One of the most powerful a compact WROV on the subsea marked to day
Shipping and Crane-age Details The Cougar system is shipped out in two lifts Max Gross
Dimensions mm
Lift nr
Description
Weight
(L x W x H)
1
ROV in a box
10,000 kg
6058x2500x 2591
2
Spare Tether
600 kg
On a pallet
Lift No 1 ROV in a Box This A60 container holds the vehicle, ROV control system, winch
ROV in a Box Control Cabin, Lift 1
and integral power pack. System spares are stored inside the container. Lift No 2 Spare tether This is the spare tether and is mounted on a pallet.
Vessel Services Required
ISO Corner Castings
One stable supply of 67kVA 380 – 440v 3 phase 50/60Hz to power the ROV system. This supply must be Motor Rated. Recommended breaker is 100A.
• Connection to vessel Fire and Gas Alarm if required. • Connection to Vessel USBL/HPR navigation system. • Connection of telephone to vessel communications system. • Connection to vessel electronic mail system. • Suitable crane and operator for Launch and recovery of the ROV. Crane will require a pad eye for shackle to umbilical sheave. • Twist -lock connectors for system sea-fastening. • Access to freshwater for vehicle wash down. Outline Drawing of ROV
Subsea Services
Cougar XT ROV in a box Specifications for Mobilisation
Cougar XT ROV in a box Specifications for Mobilisation Electrical Mobilization
FSAS Supplied Equipment Checklist
The Seaeye Cougar System requires one supply, a 67kVA 3Ø
Cougar ROV in a Box System.
50/60 Hz motor rated supply for the complete system. Maximum current is 161A; recommended Motor Rated Breaker is 100A. The system is supplied with a power cable of 60m length, 16 mm2 , 4-core cable rated to 200A. Electrical connection of the system, including fire alarm, telephone etc will be completed by the vessel electrician or, in accordance with his instructions. All cable runs shall be secure and tidy; cable routes shall be agreed with the vessel electrician. Earth bosses shall be connected to all containers that have electrical supplies.
• Complete with power cable of 60m, no plug on end. 16mm2, 4 core 200A rated • Connection of hard wired communications system between Control, survey, bridge and crane. Cable and communications equipment. • Deck fastening plates if required • Spare tether
Vessel Services Required to Mobilize System Checklist • One stable supply of 67kVA 380 – 440v 3 phase 50/60Hz to power the ROV system. This supply must be Motor
Communications between ROV control container, bridge, survey and crane shall be by hard-wired communication system (FSAS supplied)
Rated. Recommended breaker is 100A. • Connection to vessel Fire and Gas Alarm if required. • Connection to Vessel USBL/HPR navigation system.
Positioning of Equipment and Deck Loading The system will be positioned on board the vessel under instructions from the vessel master. The ROV supervisor will provide guidance on this, in particular the fleet angle of the umbilical from the winch to the sheave under the crane.
• Connection of telephone to vessel communications system. • Connection to vessel electronic mail system. • Suitable crane and operator for Launch and recovery of the ROV. Crane will require a pad eye for shackle to umbilical sheave. (ROV weight is 550kg) • Twist-lock connectors for system sea-fastening. • Access to freshwater for vehicle wash down.
The system will normally be deck fastened using Twist locks, (Vessel supplied equipment.) If system has to be welded to the deck then FSAS will supply the tie down plates and I or H beams. Any welds shall be inspected using magnetic particle detection. A qualified person shall carry this out. The spare tether shall be securely sea fastened in a sheltered area.
Client Supplied Services Checklist • Welders for deck fastening if twist-locks not used. • Inspection engineer. • Crane and dockside labour for loading and positioning of the equipment.
This document includes technical information. Reasonable effort has been made to verify its correctness at the time of compilation but details may change with the passage of time and without prior notice. Fugro does not accept any liability for loss or damage of any kind arising from use of the information.
Fugro RUE AS Stoltenberg 1 5527 Haugesund Norway Telephone : +47 52 86 48 20 fras@fugro.no