Quick start The FLEXIFORCE GSM-02 works with contract as well as prepaid Sim cards. When using a prepaid card, notice that some providers let the call credit expire after a certain time. Some prepaid cards have to be upgraded once a year. Be sure the card is activated by your provider before you insert the card in the GSM-02. Also, disable the PINcode and the voicemail, than the GSM-02 is immediately ready for use. After connecting the voltage with the GSM-02 wait till the green LED is permanently on. The GSM-02 is gonna subscribe itself at the provider after connecting with the voltage. (It takes 1 or 2 minutes). WHEN THE GREEN LED IS PERMANENTLY ON, THE UNIT IS ACTIVATED. THERE CAN BE SWITCHED OR THERE CAN BE MADE A CONNECTION WITH THE SOFTWARE. A green LED that is permanently on indicates that the GSM-02 is ready for use. You can programm the GSM-02 by following commands. When the green LED has a interrupt sequence, the installed Sim card is not working or there is no contact with the provider of the Sim card. The red LED should have a slow interrupt sequence, this indicates that the unit is completely activated.
Key Features of the GSM-02 Terminal: Frequency bands: Power supply: Operating temperature: Dimensions: Weight: RoHS, WEEE:
Quad band: GSM 850/900/1800/1900MHz 5-24Vdc -20째C tot +70째C 98mm x 82m x 30m 160g All hardware components are fully compliant with the EU RoHS and WEEE Directives
connectors for power supply, interface and antennas: 1. 2. 3. 4. 5. 6. 7. 8. 9. 14
On/Off push button (Not in use with the GSM-02). SMA connector (female) for GSM antenna. Led's GSM and Unit. 9-pole (female) SUB-D plug for RS-232 serial interface. Option, Not in use. 24-pole GPIO 3mm Micro Mate-N-LOK connector for cable. 4-pole 3mm Micro Mate-N-LOK connector for power supply. 6-pole RJ11 plug (Not in use with the GSM-02) SIM card holder.
English English 4
5
2
1
3
Front view 7
6
Side A view 8
9 Side B view
Bottom view 15
Connections / technical data 220Vac
12Vdc
Red Black Yellow Green White
Topview
Red: Input / Output power 5-24 Vdc Black: Ground Yellow: IGNITION (not in use) Green: Normally open Relay White: Normally open Relay The power supply of the GSM-02 Terminal has to be a single voltage source of POWER 5V24Vdc capable of providing a peak during an active transmission. The GSM-02 Terminal is protected from supply voltage reversal. An internal fuse ensures an electrical safety according to EN60950. This fuse is not removable. A fast acting fuse 0.8A with melting is necessary to use with the GSM-02 Terminal at a 24V power supply system for vehicles. The power supply must be compliant with the EN60950 guidelines. REMARK: THE POWER SUPPLY IS INTERNALY CONNECTED FROM THE 4-PINS CONNECTOR TO THE 24-PINS CONNECTOR. IF YOU USE THE ADAPTER, YOU HAVE TO MAKE SURE THAT THE RED AND BLACK WIRE OF THE 24-PINS CONNECTOR DO NOT CONNECT!!
1 2 3 4
16
– Power – – GND –
4
3
2
1
13 – Normally open Relay 14 – Normally open Relay 23 – Ground 24 – Input / Output power 5—24 Vdc 9 – Ignition (not in use)
24
13
12
1
English English Supply voltage requirements: The DC power supply must be connected to the POWER input:
• • • • •
Input voltage range 5 - 24V DC Nominal voltage 12V DC Power Supply current rating: min. 1,2A @12V Power Supply ripple: max. 120mV Input current in idle mode: 20mA @ 12V
Internal relay:
• •
Maximum voltage = 30 Voltage @ max. 1 Ampere. The relay is normally open (NO).
Green LED displays the operating status of the network. Green LED status
Device status
Permanently on
Unit Ready for calls
Fast interrupt sequence (period 0,5 sec to 1 sec) Slowly interrupt sequence (between 0,3 sec to 3 sec) Permanently off
Error Unit receive a call Device off
Red LED displays the network status of the terminal. Red LED status
Device Status
Permanently on
A call is active
Fast interrupt sequence (period 0,5 sec to 1 sec)
Net search / Not registered / turning off
Slow interrupt sequence (period 0,3 sec to 3 sec)
Registered full service
Permanently off
Device off
Mechanical Characteristics Weight
160g
Dimensions (max) L x W x H
98 mm x 82mm x 30mm
Temperature range
-20°C to +70°C ambient temperature
Protection class
IP40 Avoid exposing GSM-02 Terminal to liquid or moisture.
Mechanical vibrations Amplitude
7.5mm at 5-200Hz sinus
Air humidity
5% - 85%
Class of flammability
UL94 HB
Casing material
PC/ABS Cycoloy 1200 HF 17
SMS Interface Description (List of SMS command for GSM-02) 1.1 Password Every SMS starts with p:password (standard 1234) Example: P.1234A.0541122333.0544455666 The command P. the password is 1234 the command A. is add new phone number to the list, in this example: 0541122333 en 0544455666 1.2 Add new phone number A.phone number,phone number,... Add new phone numbers to the phone list Example: P.1234A.0547512152.0525874525 Add 0547512152 and 0525874525 to the phone list. When more phone numbers have to be added, than put a DOT between the phone numbers, all SMS size can be used. 1.3 Add special new phone number AS.phone number.1.from time,to time week days Add one new special phone number to the special list with specific hours during the week days. The “from time” and the “to time” syntax is HHMM (with no spaces) Example 1: P.1234AS.058126248.1.1130.1540.135 Phone number 058126248 will be allowed to enter from 11:30 to 15:40 on Sunday, Tuesday and Thursday ( 1234567 weekdays starting with sunday) Example 2: P.1234AS.058126248.1.2300.0200.24 Phone number 058126248 will be allowed to enter from 23:30 to 02:00 on Monday and Wednesday. AS.phone number.3.Entries amount Add one new special phone number to the special list with limited entries amount. Example 1: P.1234AS.058126248.3.6 Phone number 058126248 will be allowed to enter 6 times Example 2: P.1234AS.058126248.3.11 Phone number 058126248 will be allowed to enter 11 times 1.4 Delete phone number D.phone number.phone number Delete phone numbers from regular phone list. Example: P.1234D.0542684284.0542358721 Phone number 0542684284 and 0542358721 deleted from the regular phone list, put comma between the phone numbers, can use all SMS size. When more phone numbers have to be added, than put a DOT between the phone numbers, all SMS size can be used. 1.5 Delete special phone number DS.phone number.phone number Delete phone numbers from special phone list. Example: P.1234DS.0542684284.0542358721 Phone number 0542684284 and 0542358721 deleted from the special phone list. When more phone numbers have to be added, than put a DOT between the phone numbers, all SMS size can be used.
18
English English 1.6 Set puls time (advanced) GOD.gate open delay Set the time of the pulse when calling to the unit, Maximum 60 seconds. Example: P.1234GOD.7 Set the gate open to 7 second delay. 1.7 Clock update CU Clock update, update the unit’s clock from the SMS send time. Example: P.1234CU 1.8 New password NP.new password Sets new password to the GSM-02 unit (the CSD password infect also). (be careful with it, when lost, the module have to get back to the manufacturer) Example: P.1234NP.4321 Change the password to 4321 1.9 Enable\Disable EN.1.0 Set the GSM-02 unit to enable or disable. Example 1: P.1234EN.1 Enable the GSM-02 unit Example 2: P.1234EN.0 Disable the GSM-02 unit. 1.10 Get unit information INFO Get information about the GSM-02 unit: Amount of numbers in the phone list Amount of numbers in the special phone list Reception level GSM-02 Unit Enable\Disable Example: P.1234INFO 1.11 Reset unit RESET Reset the GSM-02 unit from remote Example: P.1234RESET 1.12 Enable\Disable phone list OPEN.1.0 Enable\Disable phone list Example 1: P.1234OPEN.0 Enable phone list (Only phone numbers that are in de phone list can disable the GSM-02 unit) Example 2: P.1234OPEN.1 Disable phone list (All phone numbers can disable the GSM-02 unit).
19
Programming through software
5.
4.1
4.2
1.
3.
2.
Number
Description
1
Select connection COM 1-16 or Modem via CSD
2
Select language
3
Make connection to the unit via RS232
4.1
Save
4.2
Save as …
5
Open backup unit data from the PC file
Control the GSM-02 unit via RS232 or CSD
• • • • • •
20
To select the connection, push the phone icon number 1 on the top image. Select RS232 COM port from 1-16 or Modem for CSD connection. To make RS232 connection, push the icon number 3 on the top image. To select different language, push the icon number 2 on the top image. To save all unit data for backup, push the icon number 4 on the top image. To open backup unit data, push the icon number 5 on the top image.
English English
Add phone numbers
• • • • • • •
At this page enter all regular phone numbers that will activate the GSM-02.
•
To compare the phone number list that in the GSM-02 unit to the list on the PC file, use QUICK COMPARE box icon.
•
When new phone number enter to the software list on the index will appear the phone number with yellow marker, after loading the number to the GSM-02 unit the index marker will change to green.
•
The GET PHONE NUMBERS FROM UNIT box icon, allow to get phone numbers store on GSM-02 unit. When all numbers are green the process can be paused by clicking the STOP button.
• •
When looking for phone number or user name on the list, use the search boxes icon.
Those phone numbers don’t have time or date limitation. The list can hold 1600 phone numbers. To load new phone number use the 3 blank boxes USER DETAILS. After enter a phone number klick on SET. The new user is now on the list. To load long list of phone numbers and user names use INPORT FROM EXCEL Box icon, to make first time excel file use EXPORT TO EXCEL, this way the basic file with all column will be show.
Pay attention on the lower right side of this page there is massage box that give the software to GSM-02 unit connection status DISCONNECTED FROM UNIT or CONNECTED TO UNIT.
21
Add special phone numbers
• • • •
At this page enter all special phone numbers that will activate the GSM-02.
•
To load long list of phone numbers and user names use INPORT FROM EXCEL box icon, to first time excel file use EXPORT TO EXCEL, this way the basic file with all column will be show.
•
When new phone number enter to the software list on the index will appear the phone number with yellow marker, after loading the number to the GSM-02 unit the index marker will change to green.
•
To load new phone number to the GSM-02 unit us the SET box icon. The new user is now on the list.
22
Those phone numbers will have time or date limitation. The list can hold 400 phone numbers. To load new phone number use the 3 blank boxes on the lower left side of the page, then select what kind of limitation this phone number will have, there is 3 options FROM TIME TO TIME, FROM DATE TO DATE, ENTERY AMOUNT. For the FROM TIME TO TIME fill the week day and the time boxes. For the FROM DATE TO DATE file the date to date boxes. For the ENTERIES AMOUNT file the number of entries box.
English English
Miscellaneous
• • • •
At this page set all miscellaneous options that will activate the GSM-02.
•
SELF CLOCK UPDATE SMS, on unit power up, unit can get the time from self SMS, fill the SIM number on the unit to this box.
• • •
BAND SELECTION, 4 options for band selection for EUROPE and North America.
•
GATE DELAY, unit set to 3 second normally, for different time delay set this box.
UNIT NAME, for multi gate user, each unit have name. UNIT TIME, set time for special phone number and log. UNIT PASSWORD, change unit password, same password apply to SMS RS232 or CSD connection.
VERSION, get unit software version. RECEPTION, get unit reception level under 30% will consider low level, try to improve GSM antenna location for better reception.
23
Log
• • •
24
At this page each call will be register for log report. Log can be exported to excel file. Unit can save 1000 log lines.
English English
Safety recommandations READ CAREFULLY It is responsibility of the user to enforce the country regulation and the specific environment regulation. Do not disassemble the product; any mark of tampering will compromise the warranty validity. We recommend following the instructions of the hardware user guides for a correct wiring of the product. The product has to be supplied with a stabilized voltage source and the wiring has to be conforming to the security and fire prevention regulations. The product has to be handled with care, avoiding any contact with the pins because electrostatic discharges may damage the product itself. The use of this product may be dangerous and may have to be avoided in the following areas: Where it can interfere with other electronic devices and where there is risk of explosion such as gasoline stations, oil refineries, etc Same cautions have to be taken for the SIM, checking carefully the instruction for its use. Do not insert or remove the SIM when the product is in power saving mode. The system integrator is responsible of the functioning of the installation; therefore, care has to be taken to the external components of the module. Should there be any doubt, please refer to the technical documentation and the regulations in force. Every module has to be equipped with a original antenna with specific characteristics. The antenna has to be installed with care in order to avoid any interference with other electronic devices and has to guarantee a minimum distance from the body (20 cm). In case of this requirement cannot be satisfied, the system integrator has to assess the installation against the SAR regulation.