Nanocolor analyse systemet

Page 1

MACHEREY-NAGEL

NANOCOLOR®

The system for photometric water analysis nnExpertise nnContinuity nnPassion

Water Analysis


NANOCOLOR® analysis system 40 years of expertise, continuity and passion for our customers

For over 40 years MACHEREY-NAGEL has been developing solutions in the field of photometry. Continious equipment and software development, extraordinary close customer relations and passion for our work allow us to offer you the NANOCOLOR® system with high reliability and quality. nnISO-certified production in Germany ensuring highest quality “Made in Germany“ nnConsistent quality from batch to batch – no LOT-specific updates required nnMSDS, user manuals and LOT-specific certificates nnIntensive Research and Development in the field of water analysis to meet future demands and requirements nn One-on-One service through our trained distributors on site and our Customer Service Center in Dueren, Germany

Equipment and devices

High quality compact photometers, spectrophotometer and heating blocks

Customer service

Tests and platforms

Competent technical experts team behind the scenes

!

2

?

The perfect test for every request

Quality control

Complete internal quality control with the NANOCONTROL system

NANOCOLOR® 25

NANOCOLOR® CSB/COD

NANOCOLOR® 50 D

NANOCOLOR® 100 D

NANOCOLOR® 200 D

NANOCOLOR® R 450

NANOCOLOR® 300 D

NANOCOLOR® VARIO 1

NANOCOLOR® 500 D

NANOCOLOR® PF-12

NANOCOLOR® VIS

NANOCOLOR® VARIO 4

www.mn-net.com


NANOCOLORÂŽ analysis system 16 mm test tubes in convenient packaging for safe and easy handling

NANOCOLORÂŽ reagents impress by easy handling and are suited for routine analysis, self-monitoring and process control. 16 mm round tubes with pre-dosed reagents guarantee a maximum safety for the user. nnRugged boxes with perfect light protection nnClever packages suitable to serve as a test tube holder nnColor coded labels with all important information nnColored pictograms on package lid for perfect test execution nnConvenient and safe removal of test tubes nnDescribable top-label enabling an explicit allocation of test tubes nnWide test tube openings for easy handling and safe pipetting

www.mn-net.com

3


NANOCOLOR® analysis system The perfect COD test for each and every user

For one of the most important parameters for determination of industrial and municipal waste water MACHEREY-NAGEL offers you even 12 different tests and measurement ranges. At the same time our COD tests allow safe handling without any risk from outgoing dichromate and mercury gases. Even after the REACH restrictions in the year 2017, our customers can continue using our NANOCOLOR® COD cuvette tests without limitation. nn12 measurement ranges for all requirements and demands nnReaction base according to ISO 6060 nn7 COD tests compliant with ISO 15705 nnNo zero measurement required nnAudited and certified: no mercury exposure for users nnMercury-free COD tests available for inflow and outflow measurements

Certificate ISO conformity of NANOCOLOR ® tube tests

Certificate

COD 40 COD 60 COD LR 150* COD 160 COD 600 COD 1500 COD HR 1500*

REF 985 027 REF 985 022 REF 985 036 REF 985 026 REF 985 030 REF 985 029 REF 985 038

ISO conformity of NANOCOLOR ® tube tests

Hereby we confirm, that the above mentioned tube tests from MACHEREY-NAGEL correspond in all points with the

ISO 15705 “Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed tube method”. MACHEREY-NAGEL

ISO 15705

Reagents

Sulfuric acid Potassium dichromate Silver sulfate Mercury sulfate

Sulfuric acid Potassium dichromate Silver sulfate Mercury sulfate

Sample volume

2.00 mL

2.00 ± 0.02 mL

Digestion

Temperature: Time: * Digestion temperature 150 °C

Wavelengths for photometric determination

2 5 3 15 50 100 20

-

40 60 150 160 600 1500 1500

148 °C 2h

mg/L O2 mg/L O2 mg/L O2 mg/L O2 mg/L O2 mg/L O2 mg/L O2

345 nm 345 nm 436 nm 436 nm 620 nm 620 nm 620 nm

Temperature: Time:

150 ± 5 °C 2 h ± 10 min

to to to to to to to

348 ± 15 nm 348 ± 15 nm 440 ± 20 nm 440 ± 20 nm 600 ± 20 nm 600 ± 20 nm 600 ± 20 nm

50 50 150 150 1000 1000 1000

mg/L O2 mg/L O2 mg/L O2 mg/L O2 mg/L O2 mg/L O2 mg/L O2

HE

REY

MA

19.09.2014

i. A.

GEL

D

MACHEREY-NAGEL GmbH & Co. KG

ÜR

ISO 15705

EN

Dr. Reinhardt, Head of QC www.mn-net.com

EN ISO 9001: 2008 CERTIFIED

MACHEREY-NAGEL GmbH & Co. KG · Neumann-Neander-Str. 6-8 · D-52355 Düren · Germany Switzerland: Germany France: MACHEREY-NAGEL AG and international: MACHEREY-NAGEL EURL Tel.: +41 388 55 00 Tel.: +49 24 21 969-0 Tel.: +33 388 68 22 68 FAX: +41 388 55 05 FAX: +49 24 21 969-199 FAX: +33 388 51 76 88 Mail: info-ch@mn-net.com Mail: info@mn-net.com Mail: info-fr@mn-net.com

REF 985 027 REF 985 022 REF 985 036 REF 985 026 REF 985 030 REF 985 029 REF 985 038

Hereby we confirm, that the above mentioned tube tests from MACHEREY-NAGEL correspond in all points with the

-

NA

C

Düren,

COD 40 COD 60 COD LR 150* COD 160 COD 600 COD 1500 COD HR 1500*

“Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed tube method”.

USA: MACHEREY-NAGEL EURL Tel.: +1 484 821 0984 FAX: +1 484 821 1272 Mail: info-us@mn-net.com

MACHEREY-NAGEL

ISO 15705

Reagents

Sulfuric acid Potassium dichromate Silver sulfate Mercury sulfate

Sulfuric acid Potassium dichromate Silver sulfate Mercury sulfate

Sample volume

2.00 mL

2.00 ± 0.02 mL

Digestion

Temperature: Time: * Digestion temperature 150 °C

Wavelengths for photometric determination

2 5 3 15 50 100 20

-

40 60 150 160 600 1500 1500

148 °C 2h

mg/L O2 mg/L O2 mg/L O2 mg/L O2 mg/L O2 mg/L O2 mg/L O2

345 nm 345 nm 436 nm 436 nm 620 nm 620 nm 620 nm

Temperature: Time:

150 ± 5 °C 2 h ± 10 min

to to to to to to to

348 ± 15 nm 348 ± 15 nm 440 ± 20 nm 440 ± 20 nm 600 ± 20 nm 600 ± 20 nm 600 ± 20 nm

50 50 150 150 1000 1000 1000

mg/L O2 mg/L O2 mg/L O2 mg/L O2 mg/L O2 mg/L O2 mg/L O2

HE

REY

MA

Düren,

19.09.2014

i. A.

GEL

D

MACHEREY-NAGEL GmbH & Co. KG

-

NA

C

ÜR

EN

Dr. Reinhardt, Head of QC www.mn-net.com

EN ISO 9001: 2008 CERTIFIED

4

www.mn-net.com

MACHEREY-NAGEL GmbH & Co. KG · Neumann-Neander-Str. 6-8 · D-52355 Düren · Germany Switzerland: Germany France: MACHEREY-NAGEL AG and international: MACHEREY-NAGEL EURL Tel.: +41 388 55 00 Tel.: +49 24 21 969-0 Tel.: +33 388 68 22 68 FAX: +41 388 55 05 FAX: +49 24 21 969-199 FAX: +33 388 51 76 88 Mail: info-ch@mn-net.com Mail: info@mn-net.com Mail: info-fr@mn-net.com

USA: MACHEREY-NAGEL EURL Tel.: +1 484 821 0984 FAX: +1 484 821 1272 Mail: info-us@mn-net.com


NANOCOLORÂŽ analysis system Time-saving and reliable analysis of total nitrogen

The proven NANOCOLORÂŽ total nitrogen tests are perfectly suited for the reliable determination of total nitrogen in waste water. Beside reproducible results they offer you a very simple and fast handling. nnOne single test tube for each digestion nnNo contamination since digestion tubes are never used twice nnNo cleaning of digestion tubes required nnLess testing steps through prefilled digestion reagents nnSafe results through sufficiently large sample-volumes

www.mn-net.com

5


NANOCOLOR速 analysis system Smart photometry The new Spectrophotometers NANOCOLOR速 UV/VIS II and VIS II

MACHEREY-NAGEL is revolutionizing your daily laboratory work with the new spectrophotometers NANOCOLOR速 UV/VIS II and NANOCOLOR速 VIS II and combines a superior quality, high-tech electronic device with an outstanding usability. Operate this innovative photometer like your smartphone or tablet and enjoy the intuitive, icon-based operation every day in a new way. Due to the clearly arranged and high-resolution touch screen display, the daily measurement routine will become a pleasure. nnRevolutionary user experience by 10 inch HD touch screen display nnIntuitive and completely icon-based menu guidance nnIntegrated turbidity control (NTU-Check) and CIE-conform color measurements nnCompletely inbuilt equipment monitoring functions and printing of certificates nnIntegrated lamp test and stray light according to Ph.Eur. nnWavelenght-correctness test with integrated Holmium oxide filter

Smart photometry

6

www.mn-net.com


NANOCOLOR® analysis system Automatic turbidity check for tube tests

Despite careful working procedures and constant quality control, turbidity is often underestimated as a source of error in photometric water analysis which can lead to significant deviations in measuring values up to 30 %. To increase result safety for users, MACHEREY-NAGEL has integrated a unique turbidity control function (NTU-Check) for tube tests into our spectrophotometers. nnInnovative and unique solution for turbidity problems, warns in case of potential interferences nnElimination of a frequently underestimated source of errors in the field of photometry nnTurbidity displayed directly in NTU according to EN ISO 7027 nnMaximum measurement accuracy nnOutstanding results in COD analysis nnComplete documentation through parallel storage of measurements and NTU values nnConvenient turbidity calibration with NANOCONTROL NANOTURB

2 t ube s ( A / B ) w it h t he sa me COD c onc e nt r a t ion

www.mn-net.com

7


NANOCOLOR速 analysis system Convenient data export to LIMS and other standard PC-programs

In modern laboratories dealing with water and waste water analysis, the combination of the different data sets and test results is getting more and more important. Using the free of charge NANOCOLOR速 PC software, the data from NANOCOLOR速 spectrophotometers can be elegantly integrated into various laboratory information systems. This is going to be easier and even more efficient employing novel photometer updates. nnFree of charge PC Software with numerous additional features nnEasy data transfer to Microsoft速 Excel

nnAutomated compilation of original files for tamper-proof data storage in accordance with FDA 21 CFR Part 11 nnConnection to laboratory information systems (LIS) using tailor-made data configuration tools nnEfficient documentation of measurement results nnFast and easy data management according to GLP

8

www.mn-net.com


NANOCOLORÂŽ analysis system Future-proof heating blocks for reliable sample digestion

The NANOCOLORÂŽ heating blocks enable a fast and safe performance of all required digestions. The preprogrammed standard parameter for all routine digestions, e.g. for COD, TOC, total nitrogen, total phosphate and metals help avoid errors. nn2 separate heating units for parallel rapid digestion of COD, total nitrogen and total phosphate nnTouch screen with intuitive menu navigation for easy handling nnLockable protective lids and safety covers for maximum protection nnUSB interface for future-proof PC connection nnGraphical monitoring of heating curves nnExtremely short heating times translate into time savings for the user nnHigh temperature stability for consistent digestion conditions nnEasily replaceable spare parts

27-05-2015 12:15:00

www.mn-net.com

9


NANOCOLOR速 analysis system NANOCOLOR速 T-Set Automatic heating block control and calibration

The unique NANOCOLOR速 T-Set is an electronic temperature sensor for temperature control and fully automatic calibration of the heating blocks. nnCalibrated temperature sensors made to monitor digestion temperatures nnEasy monitoring of temperature stability through external recordings of heating curves nnNANOCOLOR速 T-Set also suitable as a universal thermometer for external temperature measurements nnConvenient data transfer via USB interface nnGLP conform documentation with automatically generated inspection reports

10

www.mn-net.com


NANOCOLOR速 analysis system Quality control for photometric water analysis

With the NANOCONTROL system MACHEREY-NAGEL offers you a complete range of products for analytical quality control for all analyses carried out with our NANOCOLOR速 system. It gives you options to check all NANOCOLOR速 reagents and test kits, photometers, heating blocks and your personal handling and work flow, thus providing 360 degree feedback on your analytical work. nnMeasurement of single and multi standards with NANOCONTROL nnPlausibility checks with NANOCONTROL addition solutions nnHeating block inspection with the NANOCOLOR速 T-Set nnPhotometer inspection with the NANOCONTROL NANOCHECK nnConvenient turbidity calibration with NANOCONTROL NANOTURB

www.mn-net.com

11


NANOCOLOR® analysis system NANOCOLOR® photometer – At a glance NANOCOLOR® UV/VIS II

nnHigh precision spectrophotometer with outstanding usability nn Nephelometric stray light measurement from 0.1 – 1000 NTU nn Integrated f.o.c. inspection equipment monitoring REF 919 600

NANOCOLOR® VIS II

nnRevolutionary user experience by 10 inch HD touch screen display nnIntegrated turbidity measurement (NTU-Check) nnInternal quality control functions REF 919 650

NANOCOLOR® 500 D

nnFastest digital photmeter on the market nnShock proof according to German military standard nnInbuilt battery REF 919 500

Compact photometer PF-12Plus

nn Flexible filter photometer with more than 100 preprogrammed methods nnNephelometric turbidity measurements nn Integrated turbidity control (NTU-Check) REF 919 250

Compact photometer PF-3

nnLightweight and robust by very compact dimensions nn Intuitive operation using just 4 buttons nnDifferent versions for different applications available PF-3 Pool

REF 934 102

PF-3 Drinking Water

REF 934 402

PF-3 Soil

REF 934 202

PF-3 COD

REF 934 302

12

www.mn-net.com


NANOCOLOR® analysis system NANOCOLOR® heating blocks – At a glance NANOCOLOR® VARIO 4

nnSimultaneous digestion of 24 samples nnTwo independently usable heating units nnThe most flexible solution REF 919 300

NANOCOLOR® VARIO C2

nnSimultaneous digestion of 12 samples nnThe ideal choice for small sample amounts nnCost-effective quality REF 919 350

NANOCOLOR® VARIO C2 M

nnSimultaneous digestion of 12 samples nn Heating block for metall analysis with big bores nnDigestion of big and small reaction glasses REF 919 350.1

NANOCOLOR® VARIO HC

nnSimultaneous digestion of 12 samples nnActive rapid cooling after digestion nnHeating unit with aerator REF 919 330

www.mn-net.com

13


NANOCOLOR® analysis system NANOCOLOR® tube tests – At a glance Test Alcohol, see Ethanol and Methanol Aluminum 07 Ammonium 3 * Ammonium 10 * Ammonium 50 * Ammonium 100 * Ammonium 200 * Anionic surfactants see Surfactants AOX 3 * BOD5 (in Winkler bottles) * BOD5-TT * Cadmium 2 Carbonate hardness 15 Cationic surfactants see Surfactants Chloride 200 * Chloride 50 * Chlorine / Ozone 2 * Chlorine dioxide 5 Chromate 5 total Chromium 2 * COD 40 * COD 60 * COD 160 * COD 160 Hg-free * COD 300 * COD 600 * COD 1500 * COD 4000 * COD 10000 * COD 15000 * COD 60000 * COD LR 150 * COD HR 1500 * org. Complexing agents 10 Copper 5 Cyanide 08 * DEHA 1 (Diethylhydroxylamine) Ethanol 1000 Fatty acids see Organic acids Fluoride 2 Formaldehyde 8 * Formaldehyde 10 Hardness Ca / Mg Hardness 20 HC 300 (Hydrocarbons) * Iron 3 * Lead 5 * Manganese 10 * Methanol 15 Molybdenum 40 * Nonionic surfactants, see Surfactants Nickel 4 * Nitrate 8 * Nitrate 50 * Nitrate 250 * Nitrite 2 * Nitrite 4 total Nitrogen TNb 22 * total Nitrogen TNb 60 * total Nitrogen TNb 220 * Organic acids 3000 * Oxygen 12 * Ozone, see Chlorine / Ozone 2 Peroxide 2 pH 6.5–8.2 Phenolic index 5 *

14

www.mn-net.com

Measuring ranges

REF

0.02–0.70 mg/L Al3+ 0.04–2.30 mg/L NH4-N 0.2–8.0 mg/L NH4-N 1–40 mg/L NH4-N 4–80 mg/L NH4-N 30–160 mg/L NH4-N

985 098 985 003 985 004 985 005 985 008 985 006

0.1–3.0 mg/L AOX 2–3000 mg/L O2 0.5–3000 mg/L O2 0.05–2.00 mg/L Cd2+ 1.25–18.75 °e

985 007 985 822 985 825 985 014 985 015

5–200 mg/L Cl– 0.5–50.0 mg/L Cl– 0.05–2.50 mg/L Cl2 0.15–5.00 mg/L ClO2 0.05–2.00 mg/L Cr(VI) 0.005–0.500 mg/L Cr(VI) 0.05–2.00 mg/L Cr 2–40 mg/L O2 5–60 mg/L O2 15–160 mg/L O2 15–160 mg/L O2 50–300 mg/L O2 50–600 mg/L O2 100–1500 mg/L O2 400–4000 mg/L O2 1.00–10.00 g/L O2 1.0–15.0 g/L O2 5.0–60.0 g/L O2 3–150 mg/L O2 20–1500 mg/L O2 0.5–10.0 mg/L IBiK 0.10–7.00 mg/L Cu2+ 0.02–0.80 mg/L CN– 0.05–1.00 mg/L DEHA 0.10–1.00 g/L EtOH

985 019 985 021 985 017 985 018 985 024 985 059 985 027 985 022 985 026 963 026 985 033 985 030 985 029 985 011 985 023 985 028 985 012 985 036 985 038 985 052 985 053 985 031 985 035 985 838 985 040 985 041 985 046 985 044

0.1–2.0 mg/L F– 0.1–8.0 mg/L HCHO 0.20–10.00 mg/L HCHO 1.25–25.0 °e / 5-50 mg/L Mg2+ 0.2–3.6 mmol/L / 10-100 mg/L Ca2+ 1.25–25.0 °e 0.2–3.6 mmol/L 0.5–5.6 mg/L KW 0,10–3,00 mg/L Fe 0.10–5.00 mg/L Pb2+ 0.1–10.0 mg/L Mn 0.2–15.0 mg/L MeOH 1.0–40.0 mg/L Mo(VI)

985 057 985 037 985 009 985 058 985 859 985 056

0.10–7.00 mg/L Ni2+ 0.30–8.00 mg/L NO3-N 0.3–22.0 mg/L NO3-N 4–60 mg/L NO3-N 0.003–0.460 mg/L NO2-N 0.1–4.0 mg/L NO2-N 0.5–22.0 mg/L N 3–60 mg/L N 5–220 mg/L N 30–3000 mg/L CH3COOH 0.5–12.0 mg/L O2

985 071 985 065 985 064 985 066 985 068 985 069 985 083 985 092 985 088 985 050 985 082

0.03–2.00 mg/L H2O2 pH 6.5–8.2 0.2–5.0 mg/L Phenol

985 871 918 72 985 074

985 043


NANOCOLOR® analysis system Test

Measuring ranges

REF

ortho and total Phosphate 1 *

0.05–1.50 mg/L P 0.010–0.800 mg/L P 0.20–5.00 mg/L P 0.30–15.00 mg/L P 5.0–50.0 mg/L P 10.0–50.0 mg/L P 20–200 mg/L POC 2–50 mg/L K+ 0.03–1.25 °e 0.20–3.00 mg/L Ag+ 5–100 mg/L starch 10–200 mg/L SO42– 200–1000 mg/L SO42– 0.05–3.00 mg/L S2– 0.2–10.0 mg/L SO32– 5–100 mg/L SO32– 0.20–4.00 mg/L MBAS 0.20–4.00 mg/L CTAB 0.3–15.0 mg/L Triton® X-100 0.5–50.0 mg/L SCN– 0.10–3.00 mg/L Sn 2.0–25.0 mg/L C 10–60 mg/L C 40–600 mg/L C 5–150 μg TPF 0.10–4.00 mg/L Zn2+

985 076

ortho and total Phosphate 5 * ortho and total Phosphate 15 * ortho and total Phosphate 45 * ortho and total Phosphate 50 * POC 200 Potassium 50 * Residual hardness 1 Silver 3 Starch 100 * Sulfate 200 * Sulfate 1000 * Sulfide 3 * Sulfite 10 * Sulfite 100 * Anionic surfactants 4 * Cationic surfactants 4 * Nonionic surfactants 15 * Thiocyanat 50 * Tin 3 * TOC 25 * TOC 60 * TOC 600 * TTC / Sludge activity 150 * Zinc 4 *

* These products contain harmful substances which must be specially labeled as hazardous. For detailed information please see MSDS.

985 081 985 080 985 055 985 079 985 070 985 045 985 084 985 049 985 085 985 086 985 087 985 073 985 089 985 090 985 032 985 034 985 047 985 091 985 097 985 093 985 094 985 099 985 890 985 096

NANOCOLOR® standard tests – At a glance Test

Measuring ranges

REF

Aluminum Ammonium * Chloride * Chlorine * Chlorine dioxide * Chromate * Cobalt * Color (Hazen/DIN) Copper Cyanide * Fluoride * Hydrazine * Iron * Manganese * Nickel * Nitrate * Nitrate Z * Nitrite * Phenol * ortho Phosphate * ortho Phosphate * Silica *

0.01–1.00 mg/L Al3+ 0.01–2.0 mg/L NH4-N 0.2–125 mg/L Cl– 0.02–10.0 mg/L Cl2 0.04–4.00 mg/L ClO2 0.01–3.0 mg/L Cr(VI) 0.002–0.70 mg/L Co2+ 5–500 mg/L Pt (Hazen) 0.01–10.0 mg/L Cu2+ 0.001–0.50 mg/L CN– 0.05–2.00 mg/L F– 0.002–1.50 mg/L N2H4 0.01–15.0 mg/L Fe 0.01–10.0 mg/L Mn 0.01–10.0 mg/L Ni2+ 0.9–30.0 mg/L NO3-N 0.02–1.0 mg/L NO3-N 0.002–0.30 mg/L NO2-N 0.01–7.0 mg/L Phenol 0.04–6.5 mg/L PO4-P 0.2–17 mg/L PO4-P 0.01–5.00 mg/L Si 0.002–0.100 mg/L Si 3) 0.01–3.0 mg/L S2– 1–100 TE/F (= FAU) 1–1000 NTU 0.02–3.0 mg/L Zn2+

918 02 918 05 918 20 918 16 918 163 918 25 918 51 Test 1-39 918 53 918 30 918 142 918 44 918 36 918 60 918 62 918 65 918 63 918 67 918 75 918 77 918 78 918 48

Sulfide * Turbidity (formazine/DIN) Turbidity Zinc *

* These products contain harmful substances which must be specially labeled as hazardous. For detailed information please see MSDS.

918 88 Test 1-92 Test 9-06 918 95

www.mn-net.com

15


Image credits: © 4uphoto – fotolia.de · Printed in Germany KATEN100165/NANOCOLOR en2/3/0/10.2015 DD

MACHEREY-NAGEL GmbH & Co. KG · Neumann-Neander-Str. 6–8 · 52355 Düren · Germany Germany and international:

Tel.: +49 24 21 969-0 Fax: +49 24 21 969-199 E-mail: info@mn-net.com

Switzerland: MACHEREY-NAGEL AG

Tel.: +41 62 388 55 00 Fax: +41 62 388 55 05 E-mail: sales-ch@mn-net.com

France: MACHEREY-NAGEL EURL

Tel.: +33 388 68 22 68 Fax: +33 388 51 76 88 E-mail: sales-fr@mn-net.com