Office Cables

Fiber Optic Cables

Simplex cable

FiberConnect® I-V(ZN)H 1…

Outer jacket Strain relief elements

Order no.

Tight buffered or semi-tight

84 003   

buffered fiber

Standardisation DIN VDE 0888, Part 4 and IEC 60 794-2 Application

Ideal for use as a patch cable in distribution systems as well as for connecting terminals due to the high flexibility and small diameter

Construction

Cable core

Tight buffered fiber (TB), semi-tight buffered fiber (STB) or superstrip (LB)

Strain relief elements

Non-metallic (aramid)

Cable jacket

Halogen-free and flame-retardant material

Colour of jacket

Orange for multimode, yellow for singlemode ➔ other colours possible

Thermal properties

Transport and storage

–25°C to +70°C

Installation

–5°C to +50°C

Operation

–10°C to +70°C

Mechanical properties

min. bending radius

static dynamic

Fire performance

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Smoke density

IEC 61034

Halogen-free

IEC 60754-2

30 mm 60 mm

No corrosive and toxic fumes

Outer Ø

Type

mm

1.6 1.8 2 2.1 2.4 2.8 2.9 3 3.4

I-V(ZN)H 1… I-V(ZN)H 1… I-V(ZN)H 1… I-V(ZN)H 1… I-V(ZN)H 1…* I-V(ZN)H 1… I-V(ZN)H 1… I-V(ZN)H 1… I-V(ZN)H 1…*

Weight

Max. pull force long-term

Max. crush resistance long-term

Fire load

kg/km

N

N/dm

MJ/m

200 200 300 300 400 400 400 400 400

100 100 100 100 150 150 150 150 150

0.09 0.10 0.11 0.12 0.16 0.18 0.20 0.21 0.32

2.9 3.7 5.0 5.1 5.7 7.9 8.0 8.1 12.0

All simplex cables available with TB, STB and LB buffered fibers. Order no. on request.

* acc. to TS 0011/96 Deutsche Telekom

www.leoni-fiber-optics.com


FiberConnect®

FiberTech®

FiberSwitch®

FiberSplit® Office Cables

31

FO Cables

Duplex cable

FiberConnect® I-V(ZN)H 2x1…

Outer jacket Strain relief elements

Order no.

Tight buffered or semi-tight

84 005   

buffered fiber

Standardisation DIN VDE 0888, Part 6 and IEC 60 794-2 Application

Ideal for use as a patch cable in distribution systems as well as for connecting terminals due to the high flexibility and small diameter

Construction

Cable core

Tight buffered fiber (TB), semi-tight buffered fiber (STB) or superstrip (LB)

Strain relief elements

Non-metallic (aramid)

Cable jacket

Halogen-free and flame-retardant material

Colour of jacket

Orange for multimode, yellow for singlemode ➔ other colours possible

Transport and storage

–25°C to +70°C

Installation

–5°C to +50°C

Operation

–10°C to +70°C

Mechanical properties

min. bending radius

static dynamic

Fire performance

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Smoke density

IEC 61034

Halogen-free

IEC 60754-2

Thermal properties

30 mm 60 mm

No corrosive and toxic fumes

Outer Ø

Type

mm

1.6 x 3.3 1.8 x 3.7 2.0 x 4.1 2.1 x 4.3 2.4 x 4.9 2.8 x 5.7 3.0 x 6.1

I-V(ZN)H 2x1… I-V(ZN)H 2x1… I-V(ZN)H 2x1… I-V(ZN)H 2x1… I-V(ZN)H 2x1… I-V(ZN)H 2x1… I-V(ZN)H 2x1…

www.leoni-fiber-optics.com

Weight

Max. pull force long-term

Max. crush resistance long-term

Fire load

kg/km

N

N/dm

MJ/m

5.8 7.4 9.0 9.0 12.6 15.8 17.5

400 400 400 400 400 600 600

200 200 200 400 400 600 600

0.18 0.20 0.22 0.24 0.32 0.36 0.42

All duplex cables available with TB, STB and LB buffered fibers. Order no. on request.


32

Office Cables

Fiber Optic Cables

Mini breakout cable

FiberConnect® I-V(ZN)H n…

Outer jacket Strain relief elements

Order no.

Tight buffered or semi-tight

84 026   

buffered fiber

Standardisation DIN VDE 0888, Part 6 and IEC 60 794-2 Application

Ideal for workstation cabling due to the high flexibility and small dimensions. Non-metallic indoor cable for direct connector assembly.

Construction

Cable core

Tight buffered fiber (TB), semi-tight buffered fiber (STB) or superstrip (LB)

Strain relief elements

Non-metallic (aramid)

Cable jacket

Halogen-free and flame-retardant material

Colour of jacket

Orange for multimode, yellow for singlemode

Transport and storage

–25°C to +70°C

Installation

–5°C to +50°C

Operation

–10°C to +70°C

Mechanical properties

max. pull force max. crush resistance

long-term long-term

Fire performance

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Smoke density

IEC 61034

Halogen-free

IEC 60754-2

Thermal properties

800 N 300 N/dm

No corrosive and toxic fumes

Number of fibers

2 4 6 8 12 16 24

Outer Ø

Weight

Min. bending radius static

Min. bending radius dynamic

Fire load

mm

kg/km

mm

mm

MJ/m

4.2 5.6 5.9 6.1 7.0 8.4 9.4

14 21 25 30 38 59 72

40 55 60 60 70 85 95

65 85 90 90 95 120 135

0.45 0.47 0.50 0.52 0.55 0.74 0.92

All mini breakout cables available with TB, STB and LB buffered fibers. Order no. on request.

www.leoni-fiber-optics.com


FiberConnect®

FiberTech®

FiberSwitch®

FiberSplit® Office Cables

33

FO Cables

Breakout cable, flat

FiberConnect® I-V(ZN)HH 2x1…

Outer jacket Strain relief elements

Order no.

Tight buffered or semi-tight

84 011   

buffered fiber

Standardisation DIN VDE 0888, Part 6 and IEC 60 794-2 Application

Light, thin and rugged indoor cable for use as a patch cable in distribution systems, as connection cable for terminals as well as for workstation cabling. For direct connector assembly.

Construction

Cable core

Two single-fiber cables (TB, STB or LB) arranged in parallel beside each other with non-metallic strain relief elements (aramid) and halogen-free, flame-retardant subcable jacket (Ø see table)

Cable jacket

Halogen-free and flame-retardant material

Colour of jacket

Orange for multimode, yellow for singlemode

Transport and storage

–25°C to +70°C

Installation

–5°C to +50°C

Operation

–10°C to +70°C

Mechanical properties

min. bending radius (over flat side)

static dynamic

Fire performance

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Smoke density

IEC 61034

Halogen-free

IEC 60754-2

Thermal properties

Subcable jacket

35 mm 65 mm

No corrosive and toxic fumes

Single element

Cable outer dimensions

mm

mm

1.7 1.8 2.0 2.1 2.5 2.8

2.8 x 4.5 2.9 x 4.7 3.1 x 5.2 3.1 x 5.2 3.7 x 6.2 4.0 x 6.8

www.leoni-fiber-optics.com

Type

I-V(ZN)HH 2x1… I-V(ZN)HH 2x1… I-V(ZN)HH 2x1… I-V(ZN)HH 2x1… I-V(ZN)HH 2x1… I-V(ZN)HH 2x1…

Weight

Max. pull force long-term

Max. crush resistance long-term

Fire load

kg/km

N

N/dm

MJ/m

16.5 17.5 19.0 19.0 26.0 32.0

400 400 600 600 600 600

400 400 400 400 600 600

0.58 0.60 0.63 0.63 0.65 0.83

All flat breakout cables available with TB, STB and LB buffered fibers. Order no. on request.


34

Office Cables

Fiber Optic Cables

Breakout cable

FiberConnect® I-V(ZN)HH n… Outer jacket

Order no. See table Standardisation DIN VDE 0888, Part 6 and IEC 60 794-2 Application Non-metallic, rugged cable for installation in the rising and horizontal indoor area. For direct connector assembly. Construction Cable core Stranded single elements designed as tight buffered fiber (TB), semi-tight buffered fiber (STB) or superstrip (LB) with non-metallic strain relief elements (aramid) and halogen-free, flame-retardant subcable jacket (Ø see table) Cable jacket Halogen-free and flame-retardant material Colour of jacket Orange for multimode, yellow for singlemode Thermal Transport and storage –25°C to +70°C properties Installation –5°C to +50°C Fire performance

Operation Flame retardancy

–10°C to +70°C IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Smoke density

IEC 61034

Halogen-free

IEC 60754-2

Strain relief elements Tight buffered or semi-tight buffered fiber Subcable jacket

No corrosive and toxic fumes Note

The cable is alternatively available with non-metallic rodent protection (B).

Single cable with 1.8 mm Ø, buffered fiber: TB600, tight buffered fiber with Ø 600 µm Order no. 84 015  Z  Number of fibers

Outer Ø

Weight

mm

kg/km

2 4 6 8 10 12 16 18

6.0 6.0 6.9 8.3 9.9 11.0 10.7 11.3

35 35 47 69 105 119 106 116

Min. bending radius Min. bending radius static dynamic mm

60 60 70 85 100 110 110 115

Max. pull force long-term

Max. crush resistance long-term

Fire load

mm

N

N/dm

MJ/m

85 85 105 125 150 165 160 170

600 600 800 800 800 800 1000 1000

800 800 800 800 800 800 800 800

0.63 0.63 0.89 1.22 2.01 2.37 2.03 2.27

www.leoni-fiber-optics.com


FiberConnect®

FiberTech®

FiberSwitch®

FiberSplit®

Single cable with 2.0 mm Ø, tight buffered fiber, semi-tight buffered fiber or superstrip fiber with 900 µm Order no. 84 054  0  (TB) | 84 054  1  (STB) | 84 054  6  (LB) Number of fibers

2 4 6 8 10 12 16 18 20 24

Outer Ø

Weight

mm

kg/km

6.8 6.8 8.0 9.4 10.8 12.3 11.6 12.6 14.1 14.6

45 45 60 85 125 150 140 160 180 200

Min. bending radius Min. bending radius static dynamic mm

70 70 80 95 110 125 120 130 145 150

Max. pull force long-term

Max. crush resistance long-term

mm

N

N/dm

105 105 120 145 165 190 180 195 220 225

800 800 1000 1000 1000 1000 1000 1000 1000 1000

1000 1000 1000 1000 1000 1000 1000 1000 1000 1000

Fire load MJ/m

1.08 1.08 1.15 1.28 1.39 1.54 1.56 1.88 2.07 2.23

Single cable with 2.1 mm Ø, tight buffered fiber, semi-tight buffered fiber or superstrip buffered fiber with Ø 900 µm Order no. 84 013  0  (TB) | 84 013  1  (STB) | 84 013  6  (LB) Number of fibers

2 4 6 8 10 12 16 18 20 24

Outer Ø

Weight

mm

kg/km

7.0 7.0 8.2 9.6 11.0 12.5 12.0 13.0 14.5 15.0

40 45 65 95 135 155 140 160 205 210

Min. bending radius Min. bending radius static dynamic mm

70 70 80 95 110 125 120 130 145 150

Max. pull force long-term

Max. crush resistance long-term

Fire load

mm

N

N/dm

MJ/m

105 105 120 145 165 190 180 195 220 225

800 800 1000 1000 1000 1000 1000 1000 1000 1000

1000 1000 1000 1000 1000 1000 1000 1000 1000 1000

1.10 1.10 1.18 1.31 1.42 1.57 1.62 2.00 2.10 2.35

Single cable with 2.5 mm Ø, buffered fiber: TB900 or STB900, tight buffered fiber, semi-tight buffered fiber or superstrip buffered fiber with Ø 900 µm Order no. 84 010  0  (TB) | 84 010  1  (STB) | 84 010  6  (LB) Number of fibers

2 4 6 8 10 12 16 18 20 24

Outer Ø

Weight

mm

kg/km

7.5 7.5 9.0 11.0 13.0 14.5 14.0 14.5 16.0 17.0

www.leoni-fiber-optics.com

45 50 75 110 160 182 160 175 225 245

Min. bending radius Min. bending radius static dynamic mm

75 75 90 110 130 145 140 145 160 175

Max. pull force long-term

35

FO Cables

Office Cables

Max. crush resistance long-term

Fire load

mm

N

N/dm

MJ/m

115 115 135 165 195 215 210 215 240 260

800 800 1200 1200 1200 1200 1200 1200 1200 1200

1500 1500 1500 1500 1500 1500 1500 1500 1500 1500

1.20 1.20 1.36 1.52 1.68 1.80 1.84 1.92 2.16 2.48


36

Office Cables

Fiber Optic Cables

Indoor cable with central, gel-free loose tube

FiberConnect® I-D(ZN)BH n… JF

Outer jacket Gel-free loose tube

Order no.

Strain relief elements and rodent

84 050   

protection

Standardisation DIN VDE 0888, Part 6 and IEC 60 794-2 Application

Light and flexible cable, can be used inside buildings. Gel-free loose tubes mean the fibers do not need to be cleaned. Installation in cable ducts, on cable trays or in cable conduits. Especially suited for rising areas.

Construction

Cable core

Gel-free loose tubes with max. 24 fibers

Armour

Multi-functional E-glass yarn, water-absorbent as strain relief and rodent protection

Cable jacket

Halogen-free and flame-retardant material

Colour of jacket

Orange for multimode, yellow for singlemode

Transport and storage

–25°C to +70°C

Installation

–5°C to +50°C

Operation

–10°C to +60°C

min. bending radius

static dynamic

15 x outside diameter 20 x outside diameter

max. pull force

long-term

600 N

max. crush resistance

long-term

1500 N/dm

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Smoke density

IEC 61034

Halogen-free

IEC 60754-2

Thermal properties Mechanical properties

Fire performance

No corrosive and toxic fumes

Number of fibers

12 24

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

6.3 6.8

44 49

0.68 0.76

www.leoni-fiber-optics.com


FiberConnect®

FiberTech®

FiberSwitch®

FiberSplit® Office Cables

37

FO Cables

Indoor cable with stranded, gel-free loose tubes

FiberConnect® I-D(ZN)H nxm… JF

Outer jacket Gel-free loose tube

Order no.

Ripcord

84 048   

GFR central strength member

Standardisation DIN VDE 0888, Part 6 and IEC 60 794-2

Strain relief elements

Application

Cable for use inside buildings. Gel-free loose tubes mean the fibers do not need to be cleaned. Installation in cable ducts, on cable trays or in cable conduits. Especially suited to rising areas.

Construction

Cable core

Glass fiber-reinforced central strength member with strand elements, designed as gel-free loose tubes and if applicable bundle elements

Strain relief elements

Non-metallic (aramid)

Cable jacket

Halogen-free and flame-retardant material

Colour of jacket

Orange for multimode, yellow for singlemode

Transport and storage

–25°C to +70°C

Installation

–5°C to +50°C

Operation

–10°C to +60°C

min. bending radius

static dynamic

15 x outside diameter 20 x outside diameter

max. pull force

long-term

1000 N

max. crush resistance

long-term

2000 N/dm

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Smoke density

IEC 61034

Halogen-free

IEC 60754-2

Thermal properties Mechanical properties

Fire performance

No corrosive and toxic fumes Number of tubes

1xm 2xm 3xm 4xm 5xm 6xm 8xm 10 x m 12 x m

Number of fibers

12 24 36 48 60 72 96 120 144

www.leoni-fiber-optics.com

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

10.5 10.5 10.5 10.5 10.5 11.6 13.1 14.8 16.3

95 95 95 95 95 115 135 175 215

2.00 2.00 2.00 2.00 2.00 2.36 2.48 3.12 3.76

ide use ins r o f s e l s al c ab e con u n i ve r se tub o d o n l i f h l t l i w uc tion You wi ildings constr u r b e b e i f d i d ts . uf fere and ou c ables tig ht b r o n td o o r o u i t o c n u o r t s h a p te r nex t c in the