Cassette Range Ceiling Cassettes
Ceiling Cassette Range
Why choose Fujitsu?
Visually Discreet The Fujitsu range of cassettes are visually discreet, with a compact, non-intrusive grille design* that sits neatly under the ceiling.
Specialist expertise
Advanced Air Filters
Even Temperature Distribution
New Zealand’s only accredited installation programme
6 Year Manufacturer’s Warranty*
Trusted brand
Incorporating Fujitsu’s latest fan design and technology, air can be distributed throughout the space in multiple directions, providing even temperature distribution and all-round comfort.
Energy Efficiency Energy management features such as programmable weekly timers, a sleep timer and economy mode offers an efficient cooling and heating solution. The cassette range are ideal for larger open plan spaces, such as offices and retail outlets.
Easy to Maintain With a removable intake grille, the cassette range can be kept clean and maintained easily, while louvres can be wiped down to remove any dust for a cleaner air flow.
22 1-20 202 H eat Pu m ps
*6 year warranty applies when the unit is installed by a Fujitsu Accredited Installer (residential installation only). Register your warranty easily online at: fujitsugeneral.co.nz/help-centre/warranty-registration
*Compact, non-intrusive grille design of 620x620mm is applicable only to the R32 Compact Cassette.
Remote heating and cooling control. Anytime, anywhere by smartphone or tablet.
anywAiR technology Wi-Fi adaptor
• A discreet solution that is easily installed by a Fujitsu Accredited Installer • Plugs easily into a select range of compatible Fujitsu General heat pumps / air conditioners • Enables easy to operate Wi-Fi control via the myanywAiR app. • Scenarios and timers can be pre-programmed
NEW & IMPROVED
Compact Cassette
R32 Indoor unit
Compact 4-Way Flow • Improved efficiency • High energy saving
AUTH09/12/18KVLA
• Compact design of grille
AR-REJ1E
Wireless RC
• Quiet operation • 2-stage Turbo Fan
Outdoor units
Optional controllers
UTY-FGAN1
anywAiR® technology Wi-Fi adaptor
IS-IR-WIFI-FG
UTY-RNRYT5
anywAiR® technology Wi-Fi device
LCD Touch Panel Controller
UTY-RSRYT
LCD Simple Controller with Operation mode
UTY-RHRYT
LCD Simple Controller without Operation mode
AOTH09/12KBTA
AOTH18KBTA
Product specifications: Set Code Model No.
SET-AUTH09KVLA
SET-AUTH12KVLA
SET-AUTH18KVLA
Indoor Unit
AUTH09KVLA
AUTH12KVLA
AUTH18KVLA
Outdoor Unit
AOTH09KBTA
AOTH12KBTA
AOTH18KBTA
Grille
UTG-UFYF-W
UTG-UFYF-W
UTG-UFYF-W
V / Ph / Hz
240 / 1 / 50
240 / 1 / 50
240 / 1 / 50
kW
2.5 (0.9-3.6)
3.5 (0.9-4.1)
5.0 (0.9-5.9)
Heating
kW
3.2 (0.9-4.5)
4.0 (0.9-5.1)
6.0 (0.9-7.1)
Cooling
kW
0.56
0.90
1.45
Heating
kW
0.76
1.04
1.71
Cooling
kW / kW
4.46
3.89
3.45
Power Source
Cooling
Capacity Input Power EER
Heating
kW / kW
4.21
3.85
3.51
TCSPF
COP
Residential: Hot / Average / Cold
kW / kW
5.804 / 5.126 / 5.179
5.206 / 4.740 / 4.862
4.666 / 4.325 / 4.474
HSPF
Residential: Hot / Average / Cold
kW / kW
5.064 / 4.575 / 4.108
4.822 / 4.268 / 3.714
4.574 / 3.954 / 3.376
Cooling / Heating
amps
3.0 / 4.0
4.2 / 5.0
6.2 / 7.3
l / hr
0.7
1.2
dBA
33 / 28
dBA
34 / 27
dBA
41 / 46
Running Current Moisture Removal
Noise Level
Indoor Sound Cooling Pressure Heating (High/Quiet) Outdoor Sound Pressure Cooling / Heating Outdoor Sound Power
Air Circulation (Indoor - High Fan) Cooling / Heating Indoor Unit Net Dimensions HxWxD
Outdoor Unit
37 / 28 47 / 48
2.3 38 / 26 43 / 30 48 / 49
dBA
59
61
62
l / sec
150 / 150
169 / 169
189 / 189
mm
245 x 570 x 570
245 x 570 x 570
245 x 570 x 570
kgs
15
15
15
mm
542 x 799 x 290
542 x 799 x 290
632 x 799 x 290
kgs
32
32
36
mm
49 x 620 x 620
49 x 620 x 620
49 x 620 x 620
Piping Connections (Liquid / Suction)
mm
Ø6.35 / Ø9.52
Ø6.35 / Ø9.52
Ø6.35 / Ø12.57
Max Pipe Length (Precharged Length)
m
20 (15)
20 (15)
30 (20)
Max Height Difference
m
15
15
20
Cooling
°CDB
-10 to 46
-10 to 46
-10 to 46
Heating
°CDB
-15 to 24
-15 to 24
-15 to 24
R32
R32
R32
Cassette Grille
Operation Range
Refrigerant
For more product information, please visit fujitsugeneral.co.nz. Due to ongoing research and development, specifications and designs are subject to improvement without notice therefore relevant manuals must be consulted before any action is taken to install or service these products. All capacity and energy efficiency ratings are based on the 2019 GEMS ≤65kw determination. Running current is at rated conditions (AS/NZS 3823) and does not include compressor start-up or variations in power supply and load conditions.
High Capacity Cassette
R32 Indoor unit
Circular Flow • Unique Circular Flow design via multi-directional 360° airflow • Consistent and even temperature
AUTG30/36/45/54KRLA
AR-WEC1E
Standard Controller
• Energy efficient Human Sensor mode
Optional controllers
UTY-FGAN1
anywAiR® technology Wi-Fi adaptor
UTY-RSRYT
LCD Simple Controller with Operation mode
IS-IR-WIFI-FG
anywAiR® technology Wi-Fi device
UTY-RHRYT
LCD Simple Controller without Operation mode
UTY-RNRYT5
Outdoor units
LCD Touch Panel Controller
UTY-LBTYC
Infa-Red Controller
AOTG30KBTA
AOTG36/45KBTA
AOTG54KBTA
Product specifications: Set Code Model No.
SET-AUTG30KRLA
SET-AUTG36KRLA
SET-AUTG45KRLA
SET-AUTG54KRLA
Indoor Unit
AUTG30KRLA
AUTG36KRLA
AUTG45KRLA
AUTG54KRLA
Cassette Grille
UTG-UKTA-W
UTG-UKTA-W
UTG-UKTA-W
UTG-UKTA-W
Outdoor Unit
AOTG30KBTA
AOTG36KBTA
AOTG45KBTA
AOTG54KBTA
Reverse Cycle
Reverse Cycle
Reverse Cycle
Reverse Cycle
240 / 1 / 50
240 / 1 / 50
240 / 1 / 50
240 / 1 / 50
Operation Type Power Source
V / Ph / Hz
Capacity
Cooling
kW
8.50 (2.80-10.00)
10.00 (2.80-11.20)
12.50 (4.00-14.00)
13.00 (4.50-14.50)
Heating
kW
10.00 (2.70-11.20)
11.20 (2.70-12.70)
14.00 (4.20-16.20)
16.00 (4.70-16.50)
Cooling (Max)
kW
2.39 (Max 4.04)
2.67 (Max 4.43)
3.89 (Max 4.87)
4.04 (Max 4.87)
Heating (Max)
kW
2.62 (Max 4.04)
2.48 (Max 4.43)
3.44 (Max 4.87)
4.23 (Max 4.87)
EER
Cooling
kW / kW
3.55
3.75
3.21
3.22
COP
Heating
kW / kW
3.81
4.52
4.07
3.78
TCSPF
Hot / Average / Cold
5.077 / 5.168 / 5.514
5.134 / 5.197 / 5.525
4.794 / 4.928 / 5.289
4.796 / 4.928 / 5.289
Input Power
HSPF
Hot / Average / Cold
5.066 / 4.629 / 4.041
5.199 / 4.879 / 4.318
4.963 / 4.494 / 3.728
4.707 / 4.092 / 3.556
amps
10.0 / 11.0
11.2 / 10.4
16.3 / 14.4
16.9 / 17.8
l / hr
2.5
3.5
4.5
5.0
Indoor Sound Pressure (High / Quiet)
dBA
40 / 33
43 / 34
44 / 35
45 / 36
Outdoor Sound Pressure
dBA
53
54
54
54
Outdoor Sound Power
dBA
68
67
68
68
Running Current
Cooling / Heating
Moisture Removal Noise Level
Air Circulation (Indoor - High Fan) Cooling / Heating Indoor Unit Net Dimensions HxWxD
Cassette Grille Outdoor Unit
l / sec
444
500
528
542
mm
288 x 840 x 840
288 x 840 x 840
288 x 840 x 840
288 x 840 x 840
kgs
27.5
30
30
30
mm
53 x 950 x 950
50 x 950 x 950
53 x 950 x 950
50 x 950 x 950
kgs
6
6
6
5.5
mm
830 x 900 x 330
914 x 970 x 370
914 x 970 x 370
1,290 x 900 x 330
kgs
61
75
75
87
Piping Connections (Liquid / Suction)
mm
Ø9.52 / Ø15.88
Ø9.52 / Ø15.88
Ø9.52 / Ø15.88
Ø9.52 / Ø15.88
Max Pipe Length (Precharged Length)
m
75 (20)
75 (30)
75 (30)
75 (30)
Max Height Difference
m
30
30
30
30
Cooling
°CDB
-15 to 46
-15 to 46
-15 to 46
-15 to 46
Heating
°CDB
-20 to 24
-20 to 24
-20 to 24
-20 to 24
R32
R32
R32
R32
Operation Range
Refrigerant
For more product information, please visit fujitsugeneral.co.nz. Due to ongoing research and development, specifications and designs are subject to improvement without notice therefore relevant manuals must be consulted before any action is taken to install or service these products. All capacity and energy efficiency ratings are based on the 2019 GEMS ≤65kw determination. Running current is at rated conditions (AS/NZS 3823) and does not include compressor start-up or variations in power supply and load conditions.
UTY-XWZX
UTY-XWZXZ5
External Connect Kit
UTD-ECS5A
High Capacity Cassette (3 PHASE)
For Outdoor unit
UTY-XWZXZ2
UTY-XWZXZ3
UTY-XWZXZ4
4-Way Flow
Function list
For Outdoor unit
For Indoor unit UTY-XWZX
●
Control Peak cut Low noise Priority Emergency stop Operation status Error status Fresh air control Auxiliary heater Preparation
Input
Output
UTY-XWZXZ5
UTD-ECS5A
●
●
UTY-XWZXZ2
UTY-XWZXZ3
—
—
— ● with • H—igh Efficiency Turbo Fan — — ● — — 3-dimensional blade —
— — — —
—
●
—
●
1
●*2
—
● ● ● ● ● ●
—
●
● ●* • Quiet Operation — ●
— — — —
● ●
— — —
2
AUTG54LRLA
— — —
●* • C—an be installed up to a height of 4.2m
* 1 : Duct type does not have this function. * 2 : Cassette and Ceiling type does not have this function.
Indoor unit
AR-WAF1E
Standard Controller
Controllers For Individual & Centralised Control Wired Remote Controller
Wired Remote Controller
UTY-RVNYN
Simple Remote Controller
UTY-RNNYN
Remote Temperature Sensor New amenity space can be offered by installing the Remote sensor.
UTY-RSNYN
Optional controllers IR Receiver Kit
Outdoor units
IR Receiver Kit
For Duct type
For Cassette type
+ UTY-XSZX / UTD-RS1OO
Communication Kit
For Compact Wall Mounted type
IS-IR-WIFI-FG
IS-RC-WIFI-1 UTY-LRHYM
anywAiR® Intesis AC technology Cloud Kit Auto Louver Grille Wi-Fi device Wi-Fi adaptor
UTY-RVNYN
LCD Backlit Controller
UTY-RSNYN
Simple Wired Controller
UTY-LRHYA2 UTY-LRHYA2
Infa-Red Controller
AOTG54LATT (3 Phase)
Product specifications: UTY-TWBXF Set Code
UTD-GXSA SET-AUTG54LRLA UTD-GXSB AUTG54LRLA
Indoor Unit Model No.
Cassette Grille
UTG-UGYA-W
Outdoor Unit
AOTG54LATT
Operation Type Power Source
Reverse Cycle
V / Ph / Hz
Capacity
415 / 3 / 50
Cooling
kW
14.00 (5.40-16.00)
Heating
kW
16.00 (5.60-18.00)
Cooling (Max)
kW
4.36 (Max 6.72)
Heating (Max)
kW
4.43 (Max 6.72)
EER
Cooling
kW / kW
3.21
COP
Heating
kW / kW
TCSPF
Hot / Average / Cold
Input Power
HSPF
Hot / Average / Cold
Running Current
Cooling / Heating
Moisture Removal Noise Level
3.61 4.708 / 4.775 / 5.093 4.505 / 4.082 / 3.413
amps
6.2 / 6.3
l / hr
5
Indoor Sound Pressure (High / Quiet)
dBA
47 / 37
Outdoor Sound Pressure
dBA
56
Outdoor Sound Power
dBA
70
l / sec
556
mm
288 x 840 x 840
Air Circulation (Indoor - High Fan) Cooling / Heating Indoor Unit Net Dimensions HxWxD
Cassette Grille Outdoor Unit
kgs
26
mm
50 x 950 x 950
kgs
5.5
mm
1290 x 900 x 330
kgs
104
mm
Ø9.52 / Ø15.88
Max Pipe Length (Precharged Length)
m
75 (30)
Max Height Difference
m
30
Cooling
°CDB
-15 to 46
Heating
°CDB
-15 to 24
Piping Connections (Liquid / Suction)
Operation Range
Refrigerant
R410A
For more product information, please visit fujitsugeneral.co.nz. Due to ongoing research and development, specifications and designs are subject to improvement without notice therefore relevant manuals must be consulted before any action is taken to install or service these products. All capacity and energy efficiency ratings are based on the 2019 GEMS ≤65kw determination. Running current is at rated conditions (AS/NZS 3823) and does not include compressor start-up or variations in power supply and load conditions.
FUJITSU GENERAL NEW ZEALAND A SUBSIDIARY OF FUJITSU GENERAL LIMITED
fujitsugeneral.co.nz 04 568 876 contact@fujitsugeneral.co.nz Fujitsu General accepts no liability for incorrect data. Please ensure you have confirmed installation requirements and pipe sizes prior to install. FGNZCR08/22