FiberSplit® Outdoor Cables

39

FO Cables

Universal cable with system integrity

Rodent-protected universal cable with central loose tube (2500 N) and system integrity in the event of fire

FiberConnect® U-D(ZN)BH n…2500 N

Outer jacket Central loose tube, gel-filled Ripcord

84 040   

Order no.

Inner fire protection tape

Standardisation DIN VDE 0888, Part 6 Application

Non-metallic, light and flexible cable with increased tensile strength that can be used both inside and outside buildings. Installation in cable ducts, on cable trays or in cable conduits.

Construction

Cable core

Strain relief and rodent protection

Loose tube, gel-filled

Inner fire protection tape

Thermal properties Mechanical properties

Fire performance

Armour

Multi-functional, strengthened E-glass yarn, water-absorbent as non-metallic strain relief elements and rodent protection

Cable jacket

Halogen-free and flame-retardant material

Colour of jacket

Blue

Transport and storage

–25°C to +70°C

Installation

–5°C to +50°C

Operation

–20°C to +60°C

min. bending radius

static dynamic

15 x outside diameter 20 x outside diameter

max. pull force

long-term

2500 N

max. crush resistance

long-term

3000 N/dm

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Smoke density

IEC 61034

Halogen-free

IEC 60754-2

No corrosive and toxic fumes System Acc. to IEC 60 331-11, IEC 60 331-25 and EN 50200 integrity test 90 min (VDE test report)

Max. number of fibers

12 24

www.leoni-fiber-optics.com

ty integri System t 90 minutes e e as for at l e event of f ir h t in

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

10.3 10.8

115 125

1.03 1.28


40

Outdoor Cables

Fiber Optic Cables

Universal cable with system integrity

Rodent-protected universal cable with central loose tube (2500 N) and system integrity in the event of fire

FiberConnect® U-DQ(ZN)HWH n…

Outer jacket Corrugated steel conduit

Order no. 84 047    Standardisation DIN VDE 0888, Part 6 Application Mechanically rugged cable with increased tensile strength that can be used both inside and outside buildings. Installation in cable ducts, on cable trays or in cable conduits. Construction Cable core Loose tube, gel-filled Inner fire protection tape Strain relief elements Non-metallic (E-glass yarn), water-absorbent Inner jacket Halogen-free and flame-retardant Corrugated steel conduit As outer fire barrier and rodent protection Outer jacket Halogen-free and flame-retardant material Colour of jacket Blue Thermal Transport and storage –25°C to +70°C properties Installation –5°C to +50°C Mechanical properties

Fire performance

Operation min. bending radius max. pull force max. crush resistance Flame retardancy

–20°C to +60°C static 15 x outside diameter dynamic 20 x outside diameter long-term 2500 N long-term 2500 N/dm IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Smoke density

IEC 61034

Halogen-free

IEC 60754-2

No corrosive and toxic fumes System Acc. to IEC 60 331-11, IEC 60 331-25 and EN 50200 integrity test 120 min (VDE test report)

Max. number of fibers

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

12 24

12.5 12.5

215 215

2.8 2.8

Inner jacket Central loose tube, gel-filled Inner fire protection tape Strain relief

ty integri Systemt 120 minutes e e as for at l e event of f ir h t in

www.leoni-fiber-optics.com


FiberConnect®

FiberTech®

FiberSwitch®

FiberSplit® Outdoor Cables

41

FO Cables

Rodent-protected universal cable with stranded tight buffered fibers

FiberConnect® U-VQ(ZN)BH n…

Outer jacket Ripcord

Order no. 84 950 165  Standardisation DIN VDE 0888, Part 6 Application Cable for use both inside and outside buildings. Installation in cable ducts, on cable trays or in cable conduits. Non-metallic universal cable for direct connector assembly. Suitable for all types of installation in protective conduits. Construction Cable core Glass fiber-reinforced central strength member with strand elements, designed as tight buffered fibers (TB) and if applicable dummy elements Armour Multi-functional, strengthened E-glass yarn, water-absorbent as non-metallic strain relief elements and rodent protection Cable jacket Halogen-free and flame-retardant material Colour of jacket Yellow Thermal Transport and storage –25°C to +70°C properties Installation –5°C to +50°C Mechanical properties

Fire performance

Operation min. bending radius max. pull force

–20°C to +60°C static 15 x outside diameter dynamic 20 x outside diameter long-term 2500 N

max. crush resistance

long-term

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Smoke density

IEC 61034

Halogen-free

IEC 60754-2

1000 N/dm

No corrosive and toxic fumes Number of fibers

4 6 8 10 12 16 20 24

www.leoni-fiber-optics.com

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

9.4 9.4 9.4 9.8 9.8 10.8 10.8 11.1

130 130 130 145 145 150 150 155

1.03 1.03 1.03 1.21 1.21 1.37 1.37 1.44

Tight buffered fiber Water-absorbent fleece GFR central strength member Strain relief elements and rodent protection


42

Outdoor Cables

Fiber Optic Cables

Rodent-protected universal cable with central loose tube (1750 N)

FiberConnect® U-DQ(ZN)BH n… 1750 N Outer jacket

Order no.

Strain relief elements and rodent

84 025   

protection

Standardisation DIN VDE 0888, Part 6

Loose tube, gel-filled

Application

Non-metallic, light and flexible cable that can be used both inside and outside buildings. Installation in cable ducts, on cable trays or in cable conduits.

Construction

Cable core

Loose tube, gel-filled

Armour

Multi-functional E-glass yarn, water-absorbent as non-metallic strain relief elements and rodent protection

Cable jacket

Halogen-free and flame-retardant material

Colour of jacket

Yellow

Transport and storage

–25°C to +70°C

Installation

–5°C to +50°C

Operation

–20°C to +60°C

min. bending radius

static dynamic

15 x outside diameter 20 x outside diameter

max. pull force

long-term

1750 N

max. crush resistance

long-term

1500 N/dm

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-24 Cat. C

Smoke density

IEC 61034

Halogen-free

IEC 60754-2

Thermal properties Mechanical properties

Fire performance

No corrosive and toxic fumes

Max. number of fibers

12 24

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

7.0 7.5

55 60

0.71 0.79

www.leoni-fiber-optics.com


FiberConnect®

FiberTech®

FiberSwitch®

FiberSplit® Outdoor Cables

43

FO Cables

Rodent-protected universal cable with central loose tube (2500 N)

FiberConnect® U-DQ(ZN)BH n… 2500 N Outer jacket

Order no.

Ripcord

84 032   

Strain relief elements and rodent

Standardisation DIN VDE 0888, Part 6 Application

Non-metallic, light and flexible cable with increased tensile strength that can be used both inside and outside buildings. Installation in cable ducts, on cable trays or in cable conduits.

Construction

Cable core

Loose tube, gel-filled

Armour

Multi-functional, strengthened E-glass yarn, water-absorbent as non-metallic strain relief elements and rodent protection

Cable jacket

Halogen-free and flame-retardant material

Colour of jacket

Yellow

Transport and storage

–25°C to +70°C

Installation

–5°C to +50°C

Operation

–20°C to +60°C

min. bending radius

static dynamic

15 x outside diameter 20 x outside diameter

max. pull force

long-term

2500 N

max. crush resistance

long-term

3000 N/dm

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Smoke density

IEC 61034

Halogen-free

IEC 60754-2

Thermal properties Mechanical properties

Fire performance

No corrosive and toxic fumes

Max. number of fibers

12 24

www.leoni-fiber-optics.com

Outer Ø

Weight

mm

kg/km

Fire load MJ/m

9.2 9.7

100 110

1.25 1.34

protection Loose tube, gel-filled


44

Outdoor Cables

Fiber Optic Cables

Universal cable with stranded loose tubes

FiberConnect® U-DH nxm… Outer jacket

Order no.

Ripcord

84 029   

GFR central strength member

Standardisation DIN VDE 0888, Part 6 Application

Non-metallic cable, can be used both inside and outside buildings. Installation in cable ducts, on cable trays or in cable conduits.

Construction

Cable core

Glass fiber-reinforced central strength member with strand elements, designed as loose tubes and if applicable dummy elements

Cable jacket

Halogen-free and flame-retardant material

Colour of jacket

Yellow

Transport and storage

–25°C to +70°C

Installation

–5°C to +50°C

Operation

–25°C to +60°C

min. bending radius

static dynamic

15 x outside diameter 20 x outside diameter

max. pull force

long-term

1500 N

max. crush resistance

long-term

2000 N/dm

Flame retardancy

IEC 60332-1-2

Smoke density

IEC 61034

Halogen-free

IEC 60754-2

Thermal properties Mechanical properties

Fire performance

Loose tube, gel-filled

No corrosive and toxic fumes

Number of tubes

1xm 2xm 3xm 4xm 5xm 6xm 7xm 8xm

Max. number of fibers

12 24 36 48 60 72 84 96

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

10.5 10.5 10.5 10.5 10.5 11.0 11.7 12.4

105 105 105 105 105 125 130 145

2.2 2.2 2.2 2.2 2.2 2.6 2.9 3.0

www.leoni-fiber-optics.com


FiberConnect®

FiberTech®

FiberSwitch®

FiberSplit® Outdoor Cables

45

FO Cables

Rodent-protected universal cable with stranded loose tubes

Strain relief elements and rodent

FiberConnect® U-DQ(ZN)BH nxm…

protection Outer jacket

Order no. 84 033    Standardisation DIN VDE 0888, Part 6 Application Non-metallic cable, can be used both inside and outside buildings. Installation in cable ducts, on cable trays or in cable conduits. Construction Cable core Glass fiber-reinforced support elements with strand elements, designed as loose tubes and if applicable dummy elements Armour Multi-functional, strengthened E-glass yarn, water-absorbent as non-metallic strain relief elements and rodent protection Cable jacket Halogen-free and flame-retardant material Colour of jacket Yellow Thermal Transport and storage –25°C to +70°C properties Installation –5°C to +50°C Mechanical properties

Fire performance

Operation min. bending radius max. pull force max. crush resistance Flame retardancy

–25°C to +60°C static 15 x outside diameter dynamic 20 x outside diameter long-term 6000 N long-term 3000 N/dm IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Smoke density

IEC 61034

Halogen-free

IEC 60754-2

No corrosive and toxic fumes

Number of tubes

Max. number of fibers

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

12 24 36 48 60 72 96 120 144

12.5 12.5 12.5 12.5 12.5 13.4 14.4 15.9 17.7

185 185 185 185 185 200 225 250 305

3.1 3.1 3.1 3.1 3.1 3.2 3.4 3.7 4.5

1xm 2xm 3xm 4xm 5xm 6xm 8xm 10 x m 12 x m

www.leoni-fiber-optics.com

Ripcord GFR central support member Loose tube, gel-filled


46

Outdoor Cables

Fiber Optic Cables

Transversely waterproof universal cable with central loose tube

Aluminium tape

FiberConnect® U-DQ(ZN)(L)H n…

Strain relief elements and rodent protection

Order no.

84 034   

Outer jacket

Application

Can be used both inside and outside buildings. Installation in cable ducts, on cable trays, in cable conduits or directly in the ground.

Ripcord

Construction

Thermal properties Mechanical properties

Fire performance

Cable core

Loose tube, gel-filled

Strain relief elements

Non-metallic (E-glass yarn), water-absorbent

Aluminium tape

For transversal water resistance

Cable jacket

Halogen-free and flame-retardant material

Colour of jacket

Yellow

Transport and storage

–25°C to +70°C

Installation

–5°C to +50°C

Operation

–20°C to +60°C

min. bending radius

static dynamic

15 x outside diameter 20 x outside diameter

max. pull force

long-term

2500 N

max. crush resistance

long-term

1000 N/dm

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Smoke density

IEC 61034

Halogen-free

IEC 60754-2

Loose tube, gel-filled

No corrosive and toxic fumes

Max. number of fibers

12 24

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

10.8 11.3

160 165

1.50 1.57

www.leoni-fiber-optics.com


FiberConnect®

FiberTech®

FiberSwitch®

FiberSplit® Outdoor Cables

47

FO Cables

Rodent-protected, transversely waterproof universal cable with central loose tube

FiberConnect® U-DQ(ZN)HWH n…

Strain relief elements Outer jacket

Order no.

84 030   

Corrugated steel conduit

Application

Can be used both inside and outside buildings. Installation in cable ducts, on cable trays, in cable conduits or directly in the ground.

Loose tube, gel-filled

Construction

Cable core

Loose tube, gel-filled

Strain relief elements

Non-metallic (E-glass yarn), water-absorbent

Inner jacket

Halogen-free and flame-retardant

Corrugated steel conduit As highly effective rodent protection

Thermal properties Mechanical properties

Fire performance

Outer jacket

Halogen-free and flame-retardant material

Colour of jacket

Yellow

Transport and storage

–25°C to +70°C

Installation

–5°C to +50°C

Operation

–20°C to +60°C

min. bending radius

static dynamic

15 x outside diameter 20 x outside diameter

max. pull force

long-term

2500 N

max. crush resistance

long-term

2500 N/dm

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Smoke density

IEC 61034

Halogen-free

IEC 60754-2

No corrosive and toxic fumes

Max. number of fibers

12 24

www.leoni-fiber-optics.com

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

12.5 12.5

215 215

2.80 2.80


48

Outdoor Cables

Fiber Optic Cables

Transversely waterproof universal cable with stranded loose tubes

FiberConnect® U-DQ(ZN)(L)H nxm…

Strain relief elements Outer jacket

Order no.

84 035   

Aluminium tape

Application

Can be used both inside and outside buildings. Installation in cable ducts, on cable trays, in cable conduits or directly in the ground.

GFR central strength member

Construction

Thermal properties Mechanical properties

Fire performance

Cable core

Glass fiber-reinforced central strength member with strand elements, designed as gel-filled loose tubes and if applicable dummy elements

Strain relief elements

Non-metallic (E-glass yarn), water-absorbent

Aluminium tape

For transversal water resistance

Cable jacket

Halogen-free and flame-retardant material

Colour of jacket

Yellow

Transport and storage

–25°C to +70°C

Installation

–5°C to +50°C

Operation

–20°C to +60°C

min. bending radius

static dynamic

15 x outside diameter 20 x outside diameter

max. pull force

long-term

3000 N

max. crush resistance

long-term

1500 N/dm

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Smoke density

IEC 61034

Halogen-free

IEC 60754-2

Loose tube, gel-filled

No corrosive and toxic fumes

Number of tubes

1xm 2xm 3xm 4xm 5xm 6xm 8xm 10 x m 12 x m

Max. number of fibers

12 24 36 48 60 72 96 120 144

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

12.1 12.1 12.1 12.1 12.1 13.0 14.4 15.9 17.7

170 170 170 170 170 190 230 270 320

2.73 2.73 2.73 2.73 2.73 3.13 3.28 3.60 4.39

www.leoni-fiber-optics.com


FiberConnect®

FiberTech®

FiberSwitch®

FiberSplit® Outdoor Cables

49

FO Cables

Rodent-protected, transversely waterproof universal cable with stranded loose tubes

FiberConnect® U-DQ(ZN)WH nxm…

Strain relief elements Outer jacket

Order no.

84 037   

Corrugated steel conduit

Application

Can be used both inside and outside buildings. Installation in cable ducts, on cable trays, in cable conduits or directly in the ground.

GFR central strength member

Construction

Cable core

Glass fiber-reinforced central strength member with strand elements, designed as gel-filled loose tubes and if applicable dummy elements

Strain relief elements

Non-metallic (E-glass yarn), water-absorbent

Corrugated steel conduit As highly effective rodent protection

Thermal properties Mechanical properties

Fire performance

Cable jacket

Halogen-free and flame-retardant material

Colour of jacket

Yellow

Transport and storage

–25°C to +70°C

Installation

–5°C to +50°C

Operation

–20°C to +60°C

min. bending radius

static dynamic

15 x outside diameter 20 x outside diameter

max. pull force

long-term

3000 N

max. crush resistance

long-term

2000 N/dm

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Smoke density

IEC 61034

Halogen-free

IEC 60754-2

No corrosive and toxic fumes

Number of tubes

Max. number of fibers

1xm 2xm 3xm 4xm 5xm 6xm 8xm 10 x m

www.leoni-fiber-optics.com

12 24 36 48 60 72 96 120

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

12.7 12.7 12.7 12.7 12.7 16.5 16.5 16.5

200 200 200 200 200 305 305 305

3.45 3.45 3.45 3.45 3.45 4.05 4.05 4.05

Loose tube, gel-filled


50

Outdoor Cables

Fiber Optic Cables

Rodent-protected outdoor cable with central loose tube (1750 N)

FiberConnect® A-DQ(ZN)B2Y n… 1750 N Order no.

Outer jacket

84 305   

Loose tube, gel-filled

Standardisation IEC 60 794-3 Application

Light, flexible and non-metallic outdoor cable for primary cabling and the backbone area. For pulling into conduits, installation on cable trays or directly in the ground.

Construction

Cable core

Loose tube, gel-filled

Armour

Multi-functional E-glass yarn, water-absorbent as strain relief and rodent protection

Cable jacket

PE jacket with imprint

Colour of jacket

Black

Transport and storage

–25°C to +70°C

Installation

–5°C to +50°C

Operation

–20°C to +60°C

min. bending radius

static dynamic

15 x outside diameter 20 x outside diameter

max. pull force

long-term

1750 N

max. crush resistance

long-term

1500 N/dm

Thermal properties Mechanical properties

Fire performance

Jacket is halogen-free

Note

The jacket material PE offers good protection against transversal water ingress.

Max. number of fibers

12 24

Strain relief elements and rodent protection

No corrosive and toxic fumes

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

7.0 7.5

42 47

1.11 1.20

www.leoni-fiber-optics.com


FiberConnect®

FiberTech®

FiberSwitch®

FiberSplit® Outdoor Cables

51

FO Cables

Rodent-protected outdoor cable with central loose tube (2500 N)

FiberConnect® A-DQ(ZN)B2Y n… 2500 N Outer jacket

Order no.

Ripcord

84 321   

Loose tube, gel-filled

Standardisation IEC 60 794-3 Application

Non-metallic construction for primary cabling and the backbone area. For pulling into conduits, installation on cable trays or directly in the ground.

Construction

Cable core

Loose tube, gel-filled

Armour

Multi-functional, strengthened E-glass yarn, water-absorbent as strain relief and rodent protection

Cable jacket

PE jacket with imprint

Colour of jacket

Black

Transport and storage

–25°C to +70°C

Installation

–5°C to +50°C

Operation

–20°C to +60°C

min. bending radius

static dynamic

15 x outside diameter 20 x outside diameter

max. pull force

long-term

2500 N

max. crush resistance

long-term

3000 N/dm

Thermal properties Mechanical properties

Fire performance

Jacket is halogen-free

Note

The jacket material PE offers good protection against transversal water ingress.

No corrosive and toxic fumes

Max. number of fibers

12 24

www.leoni-fiber-optics.com

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

9.2 9.7

76 81

1.90 2.00

Strain relief elements and rodent protection


52

Outdoor Cables

Fiber Optic Cables

Rodent-protected, dry-core outdoor cable with stranded loose tubes

FiberConnect® A-DQ(ZN)B2Y nxm…

Outer jacket Water-absorbent fleece

Order no. 84 316    Standardisation DIN VDE 0888, Part 3 and IEC 60 794-3 Application Non-metallic, rugged outdoor cable. Installation-friendly because of the cable core kept free of grease. Installation in conduits, on cable trays or directly in the ground. Construction Cable core Glass fiber-reinforced central strength member with strand elements, designed as gel-filled loose tubes and if applicable dummy elements Water-absorbent fleece Armour Multi-functional, strengthened E-glass yarn as non-metallic strain relief elements and rodent protection Cable jacket PE jacket with hot-stamped marking Colour of jacket Black Thermal Transport and storage –40°C to +70°C properties Installation –5°C to +50°C Mechanical properties

Fire performance Note

Operation min. bending radius max. pull force max. crush resistance Jacket is halogen-free

Ripcord Loose tube, gel-filled Strain relief elements and rodent protection GFR central strength member

–40°C to +60°C static 15 x outside diameter dynamic 20 x outside diameter long-term 4000 N long-term 3000 N/dm

No corrosive and toxic fumes The jacket material PE offers good protection against transversal water ingress. Higher fiber numbers and pull forces on request. Also available with aluminium or corrugated steel tape.

Number of tubes

1xm 2xm 3xm 4xm 5xm 6xm 8xm 10 x m 12 x m

Max. number of fibers

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

12 24 36 48 60 72 96 120 144

11.4 11.4 11.4 11.4 11.4 12.3 13.7 15.2 17.0

115 115 115 115 115 135 160 190 230

4.1 4.1 4.1 4.1 4.1 4.5 5.0 5.5 6.2 www.leoni-fiber-optics.com


FiberConnect®

FiberTech®

FiberSwitch®

FiberSplit® Outdoor Cables

53

FO Cables

Grease-filled outdoor cable with stranded loose tubes

FiberConnect® A-DF(ZN)2Y nxm…

Outer jacket Water-absorbent fleece

Order no. 84 300    Standardisation DIN VDE 0888, Part 3 and IEC 60 794-3 Application Non-metallic, rugged outdoor cable for primary cabling and the backbone area. Installation in conduits, on cable trays or directly in the ground. Construction Cable core Glass fiber-reinforced central strength member with strand elements, designed as gel-filled loose tubes and if applicable dummy elements. Cable core filled with water-blocking gel. Strain relief element E-glass yarn Cable jacket PE jacket with hot-stamped marking Colour of jacket Black Thermal Transport and storage –40°C to +70°C properties Installation –5°C to +50°C Mechanical properties

Operation min. bending radius max. pull force

Fire performance Note

No corrosive and toxic fumes The jacket material PE offers good protection against transversal water ingress. Also available with aluminium or corrugated steel tape and copper elements.

Number of tubes

max. crush resistance Jacket is halogen-free

–40°C to +60°C static 15 x outside diameter dynamic 20 x outside diameter long-term ≤ 7 strand elements 3000 N > 7 strand elements 4000 N long-term 3000 N/dm

Max. number of fibers

1xm 2xm 3xm 4xm 5xm 6xm 8xm 10 x m 12 x m 16 x m

www.leoni-fiber-optics.com

12 24 36 48 60 72 96 120 144 192

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

11.4 11.4 11.4 11.4 11.4 12.3 13.7 15.2 17.0 16.8

120 120 120 120 120 135 170 200 240 255

4.3 4.3 4.3 4.3 4.3 4.6 5.1 5.7 6.5 7.4

Loose tube, gel-filled Core filling Strain relief elements GFR central strength member


54

Outdoor Cables

Fiber Optic Cables

Rodent-secure, grease-filled outdoor cable with stranded loose tubes

FiberConnect® A-DF(ZN)2YW2Y nxm…

Outer jacket Corrugated steel conduit

Order no. 84 310    Standardisation DIN VDE 0888, Part 3 and IEC 60 794-3 Application Rugged outdoor cable for primary cabling and the backbone area. Installation in conduits, on cable trays or directly in the ground. Construction Cable core Glass fiber-reinforced central strength member with strand elements, designed as gel-filled loose tubes and if applicable dummy elements. Cable core filled with water-blocking gel. Strain relief element E-glass yarn Inner jacket (black) PE jacket Corrugated steel conduit As highly effective rodent protection Cable jacket PE jacket with hot-stamped marking Colour of jacket Black Thermal Transport and storage –40°C to +70°C properties Installation –5°C to +50°C Mechanical properties

Operation min. bending radius max. pull force

Fire performance

Number of tubes

1xm 2xm 3xm 4xm 5xm 6xm 8xm 10 x m 12 x m 16 x m

max. crush resistance Jacket is halogen-free

Inner jacket Water-absorbent fleece Loose tube, gel-filled Strain relief elements GFR central strength member

–40°C to +60°C static 15 x outside diameter dynamic 20 x outside diameter long-term ≤ 7 strand elements 3000 N > 7 strand elements 4000 N long-term 3000 N/dm

No corrosive and toxic fumes

Max. number of fibers

12 24 36 48 60 72 96 120 144 192

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

16.7 16.7 16.7 16.7 16.7 18.8 18.8 21.8 21.8 21.8

275 275 275 275 275 335 335 335 370 380

10.4 10.4 10.4 10.4 10.4 12.0 12.0 12.5 13.1 13.8

www.leoni-fiber-optics.com


FiberConnect®

FiberTech®

FiberSwitch®

FiberSplit® Outdoor Cables

55

FO Cables

Transversely waterproof outdoor cable with central loose tube

FiberConnect® A-DQ(ZN)(L)2Y n…

Outer jacket Aluminium tape

Order no.

Ripcord

84 333   

Loose tube, gel-filled

Standardisation DIN VDE 0888, Part 3 and IEC 60 794-3 Application

Light outdoor cable with diffusion barrier. Installation in cable ducts, on cable trays, in cable conduits or directly in the ground.

Construction

Cable core

Loose tube, gel-filled

Strain relief element

Non-metallic (E-glass yarn), water-absorbent

Aluminium tape

For transversal water resistance

Cable jacket

PE jacket with imprint

Colour of jacket

Black

Transport and storage

–25°C to +70°C

Installation

–5°C to +50°C

Thermal properties Mechanical properties

Fire performance

Operation

–20°C to +60°C

min. bending radius

static dynamic

15 x outside diameter 20 x outside diameter

max. pull force

long-term

2500 N

max. crush resistance

long-term

1000 N/dm

Jacket is halogen-free No corrosive and toxic fumes

Max. number of fibers

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

12 24

10.8 11.3

128 135

1.42 1.62

www.leoni-fiber-optics.com

Strain relief elements


56

Outdoor Cables

Fiber Optic Cables

Rodent-protected, transversely waterproof outdoor cable with central loose tube

FiberConnect® A-DQ(ZN)2YW2Y n…

Outer jacket Corrugated steel conduit

Order no.

Inner jacket

84 331   

Loose tube, gel-filled

Standardisation DIN VDE 0888, Part 3 and IEC 60 794-3 Application

Rugged outdoor cable for installation in cable ducts, on cable trays, in conduits or directly in the ground

Construction

Cable core

Loose tube, gel-filled

Strain relief element

Non-metallic (E-glass yarn), water-absorbent

Inner jacket (black)

PE jacket

Strain relief elements

Corrugated steel conduit As highly effective rodent protection

Thermal properties Mechanical properties

Fire performance

Number of fibers

12 24

Outer jacket

PE jacket with imprint

Colour of jacket

Black

Transport and storage

–40°C to +70°C

Installation

–5°C to +50°C

Operation

–40°C to +60°C

min. bending radius

static dynamic

15 x outside diameter 20 x outside diameter

max. pull force

long-term

2500 N

max. crush resistance

long-term

2500 N/dm

Jacket is halogen-free No corrosive and toxic fumes

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

12.5 12.5

160 160

1.8 1.8

www.leoni-fiber-optics.com


FiberConnect®

FiberTech®

FiberSwitch®

FiberSplit® Outdoor Cables

57

FO Cables

Transversely waterproof outdoor cable with stranded loose tubes

FiberConnect® A-DQ(ZN)(L)2Y nxm…

Outer jacket Aluminium tape

Order no.

Ripcord

84 326   

Water-absorbent fleece

Standardisation DIN VDE 0888, Part 3 and IEC 60 794-3 Application

Rugged outdoor cable with diffusion barrier. Installation in cable ducts, on cable trays, in cable conduits or directly in the ground.

Construction

Cable core

Glass fiber-reinforced central strength member with strand elements, designed as gel-filled loose tubes and if applicable dummy elements

Strain relief element

Non-metallic (E-glass yarn), water-absorbent

Aluminium tape

For transversal water resistance

Cable jacket

PE jacket with hot-stamped marking

Colour of jacket

Black

Transport and storage

–40°C to +70°C

Installation

–5°C to +50°C

Operation

–40°C to +60°C

min. bending radius

static dynamic

15 x outside diameter 20 x outside diameter

max. pull force

long-term

3000 N

max. crush resistance

long-term

1500 N/dm

Thermal properties Mechanical properties

Fire performance

Number of tubes

Jacket is halogen-free No corrosive and toxic fumes

Max. number of fibers

1xm 2xm 3xm 4xm 5xm 6xm 8xm 10 x m 12 x m

www.leoni-fiber-optics.com

12 24 36 48 60 72 96 120 144

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

12.1 12.1 12.1 12.1 12.1 13.0 14.4 15.9 17.7

140 140 140 140 140 160 200 240 280

4.9 4.9 4.9 4.9 4.9 5.6 5.9 6.4 7.2

Loose tube, gel-filled Strain relief elements GFR central strength member


58

Outdoor Cables

Fiber Optic Cables

Rodent-protected, transversely waterproof outdoor cable with stranded loose tubes

FiberConnect® A-DQ(ZN)W2Y nxm...

Outer jacket Corrugated steel conduit

Order no.

Ripcord

84 334   

Loose tube, gel-filled

Standardisation DIN VDE 0888, Part 3 and IEC 60 794-3 Application

Rugged outdoor cable for installation in cable ducts, on cable trays, in conduits or directly in the ground

Construction

Cable core

Glass fiber-reinforced central strength member with strand elements, designed as gel-filled loose tubes and if applicable dummy elements

Strain relief element

Non-metallic (E-glass yarn), water-absorbent

Strain relief elements GFR central strength member

Corrugated steel conduit As highly effective rodent protection

Thermal properties Mechanical properties

Fire performance

Cable jacket

PE jacket with hot-stamped marking

Colour of jacket

Black

Transport and storage

–40°C to +70°C

Installation

–5°C to +50°C

Operation

–40°C to +60°C

min. bending radius

static dynamic

15 x outside diameter 20 x outside diameter

max. pull force

long-term

3000 N

max. crush resistance

long-term

2000 N/dm

Jacket is halogen-free No corrosive and toxic fumes

Number of tubes

Max. number of fibers

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

1xm 2xm 3xm 4xm 5xm

12 24 26 48 60

12.7 12.7 12.7 12.7 12.7

165 165 165 165 165

4.6 4.6 4.6 4.6 4.6

www.leoni-fiber-optics.com