30
Office Cables
Fiber Optic Cables
Simplex cable
FiberConnect® I-V(ZN)H 1…
Outer jacket Strain relief elements
Order no.
Tight buffered or semi-tight
84 003
buffered fiber
Standardisation DIN VDE 0888, Part 4 and IEC 60 794-2 Application
Ideal for use as a patch cable in distribution systems as well as for connecting terminals due to the high flexibility and small diameter
Construction
Cable core
Tight buffered fiber (TB), semi-tight buffered fiber (STB) or superstrip (LB)
Strain relief elements
Non-metallic (aramid)
Cable jacket
Halogen-free and flame-retardant material
Colour of jacket
Orange for multimode, yellow for singlemode ➔ other colours possible
Thermal properties
Transport and storage
–25°C to +70°C
Installation
–5°C to +50°C
Operation
–10°C to +70°C
Mechanical properties
min. bending radius
static dynamic
Fire performance
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
Smoke density
IEC 61034
Halogen-free
IEC 60754-2
30 mm 60 mm
No corrosive and toxic fumes
Outer Ø
Type
mm
1.6 1.8 2 2.1 2.4 2.8 2.9 3 3.4
I-V(ZN)H 1… I-V(ZN)H 1… I-V(ZN)H 1… I-V(ZN)H 1… I-V(ZN)H 1…* I-V(ZN)H 1… I-V(ZN)H 1… I-V(ZN)H 1… I-V(ZN)H 1…*
Weight
Max. pull force long-term
Max. crush resistance long-term
Fire load
kg/km
N
N/dm
MJ/m
200 200 300 300 400 400 400 400 400
100 100 100 100 150 150 150 150 150
0.09 0.10 0.11 0.12 0.16 0.18 0.20 0.21 0.32
2.9 3.7 5.0 5.1 5.7 7.9 8.0 8.1 12.0
All simplex cables available with TB, STB and LB buffered fibers. Order no. on request.
* acc. to TS 0011/96 Deutsche Telekom
www.leoni-fiber-optics.com
FiberConnect®
FiberTech®
FiberSwitch®
FiberSplit® Office Cables
31
FO Cables
Duplex cable
FiberConnect® I-V(ZN)H 2x1…
Outer jacket Strain relief elements
Order no.
Tight buffered or semi-tight
84 005
buffered fiber
Standardisation DIN VDE 0888, Part 6 and IEC 60 794-2 Application
Ideal for use as a patch cable in distribution systems as well as for connecting terminals due to the high flexibility and small diameter
Construction
Cable core
Tight buffered fiber (TB), semi-tight buffered fiber (STB) or superstrip (LB)
Strain relief elements
Non-metallic (aramid)
Cable jacket
Halogen-free and flame-retardant material
Colour of jacket
Orange for multimode, yellow for singlemode ➔ other colours possible
Transport and storage
–25°C to +70°C
Installation
–5°C to +50°C
Operation
–10°C to +70°C
Mechanical properties
min. bending radius
static dynamic
Fire performance
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
Smoke density
IEC 61034
Halogen-free
IEC 60754-2
Thermal properties
30 mm 60 mm
No corrosive and toxic fumes
Outer Ø
Type
mm
1.6 x 3.3 1.8 x 3.7 2.0 x 4.1 2.1 x 4.3 2.4 x 4.9 2.8 x 5.7 3.0 x 6.1
I-V(ZN)H 2x1… I-V(ZN)H 2x1… I-V(ZN)H 2x1… I-V(ZN)H 2x1… I-V(ZN)H 2x1… I-V(ZN)H 2x1… I-V(ZN)H 2x1…
www.leoni-fiber-optics.com
Weight
Max. pull force long-term
Max. crush resistance long-term
Fire load
kg/km
N
N/dm
MJ/m
5.8 7.4 9.0 9.0 12.6 15.8 17.5
400 400 400 400 400 600 600
200 200 200 400 400 600 600
0.18 0.20 0.22 0.24 0.32 0.36 0.42
All duplex cables available with TB, STB and LB buffered fibers. Order no. on request.
32
Office Cables
Fiber Optic Cables
Mini breakout cable
FiberConnect® I-V(ZN)H n…
Outer jacket Strain relief elements
Order no.
Tight buffered or semi-tight
84 026
buffered fiber
Standardisation DIN VDE 0888, Part 6 and IEC 60 794-2 Application
Ideal for workstation cabling due to the high flexibility and small dimensions. Non-metallic indoor cable for direct connector assembly.
Construction
Cable core
Tight buffered fiber (TB), semi-tight buffered fiber (STB) or superstrip (LB)
Strain relief elements
Non-metallic (aramid)
Cable jacket
Halogen-free and flame-retardant material
Colour of jacket
Orange for multimode, yellow for singlemode
Transport and storage
–25°C to +70°C
Installation
–5°C to +50°C
Operation
–10°C to +70°C
Mechanical properties
max. pull force max. crush resistance
long-term long-term
Fire performance
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
Smoke density
IEC 61034
Halogen-free
IEC 60754-2
Thermal properties
800 N 300 N/dm
No corrosive and toxic fumes
Number of fibers
2 4 6 8 12 16 24
Outer Ø
Weight
Min. bending radius static
Min. bending radius dynamic
Fire load
mm
kg/km
mm
mm
MJ/m
4.2 5.6 5.9 6.1 7.0 8.4 9.4
14 21 25 30 38 59 72
40 55 60 60 70 85 95
65 85 90 90 95 120 135
0.45 0.47 0.50 0.52 0.55 0.74 0.92
All mini breakout cables available with TB, STB and LB buffered fibers. Order no. on request.
www.leoni-fiber-optics.com
FiberConnect®
FiberTech®
FiberSwitch®
FiberSplit® Office Cables
33
FO Cables
Breakout cable, flat
FiberConnect® I-V(ZN)HH 2x1…
Outer jacket Strain relief elements
Order no.
Tight buffered or semi-tight
84 011
buffered fiber
Standardisation DIN VDE 0888, Part 6 and IEC 60 794-2 Application
Light, thin and rugged indoor cable for use as a patch cable in distribution systems, as connection cable for terminals as well as for workstation cabling. For direct connector assembly.
Construction
Cable core
Two single-fiber cables (TB, STB or LB) arranged in parallel beside each other with non-metallic strain relief elements (aramid) and halogen-free, flame-retardant subcable jacket (Ø see table)
Cable jacket
Halogen-free and flame-retardant material
Colour of jacket
Orange for multimode, yellow for singlemode
Transport and storage
–25°C to +70°C
Installation
–5°C to +50°C
Operation
–10°C to +70°C
Mechanical properties
min. bending radius (over flat side)
static dynamic
Fire performance
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
Smoke density
IEC 61034
Halogen-free
IEC 60754-2
Thermal properties
Subcable jacket
35 mm 65 mm
No corrosive and toxic fumes
Single element
Cable outer dimensions
mm
mm
1.7 1.8 2.0 2.1 2.5 2.8
2.8 x 4.5 2.9 x 4.7 3.1 x 5.2 3.1 x 5.2 3.7 x 6.2 4.0 x 6.8
www.leoni-fiber-optics.com
Type
I-V(ZN)HH 2x1… I-V(ZN)HH 2x1… I-V(ZN)HH 2x1… I-V(ZN)HH 2x1… I-V(ZN)HH 2x1… I-V(ZN)HH 2x1…
Weight
Max. pull force long-term
Max. crush resistance long-term
Fire load
kg/km
N
N/dm
MJ/m
16.5 17.5 19.0 19.0 26.0 32.0
400 400 600 600 600 600
400 400 400 400 600 600
0.58 0.60 0.63 0.63 0.65 0.83
All flat breakout cables available with TB, STB and LB buffered fibers. Order no. on request.
34
Office Cables
Fiber Optic Cables
Breakout cable
FiberConnect® I-V(ZN)HH n… Outer jacket
Order no. See table Standardisation DIN VDE 0888, Part 6 and IEC 60 794-2 Application Non-metallic, rugged cable for installation in the rising and horizontal indoor area. For direct connector assembly. Construction Cable core Stranded single elements designed as tight buffered fiber (TB), semi-tight buffered fiber (STB) or superstrip (LB) with non-metallic strain relief elements (aramid) and halogen-free, flame-retardant subcable jacket (Ø see table) Cable jacket Halogen-free and flame-retardant material Colour of jacket Orange for multimode, yellow for singlemode Thermal Transport and storage –25°C to +70°C properties Installation –5°C to +50°C Fire performance
Operation Flame retardancy
–10°C to +70°C IEC 60332-1-2 and IEC 60332-3-22 Cat. A
Smoke density
IEC 61034
Halogen-free
IEC 60754-2
Strain relief elements Tight buffered or semi-tight buffered fiber Subcable jacket
No corrosive and toxic fumes Note
The cable is alternatively available with non-metallic rodent protection (B).
Single cable with 1.8 mm Ø, buffered fiber: TB600, tight buffered fiber with Ø 600 µm Order no. 84 015 Z Number of fibers
Outer Ø
Weight
mm
kg/km
2 4 6 8 10 12 16 18
6.0 6.0 6.9 8.3 9.9 11.0 10.7 11.3
35 35 47 69 105 119 106 116
Min. bending radius Min. bending radius static dynamic mm
60 60 70 85 100 110 110 115
Max. pull force long-term
Max. crush resistance long-term
Fire load
mm
N
N/dm
MJ/m
85 85 105 125 150 165 160 170
600 600 800 800 800 800 1000 1000
800 800 800 800 800 800 800 800
0.63 0.63 0.89 1.22 2.01 2.37 2.03 2.27
www.leoni-fiber-optics.com
FiberConnect®
FiberTech®
FiberSwitch®
FiberSplit®
Single cable with 2.0 mm Ø, tight buffered fiber, semi-tight buffered fiber or superstrip fiber with 900 µm Order no. 84 054 0 (TB) | 84 054 1 (STB) | 84 054 6 (LB) Number of fibers
2 4 6 8 10 12 16 18 20 24
Outer Ø
Weight
mm
kg/km
6.8 6.8 8.0 9.4 10.8 12.3 11.6 12.6 14.1 14.6
45 45 60 85 125 150 140 160 180 200
Min. bending radius Min. bending radius static dynamic mm
70 70 80 95 110 125 120 130 145 150
Max. pull force long-term
Max. crush resistance long-term
mm
N
N/dm
105 105 120 145 165 190 180 195 220 225
800 800 1000 1000 1000 1000 1000 1000 1000 1000
1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
Fire load MJ/m
1.08 1.08 1.15 1.28 1.39 1.54 1.56 1.88 2.07 2.23
Single cable with 2.1 mm Ø, tight buffered fiber, semi-tight buffered fiber or superstrip buffered fiber with Ø 900 µm Order no. 84 013 0 (TB) | 84 013 1 (STB) | 84 013 6 (LB) Number of fibers
2 4 6 8 10 12 16 18 20 24
Outer Ø
Weight
mm
kg/km
7.0 7.0 8.2 9.6 11.0 12.5 12.0 13.0 14.5 15.0
40 45 65 95 135 155 140 160 205 210
Min. bending radius Min. bending radius static dynamic mm
70 70 80 95 110 125 120 130 145 150
Max. pull force long-term
Max. crush resistance long-term
Fire load
mm
N
N/dm
MJ/m
105 105 120 145 165 190 180 195 220 225
800 800 1000 1000 1000 1000 1000 1000 1000 1000
1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
1.10 1.10 1.18 1.31 1.42 1.57 1.62 2.00 2.10 2.35
Single cable with 2.5 mm Ø, buffered fiber: TB900 or STB900, tight buffered fiber, semi-tight buffered fiber or superstrip buffered fiber with Ø 900 µm Order no. 84 010 0 (TB) | 84 010 1 (STB) | 84 010 6 (LB) Number of fibers
2 4 6 8 10 12 16 18 20 24
Outer Ø
Weight
mm
kg/km
7.5 7.5 9.0 11.0 13.0 14.5 14.0 14.5 16.0 17.0
www.leoni-fiber-optics.com
45 50 75 110 160 182 160 175 225 245
Min. bending radius Min. bending radius static dynamic mm
75 75 90 110 130 145 140 145 160 175
Max. pull force long-term
35
FO Cables
Office Cables
Max. crush resistance long-term
Fire load
mm
N
N/dm
MJ/m
115 115 135 165 195 215 210 215 240 260
800 800 1200 1200 1200 1200 1200 1200 1200 1200
1500 1500 1500 1500 1500 1500 1500 1500 1500 1500
1.20 1.20 1.36 1.52 1.68 1.80 1.84 1.92 2.16 2.48
36
Office Cables
Fiber Optic Cables
Indoor cable with central, gel-free loose tube
FiberConnect® I-D(ZN)BH n… JF
Outer jacket Gel-free loose tube
Order no.
Strain relief elements and rodent
84 050
protection
Standardisation DIN VDE 0888, Part 6 and IEC 60 794-2 Application
Light and flexible cable, can be used inside buildings. Gel-free loose tubes mean the fibers do not need to be cleaned. Installation in cable ducts, on cable trays or in cable conduits. Especially suited for rising areas.
Construction
Cable core
Gel-free loose tubes with max. 24 fibers
Armour
Multi-functional E-glass yarn, water-absorbent as strain relief and rodent protection
Cable jacket
Halogen-free and flame-retardant material
Colour of jacket
Orange for multimode, yellow for singlemode
Transport and storage
–25°C to +70°C
Installation
–5°C to +50°C
Operation
–10°C to +60°C
min. bending radius
static dynamic
15 x outside diameter 20 x outside diameter
max. pull force
long-term
600 N
max. crush resistance
long-term
1500 N/dm
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
Smoke density
IEC 61034
Halogen-free
IEC 60754-2
Thermal properties Mechanical properties
Fire performance
No corrosive and toxic fumes
Number of fibers
12 24
Outer Ø
Weight
Fire load
mm
kg/km
MJ/m
6.3 6.8
44 49
0.68 0.76
www.leoni-fiber-optics.com
FiberConnect®
FiberTech®
FiberSwitch®
FiberSplit® Office Cables
37
FO Cables
Indoor cable with stranded, gel-free loose tubes
FiberConnect® I-D(ZN)H nxm… JF
Outer jacket Gel-free loose tube
Order no.
Ripcord
84 048
GFR central strength member
Standardisation DIN VDE 0888, Part 6 and IEC 60 794-2
Strain relief elements
Application
Cable for use inside buildings. Gel-free loose tubes mean the fibers do not need to be cleaned. Installation in cable ducts, on cable trays or in cable conduits. Especially suited to rising areas.
Construction
Cable core
Glass fiber-reinforced central strength member with strand elements, designed as gel-free loose tubes and if applicable bundle elements
Strain relief elements
Non-metallic (aramid)
Cable jacket
Halogen-free and flame-retardant material
Colour of jacket
Orange for multimode, yellow for singlemode
Transport and storage
–25°C to +70°C
Installation
–5°C to +50°C
Operation
–10°C to +60°C
min. bending radius
static dynamic
15 x outside diameter 20 x outside diameter
max. pull force
long-term
1000 N
max. crush resistance
long-term
2000 N/dm
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
Smoke density
IEC 61034
Halogen-free
IEC 60754-2
Thermal properties Mechanical properties
Fire performance
No corrosive and toxic fumes Number of tubes
1xm 2xm 3xm 4xm 5xm 6xm 8xm 10 x m 12 x m
Number of fibers
12 24 36 48 60 72 96 120 144
www.leoni-fiber-optics.com
Outer Ø
Weight
Fire load
mm
kg/km
MJ/m
10.5 10.5 10.5 10.5 10.5 11.6 13.1 14.8 16.3
95 95 95 95 95 115 135 175 215
2.00 2.00 2.00 2.00 2.00 2.36 2.48 3.12 3.76
ide use ins r o f s e l s al c ab e con u n i ve r se tub o d o n l i f h l t l i w uc tion You wi ildings constr u r b e b e i f d i d ts . uf fere and ou c ables tig ht b r o n td o o r o u i t o c n u o r t s h a p te r nex t c in the