FiberConnect®
FiberTech®
FiberSwitch®
FiberSplit® Outdoor Cables
39
FO Cables
Universal cable with system integrity
Rodent-protected universal cable with central loose tube (2500 N) and system integrity in the event of fire
FiberConnect® U-D(ZN)BH n…2500 N
Outer jacket Central loose tube, gel-filled Ripcord
84 040
Order no.
Inner fire protection tape
Standardisation DIN VDE 0888, Part 6 Application
Non-metallic, light and flexible cable with increased tensile strength that can be used both inside and outside buildings. Installation in cable ducts, on cable trays or in cable conduits.
Construction
Cable core
Strain relief and rodent protection
Loose tube, gel-filled
Inner fire protection tape
Thermal properties Mechanical properties
Fire performance
Armour
Multi-functional, strengthened E-glass yarn, water-absorbent as non-metallic strain relief elements and rodent protection
Cable jacket
Halogen-free and flame-retardant material
Colour of jacket
Blue
Transport and storage
–25°C to +70°C
Installation
–5°C to +50°C
Operation
–20°C to +60°C
min. bending radius
static dynamic
15 x outside diameter 20 x outside diameter
max. pull force
long-term
2500 N
max. crush resistance
long-term
3000 N/dm
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
Smoke density
IEC 61034
Halogen-free
IEC 60754-2
No corrosive and toxic fumes System Acc. to IEC 60 331-11, IEC 60 331-25 and EN 50200 integrity test 90 min (VDE test report)
Max. number of fibers
12 24
www.leoni-fiber-optics.com
ty integri System t 90 minutes e e as for at l e event of f ir h t in
Outer Ø
Weight
Fire load
mm
kg/km
MJ/m
10.3 10.8
115 125
1.03 1.28
40
Outdoor Cables
Fiber Optic Cables
Universal cable with system integrity
Rodent-protected universal cable with central loose tube (2500 N) and system integrity in the event of fire
FiberConnect® U-DQ(ZN)HWH n…
Outer jacket Corrugated steel conduit
Order no. 84 047 Standardisation DIN VDE 0888, Part 6 Application Mechanically rugged cable with increased tensile strength that can be used both inside and outside buildings. Installation in cable ducts, on cable trays or in cable conduits. Construction Cable core Loose tube, gel-filled Inner fire protection tape Strain relief elements Non-metallic (E-glass yarn), water-absorbent Inner jacket Halogen-free and flame-retardant Corrugated steel conduit As outer fire barrier and rodent protection Outer jacket Halogen-free and flame-retardant material Colour of jacket Blue Thermal Transport and storage –25°C to +70°C properties Installation –5°C to +50°C Mechanical properties
Fire performance
Operation min. bending radius max. pull force max. crush resistance Flame retardancy
–20°C to +60°C static 15 x outside diameter dynamic 20 x outside diameter long-term 2500 N long-term 2500 N/dm IEC 60332-1-2 and IEC 60332-3-22 Cat. A
Smoke density
IEC 61034
Halogen-free
IEC 60754-2
No corrosive and toxic fumes System Acc. to IEC 60 331-11, IEC 60 331-25 and EN 50200 integrity test 120 min (VDE test report)
Max. number of fibers
Outer Ø
Weight
Fire load
mm
kg/km
MJ/m
12 24
12.5 12.5
215 215
2.8 2.8
Inner jacket Central loose tube, gel-filled Inner fire protection tape Strain relief
ty integri Systemt 120 minutes e e as for at l e event of f ir h t in
www.leoni-fiber-optics.com
FiberConnect®
FiberTech®
FiberSwitch®
FiberSplit® Outdoor Cables
41
FO Cables
Rodent-protected universal cable with stranded tight buffered fibers
FiberConnect® U-VQ(ZN)BH n…
Outer jacket Ripcord
Order no. 84 950 165 Standardisation DIN VDE 0888, Part 6 Application Cable for use both inside and outside buildings. Installation in cable ducts, on cable trays or in cable conduits. Non-metallic universal cable for direct connector assembly. Suitable for all types of installation in protective conduits. Construction Cable core Glass fiber-reinforced central strength member with strand elements, designed as tight buffered fibers (TB) and if applicable dummy elements Armour Multi-functional, strengthened E-glass yarn, water-absorbent as non-metallic strain relief elements and rodent protection Cable jacket Halogen-free and flame-retardant material Colour of jacket Yellow Thermal Transport and storage –25°C to +70°C properties Installation –5°C to +50°C Mechanical properties
Fire performance
Operation min. bending radius max. pull force
–20°C to +60°C static 15 x outside diameter dynamic 20 x outside diameter long-term 2500 N
max. crush resistance
long-term
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
Smoke density
IEC 61034
Halogen-free
IEC 60754-2
1000 N/dm
No corrosive and toxic fumes Number of fibers
4 6 8 10 12 16 20 24
www.leoni-fiber-optics.com
Outer Ø
Weight
Fire load
mm
kg/km
MJ/m
9.4 9.4 9.4 9.8 9.8 10.8 10.8 11.1
130 130 130 145 145 150 150 155
1.03 1.03 1.03 1.21 1.21 1.37 1.37 1.44
Tight buffered fiber Water-absorbent fleece GFR central strength member Strain relief elements and rodent protection
42
Outdoor Cables
Fiber Optic Cables
Rodent-protected universal cable with central loose tube (1750 N)
FiberConnect® U-DQ(ZN)BH n… 1750 N Outer jacket
Order no.
Strain relief elements and rodent
84 025
protection
Standardisation DIN VDE 0888, Part 6
Loose tube, gel-filled
Application
Non-metallic, light and flexible cable that can be used both inside and outside buildings. Installation in cable ducts, on cable trays or in cable conduits.
Construction
Cable core
Loose tube, gel-filled
Armour
Multi-functional E-glass yarn, water-absorbent as non-metallic strain relief elements and rodent protection
Cable jacket
Halogen-free and flame-retardant material
Colour of jacket
Yellow
Transport and storage
–25°C to +70°C
Installation
–5°C to +50°C
Operation
–20°C to +60°C
min. bending radius
static dynamic
15 x outside diameter 20 x outside diameter
max. pull force
long-term
1750 N
max. crush resistance
long-term
1500 N/dm
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-24 Cat. C
Smoke density
IEC 61034
Halogen-free
IEC 60754-2
Thermal properties Mechanical properties
Fire performance
No corrosive and toxic fumes
Max. number of fibers
12 24
Outer Ø
Weight
Fire load
mm
kg/km
MJ/m
7.0 7.5
55 60
0.71 0.79
www.leoni-fiber-optics.com
FiberConnect®
FiberTech®
FiberSwitch®
FiberSplit® Outdoor Cables
43
FO Cables
Rodent-protected universal cable with central loose tube (2500 N)
FiberConnect® U-DQ(ZN)BH n… 2500 N Outer jacket
Order no.
Ripcord
84 032
Strain relief elements and rodent
Standardisation DIN VDE 0888, Part 6 Application
Non-metallic, light and flexible cable with increased tensile strength that can be used both inside and outside buildings. Installation in cable ducts, on cable trays or in cable conduits.
Construction
Cable core
Loose tube, gel-filled
Armour
Multi-functional, strengthened E-glass yarn, water-absorbent as non-metallic strain relief elements and rodent protection
Cable jacket
Halogen-free and flame-retardant material
Colour of jacket
Yellow
Transport and storage
–25°C to +70°C
Installation
–5°C to +50°C
Operation
–20°C to +60°C
min. bending radius
static dynamic
15 x outside diameter 20 x outside diameter
max. pull force
long-term
2500 N
max. crush resistance
long-term
3000 N/dm
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
Smoke density
IEC 61034
Halogen-free
IEC 60754-2
Thermal properties Mechanical properties
Fire performance
No corrosive and toxic fumes
Max. number of fibers
12 24
www.leoni-fiber-optics.com
Outer Ø
Weight
mm
kg/km
Fire load MJ/m
9.2 9.7
100 110
1.25 1.34
protection Loose tube, gel-filled
44
Outdoor Cables
Fiber Optic Cables
Universal cable with stranded loose tubes
FiberConnect® U-DH nxm… Outer jacket
Order no.
Ripcord
84 029
GFR central strength member
Standardisation DIN VDE 0888, Part 6 Application
Non-metallic cable, can be used both inside and outside buildings. Installation in cable ducts, on cable trays or in cable conduits.
Construction
Cable core
Glass fiber-reinforced central strength member with strand elements, designed as loose tubes and if applicable dummy elements
Cable jacket
Halogen-free and flame-retardant material
Colour of jacket
Yellow
Transport and storage
–25°C to +70°C
Installation
–5°C to +50°C
Operation
–25°C to +60°C
min. bending radius
static dynamic
15 x outside diameter 20 x outside diameter
max. pull force
long-term
1500 N
max. crush resistance
long-term
2000 N/dm
Flame retardancy
IEC 60332-1-2
Smoke density
IEC 61034
Halogen-free
IEC 60754-2
Thermal properties Mechanical properties
Fire performance
Loose tube, gel-filled
No corrosive and toxic fumes
Number of tubes
1xm 2xm 3xm 4xm 5xm 6xm 7xm 8xm
Max. number of fibers
12 24 36 48 60 72 84 96
Outer Ø
Weight
Fire load
mm
kg/km
MJ/m
10.5 10.5 10.5 10.5 10.5 11.0 11.7 12.4
105 105 105 105 105 125 130 145
2.2 2.2 2.2 2.2 2.2 2.6 2.9 3.0
www.leoni-fiber-optics.com
FiberConnect®
FiberTech®
FiberSwitch®
FiberSplit® Outdoor Cables
45
FO Cables
Rodent-protected universal cable with stranded loose tubes
Strain relief elements and rodent
FiberConnect® U-DQ(ZN)BH nxm…
protection Outer jacket
Order no. 84 033 Standardisation DIN VDE 0888, Part 6 Application Non-metallic cable, can be used both inside and outside buildings. Installation in cable ducts, on cable trays or in cable conduits. Construction Cable core Glass fiber-reinforced support elements with strand elements, designed as loose tubes and if applicable dummy elements Armour Multi-functional, strengthened E-glass yarn, water-absorbent as non-metallic strain relief elements and rodent protection Cable jacket Halogen-free and flame-retardant material Colour of jacket Yellow Thermal Transport and storage –25°C to +70°C properties Installation –5°C to +50°C Mechanical properties
Fire performance
Operation min. bending radius max. pull force max. crush resistance Flame retardancy
–25°C to +60°C static 15 x outside diameter dynamic 20 x outside diameter long-term 6000 N long-term 3000 N/dm IEC 60332-1-2 and IEC 60332-3-22 Cat. A
Smoke density
IEC 61034
Halogen-free
IEC 60754-2
No corrosive and toxic fumes
Number of tubes
Max. number of fibers
Outer Ø
Weight
Fire load
mm
kg/km
MJ/m
12 24 36 48 60 72 96 120 144
12.5 12.5 12.5 12.5 12.5 13.4 14.4 15.9 17.7
185 185 185 185 185 200 225 250 305
3.1 3.1 3.1 3.1 3.1 3.2 3.4 3.7 4.5
1xm 2xm 3xm 4xm 5xm 6xm 8xm 10 x m 12 x m
www.leoni-fiber-optics.com
Ripcord GFR central support member Loose tube, gel-filled
46
Outdoor Cables
Fiber Optic Cables
Transversely waterproof universal cable with central loose tube
Aluminium tape
FiberConnect® U-DQ(ZN)(L)H n…
Strain relief elements and rodent protection
Order no.
84 034
Outer jacket
Application
Can be used both inside and outside buildings. Installation in cable ducts, on cable trays, in cable conduits or directly in the ground.
Ripcord
Construction
Thermal properties Mechanical properties
Fire performance
Cable core
Loose tube, gel-filled
Strain relief elements
Non-metallic (E-glass yarn), water-absorbent
Aluminium tape
For transversal water resistance
Cable jacket
Halogen-free and flame-retardant material
Colour of jacket
Yellow
Transport and storage
–25°C to +70°C
Installation
–5°C to +50°C
Operation
–20°C to +60°C
min. bending radius
static dynamic
15 x outside diameter 20 x outside diameter
max. pull force
long-term
2500 N
max. crush resistance
long-term
1000 N/dm
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
Smoke density
IEC 61034
Halogen-free
IEC 60754-2
Loose tube, gel-filled
No corrosive and toxic fumes
Max. number of fibers
12 24
Outer Ø
Weight
Fire load
mm
kg/km
MJ/m
10.8 11.3
160 165
1.50 1.57
www.leoni-fiber-optics.com
FiberConnect®
FiberTech®
FiberSwitch®
FiberSplit® Outdoor Cables
47
FO Cables
Rodent-protected, transversely waterproof universal cable with central loose tube
FiberConnect® U-DQ(ZN)HWH n…
Strain relief elements Outer jacket
Order no.
84 030
Corrugated steel conduit
Application
Can be used both inside and outside buildings. Installation in cable ducts, on cable trays, in cable conduits or directly in the ground.
Loose tube, gel-filled
Construction
Cable core
Loose tube, gel-filled
Strain relief elements
Non-metallic (E-glass yarn), water-absorbent
Inner jacket
Halogen-free and flame-retardant
Corrugated steel conduit As highly effective rodent protection
Thermal properties Mechanical properties
Fire performance
Outer jacket
Halogen-free and flame-retardant material
Colour of jacket
Yellow
Transport and storage
–25°C to +70°C
Installation
–5°C to +50°C
Operation
–20°C to +60°C
min. bending radius
static dynamic
15 x outside diameter 20 x outside diameter
max. pull force
long-term
2500 N
max. crush resistance
long-term
2500 N/dm
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
Smoke density
IEC 61034
Halogen-free
IEC 60754-2
No corrosive and toxic fumes
Max. number of fibers
12 24
www.leoni-fiber-optics.com
Outer Ø
Weight
Fire load
mm
kg/km
MJ/m
12.5 12.5
215 215
2.80 2.80
48
Outdoor Cables
Fiber Optic Cables
Transversely waterproof universal cable with stranded loose tubes
FiberConnect® U-DQ(ZN)(L)H nxm…
Strain relief elements Outer jacket
Order no.
84 035
Aluminium tape
Application
Can be used both inside and outside buildings. Installation in cable ducts, on cable trays, in cable conduits or directly in the ground.
GFR central strength member
Construction
Thermal properties Mechanical properties
Fire performance
Cable core
Glass fiber-reinforced central strength member with strand elements, designed as gel-filled loose tubes and if applicable dummy elements
Strain relief elements
Non-metallic (E-glass yarn), water-absorbent
Aluminium tape
For transversal water resistance
Cable jacket
Halogen-free and flame-retardant material
Colour of jacket
Yellow
Transport and storage
–25°C to +70°C
Installation
–5°C to +50°C
Operation
–20°C to +60°C
min. bending radius
static dynamic
15 x outside diameter 20 x outside diameter
max. pull force
long-term
3000 N
max. crush resistance
long-term
1500 N/dm
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
Smoke density
IEC 61034
Halogen-free
IEC 60754-2
Loose tube, gel-filled
No corrosive and toxic fumes
Number of tubes
1xm 2xm 3xm 4xm 5xm 6xm 8xm 10 x m 12 x m
Max. number of fibers
12 24 36 48 60 72 96 120 144
Outer Ø
Weight
Fire load
mm
kg/km
MJ/m
12.1 12.1 12.1 12.1 12.1 13.0 14.4 15.9 17.7
170 170 170 170 170 190 230 270 320
2.73 2.73 2.73 2.73 2.73 3.13 3.28 3.60 4.39
www.leoni-fiber-optics.com
FiberConnect®
FiberTech®
FiberSwitch®
FiberSplit® Outdoor Cables
49
FO Cables
Rodent-protected, transversely waterproof universal cable with stranded loose tubes
FiberConnect® U-DQ(ZN)WH nxm…
Strain relief elements Outer jacket
Order no.
84 037
Corrugated steel conduit
Application
Can be used both inside and outside buildings. Installation in cable ducts, on cable trays, in cable conduits or directly in the ground.
GFR central strength member
Construction
Cable core
Glass fiber-reinforced central strength member with strand elements, designed as gel-filled loose tubes and if applicable dummy elements
Strain relief elements
Non-metallic (E-glass yarn), water-absorbent
Corrugated steel conduit As highly effective rodent protection
Thermal properties Mechanical properties
Fire performance
Cable jacket
Halogen-free and flame-retardant material
Colour of jacket
Yellow
Transport and storage
–25°C to +70°C
Installation
–5°C to +50°C
Operation
–20°C to +60°C
min. bending radius
static dynamic
15 x outside diameter 20 x outside diameter
max. pull force
long-term
3000 N
max. crush resistance
long-term
2000 N/dm
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
Smoke density
IEC 61034
Halogen-free
IEC 60754-2
No corrosive and toxic fumes
Number of tubes
Max. number of fibers
1xm 2xm 3xm 4xm 5xm 6xm 8xm 10 x m
www.leoni-fiber-optics.com
12 24 36 48 60 72 96 120
Outer Ø
Weight
Fire load
mm
kg/km
MJ/m
12.7 12.7 12.7 12.7 12.7 16.5 16.5 16.5
200 200 200 200 200 305 305 305
3.45 3.45 3.45 3.45 3.45 4.05 4.05 4.05
Loose tube, gel-filled
50
Outdoor Cables
Fiber Optic Cables
Rodent-protected outdoor cable with central loose tube (1750 N)
FiberConnect® A-DQ(ZN)B2Y n… 1750 N Order no.
Outer jacket
84 305
Loose tube, gel-filled
Standardisation IEC 60 794-3 Application
Light, flexible and non-metallic outdoor cable for primary cabling and the backbone area. For pulling into conduits, installation on cable trays or directly in the ground.
Construction
Cable core
Loose tube, gel-filled
Armour
Multi-functional E-glass yarn, water-absorbent as strain relief and rodent protection
Cable jacket
PE jacket with imprint
Colour of jacket
Black
Transport and storage
–25°C to +70°C
Installation
–5°C to +50°C
Operation
–20°C to +60°C
min. bending radius
static dynamic
15 x outside diameter 20 x outside diameter
max. pull force
long-term
1750 N
max. crush resistance
long-term
1500 N/dm
Thermal properties Mechanical properties
Fire performance
Jacket is halogen-free
Note
The jacket material PE offers good protection against transversal water ingress.
Max. number of fibers
12 24
Strain relief elements and rodent protection
No corrosive and toxic fumes
Outer Ø
Weight
Fire load
mm
kg/km
MJ/m
7.0 7.5
42 47
1.11 1.20
www.leoni-fiber-optics.com
FiberConnect®
FiberTech®
FiberSwitch®
FiberSplit® Outdoor Cables
51
FO Cables
Rodent-protected outdoor cable with central loose tube (2500 N)
FiberConnect® A-DQ(ZN)B2Y n… 2500 N Outer jacket
Order no.
Ripcord
84 321
Loose tube, gel-filled
Standardisation IEC 60 794-3 Application
Non-metallic construction for primary cabling and the backbone area. For pulling into conduits, installation on cable trays or directly in the ground.
Construction
Cable core
Loose tube, gel-filled
Armour
Multi-functional, strengthened E-glass yarn, water-absorbent as strain relief and rodent protection
Cable jacket
PE jacket with imprint
Colour of jacket
Black
Transport and storage
–25°C to +70°C
Installation
–5°C to +50°C
Operation
–20°C to +60°C
min. bending radius
static dynamic
15 x outside diameter 20 x outside diameter
max. pull force
long-term
2500 N
max. crush resistance
long-term
3000 N/dm
Thermal properties Mechanical properties
Fire performance
Jacket is halogen-free
Note
The jacket material PE offers good protection against transversal water ingress.
No corrosive and toxic fumes
Max. number of fibers
12 24
www.leoni-fiber-optics.com
Outer Ø
Weight
Fire load
mm
kg/km
MJ/m
9.2 9.7
76 81
1.90 2.00
Strain relief elements and rodent protection
52
Outdoor Cables
Fiber Optic Cables
Rodent-protected, dry-core outdoor cable with stranded loose tubes
FiberConnect® A-DQ(ZN)B2Y nxm…
Outer jacket Water-absorbent fleece
Order no. 84 316 Standardisation DIN VDE 0888, Part 3 and IEC 60 794-3 Application Non-metallic, rugged outdoor cable. Installation-friendly because of the cable core kept free of grease. Installation in conduits, on cable trays or directly in the ground. Construction Cable core Glass fiber-reinforced central strength member with strand elements, designed as gel-filled loose tubes and if applicable dummy elements Water-absorbent fleece Armour Multi-functional, strengthened E-glass yarn as non-metallic strain relief elements and rodent protection Cable jacket PE jacket with hot-stamped marking Colour of jacket Black Thermal Transport and storage –40°C to +70°C properties Installation –5°C to +50°C Mechanical properties
Fire performance Note
Operation min. bending radius max. pull force max. crush resistance Jacket is halogen-free
Ripcord Loose tube, gel-filled Strain relief elements and rodent protection GFR central strength member
–40°C to +60°C static 15 x outside diameter dynamic 20 x outside diameter long-term 4000 N long-term 3000 N/dm
No corrosive and toxic fumes The jacket material PE offers good protection against transversal water ingress. Higher fiber numbers and pull forces on request. Also available with aluminium or corrugated steel tape.
Number of tubes
1xm 2xm 3xm 4xm 5xm 6xm 8xm 10 x m 12 x m
Max. number of fibers
Outer Ø
Weight
Fire load
mm
kg/km
MJ/m
12 24 36 48 60 72 96 120 144
11.4 11.4 11.4 11.4 11.4 12.3 13.7 15.2 17.0
115 115 115 115 115 135 160 190 230
4.1 4.1 4.1 4.1 4.1 4.5 5.0 5.5 6.2 www.leoni-fiber-optics.com
FiberConnect®
FiberTech®
FiberSwitch®
FiberSplit® Outdoor Cables
53
FO Cables
Grease-filled outdoor cable with stranded loose tubes
FiberConnect® A-DF(ZN)2Y nxm…
Outer jacket Water-absorbent fleece
Order no. 84 300 Standardisation DIN VDE 0888, Part 3 and IEC 60 794-3 Application Non-metallic, rugged outdoor cable for primary cabling and the backbone area. Installation in conduits, on cable trays or directly in the ground. Construction Cable core Glass fiber-reinforced central strength member with strand elements, designed as gel-filled loose tubes and if applicable dummy elements. Cable core filled with water-blocking gel. Strain relief element E-glass yarn Cable jacket PE jacket with hot-stamped marking Colour of jacket Black Thermal Transport and storage –40°C to +70°C properties Installation –5°C to +50°C Mechanical properties
Operation min. bending radius max. pull force
Fire performance Note
No corrosive and toxic fumes The jacket material PE offers good protection against transversal water ingress. Also available with aluminium or corrugated steel tape and copper elements.
Number of tubes
max. crush resistance Jacket is halogen-free
–40°C to +60°C static 15 x outside diameter dynamic 20 x outside diameter long-term ≤ 7 strand elements 3000 N > 7 strand elements 4000 N long-term 3000 N/dm
Max. number of fibers
1xm 2xm 3xm 4xm 5xm 6xm 8xm 10 x m 12 x m 16 x m
www.leoni-fiber-optics.com
12 24 36 48 60 72 96 120 144 192
Outer Ø
Weight
Fire load
mm
kg/km
MJ/m
11.4 11.4 11.4 11.4 11.4 12.3 13.7 15.2 17.0 16.8
120 120 120 120 120 135 170 200 240 255
4.3 4.3 4.3 4.3 4.3 4.6 5.1 5.7 6.5 7.4
Loose tube, gel-filled Core filling Strain relief elements GFR central strength member
54
Outdoor Cables
Fiber Optic Cables
Rodent-secure, grease-filled outdoor cable with stranded loose tubes
FiberConnect® A-DF(ZN)2YW2Y nxm…
Outer jacket Corrugated steel conduit
Order no. 84 310 Standardisation DIN VDE 0888, Part 3 and IEC 60 794-3 Application Rugged outdoor cable for primary cabling and the backbone area. Installation in conduits, on cable trays or directly in the ground. Construction Cable core Glass fiber-reinforced central strength member with strand elements, designed as gel-filled loose tubes and if applicable dummy elements. Cable core filled with water-blocking gel. Strain relief element E-glass yarn Inner jacket (black) PE jacket Corrugated steel conduit As highly effective rodent protection Cable jacket PE jacket with hot-stamped marking Colour of jacket Black Thermal Transport and storage –40°C to +70°C properties Installation –5°C to +50°C Mechanical properties
Operation min. bending radius max. pull force
Fire performance
Number of tubes
1xm 2xm 3xm 4xm 5xm 6xm 8xm 10 x m 12 x m 16 x m
max. crush resistance Jacket is halogen-free
Inner jacket Water-absorbent fleece Loose tube, gel-filled Strain relief elements GFR central strength member
–40°C to +60°C static 15 x outside diameter dynamic 20 x outside diameter long-term ≤ 7 strand elements 3000 N > 7 strand elements 4000 N long-term 3000 N/dm
No corrosive and toxic fumes
Max. number of fibers
12 24 36 48 60 72 96 120 144 192
Outer Ø
Weight
Fire load
mm
kg/km
MJ/m
16.7 16.7 16.7 16.7 16.7 18.8 18.8 21.8 21.8 21.8
275 275 275 275 275 335 335 335 370 380
10.4 10.4 10.4 10.4 10.4 12.0 12.0 12.5 13.1 13.8
www.leoni-fiber-optics.com
FiberConnect®
FiberTech®
FiberSwitch®
FiberSplit® Outdoor Cables
55
FO Cables
Transversely waterproof outdoor cable with central loose tube
FiberConnect® A-DQ(ZN)(L)2Y n…
Outer jacket Aluminium tape
Order no.
Ripcord
84 333
Loose tube, gel-filled
Standardisation DIN VDE 0888, Part 3 and IEC 60 794-3 Application
Light outdoor cable with diffusion barrier. Installation in cable ducts, on cable trays, in cable conduits or directly in the ground.
Construction
Cable core
Loose tube, gel-filled
Strain relief element
Non-metallic (E-glass yarn), water-absorbent
Aluminium tape
For transversal water resistance
Cable jacket
PE jacket with imprint
Colour of jacket
Black
Transport and storage
–25°C to +70°C
Installation
–5°C to +50°C
Thermal properties Mechanical properties
Fire performance
Operation
–20°C to +60°C
min. bending radius
static dynamic
15 x outside diameter 20 x outside diameter
max. pull force
long-term
2500 N
max. crush resistance
long-term
1000 N/dm
Jacket is halogen-free No corrosive and toxic fumes
Max. number of fibers
Outer Ø
Weight
Fire load
mm
kg/km
MJ/m
12 24
10.8 11.3
128 135
1.42 1.62
www.leoni-fiber-optics.com
Strain relief elements
56
Outdoor Cables
Fiber Optic Cables
Rodent-protected, transversely waterproof outdoor cable with central loose tube
FiberConnect® A-DQ(ZN)2YW2Y n…
Outer jacket Corrugated steel conduit
Order no.
Inner jacket
84 331
Loose tube, gel-filled
Standardisation DIN VDE 0888, Part 3 and IEC 60 794-3 Application
Rugged outdoor cable for installation in cable ducts, on cable trays, in conduits or directly in the ground
Construction
Cable core
Loose tube, gel-filled
Strain relief element
Non-metallic (E-glass yarn), water-absorbent
Inner jacket (black)
PE jacket
Strain relief elements
Corrugated steel conduit As highly effective rodent protection
Thermal properties Mechanical properties
Fire performance
Number of fibers
12 24
Outer jacket
PE jacket with imprint
Colour of jacket
Black
Transport and storage
–40°C to +70°C
Installation
–5°C to +50°C
Operation
–40°C to +60°C
min. bending radius
static dynamic
15 x outside diameter 20 x outside diameter
max. pull force
long-term
2500 N
max. crush resistance
long-term
2500 N/dm
Jacket is halogen-free No corrosive and toxic fumes
Outer Ø
Weight
Fire load
mm
kg/km
MJ/m
12.5 12.5
160 160
1.8 1.8
www.leoni-fiber-optics.com
FiberConnect®
FiberTech®
FiberSwitch®
FiberSplit® Outdoor Cables
57
FO Cables
Transversely waterproof outdoor cable with stranded loose tubes
FiberConnect® A-DQ(ZN)(L)2Y nxm…
Outer jacket Aluminium tape
Order no.
Ripcord
84 326
Water-absorbent fleece
Standardisation DIN VDE 0888, Part 3 and IEC 60 794-3 Application
Rugged outdoor cable with diffusion barrier. Installation in cable ducts, on cable trays, in cable conduits or directly in the ground.
Construction
Cable core
Glass fiber-reinforced central strength member with strand elements, designed as gel-filled loose tubes and if applicable dummy elements
Strain relief element
Non-metallic (E-glass yarn), water-absorbent
Aluminium tape
For transversal water resistance
Cable jacket
PE jacket with hot-stamped marking
Colour of jacket
Black
Transport and storage
–40°C to +70°C
Installation
–5°C to +50°C
Operation
–40°C to +60°C
min. bending radius
static dynamic
15 x outside diameter 20 x outside diameter
max. pull force
long-term
3000 N
max. crush resistance
long-term
1500 N/dm
Thermal properties Mechanical properties
Fire performance
Number of tubes
Jacket is halogen-free No corrosive and toxic fumes
Max. number of fibers
1xm 2xm 3xm 4xm 5xm 6xm 8xm 10 x m 12 x m
www.leoni-fiber-optics.com
12 24 36 48 60 72 96 120 144
Outer Ø
Weight
Fire load
mm
kg/km
MJ/m
12.1 12.1 12.1 12.1 12.1 13.0 14.4 15.9 17.7
140 140 140 140 140 160 200 240 280
4.9 4.9 4.9 4.9 4.9 5.6 5.9 6.4 7.2
Loose tube, gel-filled Strain relief elements GFR central strength member
58
Outdoor Cables
Fiber Optic Cables
Rodent-protected, transversely waterproof outdoor cable with stranded loose tubes
FiberConnect® A-DQ(ZN)W2Y nxm...
Outer jacket Corrugated steel conduit
Order no.
Ripcord
84 334
Loose tube, gel-filled
Standardisation DIN VDE 0888, Part 3 and IEC 60 794-3 Application
Rugged outdoor cable for installation in cable ducts, on cable trays, in conduits or directly in the ground
Construction
Cable core
Glass fiber-reinforced central strength member with strand elements, designed as gel-filled loose tubes and if applicable dummy elements
Strain relief element
Non-metallic (E-glass yarn), water-absorbent
Strain relief elements GFR central strength member
Corrugated steel conduit As highly effective rodent protection
Thermal properties Mechanical properties
Fire performance
Cable jacket
PE jacket with hot-stamped marking
Colour of jacket
Black
Transport and storage
–40°C to +70°C
Installation
–5°C to +50°C
Operation
–40°C to +60°C
min. bending radius
static dynamic
15 x outside diameter 20 x outside diameter
max. pull force
long-term
3000 N
max. crush resistance
long-term
2000 N/dm
Jacket is halogen-free No corrosive and toxic fumes
Number of tubes
Max. number of fibers
Outer Ø
Weight
Fire load
mm
kg/km
MJ/m
1xm 2xm 3xm 4xm 5xm
12 24 26 48 60
12.7 12.7 12.7 12.7 12.7
165 165 165 165 165
4.6 4.6 4.6 4.6 4.6
www.leoni-fiber-optics.com