Salice Wind

Page 1

WIND

1


Salice Wind

Wind is characterised by compactness and elegant design. Combining the highest levels of performance with smooth and perfectly controlled movement, Wind is small, unobtrusive and elegantly designed. This compact lift system has strong functional appeal and takes up a minimum of valuable storage space. Wind is versatile and suitable for a vast range of furniture applications: office furniture, kitchens, bathrooms, living and bedroom furniture. With an optional carrier, Wind can be used in corner cabinets and for doors of large weight and dimensions. This system incorporates a soft close mechanism for decelerated closing or the Push self-opening system for handle-less doors. Wind is available in two attractive finishes.

2


Salice Wind How to order

• Determine door height, width & weight • Use the selection tables (pages 12-14) to ascertain which spring strength you require for your application • Some applications, such as large doors will require additional mechanisms. See page 8

Soft Close Mechanisms • Sold per door set • Mechanism only - see below for covers • Select spring strength based on the tables on pages 12-14 Part No. SAL.WDSC1W

Strength Code W

Spring Colour 1 x White

SAL.WDSC1Y

D

1 x Yellow

SAL.WDSCY.FG

I

2 x Yellow

SAL.WDSCB.FG

F

2 x Black

SAL.WDSCR.FG

S

2 x Red

Push-to-Open Mechanisms • Sold per door set • Mechanism only - see below for covers • Select spring strength based on the tables on pages 12-14 • Use with Salice magnetic push catch - see page 15

Part No. SAL.WDPO1W

Strength Code W

Spring Colour 1 x White

SAL.WDPO1Y

D

1 x Yellow

SAL.WDPOY.FG

I

2 x Yellow

SAL.WDPOB.FG

F

2 x Black

SAL.WDPOR.FG

S

2 x Red

Covers • Supplied with matching cover caps

Part No. SAL.WDCV.MBL.FG

Finish White

SAL.WDCV.WH.FG

Matt black

3


Salice Wind Technical Information

Flap door lift system fixed to the cabinet sides. • • • • •

Drilling of the door ø35. 13 mm deep cup. 85° opening with stop device (premounted). 94° opening without stop device. Possible drilling distance on the door (K): from 3 to 7 mm.

Drilling Patterns

ø 35 Top 13

33

17.5 + K

46

ø5x13

K 3÷7

1045

5

18

177 Internal cabinet side

24

D

8.5+D

19+D

8.5

19

21

ø5x13

Space needed to open the door A min. D1

57 85° D1

K 202

K 3 4 5 6 7

4

D1 = 16 = 17 = 18 = 19 = 20

K=3 K=4 K=5 K=6 K=7

T= A=min A=min A=min A=min A=min

16 0 0 0 0 0

17 0.1 0.1 0.1 0.1 0.1

18 0.1 0.1 0.1 0.1 0.1

T

19 02 02 02 02 02

20 0.2 0.2 0.2 0.2 0.2

21 0.3 0.3 0.3 0.3 0.3

22 0.5 0.4 0.4 0.4 0.4

23 0.6 0.6 0.6 0.6 0.6

24 0.7 0.7 0.7 0.7 0.7

25 0.9 0.9 0.9 0.9 0.8

26 1.1 1.1 1.1 1.1 1.0

27 1.8 1.3 1.3 1.2 1.2

28 2.7 2.1 1.5 1.5 1.4


Salice Wind Assembly Instructions

Fixing the plates to the cabinet sides

Left

Right

Left

Right

Deploying the system to the cups • This operation is tool free

Left

Right

Left

Right

Fixing the cups to the door

Installing the system to the plates. • Insert the system until back fixing is engaged. • This operation is tool free.

5


Salice Wind Installing the Covers

WARNING! Security cable ties. Remove the cable ties only at the end of the assembly. Use the instructions and the QR Code attached to the systems.

Installing the covers

Adjustments 1. Adjustment of the spring strength. 85° 2. Adjustment of the decelerating effect. 3. Extension/adjustment 85° of the opening angle of the door.

4. Height adjustment of the door from - 2 to +2. 5. Sideways adjustment of the door from - 2 to+2. 6. Depth adjustment of the door from - 1 to +3.

85° 85° device With stop (premounted) With stop device (premounted)

94°

3

2

3 1

2

1

94° device Without stop

Without stop device 94° 94°

4 4 6 5 5

6

6


Salice Wind Disassembly Instructions

Removal of the covers

Disassembly of the system. • Press the back lever and pull out the system. • This operation is tool free.

Unfasten the system from the cups. • Disconnecting the system from the cups. • This operation is tool free.

7


Salice Wind Extra Bracket

• Extra bracket to be used in conjunction with standard Salice Wind system when fixing to the top of a cabinet • Can also be used to allow the installation of additional systems on very large doors • Supplied in a set of 2 brackets with covers • Mechanisms must be ordered separately. Part No. SAL.WDSBK.WH

Finish White

SAL.WDSBK.MBL

Matt black

Drilling Patterns

ø 35 Top 13 17.5 + K K 3÷7

24

21 32

32

32

32

40

ø5x13

Space needed to open the door A min. D1

D1

85°

K T

K 3 4 5 6 7

8

= = = = =

D1 13 14 15 16 17

K=3 K=4 K=5 K=6 K=7

T= A=min A=min A=min A=min A=min

16 0 0 0 0 0

17 0.1 0.1 0.1 0.1 0.1

18 0.1 0.1 0.1 0.1 0.1

19 02 02 02 02 02

20 0.2 0.2 0.2 0.2 0.2

21 0.3 0.3 0.3 0.3 0.3

22 0.5 0.4 0.4 0.4 0.4

23 0.6 0.6 0.6 0.6 0.6

24 0.7 0.7 0.7 0.7 0.7

25 0.9 0.9 0.9 0.9 0.8

26 1.1 1.1 1.1 1.0 1.0

27 1.8 1.3 1.3 1.2 1.2

28 2.7 2.1 1.5 1.5 1.4


Salice Wind Examples of applications for top-hung doors using optional carrier

For cabinets that require a third system

D1

K

3

36

49 K 3 4 5 6 7

= = = = =

D1 13 14 15 16 17

18

55

104

For corner cabinets

D1

K 3 4 5 6 7

K

= = = = =

D1 13 14 15 16 17

9


Salice Wind Assembly instructions for carriers

10

Fixing the carriers to the top of the cabinet.

Fixing the carriers to the top of the cabinet.

Installing the system to the plates. • Installing the system till the back fixing. • This operation is tool free.

Installing the covers


Salice Wind Disassembly instructions for carriers

Removal of the covers

Dissassembly of the system • Press the back lever and pull out the system. • This operation is tool free.

Unfasten the plates from the carriers

Unfasten the carriers

11


Salice Wind Charts

Determine which system to use for a particular door size and weight. For doors with larger weight and dimensions, it is possible to use more than two systems on the same door. These systems can be fixed to intermediate sides or, if not possible, by using the optional carrier for the plate (page 8). In this case please carefully check the chart concerning the door overlay on top of the cabinet (D1). We recommend that all applications are verified by a practical trial.

6 0.8 0.6

Door weight (Kg)

0.4

5

0.2 0.8 0.6 0.4

4 0.8

0.2

0.6 0.4

3

0.2 0.8 0.6 0.4

2

0.2 0.8 0.6 0.4 0.2

1

220

280

320

360

400

440

480

520

480

520

Door height (mm)

8 0.8 0.6 0.4

7

0.2 0.8 0.6

Door weight (Kg)

0.4

6 0.8

0.2

0.6 0.4

5

0.2 0.8 0.6 0.4

4 0.8

0.2

0.6 0.4

3

0.2 0.8 0.6 0.4

2

0.2 0.8 0.6 0.4

1

0.2

220

280

320

360

400

440

Door height (mm)

12

560

600


Salice Wind Charts 15

0.8 0.6 0.4

14

0.2 0.8 0.6 0.4

13

0.2 0.8 0.6 0.4

12

0.2 0.8 0.6 0.4

11

0.2 0.8 0.6

Door weight (Kg)

0.4

10

0.2 0.8 0.6 0.4

9 0.8

0.2

0.6 0.4

8 0.8

0.2

0.6 0.4

7

0.2

4 WIND

0.8 0.6 0.4

6 0.8

0.2

3 WIND

0.6 0.4

5

0.2 0.8 0.6 0.4

4 0.8

0.2

2 WIND

0.6 0.4

3

0.2 0.8 0.6 0.4 0.2

2

320

360

400

440

480

520

560

600

Door height (mm) 20 0.8 0.6 0.4

19

0.2 0.8 0.6 0.4

18

0.2 0.8 0.6 0.4

17

0.2 0.8 0.6 0.4

16

0.2 0.8 0.6 0.4

15

0.2 0.8 0.6 0.4

14

0.2 0.8

Door weight (Kg)

0.6 0.4

13

0.2 0.8 0.6 0.4

12

0.2 0.8 0.6 0.4

11

0.2

4 WIND

0.8 0.6 0.4

10

0.2 0.8 0.6 0.4

9 0.8

3 WIND

0.2

0.6 0.4

8 0.8

0.2

0.6 0.4

7

0.2 0.8 0.6

2 WIND

0.4

6 0.8

0.2

0.6 0.4

5

0.2 0.8 0.6 0.4

4

0.2

320

360

400

440

480

520

Door height (mm)

560

600

13


Salice Wind Charts

24

0.8 0.6 0.4

23

0.2 0.8 0.6 0.4

22

0.2 0.8 0.6 0.4

21

0.2 0.8 0.6 0.4

20 0.8

0.2

0.6 0.4

19

0.2 0.8 0.6 0.4

18

0.2 0.8 0.6 0.4

Door weight (Kg)

17

0.2 0.8 0.6 0.4

16

0.2 0.8 0.6 0.4

15

0.2 0.8 0.6 0.4

14

0.2

4 WIND

0.8 0.6 0.4

13

0.2 0.8 0.6 0.4

12

0.2 0.8

3 WIND

0.6 0.4

11

0.2 0.8 0.6 0.4

10

0.2 0.8 0.6 0.4

9 0.8

0.2

0.6

2 WIND

0.4

8 0.8

0.2

0.6 0.4

7

0.2 0.8 0.6 0.4

6

0.2

320

360

400

440

480

520

Door height (mm)

14

560

600


Salice Wind Magnetic Push

• Magnetic push catch for use with Salice Push-to-open systems including Salice Wind • To achieve best results use both magnetic catch and adjustable retaining catch • Catch: Ø10mm x 40mm long • Retaining Catch: Ø15mm x 11mm long Part No. SAL.DPMSNG

Finish Grey

Description Catch

SAL.DP39XXG

Grey

Retaining Catch

ø10 S

Application of the standard magnetic catch Drill a hole Ø 10 mm and min. 40 mm depth in the top, the side or the base panel of the cabinet.

40 min

Insert the release device into the hole. 2.5 T

Inserting the adjustable magnetic catch When using the magnetic catch and release latch

ø 10

together, the holding strength of the door against the cabinet is considerably increased (30%), helping to avoid

S

accidental opening. Installation requires a drilled hole Ø15mm and 11mm deep. Depth adjustment from -0.5 mm to +2.5 mm.

40 min

2.5 T

ø 15

ø 16.6

9.5 ø 15

ø 16.6

15


Salice Wind Push Application

For cabinets over 400mm high, it is suggested SAL.DP39XXG

that one release device is used.

SAL.DPMSNG

For cabinets less than 400mm high, it is suggested that two release devices are used.

SAL.DP39XXG

SAL.DPMSNG SAL.DPMSNG 16


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.