Freedom AC Daikin 2015 Pricelist

Page 1

Daikin UK Price List 2015

Daikin UK Price List

2015

Air Conditioning Division Unit 5, St Georges Industrial Estate Goodwood Road, Eastleigh Hampshire SO50 4NT Telephone 02380 653283 Heat Pumps Division Unit 2, Warrior Park, Eagle Close School Lane, Chandlers Ford Hampshire SO53 4NF Telephone 02380 274833

Residential, Commercial and Industrial


Freedom Air Conditioning From its inception Freedom has had one goal in mind, a better service to contractors. It’s founders, directors and management team all started in contracting and as such understand the needs and demands that are put upon our customers. To ensure an outstanding service we have in-house design, dedicated technical support and experienced logistics teams all ready to be a natural extension to your business.

We are committed to making the life of our customers easier. Our technical support lines are manned by qualified field experienced service engineers and our sales teams (and indeed our owners) started on the tools and understand what you need. Air Conditioning Division Unit 5, St Georges Industrial Estate Goodwood Road, Eastleigh Hampshire SO50 4NT Telephone 02380 653283

Heat Pumps Division Unit 2, Warrior Park, Eagle Close School Lane, Chandlers Ford Hampshire SO53 4NF Telephone 02380 274833

Conditions Capacity Conditions

Seasonal Efficiency

Unit cooling and heating capacities shown within this price list are based on the following conditions:

Split and Sky Air

Nominal cooling Ambient = 35°C Internal = 27°C db 19°C wb

Nominal heating Ambient = 7°C db 6°C wb Internal = 20°C db

UK cooling Ambient = 30°C Internal = 22°C db 16°C wb

Systems of up to 12kW must now show Seasonal Efficiency Ratings instead of Nominal Efficiency Ratings. These ratings (SEER for cooling, SCOP for heating) represent how effective a system is throughout the year, and are in accordance with EN14825. For more information on Seasonal Efficiency, visit www.daikin.co.uk/seasonal-efficiency For Daikin UK, this means all our Split and Sky Air products up to 12kW display SEER and SCOP data along with Energy Label information and Annual Energy Consumption of the system. The AEC is based upon 500 hours use per year.

VRV (ESEER)

Heat Source

ESEER is defined as the European Seasonal Energy Efficiency Ratio and is a measure of the performance of the outdoor unit only.

Unless otherwise indicated, all units within this price list are air-cooled.

Nominal Efficiency This measure of efficiency is calculated by dividing the capacity output of a unit by the power required to deliver it. For cooling, this is expressed as EER, for heating as COP. Nominal efficiencies are used for systems above 12kW. It is not possible to compare nominal and Seasonal Efficiency ratings.


Daikin UK Price List 2015

Contents New for 2015

2

Split, Sky Air Heat Pumps

5

VRV

45

Ventilation

93

Heating

95

Refrigeration

141

Applied

147

Miscellaneous

161

Discount Rating Please insert your discounts here and then refer to the colour tabs on the edge of each page for reference.

Split, Sky Air Heat Pumps

VRV

Ventilation

MY DISCOUNT

MY DISCOUNT

MY DISCOUNT

%

%

%

Heating

Refrigeration

Applied

MY DISCOUNT

MY DISCOUNT

MY DISCOUNT

%

%

% Price List 2015

1


New for 2015 Mini-VRV VRV IV comes to the mini range

NEW

Low height mini range > Only 823mm high – simple installation > 4 & 5HP capacity > Variable Refrigerant Temperature > AHU and Air Curtain connection possibilities

COMING SOON

Extended capacity range > 8, 10 & 12HP twin fan horizontal airflow > For larger capacity Mini VRV installations Standard VRV IV 4/5/6HP ranges > Variable Refrigerant Temperature > LT Hot water / AHU / Air Curtain connectivity Page 68 / 69

Sky Air New Seasonal Inverter outdoor unit, adding an economically priced option to our unique Roundflow cassettes range: One unique Roundflow with 3 choices:

75m pipe run, pair, twin, triple. ECA eligible

50m pipe run, pair, twin, triple

NEW FOR 2015

30m pipe run, pair only Page 25 / 26 / 27

Daikin is first to the market with R32 systems

NEW FOR 2015

A range of split systems using the next generation of refrigerants offering: > Lower global warming potential > Higher efficiencies > Lower refrigerant charge 3 types of wall mount available: > Ururu Sarara > Emura > FTXM High Inverter

Page 7 / 8 / 9 / 10

2

Residential, Commercial and Industrial


FNQ-A / FXNQ-A vertical chassis unit

NEW COMING SOON

> > > >

Slim width chassis for installation under windows or in bulkheads New 2kW to 6kW model for connection to Split / Sky or Multi External Static Pressure of up to 44Pa VRV replaces UK.FXDQ model Page 33 / 52

FBQ-D / FXSQ-A Medium Static Ducted units > > > >

NEW FOR 2015

Upgrade to existing range of ducted units Reduced unit height to 245mm External Static Pressure of 150Pa VRV range extended to include 15 class

Page 30 / 31 / 32 / 50

Multi-boxes for VRV-Q and VRV-W

NEW FOR 2015

> Upgrade to VRV-Q and VRV-W outdoor units > Allows connection to the versatile range of VRV IV single & multi BS boxes > VRV IV range of single & multi BS box becomes standard range Page 83

EKMBDXA Modbus Interface

NEW FOR 2015

> I ntegrated control system for seamless connection between Sky Air or VRV equipment and BMS systems > Communication via Modbus RS485 > Connects directly to Daikin DIII-net protocol

Page 86

NEW FOR 2015

Simplified remote control solution for hotels > > > >

Wall mounted remote with or without heat /cool button Stylish chrome or brass facia options available BRP7A51 adaptor connects fancoil to key-card and window contacts BRP7A51 implements control strategy based on key-card or window status Page 85

Heating

NEW

Our Residential, Commercial & Industrial Price list now includes details of our domestic heating range including: > Altherma air-to-water heat pumps – including Monobloc > Altherma Hybrid heat pump system > Solar thermal & underfloor heating products

FOR 2015

Page 100 - 140

NEW COMING SOON

Applied > New Air Cooled Multi-Scroll Chiller ranges > New Water Cooled Multi-Scroll Chiller ranges

Price List 2015

3



SPLIT, SKY AIR HEAT PUMPS

Daikin UK Price List 2015

Split, Sky Air Heat Pumps Sky Air Roundflow Cassette 6 Enhanced Capital Allowance (ECA) Scheme 6 Another First From Daikin: R32 7 Pair Applications 8 Wall Mounted Split Systems

8

Floor Standing Split Systems

16

Flexi Type Split Systems

20

Ceiling Mounted Split Systems

21

Under Ceiling Cassette Split Systems

24

Cassette Split Systems

25

Ducted Split Systems

30

Multi Applications 36 Multi Split Systems

36

Twin, Triple, Double Twin Systems

38

Scotland Region 0845 641 9330

Northern Region 0845 641 9340

Midlands Region 0845 641 9370

Western Region 0845 641 9320

North London 0845 641 9360

South London 0845 641 9355


SPLIT, SKY AIR HEAT PUMPS

Sky Air Roundflow Cassette One cassette, 3 options: Daikin’s Roundflow Cassette range has a solution for all your needs: > Price > Performance > Highest Efficiency

> > > > >

Pair applications 30m pipe run -5 / -15°C operating range in cooling / heating A/A Energy Labels R22 replace technology

FCQG-F Series cassette BYFQ140D Roundflow decoration panel BRC1E52 remote control

> > > > >

Pair, twin, triple, double twin applications 50m pipe run -15 / -15°C operating range in cooling / heating A+/A+ Energy Labels R22 replace technology

> > > > > >

Pair, twin, triple, double twin applications 75m pipe run -15 / -20°C operating range in cooling / heating Up to A++/A+ Energy Labels All capacities ECA Eligible R22 replace technology

Enhanced Capital Allowance (ECA) Scheme

The Enhanced Capital Allowance (ECA) scheme provides businesses with enhanced tax relief for investment in energy-saving equipment that meets specified Government criteria. It allows 100% of the investment to be written off against taxable profit in the year the investment is made.

The Energy Technology List (ETL) is a definitive list of all the products that qualify for the ECA, typically by meeting or exceeding efficiency standards. For DX, the list covers approximately the top 20% of air conditioning systems and is updated regularly to ensure that it includes the most energy efficient products currently available.

Daikin now has a website that allows customers to check whether selected equipment is efficient enough to be eligible to claim Enhanced Capital Allowances. Go to www.daikin.co.uk/eca to check: > Split > Sky Air > VRV The website also allows you to create a Certificate of Eligibilty for your equipment selection that can be used to support a claim for ECA.

Certain types of equipment are listed on the ECA website. To check eligibility of the following equipment types, please go to www.etl.decc.gov.uk/etl/site.htm > Biddle Air Curtains (Split and VRV) > Ventilation (VAMs) > Control Options (RTD20) > Chillers The ETL website should also be used to check equipment eligibility for Split, Sky Air & VRV equipment purchasesd before August 2014.

6

Residential, Commercial and Industrial


SPLIT, SKY AIR HEAT PUMPS

Another First From Daikin: R32 Reasons for change

Daikin products using R32

There are a number of options for the next generation refrigerant gas, to meet future legislation and reduce the environmental impact of air conditioning, heat pumps and refrigeration. The choices are generally accepted to be R32, R410A, HFO blends, CO2, and hydrocarbons, including R290 and R600.

The 2015 product line up includes 3 ranges that will use R32. These will be offered along side our full range of R410a products and have Efficiencies of up to A+++ in heating & cooling:

Daikin’s work with R32

Ururu Sarara (FTXZ)

Because of its superior energy efficiency and low GWP, R32 is Daikin’s preferred next generation refrigerant for air conditioners and heat pumps. Its first domestic air conditioners using R32 were introduced to Japan in 2012 and there have been sales in excess of 4 million systems.

Emura (FTXJ)

R32 in brief R32 is already used in HVAC equipment, as it makes up 50% of R410A. It has a global warming potential (GWP) of 675, which is one third that of R410A (2,088). It’s more energy efficient, resulting in a lower refrigerant charge and the potential to manufacture smaller units. As a single component refrigerant, it is also easier to reuse and recycle. Like many low GWP refrigerants, R32 is mildly flammable, requiring some new tools and procedures during installation. It is also easier to handle because it doesn’t fractionate when being charged as a vapour.

Wall mount (FTXM)

> Ururu Sarara (FTXZ) – see page 8 > Emura (FTXJ) – see page 9 > Wall mount (FTXM) – see page 10

Installation and equipment Installation of R32 systems is very similar to R410A systems, although slightly different equipment is required. These include: > Gauge manifold > Recovery pump > Electronic leak tester

Using R32 in a split system delivers: > Lower GWP > Higher efficiencies > Smaller refrigerant charge

These are available from a number of key manufacturers. Please contact your local stockist.

Refrigerant Charge

Refrigerant performance 1.6

1.2

Tooling

R410A

R32

Manifold Scale Vacuum pump Leak detector Recovery unit Ventilation * Warnings Recovery bottle

Current tool Current Current Current Current Recommended Blue marks 40 bar, right thread

Different scale Current Current Different Different Necessary (fan) Blue+Red marks (p16) 48 bar, left thread

* when installed in a plant room

R22 0.8

R-410A R32

0.4

0 2.5

3.0

3.5

Energy Efficiency Ratio Refrigerant

GWP

R22 R410A R32

1,910 2,088 675

Contact Daikin Training to arrange an R32 Training Course covering: > Daikin’s range of R32 equipment > Installation, equipment & handing of R32 www.daikintraining.co.uk

Based on 3.5kW Wall Mount

Price List 2015

7


SPLIT, SKY AIR HEAT PUMPS

FTXZ-N / RXZ-N

Wall Mounted (with R32 refrigerant) Indoor Units Capacity

Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency

Air Flow Rate Dimensions

Weight Sound Pressure Sound Power

UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Low Height Width Depth High / Low / S Low

kW kW kW kW kW kWh kW kWh

kWh m3/min mm mm mm kg dBA dBA

Outdoor Units Dimensions Weight Electrical Details

Interconnection Wiring Piping Connections Pipework

Sound Pressure Sound Power

FTXZ25N

FTXZ35N

FTXZ50N

2.79 2.39 2.50 3.60 A+++ 2.50 9.54 92 A+++ 3.50 5.90 831 6.10 / 5.80 A/A 205 10.7 / 5.3

3.90 2.88 3.50 5.00 A+++ 3.50 9.00 136 A+++ 4.50 5.73 1100 5.30 / 5.00 A/A 330 12.1 / 5.6 295 798 372 15 42 / 27 / 19 57

5.58 3.77 5.00 6.30 A+++ 5.00 9.40 203 A+++ 5.60 5.50 1427 4.55 / 4.47 A/A 550 15.0 / 6.6

15 47 / 30 / 23 60

RXZ35N

RXZ50N

15 38 / 26 / 19 54 RXZ25N

Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High

mm kg A A A inches m m m g/m kg dBA dBA

Trade Fan Coil Price Trade Condensing Unit Price Total System Price

1.34 46 59

693 x 795 x 300 50kg 1ph 2.80 4.4 16 3+E / 1.5 1/4 / 3/8 20 10 8 Databook 1.34 48 61

£361.00 £982.00 £1,343.00

£424.00 £1,136.00 £1,560.00

1.80 2.8 16 1/4 / 3/8 20 10 8

4.80 6.2 16 1/4 / 3/8 20 10 8 1.34 49 63 £556.00 £1,196.00 £1,752.00

FTXZ / RXZ systems use R32 refrigerant

Accessories:

Notes:

Accessory Ref

Description

Trade Price

BRP069A42 KRP413A1S KRP928A2S KLIC-DD RTD-RA KPMH974A42 KPMH974A402 KPMJ942A4 KPMJ983A4L KPMH950A41 UK.CWB90-2 UK.DT1

Wi-fi adaptor to connection on on-line controller Adaptor PCB for remote on/off control - constant/pulse contact Adaptor PCB for interface to Daikin centralised control systems KNX interface for Split type systems Adaptor PCB for Modbus connection and/or extended system functions Hose for humidification (10m length) Humidification hose extension set (2m length) Humidification hose extension joints (10 pieces) L-shaped joints for humidification hose (10 pieces) L-shaped cuffs for humidification hose (10 pieces) Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm

£50.00 £75.00 £132.00 £164.00 £151.00 TBC TBC TBC TBC TBC £37.00 £56.00

i) All fan coils supplied with infrared remote control ARC477A1 ii) The supplied humidifying hose is 8m in length iii) Minimum ambient operating temperatures:

RXZ

Cooling

Heating

-20°C

-20°C

Features: > Complete climate control withe dehumidification, ventilation, air purification and heating & cooling in ONE system > Very high efficiency solution to comfort, thanks to Ururu technology & R32 refrigerant > Self cleaning filters ensure optimum air quality & efficiency of operation > Infrared remote controller with backlit display, or optional Online Control via smartphone or tablet > 3 area intelligent eye ensures air is directed away from people in the room, and switches unit to energy-efficient mode if no-one is detected

8

Residential, Commercial and Industrial

I W I- F O L TR CO N A P P V IA


SPLIT, SKY AIR HEAT PUMPS

FTXJ / RXJ

Emura (with R32 refrigerant) Indoor Units Capacity

Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency

Air Flow Rate Dimensions

Weight Sound Pressure Sound Power

Matt Crystal White UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Low Height Width Depth High / Low

kW kW kW kW kW kWh kW kWh

kWh m3/min mm mm mm kg dBA dBA

Outdoor Units Dimensions Weight Electrical Details

Interconnection Wiring Piping Connections Pipework

Sound Pressure Sound Power

FTXJ25LW

FTXJ35LW

FTXJ50LW

FTXJ20LS

FTXJ25LS

FTXJ35LS

FTXJ50LS

2.25 1.84 2.00 2.50 A++ 2.30 8.73 92 A++ 2.10 4.61 638 A/A 4.61 / 5.00 248 8.8 / 4.4*

2.35 1.88 2.50 3.40 A++ 2.40 8.64 97 A++ 2.70 4.60 822 A/A 4.73 / 4.57 254 8.8 / 4.4*

3.42 2.51 3.50 4.00 A++ 3.50 7.19 170 A++ 3.00 4.60 913 A/A 4.09 / 4.04 428 11 / 4.8*

4.69 3.09 5.00 5.80 A++ 4.80 7.02 239 A+ 4.60 4.28 1505 A/A 3.35 / 3.65 716 11.3 / 6.8*

2.25 1.84 2.00 2.50 A++ 2.30 8.73 92 A++ 2.10 4.61 638 A/A 4.61 / 5.00 248 8.8 / 4.4*

2.35 1.88 2.50 3.40 A++ 2.40 8.64 97 A++ 2.70 4.60 822 A/A 4.73 / 4.57 254 8.8 / 4.4*

3.42 2.51 3.50 4.00 A++ 3.50 7.19 170 A++ 3.00 4.60 913 A/A 4.09 / 4.04 428 11 / 4.8*

4.69 3.09 5.00 5.80 A++ 4.80 7.02 239 A+ 4.60 4.28 1505 A/A 3.35 / 3.65 716 11.3 / 6.8*

12 38 / 25 54

12 45 / 26 59

12 45 / 35 60

RXJ25L

RXJ35L

303 998 212 12 38 / 25 54 RXJ20L

Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High

ECA Eligible Trade Fan Coil Price Trade Condensing Unit Price Total System Price

mm kg A A A inches m m m g/m kg dBA dBA

Brushed Aluminium

FTXJ20LW

2.70* 2.8* 16 1/4 / 3/8 20 15 10 0.90 46 61

303 998 212

12 38 / 25 54

12 45 / 26 59

RXJ25L

RXJ35L

550 x 765 x 285 34 1ph 2.80* 4.80* 4.4* 5.5* 16 16 3+E / 1.5 1/4 / 3/8 1/4 / 3/8 20 20 15 15 10 10 Databook 0.90 0.90 46 48 61 63

12 45 / 35 60

12 38 / 25 54

RXJ50L

RXJ20L

735 x 825 x 315 47 6.20* 7.4* 20

2.70* 2.8* 16

1/4 / 1/2 30 20 10

1/4 / 3/8 20 15 10

1.1 48 63

1.05 46 61

550 x 765 x 300 34 1ph 2.80* 4.80* 4.4* 5.5* 16 16 3+E / 1.5 1/4 / 3/8 1/4 / 3/8 20 20 15 15 10 10 Databook 1.05 1.05 46 48 61 63

RXJ50L 735 x 825 x 315 48 6.20* 7.4* 20 1/4 / 1/2 30 20 10 1.6 48 63

£289.00 £526.00 £815.00

£304.00 £555.00 £859.00

£341.00 £644.00 £985.00

£450.00 £868.00 £1,318.00

£345.00 £526.00 £871.00

£362.00 £555.00 £917.00

£406.00 £644.00 £1,050.00

£537.00 £868.00 £1,405.00

FTXJ / RXJ systems use R32, for R410a version see page 11

Accessories:

Notes:

Accessory Ref

Description

Trade Price

BRC944 BRCW901A03 BRCW901A08 BRP069A41 KRP413A1S KRP928A2S KLIC-DD RTD-RA UK.CWB90-2 UK.DT1 UK.CGS UK.CGM

Optional Wired Remote controller 3m connection cable for BRC944 8m connection cable for BRC944 Wifi adaptor for connection to on-line controller Adaptor PCB for remote on/off control - constant/pulse contact Adaptor PCB for interface to Daikin centralised control systems KNX interface for Split type systems Adaptor PCB for Modbus connection and/or extended system functions Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm Condensing Unit Guard size 20-35 Condensing Unit Guard size 42-71

£64.00 £17.00 £22.00 £40.00 £75.00 £132.00 £164.00 £151.00 £37.00 £56.00 £214.00 £296.00

i) All fan coil units standard with auto restart after power failure ii) All fan coils supplied as standard with infrared remote controller ARC466A1 iii) Wired controller, KLIC-DI and RTD-RA options cannot be combined iv) Minimum ambient operating temperatures:

RXJ

Cooling

Heating

-10°C

-15°C

v) * Provisional data

Features: > Designed in Europe, perfect for UK climates, Daikin Emura creates the optimum comfort zone all year round > It represents a perfect marriage of style and substance, of form and function, of intelligent heating and efficient cooling > Stylish, low-profile design > Wireless remote controller with weekly timer: provides a 7-day schedule timer, enabling daily or weekly programming. Up to 4 actions per day possible > Night set mode: prevents sudden changes in room temperature by gently adjusting the temperature before the system stops > Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room > 2-area intelligent eye: air flow is sent to a zone other than where the occupants are located at that moment > Presence Sensor switches to energy saving mode if room is unoccupied after 20 mins > Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting > Fan speed: 5 fan speeds can be selected, high to super low

I W I- F O L TR CO N A P P V IA

Price List 2015

9


SPLIT, SKY AIR HEAT PUMPS

FTXM-K / RXM

Wall Mounted – Inverter (with R32 refrigerant) Indoor Units Capacity

Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency

Air Flow Rate Dimensions

Weight Sound Pressure Sound Power

UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Low Height Width Depth High / Low

kW kW kW kW kW kWh kW kWh

kWh m3/min mm mm mm kg dBA dBA

Outdoor Units Dimensions Weight Electrical Details

Interconnection Wiring Piping Connections Pipework

Sound Pressure Sound Power

FTXM20K

FTXM25K

FTXM35K

FTXM42K

FTXM50K

1.95* 1.65* 2.00 2.50 A++ 2.00 7.79 90 A++ 2.30 4.77 675 A/A 4.53 / 4.55 221 8.8 / 4.7 289 780 215 8 40 / 24 58

2.44* 1.82* 2.50 3.40 A++ 2.50 8.3 105 A++ 2.50 4.78 733 A/A 4.34 / 4.52 288 9.1 / 5 289 780 215 8 41 / 25 58

3.42* 2.56* 3.50 4.00 A++ 3.50 7.81 157 A++ 3.60 4.85 1039 A/A 4.09 / 4.76 428 11.2 / 5.8 298 900 215 11 45 / 29 59

4.11* 2.85* 4.20 5.40 A++ 4.20 7.14 206 A+ 4.00 4.38 1278 A/A 3.46 / 4.12 607 11.2 / 7 298 900 215 11 45 / 33 59

4.56* 3.14* 5.00 5.80 A++ 5.00 7.22 242 A+ 4.60 4.55 1416 A/A 3.40 / 4.00 738 11.9 / 7.4 298 900 215 11 46 / 34 60

RXM25L

RXM35L

RXM42L

RXM50L

RXM20L Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High

mm kg A A A inches m m m g/m kg dBA dBA

ECA Eligible Trade Fan Coil Price Trade Condensing Unit Price Total System Price

0.9 46 61

550 x 765 x 285 34 1ph 2.90 3.3* 10* 3+E / 1.5 1/4 / 3/8 20 15 10 Databook 0.9 46 61

£170.00 £480.00 £650.00

£182.00 £524.00 £706.00

£208.00 £608.00 £816.00

£234.00 £686.00 £920.00

£324.00 £764.00 £1,088.00

34 2.40 2.8* 10* 1/4 / 3/8 20 15 10

735 x 825 x 300 34

47

47 1ph

4.60 4.3* 10*

6.00 6.6* 20*

6.70 6.8* 20*

1/4 / 3/8 20 15 10

1/4 / 3/8 30 20 10

0.9 48 63

0.9 48 63

1.0 48 63

3+E / 2.5 1/4 / 1/2 30 20 10 Databook

FTXM / RXM systems use R32, for R410a version see page 12

Notes:

Accessories: Accessory Ref

Description

Trade Price

KRP980A1 BRC944 BRP069A42 BRCW901A03 BRCW901A08 KRP928A2S KLIC-DD RTD-RA UK.CWB90-2 UK.DT1 UK.CGS UK.CGM

S21 adaptor for FTXM20 & 25K for ALL control options Optional Wired Remote controller Wifi adaptor for connection to on-line controller 3m connection cable for BRC944 8m connection cable for BRC944 Adaptor PCB for interface to Daikin centralised control systems KNX interface for Split type systems Adaptor PCB for Modbus connection and/or extended system functions Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm Condensing Unit Guard size 20-35 Condensing Unit Guard size 42-71

£50.00 £64.00 £50.00 £17.00 £22.00 £132.00 £164.00 £151.00 £37.00 £56.00 £214.00 £296.00

i) All fan coil units standard with auto restart after power failure ii) All fan coils supplied as standard with infrared remote controller iii) Wired controller, KLIC-DI and RTD-RA options cannot be combined iv) Minimum ambient operating temperatures: RXM

Cooling

Heating

-10°C

-15°C

v) * Provisional data

Features: > Wireless remote controller with weekly timer: provides a 7-day schedule timer, enabling daily or weekly programming. Up to 4 actions per day possible > Night set mode: prevents sudden changes in room temperature by gently adjusting the temperature before the system stops I W I- F O L > Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room TR CO N A P P IA V > 2-area intelligent eye: (35~50 K class) air flow is sent to a zone other than where the occupants are located at that moment > Presence Sensor switches to energy saving mode if room is unoccupied after 20 mins > Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting > Fan speed: 5 fan speeds can be selected, high to super low

10

Residential, Commercial and Industrial


SPLIT, SKY AIR HEAT PUMPS

Emura

Wall Mounted – Inverter Indoor Units Capacity

Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency

Air Flow Rate Dimensions

Weight Sound Pressure Sound Power

Matt Crystal White UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Low Height Width Depth High / Low

kW kW kW kW kW kWh kW kWh

kWh m3/min mm mm mm kg dBA dBA

Outdoor Units Dimensions Weight Electrical Details

Interconnection Wiring Piping Connections Pipework

Sound Pressure Sound Power

FTXG25LW

FTXG35LW

FTXG50LW

FTXG20LS

FTXG25LS

FTXG35LS

FTXG50LS

2.25 1.84 2.00 2.50 A+++ 2.30 8.52 94 A++ 2.10 4.60 639 4.59 / 5 A/A 250 8.8 / 4.4

2.35 1.88 2.50 3.40 A+++ 2.40 8.50 99 A++ 2.70 4.60 821 4.59 / 4.42 A/A 261 8.8 / 4.4

3.42 2.51 3.50 4.00 A++ 3.50 7.00 175 A++ 3.00 4.60 913 3.97 / 4.06 A/A 441 11 / 4.8

4.69 3.09 5.00 5.80 A++ 4.80 6.70 251 A+ 4.60 4.24 1519 3.53 / 3.65 A/A 680 11.3 / 6.8

2.25 1.84 2.00 2.50 A+++ 2.30 8.52 94 A++ 2.10 4.60 639 4.59 / 5 A/A 250 8.8 / 4.4

2.35 1.88 2.50 3.40 A+++ 2.40 8.50 99 A++ 2.70 4.60 821 4.59 / 4.42 A/A 261 8.8 / 4.4

3.42 2.51 3.50 4.00 A++ 3.50 7.00 175 A++ 3.00 4.60 913 3.97 / 4.06 A/A 441 11 / 4.8

4.69 3.09 5.00 5.80 A++ 4.80 6.70 251 A+ 4.60 4.24 1519 3.53 / 3.65 A/A 680 11.3 / 6.8

12 38 / 25 54

12 45 / 26 59

12 45 / 35 60

RXG25L

RXG35L

303 998 212 12 38 / 25 54 RXG20L

Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High

ECA Eligible Trade Fan Coil Price Trade Condensing Unit Price Total System Price

mm kg A A A inches m m m g/m kg dBA dBA

Silver

FTXG20LW

2.70 2.8 16 1/4 / 3/8 20 15 10 1.05 46 61

303 998 212

12 38 / 25 54

12 45 / 26 59

RXG25L

RXG35L

550 x 765 x 285 35 1ph 2.80 4.80 4.4 5.5 16 16 3+E / 1.5 1/4 / 3/8 1/4 / 3/8 20 20 15 15 10 10 20 1.05 1.05 46 48 61 63

12 45 / 35 60

12 38 / 25 54

RXG50L

RXG20L

735 x 825 x 300 48 6.20 7.4 20 3+E / 2.5 1/4 / 1/2 30 20 10

2.70 2.8 16 1/4 / 3/8 20 15 10

1.6 48 63

1.05 46 61

550 x 765 x 285 35 1ph 2.80 4.80 4.4 5.5 16 16 3+E / 1.5 1/4 / 3/8 1/4 / 3/8 20 20 15 15 10 10 20 1.05 1.05 46 48 61 63

RXG50L 735 x 825 x 300 48 6.20 7.4 20 3+E / 2.5 1/4 / 1/2 30 20 10 1.6 48 63

£262.00 £478.00 £740.00

£276.00 £504.00 £780.00

£310.00 £585.00 £895.00

£409.00 £789.00 £1,198.00

£313.00 £478.00 £791.00

£329.00 £504.00 £833.00

£369.00 £585.00 £954.00

£488.00 £789.00 £1,277.00

Accessories:

Notes:

Accessory Ref

Description

Trade Price

BRC944 BRCW901A03 BRCW901A08 BRP069A41 KRP413A1S KRP928A2S KLIC-DD RTD-RA UK.CWB90-2 UK.DT1 UK.CGS UK.CGM

Optional Wired Remote controller 3m connection cable for BRC944 8m connection cable for BRC944 Wifi adaptor for connection to on-line controller Adaptor PCB for remote on/off control - constant/pulse contact Adaptor PCB for interface to Daikin centralised control systems KNX interface for Split type systems Adaptor PCB for Modbus connection and/or extended system functions Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm Condensing Unit Guard size 20-35 Condensing Unit Guard size 42-71

£64.00 £17.00 £22.00 £40.00 £75.00 £132.00 £164.00 £151.00 £37.00 £56.00 £214.00 £296.00

i) All fan coil units standard with auto restart after power failure ii) All fan coils supplied as standard with infrared remote controller ARC466A1 iii) Wired controller, KLIC-DI and RTD-RA options cannot be combined iv) Minimum ambient operating temperatures:

RXG

Cooling

Heating

-10°C

-15°C

Features: > Designed in Europe, perfect for UK climates, Daikin Emura creates the optimum comfort zone all year round > It represents a perfect marriage of style and substance, of form and function, of intelligent heating and efficient cooling > Stylish, low-profile design > Wireless remote controller with weekly timer: provides a 7-day schedule timer, enabling daily or weekly programming. Up to 4 actions per day possible > Night set mode: prevents sudden changes in room temperature by gently adjusting the temperature before the system stops > Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room > 2-area intelligent eye: air flow is sent to a zone other than where the occupants are located at that moment > Presence Sensor switches to energy saving mode if room is unoccupied after 20 mins > Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting > Fan speed: 5 fan speeds can be selected, high to super low > Suitable for multi model applications > Re-use of existing R22 and R407C piping possible

I W I- F O L TR CO N A P P V IA

Price List 2015

11


SPLIT, SKY AIR HEAT PUMPS

FTXS-K/G

Wall Mounted – Inverter Indoor Units Capacity

Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency

Air Flow Rate Dimensions

Weight Sound Pressure Sound Power

UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Low Height Width Depth High / Low

kW kW kW kW kW kWh kW kWh

kWh m3/min mm mm mm kg dBA dBA

Outdoor Units Dimensions Weight Electrical Details

Interconnection Wiring Piping Connections Pipework

Sound Pressure Sound Power

Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High

mm kg A A A inches m m m g/m kg dBA dBA

ECA Eligible Trade Fan Coil Price Trade Condensing Unit Price Total System Price

FTXS-K series

FTXS-G series

FTXS20K

FTXS25K

FTXS35K

FTXS42K

FTXS50K

FTXS60G

FTXS71G

1.95 1.65 2.00 2.50 A++ 2.00 7.40 95 A++ 2.30 4.77 675 4.65 / 4.72 A/A 215 8.8 / 4.7 289 780 215 8 40 / 24 58

2.44 1.82 2.50 3.40 A++ 2.50 7.90 111 A++ 2.50 4.78 732 4.39 / 4.67 A/A 285 9.1 / 5 289 780 215 8 41 / 25 58

3.42 2.56 3.50 4.00 A++ 3.50 7.47 164 A++ 3.60 4.85 1039 4.07 / 4.76 A/A 430 11.2 / 5.8 298 900 215 11 45 / 29 59

4.11 2.85 4.20 5.40 A++ 4.20 6.80 216 A+ 4.00 4.20 1334 3.56 / 4.12 A/A 590 11.2 / 7 298 900 215 11 45 / 33 59

4.56 3.14 5.00 5.80 A++ 5.00 6.80 257 A+ 4.60 4.20 1535 3.55 / 4 A/A 705 11.9 / 7.4 298 900 215 11 46 / 34 60

5.86 3.87 6.00 7.00 A 6.00 5.58 376 A 4.80 3.89 1728 3.02 / 3.43 B/B 995 16 / 11.3 290 1050 250 12 45 / 36 61

6.94 4.65 7.10 8.20 A 7.10 5.23 475 A 6.50 3.50 2593 3.02 / 3.22 B/C 1175 17.2 / 11.5 290 1050 250 12 46 / 37 62

RXS20L3

RXS25L3

RXS35L3

RXS42L

RXS50L

RXS60L

550 x 765 x 285 34

550 x 765 x 285

735 x 825 x 300

1.0 46 59

34 1ph 3.10 3.3 10 3+E / 1.5 1/4 / 3/8 20 15 10 20 1.0 46 59

£154.00 £436.00 £590.00

£165.00 £476.00 £641.00

£189.00 £552.00 £741.00

£212.00 £623.00 £835.00

£294.00 £694.00 £988.00

2.30 2.8 10 1/4 / 3/8 20 15 10

34

39

4.10 4.3 10

5.70 6.6 20

1/4 / 3/8 20 15 10

1/4 / 3/8 20 15 10

1.2 48 61

1.3 48 61

47 1ph 6.30 6.8 20 3+E / 2.5 1/4 / 1/2 30 20 10 20 1.7 48 62

Accessories:

RXS71F8

48

770 x 900 x 320 71

8.80 9.4 20

10.49 11.7 20

1/4 / 1/2 30 20 10

1/4 / 5/8 30 20 10

1.5 49 62

2.3 52 65

£300.00 £740.00 £1,040.00

£400.00 £1,013.00 £1,413.00

Notes:

Accessory Ref

Description

Trade Price

KRP980A1 BRC944 BRP069A42 BRCW901A03 BRCW901A08 KRP928A2S KLIC-DD RTD-RA UK.CWB90-2 UK.DT1 UK.DT2 UK.CGS UK.CGM

S21 adaptor for FTXS20K & 25K for ALL control options Optional Wired Remote controller Wifi adaptor for connection to on-line controller 3m connection cable for BRC944 8m connection cable for BRC944 Adaptor PCB for interface to Daikin centralised control systems KNX interface for Split type systems Adaptor PCB for Modbus connection and/or extended system functions Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm Condensate drip tray for use with Sky Air ODU - tray width 1100mm Condensing Unit Guard size 20-35 Condensing Unit Guard size 42-71

£50.00 £64.00 £50.00 £17.00 £22.00 £132.00 £164.00 £151.00 £37.00 £56.00 £59.00 £214.00 £296.00

i) All fan coil units standard with auto restart after power failure ii) All fan coils supplied as standard with infrared remote controller iii) Wired controller, KLIC-DI and RTD-RA options cannot be combined iv) FTXS-K and FTXS-G have different style casing v) Minimum ambient operating temperatures: RXS

Cooling

Heating

-10°C

-15°C

Features: > Wireless remote controller with weekly timer: provides a 7-day schedule timer, enabling daily or weekly programming. Up to 4 actions per day possible > Night set mode: prevents sudden changes in room temperature by gently adjusting the temperature before the system stops I > Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room W I- F O L TR CO N A P P > 2-area intelligent eye: (35~50 K class) air flow is sent to a zone other than where the occupants are located at that moment V IA > Presence Sensor switches to energy saving mode if room is unoccupied after 20 mins > Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting > Fan speed: 5 fan speeds can be selected, high to super low > Suitable for multi model applications > Re-use of existing R22 and R407C piping possible

12

Residential, Commercial and Industrial


SPLIT, SKY AIR HEAT PUMPS

FTX-J3/G

Wall Mounted – Low Inverter Indoor Units Capacity

Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency

Air Flow Rate Dimensions

Weight Sound Pressure Sound Power

UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Low Height Width Depth High / Low

kW kW kW kW kW kWh kW kWh

kWh m3/min mm mm mm kg dBA dBA

Outdoor Units Dimensions Weight Electrical Details

Interconnection Wiring Piping Connections Pipework

Sound Pressure Sound Power

FTX20J3

FTX25J3

FTX35J3

FTX50GV

FTX60GV

FTX71GV

1.95 1.60 2.00 2.50 A++ 2.00 6.10 115 A+ 2.20 4.26 723 3.64 / 4.24 A/A 275 9.1 / 5.9 283 770 198 7 39 / 25 55

2.44 1.78 2.50 2.80 A++ 2.50 6.10 143 A+ 2.40 4.10 820 3.54 / 4.10 A/A 365 9.2 / 6 283 770 198 7 40 / 26 55

3.07 2.11 3.30 3.50 A++ 3.30 6.10 189 A+ 2.80 4.10 956 3.40 / 3.80 A/A 490 9.3 / 6.1 283 770 198 7 41 / 27 58

4.89 3.32 5.00 5.80 A+ 5.00 5.63 311 A+ 4.60 4.08 1578 3.23 / 3.63 A/A 775 14.7 / 10.3 290 1050 238 12 43 / 34 59

5.86 3.88 6.00 7.00 A 6.00 5.37 391 A 4.80 3.88 1730 3.02 / 3.43 B/B 995 16.2 / 11.4 290 1050 238 12 45 / 36 60

6.94 4.46 7.10 8.20 B 7.10 4.97 500 A 6.20 3.81 2276 3.02 / 3.22 B/C 1175 17.4 / 11.6 290 1050 238 12 46 / 37 63

RX25K

RX35K

RX50GV

RX60GVB

RX20K Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High

Trade Fan Coil Price Trade Condensing Unit Price Total System Price

mm kg A A A inches m m m g/m kg dBA dBA

0.7 46 60

550 x 658 x 275 28 1ph 3.49 3.7 16 3+E / 1.5 1/4 / 3/8 15 12 10 20.0 0.7 46 60

£123.00 £364.00 £487.00

£136.00 £389.00 £525.00

28 2.49 2.7 16 1/4 / 3/8 15 12 10

RX71GVB

735 x 825 x 300 30

48

4.99 5.0 16

6.75 7.4 20

1/4 / 3/8 15 12 10

1/4 / 1/2 30 20 10

1.0 48 62

1.5 47 61

47 1ph 8.62 9.4 20 3+E / 2.5 1/4 / 1/2 30 20 10 20.0 1.5 49 63

£154.00 £453.00 £607.00

£250.00 £590.00 £840.00

£255.00 £629.00 £884.00

Accessories:

770 x 900 x 320 71 10.40 11.7 20 1/4 / 5/8 30 20 10 2.3 52 65 £341.00 £904.00 £1,245.00

Notes:

Accessory Ref

Description

Trade Price

KRP980A1 BRC944 BRP069A42 UK.CWB90-2 UK.DT1 UK.DT2 UK.CGS UK.CGM

S21 adaptor for ALL control options on FTX-J3 / FTX-GV series Optional Wired Remote controller Wifi adaptor for connection to on-line controller Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm Condensate drip tray for use with Sky Air ODU - tray width 1100mm Condensing Unit Guard size 20-35 Condensing Unit Guard size 42-71

£50.00 £64.00 £50.00 £37.00 £56.00 £59.00 £214.00 £296.00

i) All fan coils supplied as standard with infrared remote controller ii) All fan coil units standard with auto restart after power failure iii) Minimum ambient operating temperatures: RX-K RX-GV(B)

Cooling

Heating

+10°C -10°C

-15°C -15°C

Features: > Wireless remote controller with daily timer > Night set mode: prevents sudden changes in room temperature by gently adjusting the temperature before the system stops > Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room > Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting > Fan speed: 5 fan speeds can be selected, high to super low > Suitable for multi model applications > Re-use of existing R22 and R407C piping possible I W I- F O L TR CO N A P P V IA

Price List 2015

13


SPLIT, SKY AIR HEAT PUMPS

FAQ-C / RZQG

Wall Mounted – Seasonal Smart Inverter Indoor Units Capacity

Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency

Air Flow Rate Dimensions

Weight Sound Pressure Sound Power

Single Phase UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Low Height Width Depth High / Low

kW kW kW kW kW kWh kW kWh

kWh m3/min mm mm mm kg dBA dBA

Outdoor Units Dimensions Weight Electrical Details

Interconnection Wiring Piping Connections Pipework

Sound Pressure Sound Power

Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High

mm kg A A A inches m m m g/m kg dBA dBA

ECA Eligible

3 Phase

FAQ71C

FAQ100C

FAQ71C

FAQ100C

7.76 5.32 6.80 7.50 A++ 6.80 6.51 365 A+ 6.33 4.02 2204 3.4 / 3.7 A/A 1000 18 / 14 290 1050 238 13 45 / 40 58

10.80 7.44 9.50 10.80 A++ 9.50 6.11 544 A+ 10.20 4.01 3561 3.62 / 3.61 A/A 1315 26 / 19 340 1200 240 17 49 / 41 62

7.76 5.32 6.80 7.50 A++ 6.80 6.51 365 A+ 6.33 4.02 2204 3.4 / 3.7 A/A 1000 18 / 14 290 1050 238 13 45 / 40 58

10.80 7.44 9.50 10.80 A++ 9.50 6.11 544 A+ 10.20 4.01 3561 3.62 / 3.61 A/A 1315 26 / 19 340 1200 240 17 49 / 41 62

RZQG71L9V1

RZQG100L9V1

RZQG71L8Y1

RZQG100L8Y1

990 x 940 x 320 78 1ph 8.17 4 20

1430 x 940 x 320 102

990 x 940 x 320 80

1430 x 940 x 320 101

10.75 4 32

3.07 4 16

3ph

3+E / 1.5 3/8 / 5/8 3/8 / 5/8 50 75 30 30 30 30 Refer to Installation Manual 2.9 4.0 48 50 64 66

3+E / 1.5 3/8 / 5/8 3/8 / 5/8 50 75 30 30 30 30 Refer to Installation Manual 2.9 4.0 48 50 64 66

Trade Fan Coil Price Trade Condensing Unit Price Total System Price

£749.00 £1,191.00 £1,940.00

£808.00 £1,514.00 £2,322.00

£749.00 £1,227.00 £1,976.00

Accessories:

£808.00 £1,584.00 £2,392.00

Notes:

Accessory Ref

Description

Trade Price

BRC7EB518 KRP4A53/UK.FB2 RTD-NET/UK.FB2 RTD-10/UK.FB2 RTD-20/UK.FB2 KLIC-DI KRCS01-4 K.RSS RS-SE UK.CWB90-2 UK.CWB140-2 UK.DT2 UK.CGM UK.CGL

Wireless remote controller Unit/Group adaptor PCB for remote on/off, status indication and temperature setting Modbus Interface PCB for Sky Air and VRV Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock Energy control PCB for Sky Air and VRV KNX Interface for Sky Air and VRV systems Remote room mounted temperature sensor Wireless room mounted temperature sensor and receiver Service and Configuration Tool for K.RSS Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU Condensate drip tray for use with Sky Air ODU - tray width 1100mm Condensing Unit Guard size 42-71 Condensing Unit Guard size 100-140 including RXYSQ

£152.00 £92.00 £190.00 £235.00 £251.00 £185.00 £52.00 £89.00 £93.00 £37.00 £46.00 £59.00 £296.00 £354.00

i) All fan coils supplied as standard with BRC1E52A wired remote controller with 7-day time clock ii) BRC7EB518 Trade price will be reduced by £76.00 if ordered instead of the BRC1E52A iii) All fan coil units standard with auto restart after power failure iv) Minimum ambient operating temperatures: RZQG RZQSG

Features: > Fan speed: 3 fan speeds available on all capacities > Automatic airflow volume control sets fan speed based on difference between set and room temperatures > Dry programme: Daikin’s special dry programme reduces humidity in the rooms without variations in internal temperature > Comms, computer and server room cooling possible with EDP setting (Seasonal Smart) > Selectable evaporating & condensing temperature for greater operating efficiency and application flexibility (Seasonal Smart) > DIII net compatibility as standard > Seasonally Efficient Inverter Technology gives up to 25% better efficiency than inverter technology > Re-use of existing R22 and R407C piping possible. (See R22 Replacement leaflet) > Suitable for Twin, Triple and Double Twin applications

14

4.04 4 20

Residential, Commercial and Industrial

Cooling

Heating

-15°C -15°C

-20°C -15°C


SPLIT, SKY AIR HEAT PUMPS

FAQ-C / RZQSG

Wall Mounted – Seasonal Classic Inverter Indoor Units Capacity

Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency

Air Flow Rate Dimensions

Weight Sound Pressure Sound Power

Single Phase UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Low Height Width Depth High / Low

kW kW kW kW kW kWh kW kWh

kWh m3/min mm mm mm kg dBA dBA

Outdoor Units Dimensions Weight Electrical Details

Interconnection Wiring Piping Connections Pipework

Sound Pressure Sound Power

Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High

Trade Fan Coil Price Trade Condensing Unit Price Total System Price

mm kg

3 Phase

FAQ71C

FAQ100C

FAQ100C

7.28 4.99 6.80 7.50 A+ 6.80 6.05 393 A+ 6.00 3.90 2155 3.21 / 3.61 A/A 1059 18 / 14 290 1050 238 13 45 / 40 58

10.80 7.44 9.50 10.80 A+ 9.50 5.61 592 A+ 6.81 4.01 2377 3.01 / 3.41 B/B 1580 26 / 19 340 1200 240 17 49 / 41 62

10.80 7.44 9.50 10.80 A+ 9.50 5.61 592 A+ 6.81 4.01 2377 3.01 / 3.41 B/B 1580 26 / 19 340 1200 240 17 49 / 41 62

RZQSG71L3V1

RZQSG100L9V1

RZQSG100L8Y1

770 x 900 x 320 67

990 x 940 x 320 81

2.75 49 65

2.9 53 69

990 x 940 x 320 82 3ph 4.86 4 20 3+E / 1.5 3/8 / 5/8 50 30 30 Refer to Installation Manual 2.9 53 69

£749.00 £820.00 £1,569.00

£808.00 £1,135.00 £1,943.00

£808.00 £1,170.00 £1,978.00

1ph A A A

8.66 4 20

12.91 4 32 3+E / 1.5

inches m m m g/m kg dBA dBA

3/8 / 5/8 50 30 30

3/8 / 5/8 50 30 30 Refer to Installation Manual

Price List 2015

15


SPLIT, SKY AIR HEAT PUMPS

Nexura

Floor Mounted – Inverter Indoor Units Capacity

Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency

Air Flow Rate Dimensions

Weight Sound Pressure Sound Power

UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Low Height Width Depth High / Low

kW kW kW kW kW kWh kW kWh

kWh m3/min mm mm mm kg dBA dBA

Outdoor Units Dimensions Weight Electrical Details

Interconnection Wiring Piping Connections Pipework

Sound Pressure Sound Power

FVXG25K

FVXG35K

FVXG50K

2.44 1.93 2.50 3.40 A++ 2.50 6.53 134 A++ 2.80 4.65 842 -/-/8.9 / 5.3 600 950 215 22 38 / 26 52

3.42 2.37 3.50 4.50 A++ 3.50 6.48 189 A+ 3.10 4.00 1087 -/-/9.1 / 5.3 600 950 215 22 39 / 27 52

4.81 3.17 5.00 5.80 A+ 5.00 5.41 324 A+ 4.60 4.18 1543 -/-/10.6 / 7.3 600 950 215 22 44 / 36 58

RXG25L Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High

mm kg A A A

RXG35L

RXG50L

550 x 765 x 300 34

735 x 825 x 315 48

34 1ph 4.64 5.5 10

2.68 4.4 10

6.04 7.4 20 3+E / 2.5 1/4 / 1/2 30 20 10

3+E / 1.5 inches m m m g/m kg dBA dBA

ECA Eligible

1/4 / 3/8 20 15 10 1.05 46 61

1/4 / 3/8 20 15 10 20 1.05 48 63

1.60 48 63

Trade Fan Coil Price Trade Condensing Unit Price Total System Price

£631.00 £504.00 £1,135.00

£679.00 £585.00 £1,264.00

Accessories:

£744.00 £789.00 £1,533.00

Notes:

Accessory Ref

Description

Trade Price

BRC944 BRP089A42 BRCW901A03 BRCW901A08 KRP413A1S KRP928A2S KLIC-DD RTD-RA BKS028 UK.CWB90-2 UK.DT1 UK.CGS UK.CGM

Optional Wired Remote controller Wifi adaptor for on-line controller 3m connection cable for BRC944 8m connection cable for BRC944 Adaptor PCB for remote on/off control - constant/pulse contact Adaptor PCB for interface to Daikin centralised control systems KNX interface for Split type systems Adaptor PCB for Modbus connection and/or extended system functions Leg for floor-standing installation Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm Condensing Unit Guard size 20-35 Condensing Unit Guard size 42-71

£64.00 £50.00 £17.00 £22.00 £75.00 £132.00 £164.00 £151.00 £393.00 £37.00 £56.00 £214.00 £296.00

i) All fan coils supplied as standard with infrared remote controller ARC466AZ ii) All fan coil units standard with auto restart after power failure iii) Wired controller, KLIC-DI and RTD-RA options cannot be combined iv) Minimum ambient operating temperatures:

RXG

Cooling

Heating

-10°C

-15°C

Features: > Radiant Heat panel provides radiator-like warming at the touch of a button > Energy efficient units: full range A class energy labels > Wireless remote controller provides a 7-day schedule timer, enabling the user to program the air conditioning daily or weekly, with up to 4 actions per day > Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room > Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting I W I- F O L > Extremely quiet in operation: down to 19dBA sound pressure level TR CO N A P P IA V > Night set mode: prevents any sudden change in room temperature by gently raising/lowering the temperature before the system stops, so you can sleep more comfortably > Vertical auto swing system automatically makes the louvers move up and down, creating an even distribution of air through the room to ensure a harmonized temperature > Flexible installation: Can be installed against a wall, recessed or standing on the floor (installation leg required, see accessories list). Ideal for installation beneath a window > Suitable for multi model applications > Re-use of existing R22 and R407 piping possible

16

Residential, Commercial and Industrial


SPLIT, SKY AIR HEAT PUMPS

FVXS

Floor Mounted – Inverter Indoor Units Capacity

Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency

Air Flow Rate Dimensions

Weight Sound Pressure Sound Power

UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Low Height Width Depth High / Low High

kW kW kW kW kW kWh kW kWh

kWh m3/min mm mm mm kg dBA dBA

Outdoor Units Dimensions Weight Electrical Details

Interconnection Wiring Piping Connections Pipework

Sound Pressure Sound Power

Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High High

Trade Fan Coil Price Trade Condensing Unit Price Total System Price

mm kg A A A

FVXS25F

FVXS35F

FVXS50F

2.44 1.87 2.50 3.40 A+ 2.50 5.74 152 A+ 2.60 4.56 798 4.39 / 4.42 A/A 285 8.2 / 4.8 600 700 210 14 38 / 26 52

3.42 2.34 3.50 4.50 A+ 3.50 5.60 219 A 2.90 3.93 1033 3.43 / 3.78 A/A 510 8.5 / 4.9 600 700 210 14 39 / 27 52

4.89 3.21 5.00 5.80 A+ 5.00 5.89 297 A 4.20 3.80 1546 3.23 / 3.63 A/A 775 10.7 / 7.8 600 700 210 14 44 / 36 60

RXS25L3

RXS35L3

RXS50L

550 x 765 x 285 34

550 x 765 x 285 34 1ph 4.70 4.3 10

735 x 825 x 300 47

3.30 3.3 10

6.80 6.8 20 3+E / 2.5 1/4 / 1/2 30 20 10

3+E / 1.5 inches m m m g/m kg dBA dBA

1/4 / 3/8 20 15 10 1.0 46 59

1/4 / 3/8 20 15 10 20 1.2 48 61

£523.00 £476.00 £999.00

£564.00 £552.00 £1,116.00

Accessories:

1.7 48 62 £616.00 £694.00 £1,310.00

Notes:

Accessory Ref

Description

Trade Price

BRP089A42 KRP413A1S KRP928A2S KLIC-DD RTD-RA UK.CWB90-2 UK.DT1 UK.CGS UK.CGM

Wifi adaptor for on-line controller Adaptor PCB for remote on/off control - constant/pulse contact Adaptor PCB for interface to Daikin centralised control systems KNX interface for Split type systems Adaptor PCB for Modbus connection and/or extended system functions Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm Condensing Unit Guard size 20-35 Condensing Unit Guard size 42-71

£50.00 £75.00 £132.00 £164.00 £151.00 £37.00 £56.00 £214.00 £296.00

i) All fan coils supplied as standard with infrared remote controller ii) All fan coil units standard with auto restart after power failure iii) Wired controller, KLIC-DI and RTD-RA options cannot be combined iv) Minimum ambient operating temperatures: RXS

Cooling

Heating

-10°C

-15°C

Features: > Extremely quiet, energy efficient and can be installed against the wall or recessed > Wireless remote controller with weekly timer: provides a 7-day schedule timer, enabling daily or weekly programming. Up to 4 actions per day possible > Night set mode: prevents any sudden change in room temperature by gently raising/lowering the temperature before the system stops > Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting > Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room > Dry programme: Daikin’s special dry programme reduces humidity in the rooms without variations in internal temperature > Suitable for multi model applications I W I- F O L TR > Re-use of existing R22 and R407C piping possible CO N A P P IA V

Price List 2015

17


SPLIT, SKY AIR HEAT PUMPS

FVQ-C / RZQG

Floor Mounted – Seasonal Smart Inverter Indoor Units Capacity

Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency

Air Flow Rate Dimensions

Weight Sound Pressure Sound Power

Single Phase UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Low Height Width Depth High / Low

kW kW kW kW kW kWh kW kWh

kWh m3/min mm mm mm kg dBA dBA

Outdoor Units Dimensions Weight Electrical Details

Interconnection Wiring Piping Connections Pipework

Sound Pressure Sound Power

3 Phase

FVQ71C

FVQ100C

FVQ125C

FVQ140C

FVQ71C

FVQ100C

FVQ125C

FVQ140C

7.76 5.32 6.80 7.50 A++ 6.80 6.31 377 A+ 6.33 4.05 2188 3.37 / 3.64 A/A 1010 18 / 14 1850 600 270 39 43 / 38 55

10.80 7.44 9.50 10.80 A+ 9.50 5.61 592 A+ 11.30 4.20 3766 3.81 / 4.14 A/A 1245 28 / 22 1850 600 350 47 50 / 44 62

13.60 9.30 12.00 13.50 A+ 12.00 5.61 748 A 11.30 3.87 4087 3.21 / 3.7 A/A 1870 28 / 24 1850 600 350 47 51 / 46 63

14.90 10.25 13.40 15.50 3.21 / 3.61 A/A 2085 30 / 26 1850 600 350 47 53 / 48 65

7.76 5.32 6.80 7.50 A++ 6.80 6.31 377 A+ 6.33 4.05 2188 3.37 / 3.64 A/A 1010 18 / 14 1850 600 270 39 43 / 38 55

10.80 7.44 9.50 10.80 A+ 9.50 5.61 592 A+ 11.30 4.20 3766 3.81 / 4.14 A/A 1245 28 / 22 1850 600 350 47 50 / 44 62

13.60 9.30 12.00 13.50 A+ 12.00 5.61 748 A 11.30 3.87 4087 3.21 / 3.7 A/A 1870 28 / 24 1850 600 350 47 51 / 46 63

14.90 10.25 13.40 15.50 3.21 / 3.61 A/A 2085 30 / 26 1850 600 350 47 53 / 48 65

RZQG71L9V1 RZQG100L9V1 RZQG125L9V1 RZQG140L9V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1 Height x Width x Depth

Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High

mm kg

990 x 940 x 320 78

1430 x 940 x 320 102

A A A

8.26 4 20

10.18 4 32

1430 x 940 x 320 102

1430 x 940 x 320 102

990 x 940 x 320 80

1430 x 940 x 320 101

15.29 4 32

17.04 4 32

3.11 4 16

3.83 4 20

3/8 / 5/8 75 30 30

3/8 / 5/8 50 30 30

4.0 52 69

2.9 48 64

1ph

inches m m m g/m kg dBA dBA

ECA Eligible

3/8 / 5/8 50 30 30 2.9 48 64

£999.00 £1,191.00 £2,190.00

3+E / 1.5 3/8 / 5/8 3/8 / 5/8 75 75 30 30 30 30 Refer to Installation Manual 4.0 4.0 50 51 66 67

5.75 4 20

6.41 4 20

3+E / 1.5 3/8 / 5/8 3/8 / 5/8 75 75 30 30 30 30 Refer to Installation Manual 4.0 4.0 50 51 66 67

3/8 / 5/8 75 30 30 4.0 52 69

£1,098.00 £1,514.00 £2,612.00

£1,211.00 £1,666.00 £2,877.00

£1,302.00 £1,901.00 £3,203.00

£999.00 £1,227.00 £2,226.00

Accessories:

£1,098.00 £1,584.00 £2,682.00

£1,211.00 £1,743.00 £2,954.00

£1,302.00 £2,002.00 £3,304.00

Notes:

Accessory Ref

Description

Trade Price

KRP4A53/UK.FB2 RTD-NET/UK.FB2 RTD-10/UK.FB2 RTD-20/UK.FB2 KLIC-DI UK.CWB90-2 UK.CWB140-2 UK.DT2 UK.CGM UK.CGL

Unit/Group adaptor PCB for remote on/off, status indication and temperature setting Modbus Interface PCB for Sky Air and VRV Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock Energy control PCB for Sky Air and VRV KNX Interface for Sky Air and VRV systems Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU Condensate drip tray for use with Sky Air ODU - tray width 1100mm Condensing Unit Guard size 42-71 Condensing Unit Guard size 100-140 including RXYSQ

£92.00 £190.00 £235.00 £251.00 £185.00 £37.00 £46.00 £59.00 £296.00 £354.00

i) All fan coils supplied as standard with BRC1E52A wired remote controller with 7-day time clock ii) All fan coil units standard with auto restart after power failure iii) Minimum ambient operating temperatures: RZQG RZQSG

Features: > Seasonally Efficient Inverter Technology gives up to 25% better efficiency than Inverter Technology > Vertical air flow pattern can be adjusted manually to match requirements in different sized interiors or irregularly shaped rooms > A wired BRC1E52A remote controller is mounted on the front of the unit (standard) > Controllable horizontal air-blow patterns, via remote control > Very efficient for use in rooms with high ceilings > Fan speed: 2 fan speeds can be selected, high or low > Re-use of existing R22 and R407C piping possible > Comms, computer and server room cooling possible with EDP setting (Seasonal Smart) > Selectable evaporating & condensing temperature for greater operating efficiency (Seasonal Smart) > DIII net compatibility as standard

18

1430 x 940 x 320 101

3ph

Trade Fan Coil Price Trade Condensing Unit Price Total System Price

1430 x 940 x 320 101

Residential, Commercial and Industrial

Cooling

Heating

-15°C -15°C

-20°C -15°C


SPLIT, SKY AIR HEAT PUMPS

FVQ-C / RZQSG

Floor Mounted – Seasonal Classic Inverter Indoor Units Capacity

Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency

Air Flow Rate Dimensions

Weight Sound Pressure Sound Power

Single Phase UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Low Height Width Depth High / Low

kW kW kW kW kW kWh kW kWh

kWh m3/min mm mm mm kg dBA dBA

Outdoor Units Dimensions Weight Electrical Details

Interconnection Wiring Piping Connections Pipework

Sound Pressure Sound Power

3 Phase

FVQ71C

FVQ100C

FVQ125C

FVQ140C

FVQ100C

FVQ125C

FVQ140C

7.28 4.99 6.80 7.50 A 6.80 5.50 433 A 6.33 3.86 2296 3.21 / 3.61 A/A 1059 18 / 14 1850 600 270 39 43 / 38 53

10.80 7.44 9.50 10.80 A 9.50 5.50 604 A+ 7.60 4.01 2653 3.21 / 3.61 A/A 1480 28 / 22 1850 600 350 47 50 / 44 59

13.60 9.30 12.00 13.50 A 12.00 5.50 763 A 7.60 3.85 2763 2.81 / 3.41 C/B 2135 28 / 24 1850 600 350 47 51 / 46 60

14.90 10.25 13.40 15.50 3.01 / 3.41 B/B 2225 30 / 26 1850 600 350 47 53 / 48 63

10.80 7.44 9.50 10.80 A 9.50 5.50 377 A+ 7.60 4.01 2653 3.21 / 3.61 A/A 1480 28 / 22 1850 600 350 47 50 / 44 59

13.60 9.30 12.00 13.50 A 12.00 5.50 604 A 7.60 3.85 2763 2.81 / 3.41 C/B 2135 28 / 24 1850 600 350 47 51 / 46 60

14.90 10.25 13.40 15.50 3.01 / 3.41 B/B 2225 30 / 26 1850 600 350 47 53 / 48 63

RZQSG71L3V1 RZQSG100L9V1 RZQSG125L9V1 RZQSG140L9V1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1 Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High

Trade Fan Coil Price Trade Condensing Unit Price Total System Price

mm kg A A A inches m m m g/m kg dBA dBA

770 x 900 x 320 67 8.66 4 20 3/8 / 5/8 50 30 30 2.75 49 65 £999.00 £820.00 £1,819.00

990 x 940 x 320 81 1ph 12.10 17.45 4 4 32 32 3+E / 1.5 3/8 / 5/8 3/8 / 5/8 50 50 30 30 30 30 Refer to Installation Manual 2.9 2.9 53 54 69 70 £1,098.00 £1,135.00 £2,233.00

£1,211.00 £1,245.00 £2,456.00

1430 x 940 x 320 102 18.19 4 32 3/8 / 5/8 50 30 30 4.0 53 69 £1,302.00 £1,386.00 £2,688.00

990 x 940 x 320 1430 x 940 x 320 82 101 3ph 4.55 6.56 6.84 4 4 4 20 20 20 3+E / 1.5 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 50 50 50 30 30 30 30 30 30 Refer to Installation Manual 2.9 2.9 4.0 53 54 53 69 70 69 £1,098.00 £1,170.00 £2,268.00

£1,211.00 £1,282.00 £2,493.00

£1,302.00 £1,428.00 £2,730.00

Price List 2015

19


SPLIT, SKY AIR HEAT PUMPS

FLXS

Floor or Ceiling Mounted – Inverter Indoor Units Capacity

Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency

Air Flow Rate Dimensions

Weight Sound Pressure Sound Power

UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Low Height Width Depth High / Low

kW kW kW kW kW kWh kW kWh

kWh m3/min mm mm mm kg dBA dBA

Outdoor Units Dimensions Weight Electrical Details

Interconnection Wiring Piping Connections Pipework

Sound Pressure Sound Power

Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High

mm kg A A A

FLXS25B

FLXS35B9

FLXS50B

2.44 1.65 2.50 3.40 A 2.50 5.19 169 A 2.50 3.80 921 3.85 / 3.54 A/B 325 7.6 / 6 490 1050 200 16 37 / 31 51

3.34 2.14 3.50 4.00 B 3.50 4.87 252 A 2.90 3.80 1068 3.1 / 3.57 B/B 565 8.6 / 6.6 490 1050 200 16 38 / 32 53

4.82 3.16 4.90 6.10 A 4.90 5.25 326 A 4.20 3.80 1546 2.85 / 3.35 C/C 860 11.4 / 8.5 490 1050 200 17 47 / 39 60

RXS25L3

RXS35L3

RXS50L

550 x 765 x 285 34

550 x 765 x 285 34 1ph 5.10 4.3 10

735 x 825 x 300 47

3.60 3.3 10

7.60 6.8 20 3+E / 2.5 1/4 / 1/2 30 20 10

3+E / 1.5 inches m m m g/m kg dBA dBA

Trade Fan Coil Price Trade Condensing Unit Price Total System Price

1/4 / 3/8 20 15 10 1.0 46 59

1/4 / 3/8 20 15 10 20 1.2 48 61

£376.00 £476.00 £852.00

£423.00 £552.00 £975.00

Accessories:

1.7 48 62 £459.00 £694.00 £1,153.00

Notes:

Accessory Ref

Description

Trade Price

KRP413A1S KRP928A2S KLIC-DD RTD-RA UK.CWB90-2 UK.DT1 UK.CGS UK.CGM

Adaptor PCB for remote on/off control - constant/pulse contact Adaptor PCB for interface to Daikin centralised control systems KNX interface for Split type systems Adaptor PCB for Modbus connection and/or extended system functions Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm Condensing Unit Guard size 20-35 Condensing Unit Guard size 42-71

£75.00 £132.00 £164.00 £151.00 £37.00 £56.00 £214.00 £296.00

Features:

i) All fan coils supplied as standard with infrared remote controller ii) Wired controller, KLIC-DI and RTD-RA options cannot be combined iii) All fan coil units standard with auto restart after power failure iv) Minimum ambient operating temperatures: RXS

Cooling

Heating

-10°C

-15°C

> Can be installed EITHER as ceiling mounted OR wall unit > Vertical auto swing: flaps automatically swing up and down to ensure efficient air and temperature distribution in both floor level and ceiling suspended installation > Home Leave setting maintains pre-set temperature during periods of extended absence > Night set mode: prevents any sudden change in room temperature by gently raising/lowering the temperature before the system stops > Fan speed: 5 fan speeds can be selected, high to super low > Suitable for multi model applications > Re-use of existing R22 and R407C piping possible

20

Residential, Commercial and Industrial


SPLIT, SKY AIR HEAT PUMPS

FHQ-C

Ceiling Suspended – Inverter Indoor Units Capacity

Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency

Air Flow Rate Dimensions

Weight Sound Pressure Sound Power

UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Low Height Width Depth High / Low

kW kW kW kW kW kWh kW kWh

kWh m3/min mm mm mm kg dBA dBA

Outdoor Units Dimensions Weight Electrical Details

Interconnection Wiring Piping Connections Pipework

Sound Pressure Sound Power

Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High

ECA Eligible

mm kg A A A inches m m m g/m kg dBA dBA

FHQ35C

FHQ50C

FHQ60C

3.32 2.58 3.40 4.00 A++ 3.40 6.18 193 A+ 3.10 4.43 981 3.58 / 4.08 A/A 475 14 / 10 235 960 690 24 36 / 31 53

4.92 3.52 5.00 6.00 A+ 5.00 5.87 298 A 4.35 3.86 1578 3.18 / 3.35 B/C 785 15 / 10 235 960 690 25 37 / 32 54

5.57 3.93 5.70 7.20 A+ 5.70 6.02 332 A 4.71 3.87 1705 3.26 / 3.32 A/C 875 19.5 / 15 235 1270 690 31 37 / 33 54

RXS35L3

RXS50L

RXS60L

550 x 765 x 285 34

735 x 825 x 300 47 1ph 7.3 6.8 20

735 x 825 x 300 48

4.1 4.3 10 3+E / 1.5 1/4 / 3/8 20 15 10 1.2 48 61

7.8 9.4 20 3+E / 2.5

1/4 / 1/2 30 20 10 20.0 1.7 48 62

1/4 / 1/2 30 20 10

£722.00 £694.00 £1,416.00

£792.00 £740.00 £1,532.00

1.5 49 62

Trade Fan Coil Price Trade Condensing Unit Price Total System Price

£666.00 £552.00 £1,218.00

Accessories:

Notes:

Accessory Ref

Description

Trade Price

BRC7G53 EKRORO4 KRP4A53/UK.FB2 RTD-NET/UK.FB2 RTD-10/UK.FB2 RTD-20/UK.FB2 KLIC-DI KRCS01-4 K.RSS RS-SE UK.CWB90-2 UK.DT1 UK.CGS UK.CGM KDDQ50A140

Wireless remote controller Remote on/off control interface kit Unit/Group adaptor PCB for remote on/off, status indication and temperature setting Modbus Interface PCB for Sky Air and VRV Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock. Energy control PCB for Sky Air and VRV. KNX Interface for Sky Air and VRV systems Remote room mounted temperature sensor Wireless room mounted temperature sensor and receiver Service and Configuration Tool for K.RSS Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm Condensing Unit Guard size 20-35 Condensing Unit Guard size 42-71 Fresh air intake kit for up to 20% fresh air

£152.00 £29.00 £92.00 £190.00 £235.00 £251.00 £185.00 £42.00 £89.00 £93.00 £37.00 £56.00 £214.00 £296.00 £158.00

i) All fan coils supplied as standard with BRC1E52A wired remote controller with 7-day time clock ii) BRC7GA53 Trade price will be reduced by £76.00 if ordered in place of the BRC1E52A iii) All fan coil units standard with auto restart after power failure iv) Minimum ambient operating temperatures: RXS

Cooling

Heating

-10°C

-15°C

Features: > Suitable for ceiling heights of up to 3.8m without loss of capacity > Vertical auto-swing function of flaps ensures efficient air and temperature distribution > Forced off: The optional forced off feature enables the unit to switch off automatically, for example when a window is opened > Re-use of existing R22 and R407C piping possible > Suitable for Twin, Triple and Double Twin applications

Price List 2015

21


SPLIT, SKY AIR HEAT PUMPS

FHQ-C / RZQG

Ceiling Suspended – Seasonal Smart Inverter Indoor Units Capacity

Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency

Air Flow Rate Dimensions

Weight Sound Pressure Sound Power

Single Phase UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Low Height Width Depth High / Low

kW kW kW kW kW kWh kW kWh

kWh m3/min mm mm mm kg dBA dBA

Outdoor Units Dimensions Weight Electrical Details

Interconnection Wiring Piping Connections Pipework

Sound Pressure Sound Power

3 Phase

FHQ71C

FHQ100C

FHQ125C

FHQ140C

FHQ71C

FHQ100C

FHQ125C

FHQ140C

7.76 5.32 6.80 7.50 A++ 6.80 6.95 342 A+ 7.60 4.32 2462 3.82 / 4.13 A/A 890 20.5 / 14 235 1270 690 32 38 / 34 53

10.80 7.44 9.50 10.80 A++ 9.50 6.11 544 A++ 11.30 4.61 3431 4.13 / 4.42 A/A 1245 28 / 20 235 1590 690 38 42 / 34 56

13.60 9.30 12.00 13.50 A+ 12.00 6.01 698 A+ 14.13 4.23 4676 3.52 / 3.89 A/A 1790 31 / 23 235 1590 690 38 44 / 37 59

14.90 10.25 13.40 15.50 3.31 / 3.63 A/A 2025 34 / 24 235 1590 690 38 46 / 38 60

7.76 5.32 6.80 7.50 A++ 6.80 6.95 342 A+ 7.60 4.32 2462 3.82 / 4.13 A/A 890 20.5 / 14 235 1270 690 32 38 / 34 53

10.80 7.44 9.50 10.80 A++ 9.50 6.11 544 A++ 11.30 4.61 3431 4.13 / 4.42 A/A 1245 28 / 20 235 1590 690 38 42 / 34 56

13.60 9.30 12.00 13.50 A+ 12.00 6.01 698 A+ 14.13 4.23 4676 3.52 / 3.89 A/A 1790 31 / 23 235 1590 690 38 44 / 37 59

14.90 10.25 13.40 15.50 3.31 / 3.63 A/A 2025 34 / 24 235 1590 690 38 46 / 38 60

RZQG71L9V1 RZQG100L9V1 RZQG125L9V1 RZQG140L9V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1 Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High

mm kg A A A inches m m m g/m kg dBA dBA

ECA Eligible Trade Fan Coil Price Trade Condensing Unit Price Total System Price

990 x 940 x 320 78 7.27 4 20 3/8 / 5/8 50 30 30 2.9 48 64

1430 x 940 x 320 102 1ph 10.18 14.63 4 4 32 32 3+E / 1.5 3/8 / 5/8 3/8 / 5/8 75 75 30 30 30 30 Refer to Installation Manual 4.0 4.0 50 51 66 67

£926.00 £1,191.00 £2,117.00

£983.00 £1,514.00 £2,497.00

£1,229.00 £1,666.00 £2,895.00

990 x 940 x 320 80 16.55 4 32

2.74 4 16

3/8 / 5/8 75 30 30

3/8 / 5/8 50 30 30

4.0 52 69

2.9 48 64

£1,459.00 £1,901.00 £3,360.00

1430 x 940 x 320 101 3ph 3.83 5.50 4 4 20 20 3+E / 1.5 3/8 / 5/8 3/8 / 5/8 75 75 30 30 30 30 Refer to Installation Manual 4.0 4.0 50 51 66 67

£926.00 £1,227.00 £2,153.00

£983.00 £1,584.00 £2,567.00

£1,229.00 £1,743.00 £2,972.00

Accessories:

3/8 / 5/8 75 30 30 4.0 52 69

£1,459.00 £2,002.00 £3,461.00

Notes:

Accessory Ref

Description

Trade Price

BRC7G53 EKRORO4 KRP4A53/UK.FB2 RTD-NET/UK.FB2 RTD-10/UK.FB2 RTD-20/UK.FB2 KLIC-DI KRCS01-4 K.RSS RS-SE UK.CWB90-2 UK.CWB140-2 UK.DT2 UK.CGS UK.CGM UK.CGL KDDQ50A140

Wireless remote controller Remote on/off control interface kit Unit/Group adaptor PCB for remote on/off, status indication and temperature setting Modbus Interface PCB for Sky Air and VRV Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock Energy control PCB for Sky Air and VRV KNX Interface for Sky Air and VRV systems Remote room mounted temperature sensor Wireless room mounted temperature sensor and receiver Service and Configuration Tool for K.RSS Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU Condensate drip tray for use with Sky Air ODU - tray width 1100mm Condensing Unit Guard size 20-35 Condensing Unit Guard size 42-71 Condensing Unit Guard size 100-140 including RXYSQ Fresh air intake kit for up to 20% fresh air

£152.00 £29.00 £92.00 £190.00 £235.00 £251.00 £185.00 £42.00 £89.00 £93.00 £37.00 £46.00 £59.00 £214.00 £296.00 £354.00 £158.00

i) All fan coils supplied as standard with BRC1E52A wired remote controller with 7-day time clock ii) BRC7GA53 Trade price will be reduced by £76.00 if ordered in place of the BRC1E52A iii) All fan coil units standard with auto restart after power failure iv) Minimum ambient operating temperatures: RZQG RZQSG

Features: > Suitable for ceiling heights of up to 3.8m without loss of capacity > Seasonally Efficient Inverter Technology gives up to 25% better efficiency than inverter technology > Forced off: The optional forced off enables the unit to switch off automatically, for example when a window is opened > Re-use of existing R22 and R407C piping possible

22

6.23 4 20

Residential, Commercial and Industrial

> Suitable for Twin, Triple and Double Twin applications > Comms, computer and server room cooling possible with EDP setting (Seasonal Smart) > Selectable evaporating & condensing temperature for greater operating efficiency (Seasonal Smart) > DIII net compatibility as standard

Cooling

Heating

-15°C -15°C

-20°C -15°C


SPLIT, SKY AIR HEAT PUMPS

FHQ-C / RZQSG

Ceiling Suspended – Seasonal Classic Inverter Indoor Units Capacity

Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency

Air Flow Rate Dimensions

Weight Sound Pressure Sound Power

Single Phase UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Low Height Width Depth High / Low

kW kW kW kW kW kWh kW kWh

kWh m3/min mm mm mm kg dBA dBA

Outdoor Units Dimensions Weight Electrical Details

Interconnection Wiring Piping Connections Pipework

Sound Pressure Sound Power

3 Phase

FHQ71C

FHQ100C

FHQ125C

FHQ140C

FHQ100C

FHQ125C

FHQ140C

7.28 4.99 6.80 7.50 A+ 6.80 5.61 424 A 7.60 3.90 2727 3.46 / 4 A/A 983 20.5 / 14 235 1270 690 32 38 / 34 53

10.80 7.44 9.50 10.80 A+ 9.50 5.61 592 A 7.60 3.91 2721 3.21 / 3.61 A/A 1480 28 / 20 235 1590 690 38 42 / 34 56

13.60 9.30 12.00 13.50 A+ 12.00 5.61 748 A+ 7.60 4.01 2653 2.89 / 3.62 C/A 2075 31 / 23 235 1590 690 38 44 / 37 59

14.90 10.25 13.40 15.50 3.01 / 3.41 B/B 2225 34 / 24 235 1590 690 38 46 / 38 60

10.80 7.44 9.50 10.80 A+ 9.50 5.61 592 A 7.60 3.91 2721 3.21 / 3.61 A/A 1480 28 / 20 235 1590 690 38 42 / 34 56

13.60 9.30 12.00 13.50 A+ 12.00 5.61 748 A+ 7.60 4.01 2653 2.89 / 3.62 C/A 2075 31 / 23 235 1590 690 38 44 / 37 59

14.90 10.25 13.40 15.50 3.01 / 3.41 B/B 2225 34 / 24 235 1590 690 38 46 / 38 60

RZQSG71L3V1 RZQSG100L9V1 RZQSG125L9V1 RZQSG140L9V1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1 Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High

Trade Fan Coil Price Trade Condensing Unit Price Total System Price

mm kg A A A inches m m m g/m kg dBA dBA

770 x 900 x 320 67 8.05 4 20 3/8 / 5/8 50 30 30 2.75 49 65 £926.00 £820.00 £1,746.00

990 x 940 x 320 81 1ph 12.10 16.96 4 4 32 32 3+E / 1.5 3/8 / 5/8 3/8 / 5/8 50 50 30 30 30 30 Refer to Installation Manual 2.9 2.9 53 54 69 70 £983.00 £1,135.00 £2,118.00

£1,229.00 £1,245.00 £2,474.00

1430 x 940 x 320 102 18.19 4 32 3/8 / 5/8 50 30 30 4.0 53 69 £1,459.00 £1,386.00 £2,845.00

990 x 940 x 320 1430 x 940 x 320 82 101 3ph 4.52 6.34 6.80 4 4 4 20 20 20 3+E / 1.5 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 50 50 50 30 30 30 30 30 30 Refer to Installation Manual 2.9 2.9 4.0 53 54 53 69 70 69 £983.00 £1,170.00 £2,153.00

£1,229.00 £1,282.00 £2,511.00

£1,459.00 £1,428.00 £2,887.00

Price List 2015

23


SPLIT, SKY AIR HEAT PUMPS

FUQ-C / RZQG

Under Ceiling Cassette – Seasonal Smart Inverter Indoor Units Capacity

Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency

Air Flow Rate Dimensions

Weight Sound Pressure Sound Power

Single Phase UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Low Height Width Depth High / Low

kW kW kW kW kW kWh kW kWh

kWh m3/min mm mm mm kg dBA dBA

Outdoor Units Dimensions Weight Electrical Details

Interconnection Wiring Piping Connections Pipework

Sound Pressure Sound Power

Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High

mm kg A A A inches m m m g/m kg dBA dBA

ECA Eligible Trade Fan Coil Price Trade Condensing Unit Price Total System Price

3 Phase

FUQ71C

FUQ100C

FUQ125C

FUQ71C

FUQ100C

FUQ125C

7.76 5.32 6.80 7.50 A++ 6.80 6.50 366 A+ 7.60 4.20 2533 4.07 / 4.47 A/A 840 23 / 16 198 950 950 25 41 / 35 59

10.80 7.44 9.50 10.80 A++ 9.50 6.11 544 A+ 11.30 4.50 3517 4.08 / 4.04 A/A 1230 31 / 20 198 950 950 26 46 / 39 64

13.60 9.30 12.00 13.50 A+ 12.00 5.61 748 A+ 14.13 4.44 4456 3.4 / 4.04 A/A 1770 32.5 / 20.5 198 950 950 26 47 / 40 65

7.76 5.32 6.80 7.50 A++ 6.80 6.50 366 A+ 7.60 4.20 2533 4.07 / 4.47 A/A 840 23 / 16 198 950 950 25 41 / 35 59

10.80 7.44 9.50 10.80 A++ 9.50 6.11 544 A+ 11.30 4.50 3515 4.08 / 4.04 A/A 1230 31 / 20 198 950 950 26 46 / 39 64

13.60 9.30 12.00 13.50 A+ 12.00 5.61 748 A+ 14.13 4.44 4456 3.4 / 4.04 A/A 1770 32.5 / 20.5 198 950 950 26 47 / 40 65

RZQG71L9V1

RZQG100L9V1

RZQG125L9V1

RZQG71L8Y1

RZQG100L8Y1

RZQG125L8Y1

990 x 940 x 320 78

1430 x 940 x 320 102

2.9 48 64

1ph 9.52 4 32 3+E / 1.5 3/8 / 5/8 75 30 30 Refer to Installation Manual 4.0 50 66

£857.00 £1,191.00 £2,048.00

£940.00 £1,514.00 £2,454.00

6.83 4 20 3/8 / 5/8 50 30 30

990 x 940 x 320 80

14.06 4 32

2.57 4 16

3/8 / 5/8 75 30 30

3/8 / 5/8 50 30 30

4.0 51 67

2.9 48 64

3ph 3.58 4 20 3+E / 1.5 3/8 / 5/8 75 30 30 Refer to Installation Manual 4.0 50 66

£857.00 £1,227.00 £2,084.00

£940.00 £1,584.00 £2,524.00

£1,037.00 £1,666.00 £2,703.00

Accessories:

5.29 4 20 3/8 / 5/8 75 30 30 4.0 51 67

£1,037.00 £1,743.00 £2,780.00

Notes:

Accessory Ref

Description

Trade Price

BRC7C58 EKRORO5 KRP4A53/UK.FB2 RTD-NET/UK.FB2 RTD-10/UK.FB2 RTD-20/UK.FB2 KLIC-DI KRCS01-4 K.RSS RS-SE UK.CWB90-2 UK.CWB140-2 UK.DT2 UK.CGM UK.CGL

Wireless remote controller Remote on/off control interface kit Unit/Group adaptor PCB for remote on/off, status indication and temperature setting Modbus Interface PCB for Sky Air and VRV Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock Energy control PCB for Sky Air and VRV KNX Interface for Sky Air and VRV systems Remote room mounted temperature sensor Wireless room mounted temperature sensor and receiver Service and Configuration Tool for K.RSS Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU Condensate drip tray for use with Sky Air ODU - tray width 1100mm Condensing Unit Guard size 42-71 Condensing Unit Guard size 100-140 including RXYSQ

£152.00 £29.00 £92.00 £190.00 £235.00 £251.00 £185.00 £42.00 £89.00 £93.00 £37.00 £46.00 £59.00 £296.00 £354.00

Features: > The 4-way blow under ceiling cassettes are the ideal solution for rooms, shops or offices without false ceilings > Seasonally Efficient Inverter Technology gives up to 25% better efficiency than inverter technology > Air flow flexibility: air can be discharged in any of 4 directions. Possibility to shut off 1 or 2 flaps enabling the unit to be installed in a corner or small room > 3 step fan-speed > Suitable for Twin, Triple and Double Twin applications > Re-use of existing R22 and R407C piping possible > Comms, computer and server room cooling possible with EDP setting > Selectable evaporating & condensing temperature for greater operating efficiency

24

1430 x 940 x 320 101

Residential, Commercial and Industrial

i) All fan coils supplied as standard with BRC1E52A wired remote controller with 7-day time clock ii) BRC7C58 Trade price will be reduced by £76.00 if ordered in place of the BRC1E52A iii) All fan coil units standard with auto restart after power failure iv) Minimum ambient operating temperatures: RZQG

Cooling

Heating

-15°C

-20°C


SPLIT, SKY AIR HEAT PUMPS

FCQHG / RZQG

High COP Roundflow Cassette – Seasonal Smart Inverter Indoor Units Capacity

UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Seasonal Efficiency Energy Label (EN14825) Pdesign COOLING SEER Annual Energy Consumption Seasonal Efficiency Energy Label (EN14825) Pdesign HEATING SCOP Annual Energy Consumption Nominal Efficiency EER / COP Energy Label Annual Energy Consumption Air Flow Rate High / Low Dimensions Height (with Decoration Panel) Width Depth Weight (with Decoration Panel) Sound Pressure High / Low Sound Power Outdoor Units Dimensions Weight Electrical Details

Interconnection Wiring Piping Connections Pipework

Sound Pressure Sound Power

Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High

ECA Eligible Trade Fan Coil Price Trade Condensing Unit Price Total System Price

kW kW kW kW kW kWh kW kWh

kWh m3/min mm mm mm kg dBA dBA mm kg A A A inches m m m g/m kg dBA dBA

FCQHG71F 7.76 5.32 6.80 7.50 A++ 6.80 7.00 340 A+ 7.60 4.54 2343 4.09 / 4.8 A/A 830 21.2 / 12.2 288(348) 840 (950) 840 (950) 25 (30.4) 36 / 29 53

Single Phase FCQHG100F FCQHG125F 10.80 13.60 7.44 9.30 9.50 12.00 10.80 13.50 A++ A++ 9.50 12.00 7.00 6.61 475 635 A++ A++ 11.30 12.66 4.80 4.63 3295 3829 4.42 / 4.99 4 / 4.4 A/A A/A 1075 1500 32.3 / 19 33.5 / 19.9 288 (348) 288 (348) 840 (950) 840 (950) 840 (950) 840 (950) 26 (31.4) 26 (31.4) 44 / 33 45 / 35 61 61

FCQHG140F 14.90 10.25 13.40 15.50 3.35 / 4.12 A/A 2000 33.5 / 21.1 288 (348) 840 (950) 840 (950) 26 (31.4) 45 / 37 61

FCQHG71F 7.76 5.32 6.80 7.50 A++ 6.80 7.00 340 A+ 7.60 4.54 2343 4.09 / 4.8 A/A 830 21.2 / 12.2 288(348) 840 (950) 840 (950) 25 (30.4) 36 / 29 53

FCQHG140F 14.90 10.25 13.40 15.50 3.35 / 4.14 A/A 2000 33.5 / 21.1 288 (348) 840 (950) 840 (950) 26 (31.4) 45 / 37 61

RZQG71L9V1 RZQG100L9V1 RZQG125L9V1 RZQG140L9V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320 78 102 80 101 1ph 3ph 6.78 8.79 12.26 16.35 2.55 3.31 4.61 6.15 4 4 4 4 4 4 4 4 20 32 32 32 16 20 20 20 3+E / 1.5 3+E / 1.5 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 50 75 75 75 50 75 75 75 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 Refer to Installation Manual Refer to Installation Manual 2.9 4.0 4.0 4.0 2.9 4.0 4.0 4.0 48 50 51 52 48 50 51 52 64 66 67 69 64 66 67 69 ●

£787.00 £1,191.00 £1,978.00

£890.00 £1,514.00 £2,404.00

£972.00 £1,666.00 £2,638.00

£1,168.00 £1,901.00 £3,069.00

£787.00 £1,227.00 £2,014.00

£890.00 £1,584.00 £2,474.00

£972.00 £1,743.00 £2,715.00

£1,168.00 £2,002.00 £3,170.00

Accessories:

Notes:

Accessory Ref

Description

Trade Price

BRC7FA532F BYCQ140DG BYCQ140DW BRYQ140A KDBHQ55B140 KDDQ55B140 1&2 KRP4A53/UK.FB2 RTD-NET/UK.FB2 RTD-10/UK.FB2 RTD-20/UK.FB2 KLIC-DI KRCS01-4 K.RSS RS-SE UK.CWB90-2 UK.CWB140-2 UK.DT2 UK.CGM UK.CGL

Wireless remote controller Roundflow cassette decoration panel with self cleaning filter Roundflow cassette decoration panel - white with white louvres Integral PIR Sensor for Roundflow decoration panel. Enables Energy Saving functions Sealing member for air discharge outlet Fresh air intake kit for up to 20% fresh air - 2 part kit Unit/Group adaptor PCB for remote on/off, status indication and temperature setting Modbus Interface PCB for Sky Air and VRV Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock Energy control PCB for Sky Air and VRV KNX Interface for Sky Air and VRV systems Remote room mounted temperature sensor Wireless room mounted temperature sensor and receiver Service and Configuration Tool for K.RSS Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU Condensate drip tray for use with Sky Air ODU - tray width 1100mm Condensing Unit Guard size 42-71 Condensing Unit Guard size 100-140 including RXYSQ

£152.00 £310.00 £160.00 £99.00 £90.00 £233.00 £92.00 £190.00 £235.00 £251.00 £185.00 £42.00 £89.00 £93.00 £37.00 £46.00 £59.00 £296.00 £354.00

Features:

3 Phase FCQHG100F FCQHG125F 10.80 13.60 7.44 9.30 9.50 12.00 10.80 13.50 A++ A++ 9.50 12.00 7.00 6.61 475 635 A++ A++ 11.30 12.66 4.80 4.63 3295 3829 4.42 / 4.99 4 / 4.4 A/A A/A 1075 1500 32.3 / 19 33.5 / 19.9 288 (348) 288 (348) 840 (950) 840 (950) 840 (950) 840 (950) 26 (31.4) 26 (31.4) 44 / 33 45 / 35 61 61

i) All fan coils supplied as standard with BRC1E52A wired remote controller with 7-day time clock ii) BRC7FA532F Trade price will be reduced by £76.00 if ordered in place of the BRC1E52A iii) All fan coil units standard with auto restart after power failure iv) All fan coils suppled as standard with BYCQ140D Decoration panel v) BYCQ140DW / BYCQ140DG Trade prices will be reduced by £142.00 if ordered in place of standard decoration panel vi) Minimum ambient operating temperatures:

RZQG RZQSG AZQS

Cooling

Heating

-15°C -15°C -5°C

-20°C -15°C -15°C

vii) FCQG-F / FCQHG-F compatible with RZQG / RZQSG

> The FCQHG model is designed for 2014 ErP regulations and has one of the highest COP values on the market viii) FCQG-F / FCQHG-F are same price > The unique 360° radial air pattern ensures uniform air flow and temperature distribution > Air flow flexibility: a wide selection of 23 different air flow patterns accessible via remote controller > Optional Presence Sensors detects if room is unoccupied and allows temperature to drift to set-back levels > Optional Self Cleaning Filter The BYCQ140DG decoration panel can offer energy savings, reduced maintenance time and cost > Optional Fresh Air intake (up to 20%) possible > Suitable for Twin, Triple and Double Twin applications (Smart & Classic) > Re-use of existing R22 and R407C piping possible > Comms, computer and server room cooling possible with EDP setting (Seasonal Smart) > Selectable evaporating & condensing temperature for greater operating efficiency (Seasonal Smart) > DIII net compatibility as standard

Price List 2015

25


SPLIT, SKY AIR HEAT PUMPS

FCQG / RZQSG

Compact Roundflow Cassette – Seasonal Classic Inverter Indoor Units

Single Phase

Capacity

UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Seasonal Efficiency Energy Label (EN14825) Pdesign COOLING SEER Annual Energy Consumption Seasonal Efficiency Energy Label (EN14825) Pdesign HEATING SCOP Annual Energy Consumption Nominal Efficiency EER / COP Energy Label Annual Energy Consumption Air Flow Rate High / Low Dimensions Height (with Decoration Panel) Width Depth Weight (with Decoration Panel) Sound Pressure High / Low Sound Power Outdoor Units Dimensions Weight Electrical Details

Interconnection Wiring Piping Connections Pipework

Sound Pressure Sound Power

Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High

kW kW kW kW kW kWh kW kWh

kWh m3/min mm mm mm kg dBA dBA mm kg A A A inches m m m g/m kg dBA dBA

ECA Eligible Trade Fan Coil Price Trade Condensing Unit Price Total System Price

3 Phase

FCQG71F

FCQG100F

FCQG125F

FCQG140F

FCQG100F

FCQG125F

FCQG140F

7.28 4.99 6.80 7.50 A++ 6.80 6.10 390 A+ 6.33 4.10 2162 3.21 / 3.61 A/A 971 15 / 9.1 204 (264) 840 (950) 840 (950) 21 (26.4) 33 / 28 51

10.80 7.44 9.50 10.80 A++ 9.50 6.50 511 A+ 7.60 4.10 2595 3.3 / 3.54 A/B 1440 22.8 / 12.4 246 (306) 840 (950) 840 (950) 24 (29.4) 37 / 29 54

13.60 9.30 12.00 13.50 A 12.00 5.30 792 A+ 8.03 4.01 2803 3.21 / 3.41 A/B 1870 26 / 12.4 246 (306) 840 (950) 840 (950) 24 (29.4) 41 / 29 58

14.90 10.25 13.40 15.50 3.01 / 3.41 B/B 2225 26 / 12.4 246 (306) 840 (950) 840 (950) 24 (29.4) 41 / 29 58

10.80 7.44 9.50 10.80 A++ 9.50 6.50 511 A+ 7.60 4.10 2595 3.3 / 3.54 A/B 1440 22.8 / 12.4 246 (306) 840 (950) 840 (950) 24 (29.4) 37 / 29 54

13.60 9.30 12.00 13.50 A 12.00 5.30 792 A+ 8.03 4.01 2803 3.21 / 3.41 A/B 1870 26 / 12.4 246 (306) 840 (950) 840 (950) 24 (29.4) 41 / 29 58

14.90 10.25 13.40 15.50 3.01 / 3.41 B/B 2225 26 / 12.4 246 (306) 840 (950) 840 (950) 24 (29.4) 41 / 29 58

RZQSG71L3V1 RZQSG100L9V1 RZQSG125L9V1 RZQSG140L9V1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1 770 x 900 x 320 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320 67 81 102 82 101 1ph 3ph 8.66 11.77 15.29 18.19 4.40 5.72 6.80 4 4 4 4 4 4 4 20 32 32 32 20 20 20 3+E / 1.5 3+E / 1.5 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 50 50 50 50 50 50 50 30 30 30 30 30 30 30 30 30 30 30 30 30 30 Refer to Installation Manual Refer to Installation Manual 2.75 2.9 2.9 4.0 2.9 2.9 4.0 49 53 54 53 53 54 53 65 69 70 69 69 70 69 ●

£787.00 £820.00 £1,607.00

£890.00 £1,135.00 £2,025.00

£972.00 £1,245.00 £2,217.00

£1,168.00 £1,386.00 £2,554.00

Accessories:

£890.00 £1,170.00 £2,060.00

£972.00 £1,282.00 £2,254.00

£1,168.00 £1,428.00 £2,596.00

Notes:

Accessory Ref

Description

Trade Price

BRC7FA532F BYCQ140DG BYCQ140DW BRYQ140A KDBHQ55B140 KDDQ55B140 1&2 KRP4A53/UK.FB2 RTD-NET/UK.FB2 RTD-10/UK.FB2 RTD-20/UK.FB2 KLIC-DI KRCS01-4 K.RSS RS-SE UK.CWB90-2 UK.CWB140-2 UK.DT2 UK.CGM UK.CGL

Wireless remote controller Roundflow cassette decoration panel with self cleaning filter Roundflow cassette decoration panel - white with white louvres Integral PIR Sensor for Roundflow decoration panel. Enables Energy Saving functions Sealing member for air discharge outlet Fresh air intake kit for up to 20% fresh air - 2 part kit Unit/Group adaptor PCB for remote on/off, status indication and temperature setting Modbus Interface PCB for Sky Air and VRV Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock Energy control PCB for Sky Air and VRV KNX Interface for Sky Air and VRV systems Remote room mounted temperature sensor Wireless room mounted temperature sensor and receiver Service and Configuration Tool for K.RSS Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU Condensate drip tray for use with Sky Air ODU - tray width 1100mm Condensing Unit Guard size 42-71 Condensing Unit Guard size 100-140 including RXYSQ

£152.00 £310.00 £160.00 £99.00 £90.00 £233.00 £92.00 £190.00 £235.00 £251.00 £185.00 £42.00 £89.00 £93.00 £37.00 £46.00 £59.00 £296.00 £354.00

Features:

i) All fan coils supplied as standard with BRC1E52A wired remote controller with 7-day time clock ii) BRC7FA532F Trade price will be reduced by £76.00 if ordered in place of the BRC1E52A iii) All fan coil units standard with auto restart after power failure iv) All fan coils suppled as standard with BYCQ140D Decoration panel v) BYCQ140DW / BYCQ140DG Trade prices will be reduced by £142.00 if ordered in place of standard decoration panel vi) Minimum ambient operating temperatures:

RZQG RZQSG AZQS

Cooling

Heating

-15°C -15°C -5°C

-20°C -15°C -15°C

vii) FCQG-F / FCQHG-F compatible with RZQG / RZQSG

> FCQG is the slimmer cassette on the market, able to fit in narrower ceilings viii) FCQG-F / FCQHG-F are same price > The unique 360° radial air pattern ensures uniform air flow and temperature distribution > Air flow flexibility: a wide selection of 23 different air flow patterns accessible via remote controller > Optional Presence Sensors detects if room is unoccupied and allows temperature to drift to set-back levels > Optional Self Cleaning Filter The BYCQ140DG decoration panel can offer energy savings, reduced maintenance time and cost > Optional Fresh Air intake (up to 20%) possible > Suitable for Twin, Triple and Double Twin applications (Classic) > Re-use of existing R22 and R407C piping possible (Classic & Inverter) > DIII net compatibility as standard

26

Residential, Commercial and Industrial


SPLIT, SKY AIR HEAT PUMPS

FCQG-F / AZQS

Compact Roundflow Cassette – Seasonal Inverter Indoor Units

Single Phase

Capacity

UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Seasonal Efficiency Energy Label (EN14825) Pdesign COOLING SEER Annual Energy Consumption Seasonal Efficiency Energy Label (EN14825) Pdesign HEATING SCOP Annual Energy Consumption Nominal Efficiency EER / COP Energy Label Annual Energy Consumption Air Flow Rate High / Low Dimensions Height (with Decoration Panel) Width Depth Weight (with Decoration Panel) Sound Pressure High / Low Sound Power

kW kW kW kW kW kWh kW kWh

kWh m3/min mm mm mm kg dBA dBA

Outdoor Units Dimensions Weight Electrical Details

Interconnection Wiring Piping Connections Pipework

Sound Pressure Sound Power

Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High

mm kg

FCQG100F

FCQG125F

FCQG140F

FCQG100F

FCQG125F

FCQG140F

7.28 4.99 6.80 7.50 A+ 6.80 5.70 TBC A 7.50 4.00 TBC B/A 3.11 / 3.61 TBC 15 / 9.1 204 (264) 840 (950) 840 (950) 21 (26.4) 33 / 28 51

10.80 7.44 9.50 10.80 A 9.50 5.50 TBC A 10.80 3.85 TBC A/B 3.21 / 3.50 TBC 22.8 / 12.4 246 (306) 840 (950) 840 (950) 24 (29.4) 37 / 29 54

13.60 9.30 12.10 13.50 B/B 3.10 / 3.41 TBC 26 / 12.4 246 (306) 840 (950) 840 (950) 24 (29.4) 41 / 29 58

14.90 10.25 13.40 15.50 C/B 2.81 / 3.30 TBC 26 / 12.4 246 (306) 840 (950) 840 (950) 24 (29.4) 41 / 29 58

10.80 7.44 9.50 10.80 A 9.50 5.50 TBC A 10.80 3.85 TBC A/B 3.21 / 3.50 TBC 22.8 / 12.4 246 (306) 840 (950) 840 (950) 24 (29.4) 37 / 29 54

13.60 9.30 12.10 13.50 B/B 3.10 / 3.41 TBC 26 / 12.4 246 (306) 840 (950) 840 (950) 24 (29.4) 41 / 29 58

14.90 10.25 13.40 15.50 C/B 2.81 / 3.30 TBC 26 / 12.4 246 (306) 840 (950) 840 (950) 24 (29.4) 41 / 29 58

AZQS71BV1

AZQS100B8V1

AZQS125B8V1

AZQS140B8V1

AZQS100BY1

AZQS125BY1

AZQS140BY1

770 x 900 x 320 67

A A A

8.66* 4 20

inches m m m g/m kg dBA dBA

3/8 / 5/8 30 15 30 2.75 49 65

Trade Fan Coil Price Trade Condensing Unit Price Total System Price

3 Phase

FCQG71F

£787.00 £714.00 £1,501.00

990 x 940 x 320 81 1ph 11.77* 15.29* 4 4 32 32 3+E / 1.5 3/8 / 5/8 3/8 / 5/8 30 30 15 15 30 30 Refer to Installation Manual 2.9 2.9 53 54 69 70 £890.00 £878.00 £1,768.00

1430 x 940 x 320 102

£972.00 £986.00 £1,958.00

18.19* 4 32 3/8 / 5/8 30 15 30 4.0 53 69 £1,168.00 £1,104.00 £2,272.00

990 x 940 x 320 1430 x 940 x 320 82 101 3ph 4.40* 5.72* 6.80* 4 4 4 20 20 20 3+E / 1.5 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 30 30 30 15 15 15 30 30 30 Refer to Installation Manual 2.9 2.9 4.0 53 54 53 69 70 69 £890.00 £926.00 £1,816.00

£972.00 £1,038.00 £2,010.00

£1,168.00 £1,164.00 £2,332.00

* Provisional data

One cassette, 3 options: Daikin’s Roundflow Cassette range has a solution for all your needs: > Price > Performance > Highest Efficiency

> > > > >

Pair applications 30m pipe run -5 / -15°C operating range in cooling / heating A/A Energy Labels R22 replace technology

FCQG-F Series cassette BYFQ140D Roundflow decoration panel BRC1E52 remote control

> > > > >

Pair, twin, triple, double twin applications 50m pipe run -15 / -15°C operating range in cooling / heating A+/A+ Energy Labels R22 replace technology

> > > > > >

Pair, twin, triple, double twin applications 75m pipe run -15 / -20°C operating range in cooling / heating Up to A++/A+ Energy Labels All capacities ECA Eligible R22 replace technology

Price List 2015

27


SPLIT, SKY AIR HEAT PUMPS

FCQG / RXS

Compact Roundflow Cassette – Inverter Indoor Units Capacity

UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Seasonal Efficiency Energy Label (EN14825) Pdesign COOLING SEER Annual Energy Consumption Seasonal Efficiency Energy Label (EN14825) Pdesign HEATING SCOP Annual Energy Consumption Nominal Efficiency EER / COP Energy Label Annual Energy Consumption Air Flow Rate High / Low Dimensions Height (with Decoration Panel) Width Depth Weight (with Decoration Panel) Sound Pressure High / Low Sound Power Outdoor Units Dimensions Weight Electrical Details

Interconnection Wiring Piping Connections Pipework

Sound Pressure Sound Power

Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High

kW kW kW kW kW kWh kW kWh

kWh m3/min mm mm mm kg dBA dBA

mm kg A A A inches m m m g/m kg dBA dBA

ECA Eligible Trade Fan Coil Price Trade Condensing Unit Price Total System Price

FCQG35F

FCQG50F

FCQG60F

3.32 2.29 3.40 4.20 A++ 3.50 6.35 193 A++ 3.32 4.90 949 3.58 / 3.5 A/B 475 12.5 / 8.7 204 (264) 840 (950) 840 (950) 18 (23.4) 31 / 27 49

4.89 3.26 5.00 6.00 A++ 5.00 6.48 270 A++ 4.36 4.29 1426 3.55 / 3.7 A/A 705 12.6 / 8.7 204 (264) 840 (950) 840 (950) 19 (24.4) 31 / 27 49

5.57 3.67 5.70 7.00 A++ 5.70 6.22 321 A+ 4.71 4.00 1646 3.48 / 3.52 A/B 820 13.6 / 8.7 204 (264) 840 (950) 840 (950) 19 (24.4) 33 / 28 51

RXS35L3 550 x 765 x 285 34

RXS50L 735 x 825 x 300 47 1ph 6.30 6.80 20

RXS60L 735 x 825 x 300 48

4.00 4.30 10 3+E / 1.5 1/4 / 3/8 20 15 10 20 1.2 48 61

7.40 9.40 20 3+E / 2.5

1/4 / 1/2 30 20 10 20 1.7 48 62

£683.00 £552.00 £1,235.00

£699.00 £694.00 £1,393.00

Accessories:

1/4 / 1/2 30 20 10 20 1.5 49 62

£743.00 £740.00 £1,483.00

Notes:

Accessory Ref

Description

Trade Price

BRC7FA532F BYCQ140DG BYCQ140DW BRYQ140A KDBHQ55B140 KDDQ55B140 1&2 KRP4A53/UK.FB2 RTD-NET/UK.FB2 RTD-10/UK.FB2 RTD-20/UK.FB2 KLIC-DI KRCS01-4 K.RSS RS-SE UK.CWB90-2 UK.DT1 UK.CGM

Wireless remote controller Roundflow cassette decoration panel with self cleaning filter Roundflow cassette decoration panel - white with white louvres Integral PIR Sensor for Roundflow decoration panel. Enables Energy Saving functions Sealing member for air discharge outlet Fresh air intake kit for up to 20% fresh air - 2 part kit Unit/Group adaptor PCB for remote on/off, status indication and temperature setting Modbus Interface PCB for Sky Air and VRV Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock Energy control PCB for Sky Air and VRV KNX Interface for Sky Air and VRV systems Remote room mounted temperature sensor Wireless room mounted temperature sensor and receiver Service and Configuration Tool for K.RSS Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm Condensing Unit Guard size 42-71

£152.00 £310.00 £160.00 £99.00 £90.00 £233.00 £92.00 £190.00 £235.00 £251.00 £185.00 £42.00 £89.00 £93.00 £37.00 £56.00 £296.00

i) All fan coils supplied as standard with BRC1E52A wired remote controller with 7-day time clock ii) BRC7FA532F Trade price will be reduced by £76.00 if ordered in place of the BRC1E52A iii) All fan coil units standard with auto restart after power failure iv) All fan coils suppled as standard with BYCQ140D Decoration panel v) BYCQ140DW / BYCQ140DG Trade prices will be reduced by £142.00 if ordered in place of standard decoration panel vi) Minimum ambient operating temperatures: RXS

Features: > FCQG is a compact cassette designed to suit installation in narrower ceiling voids > The unique 360° radial air pattern ensures uniform air flow and temperature distribution > Air flow flexibility: a wide selection of 23 different air flow patterns accessible via remote controller > Optional Presence Sensors detects if room is unoccupied and allows temperature to drift to set-back levels > Optional Self Cleaning Filter: The BYCQ140DG decoration panel can offer energy savings, reduced maintenance time and cost > Suitable for Twin, Triple and Double Twin applications > Re-use of existing R22 and R407C piping possible > DIII net compatibility as standard

28

Residential, Commercial and Industrial

Cooling

Heating

-10°C

-15°C


SPLIT, SKY AIR HEAT PUMPS

FFQ / RXS

600x600 Fully Flat Cassette Indoor Units Capacity

UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Seasonal Efficiency (EN14825) Pdesign COOLING SEER Annual Energy Consumption Energy Label Seasonal Efficiency (EN14825) Pdesign HEATING SCOP Annual Energy Consumption Nominal Efficiency EER / COP Energy Label Annual Energy Consumption Air Flow Rate High / Low Dimensions Height (with Decoration Panel) Width Depth Weight (with Decoration Panel) Sound Pressure High / Low Sound Power

kW kW kW kW kW kWh kW kWh

kWh m3/min mm mm mm kg dBA dBA

Outdoor Units Dimensions Weight Electrical Details

Interconnection Wiring Piping Connections Pipework

Sound Pressure Sound Power

Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High

ECA Eligible Trade Fan Coil Price Trade Condensing Unit Price Total System Price

mm kg

FFQ25C

FFQ35C

FFQ50C

FFQ60C

2.44 1.81 2.50 3.20 A++ 2.50 6.11 143 A+ 2.31 4.24 763 4.46 / 3.9 A/A 280 9 / 6.5 260 (306) 575 (620) 575 (620) 17.5 (20.2) 31 / 25 48

3.32 2.28 3.40 4.00 A++ 3.40 6.32 188 A+ 3.10 4.10 1059 3.7 / 3.5 A/B 460 10 / 6.5 260 (306) 575 (620) 575 (620) 17.5 (20.2) 34 / 25 51

4.62 3.40 4.70 5.50 A+ 5.00 5.93 295 A 3.84 3.90 1378 3.21 / 3.49 A/B 780 12 / 7.5 260 (306) 575 (620) 575 (620) 17.5 (20.2) 39 / 27 56

5.72 4.20 5.80 7.00 A+ 5.80 5.71 349 A+ 3.96 4.04 1373 3.02 / 3.41 B/B 945 14.5 / 9.5 260 (306) 575 (620) 575 (620) 17.5 (20.2) 43 / 32 60

RXS25L3

RXS35L3

RXS50L

RXS60L

550 x 765 x 285 34

550 x 765 x 285 34

735 x 825 x 300 47

735 x 825 x 300 48

4.00 3.3 10

4.00 4.3 10

6.90 6.8 20

8.30 9.4 20

1/4 / 3/8 20 15 10

1/4 / 3/8 20 15 10

1/4 / 1/2 30 20 10

1/4 / 1/2 30 20 10

1.0 46 61

1.2 48 61

1.7 48 62

1.5 49 62

£766.00 £694.00 £1,460.00

£809.00 £740.00 £1,549.00

1ph A A A

3+E / 1.5 inches m m m g/m kg dBA dBA

3+E / 2.5

20

£636.00 £476.00 £1,112.00

£696.00 £552.00 £1,248.00

Accessories:

Notes:

Accessory Ref

Description

Trade Price

BYFQ60CW BYFQ60CS BYFQ60B3 BRYQ60AW BRYQ60AS BRC7F530W BRC7F530S BRC7EB530W BDBHQ44C60 KRP4A53/UK.FB2 KRP1B57/UK.FB2 RTD-NET/UK.FB2 RTD-10/UK.FB2 RTD-20/UK.FB2 KLIC-DI KRCS01-4 K.RSS RS-SE UK.CWB90-2 UK.DT1 UK.CGS UK.CGM

Fully Flat Cassette Decoration Panel - White Fully Flat Cassette Decoration Panel - Sliver Fully Flat Cassette Decoration Panel - Old Style (FFQ-B9V looks) Integral PIR Sensor for Fully Flat cassette White decoration panel. Enables Energy Saving functions Integral PIR Sensor for Fully Flat Cassette Silver decoration panel. Enables Energy Saving functions Wireless remote controller for White Ceiling Decoration Panel Wireless remote controller for Silver Ceiling Decoration Panel Wireless remote for Fully Flat Cassette Old Style Decoration Panel Sealing member for decoration panel-FFQ,FXZQ Unit/Group adaptor PCB for remote on/off, status indication and temperature setting Adaptor PCB for Interlock to fresh air fan Modbus Interface PCB for Sky Air and VRV Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock Energy control PCB for Sky Air and VRV KNX Interface for Sky Air and VRV systems Remote room mounted temperature sensor Wireless room mounted temperature sensor and receiver Service and Configuration Tool for K.RSS Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm Condensing Unit Guard size 20-35 Condensing Unit Guard size 42-71

£198.00 £198.00 £170.00 £99.00 £99.00 £152.00 £152.00 £152.00 £91.00 £92.00 £100.00 £190.00 £235.00 £251.00 £185.00 £42.00 £89.00 £93.00 £37.00 £56.00 £214.00 £296.00

i) All fan coils supplied as standard with BRC1E52A wired remote controller with 7-day time clock ii) Infrared remote Trade price will be reduced by £76.00 if ordered instead of BRC1E52A iii) All fan coil units standard with auto restart after power failure iv) All fan coils suppled as standard with BYFQ60CW White fully flat decoration panel v) Minimum ambient operating temperatures: RXS

Cooling

Heating

-10°C

-15°C

Features: > Installed into suspended ceiling grids without cutting surrounding tiles > Home Leave setting maintains pre-set temperature during periods of extended absence > Dry programme: Daikin’s special dry programme reduces humidity in the rooms without variations in internal temperature > Vertical auto-swing function: flaps automatically swing up and down to ensure efficient air and temperature distribution which also prevents ceiling soiling > 3 fan speeds can be selected: high, medium and low > Suitable for Twin, Triple and Double Twin applications. Also suitable for multi model applications > Re-use of existing R22 and R407C piping possible

Price List 2015

29


SPLIT, SKY AIR HEAT PUMPS

FBQ / RZQG

Built in DC Ducted – Seasonal Smart Inverter Indoor Units

Single Phase

Capacity

Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency

Air Flow Rate External Static Pressure Dimensions

Weight Sound Pressure Sound Power

UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Low High / Standard Height Width Depth High / Low

kW kW kW kW kW kWh kW kWh

kWh m3/min Pa mm mm mm kg dBA dBA

Outdoor Units

FBQ100D

FBQ125D

FBQ140D

FBQ71D

FBQ100D

FBQ125D

7.76 5.32 6.80 7.50 A++ 6.80 6.16 386 A+ 6.00 4.31 1949 3.60 / 4.01 A/A TBC 18 / 12.5 150 / 30

10.80 7.44 9.50 10.80 A+ 9.50 5.87 566 A++ 11.30 4.78 3310 3.81 / 4.41 A/A TBC 29 / 23 150 / 40

13.60 14.90 9.30 10.25 12.00 13.40 13.50 15.50 A++ 12.00 6.11 687 A+ 12.71 4.28 4154 3.31 / 3.90 3.35 / 3.60 A/A A/B TBC TBC 34 / 23.5 150 / 50

7.76 5.32 6.80 7.50 A++ 6.80 6.16 386 A+ 6.00 4.31 1949 3.60 / 4.01 A/A TBC 18 / 15 150 / 30

10.80 7.44 9.50 10.80 A+ 9.50 5.87 566 A++ 11.30 4.78 3310 3.81 / 4.41 A/A TBC 32 / 23 150 / 40

13.60 14.90 9.30 10.25 12.00 13.40 13.50 15.50 A++ 12.00 6.11 687 A+ 12.71 4.28 4154 3.31 / 3.90 3.35 / 3.60 A/A A/B TBC TBC 34 / 23.5 150 / 50

245 1000

245 1400

1000

Height x Width x Depth

Interconnection Wiring Piping Connections Pipework

Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High

mm kg A A A inches m m m g/m kg dBA dBA

ECA Eligible

800 46

34 / 30 58

37 / 32 62

990 x 940 x 320 78 7.93 4 20 3/8 / 5/8 50 30 30 2.9 48 64

1430 x 940 x 320 102 1ph 9.97 12.87 4 4 32 32 3+E / 1.5 3/8 / 5/8 3/8 / 5/8 75 75 30 30 30 30 Refer to Installation Manual 4.0 4.0 50 51 66 67

Trade Fan Coil Price Trade Condensing Unit Price Total System Price

62

35 30 / 25 56

£860.00 £1,191.00 £2,051.00

990 x 940 x 320 80 16.43 4 32

2.98 4 16

3/8 / 5/8 75 30 30

3/8 / 5/8 50 30 30

4.0 52 69

2.9 48 64

46 34 / 30 58

£899.00 £1,514.00 £2,413.00

£1,063.00 £1,666.00 £2,729.00

£1,232.00 £1,901.00 £3,133.00

£860.00 £1,227.00 £2,087.00

62

6.18 4 20 3/8 / 5/8 75 30 30 4.0 52 69

£899.00 £1,584.00 £2,483.00

£1,063.00 £1,743.00 £2,806.00

£1,232.00 £2,002.00 £3,234.00

Notes:

Accessory Ref

Description

Trade Price

BRC4C65 BRC2E52

Wireless remote controller Wired Simplified remote controller (without auto swing) Recessed simplified remote (see page 85 for options) Unit/Group adaptor PCB for remote on/off, status indication and temperature setting Modbus Interface PCB for Sky Air and VRV Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock. Energy control PCB for Sky Air and VRV. KNX Interface for Sky Air and VRV systems Remote room mounted temperature sensor Wireless room mounted temperature sensor and receiver Service and Configuration Tool for K.RSS Return Air Chambers are available – contact your branch for details Supply Air Flanges are available – contact your branch for details Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU Condensate drip tray for use with Sky Air ODU - tray width 1100mm Condensing Unit Guard size 42-71 Condensing Unit Guard size 100-140 including RXYSQ

£152.00 £90.00 £180.00 £92.00 £190.00 £235.00 £251.00 £185.00 £42.00 £89.00 £93.00 POA POA £37.00 £46.00 £59.00 £296.00 £354.00

i) All fan coils supplied as standard with BRC1E52A wired remote controller with 7-day time clock ii) BRC4C65 Trade price will be reduced by £76.00 if ordered in place of the BRC1E52A iii) All fan coil units standard with auto restart after power failure iv) All fan coils supplied as standard with air filter v) Minimum ambient operating temperatures: RZQG RZQSG

> New chassis with height of 245mm makes the FBQ-D one of the slimmest medium static ducted on the market > Increased external static pressure up to 150 Pa > Flexibility to set the required fan curve manually or to automatically select the correct fan curve, assuring comfort at all times > Top efficiency, highest Energy label ranking in the market

Residential, Commercial and Industrial

Cooling

Heating

-15°C -15°C

-20°C -15°C

vi) FBQ-D fan coils require a separate 1ph power supply. Refer to install manual for details

Features:

30

37 / 32 62

1430 x 940 x 320 101 3ph 3.75 4.84 4 4 20 20 3+E / 1.5 3/8 / 5/8 3/8 / 5/8 75 75 30 30 30 30 Refer to Installation Manual 4.0 4.0 50 51 66 67

Accessories:

KRP4A53/UK.FB2 RTD-NET/UK.FB2 RTD-10/UK.FB2 RTD-20/UK.FB2 KLIC-DI KRCS01-4 K.RSS RS-SE UK.RAC UK.SAF UK.CWB90-2 UK.CWB140-2 UK.DT2 UK.CGM UK.CGL

1400

800 35 30 / 25 56

FBQ140D

RZQG71L9V1 RZQG100L9V1 RZQG125L9V1 RZQG140L9V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1

Dimensions Weight Electrical Details

Sound Pressure Sound Power

3 Phase

FBQ71D


SPLIT, SKY AIR HEAT PUMPS

FBQ / RZQSG

Built in DC Ducted – Seasonal Classic Inverter Indoor Units Capacity

Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency

Air Flow Rate External Static Pressure Dimensions

Weight Sound Pressure Sound Power

Single Phase UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Low High / Standard Height Width Depth High / Low

kW kW kW kW kW kWh kW kWh

kWh m3/min Pa mm mm mm kg dBA dBA

Outdoor Units Dimensions Weight Electrical Details

Interconnection Wiring Piping Connections Pipework

Sound Pressure Sound Power

3 Phase

FBQ71D

FBQ100D

FBQ125D

FBQ140D

FBQ100D

FBQ125D

7.28 4.99 6.80 7.50 A+ 6.80 5.84 408 A+ 6.00 4.01 2095 3.43 / 3.92 A/A TBC 18 / 12.5 150 / 30

10.80 7.44 9.50 10.80 A+ 9.50 5.61 593 A+ 7.60 4.15 2564 3.35 / 3.67 A/A TBC 29 / 23 150 / 40

13.60 14.90 9.30 10.25 12.00 13.40 13.50 15.50 A 12.00 5.47 768 A+ 7.60 4.01 2653 3.23 / 3.63 3.06 / 3.40 A/A B/B TBC TBC 34 / 23.5 150 / 50

10.80 7.44 9.50 10.80 A+ 9.50 5.61 593.00 A+ 7.60 4.15 2564.00 3.35 / 3.67 A/A TBC 29 / 23 150 / 40

13.60 14.90 9.30 10.25 12.00 13.40 13.50 15.50 A 12.00 5.47 768.00 A+ 7.60 4.01 2653.00 3.23 / 3.63 3.06 / 3.40 A/A B/B TBC TBC 34 / 23.5 150 / 50 245 1400 800 46 37 / 32 62

245 1000

1400 800

35 30 / 25 56

46 34 / 30 58

37 / 32 62

62

34 / 30 58

FBQ140D

RZQSG71L3V1 RZQSG100L9V1 RZQSG125L9V1 RZQSG140L9V1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1 Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High

Trade Fan Coil Price Trade Condensing Unit Price Total System Price

mm kg A A A inches m m m g/m kg dBA dBA

770 x 900 x 320 67 8.46 4 20 3/8 / 5/8 50 15 30 2.75 49 65 £860.00 £820.00 £1,680.00

990 x 940 x 320 81 1ph 11.73 15.29 4 4 32 32 3+E / 1.5 3/8 / 5/8 3/8 / 5/8 50 50 30 30 30 30 Refer to Installation Manual 2.9 2.9 53 54 69 70 £899.00 £1,135.00 £2,034.00

£1,063.00 £1,245.00 £2,308.00

1430 x 940 x 320 102 18.15 4 32 3/8 / 5/8 50 30 30 4.0 53 69 £1,232.00 £1,386.00 £2,618.00

990 x 940 x 320 1430 x 940 x 320 82 101 3ph 4.39 5.72 6.79 4 4 4 20 20 20 3+E / 1.5 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 50 50 50 30 30 30 30 30 30 Refer to Installation Manual 2.9 2.9 4.0 53 54 53 69 70 69 £899.00 £1,170.00 £2,069.00

£1,063.00 £1,282.00 £2,345.00

£1,232.00 £1,428.00 £2,660.00

Price List 2015

31


SPLIT, SKY AIR HEAT PUMPS

FBQ & FDXS-F / RXS

Built in DC Ducted & Slim Ducted – Inverter Indoor Units

DC Ducted

Capacity

Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency

Air Flow Rate External Static Pressure Dimensions

Weight Sound Pressure Sound Power

UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Low High / Standard Height Width Depth High / Low

kW kW kW kW kW kWh kW kWh

kWh m3/min Pa mm mm mm kg dBA dBA

Outdoor Units Dimensions Weight Electrical Details

Height x Width x Depth

Interconnection Wiring Piping Connections Pipework

Sound Pressure Sound Power

Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High

mm kg A A A inches m m m g/m kg dBA dBA

Trade Fan Coil Price Trade Condensing Unit Price Total System Price

Slim Ducted

FBQ35D

FBQ50D

FBQ60D

FDXS25F

FDXS35F

FDXS50F9

FDXS60F

3.32* 2.93* 3.40 4.00 A++ 3.40 6.17 193 A+ 2.90 4.07 998 3.99 / 4.02 A/A tbc 15 / 10.5

4.89* 3.60* 5.00 5.50 A++ 5.00 6.21 282 A+ 4.40 4.06 1517 3.52 / 3.83 B/A tbc 15 / 10.5 150 / 30 245

5.57* 4.10* 5.70 7.00 A+ 5.70 5.86 340 A+ 4.60 4.01 1606 3.45 / 3.71 B/A tbc 18 / 12.5

2.35 1.81 2.40 3.20 A+ 2.40 5.63 149 A+ 2.60 4.24 858 3.69 / 4 A/A 325 8.7 / 7.3 30.0

3.32 2.26 3.40 4.00 A 3.40 5.21 228 A 2.90 3.88 1047 3.21 / 3.48 A/B 530 8.7 / 7.3 30.0

4.81 3.08 5.00 5.80 A+ 5.00 5.72 306 A 4.00 3.93 1425 3.03 / 3.1 B/D 825 12 / 10 40.0

5.86 3.97 6.00 7.00 A 6.00 5.51 381 A 4.60 3.80 1693 2.91 / 3.21 C/C 1030 16 / 13.5 40.0

700

200 1000

750

28

620

35 / 29 60

35 / 29 60

56 30 / 25 55

RXS35L3

RXS50L

RXS60L

550 x 765 x 285 735 x 825 x 300 735 x 825 x 300 34 47 48 1ph (refer to databook) 4.6* 7.2* 9.2* 4.3 6.8 9.4 10 20 20 3+E / 1.5 3+E / 2.5 1/4 / 3/8 1/4 / 1/2 1/4 / 1/2 20 30 30 15 20 20 10 10 10 20 1.2 1.7 1.5 48 48 49 61 62 62 £515.00 £552.00 £1,067.00

£541.00 £694.00 £1,235.00

£600.00 £740.00 £1,340.00

21

30

35 / 31 53

35 / 31 53

37 / 33 55

38 / 34 56

RXS25L3

RXS35L3

RXS50L

RXS60L

550 x 765 x 285 34

550 x 765 x 285 735 x 825 x 300 735 x 825 x 300 34 47 48 1ph 3.90 4.90 7.10 9.20 3.3 4.3 6.8 9.4 10 10 20 20 3+E / 1.5 3+E / 2.5 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2 1/4 / 1/2 20 20 30 30 15 15 20 20 10 10 10 10 20 1.0 1.2 1.7 1.5 46 48 48 49 59 61 62 62 £394.00 £476.00 £870.00

Accessories:

£441.00 £552.00 £993.00

£477.00 £694.00 £1,171.00

Accessory Ref

Description

Trade Price

Wireless remote controller Wired Simplified remote controller Recessed simplified remote (see page 85 for options) Unit/Group adaptor PCB for remote on/off, status indication and temperature setting Modbus Interface PCB for Sky Air and VRV Enhanced function PCB for Sky Air & VRV. Duty rotation, Lead Lag control & heating interlock Energy control PCB for Sky Air and VRV KNX Interface for Sky Air and VRV systems Remote room mounted temperature sensor Wireless room mounted temperature sensor and receiver Service and Configuration Tool for K.RSS Return Air Chambers are available – contact your branch for details Supply Air Flanges are available – contact your branch for details Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm Condensing Unit Guard size 20-35 Condensing Unit Guard size 42-71

£152.00 £80.00 £180.00 £92.00 £190.00 £235.00 £251.00 £185.00 £42.00 £89.00 £93.00 POA POA £37.00 £56.00 £214.00 £296.00

i) FBQ & FDXS fan coils supplied as standard with BRC1E52A wired remote controller with 7-day time clock ii) BRC4C65 Trade price will be reduced by £76.00 if ordered in place of the BRC1E52A iii) All fan coil units standard with auto restart after power failure iv) All fan coils supplied as standard with air filter v) Minimum ambient operating temperatures: RXS

Cooling

Heating

-10°C

-15°C

vi) FBQ-D fan coils require a separate 1ph power supply. Refer to install manual for details vii) * Provisional data

Features: > Fan speed: 5 fan speeds can be selected, high to super low > Connection to multi outdoor possible > Re-use of existing R22 and R407C piping possible

32

£524.00 £740.00 £1,264.00

Notes:

BRC4C65 BRC2E52 KRP4A53/UK.FB2 RTD-NET/UK.FB2 RTD-10/UK.FB2 RTD-20/UK.FB2 KLIC-DI KRCS01-4B K.RSS RS-SE UK.RAC UK.SAF UK.CWB90-2 UK.DT1 UK.CGS UK.CGM

1150

800

Residential, Commercial and Industrial


AVAILABLE SUMMER 2015

Vertical Chassis Unit

Indoor Units

Vertical Ducted

Capacity

Seasonal Efficiency (EN14825 COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency

Air Flow Rate External Static Pressure Dimensions

Weight Sound Pressure Sound Power

UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Low High / Nominal Height Width Depth High / Low

Outdoor Units Dimensions Weight Electrical Details

Height x Width x Depth

Interconnection Wiring Piping Connections Pipework

Sound Pressure Sound Power

SPLIT, SKY AIR HEAT PUMPS

FNQ-A / RXS

NEW

Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High

kW kW kW kW kW kWh kW kWh

kWh m3/min Pa mm mm mm kg dBA dBA

mm kg

FNQ25A

FNQ35A

FNQ50A

FNQ60A

2.35* 1.81* 2.40 3.20 A+* 2.40* 5.63* 149.00* A+* 2.60* 4.24* 858* 3.69 / 4.00* A / A* 325*

3.32* 2.26* 3.40 4.00 A* 3.40* 5.21* 228.00* A* 2.90* 3.88* 1047* 3.21 / 3.48* A / B* 530*

4.81* 3.08* 5.00 5.80 A+* 5.00* 5.72* 306.00* A* 4.00* 3.93* 1425* 3.03 / 3.10* B / D* 825*

5.86* 3.97* 6.00 7.00 A* 6.00* 5.51* 381.00* A* 4.60* 3.80* 1693* 2.91 / 3.21* C / C* 1031*

8.7 / 7.3* 30 / 10* 620* 750* 200*

16 / 13.5* 44 / 15* 620* 1150* 200*

21* TBC TBC

21* TBC TBC

30* TBC TBC

30* TBC TBC

RXS25L3 550 x 765 x 285 34

RXS35L3 550 x 765 x 285 34

RXS50L 735 x 825 x 300 47

RXS60L 735 x 825 x 300 48

3.90* 3.3* 10

4.90* 4.3* 10

7.10* 6.8* 20

9.20* 9.4* 20

1/4 / 3/8 20 15 10

1/4 / 3/8 20 15 10

1/4 / 1/2 30 20 10

1/4 / 1/2 30 20 10

1.0 46 59

1.2 48 61

1.7 48 62

1.5 49 62

£407.00 £476.00 £883.00

£503.00 £552.00 £1,055.00

£586.00 £694.00 £1,280.00

£646.00 £740.00 £1,386.00

1ph A A A

3+E / 1.5 inches m m m g/m kg dBA dBA

Trade Fan Coil Price Trade Condensing Unit Price Total System Price

3+E / 2.5

20

Accessories:

Notes:

Accessory Ref

Description

Trade Price

BRC4C65 BRC2E52

Wireless remote controller Wired Simplified remote controller (without auto swing) Recessed simplified remote (see page 85 for options) Unit/Group adaptor PCB for remote on/off, status indication and temperature setting Modbus Interface PCB for Sky Air and VRV Enhanced function PCB for Sky Air & VRV. Duty rotation, Lead Lag control & heating interlock Energy control PCB for Sky Air and VRV KNX Interface for Sky Air and VRV systems Remote room mounted temperature sensor Wireless room mounted temperature sensor and receiver Service and Configuration Tool for K.RSS Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm Condensing Unit Guard size 20-35 Condensing Unit Guard size 42-71

£152.00 £80.00 £180.00 £92.00 £190.00 £235.00 £251.00 £185.00 £42.00 £89.00 £93.00 £37.00 £56.00 £214.00 £296.00

KRP4A53/UK.FB2 RTD-NET/UK.FB2 RTD-10/UK.FB2 RTD-20/UK.FB2 KLIC-DI KRCS01-4B K.RSS RS-SE UK.CWB90-2 UK.DT1 UK.CGS UK.CGM

i) Fan-coils supplied with BRC1E52A hard wired remote ii) All fan coil units standard with auto restart after power failure iii) Fan-coils supplied as standard with air filter iv) Minimum ambient operating temperature: RXS

Cooling

Heating

-10°C

-15°C

v) * Provisional data

Features: > Requires very little installation space > Low height makes it ideal for installation beneath window > Connect to multi for residential solution > Connect to Sky Air for twin, triple or double applications > External static pressure of up to 44Pa

Price List 2015

33


SPLIT, SKY AIR HEAT PUMPS

FDQ

High Static Ducted – Seasonal Smart, Classic & Super Inverter Indoor Units Capacity

Seasonal Efficiency (EN14825) COOLING Seasonal Efficiency (EN14825) HEATING Nominal Efficiency

Air Flow Rate External Static Pressure Dimensions

Weight Sound Pressure Sound Power

UK Total Cooling UK Sensible Cooling Nominal Cooling Nominal Heating Energy Label Pdesign SEER Annual Energy Consumption Energy Label Pdesign SCOP Annual Energy Consumption EER / COP Energy Label Annual Energy Consumption High / Low High / Nominal Height Width Depth High / Low

kW kW kW kW kW kWh kW kWh

kWh m3/min Pa mm mm mm kg dBA dBA

Outdoor Units Dimensions Weight Electrical Details

Interconnection Wiring Piping Connections Pipework

Sound Pressure Sound Power

Height x Width x Depth Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High

mm kg A A A inches m m m g/m kg dBA dBA

Trade Fan Coil Price Trade Condensing Unit Price Total System Price

Single Phase

3 Phase

Single Phase

3 Phase

FDQ125C

FDQ125C

FDQ125C

FDQ125C

FDQ200B

FDQ250B

13.60 9.30 12.00 13.50 A+ 12.00 5.81 722 A+ 12.71 4.21 4226 3.75 / 3.83 A/A 1600 39 / 28 200 / 50 300 1400 700 45 40 / 33 66

13.60 9.30 12.00 13.50 A+ 12.00 5.81 722 A+ 12.71 4.21 4226 3.75 / 3.83 A/A 1600 39 / 28 200 / 50 300 1400 700 45 40 / 33 66

13.60 9.30 12.00 13.50 A 12.00 5.20 807 A 7.60 3.90 2728 3.21 / 3.51 A/B 1870 39 / 28 200 / 50 300 1400 700 45 40 / 33 66

13.60 9.30 12.00 13.50 A 12.00 5.20 807 A 7.60 3.90 2728 3.21 / 3.51 A/B 1600 39 / 28 200 / 50 300 1400 700 45 40 / 33 66

19.40 16.30 20.00 23.00 3.21 / 3.41 A/B 3115 69 / 69 250 / 250 450 1400 900 89 45 / 45 81

23.50 20.70 25.00 27.00 2.81 / 3.21 C/C 4290 89 / 89 250 / 250 450 1400 900 94 47 / 47 82

RZQG125L9V1

RZQG125L8Y1

RZQSG125L9V1

RZQSG125L8Y1

RZQ200C

RZQ250C

1430 x 940 x 320 102 1ph - see notes 14.80 4 32

1430 x 940 x 320 990 x 940 x 320 101 81 3ph - see notes 1ph - see notes 4.89 17.30 4 4 20 32 3+E / 1.5 3/8 / 5/8 3/8 / 5/8 75 50 30 30 30 30 Refer to Installation Manual 4.0 2.9 51 54 67 70

3/8 / 5/8 75 30 30 4.0 51 67 £1,163.00 £1,666.00 £2,829.00

£1,163.00 £1,743.00 £2,906.00

£1,163.00 £1,245.00 £2,408.00

990 x 940 x 320 82 3ph - see notes 5.72 4 20 3/8 / 5/8 50 30 30 2.9 54 70

1680 x 930 x 765 1680 x 930 x 765 183 184 3ph - see notes 4.61 6.35 4 4 25 25 3+E / 1.5 3/8 / 7/8 1/2 / 7/8 100 100 30 30 30 30 Refer to Installation Manual 8.3 9.3 57 57 78 78

£1,163.00 £1,282.00 £2,445.00

Accessories:

£1,561.00 £2,576.00 £4,137.00

£1,912.00 £2,698.00 £4,610.00

Notes:

Accessory Ref

Description

Trade Price

BRC4C65 EKRORO3 KRP4A53/UK.FB2 RTD-NET/UK.FB2 RTD-10/UK.FB2 RTD-20/UK.FB2 KRCS01-4 KLIC-DI DTA112B51 UK.CWB90-2 UK.CWB140-2 UK.DT2 UK.CGL

Wireless remote controller Remote on/off control interface kit Unit/Group adaptor PCB for remote on/off, status indication and temperature setting Modbus Interface PCB for Sky Air and VRV Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock Energy control PCB for Sky Air and VRV Remote room mounted temperature sensor KNX Interface for Sky Air and VRV systems Adaptor PCB for interface to Daikin centralised control systems Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU Condensate drip tray for use with Sky Air ODU - tray width 1100mm Condensing Unit Guard size 100-140 including RXYSQ

£152.00 £29.00 £92.00 £190.00 £235.00 £251.00 £42.00 £185.00 £89.00 £37.00 £46.00 £59.00 £354.00

Features: > High static units for longer ducted runs > Up to 250Pa External Static Pressure > Auto balancing air flow / ESP on commissioning > Comms, computer and server room cooling possible (Seasonal Smart only) > Super inverter technology: reduces power consumption by up to 70% compared to non inverter units > Selectable evaporating & condensing temperature for greater operating efficiency (Seasonal Smart only)

34

Super Inverter (3 phase)

Residential, Commercial and Industrial

i) All fan coils supplied as standard with BRC1E52A wired remote controller with 7-day time clock ii) BRC4C65 Trade price will be reduced by £76.00 if ordered in place of the BRC1E52A iii) Replacement technology not applicable to RZQ200 and RZQ250 iv) All fan coil units standard with auto restart after power failure v) All fan coils supplied as standard with air filter vi) Minimum ambient operating temperatures: RZQG RZQSG RZQ

Cooling

Heating

-15°C -15°C -5°C

-20°C -15°C -15°C

vii) FDQ Fan Coil unit requires a separate 15 amp power supply


SPLIT, SKY AIR HEAT PUMPS


SPLIT, SKY AIR HEAT PUMPS

I W I- F O L TR CO N A P P IA V

Multi Series Multi Series Inverters offer the ability to connect up to 5 fan coils to one outdoor unit. With the MXS range it is possible to install indoor units throughout a house or small commercial premises and only use 1 outdoor unit. Each indoor unit will have it’s own controller and will be able to operate in heating or cooling. Heating & cooling Connectable Indoor Units

Wall mounted FTXG-L

CTXS-K

Floor standing

FTXS-K

FTXS-G

FTX-J3

FVXG-K

FVXS-F

Flexi type

Round flow cassette

Fully flat cassette

FLXS-B(9)

FCQG-F

FFQ-C

Concealed ceiling FDXS-F(9)

Ceiling Concealed suspended floor standing

FDBQ-B/FBQ-D

FHQ-C

FNQ-A

20 25 35 50 15 35 20 25 35 42 50 60 71 20 25 35 25 35 50 25 35 50 25 35 50 60 35 50 60 25 35 50 60 25 35 50 60 25 35 50 60 35 50 60 25 35 50 60

2MXS40H 2MXS50H 3MXS40K 3MXS52E 3MXS68G 4MXS68F 4MXS80E 5MXS90E

● ● ●

Daikin’s new Multi Selection Tool is a fast and simple way to select your combinations for MXS Series outdoor units. The online tool has four simple steps: > select number of rooms > select capacity per room > select capacity of outdoor > select type of indoor & input pipe run & level difference It has in-built checks to ensure capacity, pipe length and level difference cannot exceed maximum for selected outdoor unit and generates a report showing full energy label for specific combination and pictures of all equipment selected. This can be used by installers to select Multi systems, and also to show end-users the configuration of the system. Go to www.daikineurope.com/multiselection

Multi Split & Mini VRV Fan Coils Emura Wall Mounted Fan Coil Units Trade Fan Coil Unit Price

FTXG20LW FTXG25LW FTXG35LW FTXG50LW FTXG20LS FTXG25LS FTXG35LS FTXG50LS £262.00 £276.00 £310.00 £409.00 £313.00 £329.00 £369.00 £488.00

Wall Mounted Fan Coil Units Trade Fan Coil Unit Price

CTXS15K £146.00

FTXS20K £154.00

FTXS25K £165.00

Wall Mounted Low Inverter Fan Coil Units Trade Fan Coil Unit Price

FTX20J3 £123.00

FTX25J3 £136.00

FTX35J3 £154.00

Flexi Fan Coil Units Trade Fan Coil Unit Price

FLXS25B £376.00

FLXS35B9 £423.00

FLXS50B £459.00

Nexura Floor Standing Fan Coil Units Trade Fan Coil Unit Price

FVXG25K £631.00

FVXG35K £679.00

FVXG50K £744.00

Floor Standing Fan Coil Units Trade Fan Coil Unit Price

FVXS25F £523.00

FVXS35F £564.00

FVXS50F £616.00

Compact Roundflow Cassette Fan Coil Units Trade Fan Coil Unit Price

FCQG35F £ 683.00

FCQG50F £699.00

FCQG60F £743.00

600 Sq 600 Sq 4-way blow Cassette Fan Coil Units Trade Fan Coil Unit Price

FFQ25C £636.00

FFQ35C £696.00

FFQ50C £766.00

Ceiling Suspended Fan Coil Units Trade Fan Coil Unit Price

FHQ35C £668.00

FHQ50C £722.00

FHQ60C £792.00

Ducted Fan Coil Units Trade Fan Coil Unit Price

FDBQ25B £424.00

FBQ35D £515.00

FBQ50D £541.00

FBQ60D £600.00

Slim Ducted Fan Coil Units Trade Fan Coil Unit Price

FDXS25F £394.00

FDXS35F £441.00

FDXS50F9 £477.00

FDXS60F £524.00

FNQ15A £407.00

FNQ35A £503.00

FNQ50A £586.00

FNQ60A £646.00

NEW AVAILABLE SUMMER 2015

36

Vertical Chassis Unit Trade Fan Coil Unit Price

Residential, Commercial and Industrial

FTXS35K £189.00

FTXS42K £212.00

FTXS50K £294.00

FTXS60G £300.00

FTXS71G £400.00

Notes: FFQ60C £809.00

i) Accessories for fan coils - refer to pair system pages ii) All fan coil units standard with auto restart after power failure iii) All fan coil units supplied as standard with remote controller iv) FDXS fan coil units supplied as standard with air filter v) 2MXS40-50H can only be used with FTXG, FTXS, FTX, FDXS, FVXG, FVXS, FLXS fan coil units vi) One wifi adaptor per fan coil for online control


Multi Series Inverters Outdoor Units Capacity Dimensions

Weight Electrical Details

Refrigerant Circuit Sound Pressure Sound Power Piping Limits

Nominal Cooling Nominal Heating Height Width Depth Power Supply

Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge High

Maximum Length Maximum Vertical Rise Piping Connections Liquid Gas Number of Connected Indoor Units

kW kW mm mm mm kg Phase Hz V amps amps amps kg dBA m m inches inches

Trade Condensing Unit Price

2MXS40H

2MXS50H

3MXS40K

3MXS52E

3MXS68G

4MXS68F

4MXS80E

5MXS90E

4.00 4.40 550 765 285 38

5.00 5.70 550 765 285 42

4.00 4.60 735 936 300 49

5.20 6.80 735 936 300 49

6.80 8.60 735 936 300 58

6.80 8.60 735 936 300 58

8.00 9.60 770 900 320 72

9.00 10.40 770 900 320 73

4 20

4 20

4 16

4 16

1.2 47 62 30 15 2x 1/4 2x 3/8 2

1.6 48 63 30 15 2x 1/4 3/8 1/2 2

£998.00

£1,104.00

1ph 50 230 Refer to Multi Combination Tables 4 4 4 4 16 20 20 20 R410a 2.0 2.0 2.6 2.6 46 46 48 48 59 59 61 61 50 50 60 60 15 15 15 15 3x 1/4 3x 1/4 3x 1/4 4x 1/4 2x3/8 1/2 2x3/8 1/2 3/8 2x1/2 2x3/8 2x1/2 3 3 3 4 £1,040.00

£1,156.00

£1,637.00

Accessories:

3.0 3.0 48 52 62 66 70 75 15 15 4x 1/4 5x 1/4 3/8 1/2 2x5/8 2x3/8 1/2 2x5/8 4 5

£1,766.00

£1,989.00

£2,141.00

Notes:

Accessory Ref

Description

Trade Price

UK.CWB90-2 UK.DT1 UK.DT2 UK.CGM

Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensate drip tray for use with Split ODU - tray width 800mm Condensate drip tray for use with Sky Air ODU - tray width 1100mm Condensing Unit Guard size 42-71

£37.00 £56.00 £59.00 £296.00

i) Minimum ambient operating temperatures: 2MXS40, 50 3MXS40, 52, 68 4MXS68, 80 5MXS90

Cooling

Heating

10°C -10°C -10°C -10°C

-15°C -15°C -15°C -15°C

Please note: RXYSQ units are subject to VRV discount level

RXYSQ-P8

Mini VRV for Residential Applications Outdoor Units

RXYSQ4P8V1

RXYSQ5P8V1

RXYSQ6P8V1

kW kW mm mm mm kg Phase Hz V amps amps amps

12.60 14.20 1345 900 320 120

15.50 18.00 1345 900 320 120

kg dBA dBA m m inches inches

Capacity Index Limit Number of Connected Indoor Units

4.0 50 66 115 data book 3/8 5/8 50~130 8

14.00 16.00 1345 900 320 120 1ph 50 230 Refer to Multi Combination Tables 4 32 R410a 4.0 51 67 135 data book 3/8 5/8 62.5~162.5 10

4.0 53 69 145 data book 3/8 3/4 70~182 13

Trade Condensing Unit Price

£2,735.00

£3,074.00

£3,431.00

Capacity Dimensions

Weight Electrical Details

Refrigerant Circuit Sound Pressure Sound Power Piping Limits Piping Connections

Nominal Cooling Nominal Heating Height Width Depth Power Supply

Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge High High Maximum Length Maximum Vertical Rise Liquid Gas

4 32

4 32

New low height mini VRV available Summer 2015 see page 68

Accessories:

Notes:

Accessory Ref

Description

Trade Price

i) Minimum ambient operating temperatures:

BPMKS967A2 BPMKS967A3 KHRQ22M20T

Branch Provider Kit - 2 fan coil units Branch Provider Kit - 3 fan coil units R410a 2 Pipe Refnet Joint

£356.00 £380.00 £29.00

RXYSQ-P8

Cooling

Heating

-5°C

-20°C

Price List 2015

37

SPLIT, SKY AIR HEAT PUMPS

MXS-E/F/G/H/K


SPLIT, SKY AIR HEAT PUMPS

Possible Combinations

Twin, Triple and Double Twin Outdoor Units Outdoor Units

Nominal Cooling kW

Nominal Heating kW

6.80 6.80 9.50 9.50 9.50 9.50 12.00 12.00 12.00 12.00 12.00 12.00 13.40 13.40 13.40 13.40 13.40 13.40 19.50 19.50 19.50 19.50 25.00 25.00

7.50 7.50 10.80 10.80 10.80 10.80 13.50 13.50 13.50 13.50 13.50 13.50 15.50 15.50 15.50 15.50 15.50 15.50 23.40 23.40 23.40 23.40 27.00 27.00

RZQG71L9V1 / Y1 RZQSG71L3V1 / Y1 RZQG100L9V1 / Y1 RZQG100L9V1 / Y1 RZQSG100L9V1 / Y1 RZQSG100L9V1 / Y1 RZQG125L9V1 / Y1 RZQG125L9V1 / Y1 RZQG125L9V1 / Y1 RZQSG125L9V1 / Y1 RZQSG125L9V1 / Y1 RZQSG125L9V1 / Y1 RZQG140L9V1 / LY1 RZQG140L9V1 / LY1 RZQG140L9V1 / LY1 RZQSG140L9V1 / LY1 RZQSG140L9V1 / LY1 RZQSG140L9V1 / LY1 RZQ200 RZQ200 RZQ200 RZQ200 RZQ250 RZQ250

Possible Combinations 35 35 50 35 50 35 60 50 35 60 50 35 71 50 35 71 50 35 100 60 71 50 125 60

+ + + + + + + + + + + + + + + + + + + + + + + +

35 35 50 35 50 35 60 50 35 60 50 35 71 50 35 71 50 35 100 60 71 50 125 60

+

35

+

35

+ +

50 35

+

35

+ +

50 35

+

35

+ +

50 35

+

35

+ +

50 35

+

35

+ + +

60 71 50

+

50

+

60

+

60

Notes:

Model Types FFQ, FCQG, FBQ, FDXS, FHQ, FNQ FFQ, FCQG, FBQ, FDXS, FHQ, FNQ FFQ, FCQG, FBQ, FDXS, FHQ, FNQ FFQ, FCQG, FBQ, FDXS, FHQ, FNQ FFQ, FCQG, FBQ, FDXS, FHQ, FNQ FFQ, FCQG, FBQ, FDXS, FHQ, FNQ FFQ, FCQG, FBQ, FDXS, FHQ, FNQ FFQ, FCQG, FBQ, FDXS, FHQ, FNQ FFQ, FCQG, FBQ, FDXS, FHQ, FNQ FFQ, FCQG, FBQ, FDXS, FHQ, FNQ FFQ, FCQG, FBQ, FDXS, FHQ, FNQ FFQ, FCQG, FBQ, FDXS, FHQ, FNQ FCQG, FCQHG, FBQ, FHQ, FUQ, FAQ FFQ, FCQG, FBQ, FDXS, FHQ, FNQ FFQ, FCQG, FBQ, FDXS, FHQ, FNQ FCQG, FCQHG, FBQ, FHQ, FUQ, FAQ FFQ, FCQG, FBQ, FDXS, FHQ, FNQ FFQ, FCQG, FBQ, FDXS, FHQ FCQG, FCQHG, FBQ, FHQG, FUQ, FAQ FFQ, FCQG, FBQ, FDXS, FHQ, FNQ FCQG, FCQHG, FBQ, FHQ, FUQ, FAQ FFQ, FCQG, FBQ, FDXS, FHQ, FNQ FCQG, FCQHG, FBQ, FHQ, FUQ, FDQ FFQ, FCQG, FBQ, FDXS, FHQ, FNQ

These systems allow a mixture of fan coil types and sizes on the same condensing unit. Each system is operated on the Master and Slave principle from one remote controller. As the number of possible combinations is so great, we are unable to show each system as separate prices within the price list. To calculate a system price please refer to the next pages for individual fan coil and condensing unit prices and remember to add the pipework joints listed as accessory items on the following pages. Each fan coil unit includes within its price for a remote controller. As a complete system requires only one controller, you will need to subtract the controller cost from all but one fan coil on each system. * For energy labels & SEER on systems up to 12kW go to www.daikineurope.com.energylabel

EXAMPLE: TRADE EACH TRADE TOTAL Heat pump triple system using the following: 3 No FCQG71-F Fan coil units £829.00 £2,487.00 1 No RZQ200C Condensing unit £2,578.00 £2,578.00 1 No KHRQ250H7 Pipework branch kit £81.00 £81.00 2 No BRC1E52A Remote controller (Credit) -£76.00 -£152.00 TOTAL £4,994.00

Fan Coils

Twin, Triple and Double Twin Outdoor Units Wall Mounted Fan Coil Units Trade Fan Coil Unit Price

FAQ71C £749.00

FAQ100C £808.00

Ceiling Suspended Fan Coil Units Trade Fan Coil Unit Price

FHQ35C £666.00

FHQ50C £722.00

FHQ60C £792.00

FHQ71C £926.00

FHQ100C £983.00

Compact Roundflow Cassette Fan Coil Units Trade Fan Coil Unit Price

FCQG35F £683.00

FCQG50F £699.00

FCQG60F £743.00

FCQG71F £787.00

FCQG100F FCQG125F £890.00 £972.00

High COP Roundflow Cassette Fan Coil Units Trade Fan Coil Unit Price

FCQHG71F FCQHG100F FCQHG125F £787.00 £890.00 £972.00

Notes: i) Each of the fan coil units price includes one remote controller BRC1E52A

600 Sq 4-way Blow Cassette Fan Coil Units Trade Fan Coil Unit Price

FFQ35C £696.00

FFQ50C £766.00

FFQ60C £809.00

Under Ceiling 4-way Blow Cassette Fan Coil Units Trade Fan Coil Unit Price

FUQ71C £857.00

FUQ100C £940.00

FUQ125C £1,037.00

DC Ducted Fan Coil Units Trade Fan Coil Unit Price

FBQ35D £515.00

FBQ50D £541.00

FBQ60D £600.00

FBQ71D £860.00

Slim Ducted Fan Coil Units Trade Fan Coil Unit Price

FDXS25F £394.00

FDXS35F £441.00

FDXS50F9 £477.00

FDXS60F £524.00

High Static Ducted Fan Coil Units Trade Fan Coil Unit Price

FDQ125C £1,244.00 FNQ35A £503.00

FNQ50A £586.00

FNQ60A £646.00

NEW AVAILABLE SUMMER 2015

38

Vertical Chassis Unit Trade Fan Coil Unit Price

FHQ125C £1,229.00

FNQ15A £407.00

Residential, Commercial and Industrial

ii) FBQ-D series fan coil units require a separate 1 ph power supply FBQ100D £899.00

FBQ125D £1,063.00

iii) Self cleaning deco-panel BYCQ140DG is compatible on cassettes used in twin, triple and double twin applications iv) For seasonal data on Twin, Triple and Double Twin applications please consult www.daikineurope.com/ energylabel v) Accessories for fan coils and condensing units - refer to pair system pages


SPLIT, SKY AIR HEAT PUMPS

RZQG

Seasonal Smart Inverter Outdoor Units

Dimensions

Weight Electrical Details

Interconnection Wiring Piping Connections Pipework

Sound Pressure Sound Power

Height Width Depth Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High

mm mm mm kg A A A inches m m m g/m kg dBA

Trade Condensing Unit Price

Seasonal Smart Inverter

Seasonal Smart Inverter

Single Phase

3 Phase

RZQG 71L9V1 990 940 320 78

RZQG 100L9V1 1430 940 320 102

RZQG 125L9V1 1430 940 320 102

RZQG 140L9V1 1430 940 320 102

RZQG71L8Y1 990 940 320 80

RZQG100L8Y1 1430 940 320 101

1ph data book

RZQG125L8Y1 1430 940 320 101

Super Inverter RZQG140LY1 1430 940 320 101

RZQ200C

RZQ250C

1680 930 765 183

1680 930 765 184

3ph data book

4 20

4 32

4 32

4 32

3/8 / 5/8 50

3/8 / 5/8 75

3/8 / 5/8 75

3/8 / 5/8 75

2.9 48 64

4.0 50 66

4.0 51 67

4.0 52 69

£1,191.00

£1,514.00

£1,666.00

£1,901.00

4 16

4 20

3ph data book 4 20

3+E / 1.5 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 50 75 75 30 30 Refer to Installation Manual 2.9 4.0 4.0 48 50 51 64 66 67 £1,227.00

£1,584.00

£1,743.00

4 20

4 25

4 25

3/8 / 5/8 75

3/8 / 7/8 100

1/2 / 7/8 100

4.0 52 69

8.3 57 78

9.3 57 78

£2,002.00

£2,576.00

£2,698.00

Notes:

Accessories: Accessory Ref

Description

Trade Price

KHRQ22M20T KHRQ127H KHRQ250H7 UK.CWB90-2 UK.CWB140-2 UK.DT2 UK.CGM UK.CGL

R410a 2 Pipe Refnet Joint Triple Refnet Joint - RZQS71~140,RZQ100~140 Triple Refnet Joint - RZQ200~250 Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU Condensate drip tray for use with Sky Air ODU - tray width 1100mm Condensing Unit Guard size 42-71 Condensing Unit Guard size 100-140 including RXYSQ

£29.00 £65.00 £81.00 £37.00 £46.00 £59.00 £296.00 £354.00

i) Accessories for fan coils and condensing units - refer to pair system pages

RZQSG

Seasonal Classic Inverter Outdoor Units

Seasonal Classic Inverter

Seasonal Classic Inverter

Single Phase Dimensions

Weight Electrical Details

Interconnection Wiring Piping Connections Pipework

Sound Pressure Sound Power

Height Width Depth Power Supply Running Current Starting Current Max Fuse Size Core / Cable size Liquid / Gas Maximum Length Maximum Vertical Rise Precharged to Additional Charge Holding Charge High

Trade Condensing Unit Price

mm mm mm kg A A A inches m m m g/m kg dBA

RZQSG71L3V1 770 900 320 67

4 20

RZQSG100L9V1 RZQSG125L9V1 990 990 940 940 320 320 81 81 1ph data book 4 4 32 32

3/8 / 5/8 50

3/8 / 5/8 50

2.75 49 65

2.9 53 69

£820.00

£1,135.00

3 Phase RZQSG140L9V1 1430 940 320 102

RZQSG100L8Y1 990 940 320 82

4 4 32 20 3+E / 1.5 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 50 50 50 30 30 Refer to Installation Manual 2.9 4.0 2.9 54 53 53 70 69 69

£1,245.00

£1,386.00

RZQSG125L8Y1 990 940 320 82 3ph data book 4 20

RZQSG140LY1 1430 940 320 101

3/8 / 5/8 50

3/8 / 5/8 50

2.9 54 70

4.0 53 69

£1,282.00

£1,428.00

£ 1,170.00

4 20

Notes:

Accessories: Accessory Ref

Description

Trade Price

KHRQ22M20T KHRQ127H KHRQ250H7 UK.CWB90-2 UK.CWB140-2 UK.DT2 UK.CGM UK.CGL

R410a 2 Pipe Refnet Joint Triple Refnet Joint - RZQS71~140,RZQ100~140 Triple Refnet Joint - RZQ200~250 Condensing unit bracket - up to size 71, max weight 90kg of ODU Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU Condensate drip tray for use with Sky Air ODU - tray width 1100mm Condensing Unit Guard size 42-71 Condensing Unit Guard size 100-140 including RXYSQ

£29.00 £65.00 £81.00 £37.00 £46.00 £59.00 £296.00 £354.00

i) Accessories for fan coils and condensing units - refer to pair system pages

Price List 2015

39


Air curtains are the ideal solution to combat the issue of climate separation across retail outlets or office doorways. Features and benefits:

In conjunction with Biddle, Daikin ERQ heat pump air curtain solution combines the benefits of the Biddle air curtain technology with the benefits of Daikin ERQ heat pump inverter technology.

> Energy savings up to 72% compared with electric air curtains > Short payback times – less than 1.5 years > Wide capacity range for maximum application potential plus flexible control options > R-410A refrigerant, single and 3 phase > Wide operation range: -20~15.5°C in heating > Air curtain rectifier technology – deep penetrating airstream > Constant air velocity technology – all year round efficiency > European patent > 1.0, 1.5, 2.0 and 2.5 metre door widths > Door heights of up to 3.7 metres > C hoice of colour RAL9010:White or RAL9006:Grey

Using a combination of rectifier technology, air velocity and temperature control they deliver greater comfort to staff and customers alike, all year round, in all weathers. BIDDLE AIR CURTAINS & ERQ PAIRS ARE LISTED ON ECA – For product listing refer to: https://etl.decc.gov.uk/etl/site/etl.html

F = Free hanging model

C = Cassette model

R = Recessed model

Biddle Comfort air curtain range

Selection

3.7m

4m

Maximum door height (m)

SPLIT, SKY AIR HEAT PUMPS

CYVS/M/L - BC

3.2m 2.8m

2.7m

3m

1) U se the Door Height graph to determine the Air Curtain size relevant to your application

3.1m

2.35m

2.3m

2.0m

2.5m

2) W hen you know the size (S/M/L), refer to specific tables to select the model for your required door width

2m

1m

S

M

S

L

M

S

L

M

L

3) S elect Outdoor unit to pair door curtain, based on efficiency and power source

Installation condition Ideal for doors in a shopping centre or revolving door entrance

S

For more exposed doors with some direct wind, suitable for ground floor applications

For areas exposed to higher wind speeds i.e. open stairwell or balcony door at higher than ground level

Biddle Standard Air Curtain (Small) – Door height 2m to 2.7m

Maximum Door Width Mounting Height *2 Max / Min Model Name Type Heating Capacity Delta T Inlet = room temperature Power Input (50Hz) Fan only / Heating Dimensions Height Width Depth Weight Casing Colour Minimum requiring ceiling void Fan - Air Flow Rate Heating Sound Pressure Heating Refrigerant Type Piping Connections Liquid (OD) / Gas Power Supply

m m *=F speed 3 speed 3

speed 3 speed 3

kW k kW mm mm mm kg mm m3/sec dBA mm ph/V/Hz

Trade Unit Price

270 1,500 590 66

1.50 2.7 / 2.0 CYQS150DK80*BN *=C 9.00 15 0.35 / 0.35 270 1,500 821 83 white RAL9010 420 0.485 49 R-410A 9.52/16.0 1~/230/50

£2,908.00

£2,908.00

2.00 2.7 / 2.0 CYQS200DK100*BN *=C 11.60 15 0.46 / 0.46 270 2,000 821 102 white RAL9010 420 0.647 50 R-410A 9.52/16.0 1~/230/50

*=R

*=F

270 1,548 561 88

270 2,000 590 83

£3,065.00

£3,538.00

£3,538.00

2.50 2.7 / 2.0 CYQS250DK140*BN *=C 16.20 16 0.58 / 0.58 270 2,500 821 129 white RAL9010 420 0.808 51 R-410A 9.52/19.0 1~/230/50

*=R

*=F

270 2,048 561 108

270 2,500 590 107

£3,836.00

£3,972.00

£3,972.00

40

Residential, Commercial and Industrial

ERQ100AV1

ERQ100 AV1 ERQ125AV1 / AW1

270 2,548 561 137

£4,299.00

* 2: Mounting Height at base of Door Curtain Air Outlet. F = Free Hanging / C = Cassette / R = Recessed

Condensing Unit Selection for Small Door Curtain Standard Efficiency Improved Efficiency High Efficiency

*=R

ERQ125AV1 / AW1 ERQ140AV1 ERQ200AV1


SPLIT, SKY AIR HEAT PUMPS

M Biddle Standard Air Curtain (Medium) – Door height 2.3m to 3.2m Maximum Door Width

m

1.00

1.50

2.00

2.5

Mounting Height *2 Max / Min

m

3.2 / 2.3

3.2 / 2.3

3.2 / 2.3

3.2 / 2.3

Model Name

CYQM100DK80*BN

Type

*=F

Heating Capacity Delta T Power Input (50Hz) Dimensions

speed 3 Inlet = room temperature speed 3 Fan only / Heating Height Width Depth

Weight Casing Colour Minimum requiring ceiling void Fan - Air Flow Rate Heating Sound Pressure Heating Refrigerant Type Piping Connections Liquid (OD) / Gas Power Supply

speed 3 speed 3

kW k kW mm mm mm kg mm m3/sec dBA mm ph/V/Hz

Trade Unit Price

*=C

CYQM150DK80*BN

*=R

9.20 17 0.37 / 0.37 270 270 270 1,000 1,000 1,048 590 821 561 57 68 66 white RAL9010 420 0.446 50 R-410A 9.52/16.0 1~/230/50

*=F

*=C

*=R

11.00 14 0.56 / 0.56 270 270 270 1,500 1,500 1,548 590 821 561 73 88 93 white RAL9010 420 0.669 51 R-410A 9.52/16.0 1~/230/50

CYQM200DK100*BN *=F

*=C

CYQM250DK140*BN

*=R

13.40 13 0.75 / 0.75 270 270 270 2,000 2,000 2,048 590 821 561 94 111 117 white RAL9010 420 0.892 53 R-410A 9.52/16.0 1~/230/50

*=F

*=C

*=R

19.90 15 0.94 / 0.94 270 270 270 2,500 2,500 2,548 590 821 561 108 136 144 white RAL9010 420 1.115 54 R-410A 9.52/19.0 1~/230/50

£2,820.00 £2,820.00 £2,910.00 £3,360.00 £3,360.00 £3,515.00 £4,207.00 £4,207.00 £4,504.00 £4,816.00 £4,816.00 £5,137.00

* 2: Mounting Height at base of Door Curtain Air Outlet. F = Free Hanging / C = Cassette / R = Recessed

Condensing Unit Selection form Medium Door Curtain Standard Efficiency Improved Efficiency High Efficiency

L

ERQ100AV1

ERQ100AV1

ERQ125AV1 / AW1

ERQ100AV1 ERQ125AV1 / AW1 ERQ140AV1

ERQ200AW1 ERQ250AW1

Biddle Standard Air Curtain (Large) – Door height 2.5m to 3.7m

Maximum Door Width

m

1.00

1.50

2.00

2.5

Mounting Height *2 Max / Min

m

3.7 / 2.5

3.7 / 2.5

3.7 / 2.5

3.7 / 2.5

Model Name

CYQL100DK125*BN

Type Heating Capacity Delta T Power Input (50Hz) Dimensions

*=F speed 3 Inlet = room temperature speed 3 Fan only / Heating Height Width Depth

Weight Casing Colour Minimum requiring ceiling void Fan - Air Flow Rate Heating Sound Pressure Heating Refrigerant Type Piping Connections Liquid (OD) / Gas Power Supply

speed 3 speed 3

kW k kW mm mm mm kg mm m3/sec dBA mm ph/V/Hz

Trade Unit Price

*=C

CYQL150DK200*BN

*=R

15.60 15 0.75 / 0.75 370 370 370 1,000 1,000 1,048 774 1105 745 76 81 83 white RAL9010 520 0.861 53 R-410A 9.52/16.0 1~/230/50

*=F

*=C

*=R

23.30 15 1.13 / 1.13 370 370 370 1,500 1,500 1,548 774 1105 745 100 118 141 white RAL9010 520 1.292 54 R-410A 9.52/19.0 1~/230/50

CYQL200DK250*BN *=F

*=C

CYQL250DK250*BN

*=R

29.40 14 1.50 / 1.50 370 370 370 2,000 2,000 2,048 774 1105 745 126 151 155 white RAL9010 520 1.722 56 R-410A 9.52/22.0 1~/230/50

*=F

*=C

*=R

31.10 12 1.88 / 1.88 370 370 370 2,500 2,500 2,548 774 1105 745 157 190 196 white RAL9010 520 2.153 57 R-410A 9.52/22.0 1~/230/50

£3,217.00 £3,217.00 £3,226.00 £4,589.00 £4,589.00 £4,737.00 £5,697.00 £5,697.00 £5,993.00 £6,649.00 £6,649.00 £7,016.00

* 2: Mounting Height at base of Door Curtain Air Outlet. F = Free Hanging / C = Cassette / R = Recessed

Condensing Unit Selection for Large Door Curtain Standard Efficiency Improved Efficiency High Efficiency

ERQ125AV1 / AW1 ERQ140AV1 ERQ200AW1

ERQ200AW1 ERQ250AW1

ERQ250AW1

ERQ250AW1

ERQ Condensing Units Single Phase Dimensions

Height Width Depth

Weight Pipe Run Airflow Direction Trade Unit Price

mm mm mm kg mm

3 Phase

ERQ100AV1

ERQ125AV1

ERQ140AV1

ERQ125AW1

ERQ200AW1

ERQ250AW1

1135 900 320 120 55 Side blow

1135 900 320 120 55 Side blow

1135 900 320 120 55 Side blow

1680 635 765 159 55 Top blow

1680 930 765 187 55 Top blow

1680 930 765 240 55 Top blow

£1,533.00

£1,709.00

£2,049.00

£1,743.00

£3,271.00

£3,408.00

Accessories for all Door Curtains

Notes:

Accessory Ref

Description

Trade Price

BRC1E52A KRCS01-1 RTD-20/UK.FB2

Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock Remote room mounted temperature sensor Energy control PCB for Sky Air and VRV

£76.00 £46.00 £251.00

i) To calculate the price for a complete system, add together the prices for door curtain, ERQ and remote controller. 1 off

CYQL100DK125FBN

£4,021.00

1 off 1 off

ERQ125AV1 BRC1E52

£1,709.00 £76.00

Total

£5,806.00

Price List 2015

41


SPLIT, SKY AIR HEAT PUMPS

Central Ducted Solutions Even without the benefit of individual room control, the system can provide a flexible energy saving answer over traditional methods through the incorporation of inverter control and heat pump technology.

For central ducted distribution systems Daikin has the solution for providing cooling and heating of the air, enabling optimal comfort and efficiency.

The following pages include Packaged Heat Pump Rooftop systems, with optional economisers, to heat pump condensing units and connection kits for use with other manufacturers heating and cooling coils.

Air handling unit Liquid pipe

Liquid pipe

Gas pipe

Gas pipe

Field supply

EV kit

Control box

F1,F2 communication

DDC control (control w)

Air Cooled Heat Pump Inverter Condensing Unit Kit for DX Coil

Flexible control possibilities: Control w: Full external control from 3rd party temperature controller with volt free remote enable contact and linear variable capacity control output (3rd party DDC Controller required).

A range of R410a inverter condensing units for application with air handling units: > Inverter controlled heat pump units > Large capacity range (from 6.3 to 61.6 kW) > Ventilation and air conditioning in 1 solution > EKEXV-kit & control boxes are designed for outdoor installation and can be wall mounted > Per EKEXV-kit/control box, only 1 air handling unit coil can be connected > Outdoor unit operation range: -5°CDB ~ 43°CDB in cooling > For connectivity to VRV IV systems, please consult with your local Daikin representative Outdoor unit

Trade Unit Price

3ph

ERQ100AV1 ERQ125AV1 ERQ140AV1 ERQ125AW1 ERQ200AW1 ERQ250AW1

Trade Acc. Price

£1,533.00 £1,709.00 £2,049.00 £1,743.00 £3,271.00 £3,408.00

Control z (BRC1D52 required): Control via Daikin BRC1D52 remote controller and return air or remote sensor (KRCS01-1 optional). A volt free remote enable contact is required to confirm fan operation status. For re-circ applications only.

Control box

Expansion Valve Kit

control z control y, w control y, w

class 63

EKEQDCB EKEQFCBA EKEQMCBA EKEXV63 1ph

Control y: External control from 3rd party temperature controller with volt free remote enable contact. Fixed evaporating temperature selection, range: +3°C to +10°C.

P P P P P P

P P P P P P

£313.00

£361.00

class 80 EKEXV80

class 100

class 125

class 140

class 200

class 250

VRV only

P P P P -

P P P P P -

P P P P P P

P P P P P

P P

P P

VRV only

VRV only

£557.00

£70.00

£72.00

£79.00

£86.00

£99.00

£118.00

£132.00

£146.00

£160.00

For all AHU application selections with ERQ and VRV systems, please consult with a member of Daikin staff to ensure correct selection and AHU coil design parameters. Residential, Commercial and Industrial

class 500

P P P -

P: Pair Combination depending on air handling units coils volume

42

class 400

EKEXV100 EKEXV125 EKEXV140 EKEXV200 EKEXV250 EKEXV400 EKEXV500


SPLIT, SKY AIR HEAT PUMPS

ERAD-E

Large Condensing Units Large Condensing Unit (Standard Noise Level) ERAD120E-SS ERAD140E-SS ERAD170E-SS ERAD200E-SS ERAD220E-SS ERAD250E-SS ERAD310E-SS ERAD370E-SS ERAD440E-SS ERAD490E-SS Capacity EER Refrigerant Dimensions

Weight Electrical Details

Nominal Cooling

kW

121 2.89

144 2.82

165 2.87

196 3.01

219 2.97

Length Height Width

mm mm mm kg V Hz ph

2170 2.27 1290 1564

2170 2.27 1290 1587

3070 2.27 1290 1698

3070 2.27 1290 1739

3070 2.27 1290 1886

252 3.29

306 3.3

370 3.03

435 2.96

488 3.03

3070 2.27 1290 1928

3070 2220 2240 2355

3070 2220 2240 2559

3070 2220 2240 2642

3070 2220 2240 2677

POA

POA

POA

POA

POA

R134a

Power Supply

400 50 3

Trade Unit Price

POA

POA

POA

POA

POA

Large Condensing Unit (Low Noise Level) ERAD120E-SL ERAD140E-SL ERAD160E-SL ERAD190E-SL ERAD210E-SL ERAD240E-SL ERAD300E-SL ERAD350E-SL ERAD410E-SL ERAD460E-SL Capacity EER Refrigerant Dimensions

Weight Electrical Details

Nominal Cooling

kW

116 2.74

137 2.61

159 2.76

187 2.82

209 2.83

Length Height Width

mm mm mm kg V Hz ph

2170 2.27 1290 1712

2170 2.27 1290 1738

3070 2.27 1290 1851

3070 2.27 1290 1897

3070 2.27 1290 2046

243 3.11

295 3.22

352 2.88

409 2.72

462 2.76

3070 2.27 1290 2091

3070 2220 2240 2534

3070 2220 2240 2741

3070 2220 2240 2834

3070 2220 2240 2873

POA

POA

POA

POA

POA

R134a

Power Supply

Trade Unit Price

400 50 3 POA

POA

POA

POA

POA

Features: ERAD-E are a range of cooling only R134a condensing units for pair application with air handling units > Large capacity range 100 kW to 410 kW > Superior control logic using the new MicroTech III controller

> Single circuit units > Screw compressor with capacity control down to 25% > Available in both standard and low noise configurations Please contact your sales office for further information on these products

UATYQ

Rooftop Packaged Unit – Heat Pump UATYQ250CY1 UATYQ350CY1 UATYQ450CY1 UATYQ550CY1 UATYQ600CY1 UATYQ700CY1 Capacity Dimensions

Weight Air Flow Rate External Static Air Flow Rate Refrigerant Sound Power Level Drain size Electrical Details

Nominal Cooling Nominal Heating Height Width Depth Indoor Indoor Outdoor

kW kW mm mm mm kg m3/min Pa m3/min

27.34 24.91 1150 1638 2063 445 93 147 0

35.58 34.79 1028 2209 2113 580 122 147 0

44.72 41.79 1130 2209 2113 610 160 147 0

55.69 53.93 1048 2209 2670 830 190 206 0

66.82 61.69 1302 2209 2670 880 205 206 0

72.60 69.61 1302 2209 2670 1020 233 206 0

UATYPC10AY1

UATYPC12AY1

101.10 102.30 1974 2252 3180 1510 312

109.60 126.30 1974 2252 3180 1600 354

0

R410a Outdoor Power Supply

Running Current Starting Current Max Fuse Size

dBA mm V Hz Phase A A A

Trade Unit Price Economiser

82

83

0 R407C

83

87

90

90

80

80

41.6 144 50 £10,190.00

46.5 148 50 £10,904.00

74.2 175 , 215 125 £14,559.00

82.9 215x2 125 £15,816.00

25.4 (OD) 400 50 3ph 20.5 118 32 £5,027.00

26.4 93 40 £5,234.00

33.1 123 40 £8,612.00

39.4 137 50 £9,476.00

ECONO250AY1 ECONO350AY1 ECONO450AY1 ECONO550AY1 ECONO600AY1 ECONO700AY1

Trade Unit Price

£886.00

£931.00

£976.00

£1,024.00

£1,076.00

£1,129.00

Notes: i) Minimum Ambient operating conditions UATYQ250~700 UATYPC10~12

Cooling

Heating

0°C 20°C

-15°C -15°C

ii) Supplied with remote controller as standard

v) Please check stock & delivery period for all model sizes

iii) Economiser option is supplied as a kit for site assembly

vi) Standard delivery for all units does not include off-loading to kerbside

iv) Low ambient kit for models UATYPC available on request

vii) UATYQ250/350 can be off-loaded by fork-lift if there is one on site viii) All other units require crane or HIAB. Prices for HIAB available on request

Price List 2015

43


SPLIT, SKY AIR HEAT PUMPS


VRV

Daikin UK Price List 2015

VRV Indoor Units 46 VRV Fan Coil Units

46

Air Curtains

54

Hot Water Connection

56

Outdoor Condensing Units 59 VRV Condensing Units – Heat Recovery

59

VRV Condensing Units – Heat Pump

64

VRV Condensing Units – Heat Pump Mini

68

VRV Condensing Units – Water Cooled

71

VRV Condensing Units – Replacement VRV-Q

73

Accessories 81 VRV Unit Accessories Intelligent Controls

Scotland Region 0845 641 9330

Northern Region 0845 641 9340

Midlands Region 0845 641 9370

Western Region 0845 641 9320

North London 0845 641 9360

South London 0845 641 9355


FXFQ-A

VRV Fan Coil – Roundflow Cassette Indoor unit

VRV

Cooling capacity Heating capacity Power input - 50Hz Dimensions Weight Decoration panel

Decoration panel 2

Decoration panel 3

Fan-Air flow rate - 50Hz Sound power level Sound pressure level Refrigerant Piping connections Power supply Current - 50Hz

Nom. Nom. Cooling Heating Unit Unit Model Colour Dimensions Weight Model Colour Dimensions Weight Model Colour Dimensions Weight Cooling Heating Cooling

Nom. Nom. HxWxD

kW kW kW kW mm kg

HxWxD

mm kg

HxWxD

mm kg

HxWxD

mm kg m³/min m³/min dBA

High/Nom./Low High/Nom./Low High/Nom.

Cooling High/Nom./Low Heating High/Nom./Low Type Liquid/OD/Gas/OD/Drain Phase/Frequency/Voltage Maximum fuse amps (MFA)

FXFQ20A

FXFQ25A

FXFQ32A

FXFQ40A

FXFQ50A

FXFQ63A

2.2 2.5

2.8 3.2

3.6 4.0

4.5 5.0

5.6 6.3 0.053 0.053

7.1 8.0 0.061 0.061

0.038 0.038

12.5/10.6/8.8 12.5/10.6/8.8 49/31/29/28 31/29/28

mm Hz/V A

Trade Unit Price

FXFQ100A

9.0 11.2 10.0 12.5 0.092 0.115 0.092 0.115 246x840x840 24

FXFQ125A 14.0 16.0 0.186 0.186 288x840x840 26

204x840x840 20 21 Roundflow BYCQ140D (standard panel) Pure White (RAL 9010) 60x950x950 5.4 Roundflow with white louvres BYCQ140DW Pure White (RAL 9010) 60x950x950 5.4 Roundflow self cleaning BYCQ140DG Pure White (RAL 9010) 145x950x950 10.3 13.6/11.6/9.5 15.0/12.8/10.5 16.5/13.5/10.5 22.8/17.6/12.4 26.5/19.5/12.4 33.0/26.5/19.9 13.6/11.6/9.5 15.0/12.8/10.5 16.5/13.5/10.5 22.8/17.6/12.4 26.5/19.5/12.4 33.0/26.5/19.9 51/53/55/60/61/-

19

dBA dBA

FXFQ80A

33/31/29 33/31/29 R-410A

35/33/30 35/33/30

6.35/12.7/VP25 (O.D. 32 / I.D. 25)

38/34/30 38/34/30

43/37/30 43/37/30

45/41/36 45/41/36

9.52/15.9/VP25 (O.D. 32 / I.D. 25) 1~/50/ 220-240 16

£759.00

£774.00

£792.00

£855.00

£897.00

£946.00

£1,009.00

£1,095.00

£1,365.00

Notes: i) Cassette prices include standard decoration panel - self cleaning panel available as an accessory item ii) BYCQ140D7W1 = pure white panel with grey louvers , BYCQ140D7W1W = pure white standard panel with white louvers, BYCQ140D7GW1 = Pure white auto cleaning panel The BYCQ140D7W1W has white insulations. Be informed that formations of dirt on white insulation is visibly stronger & that it is consequently not advised to install the decoration panel in environments exposed to concentrations of dirt iii) For accessories please refer to pages 81 - 90

FXZQ-A

VRV Fan Coil – 600 Sq 4 Way Blow Cassette Indoor unit Cooling capacity Heating capacity Power input - 50Hz Dimensions Weight Decoration panel

Decoration panel 2

Decoration panel 3

Fan-Air flow rate - 50Hz Sound power level Sound pressure level Refrigerant Piping connections Power supply Current - 50Hz

Nom. Nom. Cooling Nom. Heating Nom. Unit HxWxD Unit Model Colour Dimensions H x W x D Weight Model Colour Dimensions H x W x D Weight Model Colour Dimensions H x W x D Weight Cooling High/Nom./Low Heating High/Nom./Low Cooling High/Nom. Cooling High/Nom./Low Heating High/Nom./Low Type Liquid/OD/Gas/OD/Drain Phase/Frequency/Voltage Maximum fuse amps (MFA)

kW kW kW kW mm kg

FXZQ15A

FXZQ20A

FXZQ25A

FXZQ32A

FXZQ40A

FXZQ50A

1.7 1.9

2.2 2.5 0.043 0.036

2.8 3.2

3.6 4.0 0.045 0.038

4.5 5.0 0.059 0.053

5.6 6.3 0.092 0.086

260x575x575 15.5

mm kg

mm kg

mm kg m³/min m³/min dBA dBA dBA

8.5/7/6.5 8.5/7/6.5

8.7/7.5/6.5 8.7/7.5/6.5 49/-

31.5/28/25.5 31.5/28/25.5

32/29.5/25.5 32/29.5/25.5

£721.00

£737.00

mm Hz/V A

Trade Unit Price

Notes: i) Cassette prices include Fully Flat decoration panel in fresh white. Other colour panels available on request. ii) Dimensions include control box iii) For accessories please refer to pages 81 - 90

46

Residential, Commercial and Industrial

16.5 Fully Flat in white BYFQ60CW (standard panel) White (N9.5) 46x620x620 2.8 Fully flat in white with silver BYFQ60CS White (N9.5) + Silver 46x620x620 2.8 Old style panel BYFQ60B3 White (RAL9010) 55x700x700 2.7 9/8/6.5 10/8.5/7 9/8/6.5 10/8.5/7 50/51/33/30/25.5 33.5/30/26 33/30/25.5 33.5/30/26 R-410A 6.35/12.7/VP20 (I.D. 20/O.D. 26) 1~/50/220-240 16 £752.00

£769.00

18.5

11.5/9.5/8 11.5/9.5/8 54/37/32/28 37/32/28

14.5/12.5/10 14.5/12.5/10 60/43/40/33 43/40/33

£825.00

£906.00


FXCQ-A

VRV Fan Coil – 2 Way Blow Cassette

Casing Dimensions Weight Decoration panel

Fan-Air flow rate - 50Hz Sound power level Sound pressure level Refrigerant Piping connections Air filter Power supply Current - 50Hz

Nom. Nom. Cooling Nom. Heating Nom. Material Unit HxWxD Unit Model Colour Dimensions H x W x D Weight Cooling High/Nom./Low Cooling Nom. Cooling High/Nom./Low Heating High/Nom./Low Type Liquid/OD/Gas/OD/Drain Type Phase/Frequency/Voltage Maximum fuse amps (MFA)

kW kW kW kW mm kg

mm kg m³/min dBA dBA dBA mm Hz/V A

Trade Unit Price

FXCQ20A

FXCQ25A

FXCQ32A

2.2 2.5 0.031 0.028

2.8 3.2

3.6 4.0

£854.00

£869.00

£878.00

FXCQ40A

FXCQ50A

FXCQ63A

FXCQ80A

FXCQ125A

4.5 5.6 7.1 9.0 14.0 5.0 6.3 8.0 10.0 16.0 0.039 0.041 0.059 0.063 0.090 0.149 0.035 0.037 0.056 0.060 0.086 0.146 Galvanised steel plate 305x775x620 305x990x620 305x1,445x620 19 22 25 33 38 BYBCQ40HW1 BYBCQ63HW1 BYBCQ125HW1 Fresh white (6.5Y 9.5/0.5) 55x1,070x700 55x1,285x700 55x1,740x700 10 11 13 10.5/9/7.5 11.5/9.5/8 12/10.5/8.5 15/13/10.5 16/14/11.5 26/22.5/18.5 32/27.5/22.5 32.0/30.0/28.0 34.0/31.0/29.0 34.0/32.0/30.0 36.0/33.0/31.0 37.0/35.0/31.0 39.0/37.0/32.0 42.0/38.0/33.0 46.0/42.0/38.0 32.0/30.0/28.0 34.0/31.0/29.0 34.0/32.0/30.0 36.0/33.0/31.0 37.0/35.0/31.0 39.0/37.0/32.0 42.0/38.0/33.0 46.0/42.0/38.0 R-410A 6.35/12.7/VP25 (O.D. 32 / I.D. 25) 9.52/15.9/VP25 (O.D. 32 / I.D. 25) Resin net with mold resistance 1~/50/220-240 16 £970.00

£1,061.00

£1,102.00

£1,265.00

£1,518.00

Notes: i) Cassette prices include decoration panel ii) For accessories please refer to pages 81 - 90

FXKQ-MA

VRV Fan Coil – 1 Way Blow Corner Cassette Indoor unit Cooling capacity Heating capacity Power input - 50Hz Dimensions Weight Decoration panel

Fan-Air flow rate - 50Hz Sound power level Sound pressure level Refrigerant Piping connections Power supply Current - 50Hz

Nom. Nom. Cooling Nom. Heating Nom. Unit HxWxD Unit Model Colour Dimensions H x W x D Weight Cooling High/Low Cooling Nom. Cooling High/Low Type Liquid/OD/Gas/OD/Drain Phase/Frequency/Voltage Maximum fuse amps (MFA)

Trade Unit Price

kW kW kW kW mm kg

FXKQ25MA

FXKQ32MA

FXKQ40MA

FXKQ63MA

2.8 3.2

3.6 4.0

4.5 5.0 0.076 0.056

7.10 8.00 0.105 0.085 215x1,310x710 34 BYK71FJW1

0.066 0.046 215x1,110x710 31 BYK45FJW1 White

mm kg m³/min dBA dBA

70x1,240x800 8.5 11/9

13/10

70x1,440x800 9.5 18/15

40.0/34.0

42.0/37.0

38.0/33.0 R-410AR-410A 6.35/12.7/VP25 (O.D. 32 / I.D. 25) 1~/50/ 220-240 15

mm Hz/V A £946.00

£956.00

9.52/15.9/VP25 (O.D. 32 / I.D. 25)

£1,045.00

£1,185.00

Notes: i) Cassette prices include decoration panel ii) For accessories please refer to pages 81 - 90

Price List 2015

47

VRV

Indoor unit Cooling capacity Heating capacity Power input - 50Hz


FXHQ-A

VRV Fan Coil – Ceiling Suspended Indoor unit

VRV

Cooling capacity Heating capacity Power input - 50Hz Casing Colour Dimensions Weight Fan-Air flow rate - 50Hz Sound power level Sound pressure level Refrigerant Piping connections Power supply Current - 50Hz

FXHQ32A Nom. Nom. Cooling Heating

Nom. Nom.

Unit HxWxD Unit Cooling High/Nom./Low Heating High/Nom./Low Cooling Nom. Cooling High/Nom./Low Heating High/Nom./Low Type Liquid/OD/Gas/OD/Drain Phase/Frequency/Voltage Maximum fuse amps (MFA)

kW kW kW kW mm kg m³/min m³/min dBA dBA dBA mm Hz/V A

Trade Unit Price

FXHQ63A

3.6 4.0 0.107 0.107 235x960x690 24 14.0/12.0/10.0 14.0/12.0/10.0 36.0/34.0/31.0 36.0/34.0/31.0 6.35/12.7/VP20 (I.D. 20/O.D. 26)

£906.00

FXHQ100A

7.1 11.2 8.0 12.5 0.111 0.237 0.111 0.237 Fresh White 235x1,270x690 235x1,590x690 33 39 20.0/17.0/14.0 29.5/24.0/19.0 20.0/17.0/14.0 29.5/24.0/19.0 37.0/35.0/34.0 44.0/37.0/34.0 37.0/35.0/34.0 44.0/37.0/34.0 R-410A 9.52/15.9/VP20 (I.D. 20/O.D. 26) 1~/50/220-240 16 £1,004.00

£1,246.00

Notes: i) For accessories please refer to pages 81 - 90

FXUQ-A

VRV Fan Coil – Under Ceiling Cassette Indoor unit Cooling capacity Heating capacity Power input - 50Hz Casing Colour Dimensions Weight Fan-Air flow rate - 50Hz Sound power level Sound pressure level Refrigerant Piping connections Power supply Current - 50Hz

Nom. Nom. Cooling Heating

Nom. Nom.

Unit HxWxD Unit Cooling High/Nom./Low Heating High/Nom./Low Cooling Nom. Cooling High/Nom./Low Heating High/Nom./Low Type Liquid/OD/Gas/OD/Drain Phase/Frequency/Voltage Maximum fuse amps (MFA)

kW kW kW kW mm kg m³/min m³/min dBA dBA dBA

FXUQ100A

8.0 9.0 0.090 0.073

11.2 12.5 0.200 0.179 Fresh White 198x950x950

26 22.5/19.5/16.0 22.5/19.5/16.0

Notes: i) For accessories please refer to pages 81 - 90

Residential, Commercial and Industrial

27 31.0/26.0/21.0 31.0/26.0/21.0 -

40.0/38.0/36.0 40.0/38.0/36.0

47.0/44.0/40.0 47.0/44.0/40.0 R-410A 9.52/15.9/I.D. 20/O.D. 26 1~/50/ 220-240 16

mm Hz/V A

Trade Unit Price

48

FXUQ71A

£1,254.00

£1,337.00


FXDQ-M9

VRV Fan Coil – Small Ducted Indoor unit

Casing Colour Dimensions Required ceiling void > Weight Fan-Air flow rate - 50Hz Sound power level Sound pressure level Refrigerant Piping connections Power supply Current - 50Hz

Nom. Nom. Cooling Heating

Nom. Nom.

Unit

HxWxD

Unit Cooling High/Low Heating High/Low Cooling Nom. Cooling High/Low Heating High/Low Type Liquid/OD/Gas/OD/Drain Phase/Frequency/Voltage Maximum fuse amps (MFA)

FXDQ20M9

FXDQ25M9

2.2 2.5

2.8 3.2

kW kW kW kW

0.050 0.050 Unpainted 230x502x652 250 17

mm mm kg m³/min m³/min dBA dBA dBA

6.7/5.2 6.7/5.2

VRV

Cooling capacity Heating capacity Power input - 50Hz

7.4/5.8 7.4/5.8 50 37/32 37/32 R-410A 6.35/12.7/I.D. 21.6, O.D. 27.2 1~/50/230 16

mm Hz/V A

Trade Unit Price

£579.00

£597.00

Notes: i) For accessories please refer to pages 81 - 90 ii) Fan coils supplied as standard with factory fitted filter

FXDQ-A

VRV Fan Coil – Slim Ducted Indoor unit Cooling capacity Heating capacity Power input - 50Hz Casing Colour Dimensions Required ceiling void > Weight Fan-Air flow rate - 50Hz Fan-External static pressure - 50Hz

Nom. Nom. Cooling Heating

Nom. Nom.

Unit

HxWxD

kW kW kW kW

FXDQ15A

FXDQ20A

FXDQ25A

FXDQ32A

FXDQ40A

FXDQ50A

FXDQ63A

1.7 1.9

2.2 2.5

2.8 3.2

3.6 4.0

4.5 5.0 0.078 0.075

5.6 6.3 0.099 0.096

7.1 8.0 0.110 0.107

0.071 0.068 Galvanised steel / Non painted

Unit Cooling High/Nom.

High/Nom./Low

mm mm kg m³/min Pa

Sound power level Sound pressure level Refrigerant Piping connections

Cooling Nom. Cooling High/Nom./Low Type Liquid/OD/Gas/OD/Drain

mm

Power supply Current - 50Hz

Phase/Frequency/Voltage Maximum fuse amps (MFA)

Hz/V A

Trade Unit Price

dBA dBA

200x750x620

200x950x620

200x1,150x620

26

29 16.5/14.5/13.0

240 22 7.5/7.0/6.4

8.0/7.2/6.4

10.5/9.5/8.5

12.5/11.0/10.0 44/15

51 33/31/27

52 34/32/28

53 35/33/29

30/10 50 32/31/27

R-410A 6.35/12.7/VP20 (I.D. 20/O.D. 26)

54 36/34/30 9.52/15.9/VP20 (I.D. 20/O.D. 26)

1~/50/ 220-240 16 £562.00

£579.00

£597.00

£605.00

£644.00

£670.00

£691.00

Notes: i) For accessories please refer to pages 81 - 90 ii) Fan coils supplied as standard with factory fitted filter

Price List 2015

49


NEW AVAILABLE SPRING 2015

FXSQ-A

VRV Fan Coil – Concealed Ceiling Unit (Medium Static)

Indoor Units Nominal Cooling Nominal Heating Air Flow Rate

Dimensions

High Low High Low Height x Width x Depth

Weight Electrical Details

Power Supply

Sound Level

Running Current Fuse Rating Sound Pressure

External Static Pressure

VRV

FXSQ15A FXSQ20A FXSQ25A FXSQ32A FXSQ40A FXSQ50A FXSQ63A FXSQ80A FXSQ100A FXSQ125A FXSQ140A

Piping Connections

High Low

Sound Power Liquid Gas

kW kW m3/sec m3/sec Pa Pa mm

1.7 1.9 0.145 0.1 150 30

2.2 2.8 2.5 3.2 0.15 0.15 0.15 0.15 150 150 30 30 245 x 550 x 800

kg Phase Hz V W amps dBA dBA dBA inches inches

23.5

23.5

23.5

41

41

29.5 25 54 1/4 1/2 £580.00

Trade Unit Price

3.6 4 0.158 0.15 150 30

4.5 5.6 5 6.3 0.25 0.25 0.25 0.25 150 150 30 30 245 x 700 x 800

7.1 9 8 10 0.35 0.38 0.35 0.38 150 150 30 40 245 x 1000 x 800

11.2 14 12.5 16 0.46 0.61 0.46 0.61 150 150 40 50 245 x 1400 x 800

24

28.5

35.5

36.5

46

47

41

45

92

95

121

157

214

tbc

30 25 54 1/4 1/2

30 25 54 1/4 1/2

31 26 55 1/4 1/2

35 29 60 1/4 1/2

29 1ph 50 230 95 5 35 29 60 1/4 1/2

16 18 0.65 0.65 150 50 245 x 1550 x 800 51

33 27 59 3/4 5/8

35 29 61 3/4 5/8

36 31 61 3/4 5/8

39 33 64 3/4 5/8

44 tbc tbc 3/4 5/8

£598.00

£614.00

£622.00

£662.00

£690.00

£712.00

£812.00

£900.00 £1,030.00 £1,133.00

Notes: i) For accessories please refer to pages 81 - 90 ii) Preliminary Data – May be subject to change

FXMQ-P7

VRV Fan Coil – High Static Ducted Indoor Units Capacity

Air Flow Rate External Static pressure

UK Total Cooling UK Sensible Cooling UK Heating Nominal Cooling Nominal Heating High Low High Low Height x Width x Depth

Dimensions Weight Electrical Details

Power Supply

Sound Level

Running Current Fuse Rating Sound Pressure

Piping Connections

High Low

Sound Power Liquid Gas

kW kW kW kW kW m3/sec m3/sec Pa Pa mm kg Phase Hz V amps amps dBA dBA dBA inches inches

Trade Unit Price

Notes: i) For accessories please refer to pages 81 - 90

50

Residential, Commercial and Industrial

FXMQ50P7

FXMQ63P7

FXMQ80P7

FXMQ100P7

FXMQ125P7

4.50 4.10 6.30 5.60 6.30 0.30 0.25 200.0 100.0

7.20 6.10 10.00 9.00 10.00 0.42 0.33 200.0 100.0

9.00 7.30 12.50 11.20 12.50 0.53 0.38 200.0 100.0

11.30 9.20 16.00 14.00 16.00 0.65 0.47 200.0 100.0

35

5.70 4.90 8.00 7.10 8.00 0.33 0.27 200.0 100.0 300 x 1000 x 700 35

46

46

1.4

1.4

2.3

2.9

41.0 37.0 61/1/4 1/2

42.0 38.0 64/3/8 5/8

35 1ph 50 230 1.7 5 43.0 39.0 67/3/8 5/8

43.0 39.0 65/3/8 5/8

44.0 40.0 70/3/8 5/8

£1,066.00

£1,117.00

£1,174.00

£1,301.00

£1,489.00

300 x 1400 x 700


FXMQ-MA

Indoor Units Capacity

Air Flow Rate External Static pressure Dimensions Weight Electrical Details

Sound Level

Piping Connections

UK Total Cooling UK Sensible Cooling UK Heating Nominal Cooling Nominal Heating High Low High Low Height x Width x Depth Power Supply

Running Current Fuse Rating Sound Pressure

High Low

Sound Power Liquid Gas

kW kW kW kW kW m3/sec m3/sec Pa Pa mm kg Phase Hz V amps amps dBA dBA dBA inches inches

FXMQ200MA

FXMQ250MA

18.00 14.90 25.00 22.40 25.00 0.97 0.83 221.0 132.0

22.50 18.50 31.50 28.00 31.50 1.20 1.03 270.0 147.0

VRV

VRV Fan Coil – High Static Ducted

470 x 1380 x 1100 137

137 1ph 50 230

6.5

7.2 13

Trade Unit Price

48.0 45.0 3/8 3/4

48.0 45.0 3/8 7/8

£2,601.00

£2,662.00

Notes: i) For accessories please refer to pages 81 - 90

FXAQ-P

VRV Fan Coil – Wall Mounted Indoor unit Cooling capacity Heating capacity Power input - 50Hz

Nom. Nom. Cooling Heating

Nom. Nom.

kW kW kW kW

Casing Colour Dimensions Weight Fan-Air flow rate - 50Hz Sound power level Sound pressure level Refrigerant Piping connections

Unit HxWxD Unit Cooling High/Low Cooling Nom. Cooling High/Low Type Liquid/OD/Gas/OD/Drain

mm

Power supply Current - 50Hz

Phase/Frequency/Voltage Maximum fuse amps (MFA)

Hz/V A

Trade Unit Price

mm kg m³/min dBA dBA

FXAQ15P

FXAQ20P

1.7 1.9 0.017 0.025

2.2 2.5 0.019 0.029

7.0/4.5 34.0/29.0

FXAQ25P

FXAQ32P

FXAQ40P

2.8 3.6 4.5 3.2 4.0 5.0 0.028 0.030 0.020 0.034 0.035 0.020 White (3.0Y8.5/0.5)White (3.0Y8.5/0.5) 290x795x238 11 7.5/4.5 8/5 8.5/5.5 12/9 35.0/29.0 36.0/29.0 37.5/29.0 39.0/34.0 R-410A 6.35/12.7/VP13 (I.D. 13/O.D. 18)

FXAQ50P

FXAQ63P

5.6 6.3 0.033 0.039

7.1 8.0 0.050 0.060

290x1,050x238 14 15/12

19/14

42.0/36.0

47.0/39.0 9.52/15.9/VP13 (I.D. 13/O.D. 18)

1~/50/220-240 16 £439.00

£452.00

£464.00

£469.00

£481.00

£507.00

£559.00

Notes: i) For accessories please refer to pages 81 - 90

Price List 2015

51


FXLQ-P

VRV Fan Coil – Floor Mounted Cased Indoor unit

VRV

Cooling capacity Heating capacity Power input - 50Hz Casing Colour Dimensions Weight Fan-Air flow rate - 50Hz Sound power level Sound pressure level Refrigerant Piping connections Power supply Current - 50Hz

Nom. Nom. Cooling Heating

kW kW kW kW

Nom. Nom.

Unit HxWxD Unit Cooling High/Low Cooling Nom. Cooling High/Low Type Liquid/OD/Gas/OD/Drain Phase/Frequency/Voltage Maximum fuse amps (MFA)

FXLQ20P

FXLQ25P

FXLQ32P

FXLQ40P

FXLQ50P

FXLQ63P

2.2 2.5

2.8 3.2

3.6 4.0

4.5 5.0

5.6 6.3

7.1 8.0

0.049 0.049

mm kg m³/min dBA dBA

600x1,000x232 27 7/6 35/32

mm Hz/V A

Trade Unit Price

£695.00

£706.00

0.090 0.090 Fresh white (RAL9010) / Dark grey (RAL7011) 600x1,140x232 32 8/6 11/8.5 38/33 R-410A 6.35/12.7/O.D. 21 1~/50/ 220-240 15 £720.00

0.110 0.110 600x1,420x232 38 14/11

16/12

39/34

40/35 9.52/15.9/O.D. 21

£746.00

£754.00

£799.00

Notes: i) For accessories please refer to pages 81 - 90

NEW AVAILABLE SUMMER 2015

FXNQ-A

VRV Fan Coil – Vertical Chassis Unit

Indoor Units Capacity Air Flow Rate Dimensions Weight Electrical Details

Sound Level Piping Connections

Nominal Cooling Nominal Heating High Low Height x Width x Depth Power Supply

Running Current Fuse Rating Sound Pressure

High Low

Liquid Gas

kW kW m3/sec m3/sec mm kg Phase Hz V amps amps dBA dBA inches inches

Trade Unit Price

FXNQ20A

FXNQ25A

FXNQ32A

FXNQ40A

FXNQ50A

FXNQ63A

2.2 2.5 0.13 10.6

2.8 3.2 0.13 10.6 620 x 750 x 200 22

3.6 4 0.13 10.6

4.5 5 0.175 0.14

5.6 6.3 0.21 0.166

22

26

26

7.1 8 0.275 0.216 620 x 1350 x 200 29

tbc

tbc

tbc

22

620 x 950 x 200 1ph 50 230

tbc

tbc

tbc 5

tbc tbc 1/4 1/2

tbc tbc 1/4 1/2

tbc tbc 1/4 1/2

tbc tbc 1/4 1/2

tbc tbc 1/4 1/2

tbc tbc 3/8 5/8

£649.00

£659.00

£673.00

£697.00

£704.00

£748.00

Increased static pressure – up to 44Pa

Notes: i) For accessories please refer to pages 81 - 90 ii) Preliminary Data – May be subject to change

52

Residential, Commercial and Industrial


FXNQ-P

VRV Fan Coil – Floor Mounted Chassis

Indoor Units Capacity

Air Flow Rate Dimensions Weight Electrical Details

Sound Level

Piping Connections

UK Total Cooling UK Sensible Cooling UK Heating Nominal Cooling Nominal Heating High Low Height x Width x Depth Power Supply

Running Current Fuse Rating Sound Pressure

High Low

Sound Power Liquid Gas

kW kW kW kW kW m3/sec m3/sec mm kg Phase Hz V amps amps dBA dBA dBA inches inches

Trade Unit Price

FXNQ20P

FXNQ25P

FXNQ32P

FXNQ40P

FXNQ50P

FXNQ63P

1.80 1.50 2.50 2.20 2.50 0.12 0.10

2.30 1.80 3.20 2.80 3.20 0.12 0.10

2.90 2.20 4.00 3.60 4.00 0.13 0.10

3.60 2.70 5.00 4.50 5.00 0.18 0.14

4.50 3.40 6.30 5.60 6.30 0.23 0.18

5.70 4.20 8.00 7.10 8.00 0.27 0.20

19

23

23

27

27

0.5

0.5

0.5

610 x 930 x 220 19

610 x 1070 x 220

VRV

AVAILABLE UP TO SUMMER 2015

610 x 1350 x 220

1ph 50 230 0.2

0.2

0.5 5

35.0 32.0 1/4 1/2

35.0 32.0 1/4 1/2

35.0 32.0 1/4 1/2

38.0 33.0 1/4 1/2

39.0 34.0 1/4 1/2

40.0 35.0 3/8 5/8

£618.00

£628.00

£641.00

£664.00

£670.00

£712.00

Notes: i) For accessories please refer to pages 81 - 90

UK.FXDQ AVAILABLE UP TO SUMMER 2015

VRV Fan Coil – Low Level Wall Mounted Chassis (Medium Static)

Indoor Units Capacity

Air Flow Rate

External Static Pressure Dimensions Weight Electrical Details

Sound Level

Piping Connections

UK.FXDQ15A UK Total Cooling UK Sensible Cooling UK Heating Nominal Cooling Nominal Heating High Nom Low High Low Height Power Supply

Running Current Fuse Rating Sound Pressure

Sound Power Liquid Gas

Trade Unit Price

Hi Hi High Low

kW kW kW kW kW m3/sec m3/sec m3/sec Pa Pa mm kg Phase Hz V amps amps dBA dBA dBA dBA inches inches

1.40 1.30 1.70 1.70 1.70 0.13 0.12 0.11 30.0 10.0

UK.FXDQ20A

UK.FXDQ25A

UK.FXDQ32A

22

1.80 2.30 1.60 1.90 2.50 3.20 2.20 2.80 2.50 3.20 0.13 0.13 0.12 0.12 0.11 0.11 30.0 30.0 10.0 10.0 620 x 700 x 200 22 22

2.90 2.20 4.00 3.60 4.00 0.13 0.12 0.11 30.0 10.0

0.3

0.3

0.3

32.0 31.0 29.0 1/4 1/2

33.0 31.0 29.0 1/4 1/2

33.0 31.0 29.0 1/4 1/2

22 1ph 50 230 0.3 5 33.0 31.0 29.0 1/4 1/2

£793.00

£810.00

£828.00

£836.00

UK.FXDQ40A

UK.FXDQ50A

3.60 4.50 2.80 3.50 5.00 6.30 4.50 5.60 5.00 6.30 0.18 0.21 0.16 0.18 0.14 0.17 44.0 44.0 15.0 15.0 620 x 950 x 200 26 26

UK.FXDQ63A 5.70 4.30 8.00 7.10 8.00 0.28 0.24 0.22 44.0 15.0 620 x 1150 x 200 29

0.4

0.4

0.5

34.0 32.0 28.0 1/4 1/2

35.0 33.0 29.0 1/4 1/2

36.0 34.0 30.0 3/8 5/8

£875.00

£901.00

£922.00

Notes: i) For accessories please refer to pages 81 - 90

Price List 2015

53


CYVS/M/L - DK - F/C/R

In conjunction with Biddle, Daikin VRV IV heat recovery air curtain solution combines the benefits of the Biddle air curtain technology with the benefits of Daikin VRV IV heat recovery. Using a combination of rectifier technology, air velocity and temperature control they deliver greater comfort to staff and customers alike, all year round, in all weathers. Easy and fast installation of these systems not only reduces costs but makes expensive water systems, boilers and gas connections redundant. Integrating a Biddle air curtain with Daikin VRV also eliminates the need to install multiple outdoor units thereby reducing installation time and costs further. This combination enables Daikin to offer its customers the ultimate environmentally conscious TOTAL SOLUTION PACKAGE comprising cooling, heating, outdoor-indoor climate separation and fresh air ventilation. Some air curtains may be ECA compliant please see ECA website for details www.daikin.co.uk/ECA

Features and benefits: > > > > > > > > >

rovides virtually free air curtain heating via recovered heat from indoor units in cooling mode P Connection to the high COP heat recovery system enables COP’s of up to 4.36 Short payback times – less than 3 years Air curtain rectifier technology – deeply penetrating airstream Constant air velocity technology – all year round efficiency European patent 1.0, 1.5, 2.0 and 2.5 metre door widths Door heights of up to 3.7 metres Choice of colour RAL9010:White or RAL9006:Grey

F = Free hanging model

C = Cassette model

R = Recessed model

Biddle Comfort air curtain range Selection

3.7m

4m

Maximum door height (m)

VRV

Air curtains are the ideal solution to combat the issue of climate separation across retail outlets or office doorways.

3.2m 3m

2.8m

2.7m

3.1m

2.35m 2.0m

2.3m

2.5m

2m

2) W hen you know the size (S/M/L), refer to specific tables to select the model for your required door width

1m

S

M

L

S

M

L

S

M

L

Installation condition Ideal for doors in a shopping centre or revolving door entrance

54

1) U se the Door Height graph to determine the Air Curtain size relevant to your application

For more exposed doors with some direct wind, suitable for ground floor applications

Residential, Commercial and Industrial

For areas exposed to higher wind speeds i.e. open stairwell or balcony door at higher than ground level


CYVS/M/L - DK - F/C/R Small air curtains:

Maximum Door Width

1.0

1.5

2.0

Mounting Height *2 Model name

CYVS100DK80*BC

Type Heating capacity Delta T Power input (50Hz) Dimensions

2.5

2.7 / 2.0

speed 3 Inlet = room temperature speed 3 Fan only / Heating Height Width Depth

Weight

kW kW kW mm mm mm kg

Casing Colour Minimum requiring ceiling void

*=F

*=C

270 1,000 590

7.40 15 0.23/0.23 270 1,000 891 59

56

mm

Fan - Air flow rate

Heating

speed 3

m3/sec

Sound pressure Refrigerant

Heating Type

speed 3

dBA

Piping connections Power supply

Liquid (OD) / Gas

mm ph/V/Hz

*= R

CYVS150DK80*BC *=F

*=C

270 1,048 561

270 1,500 590

9.00 15 0.35/0.35 270 1,500 821

61

66

83

CYVS200DK100*BC

*= R

*=F

*=C

270 1,548 561

270 2,000 590

11.60 15 0.46/0.46 270 2,000 821

88

83

102

*= R

CYVS250DK140*BC *=F

*=C

*= R

270 2,048 561

270 2,500 590

16.20 16 0.58/0.58 270 2,500 821

270 2,548 561

108

107

129

137

white RAL9010 420

white RAL9010 420

white RAL9010 420

white RAL9010 420

0.323

0.485

0.647

0.808

47 R-410A

49 R-410A

50 R-410A

51 R-410A

9.52/16.0 1~/230/50

9.52/16.0 1~/230/50

9.52/16.0 1~/230/50

9.52/19.0 1~/230/50

£2,486.00 £2,456.00 £2,560.00 £3,167.00 £3,136.00 £3,311.00 £3,827.00 £3,798.00 £4,103.00 £4,270.00 £4,240.00 £4,575.00

Trade Unit Price

M Medium air curtains: Maximum Door Width

1.0

1.5

2.0

Mounting Height *2

2.5

3.2 / 2.3

Model name

CYVM100DK80*BC

Type

*=F

Heating capacity

*=C

*= R

CYVM150DK80*BC *=F

*=C

CYVM200DK100*BC

*= R

*=F

*=C

*= R

CYVM250DK140*BC *=F

*=C

speed 3

kW

9.20

11.00

13.40

19.90

Delta T Power input (50Hz)

Inlet = room temperature speed 3 Fan only / Heating

kW kW

17 0.37/0.37

14 0.56/0.56

13 0.75/0.75

15 0.94/0.94

Dimensions

Height Width Depth

mm mm mm

Weight Casing Colour Minimum requiring ceiling void

kg

57

mm

Fan - Air flow rate

Heating

speed 3

m3/sec

Sound pressure Refrigerant

Heating Type

speed 3

dBA

Piping connections Power supply

Liquid (OD) / Gas

mm ph/V/Hz

270 1,000 891

270 1,048 561

68 66 white RAL9010 420

270 1,500 590 73

270 1,500 821

270 1,548 561

88 93 white RAL9010 420

270 2,000 590 94

270 2,000 821

270 2,048 561

111 117 white RAL9010 420

270 2,500 590 108

270 2,500 821

270 2,548 561

136 144 white RAL9010 420

0.446

0.669

0.892

1.115

50 R-410A

51 R-410A

53 R-410A

54 R-410A

9.52/16.0 1~/230/50

9.52/16.0 1~/230/50

9.52/16.0 1~/230/50

9.52/19.0 1~/230/50

£2,844.00 £2,813.00 £2,919.00 £3,644.00 £3,613.00 £3,773.00 £4,514.00 £4,484.00 £4,788.00 £5,137.00 £5,108.00 £5,436.00

Trade Unit Price

L

270 1,000 590

*= R

Large air curtains:

Maximum Door Width

1.0

1.5

2.0

Mounting Height *2

2.5

3.7 / 2.5

Model name

CYVM100DK80*BC

Type

*=F

Heating capacity Delta T Power input (50Hz)

speed 3 Inlet = room temperature speed 3 Fan only / Heating

kW kW kW

Dimensions

Height Width Depth

mm mm mm

Weight Casing Colour Minimum requiring ceiling void

kg mm

Fan - Air flow rate

Heating

speed 3

m3/sec

Sound pressure Refrigerant

Heating Type

speed 3

dBA

Piping connections Power supply

Liquid (OD) / Gas

mm ph/V/Hz

*=C

*= R

CYVM150DK80*BC *=F

9.20 17 0.37/0.37 270 1,000 590 57

270 1,000 891

*=C

*= R

CYVM200DK100*BC *=F

*=C

11.00 14 0.56/0.56 270 1,048 561

68 66 white RAL9010 420

270 1,500 590 73

270 1,500 821

*= R

CYVM250DK140*BC *=F

13.40 13 0.75/0.75 270 1,548 561

88 93 white RAL9010 420

270 2,000 590 94

270 2,000 821

*=C

*= R

19.90 15 0.94/0.94 270 2,048 561

111 117 white RAL9010 420

270 2,500 590 108

270 2,500 821

270 2,548 561

136 144 white RAL9010 420

0.446

0.669

0.892

1.115

50 R-410A

51 R-410A

53 R-410A

54 R-410A

9.52/16.0 1~/230/50

9.52/16.0 1~/230/50

9.52/16.0 1~/230/50

9.52/19.0 1~/230/50

£3,623.00 £3,585.00 £3,696.00 £4,820.00 £4,783.00 £4,932.00 £5,935.00 £5,897.00 £6,193.00 £6,892.00 £6,855.00 £7,219.00

Trade Unit Price

Accessories:

Notes:

Accessory Ref

Description

Trade Price

BRC1E52A KRCS01-1 RTD-20/UK.FB2

Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock Remote room mounted temperature sensor Energy control PCB for Sky Air and VRV

£76.00 £46.00 POA

i) Biddle Remote Controller and connection cable included for Fan Speed Control ii) If RTD-20 Connected in Air Curtain mode the Biddle Remote Controller is NOT connected as Fan speed is managed by RTD-20 iii) Code “BC” is for white finish. Aluminium finish “SC”available on request

Price List 2015

55

VRV

S


HXHD-A / HXY-A

Hot water generation – VRV heat recovery systems

VRV

Producing hot water from a heat recovery VRV system is one of the most energy efficient means of providing hot water within a building. We can provide high and low temperature hot water for bathrooms, toilet wash basins, underfloor heating, radiators and even provide heated water for air handling unit applications. HXHD-A (High temperature)

Using waste heat to provide hot water means you can provide an additional service to your building from the heat recovery VRV system at very low cost.

Features and benefits: For both low temperature and high temperature > Uses heat pump technology to produce hot water efficiently, providing up to 17% savings compared to a gas boiler > Saves time on system design as all water-side components are fully integrated with direct control over leaving water temperature > Requires no gas connection or oil tank

HXY-A (Low temperature)

For low temperature > Highly efficient space heating/cooling > Leaving water temperature range from 5°C to 45°C without electric heater > Super wide operating range for cold/hot water production from -20 to +43°C ambient outdoor temperature > Saves space with contemporary wall hung design For high temperature > Possibility to connect thermal solar collectors to the domestic hot water tank > Leaving water temperature range from 25 to 80°C without electric heater > Various control possibilities with weather dependant set point or thermostat control

45°C - 75°C Domestic hot water VRV indoor units VRV heat recovery with connection to heating only hydrobox (REYQ-T)

EKHTSU-AC

EKHWP-B

25°C - 75°C

Air handling unit

BS-Box

45°C - 75°C

Low temp. radiator

BS-Box Heating only hydrobox for VRV 25°C - 35°C

Liquid pipe Gas pipe Discharge gas pipe Hot/cold water

BS-Box

Hot/cold water

56

Residential, Commercial and Industrial

HXY-A Low temperature hydrobox

Under floor heating


HXHD-A / HXY-A

Hot water generation – VRV heat recovery systems Indoor unit

HXHD125A

HXY080A

High Temperature

Dimensions Weight Sound pressure level Operation range

Nom. Nom. Colour Material Unit Unit Nom. Night quiet mode Heating Domestic hot water

Refrigerant Refrigerant circuit Water circuit Power supply Current

kW kW

14.0 Metallic grey

8 9

12.5 14 White

Precoated sheet metal H xW xD

Level 1 Ambient Water side Ambient Water side

Type Gas side diameter Liquid side diameter Piping connections diameter Heating water system Water volume Phase/Frequency/Voltage Recommended fuses

Trade Unit Price

Min.~Max. Min.~Max. Min.~Max. Min.~Max.

Min.~Max.

mm kg dBA dBA °C °C °CDB °C mm mm inch l Hz/V A

705x600x695 92 42 (1) / 43 (2) 38 (1) -20~20 / 24 (3) 25~80 -20~43 45~75 R-134a 12.7 9.52 G 1” (female) 20~200 1~/50/220-240 20 £2,713.00

890x480x344 44

VRV

Cooling Capacity Heating capacity Casing

HXY125A Low Temperature

-20~24 25~45 R-410A 15.9 9.5 G 1” 1/4(female) 1~/50/220-240 6~16 £1,461.00

£2,050.00

(1) Sound levels are measured at: EW 55°C; LW 65°C (2) Sound levels are measured at: EW 70°C; LW 80°C (3) Field setting

Notes: i) Hydroboxes are connectable to the following outdoor series only: Air Cooled Heat Recovery REYQ-T (see page 59) ii) Hydroboxes are inclusive of integral expansion vessel, and pump

EKHTSU

HT Water Tank Domestic Unvented Hot Water Tank Water Volume Max Water Temperature Height Width Depth Empty Weight Colour Material Inside Tank Material Outside Casing Piping Connections Water inlet H/E (Diameter) Water outlet H/E Cold Water in Hot water out Trade Unit Price

EKHTSU200AC l °C mm mm mm kg

inch inch inch inch

EKHTSU260AC

Unvented System (Includes EKUHWHT unvented Kit as shown below) 200 260 75 1335 1610 600 600 695 695 81 89 Metallic grey Stainless Steel Precoated sheet metal 3/4 " 3/4 " 3/4 " 3/4 " £1,121.00

£1,269.00

Accessories:

Notes:

Accessories For Unvented Systems

Trade Unit Price

EKUHWHT

Included with EKHTSU*AC £277.00

EKFMAHTB

Includes: Combined Pressure Reducing Valve, Non Return Valve, Strainer, Expansion Relief Valve, Expansion Vessel, Tundish Option for stand alone tank (ie not mounted on top of hydrobox)

i) Hydroboxes are connectable to the following outdoor series only: Air Cooled Heat Recovery REYQ-T (see page 59) ii) Hydroboxes are inclusive of integral expansion vessel and pump

Price List 2015

57


HXY-A

Hot water generation – VRV heat pump systems

VRV

Producing hot water from a heat pump system provides extremely low cost heating and cooling of water. Temperatures between 5°C to 45°C can be achieved allowing water temperature control for multiple applications without the need for a separate system. HXY-A

Features and benefits: > H ighly efficient space heating/cooling > Air to water connection to VRV for applications such as underfloor, AHU, low temperature radiators > Leaving water temperature range from 5°C to 45°C without electric heater > Super wide operating range for cold/hot water production from -20 to +43°C ambient outdoor temperature

> S aves time on system design as all water-side components are fully integrated with direct control over leaving water temperature > Saves space with contemporary wall hung design > Requires no gas connection or oil tank

Liquid pipe Gas pipe Hot/cold water

VRV indoor units

Air handling unit

VRV IV heat pump

Low temp. radiator

HXY-A Low temperature hydrobox

Under floor heating

Indoor unit Cooling capacity Heating capacity Casing Dimensions Weight Sound pressure level Operation range Refrigerant Refrigerant circuit Water circuit Power supply Recommended fuses

Nom. Nom. Colour Material Unit Unit Nom. Heating

kW kW

HxWxD

Ambient Water side

Min.~Max. Min.~Max.

Type Gas side diameter Liquid side diameter Piping connections diameter Phase/Frequency/Voltage

Trade Unit Price

58

Residential, Commercial and Industrial

HXY080A

HXY125A

8 9

12.5 14 White Precoated sheet metal 890x480x344 44 -20~24 25~45 R-410A 15.9 9.5 G 1”1/4 (female) 1~/50/220-240 6~16

mm kg dBA °C °C mm mm inch Hz/V A £1,461.00

£2,050.00


The VRV Total Solution

VRV

Many buildings today typically operate quite separate systems for heating, cooling, refrigeration and hot water. As a result, a huge amount of energy is wasted. To provide a much more efficient alternative, VRV technology has been developed into a total solution for heating, cooling, refrigeration and ventilation.

The VRV total solution Air conditioning, refrigeration and cooling IT servers can generate masses of waste heat that can be reused to heat and ventilate other areas of the building or to provide hot water for wash rooms, at a much reduced cost. By understanding the whole building’s heating and cooling needs at the outset, an integrated climate control solution can be delivered that offers much higher energy efficiency levels, thus reducing the carbon impact of a building. This means that all internal and external conditions must be taken into account in the design of the climate control system.

REYQ-T (8 to 12 HP)

VRV IV Condensing Units – Heat Recovery Outdoor Units

8 HP Single

10 HP Single

REYQ8T

REYQ10T

kW kW mm kg m3/sec Phase amps amps amps

22.40 22.40 1685 x 930 x 765 198 2.70

28.00 28.00 1685 x 930 x 765 205 2.92

8.9

11.8

20

25

kg kg dBA dBA m m inches inches inches

data book

data book

58 78

58 79

Capacity Index Limit Maximum Number of Connected Indoor Units

3/4 3/8 5/8 100 ~ 260 64

7/8 3/8 3/4 125 ~ 325 64

Trade Condensing Unit Price

£4,984.00

£5,475.00

Capacity Dimensions Weight Fan Electrical Details

Refrigerant Circuit

Sound Pressure Sound Power Piping Limits Piping Connections Systems

Nominal Cooling Nominal Heating Height x Width x Depth Air Flow Rate Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge

Maximum Total Length Maximum Actual Length Liquid Gas Discharge

10 HP Multi REMQ5T

12 HP Single REMQ5T

REYQ12T

28.00 28.00 1685 x 930 x 765 1685 x 930 x 765 198 198 2.70 2.70 3ph / 50 Hz / 380~415V 5.3 4 20 20 R410A data book data book 58 58 78 78 1000 165 7/8 3/8 3/4 125 ~ 325 64 £6,840.00

33.50 33.50 1685 x 930 x 765 205 3.08 15.3 25 data book 61 81

1 1/8 1/2 3/4 150 ~ 390 64 £6,639.00

Price List 2015

59


REYQ-T (13 to 16 HP)

VRV IV Condensing Units – Heat Recovery Outdoor Units

13 HP Multi REYQ8T

VRV

Capacity Dimensions Weight Fan Electrical Details

Refrigerant Circuit

Sound Pressure Sound Power Piping Limits Piping Connections Systems

Nominal Cooling Nominal Heating Height x Width x Depth Air Flow Rate Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge

Maximum Total Length Maximum Actual Length Liquid Gas Discharge

REMQ5T

kW kW mm kg m3/sec Phase amps amps amps

36.40 33.50 1685 x 930 x 765 1685 x 930 x 765 198 198 2.70 2.70

kg kg dBA dBA m m inches inches inches

data book

8.9

5.3

20

20

58 78

58 78

1 1/8 1/2 3/4 162.5 ~ 422.5 64

Capacity Index Limit Maximum Number of Connected Indoor Units Trade Condensing Unit Price

£8,404.00

14 HP Single

16 HP Single

REYQ14T

REYQ16T

40.00 45.00 40.00 45.00 1685 x 1240 x 765 1685 x 1240 x 765 319 319 3.72 4.33 3ph / 50 Hz / 380~415V 17.4 21.1 4 32 40 R410A data book data book data book 61 64 81 86 1000 165 1 1/8 1 1/8 1/2 1/2 7/8 7/8 175 ~ 455 200 ~ 520 64 64 £7,827.00

16 HP Multi REYQ8T

REYQ8T

45.00 45.00 1685 x 930 x 765 1685 x 930 x 765 198 198 2.70 2.70 8.9 20

20 data book

58 78

58 78

1 1/8 1/2 7/8 200 ~ 520 64

£9,224.00

£9,968.00

REYQ-T (18 to 20 HP)

VRV IV Condensing Units – Heat Recovery Outdoor Units

18 HP Single REYQ18T

Capacity Dimensions Weight Fan Electrical Details

Refrigerant Circuit

Sound Pressure Sound Power Piping Limits Piping Connections Systems

Nominal Cooling Nominal Heating Height x Width x Depth Air Flow Rate Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge

Maximum Total Length Maximum Actual Length Liquid Gas Discharge

kW kW mm kg m3/sec Phase amps amps amps

50.00 51.00 1685 x 1240 x 765 329 4.18

kg kg dBA dBA m m inches inches inches

data book

Capacity Index Limit Maximum Number of Connected Indoor Units Trade Condensing Unit Price

60

Residential, Commercial and Industrial

24.6 40

65 86

1 1/8 5/8 7/8 225 ~ 450 64 £10,459.00

18 HP Multi REYQ8T

REYQ10T

20 HP Single REYQ20T

51.00 56.00 51.00 56.00 1685 x 930 x 765 1685 x 930 x 765 1685 x 1240 x 765 198 205 329 2.70 2.92 4.35 3ph / 50 Hz / 380~415V 8.9 11.8 31.1 4 20 25 50 R410A data book data book data book data book 58 58 66 78 79 88 1000 165 3/4 1 1/8 3/8 5/8 5/8 1 1/8 100 ~ 260 250 ~ 650 64 64 £10,459.00

£11,395.00

20 HP Multi REYQ10T

REYQ10T

56.00 56.00 1685 x 930 x 765 1685 x 930 x 765 205 205 2.92 2.92 11.8 25

25 data book

58 79

58 79

1 1/8 5/8 1 1/8 250 ~ 650 64 £10,950.00


REYQ-T (22 to 28 HP)

VRV IV Condensing Units – Heat Recovery 22 HP Multi REYQ10T Capacity Dimensions Weight Air Flow Rate Electrical Details

Refrigerant Circuit

Sound Pressure Sound Power Piping Limits Piping Connections Systems

Nominal Cooling Nominal Heating Height x Width x Depth

Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge

Maximum Total Length Maximum Actual Length Liquid Gas Discharge

kW kW mm kg m3/sec Phase amps amps amps kg kg dBA dBA m m inches inches inches

24 HP Multi

REYQ12T

61.50 61.50 1685 x 930 1685 x 930 x 765 x 765 205 205 2.92 3.08 11.8

15.3

25

25 data book

58 79

61 81

1 1/8 5/8 1 1/8 275 ~ 715 64

Capacity Index Limit Maximum Number of Connected Indoor Units Trade Condensing Unit Price

£12,114.00

REYQ8T

REYQ16T

26 HP Multi REYQ12T

REYQ14T

67.40 73.50 67.40 73.50 1685 x 930 1685 x 1240 1685 x 930 1685 x 1240 x 765 x 765 x 765 x 765 210 305 205 319 2.70 4.33 3.08 3.72 3ph / 50 Hz / 380~415V 8.9 21.1 15.3 17.4 4 20 40 25 32 R410A data book data book data book 58 64 61 61 78 86 81 81 1000 165 1 3/8 1 3/8 3/4 3/4 1 1/8 1 1/8 300 ~ 780 325 ~ 845 64 64 £14,208.00

28 HP Multi REYQ12T

REYQ16T

78.50 78.50 1685 x 930 1685 x 1240 x 765 x 765 205 319 3.08 4.33 15.3

21.1

25

40 data book

61 81

64 86

1 3/8 3/4 1 1/8 350 ~ 910 64

£14,466.00

£15,863.00

REYQ-T (30 to 36 HP)

VRV IV Condensing Units – Heat Recovery Outdoor Units

30 HP Multi REYQ12T

Capacity Dimensions Weight Fan Electrical Details

Refrigerant Circuit

Sound Pressure Sound Power Piping Limits Piping Connections Systems

Nominal Cooling Nominal Heating Height x Width x Depth

Air Flow Rate Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge

Maximum Total Length Maximum Actual Length Liquid Gas Discharge

Capacity Index Limit Maximum Number of Connected Indoor Units Trade Condensing Unit Price

kW kW mm kg m3/sec Phase amps amps amps kg kg dBA dBA m m inches inches inches

32 HP Multi

REYQ18T

83.50 83.50 1685 x 930 1685 x 1240 x 765 x 765 205 329 3.08 4.18 15.3

24.6

25

40 data book

61 81

65 86

1 3/8 3/4 1 1/8 375 ~ 975 64 £17,163.00

REYQ16T

REYQ16T

34 HP Multi REYQ16T

REYQ18T

90.00 95.00 90.00 95.00 1685 x 1240 1685 x 1240 1685 x 1240 1685 x 1240 x 765 x 765 x 765 x 765 319 319 319 329 4.33 4.33 4.33 4.18 3ph / 50 Hz / 380~415V 21.1 21.1 24.6 4 40 40 40 40 R410A data book data book data book 64 64 64 65 86 86 86 86 1000 165 1 3/8 1 3/8 3/4 3/4 1 1/8 1 1/8 400 ~ 1040 425 ~ 1105 64 64 £18,448.00

£19,748.00

36 HP Multi REYQ16T

REYQ20T

101.00 101.00 1685 x 1240 1685 x 1240 x 765 x 765 319 329 4.33 4.35 21.1

31.1

40

50 data book

64 86

66 88

1 5/8 3/4 1 1/8 450 ~ 1170 64 £20,619.00

Price List 2015

61

VRV

Outdoor Units


REYQ-T (38 to 42 HP)

VRV IV Condensing Units – Heat Recovery Outdoor Units Capacity

VRV

Dimensions

Weight Fan Electrical Details

Refrigerant Circuit

38 HP Multi Nominal Cooling Nominal Heating Height x Width x Depth

Air Flow Rate Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge

kW kW mm

kg m3/sec Phase amps amps amps

REYQ12T

1685 x 930 x 765

106.40 106.40 1685 x 930 x 765

210 2.70

218 3.08

1685 x 1240 x 765 337 4.18

8.9

15.3

24.6

20

25

40

Capacity Index Limit Maximum Number of Connected Indoor Units

data book data book 61 81 1000 165 1 5/8 3/4 1 3/8 475 ~ 1235 64

Trade Condensing Unit Price

£22,147.00

Sound Pressure Sound Power Piping Limits Piping Connections Systems

Maximum Total Length Maximum Actual Length Liquid Gas Discharge

kg kg dBA dBA m m inches inches inches

40 HP Multi

REYQ8T

58 78

REYQ18T

65 86

REYQ10T

REYQ12T

1685 x 930 x 765

111.50 111.50 1685 x 930 x 765

42 HP Multi REYQ18T

1685 x 1240 x 765 205 205 329 2.92 3.08 4.18 3ph / 50 Hz / 380~415V 11.8 15.3 24.6 4 25 25 40 R410A data book data book 58 61 65 79 81 86 1000 165 1 5/8 3/4 1 3/8 500 ~ 1300 64

REYQ10T

REYQ16T

REYQ16T

205 2.92

118.00 118.00 1685 x 1240 x 765 319 4.33

1685 x 1240 x 765 319 4.33

11.8

21.1

21.1

25

40

40

1685 x 930 x 765

58 79

£22,368.00

data book data book 64 86 1000 165 1 5/8 3/4 1 3/8 525 ~ 1365 64

64 86

£23,923.00

REYQ-T (44 to 48 HP)

VRV IV Condensing Units – Heat Recovery Outdoor Units

44 HP Multi REYQ12T

Capacity Dimensions

Weight Fan Electrical Details

Refrigerant Circuit

Nominal Cooling Nominal Heating Height x Width x Depth

Air Flow Rate Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge

kW kW mm

kg m3/sec Phase amps amps amps

205 3.08

1685 x 1240 x 765 319 4.33

15.3

21.1

21.1

25

40

40

1685 x 930 x 765

Capacity Index Limit Maximum Number of Connected Indoor Units Trade Condensing Unit Price

£25,087.00

Piping Connections Systems

62

Maximum Total Length Maximum Actual Length Liquid Gas Discharge

Residential, Commercial and Industrial

46 HP Multi REYQ16T

123.50 123.50 1685 x 1240 x 765 319 4.33

data book data book 64 86 1000 165 1 5/8 3/4 1 3/8 550 ~ 1430 64

Sound Pressure Sound Power Piping Limits

kg kg dBA dBA m m inches inches inches

REYQ16T

61 81

64 86

REYQ14T

REYQ16T

48 HP Multi REYQ16T

130.00 130.00 1685 x 1685 x 1685 x 1240 x 1240 x 1240 x 765 765 765 319 319 319 3.72 4.33 4.33 3ph / 50 Hz / 380~415V 17.4 21.1 21.1 4 32 40 40 R410A data book data book 61 64 64 81 86 86 1000 165 1 5/8 3/4 1 3/8 575 ~ 1495 64 £26,275.00

REYQ16T

REYQ16T

REYQ16T

1685 x 1240 x 765 319 4.33

135.00 135.00 1685 x 1240 x 765 319 4.33

1685 x 1240 x 765 319 4.33

21.1 40

64 86

40 data book data book 64 86 1000 165 1 5/8 3/4 1 3/8 600 ~ 1560 64 £27,672.00

40

64 86


REYQ-T (50 to 54 HP)

VRV IV Condensing Units – Heat Recovery Capacity Dimensions

Weight Fan Electrical Details

Refrigerant Circuit

50 HP Multi Nominal Cooling Nominal Heating Height x Width x Depth

Air Flow Rate Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge

kW kW mm

kg m3/sec Phase amps amps amps

REYQ16T

1685 x 1240 x 765 319 4.33

140.00 140.00 1685 x 1240 x 765 319 4.33

1685 x 1240 x 765 329 4.18

21.1

21.1

24.6

40

40

40

Capacity Index Limit Maximum Number of Connected Indoor Units

data book data book 64 86 1000 165 1 5/8 3/4 1 3/8 625 ~ 1625 64

Trade Condensing Unit Price

£28,907.00

Sound Pressure Sound Power Piping Limits Piping Connections Systems

Maximum Total Length Maximum Actual Length Liquid Gas Discharge

kg kg dBA dBA m m inches inches inches

52 HP Multi

REYQ16T

64 86

REYQ18T

65 86

REYQ16T

REYQ18T

54 HP Multi REYQ18T

145.00 145.00 1685 x 1685 x 1685 x 1240 x 1240 x 1240 x 765 765 765 319 329 329 4.33 4.18 4.18 3ph / 50 Hz / 380~415V 21.1 24.6 24.6 4 40 40 40 R410A data book data book 64 65 65 86 86 86 1000 165 1 5/8 3/4 1 3/8 650 ~ 1690 64 £29,732.00

REYQ18T

REYQ18T

REYQ18T

1685 x 1240 x 765 329 4.18

150.00 150.00 1685 x 1240 x 765 329 4.18

1685 x 1240 x 765 329 4.18

VRV

Outdoor Units

24.6 40

65 86

40 data book data book 65 86 1000 165 1 5/8 3/4 1 3/8 675 ~ 1755 64

40

65 86

£30,762.00

Price List 2015

63


RYYQ-T Replaces RXYQ-P9 / RXYHQ-P9 / RXYRQ-P9 / RXHQ-P

Heat Pump VRV IV

VRV

3 revolutionary features: Variable refrigerant temperature Customise your VRV for best Seasonal Efficiency and comfort: > R evolutionary variable refrigerant temperature control automatically adapts the system to individual building and climate requirements for greater efficiency and comfort > C ontinuously adjusts refrigerant temperature to the actual temperature and capacity required > D efault mode optimised by Daikin for UK conditions with maximum efficiency and comfort > Delivers annual cost savings of up to 28%

VRV configurator

Continuous heating during defrost

Advanced software for simplified commissioning, servicing, configuration and customisation:

The new standard in heating comfort:

> Simplified commissioning: graphical interface to configure, commission and upload system settings

> U nique continuous heating technology makes VRV IV Heat Pump the best alternative to traditional heating systems > Delivers uninterrupted heat, even during the defrost cycle

> Simplified servicing: additional 7-segment indicator for easy and quick access to basic functions and error read out

> Maintains comfortable indoor climate at all times

> Manage systems over multiple sites

RYYQ-T (up to 20 HP)

VRV IV Heat Pump with Continuous Heating Outdoor Units Capacity EER ESEER COP Dimensions Weight Air Flow Rate External Static Pressure Electrical Details

Refrigerant Circuit

Sound Pressure Sound Power Piping Limits Piping Connections

Nominal Cooling Nominal Heating

kW kW

Height x Width x Depth

mm

High Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge

Maximum Length Maximum Vertical Rise Liquid Gas

kg m3/sec Pa Phase /Hz / V amps amps amps kg kg dBA dBA m m inches inches

Capacity Index Limit Maximum Number of Connected Indoor Units Trade Condensing Unit Price

RYYQ8T

RYYQ10T

RYYQ12T

22.40 25.00 4.30 7.53* 4.55 1685 x 930 x 765 261 2.70 78

28.00 31.50 3.84 7.2* 4.27 1685 x 930 x 765 268 2.92 78

33.50 37.50 3.73 6.96* 4.12 1685 x 930 x 765 268 3.08 78

7.2

11.3

20

25

5.9

6.0

58 78 165

58 79 165

3/8 3/4 100~260 64

3/8 7/8 125~325 64

£4,542.00

£4,963.00

RYYQ14T

RYYQ16T

40.00 45.00 45.00 50.00 3.64 3.46 6.83* 6.5* 4.02 3.91 1685 x 1240 1685 x 1240 x 765 x 765 364 364 3.72 4.33 78 78 3ph / 50 Hz / 380~415V 12.7 15.4 18.0 databook 32 32 40 R410a 6.3 10.3 10.4 data book 61 61 64 81 81 86 165 165 165 data book 1/2 1/2 1/2 1 1/8 1 1/8 1 1/8 150~390 175~455 200~520 64 64 64

£6,077.00

£7,090.00

£8,183.00

RYYQ18T

RYYQ20T

50.00 56.00 3.40 6.38* 3.89 1685 x 1240 x 765 398 4.18 78

56.00 63.00 3.03 5.67* 3.71 1685 x 1240 x 765 398 4.35 78

20.8

26.9

40

50

11.7

11.8

65 86 165

66 88 165

5/8 1 1/8 225~585 64

5/8 1 1/8 250~650 64

£9,116.00

£10,028.00

* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).

64

Residential, Commercial and Industrial


RYYQ-T (22 to 24 HP)

VRV IV Heat Pump with Continuous Heating RYYQ22T

RYYQ24T

RYMQ10T Capacity EER ESEER COP Dimensions Weight Air Flow Rate External Static Pressure Electrical Details

Refrigerant Circuit

Sound Pressure Sound Power Piping Limits Piping Connections

Nominal Cooling Nominal Heating

kW kW

Height x Width x Depth

mm kg m3/sec Pa Phase /Hz / V amps amps amps

High Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge

Maximum Length Maximum Vertical Rise Liquid Gas

RYMQ12T

RYMQ8T

RYMQ16T

61.50 69.00 3.77 7.07* 4.18

67.40 75.00 3.70 6.81* 4.10

1685 x 930 x 765 195 2.92 78

1685 x 930 x 765 1685 x 930 x 765 195 188 3.08 2.70 78 78 3ph / 50 Hz / 380~415V 12.7 7.2 databook 32 20 R410a 6.3 5.9 databook 61 58 81 78

10.2 25

kg kg dBA dBA m m inches inches

6.0 58 79

1685 x 1240 x 765 309 4.33 78

VRV

Outdoor Units

18.0 40 10.4 64 86

165

165 databook

Capacity Index Limit Maximum Number of Connected Indoor Units Trade Condensing Unit Price

5/8 1 1/8 275~715 64

5/8 1 3/8 300~780 64

£11,040.00

£12,725.00

* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).

RYYQ-T (26 to 34 HP)

VRV IV Heat Pump with Continuous Heating Outdoor Units

RYYQ26T

RYYQ28T

RYYQ30T

RYYQ32T

RYYQ34T

RYMQ12T RYMQ14T RYMQ12T RYMQ16T RYMQ12T RYMQ18T RYMQ16T RYMQ16T RYMQ16T RYMQ18T Capacity EER ESEER COP Dimensions

Weight Air Flow Rate External Static Pressure Electrical Details

Refrigerant Circuit

Sound Pressure Sound Power Piping Limits Piping Connections

Nominal Cooling Nominal Heating

kW kW

Height Width Depth

mm mm mm kg m3/sec Pa Phase /Hz / V amps amps amps

High Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge

Maximum Length Maximum Vertical Rise Liquid Gas

Capacity Index Limit Maximum Number of Connected Indoor Units Trade Condensing Unit Price

kg kg dBA dBA m m inches inches

73.50 82.50 3.68 6.89* 4.06

78.50 87.50 3.57 6.69* 4.00

83.50 93.50 3.52 6.6* 3.98

1685 930 765 195 3.08 78

1685 1240 765 309 3.72 78

1685 930 765 195 3.08 78

1685 1240 765 309 4.33 78

3/4 1 3/8 325~845 64

3/4 1 3/8 350~910 64

1685 1685 930 1240 765 765 195 319 3.08 4.18 78 78 3ph / 50 Hz / 380~415V 12.7 20.8 databook 32 40 R410a 6.3 11.7 data book 61 65 81 86 165 data book 3/4 1 3/8 375~975 64

12.7

15.4

12.7

18.0

32

32

32

40

6.3

10.3

6.3

10.4

61 81

61 81

61 81

64 86

£13,167.00

£14,260.00

£15,193.00

90.00 100.00 3.46 6.5* 3.91

95.00 106.00 3.43 6.44* 3.90

1685 1240 765 309 4.33 78

1685 1240 765 309 4.33 78

1685 1240 765 309 4.33 78

1685 1240 765 319 4.18 78

18.0

18.0

18.0

20.8

40

40

40

40

10.4

10.4

10.4

11.7

64 86

64 86

64 86

65 86

3/4 1 3/8 400~1040 64

3/4 1 3/8 425~1105 64

£16,366.00

£17,299.00

* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).

Price List 2015

65


RYYQ-T (36 to 42 HP)

VRV IV Heat Pump with Continuous Heating Outdoor Units

RYYQ36T

RYYQ38T

RYYQ40T

RYYQ42T

RYMQ16T RYMQ20T RYMQ8T RYMQ10T RYMQ20T RYMQ10T RYMQ12T RYMQ18T RYMQ10T RYMQ16T RYMQ16T

VRV

Capacity EER ESEER COP Dimensions

Weight Air Flow Rate External Static Pressure Electrical Details

Refrigerant Circuit

Sound Pressure Sound Power Piping Limits Piping Connections

Nominal Cooling Nominal Heating

kW kW

Height Width Depth

mm mm mm kg m3/sec Pa Phase /Hz / V amps amps amps

High Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge

Maximum Length Maximum Vertical Rise Liquid Gas

kg kg dBA dBA m m inches inches

Capacity Index Limit Maximum Number of Connected Indoor Units Trade Condensing Unit Price

101.00 113.00 3.21 6.02* 3.79 1685 1685 1240 1240 765 765 309 319 4.33 4.35 78 78

106.00 120.00 3.42 6.36* 4.01 1685 930 765 195 2.92 78

1685 930 765 188 2.70 78

18.0 26.9 databook 40 50

7.2 20

10.2 databook 25

10.4

11.8

5.9

6.0

64 86

66 88

58 78

58 79

3/4 1 5/8 450~1170 64

3/4 1 5/8 475~1235 64

£18,211.00

£19,533.00

112.00 125.00 3.61 6.74* 4.05 1685 1685 1685 1240 930 930 765 765 765 319 195 195 4.35 2.92 3.08 78 78 78 3ph / 50 Hz / 380~415V 26.9 10.2 12.7 databook 50 25 32 R410a 11.8 6.0 6.3 data book 66 58 61 88 79 81 165 data book 3/4 1 5/8 500~1300 64

1685 1240 765 319 4.18 78

1685 930 765 195 2.92 78

20.8

10.2

40

118.00 132.00 3.54 6.65* 4.00 1685 1240 765 309 4.33 78

1685 1240 765 309 4.33 78 18.0

25

18.0 databook 40

11.7

6.0

10.4

10.4

65 86

58 79

64 86

64 86

40

3/4 1 5/8 525~1365 64

£20,156.00

£21,329.00

* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).

RYYQ-T (44 to 48 HP)

VRV IV Heat Pump with Continuous Heating Outdoor Units Capacity EER ESEER COP Dimensions

Weight Air Flow Rate External Static Pressure Electrical Details

Refrigerant Circuit

Sound Pressure Sound Power Piping Limits Piping Connections

RYYQ44T Nominal Cooling Nominal Heating

kW kW

Height Width Depth

mm mm mm kg m3/sec Pa Phase /Hz / V amps amps amps

High Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge

Maximum Length Maximum Vertical Rise Liquid Gas

kg kg dBA dBA m m inches inches

Capacity Index Limit Maximum Number of Connected Indoor Units Trade Condensing Unit Price

RYMQ12T

RYMQ16T

1685 930 765 195 3.08 78

124.00 138.00 3.54 6.62* 3.98 1685 1240 765 309 4.33 78

12.7

RYYQ46T RYMQ16T

RYMQ14T

RYMQ16T

RYYQ48T RYMQ16T

3/4 1 5/8 550~1430 64

130.00 145.00 3.51 6.6* 3.94 1685 1685 1685 1240 1240 1240 765 765 765 309 309 309 3.72 4.33 4.33 78 78 78 3ph / 50 Hz / 380~415V 15.4 18.0 18.0 databook 32 40 40 R410a 10.3 10.4 10.4 data book 61 64 64 81 86 86 165 data book 3/4 1 5/8 575~1495 64

£22,443.00

£23,456.00

1685 1240 765 309 4.33 78 18.0

32

18.0 databook 40

6.3

10.4

10.4

61 81

64 86

64 86

40

RYMQ16T

RYMQ16T

RYMQ16T

1685 1240 765 309 4.33 78

135.00 150.00 3.46 6.5* 3.91 1685 1240 765 309 4.33 78

1685 1240 765 309 4.33 78

18.0

18.0

40

18.0 databook 40

10.4

10.4

10.4

64 86

64 86

64 86

40

3/4 1 5/8 600~1560 64 £24,549.00

* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).

66

Residential, Commercial and Industrial


RYYQ-T (50 to 54 HP)

VRV IV Heat Pump with Continuous Heating Capacity EER ESEER COP Dimensions

Weight Air Flow Rate External Static Pressure Electrical Details

Refrigerant Circuit

Sound Pressure Sound Power Piping Limits Piping Connections

RYYQ50T RYMQ16T

RYMQ16T 140.00 156.00 3.44 6.46* 3.90 1685 1240 765 309 4.33 78

Nominal Cooling Nominal Heating

kW kW

Height Width Depth

mm mm mm kg m3/sec Pa Phase amps amps amps

1685 1240 765 309 4.33 78

kg kg dBA dBA m m inches inches

High Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge

Maximum Length Maximum Vertical Rise Liquid Gas

Capacity Index Limit Maximum Number of Connected Indoor Units Trade Condensing Unit Price

18.0

RYYQ52T RYMQ18T

RYMQ16T

RYMQ18T

RYYQ54T RYMQ18T

3/4 1 5/8 625~1625 64

145.00 162.00 3.42 6.42* 3.89 1685 1685 1685 1240 1240 1240 765 765 765 309 319 319 4.33 4.18 4.18 78 78 78 3ph / 50 Hz / 380~415V 18.0 20.8 20.8 databook 40 40 40 R410a 10.4 11.7 11.7 data book 64 65 65 86 86 86 165 data book 3/4 1 5/8 650~1690 64

£25,482.00

£26,415.00

1685 1240 765 319 4.18 78 20.8

40

18.0 databook 40

10.4

10.4

11.7

64 86

64 86

65 86

40

RYMQ18T

RYMQ18T

RYMQ18T

1685 1240 765 319 4.18 78

150.00 168.00 3.40 6.38* 3.89 1685 1240 765 319 4.18 78

1685 1240 765 319 4.18 78

20.8

20.8

40

20.8 databook 40

11.7

11.7

11.7

65 86

65 86

65 86

VRV

Outdoor Units

40

3/4 1 5/8 675~1755 64 £27,348.00

* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).

Price List 2015

67


VRV

Unseen in all the best places

Keep a low profile We’re keeping a low profile with our new VRV IV S-series. Standing less than 1m from the ground including feet, our new compact VRV IV S-series is the lowest profile VRV unit in the market today. So it’s perfect for all kinds of tight spots and urban spaces. Available in 4 & 5 HP single phase, this lightweight single-fan unit joins our newly extended range of double-fan VRV IV S-series available in either single or 3-phase. All have front-blow, so can be located on a balcony or enclosed area. Plus every unit in the range now features VRV IV technology with variable refrigerant temperature control. So now you can get all the power of a VRV, in the smallest of spaces.

Find out more at www.daikin.co.uk

1 Residential, Commercial and Industrial 68 Daikin_miniVRV_ad_UK_260x180_UKversion.indd

16/02/2015 14:28:22


AVAILABLE MID 2015

RXYSCQ

Low Height Mini VRV

Outdoor Units Capacity Dimensions Weight Refrigerant Circuit Sound Pressure Sound Power Piping Limits Piping Connections

Nominal Cooling Nominal Heating Height x Width x Depth Refrigerant Type (Cooling) (Cooling) Maximum Length Maximum Vertical Rise Liquid Gas

kW kW mm kg

RXYSCQ4

RXYSCQ5

12.1 12.1 823 x 940 x 460 88

14 14 823 x 940 x 460 88 R410a

dBA dBA m m inches inches

51 68 70 30 3/8 5/8 50~130

3/8 5/8 62.5~162.5

£2,462.00

£2,767.00

Capacity Index Limit Trade Condensing Unit Price

52 69

VRV

NEW

823mm high

Less than 1m

> New low height Mini VRV, making complying with planning restrictions in towns and cities easier > Compact – Only 823mm high > Lightweight – for simple installation > Variable Refrigerant temperature – Enhanced efficiency > In addition to VRV fan coils, low height Mini VRV is connectable to: Stylish indoor units – Emura and Nexura Air Handling Units Biddle Air Curtains > Single phase

Parapet wall

Features:

Roof

823mm

1345mm

Planning issues for small commercial or residential projects in towns and cities can now be easy to overcome with a Low height version of the mini VRV range, available in 4 & 5HP with Variable Refrigerant Temperature and connection to products such as Air Curtains, Air handling units and the Emura and Nexura fan coils, the Low height Mini VRV range brings a whole new level of versatility to the VRV range.

Price List 2015

69


RXYSQ

VRV III Condensing Units – Heat Pump Inverter Mini Updated VRV IV version including Variable Refrigerant Temperature control available during autumn 2015. Outdoor Units

VRV

Capacity Dimensions Weight Air Flow Rate Electrical Details

Refrigerant Circuit

Sound Pressure Sound Power Piping Limits Piping Connections

Nominal Cooling Nominal Heating Height x Width x Depth

Power Supply

Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge

Maximum Length Maximum Vertical Rise Liquid Gas

kW kW mm kg m3/sec Phase Hz V amps amps amps kg kg dBA dBA m m inches inches

Capacity Index Limit Maximum Number of Connected Indoor Units Trade Condensing Unit Price

RXYSQ4P8V1

RXYSQ5P8V1

RXYSQ6P8V1

RXYSQ4P8Y1

RXYSQ5P8Y1

RXYSQ6P8Y1

12.60 14.20 1345 x 900 x 320 120 1.77

14.00 16.00 1345 x 900 x 320 120 1.77 1ph 50 230 20.2 4 32

15.50 18.00 1345 x 900 x 320 120 1.77

12.60 14.20 1345 x 900 x 320 120 1.77

15.50 18.00 1345 x 900 x 320 120 1.77

22.2 4 32

5.3 4 16

14.00 16.00 1345 x 900 x 320 120 1.77 3ph 50 400 6.8 4 16

50 66

51 67

53 69

15.9 4 32

7.8 4 16

R410a 4.0 data book 50 66

51 67

53 69 300 data book

3/8 5/8 50~130 8

3/8 5/8 62.5~162.5 10

3/8 3/4 70~182 12

3/8 5/8 50~130 8

3/8 5/8 62.5~162.5 10

3/8 3/4 70~182 12

£2,735.00

£3,074.00

£3,431.00

£2,788.00

£3,160.00

£3,510.00

Notes: The VRV III-S is highly space saving, featuring a slimmer and more compact outdoor unit compared to conventional models. Supplied in three sizes of 4 HP (11.2 kW), 5HP (14 kW) and 6HP (15.5 kW) with a single or three phase power supply. Compatible with the full range of existing VRV fan coil units providing a choice of 12 types and 72 models. Installation is improved by the completely new casing design of the outdoor unit with a footprint of just 320mm deep by 900mm wide, which reduces installation space requirements by over 40% (14.0kW model) and enables it to fit easily onto balconies and narrow ledges. Maximum piping length is 150m, total piping length is 300m and maximum vertical differential between outdoor and indoor units is 50m (40m when outdoor is below indoor units). The Daikin ‘Super Wiring’ system allows shared use of the wiring between indoor and outdoor units and the centralised remote control, the non polarity of the system obviating incorrect connection and reducing installation time.

Advanced technologies

1 2 3

3

2

Super aero grille The spiral shaped ribs are aligned with the direction of discharge flow in order to minimise turbulence and reduce noise.

Smooth air inlet bell mouth and aero spiral fan

1

These features assist in significantly reducing noise. Guides are added to the bell mouth intake to reduce turbulence in the air flow generated by fan suction. The aero spiral fan features fan blades with bent blade edges, further reducing turbulence.

e-Bridge circuit Prevents accumulation of liquid refrigerant in the condenser. This results in more efficient use of the condenser surface under all conditions and leads in turn to better energy efficiency. Increased evaporative capacity stems from the newly developed refrigeration circuit, the SCe-bridge circuit, which adds super cooling prior to the expansion cycle. By adopting this circuit, the COPs in both cooling and heating have been drastically improved.

Aero spiral fan blade tips

Conventional

New

Escaping edges are sucked in by the bent blade edges, reducing overall turbulence.

70

Residential, Commercial and Industrial


RWEYQ-T8

Water cooled VRV

VRV

Water cooled VRV uses water as it’s source of heat. This enables not just heat recovery on each system, but also heat recovery between different systems, maximising efficiency. Additionally there is no defrost required on these units meaning heating comfort is maintained even during cold spells.

Ideal for large buildings VRV-W systems are capable of coping with water pressures of 2MPa and provide pipework lengths of up to 120m length from condenser to fan coils. The new VRV IV features are already available on water cooled VRV systems including:

> T he standard model is now capable of accepting geothermal water temperatures (Down to -10 Deg C with glycol)

> V ariable Refrigerant Temperature – delivering far higher efficiency than any other comparable system and ensuring comfort by raising off coil temperatures, Variable Refrigerant Temperature control delivers a leap forwards in VRV technology.

> Inverter water pump controller (available on request)

> C onfigurator – Simplified commissioning: graphical interface to configure, commission and upload system settings. Manage systems over multiple sites, saves time and reduces errors during set-up and commissioning.

> C onnect to AHU applications and Heat Reclaim Ventilation devices > Now it’s even possible to connect VRV IV BS boxes, including the small, light Multi BS boxes designed to offer the largest & most flexible range of design & installation options available.* * VRV IV single and multi BS Box connectivity coming spring 2015, please speak to your local Daikin representative to ensure your system design is available for delivery when your project starts

Price List 2015

71


Heat Pump and Heat Recovery RWEYQ-T8 (up to 24 HP)

VRV IV Water Cooled Condensing Units Outdoor Units

RWEYQ8T8 RWEYQ10T8

RWEYQ16T8

RWEYQ18T8

RWEYQ20T8

RWEYQ24T8

RWEYQ8T8 RWEYQ8T8 RWEYQ8T8 RWEYQ10T8 RWEYQ10T8 RWEYQ10T8 RWEYQ8T8 RWEYQ8T8 RWEYQ8T8 Capacity

VRV

EER COP Dimensions

Weight Electrical Details

Refrigerant Circuit

Nominal Cooling Nominal Heating

kW kW

Height Width Depth

mm mm mm kg Phase /Hz/v amps amps amps

Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge

Sound Pressure Piping Limits

Maximum Length Maximum Vertical Rise Piping Connections Liquid Gas Discharge pipe size - Heat Recovery Only Capacity Index Limit Maximum Number of Connected Indoor Units

kg kg dBA m m inches inches inches

Trade Condensing Unit Price

22.40 25.00 5.07 5.94 1000 780 550 137

28.00 31.50 4.56 5.25 1000 780 550 137

7.2 4 20

9.5 4 20

44.80 50.00 5.07 5.94 1000 780 550 137

50.40 56.50 4.77 5.53 1000 780 550 137

1000 780 550 137

1000 780 550 137 3ph / 50 / 400 16.7 4 32 R410a 3.5 4.2 data book 54 120 50 5/8 1 1/8 225~585 36

14.4 4 32

3.5 4.2 data book data book 50 51 120 120 50 50 3/8 3/8 3/4 7/8 100~260 125~325 36 36

3.5 3.5 data book 53 120 50 1/2 1 1/8 200~520 36

£5,524.00 £6,807.00

£11,048.00

£12,331.00

56.00 63.00 4.56 5.25 1000 780 550 137

1000 780 550 137

67.20 75.00 5.07 5.94 1000 780 550 137

1000 780 550 137

19.0 4 32

1000 780 550 137

21.6 4 50

4.2 4.2 data book 54 120 50 5/8 1 1/8 250~650 36

3.5

£13,614.00

3.5 data book 55 120 50 3/4 1 3/8 300~780 36

3.5

£16,572.00

Notes: Daikin have introduced the new VRV IV Water Cooled condensing unit to compliment the rest of the VRV range. The water cooled system has a number of advantages over an air cooled system: • suitable for tall multi-storied buildings due to no limitations of water piping length • wide operation range with inlet water temperatures of -10 - 45°C • suitable for use with open and closed loop ground source systems on request • the system offers greater efficiency in heating mode as there is no defrost cycle required for the water loop • greater efficiencies than air cooled systems

Heat Pump and Heat Recovery RWEYQ-T8 (26 to 30 HP)

VRV IV Water Cooled Condensing Units Outdoor Units

RWEYQ26T8 RWEYQ8T8

Capacity EER COP Dimensions

Weight Electrical Details

Refrigerant Circuit

Nominal Cooling Nominal Heating

kW kW

Height Width Depth

mm mm mm kg Phase amps amps amps

1000 780 550 137

kg kg dBA m m inches inches inches

4

Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge

Sound Pressure Piping Limits

Maximum Length Maximum Vertical Rise Piping Connections Liquid Gas Discharge pipe size - Heat Recovery Only Capacity Index Limit Maximum Number of Connected Indoor Units Trade Condensing Unit Price

RWEYQ28T8

RWEYQ30T8

RWEYQ8T8 RWEYQ10T8 RWEYQ8T8 RWEYQ10T8 RWEYQ10T8 RWEYQ10T8 RWEYQ10T8 RWEYQ10T8 72.80 81.50 4.86 5.65 1000 780 550 137

55 120 50 3/4 1 3/8 325~845 36

78.40 88.00 4.69 5.43 1000 780 550 137 3ph / 50 / 400 26.2 4.0 50 R410a 4 data book 55 120 50 3/4 1 3/8 350~910 36

£17,855.00

£19,138.00

1000 780 550 137

1000 780 550 137

23.9 4.0 50 4

4

4

1000 780 550 137

1000 780 550 137

84.00 94.50 4.56 5.25 1000 780 550 137 28.5 4.0 50

4

4

4 56 120 50 3/4 1 3/8 375~975 36 £20,421.00

Notes: The VRV IV Water Cooled system is supplied as a common unit and can be used in either heat pump and heat recovery modes, from size 10 to size 30 all using a three phase power supply. The 30 hp system can connect to up to 36 indoor units. The system is fully compatible with the full range of existing VRV fan coils and controls packages. The condensing unit is small with a foot print of 780 x 550 mm and a height of 1000 mm. Running quality with a sound pressure level of 51dB(A), it should be installed in a plant room.

72

Residential, Commercial and Industrial

1000 780 550 137

4


RXYQQ-T / RQEQ-P3

Replacement VRV-Q Optimise your business Due to faster installation. VRV-Q is more profitable than replacing the full system with new piping.

Lower installation costs: Offer customers the most cost-effective solution and improve your competitive edge.

Easy as one-two-three:

New VRV

Tackle more projects in less time:

Now it's possible to connect VRV IV BS boxes, including the small, light Multi BS boxes designed to offer the largest & most flexible range of design & installation options available.* * VRV IV single and multi BS Box connectivity coming spring 2015, please speak to your local Daikin representative to ensure your system design is available for delivery when your project starts.

A simple solution: Daikin VRV-Q enables you to handle more projects for more customers in less time and offer them the best price! Everybody wins.

Compare installation steps Conventional solution 1 Recover refrigerant 2 Remove units 3 Remove refrigerant pipes

VRV-Q 1 Recover refrigerant 2 Remove units Re-use existing piping and wiring

5 Install new units

3 Install new units

6 Leak test

4 Leak test

7 Vacuum drying

5 Vacuum drying

9 Collect contamination 10 Test operation

4

6 Automatic refrigerant charging, cleaning and testing

Reuse drain pipes

Durable PVC pipes can be easily reused. Only flow tests are required.

4

4 Install new piping/wiring

8 Refrigerant charging

The Daikin low-cost upgrade solution Reuse refrigerant pipes

Pipes used for R-22 will also work with VRV-Q, thanks to lower operating pressures of the system.

4

Reuse refrigerant branch pipes

There are no restrictions when upgrading from a Daikin VRV system. Other VRF systems require branch pipes to withstand pressure up to 3.3 MPa.

!

Replace indoor units and BS boxes

Contact your local dealer to check compatibility in case you need to keep the indoor units.

4

Reuse remote control wiring

Reuse wiring when upgrading from a Daikin VRV system. In other cases, this will depend on the cable type.

Up to 45% shorter installation time

Customer benefits

4

Reuse indoor-outdoor wiring

Restrictions: see remote control wiring.

!

Replace outdoor units

Always operational Avoid loss of business Replacing now prevents unplanned, lengthy disruption of air conditioning systems. It also avoids loss of business for shops, complaints from guests in hotels, lower working efficiency and loss of tenants in offices.

Reduced energy consumption

Quick and easy installation No interruption of daily business while replacing the system thanks to phased-in, fast installation. Comparison of 10HP systems:

Lower long-term costs EU Directives prohibit system repairs with R-22 after 31 December 2014. Replacement day has arrived. Installing a technically advanced system lowers energy consumption and maintenance costs from day one.

Cooling mode Heating mode R-22 (RSXY-KA7)

R-407C (RSXYP-L7) R-410A (RXYQQ-T)

Price List 2015

73


RXYQQ-T (up to 20 HP)

VRV IV-Q Condensing Unit – Heat Pump Outdoor Units Capacity

VRV

EER ESEER COP Dimensions

Weight Air Flow Rate External Static Pressure Electrical Details

Refrigerant Circuit

Sound Pressure Sound Power Piping Limits Piping Connections

Nominal Cooling Nominal Heating

kW kW

Height Width Depth

mm mm mm kg m3/sec Pa Phase /Hz / V amps amps amps

High Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge

Maximum Length Maximum Vertical Rise Liquid Gas

kg kg dBA dBA m m inches inches

Capacity Index Limit Maximum Number of Connected Indoor Units Trade Condensing Unit Price

RXYQQ8T

RXYQQ10T

RXYQQ12T

RXYQQ14T

RXYQQ16T

RXYQQ18T

RXYQQ20T

22.40 25.00 4.30 7.53* 4.54 1685 930 765 187 2.10 78

28.00 31.50 3.84 7.2* 4.27 1685 930 765 194 2.92 78

33.50 37.50 3.73 6.96* 4.12 1685 930 765 194 3.08 78

45.00 50.00 3.46 6.5* 3.91 1685 1240 765 305 3.88 78

50.00 56.00 3.40 6.38* 3.89 1685 1240 765 314 4.18 78

56.00 63.00 3.03 5.67* 3.71 1685 1240 765 314 4.35 78

7.2

10.2

12.7

18.0

20.8

26.9

20

25

32

40

40

50

5.2

6.0

6.3

10.4

11.7

11.8

58 78 120

58 79 120

61 81 120

64 86 120

65 86 120

66 88 120

3/8 3/4 100~260 64

3/8 7/8 125~325 64

1/2 1 1/8 150~390 64

40.00 45.00 3.64 6.83* 4.02 1685 1240 765 306 3.72 78 3ph / 50 / 400 15.4 4 32 R410a 10.3 data book 61 81 120 50 1/2 1 1/8 175~455 64

1/2 1 1/8 200~520 64

5/8 1 1/8 225~585 64

5/8 1 1/8 250~650 64

£5,077.00

£5,548.00

£6,435.00

£7,508.00

£8,665.00

£10,165.00

£11,161.00

*The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrifgerant temperature control operation).

Please contact your local sales office regarding VRV IV-Q warranty and installation.

RXYQQ-T (22 to 28 HP)

VRV IV-Q Condensing Unit – Heat Pump Outdoor Units

RXYQQ22T RXYQQ10T

Capacity EER ESEER COP Dimensions

Weight Air Flow Rate External Static Pressure Electrical Details

Refrigerant Circuit

Sound Pressure Sound Power Piping Limits Piping Connections

Nominal Cooling Nominal Heating

kW kW

Height Width Depth

mm mm mm kg m3/sec Pa Phase /Hz / V amps amps amps

High Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge

Maximum Length Maximum Vertical Rise Liquid Gas

RXYQQ24T

RXYQQ12T

RXYQQ8T

61.50 69.00 3.77 7.07* 4.18 1685 930 765 194 2.92

RXYQQ26T

RXYQQ16T

RXYQQ12T

67.40 75.00 3.70 6.81* 4.10 1685 930 765 194 3.08

1685 930 765 187 2.10

78

RXYQQ28T

RXYQQ14T

RXYQQ12T

73.50 82.50 3.68 6.89* 4.06 1685 1240 765 305 3.88

1685 930 765 194 3.08

78

RXYQQ16T

78.50 87.50 3.57 6.69* 4.00 1685 1240 765 306 3.72

1685 930 765 194 3.08

1685 1240 765 305 3.88

78

78

28.1

30.7

3ph / 50 / 400 22.9

25.2 88

25

32

20

40

32

32

32

40

6.3

10.3

6.3

10.4

61 81

61 81

61 81

64 86

R410a kg kg dBA dBA m m inches inches

Capacity Index Limit Maximum Number of Connected Indoor Units Trade Condensing Unit Price

6.0

6.3

5.2

10.4 data book

58 79

61 81

58 78

64 86 120 50

5/8 1 1/8 275~715 64

5/8 1 3/8 300~780 64

3/4 1 3/8 325~845 64

3/4 1 3/8 350~910 64

£11,983.00

£13,742.00

£13,943.00

£15,100.00

*The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrifgerant temperature control operation).

Please contact your local sales office regarding VRV IV-Q warranty and installation. 74

Residential, Commercial and Industrial


RXYQQ-T (30 to 36 HP)

VRV IV-Q Condensing Unit – Heat Pump RXYQQ30T RXYQQ12T Capacity EER ESEER COP Dimensions

Weight Air Flow Rate External Static Pressure Electrical Details

Refrigerant Circuit

Sound Pressure Sound Power Piping Limits Piping Connections

Nominal Cooling Nominal Heating

kW kW

Height Width Depth

mm mm mm kg m3/sec Pa Phase /Hz / V amps amps amps

High Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge

Maximum Length Maximum Vertical Rise Liquid Gas

RXYQQ32T

RXYQQ18T

RXYQQ16T

83.50 93.50 3.52 6.6* 3.98

RXYQQ34T

RXYQQ16T

RXYQQ16T

90.00 100.00 3.46 6.5* 3.91

1685 930 765 194 3.08

1685 1240 765 314 4.18

1685 1240 765 305 3.88

78

RXYQQ36T

RXYQQ18T

RXYQQ16T

95.00 106.00 3.43 6.44* 3.90 1685 1240 765 305 3.88

1685 1240 765 305 3.88

78

RXYQQ20T

101.00 113.00 3.21 6.02* 3.79 1685 1240 765 314 4.18

1685 1240 765 305 3.88

1685 1240 765 314 4.35

78

78

38.8

44.9

VRV

Outdoor Units

3ph / 50 / 400 33.5

36.0 108

32

40

40

40

40

40

40

50

10.4

11.7

10.4

11.8

64 86

65 86

64 86

66 88

R410a kg kg dBA dBA m m inches inches

6.3

11.7

10.4

10.4 data book

61 81

65 86

64 86

64 86 120 50

Capacity Index Limit Maximum Number of Connected Indoor Units Trade Condensing Unit Price

3/4 1 3/8 375~975 64

3/4 1 3/8 400~1040 64

3/4 1 3/8 425~1105 64

3/4 1 5/8 450~1170 64

£16,600.00

£17,330.00

£18,830.00

£19,826.00

*The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrifgerant temperature control operation).

Please contact your local sales office regarding VRV IV-Q warranty and installation.

RXYQQ-T (38 to 42 HP)

VRV IV-Q Condensing Unit – Heat Pump Outdoor Units

RXYQQ38T RXYQQ8T

Capacity EER ESEER COP Dimensions

Weight Air Flow Rate External Static Pressure Electrical Details

Refrigerant Circuit

Sound Pressure Sound Power Piping Limits Piping Connections

Nominal Cooling Nominal Heating

kW kW

Height Width Depth

mm mm mm kg m3/sec Pa Phase /Hz / V amps amps amps

High Power Supply Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge

Maximum Length Maximum Vertical Rise Liquid Gas

Capacity Index Limit Maximum Number of Connected Indoor Units Trade Condensing Unit Price

kg kg dBA dBA m m inches inches

RXYQQ40T

RXYQQ42T

RXYQQ10T RXYQQ20T RXYQQ10T RXYQQ12T RXYQQ18T RXYQQ10T RXYQQ16T

1685 930 765 187 2.10 78

106.00 120.00 3.42 6.36* 4.01 1685 930 765 194 2.92 78

3/4 1 5/8 475~1235 64

112.00 125.00 3.61 6.74* 4.05 1685 930 765 194 3.08 78 3ph / 50 / 400 43.7 111 32 R410a 6.3 data book 61 81 120 50 3/4 1 5/8 500~1300 64

20

44.3 111 25

50

25

5.2

6.0

11.8

6.0

58 78

58 79

66 88

58 79

£21,786.00

£22,148.00

1685 1240 765 314 4.35 78

1685 930 765 194 2.92 78

RXYQQ16T

1685 930 765 194 2.92 78

118.00 132.00 3.54 6.65* 4.00 1685 1240 765 305 3.88 78

1685 1240 765 305 3.88 78

40

25

46.2 122 40

40

11.7

6.0

10.4

10.4

65 86

58 79

64 86

64 86

1685 1240 765 314 4.18 78

3/4 1 5/8 525~1365 64 £22,878.00

*The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrifgerant temperature control operation).

Please contact your local sales office regarding VRV IV-Q warranty and installation. Price List 2015

75


RQCEQ-P3 (28.0 to 45.0 kW)

VRV III-Q Condensing Unit – Heat Recovery Outdoor Units

RQCEQ280P3 RQEQ140P3

Capacity

VRV

Dimensions

Weight Air Flow Rate External Static Pressure Electrical Details

Refrigerant Circuit

Sound Pressure Piping Limits Piping Connections

Nominal Cooling Nominal Heating Height Width Depth

High Power Supply

Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge Maximum Length Maximum Vertical Rise Liquid Gas

kW kW mm mm mm kg m3/sec Pa Phase Hz V amps amps amps kg kg dBA m m inches inches

RQCEQ360P3

RQEQ140P3

RQEQ180P3

28.00 32.00 1680 635 765 175 1.58

RQCEQ460P3

RQEQ180P3

RQEQ140P3

RQEQ140P3

36.00 40.00 1680 635 765 175 1.58

1680 635 765 175 1.58

1680 635 765 175 1.58

78

RQEQ180P3

45.00 52.00 1680 635 765 175 1.58 78

1680 635 765 175 1.58

78

1680 635 765 175 1.58

3ph 50 400 5.5+5.5 4

8.0+8.0 4

15

15

20

10.3

10.3

10.6

54

58

54

20 R410a 10.6 data book 58

15

5.5+5.5+8.0 4 15

20

10.3

10.3

10.6

54

54 120

58

120

120

3/8 7/8 125~325 16

1/2 1 162.5~422.5 20

1/2 1 1/8 200~520 26

£6,570.00

£8,450.00

£10,795.00

50

Capacity Index Limit Maximum Number of Connected Indoor Units Trade Condensing Unit Price

Please see note on page 78 regarding VRV III-Q warranty, and contact your local sales office for more information on VRV III-Q installation.

RQCEQ-P3 (50.0 to 63.6 kW)

VRV III-Q Condensing Unit – Heat Recovery Outdoor Units

RQCEQ500P3

RQCEQ540P3

RQCEQ636P3

RQEQ140P3 RQEQ180P3 RQEQ180P3 RQEQ180P3 RQEQ180P3 RQEQ180P3 RQEQ212P3 RQEQ212P3 RQEQ212P3 Capacity Dimensions

Weight Air Flow Rate Electrical Details

Refrigerant Circuit

Sound Pressure Piping Limits Piping Connections

Nominal Cooling Nominal Heating Height Width Depth

Power Supply

Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge Maximum Length Maximum Vertical Rise Liquid Gas Discharge Oil Equalising

kW kW mm mm mm kg m3/sec Phase Hz V amps amps amps kg kg dBA m m inches inches inches inches

Capacity Index Limit Maximum Number of Connected Indoor Units Trade Condensing Unit Price

1680 635 765 175 1.58

50.00 56.00 1680 635 765 175 1.58

5/8 1 1/8 7/8 225~585 29

54.00 60.00 1680 635 765 175 1.58 3ph 50 400 8.0+8.0+8.0 4 20 R410a 11 data book 58 120 50 5/8 1 1/8 7/8 250~650 33

15

5.5+8.0+8.0 4 20

20

20

10

11

11

11

54

58

58

58

£11,735.00

£12,675.00

1680 635 765 175 1.58

1680 635 765 175 1.58

1680 635 765 179 1.83

63.60 67.20 1680 635 765 179 1.83

1680 635 765 179 1.83

20

20

11.5+11.5+11.5 4 20

20

11

11

11

11

58

60

60

60

1680 635 765 175 1.58

5/8 1 1/8 1 275~715 36 £14,937.00

Please see note on page 78 regarding VRV III-Q warranty, and contact your local sales office for more information on VRV III-Q installation.

76

Residential, Commercial and Industrial


RQCEQ-P3 (71.2 to 74.4 kW)

VRV III-Q Condensing Unit – Heat Recovery RQCEQ712P3 RQEQ140P3 Capacity Dimensions

Weight Air Flow Rate Electrical Details

Refrigerant Circuit

Sound Pressure Piping Limits Piping Connections

Nominal Cooling Nominal Heating Height Width Depth

Power Supply

Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge Maximum Length Maximum Vertical Rise Liquid Gas Discharge Oil Equalising

kW kW mm mm mm kg m3/sec Phase Hz V amps amps amps

RQEQ180P3

RQEQ180P3

RQCEQ744P3 RQEQ212P3

RQEQ140P3

RQEQ180P3

71.20 78.40 1680 635 765 175 1.58

1680 635 765 175 1.58

RQEQ212P3

RQEQ212P3

74.40 80.80 1680 635 765 175 1.58

1680 635 765 179 1.83

1680 635 765 175 1.58

1680 635 765 175 1.58

1680 635 765 179 1.83

1680 635 765 179 1.83

VRV

Outdoor Units

3ph 50 400

15

5.5+8.0+8.0+11.5 4 20 20

20

15

5.5+8.0+11.5+11.5 4 20 20

20

R410a kg kg dBA m m inches inches inches inches

10.3

10.6

10.6

11.2

10.3

10.6

11.2

11.2

54

58

60

60

data book 54

58

58

60 120 50

5/8 1 1/8 1 300~780 40

3/4 1 3/8 1 325~845 43

£16,714.00

£17,468.00

Capacity Index Limit Maximum Number of Connected Indoor Units Trade Condensing Unit Price

Please see note on page 78 regarding VRV III-Q warranty, and contact your local sales office for more information on VRV III-Q installation.

RQCEQ-P3 (81.6 to 84.8 kW)

VRV III-Q Condensing Unit – Heat Recovery Outdoor Units

RQCEQ816P3 RQEQ180P3

Capacity Dimensions

Weight Air Flow Rate Electrical Details

Refrigerant Circuit

Sound Pressure Piping Limits Piping Connections

Nominal Cooling Nominal Heating Height Width Depth

Power Supply

Running Current Starting Current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge Maximum Length Maximum Vertical Rise Liquid Gas Discharge Oil Equalising

Capacity Index Limit Maximum Number of Connected Indoor Units Trade Condensing Unit Price

kW kW mm mm mm kg m3/sec Phase Hz V amps amps amps

RQEQ212P3

RQEQ212P3

RQCEQ848P3 RQEQ212P3

RQEQ212P3

RQEQ212P3

81.60 87.20 1680 635 765 175 1.58

1680 635 765 179 1.83

RQEQ212P3

RQEQ212P3

84.80 89.60 1680 635 765 179 1.83

1680 635 765 179 1.83

1680 635 765 179 1.83

1680 635 765 179 1.83

1680 635 765 179 1.83

1680 635 765 179 1.83

3ph 50 400

20

8.0+11.5+11.5+11.5 4 20 20

20

20

11.5+11.5+11.5+11.5 4 20 20

20

R410a kg kg dBA m m inches inches inches inches

10.6

11.2

11.2

11.2

11.2

11.2

11.2

11.2

60

60

60

60

data book 58

60

60

60 120 50

3/4 1 3/8 1 1/8 350~910 47

3/4 1 3/8 1 1/8 375~975 50

£19,162.00

£19,916.00

Please see note on page 78 regarding VRV III-Q warranty, and contact your local sales office for more information on VRV III-Q installation.

Price List 2015

77


NEW SIMPLIFIED PROCESS

VRV-Q Warranty

VRV

Warranty and Site Services The warranty for VRV-Q systems operates under different conditions to our standard warranty. To ensure complete suitability of the existing site, a choice of optional warranty and special site services packages are available from Daikin Airconditioning UK Ltd. These choices will ensure the VRV-Q system is designed and commissioned to provide the client with complete ‘peace of mind’ operation. The choices include: a) Pre-order checks on the existing pipework and fan coils installed on the clients’ site to ensure suitability for VRV-Q installation b) Commissioning of the new VRV-Q installation to ensure correct and efficient operation Warranty options for 3 or 5 years are available depending on the qualification criteria and the type of system being installed. Commissioning Log Books should be available for inspection by Daikin Airconditioning UK Ltd if required. The tables below provide an overview of the choices, with a brief description on page 79. For full details please contact your local sales office.

VRV-Q Warranty Choices 1. VRV-Q combined with new fan coil units Warranty Package Level

For Site with New Fan Coils non D1/D1+

Condensing Unit Warranty Period Fan Coil Unit Warranty Period Site Pre-Order Inspection Commissioning

D1/D1+

3 Years 5 Years 3 Years 5 Years By trained approved engineer (1) OR by Daikin Airconditioning UK Ltd (additional cost) By approved engineer (1) (subsequent projects) OR by Daikin Airconditioning UK Ltd (additional cost)

2. VRV-Q combined with existing fan coil units Warranty Package Level

For Site with Existing Fan Coils non D1/D1+

Condensing Unit Warranty Period Existing Fan Coil Unit Warranty Period Site Pre-Order Inspection Commissioning

D1/D1+

3 Years 5 Years 0 Years 0 Years By trained approved engineer (1) (2) OR by Daikin Airconditioning UK Ltd (additional cost) By approved engineer (1) (subsequent projects) OR by Daikin Airconditioning UK Ltd (additional cost)

Notes: Approved engineer to sign commissioning report and be able to identify DAUK official training programme attended, SE19 VRV-Q required Trained approved engineer to collect 2 hours of data per system from the service checker for assessment

(1) (2)

Daikin Support Options Site pre-order inspection per system* Site pre-inspection (existing fan coils) including 2 hour service checker analysis per system* Daikin commissioning per system* Daikin full day commissioning assistance

Cost

Code

£175.00 £285.00

UK.SFV/N/INSP UK.SFV/E/INSP

£400.00 £585.00

UK.SFV/SYCOMM UK.SFV/FULLCOMM

*System is defined as a maximum of 3 connected condensers. All prices shown are Net. No further discount can be applied.

78

Residential, Commercial and Industrial


VRV

VRV-Q Warranty Detail Approved engineer An approved engineer is an engineer who: 1. Is suitably registered in accordance with F-gas regulations; 2. Has successfully completed a Daikin Airconditioning UK Ltd VRV Air Cooled installation and commissioning course within the last 3 years. 3. Has completed SE19 VRV-Q course in the past 3 years.

• Check status of the existing indoor units – necessary if the existing units are to be reused • Check filter condition • Check coil condition • Check fan motor operation – select fan only and check for air movement and for unusual noise and vibration

Net price Net price, exclusive of VAT and subject to our standard terms and conditions. No other discounts are applicable. Prices shown for site pre-order inspection and commissioning are for work undertaken during normal working hours between 09:00 and 17:30. Any request for attendance to site out of these hours is subject to additional charges.

• Installed pipework details – necessary to check compliance with the manufacturer’s specification and assess install quality. This would highlight any required rectification prior to the installation of the new system • Provide as installed pipework diagrams. If not available, provide as installed pipe work schematics from information gathered on site • Check the distance from the outdoor to the farthest indoor along the pipe work route • Check the distance from the first Refnet fitting to the farthest indoor unit • Check the height difference between the outdoor and the lowest indoor when the outdoor is situated above the indoor units or height difference between the outdoor and the highest indoor if the outdoor is situated below the indoor units • Check the height difference between the highest and the lowest indoor connected to the same system • Provide the lengths of all installed pipe sizes • Check the installation position and angle of the Refnet Joints • Check the condition of the pipe insulation • Check the adequacy of the existing pipe supports

Warranty To activate the warranty the Daikin Airconditioning UK Ltd VRV Commissioning Log Book will need to be fully completed and submitted to Daikin Airconditioning UK Ltd FQS department for checking. Upon receipt and validation that all required details are provided and satisfactory, Daikin Airconditioning UK Ltd will issue a confirmation letter that the warranty is activated. Where Daikin Airconditioning UK Ltd will complete the commissioning we will provide a copy of the Commissioning Log Book to the installation contractor. Except where mentioned above, our standard warranty conditions will apply. If none of the packaged options are chosen, then the warranty will be limited to a standard 12 month parts only cover. Site pre-order inspection Where required, Daikin Airconditioning UK Ltd will attend the site to check the suitability of the existing equipment and pipework for connection to VRV-Q. Where it is not possible to check operation or equipment condition, this will also be highlighted in the final report, and appropriate recommendations made. If an approved engineer carries out the site inspection, then a Daikin Airconditioning UK Ltd supplied form shall be completed and submitted to our FQS department for checking and approval prior to any order being accepted. The pre-order site inspection will include for the following items. • Existing system(s) capacity – necessary to estimate required system load for the new system • Record all the model numbers and the serial numbers for the indoor and the outdoor units and indicate actual installed system combinations

• Installed communication and control wiring – necessary to check compliance with the manufacturer’s specification, suitability for the new system and suitability for new controls specification • Check sizes and type of the interconnecting communication cables between indoor units, outdoor units and any central control systems • Check the separation between the power wiring and the installed controls wiring • Power wiring to the outdoor units – necessary to check suitability for the new outdoor units • Check supply voltage • Check number of outlets available adjacent to the outdoor units compound • Check fuse/MCB sizes and types • Check status of the isolators

Price List 2015

79


VRV

VRV-Q Warranty Detail • System health checks – it is important to know if the existing systems are operating to their optimum. If there are issues which may affect the new installation they need to identified and rectified before installation of the new system. A comprehensive list of the operating data can be collected by connecting a VRV Checker to each system and recording a minimum of one hour operation data for analysis. This data should be sent back to Daikin Airconditioning UK Ltd FQS department for analysis • Operate the whole system in cooling for ½ hour and in heating for ½ hour to collect representative data • Send data to Daikin Airconditioning UK Ltd FQS department for analysis • System history check – although the new VRV-Q system is designed to re-use existing pipework and in some cases existing indoor units it is still necessary to know the existing systems operational history to judge its integrity for the new application • Check for presence of leak protection dye and acid level – use total test kit • Ensure that no Acid Away chemical has ever been added to the system refrigerant charge • Existing system controls – investigate currently installed local controls, centralised controls and connection to the third party systems. This is particularly necessary if any existing controls are planned to be re-used Commissioning Dependant on the requirement, either an approved engineer or Daikin Airconditioning UK Ltd will provide system commissioning on the completed installation. As mentioned in the warranty section above, a completed log book will need to be submitted to activate the warranty Commissioning where not provided by Daikin Airconditioning UK Ltd, can only be completed by an approved engineer Where Daikin Airconditioning UK Ltd provides commissioning as part of the package this shall include: • Check installation of new units – ensure new piping is installed correct to Daikin specification • Check power supplies – local isolators, MCB rating • Fill in model number data, serial numbers etc. to commissioning log book • Initialise VRV System and ensure all units communicate • Set up additional control systems – ITC, Bacnet and provide demonstration • Charge additional refrigerant • Perform “Test” operation – including “Automatic” charging function • Connect service checker and monitor operation – Cool>Heat>Heat Recovery • Complete Commissioning Log Book • Provide additional comments and recommendations if necessary • Leave operation set as required by client Prior to our site attendance the following shall be completed: • All communication wiring is complete and terminated correctly • All electrical work is complete and correct (supply wiring type and size – Breaker size correct) • All systems piping has been pressure tested to 33 Bar • All systems piping has been evacuated to < 5 Torr • All systems piping has been measured and is available for our information • Sufficient additional refrigerant is available on the day Any other works other than those detailed above are excluded.

80

Residential, Commercial and Industrial

DNSS (Daikin Network Service System) Where Daikin Airconditioning UK Ltd provide DNSS this shall include the following items: • Commissioning of DNSS system (on-site service) • GPRS router and SIM (this will be property of Daikin Airconditioning UK Ltd) • Remote energy saving service • 24/7 monitoring of VRV operating data • Instant notification of system malfunction (email) 7 days a week • Malfunction prediction service (during office hours 09.00 - 17.30) • Bi-annual energy saving report indicating electricity cost saving and reduction in CO2 emissions • Recommendations to improve operating settings • Issue of a DNSS user pack All of the above will be provided for the warranty period of the VRV (either 3 or 5 years) depending on the package selected. Prior to our site attendance the following shall be completed: • A device compatible with DNSS is installed on site – Daikin Intelligent Manager, Daikin Intelligent Touch Controller or Daikin LC controller. (Not included in the price of the monitoring package) • All electrical work is complete and correct (supply wiring type and size – Breaker size correct) also F1/F2 communications are installed • A full set of as installed drawings are available – indicating system configurations, installation locations and room references • A power source is installed for the GPRS modem near the control device – This can be powered from a standard socket • A connection to the internet is available – for areas where there is poor GPRS coverage a LAN or analogue phone connection must be installed near the control device. (Installation and rental costs are not included in the price of the monitoring package) • Full access must be made available to the VRV equipment and if any access equipment is required Daikin UK must be informed prior to the site visit • A list of contacts must be issued to Daikin Airconditioning UK Ltd (these are the contacts that should be e-mailed or telephoned in the event of a malfunction or error with the air conditioning system). If these change in the future, information will be given in the user pack for how to notify Daikin Airconditioning UK Ltd of the changes This is an extract from the Daikin publication “Warranty and Site Services Package for VRV-Q”. Please contact your local sales office to receive a copy and obtain further information.


NEW NEW

Mini Building Management System Mini Building Management System

Check on Check on https://www.youtube.com/ https://www.youtube.com/ DaikinEurope DaikinEurope

VRV Accessories DCM601A51 DCM601A51

with with full full integration integration across across all all product product pillars pillars

Price competitive mini BMS Price competitive mini BMS Cross-pillar integration of Daikin products Cross-pillar integration of Daikin products Integration of third party equipment Integration of third party equipment VRV

Mini BMS

• • • • • •

System overview System overview

System overview

Web Access Web Access

Internet Extranet Internet LAN Extranet 3G LAN http interface 3G http interface

Integration of third Integration of third party equiqment party equiqment

Full control of Daikin Full HVAC-R control of Daikin portfolio HVAC-R portfolio DCM601A51 DCM601A51

ITM plus adaptor line ITM plus adaptor line

Di/Pi line Di/Pi200m line Max. Max. 200m

Fire alarm Fire alarm

Di/Pi port Di/Pi port

kWh meter kWh meter

Max. 7 adapters Max. 7 adapters

DCM601A52 DCM601A52

Direct plug & play connection! Direct plug & play connection!

Lighting Lighting

Fan Fan

Pump Pump

Sensor Sensor

air curtain, hydrobox, hydrobox, air handling units air handling units

Referigeration Referigeration

indoor units, indoor units, air curtain,

Chillers Chillers andand AHU AHU

WAGO WAGO interface interface I/OI/O module module I/OI/O module module

BACnet BACnet protocol protocol

FanFan coilcoil units units

Split Split

Multi state objects Multi state objects

Elevator Elevator

Air handling unit Air handling unit

Alarm Alarm

224 224 Price List 2015 ECPEN15-200.indd 224

81 12/02/15 11:47


NEW Mini Building Management System Mini NEW MiniBuilding BuildingManagement ManagementSystem System NEW Mini Building Management System NEW Mini Building Management System NEW

Mini Building Management System

User friendly User friendliness User Userfriendliness friendliness >User Intuitive user interface friendliness Intuitive user interface V isual layout view and direct access to indoor › ››> Intuitive user User friendliness Intuitive userinterface interface

lay out view and direct access indoor unit unitlay main functions › ››Visual view and › Visual Intuitive user interface Visual layout out view anddirect directaccess accesstoto toindoor indoorunit unit funtions > A ll functions direct accessible via touch screen main funtions › main Intuitive user interface Visual lay out view and direct access to indoor unit main funtions functions direct accessible via touch screen or viafuntions web interface › ››All functions direct touch › All Visual lay out viewaccessible and directvia access toscreen indoor main All functions direct accessible via touch screen unit via web interface or via web interface main funtions › or All functions direct accessible via touch screen or via web interface › All functions direct accessible via touch screen or via web interface

Smart energy management energy management Smart management or viaenergy web interface Smart energy management Smart energy management Monitoring use plan Monitoring ifenergy energy use isaccording according plan › ››> Monitoring if ififenergy use isis toto plan Smart energy management Monitoring energy use isaccording according toto plan

detect origins waste Helps detect origins ofenergy waste › ››> Helps toto detect origins ofof waste › Helps Monitoring if energy use isenergy according to plan Helps toto detect origins ofenergy energy waste schedules guarantee correct operation P owerful schedules guarantee correct operation › ››> Powerful schedules guarantee correct › Powerful Monitoring if energy use is according to plan Helps to detect origins of energy waste Powerful schedules guarantee correctoperation operation the year throughout the yearguarantee throughout the year › throughout Helps to detect origins of energy wasteoperation Powerful schedules correct throughout the year energy interlocking A/C operation with other Save energy by interlocking operation › ››> Save energy byby interlocking A/C operation with › Save Powerful schedules guarantee correct operation throughout the year Save energy by interlocking A/CA/C operation withother other equiment such as heating with other equipment such as heating equiment such as heating throughout the year › equiment Save energy by as interlocking such heating A/C operation with other › Save energysuch by interlocking equiment as heating A/C operation with other

Flexibility Flexibility equiment such as heating Flexibility Flexibility Flexibility Cross-pillar integration (heating, conditioning, › ›Cross-pillar NEW NEW Cross-pillarintegration integration(heating, (heating,airair airconditioning, conditioning, NEW ›Flexibility

systems, refrigeration, handling units) > NEWsystems, Cross-pillar integration applied refrigeration, airair handling units) › applied Cross-pillar integration (heating, air conditioning, applied systems, refrigeration, air(heating, handling units) ››BACnet protocol for 3rd party products integration air conditioning, applied systems, refrigeration, protocol for 3rd products integration › BACnet Cross-pillar integration (heating, conditioning, applied systems, refrigeration, airair handling units) BACnet protocol for 3rdparty party products integration ››I/O for integration of equipment such lights, air handling units) for integration of such asas applied systems, refrigeration, air handling units) › I/O BACnet protocol for 3rd party products integration I/O for integration ofequipment equipment such aslights, lights, on WAGO >› pumps… NEW BACnet protocol for 3rd party on modules BACnet protocol for 3rd party products I/O for integration ofmodules equipment such products asintegration lights, pumps… onWAGO WAGO modules NEW pumps… concept for small to large applications integration › ››Modular concept for small to large › Modular I/O for integration of equipment such as lights, pumps… on WAGO modules Modular concept for small to largeapplications applications up to 512 indoor unit groups via one ITM I/O forup integration ofmodules equipment as lights, › ››> Control to unit groups via ITM pumps… on WAGO › Control Modular concept for small largesuch applications Control up to512 512indoor indoor unitto groups viaone one ITM and combine multiple ITM via the web interface pumps… on WAGO modules and combine multiple ITM via the web interface › and Modular concept for small to groups large applications Control up tomultiple 512 indoor viainterface one ITM combine ITMunit via the web >› Control Modular for small togroups large applications upconcept to 512 indoor unit viainterface one ITM and combine multiple ITM via the web Easy servicing and commissioning > C ontrol up to 512 indoor unit groups one ITM Easy servicing and commissioning and combine multiple ITM via the web interface Easy servicing and commissioningvia and servicing combine multiple ITM via the web interface Easy and commissioning Remote refrigerant containment check preventing › ››Remote refrigerant containment check Easy servicing and commissioning Remote refrigerant containment checkpreventing preventing on site visit on site visit › on Remote refrigerant containment check preventing site visit troubleshooting servicing andcontainment commissioning › ››Easy Simplifi eded troubleshooting › Simplifi Remote refrigerant check preventing on site visit Simplifi ed troubleshooting time on commissioning › ››Save time on commissioning on site visit › Save Simplifi ed troubleshooting Save time on commissioning to the pre-commissioning tool > Remote refrigerant containment check thanks to the pre-commissioning tool › thanks Simplifi troubleshooting Save time on commissioning thanks toed the pre-commissioning tool Auto registration of indoor units preventing on site visit › ››Auto registration of indoor units › Auto Save time on commissioning thanks to the pre-commissioning registration of indoor units tool >› thanks Simplified troubleshooting to the pre-commissioning Auto registration of indoor units tool >› Auto Save registration time on commissioning of indoor unitsthanks to the pre-commissioning tool > Auto registration of indoor units

Plug play Plug Plug&& &play play Plug & play Plug & play

NEW NEW NEW NEW› NEW NEW›

Functions overview Functions Functionsoverview overview Functions overview Functions overview Functions overview Languages Management Languages Languages

82

Residential,

Split Split Split

Fancoils coils Fan Fan coils

Chillersand andAHU AHU Refrigeration Refrigeration Chillers Chillers and AHU Refrigeration

Split

Fan coils

Chillers and AHU

Refrigeration

Split

Fan coils

Chillers and AHU

Refrigeration

Flexibilityininsize size Flexibility Flexibility in size From6464upuptoto∞∞number number From Flexibility in number size From 64 up to ∞ ofgroups groups of FromFlexibility 64ofup to in number groups ∞size From 64 of upgroups to ∞ number of groups

Control Management Management Management

Control Control Control

Connectable to Connectable Connectabletoto

Connectable to

English Webaccess access Individualcontrol control - DXSplit, Split,Sky SkyAir, Air, VRV › ›English › ›Web › ›Individual -Connectable DX VRV > DX Split, Sky Air, VRV › Languages English > Web access › Management Web access > Individual control› Control Individual control - DX Split, Sky Air, to VRV French > Power Proportional› ›Power PowerProportional Proportional (2,560 groups) Chillers (via POL638.70 controller) › ›French (2,560 groups) Chillers (via POL638.70 > Chillers (via POL638.70 > Schedule setting (weekly Control Connectable › French English › Power Web access › (2,560 Individual control DXcontroller) Split, Sky Air,to VRVcontroller) › Languages › Management Proportional groups) - -Chillers (via POL638.70 controller) German Distribution (option) Distribution Distribution(option) (option) ›Schedule Schedulesetting setting (WeeklyDaikin - DaikinAHU AHU › ›German › (Weekly Daikin NEW NEW > AHU schedule, yearly calender, NEW English ›› Distribution Web access Individual control(Weekly NEW ---Daikin DX Split, SkyPOL638.70 Air, VRV controller) French Power Proportional (2,560 groups) Chillers (via › ›› German (option) › › Schedule setting AHU Italian > Operational history› ›Operational Operationalhistory history schedule,yearly yearly calender, - Fancoils coils › ›Italian > calender, Fan coils NEW- Fan seasonal schedule)schedule, French Power Proportional (2,560 groups) Chillers (via POL638.70 controller) German Distribution (option) › schedule, Schedule setting (Weekly Daikin › ›› Italian › › Operational history yearly calender, ---Fan coilsAHU Spanish (malfunctions, operation seasonalschedule) schedule) - Daikin AlthermaFlex Flextype type (malfunctions, operation hours, > Daikin Altherma Flex type > Interlock control › ›Spanish seasonal Altherma (malfunctions, operation …)…) German Distribution (option) › seasonal Schedule setting (Weekly NEW- Daikin Daikin AHU Italian › (malfunctions, Operational historyhours, schedule, yearly calender, Fan coils › ›› Spanish schedule) ---Daikin Altherma Flex type operation hours, …) > LT and HT hydroboxes > Setpoint limitation hours, …) Dutch ›Interlock Interlockcontrol control - LTand andHTHThydroboxes hydroboxes ›Smart Smartenergy energy management › ›Dutch › LT › management Italian Operational schedule, yearly calender, Fan coils Spanish seasonalcontrol schedule) Daikin Altherma Flex type (malfunctions, operation hours, …) › ›› Dutch › Interlock ---LT and HT hydroboxes › › Smart energyhistory management > Air curtains > Temperature limit > Smart energy management Portuguese Setpointlimitation limitation - Aircurtains curtains - monitorif ifenergy energy useis is › ›Portuguese › ›Setpoint - Air -›monitor use Spanish seasonal schedule) Daikin Flex type operation Dutch Interlocklimitation control LT curtains and Altherma HT hydroboxes Smart energy management › ›› Portuguese › › Setpoint ---Air -(malfunctions, monitor if energy usehours, is …) > WAGO I/O, AO and PI I/O, – monitor if energy useaccording is Temperaturelimit limit - WAGO I/O,AO AOand andPIPI plan › ›Temperature - WAGO toto ›› Dutch Interlock LT HT AO hydroboxes › according Smart energy management Portuguese according to plan according Setpoint control limitation Airand curtains - monitor ifplan energy use is › ›› Temperature limit ---WAGO I/O, and PI to plan > NEW BACnet protocol BACnet protocol - detectorigins originsofofenergy energy System layout BACnet protocol detect System layout NEW NEW › Portuguese ›› Setpoint limitation Air curtains monitor iftoenergy use is Temperature limit WAGO I/O, AO and PI plan protocol --according detect origins of energy System NEW ---BACnet > WAGO Interface layout – detect origins of energy waste Uptoto2,560 2,560unit unitgroups groupscan can waste › ›Up › Temperature limit AO and PI according to plan BACnetI/O, protocol - detect origins of energy layout waste › System Up to 2,560 unit groups can NEW -- WAGO waste ›Setback Setbackfunction function becontrolled controlled WAGO Interface › be WAGO -waste detectfunction origins of energy System layout › be Upcontrolled to 2,560 unit groups can > Setback function › Setback WAGOInterface Interface NEW - BACnet protocol Slidingtemperature temperature (ITMplus plusIntegrator Integrator+temperature +7 iPU 7 iPU Modularintegration integrationofof3rd 3rd › ›Sliding (ITM › ›Modular > Sliding waste › (ITM Up to 2,560 unit groups can Setback function be controlled › › Sliding temperature plus Integrator + 7 iPU › WAGO Modular Interface integration of 3rd (incl.iTM iTMadaptor) adaptor) partyequipment equipment (incl. party ›› Setback function be controlled WAGO Interface Sliding temperature (ITM plusadaptor) Integrator + 7 iPU › party Modular integration of 3rd (incl. iTM equipment Ethernet TCPIP - WAGOcoupler coupler(interface (interface › ›Ethernet TCPIP -› WAGO › Sliding temperature (ITM Integrator integration of 3rd (incl.plus iTM adaptor) + 7 iPU party › Ethernet TCPIP -Modular WAGOequipment coupler (interface betweenWAGO WAGOand andModbus) Modbus) between iTM TCPIP adaptor) party equipment › (incl. Ethernet - WAGO coupler (interface between WAGO and Modbus) - Dimodule module - Di › Ethernet TCPIP WAGO coupler (interface between WAGO and Modbus) - Di module - Domodule module - Do Commercial and Industrial WAGO and Modbus) -Do Di module -between - Aimodule module - Ai Di module Do module ---Ai module - Thermistormodule module - Thermistor

Control Systems Control Control Systems Systems Control Systems Control Systems

VRV

NEW


BS-Q-A

VRV IV Branch Selector Boxes – Heat Recovery

BS1Q10,16,25A

Main Features:

BS4Q14A

BS6,8Q14A

BS10,12Q14A

VRV

The new VRV IV Heat Recovery series has a new range of BS boxes, which are designed to offer unrivalled flexibility – enabling you to install and adapt the systems in as little time, effort and cost as possible.

BS16Q14A

> Unlimited unused ports > Smaller, lighter and quieter than comparable products > Fan coils up to 140 class can be attached to a single port During 2015 some systems will be moving from using VRV III BS boxes to VRV IV BS box compatibility. VRV IV Air cooled systems all use VRV IV boxes however particular care should be taken with RWEYQ-T Water cooled and VRV-Q Heat Recovery systems. Please check with Daikin UK to ensure that you are considering using the correct BS unit series for your project. Single Boxes for VRV IV Heat Recovery (REYQ*T)

Single Boxes BS1Q10A

Dimensions Weight Total Indoor Capacity Number of Fan Coil Units Electrical Details

HxWxD

Piping Limits Piping Connections Indoor Piping Connections Outdoor

Power Supply Power Input Fuse Rating Level Difference Maximum Length Liquid Gas Liquid Suction Discharge

mm kg

BS1Q16A

12 15 ~ 100 6

Phase kW amps m m inches inches inches inches inches

3/8 5/8 3/8 5/8 1/2

3/8 5/8 3/8 5/8 1/2

3/8 7/8 3/8 7/8 3/4

£337.00

£372.00

£427.00

Multi Boxes for VRV IV Heat Recovery (REYQ*T)

Multi Boxes BS4Q14AV1

Trade Accessory Price

15 161 ~ 250 8

Data Book

Trade Accessory Price

Dimensions HxWxD Weight Branches per box Capacity index of each branch Number of Fan Coil Units per branch Total Indoor Capacity Index Total number of Fan Coil units per box Electrical Details Power Supply Power Input Fuse Rating Piping Limits Level Difference Maximum Length Piping Connections Indoor Liquid Gas Piping Connections Outdoor Liquid Suction Discharge

BS1Q25A

207 x 388 x 326 12 100 ~ 160 8 1 Phase, 220 - 240V, 50Hz 0.005 15

mm kg

298 x 370 x 430 17 4

BS6Q14AV1

BS8Q14AV1

BS10Q14AV1

298 x 580 x 430 24 6

BS12Q14AV1

298 x 820 x 430 26 8

35 10

BS16Q14AV1

38 12

298 x 1060 x 430 50 16

60

64

0.129 15

0.172 15

140 or less 5 per branch

Phase kW amps m m inches inches inches inches inches

400 or less 20

600 or less 30

0.043 15

0.064 15

750 or less 40 50 1 Phase, 220 - 240V, 50Hz 0.086 0.107 15 15 Data Book

3/8 5/8 3/8 7/8 3/4

3/8 5/8 1/2 1 1/8 3/4

3/8 5/8 1/2 1 1/8 3/4

3/8 5/8 5/8 1 1/8 1 1/8

3/8 5/8 5/8 1 1/8 1 1/8

3/8 5/8 3/4 1 3/8 1 1/8

£1,550.00

£2,123.00

£2,792.00

£3,357.00

£4,114.00

£5,008.00

Accessories: Accessory Ref

Description

Trade Price

KHRP26A250T KHFP26M224 KHFP26A100C

Junction pipe kit to link two Multi BS ports to connect 20 and 25kW fan coils Stop valve kit for multi BS box future expansion without refrigerant recovery Pipe closing kit for unused ports

£280.00 £92.00 £45.00

Price List 2015

83


RXYSQ, RYYQ, REYQ, RWEYQ

VRV Condensing Unit – Refnet Joints For Outdoor Units

2-Pipe System Refrigerant Sizing between Refnet Joints and Indoor/Outdoor Units RXYSQ / RYYQ / RWEYQ Total Capacity of Indoor Units

VRV

RXYQ5P / RXYSCQ / RXYSQ4-6PA RYYQ8-54T / RWEYQ-T

Liquid Pipe

Suction Pipe

Below 62.5

1/4

1/2

KHRQ22M20T

£29.00

62.5 to 162.5

3/8

5/8

KHRQ22M20T

£29.00

KHRQ22M20T KHRQ22M20T KHRQ22M29T9 KHRQ22M64T KHRQ22M64T KHRQ22M75T KHRQ22M29H KHRQ22M64H KHRQ22M75H BHFQ22P1007 BHFQ22P1517 BHFP22P36C BHFP22P54C

£29.00 £29.00 £36.00 £38.00 £38.00 £48.00 £114.00 £139.00 £182.00 £78.00 £153.00 £96.00 £191.00

Below 150 150 to below 200 200 to below 290 290 to below 420 420 to 639 640 and above

3/8 5/8 3/8 3/4 3/8 7/8 1/2 1 1/8 5/8 1 1/8 Please contact your local sales office for selection

Refnet Header Refnet Header Refnet Header Condensing Unit Branch Kit - 2 Module RYYQ, RWEYQ Condensing Unit Branch Kit - 3 Module RYYQ Condensing Unit Branch Kit - 2 Module RQYQ Condensing Unit Branch Kit - 3 Module RQYQ

For Outdoor Units

RWEYQ8-30T / REYQ-T

84

Trade Price

Refnet Selection

3-Pipe System Refrigerant Sizing between Refnet Joints and Indoor/Outdoor Units REYQ / RWEYQ Total Capacity of Indoor Units

Liquid Pipe

Below 150 150 to below 200 200 to below 290 290 to below 420 420 to 639 640 and above

3/8 3/8 3/8 1/2 5/8

Discharge Pipe

1/2 5/8 3/4 3/4 1 1/8 Please contact your local sales office for selection Refnet Header Refnet Header Refnet Header Condensing Unit Branch Kit - 2 Module REYQ, RWEYQ Condensing Unit Branch Kit - 3 Module REYQ, RWEYQ Condensing Unit Branch Kit - 2 Module RQEQ Condensing Unit Branch Kit - 3 Module RQEQ Condensing Unit Branch Kit - 4 Module RQEQ

Residential, Commercial and Industrial

Trade Price

Suction Pipe

Refnet Selection

5/8 3/4 7/8 1 1/8 1 1/8

KHRQ23M20T KHRQ23M20T KHRQ23M29T9 KHRQ23M64T KHRQ23M64T KHRQ23M75T KHRQ23M29H KHRQ23M64H KHRQ23M75H BHFQ23P907 BHFQ23P1357 BHFP26P36C BHFP26P63C BHFP26P84C

£42.00 £42.00 £55.00 £58.00 £58.00 £72.00 £157.00 £190.00 £267.00 £145.00 £293.00 £164.00 £333.00 £442.00


VRV Accessories Remote Controllers (supplied loose) VRV Remote Control Options

Model

Description

Related Fan Coil

Trade Price

BRC1E52A

Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock

All

£76.00

BRC2E52C

Wired Simplified remote controller

All

£80.00

UK.BRC2E/CHROME/POL

Polished chrome simplified controller, recessed in wall

All

£180.00

UK.BRC2E/CHROME/BRU

Brushed chrome simplified controller, recessed in wall

All

£180.00

UK.BRC2E/BRA/POL

Polished brass simplified controller, recessed in wall

All

£180.00

BRC3E52C

Simplified Remote Controller (without heat/cool button)

All

£80.00

UK.BRC3E/CHROME/POL

Polished chrome simplified controller, recessed in wall (without heat/cool button)

All

£180.00

UK.BRC3E/CHROME/BRU

Brushed chrome simplified controller, recessed in wall (without heat/cool button)

All

£180.00

UK.BRC3E/BRA/POL

Polished brass simplified controller, recessed in wall (without heat/cool button)

All

£180.00

BRP7A51/UK.FB2

Digital input adaptor for Key card and Window switch contacts with programmable logic

For use with Simplified controllers

£85.00

BRC4C61

Wireless remote controller

FXKQ-MA

£135.00

BRC4C62

Wireless remote controller

FXDQ-M9 FXDQ-A, FXSQ-A, FXMQ-MA

£135.00

BRC4C65

Wireless remote controller

FXMQ-P7, FXLQ-P, FXNQ-A

£152.00

BRC7C58

Wireless remote controller

FXUQ-A

£152.00

BRC7C52

Wireless remote controller

FXCQ-A

£152.00

BRC7E618

Wireless remote controller

FXAQ-P

£135.00

BRC7F530W

Wireless remote controller for White Ceiling Decoration Panel

FXZQ-A + BYFQ60CW

£152.00

BRC7F530S

Wireless remote controller for Silver Ceiling Decoration Panel

FXZQ-A + BYFQ60CS

£152.00

BRC7EB530W

Wireless remote for Fully Flat Cassette Old Style Decoration Panel

FXZQ-A + BYFQ60B3

£152.00

BRC7FA532F

Wireless remote controller

FXFQ-A

£152.00

BRC7G53

Wireless remote controller

FXHQ-A

£152.00

NEW

VRV

Hard Wired Controllers

Infra Red controllers

Price List 2015

85


VRV Accessories Control and BMS Interfaces (supplied loose)

VRV

VRV Control and BMS Interfaces

NEW

KRP2A52

KRP4A53

RTD-NET

RTD-10

RTD-20

RTD-HO

KLIC-DI

Interface Method

System

Unit/Group

Unit/Group

Unit/Group

Unit/Group

Unit/Group

Unit/Group

System

System

System

Control Protocol

Daikin

Daikin

Modbus

Modbus

-

Modbus

Modbus

KNX

LONWorks

BACnet

Modbus

0-10 Volt control

-

-

-

-

4

4

-

-

-

-

-

4

4

-

-

4

4

-

-

-

-

-

On/Off

4

4

4

4

4

4

4

4

4

4

4

SetPoint

4

4

4

4

4

4

4

4

4

4

4

Operating Mode

4

4

4

4

4

4

4

4

4

4

4

Fan Speed

4

4

4

4

4

4

4

4

4

4

4

-

-

4

4

4

4

4

4

-

4

4 -

Resistance control

DMS504B51 DMS502A51

EKMBDXA

Control Functions

Louver Setting VAM Damper control

-

-

4

4

4

4

-

-

-

-

Control Prohibit / Restrict settings

-

-

4

4

4

4

4

-

4

4

4

Temperature SetPoint Limits

-

-

4

4

-

4

4

4

-

-

4

Scene Creation

-

-

-

-

-

-

-

4

-

-

-

4

4

4

4

-

4

4

4

4

4

4

Temperature Set Point

-

-

4

4

-

4

4

4

4

4

4

Operating Mode

-

-

4

4

-

4

4

4

4

4

4

Thermostat On

-

-

4

4

4

4

4

-

-

4

4

Fan Operation

-

-

4

4

-

4

4

4

-

4

4

Louvre Position

-

-

4

4

-

4

4

4

-

4

4

4

4

4

Monitoring Functions On/Off

4

4

4

4

4

4

4

4

Fault Code

-

-

4

4

-

4

4

4

4

4

4

Remote Controller temperature

-

-

4

4

-

4

4

-

4

4

4

Remote Controller Mode

-

-

4

4

-

4

4

-

-

4

4

Number of Units

-

-

4

4

-

4

4

-

-

4

4

Return Air Temperature (Average/Min/Max)

-

-

4

4

-

4

4

-

4

4

-

Coil In/Out temperature

-

-

4

4

-

4

4

-

-

-

-

Filter Alarm

-

-

4

4

-

4

4

4

4

4

4

Defrost Operation

-

-

4

4

4

4

4

-

-

-

4

Temperature Set Back

-

-

-

-

-

4

4

-

-

-

-

Temperature Setpoint Limitation

-

-

-

4

4

4

4

-

-

-

-

Key Card + Window Contact

-

-

-

-

-

4

4

-

-

-

-

Heating Interlock

-

-

-

4

4

-

-

-

-

-

-

Run / Standby

-

-

-

4

4

-

-

-

-

-

-

Interface

KRP2A52

KRP4A53

RTD-NET

RTD-10

RTD-20

RTD-HO

KLIC-DI

DMS504B51

DMS502A51

EKMBDXA

Trade Price

£177.00

£67.00

£165.00

£210.00

£226.00

POA

£185.00

POA

POA

POA

Mounting Box (FXFQ, FXCQ, FXZQ, FXUQ, FXHQ, FXDQ, FXAQ)

UK.FB2

UK.FB2

UK.FB2

UK.FB2

UK.FB2

UK.FB2

-

-

-

-

Trade Price

£25.00

Fault

Integral Functions (BMS system not req’d)

Prices

Associated Items

£25.00

£25.00

£25.00

£25.00

£25.00

-

-

-

-

Expansion PCB for additional unit connection

-

-

-

-

-

-

-

DAM411B51

-

Trade Price

-

-

-

-

-

-

-

POA

86

Residential, Commercial and Industrial


VRV Accessories RTD-20 Control Panels Control Panels have been developed to allow easy installation of the RTD-20 into end-user premises. A typical application would require 1 RTD-20 per zone within a building. The control panels are pre-configured for up-to 8 different zones, making installation and wiring much simpler for the installer. Model

Description

Trade Price

UK.ENC/RTD-20X1

Enclosure for RTD20 x 1

£300.54

UK.ENC/RTD-20X2

Enclosure for RTD-20 x 2

£765.54

UK.ENC/RTD-20X3

Enclosure for RTD-20 x 3

£1,010.81

UK.ENC/RTD-20X4

Enclosure for RTD-20 x 4

£1,256.08

UK.ENC/RTD-20X5

Enclosure for RTD-20 x 5

£1,576.35

UK.ENC/RTD-20X6

Enclosure for RTD-20 x 6

£1,826.62

UK.ENC/RTD-20X7

Enclosure for RTD-20 x 7

£2,071.89

UK.ENC/RTD-20X8

Enclosure for RTD-20 x 8

£2,317.16

Accessories for RTD-20 Control Panels

Description

Trade Price

UK.RTD-EXTSEN

Air Curtain External Sensor

£19.95

UK.RTD-INTSEN

Internal Sensor for RTD Device

£12.50

UK.RTD-CABLE

RS485 Cable for wiring RTD Devices 100m Roll

£60.90

UK.RTD-PIR/7.5M

PIR Sensor & 7.5M Cable Assy

£54.00

UK.RTD-PIR/15.0M

7.5m Extension Cable for UK.RTD-PIR/7.5M

£21.45

VRV

RTD-20 Control Panels are sold at listed price. No discounts will apply.

VRV Accessories Centralised Control Solutions

Model

Description

Related Unit

Trade Price

DCS601C51

Intelligent touch controller for up to 64 fan coil units

All units with F1, F2 wiring connection

£1,641.00

KJB411A

Recessed Fixing box for I-Touch controller

DCS601C51

£69.00

DCS302A52

Adaptor PCB for external on/off control of I-Touch controller and I-Touch Manager

DCS601C51

£104.00

DTA103A51

Adaptor PCB for on/off control of external device from I-Touch controller and I-Touch manager

DCS601C51

£305.00

UK.IC Config

I-Touch controller - off site configuration charge (please contact your sales office for info/prices)

DCS601C51

POA

Price List 2015

87


VRV Accessories Centralised Control Solutions

VRV

Model

88

Description

Related Unit

Trade Price

DCM601A51

I-Touch manager central touch screen controller, with integral web server and email function

All units with F1, F2 wiring connection

£2,262.00

DCM601A52

I-Touch manager Expansion Module for up to 64 fan coil units and 4 x kWh Meters

All units with F1, F2 wiring connection

£707.00

DCM002A51

Proportional Power Distribution add-on for I-Touch manager. Provides ability for tenant billing

DCM601A51

POA

DCM008A51

Energy Navigator Software for I-Touch manager. For on screen energy monitoring

DCM601A51

£658.00

DCS302A52

Adaptor PCB for external on/off control of I-Touch controller and I-Touch Manager

DCS601C51

£104.00

DTA103A51

Adaptor PCB for on/off control of external device from I-Touch controller and I-Touch manager

DCS601C51

£305.00

WAGO Interface System

Modular interface system for connection to 3rd Party devices such as lights, pumps, PIR sensors, access card readers, etc. Enables the iTM to control external devices and provide customised interlocks for automation and energy saving logic

DCM601A51

POA

UK.IMAN/CONFIG1

I-Manager Off site configuration per FCU

DCM601A51

POA

UK.IMAN/CONFIG2

I-Manager Off site configuration & graphical layout per FCU. (Allow 4 weeks from order to delivery)

DCM601A51

POA

UK.FS1

On site commissioning for PPD or Energy Navigator Software

DCM601A51

POA

UK.IMAN/SITE TRAIN

On Site customer training for I Touch Manager System

DCM601A51

POA

Residential, Commercial and Industrial


VRV Accessories Fan Coil Accessories (supplied loose) Description

Related Unit

Trade Price

BYCQ140DG

Roundflow cassette decoration panel with self cleaning filter

FXFQ-A

£310.00

BYCQ140DW

Roundflow cassette decoration panel - white with white louvres

FXFQ-A

£160.00

BYFQ60CS

Fully Flat Cassette Decoration Panel - Silver

FXZQ-A

£198.00

BYFQ60B3

Fully Flat Cassette Decoration Panel - Old Style (FXZQ-MA style)

FXZQ-A

£170.00

KDBHQ55B140

Sealing member for air discharge outlet

FXFQ-A

£90.00

BDBHQ44C60

Sealing member for air discharge outlet - Fully Flat cassette

FXZQ-A

£91.00

KDDQ55C140 1&2

Fresh air intake kit for up to 20% fresh air (Not compatible with self-cleaning decoration panel)

FXFQ-A

£233.00

KDDQ50A140

Fresh air intake kit for up to 20% fresh air

FXHQ-A

£158.00

UK.RAC

Return Air filters are available - contact your branch for details

POA

UK.SAF

Return Air filters are available - contact your branch for details

POA

UK.FF8

Filter frame and filter

FXMQ200 to 250

£146.00

KRCS01-4

Remote room mounted temperature sensor

FXFQ-A, FXZQ-A, FXQC-A, FXHQ-A, FXUQ-A, FXSQ-P, FXMQ-P7, FXDQ-A

£42.00

KRCS01-1

Remote room mounted temperature sensor

FXKQ-MA, FXDQ-P9, FXMQ-MA, FXAQ-P, FXLQ-P, FXNQ-P

£46.00

K.RSS

Wireless room mounted temperature sensor and receiver

All

£89.00

RS-SE

Service and Configuration Tool for K.RSS

All

£93.00

VRV

Model

Condensing Unit Accessories (supplied loose) Model

Description

Related Unit

Trade Price

BRP2A81

Adaptor PCB for Heat Cool selection terminals

RYYQ - REYQ-T

£102.00

KRC19-26

Cool/Heat selector switch (BRP2A81 required)

RYYQ - REYQ-T

£32.00

EKPCCAB1

VRV Configurator Software Connection cable. Software available from Daikin Extranet

RYYQ - REYQ-T

£180.00

UK.CGL

Condensing Unit Guard size 100-140 including RXYSQ

£354.00

Strip & Rebuild of Condensing Units

VRV Condensing Units stripped down for delivery to site where lifting into position is difficult with traditional methods. Units are rebuilt on site by Daikin UK Engineers and fully tested

POA

Price List 2015

89


VRV Refrigerant Leak Detection System Refrigerant leak detection systems can be required by the Safety of Building Occupants , BS-EN378. Daikin has a solution that can help meet requirements for leak detection within enclosed spaces.

VRV

Refrigerant Leak Detection Alarm 1) The standard BS-EN378 requires that systems containing R410a refrigerant gas such as VRV, meet the requirements regarding maximum system refrigerant volumes that could leak within Hotel Bedroom or other similar Category Class A spaces. If these limitations are exceeded there must be an alarm system installed within each room where this limit is not met. The alarm system must alert the occupier through both audible and visual indication, and must also alert building staff such as supervisors, night porters etc. There is no specific requirement for the alarm system to be linked to the refrigerant system to pump down or stop the operation, although this can be configured if required by the client. Model

Description

Related Unit

Trade Price

UK.IAM1

Room based refrigerant gas detector with remote room mounted stainless steel facia plate. Provides local audible and visual alarm notification. Terminals for connection to alarm network and optional connection to VRV Fan coil to force system shut down

All

£279.00

UK.IAM2

Network alarm hub for connection of up to 16 room alarms. Hub can be connected in a pyramid formation of 16 groups back to a single unit for connection to a central alarm indicator panel (UK.IAMC)

All

£550.00

UK.IAMC

Alarm buzzer and lamp panel for mounting in a central building supervisor location

All

£388.00

It is recommended that guidance on the selection and installation of these systems is obtained from your local Daikin UK sales office.

90

Residential, Commercial and Industrial


DNSS EcoSave

Y E N E R G P TO GS U SAVIN

The DNSS is a remote monitoring system, which will allow you to continuously optimise the running of your Daikin equipment; control your energy consumption (so reduce your Carbon Footprint), extend the life span of your equipment and reduce operational costs.

25%

E UNIQU N BY ATIO INNOV IKIN DA

Prevent product malfunctions

Extend product lifetime

The DNSS will analyse the data from your equipment every minute of the day and will alert us before the equipment actually breaks down. In this way, failures can be prevented and possible down time reduced to an absolute minimum.

The DNSS is designed to make sure that your equipment is maintained and running as efficiently as possible. This optimisation will extend the lifespan of your equipment.

Remote diagnostics The DNSS continuously checks the cleanliness of the system filters and heat exchanger. Furthermore, the DNSS manages a wide range of data (pressures, temperatures, running hours, etc.) in order to let your equipment run as efficiently and trouble free as possible. This will also prevent your equipment from using too much energy.

VRV

What is the Daikin Network Service System (DNSS)?

Malfunction messages In the unlikely event of a problem occurring, your regional Daikin UK office will contact you directly. Our engineers, who are dedicated to your installation, will inform you regarding the nature of the problem and will help you towards the next step of solving the problem.

Your installation under continuous monitoring > > > > > > >

24/7, 365 days a year remote monitoring Predictive maintenance Improved reliability Improved comfort levels Helps increase efficiency Helps reduce maintenance costs Extends product lifetime

Extra value at low cost > A strategy of preventing breakdowns and limiting unnecessary maintenance visits > Efficiently organising site interventions by diagnosing the nature and the extent of the problem before going to site > Innovative technology that helps to optimise your equipment’s potential > Ensures the most comfortable environment in your premises

Price List 2015

91


VRV


Daikin UK Price List 2015

Ventilation

Scotland Region 0845 641 9330

94

Northern Region 0845 641 9340

Midlands Region 0845 641 9370

VENTILATION

VAM / VKM

Western Region 0845 641 9320

North London 0845 641 9360

South London 0845 641 9355


Ventilation With the advent of new building regulations, greater awareness of increasing energy costs and a responsibility towards environmental issues, modern commercial spaces are insulated better than ever. Double glazing, thicker insulation and draught exclusion of course, help considerably towards reducing heating/cooling demand and burdens on the environment. The down-side however, is that these same commercial spaces have now become, in effect, sealed boxes with little or no replenishment of the air.

Daikin offers a variety of solutions for the provision of fresh air ventilation to offices, hotels, stores and other commercial outlets.

Heat Reclaim Ventilation Correct ventilation is a key component of climate control in buildings, offices and shops. In its basic function, it ensures a flow of incoming fresh air and outgoing stale air. Our HRV (heat reclaim ventilation) solution can do much more. It can recover heat and OPTIMISE THE BALANCE BETWEEN INDOOR AND OUTDOOR TEMPERATURE AND HUMIDITY, thus reducing the load on the system and increasing efficiency.

VENTILATION

VAM / VKM

Total Heat Exchanger VAM150FA VAM250FA VAM350FB VAM500FB VAM650FB VAM800FB VAM1000FB VAM1500FB VAM2000FB VKM50G Dimensions

Height Width Depth

Weight Duct Connections Air Flow Rate Ultra-High High Low External Static Ultra-High Pressure High Low Sound Pressure Ultra-High Level (Heat High Exchange Mode) Low Electrical Details Power Supply

Running Current Max Fuse Size

mm mm mm kg mm m3/hr m3/hr m3/hr Pa Pa Pa dBA dBA dBA V Hz Phase A A

285 776 525 24

301 828 816 33

100Ø 150 150 110 69 39 20 28.5 27.5 21.5

150Ø 250 250 155 64 39 20 29.0 27.0 22.0

364 1004 868 52

150Ø 350 350 230 98 32.0 31.5 23.5

200Ø 500 500 350 98 33.0 31.5 24.5

200Ø 650 650 500 93 34.5 33.0 27.0

250Ø 800 800 670 137 36.0 34.5 31.0

VKM80G

VKM100G

387 1764

1156 64 250Ø 1000 1000 870 157 36.0 35.0 31.0

868 131 350Ø 1500 1500 1200 137 39.5 38.0 34.0

1156 152 350Ø 2000 2000 1400 137 40.0 38.0 35.0

832 96 200Ø 500 500 440 180 150 110 39.0 37.0 35.5

109 250Ø 750 750 640 170 120 80 41.5 39.0 37.0

1214 114 250Ø 950 950 820 150 100 70 41.0 39.0 36.5

3.0 15

5.0 15

5.0 15

3.8 15

3.8 15

3.8 15

230 50 1 0.9 15

0.9 15

0.9 15

1.3 15

Trade Unit Price

£430.00

£514.00

£681.00

£872.00

Optional Accessory Compatibility

VAM150FA

Inlet Heater Battery+ Air Filter

726 1514

VH1B -

VAM250FA

VAM350FB

1.6 15

£1,067.00 £1,257.00 £1,441.00 £2,201.00 £2,871.00 £2,089.00 £2,536.00 £3,016.00 VAM500FB

VH2B -

2.5 15

VAM650FB

VAM800FB

VH3B EKAFV50F*

EKAFV80F*

VAM1000FB

VAM1500FB

VH4B or VH4/AB EKAFV100F*

VAM2000FB

VH5B 2 x EKAFV100F*

=+ Heater battery does NOT require PCB adaptor to connect to VAM * available in Medium M6, Fine F7 and Fine F8. Only one filter is required to cover the whole of one side of the heat exchanger, even if the heat exchanger has two sections.

Optional Inlet Heater Battery Capacity Duct Diamater Trade Unit Price

kW mm

VH1B

VH2B

VH3B

VH4B

VH4/AB

VH5B

1 100 £590.00

1 150 £596.00

1 200 £600.00

1.5 250 £650.00

2.5 250 £644.00

2.5 350 £650.00

Accessories:

Notes:

Accessory Ref

Description

Trade Price

BRC1E52A KRP2A52/UK.FB2 RTD-Net/UK.FB2 RTD-20/UK.FB2 BRP4A50 KRP50-2 BRP4A50A EKAFV50F6 EKAFV50F7 EKAFV50F8 EKAFV80F6 EKAFV80F7 EKAFV80F8 EKAFV100F6 EKAFV100F7 EKAFV100F8 BRYMA65 BRYMA100 BRYMA200

Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock System adaptor PCB for remote on/off, status indication and temperature setting Modbus Interface PCB for Sky Air and VRV Energy control PCB for Sky Air and VRV PCB Adaptor for VAM-A series connection to 3rd party heater PCB Adaptor for VAM-A series connection to humidifier PCB Adaptor for VAM-B Series connection to 3rd party heater or humidifier Air filter for VAM350 / 500FB : Medium M6 Air filter for VAM350 / 500FB : Fine F7 Air filter for VAM350 / 500FB : Fine F8 Air filter for VAM650 / 800FB : Medium M6 Air filter for VAM650 / 800FB : Fine F8 Air filter for VAM650 / 800FB : Fine F7 Air filter for VAM1000 / 2000FB : Medium M6 Air filter for VAM1000 / 2000FB : Fine F7 Air filter for VAM1000 / 2000FB : Fine F8 CO2 Sensor for VAM350 / 500 / 650 CO2 Sensor for VAM800 / 1000 CO2 Sensor for VAM1500 / 2000

£76.00 £202.00 £190.00 POA £94.00 £107.00 £118.00 £51.00 £57.00 £62.00 £57.00 £62.00 £68.00 £87.00 £93.00 £98.00 £376.00 £376.00

94

Residential, Commercial and Industrial

£376.00

i) Please contact your local sales office for required options when combined operation with an air conditioning system is required ii) Optional silencers, high efficiency filters etc are available. Prices and details on request iii) VKM models must be connected as the slave indoor unit of a standard VRV indoor unit and share the same BRC1D52 remote controller and BSVQ unit ( If connected to Heat Recovery) iv) UK.VH-CK VAM EHBX24 conversion kit cable included

New CO2 sensors for VAM-FB range minimise running costs using CO2 sensors to deliver only the ventilation amounts required to maintain your indoor air quality


Daikin UK Price List 2015

Heating Commercial Heating 96 Altherma Flex Product Overview

96

Altherma Flex De-Centralised

97

Altherma Flex Centralised

98

Air-Water Heat Pump

101

Hybrid Heat Pump

111

Heat Emitters

116

Solar Thermal

118

Underfloor Heating

132

HEATING

Domestic Heating 100

As of the 26th September 2015 certain heating products are subject to the Energy Labelling Directive. The corresponding energy labels will be displayed at the following web site www.daikin.co.uk

Dedicated Heating Line: 0845 641 9070 Scotland Region 0845 641 9330

Northern Region 0845 641 9340

Midlands Region 0845 641 9370

Western Region 0845 641 9320

North London 0845 641 9360

South London 0845 641 9355


The Daikin Altherma Flex heat pump series The Daikin Altherma Flex heat pump is ideal for apartment buildings and community heating, providing efficient air-to-water heat pump technology for large residential and commercial buildings.

The product can be configured either as a de-centralised or a centralised system:

HEATING

De-centralised system The hydroboxes can be located in individual dwellings, such as apartments or collective housing, to create a de-centralised system. Each indoor unit can be operated independently, providing each property with individual control of heating, hot water (cooling optional on 50 & 80 class units). The indoor hydrobox units are fully equipped with all the required hydraulic components, so they can be connected easily to the heat distribution system. Individual dwellings can also be equipped with separate domestic hot water tanks, which are designed to stack on top of the indoor units.

Centralised system Alternatively, the indoor units can be located together in one central plant area to create a centralised system suitable for a wide range of commercial and large domestic applications. The centralised indoor units offer modular system scalability and capacity to meet the heating demand of the overall building.

96

Residential, Commercial and Industrial


Altherma Flex Communal Heat Pump De-centralised Daikin Altherma Flex type is the first heating system for apartments and collective housing that fully incorporates the use of renewable energy sources, making large residential buildings more environmentally sustainable by reducing primary energy usage – thus delivering lower running costs and CO2 emissions.

Altherma Flex Outdoor Units EMRQ Outdoor Units Capacity Dimensions Weight Air Flow Rate External Static Pressure Electrical Details

Nominal Heating Height x Width x Depth

High Power Supply Starting current Nominal running Current* Maximum running current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge

Refrigerant Circuit

Sound Pressure Piping Limits

Maximum Length Maximum Vertical Rise Liquid Discharge Gas

Piping Connections

EMRQ8A 22.4

EMRQ10A 28.0

190 78.4

331 190 78.4

amps amps amps amps

74 7.6 17.1 20

74 9.9 22.1 25

kg kg dBA m m mm mm mm

10.3

10.6

58

58

9.52 15.9 19.1 100~260 5 £4,765.00

kW mm kg m3/min Pa

Capacity Index Limit Maximum Number of Connected Indoor Units Trade Condensing Unit Price

EMRQ12A 33.6 1680 x 1300 x 765

EMRQ14A 39.2

EMRQ16A 44.8

235 78.4

240 78.4

4 14.0 32.8 40

4 16.9 33.0 40

11.1

11.1

62

63

9.52 19.1 22.2 125~325 6

210 78.4 3-phase / 400V / 50Hz 75 12.6 22.3 25 R410a 10.8 Refer to Databook 60 100 40 12.7 19.1 28.6 150~390 7

12.7 22.2 28.6 175~455 9

12.7 22.2 28.6 200~520 10

£5,000.00

£5,773.00

£6,806.00

£8,021.00

339

* Nominal running current stated at -3°C ambient air temperature & 75°C leaving water temperature 100% connection ratio

Indoor Units (Hydrobox) Function Heating Capacity Cooling capacity Capacity Index Dimensions Empty Weight Leaving Water Temperature Range Leaving Water Temperature Range Drain valve Water Pump Expansion Vessel Material Colour Electrical Details

kW kW HxWxD heating cooling

mm kg °C °C

Nominal ESP Heating

kPa

Power Supply Starting current Nominal running Current* Maximum running current Fuse Rating

Refrigerant Pipe Sizes Water Side Pipe Sizes Sound Pressure Level Refrigerant

amps amps amps amps mm dBA

Trade Unit Price Hydro Box

EKHVMRD50A EKHVMRD80A EKHVMYD50A EKHVMYD80A Heating & Hot water Heating, hot water & cooling 5.6 9 5.6 9 n/a 5 8 50 80 50 80 705 x 600 x 695 92 120 25~80 n/a 5~20 Yes 83.7 58.8 7 litres heating 7 litres heating, 2 litres cooling Precoated sheet metal Metalic Grey 1-phase / 230V / 50Hz 4 6.5 10.9 6.5 10.9 16.5 20 12.7 Gas, 9.52 Liquid 12.7 Gas, 9.52 Liquid, 15.9 Suction 1" Female 40 42 40 42 R134a Cascade £2,479.00

£2,560.00

£3,045.00

HEATING

Altherma Flex Indoor Units EKHVMRD / EKHVMYD

Hydrobox & cylinder shown in combination

£3,135.00

* Nominal running current stated at -3°C ambient air temperature & 75°C leaving water temperature 100% connection ratio

Hot Water Cylinders EKHTSU

Accessories:

Domestic hot water cylinder Type Water Volume Max Water Temperature Height Width Depth Empty Weight Colour Material Inside Tank Material Outside Casing Piping Connections All Insulation Heat loss / 24hour dt 45°C Heat exchanger surface area

Accessories for hydrobox EKRP1AHT EKRP1HBA RTD-W UK.FB2 EKCC-W EKCLWS EKRUAHTB* EKBUHA6V3** EKBUHA6W1** EKFMAHTB

Trade Unit Price

l °C mm mm mm kg

inch mm m

2

EKHTSU200AC EKHTSU260AC Unvented System (Includes EKUHWHT) 200 260 75 1335 1610 600 695 70 78 Metallic grey Stainless Steel Precoated sheet metal 3/4 " 80 1.2 1.5 1.56 £1,113.00

Notes: i) Refnet joint prices can be found on page 84 ii) Commissioning assistance should be included for each hydrobox iii) DHW cylinder required for hot water function iv) Supplied with 3 way valve and G3 safety kit (EKUHWHTB)

UK.FSHEAT/COMMS***

£1,261.00

Description Optional PCB for demand control Optional PCB for remote alarm monitoring MODBUS interface for HT hydrobox Fixing box for RTD-W Sequence controller Additional thermistor for sequence controller Remote user interface In line back up heater 6kW, 1-phase, 230V In line back up heater 6kW, 3-phase, 400V Kit for standalone installation with floor standing hydrobox Commissioning assistance per hydrobox 1 to 10 hydroboxes Commissioning assistance per hydrobox 11 to 20 hydroboxes Commissioning assistance per hydrobox >20 hydroboxes

Trade price £104.00 £104.00 £205.00 £25.00 £640.00 £75.00 £157.00 £461.00 £461.00 £277.00 £240.00 £216.00 £192.00

Notes: i) * EKRUAHTB: 1 included with each hydrobox ii) ** EKBUHA6V3(W1): Also requires EKRP1AHT iii) *** UK.FSHEAT/COMMS: Commissioning assistance should be included for each hydrobox

Price List 2015

97


Altherma Flex Communal Heat Pump Centralised Daikin Altherma Flex type is the first centralised heating system for schools, public buildings , hotels, gyms & apartments that fully incorporates the use of renewable energy sources, making large buildings more environmentally sustainable by reducing primary energy usage – thus delivering lower running costs and CO2 emissions.

Altherma Flex Outdoor Units EMRQ Outdoor Units Capacity Dimensions Weight Air Flow Rate External Static Pressure Electrical Details

Nominal Heating Height x Width x Depth

High Power Supply Starting current Nominal running Current* Maximum running current Fuse Rating Refrigerant Type Refrigerant Charge Additional Charge

Refrigerant Circuit

Sound Pressure Piping Limits

Maximum Length Maximum Vertical Rise Liquid Discharge Gas

Piping Connections

EMRQ8A 22.4

EMRQ10A 28.0

190 78.4

331 190 78.4

amps amps amps amps

74 7.6 17.1 20

74 9.9 22.1 25

kg kg dBA m m mm mm mm

10.3

10.6

58

58

9.52 15.9 19.1 100~260 5 £4,765.00

kW mm kg m3/min Pa

Capacity Index Limit Maximum Number of Connected Indoor Units Trade Condensing Unit Price

EMRQ12A 33.6 1680 x 1300 x 765

EMRQ14A 39.2

EMRQ16A 44.8

235 78.4

240 78.4

4 14.0 32.8 40

4 16.9 33.0 40

11.1

11.1

62

63

9.52 19.1 22.2 125~325 6

210 78.4 3-phase / 400V / 50Hz 75 12.6 22.3 25 R410a 10.8 Refer to Databook 60 100 40 12.7 19.1 28.6 150~390 7

12.7 22.2 28.6 175~455 9

12.7 22.2 28.6 200~520 10

£5,000.00

£5,773.00

£6,806.00

£8,021.00

339

* Nominal running current stated at -3°C ambient air temperature & 75°C leaving water temperature 100% connection ratio

HEATING

Altherma Flex Indoor Units EKHBRD Indoor Unit (Hydrobox) Function Heating Capacity Cooling capacity Capacity Index Dimensions Empty Weight Leaving Water Temperature Range Drain valve Water Pump Expansion Vessel Material Colour Electrical Details

kW kW HxWxD

EKHBRD 011ACV1

EKHBRD 014ACV1

11

14

100

125

mm kg °C

heating

Refrigerant Pipe Sizes Water Side Pipe Sizes Sound Pressure Level Refrigerant

amps amps amps amps mm dBA

Trade Unit Price Hydro Box

EKHBRD 011ACY1

EKHBRD 014ACY1

EKHBRD 016ACY1

14

16

125

140

Heating & Hot water 16 11 n/a 140 100 705 x 600 x 695

145

148 25~80 Yes

92

Power Supply Starting current Nominal running Current* Maximum running current Fuse Rating

EKHBRD 016ACV1

11.6 22.5

88

85

92 12 litres Precoated sheet metal Metalic Grey

230V 1ph 4 15.1 23.8 25

18.1 23.8

88

400V 3ph 4 5.6 12.5 16

4.3 12.5

15.9 Gas, 9.52 Liquid 1” Female 46 43 R134a Cascade

43

45

£2,985.00

£3,038.00

£3,130.00

£3,045.00

85

6.7 12.5

45

46

£3,099.00

£3,192.00

* Nominal running current stated at -3°C ambient air temperature & 75°C leaving water temperature 100% connection ratio

Pre Selected Combinations Heating capacity (1) A7W35

kW

28.0

31.4

42.0

Heating capacity (2) A-3W65

kW

23.9

26.7

34.3

Outdoor unit Hydroboxes Demand PCBs Refnets Trade Price

1 x EMRQ8 2 x EKHBRD014ACV1 2 x EKRP1AHT 1 x KHRQ22M29T9 £11,085.00

£4,765.00 £6,076.00 £208.00 £36.00

1 x EMRQ10 2 x EKHBRD016ACV1 2 x EKRP1AHT 1 x KHRQ22M29T9

£5,000.00 £6,260.00 £208.00 £36.00

£11,504.00

(1) Heating ambient air temperature 7°C and leaving water temperature 35°C (2) Heating ambient air temperature -3°C and leaving water temperature 65°C, capacity stated net of 1 defrost cycle per hour

Notes: i) Refnet joints can be found on page 84 ii) Commissioning assistance should be included per hydrobox iii) DHW cylinder required for hot water function iv) See page 97 for accessories

98

Residential, Commercial and Industrial

1 x EMRQ12 3 x EKHBRD014ACV1 3 x EKRP1AHT 1 x KHRQ22M64H £15,338.00

47.0 38.7 £5,773.00 £9,114.00 £312.00 £139.00

1 x EMRQ14 3 x EKHBRD016ACV1 3 x EKRP1AHT 1 x KHRQ22M64H £16,647.00

£6,806.00 £9,390.00 £312.00 £139.00


HEATING


*

Daikin heating systems

HEATING

As a leading heating supplier, Daikin’s product portfolio comprises a wide range of highly energy efficient renewable energy systems, providing the right heating solution for any application and requirement.

Daikin Altherma air-water heat pump is a renewable energy heating and hot water solution, ideally suited for the UK housing market. Using renewable air as a heat source and heat pump technology with Daikin’s advanced inverter compressor technology, Daikin Altherma delivers high seasonal efficiencies, low running costs and reduced carbon emissions compared to traditional systems. Launched in 2006 with over 200,000 installed across Europe, Daikin Altherma is the leading air-water heat pump. Daikin Altherma offers the most comprehensive and flexible range of air-water heat pumps in the market today, suitable for houses, flats and both new build and refurbishment projects. The range is available in Low Temperature (Split and Monobloc) and High Temperature. Daikin Altherma High Temperature is an industry first system that can deliver water temperatures of up to 80°C, providing an ideal solution for boiler replacement in harder to treat properties.

The majority of Daikin Altherma air water heat pumps* are certified by the Microgeneration Certification Scheme (MCS) and the Daikin solar thermal collectors have Solar Keymark approval and therefore are eligible for the domestic RHI. Please check the MCS website for the latest list of accredited Daikin Altherma air-water heat pumps. Daikin is at the forefront of the drive for energy efficient heat pump technology, recognising that heat pumps and the use of renewable energy from the surrounding air is the answer to meet the future challenges of energy efficiency and carbon reduction targets. Daikin renewable energy solutions provide a real alternative to current and future problems associated with conventional heating systems such as increasing primary energy costs and unacceptably high environmental impact.

Daikin solar thermal systems can be combined with Daikin Altherma to provide a fully integrated renewable energy solution. Daikin Altherma and Daikin solar thermal systems are recognised renewable energy solutions that can reduce hot water energy costs by up to 60% compared to traditional fossil fuel systems.

* Except Daikin Altherma Flex Type

100

Residential, Commercial and Industrial

MCS HP0006

011-7S1016 F

MCS scheme

Solar Keymark


HEATING

Air-Water heat pump

Daikin Altherma Air-Water heat pump is available in the following models: Daikin Altherma Low Temperature Split 4-16kW

Daikin Altherma Low Temperature Monobloc 6-16kW

> L atest inverter technology, high seasonal efficiencies and low running costs

> All key hydraulics built-in, e.g. expansion vessel and circulation pump

> Guaranteed operation down to -25째C

> Sealed refrigerant circuit with no F-gas needed for installation

> New easy to use back lit controller > New indoor unit with front access for easy maintenance

Daikin Altherma High Temperature 11-16kW

> F lexible siting with indoor unit and small outdoor unit which can be sited up to 30m away

> Providing flow temperatures up to 80째C

*

Daikin Altherma Flex Type 22.4-44.8kW > For commercial heating applications

* Except Daikin Altherma Flex Type

Price List 2015

101


ERLQ-CV3

Low Temperature Split heat pump (outdoor) Outdoor Units

Single Phase ERLQ004CV3

Dimensions Weight Nominal capacity Nominal input COP EER Operation range

Sound pressure / power level Refrigerant charge Piping connections

Height x Width x Depth Heating (a/b) Cooling Heating (a/b) Cooling Heating (a/b) Cooling Heating Cooling Hot water Heating Cooling R-410A Liquid Gas

Max piping length OU to IU Power supply Recommended fuses

mm kg kW kW kW kW

°C °C °C dBA dBA kg inches inches m

ERLQ006CV3

ERLQ008CV3

ERLQ011CV3

735 x 832 x 307 54 4.4 / 4.2 4.17 0.87 / 1.85 1.8 5.04 / 2.27 2.32

56 6.0 / 5.12 4.84 1.27 / 2.31 2.07 4.74 / 2.22 2.34 -25~25 10~43 -25~35 48 / 61 49 / 63 1.6 1/4 5/8 30

48 / 61 48 / 63 1.45

ERLQ014CV3

ERLQ016CV3

1345 x 900 x 320 56 7.4 / 6.13 5.36 1.66 / 2.89 2.34 4.45 / 2.12 2.29

11.2 / 9.6 11.72 2.43 / 4.57 4.31 4.60 / 2.1 2.72

49 / 62 50 / 63 1.6

51 / 64 50 / 64

113 14.5 / 10.8 12.55 3.37 / 5.19 5.08 4.30 / 2.08 2.47 -25~35 10~46 -20~35 51 / 64 52 / 66 3.4 3/8 5/8 50

16.0 / 10.9 13.12 3.76 / 5.22 5.73 4.25 / 2.09 2.29

52 / 66 54 / 69

1-phase / 230V / 50Hz A

Trade Unit Price

20 £1,084.00

£1,106.00

40 £1,481.00

£2,297.00

£,2647.00

£2,894.00

HEATING

Nominal capacity and nominal input tested according to EN 14511 at the following conditions: Heating a: Ambient air temperature 7°C and leaving water temperature 35°C (A7 W35) Heating b: Ambient air temperature -7°C and leaving water temperature 45°C (A-7 W45) Cooling: Ambient air temperature 35°C and leaving water temperature 7°C (A35 W7) Sound pressure level measured at 1m from the unit

ERLQ-CW1

Low Temperature Split heat pump (outdoor) Outdoor Units

3 Phase ERLQ011CW1

Dimensions Weight Nominal capacity Nominal input COP EER Operation range

Sound pressure / power level Refrigerant charge Piping connections Max piping length OU to IU Power supply Recommended fuses

Height x Width x Depth Heating (a/b) Cooling Heating (a/b) Cooling Heating (a/b) Cooling Heating Cooling Hot water Heating Cooling R-410A Liquid Gas

mm kg kW kW kW kW

°C °C °C dBA dBA kg inches inches m

11.2 / 9.6 11.72 2.43 / 4.57 4.31 4.60 / 2.1 2.72

51 / 64 50 / 64

A

Trade Unit Price

ERLQ014CW1

ERLQ016CW1

1345 x 900 x 320 113 14.5 / 10.8 12.55 3.37 / 5.19 5.08 4.30 / 2.08 2.47 -25~35 10~46 -20~35 51 / 64 52 / 66 3.4 3/8 5/8 50 3-phase / 400V / 50Hz 40

£2,521.00

16.0 / 10.9 13.12 3.76 / 5.22 5.73 4.25 / 2.09 2.29

52 / 66 54 / 69

£2,906.00

£3,177.00

Nominal capacity and nominal input tested according to EN 14511 at the following conditions: Heating a: Ambient air temperature 7°C and leaving water temperature 35°C (A7 W35) Heating b: Ambient air temperature -7°C and leaving water temperature 45°C (A-7 W45) Cooling: Ambient air temperature 35°C and leaving water temperature 7°C (A35 W7) Sound pressure level measured at 1m from the unit

Features:

Notes:

> This split system consists of an outdoor unit and an indoor hydrobox that can be connected to all standard low temperature radiators and underfloor heating systems > The ERLQ-C models have extra features to withstand severe winter conditions

i) Some units are available on special request with Blygold treatment to offer additional protection in coastal environments. Please contact your local sales office for further information

102

Residential, Commercial and Industrial


EHBH / EHBX

Low Temperature Split hydrobox (wall hung) Indoor Unit (wall hung)

Single Phase

Single / 3 Phase*

EHBH04C3V

EHBH08C3V

EHBH16C3V

EHBH08C9W

Function

Heating Only

Heating Only

Heating Only

Heating Only

Heating Only

To use with

ERLQ004CV3

ERLQ006-008CV3

ERLQ011-016CV3

ERLQ006-008CV3

ERLQ011-016CV3/W1

Dimensions

Height x Width x Depth

mm

Leaving water temperature range

Heating

°C

Cooling

°C

Pump

No. of speeds

890 x 480 x 344 / 381 (including cover of user interface) 15~55 Inverter controlled

litres

10

Water connections

Diameter

inches

Back-up heater fuse rating

3kW 1ph 230V

A

6kW 1ph 230V

A

-

32**

6kW 3ph 400V

A

-

10**

9kW 3ph 400V

A

-

16**

Trade Unit Price

1 ¼ (female) 16

£1,236.00

Indoor Unit (wall hung)

£1,261.00

£1,715.00

£1,272.00

Single Phase

Function To use with Dimensions

Height x Width x Depth

mm

Leaving water temperature range

Heating

°C

Cooling

°C

Pump

No. of speeds

Expansion vessel volume

Single / 3 Phase*

EHBX04C3V

EHBX08C3V

EHBX16C3V

EHBX08C9W

Reversible

Reversible

Reversible

Reversible

Reversible

ERLQ004CV3

ERLQ006-008CV3

ERLQ011-016CV3

ERLQ006-008CV3

ERLQ011-016CV3/W1

15~55 5~22 Inverter controlled

litres

10

Diameter

Back-up heater fuse rating

3kW 1ph 230V

A

6kW 1ph 230V

A

-

32**

6kW 3ph 400V

A

-

10**

9kW 3ph 400V

A

-

16**

inches

1 ¼ (female) 16

£1,447.00

£1,476.00

£1,982.00

Accessories:

£1,493.00

£2,074.00

Notes:

Accessory Ref

Description

Trade Price

EKPCCAB2 EKRUCL1 EKRSC1 KRCS01-1 EKRP1HBA

PC cable – to upload field settings from PC to unit or spare controller Optional second user interface or remote room thermostat Optional remote outdoor temperature sensor Optional remote indoor temperature sensor Optional PCB kit for remote alarm monitoring, run and fault indication, solar interlock for heat pump and bivalent operation U-beams to mount the outdoor units for ERLQ 004-008 Drainpan and U-beams for outdoor units ERLQ 004-008 Drainpan kit for indoor units EHBX 004-016 Heater mat for drainpan (EKDP008C) Wall mounting bracket for outdoor units ERLQ 004-008 Wall mounting bracket for outdoor units ERLQ 011-016 Condensate drip tray for use with UK.CWB90-2 Condensate drip tray for use with UK.CWB140-2 Outdoor unit guard for ERLQ 004-008 Outdoor unit guard for ERLQ 011-016

£180.00 £94.00 £61.00 £46.00 £104.00

EKFT008CA EKDP008C EKHBDPC2 EKDPH008C UK.CWB90-2 UK.CWB140-2 UK.DT1 UK.DT2 UK.CGM UK.CGL

EHBX16C9W

890 x 480 x 344 / 381 (including cover of user interface)

Water connections

Trade Unit Price

£1,831.00

HEATING

Expansion vessel volume

EHBH16C9W

i) * Back-up heater can be re-wired as 3kW/1ph, 6kW 1ph, 6kW/3ph or 9kW/3ph ii) ** 9W models only iii) Only one optional remote sensor can be installed. Sensor connects to indoor hydrobox

£83.00 £116.00 £112.00 £176.00 £36.00 £46.00 £54.00 £59.00 £296.00 £354.00

Features: > Available in heating only or heating/cooling versions > A choice of back-up heaters 3, 6 or 9kW > Heating / cooling hydroboxes are delivered with drain pan and insulation kit as standard

Price List 2015

103


EBHQ

Low Temperature Monobloc heat pump (6-8kW) Outdoor Unit

EBHQ006BBV3

Dimensions

EBHQ008BBV3

Height x Width x Depth

mm

Heating (a/b)

kW

6.00 / 3.77

Cooling

kW

5.12

6.08

Nominal input

Heating (a/b)

kW

1.41 / 1.88

2.21 / 2.56

Cooling

kW

COP

Heating (a/b)

Weight

805 x 1190 x 360

kg

Nominal capacity

EER

Cooling

Operation range

Heating

95 8.85 / 5.26

2.16

2.75

4.26 / 2.00

4.00 / 2.05

2.37 °C

2.21 -15 ~ 25

Cooling

°C

10 ~ 43

Hot water

°C

-15 ~ 35

Sound pressure / power level

Heating

dBA

48 / 61

49 / 62

Cooling

dBA

48 / 63

50 / 63

Refrigerant charge (factory)

R-410A

kg

1.7

Power supply

1-phase / 230V / 50Hz

Recommended fuses Pump

A

20

No. of speeds

Expansion vessel volume Water connections

3 litres

Diameter

Max piping length OU to cylinder

6

inches

1 (male)

m

10

Interconnecting cable

EKCOMCAB1 (12m) – delivered separately

Trade Unit Price

£2,000.00

£2,288.00

HEATING

Nominal capacity and nominal input tested according to EN 14511 at the following conditions: Heating a: Ambient air temperature 7°C and leaving water temperature 35°C (A7 W35) Heating b: Ambient air temperature -7°C and leaving water temperature 45°C (A-7 W45) Cooling: Ambient air temperature 35°C and leaving water temperature 7°C (A35 W7) Sound pressure level measured at 1m from the unit

Accessories:

Notes:

Accessory Ref

Description

Trade Price

EKCOMCAB1 EKMBUHB6V3 EKCBH008BCV3 EKCBX008BCV3 EKBPHT08B EKRP1HBA

Data cable (12m) Note: Must be ordered with every EBHQ 006-008 Back up heater kit (3/6kW) Control box – heating only Control box – heating / cooling Bottom plate heater for outdoor units sizes 006-008 (see note) Optional PCB kit for remote alarm monitoring, run and fault indication, solar interlock for heat pump and bivalent operation Optional wired room thermostatic controller Optional wireless room thermostatic controller Floor temperature sensor for use with wireless room thermostat EKRTR

£60.00 £436.00 £186.00 £298.00 £77.00 £104.00

EKRTWA EKRTR EKRTETS

i) It is strongly recommended to install the bottom plate heater in units that will be installed in a region that will experience prolonged periods below 0°C with very high humidity

£99.00 £194.00 £14.00

Features: > The small Daikin Altherma Monobloc is ideal for smaller properties > In this system, water pipes, rather than refrigerant lines, run from the outdoor unit to indoors which means that no special refrigerant handling is necessary > The back-up heater is installed indoors

For Low Temperature Monobloc (6-8kW)

Back up heater and control box Function

EKCBH008BCV3

EKCBX008BCV3

Back up heater

Control box – heating only

Control box – reversible

EBHQ006~008BBV3 Max depth

mm

170

Max width

mm

380

412

Max height

mm

575

390

Power supply Water connections

A Diameter

inches

Trade Unit Price

104

100 (excluding user interface) / 120 (including user interface)

1-phase / 230V / 50Hz

Recommended fuses

Residential, Commercial and Industrial

Control box

EKMBUHB6V3 To use with Dimensions

Back up heater

32 (6kW BUH)

-

-

£436.00

£186.00

£298.00


EDHQ

Low Temperature Monobloc heat pump (11-16kW) Outdoor Unit

Single Phase

Function Dimensions

Height x Width x Depth

mm

Heating (a/b)

kW

Cooling

kW

Heating (a/b)

kW

Cooling

kW

Weight

EDHQ014BB6V3

EDHQ016BB6V3

EDHQ011BB6W1

EDHQ014BB6W1

EDHQ016BB6W1

Heating Only

Heating Only

Heating Only

Heating Only

Heating Only

Heating Only

1418 x 1435 x 382

kg

Nominal capacity Nominal input COP

Heating (a/b)

EER

Cooling

Operation range

14 / 7.72

180 16 / 8.7

11.2 / 6.19

14 / 7.72

16 / 8.7

3.88 / 4.44

2.6 / 3.11

3.31 / 3.84

3.81 / 4.39

4.12 / 1.96

4.3 / 1.99

4.23 / 2.01

4.2 / 1.98

2.56 / 3.21

3.29 / 3.76 4.25 / 2.05 -

-15~35

Heating

°C

-15~35

Cooling

°C

-

-

Hot water

°C

-15~35

-15~35

Heating

dBA

Cooling

dBA

Refrigerant charge (factory)

R-410A

Back up heater (factory fitted)

51 / 64

51 / 65

52 / 66

49 / 64

51 / 65

-

-

kg

2.95

2.95

kW

6

6

1-phase / 230V / 50Hz

3-phase / 400V / 50Hz

Power supply

Pump

1418 x 1435 x 382

180 11.2 / 6.19

4.38 / 1.93

Sound pressure / power level

Recommended fuses

3 Phase

EDHQ011BB6V3

Outdoor unit

A

32

20

6kW BUH

A

32

20

No. of speeds

Expansion vessel volume

2

2

10

10

1 ¼ (female)

1 ¼ (female)

10

10

litres

Water connections (diameter)

inches

Max piping length OU to cylinder

m

Trade Unit Price

£3,753.00

£4,064.00

£4,282.00

£3,951.00

£4,291.00

53 / 66

£4,532.00

Accessories:

Notes:

Accessory Ref

Description

Trade Price

EKBPHTH16A EKRP1HBA

Bottom plate heater for outdoor units sizes 011-016 (see note) Optional PCB kit for remote alarm monitoring, run and fault indication, solar interlock for heat pump and bivalent operation Optional wired room thermostatic controller Optional wireless room thermostatic controller Floor temperature sensor for use with wireless room thermostat EKRTR

£132.00 £104.00

EKRTWA EKRTR EKRTETS

HEATING

Nominal capacity and nominal input tested according to EN 14511 at the following conditions: Heating a: Ambient air temperature 7°C and leaving water temperature 35°C (A7 W35) Heating b: Ambient air temperature -7°C and leaving water temperature 45°C (A-7 W45) Cooling: Ambient air temperature 35°C and leaving water temperature 7°C (A35 W7) Sound pressure level measured at 1m from the unit

£99.00 £194.00 £14.00

i) It is strongly recommended to install the bottom plate heater in units that will be installed in a region that will experience prolonged periods below 0°C with very high humidity

Features: > The Daikin Altherma Monobloc contains all components and the back-up heater in the outdoor unit > In this system, water pipes, rather than refrigerant lines, run from the outdoor unit to indoors which means that no special refrigerant handling is necessary for installation

Price List 2015

105


EBHQ

Low Temperature Monobloc heat pump (11-16kW) Outdoor Unit

Single Phase

Function Dimensions

EBHQ014BB6V3

EBHQ016BB6V3

EBHQ011BB6W1

EBHQ014BB6W1

EBHQ016BB6W1

Reversible

Reversible

Reversible

Reversible

Reversible

Reversible

Height x Width x Depth

mm

Heating (a/b)

kW

11.2 / 6.19

14 / 7.72

16 / 8.7

11.2 / 6.19

14 / 7.72

Cooling

kW

10

12.5

13.1

10

12.5

13.1

Nominal input

Heating (a/b)

kW

2.56 / 3.21

3.29 / 3.76

3.88 / 4.44

2.6 / 3.11

3.3 / 3.84

3.81 / 4.39

Cooling

kW

COP

Heating (a/b)

Weight

1418 x 1435 x 382

kg

Nominal capacity

EER

Cooling

Operation range

Heating

1418 x 1435 x 382

180

180 16 / 8.7

3.69

5.39

5.93

3.69

5.06

5.75

4.38 / 1.93

4.25 / 2.05

4.12 / 1.96

4.3 / 1.99

4.23 / 2.01

4.2 / 1.98

2.32

2.21

2.71

2.47

2.28

2.71 °C

-15~35

-15~35

Cooling

°C

10~46

10~46

Hot water

°C

-15~35

-15~35

Sound pressure / power level

Heating

dBA

51 / 64

51 / 65

52 / 66

49 / 64

51 / 65

53 / 66

Cooling

dBA

50 / 65

52 / 66

54 / 69

50 / 65

52 / 66

54 / 69

Refrigerant charge (factory)

R-410A

Back up heater (factory fitted)

kg

2.95

kW

6

6

1-phase / 230V / 50Hz

3-phase / 400V / 50Hz

Power supply Recommended fuses Pump

2.95

Outdoor unit

A

32

20

6kW BUH

A

32

20

No. of speeds

Expansion vessel volume

2

2

10

10

1 ¼ (female)

1 ¼ (female)

10

10

litres

Water connections (diameter)

inches

Max piping length OU to cylinder

m

Trade Unit Price

HEATING

3 Phase

EBHQ011BB6V3

£3,912.00

£4,219.00

£4,438.00

£4,106.00

£4,447.00

£4,688.00

Nominal capacity and nominal input tested according to EN 14511 at the following conditions: Heating a: Ambient air temperature 7°C and leaving water temperature 35°C (A7 W35) Heating b: Ambient air temperature -7°C and leaving water temperature 45°C (A-7 W45) Cooling: Ambient air temperature 35°C and leaving water temperature 7°C (A35 W7) Sound pressure level measured at 1m from the unit

EKHWSU

Hot water cylinder for Low Temperature Split and Monobloc Domestic hot water cylinder Suitable for Water volume Max water temperature Booster heater capacity Power supply Recommended fuses Height Diameter Empty weight Material inside cylinder Piping connections (diameter)

UK.EKHWSU150B3V3 litres °C kW

150

A mm mm kg Water inlet H/E Water outlet H/E Cold water in Hot water out

1015 38

inch inch inch inch

Trade Unit Price

UK.EKHWSU200B3V3

£1,064.00

£1,081.00

Accessories:

300

1715 60

£1,188.00

Notes:

Accessory Ref

Description

Trade Price

EKSOLHW + EKUHW2WB

Solar connection kit for EKHWSU cylinder for connecting to solar panels (see note)

£533.00

Features: > This stainless steel unvented cylinder is the ideal partner for Daikin Altherma Low Temperature Split and Monobloc heat pumps > Fitted with 3kW immersion heater as standard > Supplied with 3-way valve and G3 safety kit (EKUHWBB) > For vented hot water cylinders, please contact your local sales office

106

UK.EKHWSU300B3V3

Unvented systems (EKUHWBB kit also required) 200 85 3 1-phase / 230V / 50Hz 16 1265 580 46 Stainless steel 3/4 (female) 3/4 (female) 3/4 (female) 3/4 (female)

Residential, Commercial and Industrial

i) A specially designed kit transfers solar heat into the Daikin Altherma hot water cylinder via an external heat exchanger, which allows the entire content of the cylinder to be heated efficiently with solar heat. Price shown includes EKUHW2WB 2-way valve. Delivered with EKRP1HBA PCB adaptor


HEATING


ERSQ

High Temperature Split heat pump (outdoor) Outdoor Unit

Single Phase ERSQ011AV1

Dimensions

ERSQ014AV1

3 Phase ERSQ016AV1

ERSQ011AY1

mm

Nominal capacity

Heating (a/b)

kW

11 / 11

14 / 14

16 / 16

11 / 11

14 / 14

16 / 16

Nominal input

Heating (a/b)

kW

3.03 / 3.57

4.07 / 4.66

4.83 / 5.57

3.03 / 3.57

4.07 / 4.66

4.83 / 5.57

COP

Heating (a/b)

3.63 / 3.08

3.44 / 3.00

3.31 / 2.88

3.63 / 3.08

3.44 / 3.00

3.31 / 2.88

Operation range

Heating Hot water

°C

Sound pressure / power level Refrigerant charge

Heating R-410A

dBA kg

kg

Piping connections

1345 x 900 x 320

120

°C

120

-20 ~ + 24

-20 ~ + 24

-20 ~ + 35 52 / 68

53 / 69 4.5

-20 ~ + 35 55 / 71

52 / 68

Liquid

inches

3/8

3/8

inches

5/8

5/8

Max piping length OU to IU Recommended fuses

m

50

50

1-phase / 230V / 50Hz

3-phase / 400V / 50Hz

25

16

A

Trade Unit Price

£2,472.00

£2,789.00

£3,013.00

£2,699.00

Nominal capacity and nominal input tested at the following conditions: a. A7 W45 according to EN14511 b. A7 W65 according to Eurovent rating standard 6/C/003-2006

Accessories: Accessory Ref

Description

Trade Price

EKBPHTH16A EKBUHA6V3 EKBUHA6W1 EKRP1AHT EKRUAHTB EKRP1HBA EKRTWA EKRTR EKRTETS UK.CWB140-2 UK.DT2 UK.CGL

Bottom plate heater for outdoor unit sizes 011-016 In line back up electric heater 6kW, 1-phase, 230V (also requires EKRP1AHT) – for space heating only In line back up electric heater 6kW, 3-phase, 400V (also requires EKRP1AHT) – for space heating only Optional PCB for demand control (required for EKRTW, EKRTR, EKRTETS, EKBUH*) Remote user interface Optional PCB kit for remote alarm monitoring, run and fault indication and solar interlock for heat pump Optional wired room thermostatic controller (also requires EKRP1AHT) Optional wireless room thermostatic controller (also requires EKRP1AHT) Floor temperature sensor for use with EKRTR (also requires EKRP1AHT) Wall mounting bracket for outdoor unit ERSQ 011-016 Condensate drip tray for use with UK.CWB140-2 Outdoor unit guard for ERSQ 011-016

£132.00 £461.00 £461.00 £104.00 £157.00 £104.00 £99.00 £194.00 £14.00 £46.00 £59.00 £354.00

Features: > The outdoor unit extracts heat from the ambient air and transfers it to the indoor unit via refrigerant piping > Heating only versions > Order with matching indoor unit

108

53 / 69 4.5

Gas Power supply

HEATING

ERSQ016AY1

Height x Width x Depth

Weight

1345 x 900 x 320

ERSQ014AY1

Residential, Commercial and Industrial

£2,831.00

55 / 71

£3,345.00


EKHB

High Temperature Split hydrobox (floor standing) Indoor Unit (floor standing)

Single Phase

3 Phase

EKHBRD011ACV1 EKHBRD014ACV1 EKHBRD016ACV1 EKHBRD011ACY1 To use with Dimensions Height x Width x Depth Weight Leaving water temperature range Refrigerant charge (factory) R134a Power supply Recommended fuses Pump No. of speeds Expansion vessel volume Water connections (diameter)

ERSQ011AV1

ERSQ014AV1 ERSQ016AV1 705 x 600 x 695 144.25 25~80 without electrical heater 3.2 1-phase / 230V / 50Hz 25 Inverter controlled 12 1 (female)

mm kg °C kg A litres inch

Trade Unit Price

£2,985.00

£3,038.00

EKHBRD014ACY1

EKHBRD016ACY1

ERSQ011AY1

ERSQ014AY1 ERSQ016AY1 705 x 600 x 695 147.25 25~80 without electrical heater 3.2 3-phase / 400V / 50Hz 25 Inverter controlled 12 1 (female)

£3,130.00

£3,045.00

£3,099.00

£3,192.00

Accessories: Accessory Ref

Description

Trade Price

EKBPHTH16A EKBUHA6V3 EKBUHA6W1 EKRP1AHT EKRUAHTB EKRP1HBA EKRTWA EKRTR EKRTETS UK.CWB140-2 UK.DT2 UK.CGL

Bottom plate heater for outdoor unit sizes 011-016 In line back up electric heater 6kW, 1-phase, 230V (also requires EKRP1AHT) – for space heating only In line back up electric heater 6kW, 3-phase, 400V (also requires EKRP1AHT) – for space heating only Optional PCB for demand control (required for EKRTW, EKRTR, EKRTETS, EKBUH*) Remote user interface Optional PCB kit for remote alarm monitoring, run and fault indication and solar interlock for heat pump Optional wired room thermostatic controller (also requires EKRP1AHT) Optional wireless room thermostatic controller (also requires EKRP1AHT) Floor temperature sensor for use with EKRTR (also requires EKRP1AHT) Wall mounting bracket for outdoor unit ERSQ 011-016 Condensate drip tray for use with UK.CWB140-2 Outdoor unit guard for ERSQ 011-016

£132.00 £461.00 £461.00 £104.00 £157.00 £104.00 £99.00 £194.00 £14.00 £46.00 £59.00 £354.00

Features: HEATING

> The indoor unit receives the heat from the outdoor unit and further increases the temperature up to 80°C, which is ideal for use with existing radiators > It is designed to only be used with the integrated hot water cylinder EKHTSU > For RHI, check maximum design flow temperature carefully

EKHTSU

Hot water cylinder for High Temperature Split Domestic hot water cylinder Suitable for Water volume Max water temperature Dimensions (cylinder only) Dimensions (cylinder integrated on hydrobox) Empty weight Material inside cylinder Piping connections (diameter)

UK.EKHTSU200AC

UK.EKHTSU260AC Unvented systems (including EKUHWHTB)

Height x Width x Depth Height x Width x Depth

Litres °C mm mm kg

Water inlet H/E Water outlet H/E Cold water in Hot water out

mm mm inch inch

Trade Unit Price

200

260 75

1335 x 600 x 695 2010 x 600 x 695

1610 x 600 x 695 2285 x 600 x 695

70

78 Stainless steel 25 (female quick coupling, supplied, integrated solution) 25 (female quick coupling, supplied, integrated solution) 3/4 (female) 3/4 (female)

£1,113.00

£1,261.00

Accessories: Accessory Ref

Description

Trade Price

EKFMAHTB

Kit for standalone installation with floor standing hydrobox

£277.00

Features: > This integrated cylinder is designed for use with Daikin Altherma HT only > The cylinder features fast heat-up and recovery times, and low heat losses > The indoor unit and hot water cylinder are designed to be stacked to save space, or can alternatively be installed next to each other if limited height is available for installation > Supplied with 3-way valve and G3 safety kit (EKUHWHTB)

Price List 2015

109


Air-Water heat pump combination table Daikin have a full range of air-water heat pumps to suit many installation requirements and applications. Use the table below to help select the right combination of equipment.

LT Split 4-16kW

Outdoor

Indoor

DHW cylinder

or

Thermal store

or

ERLQ004-008 (page 102)

EHBH/X04-16 ERLQ011-016

(page 103)

LT Monobloc 6-8kW

EKHWSU150-300B

EKHWP300-500B

(page 106)

Control box EKCBH/X (page 104)

or

EBHQ006-008 + EKCOMCAB1 (page 104)

Back-up heater (optional) EKMBUH (page 104)

EKHWSU150-300B

EKHWP300-500B

LT Monobloc 11-16kW

(page 106)

or

EDHQ/EBHQ011-016

EKHWSU150-300B

(page 105)

110

EKHWP300-500B

(page 106)

HT Split 11-16kW

HEATING

(page 102)

or

ERSQ011-016

EKHBRD011-016

EKHTSU200-260AC

(page 108)

(page 109)

(page 109)

Residential, Commercial and Industrial

EKHWP300-500B


Hybrid heat pump The Daikin Altherma Hybrid Heat Pump is unique technology. It combines a high efficiency gas combi boiler with a renewable energy air-water heat pump, all in one efficient, compact heating system.

Daikin Altherma Hybrid heat pump The smart hybrid logic automatically selects the most energy efficient and cost-effective operation based on the user’s energy tariff, at any given temperature to make it the most efficient solution on the market.

> S ingle easy to use backlit control using energy tariffs for automatic control

> S uitable for heating systems requiring flow temperatures up to 80°C

> Heat pump capacity: 5 and 8kW

> E ligible for RHI when fitted with required heat and electric meters > Single compact indoor unit to minimise space

> A ll key components built in: A-label pump, expansion vessel, pressure relief

> B oiler output CH 27kW (80/60) and DHW 33kW (13 l/min at dT 35K) > Boiler SEDBUK (2009) rated 89.1% (natural gas) and 90.1% (LPG) > Dedicated training courses available

> No DHW tank needed – hot water delivered by combi boiler

HEATING

> S uitable for LPG applications for even higher running cost savings

Price List 2015

111


EHYH/K / EVLQ

Daikin Altherma hybrid heat pump system Indoor Unit and boiler wall hung (1 combined unit) Indoor Unit (heat pump) Function To use with Dimensions Weight Leaving water temperature range Pump Expansion vessel volume Indoor Unit (boiler)

Height x Width x Depth Heating

mm kg °C

EHYHBH05AV32

EHYHBH08AV32

Heating Only EVLQ05CV3

Heating Only EVLQ08CV3 1075 x 450 x 164

30

No. of speeds

Inverter controlled 10 EHYKOMB33AA2

litres

Function To use with Dimensions Max dimensions (boiler and heat pump) Weight Capacity (heating) Capacity (hot water) Leaving water temperature range

HEATING

DHW flow rate dT 35K Heating connections DHW connections Gas connection IP rating Device type Supply pressure

Height x Width x Depth Height x Width x Depth

mm mm

Minimum Maximum Minimum Maximum Heating Hot water Hot water Diameter Diameter Diameter

kg kW kW kW kW °C °C l/min mm mm mm

Natural gas (G20) LPG (G31)

mbar mbar

Nox class Flue gas connection Maximum flue length, 60/100 Maximum flue length, 80/125 SEDBUK rating (2009)

Max piping length OU to IU Power supply Recommended fuses

1075 x 450 x 405 36 7.6 27 7.6 32.7 15 ~ 80 40 ~ 65 13.1 22 15 15 IP44 C13, C33, C53 20 30-37 5 60/100 10 29 89.1 (NG) / 90.1 (LPG) EVLQ05CV3

Height x Width x Depth Heating Heating Heating Heating Heating R-410A Liquid Gas

mm kg kW kW °C dBA kg inches inches m A

Nominal capacity and nominal input tested according to EN 14511 at the following conditions: Heating: Ambient air temperature 7°C and leaving water temperature 35°C (A7 W35) Sound pressure level measured at 1m from the unit

112

Heating only EHYHBH05AV32 EHYHBH08AV32 710 x 450 x 240

m m %

Outdoor Units Dimensions Weight Nominal capacity Nominal input COP Operation range (ambient) Sound pressure / power level Refrigerant charge Piping connections

31.2 25~55

Residential, Commercial and Industrial

EVLQ08CV3 735 x 832 x 307

54 4.4 0.87 5.04

56 7.4 1.66 4.45 -25~25

48 / 61 1.45

49 / 62 1.6 1/4 5/8 20 1-phase / 230V / 50Hz 20


EHYH/K / EVLQ

Daikin Altherma hybrid heat pump system Part Number

Description

Trade Price

UK.HYBRID05B33

Hybrid 5kW pack

£3,400.00

EVLQ05CV3 EHYHBH05AV32 EHYKOMB33AA2 EKRUCBL2 EKHY093467 EKVK3A

Outdoor unit: 5kW, 1-phase, 230V Hydrobox: 5kW, 1-phase, 230V Hybrid combi boiler: 33/27kW Hybrid controller Pipe cover plate Hybrid valve pack

UK.HYBRID08B33

Hybrid 8kW pack

This pack contains:

£3,850.00

This pack contains: EVLQ08CV3 EHYHBH08AV32 EHYKOMB33AA2 EKRUCBL2 EKHY093467 EKVK3A

Outdoor unit: 8kW, 1-phase, 230V Hydrobox: 8kW, 1-phase, 230V Hybrid combi boiler: 33/27kW Hybrid controller Pipe cover plate Hybrid valve pack

Accessories: Accessory Ref

Description

Trade Price

K.HEATMET

Heat meter for domestic RHI (hybrid only) Class 3 heat meter delivered with body, digital interface and 2 temperature sensors Electric meter for RHI IEC Class 1 electric meter to measure the electricity consumption of the Daikin Altherma heat pump LPG conversion kit Flue adapter 80/125 PC cable – to upload field settings from PC to unit or spare controller Optional PCB kit for remote alarm monitoring, run and fault indication and solar interlock Optional second user interface or room thermostat Optional remote temperature sensor for outdoor temperature (see note) Optional remote temperature sensor for indoor temperature (see note) U-beams to mount the outdoor unit EVLQ05CV3 Drainpan and U-beams for outdoor unit EVLQ05CV3 Heater mat for drainpan (EKDP008C) Wall mounting bracket for outdoor unit Condensate drip tray for UK.CWB90-2 Outdoor unit guard

£170.00

EKHY075787 EKHY090717 EKPCCAB2 EKRP1HBA EKRUCL1 EKRSC1* KRCS01-1* EKFT008CA EKDP008C EKDPH008C UK.CWB90-2 UK.DT1 UK.CGM

£109.00

i) * Only one optional remote sensor can be installed

£20.00 £20.00 £180.00 £104.00 £94.00 £61.00 £46.00 £83.00 £116.00 £176.00 £36.00 £54.00 £296.00

HEATING

K.ELECMETV

Notes:

Features: > New and revolutionary hybrid heat pump system with higher efficiency and higher running cost savings than condensing boiler alone > Boiler can be converted to run on LPG > Delivered as a set including outdoor unit, indoor unit, boiler, controller and pipe cover plate > Flues ordered separately

Daikin Altherma hybrid heat pump system

Hybrid Tank Connection Kits Part Number

Description

Trade Price

EKEPHT3H

Daikin thermal store (EKHWP-B)

£174.00

This pack contains: 3 way valve (Honeywell) Tank sensor (HT + adapter) 2 x isolation valves T-piece EKHY3PART

Third party tank – dry pocket sensor

£145.00

This pack contains: 3 way valve (ESBE) Tank sensor (LT) EKHY3PART2

Third party tank – thermostat only

£175.00

This pack contains: 3 way valve (ESBE) Wire harness

Price List 2015

113


Daikin Altherma hybrid heat pump system

HEATING

Flue accessories (60/100)

114

Description

Quantity per pack

Part number

Trade Price

Horizontal flue kit 60/100

1

EKFGP1292

£43.00

Horizontal flue kit with low profile elbow 60/100

1

EKFGP1293

£52.00

Extension 60/100 x 500mm

1

EKFGP4651

£25.00

Extension 60/100 x 1000mm

1

EKFGP4652

£30.00

Elbow 60/100, 30 degrees

1

EKFGP4664

£33.00

Elbow 60/100, 45 degrees

1

EKFGP4661

£22.00

Elbow 60/100, 87 degrees

1

EKFGP4660

£22.00

Tee with inspection panel 60/100

1

EKFGP4667

£82.00

Wall bracket DN.100

25 pieces

EKFGP4631

£160.00

Plume Management Kit (PMK)

1

EKFGP1294

£36.00

Flue deflector

1

EKFGP1295

£14.00

Residential, Commercial and Industrial


Daikin Altherma hybrid heat pump system

Flue accessories (60/100)

(Continued) Quantity per pack

Part number

Trade Price

PMK elbow, 87 degrees

1

EKFGP1284

£12.00

PMK elbow, 45 degrees

2 pieces

EKFGP1285

£20.00

PMK extension, length 1000mm incl. bracket

1

EKFGP1286

£18.00

Vertical roof terminal 60/100

1

EKFGP6837

£60.00

Weather slate (plastic) 60/100 (25-45 degrees)

1

EKFGP7910

£27.00

18-22 degrees

1

EKFGS0518

£90.00

23-27 degrees

1

EKFGS0519

£90.00

43-47 degrees

1

EKFGS0523

£90.00

48-52 degrees

1

EKFGS0524

£90.00

53-57 degrees

1

EKFGS0525

£90.00

Weather slate flat aluminium 60/100

1

EKFGP6940

£20.00

Weather slate flat aluminium 60/100 (0 – 15 degrees)

1

EKFGP1296

£50.00

HEATING

Description

Weather slate 60/100

Price List 2015

115


HEATING

Heat emitters

Heat pump convectors can provide both heating and cooling if required and can be used with the Daikin Altherma heat pump to offer a compact and highly efficient solution: > D esigned to operate at low flow temperature (35째C) to optimise the efficiency of an air-water heat pump > Quiet operation and no draughts > Able to heat and cool > Available in 1.5 and 2kW > Ideal for meeting higher temperature star rating in MCS Heat Emitter Guide

116

Residential, Commercial and Industrial


FWX / EKV

Daikin heat pump convector Part number

Description

Nominal kW (heating/cooling)

Trade Price

FWXV15A + EKVKHPC

Cased, low wall mount type, 2-pipe*

1.5 / 1.2

£491.00

FWXV20A + EKVKHPC

Cased, low wall mount type, 2-pipe*

2.0 / 1.7

£528.00

Nominal capacity based on following conditions: Heating: indoor temp, 20°CDB; entering water temp. 45°C, water temperature drop 5°C. Cooling: Indoor temp. 27°CDB; entering water temp. 7°C, water temperature rise 5°C.

Notes:

> The highly efficient, low noise Daikin heat pump convector is designed to provide the maximum comfort and high efficiency in combination with Daikin Altherma heat pumps > The heat pump convector improves system efficiency compared to a combined under floor heating and radiator system and to a fan coil heating system > The Daikin heat pump convector has been designed to work effectively at low temperatures, while retaining a compact size compared to an equivalent output radiator sized for 45°C > The heat pump convector can easily replace existing heat emitters > The unit is very quiet in operation and is ideal for bedroom applications > The unit has a quiet operation mode which can be selected using the remote controller > The sound levels are as low as 18dB(A) on 2kW system and 12dB(A) on 1.5kW system on the quiet mode > Daikin heat pump convectors offer a solution combined with UFH systems to provide heat in areas where UFH is difficult to integrate > It is designed to support heating only and heating / cooling applications > When combined with Daikin Altherma outdoor units, the heat pump convectors can be linked together for total system control, additional comfort and increased efficiency > Additional third party controls are needed to link simple fan coil systems with Daikin Altherma heat pumps > Delivered with individual controller and with 2-way valve > Drain pan is included

i) * Please note that EKVKHPC (2 way valve) needs to be ordered as a separate item, but price shown includes the value of this part

HEATING

Features:

Price List 2015

117


HEATING

Solar thermal

Daikin solar systems maximise the use of renewable free energy from the sun through high efficiency flat plate collectors. The Daikin solar thermal system is available in drainback and pressurised options and is designed to work in conjunction with Daikin Altherma air-water heat pumps for maximum efficiency. Solar panels are Solar Keymark approved and eligible for the Domestic RHI. Drainback solar system

Pressurised solar system

> T he drainback solar system is a low maintenance system which does not need antifreeze agents

> T he pressurised solar system transfers heat to the unvented cylinder via a specially designed heat exchanger kit. This allows the entire cylinder to be heated by solar energy

> I t consists of an unpressurised thermal store which can be combined with Daikin Altherma heat pumps or another auxiliary heat source > W ater in the store is pumped to the solar panels, heated and returns to stratify in the Daikin thermal store > W hen solar energy is not available, the solar collectors empty and water drains back to the store

> During solar heating, the heat pump is disabled to ensure maximum efficiency

Standalone solar system > T he standalone solar system combines a pressurised solar system and a twin-coil unvented cylinder and is designed to be combined with an auxiliary gas boiler > Ideal for on-gas retrofit applications

Solar pressurised

118

Solar drainback

Residential, Commercial and Industrial


Solar panel EKSV / EKSH

Solar panel

Type Dimensions Height x Width x Depth Weight Max operating pressure Max standstill temp Information for SAP assessors and for MCS installers

mm kg Bar °C

Gross / net aperture area Zero loss efficiency Heat loss coefficient (a1) Heat loss coefficient (a2)

m2 W/m2.K W/m2.K2

Solar pump station

Solar controller

DHW Thermal Store

EKSV21P Vertical 2000x1006x85 35 6 200

EKSV26P Vertical 2000x1300x85 42 6 200

EKSH26P Horizontal 1300x2000x85 42 6 200

2.0 / 1.8 0.784 4.25 0.0072

2.6 / 2.36 0.784 4.25 0.0072

2.6 / 2.36 0.784 4.25 0.0072

Solar pump station EKSRD / EKSRP System Dimensions Height x Width x Depth Power supply Solar pump Max pump power consumption Max operating pressure Max pump capacity Temperature range Connections

mm

W Bar m3/h °C -

EKSRDS1A pressurised 410x240x130 230 / 50Hz Grundfos solar 25-65 130 52 6 2 0-120 (160 short term) 1¼” female for Ø 22 clamping ring bolt (x4)

EKSRPS3B drainback 230x815x142 230 / 50Hz Grundfos UPS0 15-65 (x2) 120 -

Dimensions Power supply Max electric consumption Display

Height x Width x Depth

mm W

EKSR3PA

-

332x230x145 230 / 50Hz 2 Plain text

230 / 50Hz 2 Plain text

EKHWP300B

EKHWP500B

300 59 359 1640x615x595 85 1.4

500 93 593 1640x790x790 85 1.4

HEATING

Solar controller EKSR

DHW Thermal Store EKHWP Storage capacity Weight (empty) Weight (filled) Dimensions Height x Width x Depth Max storage temp Heat loss at 60°C Coil material Potable water capacity Max operating pressure (potable water) DHW coil area Information for SAP assessors and for MCS installers

litres kgs kgs mm °C kWh/24h

Stainless Steel 1.4404 litres Bar m2

27.9 6 5.8

29.0 6 6.0

Total volume (V) Dedicated solar volume (Vs) Surface area solar heat exchange coil Heating coil capacity Heating coil area Pipe connections

litres litres m2 litres m2

300 300 N/A 13.2 2.7

500 500 N/A 18.5 3.8

Cold and hot water Heating flow / return Solar Thermal output data

Inches Inches Inches

Volume of hot water at given draw-off rate; without reheating (inlet = 10 °C / outlet = 40 °C / store = 50 °C) Reheat time (Wh) at given draw-off volume (inlet = 10 °C / outlet = 40 °C / store = 50 °C)

litres

8 l/min = 184 12 l/min = 153

8 l/min = 364 (1) 12 l/min = 318 (1)

mins

With 8kW heat pump 90 litres = 30 140 litres = 45 EKHWP300B

With 16kW heat pump 90 litres = 17 140 litres = 25 EKHWP500B

ERLQ004-8 EKDVCPLT3HX EKBH3S ERSQ011-16 EKEPHT3H 16 51 35

ERLQ011-16 EKDVCPLT5H EKBH3S ERSQ011-16 EKEPHT5H 16 51 35

DHW Thermal store combination Daikin Altherma LT Connection kit (2) Immersion heater (required) Daikin Altherma HT Connection kit Immersion heater (optional) 1. with immersion heater

1” outer thread 1” female / 1” male 1” internal thread

2. connection kits include 3WV, sensors and isolation valves

Price List 2015

119


Daikin solar thermal system

Solar panels, fixings and installation kits (common components) Description

Part number

Trade Price

Solar panel (vertical) – standard (2000 x 1300 x 85mm), aperture area 2.35m2, weight 42kg, water content 1.7 L. Max. 6 bar

EKSV26P

£404.00

EKSV21P

£338.00

EKSH26P

£415.00

Kit to couple 2 solar panels Mounting profile connector, expansion joints and double clamping blocks

162016-RTX

£35.00

Mounting rail for vertical panels Consisting of mounting profile rails and solar panel securing ties

162066 For EKSV21P (Was 162013)

£24.00

162067 For EKSV26P (Was EKSFIXMP130)

£30.00

162068 For EKSH26P (Was EKSFIXMP200)

£42.00

162036-RTX

£69.00

164723

£40.00

164703-RTX

£50.00

Note: Pressurised solar max 3 panels, drainback max 5 panels

Solar panel (vertical) – small (2000 x 1006 x 85mm), aperture area 1.79m2, weight 35kg, water content 1.3 L. Max. 6 bar Note: Pressurised solar max 3 panels, drainback max 5 panels

Solar panel (horizontal) – standard (1300 x 2000 x 85mm), aperture area 2.35m2, weight 42kg, water content 2.1 L. Max. 6 bar

HEATING

Note: For pressurised systems only

Note: Different for standard and small panels

4x Support hooks for high profile tiles 4 double height-adjustable roof ties including fixing material for one solar panel Note: Was EKSFIXADP

4x Support hooks for flat tiles (slate) 4 roof ties for flat roofing, e.g. slate, for one solar panel Note: Was EKSFIXADS

4x Support hooks for curved roofings Including fixing material for one solar panel Note: Was EKSFIXWD

120

Residential, Commercial and Industrial


Daikin solar thermal system

Solar panels, fixings and installation kits (common components) Description

Part number

Trade Price

4x Support hooks for sheet metal roofs Including fixing material for one solar panel

164704-RTX

£47.00

162019 For EKSV26P

£256.00

162017 For EKSV21P

£426.00

162020 For EKSV26P

£199.00

162018 For EKSV21P

£190.00

162058

£382.00

162059

£152.00

162060

£181.00

162061

£125.00

164110-RTX

£11.00

EKRP1HBA

£104.00

Note: Was EKSFIXBD

In-roof installation kit for 2x vertical panels For two solar panels, covering sheets complete with mounting material. Minimum roof angle 15° Note: Different for standard and small panels

In-roof extension kit for 1 additional vertical panel For one further solar panel, covering sheets complete with mounting material. Minimum roof angle 15° Note: Different for standard and small panels

Flat roof kit for 2x vertical panels Preassembled system for quick and easy assembly, with incremental adjustment of solar panel inclination between 30-60 degrees

Flat roof extension kit for 1 additional vertical panel Preassembled system for quick and easy assembly, with incremental adjustment of solar panel inclination between 30-60 degrees Note: For EKSV26P only

Flat roof kit for 1 horizontal panel Preassembled system for quick and easy assembly, with incremental adjustment of solar panel inclination between 30-60 degrees Note: For EKSH26P only

Flat roof extension kit for 1 additional horizontal panel Preassembled system for quick and easy assembly, with incremental adjustment of solar panel inclination between 30-60 degrees Note: For EKSH26P only

Connection cable to disable heat pump The connection cable is required to connect the solar priority PCB kit to heat pump Note: Need to order EKRP1HBA with this part Was EKS164110

Solar priority PCB kit This enables an interlock between the Daikin solar controller and Altherma heat pumps Note: Need to order 164110-RTX with this part

Price List 2015

121

HEATING

Note: For EKSV26P only


Daikin solar thermal system

Solar pressurised accessories Description

Part number

Trade Price

Solar controller Unit ready to plug in (230V), easy to wire and fit. Wall mounted digital differential temperature control system, return flow and storage tank temperature sensors are included

EKSR3PA

£191.00

Pump station Consisting of: Pipe connection (diameter 22mm) including pipe compression fittings and support sleeves (5x), flow regulator with 2 x KFE valves, integrated air separator, ball valves with integrated backflow preventor, Grundfos Solar 25-65 pump, safety group with pressure gauge, including insulation and mounting accessories

EKSRDS1A

£284.00

Flow sensor for energy metering Flow sensor for energy monitoring to enable automatic pump speed control to maximise efficiency by measuring the flow volume and flow temperature

164116

£75.00

Hydraulic connection kit (pressurised) Connection kit for pressurised only, includes connection to solar panel, 2m UV resistant heat insulation for the external area and solar panel temperature sensor

EKSRCP

£112.00

Connection pipe for solar panel rows Connection kit for connecting two rows of collectors one above the other. Consisting of solar panel mounting material, equipotential bonding clamps, end caps, connecting brackets and 1m thermally insulated piping

162045

£75.00

162052-RTX

£70.00

Thermostatic Mixing Valve Thermal safety device for DHW outlet with a setting range from 35-60°C

156015 + 156016

£65.00 + £27.00

15m solar pressurised pipe Pre-insulated stainless steel flexible pipework with sensor cable, order with fittings as shown

162073 + 162075 Up to 3 panels (DN16)

£240.00 + £34.00

Note: Order connection pack separately 162073 + 162075 was 162021-RTX 162074 + 162076 was 162026-RTX

162074 + 162076 4-5 panels (DN20)

£350.00 + £50.00

Solar pipe connectors Connectors to fit 2 pipes together for extension of solar pipe

162071 Up to 25m (DN16)

£24.00

162072 Up to 25m (DN20)

£20.00

162050 25 litre

£56.00

162051-RTX 35 litre

£144.00

EKSOLHW + EKUHW2WB

£533.00

Note: For use with EKHWSU & EKSOLHW only

Note: Was EKSFLP12A

HEATING

Note: Was EKSCONLCP Antifreeze fluid (glycol, 20L) 20L of pre-mixed solar fluid in a canister, SOL 5F. Functional range up to -28°C Note: Was EKSGFL

Note: 162071 was 162027-RTX 162072 was 162028-RTX

Solar expansion vessel Bracket and flexi hose included for installation

Solar connection kit for EKHWSU cylinder for connecting to solar panels A specially designed kit transfers solar heat into the Daikin Altherma hot water cylinder via an external heat exchanger, which allows the entire content of the cylinder to be heated efficiently with solar heat. Price shown includes EKUHW2WB 2-way valve. Delivered with EKRP1HBA PCB adaptor Note: For use with EKHWSU only

122

Residential, Commercial and Industrial


Daikin solar thermal system

Solar drainback accessories Description

Part number

Trade Price

Solar controller and pump station Unit ready to plug in (230V), with digital differential temperature control system, return flow and storage tank temperature sensors and operating pump

EKSRPS3B

£416.00

Solar connection pipe Ready to plug in connection pipe between the solar panel and the pump station, consisting of thermally insulated flow and return lines with integrated sensor cable. Available in 15 and 20m lengths

164732 15m length

£94.00

Note: 164732 was EKSCON15 164733 was EKSCON20

164733 20m length

£112.00

Solar connection pipe extension Ready to plug in, including fitting materials and connection fittings. Available in 2.5, 5 and 10m lengths

164261-RTX 2.5m

£59.00

164262-RTX 5m

£67.00

164263 10m

£88.00

164264

£74.00

Copper pipe connection kit 164232 Connection kit when connecting onto copper pipe (if Daikin drainback pipe is not used). Consisting of 2m flow and return pipes, push-fit coupling onto 15mm and 18mm copper pipe

£54.00

Solar panel row connection kit Connection kit for connecting two rows of collectors one above the other. Consisting of solar panel mounting material, equipotential bonding clamps, end caps, connecting brackets and 1m thermally insulated piping

162035-RTX

£65.00

EKSRCRP Brick red

£154.00

EKSRCAP Anthracite

£154.00

162037-RTX

£100.00

Note: 164261-RTX was EKSCONX25 164262-RTX was EKSCONX50 164263 was EKSCONX100

Max. length

2 3 4 5

45m 30m 17m 15m

Solar flow pipe extension UV resistant thermally insulated, length L = 8m, including cable connection fitting for the solar panel sensor line

HEATING

Maximum possible length of the connection pipe Number of solar panels

Note: Was EKSCONXV80

Note: Was EKSCONRVP

Hydraulic connection kit (on-roof) Connection kit for drainback (on-roof ), includes connection to solar panel, pitched roof flashing, 2m UV resistant insulation and solar panel temperature sensor Available in Anthracite or Brick red

Hydraulic connection kit (in-roof) NEW! Connection kit for drainback (in-roof ), includes connection to solar panel and solar panel temperature sensor

Price List 2015

123


Daikin solar thermal system

Solar drainback accessories

(Continued)

Description

Part number

Trade Price

Hydraulic connection kit (flat roof) NEW! Connection kit for drainback (flat roof ), includes connection to solar panel, flat roof penetration, 8.5m UV resistant insulation and solar panel temperature sensor

162038-RTX

£194.00

Gravity break set Avoids thermal heat loss from thermal store due to thermo-siphon effect. Advised when piping from heat exchanger is not making a down ward bend at the tank

165070

£8.00

Solar flow setter Flow regulating valve with flow indicator (2-16 l/min). For balancing solar flow in cascade thermal store installations

164102-RTX

£53.00

165113

£79.00

Note: For use only with EKHWP* only

Secondary circulation kit Connection kit for secondary hot water connections

HEATING

Note: For use with EKHWP* only

Daikin solar thermal system

Thermal store for Daikin Altherma High and Low Temperature This is a hot water thermal storage tank and provides instantaneous hot water. The tank serves as a heat storage medium. It can be heated by both Daikin Altherma heat pumps and solar energy. Description

Part number

Trade Price

EKHWP300B with connection kit for ERSQ011-016

EKHWP300B + EKEPHT3H

£1,159.00

EKHWP500B with connection kit for ERSQ011-016

EKHWP500B + EKEPHT5H

£1,409.00

EKHWP300B with connection kit for ERLQ004-008 (Heating / cooling) and 3kW immersion heater

EKHWP300B + EKDVCPLT3HX + EKBH3S

£1,315.00

EKHWP500B with connection kit for ERLQ011-016 (Heating only) and 3kW immersion heater

EKHWP500B + EKDVCPLT5H + EKBH3S

£1,595.00

Connection elbow enables easy filling and draining of the storage tank

165210

£21.00

Fill and drain connection

165215

£23.00

Thermal store (EKHWP***B) combination with Daikin Altherma High Temperature

Thermal store (EKHWP***B) combination with Daikin Altherma Low Temperature

Note: It is recommended that 165210 and 165215 are ordered with every thermal store

124

Residential, Commercial and Industrial


Daikin solar thermal system

Solar standalone accessories The standalone pressurised solar system is designed for use with auxiliary gas boiler and twin coil cylinder. Available in predefined on-roof and in-roof packs (see page 131) Description

Part number

Trade Price

Solar panel (vertical) – small (2006 x 1006 x 85mm), aperture area 1.79m2, weight 35kg, water content 1.3 L. Max. 6 bar

EKSV21P

£338.00

Mounting rail for small panels Consisting of mounting profile rails and securing ties

162066

£24.00

162036-RTX

£69.00

164723

£40.00

Pump station Consisting of: Pipe connection (diameter 22mm) including pipe compression fittings and support sleeves (5x), flow regulator with 2 x KFE valves, integrated air seperator, ball valves with integrated backflow preventor, Grundfos Solar 25-65 pump, safety group with pressure gauge, including insulation and mounting accessories

EKSRDS1A

£284.00

Hydraulic connection kit (pressurised) Connection kit for pressurised only, includes connection to solar panel, 2m UV resistant heat insulation for the external area and solar panel temperature sensor

EKSRCP

£112.00

Solar controller for standalone solar Wall mounted, small and compact. Easy to use solar controller with back-lit graphical illuminated display. Auxiliary heat source timer and pump speed control

UK.SOLCTRBS4

£191.00

FKU-HWS200TC 200L

£500.00* Sell out price

FKU-HWS250TC 250L

£525.00*

FKU-HWS300TC 300L

£570.00*

Note: Was 162013

4x Support hooks for high profile tiles 4 double height-adjustable roof ties including fixing material for one solar panel Note: Was EKSFIXADP

4x Support hooks for flat tiles (slate) 4 roof ties for flat roofing, e.g. slate, for one solar panel

Note: To control auxiliary gas boiler only

Twin coil solar cylinder Unvented stainless steel cylinder. Designed for gas boiler auxiliary heating and solar hot water connections. Delivered with full G3 compliance kit including 2-port motorised valve (except expansion vessel - field supply)

Note: Further standalone solar components are available to complete the standalone system (see pages 120-122) * Special offer for limited period. New discounted prices

Price List 2015

125

HEATING

Note: Was EKSFIXADS


Selecting the right solar system Daikin have a full range of solar thermal solutions including Drainback and Pressurised solutions to suit many installation requirements. Solar systems are available to work with heat pumps or with boilers and offer enhanced DHW energy savings. Use the table below to help select the right kind of solar system for your Daikin heat pump or your existing boiler.

Solar system

Auxiliary heat source

HEATING

Tank

Drainback

Pressurised

HT or LT Heat Pump

LT Heat Pump

Boiler

Thermal Store

Single coil + solar kit

Twin coil

(EKHWP)

(EHHWSU + EKUHW2WB)

(FKU)

Vertical 2.6m2

Vertical 2.6m2

Horizontal 2.6m2

Vertical 2.0m2

Panel orientation and size

On-roof

3

(page 128)

In-roof

3

(page 128)

Flat roof

3

(page 128)

126

Residential, Commercial and Industrial

3

(page 129)

3

(page 130)

3

(page 130)

3

3

(page 129)

(page 131)

7

(page 131)

3

(page 130)

3 7


Selecting the right solar pack Daikin offer solar systems in ready to order packs with all the key components include. After deciding between drainback or pressurised solar, use this table to select the right solar pack for your project.

Daikin solar thermal system

Solar packs – quick selection table Orientation

Fixing type

Tile

Roof cowl

1 panel pack

2 panel pack

3 panel pack

4 panel pack

5 panel pack

Vertical

On-roof

Profiled tile

Anthracite

UK.SP1VPDBA

UK.SP2VPDBA

UK.SP3VPDBA

UK.SP4VPDBA

UK.SP5VPDBA

Slate/flat tile

Anthracite

UK.SP1VSDBA

UK.SP2VSDBA

UK.SP3VSDBA

UK.SP4VSDBA

UK.SP5VSDBA

Profiled tile

Red

UK.SP1VPDBR

UK.SP2VPDBR

UK.SP3VPDBR

UK.SP4VPDBR

UK.SP5VPDBR

Slate/flat tile

Red

UK.SP1VSDBR

UK.SP2VSDBR

UK.SP3VSDBR

UK.SP4VSDBR

UK.SP5VSDBR

In-roof

Profiled/slate/ flat tile

-

-

UK.SP2VIDBA

UK.SP3VIDBA

UK.SP4VIDBA

UK.SP5VIDBA

Flat-roof

-

-

UK.SP1VADBA

UK.SP2VADBA

UK.SP3VADBA

UK.SP4VADBA

UK.SP5VADBA

On-roof

Profiled tile

-

UK.SP1VPP

UK.SP2VPP

UK.SP3VPP

-

-

Slate/flat tile

-

UK.SP1VSP

UK.SP2VSP

UK.SP3VSP

In-roof

Profiled/slate/ flat tile

-

-

UK.SP2VIP

UK.SP3VIP

Flat-roof

-

-

UK.SP1VAP

UK.SP2VAP

UK.SP3VAP

On-roof

Profiled tile

-

UK.SP1HPP

UK.SP2HPP

UK.SP3HPP

Slate/flat tile

-

UK.SP1HSP

UK.SP2HSP

UK.SP3HSP

Flat-roof

-

-

UK.SP1HAP

UK.SP2HAP

UK.SP3HAP

On-roof

Profiled tile

-

UK.V21PP1

UK.V21PP2

UK.V21PP3

-

-

Slate/flat tile

-

UK.V21SP1

UK.V21SP2

UK.V21SP3

Profiled/slate/ flat tile

-

-

UK.V21IP2

UK.V21IP3

Pressurised (For Daikin Altherma LT)

Vertical

Horizontal

Pressurised (Standalone)

Vertical

In-roof

Price List 2015

HEATING

System type Drainback (For Daikin Altherma HT and LT)

127


Daikin solar thermal system

Solar packs – drainback system for Daikin Altherma High Temperature and Low Temperature Vertical on-roof profiled tile pack Vertical pack order reference This pack contains: Vertical flat plate collector Roof brackets for concrete / profiled x 4 Mounting rail for panel Hydraulic connection kit (on-roof ) including cowl in either: Solar controller & pump station* Coupling kit for multiple panels Connection cable to disable heat pump Pack price

Part number

Anthracite / Red

EKSRPS3B 162016-RTX 164110-RTX

Vertical on-roof slate tile pack Vertical pack order reference This pack contains: Vertical flat plate collector Roof brackets for slate / flat tiles x 4 Mounting rail for panel Hydraulic connection kit (on-roof ) including cowl in either: Solar controller & pump station* Coupling kit for multiple panels Connection cable to disable heat pump Pack price

Part number

Anthracite / Red

Vertical in-roof pack

HEATING

EKSV26P 162036-RTX 162067 EKSRCAP / EKSRCRP

Vertical pack order reference This pack contains: Vertical flat plate collector Mounting rail for panel Hydraulic connection kit (in-roof ) Solar controller & pump station* Coupling kit for multiple panels In-roof kit for 2x vertical panels In-roof extension kit for 1x panel Connection cable to disable heat pump Pack price

Vertical flat roof pack Vertical pack order reference This pack contains: Vertical flat plate collector Mounting rail for panel Hydraulic connection kit (flat roof ) including flat roof penetration Solar controller & pump station* Coupling kit for multiple panels Solar flat roof kit for 2xV26P Solar flat roof kit for additional V26P Connection cable to disable heat pump Pack price

1 panel pack

2 panel pack

3 panel pack

4 panel pack

5 panel pack

UK.SP1VPDBA/R Quantity 1 1 1 1

UK.SP2VPDBA/R Quantity 2 2 2 1

UK.SP3VPDBA/R Quantity 3 3 3 1

UK.SP4VPDBA/R Quantity 4 4 4 1

UK.SP5VPDBA/R Quantity 5 5 5 1

1 0 1 £1,084.00

1 1 1 £1,622.00

1 2 1 £2,160.00

1 3 1 £2,698.00

1 4 1 £3,236.00

1 panel pack

2 panel pack

3 panel pack

4 panel pack

5 panel pack

UK.SP1VSDBA/R Quantity 1 1 1 1

UK.SP2VSDBA/R Quantity 2 2 2 1

UK.SP3VSDBA/R Quantity 3 3 3 1

UK.SP4VSDBA/R Quantity 4 4 4 1

UK.SP5VSDBA/R Quantity 5 5 5 1

EKSRPS3B 162016-RTX 164110-RTX

1 0 1 £1,055.00

1 1 1 £1,564.00

1 2 1 £2,073.00

1 3 1 £2,582.00

1 4 1 £3,091.00

Part number

1 panel pack

2 panel pack

3 panel pack

4 panel pack

5 panel pack

Quantity -

UK.SP2VIDBA/R Quantity 2 2 1 1 1 1 0 1 £1,686.00

UK.SP3VIDBA/R Quantity 3 3 1 1 2 1 1 1 £2,354.00

UK.SP4VIDBA/R Quantity 4 4 1 1 3 1 2 1 £3,022.00

UK.SP5VIDBA/R Quantity 5 5 1 1 4 1 3 1 £3,690.00

EKSV26P 164723 162067 EKSRCAP / EKSRCRP

EKSV26P 162067 162037-RTX EKSRPS3B 162016-RTX 162019 162020 164110-RTX

Part number

1 panel pack

2 panel pack

3 panel pack

4 panel pack

5 panel pack

EKSV26P 162067 162038-RTX

UK.SP1VADBA/R Quantity 1 1 1

UK.SP2VADBA/R Quantity 2 2 1

UK.SP3VADBA/R Quantity 3 3 1

UK.SP4VADBA/R Quantity 4 4 1

UK.SP5VADBA/R Quantity 5 5 1

1 0 1 0 1 £1,437.00

1 1 1 0 1 £1,906.00

1 2 1 1 1 £2,527.00

1 3 1 2 1 £3,148.00

1 4 1 3 1 £3,769.00

EKSRPS3B 162016-RTX 162058 162059 164110-RTX

Important: When installing an integrated Daikin Altherma HT and Daikin drainback solar system, the following accessories need to be ordered separately: EKHWP – Thermal store EKRP1HBA – Option PCB for use with Hydrobox for alarm monitoring (Solar priority PCB) EKSCON*** – Solar connection pipe * When installing an integrated ROTEX Gas Compact Unit and Daikin drainback solar system, order 164125 instead of EKSRPS3B

128

Residential, Commercial and Industrial


Daikin solar thermal system

Vertical on-roof profiled tile pack Vertical pack order reference This pack contains: Vertical flat plate collector Roof brackets for concrete / profiled tiles x 4 Mounting rail for panel Hydraulic connection kit Solar controller Solar pump station Flow sensor Solar fluid (20 litres) Coupling kit for multiple panels Solar expansion vessel (25 litres) Connection cable to disable heat pump Pack price

Vertical on-roof slate / flat tile pack Vertical pack order reference This pack contains: Vertical flat plate collector Roof brackets for slate / flat tiles x 4 Mounting rail for panel Hydraulic connection kit Solar controller Solar pump station Flow sensor Solar fluid (20 litres) Coupling kit for multiple panels Solar expansion vessel (25 litres) Connection cable to disable heat pump Pack price

Horizontal on-roof profiled tile pack Horizontal pack order reference This pack contains: Horizontal flat plate collector Roof brackets for concrete / profiled tiles x 4 Mounting rail for panel Hydraulic connection kit Solar controller Solar pump station Flow sensor Solar fluid (20 litres) Coupling kit for multiple panels Solar expansion vessel (25 litres) Connection cable to disable heat pump Pack price

Horizontal on-roof slate / flat tile pack Horizontal pack order reference This pack contains: Horizontal flat plate collector Roof brackets for slate/flat tiles x 4 Mounting rail for panel Hydraulic connection kit Solar controller Solar pump station Flow sensor Solar fluid (20 litres) Coupling kit for multiple panels Solar expansion vessel (25 litres) Connection cable to disable heat pump Pack price

Part number

EKSV26P 162036-RTX 162067 EKSRCP EKSR3PA EKSRDS1A 164116 162052-RTX 162016-RTX 162050 164110-RTX

Part number

EKSV26P 164723 162067 EKSRCP EKSR3PA EKSRDS1A 164116 162052-RTX 162016-RTX 162050 164110-RTX

Part number

EKSH26P 162036-RTX 162068 EKSRCP EKSR3PA EKSRDS1A 164116 162052-RTX 162016-RTX 162050 164110-RTX

Part number

EKSH26P 164723 162068 EKSRCP EKSR3PA EKSRDS1A 164116 162052-RTX 162016-RTX 162050 164110-RTX

1 panel pack

2 panel pack

3 panel pack

UK.SP1VPP Quantity 1 1 1 1 1 1 1 1 0 1 1 £1,302.00

UK.SP2VPP Quantity 2 2 2 1 1 1 1 1 1 1 1 £1,840.00

UK.SP3VPP Quantity 3 3 3 1 1 1 1 1 2 1 1 £2,378.00

1 panel pack

2 panel pack

3 panel pack

UK.SP1VSP Quantity 1 1 1 1 1 1 1 1 0 1 1 £1,273.00

UK.SP2VSP Quantity 2 2 2 1 1 1 1 1 1 1 1 £1,782.00

UK.SP3VSP Quantity 3 3 3 1 1 1 1 1 2 1 1 £2,291.00

1 panel pack

2 panel pack

3 panel pack

UK.SP1HPP Quantity 1 1 1 1 1 1 1 1 0 1 1 £1,325.00

UK.SP2HPP Quantity 2 2 2 1 1 1 1 1 1 1 1 £1,886.00

UK.SP3HPP Quantity 3 3 3 1 1 1 1 1 2 1 1 £2,447.00

1 panel pack

2 panel pack

3 panel pack

UK.SP1HSP Quantity 1 1 1 1 1 1 1 1 0 1 1 £1,296.00

UK.SP2HSP Quantity 2 2 2 1 1 1 1 1 1 1 1 £1,828.00

UK.SP3HSP Quantity 3 3 3 1 1 1 1 1 2 1 1 £2,360.00

HEATING

Solar packs – pressurised system for Daikin Altherma Low Temperature

Important: Packs detailed above are for pressurised solar thermal systems for Daikin Altherma Low Temperature. When installing an integrated Daikin Altherma heat pump and pressurised Daikin solar thermal system, the following accessories need to be ordered separately: EKHWSU – Domestic hot water cylinder EKSOLHW – Solar kit for EKHWSU tank 1620** – Solar pressurised pipe and connectors

Price List 2015

129


Daikin solar thermal system

Solar packs – pressurised system for Daikin Altherma Low Temperature Vertical in-roof pack Vertical pack order reference This pack contains: Vertical flat plate collector Mounting rail for panel Hydraulic connection kit Solar controller Solar pump station Flow sensor Solar fluid (20 Litres) Coupling kit for multiple panels In roof kit for 2 x V26P In roof extension kit for additional V26P Solar expansion vessel (25 litres) Connection cable to disable heat pump Pack price

Vertical flat roof pack

HEATING

Vertical pack order reference This pack contains: Vertical flat plate collector Mounting rail for panel Hydraulic connection kit Solar controller Solar pump station Flow sensor Solar fluid (20 Litres) Coupling kit for multiple panels Solar flat roof kit for 2xV26P Solar flat roof kit for additional V26P Solar expansion vessel (25 litres) Connection cable to disable heat pump Pack price

Horizontal flat roof pack Horizontal pack order reference This pack contains: Horizontal flat plate collector Mounting rail for panel Hydraulic connection kit Solar controller Solar pump station Flow sensor Solar fluid (20 Litres) Coupling kit for multiple panels Solar flat roof kit for H26P Solar flat roof kit for additional H26P Solar expansion vessel (25 litres) Connection cable to disable heat pump Pack price

Part number

EKSV26P 162067 EKSRCP EKSR3PA EKSRDS1A 164116 162052-RTX 162016-RTX 162019 162020 162050 164110-RTX

Part number

EKSV26P 162067 EKSRCP EKSR3PA EKSRDS1A 164116 162052-RTX 162016-RTX 162058 162059 162050 164110-RTX

Part number

EKSH26P 162068 EKSRCP EKSR3PA EKSRDS1A 164116 162052-RTX 162016-RTX 162060 162061 162050 164110-RTX

(Continued)

2 panel pack

3 panel pack

UK.SP2VIP Quantity 2 2 1 1 1 1 1 1 1 0 1 1 £1,958.00

UK.SP3VIP Quantity 3 3 1 1 1 1 1 2 1 1 1 1 £2,626.00

1 panel pack*

2 panel pack

3 panel pack

UK.SP1VAP Quantity 1 1 1 1 1 1 1 0 1 0 1 1 £1,615.00

UK.SP2VAP Quantity 2 2 1 1 1 1 1 1 1 0 1 1 £2,084.00

UK.SP3VAP Quantity 3 3 1 1 1 1 1 2 1 1 1 1 £2,705.00

1 panel pack

2 panel pack

3 panel pack

UK.SP1HAP Quantity 1 1 1 1 1 1 1 0 1 0 1 1 £1,437.00

UK.SP2HAP Quantity 2 2 1 1 1 1 1 1 1 1 1 1 £2,054.00

UK.SP3HAP Quantity 3 3 1 1 1 1 1 2 1 2 1 1 £2,671.00

* Important: When ordering the vertical flat roof pack, please be aware the solar flat roof kit comes for 2 vertical panels, thus some wastage will occur (the wastage is not enough to be used for another panel). Important: Packs detailed above are for pressurised solar thermal systems for Daikin Altherma Low Temperature. When installing an integrated Daikin Altherma heat pump and pressurised Daikin solar thermal system, the following accessories need to be ordered separately: EKHWSU – Domestic hot water cylinder EKSOLHW – Solar kit for EKHWSU tank 1620** – Solar pressurised pipe and connectors

130

Residential, Commercial and Industrial


Daikin solar thermal system

Vertical on-roof profiled tile pack Vertical pack order reference This pack contains: Vertical flat plate collector (small panel) Roof brackets for concrete / profiled tiles x 4 Mounting rail for panel Hydraulic connection kit Solar controller (for auxiliary gas boiler) Solar pump station Solar fluid (20 litres) Coupling kit for multiple panels Solar expansion vessel (25 litres) Pack price

Vertical on-roof slate / flat tile pack Vertical pack order reference This pack contains: Vertical flat plate collector (small panel) Roof brackets for slate / flat tiles x 4 Mounting rail for panel Hydraulic connection kit Solar controller (for auxiliary gas boiler) Solar pump station Solar fluid (20 litres) Coupling kit for multiple panels Solar expansion vessel (25 litres) Pack price

Vertical in-roof pack Vertical pack order reference This pack contains: Vertical flat plate collector (small panel) Mounting rail for panel Hydraulic connection kit Solar controller (for auxiliary gas boiler) Solar pump station Solar fluid (20 litres) Coupling kit for multiple panels Solar expansion vessel (25 litres) In roof kit for 2 x V21P In roof extension kit for additional V21P Pack price

Part number

EKSV21P 162036-RTX 162066 EKSRCP UK.SOLCTRBS4 EKSRDS1A 162052-RTX 162016-RTX 162050

Part number

EKSV21P 164723 162066 EKSRCP UK.SOLCTRBS4 EKSRDS1A 162052-RTX 162016-RTX 162050

Part number

EKSV21P 162066 EKSRCP UK.SOLCTRBS4 EKSRDS1A 162052-RTX 162016-RTX 162050 162017 162018

1 panel pack

2 panel pack

3 panel pack

UK.V21PP1 Quantity 1 1 1 1 1 1 1 0 1 £1,144.00

UK.V21PP2 Quantity 2 2 2 1 1 1 1 1 1 £1,610.00

UK.V21PP3 Quantity 3 3 3 1 1 1 1 2 1 £2,076.00

1 panel pack

2 panel pack

3 panel pack

UK.V21SP1 Quantity 1 1 1 1 1 1 1 0 1 £1,115.00

UK.V21SP2 Quantity 2 2 2 1 1 1 1 1 1 £1,552.00

UK.V21SP3 Quantity 3 3 3 1 1 1 1 2 1 £1,989.00

2 panel pack

3 panel pack

UK.V21IP2 Quantity 2 2 1 1 1 1 1 1 1 0 £1,898.00

UK.V21IP3 Quantity 3 3 1 1 1 1 2 1 1 1 £2,485.00

HEATING

Solar packs – standalone pressurised system for use with auxiliary gas boiler

Important: Packs detailed above are not designed to be used with Daikin Altherma heat pumps. The above packs are designed to be used with an auxiliary gas boiler and twin coil cylinder. To complete the Daikin standalone pressurised solar system, please order twin coil cylinder (FKU-HWS***TC).

Price List 2015

131


HEATING

Underfloor heating

ROTEX underfloor heating system is designed to work seamlessly with the Daikin Altherma range to provide high heat pump efficiency and low surface temperatures for the most comfortable room climate. When partnered with heat pumps, UFH with low flow temperatures helps to achieve high heat pump efficiencies and even higher running cost savings. > E nergy saving and highly versatile, can be used with condensing boilers, heat pumps and solar systems > Simple installation with easy to lay components > System plates with excellent heat insulation properties and sound insulation properties > Additional energy benefits recognised in SAP and MCS > R otex Monopex is ideal for low temperature systems such as heat pumps and is available in a variety of pipe sizes > R otex System 70 is ideal for mixed UFH and radiator systems and commercial heating systems with primary flow temperatures 55 - 70°C

For information on Daikin’s underfloor heating design process go to page 135. 132

Residential, Commercial and Industrial


Underfloor heating system

Underfloor heating plates Protect system plates: Styrofoam nap-plates with a protective layer of deep-drawn polystyrene. Overlapping connection for easy fixing. Installation dimensions 122 x 120cm. Suitable for heating pipes with Ø 14 and 17mm. Rectangular or diagonal heating pipe installation. Spacing: Right-angled pipes: 75, 150, 225, 300mm. Diagonal pipes: 55, 110, 165, 220, 275, 330mm. Note: See page 137 for clip rail and staple systems. Quantity per pack

Part number

Trade Price

8 (11.71m2)

171040

£104.00

Protect-Integral 33-3 HKV Reduced number of naps for use in vicinity of heating manifolds and door passages

2 (2.88m2)

171043

£21.00

Protect 10 Height 28mm. Heat conduction resistance: 0.29 m2K/W. For constructions with increased load and several insulation layers

13 (19.03m2)

171041

£141.00

Protect 10 HKV Reduced number of naps for use in vicinity of heating manifolds and door passages

3 (4.32m2)

171044

£33.00

Protect Mini Height 24mm. Heat conduction resistance: 0.17 m2K/W. Only suitable for heating pipes 13mm and 14mm. For use in constructions with low construction height

10 (14.64m2)

171037

£91.00

Protect Mini Solo Height 17mm. Deep-drawn polystyrene plate but without heat and sound insulation. For use in constructions with low construction height

10 (14.64m2)

171038

£47.00

HEATING

Description Protect-Integral 33-3 Height 48mm. Heat conduction resistance: 0.75 m2K/W. Integrated heat and sound insulation Installation against heated rooms

Styrofoam nap-plate: With integrated connection technique for the system plates. Installation dimensions: 120 x 60cm. Suitable for heating pipe with Ø 14 and 17mm. Rectangular heating pipe installation. Spacing: 75, 150, 225, 300mm. Mono 15 Height 38mm. Heat conduction resistance: 0.43m²K/W Styrofoam system plate without noise insulation. For use in constructions with reduced construction height

20 (14.4m2)

171010

£110.00

Compact 45 Height 67mm. Heat conduction resistance: 1.28 m2K/W. Styrofoam system plate with increased heat insulation. Installation in constructions against unheated rooms and earth

11 (7.92m2)

171017

£90.00

Isodur plate Height 55mm Heat conduction resistance: 0.85m²K/W. Suitable for DUO 25 heating pipe Spacing: 200, 300, 400mm. For industrial buildings and large areas

14 (10.8m2)

171013

£80.00

171112 Monopex 14AL

£120.00

171113 DUO 17

£131.00

Dry system Secco: For dry construction, in profiled, galvanised sheet steel, suitable for Mono, Basic and Compact plate. Package contents: 120 x 37cm, Qty 8 / 40 x 37cm, Qty 6 Aluminium plate for Secco system

1 (5.35m2)

Price List 2015

133


Underfloor heating system

Heat emission plate Dual channel aluminium spreader plates for timber suspended or battened floor installations. For joists at 400mm centres. Plate dimensions 1000x390mm Description

Length

Part number

Trade Price

Spreader plates For Ø 17mm pipe

10 (3.9m2)

171141

£43.00

Underfloor heating system

Underfloor heating pipes

HEATING

Monopex heating pipes: Thick-walled, linked basic PE-X pipe with oxygen-tight barrier for Monopex low temperature underfloor heating systems. Description

Length

Part number

Trade Price

Monopex 14 PE-X 14 x 2 OD For Monopex underfloor heating system

120m

170008

£128.00

240m

170009

£255.00

Monopex 14 ALU thick-walled PE-X 14 x 2 Aluminium coating and PE external layer. For Monopex underfloor heating systems

120m

170604

£181.00

240m

170605

£360.00

Monopex 17 PE-X 17 x 2 OD For Monopex underfloor heating system

120m

170029

£142.00

240m

170028

£283.00

600m

170062

£705.00

120m

170030

£163.00

240m

170109

£325.00

400m

170108

£540.00

25m

170053 Ø 19/25mm

£15.00

25m

170098 Ø 16/21mm

£12.00

75m

170001 Ø 23/28mm

£47.00

120m

170068

£199.00

240m

170086

£398.00

120m

170601

£229.00

240m

170602

£457.00

200m

170050

£435.00

Monopex 20 PE-X 20 x 2 OD For Monopex underfloor heating system

Protective pipe Black corrugated pipe made of plastic as additional insulation in the area of the manifold and expansion joints

DUO heating pipes: Thick-walled linked PE-X basic pipe, with oxygen-tight barrier, and additional highly flexible PE ribbed pipe. For underfloor heating systems operated in direct combination with other heating surfaces, e.g. radiators. DUO 17 PE-X 17/12 x 2 OD pipe For system 70 underfloor heating & heating radiator connection Outer pipe Ø 17mm Inner pipe 12 x 2mm

DUO 17 ALU PE-X 17/12 x 2 With aluminium coating and PE external layer. For system 70 radiator connection and underfloor heating Outer pipe Ø 17mm Inner pipe 12 x 2mm

DUO 25 PE-X 25/18 x 2 OD For system 70 industrial underfloor heating

134

Residential, Commercial and Industrial


Underfloor heating system

Manifolds RMX manifold: RMX heating circuit manifold, for underfloor heating systems and radiators. Suitable for the smallest fitting heights. Buy clamping ring sets separately to suit pipe. Description

Quantity per pack

Part number

Trade Price

Manifold RMX 2-port

1

172702

£106.00

Manifold RMX 3-port

1

172703

£124.00

Manifold RMX 4-port

1

172704

£146.00

Manifold RMX 5-port

1

172705

£167.00

Manifold RMX 6-port

1

172706

£189.00

Manifold RMX 7-port

1

172707

£211.00

Manifold RMX 8-port

1

172708

£232.00

Manifold RMX 9-port

1

172709

£254.00

Manifold RMX 10-port

1

172710

£276.00

Manifold RMX 11-port

1

172711

£296.00

Manifold RMX 12-port

1

172712

£319.00

Manifold HKV 2-port

1

172502

£72.00

Manifold HKV 3-port

1

172503

£87.00

Manifold HKV 4-port

1

172504

£103.00

Manifold HKV 5-port

1

172505

£116.00

Manifold HKV 6-port

1

172506

£137.00

Manifold HKV 7-port

1

172507

£147.00

Manifold HKV 8-port

1

172508

£162.00

Manifold HKV 9-port

1

172509

£176.00

Manifold HKV 10-port

1

172510

£192.00

Manifold HKV 11-port

1

172511

£206.00

Manifold HKV 12-port

1

172512

£223.00

Manifold HKV 13-port

1

172513

£237.00

Manifold HKV 14-port

1

172514

£291.00

Kombi box Subdivision for distribution room-by-room and controller for max. 2 underfloor heating circuits with system 70 for DUO 17 heating pipe and optionally with a radiator complete in UP case incl. cover plates, without clamping ring set and actuator

1

172415

£95.00

HEATING

HKV heating circuit manifold, suitable for underfloor heating and radiators, with fast mounting system

Underfloor heating (UFH) design process To prepare an accurate bill of materials and quotation for your underfloor heating project, we need to carry out a detailed UFH design. This will take account of parameters including room heat losses, water flow temperature, floor construction, floor coverings and preferred manifold positions.

If you require an UFH design, please contact your sales representative or your local branch for assistance. To enable us to carry out the UFH design, you will need to submit: > Autocad drawings – floor plans and elevations > Completed Daikin UFH design request form (available from your local branch) Please allow up to 20 working days from submitting your drawings to receiving your quotation. Once you have placed an order for the UFH materials, we will send you the UFH design for your approval prior to shipping the materials. Price List 2015

135


Underfloor heating system

Manifold accessories Description

Quantity per pack

Part number

Trade Price

RMX actutator (230V) Actuator for RMX manifold and kombi box

1

175145

£18.00

HKV actuator (230V) Actuator for HKV manifold and kombi box

1

175110

£21.00

RMX connection set DUO17

2

170312

£8.00

RMX connection set Monopex 14

2

170314

£8.00

RMX connection set Monopex 17

2

170317

£7.00

RMX connection set DUO25

2

170318

£7.00

RMX connection set Monopex 20

2

170320

£7.00

RMX manifold isolating valves 1”

2

175514

£21.00

Coupling nipple (3/4”) for combination with 1703** clamping ring sets

2

177227

£8.00

Connection nipple (3/4” PEX x 1/2” male) for combination with 1703** clamping ring sets

2

177327

£6.00

HKV connection set DUO17

2

177012

£7.00

HKV connection set Monopex 14

2

177014

£7.00

HKV connection set Monopex 17

2

177017

£7.00

HKV connection set DUO25

2

177018

£7.00

HKV connection set Monopex 20

2

177020

£8.00

Connection kit for HKV2 to HKV14 Contains 2 x isolating valves (1”), 2 x connection pieces, 2 x filling and draining valves and 2 x temperature gauges

1

175510

£68.00

Manifold cabinet up to 7-port

1

174110

£126.00

Manifold cabinet up to 10-port

1

174115

£139.00

Manifold cabinet up to 14-port

1

174120

£159.00

HEATING

Clamping ring set on RMX heating circuit manifold for flow and return per heating circuit

Clamping ring set on HKV heating circuit manifold for flow and return, per heating circuit

136

Residential, Commercial and Industrial


Underfloor heating system

Insulating strips and installation accessories Quantity per pack

Part number

Trade Price

Tacker gun Tacker gun for 60mm pipe staples. The tacker gun can be used to secure pipe directly to floor insulation

1

171134

£200.00

Pipe staples 60mm pipe staples for use with tacker gun (171134) and high density insulation with DPM

300

171137

£35.00

Clip rail 1m pieces, pipe centres 50mm

100m

171224

£271.00

Clip rail nail KN06

100 pieces

171127

£27.00

Edging strip For cement or anhydrite screed. PE foam with welded foil, height 150mm, 8mm thick

25m

171101

£16.00

Edging strip For free-flowing screed PE foam with welded foil, and additional sealing cord. Height 150mm, 10mm thick

25m

171126

£30.00

Combined pipe cutters and stripping pliers RAZ1

1

171110

£53.00

Pipe decoiler RAW 240 for <240m

1

171006

£525.00

Pipe clips

50

171117 For Ø 17-20mm

£6.00

171125 For Ø 25mm

£9.00

171142 For Ø 14-18mm

£10.00

171143 For Ø 20-22mm

£13.00

Pipe bend This is recommended to facilitate the bend of the pipe up-to the manifold

HEATING

Description

10

Price List 2015

137


Underfloor heating system

Underfloor heating room controls Basic range

HEATING

Note: Cannot be combined with advanced range (see page 139) Description

Quantity per pack

Part number

Trade Price

RTR5 control Electronic room temperature control (230V)

1

175117

£21.00

RTK control Room temperature control with heating/cooling function

1

175125

£30.00

FRT wireless control Wireless room temperature control

1

175120

£77.00

Single FRT wireless receiver Receiver FEM1 for 1x FRT

1

175121

£86.00

Multiple FRT wireless receiver Receiver FEM4 for 4x FRT

1

175122

£152.00

Underfloor heating system

Wiring centres and accessories Basic range Note: Cannot be combined with advanced range (see page 139) Description

Quantity per pack

Part number

Trade Price

Wiring box for 14x SAT Wiring box 6xRTR and max 14xSAT

1

175131

£62.00

Wiring box extension for 4x SAT Wiring box extension for 175131. Additional 2xRTR and Max 4x SAT

1

175132

£26.00

Pump module for wiring box Provides on/off signal to the heat source

1

175134

£62.00

Note: Can only be combined with wiring box 175131. One required per UFH manifold

138

Residential, Commercial and Industrial


Underfloor heating system

Underfloor heating room controls Advanced range Modern aesthetics, easy to install and greater user comfort Note: Cannot be combined with basic range (see page 138) Description

Quantity per pack

Part number

Trade Price

Room thermostat (wired) NEW! - Electronic room temperature control (5V) - Adjustment range 5-26C - D isplay of heating and cooling mode (red and blue LED)

1

175139

£27.00

Room thermostat (RF) NEW! - Electronic room temperature control - Adjustment range 5-26C - Solar powered (no batteries required) - A llow 24 hours to charge before commissioning

1

175142

£128.00

Underfloor heating system

Wiring centres and accessories Advanced range Modern aesthetics, easy to install and greater user comfort

Description

Quantity per pack

Part number

Trade Price

Wiring centre NEW! - 6 channels - 4 actuators (230 V) per channel - Automatic heating/cooling switchover

1

175140

£121.00

Wiring centre NEW! - 2 channels - 4 actuators (230 V) per channel - Automatic heating/cooling swtichover

1

175141

£60.00

Wiring centre (RF) NEW! - 6 channels - 4 actuators (230 V) per channel - Automatic heating/cooling switchover - I ncluding antenna for wireless communication

1

175143

£227.00

Wiring centre (RF) NEW! - 2 channels - 4 actuators (230 V) per channel - Automatic heating/cooling swtichover - I ncluding antenna for wireless communication

1

175144

£151.00

Wiring centre power module NEW! To supply power to the wiring centres, including: - P ump input/output for heating and cooling

1

175137

£113.00

Wiring centre clock module NEW! - Removable clock module - 2 setback timers for heating circuits

1

175138

£60.00

Note: To be combined with the wiring centre power module

Price List 2015

139

HEATING

Note: Cannot be combined with basic range (see page 138)


HEATING


Daikin UK Price List 2015

Refrigeration CVP 142 Booster Unit

143

ZEAS 144

REFRIGERATION

Multi-ZEAS 145

Scotland Region 0845 641 9330

Northern Region 0845 641 9340

Midlands Region 0845 641 9370

Western Region 0845 641 9320

North London 0845 641 9360

South London 0845 641 9355


LRYEQ-AY1

CVP CVP is a compact, low noise system which integrates high and low temperature refrigeration along with heating and cooling into one system. A total solution helping retailers save energy and the environment.

Benefits > Optimum efficiency: inverter driven outdoor units match system output to the actual demand in order to reach optimum efficiency under all conditions > Connection flexibility: supports a wide range of refrigeration and cooling cases > Save energy: by recovering the heat extracted from the connected refrigeration appliances and using sophisticated controls, energy savings of up to 50% can be reached compared with conventional 3P systems > Small footprint: along with reduced piping the compact CVP is ideal for densely populated urban areas > Flexible: VRV (Variable Refrigerant Volume) technology for flexible application range. Full range of VRV fan coils available together with air curtains > Minimal noise: lowest operating sound level including night set back function

HEAT RECOVERY

-35°C

REFRIGERATION

-10°C

Indoor units Casing Dimensions Weight Heat exchanger Fan

Fan motor Compressor

Operation range Refrigerant

Refrigerant oil

Power supply Voltage range

LRYEQ16AY1 Colour HeightxWidthx Depth Type Type Quantity Air flow rate Cooling Output Drive N° of compressors Type Piston displacement Speed Output Starting method Frequency ON/OFF Evaporator Cooling Type Charge Control Type Charged volume

mm kg

Nom.

m³/min W

m³/h rpm W

Min.~Max.

Phase / Frequency / Voltage Min. Max.

°CDB kg

l

Hz / V % %

Trade Price (1) Compressor 1 | (2) Compressor 2 | (3) Compressor 3 | (4) Factory charge of unit

142

Residential, Commercial and Industrial

Ivory white (Munsell code: 5Y7.5/1) 1,680x1,240x765 370 Cross fin coil Propeller fan 2 230 750 Direct drive 3 Hermetically sealed scroll compressor 13.34 / 10.53 / 10.53 6,300 / 2,900 / 2,900 2,500 / 3,600 / 4,500 Direct on line (inverter driven) Less than 6 times/hour -20 @ 0~10 R-410A 11.5 Electronic expansion valve Daphne FVC68D 1.7 (1) 2.1 (2) 2.1 (3) 4.0 (4) 3~ / 50 / 380-415 -10 10 £14,015.00


LCBKQ-AV19

Booster unit Benefits > A booster unit allows to connect freezer showcases/ rooms to ZEAS and Conveni-Pack outdoor units > R educed piping requirements, from 4 to 2 pipes, compared to a conventional system > L ow sound mode available reducing sound emissions significantly

Booster with ZEAS:

MEDIUM + LOW TEMPERATURE refrigeration -19°C 2°C

-20°C

8°C

Booster

Booster

Booster with Conveni-Pack:

MEDIUM + LOW TEMPERATURE refrigeration + space air conditioning + Biddle air curtain -19°C

-20°C

8°C

Booster

Booster

Low Temperature Refrigeration Cooling capacity Dimensions

Weight Compressor

Nom. Unit

REFRIGERATION

2°C

LCBKQ3AV19 Height Width Depth

kW mm mm mm kg

Unit Type Piston displacement m³/h Number of revolutions rpm Output W Starting method Frequency ON/OFF Fan Type Air flow rate Cooling Nom. m³/min Operation range Evaporator Cooling Min.~Max. °CDB Ambient temperature Min.~Max. °C Refrigerant Type / GWP Control Refrigerant oil Type Charged volume l Piping connections Piping length System Booster unit - IU Power supply Phase/Frequency/Voltage Hz/V Trade Price

3.35 480 680 310 47 Hermetically sealed swing compressor 10.16 6,540 1,300 Direct on line (inverter driven) Less than 6 times/hour Propeller fan 1.6 -45~-20 -15~43 R-410A / 2,087.5 Electronic expansion valve Daphne FVC50K + FVC68D 0.85 / 0.5 30m or less 1~/50/220-240 £2,773.00

(1) Evaporating temp. -35°C; outdoor temp. 32°C; suction SH 10K; saturated temp. to discharge pressure of booster unit -10°C (2) Its functioning relies on fluorinated greenhouse gases

Price List 2015

143


LREQ-BY1

ZEAS condensing units When you select a refrigeration condensing unit, you want premium performance with simple installation and maintenance. That’s why you should specify Daikin ZEAS condensing units.

A complete solution for refrigeration applications Compact yet powerful and extremely energy efficient, Daikin ZEAS condensing units offer an industry-leading solution for all kinds of installation projects. ZEAS is an adaptable and controllable solution for all kinds of environments with fluctuating loads such as supermarkets, hotels, restaurants, hospitals and florists, as well as food production facilities such as cold storage, and blast coolers and freezers. Delivering all the benefits of inverter controlled VRV technology for commercial refrigeration systems, ZEAS offers a comprehensive product range suitable for low temperature applications of 5.4 to 15.1 kW at -35/+32°C and medium temperature applications of 12.2 to 37.0 kW at -10°C /+32°C. Its small footprint and low sound levels offer installation flexibility, so you can gain larger capacities even in small spaces. What’s more, the ZEAS solution comes fully packaged and

REFRIGERATION

Outdoor unit Cooling capacity* Dimensions Weight Heat exchanger Fan

Fan motor Compressor

Operation range Refrigerant

Refrigerant oil Piping connections Power supply Voltage range Current Current - 50Hz

kW mm kg

H xW x D

Cooling

Nom.

m³/min kW

m³/h rpm kW Min.~Max. Min.~Max.

°CDB °C kg

l 50m or less 50~130m

Gas Phase/Frequency/Voltage Min. Max. Nominal running Compressor Cooling current (RLA) - 50Hz

Hz/V % % A

Starting current (MSC) Minimum Ssc value Minimum circuit amps (MCA) Maximum fuse amps (MFA) Total overcurrent amps (TOCA) Full load amps (FLA) Fan motor

A kVa A A A A

Trade Price

Residential, Commercial and Industrial

ZEAS condensing units offer: > Compact 2P system with reduced piping lengths > Higher refrigeration capacity to power consumption ratio compared with standard systems > COP of up to 3.0 > Utilises energy efficient R-410A refrigerant LREQ6BY1

12.5 15.2 1,680x635x765 166

LREQ8BY1

LREQ10BY1

LREQ12BY1

19.8

23.8 1,680x930x765 242 Cross fin coil Propeller fan

26.5

102

1 171

13.7

74 655 19.3

LREQ15BY1

LREQ20BY1

33.9 37.9 1,680x1,240x765 331 337

2 179 191 230 240 0.35 0.75 0.35 + 0.35 0.75+0.75 Direct drive Hermetically sealed scroll compressor Hermetically sealed scroll compressor (x2) 11.18 13.85 19.68 23.36 25.27 32.24 35.8 5,280 6,540 4,320+2,900 6,060+2,900 6,960+2,900 5,280+2,900+2,900 6,960+2,900+2,900 2.6 3.2 2.1 + 3.6 3.0 + 3.6 3.4 + 3.6 2.6 + 3.6 + 3.6 3.4 + 3.6 + 3.6 Direct on line (inverter driven) Direct on line (inverter driven) (x2) -45~10 -20~43 R-410A 5.2 7.9 11.5 Electronic expansion valve Daphne FVC68D 1.7 / 2.5 1.7 / 2.5 1.7 / 2.1 / 3.0 1.7 / 2.1 / 3.0 1.7 / 2.1 / 3.0 1.7 / 2.1 / 4.0 1.7 / 2.1 / 4.0 ø 9.5 C1220T (Brazing connection) ø 12.7 C1220T (Brazing connection) ø 9.5 C1220T (Brazing connection) ø 12.7 C1220T (Brazing connection) ø 22.2 C1220T (Brazing connection) ø 28.6 C1220T (Brazing connection) ø 34.9 C1220T (Brazing connection) 3~/50/380-415 -10 10 7.1 9.2 5.3 + 7.5 7.4 + 7.9 9.8 + 8.3 7.0 + 8.2 + 8.2 9.5 + 8.4 + 8.4 95

12.8 15 15.6 0.4 £7,105.00

*Operation conditions of outdoor unit: Te = -10°C, outdoor temperature +32°C, suction SH10°C

144

All in all, it’s a quality solution that delivers maximum refrigeration capacity with minimal fuss.

> Energy efficient inverter control minimises CO2 emissions

LREQ5BY1 Nom. Unit Unit Type Type Quantity Air flow rate Output Drive Type Piston displacement Speed Output Starting method Evaporator Ambient temp. Type Charge Control Type Charged volume Liquid

programmed, with minimal pipe work required, so installation time and cost is reduced. Plus you can depend on Daikin’s dedicated after-sales support to help ensure that commissioning and maintenance go without a hitch.

£8,029.00

£8,855.00

75

84

899 22.0 25 31.5 0.9

1,097 24.0

£10,085.00

£11,570.00

761 31.4

945 35.0 40 48.3

0.4 + 0.4

0.7 + 0.7

£15,259.00

£17,322.00


LREQ-BY1

Multi-ZEAS condensing units The Multi-ZEAS units, deliver the higher capacities required for larger supermarkets, food storage and processing plants, while reducing energy consumption by 35%, compared with traditional refrigeration systems.

Multi-ZEAS provides a superior solution to the traditional rack systems typically used for bigger capacities, because the units can be connected easily – in master and slave combination – so installation piping is reduced and installation time is much quicker. The new high capacity Multi-ZEAS consists of two 15HP units or two 20HP units. This system offers the perfect solution for multiple refrigeration needs in supermarkets and for applications with fluctuating loads and high energy efficiency requirements, such as blast coolers and freezers, cold storage, food outlets and restaurants.

Outdoor unit

Power input Dimensions Weight Heat exchanger Compressor

Fan

Fan motor

Medium temperature Low temperature Medium temperature Low temperature Unit H xW x D Unit Type Type Piston displacement Speed Output Starting method Type Quantity Air flow rate Cooling Output Drive

Nom. Nom. Nom. Nom.

Trade Price

Starting current (MSC)

LREQ40BY1 LREQ20BY1R x 2 75.8 29.6 34.0 27.6 (1,680x1,240x765) x 2 337 x 2

Cross fin coil Hermetically sealed scroll compressor m³/h rpm W

32.24 x 2 (5,280+2,900+2,900) x 2 (2.6+3.6+3.6) x 2

35.80 x 2 (6,960+2,900+2,900) x 2 Direct online (inverter driven) Propeller fan

Nom.

Sound pressure level Nom. Operation range Evaporator Cooling Min.~Max. Ambient temperature Min.~Max. Refrigerant Type Charge Control Refrigerant oil Type Charged volume Piping Liquid 50m or less connections 50~130m Gas 50m or less 50~130m Power supply Phase/Frequency/Voltage Current Nominal running current (RLA) - 50Hz Current - 50Hz

kW kW kW kW mm kg

LREQ30BY1 LREQ15BY1R x 2 67.8 27.8 30.4 25.6 (1,680x1,240x765) x 2 331 x 2

m³/min W

2x2 230 x 2 (350 x 2) x 2

2x2 240 x 2 (750 x 2) x 2

REFRIGERATION

System Refrigerating capacity

ZEAS condensing units are far quieter than traditional units, because inverter control keeps fan speeds low while still meeting cooling demand. At night maximum fan speeds can be lowered to reduce noise, with only a limited loss of refrigeration capacity. The ‘plug and play’ units come fully equipped and do not need to be installed in a plant room, so retail space is maximised. All ZEAS units have optimised controls, which can communicate with a third party monitoring system or building management system via Daikin’s powerful Modbus interface. Servicing and maintenance is also simple.

Direct drive dBA °CDB °C

65.0

66.0 -45~10 -20~43 R-410A 11.5 x 2 Electronic expansion valve Daphne FVC68D (1.7+ 2.1+2.1+ 4.0) x 2

kg

l

ø 19.05 C1220T (Brazing connection) ø 41.28 C1220T (Brazing connection) Hz/V A A

3~/50/380~415 (7.0/8.2/8.2) x 2

(9.5/8.4/8.4) x 2

109

115

£30,290.00

£34,416.00

Price List 2015

145


REFRIGERATION


Daikin UK Price List 2015

Applied Daikin Chillers 148 149

Chilled Water Fan Coils

152

APPLIED

Water Chillers

Scotland Region 0845 641 9330

Northern Region 0845 641 9340

Midlands Region 0845 641 9370

Western Region 0845 641 9320

North London 0845 641 9360

South London 0845 641 9355


Daikin Chillers

Whatever your needs in climate control or process chilling, there is a system that has proved its value in many situations – from factories and warehouses to hotels and department stores,

APPLIED

from residential applications to district cooling.

Daikin’s ranges of air-cooled and water-cooled chillers are designed to suit every application – large or small – offering the ultimate in flexibility and control. The unique combination of advanced technology, experience and reliability make Daikin chillers the ideal choice.

Highest efficiency

Daikin chillers have nominal cooling capacities of 5kW to 2,000kW (air-cooled) or 13kW to 2,156kW (water-cooled).

> Lowest total cost of ownership

Worldwide experience A global leader in HVAC solutions, Daikin has the world’s most advanced facilities for air conditioning research and development: the Applied Development Center, Minneapolis, Minnesota. > I n-house manufacture of main chiller components (compressors, fans, condenser coils, software).

Using the latest technology, Daikin achieves industry-leading efficiency and energy-saving operation for outstanding cost saving performance.

> Fast payback time > Environment-friendly solutions

Quality, reliability > Zero defect policy ensures quality of components and finished products > All chillers factory run and subjected to quality audit before shipment > Eurovent and AHRI certification

148

Residential, Commercial and Industrial


Air Cooled Water Chillers Model No

Nominal Cooling kW

Nominal Heating kW

Power Supply

Trade Price

Product Overview 2015 – Air Cooled Water Chillers kW

50

100

250

500

750

1000

1250

1500

2000

Air Cooled Inverter Packaged Swing / Scroll Compressor – R410a c/w Hydraulic Pump and Expansion Vessel EWAQ005ADVP EWAQ006ADVP EWAQ007ADVP EWAQ009ACV3P EWAQ010ACV3P EWAQ011ACV3P EWAQ009ACW1P EWAQ011ACW1P EWAQ013ACW1P

5.20 6.00 7.10 8.60 9.60 11.10 9.10 11.10 13.30

-

1-phase 1-phase 1-phase 1-phase 1-phase 1-phase 3-phase 3-phase 3-phase

£2,061.00 £2,259.00 £2,503.00 £2,856.00 £3,023.00 £3,249.00 £2,980.00 £3,276.00 £3,471.00

Air Cooled Inverter Packaged Scroll Compressor – R410a EWAQ016BAWN EWAQ021BAWN EWAQ025BAWN EWAQ032BAWN EWAQ040BAWN EWAQ050BAWN EWAQ064BAWN

17.4 21.7 25.8 32.3 43.4 51.8 64.5

-

3-phase 3-phase 3-phase 3-phase 3-phase 3-phase 3-phase

£4,714.00 £5,550.00 £6,260.00 £7,223.00 £9,552.00 £10,643.00 £12,290.00

Notes:

Fitted Options:

i) Please contact your local sales office for further information on these products – Download information from www.daikin.co.uk ii) Nominal cooling capacities are based on 35°C ambient, chilled water @ 12/7°C

To Fit Model EWAQ-A

EWAQ-ADVP

EWAQ-ACV3P

EWAQ-ACW1P

Part No

Description

005

006

007

009

010

011

009

011

013

OP10

Evaporator Heater Tape

£276

£276

£276

£304

£304

£304

£304

£304

£304

iii) EWAQ -A series only operates in cooling down to ambients of +10°C

To Fit Model EWAQ-BA

iv) The EWAQ064BA delivery does not include offloading to kerbside. Additional costs for delivery with a Hi-ab are available on request

Part No

Description

016

021

025

032

040

050

064

UK57-BA UK08B-BA UK78-BA UK79-BA

Evaporator Heater Tape Chilled Water Down to -10 Low Lift Pump High Lift Pump

£394 £292 £438 £642

£394 £292 £438 £642

£394 £292 £438 £642

£394 £292 £584 £642

£496 £394 £584 £875

£496 £394 £584 £875

£496 £394 £584 £875

Air Cooled Heat Pump Water Chillers Model No

Nominal Cooling kW

Nominal Heating kW

Power Supply

Trade Price

Product Overview 2015 – Air Cooled Heat Pump Water Chillers kW

0

50

100

200

300

400

500

600

Air Cooled Heat Pump Inverter Packaged Swing / Scroll Compressor – R410a c/w Hydraulic Pump and Expansion Vessel EWYQ005ADVP EWYQ006ADVP EWYQ007ADVP EWYQ009ACV3P EWYQ010ACV3P EWYQ011ACV3P EWYQ009ACW1P EWYQ011ACW1P EWYQ013ACW1P

5.20 6.00 7.10 8.60 9.60 11.10 9.10 11.10 13.30

5.65 6.35 7.75 9.90 11.40 12.90 10.90 12.40 13.90

1-phase 1-phase 1-phase 1-phase 1-phase 1-phase 3-phase 3-phase 3-phase

£2,380.00 £2,571.00 £2,845.00 £3,288.00 £3,415.00 £3,460.00 £3,415.00 £3,706.00 £3,917.00

Air Cooled Heat Pump Inverter Packaged Scroll Compressor – R410a 17.4 21.7 25.8 32.3 43.4 51.8 64.5

16.2 20.3 24.6 30.7 40.6 49.0 61.5

3-phase 3-phase 3-phase 3-phase 3-phase 3-phase 3-phase

£5,421.00 £6,385.00 £7,202.00 £8,305.00 £10,985.00 £12,237.00 £14,135.00

APPLIED

EWYQ016BAWN EWYQ021BAWN EWYQ025BAWN EWYQ032BAWN EWYQ040BAWN EWYQ050BAWN EWYQ064BAWN

Notes:

Fitted Options:

i) Please contact your local sales office for further information on these products – Download information from www.daikin.co.uk

To Fit Model EWYQ-A Part No Description OP10 Evaporator Heater Tape

ii) Nominal cooling capacities are based on 35°C ambient, chilled water @ 12/7°C iii) Nominal heating capacities are based on 7°C db / 6°C wb ambient, water @ 45 / 50°C iv) EWYQ -A series only operates in cooling down to ambients of +10°C v) The EWYQ064BA delivery does not include offloading to kerbside. Additional costs for delivery with a Hi-ab are available on request

EWYQ-ADVP 005 006 007 £276 £276 £276

EWYQ-ACV3P 009 010 011 £304 £304 £304

EWYQ-ACW1P 009 011 013 £304 £304 £304

016 £394 £292 £438 £642

032 £394 £292 £584 £642

064 £496 £394 £584 £875

To Fit Model EWYQ-BA Part No

Description

UK57-BA UK08B-BA UK78-BA UK79-BA

Evaporator Heater Tape Chilled Water Down to -10 Low Lift Pump High Lift Pump

021 £394 £292 £438 £642

025 £394 £292 £438 £642

040 £496 £394 £584 £875

050 £496 £394 £584 £875

Price List 2015

149


Water Cooled Chillers Model No

Nominal Cooling kW

Nominal Heating kW

Power Supply

Trade Price

Product Overview 2015 – Water Cooled Chillers kW

50

100

250

500

750

1000

1250

1500

2000

Water Cooled Packaged Scroll Compressor – R407C EWWP014KBW1N EWWP022KBW1N EWWP028KBW1N EWWP035KBW1N EWWP045KBW1N EWWP055KBW1N EWWP065KBW1N

12.90 21.40 27.80 32.30 42.80 55.70 64.70

-

3-phase 3-phase 3-phase 3-phase 3-phase 3-phase 3-phase

£2,909.00 £3,439.00 £3,951.00 £4,598.00 £5,664.00 £6,326.00 £7,065.00

Notes: i) Please contact your local sales office for further information on these products – Download information from www.daikin.co.uk ii) Nominal cooling capacities are based on chilled water @ 12/7°C, condenser water @ 30/35°C

Fitted Options: To Fit Model EWWP-KAW1N Part No

Description

014

022

028

035

045

055

065

OPZH OPZL

Chilled Water Down to -5 Chilled Water Down to -10

£167 £167

£167 £167

£167 £167

£167 £167

£167 £167

£167 £167

£167 £167

Condenserless Chillers Model No

Nominal Cooling kW

Nominal Heating kW

Power Supply

Trade Price

Product Overview 2015 – Condenserless Chillers kW

50

100

250

500

750

1000

1250

Condenserless Packaged Scroll Compressor – R407C EWLP012KBW1N EWLP020KBW1N EWLP026KBW1N EWLP030KBW1N EWLP040KBW1N EWLP055KBW1N EWLP065KBW1N

12.10 20.00 26.80 31.20 40.00 53.70 62.40

-

3-phase 3-phase 3-phase 3-phase 3-phase 3-phase 3-phase

POA POA POA POA POA POA POA

Notes: i) Please contact your local sales office for further information on these products – Download information from www.daikin.co.uk

APPLIED

ii) Nominal cooling capacities are based on chilled water @ 12/7°C, condensing temperature @ 45°C, liquid temperature @40°C

Fitted Options: To Fit Model EWLP-KAW1N

150

Residential, Commercial and Industrial

Part No

Description

012

020

026

030

040

055

065

OPZH OPZL

Chilled Water Down to -5 Chilled Water Down to -10

POA POA

POA POA

POA POA

POA POA

POA POA

POA POA

POA POA

1500


Applied Systems Kit Options Loose Accessory Options: Description

Trade Price

External control adaptor Low noise & demand limit - EWAQ/EWYQ-BA HYDRAULIC MODULE -Normal static + anti-freeze protection - EWWP014~022/EWLP012~020 HYDRAULIC MODULE-High static + anti-freeze protection - EWWP014~022/EWLP012~020 HYDRAULIC MODULE-Normal static + anti-freeze protection - EWWP028~035/EWLP026~030 HYDRAULIC MODULE-High static + anti-freeze protection - EWWP028~035/EWLP026~030 HYDRAULIC MODULE-Normal static + anti-freeze protection - EWWP045~065/EWLP040~065 HYDRAULIC MODULE-High static + anti-freeze protection - EWWP045~065/EWLP040~065 Address card for connection to BMS - EWWP, EWLP (note not available on the modular EWWP) Remote Control - EWWP, EWLP (needs EKAC10C) Buffertank 200I Low noise operation EWLP012~EWWP14 Low noise operation EWLP02~030, EWWP22-35 Low noise operation EWLP040~065, EWWP45-65 Digital I/O PCB - EWAQ / EWYQ - AC Demand PCB / Inputs - EWAQ/EWYQ-BA (2 x on size 40/50/64) Remote user interface (in parallel) - EWAQ/EWYQ-BA MODBUS Interface - EWAQ/EWYQ-BA Sequence Controller - EWAQ/EWYQ-BA

£221.00 £1,668.00 £1,775.00 £1,775.00 £1,848.00 £1,991.00 £1,991.00 £86.00 £163.00 £1,097.00 £155.00 £155.00 £310.00 £104.00 £104.00 £157.00 £205.00 £640.00

APPLIED

Model DTA104A62 EHMC10A10 EHMC10A80 EHMC15A10 EHMC15A80 EHMC30A10 EHMC30A80 EKAC10C EKRUMCA EKBT EKLS1 EKLS2 EKLS2 X 2 EKRP1HBA EKRP1AHT EKRUAHTB RTD-W EKCC-W

Price List 2015

151


Product Overview

Fan Coil Units

Fan Coil Units are a highly efficient means of turning a water chiller, heat pump or hot water boiler into an efficient, quiet air conditioning system. These units are an effective solution to provide a comfortable environment for both commercial and residential applications. Daikin offers a wide range of Fan Coil Units for both concealed and exposed applications. Cassette, cased low wall, cased high wall & ducted models are available to suit particular installation requirements. Many of these are available with Brushless Direct Current (BLDC) Fan Motors providing high energy APPLIED

efficiency and comfort levels. The only moving part in the units is the fan, making them ideal for use in offices, hotels and at home. The goal is to obtain the right solution, both technically and aesthetically.

152

Residential, Commercial and Industrial


Product Overview

Type

Ceiling mounted cassette

Floor standing unit

Flexi type unit

Wall mounted unit

Concealed ceiling unit

Model

Product name

Fan motor type

Capacity

Round flow cassette - 900 x 900 cassette - 360° air discharge ensures uniform air flow - Integrated fresh air intake - Easy installation in corners - Standard drain pump with 850 mm lift

FWC-BT/BF

BLDC

Cooling: 5.8 - 8.7 kW Heating: 7.5 - 12.1 kW

4-way blow ceiling mounted cassette - 600 x 600 cassette - Integrated fresh air intake - Horizontal auto swing - Easy installation in corners - Standard drain pump with 750 mm lift

FWF-BT/BF

AC

Cooling: 2.0 - 5.2 kW Heating: 2.9 - 6.7 kW

Floor standing unit - For vertical mounting - Continuous air flow regulation and fan speed modulation - Up to 70% energy savings - Low sound levels

FWZ-AT/AF

BLDC

Cooling: 2.64 - 10.08 kW Heating: 2.46 - 11.18 kW

Floor standing unit - For vertical mounting - Insulated valve packages, no extra drain pan required - Fast-on connections for electrical options: no tools needed - Easy maintenance

FWV-DAT/DAF

AC

Cooling: 1.46 -8.02 kW Heating: 1.90 - 10.03 kW

Flexi type unit - For horizontal or vertical mouting - Continuous air flow regulation and fan speed modulation - Up to 70% energy savings - Low sound levels

FWR-AT/AF

BLDC

Cooling: 2.64 - 10.08 kW Heating: 2.46- 11.18 kW

Flexi type unit - For horizontal or vertical mounting - Insulated valve packages, no extra drain pan required - Fast-on connections for electrical options: no tools needed - Easy maintenance

FWL-DAT/DAF

AC

Cooling: 1.46 - 8.02 kW Heating: 1.90 - 10.03 kW

Concealed flexi type unit - For horizontal or vertical concealed mounting - Continuous air flow regulation and fan speed modulation - Up to 70% energy savings - Low sound levels

FWS-AT/AF

BLDC

Cooling: 2.64 - 10.08 kW Heating: 2.46 - 11.18 kW

Concealed flexi type unit - For horizontal or vertical concealed mounting - Insulated valve packages, no extra drain pan required - Fast-on connections for electrical options: no tools needed - Easy maintenance

FWM-DAT/DAF

AC

Cooling: 1.46 -8.02 kW Heating: 1.90 - 10.03 kW

Wall mounted unit - High aesthetic cabinet design - Optimum air distribution - Easy installation - 3-speed fan motor

FWT-CT

AC

Cooling: 2.43 - 5.28 kW Heating: 3.22 - 7.33 kW

Concealed ceiling unit with medium ESP - For horizontal concealed mounting - Instant adjustment to temperature and relative humidity changes - Available static pressure up to 80 Pa - Low sound levels

FWP-AT

BLDC

Cooling: 2.61 - 6.47 kW Heating: 5.47 - 12.28 kW

Concealed ceiling unit with medium ESP - For horizontal concealed mounting - Available static pressure up to 80 Pa - 7-speed electrical motors (thermal protection on windings) - Easy maintenance

FWB-BT

AC

Cooling: 2.61 - 10.34 kW Heating: 5.47 - 18.78 kW

Concealed ceiling unit with high ESP - For horizontal or vertical concealed mounting - Available static pressure up to 120 Pa - Easy maintenance

FWD-AT/AF

AC

Cooling: 3.90 - 18.30 kW Heating: 4.05 - 21.92 kW

APPLIED

Fan Coil Units

Please contact your local sales office for further information on these products – Download information from www.daikin.co.uk

Capacity conditions EUROVENT conditions

TYPICAL UK cooling conditions

Cooling 27°C db / 19°C wb - Entering water 7°C - Leaving water 12°C Heating 4 Pipe 20°C db - Entering water 70°C - Leaving water 60°C Heating 2 Pipe 20°C db - Entering water 50°C - Flow rate as in cooling mode

22°C db / 16.0°C wb - Entering water 7°C - Leaving water 12°C 0 Pa External Static Pressure 0% Glycol FWP & FWD Ducted FCU - Above capacities are based on 30 Pa External Static Pressure FWS Uncased - Based on 20 pa external static

Price List 2015

153


New BLDC (Brushless Direct Current)

Inverter Driven Floor Standing Fan Coil Units Cased Low Wall Mount Type 2-pipe Capacity

Dimensions

Weight Sound Power Sound Pressure Air Flow Rate Water Connections Electrical Data

UK Total Cooling Nominal Cooling Nominal Heating Height Width Depth High/Low High/Low High

kW kW kW mm mm mm kg dBA dBA m3/min inch

Weight Sound Power Sound Pressure Air Flow Rate Water Connections Electrical Data

FWZ06ATN

FWZ08ATN

2.57 4.96 6.4 226 987 564 25 70/28 62/20 15 1/2

3.23 6.32 7.51 226 1194 564 31 64/28 56/20 20 1/2

5.11 10.08 11.18 251 1404 564 41 71/28 63/20 27.66 3/4

1ph

Cased Low Wall Mount Type 4-pipe

Dimensions

FWZ03ATN

1.39 2.64 3.47 226 774 564 20 62/28 54/20 9.33 1/2

Power Supply

Trade Fan Coil Price

Capacity

FWZ02ATN

UK Total Cooling Nominal Cooling Nominal Heating Height Width Depth High/Low High/Low High

kW kW kW mm mm mm kg dBA dBA m3/min inch

£267.00

£283.00

£327.00

£407.00

FWZ02AFN

FWZ03AFN

FWZ06AFN

FWZ08AFN

1.39 2.64 2.46 226 774 564 21 62/28 54/20 9.33 1/2

2.57 4.96 4.19 226 987 564 26 70/28 62/20 15 1/2

3.23 6.32 6.45 226 1194 564 33 64/28 56/20 20 1/2

5.11 10.08 10.06 251 1404 564 44 71/28 63/20 27.66 3/4

£303.00

£366.00

£442.00

FWR02ATN

FWR03ATN

FWR06ATN

FWR08ATN

1.39 2.64 3.47 226 774 564 21 62/28 54/20 9.33 1/2

2.57 4.96 6.4 226 987 564 27 70/28 62/20 15 1/2

3.23 6.32 7.51 226 1194 564 33 64/28 56/20 20 1/2

5.11 10.08 11.18 251 1404 564 44 71/28 63/20 27.66 3/4

Power Supply

1ph

Trade Fan Coil Price

£291.00

New BLDC (Brushless Direct Current)

Inverter Driven Flexi Fan Coil Units Cased Flexi Type 2-pipe Capacity

Dimensions

Weight Sound Power Sound Pressure Air Flow Rate Water Connections Electrical Data

UK Total Cooling Nominal Cooling Nominal Heating Height Width Depth High/Low High/Low High

kW kW kW mm mm mm kg dBA dBA m3/min inch

Power Supply

1ph

Trade Fan Coil Price

APPLIED

Cased Flexi Type 4-pipe Capacity

Dimensions

Weight Sound Power Sound Pressure Air Flow Rate Water Connections Electrical Data

UK Total Cooling Nominal Cooling Nominal Heating Height Width Depth High/Low High/Low High

kW kW kW mm mm mm kg dBA dBA m3/min inch

£301.00

£349.00

£445.00

FWR02AFN

FWR03AFN

FWR06AFN

FWR08AFN

1.39 2.64 2.46 226 774 564 22 62/28 54/20 9.33 1/2

2.57 4.96 4.19 226 987 564 28 70/28 62/20 15 1/2

3.23 6.32 6.45 226 1194 564 35 64/28 56/20 20 1/2

5.11 10.08 10.06 251 1404 564 46 71/28 63/20 27.66 3/4

£388.00

£492.00

Power Supply

Trade Fan Coil Price

154

£280.00

Residential, Commercial and Industrial

1ph £305.00

£329.00


New BLDC (Brushless Direct Current)

Inverter Driven Low Static Concealed Flexi Fan Coil Units Concealed Flexi Type 2-pipe Capacity

Dimensions

Weight Sound Power Sound Pressure Air Flow Rate Water Connections Electrical Data

UK Total Cooling Nominal Cooling Nominal Heating Height Width Depth High/Low High/Low High

Weight Sound Power Sound Pressure Air Flow Rate Water Connections Electrical Data

FWS06ATN

FWS08ATN

2.02 4.96 6.4 224 794 535 19 70/28 62/20 15 1/2

2.52 6.32 7.51 224 1004 535 23 64/28 56/20 20 1/2

3.99 10.08 11.18 249 1214 535 32 71/28 63/20 27.66 3/4

1ph

Concealed Flexi Type 4-pipe

Dimensions

FWS03ATN

1.08 2.64 3.47 224 584 535 15 62/28 54/20 9.33 1/2

Power Supply

Trade Fan Coil Price

Capacity

FWS02ATN kW kW kW mm mm mm kg dBA dBA m3/min inch

UK Total Cooling Nominal Cooling Nominal Heating Height Width Depth High/Low High/Low High

£239.00

£257.00

£293.00

£366.00

FWS02AFN

FWS03AFN

FWS06AFN

FWS08AFN

1.08 2.64 2.46 224 584 535 16 62/28 54/20 9.33 1/2

2.02 4.96 4.19 224 794 535 20 70/28 62/20 15 1/2

2.52 6.32 6.45 224 1004 535 25 64/28 56/20 20 1/2

3.99 10.08 10.06 249 1214 535 34 71/28 63/20 27.66 3/4

£329.00

£412.00

kW kW kW mm mm mm kg dBA dBA m3/min inch

Power Supply

1ph

Trade Fan Coil Price

£265.00

£287.00

Floor Standing and Flexi Fan Coil Unit Accessories FWZ, FWR, FWS 2-pipe 3-way valve kits c/w lockshields 4-pipe 3-way valve kits c/w lockshields Vertical drainpan Horizontal drainpan Advanced Plus Electronic Controller On board installation kit (FWZ & FWR - Low Wall Mounted Only) Return Air Sensor

Notes: 02-03

06

08

E2MV03A6 £121.00 E4MV03A6 £217.00

E2MV06A6 £121.00 E4MV06A6 £217.00 EDPVB6 £3.00 EDPHB6 £3.00 FWEC3A £114.00 FWECKA £11.00 FWTSKA £8.00

E2MV10A6 £128.00 E4MV10A6 £227.00

i) Each controller version includes the water probe ii) The on board installation kit includes a remote air probe (if installed the internal fan coil robe is disabled) iii) The FWEC3A can operate up to 247 fan coils as master slave control, plus weekly schedule timer, proportional valve control and 2 digital outputs (1 per fan coil required).

APPLIED

Loose Accessory Options:

Price List 2015

155


New BLDC (Brushless Direct Current)

Inverter Driven Medium Static Ducted Fan Coil Units Concealed Ducted Type 2-pipe Capacity

Dimensions

Weight Sound Power Sound Pressure Air Flow Rate Water Connections Electrical Data

UK Total Cooling Nominal Cooling Nominal Heating Height Width Depth High/Low High/Low High

kW kW kW mm mm mm kg dBA dBA m3/min inch

FWP02AT

FWP03AT

FWP04AT

FWP05AT

FWP06AT

FWP07AT

1.34 2.61 5.47 239 1039 609 24 56/40 44/24 6.66 3/4

1.67 3.14 6.01 239 1039 609 26 56/40 44/24 6.66 3/4

2.03 3.49 6.47 239 1039 609 28 56/40 44/24 6.66 3/4

2.5 5.08 10.31 239 1389 609 33 61/39 50/27 13.33 3/4

2.77 5.45 11.39 239 1389 609 35 61/39 50/27 13.33 3/4

3.47 6.47 12.28 239 1389 609 38 61/39 50/27 13.33 3/4

Power Supply

1ph

Trade Fan Coil Price - Naked - No Valve

FWP02ATN

FWP03ATN

FWP04ATN

FWP05ATN

FWP06ATN

FWP07ATN

Trade Fan Coil Price- Complet with 3 - way valve fitted

£344.00 FWP02ATV

£359.00 FWP03ATV

£373.00 FWP04ATV

£438.00 FWP05ATV

£443.00 FWP06ATV

£472.00 FWP07ATV

£422.00

£436.00

£450.00

£514.00

£519.00

£549.00

Please note if you require a 4 pipe fan coil please purchase additional heat exhanger as shown below

Loose Accessory Options: FWP Additional Heat exchanger (4 Pipe) nominal heating cap 3.2kW Additional Heat exchanger (4 Pipe) nominal heating cap 6.1kW 2-way valve cooling coil 3-way valve add.h/e 2-way valve add.h/e Advanced Plus Electronic Controller

APPLIED

Return Air Sensor

156

Residential, Commercial and Industrial

Notes: 02 - 04

05 - 07

EAH04A6 £89.00 -

EAH07A6 £103.00 E2MV207A6 £51.00 E2MV307A6 £91.00 E2MV207A6 £51.00 FWEC3A £114.00 FWTSKA £8.00

i) Each controller version includes the water probe ii) The FWEC3A can operate up to 247 fan coils as master slave control, plus weekly schedule timer, proportional valve control and 2 digital outputs (1 per fan coil required).


AC Fan Motor - 3 speed

High Static Ducted Fan Coil Units Concealed Ducted Type 2-pipe

Dimensions

Weight Sound Power Sound Pressure Air Flow Rate Water Connections Electrical Data

UK Total Cooling Nominal Cooling Nominal Heating Height Width Depth High / Low High / Low High

kW kW kW mm mm mm kg dBA dBA m3/min inch

Concealed Ducted Type 4-pipe

Dimensions

Weight Sound Power Sound Pressure Air Flow Rate Water Connections Electrical Data

FWD06AT

FWD08AT

FWD10AT

FWD12AT

FWD16AT

FWD18AT

2.15 3.9 4.05 280 754 559 33 66/54 56/46 13.33 3/4

3.48 6.2 7.71 280 964 559 41 69/59 61/51 20.83 3/4

4.44 7.8 9.43 280 1174 559 47 72/62 64/54 26.67 3/4

4.92 8.82 10.79 280 1174 559 49 72/62 64/54 26.67 3/4 1ph

7.21 11.9 14.45 352 1174 718 65 74/60 66/52 36.67 1

8.96 16.4 19.81 352 1384 718 77 78/69 70/61 50 1

9.91 18.3 21.92 352 1384 718 80 78/69 70/61 50 1

£270.00

£355.00

£415.00

£462.00

£574.00

£735.00

£808.00

FWD04AF

FWD06AF

FWD08AF

FWD10AF

FWD12AF

FWD16AF

FWD18AF

2.15 3.9 4.05 280 754 559 35 66/54 56/46 13.33 3/4

3.48 6.2 7.71 280 964 559 43 69/59 61/51 20.83 3/4

4.44 7.8 9.43 280 1174 559 50 72/62 64/54 26.67 3/4

4.92 8.82 10.79 280 1174 559 52 72/62 64/54 26.67 3/4 1ph

7.21 11.9 14.45 352 1174 718 71 74/60 66/52 36.67 1

8.96 16.4 19.81 352 1384 718 83 78/69 70/61 50 1

9.91 18.3 21.92 352 1384 718 86 78/69 70/61 50 1

£316.00

£413.00

£482.00

£545.00

£672.00

£853.00

£935.00

Power Supply

Trade Fan Coil Price

Capacity

FWD04AT

UK Total Cooling Nominal Cooling Nominal Heating Height Width Depth High / Low High / Low High

kW kW kW mm mm mm kg dBA dBA m3/min inch

Power Supply

Trade Fan Coil Price

Loose Accessory Options: FWD 2-pipe 3-way valve 4-pipe 3-way valve Vertical Drain pan Horizontal Drain Pan Master slave interface Power interface (S) Standard Electronic Controller Advanced Electronic Controller Advanced Plus Electronic Controller Return Air Sensor

Notes: 4 ED2MV04A6 £128.00 ED4MV04A6 £244.00

6

8 -10

ED2MV10A6 £128.00 ED4MV10A6 £244.00 EDDPV10A6 £11.00 EDDPH10A6 £13.00 EPIMSA6 £84.00 EPIB6 £84.00 FWEC1A £65.00 FWEC2A £82.00 FWEC3A £114.00 FWTSKA £8.00

12

16 -18

ED2MV12A6 ED2MV18A6 £128.00 £133.00 2x ED2MV12A6 2 x ED2MV18A6 £256.00 £266.00 EDDPV18A6 £11.00 EDDPH18A6 £13.00 -

F WEC1A is designed as an individual unit controller. Power interface EPIB6 is required for unit size 16 and 18 can operate up to 4 fan coils by adding a EPIMSA6. If using this controller to operate up to 4 fan coil units by adding a EPIMSA6 you will require a EPIB6 power interface for unit size 12,16,18. FWEC2A can operate up to 247 fan coils as master slave control ( 1 per fan coil required). Power interface EPIB6 is required for each unit size 16 and 18. FWEC3A can operate up to 247 fan coils as master slave control, plus weekly schedule timer, proportional valve control (by others) and 2 digital outputs ( 1 per fan coil required). Please note that: i) Each controller version includes the water probe.

APPLIED

Capacity

Price List 2015

157


AC Fan Motor - 3 speed

600 Sq Cassette Fan Coil Units 600sq Cassette Type 2-pipe c/w Decoration Panel BYFQ60B3 Capacity

Dimensions

Weight Sound Power Sound Pressure Air Flow Rate Water Connections Electrical Data

UK Total Cooling Nominal Cooling Nominal Heating Height Width Depth High / Low High / Low High

kW kW kW mm mm mm kg dBA dBA m3/min inch

600sq Cassette Type 4-pipe c/w Decoration Panel BYFQ60B3

Dimensions

Weight Sound Power Sound Pressure Air Flow Rate Water Connections Electrical Data

FWF03BT

FWF04BT

FWF05BT

1.20 2 2.9 260 575 575 19 44/36 31/26 7.9

1.9 3.2 4 260 575 575 19 44/36 31/26 7.9

2.5 4.2 5.4 260 575 575 19 50/36 40/26 11.2

3.1 5.2 6.7 260 575 575 19 55/42 45/30 14.9

3/4 “ BSP Female 1 ph

Power Supply

Trade Fan Coil Price

Capacity

FWF02BT

UK Total Cooling Nominal Cooling Nominal Heating Height Width Depth High / Low High / Low High

kW kW kW mm mm mm kg dBA dBA m3/min inch

£509.00

£535.00

£565.00

£603.00

FWF02BF

FWF03BF

FWF04BF

FWF05BF

1.10 2 3.9 260 575 575 19 44/36 31/26 7.9

1.6 2.7 3.8 260 575 575 20 44/36 31/26 7.2

2 3.5 4.9 260 575 575 20 50/36 40/26 10.4

2.5 4.5 6.1 260 575 575 20 55/42 45/30 13.9

3/4 “ BSP Female 1 ph

Power Supply

Trade Fan Coil Price

£541.00

£565.00

£603.00

£637.00

FWC06BT

FWC07BT

FWC08BT

FWC09BT

3.30 5.8 8 288 840 840 26 43/31 29/21 17.7

4.1 6.8 8.9 288 840 840 26 47/33 33/22 20.6

4.3 7.7 10.6 288 840 840 26 53/36 39/24 25.4

4.8 8.7 12.1 288 840 840 26 57/40 43/28 30.8

BLDC Fan Motor - 3 speed

Cassette Fan Coil Units Cassette Type 2-pipe c/w Decoration Panel BYCQ140C Capacity

Dimensions

Weight Sound Power Sound Pressure Air Flow Rate Water Connections Electrical Data

UK Total Cooling Nominal Cooling Nominal Heating Height Width Depth High / Low High / Low High

kW kW kW mm mm mm kg dBA dBA m3/min inch

Trade Fan Coil Price

APPLIED

Cassette Type 4-pipe c/w Decoration Panel BYCQ140C Capacity

Dimensions

Weight Sound Power Sound Pressure Air Flow Rate Water Connections Electrical Data

UK Total Cooling Nominal Cooling Nominal Heating Height Width Depth High / Low High / Low High

kW kW kW mm mm mm kg dBA dBA m3/min inch

£621.00

£637.00

£653.00

£681.00

FWC06BF

FWC07BF

FWC08BF

FWC09BF

3.30 5.8 7.5 288 840 840 29 43/31 29/21 17.1

4 6.6 8.4 288 840 840 29 47/33 33/22 19.9

4.3 7.6 9.7 288 840 840 29 53/36 39/24 24.6

4.8 8.7 11 288 840 840 29 57/40 43/28 29

£691.00

£708.00

3/4 “ BSP Female 1 ph

Power Supply

Trade Fan Coil Price

158

3/4 “ BSP Female 1 ph

Power Supply

Residential, Commercial and Industrial

£649.00

£673.00


Cassette Accessories Loose Accessory Options:

Notes:

FWF/FWC

FWF/FWC

FWC only

FWC only

Remote wired controller

BRC315D £67.00 DCS601C51 £1,641.00 KRP4A53 £67.00 KRP4A53/UK.FB2 £92.00 KRP2A52 £177.00 KRP2A52/UK.FB2 £202.00 EKFCMBCB £55.00 EKMV2C09B £58.00 EKMV3C09B £64.00 EKRP1C11 £100.00

Wireless remote control heat pump

BRC7FA532F £152.00 BRC7F533F £121.00 KRCS01-4 £42.00 KRP1H98 £37.00

Intelligent touch controller Unit/Group adapter pcb Unit/Group adapter pcb complete with installation box System adaptor pcb System adaptor pcb complete with installation box Optional pcb for connection to ModBus (2 stopbit) 2-Way on / off valve kit 3-Way on / off valve kit Valve control PCB

Wireless remote control cooling only Remote air sensor Installation box for an EKRP1C11 valve PCB

FWF only

FWF only

Wireless remote control heat pump

BRC7E530 £121.00 BRC7E531 £121.00 KRCS01-1 £46.00 EKRORO £16.00 KRP1BA101 £43.00

Wireless remote control cooling only Remote air sensor Remote on/off control interface kit Installation box for an EKRP1C11 valve PCB

i) FWF and FWC Cassette Fan Coil prices include decoration panel ii) It is not possible to use Intelligent Touch control for combination with both VRV and water based fan coils FWF-Valve control requirements 2 pipe unit: 1 x valve kit + 1 x installation box for PCB KRP1BA101 + 1 x valve control PCB EKRP1C11 4 pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1BA101 + 1 x valve control PCB EKRP1C11 FWC-Valve control requirements 2 pipe unit: 1 x valve kit + 1 x installation box for PCB KRP1H98 + 1 x valve control PCB EKRP1C11 4 pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1H98 + 1 x valve control PCB EKRP1C11

AC Fan Motor - 3 speed

Wall Mounted Fan Coil Units

Dimensions

Weight Sound Power Sound Pressure Air Flow Rate Water Connections Electrical Data

UK Total Cooling Nominal Cooling Nominal Heating Height Width Depth High / Low High / Low High

kW kW kW mm mm mm kg dBA dBA m3/min inch

FWT02CT

FWT03CT

FWT04CT

FWT05CT

FWT06CT

1.59 2.43 3.22 288 800 206 10 45/36 34/25 7.36 1/2

1.67 2.7 3.52 288 800 206 10 48/39 35/25 7.93 1/2

2.1 3.31 4.4 288 800 206 10 55/45 42/32 10.48 1/2 1ph

2.9 4.54 6.01 310 1065 224 15 55/47 42/34 14.43 1/2

3.41 5.28 7.33 310 1065 224 15 59/51 42/39 17.55 1/2

£196.00

£204.00

£234.00

£283.00

£301.00

Power Supply

Trade Fan Coil Price

Loose Accessory Options: FWT Standard wired remote controller Simplified wired remote controller Wireless controller for heat pump

Notes: FWT MERCA £76.00 SRC-HPA £39.00 WRC-HPC £15.00

i) FWT fan coils are optimised for valveless control in cooling. We would recommend that a valve is fitted if being used for heating only and for more precise control in cooling. ii) We would recommend the field supply of a 240V - 4 port 3 way valve complete with 240V actuator.

Price List 2015

159

APPLIED

Cased High Wall Mount Type 2-pipe Capacity


APPLIED


Daikin UK Price List 2015

Miscellaneous Delivery Information

162

Goods Returns Procedure

163

Field Quality Service (FQS)

164

Daikin Service Tools

165

Training 166

Scotland Region 0845 641 9330

168

Northern Region 0845 641 9340

Midlands Region 0845 641 9370

Western Region 0845 641 9320

North London 0845 641 9360

South London 0845 641 9355

MISCELLANEOUS

Terms & Conditions


Delivery Information Cost

Order processing deadline

Standard Delivery Mon - Fri 8:00 to 17:00 (excluding Spares) Standard delivery Standard delivery

Notes:

Included

Order processed by 14:00 Day 1 Delivery Day 2

>W eekday = Monday to Friday 8:00 to 17:00

Standard Hours (8:00 - 17:00) Timed Deliveries (excluding Spares) UK.DLVWIN1 8:00 - 13:00 weekdays UK.DLVWIN2 13:00 - 17:00 weekdays UK.TDN_30min Time specific 30 min window during standard hours

£50.00 £45.00 £220.00

Order processed by 14:00 Day 1 Delivery Day 2 Order processed by 14:00 Day 1 Delivery Day 2 Order processed by 14:00 Day 1 Delivery Day 2

Outside Standard UK.TDO_30min Time specific 30 min window outside standard hours UK.RUSH Same day delivery (geographical restrictions apply)

£290.00 £220.00

Order processed by 14:00 Day 1 Delivery Day 2 Order processed 11:00

Material Code

Description

Weekend Deliveries excluding Spares UK.TDO_30min Time specific 30 min window outside standard hours £290.00 Order processed by 14:00 Day 1 Delivery Day 3 or 4 (as requested) UK.SAT_Courrier Less than 15KG £35.00 Order processed by 14:00 Day 1 Delivery Day 2 UK.SAT_Sub Greater than 15KG £110.00 Order processed Day 1 Delivery Day 3 Public holidays - request for deliveries on public holidays are considered on an individual basis Special Vehicles Standard Delivery Monday to Friday UK.Special Hiab (includes time slot) Flat bed (includes time slot) UK.Van Transit van (size restrictions)

£340.00

Order processed by 14:00 Day 1 Delivery day 3

£100.00

Order processed by 14:00 Day 1 Delivery Day 2

MISCELLANEOUS

Special Vehicles Weekends UK.Special Hiab (includes time slot) £340.00 Order processed by 14:00 Day 1 Delivery Day 3 or 4 (as requested) Flat bed (includes time slot) UK.Van Transit van (size restrictions) £100.00 Order processed by 14:00 Day 1 Delivery Day 2 Public holidays - request for deliveries on public holidays are considered on an individual basis

162

Residential, Commercial and Industrial

> Standard delivery vehicle is 17.5 ton lorry or smaller with tail lift > Amendment or cancellation after order entry deadline maybe subject to additional costs > T ime specific is a requested delivery time plus or minus 30 mins > T wo man deliveries can be requested for heavier items and deliveries above ground level > Delivery address, site contact name and number are provided and any delivery restrictions must be communicated prior to order entry deadline > Driver is not permitted to make part delivery against a delivery note. Additional charges may apply for refused deliveries > 48 hours notice required for Hi-ab requests > 95% of mainland UK deliveries = next day > For Transportation Lead Times see http://www.daikin.co.uk/ business-partners/index.jsp


Goods Returns Procedure Daikin UK policy for acceptable returned goods Daikin UK policy for acceptable returned goods is as follows: Units & Accessories: 10 working days from date of invoice Spare Parts: 1 month from date of invoice

Daikin may accept unwanted goods provided they are boxed in the original packaging, in perfect condition and have not been used – provided they are also within the time scales of the Daikin returns policy. To arrange the process of returning goods, please complete a Goods Returns Form available from www.daikin.co.uk/business-partners/trade and send by fax or email to the following:

What Happens Next

Units & Accessories:

Once inspected and confirmation is received that the goods are in perfect condition, a credit will be raised against the original invoice.

Fax: 0845 641 9150 or email: returns@daikin.co.uk

Spare Parts:

Fax: 0845 641 9299 or email: spares@daikin.co.uk

Conditions of Returned Goods All returned items are subject to a minimum 20% restocking/ administration charge with the following collection charges applied to the final credit: Collected goods up to 15KG: ÂŁ15 Collected goods over 16KG: ÂŁ90

Once the Goods Return Form is received, an email will be sent to the confirmation email address provided notifying you of the goods for collection and a date for this to be carried out. If you have any queries regarding this date please respond to the email address provided as soon as possible.

*Please note returns for chillers and made to order units will not be accepted*

Goods Covered by Warranty Once a unit has been installed and commissioned, any faults or breakdowns that occur should be reported to our warranty department on: Telephone: 0845 641 9275 or email: warranty@daikin.co.uk

All returned goods will be fully inspected by our technical engineers. If returned goods are in a non-satisfactory condition then Daikin reserves the right to decline the return or apply an increase to the restocking charge.

Damaged Items We cannot accept claims for damages unless the goods are signed for as damaged on the delivery note and notification is received within 3 working days. Any damage identified can be refused at point of delivery.

MISCELLANEOUS

If you find that goods are damaged after they have been unpacked, please take photographs of the damage and contact the Returns Team immediately.

Price List 2015

163


The Field Quality Service department (FQS) The Field Quality Service department (FQS) supply a range of services to support the installer. Aftersales Technical Helpdesk

Workshop

This invaluable service offers technical support and guidance when you are experiencing on-site problems commissioning or diagnosing faults. Final diagnosis is the responsibility of the site engineer.

In our workshop on the outskirts of Bristol we modify standard Daikin equipment to current specifications that meet our client’s needs. The modifications include weatherised vams, floor mounted fan coil conversions, strip and rebuild to name a few. Think of the savings in time and money by having your next VRV outdoor unit delivered to site in sections for placing in position on the roof, saving at the cost of cranes and road closure applications. Speak to your sales representative for more information on what is available.

Your calls will be answered by Daikin trained engineers. To help provide a quick and efficient response please make sure you have the full model number of the unit. It is important to remind you that using the D1/D1+ PIN number gives you priority access to our engineers. Support for Air Conditioning contact: 0845 641 9200 Mon - Fri 8.30 - 17.30 Support for Heating contact: 0845 641 9277 Mon - Fri 8.30 - 20.00 & Sat 9.00 - 15.00 Email technicalhelp@daikin.co.uk SMS Fault Code Service 07797 801908

If you need an explanation and remedy on a fault code and haven’t got your service manual, just send the fault code to our SMS message service and we will advise you by return.

Field Service We can provide field engineers to assist you on-site for commissioning or service intervention. All work is documented in a report and sent for your records. Since we are working on your site on your behalf it is essential that you are in attendance at that time. To book an engineer contact us on: Tel 0845 641 9229 or contact us online at www.daikin.co.uk/service/support

Spares When a component fails, field expertise is pointless unless you have quick access to spares. Daikin have over 13,000 parts based in the UK, supported by our European parts centre with 700,000 parts. This helps us to achieve our target of providing 97% of critical A parts within a 2 day delivery. To contact the spares team directly Tel 0845 641 9230 Fax 0845 641 9299 Email spares@daikin.co.uk If you hold a direct account with Daikin UK, you can send your spare parts order to us directly using our Spares Parts Bank. This is available 24 hours a day 365 days a year, and allows you to view and order your parts online at any time of day. Plus, all orders processed through Spares Parts Bank have no delivery charge, which is equivalent to almost 5% extra discount. To register for Spares Parts Bank go to www.daikin.co.uk/spares

Daikin UK Warranty If you have a component failure and it is within the warranty period then we are here to help. After you have spoken to our helpdesk to confirm diagnosis, you can simply contact the warranty team.

For Heating email: heatingservice@daikin.co.uk For Air Conditioning email: air-conservice@daikin.co.uk Contact the warranty team on: Tel 0845 641 9275 Fax 0845 641 9298 Email warranty@daikin.co.uk

MISCELLANEOUS

For further details on Daikin’s warranty policies go to www.daikin.co.uk/service/warranty Here you will find process claim forms and our full warranty terms.

164

Residential, Commercial and Industrial


Daikin Service Tools Daikin Service App

Service Checker (Part No. 999165T)

The Daikin Service Application has been launched by Daikin Airconditioning UK to support service engineers in the air conditioning industry working with Daikin VRV Equipment.

The service checker type 3 can read and record the operational data from various Daikin equipment. This data consists of thermistor readings, pressure sensor values, solenoid valve operation, expansion valve pulses, operation modes etc. Software version 1.53 or later is required for connection to VRV IV systems.

It’s available for both the android and iPhone devices. The application covers various functions to help field engineers to fault find Daikin VRV equipment such as: Android functions Fault Codes VRV Additional Charge Calculation Replacement PCB Dip Switch Settings Pressure Transducer and Temperature Thermistor Checks Also various Outdoor Unit field settings including, Fan Coil and BSVQ Box Count Check Refrigerant Recovery Setting Outdoor Unit Emergency Modes VRV III & IV Short Test Run There is Also Daikin Altherma support for, Fault Codes Additional Refrigerant Charges C Series Altherma Field Settings Dip Switch Settings and much more...

iPhone functions Fault Codes VRV Additional Charge Calculation Replacement PCB Dip Switch Settings Pressure Transducer and Temperature Thermistor Checks Also various Outdoor Unit field settings including, Fan Coil and BSVQ Box Count Check Refrigerant Recovery Setting Outdoor Unit Emergency Modes VRV III Short Test Run

DChecker The DChecker is a service tool used to capture operational data from the following equipment, Split-Multisplit, Sky-air & Altherma products. This will record and graph all sensor data, PCB inputs & outputs from indoor and outdoor units. From the operational data this will help to identify any operational issue. Please note the DChecker is a USB interface which provides a direct wired link to the main PCBS and enables real-time data to be viewed on a laptop running windows. Software included.

Inverter Analyser RS UK0917A (Part No. 136 8521) The inverter analyser can be used to check the inverter outputs on all VRV models (can also be used on various split & sky air units).

To Download the Apps go to: Android: https://play.google.com/store/apps/details?id=com.daikin. aircon&hl=en

MISCELLANEOUS

iPhone: https://itunes.apple.com/us/app/daikin-service/id571282882?mt=8

Price List 2015

165


Daikin UK’s Customer Training

In 2015 Daikin UK will be introducing new and innovative training possibilities. We have spent 2014 investing in new Training Centres, Web Platforms and equipment upgrades. This year we will be focusing on ensuring that training you receive will be more relevant to the changing market and to assist you to provide your customers with the highest quality installations.

Training Centres

Daikin UK Training Centres

As well as upgrading our existing centres with new products, we have invested in two new centres in Woking and Birmingham.

1 Bristol Daikin Airconditioning UK Limited Maple House, Brotherswood Court, Great Park Road, Almondsbury, Bristol BS32 4QW

The Birmingham training centre covers an area of over 200m2 and is adjacent to the newly relocated sales office complex, providing hands on training on the latest Split, VRV, Altherma and control systems. The new Woking dedicated technology centre represents the largest Daikin training facility in the UK, over two floors, covering an area close to 1000m2. The facility is able to hold three training events at one time, with additional equipment demonstration facilities and a dedicated suite for conducting Web based live training events. The centre includes VRV Heat Recovery, VRV Heat Pump, Water Cooled VRV, Replacement VRV as well as a variety of split systems. With the increasing focus on energy controls, a specially designed controls wall has been constructed to allow for the many different configuration possibilities of individual and central controls together with the many BMS interface options.

2 Woking Daikin Airconditioning UK Limited 21 Woking Business Park, Albert Drive, Woking, Surrey GU21 5JY 3 Birmingham Daikin Airconditioning UK Limited 2470 Regents Court, The Crescent, Birmingham Business Park, Birmingham B37 7YE

5 Glasgow Daikin Airconditioning UK Limited Unit 2, Glasgow Airport Business Park, Marchburn Drive, Paisley PA3 2SJ 6 PGL Training Clyst Works, Clyst Road, Topsham, Exeter EX3 0DB 7 Dudley Energy Training Hub Dudley College Training Ltd 3-4 Railway Street, Great Bridge, Tipton DY4 7AD

4 Manchester Daikin Airconditioning UK Limited 17b Cobra Court, Blackmore Road, Manchester M32 0QY

The first floor is dedicated to Heating products with 8 individual working bays containing a wide selection of systems to allow for practical hands on training of commissioning and fault diagnosis. The award winning Altherma Hybrid system is installed in each of these 8 bays giving each attendee the possibility for a high level of experiential training.

Industry Accreditation

MISCELLANEOUS

Heat Pump courses with EAL accreditation are also available at our partner colleges. These courses count towards MCS (Microgeneration Certification Scheme), whilst at the same time providing the necessary knowledge to install Daikin Altherma Products. Our partner colleges include Dudley Energy Training Hub and PGL Training in Exeter. More details are available in the separate Daikin UK Training brochure.

To find out when courses are scheduled at regional Daikin UK training centres, check availability and book a place: please go to the Daikin UK booking web site at www.daikintraining.co.uk 166

Residential, Commercial and Industrial


Course Subjects

At the same time the demands on your time is increasing, and we have been looking at new and innovative ways to provide the knowledge and skills you need. During 2015 we will be introducing a wider range of courses together with new web based short courses that can be followed through whichever mobile platform you prefer. The new courses will cover more application and design subjects, Legislation, Fundamental Technical subjects and also personal development in areas such as Presentation and Selling skills. As these courses become available it will be possible to reserve places through our Web Based booking platform. We will announce more specific details throughout the year.

Within our new Woking Technology Centre we have installed a web based broadcast facility. From here we will provide a series of short courses across a range of subjects. The majority of these will also be recorded and made available through a new web based training platform that will be introduced by the middle of 2015. Users will be able to register as an individual to undertake web based training and each user will have a system account that enables them to review past training they have undertaken and the ability to print of training records and certificates. 2015 represents a change in our training approach that will provide you with a greater range of subjects, new ways to obtain skills and knowledge and more experiential classroom training. Further details can be found in the Daikin UK 2015 Training Brochure and on line at www.daikintraining.co.uk

MISCELLANEOUS

For anyone operating in the HVACR market, skills and knowledge requirements are getting wider with each year. Daikin UK recognise that our training offer needs to expand to provide opportunities to anyone operating in this industry.

Price List 2015

167


Freedom Air Conditioning Ltd Terms & Conditions 1. Definitions 1.1 “Buyer” means the person who buys or agrees to buy the goods from the Seller. 1.2 “Conditions” means the terms and conditions of sale set out in this document and any special terms and conditions agreed in writing by the Seller. 1.3 “Delivery date” means the date specified by the Seller when the goods are to be delivered. 1.4 “Goods” means the articles that the Buyer agrees to buy from the Seller. 1.5 “Price” means the price for the goods excluding carriage, packing, insurance and VAT. 1.6 “Seller” means all Subsidiaries wholly or partially owned by Freedom Air Conditioning Ltd 2. Conditions Applicable 2.1 These conditions shall apply to all Contracts for the sale of goods by the Seller to the Buyer to the exclusion of all other terms and conditions including any terms or conditions which the Buyer may purport to apply under any purchase order, confirmation or order or similar document. 2.2 All orders for goods shall be deemed to be an offer by the Buyer to purchase goods pursuant to these conditions. 2.3 Acceptance of delivery of the goods shall be deemed conclusive evidence of the Buyer’s acceptance of these conditions. 2.4 Any variation to these conditions (including any special terms and conditions agreed between the parties) shall not be applicable unless agreed in writing by the seller. 3. Price and Payment 3.1 The price shall be the Seller’s quoted price which shall be binding upon the sale providing that the Buyer shall accept the Seller’s quotation within 30 days. The price is exclusive of VAT which should be due at the rate ruling on the date of VAT invoice. 3.2 Payment of the price and VAT should be due within 30 days of the date of the invoice. Time for payment shall be of the essence. 3.3 Interest on overdue invoices shall accrue from the date when payment becomes due from day to day until the date of payment at a rate of 2% above Barclays Bank plc’s base rate from time to time in force and shall accrue at such a rate after as well as before any Judgement. 3.4 The Seller may by giving notice to the Buyer at any time up to 7 days before delivery increase the price of the goods to reflect any increase in the cost to the Seller which is due to factors occurring after the making of the Contract of Sale which are beyond the reasonable control of the Seller (including without limitation, foreign exchange fluctuations, taxes and duties and the cost of labour, materials and other manufacturing costs). Provided that the Buyer may cancel this Contract within 7 days of any such notice from the Seller. The price is exclusive of VAT which should be due at the rate ruling on the date of the VAT invoice. 4. The Goods 4.1 The goods shall be manufactured and supplied in accordance with the description contained in the Seller’s specification and manufactured in accordance with all applicable British standards which relate specifically to the goods. 4.2 The Seller may from time to time make changes in the specification of the goods which are required to comply with any applicable safety or statutory requirements or which do not materially affect the quality or fitness for the purpose of the goods. 4.3 The Buyer shall take delivery of the goods tendered notwithstanding that the quantity so delivered shall be either greater or less than the quantity purchased provided that: 4.3.1 Such discrepancy in quantity shall not exceed 5%

MISCELLANEOUS

4.3.2 The price shall be adjusted pro rata to the discrepancy

4.4 The Buyer shall inspect the goods on delivery and shall within three days of delivery notify the Seller of any alleged defects, shortage in quantity, damage or failure to comply with description or sample. The Buyer shall afford the Seller an opportunity to inspect the goods within a reasonable time following delivery and before any use is made of them. If the Buyer should fail to comply with these provisions the goods shall be conclusively presumed to be in accordance with the Contract and free from any defect or damage which would be apparent on a reasonable examination of the goods and the Buyer shall be deemed to have accepted the goods. 4.5 The Buyer shall notify the Seller of any non-delivery of a whole consignment within 14 days of the date of despatch (as stated on the invoice). Notwithstanding the receipt by the Seller of any such Notice a clear signature on a carrier’s delivery advice sheet shall be deemed simply by receipt of the quantity of goods indicated on the advice sheet. 4.6 If the goods are not in accordance with the Contract for any reason the Buyer’s sole remedy shall be limited to the Seller making good any shortage by replacing the goods or if the Seller shall elect, by refunding a proportion of part of the price. 5. Warranties and Liabilities 5.1 The Seller warrants that the goods will at the time if delivery corresponds to the description given by the Seller. 5.2 All terms, conditions and warranties (whether implied or made expressly) whether by the Seller or its servants or agents or otherwise (other than those express warranties set out in the current edition of the Seller’s specification) relating to the quality and/or fitness for the purpose of the goods or any of the goods are excluded. 5.3 In the event of any breach of this Contract by the Seller the Seller shall be under no liability whatever to the Buyer for any indirect loss and/or expense (including loss of profit) suffered by the Buyer. In the event of such breach the remedies of the Buyer shall be limited to damages. Under no circumstances shall the liability of the Seller exceed the price of the goods. 5.4 All warranties and conditions whether implied by statute or otherwise are excluded from this Contract. Providing that nothing in this Contract shall restrict or exclude liability for death or personal injury caused by the negligence of the Seller or affect the statutory rights of a Buyer dealing as a consumer. 6. Delivery of the Goods 6.1 Delivery of the goods shall be made to the buyer’s address on the delivery date. The buyer should make all arrangements necessary to take delivery of the goods whenever they are tendered for delivery. 6.2 The Seller may deliver the goods by separate installments. Each separate installment shall be invoiced and paid for in accordance with the provisions of this Contract of Sale. 6.3 The failure of the buyer to pay for any one or more of the said installments of the goods on the due date shall entitle the Seller (at the sole option of the Seller) 6.3.1 without notice to suspend further deliveries of the goods pending payment by the Buyer and/or 6.3.2 to treat this Contract as repudiated by the Buyer. 6.4 The Seller shall not be liable for any loss or damage whatsoever due to failure by the Seller to deliver the goods (or any of them) promptly or at all. 6.5 Notwithstanding that the Seller may have delayed or failed to deliver the goods (or any of them) promptly the Buyer shall be bound to accept delivery and to pay for the goods received. 7. Acceptance of the Goods 7.1 The Buyer shall be deemed to have accepted the goods 24 hours after delivery to the Buyer. 7.2 After acceptance the Buyer shall not be entitled to reject the goods which are not in accordance with the Contract. 7.3 If the Buyer properly rejects any of the goods which are not in accordance with the Contract the Buyer shall nonetheless pay the full price for such goods unless the Buyer promptly gives notice of rejection to the Seller and at the Buyer’s cost return such goods to the Seller before the date when payment of the price is due.

168

Residential, Commercial and Industrial


7.4 No goods delivered to the Buyer which are in accordance with the Contract will be accepted for return without the prior written approval of the Seller on terms to be determined at the absolute discretion of the Seller. 7.5 If the Seller agrees to accept any such goods for return the Buyer shall be liable to pay a handling charge of 10% of the invoice price. Such goods must be returned by the Buyer carriage paid to the Seller in their original shipping cartons. 7.6 Goods returned without the prior written approval of the Seller may at the Seller’s absolute discretion be returned to the Buyer or stored at the Buyer’s cost without prejudice to any rights or remedies the Seller may have. 8. Title and Risk 8.1 The goods shall be at the Buyer’s risk as from delivery. 8.2 In spite of delivery having been made property in the goods shall not pass from the Seller until 8.2.1 the buyer shall have paid the price plus VAT in full, and

9.5 The Seller will only be deemed to have accepted the return of the cylinders by acceptance of a record compiled by the Buyer of the cylinder numbers on the return cylinders which accords with the Seller’s original delivery notes. In the case of dispute this memorandum will be deemed to record the return of the cylinders. 9.6 The Buyer shall be liable to the Seller for all consequential loss, damage and expense caused by damage to or loss of the cylinders caused howsoever including force majeure. 9.7 Any residual gas remaining in the cylinder upon return will become the property of the Seller upon delivery. 9.8 Cylinders will be issued on a rent free basis for the first three months. Thereafter a monthly rental charge will be applied on the Seller’s standard charge as amended from time to time. A copy of the current charges will be supplied to the Buyer by the Seller upon request. 9.9 The Seller reserves the right to deem the cylinder as lost if not returned within 6 months from date of supply. In these circumstances a “Lost Cylinder Charge” will apply. A copy of the current charges will be supplied by the Seller upon request.

8.2.2 no other sums whatever shall be due from the Buyer to the Seller.

8.4 Notwithstanding that the goods (or any of them) remain the property of the Seller the Buyer may sell or use the goods in the ordinary course of the Buyer’s business at full market value for the account of the Seller. Any such sale or dealing shall be a sale or use of the Seller’s property by the Buyer on the Buyer’s own behalf and the Buyer shall deal as principal when making such sales or dealings. Until property in the goods passes from the Seller the entire proceeds of sale or otherwise of the goods shall be held in trust for the Seller and shall not be mixed with other money or paid into any overdrawn bank account and shall be at all material times identified as the Seller’s money. 8.5 The Seller shall be entitled to recover the price (plus VAT) notwithstanding that the property in any of the goods has not passed from the Seller. 8.6 Until such time as property in the goods passes from the Seller the Buyer shall upon request deliver up such of the goods as have not ceased to be in existence or re-sold to the Seller. If the Buyer fails to do so the Seller may enter upon any premises owned, occupied or controlled by the Buyer where the goods are situated and repossess the goods. On the making of such requests the rights of the Buyer under Clause 8.4 shall cease. 8.7 The Buyer shall not pledge or in any way charge by way of security for any indebtedness of any of the goods which are the property of the Seller. Without prejudice to the other rights of the Seller if the Buyer does so all sums whatever owing by the Buyer to the Seller shall forthwith become due any payable. 8.8 The Buyer shall insure and keep insured the goods to the full price against all risks to the reasonable satisfaction of the Seller until the date that property in the goods passes from the Seller and shall whenever requested by the Seller produce a copy of the policy of insurance. Without prejudice to the other rights of the Seller if the Buyer fails to do so all sums whatever owing by the buyer to the Seller shall forthwith become due and payable. 8.9 The Buyer shall promptly deliver the prescribed particulars of his Contract to the Registrar in accordance with the Companies Act 1985 part XII as amended. Without prejudice to the other rights of the Seller if the Buyer fails to do so all sums whatever owing by the Buyer to the Seller shall forthwith become due and payable. 9. Refrigerant Cylinders 9.1 The cylinders always remain the property of the Seller and title shall not pass from the Seller to the Buyer. 9.2 The Buyer shall hold the cylinders on a fiduciary basis as Bailee for the Seller. The Buyer shall store the cylinders at no cost to the Seller (separately from all other cylinders in its possession and marked in such a way that they are clearly identified as the Seller’s property). 9.3 The Buyer shall insure and keep insured the cylinders to the full price against all risk to the reasonable satisfaction of the Seller. 9.4 All cylinders when empty shall be returned in good condition by the Buyer to the Seller, carriage paid and in their original shipping cartons.

10. Industrial Gas Cylinders 10.1 The Industrial Gas cylinders always remain the property of the Seller and title shall not pass from the Seller to the Buyer. 10.2 The Buyer shall hold the cylinders on a fiduciary basis as Bailee for the Seller. The Buyer shall store the cylinders at no cost to the Seller (separately from all other cylinders in its possession and marked in such a way that they are clearly identified as the Seller’s property). 10.3 The Buyer shall insure and keep insured the cylinders to the full price against all risk to the reasonable satisfaction of the Seller. 10.4 All cylinders when empty shall be returned in good condition by the Buyer to the Seller, carriage paid and in their original shipping cartons. 10.5 The Seller will only be deemed to have accepted the return of the cylinders by acceptance of a record compiled by the Buyer of the cylinder numbers on the return cylinders which accords with the Seller’s original delivery notes. In the case of dispute this memorandum will be deemed to record the return of the cylinders. 10.6 The Buyer shall be liable to the Seller for all consequential loss, damage and expense caused by damage to or loss of the cylinders caused howsoever including force majeure. 10.7 Any residual gas remaining in the cylinder upon return will become the property of the Seller upon delivery. 10.8 Industrial Gas Cylinders will be issued on a rent free basis for the first three months. Thereafter a monthly rental charge will be applied on the Seller’s standard charge as amended from time to time. A copy of the current charges will be supplied to the Buyer by the Seller upon request. 10.9 Industrial Gas Cylinders will be issued on a Deposit basis. This Deposit will be credited to the Buyers account upon satisfactory return of the Cylinder to the Seller. A copy of the current charges will be supplied to the Buyer by the Seller upon request. 10.10 The Seller reserves the right to deem the cylinder as lost if not returned within 6 months from date of supply. In these circumstances a “Lost Cylinder Charge” will apply. A copy of the current charges will be supplied by the Seller upon request. 11. Severance Any provision of this Contract which is or may be void or unenforceable shall to the extent of such invalidity or unenforceability be deemed severable and shall not affect any other provision of this contract. 12. Waiver No waiver of forbearance by the Seller (whether expressed or implied) in enforcing any of its rights under this Contract shall prejudice its right to do so in the future. 13. Insolvency If the Buyer fails to make payment for the goods in accordance with its Contract of Sale or commits any other breach of its Contract of Sale or if any distress or execution shall be levied upon any of the Buyer’s goods or if the Buyer offers to make any arrangements with its creditors or if any Petition is presented against the Buyer or the Buyer is unable to pay its debts as they fall due or if being a Limited Company any resolution or Petition

Price List 2015

169

MISCELLANEOUS

8.3 Until property in the goods passes to the Buyer in accordance with Clause 8.2 the Buyer shall hold the goods and each of them on a fiduciary basis as Bailee for the Seller. The Buyer shall store the goods at no cost to the Seller (separately from all other goods in its possession and marked in such a way that they are clearly identified as the Seller’s property).


to wind up the Buyer (other than for the purpose of amalgamation or reconstruction without insolvency) shall be passed or presented or if a Receiver, Administrative Receiver or Manager shall be appointed over the whole or any part of the Buyer’s business or assets or if any Petition for the appointment of any Administrator is presented against the Buyer or if the Buyer shall suffer any analogous proceedings under foreign law all sums outstanding in respect of the goods shall become payable immediately. The Seller may in its absolute discretion without prejudice to any other rights which it may have i. suspend all future deliveries of goods to the Buyer and/or terminate the Contract without liability on its part, and/or

MISCELLANEOUS

ii. exercise any of the rights pursuant to Clause 8.

170

Residential, Commercial and Industrial

14. Proper Law of Contract 14.1 This Contract is subject to the Law of England and Wales. 14.2 All disputes arising out of this Contract shall be subject to the exclusive jurisdiction of the Courts of England and Wales. 15. Force Majeure Notwithstanding any other provision of the conditions the seller shall not be liable in any way for loss or damage resulting from the failure to supply any of the goods, for any delay or defect in the supply of any of the goods caused by force majeure or strike, lockout, industrial action, accident, fire, scarcity of materials or labour or any other cause not within the Seller’s direct control.


Freedom Air Conditioning From its inception Freedom has had one goal in mind, a better service to contractors. It’s founders, directors and management team all started in contracting and as such understand the needs and demands that are put upon our customers. To ensure an outstanding service we have in-house design, dedicated technical support and experienced logistics teams all ready to be a natural extension to your business.

We are committed to making the life of our customers easier. Our technical support lines are manned by qualified field experienced service engineers and our sales teams (and indeed our owners) started on the tools and understand what you need. Air Conditioning Division Unit 5, St Georges Industrial Estate Goodwood Road, Eastleigh Hampshire SO50 4NT Telephone 02380 653283

Heat Pumps Division Unit 2, Warrior Park, Eagle Close School Lane, Chandlers Ford Hampshire SO53 4NF Telephone 02380 274833

Conditions Capacity Conditions

Seasonal Efficiency

Unit cooling and heating capacities shown within this price list are based on the following conditions:

Split and Sky Air

Nominal cooling Ambient = 35°C Internal = 27°C db 19°C wb

Nominal heating Ambient = 7°C db 6°C wb Internal = 20°C db

UK cooling Ambient = 30°C Internal = 22°C db 16°C wb

Systems of up to 12kW must now show Seasonal Efficiency Ratings instead of Nominal Efficiency Ratings. These ratings (SEER for cooling, SCOP for heating) represent how effective a system is throughout the year, and are in accordance with EN14825. For more information on Seasonal Efficiency, visit www.daikin.co.uk/seasonal-efficiency For Daikin UK, this means all our Split and Sky Air products up to 12kW display SEER and SCOP data along with Energy Label information and Annual Energy Consumption of the system. The AEC is based upon 500 hours use per year.

VRV (ESEER)

Heat Source

ESEER is defined as the European Seasonal Energy Efficiency Ratio and is a measure of the performance of the outdoor unit only.

Unless otherwise indicated, all units within this price list are air-cooled.

Nominal Efficiency This measure of efficiency is calculated by dividing the capacity output of a unit by the power required to deliver it. For cooling, this is expressed as EER, for heating as COP. Nominal efficiencies are used for systems above 12kW. It is not possible to compare nominal and Seasonal Efficiency ratings.


Daikin UK Price List 2015

Daikin UK Price List

2015

Air Conditioning Division Unit 5, St Georges Industrial Estate Goodwood Road, Eastleigh Hampshire SO50 4NT Telephone 02380 653283 Heat Pumps Division Unit 2, Warrior Park, Eagle Close School Lane, Chandlers Ford Hampshire SO53 4NF Telephone 02380 274833

Residential, Commercial and Industrial


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.