PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION
LEGEND PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION
S
5.30
MC25
4.50
ARC 13.68 S
S
6.3 1
S
S
29.98
4.50 S
MC25
5.00
S
5.00
25.49
7101
17.00
S
5.50
5.00
4.00
S
6.00
S
5.50
518.1 m²
0 6.0
PROJECT
PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.
0
5m
1 : 250 DATUM
DRAWN
CHECKED
AHD
AA
JT
Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com
TITLE
DISCLOSURE PLAN LOT NO. 7101
PROJECT CODE
DRAWING No.
ISSUE
AA006310
LOT-7101
01 C
PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION
5.30
PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION
LEGEND S
SA
MC25 4.50
SA
ARC 15.00 S
S
S
S
S
5.00
S
4.50 S
5.00
S
5.50
30.03
29.98
6.00
7102
S
6.00
S
5.50
431.1 m²
6.50
13.70
5.50
5.00
S
6.50
0
6.0
PROJECT
PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.
0
5m
1 : 250 DATUM
DRAWN
CHECKED
AHD
AA
JT
Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com
TITLE
DISCLOSURE PLAN LOT NO. 7102
PROJECT CODE
DRAWING No.
ISSUE
AA006310
LOT-7102
01 C
PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION
LEGEND PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION
S
5.30
SA
MC25 SA
ARC 11.00
S
S
S
S
S 5.50
5.50
6.00
30.03
30.04
6.00
5.50
7103
6.00
320.0 m²
6.50
6.50 6.77
3.56
5.50
6.50
6.0 0 PROJECT
PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.
0
5m
1 : 250 DATUM
DRAWN
CHECKED
AHD
AA
JT
Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com
TITLE
DISCLOSURE PLAN LOT NO. 7103
PROJECT CODE
DRAWING No.
ISSUE
AA006310
LOT-7103
01 C
PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION
5.30
PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION
LEGEND S
SA
MC25 SA 5.00
S
S
ARC 13.00
S
S
5.50
5.50
5.50
6.00
6.00
30.04
6.00 30.01
7104 379.6 m²
6.50
6.00
6.50
6.50
9.03
3.27
6.50
0
6.0
6.50
PROJECT
PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.
0
5m
1 : 250 DATUM
DRAWN
CHECKED
AHD
AA
JT
Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com
TITLE
DISCLOSURE PLAN LOT NO. 7104
PROJECT CODE
DRAWING No.
ISSUE
AA006310
LOT-7104
01 C
PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION
LEGEND PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION
S
5.30
5.00
MC25 5.00 5.00
ARC 13.00
S
S
5.50
5.50
5.50
6.00 6.00
6.00
30.02
30.01
6.00
7105
380.3 m²
6.50
6.50
6.50 6.50
8.46
3.89
6.50
(REFER TO C-
PROJECT
PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.
0
5m
1 : 250 DATUM
DRAWN
CHECKED
AHD
AA
JT
Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com
TITLE
DISCLOSURE PLAN LOT NO. 7105
PROJECT CODE
DRAWING No.
ISSUE
AA006310
LOT-7105
01 C
PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION
5.30
PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION
LEGEND S
5.00
MC25
5.00 S
5.50
5.00
S
ARC 11.00
5.00
5.50
5.50 5.50
6.00
6.00
6.00 6.00
29.98
30.02
7106 321.3 m²
6.50
6.50
6.50
6.50
10.41
(REFER TO C-FG-03 PACKAGE OF WOR PRECINCT F AND G STAGE 3 SHELL COVE
PROJECT
Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289
NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.
0
5m
1 : 250 DATUM
DRAWN
CHECKED
AHD
AA
JT
Tel: +61 (0)2 8907 9000 www.arcadis.com
TITLE
DISCLOSURE PLAN LOT NO. 7106
PROJECT CODE
DRAWING No.
ISSUE
AA006310
LOT-7106
01 C
PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION
LEGEND PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION
S
5.30
5.00
MC25
4.50
5.00
S
5.50
S
5.50
ARC 11.00
5.50
S
5.00
5.00
5.50
6.00 6.00
6.00
30.03
29.98
6.00
7107
320.5 m²
6.50
6.50
6.50
6.50
6.50
10.35
6.50 PROJECT
PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.
0
5m
1 : 250 DATUM
DRAWN
CHECKED
AHD
AA
JT
Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com
TITLE
DISCLOSURE PLAN LOT NO. 7107
PROJECT CODE
DRAWING No.
ISSUE
AA006310
LOT-7107
01 C
S
MC25
ARC 13.00 5.00
S
S
S
S
5.00
4.50
S
PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION
5.30
PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION
LEGEND
5.00 5.50
5.50
5.00
5.50
5.50
6.00 6.00
30.03
30.03
6.00
7108
379.6 m²
6.50
6.00
6.50 6.50 6.50
7.24
5.06
6.50
6.50 PROJECT
PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.
0
5m
1 : 250 DATUM
DRAWN
CHECKED
AHD
AA
JT
Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com
TITLE
DISCLOSURE PLAN LOT NO. 7108
PROJECT CODE
DRAWING No.
ISSUE
AA006310
LOT-7108
01 C
PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION
LEGEND PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION
S
5.30
MC25
4.50
ARC 13.00 S
S
S
S
S
5.00
4.50
S
5.00
5.00
5.50 5.50
30.03
6.00
30.03
5.50
7109 380.5 m² 6.00
6.00
6.50 6.50
6.50
5.80
6.55
6.50
6.50 PROJECT
PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.
0
5m
1 : 250 DATUM
DRAWN
CHECKED
AHD
AA
JT
Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com
TITLE
DISCLOSURE PLAN LOT NO. 7109
PROJECT CODE
DRAWING No.
ISSUE
AA006310
LOT-7109
01 C
PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION
LEGEND PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION
S
5.30
MC25
ARC 11.00 4.50
S
S
S
S
S
5.00
4.50
S
4.50
5.00
S
5.00 5.50 5.50
S
30.03
30.03
5.50
7110
6.00
319.4 m² S
6.00
6.00
S
6.50
2.23
8.05 6.50
PROJECT
PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.
0
5m
1 : 250 DATUM
DRAWN
CHECKED
AHD
AA
JT
Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com
TITLE
DISCLOSURE PLAN LOT NO. 7110
PROJECT CODE
DRAWING No.
ISSUE
AA006310
LOT-7110
01 C
PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION
5.30
PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION
LEGEND S
MC25
4.50
4.00
4.50 ARC 15.00
S
S
S
S
S
S
4.50
5.00
5.00
S
5.00
17.01
5.00
5.50
5.50
30.03
S
5.50
5.5
0
7111 6.00 S
6.00
5.50
S
13.00
6.00
0
6.0
13.94
6.0
0
6.50
PROJECT
PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.
0
5m
1 : 250 DATUM
DRAWN
CHECKED
AHD
AA
JT
Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com
TITLE
DISCLOSURE PLAN LOT NO. 7111
PROJECT CODE
DRAWING No.
ISSUE
AA006310
LOT-7111
01 C
PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION
LEGEND PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION
S
5.30
S
4.00
SA
0 4.0
MC25
4.00
4.00
ARC 25.17 S
S
S
S
SA
S
5
4.50
6.4
4.50
5.0
12.36
7112
0
S
496.2 m²
MC23
SA
17.01
S
5.00
5.5
0
29.67
S
S
5.50
0 6.0 PROJECT
PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.
0
5m
1 : 250 DATUM
DRAWN
CHECKED
AHD
AA
JT
Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com
TITLE
DISCLOSURE PLAN LOT NO. 7112
PROJECT CODE
DRAWING No.
ISSUE
AA006310
LOT-7112
01 C
PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION
S
0 4.0
SA
MC25
5.30
S
PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION
LEGEND
4.00
4.00 S
S
S
S
S
SA
4.50
4.50
SA
S
5.00
5.0
S
0
5.5
0
MC23
29.67
13.00
13.00
S
5.50
7113
S
385.7 m²
0 6.0 4.50
5.00
4.00
0 6.0
5.5 0
S
6.0 0
29.67
PROJECT
PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.
0
5m
1 : 250 DATUM
DRAWN
CHECKED
AHD
AA
JT
Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com
TITLE
DISCLOSURE PLAN LOT NO. 7113
PROJECT CODE
DRAWING No.
ISSUE
AA006310
LOT-7113
01 C
PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION
LEGEND PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION
S
5.30
S
S
5.50
0 6.0
5.5
MC23
4.50 13.00
0
5.00
S
0
6.0
7114
4.00
13.00
6.0 0
29.67
S
385.7 m²
S
5.0
0
4.50
5.5
0
SA
4.00
29.67
5.50
S
5.00 S
S
S
4.50 4.00 S
4.50
SA
BRIGANTINE DR (MC13) PROJECT
PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.
0
5m
1 : 250 DATUM
DRAWN
CHECKED
AHD
AA
JT
Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com
TITLE
DISCLOSURE PLAN LOT NO. 7114
PROJECT CODE
DRAWING No.
ISSUE
AA006310
LOT-7114
01 C
PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION
LEGEND PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION
S
S
5.30
4.50
5.00
5.5 0
0
4.00
S
6 .0 0
0 6.0 29.67
MC23
12.67
5.0 0
7115 492.6 m²
S
17.01
4.50
5.5
0
SA
4.00
S
6.0
5.50
S
5.00 S
ARCS25.17
S
4.50
4.00 S
SA
4.50
BRIGANTINE DR (MC13)
4.50 S
SA
4.00
PROJECT
PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.
0
5m
1 : 250 DATUM
DRAWN
AHD
AA
CHECKED
JT
Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com
TITLE
DISCLOSURE PLAN LOT NO. 7115
PROJECT CODE
AA006310
DRAWING No.
LOT-7115
ISSUE
01 C
PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION
LEGEND PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER 6.00HOUSE CONNECTION
S
S
5.30
5.50
S
6.00
0 6.0
16.18
13.00
S
6.0 0
6.50
0
30.01
S
5.5
0
6.0
7116 467.1 m²
S
17.01
5.5
0
6.00
5.50
5.50
5.00 5.00
S
S
5.00 S
S
S
S
ARC 15.00 4.50
S
4.50
SA
BRIGANTINE DR (MC13) 4.50 PROJECT
PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.
0
5m
1 : 250 DATUM
DRAWN
CHECKED
AHD
AA
JT
Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com
TITLE
DISCLOSURE PLAN LOT NO. 7116
PROJECT CODE
DRAWING No.
ISSUE
AA006310
LOT-7116
01 C
PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION
5.30
PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER 6.00 HOUSE CONNECTION
LEGEND S
6.50 6.50
13.85
6.50
30.01
30.02
6.50
7117
6.00402.5 m²
6.00
5.50
5.50
5.50 S
S
5.00
5.00 S
S
S
S
ARC 13.00
S
4.50
BRIGANTINE DR (MC13)
4.50 S
PROJECT
PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.
0
5m
1 : 250 DATUM
DRAWN
CHECKED
AHD
AA
JT
Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com
TITLE
DISCLOSURE PLAN LOT NO. 7117
PROJECT CODE
DRAWING No.
ISSUE
AA006310
LOT-7117
01 C
PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION
LEGEND PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION 6.50
S
5.30
6.50
13.79
6.50
6.50
30.02
30.02
6.50
7118
401.7 m²
6.00
6.00 6.00
5.50 5.50
S
S
S
S
S
5.00
S
ARC 13.00 5.00
BRIGANTINE DR (MC13)
PROJECT
PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.
0
5m
1 : 250 DATUM
DRAWN
CHECKED
AHD
AA
JT
Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com
TITLE
DISCLOSURE PLAN LOT NO. 7118
PROJECT CODE
DRAWING No.
ISSUE
AA006310
LOT-7118
01 C
PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION 6.50
LEGEND PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION
S
5.30
6.50
15.85
6.50
6.50
6.50
30.02
7119 30.02
462.5 m²
6.00
6.00
6.00
5.50
5.50
5.50 S
S
S
ARC 15.00
S
S
S
5.00 5.00
BRIGANTINE DR (MC13)
5.00
PROJECT
PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.
0
5m
1 : 250 DATUM
DRAWN
CHECKED
AHD
AA
JT
Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com
TITLE
DISCLOSURE PLAN LOT NO. 7119
PROJECT CODE
DRAWING No.
ISSUE
AA006310
LOT-7119
01 C
PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION
5.30
PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION 6.50
LEGEND S
6.50
13.85
6.50
30.02
6.50
30.02
7120 402.6 m²
6.00 6.00
5.50
S
6.00
5.50
5.50
S
S
S
S
S
ARC 13.00
5.00
5.00
BRIGANTINE DR (MC13) PROJECT
PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.
0
5m
1 : 250 DATUM
DRAWN
CHECKED
AHD
AA
JT
Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com
TITLE
DISCLOSURE PLAN LOT NO. 7120
PROJECT CODE
DRAWING No.
ISSUE
AA006310
LOT-7120
01 C
PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION
LEGEND PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION
S
5.30
6.50
6.50
11.73 6.50
6.50
30.02
30.02
6.00
7121 341.2 m²
6.00 6.00
5.50
S
5.50
5.50
S
S
S
ARC 11.00
S
S
5.00
5.00
BRIGANTINE DR (MC13)
PROJECT
PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.
0
5m
1 : 250 DATUM
DRAWN
CHECKED
AHD
AA
JT
Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com
TITLE
DISCLOSURE PLAN LOT NO. 7121
PROJECT CODE
DRAWING No.
ISSUE
AA006310
LOT-7121
01 C
PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION
LEGEND PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION
S
5.30
6.50
6.00
6.50
6.50
15.79
6.50
0
6.0
6.00 30.02
7122
30.02
461.6 m²
6.00 0 5.5 5.50 5.50
5.00
S
S
S
S
S
ARC 15.00
S
5.00
SA
BRIGANTINE DR (MC13) 4.50 PROJECT
PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.
0
5m
1 : 250 DATUM
DRAWN
CHECKED
AHD
AA
JT
Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com
TITLE
DISCLOSURE PLAN LOT NO. 7122
PROJECT CODE
DRAWING No.
ISSUE
AA006310
LOT-7122
01 C
S
6.00
PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION
5.30
PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION
LEGEND
6.50
5.00
5.50
17.26 6.50
0
6.0
30.02
30.03
6.00
7123
S
484.0 m²
5.5 0
5.50 5.00 S
S
S
S
S
S
ARC 15.00
4.50
S
SA
BRIGANTINE DR (MC13) 4.50
S
SA PROJECT
PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.
0
5m
1 : 250 DATUM
DRAWN
CHECKED
AHD
AA
JT
Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com
TITLE
DISCLOSURE PLAN LOT NO. 7123
PROJECT CODE
DRAWING No.
ISSUE
AA006310
LOT-7123
01 C
PROPOSED SEWER MANHOLE / MAINTENANCE SHAFT PROPOSED SEWER PROPOSED SEWER HOUSE CONNECTION
5.30
PROPOSED LOT GRADING CONTOUR PROPOSED LOT BOUNDARY PROPOSED STORMWATER PIPE & PIT PROPOSED EASEMENT FOR REPAIR 0.9m WIDE PROPOSED STORMWATER HOUSE CONNECTION
LEGEND
S
5.50
17.00
5.00
4.50
4.00
S
4.00
6.00
S
6.0
30.03
2 25.5 S
MC25
0
4.00
4.50
7124
S
491.1 m²
4.0
0
0
5.5
5.00
6.4
3 S
S
S
S
ARC 11.95 4.50
4.00
S
SA
BRIGANTINE DR (MC13) 4.50
PROJECT
PRECINCT F AND G STAGE 3 SHELL COVE NOTE: IT IS ACKNOWLEDGED THAT THE DIMENSION AND AREAS ARE SUBJECT TO CHANGE IN ACCORDANCE WITH THE REQUIREMENTS OF ANY RELEVANT AUTHORITY. THE PARTICULARS OF THIS PLAN ARE SUPPLIED FOR INFORMATION ONLY REPRESENTING THE FACTS AT TIME OF PRINTING AND MAY CHANGE. THE PARTICULARS SHALL NOT BE TAKEN AS A REPRESENTATION IN ANY RESPECT ON THE PART OF THE VENDOR OR ITS AGENT. AUTHORITIES SHOULD BE CONSULTED IN RELATION TO ANY LIMITATIONS OR REQUIREMENTS AS BUILDING RESTRICTIONS MAY APPLY.
0
5m
1 : 250 DATUM
DRAWN
CHECKED
AHD
AA
JT
Arcadis Australia Pacific Pty Limited Level 16, 580 GEORGE STREET SYDNEY NSW 2000 ABN 76 104 485 289 Tel: +61 (0)2 8907 9000 www.arcadis.com
TITLE
DISCLOSURE PLAN LOT NO. 7124
PROJECT CODE
DRAWING No.
ISSUE
AA006310
LOT-7124
01 C