Mechanical properties
max. crush resistance
1000 N/dm
Fire
flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
performance
smoke density
IEC 61034
halogen-free
IEC 60754-1
acidity of gases
IEC 60754-2
Single elements
Outer Ø
Wall thickness
Weight
max. pull force
mm
mm
kg/km
N
2 4 6 8 10 12
8.9 8.9 10.8 13.1 14.6 16.5
0.8 0.8 0.8 0.9 0.9 0.9
70 70 100 150 185 230
www.leoni-fiber-optics.com
800 800 1000 1000 1000 1000
Fire load MJ/m
1.16 1.16 1.71 2.57 3.69 4.96
144
Office cables
Fiber Optic Cables
Breakout cable with central strength member
outer jacket
FiberConnect® AT-VQ(ZN)HH n … 2.1
fleece gel-free loose tube
Order no.
84 213
GFR central strength member strain relief elements
Standardisation according to DIN VDE 0888-6 and IEC 60794-2 Application Construction
Splittable outdoor cable for fixed installation in cable ducts and
and rodent protection
conduits. For direct connector assembly.
ripcord
cable core
Glass fiber-reinforced central strength member in the core, over that single elements designed as tight buffered fiber (TB) and semi-tight buffered fiber (STB) gel-filled with non-metallic strain relief elements (aramid) and halogen-free, flame-retardant subcable jacket (Ø 2.1 mm), stranded in layers (2 24)
cable jacket
halogen-free and flame-retardant material
colour of jacket
orange for multimode, yellow for singlemode
Thermal
transport and storage
–25 °C to +70 °C
properties
Verlegung
–5 °C to +50 °C
operating temperature –25 °C to +70 °C Mechanical
min. bending radius
properties max. crush resistance
static
10 x outer diameter
dynamic
15 x outer diameter
1000 N/dm
Fire
flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
performance
smoke density
IEC 61034
halogen-free
IEC 60754-1
acidity of gases
IEC 60754-2
No. of fibers
2 4 6 8 10 12 16 18 20 24 26 36
Outer Ø
Wall thickness
Weight
Fire load
Pull force
mm
mm
kg/km
MJ/m
MJ/m
7.0 7.0 8.2 9.6 11.0 12.5 12.0 13.0 14.5 15.0 15.5 15.5
0.9 0.9 0.9 0.9 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.1
40 45 65 95 135 135 140 160 205 210 225 300
1.10 1.10 1.18 1.31 1.42 1.57 1.62 2.00 2.10 2.35 2.45 3.89
800 800 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 www.leoni-fiber-optics.com