Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Page 1

Corporate Sales

Birmingham

Bristol

Tel: 0870 3000 070 Fax: 0870 3000 080

Tel: 0121 741 2800 Fax: 0121 741 2801

Tel: 01454 202050 Fax: 01454 202900

Leeds

Manchester

Scotland

Tel: 0870 3300 347 Fax: 0870 3300 348

Tel: 0161 866 6060 Fax: 0161 866 6081

Tel: 01506 444960 Fax: 01506 444961

London North Region

London Central Region

London South Region

Tel: 01707 282480 Fax: 01707 282481

Tel: 0207 928 6810 Fax: 0207 928 6569

Tel: 01689 881030 Fax: 01689 881031

Ireland Tel: +353 (0)1 419 8800 Fax: +353 (0)1 419 8890 email: sales@meir.mee.com

2011 Air Conditioning Product Catalogue

Sales Offices:

The Renewable Solutions Provider

Making a World of Difference 2011 Air Conditioning Product Catalogue

After Sales Service: 0161 866 6089 email: air.conditioning@meuk.mee.com web: www.mitsubishielectric.co.uk/aircon UNITED KINGDOM Mitsubishi Electric Europe Living Environmental Systems Division Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, England General Enquiries Telephone: 01707 282880 Fax: 01707 278881 IRELAND Mitsubishi Electric Europe Westgate Business Park, Ballymount, Dublin 24, Ireland Telephone: Dublin (01) 419 8800 Fax: Dublin (01) 419 8890 International code: (003531) Country of origin: United Kingdom – Japan – Thailand – Malaysia. ©Mitsubishi Electric Europe 2011. Mitsubishi and Mitsubishi Electric are trademarks of Mitsubishi Electric Europe B.V. The company reserves the right to make any variation in technical specification to the equipment described, or to withdraw or replace products without prior notification or public announcement. Mitsubishi Electric is constantly developing and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. All goods are supplied subject to the Company’s General Conditions of Sale, a copy of which is available on request. Third-party product and brand names may be trademarks or registered trademarks of their respective owners.

Printed in November 2010

Features Key

SAP No. 237005

Air Conditioning Designed by Square Bear Limited 01604 899099. Square Bear Limited are committed to using FSC certified paper and printers, wherever possible. The sealant process used on this catalogue is environmentally friendly, recyclable and biodegradable.

Domestic Heating

Commercial Heating Photovoltaics


Swing Vane Mode Auto Vane Shutter - when unit is switched off the vane automatically closes Wide Swing - distributes air laterally by up to 150º Long Airflow Mode - particularly suitable for use in long, narrow spaces Infra-red remote controller Optimised rotary or scroll compressor Econo Cool - allows set temperature to be raised by 2ºC without any loss of comfort and a 20% gain in energy efficiency Inverter control - adjusts performance to economically match the demand for heating or cooling Auto-Restart Quiet operation

the name Mitsubishi is synonymous with excellence Known the world over, Mitsubishi is a trusted global leader associated with a variety of products and services. Founded in 1921, Mitsubishi Electric quickly rose to the forefront of the air conditioning industry - a position we still enjoy today.

Mitsubishi Electric Partner Programme Open to all contractors - large or small - the Mitsubishi Electric Partner Programme offers contractors a totally new and unique set of benefits. There are two categories within the programme - Accredited Installer and Business Solutions Partner. These levels are a straight-forward reflection of the Partner’s stage of growth. All customers signing up to the programme standards are committing to continued training and professional development.

For more information please contact your local sales office

72 different airflow patterns - 2, 3 or 4 way discharge High ceiling compatibility through wide flow air outlets Auto-Changeover Hot Start - draught prevention Factory charged refrigerant up to 30m Standard filter

Unsurpassed air conditioning from Mitsubishi Electric Air conditioning is an ideal way of controlling the internal environment of any building, large or small. It does not only provide cooling when required, but also heating and often hot water can be supplied from the same system. Providing heating and hot water as part of an integrated air conditioning system is far more efficient than traditional heating methods such as gas and as a result reduced running costs and emissions can be realised. More and more people are experiencing the benefits of comfortable working, living and leisure environments made possible with air conditioning. As market leaders, we pride ourselves in providing high performance, competitive systems with low running costs and emissions.

Optional high efficiency filter Catechin filter - improves air quality and prevents the spread of bacteria and viruses within the room

Environmental Awareness

Air Cleaning filter - catches dust particles and contaminates, helping to keep the air fresh

Mitsubishi Electric boasts an explicit commitment to sustainable business practices such as energy and resource efficiency, minimising ecological impacts and reducing greenhouse gas emissions. All of our factories and UK operations are ISO14001 registered, the international standard that ensures that we are fully aware of the environmental impact of all our processes and ensures we have procedures in place to reduce them. However, we have gone far further than any accepted minimum standards. Our ‘Environmental Vision 2021’ provides a vision for a lower emission future that influences all our policy decisions. Our Green Gateway Initiative takes this vision even further as it looks to install behavioural change in our own operations and our wider sphere of influence with contractors, consultants and end users. It looks to highlight the advantages and opportunities provided, by ensuring all of our activities are undertaken with consideration to the environment. We are also proud to be a partner within Sustainable Energy Europe, whose stated aim is to raise awareness of energy use in Europe.

Anti-Allergy Enzyme filter - artificial enzyme catalyst on the filament catches allergens Nano Platinum filter - incorporates nanometre sized platinum-ceramic particles that generate stable antibacterial and deodourising effects Plasma Duo filter system Quick clean design Drain lift pump as standard Optional drain lift pump Low unit height - minimal intrusion into occupied space High external static pressure Optional high static fan motor Fresh air knockout Branch duct knockout Double thermostat function - control the temp via a sensor in the controller or the unit (wired remote controllers only) Ceiling soiling prevention Replace Technology available Refrigerant volume check function I-See Sensor Duty Standby Operation I-Save - Recalls the preferred (preset) temperature via a single button

Mitsubishi Electric Training Options Mitsubishi Electric has four state-of-the-art training suites based at different locations around the country for your convenience. Providing training for all levels of expertise, our courses are taught by experienced engineers, with a wealth of knowledge and are all CPD accredited.

For bookings please telephone 0161 866 6089

Many of our systems have an energy label of A. These systems meet the criteria of the Energy Technology List and hence could qualify for 100% first year enhanced capital allowances (whole system cost and ‘reasonable’ cost of installation). For further information please go to www.eca.gov.uk

The Forest Stewardship Council (FSC) is an international network promoting responsible management of the world's forest. The paper this catalogue is printed on supports the development of responsible forest management worldwide. The wood comes from FSC certified, well managed forests, company controlled sources and/or recycled material.

Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB. Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB. UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. UK Conditions: Winter; indoor 21˚C DB; outdoor -1˚C WB.

www.green-gateway.co.uk www.sustenergy.org www.mitsubishielectric.com/eco

Note: The fuse rating is only a typical value, it is the responsibility of a qualified electrician/electrical engineer to select the correct cable size and fuse rating based on current regulation and site specific conditions.


The Mitsubishi Electric Air Conditioning Product Catalogue The new 2011 catalogue offers you more information than ever before. That’s because the Mitsubishi Electric air conditioning range contains many new models, plus a fully comprehensive selection of control options to choose from.

If there is anything not covered in the catalogue and you want to know more, simply contact your Mitsubishi Electric supplier who will be delighted to help you. Alternatively, you can visit our website at www.mitsubishielectric.co.uk/aircon for further information.

In addition to increasing the range, we’ve also tried to help you find what you need more quickly and efficiently. We hope you will find it an interesting and informative read.

Contents Page 13 - 62 Page 63 - 131 Page 133 - 243 Page 245 - 264 Page 265 - 307

Page 1


M Series & Mr Slim Split-System Air Conditioning

Air Conditioning Commercial Heating Domestic Heating Photovoltaics


Mitsubishi Electric Split-Systems M Series and Mr Slim

Energy Saving: Reduced Power Consumption & Increased Efficiency

Mitsubishi Electric’s M Series and Mr Slim range of split-systems have benefited from massive investment year on year, the overall result being a vastly improved and more flexible collection of split-systems. One of the most important features of the inverter controlled range is the adoption of A Control, allowing the standardisation of the M Series and Mr Slim ranges, as well as strengthening the remote controller functionality. As a result of this it is possible to connect Mr Slim indoor units to MXZ Multi-Split outdoor units, allowing for complete design flexibility. The Mr Slim Standard Inverter models have further increased the range, offering a lower cost option, whilst still incorporating Mitsubishi Electric’s energy saving inverter technology. These models are now also available as a 3-phase option. A Control is Mitsubishi Electric’s control mechanism for providing standard remote controller functions alongside system diagnostics, fault code monitoring and the ability to interface with the MELANS (Mitsubishi Electric Air Conditioning Network Solution) equipment such as the AG150 Centralised Controller, TG2000, Modbus, Trend, LonWorks® & BACnet® etc.

The entire R410A M Series and Mr Slim ranges are inverter controlled Inverter technology saves energy for two main reasons: 1. The compressor varies its speed to match the cooling or heating load and therefore consumes only the power necessary to match the exact requirement of the room. 2. When an inverter driven air conditioner is operating at partial load, the energy efficiency of the system is significantly higher than at full load. In a typical application, partial load conditions prevail for more than 90% of operation time. A fixed speed system can only operate at 100% capacity and cannot match the annual efficiencies of an inverter system.

The adoption of this technology as standard by Mitsubishi Electric shows our commitment to both increasing your savings, as well as protecting the global environment. Page 4

Page 5


Energy Saving Technology

Total Energy Conservation

Reduced Power Consumption & Increased Efficiency Application of new technologies in Mitsubishi Electric inverter systems significantly enhance the generic benefits of inverter driven systems.

Reluctance DC Rotary Compressors The centralised winding DC motor uses less copper wiring than a conventional version and features a high density, centralised winding method that raises motor winding efficiency to 96%. Units incorporating this motor also benefit from a low starting current as well as a stable set point.

Joint Lap DC Motor This unique “Poki Poki” motor is manufactured using a joint lapping technique. This reliable motor operates based on a high density, high magnetic force, making it extremely efficient.

Highly Efficient Scroll Compressors The scroll compressor is equipped with a ‘Frame Compliance Mechanism’ that allows movement in the axial direction of the frame supporting the moving scroll. This construction realises up to a 27% improvement in compressor efficiency by reducing both leakage and friction losses.

DC Fan Motor A high-efficiency DC motor drives the fan of the outdoor units. It offers up to 60% greater efficiency than an equivalent AC motor.

Simple Partial Switching Method, PAM Control Compared to the conventional active filter method, the simple partial method PAM (Pulse Amplitude Modulation) control found on the new models helps to reduce energy losses. When combined with the Vector-Wave Eco Inverter, PAM control also allows for greater power and efficiency.

Power Receiver and Twin LEV Control Mitsubishi Electric has developed a power receiver and twin LEVs (linear expansion valves) that optimise the performance of the compressor. By ensuring optimum control in response to the operating waveform and outdoor temperature, this technology is tailored to the characteristics of the R410A refrigerant to enhance operating efficiency.

Normal Inver ter vs. PAM

Heat exchanger

PAM adjusts the form of the current wave so that it is close to that of the supply voltage wave. High harmonics are reduced and 98% of the electricity is utilised.

Vector-Wave Eco Inverter This technology uses a specially designed microprocessor to produce the most efficient waveform in response to varying compressor motor rpm. By improving operating efficiency from low to high speeds, annual electricity costs are reduced.

Page 6

Compressor

Power receiver LEV 1

Heat exchanger LEV 2

Page 7


Re-use of Existing Pipework Upgrading Existing R22 & R407c Systems In general the upgrading of existing R22 systems to modern efficient R410A systems has been a difficult or expensive option. This is because the existing pipework would either have to be replaced, or cleaned with dedicated specialist equipment. These actions were necessary as the chlorine residue from R22 system pipework caused chemical reactions with the lubricating oils used in HFC compressors, the result being poor performance and system failure.

Reduced Installation Time & Cost

Mitsubishi Electric’s *1

Replace Technology The M Series*2 & Mr Slim ranges incorporate ‘Replace Technology’ to allow the upgrade of systems using existing pipe work, without the need to apply any special cleaning machines. M Series, S Series, Power Inverter (35/50) and Standard Inverter (100/125/140) utilise Ether oil or the Mitsubishi Electric patented Hard Alkyl Benzene (HAB) oil, a unique oil that is more tolerant of contamination. By combining these oils with developments in oil separator technology it is possible for these models to use existing pipework without any special operations. All other Mr Slim models use a friction reduction “Heat Caulking” method, whereby friction inside the scroll compressor is reduced by coating the edge of the blade, thereby suppressing the increase in temperature that causes refrigerant oil deterioration. *1 Assuming existing pipework is suitable for R410A operational pressures *2 Not available on the MXZ-8B140VA and MXZ-8B160YA Multi-Split outdoor units

The Advantages of Replace Technology For Tenants and Owners Reduces installation time causing less disruption of business Saves on installation costs

For Installers Installation time is reduced significantly It is not necessary to purchase new piping for R410A refrigerant Time-consuming pipe cleaning is not necessary when employing Replace Technology

Page 8

Page 9


Split-System Product Range Overview Outdoor Units

0.9kW Cooling Capacity M Series Inverter (Multi-Split)

M Series Inverter

M Series Inverter

M Series Inverter Multi-Split

M Series Inverter Multi-Split

M Series Inverter Multi-Split

M Series Power Multi

Mr Slim Standard Inverter

Mr Slim Standard Inverter

Mr Slim Power Inverter

Mr Slim Power Inverter

Mr Slim Power Inverter

MUZ-GE25-35VA MUZ-FD25-35VABH SUZ-KA25/35VA2 MXZ-2C52VA

MUZ-GE50VA SUZ-KA50-60VA2

MUZ-GE60-71VA SUZ-KA71VA2

MXZ-3C54VA MXZ-4C71VA

MXZ-4C80VA MXZ-5C100VA

MXZ-6C120VA

MXZ-8B140VA MXZ-8B160YA

PUHZ-P100V/YHA(3)

PUHZ-P125-250V/YHA(3)

PUHZ-RP35/50VHA4

PUHZ-RP60/71VHA4

PUHZ-RP100-250V/YKA

M Series Inverter

MUZ-HC25-35VA(B)

44kW Cooling Capacity Mr Slim Zubadan Inverter

PUHZ-HRP71-125V/YHA2

Indoor Units Model / Size

22 (2.2kW) Multi-Split only

25 (2.5kW)

35 (3.5kW)

50 (5.0kW)

60 (6.0kW)

71 (7.1kW)

100 (10.0kW)

125 (12.5kW)

140 (14.0kW)

200 (19.0kW)

250 (22.0kW)

400 (38.0kW)

500 (44.0kW)

MSZ-HC-VA(B) MSZ-GE-VA MSZ-FD-VA PKA-RP-HAL/KAL MFZ-KA-VA SEZ-KD-VAQ PEAD-RP-JAQ PEA-RP-GAQ SLZ-KA-VAQ PLA-RP-BA(2)(3) PCA-RP-KAQ PCA-RP-HAQ PSA-RP-GA

Page 10

Page 11


The Adaptable Split-System Range

Designed to fit anywhere Available in a variety of options, our Split-System range fits in wherever it’s needed. Indoor units can be four way blow cassettes, ducted, wall, floor or ceiling mounted. Up to eight indoor units can then be connected to a single outdoor unit providing the ideal air conditioning solution.

Simple technology at its best Many of our systems have an energy label of A, are registered on the Energy Technology List and hence qualify for 100% first year enhanced capital allowances (whole system cost and ‘reasonable’ cost of installation). For further information please go to

www.eca.gov.uk

Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB. Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB. UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. UK Conditions: Winter; indoor 21˚C DB; outdoor -1˚C WB.

Page 12


M Series Room Air Conditioning

Air Conditioning Commercial Heating Domestic Heating Photovoltaics


The M Series Range Perfect for Small to Medium Sized Applications Designed to heat or cool small to medium sized applications, the M Series range provides a versatile, yet affordable air conditioning solution. Quick to install and also one of the quietest units on the market (as low as 19dBA*1), this newly designed, attractive range offers the perfect way to ensure a comfortable environment with the minimum of disruption.

Designed to Fit Anywhere

Flexible enough to suit a range of applications, the M Series range includes models that will run up to eight indoor units per outdoor unit. With vastly increased pipe length and height differences over its R407c predecessors, the M Series range is extremely versatile, helping to make system application easier. This diagram shows how a typical multi-split system could be installed into a medium sized office for example.

Surprisingly affordable, the efficiency of the M Series range presents substantial savings in heating mode, when compared with more conventional heating systems. Additional features such as ‘Econo-Cool’ allow airflow to be precisely directed towards users, allowing set temperatures to be raised by 2ºC with no loss in comfort and a 20% gain in energy efficiency.

Highly Energy Efficient The entire M Series range is now available using inverter technology. By matching the compressor speed to the cooling or heating load of the room, up to a 30% reduction in power consumption can be achieved when compared to direct on line models. Increasingly aware of the importance of protecting the environment, the M Series range is made as small as possible to reduce raw material use and the emissions generated in distribution. The whole range also has a very high recovery rate when recycled, so that materials can be used again at the end of the systems life. Many models also make use of a new air filtering system containing the compound Catechin, which helps to improve air quality and prevent the spread of bacteria and viruses. M Series offers the end user some of the highest energy efficiency ratings available, alongside greater application flexibility. Lower running costs and reduced CO2 emissions throughout the life of the system, along with increased comfort for consumers are virtually guaranteed and Mitsubishi Electric has made M Series the natural choice for today’s small to medium sized application market. *1 MSZ-GE22-35VA

Page 14

Page 15


Clean, Comfor table Environment Catechin Filter Catechin is a bioflavonoid that is found in green tea. Bioflavonoids are a group of chemical substances present in many plants, that have both antiviral and antioxidant qualities. In addition to these benefits, Catechin also offers excellent deodorising characteristics; which is why Mitsubishi Electric uses this compound in its air conditioning filters to not only improve air quality, but to also prevent the spread of bacteria and viruses within a room. The filter can be easily removed and when washed regularly, deodorising effectiveness should last for more than 10 years. MSZ-GE22-50VA / MSZ-HC wall mounted and MFZ floor mounted systems are supplied with or have the option of the Catechin filter.

Operating Status Monitoring

“Anti-Allergy Enzyme Filter” mechanism

Monitor lamps located on the right of the indoor unit provide at-a-glance recognition of the air conditioner operating status. When the difference between the set temperature and room temperature is more than 2°C, both monitor lamps will turn on. If it is less than 2°C, only the upper lamp will light.

I Artificial enzyme catalysts on the filament catch the allergens. I The artificial enzyme catalyst helps the chemical reaction with Oxygen and severs the S-S bonds.*1 I Proteins with severed S-S bonds are no longer allergen proteins.

Silent Operation Technological improvements reducing operating sound levels

Only

19dBA in

Quick Clean Design The vane on the MSZ-GE and MSZ-FD wall mounted models easily detaches, allowing access to the louvres. These can then be opened outwards (without any special tools) for quick cleaning of the heat exchanger, fan and air vents. Regular cleaning will increase both operating efficiency and energy-savings.

‘silent mode’

Quick Clean Design can reduce your electricity bill by approximately 30%

Unlike conventional models with a grilled air intake, wall mounted models feature a smoothly contoured, flat panel finish with a top air intake that not only improves aesthetics, but also helps to reduce noise as the heat exchanger area is fully covered. In fact, noise level during normal operation is only 19dBA for the MSZ-GE22-35VA in ‘silent mode’, making it one of the quietest indoor units on the market. This is as a result of the multi-angled heat exchanger having a modified fin shape that reduces air resistance, producing a smoother, quieter flow of air. Alongside this, the wide diameter of the fan produces greater airflow at lower fan speeds and the uneven pitch between each fan blade helps to eliminate unwanted noise. *1 Mites and other allergen protein consist of sulfur atoms (S) that have bonded together.

Page 16

Heat Exchanger

Fan

Electricity bill increases by 5%*1

Electricity bill increases by 25%*1

Air Vent

*1 Electricity bill comparison of operation under a fixed temperature with 8g of soil on the fan and also without.

Page 17


The MSZ-FD Series The "I-See Sensor" automatically moves from side to side, monitoring floor temperature over a wide area of 150°.

The FD Series line-up is engineered for high energy efficiency and low sound levels. The I-See Sensor, Plasma-Duo filter system and other superb functions raise the comfort evel to even greater heights.

Conventional air conditioners control indoor temperature by using only the temperature of the intake air at the top of the room. As a result, the floor level temperature, which exerts such a crucial impact on the temperature that people feel, tends to be overlooked. The I-See Sensor detects the floor temperatures to ensure constant comfort in the living areas.

High Energy Efficiency

Cold air tends to sink to floor level, which is often the cause of over cooling. The I-See Sensor tracks this floor level temperature and adjusts the air outlet temperature accordingly.

With the latest inverter technology, energy efficiency is improved by about 20%. Specifically, more than 5.0 is attained for both the COP and EER for a size 25.

Warm air tends to rise up from the floor level, which often prevents that zone from warming up. The I-See Sensor tracks this floor level temperature and adjusts the air outlet flow accordingly.

Besides a pre-filter, the MSZ-FD is also fitted with two plasma air-purifying functions. These functions are engineered to change air dirt particles from micron to nano-size in scale.

Powerful Heating Capacity The VABH outdoor unit is engineered for use in cold regions (down to -25ºC ambient) and is equipped with a powerful compressor, enabling an improvement in heating capacity. The heating power is raised by about 30% over the standard model and keeps the room comfortable even on cold days.

Plasma Electrode Unit

Field Test Result: Size 35. Sweden, 23rd January 2008

A plasma electrode unit is mounted inside the air conditioner. Electro-discharge is used to generate ozone & plasma. The collaboration between ozone & plasma and two special filters creates a dynamic plasma air cleaning function.

Plasma Air Purification

Plasma Deodorisation

The “Anti-allergen electric enzyme filter” uses the power of the static electricity charged in the filter, as well as plasma generated in the plasma electrode unit to capture the bacteria, pollen and other allergens in the air, which are then neutralised by the enzyme in the filter.

The “Platinum catalyst deodorising filter” captures small foul-smelling substances in the air, then breaks down the source of the odours with the power of the ozone generated in the plasma electrode unit and the platinum catalyst contained in the filter.

Quiet Running A larger line flow fan is included in the FD model. This allows stable capacity with fewer rotations, reducing operating noise.

MSZ-FD Size 25 Size 35

Cooling Heating Cooling Heating

20dBA 20dBA 21dBA 21dBA

Side view of

MSZ-FD Ø106

Page 18

The MSZ-FD is equipped with a “Mould Fighter” function designed to suppress the growth of spores of mould. The ozone generated in the plasma electrode unit attacks the mould spores, reducing mould growth by about 20%. Mould Fighter mechanism Step 1

Step 2

After cooling operation the Plasma Electrode unit fills the inside of the indoor unit with ozone (O3).

The heat exchanger is dried for about 40 mins by the fan mode operation.

Page 19


MXZ Multi-Split Systems The MXZ-8B Power Multi Inver ter Heat Pump Multi-Split Outdoor Units Ideal for apartments or small commercial buildings I

14kW and 15.5kW Inverter Multi Systems, based on Mr Slim Power Inverter technology

I

Ability to connect up to eight indoor units across the M Series and Mr Slim product range within a maximum capacity index of 20.2kW

I

Total Pipe Length of 115m / Height Difference of 30m

I

Single and 3 phase power supplies available

I

Connection of indoor units is through either a 3-way (PAC-AK31BC) or 5-way (PAC-AK52BC) branch box, either singularly or with two in combination

I

Individual control of each indoor unit is now possible (ON/OFF and Setpoint)

I

Low starting and running currents

I

Connection to M-NET system via MAC-399IF interface (one per indoor unit needed)

All Mitsubishi Electric MXZ multi-split outdoor models have an energy label of ‘A’

Example of a Power Multi system using eight indoor units Branch Box

Branch Box

Outdoor Unit

Page 20

Page 21


Excellent Features Available in wall and floor mounted, the M Series range is quiet, economic to run and easy to install. The outdoor units can run up to eight indoor units, all controlled with a simple remote controller. Whatever your requirements may be, Mitsubishi Electric offers the perfect air conditioning solution for any situation.

Contents 24

MSZ-HC-VA(B) Inverter Heat Pump, Wall Mounted System

26

MSZ-GE-VA Inverter Heat Pump, Wall Mounted System

28

MSZ-FD-VA Inverter Heat Pump, Wall Mounted System

30

MFZ-KA-VA Inverter Heat Pump, Floor Mounted System

32

MXZ-C-VA Multi-Split Inverter Heat Pump

34

MXZ-8B-VA/YA Power Multi Inverter Heat Pump

60

Outdoor Units

62

M Series Accessories / Optional Extras

Simple technology at its best Many of our systems have an energy label of A, are registered on the Energy Technology List and hence qualify for 100% first year enhanced capital allowances (whole system cost and ‘reasonable’ cost of installation). For further information please go to

www.eca.gov.uk

Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB. Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB. UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. UK Conditions: Winter; indoor 21˚C DB; outdoor -1˚C WB.

Page 22

Page 23


Dimensions

INDOOR UNIT MSZ-HC25/35VA(B)

Classic Wall Mounted System Mitsubishi Electric’s range of high specification, flat panel wall mounted models make use of inverter technology, whilst providing extremely good value for money, costing approximately 20% less than the MSZ-G equivalent.

Upper View

>

These units have extremely quiet sound levels, whilst also delivering economical air conditioning, with improved COP/EER figures and in many cases corresponding ‘A’ rated energy labels.

Front View

>

Side View

M Series Range

MSZ-HC-VA(B) Inverter Heat Pump

>

* Catechin filter is optional

Technical Information MODEL REFERENCE CAPACITY (kW)

MSZ-HC25VA

MSZ-HC35VAB

Heating (nominal)

3.2 (0.9-4.4)

3.6 (0.9-4.8)

Cooling (nominal)

2.5 (0.9-3.0)

3.4 (1.0-3.7)

Heating (UK)

2.65 (0.75-3.65)

3.0 (0.75-4.0)

Cooling (UK)

2.5 (0.9-3.0)

3.35 (1.0-3.65)

SHF (nominal & UK)

0.79

0.76

COP / EER (nominal)

3.64 / 3.25

3.62 / 3.01

ENERGY LABEL

Heating/Cooling

AIRFLOW (m3/min)

Heating/Cooling - Lo-Mi-Hi-SupHi

PIPE SIZE mm(in) NOISE (dBA) DIMENSIONS (mm)

A /A

A/B

5.1-6.5-7.8-9.1 / 5.3-7.0-8.7-10.5

4.9-6.7-8.0-9.2 / 5.2-6.8-8.4-10.2

Gas

9.52(3/8”)

9.52(3/8”)

Liquid

6.35(1/4”)

6.35(1/4”)

26-32-38-43 / 26-32-38-43

26-32-38-43 / 26-32-38-43

Heating/Cooling - Lo-Mi-Hi-SupHi Width

788

788

Depth

225

225

Height

295

295

WEIGHT (kg)

9

9

Fed by Outdoor Unit

Fed by Outdoor Unit

PHASE

Single

Single

RUNNING CURRENT (A)

0.22

0.22

FUSE RATING (BS88) - HRC (A)

6

6

INTERCONNECTING CABLE No. CORES

4

4

ELECTRICAL SUPPLY

MSZ-HC-VA(B) Inverter Heat Pump

MSZ-HC-VA(B) - INDOOR UNITS

MUZ-HC-VA(B) - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)

Heating/Cooling

WEIGHT (kg) DIMENSIONS (mm)

MUZ-HC25VA

MUZ-HC35VAB

47 / 46

48 / 47

25

25

Width

684

684

Depth

255

255

Height

540

540

220-240v, 50Hz

220-240v, 50Hz

ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A)

Single

Single

0.88 / 0.77

0.995 / 1.13

0.801 / 0.616

0.905 / 0.904

4.2

5.3

4.2 / 3.7 [5.5]

4.8 / 5.3 [6.5]

FUSE RATING (BS88) - HRC (A)

10

10

MAINS CABLE No. CORES

3

3

MAX PIPE LENGTH (m)

10

10

SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 7m

Page 24

5

5

0.73

0.75

Page 25


Dimensions

INDOOR UNIT MSZ-GE22-50VA

Wall Mounted System The MSZ series has been completely redesigned and features the new Nano Platinum filter system.

Upper View

>

These models offer industry leading noise levels as low as 19dBA and have a distinctively styled front panel that not only looks appealing, but also helps to make cleaning of the unit easier.

Front View

Side View

>

Side View

>

M Series Range

MSZ-GE-VA Inverter Heat Pump

>

* Wide swing & long airflow mode available for MSZ-GE60/71VA * The anti-allergy enzyme filter is optional * Nano Platinum filter available for MSZ-GE60/71VA, Catechin filter available for MSZ-GE22-50VA

Technical Information MSZ-GE-VA - INDOOR UNITS MODEL REFERENCE

MSZ-GE22VA

MSZ-GE25VA

MSZ-GE35VA

MSZ-GE50VA

MSZ-GE60VA

MSZ-GE71VA

Heating (nominal)

3.3 (0.9-4.0)

3.2 (1.3-4.5)

4.0 (1.6-5.3)

5.8 (1.4-7.3)

6.8 (2.0-9.3)

8.1 (2.2-9.9)

Cooling (nominal)

2.2 (0.9-3.0)

2.5 (1.1-3.5)

3.5 (1.1-4.0)

5.0 (1.4-5.5)

6.0 (1.5-7.5)

7.1 (2.4-8.7)

Heating (UK)

2.75 (0.75-3.3)

2.65 (1.1-3.75)

3.3 (1.35-4.4)

4.8 (1.15-6.05)

5.65 (1.65-7.75)

6.75 (1.85-8.25)

Cooling (UK)

7.05 (2.4-8.65)

2.2 (0.9-3.0)

2.5 (1.1-3.45)

3.45 (1.1-3.95)

4.95 (1.4-5.45)

5.95 (1.5-7.45)

SHF (nominal & UK)

-

0.96

0.82

0.76

0.79

0.78

COP / EER (nominal)

-

4.57 / 4.59

4.19 / 4.05

3.71 / 3.30

3.84 / 3.40

3.83 / 3.33

-

A /A

A /A

A /A

A /A

A /A

ENERGY LABEL

Heating/Cooling

AIRFLOW (m3/min)

Heating - Sil-Lo-Mi-Hi-SupHi-SupHiLP

4.1-4.6-6.6-9.1-11.5 4.1-4.8-6.6-9.1-11.5

4.1-4.8-6.7-9.1-11.5 6.5-7.8-9.6-12.2-14.5 9.8-11.3-13.4-15.6-18.3-20.7 10.2-11.5-13.3-15.4-17.8-19.4

Cooling - Sil-Lo-Mi-Hi-SupHi-SupHiLP

4.1-4.6-6.7-9.2-11.3 4.1-4.8-6.7-9.1-11.3

4.1-4.8-6.7-9.1-12.7 6.5-7.8-9.6-11.9-15.1 9.8-11.3-13.4-15.6-18.3-20.7 9.7-11.5-13.3-15.4-17.8-19.4

NOISE (dBA)

DIMENSIONS (mm)

Gas

9.52 (3/8”)

9.52 (3/8”)

9.52 (3/8”)

12.7 (1/2”)

15.88 (5/8”)

15.88 (5/8”)

Liquid

6.35 (1/4”)

6.35 (1/4”)

6.35 (1/4”)

6.35 (1/4”)

6.35 (1/4”)

9.52 (3/8”)

Heating - Sil-Lo-Mi-Hi-SupHi-SupHiLP

19-21-29-36-42

19-21-29-36-42

19-22-30-36-42

28-33-37-43-48

29-37-41-45-49-52

30-37-41-45-49-52

Cooling - Sil-Lo-Mi-Hi-SupHi-SupHiLP

19-21-29-36-42

19-21-29-36-42

19-22-30-36-43

28-33-38-44-49

29-37-41-45-49-52

30-37-41-45-49-53

Width

798

798

798

798

1100

1100

Depth

232

232

232

232

238

238

Height

295

295

295

295

325

325

10

10

10

10

16

16

WEIGHT (kg)

INDOOR UNIT MSZ-GE60/71VA

Upper View

> 1100 1090

5

Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit

ELECTRICAL SUPPLY

Single

Single

Single

Single

Single

Single

FUSE RATING (BS88) – HRC (A)

6

6

6

6

6

6

INTERCONNECTING CABLE No. CORES

4

4

4

4

4

4

N/A Multi-Split Only

MUZ-GE25VA

MUZ-GE35VA

MUZ-GE50VA

MUZ-GE60VA

MUZ-GE71VA

-

48 / 47

48 / 47

56 / 54

55 / 55

55 / 55

PHASE

MUZ-GE-VA - OUTDOOR UNITS

DIMENSIONS (mm)

-

30

33

54

50

53

Width

-

800

800

840

840

840

Depth

-

285

285

330

330

330

Height

-

550

550

850

880

880

-

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz

-

0.70 / 0.545

0.955 / 0.865

1.565 / 1.515

1.77 / 1.76

2.11 / 2.13

-

0.637 / 0.436

0.869 / 0.692

1.424 / 1.212

1.611 / 1.408

1.92 / 1.704

ELECTRICAL SUPPLY SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A)

-

3.7

4.6

7.0

7.9

9.4

SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

-

3.7 / 2.9 [7.4]

4.6 / 4.2 [8.6]

7.0 / 6.8 [13]

7.9 / 7.8 [14.5]

9.4 / 9.3 [16.6]

FUSE RATING (BS88) – HRC (A)

-

10

10

16

16

20

MAINS CABLE No. CORES

-

3

3

3

3

3

MAX PIPE LENGTH (m)

-

20

20

30

30

30

MAX HEIGHT DIFFERENCE (m)

-

12

12

15

15

15

CHARGE R410A (kg) - 7m

-

0.8

1.15

1.55

1.55

1.9

Page 26

Front View

>

238 Air in 5

67

WEIGHT (kg)

12

Heating/Cooling

76

843

181

100

NOISE (dBA)

325

MODEL REFERENCE

MSZ-GE-VA Inverter Heat Pump

PIPE SIZE mm(in)

65 ( 70∞)

Air out

3

CAPACITY (kW)

125 160 184

Page 27


Dimensions

INDOOR UNIT MSZ-FD25/35VA

Wall Mounted System

Upper View

The MSZ-FD series is our most energy efficient M Series wall mounted unit to date. These high COP models feature the new Plasma Duo filter system. They also offer industry leading noise levels and have a distinctively styled front panel that not only looks appealing but also helps to make cleaning of the unit easier.

>

Also incorporated is an ‘I-See Sensor’, providing even temperature distribution and further reducing energy consumption.

Front View

>

Side View

M Series Range

MSZ-FD-VA Inverter Heat Pump

>

Technical Information MODEL REFERENCE CAPACITY (kW)

MSZ-FD25VA

MSZ-FD35VA

Heating (nominal)

3.2 (1.5-6.3)

4.0 (1.3-6.6)

Cooling (nominal)

2.5 (1.1-3.5)

3.5 (0.8-4.0)

Heating (UK)

2.65 (1.25-5.25)

3.3 (1.1-5.5)

Cooling (UK)

2.5 (1.1-3.45)

3.45 (0.8-3.95)

SHF (nominal & UK)

0.85

0.85

COP / EER (nominal)

5.33 / 5.15

4.76 / 4.19

A /A

A /A

4.5-6.7-9.2-12.1 / 4.6-6.3-8.6-11.2

4.7-6.7-9.2-12.5 / 4.6-6.3-8.6-11.2

Gas

9.52 (3/8”)

9.52 (3/8”)

Liquid

6.35 (1/4”)

6.35 (1/4”)

20-29-36-43 / 20-29-36-42

21-29-36-44 / 21-29-36-43

ENERGY LABEL

Heating/Cooling

AIRFLOW (m3/min)

Heating/Cooling - Lo-Mi-Hi-SupHi

PIPE SIZE mm(in)

NOISE (dBA) DIMENSIONS (mm)

Heating/Cooling - Lo-Mi-Hi-SupHi Width

798

798

Depth

257

257

Height

295

295

WEIGHT (kg) ELECTRICAL SUPPLY

12

12

Fed by Outdoor Unit

Fed by Outdoor Unit

Single

Single

FUSE RATING (BS88) – HRC (A)

6

6

INTERCONNECTING CABLE No. CORES

4

4

PHASE

MSZ-FD-VA Inverter Heat Pump

MSZ-FD-VA - INDOOR UNITS

MUZ-FD-VABH - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)

Heating/Cooling

WEIGHT (kg) DIMENSIONS (mm)

MUZ-FD25VABH

MUZ-FD35VABH

46 / 46

50 / 47

36

36

Width

800

800

Depth

285

285

Height

550

550

220-240v, 50Hz

220-240v, 50Hz

ELECTRICAL SUPPLY SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A)

0.60 / 0.485

0.84 / 0.835

0.546 / 0.388

0.764 / 0.668

2.9

3.9

2.9 / 2.4 [10]

3.9 / 3.8 [10.5]

FUSE RATING (BS88) – HRC (A)

10

16

MAINS CABLE No. CORES

3

3

MAX PIPE LENGTH (m)

20

20

SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 7m

Page 28

12

12

1.15

1.15

Page 29


Dimensions INDOOR UNIT MFZ-KA25-50VA

Floor Mounted System The MFZ-KA-VA series is extremely versatile and is designed for wall attached installation at floor level. The auto swing vane provides a more natural and comfortable airflow throughout the room and the lightweight, compact design makes installation easy.

* The anti-allergy enzyme filter is optional

Upper View

>

Front View

>

M Series Range

MFZ-KA-VA Inverter Heat Pump

Technical Information

MFZ-KA-VA - INDOOR UNITS CAPACITY (kW)

MFZ-KA25VA

MFZ-KA35VA

MFZ-KA50VA

Heating (nominal)

3.4 (0.9-5.1)

4.0 (0.9-6.2)

6.0 (0.9-7.9)

Cooling (nominal)

2.5 (0.9-3.4)

3.5 (0.9-3.9)

4.8 (0.9-5.4)

Heating (UK)

2.85 (0.75-4.25)

3.3 (0.75-5.15)

5.0 (0.75-6.55)

Cooling (UK)

4.75 (0.9-5.35)

2.5 (0.9-3.35)

3.45 (0.9-3.85)

SHF (nominal & UK)

0.66

0.65

0.63

COP / EER (nominal)

4.07 / 4.31

3.64 / 3.21

3.23 / 3.10

ENERGY LABEL

Heating/Cooling

AIRFLOW (m3/min)

Heating/Cooling - Lo-Mi-Hi-SupHi

PIPE SIZE mm(in)

NOISE (dBA) DIMENSIONS (mm)

A /A

A /A

C/B

5.0-6.2-7.6-9.4 / 4.8-5.8-7.1-8.9

5.2-6.2-7.8-9.5 / 5.0-6.1-7.4-9.1

7.4-8.8-9.8-12.3 / 7.1-7.9-9.2-11.2

Gas

9.52 (3/8”)

9.52 (3/8”)

12.7 (1/2”)

Liquid

6.35 (1/4”)

6.35 (1/4”)

6.35 (1/4”)

22-27-32-37 / 22-27-32-37

25-28-33-38 / 23-28-33-38

32-35-39-44 / 32-35-39-43

Heating/Cooling - Lo-Mi-Hi-SupHi Width

700

700

700

Depth

200

200

200

Height

600

600

600

14

14

14

Fed by Outdoor Unit

Fed by Outdoor Unit

Fed by Outdoor Unit

Single

Single

Single

FUSE RATING (BS88) – HRC (A)

6

6

6

INTERCONNECTING CABLE No. CORES

4

4

4

SUZ-KA25VA2

SUZ-KA35VA2

SUZ-KA50VA2

46 / 46

48 / 47

55 / 53

33

37

53

Width

800

800

840

Depth

285

285

330

Height

550

550

850

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz

0.835 / 0.58

1.10 / 1.09

1.86 / 1.55

0.76 / 0.46

1.00 / 0.87

1.69 / 1.24

3.65

4.75

6.75

3.85 / 3.25 [8.4]

4.95 / 4.75 [9.4]

6.55 / 6.95 [16.2]

FUSE RATING (BS88) - HRC (A)

10

10

20

MAINS CABLE No. CORES

3

3

3

MAX PIPE LENGTH (m)

20

20

30

WEIGHT (kg) ELECTRICAL SUPPLY PHASE

Side View

> MFZ-KA-VA Inverter Heat Pump

MODEL REFERENCE

SUZ-KA-VA2 - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)

Heating/Cooling

WEIGHT (kg) DIMENSIONS (mm)

ELECTRICAL SUPPLY SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

MAX HEIGHT DIFFERENCE (m)

12

12

15

CHARGE R410A (kg) - 7m

0.8

1.05

1.6

Page 30

Page 31


OUTDOOR UNIT MXZ-2C52VA

Multi-Split Units

Upper View

>

Front View

>

Side View

>

>

Side View

>

The multi-split system allows up to six M Series or Mr Slim wall mounted, cassette, ducted, floor or ceiling mounted indoor unit heat pumps of different capacities to be operated from a single outdoor unit. This makes it an economic answer in multi-room applications, whilst also offering space saving benefits.

OUTDOOR UNIT MXZ-3C54VA / MXZ-4C71VA

MXZ-6C120VA

2

2-3

2-4

2-4

2-5

2-6

6.4 (1.0-7.0)

7.0 (2.6-9.0)

8.6 (3.4-10.7)

9.4 (3.4-11.6)

12.0 (4.1-14.0)

14.0 (3.5-16.5)

Cooling (nominal)

5.2 (1.1-6.0)

5.4 (2.9-6.8)

7.1 (3.7-8.8)

8.0 (3.7-9.2)

10.0 (3.9-11.0)

12.0 (3.5-13.5)

Heating (UK)

5.3 (0.85-5.8)

5.8 (2.15-7.5)

7.15 (2.85-8.9)

7.8 (2.85-9.65)

9.95 (3.4-11.65)

11.65 (2.9-13.7)

Cooling (UK)

5.15 (1.1-5.95)

5.35 (2.9-6.75)

7.05 (3.65-8.75)

7.95 (3.65-9.15)

9.9 (3.85-10.9)

11.9 (3.45-13.4)

COP / EER (nominal)

Outdoor Only

3.98 / 4.00

5.04 / 4.23

4.78 / 4.54

4.87 / 4.09

4.23 / 3.57

3.88 / 3.21

ENERGy LABEL

Heating/Cooling

A /A

A /A

A /A

A /A

A /A

A /A

MAX AIRFLOW (m3/min)

Heating/Cooling

NOISE (dBA)

Heating/Cooling - Sil-Hi

DIMENSIONS (mm)

33.3 / 32.9

43 / 42.1

43 / 42.1

43.8 / 42.2

59.3 / 56.6

59.5 / 69.9

49-50 / 46-49

48-51 / 45-47

48-52 / 45-48

46-48 / 44-46

47-54 / 46-51

53-57 / 51-55

Width

800

840

840

900

900

900

Depth

285

330

330

320

320

320

Height

550

710

710

900

900

1070

WEIGHT (kg)

38

57

58

67

68

88

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz

Heating/Cooling (nominal)

1.61 / 1.30

1.465 / 1.19

1.705 / 1.68

1.93 / 1.955

2.835 / 2.88

3.47 / 3.61

Heating/Cooling (UK)

1.47 / 1.04

1.33 / 0.95

1.55 / 1.34

1.76 / 1.56

2.58 / 2.30

3.16 / 2.89

7.22

6.43

7.49

8.59

12.45

15.85

7.22 / 5.83 [10.2]

6.43 / 5.23 [15]

7.49 / 7.38 [15]

8.48 / 8.59 [17.4]

12.45 / 12.30 [18.4]

15.24 / 15.85 [27]

ELECTRICAL SUPPLy POWER INPUT (kW)

STARTING CURRENT (A) RUNNING CURRENT (A) [MAX] Heating/Cooling INTERCONNECTING CABLE No. CORES

4 Core

4 Core

4 Core

4 Core

4 Core

4 Core

TOTAL PIPE LENGTH (m)

30

50

60

70

80

80

MAX PIPE LENGTH PER INDOOR UNIT (m)

20

25

25

25

25

25

15 (10 if OU higher than IU)

15 (10 if OU higher than IU)

15 (10 if OU higher than IU)

15 (10 if OU higher than IU)

15 (10 if OU higher than IU)

15 (10 if OU higher than IU)

1.3 [20m]

2.7 [40m]

2.7 [40m]

3.5 [40m]

4.0 [40m]

5.0 [60m]

16

25

25

25

25

40

MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) [Precharged Length] FUSE RATING (BS88) – HRC (A)

Page 32

17.7

240 710

315

440

45

360

84

250

500

Front View

900

Air in

Air out

Side View

>

200

270 Air in

> 30

320

10

Indoor and outdoor connect wiring (35 x 53) hole

E connection for MXZ-5B100VA

88 E unit connection D unit connection C unit connection B unit connection A unit connection

23

317

OUTDOOR UNIT MXZ-6C120VA Upper View

>

Front View

>

Side View

>

Page 33

MXZ-C-VA Multi-Split Inverter Heat Pump (5.2 -12kW )

MXZ-5C100VA

B unit connection

900

MXZ-4C80VA

C unit connection

23.1

405

MXZ-4C71VA

D unit connection

597

Heating (nominal)

MXZ-3C54VA

66.3

132

MXZ-2C52VA

NUMBER OF CONNECTABLE INDOOR UNITS

200 35

>

460

MODEL REFERENCE

Upper View

11

MXZ-C-VA - OUTDOOR UNITS

13

D connection for MXZ-4B71VA

45

*1 Combined max running current of all indoors on system must not exceed 3A if PEAD-RP is used

330

27.1 Indoor and outdoor connect wiring 39 x 27 hole

(Bolt pitch) 387

MXZ-6C120VA

30

OUTDOOR UNIT MXZ-4C80VA / MXZ-5C100VA

355

MXZ-5C100VA

30

200

299

24

MXZ-4C80VA

840

A unit connection

35

MXZ-4C71VA

Air out

74

MXZ-3C54VA

CAPACITy (kW)

13.3

Air in

WALL MOUNTED FLOOR MOUNTED DUCTED CEILING CASSETTE CEILING SUSPENDED MSZ-GE22/25/35VA SEZ-KD25/35VAQ MSZ-FD25/35VA MFZ-KA25/35VA SLZ-KA25/35VAQ MSZ-EF25/35VEB MSZ-GE22/25/35/50VA SLZ-KA25/35/50VAQ SEZ-KD25/35/50VAQ PCA-RP50KAQ MSZ-FD25/35VA MFZ-KA25/35/50VA PLA-RP50BA PEAD-RP50JAQ*1 MSZ-EF25/35/50VEB MSZ-GE22/25/35/50/60VA SEZ-KD25/35/50/60VAQ SLZ-KA25/35/50VAQ MFZ-KA25/35/50VA PCA-RP50/60KAQ MSZ-FD25/35VA PLA-RP50/60BA PEAD-RP50JAQ*1 MSZ-EF25/35/50VEB MSZ-GE22/25/35/50/60/71VA SEZ-KD25/35/50/60/71VAQ SLZ-KA25/35/50VAQ PCA-RP50/60/71KAQ MSZ-FD25/35VA MFZ-KA25/35/50VA PEAD-RP50/60/71JAQ*1 PLA-RP50/60/71BA(2) MSZ-EF25/35/50VEB MSZ-GE22/25/35/50/60/71VA SEZ-KD25/35/50/60/71VAQ SLZ-KA25/35/50VAQ MFZ-KA25/35/50VA MSZ-FD25/35VA PCA-RP50/60/71KAQ PEAD-RP50/60/71JAQ*1 PLA-RP50/60/71BA(2) MSZ-EF25/35/50VEB MSZ-GE22/25/35/50/60/71VA SEZ-KD25/35/50/60/71VAQ SLZ-KA25/35/50VAQ MFZ-KA25/35/50VA MSZ-FD25/35VA PCA-RP50/60/71KAQ PEAD-RP50/60/71JAQ*1 PLA-RP50/60/71BA(2) MSZ-EF25/35/50VEB

MXZ-2C52VA

Air in

20.3

MULTI-SPLIT - INDOOR UNITS MODEL REFERENCE

171

288

31.3

16.8

Technical Information

500 233.1

Front View

396

169 63.2

> 360.6 (Bolt Pitch)

Upper View

17.7

I

16

I

16

I

Up to six indoor units may be connected to a single outdoor unit Energy saving inverter controlled outdoor unit adjusts compressor performance to economically match the demand for heating and cooling Units may be added within the capacity of the system as requirements change Capacities of indoor units may be mixed to suit individual rooms New size 80, 100 and 120 have current limit adjustment for managing energy costs. They also feature a wiring/piping correction function to analyse the system for connection errors via the press of a single button

27

I

40

I

M Series Range

MXZ-C-VA Inverter Heat Pump (5.2 - 12kW)

Dimensions


OUTDOOR UNIT MXZ-8B140VA / MXZ-8B160YA

Inverter Heat Pump Multi-Split Units

Upper View

>

The Power Multi systems allow up to eight M Series or Mr Slim cassette, ducted, floor, ceiling or wall mounted indoor units of different capacities to be operated from a single outdoor unit, making use of two types of branch box to achieve this. This makes them an economic answer in multi-room applications and ideal for apartments or small commercial buildings. I

14 and 15.5kW Inverter Multi Systems, based on Mr Slim Power Inverter technology

I

Total Pipe length of 115m / Height difference of 30m

I

Individual control of each indoor unit is now possible (ON/OFF & Setpoint)

I

Low starting and running currents

I

Connection to M-NET system via MAC-399IF interface (one per indoor unit)

I

Current limit adjustment for managing energy costs

Front View

>

Side View

>

M Series Range

MXZ-8B-VA/YA Power Multi (14-15.5kW)

Dimensions

Technical Information MULTI-SPLIT - INDOOR UNITS WALL MOUNTED

FLOOR MOUNTED

DUCTED

CEILING CASSETTE

MXZ-8B140VA

MSZ-GE22/25/35/50/60/71VA MSZ-FD25/35VA MSZ-EF25/35/50VEB

MFZ-KA25/35/50VA

SEZ-KD25/35/50/60/71VAQ PEAD-RP50/60/71JAQ*1

SLZ-KA25/35/50VAQ PLA-RP35/50/60/71BA(2) PLA-RP100BA(3)*2

MXZ-8B160YA

MSZ-GE22/25/35/50/60/71VA MSZ-FD25/35VA MSZ-EF25/35/50VEB

MFZ-KA25/35/50VA

SEZ-KD25/35/50/60/71VAQ PEAD-RP50/60/71JAQ*1

SLZ-KA25/35/50VAQ PLA-RP35/50/60/71BA(2) PLA-RP100BA(3)*2

PAC-AK31BC - BRANCH BOX

POWER SUPPLY TO BRANCH BOX

15.5

POWER SUPPLY TO INDOOR UNITS

Heating (UK)

13.3

14.95

PIPE SIZE mm(in) Main Outdoor Side - Gas

Cooling (UK)

13.9

15.4

COP / EER (nominal)

Outdoor Only

3.91 / 3.52

3.61 / 3.21

ENERGY LABEL

Heating/Cooling

A /A

A /A

100

106

52 / 47-50

54 / 48-51

55

TOTAL PIPE LENGTH - Branch Boxes to Indoor Unit (m)

60

MAX HEIGHT DIFFERENCE - Outdoor Unit to Branch Box (m)

30

MAX HEIGHT DIFFERENCE - Branch Box to Indoor Unit (m)

15

DIMENSIONS (mm)

950

Width

450

330

Depth

280

Height

1350

1350

Height

198

129

139

220-240v, 50Hz

380-415v, 50Hz

Single

3

Heating/Cooling (nominal)

3.90 / 3.79

4.80 / 4.64

Heating/Cooling (UK)

3.55 / 3.03

4.37 / 3.71

14

7

17.05 / 16.55 [29.5]

7.00 / 6.77 [13]

4 Core

4 Core

115

115

15 (from Branch Box)

15 (from Branch Box)

70

70

RUNNING CURRENT (A) [MAX] Heating/Cooling INTERCONNECTING CABLE No. CORES TOTAL PIPE LENGTH (m) MAX PIPE LENGTH PER INDOOR UNIT (m) FURTHEST PIPE LENGTH - Outdoor to Indoor (m) MAX HEIGHT DIFFERENCE - Outdoor to Indoor (m)

30 (20 if OU lower than IU) 30 (20 if OU lower than IU)

BRANCH BOX PAC-AK52BC Front View

>

Side View

>

Upper View

>

320 450

PAC-AK52BC

91 73

55

95 61

280 79

50

39

34

to indoor unit

NUMBER OF CONNECTABLE INDOOR UNITS POWER SUPPLY TO BRANCH BOX POWER SUPPLY TO INDOOR UNITS

1-5 From Outdoor Unit From Branch Box

PIPE SIZE mm(in) Main Outdoor Side - Gas

15.88(5/8”)

PIPE SIZE mm(in) Main Outdoor Side - Liquid

9.52(3/8”)

MAX PIPE LENGTH - Outdoor Unit to Branch Box (m)

55

TOTAL PIPE LENGTH - Branch Boxes to Indoor Unit (m)

60

MAX HEIGHT DIFFERENCE - Outdoor Unit to Branch Box (m)

30

MAX HEIGHT DIFFERENCE - Branch Box to Indoor Unit (m)

15

DIMENSIONS (mm)

Width

450

MAX HEIGHT DIFFERENCE - Indoor to Indoor (m)

12

12

CHARGE R410A (kg) - 40m

8.5

8.5

Depth

280

FUSE RATING (BS88) – HRC (A)

40

25

Height

198

Page 34

21

25 75

12

PAC-AK52BC - BRANCH BOX MODEL REFERENCE

25 75

9.52(3/8”)

MAX PIPE LENGTH - Outdoor Unit to Branch Box (m)

330

STARTING CURRENT (A)

25

15.88(5/8”)

950

PHASE

70

From Branch Box

Width

ELECTRICAL SUPPLY

POWER INPUT (kW)

From Outdoor Unit

Depth

WEIGHT (kg)

A

B

E E

D

B

C C

D

A A

B

402

DIMENSIONS (mm)

Heating/Cooling - Sil-Hi

A

B

C C

25

25 75

25 75

25 75

25

21

75

24

NOISE (dBA)

PIPE SIZE mm(in) Main Outdoor Side - Liquid

1-3

12

Page 35

MXZ-8B-VA/YA Power Multi Inverter Heat Pump (14-15.5kW)

18.0

14.0

320

39

34

402

16.0

50

24

Heating (nominal) Cooling (nominal)

79

68

CAPACITY (kW)

PAC-AK31BC

NUMBER OF CONNECTABLE INDOOR UNITS

61

>

68

2-8

280

95

Upper View

39

2-8

65

NUMBER OF CONNECTABLE INDOOR UNITS

MODEL REFERENCE

198

MXZ-8B160YA

91 73

>

to indoor unit

39

MXZ-8B140VA

MAX AIRFLOW (m3/min)

450 205

65

MODEL REFERENCE

Side View

70

MXZ-8B-VA/YA - OUTDOOR UNITS

Can only be connected using a PAC-AK52BC with a PAC-AK52YP-E pipe

>

35

capacity of indoor units must not exceed 100% if PEAD-RP is used

*2

Front View

35

*1 Total

BRANCH BOX PAC-AK31BC

198

MODEL REFERENCE


Multi-Split Systems 8 Outdoor Units

32 Indoor Units MSZ-GE-VA Series

MXZ-2C52VA Inverter Multi unit MSZ-FD-VA Series

MXZ-6C120VA Inverter Multi unit

MFZ-KA-VA Series

MXZ-3C54VA MXZ-4C71VA Inverter Multi units

SEZ-KD-VAQ Series

MXZ-8B140VA MXZ-8B160YA Power Multi units

Multi-Split systems allow up to eight M Series or Mr Slim cassette, ducted, floor, ceiling or wall mounted indoor units of different capacities to be operated from a single outdoor unit.

PEAD-RP-JAQ Series

MXZ-4C80VA MXZ-5C100VA Inverter Multi units

SLZ-KA-VAQ Series

PLA-RP-BA(2)(3) Series

PCA-RP-KAQ Series

Page 36

Page 37


Multi-Split System Combinations 1 Outdoor Unit Indoor unit combination

1 Outdoor Unit

2 Indoor Units Cooling / Heating Capacity (kW) Unit A

+ + + + + +

22 25 35 25 35 35

2.20 2.20 1.93 2.50 2.13 2.60

/ / / / / /

3.05 2.90 2.43 3.15 2.63 3.20

2.20 2.50 3.07 2.50 2.98 2.60

/ / / / / /

3.05 3.30 3.87 3.15 3.68 3.20

Indoor unit combination

Up to 3 Indoor Units Cooling / Heating Capacity (kW) Unit A

Unit B

Unit C

1 ROOM 2.20 2.50 3.50 5.00

22 25 35 50

/ / / /

3.30 3.60 4.00 6.80

+ + + + + + + + + +

2.20 2.20 2.08 1.65 2.50 2.25 1.80 2.70 2.22 2.70

22 25 35 50 25 35 50 35 50 50

/ / / / / / / / / /

3.30 3.14 2.62 2.08 3.40 2.83 2.27 3.40 2.80 3.40

2.20 2.50 3.32 3.75 2.50 3.15 3.60 2.70 3.18 2.70

/ / / / / / / / / /

3.30 3.56 4.18 4.72 3.40 3.97 4.53 3.40 4.00 3.40

3 ROOMS 22 22 22 22 22 22 22 22 25 25 25 25

+ + + + + + + + + + + +

22 22 22 22 25 25 25 35 25 25 25 35

Page 38

+ + + + + + + + + + + +

22 25 35 50 25 35 50 35 25 35 50 35

Unit C

1.80 1.72 1.50 1.26 1.65 1.45 1.22 1.29 1.80 1.59 1.35 1.42

/ / / / / / / / / / / /

2.27 2.20 1.95 1.64 2.11 1.88 1.59 1.67 2.33 2.06 1.75 1.84

1.80 1.72 1.50 1.26 1.88 1.65 1.39 2.05 1.80 1.59 1.35 1.99

/ / / / / / / / / / / /

2.27 2.20 1.95 1.64 2.40 2.13 1.80 2.66 2.33 2.06 1.75 2.58

1.80 1.96 2.39 2.87 1.88 2.30 2.78 2.05 1.80 2.22 2.70 1.99

/ / / / / / / / / / / /

2.27 2.50 3.10 3.72 2.40 2.99 3.61 2.66 2.33 2.88 3.50 2.58

Unit A

Unit B

Unit C

Unit D

22 + 22 + 22 + 22

1.78 / 2.15

1.78 / 2.15

1.78 / 2.15

1.78 / 2.15

22 + 22 + 22 + 25

1.72 / 2.08

1.72 / 2.08

1.72 / 2.08

22 + 22 + 22 + 35

1.55 / 1.87

1.55 / 1.87

1.55 / 1.87

22 + 22 + 22 + 50

1.35 / 1.63

1.35 / 1.63

1.35 / 1.63

3.06 / 3.71

22 + 22 + 25 + 25

1.66 / 2.01

1.66 / 2.01

1.89 / 2.29

1.89 / 2.29

Unit D

22 + 22 + 25 + 35

1.50 / 1.82

1.50 / 1.82

1.71 / 2.07

2.39 / 2.89

22 + 22 + 25 + 50

1.31 / 1.59

1.31 / 1.59

1.49 / 1.81

2.98 / 3.61

Indoor unit combination

Cooling / Heating Capacity (kW) Unit A

Unit B

35 + 60

2.91 / 3.46

4.99 / 5.94

35 + 71

2.61 / 3.10

5.29 / 6.30

1.95 / 2.36

50 + 50

3.95 / 4.70

3.95 / 4.70

2.46 / 2.98

50 + 60

3.64 / 4.27

4.36 / 5.13

50 + 71

3.31 / 3.88

4.69 / 5.52

60 + 60

4.00 / 4.70

4.00 / 4.70

60 + 71

3.66 / 4.31

4.34 / 5.09

22 + 22 + 22

2.20 / 2.90

2.20 / 2.90

2.20 / 2.90

22 + 22 + 25

2.20 / 2.81

2.20 / 2.81

2.50 / 3.19

22 + 22 + 35

2.14 / 2.56

2.14 / 2.56

3.41 / 4.08

1.83 / 2.20

1.83 / 2.20

4.15 / 5.00

22

2.20 / 3.30

25

2.50 / 3.60

22 + 22 + 35 + 35

1.37 / 1.66

1.37 / 1.66

2.18 / 2.64

2.18 / 2.64

35

3.50 / 4.00

22 + 25 + 25 + 25

1.61 / 1.95

1.83 / 2.22

1.83 / 2.22

1.83 / 2.22

50

5.00 / 7.20

22 + 25 + 25 + 35

1.46 / 1.77

1.66 / 2.01

1.66 / 2.01

2.32 / 2.81

60

6.00 / 7.90

22 + 25 + 25 + 50

1.28 / 1.55

1.45 / 1.76

1.45 / 1.76

2.91 / 3.52

22 + 25 + 35 + 35

1.34 / 1.62

1.52 / 1.84

2.12 / 2.57

2.12 / 2.57

Unit C

22 + 22

2.20 / 3.30

2.20 / 3.30

25 + 25 + 25 + 25

1.78 / 2.15

1.78 / 2.15

1.78 / 2.15

1.78 / 2.15

22 + 25

2.20 / 3.23

2.50 / 3.67

25 + 25 + 25 + 35

1.61 / 1.95

1.61 / 1.95

1.61 / 1.95

2.26 / 2.74

22 + 22 + 60

1.67 / 1.99

1.67 / 1.99

4.56 / 5.42

22 + 35

2.20 / 2.97

3.50 / 4.73

25 + 25 + 25 + 50

1.42 / 1.72

1.42 / 1.72

1.42 / 1.72

2.84 / 3.44

22 + 22 + 71

1.53 / 1.80

1.53 / 1.80

4.94 / 5.80

22 + 50

2.08 / 2.63

4.72 / 5.97

25 + 25 + 35 + 35

1.48 / 1.79

1.48 / 1.79

2.07 / 2.51

2.07 / 2.51

22 + 25 + 25

2.20 / 2.72

2.50 / 3.09

2.50 / 3.09

22 + 60

1.82 / 2.31

4.98 / 6.29 22 + 25 + 35

2.07 / 2.50

2.35 / 2.84

3.29 / 3.97

25 + 25

2.50 / 3.60

2.50 / 3.60

25 + 35

2.50 / 3.29

3.50 / 4.61

22 + 25 + 50

1.79 / 2.13

2.04 / 2.42

4.07 / 4.85

25 + 50

2.27 / 2.87

4.53 / 5.73

22 + 25 + 60

1.64 / 1.93

1.87 / 2.20

4.49 / 5.27

25 + 60

2.00 / 2.53

4.80 / 6.07

22 + 25 + 71

1.49 / 1.75

1.69 / 1.99

4.81 / 5.66

35 + 35

3.40 / 4.30

3.40 / 4.30

22 + 35 + 35

1.87 / 2.25

2.97 / 3.58

2.97 / 3.58

22 + 35 + 50

1.64 / 1.93

2.62 / 3.07

3.74 / 4.39

22 + 35 + 60

1.50 / 1.77

2.39 / 2.81

4.10 / 4.82

22 + 35 + 71

1.38 / 1.62

2.19 / 2.57

4.44 / 5.21

22 + 50 + 50

1.44 / 1.70

3.28 / 3.85

3.28 / 3.85

22 + 50 + 60

1.33 / 1.57

3.03 / 3.56

3.64 / 4.27

22 + 50 + 71

1.23 / 1.45

2.80 / 3.29

3.97 / 4.67

25 + 25 + 25

2.50 / 3.00

2.50 / 3.00

2.50 / 3.00

35 + 50

2.80 / 3.54

4.00 / 5.06

35 + 60

2.51 / 3.17

4.29 / 5.43

50 + 50

3.40 / 4.30

3.40 / 4.30

50 + 60

3.09 / 3.91

3.71 / 4.69

60 + 60

3.40 / 4.30

3.40 / 4.30

MXZ-4C80VA 1 Outdoor Unit Indoor unit combination

Up to 4 Indoor Units Cooling / Heating Capacity (kW) Unit A

Unit B

1 ROOM

Unit C

Unit D

22 + 22 + 22

2.20 / 2.87

2.20 / 2.87

2.20 / 2.87

22

2.20 / 3.30

22 + 22 + 25

2.20 / 2.74

2.20 / 2.74

2.50 / 3.12

25

2.50 / 3.60

22 + 22 + 35

1.98 / 2.39

1.98 / 2.39

3.15 / 3.81

35

3.50 / 4.00

22 + 22 + 50

1.66 / 2.01

1.66 / 2.01

3.78 / 4.57

50

5.00 / 7.20

25 + 25 + 35

2.29 / 2.76

2.29 / 2.76

3.21 / 3.87

22 + 22 + 60

1.50 / 1.82

1.50 / 1.82

4.10 / 4.96

60

6.00 / 7.90

25 + 25 + 50

1.98 / 2.35

1.98 / 2.35

3.95 / 4.70

22 + 25 + 25

2.17 / 2.63

2.47 / 2.99

2.47 / 2.99

71

7.10 / 8.60

25 + 25 + 60

1.82 / 2.14

1.82 / 2.14

4.36 / 5.13

22 + 25 + 35

1.90 / 2.31

2.16 / 2.62

3.03 / 3.67

22 + 25 + 50

1.61 / 1.95

1.83 / 2.22

3.66 / 4.43

25 + 25 + 71

1.65 / 1.94

1.65 / 1.94

4.69 / 5.52

22 + 25 + 60

1.46 / 1.77

1.66 / 2.01

3.98 / 4.82

25 + 35 + 35

2.08 / 2.47

2.91 / 3.46

2.91 / 3.46

22 + 35 + 35

1.70 / 2.06

2.70 / 3.27

2.70 / 3.27

25 + 35 + 50

1.82 / 2.14

2.55 / 2.99

3.64 / 4.27

22 + 35 + 50

1.46 / 1.77

2.32 / 2.81

3.32 / 4.02

25 + 35 + 60

1.67 / 1.96

2.33 / 2.74

4.00 / 4.70

22 + 35 + 60

1.34 / 1.62

2.12 / 2.57

3.64 / 4.41

1.53 / 1.79

2.14 / 2.51

4.34 / 5.09

2 ROOMS 22 + 22

2.20 / 3.30

2.20 / 3.30

22 + 25

2.20 / 3.23

2.50 / 3.67

22 + 35

2.20 / 2.89

3.50 / 4.61

Unit D

3 ROOMS

22 + 22 + 50

3 ROOMS

2 ROOMS 22 22 22 22 25 25 25 35 35 50

Unit B

2 ROOMS

MXZ-3C54VA 1 Outdoor Unit

Cooling / Heating Capacity (kW)

1 ROOM 2.20 / 3.30 2.50 / 3.60 3.50 / 4.00

2 ROOMS 22 22 22 25 25 35

Up to 4 Indoor Units

Unit A

Unit B

1 ROOM 22 25 35

Indoor unit combination

Cooling / Heating Capacity (kW)

4 ROOMS

MXZ-4C71VA

MXZ-2C52VA

Indoor unit combination

22 + 50 + 50

1.28 / 1.55

2.91 / 3.52

2.91 / 3.52

22 + 50

2.20 / 2.51

5.00 / 5.69

25 + 35 + 71

25 + 25 + 25

2.37 / 2.87

2.37 / 2.87

2.37 / 2.87

22 + 60

2.09 / 2.52

5.71 / 6.88

25 + 50 + 50

1.60 / 1.88

3.20 / 3.76

3.20 / 3.76

25 + 25 + 35

2.09 / 2.53

2.09 / 2.53

2.92 / 3.54

22 + 71

1.87 / 2.22

6.03 / 7.18

25 + 50 + 60

1.48 / 1.74

2.96 / 3.48

3.56 / 4.18

25 + 25 + 50

1.78 / 2.15

1.78 / 2.15

3.55 / 4.30

25 + 25

2.50 / 3.60

2.50 / 3.60

35 + 35 + 35

2.65 / 3.13

2.65 / 3.13

2.65 / 3.13

25 + 25 + 60

1.61 / 1.95

1.61 / 1.95

3.87 / 4.69

25 + 35

2.50 / 3.17

3.50 / 4.43

25 + 35 + 35

1.87 / 2.26

2.62 / 3.17

2.62 / 3.17

35 + 35 + 50

2.33 / 2.74

2.33 / 2.74

3.33 / 3.92

25 + 50

2.50 / 2.87

5.00 / 5.73

25 + 35 + 50

1.61 / 1.95

2.26 / 2.74

3.23 / 3.91

25 + 60

2.29 / 2.76

5.51 / 6.64

35 + 35 + 60

2.15 / 2.53

2.15 / 2.53

3.69 / 4.34

25 + 35 + 60

1.48 / 1.79

2.07 / 2.51

3.55 / 4.30

4.03 / 4.73

2.84 / 3.44

5.84 / 6.95

1.99 / 2.33

2.84 / 3.44

2.06 / 2.45

1.99 / 2.33

1.42 / 1.72

25 + 71

35 + 35 + 71

25 + 50 + 50

2.07 / 2.44

2.96 / 3.48

2.96 / 3.48

35 + 35 + 35

2.37 / 2.87

2.37 / 2.87

2.37 / 2.87

35 + 35 + 50

2.07 / 2.51

2.07 / 2.51

2.96 / 3.58

1.93 / 2.27

2.76 / 3.24

3.31 / 3.89

35 + 35

3.50 / 4.00

3.50 / 4.00

35 + 50 + 50

35 + 50

3.21 / 3.87

4.59 / 5.53

35 + 50 + 60

Page 39


Indoor unit combination

Cooling / Heating Capacity (kW) Unit A

Unit B

Unit C

Indoor unit combination

Unit D

Cooling / Heating Capacity (kW) Unit A

Unit B

22 + 22 + 22 + 22

1.95 / 2.35

1.95 / 2.35

1.95 / 2.35

1.95 / 2.35

22 + 22

2.20 / 3.30

2.20 / 3.30

22 + 22 + 22 + 25

1.90 / 2.27

1.90 / 2.27

1.90 / 2.27

2.16 / 2.58

22 + 25

2.20 / 3.23

2.50 / 3.67

22 + 22 + 22 + 35

1.73 / 2.05

22 + 35

2.20 / 2.89

3.50 / 4.61

22 + 50

2.17 / 2.57

4.93 / 5.83

22 + 60

2.07 / 2.71

5.63 / 7.39

22 + 22 + 22 + 50

1.52 / 1.78

1.73 / 2.05 1.52 / 1.78

1.73 / 2.05 1.52 / 1.78

2.75 / 3.26 3.45 / 4.05

22 + 22 + 22 + 60

1.40 / 1.64

1.40 / 1.64

1.40 / 1.64

3.81 / 4.48

22 + 22 + 22 + 71

1.28 / 1.51

1.28 / 1.51

1.28 / 1.51

4.15 / 4.87

22 + 22 + 25 + 25

1.84 / 2.20

1.84 / 2.20

2.09 / 2.50

2.09 / 2.50

22 + 22 + 25 + 35

1.68 / 1.99

1.68 / 1.99

1.91 / 2.26

2.68 / 3.16

22 + 22 + 25 + 50

1.48 / 1.74

1.48 / 1.74

1.68 / 1.97

3.36 / 3.95

25 + 35

2.50 / 3.17

3.50 / 4.43

22 + 22 + 25 + 60

1.36 / 1.60

1.36 / 1.60

1.55 / 1.82

3.72 / 4.37

25 + 50

2.43 / 2.97

4.87 / 5.93

22 + 22 + 25 + 71

1.26 / 1.48

1.26 / 1.48

1.43 / 1.68

4.06 / 4.77

25 + 60

2.29 / 3.09

5.51 / 7.41

22 + 22 + 35 + 35

Unit C

2 ROOMS

4 ROOMS

1.54 / 1.81

1.54 / 1.81

2.46 / 2.89

2.46 / 2.89

22 + 22 + 35 + 50

1.36 / 1.60

1.36 / 1.60

2.17 / 2.55

3.10 / 3.64

22 + 22 + 35 + 60

1.27 / 1.49

1.27 / 1.49

2.01 / 2.37

3.45 / 4.06

22 + 22 + 50 + 50

1.22 / 1.44

1.22 / 1.44

2.78 / 3.26

2.78 / 3.26

22 + 25 + 25 + 25

1.79 / 2.13

2.04 / 2.42

2.04 / 2.42

2.04 / 2.42

22 + 25 + 25 + 35

1.63 / 1.93

1.86 / 2.20

1.86 / 2.20

2.60 / 3.07

22 + 25 + 25 + 50

1.44 / 1.70

1.64 / 1.93

1.64 / 1.93

3.28 / 3.85

22 + 71 25 + 25

25 + 71 35 + 35 35 + 50 35 + 60 35 + 71

1.92 / 2.51 2.50 / 3.60

2.14 / 2.76 3.50 / 4.00 3.21 / 4.32 2.98 / 3.91 2.81 / 3.50

Indoor unit combination

Cooling / Heating Capacity (kW) Unit A

Unit B

Unit C

25 + 25 + 25

2.50 / 3.00

2.50 / 3.00

2.50 / 3.00

25 + 25 + 35

2.32 / 2.74

2.32 / 2.74

25 + 25 + 50

2.10 / 2.45

2.10 / 2.45

25 + 25 + 60

1.98 / 2.32

25 + 25 + 71

Unit B

Unit C

Unit D

22 + 22 + 35 + 71

1.39 / 1.61

1.39 / 1.61

2.22 / 2.57

4.50 / 5.21

3.25 / 3.83

22 + 22 + 50 + 50

1.45 / 1.68

1.45 / 1.68

3.30 / 3.82

3.30 / 3.82

4.20 / 4.90

22 + 22 + 50 + 60

1.37 / 1.57

1.37 / 1.57

3.12 / 3.57

3.74 / 4.29

1.98 / 2.32

4.75 / 5.56

22 + 22 + 50 + 71

1.31 / 1.47

1.31 / 1.47

2.97 / 3.33

4.22 / 4.73

1.84 / 2.19

1.84 / 2.19

5.22 / 6.22

22 + 25 + 25 + 25

1.93 / 2.27

2.19 / 2.58

2.19 / 2.58

2.19 / 2.58

25 + 35 + 35

2.16 / 2.55

3.02 / 3.57

3.02 / 3.57

22 + 25 + 25 + 35

1.79 / 2.10

2.03 / 2.38

2.03 / 2.38

2.85 / 3.34

25 + 35 + 50

1.98 / 2.32

2.77 / 3.25

3.95 / 4.64

22 + 25 + 25 + 50

1.62 / 1.91

1.84 / 2.17

1.84 / 2.17

3.69 / 4.34

25 + 35 + 60

1.85 / 2.21

2.60 / 3.09

4.45 / 5.30

22 + 25 + 25 + 60

1.53 / 1.80

1.74 / 2.05

1.74 / 2.05

4.18 / 4.91

25 + 35 + 71

1.74 / 2.06

2.43 / 2.89

4.93 / 5.85

22 + 25 + 25 + 71

1.45 / 1.69

1.64 / 1.92

1.64 / 1.92

4.67 / 5.46

25 + 50 + 50

1.80 / 2.16

3.60 / 4.32

3.60 / 4.32

22 + 25 + 35 + 35

1.67 / 1.96

1.90 / 2.22

2.66 / 3.11

2.66 / 3.11

25 + 50 + 60

1.70 / 2.02

3.41 / 4.04

4.09 / 4.84

22 + 25 + 35 + 50

1.53 / 1.80

1.74 / 2.05

2.44 / 2.86

3.48 / 4.09

25 + 50 + 71

1.59 / 1.88

3.18 / 3.77

4.52 / 5.35

22 + 25 + 35 + 60

1.46 / 1.70

1.65 / 1.94

2.32 / 2.71

3.97 / 4.65

25 + 60 + 60

1.60 / 1.90

3.85 / 4.55

3.85 / 4.55

22 + 25 + 35 + 71

1.38 / 1.58

1.57 / 1.80

2.20 / 2.52

4.45 / 5.10

25 + 60 + 71

1.51 / 1.76

3.62 / 4.23

4.28 / 5.01

22 + 25 + 50 + 50

1.42 / 1.65

1.62 / 1.87

3.23 / 3.74

3.23 / 3.74

35 + 35 + 35

2.87 / 3.33

2.87 / 3.33

2.87 / 3.33

22 + 25 + 50 + 60

1.35 / 1.54

1.53 / 1.75

3.06 / 3.50

3.67 / 4.20

2.60 / 3.09

2.60 / 3.09

3.71 / 4.42

22 + 25 + 50 + 71

1.28 / 1.44

1.46 / 1.64

2.92 / 3.27

4.14 / 4.65

22 + 35 + 35 + 35

1.58 / 1.85

2.51 / 2.95

2.51 / 2.95

2.51 / 2.95

22 + 35 + 35 + 50

1.46 / 1.70

2.32 / 2.71

2.32 / 2.71

3.31 / 3.87

22 + 35 + 35 + 60

1.39 / 1.59

2.21 / 2.53

2.21 / 2.53

3.79 / 4.34

22 + 35 + 35 + 71

1.31 / 1.48

2.08 / 2.36

2.08 / 2.36

4.23 / 4.79

22 + 35 + 50 + 50

1.35 / 1.54

2.14 / 2.45

3.06 / 3.50

3.06 / 3.50

22 + 35 + 50 + 60

1.29 / 1.45

2.05 / 2.31

2.93 / 3.29

3.52 / 3.95

25 + 25 + 25 + 25

2.15 / 2.50

2.15 / 2.50

2.15 / 2.50

2.15 / 2.50

25 + 25 + 25 + 35

2.00 / 2.34

2.00 / 2.34

2.00 / 2.34

2.80 / 3.28

25 + 25 + 25 + 50

1.82 / 2.12

1.82 / 2.12

1.82 / 2.12

3.64 / 4.24

25 + 25 + 25 + 60

1.72 / 2.02

1.72 / 2.02

1.72 / 2.02

4.13 / 4.84

25 + 25 + 25 + 71

1.63 / 1.88

1.63 / 1.88

1.63 / 1.88

4.62 / 5.35

25 + 25 + 35 + 35

1.88 / 2.19

1.88 / 2.19

2.63 / 3.06

2.63 / 3.06

25 + 25 + 35 + 50

1.72 / 2.02

1.72 / 2.02

2.41 / 2.83

3.44 / 4.04

25 + 25 + 35 + 60

1.64 / 1.90

1.64 / 1.90

2.29 / 2.66

3.93 / 4.54

2.50 / 3.60

3.50 / 4.00 4.59 / 6.18 5.12 / 6.69 5.69 / 7.10

50 + 50

4.15 / 5.30

4.15 / 5.30

35 + 35 + 50

3.91 / 4.82

4.69 / 5.78

35 + 35 + 60

2.45 / 2.91

2.45 / 2.91

4.20 / 4.98

22 + 25 + 25 + 60

1.33 / 1.57

1.52 / 1.78

1.52 / 1.78

3.64 / 4.27

50 + 60

22 + 25 + 35 + 35

1.50 / 1.77

1.71 / 2.01

2.39 / 2.81

2.39 / 2.81

50 + 71

3.68 / 4.38

5.22 / 6.22

35 + 35 + 71

2.31 / 2.71

2.31 / 2.71

4.68 / 5.49

22 + 25 + 35 + 50

1.33 / 1.57

1.52 / 1.78

2.12 / 2.49

3.03 / 3.56

60 + 60

4.45 / 5.30

4.45 / 5.30

35 + 50 + 50

2.39 / 2.83

3.41 / 4.04

3.41 / 4.04

22 + 25 + 35 + 60

1.24 / 1.46

1.41 / 1.65

1.97 / 2.32

3.38 / 3.97

60 + 71

4.12 / 4.85

4.88 / 5.75

35 + 50 + 60

2.24 / 2.66

3.21 / 3.79

3.85 / 4.55

22 + 35 + 35 + 35

1.39 / 1.63

2.20 / 2.59

2.20 / 2.59

2.20 / 2.59

71 + 71

4.55 / 5.30

4.55 / 5.30

35 + 50 + 71

2.11 / 2.47

3.01 / 3.53

4.28 / 5.01

22 + 35 + 35 + 50

1.24 / 1.45

1.97 / 2.32

1.97 / 2.32

2.82 / 3.31

35 + 60 + 60

2.12 / 2.48

3.64 / 4.26

3.64 / 4.26

25 + 25 + 25 + 25

1.98 / 2.35

1.98 / 2.35

1.98 / 2.35

1.98 / 2.35

3.40 / 3.98

4.02 / 4.70

25 + 25 + 25 + 35

1.82 / 2.14

1.82 / 2.14

2.55 / 2.99

1.98 / 2.32

1.82 / 2.14

35 + 60 + 71

25 + 25 + 25 + 50

1.60 / 1.88

1.60 / 1.88

1.60 / 1.88

3.20 / 3.76

25 + 25 + 25 + 60

1.48 / 1.74

1.48 / 1.74

1.48 / 1.74

3.56 / 4.18

25 + 25 + 35 + 35

1.67 / 1.96

1.67 / 1.96

2.33 / 2.74

25 + 25 + 35 + 50

1.48 / 1.74

1.48 / 1.74

25 + 35 + 35 + 35

1.54 / 1.81

35 + 35 + 35 + 35

2.00 / 2.35

Indoor unit combination

2.20 / 2.90

2.20 / 2.90

2.20 / 2.90

50 + 50 + 50

3.13 / 3.67

3.13 / 3.67

3.13 / 3.67

22 + 22 + 25

2.20 / 2.81

2.20 / 2.81

2.50 / 3.19

50 + 50 + 60

2.94 / 3.44

2.94 / 3.44

3.53 / 4.13

2.33 / 2.74

22 + 22 + 35

2.12 / 2.53

2.12 / 2.53

3.37 / 4.03

50 + 50 + 71

2.75 / 3.22

2.75 / 3.22

3.90 / 4.57

2.07 / 2.44

2.96 / 3.48

22 + 22 + 50

1.92 / 2.25

1.92 / 2.25

4.36 / 5.11

2.15 / 2.53

2.15 / 2.53

2.15 / 2.53

22 + 22 + 60

1.82 / 2.12

1.82 / 2.12

4.96 / 5.77

4 ROOMS

2.00 / 2.35

2.00 / 2.35

2.00 / 2.35

22 + 22 + 71

1.68 / 1.99

1.68 / 1.99

5.43 / 6.42

22 + 22 + 22 + 22

2.00 / 2.50

2.00 / 2.50

2.00 / 2.50

2.00 / 2.50

22 + 25 + 25

2.20 / 2.72

2.50 / 3.09

2.50 / 3.09

22 + 22 + 22 + 25

1.98 / 2.42

1.98 / 2.42

1.98 / 2.42

2.25 / 2.75

22 + 25 + 35

2.09 / 2.47

2.38 / 2.80

3.33 / 3.93

22 + 22 + 22 + 35

1.87 / 2.18

1.87 / 2.18

1.87 / 2.18

2.98 / 3.47

22 + 25 + 50

1.88 / 2.20

2.14 / 2.50

4.28 / 5.00

22 + 22 + 22 + 50

1.69 / 1.97

1.69 / 1.97

1.69 / 1.97

3.84 / 4.48

25 + 25 + 35 + 71

1.54 / 1.76

1.54 / 1.76

2.15 / 2.47

4.37 / 5.01

22 + 25 + 60

1.77 / 2.08

2.01 / 2.36

4.82 / 5.66

22 + 22 + 22 + 60

1.59 / 1.87

1.59 / 1.87

1.59 / 1.87

4.33 / 5.10

25 + 25 + 50 + 50

1.58 / 1.83

1.58 / 1.83

3.17 / 3.67

3.17 / 3.67

22 + 25 + 71

1.64 / 1.96

1.86 / 2.22

5.29 / 6.32

22 + 22 + 22 + 71

1.49 / 1.75

1.49 / 1.75

1.49 / 1.75

4.82 / 5.65

25 + 25 + 50 + 60

1.52 / 1.72

1.52 / 1.72

3.03 / 3.44

3.64 / 4.13

22 + 35 + 35

1.94 / 2.30

3.08 / 3.65

3.08 / 3.65

22 + 22 + 25 + 25

1.94 / 2.34

1.94 / 2.34

2.21 / 2.66

2.21 / 2.66

25 + 25 + 50 + 71

1.43 / 1.61

1.43 / 1.61

2.87 / 3.22

4.07 / 4.57

22 + 35 + 50

1.77 / 2.08

2.81 / 3.30

4.02 / 4.72 22 + 22 + 25 + 35

1.84 / 2.14

1.84 / 2.14

2.09 / 2.43

2.93 / 3.40

25 + 35 + 35 + 35

1.77 / 2.08

2.48 / 2.91

2.48 / 2.91

2.48 / 2.91

22 + 35 + 60

1.65 / 1.97

2.63 / 3.14

4.51 / 5.38 22 + 22 + 25 + 50

1.66 / 1.94

1.66 / 1.94

1.89 / 2.21

3.78 / 4.41

25 + 35 + 35 + 50

1.64 / 1.90

2.29 / 2.66

2.29 / 2.66

3.28 / 3.79

22 + 35 + 71

1.55 / 1.86

2.46 / 2.95

4.99 / 5.99 22 + 22 + 25 + 60

1.57 / 1.82

1.57 / 1.82

1.78 / 2.07

4.28 / 4.98

25 + 35 + 35 + 60

1.55 / 1.77

2.17 / 2.48

2.17 / 2.48

3.72 / 4.26

22 + 50 + 50

1.60 / 1.91

3.65 / 4.34

3.65 / 4.34 1.68 / 1.96

4.77 / 5.58

2.07 / 2.32

4.19 / 4.70

4.14 / 4.95

1.48 / 1.73

2.07 / 2.32

3.45 / 4.13

1.48 / 1.73

1.48 / 1.66

1.52 / 1.82

22 + 22 + 25 + 71

25 + 35 + 35 + 71

22 + 50 + 60 22 + 50 + 71

1.43 / 1.68

3.25 / 3.81

4.62 / 5.41

22 + 22 + 35 + 35

1.72 / 2.01

1.72 / 2.01

2.73 / 3.19

2.73 / 3.19

35 + 35 + 35 + 35

2.35 / 2.75

2.35 / 2.75

2.35 / 2.75

2.35 / 2.75

22 + 22 + 35 + 50

1.57 / 1.82

1.57 / 1.82

2.50 / 2.90

3.57 / 4.15

35 + 35 + 35 + 50

2.17 / 2.48

2.17 / 2.48

2.17 / 2.48

3.10 / 3.55

22 + 22 + 35 + 60

1.49 / 1.74

1.49 / 1.74

2.37 / 2.77

4.06 / 4.75

35 + 35 + 35 + 60

2.08 / 2.33

2.08 / 2.33

2.08 / 2.33

3.56 / 4.00

Up to 5 Indoor Units Cooling / Heating Capacity (kW) Unit A

1 ROOM

3 ROOMS 22 + 22 + 22

MXZ-5C100VA 1 Outdoor Unit

Unit B

Unit C

Unit D

22

2.20 / 3.30

25

2.50 / 3.60

35

3.50 / 4.00

50

5.00 / 7.20

60

6.00 / 7.90

22 + 60 + 60

1.44 / 1.69

3.93 / 4.61

3.93 / 4.61

71

7.10 / 8.60

22 + 60 + 71

1.35 / 1.58

3.69 / 4.31

4.36 / 5.10

Page 40

Unit D

Cooling / Heating Capacity (kW) Unit A

Unit D

6.18 / 8.09

6.06 / 7.84

Indoor unit combination

Page 41


Indoor unit combination

Cooling / Heating Capacity (kW)

MXZ-6C120VA 1 Outdoor Unit

Unit A

Unit B

Unit C

Unit D

Up to 6 Indoor Units

Indoor unit combination

Cooling / Heating Capacity (kW)

22 + 22 + 22 + 22 + 22

2.00 / 2.40

2.00 / 2.40

2.00 / 2.40

2.00 / 2.40

2.00 / 2.40

22 + 22 + 22 + 22 + 25

1.95 / 2.34

1.95 / 2.34

1.95 / 2.34

1.95 / 2.34

2.21 / 2.65

22 + 22 + 22 + 22 + 35

1.79 / 2.15

1.79 / 2.15

1.79 / 2.15

1.79 / 2.15

2.85 / 3.41

1 ROOM

22 + 22 + 22 + 22 + 50

1.59 / 1.91

1.59 / 1.91

1.59 / 1.91

1.59 / 1.91

3.62 / 4.35

22

2.20 / 3.30

22 + 22 + 22 + 22 + 60

1.49 / 1.78

1.49 / 1.78

1.49 / 1.78

1.49 / 1.78

4.05 / 4.86

25

2.50 / 3.60

22 + 22 + 22 + 22 + 71

1.38 / 1.66

1.38 / 1.66

1.38 / 1.66

1.38 / 1.66

4.47 / 5.36

35

3.50 / 4.00

22 + 22 + 22 + 25 + 25

1.90 / 2.28

1.90 / 2.28

1.90 / 2.28

2.16 / 2.59

2.16 / 2.59

50

5.00 / 7.20

22 + 22 + 22 + 25 + 35

1.75 / 2.10

1.75 / 2.10

1.75 / 2.10

1.98 / 2.38

2.78 / 3.33

60

6.00 / 7.90

1.56 / 1.87

1.56 / 1.87

1.56 / 1.87

1.77 / 2.13

3.55 / 4.26

22 + 22 + 22 + 25 + 60

1.46 / 1.75

1.46 / 1.75

1.46 / 1.75

1.66 / 1.99

3.97 / 4.77

22 + 22 + 22 + 25 + 71

1.36 / 1.63

1.36 / 1.63

1.36 / 1.63

1.54 / 1.85

4.38 / 5.26

22 + 22 + 22 + 35 + 35

1.62 / 1.94

1.62 / 1.94

1.62 / 1.94

2.57 / 3.09

2.57 / 3.09

22 + 22 + 22 + 35 + 50

1.46 / 1.75

1.46 / 1.75

1.46 / 1.75

2.32 / 2.78

3.31 / 3.97

22 + 22 + 22 + 35 + 60

1.37 / 1.64

1.37 / 1.64

1.37 / 1.64

2.17 / 2.61

3.73 / 4.47

22 + 22 + 22 + 35 + 71

1.28 / 1.53

1.28 / 1.53

1.28 / 1.53

2.03 / 2.44

4.13 / 4.95

22 + 22 + 25 + 25 + 25

1.85 / 2.22

1.85 / 2.22

2.10 / 2.52

2.10 / 2.52

2.10 / 2.52

22 + 22 + 25 + 25 + 35

1.71 / 2.05

1.71 / 2.05

1.94 / 2.33

1.94 / 2.33

2.71 / 3.26

22 + 22 + 25 + 25 + 50

1.53 / 1.83

1.53 / 1.83

1.74 / 2.08

1.74 / 2.08

3.47 / 4.17

22 + 22 + 25 + 25 + 60

1.43 / 1.71

1.43 / 1.71

1.62 / 1.95

1.62 / 1.95

3.90 / 4.68

22 + 22 + 25 + 25 + 71

1.33 / 1.60

1.33 / 1.60

1.52 / 1.82

1.52 / 1.82

4.30 / 5.16

22 + 22 + 25 + 35 + 35

1.58 / 1.90

1.58 / 1.90

1.80 / 2.16

2.52 / 3.02

2.52 / 3.02

Unit A

71

Unit B

Unit C

Unit D

Cooling / Heating Capacity (kW) Unit A

Unit B

Unit C

22 + 25 + 50

2.02 / 2.65

2.29 / 3.02

4.59 / 6.03

22 + 25 + 60

1.97 / 2.49

2.24 / 2.83

5.38 / 6.79

22 + 25 + 71

1.83 / 2.31

2.08 / 2.63

5.90 / 7.46

22 + 35 + 35

2.13 / 2.75

3.39 / 4.38

3.39 / 4.38

22 + 35 + 50

1.97 / 2.49

3.14 / 3.96

4.49 / 5.65

22 + 35 + 60

1.84 / 2.31

2.93 / 3.68

5.03 / 6.31

22 + 35 + 71

1.72 / 2.17

2.73 / 3.45

5.55 / 6.99

22 + 50 + 50

1.77 / 2.25

4.02 / 5.12

4.02 / 5.12

22 + 50 + 60

1.68 / 2.12

3.83 / 4.81

4.59 / 5.77

22 + 50 + 71

1.60 / 2.00

3.64 / 4.55

5.16 / 6.45

22 + 60 + 60

1.61 / 2.00

4.39 / 5.45

4.39 / 5.45

22 + 60 + 71

1.54 / 1.90

4.20 / 5.18

4.97 / 6.13

22 + 71 + 71

1.48 / 1.78

4.76 / 5.76

4.76 / 5.76

25 + 25 + 25

2.50 / 3.60

2.50 / 3.60

2.50 / 3.60

2.41 / 3.29

2.41 / 3.29

3.38 / 4.61

Unit E

5 ROOMS

22 + 22 + 22 + 25 + 50

Indoor unit combination

7.10 / 8.60

2 ROOMS 22 + 22

2.20 / 3.30

2.20 / 3.30

22 + 25

2.20 / 3.23

2.50 / 3.67

22 + 35

2.20 / 2.89

3.50 / 4.61

25 + 25 + 35

22 + 50

2.20 / 2.57

5.00 / 5.83

25 + 25 + 50

2.40 / 2.95

2.40 / 2.95

4.80 / 5.90

22 + 60

2.20 / 2.79

6.00 / 7.61

25 + 25 + 60

2.20 / 2.75

2.20 / 2.75

5.29 / 6.60

22 + 71

2.06 / 2.63

6.64 / 8.47

25 + 25 + 71

2.02 / 2.58

2.02 / 2.58

5.75 / 7.33

25 + 25

2.50 / 3.60

2.50 / 3.60

25 + 35 + 35

2.34 / 3.05

3.28 / 4.27

3.28 / 4.27

25 + 35

2.50 / 3.17

3.50 / 4.43

25 + 35 + 50

2.20 / 2.75

3.09 / 3.85

4.41 / 5.50

2.50 / 3.00

5.00 / 6.00

25 + 35 + 60

2.04 / 2.58

2.86 / 3.62

4.90 / 6.20

2.47 / 3.18

5.93 / 7.62

25 + 35 + 71

1.91 / 2.42

2.67 / 3.39

5.42 / 6.88

22 + 22 + 25 + 35 + 50

1.43 / 1.71

1.43 / 1.71

1.62 / 1.95

2.27 / 2.73

3.25 / 3.90

25 + 50

22 + 22 + 25 + 35 + 60

1.34 / 1.61

1.34 / 1.61

1.52 / 1.83

2.13 / 2.56

3.66 / 4.39

25 + 60

22 + 22 + 35 + 35 + 35

1.48 / 1.77

1.48 / 1.77

2.35 / 2.82

2.35 / 2.82

2.35 / 2.82

25 + 71

2.29 / 2.92

6.51 / 8.28

25 + 50 + 50

1.98 / 2.52

3.96 / 5.04

3.96 / 5.04

22 + 22 + 35 + 35 + 50

1.34 / 1.61

1.34 / 1.61

2.13 / 2.56

2.13 / 2.56

3.05 / 3.66

35 + 35

3.50 / 4.00

3.50 / 4.00

25 + 50 + 60

1.89 / 2.37

3.78 / 4.74

4.53 / 5.69

22 + 25 + 25 + 25 + 25

1.80 / 2.16

2.05 / 2.46

2.05 / 2.46

2.05 / 2.46

2.05 / 2.46

35 + 50

3.46 / 4.45

4.94 / 6.35

25 + 50 + 71

1.80 / 2.23

3.60 / 4.45

5.11 / 6.32

22 + 25 + 25 + 25 + 35

1.67 / 2.00

1.89 / 2.27

1.89 / 2.27

1.89 / 2.27

2.65 / 3.18

35 + 60

3.21 / 4.09

5.49 / 7.01

25 + 60 + 60

1.81 / 2.24

4.34 / 5.38

4.34 / 5.38

22 + 25 + 25 + 25 + 50

1.50 / 1.80

1.70 / 2.04

1.70 / 2.04

1.70 / 2.04

3.40 / 4.08

35 + 71

3.00 / 3.73

6.10 / 7.57

25 + 60 + 71

1.73 / 2.12

4.15 / 5.08

4.92 / 6.01

22 + 25 + 25 + 25 + 60

1.40 / 1.68

1.59 / 1.91

1.59 / 1.91

1.59 / 1.91

3.82 / 4.59

50 + 50

4.45 / 5.65

4.45 / 5.65

22 + 25 + 25 + 25 + 71

25 + 71 + 71

1.66 / 2.01

4.72 / 5.70

4.72 / 5.70

1.31 / 1.57

1.49 / 1.79

1.49 / 1.79

1.49 / 1.79

4.23 / 5.07

50 + 60

4.23 / 5.14

5.07 / 6.16

22 + 25 + 25 + 35 + 35

1.55 / 1.86

1.76 / 2.11

1.76 / 2.11

2.46 / 2.96

2.46 / 2.96

35 + 35 + 35

3.20 / 4.00

3.20 / 4.00

3.20 / 4.00

50 + 71

3.97 / 4.67

5.63 / 6.63

22 + 25 + 25 + 35 + 50

1.40 / 1.68

1.59 / 1.91

1.59 / 1.91

2.23 / 2.68

3.18 / 3.82

35 + 35 + 50

2.86 / 3.62

2.86 / 3.62

4.08 / 5.17

60 + 60

4.80 / 5.65

4.80 / 5.65 35 + 35 + 60

2.69 / 3.42

2.69 / 3.42

4.62 / 5.86

60 + 71

4.44 / 5.18

5.26 / 6.12 35 + 35 + 71

2.56 / 3.20

2.56 / 3.20

5.19 / 6.50

22 + 25 + 25 + 35 + 60

1.32 / 1.58

1.50 / 1.80

1.50 / 1.80

2.10 / 2.51

3.59 / 4.31

22 + 25 + 35 + 35 + 35

1.45 / 1.74

1.64 / 1.97

2.30 / 2.76

2.30 / 2.76

2.30 / 2.76

22 + 25 + 35 + 35 + 50

1.32 / 1.58

1.50 / 1.80

2.10 / 2.51

2.10 / 2.51

2.99 / 3.59

35 + 50 + 50

2.64 / 3.32

3.78 / 4.74

3.78 / 4.74

22 + 35 + 35 + 35 + 35

1.36 / 1.63

2.16 / 2.59

2.16 / 2.59

2.16 / 2.59

2.16 / 2.59

35 + 50 + 60

2.53 / 3.14

3.62 / 4.48

4.34 / 5.38

25 + 25 + 25 + 25 + 25

2.00 / 2.40

2.00 / 2.40

2.00 / 2.40

2.00 / 2.40

2.00 / 2.40

35 + 50 + 71

2.42 / 2.96

3.46 / 4.23

4.92 / 6.01

25 + 25 + 25 + 25 + 35

1.85 / 2.22

1.85 / 2.22

1.85 / 2.22

1.85 / 2.22

2.59 / 3.11

35 + 60 + 60

2.44 / 2.98

4.18 / 5.11

4.18 / 5.11

25 + 25 + 25 + 25 + 50

1.67 / 2.00

1.67 / 2.00

1.67 / 2.00

1.67 / 2.00

3.33 / 4.00

35 + 60 + 71

2.34 / 2.83

4.01 / 4.84

4.75 / 5.73

25 + 25 + 25 + 25 + 60

1.56 / 1.88

1.56 / 1.88

1.56 / 1.88

1.56 / 1.88

3.75 / 4.50

25 + 25 + 25 + 25 + 71

35 + 71 + 71

2.25 / 2.69

4.57 / 5.46

4.57 / 5.46

1.46 / 1.75

1.46 / 1.75

1.46 / 1.75

1.46 / 1.75

4.15 / 4.98

25 + 25 + 25 + 35 + 35

1.72 / 2.07

1.72 / 2.07

1.72 / 2.07

2.41 / 2.90

25 + 25 + 25 + 35 + 50

1.56 / 1.88

1.56 / 1.88

1.56 / 1.88

25 + 25 + 25 + 35 + 60

1.47 / 1.76

1.47 / 1.76

1.47 / 1.76

71 + 71

4.85 / 5.65

4.85 / 5.65

3 ROOMS 22 + 22 + 22

2.20 / 3.30

2.20 / 3.30

2.20 / 3.30

22 + 22 + 25

2.20 / 3.25

2.20 / 3.25

2.50 / 3.70

22 + 22 + 35

2.09 / 3.06

2.09 / 3.06

3.32 / 4.87

2.41 / 2.90

22 + 22 + 50

2.08 / 2.71

2.08 / 2.71

4.73 / 6.17

50 + 50 + 50

3.53 / 4.37

3.53 / 4.37

3.53 / 4.37

2.19 / 2.63

3.13 / 3.75

22 + 22 + 60

2.03 / 2.54

2.03 / 2.54

5.54 / 6.92

50 + 50 + 60

3.41 / 4.16

3.41 / 4.16

4.09 / 4.99

2.06 / 2.47

3.53 / 4.24

22 + 22 + 71

1.86 / 2.35

1.86 / 2.35

5.99 / 7.59

50 + 50 + 71

3.27 / 3.95

3.27 / 3.95

4.65 / 5.61

3.29 / 3.94

3.95 / 4.73

3.95 / 4.73

3.83 / 4.53

3.83 / 4.53

3.83 / 4.53

25 + 25 + 35 + 35 + 35

1.61 / 1.94

1.61 / 1.94

2.26 / 2.71

2.26 / 2.71

2.26 / 2.71

22 + 25 + 25

2.20 / 3.21

2.50 / 3.65

2.50 / 3.65

50 + 60 + 60

25 + 25 + 35 + 35 + 50

1.47 / 1.76

1.47 / 1.76

2.06 / 2.47

2.06 / 2.47

2.94 / 3.53

22 + 25 + 35

2.20 / 2.98

2.50 / 3.38

3.50 / 4.74

60 + 60 + 60

Page 42

Unit D

Page 43


Indoor unit combination

Cooling / Heating Capacity (kW) Unit A

Unit B

Unit C

Unit D

4 ROOMS 22 + 22 + 22 + 22 22 + 22 + 22 + 25

2.20 / 2.85 2.20 / 2.80

2.20 / 2.85 2.20 / 2.80

2.20 / 2.85 2.20 / 2.80

Indoor unit combination

2.20 / 2.85

Unit A

Unit B

Unit C

Unit D

22 + 35 + 35 + 60

1.55 / 1.91

2.46 / 3.04

2.46 / 3.04

4.22 / 5.21

22 + 35 + 35 + 71

1.46 / 1.78

2.32 / 2.83

2.32 / 2.83

4.70 / 5.75

2.50 / 3.19 22 + 35 + 50 + 50

22 + 22 + 22 + 35 22 + 22 + 22 + 50 22 + 22 + 22 + 60 22 + 22 + 22 + 71 22 + 22 + 25 + 25 22 + 22 + 25 + 35

2.18 / 2.61 1.95 / 2.37 1.83 / 2.23 1.70 / 2.10 2.20 / 2.74 2.14 / 2.56

2.18 / 2.61 1.95 / 2.37 1.83 / 2.23 1.70 / 2.10 2.20 / 2.74 2.14 / 2.56

2.18 / 2.61 1.95 / 2.37 1.83 / 2.23 1.70 / 2.10 2.50 / 3.11 2.43 / 2.91

Cooling / Heating Capacity (kW)

1.51 / 1.85

2.41 / 2.94

3.44 / 4.20

3.44 / 4.20

3.47 / 4.17 22 + 35 + 50 + 60

1.42 / 1.74

2.26 / 2.77

3.23 / 3.95

3.88 / 4.74

22 + 35 + 50 + 71

1.33 / 1.56

2.12 / 2.48

3.03 / 3.54

4.31 / 5.03

4.44 / 5.39 5.00 / 6.10 5.49 / 6.79 2.50 / 3.11 3.40 / 4.07

22 + 35 + 60 + 60 22 + 50 + 50 + 50 25 + 25 + 25 + 25

1.34 / 1.57 1.38 / 1.61 2.50 / 3.00

2.14 / 2.49 3.14 / 3.66 2.50 / 3.00

3.66 / 4.27 3.14 / 3.66 2.50 / 3.00

3.66 / 4.27 3.14 / 3.66 2.50 / 3.00

22 + 22 + 25 + 50

1.90 / 2.33

1.90 / 2.33

2.16 / 2.65

4.33 / 5.29

25 + 25 + 25 + 35

2.32 / 2.80

2.32 / 2.80

2.32 / 2.80

3.25 / 3.91

22 + 22 + 25 + 60

1.79 / 2.20

1.79 / 2.20

2.03 / 2.50

4.88 / 6.00

25 + 25 + 25 + 50

2.08 / 2.56

2.08 / 2.56

2.08 / 2.56

4.16 / 5.12

22 + 22 + 25 + 71

1.68 / 2.07

1.68 / 2.07

1.91 / 2.36

5.43 / 6.69

22 + 22 + 35 + 35

1.97 / 2.39

1.97 / 2.39

3.13 / 3.81

3.13 / 3.81

22 + 22 + 35 + 50 22 + 22 + 35 + 60 22 + 22 + 35 + 71

1.79 / 2.20 1.69 / 2.09 1.57 / 1.94

1.79 / 2.20 1.69 / 2.09 1.57 / 1.94

2.85 / 3.50 2.69 / 3.32 2.50 / 3.08

4.07 / 5.00 4.62 / 5.70

25 + 25 + 25 + 60

1.63 / 2.02

1.63 / 2.02

3.72 / 4.58

1.54 / 1.89

1.54 / 1.89

3.51 / 4.29

22 + 22 + 60 + 60 22 + 22 + 60 + 71 22 + 25 + 25 + 25 22 + 25 + 25 + 35

1.44 / 1.76 1.45 / 1.77 1.36 / 1.58 2.20 / 270 2.08 / 2.51

1.44 / 1.76 1.45 / 1.77 1.36 / 1.58 2.50 / 3.07 2.36 / 2.85

3.27 / 4.00 3.95 / 4.83 3.70 / 4.32 2.50 / 3.07 2.36 / 2.85

1.83 / 2.26

5.20 / 6.42

25 + 25 + 35 + 35

2.17 / 2.63

2.17 / 2.63

3.03 / 3.68

3.03 / 3.68

25 + 25 + 35 + 50

1.96 / 2.43

1.96 / 2.43

2.75 / 3.40

3.93 / 4.85

5.06 / 6.25 1.84 / 2.28

1.84 / 2.28

2.58 / 3.19

4.43 / 5.46

3.72 / 4.58 1.73 / 2.12

1.73 / 2.12

2.42 / 2.96

4.92 / 6.01

4.21 / 5.14 1.78 / 2.20

1.78 / 2.20

3.57 / 4.40

3.57 / 4.40

4.65 / 5.68 3.95 / 4.83 4.38 / 5.11

25 + 25 + 50 + 60 25 + 25 + 50 + 71

2.50 / 3.07

25 + 25 + 60 + 60

3.30 / 3.99

25 + 35 + 35 + 35

22 + 25 + 25 + 50

1.88 / 2.29

2.13 / 2.60

2.13 / 2.60

4.26 / 5.20

22 + 25 + 25 + 60

1.77 / 2.17

2.01 / 2.46

2.01 / 2.46

4.82 / 5.91

22 + 25 + 25 + 71

1.65 / 2.03

1.87 / 2.31

1.87 / 2.31

5.31 / 6.55

22 + 25 + 35 + 35

1.94 / 2.35

2.20 / 2.67

3.08 / 3.74

3.08 / 3.74

22 + 25 + 35 + 50

1.77 / 2.17

2.01 / 2.46

2.81 / 3.45

4.02 / 4.92

22 + 25 + 35 + 60

1.66 / 2.05

1.88 / 2.32

2.64 / 3.25

4.52 / 5.58

25 + 35 + 35 + 50 25 + 35 + 35 + 60 25 + 35 + 35 + 71

22 + 25 + 35 + 71

1.54 / 1.90

1.75 / 2.16

2.45 / 3.02

4.97 / 6.13

22 + 25 + 50 + 50

1.60 / 1.98

1.82 / 2.24

3.64 / 4.49

3.64 / 4.49

1.72 / 2.10

3.44 / 4.20

4.13 / 5.04

22 + 25 + 50 + 71

1.41 / 1.73

1.61 / 1.96

3.21 / 3.93

4.56 / 5.58

22 + 25 + 60 + 60

1.42 / 1.74

1.62 / 1.98

3.88 / 4.74

3.88 / 4.74

22 + 25 + 60 + 71

1.33 / 1.56

1.52 / 1.77

3.64 / 4.25

4.31 / 5.03

1.59 / 1.85 2.02 / 2.48 1.84 / 2.28 1.74 / 2.13 1.63 / 1.99

25 + 35 + 50 + 60

1.59 / 1.85

35 + 35 + 35 + 35 1.51 / 1.85

1.58 / 1.84

1.69 / 2.06

25 + 50 + 50 + 50

22 + 25 + 50 + 60

1.69 / 2.06

25 + 35 + 50 + 50

25 + 35 + 60 + 60

150 / 1.75 1.54 / 1.80 2.68 / 3.30

1.69 / 2.06 1.58 / 1.84 1.59 / 1.85 2.83 / 3.47 2.58 / 3.19 2.44 / 2.98 2.28 / 2.78 2.36 / 2.89 2.22 / 2.59 2.10 / 2.45 3.09 / 3.60 2.68 / 3.30

3.38 / 4.13 3.16 / 3.68 3.81 / 4.45 2.83 / 3.47 2.58 / 3.19 2.44 / 2.98 2.28 / 2.78 3.38 / 4.13 3.18 / 3.71 3.60 / 4.20 3.09 / 3.60 2.68 / 3.30

4.05 / 4.95 4.48 / 5.23 3.81 / 4.45 2.83 / 3.47 3.69 / 4.55 4.18 / 5.11 4.62 / 5.65 3.38 / 4.13 3.81 / 4.45 3.60 / 4.20 3.09 / 3.60 2.68 / 3.30

35 + 35 + 35 + 50

2.44 / 2.98

2.44 / 2.98

2.44 / 2.98

3.48 / 4.26

35 + 35 + 35 + 60

2.29 / 2.80

2.29 / 2.80

2.29 / 2.80

3.93 / 4.80

35 + 35 + 35 + 71

22 + 35 + 35 + 35

1.83 / 2.22

2.89 / 3.53

2.89 / 3.53

2.89 / 3.53

35 + 35 + 50 + 50

22 + 35 + 35 + 50

1.66 / 2.05

2.64 / 3.25

2.64 / 3.25

3.77 / 4.65

35 + 35 + 50 + 60

Page 44

4.71 / 5.82

1.83 / 2.26

25 + 25 + 50 + 50 22 + 22 + 50 + 71

1.96 / 2.43

1.83 / 2.26

25 + 25 + 35 + 71 22 + 22 + 50 + 60

1.96 / 2.43

25 + 25 + 25 + 71

25 + 25 + 35 + 60 22 + 22 + 50 + 50

1.96 / 2.43

2.15 / 2.51 2.22 / 2.59 2.10 / 2.45

2.15 / 2.51 2.22 / 2.59 2.10 / 2.45

2.15 / 2.51 3.18 / 3.71 3.00 / 3.50

4.36 / 5.08 3.18 / 3.71 3.60 / 4.20

Indoor unit combination

Cooling / Heating Capacity (kW) Unit A

Unit B

Unit C

Unit D

Unit E

22 + 22 + 22 + 22 + 22

2.20 / 2.62

2.20 / 2.62

2.20 / 2.62

2.20 / 2.62

2.20 / 2.62

22 + 22 + 22 + 22 + 25

2.18 / 2.57

2.18 / 2.57

2.18 / 2.57

2.18 / 2.57

2.48 / 2.92

22 + 22 + 22 + 22 + 35

2.11 / 2.40

2.11 / 2.40

2.11 / 2.40

2.11 / 2.40

3.36 / 3.81

22 + 22 + 22 + 22 + 50

1.91 / 2.14

1.91 / 2.14

1.91 / 2.14

1.91 / 2.14

4.35 / 4.86

22 + 22 + 22 + 22 + 60

1.78 / 1.99

1.78 / 1.99

1.78 / 1.99

1.78 / 1.99

4.86 / 5.43

22 + 22 + 22 + 22 + 71

1.67 / 1.85

1.67 / 1.85

1.67 / 1.85

1.67 / 1.85

5.40 / 5.98

22 + 22 + 22 + 25 + 25

2.16 / 2.50

2.16 / 2.50

2.16 / 2.50

2.46 / 2.84

2.46 / 2.84

22 + 22 + 22 + 25 + 35

2.08 / 2.34

2.08 / 2.34

2.08 / 2.34

2.36 / 2.66

3.31 / 3.72

22 + 22 + 22 + 25 + 50

1.87 / 2.09

1.87 / 2.09

1.87 / 2.09

2.13 / 2.38

4.26 / 4.75

22 + 22 + 22 + 25 + 60

1.76 / 1.95

1.76 / 1.95

1.76 / 1.95

2.00 / 2.22

4.81 / 5.32

22 + 22 + 22 + 25 + 71

1.64 / 1.82

1.64 / 1.82

1.64 / 1.82

1.87 / 2.07

5.30 / 5.87

22 + 22 + 22 + 35 + 35

1.94 / 2.17

1.94 / 2.17

1.94 / 2.17

3.09 / 3.45

3.09 / 3.45

22 + 22 + 22 + 35 + 50

1.76 / 1.95

1.76 / 1.95

1.76 / 1.95

2.80 / 3.11

4.01 / 4.44

22 + 22 + 22 + 35 + 60

1.65 / 1.83

1.65 / 1.83

1.65 / 1.83

2.63 / 2.91

4.51 / 4.99

22 + 22 + 22 + 35 + 71

1.56 / 1.71

1.56 / 1.71

1.56 / 1.71

2.48 / 2.73

5.04 / 5.53

22 + 22 + 22 + 50 + 50

1.60 / 1.78

1.60 / 1.78

1.60 / 1.78

3.64 / 4.04

3.64 / 4.04

22 + 22 + 22 + 50 + 60

1.53 / 1.68

1.53 / 1.68

1.53 / 1.68

3.47 / 3.81

4.16 / 4.57

22 + 22 + 25 + 25 + 25

2.13 / 2.46

2.13 / 2.46

2.42 / 2.79

2.42 / 2.79

2.42 / 2.79

22 + 22 + 25 + 25 + 35

2.03 / 2.29

2.03 / 2.29

2.31 / 2.60

2.31 / 2.60

3.23 / 3.64

22 + 22 + 25 + 25 + 50

1.83 / 2.05

1.83 / 2.05

2.08 / 2.33

2.08 / 2.33

4.17 / 4.65

22 + 22 + 25 + 25 + 60

1.73 / 1.91

1.73 / 1.91

1.96 / 2.18

1.96 / 2.18

4.71 / 5.22

22 + 22 + 25 + 25 + 71

1.61 / 1.79

1.61 / 1.79

1.83 / 2.03

1.83 / 2.03

5.21 / 5.77

22 + 22 + 25 + 35 + 35

1.90 / 2.12

1.90 / 2.12

2.16 / 2.41

3.02 / 3.37

3.02 / 3.37

22 + 22 + 25 + 35 + 50

1.73 / 1.91

1.73 / 1.91

1.96 / 2.18

2.75 / 3.05

3.93 / 4.35

22 + 22 + 25 + 35 + 60

1.62 / 1.80

1.62 / 1.80

1.84 / 2.04

2.58 / 2.86

4.43 / 4.90

22 + 22 + 25 + 35 + 71

1.53 / 1.68

1.53 / 1.68

1.74 / 1.91

2.44 / 2.68

4.95 / 5.44

22 + 22 + 25 + 50 + 50

1.59 / 1.74

1.59 / 1.74

1.80 / 1.98

3.61 / 3.96

3.61 / 3.96

22 + 22 + 25 + 50 + 60

1.50 / 1.65

1.50 / 1.65

1.70 / 1.87

3.41 / 3.74

4.09 / 4.49

22 + 22 + 35 + 35 + 35

1.77 / 1.98

1.77 / 1.98

2.82 / 3.15

2.82 / 3.15

2.82 / 3.15

22 + 22 + 35 + 35 + 50

1.62 / 1.80

1.62 / 1.80

2.58 / 2.86

2.58 / 2.86

3.69 / 4.09

22 + 22 + 35 + 35 + 60

1.54 / 1.69

1.54 / 1.69

2.45 / 2.70

2.45 / 2.70

4.21 / 4.62

22 + 22 + 35 + 50 + 50

1.50 / 1.65

1.50 / 1.65

2.39 / 2.62

3.41 / 3.74

3.41 / 3.74

22 + 25 + 25 + 25 + 25

2.11 / 2.40

2.40 / 2.73

2.40 / 2.73

2.40 / 2.73

2.40 / 2.73

22 + 25 + 25 + 25 + 35

1.98 / 2.23

2.25 / 2.54

2.25 / 2.54

2.25 / 2.54

3.17 / 3.55

22 + 25 + 25 + 25 + 50

1.80 / 2.01

2.04 / 2.28

2.04 / 2.28

2.04 / 2.28

4.08 / 4.56

22 + 25 + 25 + 25 + 60

1.70 / 1.88

1.93 / 2.13

1.93 / 2.13

1.93 / 2.13

4.62 / 5.12

22 + 25 + 25 + 25 + 71

1.60 / 1.75

1.82 / 1.99

1.82 / 1.99

1.82 / 1.99

5.16 / 5.66

22 + 25 + 25 + 35 + 35

1.86 / 2.08

2.11 / 2.36

2.11 / 2.36

2.96 / 3.30

2.96 / 3.30

22 + 25 + 25 + 35 + 50

1.70 / 1.88

1.93 / 2.13

1.93 / 2.13

2.70 / 2.99

3.85 / 4.27

22 + 25 + 25 + 35 + 60

1.61 / 1.77

1.83 / 2.01

1.83 / 2.01

2.56 / 2.81

4.38 / 4.81

22 + 25 + 25 + 35 + 71

1.51 / 1.66

1.71 / 1.88

1.71 / 1.88

2.40 / 2.63

4.87 / 5.34

22 + 25 + 25 + 50 + 50

1.56 / 1.71

1.77 / 1.95

1.77 / 1.95

3.55 / 3.90

3.55 / 3.90

22 + 25 + 35 + 35 + 35

1.75 / 1.94

1.99 / 2.20

2.79 / 3.09

2.79 / 3.09

2.79 / 3.09

22 + 25 + 35 + 35 + 50

1.61 / 1.77

1.83 / 2.01

2.56 / 2.81

2.56 / 2.81

3.65 / 4.01

22 + 25 + 35 + 35 + 60

1.52 / 1.67

1.72 / 1.89

2.41 / 2.65

2.41 / 2.65

4.14 / 4.54

22 + 35 + 35 + 35 + 35

1.64 / 1.82

2.61 / 2.90

2.61 / 2.90

2.61 / 2.90

2.61 / 2.90

22 + 35 + 35 + 35 + 50

1.52 / 1.67

2.41 / 2.65

2.41 / 2.65

2.41 / 2.65

3.45 / 3.79

25 + 25 + 25 + 25 + 25

2.38 / 2.68

2.38 / 2.68

2.38 / 2.68

2.38 / 2.68

2.38 / 2.68

25 + 25 + 25 + 25 + 35

2.22 / 2.48

2.22 / 2.48

2.22 / 2.48

2.22 / 2.48

3.12 / 3.47

25 + 25 + 25 + 25 + 50

2.02 / 2.23

2.02 / 2.23

2.02 / 2.23

2.02 / 2.23

4.03 / 4.47

25 + 25 + 25 + 25 + 60

1.89 / 2.09

1.89 / 2.09

1.89 / 2.09

1.89 / 2.09

4.54 / 5.03

25 + 25 + 25 + 25 + 71

1.78 / 1.96

1.78 / 1.96

1.78 / 1.96

1.78 / 1.96

5.07 / 5.56

25 + 25 + 25 + 35 + 35

2.07 / 2.31

2.07 / 2.31

2.07 / 2.31

2.90 / 3.23

2.90 / 3.23

5 ROOMS

Page 45


Indoor unit combination

Cooling / Heating Capacity (kW)

MXZ-8B140VA 1 Outdoor Unit

Up to 8 Indoor Units

Unit A

Unit B

Unit C

Unit D

Unit E

25 + 25 + 25 + 35 + 50

1.89 / 2.09

1.89 / 2.09

1.89 / 2.09

2.65 / 2.93

3.78 / 4.19

25 + 25 + 25 + 35 + 60

1.79 / 1.97

1.79 / 1.97

1.79 / 1.97

2.51 / 2.76

4.31 / 4.73

25 + 25 + 25 + 50 + 50

1.74 / 1.91

1.74 / 1.91

1.74 / 1.91

3.49 / 3.83

3.49 / 3.83

25 + 25 + 35 + 35 + 35

1.95 / 2.16

1.95 / 2.16

2.73 / 3.03

2.73 / 3.03

2.73 / 3.03

1 ROOM

25 + 25 + 35 + 35 + 50

1.79 / 1.97

1.79 / 1.97

2.51 / 2.76

2.51 / 2.76

3.59 / 3.94

22

2.20 / 3.30

25 + 25 + 35 + 35 + 60

1.69 / 1.86

1.69 / 1.86

2.37 / 2.61

2.37 / 2.61

4.07 / 4.47

25

2.50 / 3.60

25 + 35 + 35 + 35 + 35

1.83 / 2.03

2.57 / 2.84

2.57 / 2.84

2.57 / 2.84

Indoor unit combination

Cooling / Heating Capacity (kW) Unit A

35

2.57 / 2.84

2.37 / 2.61

2.37 / 2.61

2.37 / 2.61

3.39 / 3.72

50

35 + 35 + 35 + 35 + 35

2.44 / 2.68

2.44 / 2.68

2.44 / 2.68

2.44 / 2.68

2.44 / 2.68

60

6.00 / 7.90

71

7.10 / 8.60

100

10.00 / 11.20

22 + 22 + 22 + 22 + 22 + 25 22 + 22 + 22 + 22 + 22 + 35 22 + 22 + 22 + 22 + 22 + 50 22 + 22 + 22 + 22 + 22 + 60

2.00 / 2.33 1.96 / 2.28 1.82 / 2.12 1.65 / 1.93 1.55 / 1.81

2.00 / 2.33 1.96 / 2.28 1.82 / 2.12 1.65 / 1.93 1.55 / 1.81

2.00 / 2.33 1.96 / 2.28 1.82 / 2.12 1.65 / 1.93 1.55 / 1.81

2.00 / 2.33 1.96 / 2.28 1.82 / 2.12 1.65 / 1.93 1.55 / 1.81

2.00 / 2.33 1.96 / 2.28 1.82 / 2.12 1.65 / 1.93 1.55 / 1.81

2.00 / 2.33 2.22 / 2.59 2.90 / 3.38 3.75 / 4.38 4.24 / 4.94

22 + 22 + 22 + 22 + 25 + 25

1.91 / 2.23

1.91 / 2.23

1.91 / 2.23

1.91 / 2.23

2.17 / 2.54

2.17 / 2.54

22 + 22 + 22 + 22 + 25 + 35

1.78 / 2.08

1.78 / 2.08

1.78 / 2.08

1.78 / 2.08

2.03 / 2.36

2.84 / 3.31

22 + 22 + 22 + 22 + 25 + 50

1.62 / 1.89

1.62 / 1.89

1.62 / 1.89

1.62 / 1.89

1.84 / 2.15

3.68 / 4.29

22 + 22 + 22 + 22 + 25 + 60

1.53 / 1.78

1.53 / 1.78

1.53 / 1.78

1.53 / 1.78

1.73 / 2.02

4.16 / 4.86

22 + 22 + 22 + 22 + 35 + 35

1.67 / 1.95

1.67 / 1.95

1.67 / 1.95

1.67 / 1.95

2.66 / 3.10

2.66 / 3.10

22 + 22 + 22 + 22 + 35 + 50 22 + 22 + 22 + 25 + 25 + 25 22 + 22 + 22 + 25 + 25 + 35

1.53 / 1.78 1.87 / 2.18 1.75 / 2.04

1.53 / 1.78 1.87 / 2.18 1.75 / 2.04

1.53 / 1.78 1.87 / 2.18 1.75 / 2.04

1.53 / 1.78 2.13 / 2.48 1.99 / 2.32

2.43 / 2.83 2.13 / 2.48 1.99 / 2.32

3.47 / 4.05 2.13 / 2.48 2.78 / 3.25

22 + 22 + 22 + 25 + 25 + 50

1.59 / 1.86

1.59 / 1.86

1.59 / 1.86

1.81 / 2.11

1.81 / 2.11

3.61 / 4.22

22 + 22 + 22 + 25 + 25 + 60

1.50 / 1.75

1.50 / 1.75

1.50 / 1.75

1.70 / 1.99

1.70 / 1.99

4.09 / 4.77

22 + 22 + 22 + 25 + 35 + 35

1.64 / 1.91

1.64 / 1.91

1.64 / 1.91

1.86 / 2.17

2.61 / 3.04

2.61 / 3.04

22 + 22 + 22 + 25 + 35 + 50

1.50 / 1.75

1.50 / 1.75

1.50 / 1.75

1.70 / 1.99

2.39 / 2.78

3.41 / 3.98

22 + 22 + 22 + 35 + 35 + 35

1.54 / 1.80

1.54 / 1.80

1.54 / 1.80

2.46 / 2.87

2.46 / 2.87

2.46 / 2.87

22 + 22 + 25 + 25 + 25 + 25

1.83 / 2.14

1.83 / 2.14

2.08 / 2.43

2.08 / 2.43

2.08 / 2.43

2.08 / 2.43

22 + 22 + 25 + 25 + 25 + 35

1.71 / 2.00

1.71 / 2.00

1.95 / 2.27

1.95 / 2.27

1.95 / 2.27

2.73 / 3.18

22 + 22 + 25 + 25 + 25 + 50

1.56 / 1.82

1.56 / 1.82

1.78 / 2.07

1.78 / 2.07

1.78 / 2.07

3.55 / 4.14

22 + 22 + 25 + 25 + 25 + 60 22 + 22 + 25 + 25 + 35 + 35 22 + 22 + 25 + 25 + 35 + 50 22 + 22 + 25 + 35 + 35 + 35 22 + 25 + 25 + 25 + 25 + 25

1.47 / 1.72 1.61 / 1.88 1.47 / 1.72 1.52 / 1.77 1.80 / 2.10

1.47 / 1.72 1.61 / 1.88 1.47 / 1.72 1.52 / 1.77 2.04 / 2.38

1.68 / 1.96 1.83 / 2.13 1.68 / 1.96 1.72 / 2.01 2.04 / 2.38

1.68 / 1.96 1.83 / 2.13 1.68 / 1.96 2.41 / 2.82 2.04 / 2.38

1.68 / 1.96 2.56 / 2.99 2.35 / 2.74 2.41 / 2.82 2.04 / 2.38

4.02 / 4.69 2.56 / 2.99 3.35 / 3.91 2.41 / 2.82 2.04 / 2.38

22 + 25 + 25 + 25 + 25 + 35

1.68 / 1.96

1.91 / 2.23

1.91 / 2.23

1.91 / 2.23

1.91 / 2.23

2.68 / 3.12

22 + 25 + 25 + 25 + 25 + 50

1.53 / 1.79

1.74 / 2.03

1.74 / 2.03

1.74 / 2.03

1.74 / 2.03

3.49 / 4.07

22 + 25 + 25 + 25 + 35 + 35

1.58 / 1.84

1.80 / 2.10

1.80 / 2.10

1.80 / 2.10

2.51 / 2.93

2.51 / 2.93

22 + 25 + 25 + 35 + 35 + 35

1.49 / 1.74

1.69 / 1.98

1.69 / 1.98

2.37 / 2.77

2.37 / 2.77

2.37 / 2.77

25 + 25 + 25 + 25 + 25 + 25

2.00 / 2.33

2.00 / 2.33

2.00 / 2.33

2.00 / 2.33

2.00 / 2.33

2.00 / 2.33

25 + 25 + 25 + 25 + 25 + 35

1.88 / 2.19

1.88 / 2.19

1.88 / 2.19

1.88 / 2.19

1.88 / 2.19

2.63 / 3.06

25 + 25 + 25 + 25 + 25 + 50

1.71 / 2.00

1.71 / 2.00

1.71 / 2.00

1.71 / 2.00

1.71 / 2.00

3.43 / 4.00

25 + 25 + 25 + 25 + 35 + 35 25 + 25 + 25 + 35 + 35 + 35

Page 46

1.76 / 2.06 1.67 / 1.94

1.76 / 2.06 1.67 / 1.94

1.76 / 2.06 1.67 / 1.94

1.76 / 2.06 2.33 / 2.72

2.47 / 2.88 2.33 / 2.72

2.47 / 2.88 2.33 / 2.72

Unit C

3.50 / 4.00

1.69 / 1.86

6 ROOMS

Unit B

5.00 / 7.20

2 ROOMS

Unit D

Cooling / Heating Capacity (kW) Unit A

Unit B

22 + 25 + 50

2.20 / 2.52

2.50 / 2.86

5.00 / 5.72

22 + 25 + 60

2.20 / 2.51

2.50 / 2.85

6.00 / 6.84

22 + 25 + 71

2.20 / 2.52

2.50 / 2.86

7.10 / 8.12

22 + 25 + 100

2.10 / 2.39

2.38 / 2.72

9.52 / 10.88

22 + 35 + 35

2.20 / 2.51

3.50 / 3.99

3.50 / 3.99

22 + 35 + 50

2.20 / 2.51

3.50 / 3.99

5.00 / 5.70

22 + 35 + 60

2.20 / 2.52

3.50 / 4.01

6.00 / 6.87

22 + 35 + 71

2.20 / 2.51

3.50 / 3.99

7.10 / 8.10

22 + 35 + 100

1.96 / 2.24

3.12 / 3.57

8.92 / 10.19

22 + 50 + 50

2.20 / 2.51

5.00 / 5.70

5.00 / 5.70

22 + 50 + 60

2.20 / 2.52

5.00 / 5.72

6.00 / 6.86

22 + 50 + 71

2.15 / 2.46

4.90 / 5.59

6.95 / 7.94

22 + 50 + 100

1.79 / 2.05

4.07 / 4.65

8.14 / 9.30

22 + 60 + 60

2.17 / 2.48

5.92 / 6.76

5.92 / 6.76

Unit F

25 + 35 + 35 + 35 + 50

22 + 22 + 22 + 22 + 22 + 22

Indoor unit combination

Unit C

22 + 22

2.20 / 2.50

2.20 / 2.50

22 + 60 + 71

2.01 / 2.30

5.49 / 6.27

6.50 / 7.42

22 + 25

2.20 / 2.53

2.50 / 2.87

22 + 60 + 100

1.69 / 1.93

4.62 / 5.27

7.69 / 8.79

22 + 35

2.20 / 2.51

3.50 / 3.99

22 + 71 + 71

1.88 / 2.15

6.06 / 6.93

6.06 / 6.93

22 + 50

2.20 / 2.51

5.00 / 5.69

25 + 25 + 25

2.50 / 2.87

2.50 / 2.87

2.50 / 2.87

22 + 60

2.20 / 2.52

6.00 / 6.88

25 + 25 + 35

2.50 / 2.85

2.50 / 2.85

3.50 / 3.99

25 + 25 + 50

2.50 / 2.85

2.50 / 2.85

5.00 / 5.70

25 + 25 + 60

2.50 / 2.86

2.50 / 2.86

6.00 / 6.87

25 + 25 + 71

2.50 / 2.85

2.50 / 2.85

7.10 / 8.10

25 + 25 + 100

2.33 / 2.67

2.33 / 2.67

9.33 / 10.67

22 + 71 22 + 100

2.20 / 2.51

7.10 / 8.09

2.20 / 2.51 10.00 / 11.39

25 + 25

2.50 / 2.85

2.50 / 2.85

25 + 35

2.50 / 2.88

3.50 / 4.03

25 + 35 + 35

2.50 / 2.87

3.50 / 4.02

3.50 / 4.02

25 + 50

2.50 / 2.87

5.00 / 5.73

25 + 35 + 50

2.50 / 2.86

3.50 / 4.01

5.00 / 5.73

25 + 60

2.50 / 2.85

6.00 / 6.85

25 + 35 + 60

2.50 / 2.85

3.50 / 4.00

6.00 / 6.85

25 + 71

2.50 / 2.86

7.10 / 8.14

25 + 35 + 71

2.50 / 2.86

3.50 / 4.01

7.10 / 8.13

25 + 100

2.50 / 2.86 10.00 / 11.44

25 + 35 + 100

2.19 / 2.50

3.06 / 3.50

8.75 / 10.00

35 + 35

3.50 / 4.00

3.50 / 4.00

25 + 50 + 50

2.50 / 2.86

5.00 / 5.72

5.00 / 5.72

5.00 / 5.71

25 + 50 + 60

2.50 / 2.85

5.00 / 5.70

6.00 / 6.84

6.00 / 6.88

25 + 50 + 71

2.40 / 2.74

4.79 / 5.48

6.81 / 7.78

25 + 50 + 100

2.00 / 2.29

4.00 / 4.57

8.00 / 9.14

25 + 60 + 60

2.41 / 2.76

5.79 / 6.62

5.79 / 6.62

25 + 60 + 71

2.24 / 2.56

5.38 / 6.15

6.37 / 7.28

25 + 60 + 100

1.89 / 2.16

4.54 / 5.19

7.57 / 8.65

25 + 71 + 71

2.10 / 2.40

5.95 / 6.80

5.95 / 6.80

35 + 35 + 35

3.50 / 4.00

3.50 / 4.00

3.50 / 4.00

35 + 50 35 + 60 35 + 71 35 + 100 50 + 50

3.50 / 3.99 3.50 / 4.02 3.50 / 4.00

7.10 / 8.10

3.50 / 3.99 10.00 / 11.41 5.00 / 5.70

5.00 / 5.70

50 + 60

5.00 / 5.73

6.00 / 6.87

50 + 71

5.00 / 5.70

7.10 / 8.10

60 + 60

6.00 / 6.85

6.00 / 6.85

35 + 35 + 50

3.50 / 4.00

3.50 / 4.00

5.00 / 5.71

60 + 71

6.00 / 6.87

7.10 / 8.13

35 + 35 + 60

3.50 / 4.01

3.50 / 4.01

6.00 / 6.88

60 + 100

5.25 / 6.00

8.75 / 10.00

35 + 35 + 71

3.48 / 3.97

3.48 / 3.97

7.05 / 8.06

71 + 71

7.00 / 8.00

7.00 / 8.00

35 + 35 + 100

2.88 / 3.29

2.88 / 3.29

8.24 / 9.41

8.19 / 9.36

35 + 50 + 50

3.50 / 3.99

5.00 / 5.70

5.00 / 5.70

35 + 50 + 60

3.38 / 3.86

4.83 / 5.52

5.79 / 6.62

35 + 50 + 71

3.14 / 3.59

4.49 / 5.13

6.37 / 7.28

35 + 50 + 100

2.65 / 3.03

3.78 / 4.32

7.57 / 8.65

35 + 60 + 60

3.16 / 3.61

5.42 / 6.19

5.42 / 6.19

35 + 60 + 71

2.95 / 3.37

5.06 / 5.78

5.99 / 6.84

35 + 71 + 71

2.77 / 3.16

5.62 / 6.42

5.62 / 6.42

50 + 50 + 50

4.67 / 5.33

4.67 / 5.33

4.67 / 5.33

50 + 50 + 60

4.38 / 5.00

4.38 / 5.00

5.25 / 6.00

71 + 100

5.81 / 6.64

3 ROOMS 22 + 22 + 22 22 + 22 + 25 22 + 22 + 35

2.20 / 2.50 2.20 / 2.52

2.20 / 2.50 2.20 / 2.52

2.20 / 2.50 2.50 / 2.86

2.20 / 2.51

2.20 / 2.51

3.50 / 3.99

22 + 22 + 50

2.20 / 2.50

2.20 / 2.50

5.00 / 5.69

22 + 22 + 60

2.20 / 2.52

2.20 / 2.52

6.00 / 6.87

22 + 22 + 71

2.20 / 2.51

2.20 / 2.51

7.10 / 8.09

50 + 50 + 71

4.09 / 4.68

4.09 / 4.68

5.81 / 6.64

22 + 22 + 100

2.14 / 2.44

2.14 / 2.44

9.72 / 11.11

50 + 60 + 60

4.12 / 4.71

4.94 / 5.65

4.94 / 5.65

22 + 25 + 25

2.20 / 2.51

2.50 / 2.85

2.50 / 2.85

50 + 60 + 71

3.87 / 4.42

4.64 / 5.30

5.49 / 6.28

22 + 25 + 35

2.20 / 2.52

2.50 / 2.87

3.50 / 4.01

60 + 60 + 60

4.67 / 5.33

4.67 / 5.33

4.67 / 5.33

Unit D

Page 47


Indoor unit combination

Cooling / Heating Capacity (kW) Unit A

Unit B

Unit C

Indoor unit combination

Unit D

4 ROOMS

Cooling / Heating Capacity (kW) Unit A

Unit B

Unit C

Unit D

22 + 35 + 35 + 60

2.03 / 2.32

3.22 / 3.68

3.22 / 3.68

5.53 / 6.32

Indoor unit combination

Cooling / Heating Capacity (kW) Unit A

Unit B

Unit C

Unit D

Unit E

22 + 22 + 22 + 22 + 22

2.20 / 2.52

2.20 / 2.52

2.20 / 2.52

2.20 / 2.52

2.20 / 2.52

22 + 22 + 22 + 22 + 25

2.20 / 2.51

2.20 / 2.51

2.20 / 2.51

2.20 / 2.51

2.50 / 2.85

22 + 22 + 22 + 22 + 35

2.20 / 2.52

2.20 / 2.52

2.20 / 2.52

2.20 / 2.52

3.50 / 4.01

2.20 / 2.53

2.20 / 2.53

2.20 / 2.53

2.20 / 2.53

22 + 35 + 35 + 71

1.89 / 2.16

3.01 / 3.44

3.01 / 3.44

6.10 / 6.97

22 + 22 + 22 + 25

2.20 / 2.51

2.20 / 2.51

2.20 / 2.51

2.50 / 2.86

22 + 35 + 50 + 50

1.96 / 2.24

3.12 / 3.57

4.46 / 5.10

4.46 / 5.10

22 + 22 + 22 + 35

2.20 / 2.50

2.20 / 2.50

2.20 / 2.50

3.50 / 3.99

22 + 35 + 50 + 60

1.84 / 2.11

2.93 / 3.35

4.19 / 4.79

5.03 / 5.75

22 + 22 + 22 + 22 + 50

2.20 / 2.52

2.20 / 2.52

2.20 / 2.52

2.20 / 2.52

5.00 / 5.72

22 + 22 + 22 + 50

2.20 / 2.52

2.20 / 2.52

2.20 / 2.52

5.00 / 5.73

22 + 35 + 50 + 71

5.58 / 6.38

22 + 22 + 22 + 22 + 60

2.08 / 2.38

2.08 / 2.38

2.08 / 2.38

2.08 / 2.38

5.68 / 6.49

22 + 22 + 22 + 22 + 71

1.94 / 2.21

1.94 / 2.21

1.94 / 2.21

1.94 / 2.21

6.25 / 7.14

22 + 22 + 22 + 25 + 25

2.20 / 2.52

2.20 / 2.52

2.20 / 2.52

2.50 / 2.87

2.50 / 2.87

22 + 22 + 22 + 25 + 35

2.20 / 2.51

2.20 / 2.51

2.20 / 2.51

2.50 / 2.86

3.50 / 4.00

2.75 / 3.15

3.93 / 4.49

22 + 22 + 22 + 60

2.20 / 2.51

2.20 / 2.51

2.20 / 2.51

6.00 / 6.86

22 + 35 + 60 + 60

1.74 / 1.99

2.77 / 3.16

4.75 / 5.42

4.75 / 5.42

22 + 22 + 22 + 71

2.20 / 2.52

2.20 / 2.52

2.20 / 2.52

7.10 / 8.14

22 + 50 + 50 + 50

1.79 / 2.05

4.07 / 4.65

4.07 / 4.65

4.07 / 4.65

22 + 22 + 22 + 100 1.86 / 2.12

1.86 / 2.12

1.86 / 2.12

8.43 / 9.64

22 + 50 + 50 + 60

1.69 / 1.93

3.85 / 4.40

3.85 / 4.40

4.62 / 5.27

22 + 22 + 22 + 25 + 50

2.18 / 2.50

2.18 / 2.50

2.18 / 2.50

2.48 / 2.84

4.96 / 5.67

2.20 / 2.50

2.20 / 2.50

2.50 / 2.85

2.50 / 2.85

25 + 25 + 25 + 25

2.50 / 2.85

2.50 / 2.85

2.50 / 2.85

2.50 / 2.85

22 + 22 + 22 + 25 + 60

2.04 / 2.33

2.04 / 2.33

2.04 / 2.33

2.32 / 2.65

5.56 / 6.36

22 + 22 + 22 + 25 + 71

1.90 / 2.17

1.90 / 2.17

1.90 / 2.17

2.16 / 2.47

6.14 / 7.01

22 + 22 + 22 + 35 + 35

2.20 / 2.51

2.20 / 2.51

2.20 / 2.51

3.50 / 3.99

3.50 / 3.99

22 + 22 + 25 + 25 22 + 22 + 25 + 35

2.20 / 2.52

2.20 / 2.52

2.50 / 2.86

3.50 / 4.00

22 + 22 + 25 + 50

2.20 / 2.51

2.20 / 2.51

2.50 / 2.86

5.00 / 5.71

22 + 22 + 25 + 60

2.20 / 2.51

2.20 / 2.51

2.50 / 2.85

6.00 / 6.84

22 + 22 + 25 + 71

2.20 / 2.51

2.20 / 2.51

2.50 / 2.86

7.10 / 8.11

22 + 22 + 25 + 100 1.82 / 2.08

1.82 / 2.08

2.07 / 2.37

8.28 / 9.47

22 + 22 + 35 + 35

2.20 / 2.51

2.20 / 2.51

3.50 / 3.99

3.50 / 3.99

22 + 22 + 35 + 50

2.20 / 2.51

2.20 / 2.51

3.50 / 3.99

5.00 / 5.70

22 + 22 + 35 + 60

2.20 / 2.52

2.20 / 2.52

3.50 / 4.00

6.00 / 6.86

22 + 22 + 35 + 71

2.05 / 2.35

2.05 / 2.35

3.27 / 3.73

6.63 / 7.57

22 + 22 + 35 + 100 1.72 / 1.97

1.72 / 1.97

2.74 / 3.13

7.82 / 8.94

22 + 22 + 50 + 50

2.14 / 2.44

2.14 / 2.44

4.86 / 5.56

4.86 / 5.56

22 + 22 + 50 + 60

2.00 / 2.29

2.00 / 2.29

4.55 / 5.19

5.45 / 6.23

22 + 22 + 50 + 71

1.87 / 2.13

1.87 / 2.13

4.24 / 4.85

6.02 / 6.88

22 + 22 + 60 + 60

1.88 / 2.15

1.88 / 2.15

5.12 / 5.85

5.12 / 5.85

22 + 22 + 60 + 71

25 + 25 + 25 + 35

1.76 / 2.01

4.80 / 5.49

2.20 / 2.52

2.50 / 2.86

2.50 / 2.86

2.50 / 2.86

22 + 25 + 25 + 35

2.20 / 2.51

2.50 / 2.85

2.50 / 2.85

3.50 / 3.99

22 + 25 + 25 + 50

2.20 / 2.51

2.50 / 2.85

2.50 / 2.85

5.00 / 5.70

22 + 25 + 25 + 60

2.20 / 2.52

2.50 / 2.86

2.50 / 2.86

6.00 / 6.86

2.50 / 2.86

2.50 / 2.86

5.00 / 5.72

22 + 22 + 22 + 35 + 50

2.04 / 2.33

2.04 / 2.33

2.04 / 2.33

3.25 / 3.71

4.64 / 5.30

25 + 25 + 25 + 60

2.50 / 2.85

2.50 / 2.85

2.50 / 2.85

6.00 / 6.84

22 + 22 + 22 + 35 + 60

1.91 / 2.19

1.91 / 2.19

1.91 / 2.19

3.04 / 3.48

5.22 / 5.96

25 + 25 + 25 + 71

2.40 / 2.74

2.40 / 2.74

2.40 / 2.74

6.81 / 7.78

22 + 22 + 22 + 35 + 71

1.79 / 2.05

1.79 / 2.05

1.79 / 2.05

2.85 / 3.26

5.78 / 6.60

8.00 / 9.14

22 + 22 + 22 + 50 + 50

1.86 / 2.12

1.86 / 2.12

1.86 / 2.12

4.22 / 4.82

4.22 / 4.82

22 + 22 + 22 + 50 + 60

1.75 / 2.00

1.75 / 2.00

1.75 / 2.00

3.98 / 4.55

4.77 / 5.45

2.20 / 2.51

2.50 / 2.86

2.50 / 2.86

2.50 / 2.86

25 + 25 + 25 + 100 2.00 / 2.29

2.45 / 2.80

6.95 / 7.94

22 + 25 + 25 + 100 1.79 / 2.05

2.03 / 2.33

2.03 / 2.33

8.14 / 9.30

22 + 25 + 35 + 35

2.20 / 2.52

2.50 / 2.86

3.50 / 4.01

3.50 / 4.01

22 + 25 + 35 + 50

2.20 / 2.52

2.50 / 2.86

3.50 / 4.00

5.00 / 5.72

22 + 25 + 35 + 60 22 + 25 + 35 + 71

2.17 / 2.48 2.01 / 2.30

2.46 / 2.82 2.29 / 2.61

3.45 / 3.94 3.20 / 3.66

5.92 / 6.76 6.50 / 7.42

22 + 25 + 35 + 100 1.69 / 1.93

1.92 / 2.20

2.69 / 3.08

7.69 / 8.79

22 + 25 + 50 + 50

2.10 / 2.39

2.38 / 2.72

4.76 / 5.44

4.76 / 5.44

22 + 25 + 50 + 60

1.96 / 2.24

2.23 / 2.55

4.46 / 5.10

5.35 / 6.11

22 + 25 + 50 + 71

1.83 / 2.10

2.08 / 2.38

4.17 / 4.76

2.00 / 2.29

2.00 / 2.29

25 + 25 + 35 + 35

2.50 / 2.85

2.50 / 2.85

3.50 / 4.00

3.50 / 4.00

22 + 22 + 25 + 25 + 25

2.20 / 2.51

25 + 25 + 35 + 50

2.50 / 2.85

2.50 / 2.85

3.50 / 3.99

5.00 / 5.70

22 + 22 + 25 + 25 + 35

2.20 / 2.51

2.20 / 2.51

2.50 / 2.85

2.50 / 2.85

3.50 / 3.99

25 + 25 + 35 + 60

2.41 / 2.76

2.41 / 2.76

3.38 / 3.86

5.79 / 6.62

22 + 22 + 25 + 25 + 50

2.14 / 2.44

2.14 / 2.44

2.43 / 2.78

2.43 / 2.78

4.86 / 5.56

6.37 / 7.28

22 + 22 + 25 + 25 + 60

2.00 / 2.29

2.00 / 2.29

2.27 / 2.60

2.27 / 2.60

5.45 / 6.23

22 + 22 + 25 + 25 + 71

1.87 / 2.13

1.87 / 2.13

2.12 / 2.42

2.12 / 2.42

6.02 / 6.88

2.20 / 2.52

2.50 / 2.86

3.50 / 4.00

3.50 / 4.00

25 + 25 + 35 + 71

2.24 / 2.56

2.24 / 2.56

3.14 / 3.59

25 + 25 + 35 + 100 1.89 / 2.16

1.89 / 2.16

2.65 / 3.03

7.57 / 8.65

22 + 22 + 25 + 35 + 35

2.20 / 2.52

25 + 25 + 50 + 50

2.33 / 2.67

2.33 / 2.67

4.67 / 5.33

4.67 / 5.33

22 + 22 + 25 + 35 + 50

2.00 / 2.29

2.00 / 2.29

2.27 / 2.60

3.18 / 3.64

4.55 / 5.19

25 + 25 + 50 + 60

2.19 / 2.50

2.19 / 2.50

4.38 / 5.00

5.25 / 6.00

22 + 22 + 25 + 35 + 60

1.88 / 2.15

1.88 / 2.15

2.13 / 2.44

2.99 / 3.41

5.12 / 5.85

5.81 / 6.64

22 + 22 + 25 + 35 + 71

1.76 / 2.01

1.76 / 2.01

2.00 / 2.29

2.80 / 3.20

5.68 / 6.49

22 + 22 + 25 + 50 + 50

1.82 / 2.08

1.82 / 2.08

2.07 / 2.37

4.14 / 4.73

4.14 / 4.73

1.72 / 1.97

1.96 / 2.23

3.91 / 4.47

4.69 / 5.36

2.05 / 2.34

2.05 / 2.34

4.09 / 4.68

25 + 25 + 60 + 60

2.06 / 2.35

2.06 / 2.35

4.94 / 5.65

4.94 / 5.65

22 + 22 + 25 + 50 + 60

1.72 / 1.97

25 + 25 + 60 + 71

1.93 / 2.21

1.93 / 2.21

4.64 / 5.30

5.49 / 6.28

22 + 22 + 35 + 35 + 35

2.07 / 2.36

2.07 / 2.36

3.29 / 3.76

3.29 / 3.76

3.29 / 3.76

25 + 35 + 35 + 35

2.50 / 2.87

3.50 / 4.01

3.50 / 4.01

3.50 / 4.01

22 + 22 + 35 + 35 + 50

1.88 / 2.15

1.88 / 2.15

2.99 / 3.41

2.99 / 3.41

4.27 / 4.88

4.83 / 5.52

22 + 22 + 35 + 35 + 60

1.77 / 2.02

1.77 / 2.02

2.82 / 3.22

2.82 / 3.22

4.83 / 5.52

22 + 22 + 35 + 35 + 71

1.66 / 1.90

1.66 / 1.90

2.65 / 3.03

2.65 / 3.03

5.37 / 6.14

22 + 22 + 35 + 50 + 50

1.72 / 1.97

1.72 / 1.97

2.74 / 3.13

3.91 / 4.47

3.91 / 4.47

22 + 25 + 25 + 25 + 25

2.20 / 2.51

2.50 / 2.85

2.50 / 2.85

2.50 / 2.85

2.50 / 2.85

2.50 / 2.86

2.50 / 2.86

2.50 / 2.86

3.50 / 4.00

25 + 35 + 35 + 60 2.45 / 2.80

3.50 / 4.01

2.50 / 2.86

25 + 35 + 35 + 50

2.15 / 2.46

2.50 / 2.86

5.68 / 6.49

22 + 25 + 25 + 25

22 + 25 + 25 + 71

2.50 / 2.86

25 + 25 + 25 + 50

25 + 25 + 50 + 71 1.76 / 2.01

2.50 / 2.86

5.92 / 6.76

25 + 35 + 35 + 71

2.41 / 2.76

3.38 / 3.86

3.38 / 3.86

2.26 / 2.58

3.16 / 3.61

3.16 / 3.61

5.42 / 6.19

2.11 / 2.41

2.95 / 3.37

2.95 / 3.37

5.99 / 6.84

25 + 35 + 50 + 50

2.19 / 2.50

3.06 / 3.50

4.38 / 5.00

4.38 / 5.00

22 + 25 + 25 + 25 + 35

2.20 / 2.52

25 + 35 + 50 + 60

2.06 / 2.35

2.88 / 3.29

4.12 / 4.71

4.94 / 5.65

22 + 25 + 25 + 25 + 50

2.10 / 2.39

2.38 / 2.72

2.38 / 2.72

2.38 / 2.72

4.76 / 5.44

22 + 25 + 25 + 25 + 60

1.96 / 2.24

2.23 / 2.55

2.23 / 2.55

2.23 / 2.55

5.35 / 6.11

22 + 25 + 25 + 25 + 71

1.83 / 2.10

2.08 / 2.38

2.08 / 2.38

2.08 / 2.38

5.92 / 6.76

22 + 25 + 25 + 35 + 35

2.17 / 2.48

2.46 / 2.82

2.46 / 2.82

3.45 / 3.94

3.45 / 3.94

22 + 25 + 25 + 35 + 50

1.96 / 2.24

2.23 / 2.55

2.23 / 2.55

3.12 / 3.57

4.46 / 5.10

22 + 25 + 25 + 35 + 60

1.84 / 2.11

2.10 / 2.40

2.10 / 2.40

2.93 / 3.35

5.03 / 5.75

22 + 25 + 25 + 35 + 71

1.73 / 1.98

1.97 / 2.25

1.97 / 2.25

2.75 / 3.15

5.58 / 6.38

22 + 25 + 25 + 50 + 50

1.79 / 2.05

2.03 / 2.33

2.03 / 2.33

4.07 / 4.65

4.07 / 4.65

25 + 35 + 50 + 71 25 + 35 + 60 + 60 25 + 50 + 50 + 50

1.93 / 2.21

2.71 / 3.09

3.87 / 4.42

5.49 / 6.28

1.94 / 2.22

2.72 / 3.11

4.67 / 5.33

4.67 / 5.33

2.00 / 2.29

4.00 / 4.57

4.00 / 4.57

4.00 / 4.57

25 + 50 + 50 + 60

1.89 / 2.16

3.78 / 4.32

3.78 / 4.32

4.54 / 5.19

35 + 35 + 35 + 35

3.50 / 4.00

3.50 / 4.00

3.50 / 4.00

3.50 / 4.00

35 + 35 + 35 + 50

3.16 / 3.61

3.16 / 3.61

3.16 / 3.61

4.52 / 5.16

22 + 25 + 25 + 50 + 60

1.69 / 1.93

1.92 / 2.20

1.92 / 2.20

3.85 / 4.40

4.62 / 5.27

35 + 35 + 35 + 60

2.97 / 3.39

2.97 / 3.39

2.97 / 3.39

5.09 / 5.82

22 + 25 + 35 + 35 + 35

2.03 / 2.32

2.30 / 2.63

3.22 / 3.68

3.22 / 3.68

3.22 / 3.68

22 + 25 + 35 + 35 + 50

1.84 / 2.11

2.10 / 2.40

2.93 / 3.35

2.93 / 3.35

4.19 / 4.79

22 + 25 + 35 + 35 + 60

1.74 / 1.99

1.98 / 2.26

2.77 / 3.16

2.77 / 3.16

4.75 / 5.42

22 + 25 + 35 + 50 + 50

1.69 / 1.93

1.92 / 2.20

2.69 / 3.08

3.85 / 4.40

3.85 / 4.40

22 + 35 + 35 + 35 + 35

1.90 / 2.17

3.02 / 3.46

3.02 / 3.46

3.02 / 3.46

3.02 / 3.46

22 + 35 + 35 + 35 + 50

1.74 / 1.99

2.77 / 3.16

2.77 / 3.16

2.77 / 3.16

3.95 / 4.52

22 + 25 + 60 + 60

1.84 / 2.10

2.10 / 2.40

5.03 / 5.75

5.03 / 5.75

35 + 35 + 35 + 71

22 + 25 + 60 + 71

1.73 / 1.98

1.97 / 2.25

4.72 / 5.39

5.58 / 6.38

35 + 35 + 50 + 50

2.88 / 3.29

2.88 / 3.29

4.12 / 4.71

4.12 / 4.71

22 + 35 + 35 + 35

2.20 / 2.51

3.50 / 4.00

3.50 / 4.00

3.50 / 4.00

35 + 35 + 50 + 60

2.72 / 3.11

2.72 / 3.11

3.89 / 4.44

4.67 / 5.33

4.93 / 5.63

35 + 50 + 50 + 50

2.65 / 3.03

3.78 / 4.32

3.78 / 4.32

3.78 / 4.32

22 + 35 + 35 + 50

Page 48

2.17 / 2.48

3.45 / 3.94

3.45 / 3.94

2.78 / 3.18

2.78 / 3.18

2.78 / 3.18

5.65 / 6.45

Unit G

Unit H

5 ROOMS

22 + 22 + 22 + 22

1.73 / 1.98

Unit F

Page 49


Indoor unit combination

Indoor unit combination

Cooling / Heating Capacity (kW)

Cooling / Heating Capacity (kW)

Unit A

Unit B

Unit C

Unit D

Unit E

Unit A

Unit B

Unit C

Unit D

Unit E

Unit F

25 + 25 + 25 + 25 + 25

2.50 / 2.86

2.50 / 2.86

2.50 / 2.86

2.50 / 2.86

2.50 / 2.86

22 + 25 + 25 + 25 + 25 + 35

1.96 / 2.24

2.23 / 2.55

2.23 / 2.55

2.23 / 2.55

2.23 / 2.55

3.12 / 3.57

25 + 25 + 25 + 25 + 35

2.50 / 2.85

2.50 / 2.85

2.50 / 2.85

2.50 / 2.85

3.50 / 3.99

22 + 25 + 25 + 25 + 25 + 50

1.79 / 2.05

2.03 / 2.33

2.03 / 2.33

2.03 / 2.33

2.03 / 2.33

4.07 / 4.65

Unit F

Unit G

Unit H

25 + 25 + 25 + 25 + 50

2.33 / 2.67

2.33 / 2.67

2.33 / 2.67

2.33 / 2.67

4.67 / 5.33

22 + 25 + 25 + 25 + 25 + 60

1.69 / 1.93

1.92 / 2.20

1.92 / 2.20

1.92 / 2.20

1.92 / 2.20

4.62 / 5.27

25 + 25 + 25 + 25 + 60

2.19 / 2.50

2.19 / 2.50

2.19 / 2.50

2.19 / 2.50

5.25 / 6.00

22 + 25 + 25 + 25 + 35 + 35

1.84 / 2.11

2.10 / 2.40

2.10 / 2.40

2.10 / 2.40

2.93 / 3.35

2.93 / 3.35

25 + 25 + 25 + 25 + 71

2.05 / 2.34

2.05 / 2.34

2.05 / 2.34

2.05 / 2.34

5.81 / 6.64

22 + 25 + 25 + 25 + 35 + 50

1.69 / 1.93

1.92 / 2.20

1.92 / 2.20

1.92 / 2.20

2.69 / 3.08

3.85 / 4.40

25 + 25 + 25 + 35 + 35

2.41 / 2.76

2.41 / 2.76

2.41 / 2.76

3.38 / 3.86

3.38 / 3.86

22 + 25 + 25 + 35 + 35 + 35

1.74 / 1.99

1.98 / 2.26

1.98 / 2.26

2.77 / 3.16

2.77 / 3.16

2.77 / 3.16

25 + 25 + 25 + 35 + 50

2.19 / 2.50

2.19 / 2.50

2.19 / 2.50

3.06 / 3.50

4.38 / 5.00

25 + 25 + 25 + 25 + 25 + 25

2.33 / 2.67

2.33 / 2.67

2.33 / 2.67

2.33 / 2.67

2.33 / 2.67

2.33 / 2.67

25 + 25 + 25 + 35 + 60

2.06 / 2.35

2.06 / 2.35

2.06 / 2.35

2.88 / 3.29

4.94 / 5.65

25 + 25 + 25 + 25 + 25 + 35

2.19 / 2.50

2.19 / 2.50

2.19 / 2.50

2.19 / 2.50

2.19 / 2.50

3.06 / 3.50

25 + 25 + 25 + 35 + 71

1.93 / 2.21

1.93 / 2.21

1.93 / 2.21

2.71 / 3.09

5.49 / 6.28

25 + 25 + 25 + 25 + 25 + 50

2.00 / 2.29

2.00 / 2.29

2.00 / 2.29

2.00 / 2.29

2.00 / 2.29

4.00 / 4.57

25 + 25 + 25 + 50 + 50

2.00 / 2.29

2.00 / 2.29

2.00 / 2.29

4.00 / 4.57

4.00 / 4.57

25 + 25 + 25 + 25 + 25 + 60

1.89 / 2.16

1.89 / 2.16

1.89 / 2.16

1.89 / 2.16

1.89 / 2.16

4.54 / 5.19

Unit G

25 + 25 + 25 + 50 + 60

1.89 / 2.16

1.89 / 2.16

1.89 / 2.16

3.78 / 4.32

4.54 / 5.19

25 + 25 + 25 + 25 + 35 + 35

2.06 / 2.35

2.06 / 2.35

2.06 / 2.35

2.06 / 2.35

2.88 / 3.29

2.88 / 3.29

25 + 25 + 35 + 35 + 35

2.26 / 2.58

2.26 / 2.58

3.16 / 3.61

3.16 / 3.61

3.16 / 3.61

25 + 25 + 25 + 25 + 35 + 50

1.89 / 2.16

1.89 / 2.16

1.89 / 2.16

1.89 / 2.16

2.65 / 3.03

3.78 / 4.32

25 + 25 + 35 + 35 + 50

2.06 / 2.35

2.06 / 2.35

2.88 / 3.29

2.88 / 3.29

4.12 / 4.71

25 + 25 + 25 + 35 + 35 + 35

1.94 / 2.22

1.94 / 2.22

1.94 / 2.22

2.72 / 3.11

2.72 / 3.11

2.72 / 3.11

25 + 25 + 35 + 35 + 60

1.94 / 2.22

1.94 / 2.22

2.72 / 3.11

2.72 / 3.11

4.67 / 5.33

25 + 25 + 35 + 50 + 50

1.89 / 2.16

1.89 / 2.16

2.65 / 3.03

3.78 / 4.32

3.78 / 4.32

25 + 35 + 35 + 35 + 35

2.12 / 2.42

2.97 / 3.39

2.97 / 3.39

2.97 / 3.39

2.97 / 3.39

25 + 35 + 35 + 35 + 50

1.94 / 2.22

2.72 / 3.11

2.72 / 3.11

2.72 / 3.11

3.89 / 4.44

35 + 35 + 35 + 35 + 35

2.80 / 3.20

2.80 / 3.20

2.80 / 3.20

2.80 / 3.20

2.80 / 3.20

22 + 22 + 22 + 22 + 22 + 22 + 22

2.00 / 2.29

2.00 / 2.29

2.00 / 2.29

2.00 / 2.29

2.00 / 2.29

2.00 / 2.29

2.00 / 2.29

22 + 22 + 22 + 22 + 22 + 22 + 25

1.96 / 2.24

1.96 / 2.24

1.96 / 2.24

1.96 / 2.24

1.96 / 2.24

1.96 / 2.24

2.23 / 2.55

Unit H

7 ROOMS

6 ROOMS 22 + 22 + 22 + 22 + 22 + 22

2.20 / 2.52

2.20 / 2.52

2.20 / 2.52

2.20 / 2.52

2.20 / 2.52

2.20 / 2.52

22 + 22 + 22 + 22 + 22 + 22 + 35

1.84 / 2.11

1.84 / 2.11

1.84 / 2.11

1.84 / 2.11

1.84 / 2.11

1.84 / 2.11

2.93 / 3.35

22 + 22 + 22 + 22 + 22 + 25

2.20 / 2.51

2.20 / 2.51

2.20 / 2.51

2.20 / 2.51

2.20 / 2.51

2.50 / 2.85

22 + 22 + 22 + 22 + 22 + 22 + 50

1.69 / 1.93

1.69 / 1.93

1.69 / 1.93

1.69 / 1.93

1.69 / 1.93

1.69 / 1.93

3.85 / 4.40

22 + 22 + 22 + 22 + 22 + 35

2.12 / 2.43

2.12 / 2.43

2.12 / 2.43

2.12 / 2.43

2.12 / 2.43

3.38 / 3.86

22 + 22 + 22 + 22 + 22 + 25 + 25

1.93 / 2.20

1.93 / 2.20

1.93 / 2.20

1.93 / 2.20

1.93 / 2.20

2.19 / 2.50

2.19 / 2.50

22 + 22 + 22 + 22 + 22 + 50

1.93 / 2.20

1.93 / 2.20

1.93 / 2.20

1.93 / 2.20

1.93 / 2.20

4.38 / 5.00

22 + 22 + 22 + 22 + 22 + 25 + 35

1.81 / 2.07

1.81 / 2.07

1.81 / 2.07

1.81 / 2.07

1.81 / 2.07

2.06 / 2.35

2.88 / 3.29

22 + 22 + 22 + 22 + 22 + 60

1.81 / 2.07

1.81 / 2.07

1.81 / 2.07

1.81 / 2.07

1.81 / 2.07

4.94 / 5.65

22 + 22 + 22 + 22 + 22 + 25 + 50

1.66 / 1.90

1.66 / 1.90

1.66 / 1.90

1.66 / 1.90

1.66 / 1.90

1.89 / 2.16

3.78 / 4.32

22 + 22 + 22 + 22 + 22 + 71

1.70 / 1.94

1.70 / 1.94

1.70 / 1.94

1.70 / 1.94

1.70 / 1.94

5.49 / 6.28

22 + 22 + 22 + 22 + 22 + 35 + 35

1.71 / 1.96

1.71 / 1.96

1.71 / 1.96

1.71 / 1.96

1.71 / 1.96

2.72 / 3.11

2.72 / 3.11

22 + 22 + 22 + 22 + 25 + 25

2.20 / 2.52

2.20 / 2.52

2.20 / 2.52

2.20 / 2.52

2.50 / 2.86

2.50 / 2.86

22 + 22 + 22 + 22 + 25 + 25 + 25

1.89 / 2.16

1.89 / 2.16

1.89 / 2.16

1.89 / 2.16

2.15 / 2.45

2.15 / 2.45

2.15 / 2.45

22 + 22 + 22 + 22 + 25 + 35

2.08 / 2.38

2.08 / 2.38

2.08 / 2.38

2.08 / 2.38

2.36 / 2.70

3.31 / 3.78

22 + 22 + 22 + 22 + 25 + 25 + 35

1.78 / 2.03

1.78 / 2.03

1.78 / 2.03

1.78 / 2.03

2.02 / 2.31

2.02 / 2.31

2.83 / 3.24

22 + 22 + 22 + 22 + 25 + 50

1.89 / 2.16

1.89 / 2.16

1.89 / 2.16

1.89 / 2.16

2.15 / 2.45

4.29 / 4.91

22 + 22 + 22 + 22 + 25 + 35 + 35

1.68 / 1.92

1.68 / 1.92

1.68 / 1.92

1.68 / 1.92

1.91 / 2.19

2.68 / 3.06

2.68 / 3.06

22 + 22 + 22 + 22 + 25 + 60

1.78 / 2.03

1.78 / 2.03

1.78 / 2.03

1.78 / 2.03

2.02 / 2.31

4.86 / 5.55

22 + 22 + 22 + 25 + 25 + 25 + 25

1.86 / 2.12

1.86 / 2.12

1.86 / 2.12

2.11 / 2.41

2.11 / 2.41

2.11 / 2.41

2.11 / 2.41

22 + 22 + 22 + 22 + 25 + 71

1.67 / 1.91

1.67 / 1.91

1.67 / 1.91

1.67 / 1.91

1.90 / 2.17

5.40 / 6.17

22 + 22 + 22 + 25 + 25 + 25 + 35

1.75 / 2.00

1.75 / 2.00

1.75 / 2.00

1.99 / 2.27

1.99 / 2.27

1.99 / 2.27

2.78 / 3.18

22 + 22 + 22 + 22 + 35 + 35

1.95 / 2.23

1.95 / 2.23

1.95 / 2.23

1.95 / 2.23

3.10 / 3.54

3.10 / 3.54

22 + 22 + 25 + 25 + 25 + 25 + 25

1.82 / 2.08

1.82 / 2.08

2.07 / 2.37

2.07 / 2.37

2.07 / 2.37

2.07 / 2.37

2.07 / 2.37

22 + 22 + 22 + 22 + 35 + 50

1.78 / 2.03

1.78 / 2.03

1.78 / 2.03

1.78 / 2.03

2.83 / 3.24

4.05 / 4.62

22 + 22 + 25 + 25 + 25 + 25 + 35

1.72 / 1.97

1.72 / 1.97

1.96 / 2.23

1.96 / 2.23

1.96 / 2.23

1.96 / 2.23

2.74 / 3.13

22 + 22 + 22 + 22 + 35 + 60

1.68 / 1.92

1.68 / 1.92

1.68 / 1.92

1.68 / 1.92

2.68 / 3.06

4.59 / 5.25

22 + 25 + 25 + 25 + 25 + 25 + 25

1.79 / 2.05

2.03 / 2.33

2.03 / 2.33

2.03 / 2.33

2.03 / 2.33

2.03 / 2.33

2.03 / 2.33

22 + 22 + 22 + 25 + 25 + 25

2.18 / 2.50

2.18 / 2.50

2.18 / 2.50

2.48 / 2.84

2.48 / 2.84

2.48 / 2.84

22 + 25 + 25 + 25 + 25 + 25 + 35

1.69 / 1.93

1.92 / 2.20

1.92 / 2.20

1.92 / 2.20

1.92 / 2.20

1.92 / 2.20

2.69 / 3.08

22 + 22 + 22 + 25 + 25 + 35

2.04 / 2.33

2.04 / 2.33

2.04 / 2.33

2.32 / 2.65

2.32 / 2.65

3.25 / 3.71

25 + 25 + 25 + 25 + 25 + 25 + 25

2.00 / 2.29

2.00 / 2.29

2.00 / 2.29

2.00 / 2.29

2.00 / 2.29

2.00 / 2.29

2.00 / 2.29

22 + 22 + 22 + 25 + 25 + 50

1.86 / 2.12

1.86 / 2.12

1.86 / 2.12

2.11 / 2.41

2.11 / 2.41

4.22 / 4.82

25 + 25 + 25 + 25 + 25 + 25 + 35

1.89 / 2.16

1.89 / 2.16

1.89 / 2.16

1.89 / 2.16

1.89 / 2.16

1.89 / 2.16

2.65 / 3.03

22 + 22 + 22 + 25 + 25 + 60

1.75 / 2.00

1.75 / 2.00

1.75 / 2.00

1.99 / 2.27

1.99 / 2.27

4.77 / 5.45

22 + 22 + 22 + 25 + 35 + 35

1.91 / 2.19

1.91 / 2.19

1.91 / 2.19

2.17 / 2.48

3.04 / 3.48

3.04 / 3.48

22 + 22 + 22 + 25 + 35 + 50

1.75 / 2.00

1.75 / 2.00

1.75 / 2.00

1.99 / 2.27

2.78 / 3.18

3.98 / 4.55

22 + 22 + 22 + 35 + 35 + 35

1.80 / 2.06

1.80 / 2.06

1.80 / 2.06

2.87 / 3.27

2.87 / 3.27

2.87 / 3.27

22 + 22 + 25 + 25 + 25 + 25

2.14 / 2.44

2.14 / 2.44

2.43 / 2.78

2.43 / 2.78

2.43 / 2.78

2.43 / 2.78

8 ROOMS

22 + 22 + 25 + 25 + 25 + 35

2.00 / 2.29

2.00 / 2.29

2.27 / 2.60

2.27 / 2.60

2.27 / 2.60

3.18 / 3.64

22 + 22 + 22 + 22 + 22 + 22 + 22 + 22

1.75 / 2.00

1.75 / 2.00

1.75 / 2.00

1.75 / 2.00

1.75 / 2.00

1.75 / 2.00

1.75 / 2.00

1.75 / 2.00

22 + 22 + 25 + 25 + 25 + 50

1.82 / 2.08

1.82 / 2.08

2.07 / 2.37

2.07 / 2.37

2.07 / 2.37

4.14 / 4.73

22 + 22 + 22 + 22 + 22 + 22 + 22 + 25

1.72 / 1.97

1.72 / 1.97

1.72 / 1.97

1.72 / 1.97

1.72 / 1.97

1.72 / 1.97

1.72 / 1.97

1.96 / 2.23

22 + 22 + 25 + 25 + 25 + 60

1.72 / 1.97

1.72 / 1.97

1.96 / 2.23

1.96 / 2.23

1.96 / 2.23

4.69 / 5.36

22 + 22 + 22 + 22 + 22 + 22 + 25 + 25

1.69 / 1.93

1.69 / 1.93

1.69 / 1.93

1.69 / 1.93

1.69 / 1.93

1.69 / 1.93

1.92 / 2.20

1.92 / 2.20

22 + 22 + 25 + 25 + 35 + 35

1.88 / 2.15

1.88 / 2.15

2.13 / 2.44

2.13 / 2.44

2.99 / 3.41

2.99 / 3.41

22 + 22 + 22 + 22 + 22 + 25 + 25 + 25

1.66 / 1.90

1.66 / 1.90

1.66 / 1.90

1.66 / 1.90

1.66 / 1.90

1.89 / 2.16

1.89 / 2.16

1.89 / 2.16

22 + 22 + 25 + 25 + 35 + 50

1.72 / 1.97

1.72 / 1.97

1.96 / 2.23

1.96 / 2.23

2.74 / 3.13

3.91 / 4.47

22 + 22 + 25 + 35 + 35 + 35

1.70 / 2.02

1.70 / 2.02

2.00 / 2.30

2.82 / 3.22

2.82 / 3.22

2.82 / 3.22

22 + 22 + 35 + 35 + 35 + 35

1.67 / 1.91

1.67 / 1.91

2.66 / 3.04

2.66 / 3.04

2.66 / 3.04

2.66 / 3.04

22 + 25 + 25 + 25 + 25 + 25

2.10 / 2.39

2.38 / 2.72

2.38 / 2.72

2.38 / 2.72

2.38 / 2.72

2.38 / 2.72

Page 50

Page 51


MXZ-8B160YA 1 Outdoor Unit Indoor unit combination

Indoor unit combination

Up to 8 Indoor Units Cooling / Heating Capacity (kW) Unit A

Unit B

Unit C

1 ROOM

Unit D

Cooling / Heating Capacity (kW)

Indoor unit combination

Cooling / Heating Capacity (kW)

Indoor unit combination

Unit A

Unit B

Unit C

Unit A

Unit B

Unit C

Unit A

Unit B

Unit C

Unit D

22 + 25 + 25

2.20 / 2.57

2.50 / 2.92

2.50 / 2.92

35 + 60 + 71

2.95 / 3.80

5.06 / 6.51

5.99 / 7.70

22 + 25 + 35 + 71

2.01 / 2.59

2.29 / 2.94

3.20 / 4.12

6.50 / 8.35

22 + 25 + 35

2.20 / 2.55

2.50 / 2.90

3.50 / 4.05

35 + 60 + 100

2.51 / 3.23

4.31 / 5.54

7.18 / 9.23

22 + 25 + 35 + 100 1.69 / 2.18

1.92 / 2.47

2.69 / 3.46

7.69 / 9.89

Unit D

Unit D

Cooling / Heating Capacity (kW)

22 + 25 + 50

2.20 / 2.56

2.50 / 2.91

5.00 / 5.82

35 + 71 + 71

2.77 / 3.56

5.62 / 7.22

5.62 / 7.22

22 + 25 + 50 + 50

2.10 / 2.69

2.38 / 3.06

4.76 / 6.12

4.76 / 6.12

22 + 25 + 60

2.20 / 2.55

2.50 / 2.90

6.00 / 6.95

50 + 50 + 50

4.67 / 6.00

4.67 / 6.00

4.67 / 6.00

22 + 25 + 50 + 60

1.96 / 2.52

2.23 / 2.87

4.46 / 5.73

5.35 / 6.88

50 + 50 + 60

4.38 / 5.63

4.38 / 5.63

5.25 / 6.75

22 + 25 + 50 + 71

1.83 / 2.36

2.08 / 2.68

4.17 / 5.36

5.92 / 7.61

50 + 50 + 71

4.09 / 5.26

4.09 / 5.26

5.81 / 7.47

22 + 25 + 50 + 100 1.56 / 2.01

1.78 / 2.28

3.55 / 4.57

7.11 / 9.14

22

2.20 / 3.30

22 + 25 + 71

2.20 / 2.55

2.50 / 2.90

7.10 / 8.24

25

2.50 / 3.60

22 + 25 + 100

2.10 / 2.69

2.38 / 3.06

9.52 / 12.24

35

3.50 / 4.00

22 + 35 + 35

2.20 / 2.56

3.50 / 4.07

3.50 / 4.07

50 + 50 + 100

3.50 / 4.50

3.50 / 4.50

7.00 / 9.00

22 + 25 + 60 + 60

1.84 / 2.37

2.10 / 2.69

5.03 / 6.47

5.03 / 6.47

50

5.00 / 7.20

22 + 35 + 50

2.20 / 2.55

3.50 / 4.06

5.00 / 5.79

50 + 60 + 60

4.12 / 5.29

4.94 / 6.35

4.94 / 6.35

22 + 25 + 60 + 71

1.73 / 2.22

1.97 / 2.53

4.72 / 6.07

5.58 / 7.18

60

6.00 / 7.90

22 + 35 + 60

2.20 / 2.56

3.50 / 4.07

6.00 / 6.97

50 + 60 + 71

3.87 / 4.97

4.64 / 5.97

5.49 / 7.06

22 + 25 + 71 + 71

1.63 / 2.10

1.85 / 2.38

5.26 / 6.76

5.26 / 6.76

71

7.10 / 8.60

22 + 35 + 71

2.20 / 2.56

3.50 / 4.07

7.10 / 8.26

50 + 71 + 71

3.65 / 4.69

5.18 / 6.66

5.18 / 6.66

22 + 35 + 35 + 35

2.20 / 2.55

3.50 / 4.05

3.50 / 4.05

3.50 / 4.05

10.00 / 11.20

22 + 35 + 100

1.96 / 2.52

3.12 / 4.01

8.92 / 11.46

60 + 60 + 60

4.67 / 6.00

4.67 / 6.00

4.67 / 6.00

22 + 35 + 35 + 50

2.17 / 2.79

3.45 / 4.44

3.45 / 4.44

4.93 / 6.34

22 + 50 + 50

2.20 / 2.56

5.00 / 5.82

5.00 / 5.82

60 + 60 + 71

4.40 / 5.65

4.40 / 5.65

5.20 / 6.69

22 + 35 + 35 + 60

2.03 / 2.61

3.22 / 4.14

3.22 / 4.14

5.53 / 7.11

22 + 50 + 60

2.20 / 2.55

5.00 / 5.80

6.00 / 6.95

60 + 71 + 71

4.16 / 5.35

4.92 / 6.33

4.92 / 6.33

22 + 35 + 35 + 71

1.89 / 2.43

3.01 / 3.87

3.01 / 3.87

6.10 / 7.84

2.20 / 2.55

22 + 50 + 71

2.15 / 2.77

4.90 / 6.29

6.95 / 8.94

22 + 35 + 35 + 100 1.60 / 2.06

2.55 / 3.28

2.55 / 3.28

7.29 / 9.38

22 + 35 + 50 + 50

1.96 / 2.52

3.12 / 4.01

4.46 / 5.73

4.46 / 5.73

22 + 35 + 50 + 60

1.84 / 2.37

2.93 / 3.77

4.19 / 5.39

5.03 / 6.47

100

2 ROOMS 22 + 22

2.20 / 2.55

22 + 25

2.20 / 2.57

2.50 / 2.93

22 + 50 + 100

1.79 / 2.30

4.07 / 5.23

8.14 / 10.47

22 + 35

2.20 / 2.55

3.50 / 4.05

22 + 60 + 60

2.17 / 2.79

5.92 / 7.61

5.92 / 7.61

4 ROOMS

22 + 50

2.20 / 2.57

5.00 / 5.83

22 + 60 + 71

2.01 / 2.59

5.49 / 7.06

6.50 / 8.35

22 + 22 + 22 + 22

2.20 / 2.55

2.20 / 2.55

2.20 / 2.55

2.20 / 2.55

22 + 35 + 50 + 71

1.73 / 2.22

2.75 / 3.54

3.93 / 5.06

5.58 / 7.18

22 + 60

2.20 / 2.55

6.00 / 6.95

22 + 60 + 100

1.69 / 2.18

4.62 / 5.93

7.69 / 9.89

22 + 22 + 22 + 25

2.20 / 2.56

2.20 / 2.56

2.20 / 2.56

2.50 / 2.91

22 + 35 + 60 + 60

1.74 / 2.24

2.77 / 3.56

4.75 / 6.10

4.75 / 6.10

7.10 / 8.25

22 + 71 + 71

2.20 / 2.55

2.20 / 2.55

2.20 / 2.55

3.50 / 4.05

22 + 35 + 60 + 71

22 + 71

2.20 / 2.55

1.88 / 2.41

6.06 / 7.79

6.06 / 7.79

22 + 22 + 22 + 35

1.64 / 2.11

2.61 / 3.35

4.47 / 5.74

5.29 / 6.80

22 + 100

2.20 / 2.56 10.00 / 11.64

22 + 71 + 100

1.60 / 2.05

5.15 / 6.62

7.25 / 9.33

22 + 22 + 22 + 50

2.20 / 2.56

2.20 / 2.56

2.20 / 2.56

5.00 / 5.82

22 + 35 + 71 + 71

1.55 / 1.99

2.46 / 3.17

4.99 / 6.42

4.99 / 6.42

25 + 25

2.50 / 2.90

2.50 / 2.90

25 + 25 + 25

2.50 / 2.90

2.50 / 2.90

2.50 / 2.90

22 + 22 + 22 + 60

2.20 / 2.55

2.20 / 2.55

2.20 / 2.55

6.00 / 6.95

22 + 50 + 50 + 50

1.79 / 2.30

4.07 / 5.23

4.07 / 5.23

4.07 / 5.23

25 + 35

2.50 / 2.92

3.50 / 4.08

25 + 25 + 35

2.50 / 2.91

2.50 / 2.91

3.50 / 4.08

22 + 22 + 22 + 71

2.20 / 2.55

2.20 / 2.55

2.20 / 2.55

7.10 / 8.24

22 + 50 + 50 + 60

1.69 / 2.18

3.85 / 4.95

3.85 / 4.95

4.62 / 5.93

1.86 / 2.39

1.86 / 2.39

8.43 / 10.84

22 + 50 + 50 + 71

25 + 50

2.50 / 2.90

5.00 / 5.80

25 + 25 + 50

2.50 / 2.90

2.50 / 2.90

5.00 / 5.80

22 + 22 + 22 + 100 1.86 / 2.39

1.60 / 2.05

3.63 / 4.66

3.63 / 4.66

5.15 / 6.62

25 + 60

2.50 / 2.91

6.00 / 6.99

25 + 25 + 60

2.50 / 2.91

2.50 / 2.91

6.00 / 6.98

22 + 22 + 25 + 25

2.20 / 2.55

2.20 / 2.55

2.50 / 2.90

2.50 / 2.90

22 + 50 + 60 + 60

1.60 / 2.06

3.65 / 4.69

4.38 / 5.63

4.38 / 5.63

25 + 71

2.50 / 2.89

7.10 / 8.21

25 + 25 + 71

2.50 / 2.91

2.50 / 2.91

7.10 / 8.27

22 + 22 + 25 + 35

2.20 / 2.56

2.20 / 2.56

2.50 / 2.91

3.50 / 4.07

22 + 60 + 60 + 60

1.52 / 1.96

4.16 / 5.35

4.16 / 5.35

4.16 / 5.35

25 + 100

2.50 / 2.90 10.00 / 11.60

25 + 25 + 100

2.33 / 3.00

2.33 / 3.00

9.33 / 12.00

22 + 22 + 25 + 50

2.20 / 2.55

2.20 / 2.55

2.50 / 2.90

5.00 / 5.80

25 + 25 + 25 + 25

2.50 / 2.90

2.50 / 2.90

2.50 / 2.90

2.50 / 2.90

35 + 35

3.50 / 4.05

3.50 / 4.05

25 + 35 + 35

2.50 / 2.89

3.50 / 4.05

3.50 / 4.05

22 + 22 + 25 + 60

2.20 / 2.56

2.20 / 2.56

2.50 / 2.91

6.00 / 6.98

25 + 25 + 25 + 35

2.50 / 2.91

2.50 / 2.91

2.50 / 2.91

3.50 / 4.07

35 + 50

3.50 / 4.08

5.00 / 5.82

25 + 35 + 50

2.50 / 2.91

3.50 / 4.07

5.00 / 5.82

22 + 22 + 25 + 71

2.20 / 2.83

2.20 / 2.83

2.50 / 3.21

7.10 / 9.13

25 + 25 + 25 + 50

2.50 / 2.90

2.50 / 2.90

2.50 / 2.90

5.00 / 5.80

35 + 60

3.50 / 4.05

6.00 / 6.95

25 + 35 + 60

2.50 / 2.90

3.50 / 4.05

6.00 / 6.95

22 + 22 + 25 + 100 1.82 / 2.34

1.82 / 2.34

2.07 / 2.66

8.28 / 10.65

25 + 25 + 25 + 60

2.50 / 2.91

2.50 / 2.91

2.50 / 2.91

6.00 / 6.98

35 + 71

3.50 / 4.06

7.10 / 8.24

25 + 35 + 71

2.50 /2.90

3.50 / 4.06

7.10 / 8.24

22 + 22 + 35 + 35

2.20 / 2.55

2.20 / 2.55

3.50 / 4.05

3.50 / 4.05

25 + 25 + 25 + 71

2.40 / 3.08

2.40 / 3.08

2.40 / 3.08

6.81 / 8.75

2.20 / 2.56

2.20 / 2.56

3.50 / 4.07

5.00 / 5.81

25 + 25 + 25 + 100 2.00 / 2.57

35 + 100

3.50 / 4.07 10.00 / 11.63

25 + 35 + 100

2.19 / 2.81

3.06 / 3.94

8.75 / 11.25

22 + 22 + 35 + 50

2.00 / 2.57

2.00 / 2.57

8.00 / 10.29

50 + 50

5.00 / 5.80

5.00 / 5.80

25 + 50 + 50

2.50 / 2.90

5.00 / 5.80

5.00 / 5.80

22 + 22 + 35 + 60

2.20 / 2.55

2.20 / 2.55

3.50 / 4.05

6.00 / 6.95

25 + 25 + 35 + 35

2.50 / 2.90

2.50 / 2.90

3.50 / 4.05

3.50 / 4.05

50 + 60

5.00 / 5.82

6.00 / 6.98

25 + 50 + 60

2.50 / 2.91

5.00 / 5.81

6.00 / 6.98

22 + 22 + 35 + 71

2.05 / 2.64

2.05 / 2.64

3.27 / 4.20

6.63 / 8.52

25 + 25 + 35 + 50

2.50 / 2.91

2.50 / 2.91

3.50 / 4.07

5.00 / 5.81

50 + 71

5.00 / 5.83

7.10 / 8.27

25 + 50 + 71

2.40 / 3.08

4.79 / 6.16

6.81 / 8.75

22 + 22 + 35 + 100 1.72 / 2.21

1.72 / 2.21

2.74 / 3.52

7.82 / 10.06

25 + 25 + 35 + 60

2.41 / 3.10

2.41 / 3.10

3.38 / 4.34

5.79 / 7.45

2.14 / 2.75

2.14 / 2.75

4.86 / 6.25

4.86 / 6.25

25 + 25 + 35 + 71

50 + 100

4.67 / 6.00

9.33 / 12.00

25 + 50 + 100

2.00 / 2.57

4.00 / 5.14

8.00 / 10.29

22 + 22 + 50 + 50

2.24 / 2.88

2.24 / 2.88

3.14 / 4.04

6.37 / 8.19

60 + 60

6.00 / 6.95

6.00 / 6.95

25 + 60 + 60

2.41 / 3.10

5.79 / 7.45

5.79 / 7.45

22 + 22 + 50 + 60

2.00 / 2.57

2.00 / 2.57

4.55 / 5.84

5.45 / 7.01

25 + 25 + 35 + 100 1.89 / 2.43

1.89 / 2.43

2.65 / 3.41

7.57 / 9.73

60 + 71

6.00 / 6.96

7.10 / 8.24

25 + 60 + 71

2.24 / 2.88

5.38 / 6.92

6.37 / 8.19

22 + 22 + 50 + 71

1.87 / 2.40

1.87 / 2.40

4.24 / 5.45

6.02 / 7.75

25 + 25 + 50 + 50

2.33 / 3.00

2.33 / 3.00

4.67 / 6.00

4.67 / 6.00

60 + 100

5.25 / 6.75

8.75 / 11.25

25 + 60 + 100

1.89 / 2.43

4.54 / 5.84

7.57 / 9.73

22 + 22 + 50 + 100 1.59 / 2.04

1.59 / 2.04

3.61 / 4.64

7.22 / 9.28

25 + 25 + 50 + 60

2.19 / 2.81

2.19 / 2.81

4.38 / 5.63

5.25 / 6.75

25 + 71 + 71

2.10 / 2.69

5.95 / 7.65

5.95 / 7.65

22 + 22 + 60 + 60

1.88 / 2.41

1.88 / 2.41

5.12 / 6.59

5.12 / 6.59

25 + 25 + 50 + 71

2.05 / 2.63

2.05 / 2.63

4.09 / 5.26

5.81 / 7.47

25 + 71 + 100

1.79 / 2.30

5.07 / 6.52

7.14 / 9.18

22 + 22 + 60 + 71

1.76 / 2.26

1.76 / 2.26

4.80 / 6.17

5.68 / 7.30

25 + 25 + 50 + 100 1.75 / 2.25

1.75 / 2.25

3.50 / 4.50

7.00 / 9.00

35 + 35 + 35

3.50 / 4.07

3.50 / 4.07

3.50 / 4.07

22 + 22 + 71 + 71

1.66 / 2.13

1.66 / 2.13

5.34 / 6.87

5.34 / 6.87

25 + 25 + 60 + 60

2.06 / 2.65

2.06 / 2.65

4.94 / 6.35

4.94 / 6.35

35 + 35 + 50

3.50 / 4.05

3.50 / 4.05

5.00 / 5.79

22 + 25 + 25 + 25

2.20 / 2.56

2.50 / 2.91

2.50 / 2.91

2.50 / 2.91

25 + 25 + 60 + 71

1.93 / 2.49

1.93 / 2.49

4.64 / 5.97

5.49 / 7.06

2.20 / 2.55

2.50 / 2.90

2.50 / 2.90

3.50 / 4.06

25 + 25 + 71 + 71

71 + 71

7.00 / 9.00

7.00 / 9.00

71 + 100

5.81 / 7.47

8.19 / 10.53

100 + 100

7.00 / 9.00

7.00 / 9.00

3 ROOMS

3.50 / 4.07

3.50 / 4.07

6.00 / 6.97

22 + 25 + 25 + 35

1.82 / 2.34

1.82 / 2.34

5.18 / 6.66

5.18 / 6.66

22 + 22 + 22

2.20 / 2.57

2.20 / 2.57

2.20 / 2.57

35 + 35 + 71

3.48 / 4.47

3.48 / 4.47

7.05 / 9.06

22 + 25 + 25 + 50

2.20 / 2.56

2.50 / 2.91

2.50 / 2.91

5.00 / 5.82

25 + 35 + 35 + 35

2.50 / 2.90

3.50 / 4.07

3.50 / 4.07

3.50 / 4.07

22 + 22 + 25

2.20 / 2.55

2.20 / 2.55

2.50 / 2.90

35 + 35 + 100

2.88 / 3.71

2.88 / 3.71

8.24 / 10.59

22 + 25 + 25 + 60

2.20 / 2.55

2.50 / 2.90

2.50 / 2.90

6.00 / 6.95

25 + 35 + 35 + 50

2.41 / 3.10

3.38 / 4.34

3.38 / 4.34

4.83 / 6.21

22 + 22 + 35

2.20 / 2.56

2.20 / 2.56

3.50 / 4.08

35 + 50 + 50

3.50 / 4.07

5.00 / 5.81

5.00 / 5.81

22 + 25 + 25 + 71

2.15 / 2.77

2.45 / 3.15

2.45 / 3.15

6.95 / 8.94

25 + 35 + 35 + 60

2.26 / 2.90

3.16 / 4.06

3.16 / 4.06

5.42 / 6.97

2.03 / 2.62

2.03 / 2.62

8.14 / 10.47

25 + 35 + 35 + 71

35 + 35 + 60

22 + 22 + 50

2.20 / 2.55

2.20 / 2.55

5.00 / 5.80

35 + 50 + 60

3.38 / 4.34

4.83 / 6.21

5.79 / 7.45

22 + 25 + 25 + 100 1.79 / 2.30

2.11 / 2.71

2.95 / 3.80

2.95 / 3.80

5.99 / 7.70

22 + 22 + 60

2.20 / 2.56

2.20 / 2.56

6.00 / 6.98

35 + 50 + 71

3.14 / 4.04

4.49 / 5.77

6.37 / 8.19

22 + 25 + 35 + 35

2.20 / 2.56

2.50 / 2.91

3.50 / 4.07

3.50 / 4.07

25 + 35 + 35 + 100 1.79 / 2.31

2.51 / 3.23

2.51 / 3.23

7.18 / 9.23

22 + 22 + 71

2.20 / 2.56

2.20 / 2.56

7.10 / 8.27

35 + 50 + 100

2.65 / 3.41

3.78 / 4.86

7.57 / 9.73

22 + 25 + 35 + 50

2.20 / 2.55

2.50 / 2.90

3.50 / 4.06

5.00 / 5.80

25 + 35 + 50 + 50

2.19 / 2.81

3.06 / 3.94

4.38 / 5.63

4.38 / 5.63

22 + 22 + 100

2.14 / 2.75

2.14 / 2.75

9.72 / 12.50

35 + 60 + 60

3.16 / 4.06

5.42 / 6.97

5.42 / 6.97

22 + 25 + 35 + 60

2.17 / 2.79

2.46 / 3.17

3.45 / 4.44

5.92 / 7.61

25 + 35 + 50 + 60

2.06 / 2.65

2.88 / 3.71

4.12 / 5.29

4.94 / 6.35

Page 52

Page 53


Indoor unit combination

Indoor unit combination

Cooling / Heating Capacity (kW)

Cooling / Heating Capacity (kW)

Unit A

Unit B

Unit C

Unit D

Unit A

Unit B

Unit C

Unit D

Unit E

25 + 35 + 50 + 71

1.93 / 2.49

2.71 / 3.48

3.87 / 4.97

5.49 / 7.06

22 + 22 + 25 + 25 + 71

1.87 / 2.40

1.87 / 2.40

2.12 / 2.73

2.12 / 2.73

6.02 / 7.75

25 + 35 + 60 + 60

1.94 / 2.50

2.72 / 3.50

4.67 / 6.00

4.67 / 6.00

22 + 22 + 25 + 25 + 100

1.59 / 2.04

1.59 / 2.04

1.80 / 2.32

1.80 / 2.32

7.22 / 9.28

25 + 35 + 60 + 71

1.83 / 2.36

2.57 / 3.30

4.40 / 5.65

5.20 / 6.69

22 + 22 + 25 + 35 + 35

2.20 / 2.55

2.20 / 2.55

2.50 / 2.90

3.50 / 4.05

3.50 / 4.05

25 + 35 + 71 + 71

1.73 / 2.23

2.43 / 3.12

4.92 / 6.33

4.92 / 6.33

22 + 22 + 25 + 35 + 50

2.00 / 2.57

2.00 / 2.57

2.27 / 2.92

3.18 / 4.09

4.55 / 5.84

25 + 50 + 50 + 50

2.00 / 2.57

4.00 / 5.14

4.00 / 5.14

4.00 / 5.14

22 + 22 + 25 + 35 + 60

1.88 / 2.41

1.88 / 2.41

2.13 / 2.74

2.99 / 3.84

5.12 / 6.59

Unit E

Unit F

Unit G

Unit H

25 + 50 + 50 + 60

1.89 / 2.43

3.78 / 4.86

3.78 / 4.86

4.54 / 5.84

22 + 22 + 25 + 35 + 71

1.76 / 2.26

1.76 / 2.26

2.00 / 2.57

2.80 / 3.60

5.68 / 7.30

25 + 50 + 50 + 71

1.79 / 2.30

3.57 / 4.59

3.57 / 4.59

5.07 / 6.52

22 + 22 + 25 + 50 + 50

1.82 / 2.34

1.82 / 2.34

2.07 / 2.66

4.14 / 5.33

4.14 / 5.33

25 + 50 + 60 + 60

1.79 / 2.31

3.59 / 4.62

4.31 / 5.54

4.31 / 5.54

22 + 22 + 25 + 50 + 60

1.72 / 2.21

1.72 / 2.21

1.96 / 2.51

3.91 / 5.03

4.69 / 6.03

35 + 35 + 35 + 35

3.50 / 4.50

3.50 / 4.50

3.50 / 4.50

3.50 / 4.50

22 + 22 + 25 + 50 + 71

1.62 / 2.08

1.62 / 2.08

1.84 / 2.37

3.68 / 4.74

5.23 / 6.73

35 + 35 + 35 + 50

3.16 / 4.06

3.16 / 4.06

3.16 / 4.06

4.52 / 5.81

22 + 22 + 25 + 60 + 60

1.63 / 2.10

1.63 / 2.10

1.85 / 2.38

4.44 / 5.71

4.44 / 5.71

35 + 35 + 35 + 60

2.97 / 3.82

2.97 / 3.82

2.97 / 3.82

5.09 / 6.55

22 + 22 + 25 + 60 + 71

1.54 / 1.98

1.54 / 1.98

1.75 / 2.25

4.20 / 5.40

4.97 / 6.39

35 + 35 + 35 + 71

2.78 / 3.58

2.78 / 3.58

2.78 / 3.58

5.65 / 7.26

22 + 22 + 35 + 35 + 35

2.07 / 2.66

2.07 / 2.66

3.29 / 4.23

3.29 / 4.23

3.29 / 4.23

35 + 35 + 50 + 50

2.88 / 3.71

2.88 / 3.71

4.12 / 5.29

4.12 / 5.29

22 + 22 + 35 + 35 + 50

1.88 / 2.41

1.88 / 2.41

2.99 / 3.84

2.99 / 3.84

4.27 / 5.49

35 + 35 + 50 + 60

2.72 / 3.50

2.72 / 3.50

3.89 / 5.00

4.67 / 6.00

22 + 22 + 35 + 35 + 60

1.77 / 2.28

1.77 / 2.28

2.82 / 3.62

2.82 / 3.62

4.83 / 6.21

35 + 35 + 50 + 71

2.57 / 3.30

2.57 / 3.30

3.66 / 4.71

5.20 / 6.69

22 + 22 + 35 + 35 + 71

1.66 / 2.14

1.66 / 2.14

2.65 / 3.41

2.65 / 3.41

5.37 / 6.91

35 + 35 + 60 + 60

2.58 / 3.32

2.58 / 3.32

4.42 / 5.68

4.42 / 5.68

22 + 22 + 35 + 50 + 50

1.72 / 2.21

1.72 / 2.21

2.74 / 3.52

3.91 / 5.03

3.91 / 5.03

35 + 35 + 60 + 71

2.44 / 3.13

2.44 / 3.13

4.18 / 5.37

4.95 / 6.36

22 + 22 + 35 + 50 + 60

1.63 / 2.10

1.63 / 2.10

2.59 / 3.33

3.70 / 4.76

4.44 / 5.71

35 + 50 + 50 + 50

2.65 / 3.41

3.78 / 4.86

3.78 / 4.86

3.78 / 4.86

22 + 22 + 35 + 50 + 71

1.54 / 1.98

1.54 / 1.98

2.45 / 3.15

3.50 / 4.50

4.97 / 6.39

35 + 50 + 50 + 60

2.51 / 3.23

3.59 / 4.62

3.59 / 4.62

4.31 / 5.54

22 + 22 + 35 + 60 + 60

1.55 / 1.99

1.55 / 1.99

2.46 / 3.17

4.22 / 5.43

4.22 / 5.43

50 + 50 + 50 + 50

3.50 / 4.50

3.50 / 4.50

3.50 / 4.50

3.50 / 4.50

22 + 22 + 50 + 50 + 50

1.59 / 2.04

1.59 / 2.04

3.61 / 4.64

3.61 / 4.64

3.61 / 4.64

22 + 25 + 25 + 25 + 25

2.20 / 2.56

2.50 / 2.91

2.50 / 2.91

2.50 / 2.91

2.50 / 2.91

22 + 25 + 25 + 25 + 35

2.20 / 2.55

2.50 / 2.90

2.50 / 2.90

2.50 / 2.90

3.50 / 4.06

2.20 / 2.56

22 + 25 + 25 + 25 + 50

2.10 / 2.69

2.38 / 3.06

2.38 / 3.06

2.38 / 3.06

4.76 / 6.12

2.50 / 2.90

22 + 25 + 25 + 25 + 60

1.96 / 2.52

2.23 / 2.87

2.23 / 2.87

2.23 / 2.87

5.35 / 6.88

5 ROOMS 22 + 22 + 22 + 22 + 22 22 + 22 + 22 + 22 + 25

2.20 / 2.56 2.20 / 2.55

2.20 / 2.56 2.20 / 2.55

2.20 / 2.56 2.20 / 2.55

2.20 / 2.56 2.20 / 2.55

22 + 22 + 22 + 22 + 35

2.20 / 2.56

2.20 / 2.56

2.20 / 2.56

2.20 / 2.56

3.50 / 4.07

22 + 25 + 25 + 25 + 71

1.83 / 2.36

2.08 / 2.68

2.08 / 2.68

2.08 / 2.68

5.92 / 7.61

22 + 22 + 22 + 22 + 50

2.20 / 2.55

2.20 / 2.55

2.20 / 2.55

2.20 / 2.55

5.00 / 5.80

22 + 25 + 25 + 25 + 100

1.56 / 2.01

1.78 / 2.28

1.78 / 2.28

1.78 / 2.28

7.11 / 9.14

22 + 22 + 22 + 22 + 60

2.08 / 2.68

2.08 / 2.68

2.08 / 2.68

2.08 / 2.68

5.68 / 7.30

22 + 25 + 25 + 35 + 35

2.17 / 2.79

2.46 / 3.17

2.46 / 3.17

3.45 / 4.44

3.45 / 4.44

1.96 / 2.52

2.23 / 2.87

2.23 / 2.87

3.12 / 4.01

4.46 / 5.73

22 + 22 + 22 + 22 + 71

1.94 / 2.49

1.94 / 2.49

1.94 / 2.49

1.94 / 2.49

6.25 / 8.04

22 + 25 + 25 + 35 + 50

22 + 22 + 22 + 22 + 100

1.64 / 2.11

1.64 / 2.11

1.64 / 2.11

1.64 / 2.11

7.45 / 9.57

22 + 25 + 25 + 35 + 60

1.84 / 2.37

2.10 / 2.69

2.10 / 2.69

2.93 / 3.77

5.03 / 6.47

22 + 22 + 22 + 25 + 25

2.20 / 2.56

2.20 / 2.56

2.20 / 2.56

2.50 / 2.91

2.50 / 2.91

22 + 25 + 25 + 35 + 71

1.73 / 2.22

1.97 / 2.53

1.97 / 2.53

2.75 / 3.54

5.58 / 7.18

22 + 22 + 22 + 25 + 35

2.20 / 2.55

2.20 / 2.55

2.20 / 2.55

2.50 / 2.90

3.50 / 4.06

22 + 25 + 25 + 50 + 50

1.79 / 2.30

2.03 / 2.62

2.03 / 2.62

4.07 / 5.23

4.07 / 5.23

1.69 / 2.18

1.92 / 2.47

1.92 / 2.47

3.85 / 4.95

4.62 / 5.93

22 + 22 + 22 + 25 + 50

2.18 / 2.81

2.18 / 2.81

2.18 / 2.81

2.48 / 3.19

4.96 / 6.38

22 + 25 + 25 + 50 + 60

22 + 22 + 22 + 25 + 60

2.04 / 2.62

2.04 / 2.62

2.04 / 2.62

2.32 / 2.98

5.56 / 7.15

22 + 25 + 25 + 50 + 71

1.60 / 2.05

1.81 / 2.33

1.81 / 2.33

3.63 / 4.66

5.15 / 6.62

22 + 22 + 22 + 25 + 71

1.90 / 2.44

1.90 / 2.44

1.90 / 2.44

2.16 / 2.78

6.14 / 7.89

22 + 25 + 25 + 60 + 60

1.60 / 2.06

1.82 / 2.34

1.82 / 2.34

4.38 / 5.63

4.38 / 5.63

22 + 22 + 22 + 25 + 100

1.61 / 2.07

1.61 / 2.07

1.61 / 2.07

1.83 / 2.36

7.33 / 9.42

22 + 25 + 35 + 35 + 35

2.03 / 2.61

2.30 / 2.96

3.22 / 4.14

3.22 / 4.14

3.22 / 4.14

22 + 22 + 22 + 35 + 35

2.20 / 2.56

2.20 / 2.56

2.20 / 2.56

3.50 / 4.07

3.50 / 4.07

22 + 25 + 35 + 35 + 50

1.84 / 2.37

2.10 / 2.69

2.93 / 3.77

2.93 / 3.77

4.19 / 5.39

22 + 22 + 22 + 35 + 50

2.04 / 2.62

2.04 / 2.62

2.04 / 2.62

3.25 / 4.17

4.64 / 5.96

22 + 25 + 35 + 35 + 60

1.74 / 2.24

1.98 / 2.54

2.77 / 3.56

2.77 / 3.56

4.75 / 6.10

22 + 22 + 22 + 35 + 60

1.91 / 2.46

1.91 / 2.46

1.91 / 2.46

3.04 / 3.91

5.22 / 6.71

22 + 25 + 35 + 35 + 71

1.64 / 2.11

1.86 / 2.39

2.61 / 3.35

2.61 / 3.35

5.29 / 6.80

22 + 22 + 22 + 35 + 71

1.79 / 2.30

1.79 / 2.30

1.79 / 2.30

2.85 / 3.66

5.78 / 7.43

22 + 25 + 35 + 50 + 50

1.69 / 2.18

1.92 / 2.47

2.69 / 3.46

3.85 / 4.95

3.85 / 4.95

22 + 22 + 22 + 35 + 100

1.53 / 1.97

1.53 / 1.97

1.53 / 1.97

2.44 / 3.13

6.97 / 8.96

22 + 25 + 35 + 50 + 60

1.60 / 2.06

1.82 / 2.34

2.55 / 3.28

3.65 / 4.69

4.38 / 5.63

22 + 22 + 22 + 50 + 50

1.86 / 2.39

1.86 / 2.39

1.86 / 2.39

4.22 / 5.42

4.22 / 5.42

22 + 25 + 35 + 60 + 60

1.52 / 1.96

1.73 / 2.23

2.43 / 3.12

4.16 / 5.35

4.16 / 5.35

22 + 22 + 22 + 50 + 60

1.75 / 2.25

1.75 / 2.25

1.75 / 2.25

3.98 / 5.11

4.77 / 6.14

22 + 25 + 50 + 50 + 50

1.56 / 2.01

1.78 / 2.28

3.55 / 4.57

3.55 / 4.57

3.55 / 4.57

22 + 22 + 22 + 50 + 71

1.65 / 2.12

1.65 / 2.12

1.65 / 2.12

3.74 / 4.81

5.32 / 6.83

22 + 35 + 35 + 35 + 35

1.90 / 2.44

3.02 / 3.89

3.02 / 3.89

3.02 / 3.89

3.02 / 3.89

22 + 22 + 22 + 60 + 60

1.66 / 2.13

1.66 / 2.13

1.66 / 2.13

4.52 / 5.81

4.52 / 5.81

22 + 35 + 35 + 35 + 50

1.74 / 2.24

2.77 / 3.56

2.77 / 3.56

2.77 / 3.56

3.95 / 5.08

22 + 22 + 22 + 60 + 71

1.56 / 2.01

1.56 / 2.01

1.56 / 2.01

4.26 / 5.48

5.05 / 6.49

22 + 35 + 35 + 35 + 60

1.65 / 2.12

2.62 / 3.37

2.62 / 3.37

2.62 / 3.37

4.49 / 5.78

22 + 22 + 25 + 25 + 25

2.20 / 2.55

2.20 / 2.55

2.50 / 2.90

2.50 / 2.90

2.50 / 2.90

22 + 35 + 35 + 35 + 71

1.56 / 2.00

2.47 / 3.18

2.47 / 3.18

2.47 / 3.18

5.02 / 6.45

22 + 22 + 25 + 25 + 35

2.20 / 2.56

2.20 / 2.56

2.50 / 2.91

2.50 / 2.91

3.50 / 4.07

22 + 35 + 35 + 50 + 50

1.60 / 2.06

2.55 / 3.28

2.55 / 3.28

3.65 / 4.69

3.65 / 4.69

1.52 / 1.96

2.43 / 3.12

2.43 / 3.12

3.47 / 4.46

4.16 / 5.35

2.50 / 2.90

2.50 / 2.90

2.50 / 2.90

2.50 / 2.90

2.50 / 2.90

22 + 22 + 25 + 25 + 50

2.14 / 2.75

2.14 / 2.75

2.43 / 3.13

2.43 / 3.13

4.86 / 6.25

22 + 35 + 35 + 50 + 60

22 + 22 + 25 + 25 + 60

2.00 / 2.57

2.00 / 2.57

2.27 / 2.92

2.27 / 2.92

5.45 / 7.01

25 + 25 + 25 + 25 + 25

Page 54

Unit F

Unit G

Unit H

Page 55


Indoor unit combination

Indoor unit combination

Cooling / Heating Capacity (kW) Unit F

Unit G

Unit H

Cooling / Heating Capacity (kW)

Unit A

Unit B

Unit C

Unit D

Unit E

Unit A

Unit B

Unit C

Unit D

Unit E

Unit F

25 + 25 + 25 + 25 + 35

2.50 / 2.91

2.50 / 2.91

2.50 / 2.91

2.50 / 2.91

3.50 / 4.07

22 + 22 + 22 + 25 + 25 + 50

1.86 / 2.39

1.86 / 2.39

1.86 / 2.39

2.11 / 2.71

2.11 / 2.71

4.22 / 5.42

25 + 25 + 25 + 25 + 50

2.33 / 3.00

2.33 / 3.00

2.33 / 3.00

2.33 / 3.00

4.67 / 6.00

22 + 22 + 22 + 25 + 25 + 60

1.75 / 2.25

1.75 / 2.25

1.75 / 2.25

1.99 / 2.56

1.99 / 2.56

4.77 / 6.14

25 + 25 + 25 + 25 + 60

2.19 / 2.81

2.19 / 2.81

2.19 / 2.81

2.19 / 2.81

5.25 / 6.75

22 + 22 + 22 + 25 + 25 + 71

1.65 / 2.12

1.65 / 2.12

1.65 / 2.12

1.87 / 2.41

1.87 / 2.41

5.32 / 6.83

25 + 25 + 25 + 25 + 71

2.05 / 2.63

2.05 / 2.63

2.05 / 2.63

2.05 / 2.63

5.81 / 7.47

22 + 22 + 22 + 25 + 35 + 35

1.91 / 2.46

1.91 / 2.46

1.91 / 2.46

2.17 / 2.80

3.04 / 3.91

3.04 / 3.91

25 + 25 + 25 + 25 + 100

1.75 / 2.25

1.75 / 2.25

1.75 / 2.25

1.75 / 2.25

7.00 / 9.00

22 + 22 + 22 + 25 + 35 + 50

1.75 / 2.25

1.75 / 2.25

1.75 / 2.25

1.99 / 2.56

2.78 / 3.58

3.98 / 5.11

25 + 25 + 25 + 35 + 35

2.41 / 3.10

2.41 / 3.10

2.41 / 3.10

3.38 / 4.34

3.38 / 4.34

22 + 22 + 22 + 25 + 35 + 60

1.66 / 2.13

1.66 / 2.13

1.66 / 2.13

1.88 / 2.42

2.63 / 3.39

4.52 / 5.81

25 + 25 + 25 + 35 + 50

2.19 / 2.81

2.19 / 2.81

2.19 / 2.81

3.06 / 3.94

4.38 / 5.63

22 + 22 + 22 + 25 + 35 + 71

1.56 / 2.01

1.56 / 2.01

1.56 / 2.01

1.78 / 2.28

2.49 / 3.20

5.05 / 6.49

25 + 25 + 25 + 35 + 60

2.06 / 2.65

2.06 / 2.65

2.06 / 2.65

2.88 / 3.71

4.94 / 6.35

22 + 22 + 22 + 25 + 50 + 50

1.61 / 2.07

1.61 / 2.07

1.61 / 2.07

1.83 / 2.36

3.66 / 4.71

3.66 / 4.71

25 + 25 + 25 + 35 + 71

1.93 / 2.49

1.93 / 2.49

1.93 / 2.49

2.71 / 3.48

5.49 / 7.06

22 + 22 + 22 + 25 + 50 + 60

1.53 / 1.97

1.53 / 1.97

1.53 / 1.97

1.74 / 2.24

3.48 / 4.48

4.18 / 5.37

25 + 25 + 25 + 50 + 50

2.00 / 2.57

2.00 / 2.57

2.00 / 2.57

4.00 / 5.14

4.00 / 5.14

22 + 22 + 22 + 35 + 35 + 35

1.80 / 2.32

1.80 / 2.32

1.80 / 2.32

2.87 / 3.68

2.87 / 3.68

2.87 / 3.68

25 + 25 + 25 + 50 + 60

1.89 / 2.43

1.89 / 2.43

1.89 / 2.43

3.78 / 4.86

4.54 / 5.84

22 + 22 + 22 + 35 + 35 + 50

1.66 / 2.13

1.66 / 2.13

1.66 / 2.13

2.63 / 3.39

2.63 / 3.39

3.76 / 4.84

25 + 25 + 25 + 50 + 71

1.79 / 2.30

1.79 / 2.30

1.79 / 2.30

3.57 / 4.59

5.07 / 6.52

22 + 22 + 22 + 35 + 35 + 60

1.57 / 2.02

1.57 / 2.02

1.57 / 2.02

2.50 / 3.21

2.50 / 3.21

4.29 / 5.51

25 + 25 + 25 + 60 + 60

1.79 / 2.31

1.79 / 2.31

1.79 / 2.31

4.31 / 5.54

4.31 / 5.54

22 + 22 + 22 + 35 + 50 + 50

1.53 / 1.97

1.53 / 1.97

1.53 / 1.97

2.44 / 3.13

3.48 / 4.48

3.48 / 4.48

25 + 25 + 35 + 35 + 35

2.26 / 2.90

2.26 / 2.90

3.16 / 4.06

3.16 / 4.06

3.16 / 4.06

22 + 22 + 25 + 25 + 25 + 25

2.14 / 2.75

2.14 / 2.75

2.43 / 3.13

2.43 / 3.13

2.43 / 3.13

2.43 / 3.13

25 + 25 + 35 + 35 + 50

2.06 / 2.65

2.06 / 2.65

2.88 / 3.71

2.88 / 3.71

4.12 / 5.29

22 + 22 + 25 + 25 + 25 + 35

2.00 / 2.57

2.00 / 2.57

2.27 / 2.92

2.27 / 2.92

2.27 / 2.92

3.18 / 4.09

25 + 25 + 35 + 35 + 60

1.94 / 2.50

1.94 / 2.50

2.72 / 3.50

2.72 / 3.50

4.67 / 6.00

22 + 22 + 25 + 25 + 25 + 50

1.82 / 2.34

1.82 / 2.34

2.07 / 2.66

2.07 / 2.66

2.07 / 2.66

4.14 / 5.33

25 + 25 + 35 + 35 + 71

1.83 / 2.36

1.83 / 2.36

2.57 / 3.30

2.57 / 3.30

5.20 / 6.69

22 + 22 + 25 + 25 + 25 + 60

1.72 / 2.21

1.72 / 2.21

1.96 / 2.51

1.96 / 2.51

1.96 / 2.51

4.69 / 6.03

25 + 25 + 35 + 50 + 50

1.89 / 2.43

1.89 / 2.43

2.65 / 3.41

3.78 / 4.86

3.78 / 4.86

22 + 22 + 25 + 25 + 25 + 71

1.62 / 2.08

1.62 / 2.08

1.84 / 2.37

1.84 / 2.37

1.84 / 2.37

5.23 / 6.73

25 + 25 + 35 + 50 + 60

1.79 / 2.31

1.79 / 2.31

2.51 / 3.23

3.59 / 4.62

4.31 / 5.54

22 + 22 + 25 + 25 + 35 + 35

1.88 / 2.41

1.88 / 2.41

2.13 / 2.74

2.13 / 2.74

2.99 / 3.84

2.99 / 3.84

25 + 25 + 50 + 50 + 50

1.75 / 2.25

1.75 / 2.25

3.50 / 4.50

3.50 / 4.50

3.50 / 4.50

22 + 22 + 25 + 25 + 35 + 50

1.72 / 2.21

1.72 / 2.21

1.96 / 2.51

1.96 / 2.51

2.74 / 3.52

3.91 / 5.03

25 + 35 + 35 + 35 + 35

2.12 / 2.73

2.97 / 3.82

2.97 / 3.82

2.97 / 3.82

2.97 / 3.82

22 + 22 + 25 + 25 + 35 + 60

1.63 / 2.10

1.63 / 2.10

1.85 / 2.38

1.85 / 2.38

2.59 / 3.33

4.44 / 5.71

25 + 35 + 35 + 35 + 50

1.94 / 2.50

2.72 / 3.50

2.72 / 3.50

2.72 / 3.50

3.89 / 5.00

22 + 22 + 25 + 25 + 35 + 71

1.54 / 1.98

1.54 / 1.98

1.75 / 2.25

1.75 / 2.25

2.45 / 3.15

4.97 / 6.39

25 + 35 + 35 + 35 + 60

1.84 / 2.37

2.58 / 3.32

2.58 / 3.32

2.58 / 3.32

4.42 / 5.68

22 + 22 + 25 + 25 + 50 + 50

1.59 / 2.04

1.59 / 2.04

1.80 / 2.32

1.80 / 2.32

3.61 / 4.64

3.61 / 4.64

25 + 35 + 35 + 35 + 71

1.74 / 2.24

2.44 / 3.13

2.44 / 3.13

2.44 / 3.13

4.95 / 6.36

22 + 22 + 25 + 35 + 35 + 35

1.77 / 2.28

1.77 / 2.28

2.01 / 2.59

2.82 / 3.62

2.82 / 3.62

2.82 / 3.62

25 + 35 + 35 + 50 + 50

1.79 / 2.31

2.51 / 3.23

2.51 / 3.23

3.59 / 4.62

3.59 / 4.62

22 + 22 + 25 + 35 + 35 + 50

1.63 / 2.10

1.63 / 2.10

1.85 / 2.38

2.59 / 3.33

2.59 / 3.33

3.70 / 4.76

35 + 35 + 35 + 35 + 35

2.80 / 3.60

2.80 / 3.60

2.80 / 3.60

2.80 / 3.60

2.80 / 3.60

22 + 22 + 25 + 35 + 35 + 60

1.55 / 1.99

1.55 / 1.99

1.76 / 2.26

2.46 / 3.17

2.46 / 3.17

4.22 / 5.43

35 + 35 + 35 + 35 + 50

2.58 / 3.32

2.58 / 3.32

2.58 / 3.32

2.58 / 3.32

3.68 / 4.74

22 + 22 + 35 + 35 + 35 + 35

1.67 / 2.15

1.67 / 2.15

2.66 / 3.42

2.66 / 3.42

2.66 / 3.42

2.66 / 3.42

35 + 35 + 35 + 35 + 60

2.45 / 3.15

2.45 / 3.15

2.45 / 3.15

2.45 / 3.15

4.20 / 5.40

22 + 22 + 35 + 35 + 35 + 50

1.55 / 1.99

1.55 / 1.99

2.46 / 3.17

2.46 / 3.17

2.46 / 3.17

3.52 / 4.52

22 + 25 + 25 + 25 + 25 + 25

2.10 / 2.69

2.38 / 3.06

2.38 / 3.06

2.38 / 3.06

2.38 / 3.06

2.38 / 3.06

22 + 25 + 25 + 25 + 25 + 35

1.96 / 2.52

2.23 / 2.87

2.23 / 2.87

2.23 / 2.87

2.23 / 2.87

3.12 / 4.01

22 + 25 + 25 + 25 + 25 + 50

6 ROOMS

1.79 / 2.30

2.03 / 2.62

2.03 / 2.62

2.03 / 2.62

2.03 / 2.62

4.07 / 5.23

22 + 22 + 22 + 22 + 22 + 22

2.20 / 2.55

2.20 / 2.55

2.20 / 2.55

2.20 / 2.55

2.20 / 2.55

2.20 / 2.55

22 + 25 + 25 + 25 + 25 + 60

1.69 / 2.18

1.92 / 2.47

1.92 / 2.47

1.92 / 2.47

1.92 / 2.47

4.62 / 5.93

22 + 22 + 22 + 22 + 22 + 25

2.20 / 2.56

2.20 / 2.56

2.20 / 2.56

2.20 / 2.56

2.20 / 2.56

2.50 / 2.91

22 + 25 + 25 + 25 + 25 + 71

1.60 / 2.05

1.81 / 2.33

1.81 / 2.33

1.81 / 2.33

1.81 / 2.33

5.15 / 6.62

22 + 22 + 22 + 22 + 22 + 35

2.12 / 2.73

2.12 / 2.73

2.12 / 2.73

2.12 / 2.73

2.12 / 2.73

3.38 / 4.34

22 + 25 + 25 + 25 + 35 + 35

1.84 / 2.37

2.10 / 2.69

2.10 / 2.69

2.10 / 2.69

2.93 / 3.77

2.93 / 3.77

22 + 22 + 22 + 22 + 22 + 50

1.93 / 2.48

1.93 / 2.48

1.93 / 2.48

1.93 / 2.48

1.93 / 2.48

4.38 / 5.63

22 + 25 + 25 + 25 + 35 + 50

1.69 / 2.18

1.92 / 2.47

1.92 / 2.47

1.92 / 2.47

2.69 / 3.46

3.85 / 4.95

22 + 22 + 22 + 22 + 22 + 60

1.81 / 2.33

1.81 / 2.33

1.81 / 2.33

1.81 / 2.33

1.81 / 2.33

4.94 / 6.35

22 + 25 + 25 + 25 + 35 + 60

1.60 / 2.06

1.82 / 2.34

1.82 / 2.34

1.82 / 2.34

2.55 / 3.28

4.38 / 5.63

22 + 22 + 22 + 22 + 22 + 71

1.70 / 2.19

1.70 / 2.19

1.70 / 2.19

1.70 / 2.19

1.70 / 2.19

5.49 / 7.06

22 + 25 + 25 + 25 + 50 + 50

1.56 / 2.01

1.78 / 2.28

1.78 / 2.28

1.78 / 2.28

3.55 / 4.57

3.55 / 4.57

22 + 22 + 22 + 22 + 25 + 25

2.20 / 2.55

2.20 / 2.55

2.20 / 2.55

2.20 / 2.55

2.50 / 2.90

2.50 / 2.90

22 + 25 + 25 + 35 + 35 + 35

1.74 / 2.24

1.98 / 2.54

1.98 / 2.54

2.77 / 3.56

2.77 / 3.56

2.77 / 3.56

22 + 22 + 22 + 22 + 25 + 35

2.08 / 2.68

2.08 / 2.68

2.08 / 2.68

2.08 / 2.68

2.36 / 3.04

3.31 / 4.26

22 + 25 + 25 + 35 + 35 + 50

1.60 / 2.06

1.82 / 2.34

1.82 / 2.34

2.55 / 3.28

2.55 / 3.28

3.65 / 4.69

22 + 22 + 22 + 22 + 25 + 50

1.89 / 2.43

1.89 / 2.43

1.89 / 2.43

1.89 / 2.43

2.15 / 2.76

4.29 / 5.52

22 + 25 + 25 + 35 + 35 + 60

1.52 / 1.96

1.73 / 2.23

1.73 / 2.23

2.43 / 3.12

2.43 / 3.12

4.16 / 5.35

22 + 22 + 22 + 22 + 25 + 60

1.78 / 2.29

1.78 / 2.29

1.78 / 2.29

1.78 / 2.29

2.02 / 2.60

4.86 / 6.24

22 + 25 + 35 + 35 + 35 + 35

1.65 / 2.12

1.87 / 2.41

2.62 / 3.37

2.62 / 3.37

2.62 / 3.37

2.62 / 3.37

22 + 22 + 22 + 22 + 25 + 71

1.67 / 2.15

1.67 / 2.15

1.67 / 2.15

1.67 / 2.15

1.90 / 2.45

5.40 / 6.95

22 + 25 + 35 + 35 + 35 + 50

1.52 / 1.96

1.73 / 2.23

2.43 / 3.12

2.43 / 3.12

2.43 / 3.12

3.47 / 4.46

22 + 22 + 22 + 22 + 35 + 35

1.95 / 2.51

1.95 / 2.51

1.95 / 2.51

1.95 / 2.51

3.10 / 3.99

3.10 / 3.99

22 + 35 + 35 + 35 + 35 + 35

1.56 / 2.01

2.49 / 3.20

2.49 / 3.20

2.49 / 3.20

2.49 / 3.20

2.49 / 3.20

22 + 22 + 22 + 22 + 35 + 50

1.78 / 2.29

1.78 / 2.29

1.78 / 2.29

1.78 / 2.29

2.83 / 3.64

4.05 / 5.20

25 + 25 + 25 + 25 + 25 + 25

2.33 / 3.00

2.33 / 3.00

2.33 / 3.00

2.33 / 3.00

2.33 / 3.00

2.33 / 3.00

22 + 22 + 22 + 22 + 35 + 60

1.68 / 2.16

1.68 / 2.16

1.68 / 2.16

1.68 / 2.16

2.68 / 3.44

4.59 / 5.90

25 + 25 + 25 + 25 + 25 + 35

2.19 / 2.81

2.19 / 2.81

2.19 / 2.81

2.19 / 2.81

2.19 / 2.81

3.06 / 3.94

22 + 22 + 22 + 22 + 35 + 71

1.59 / 2.04

1.59 / 2.04

1.59 / 2.04

1.59 / 2.04

2.53 / 3.25

5.12 / 6.59

25 + 25 + 25 + 25 + 25 + 50

2.00 / 2.57

2.00 / 2.57

2.00 / 2.57

2.00 / 2.57

2.00 / 2.57

4.00 / 5.14

22 + 22 + 22 + 22 + 50 + 50

1.64 / 2.11

1.64 / 2.11

1.64 / 2.11

1.64 / 2.11

3.72 / 4.79

3.72 / 4.79

25 + 25 + 25 + 25 + 25 + 60

1.89 / 2.43

1.89 / 2.43

1.89 / 2.43

1.89 / 2.43

1.89 / 2.43

4.54 / 5.84

22 + 22 + 22 + 22 + 50 + 60

1.56 / 2.00

1.56 / 2.00

1.56 / 2.00

1.56 / 2.00

3.54 / 4.55

4.24 / 5.45

25 + 25 + 25 + 25 + 25 + 71

1.79 / 2.30

1.79 / 2.30

1.79 / 2.30

1.79 / 2.30

1.79 / 2.30

5.07 / 6.52

22 + 22 + 22 + 25 + 25 + 25

2.18 / 2.81

2.18 / 2.81

2.18 / 2.81

2.48 / 3.19

2.48 / 3.19

2.48 / 3.19

25 + 25 + 25 + 25 + 35 + 35

2.06 / 2.65

2.06 / 2.65

2.06 / 2.65

2.06 / 2.65

2.88 / 3.71

2.88 / 3.71

22 + 22 + 22 + 25 + 25 + 35

2.04 / 2.62

2.04 / 2.62

2.04 / 2.62

2.32 / 2.98

2.32 / 2.98

3.25 / 4.17

25 + 25 + 25 + 25 + 35 + 50

1.89 / 2.43

1.89 / 2.43

1.89 / 2.43

1.89 / 2.43

2.65 / 3.41

3.78 / 4.86

Page 56

Unit G

Unit H

Page 57


Indoor unit combination

Indoor unit combination

Cooling / Heating Capacity (kW) Unit A

Unit B

Unit C

Unit D

Unit E

Unit F

25 + 25 + 25 + 25 + 35 + 60

1.79 / 2.31

1.79 / 2.31

1.79 / 2.31

1.79 / 2.31

2.51 / 3.23

4.31 / 5.54

25 + 25 + 25 + 25 + 50 + 50

1.75 / 2.25

1.75 / 2.25

1.75 / 2.25

1.75 / 2.25

3.50 / 4.50

3.50 / 4.50

25 + 25 + 25 + 35 + 35 + 35

1.94 / 2.50

1.94 / 2.50

1.94 / 2.50

2.72 / 3.50

2.72 / 3.50

2.72 / 3.50

25 + 25 + 25 + 35 + 35 + 50

1.79 / 2.31

1.79 / 2.31

1.79 / 2.31

2.51 / 3.23

2.51 / 3.23

25 + 25 + 35 + 35 + 35 + 35

1.84 / 2.37

1.84 / 2.37

2.58 / 3.32

2.58 / 3.32

25 + 35 + 35 + 35 + 35 + 35

1.75 / 2.25

2.45 / 3.15

2.45 / 3.15

2.45 / 3.15

Unit G

Unit H

Cooling / Heating Capacity (kW) Unit A

Unit B

Unit C

Unit D

Unit E

Unit F

Unit G

Unit H

22 + 22 + 22 + 22 + 22 + 22 + 22 + 22

1.75 / 2.25

1.75 / 2.25

1.75 / 2.25

1.75 / 2.25

1.75 / 2.25

1.75 / 2.25

1.75 / 2.25

1.75 / 2.25

3.59 / 4.62

22 + 22 + 22 + 22 + 22 + 22 + 22 + 25

1.72 / 2.21

1.72 / 2.21

1.72 / 2.21

1.72 / 2.21

1.72 / 2.21

1.72 / 2.21

1.72 / 2.21

1.96 / 2.51

2.58 / 3.32

2.58 / 3.32

22 + 22 + 22 + 22 + 22 + 22 + 22 + 35

1.63 / 2.10

1.63 / 2.10

1.63 / 2.10

1.63 / 2.10

1.63 / 2.10

1.63 / 2.10

1.63 / 2.10

2.59 / 3.33

2.45 / 3.15

2.45 / 3.15

22 + 22 + 22 + 22 + 22 + 22 + 25 + 25

1.69 / 2.18

1.69 / 2.18

1.69 / 2.18

1.69 / 2.18

1.69 / 2.18

1.69 / 2.18

1.92 / 2.47

1.92 / 2.47

22 + 22 + 22 + 22 + 22 + 22 + 25 + 35

1.60 / 2.06

1.60 / 2.06

1.60 / 2.06

1.60 / 2.06

1.60 / 2.06

1.60 / 2.06

1.82 / 2.34

2.55 / 3.28

22 + 22 + 22 + 22 + 22 + 22 + 35 + 35

1.52 / 1.96

1.52 / 1.96

1.52 / 1.96

1.52 / 1.96

1.52 / 1.96

1.52 / 1.96

2.43 / 3.12

2.43 / 3.12

22 + 22 + 22 + 22 + 22 + 25 + 25 + 25

1.66 / 2.14

1.66 / 2.14

1.66 / 2.14

1.66 / 2.14

1.66 / 2.14

1.89 / 2.43

1.89 / 2.43

1.89 / 2.43

22 + 22 + 22 + 22 + 22 + 25 + 25 + 35

1.58 / 2.03

1.58 / 2.03

1.58 / 2.03

1.58 / 2.03

1.58 / 2.03

1.79 / 2.31

1.79 / 2.31

2.51 / 3.23

8 ROOMS

7 ROOMS 22 + 22 + 22 + 22 + 22 + 22 + 22

2.00 / 2.57

2.00 / 2.57

2.00 / 2.57

2.00 / 2.57

2.00 / 2.57

2.00 / 2.57

2.00 / 2.57

22 + 22 + 22 + 22 + 25 + 25 + 25 + 25

1.64 / 2.11

1.64 / 2.11

1.64 / 2.11

1.64 / 2.11

1.86 / 2.39

1.86 / 2.39

1.86 / 2.39

1.86 / 2.39

22 + 22 + 22 + 22 + 22 + 22 + 25

1.96 / 2.52

1.96 / 2.52

1.96 / 2.52

1.96 / 2.52

1.96 / 2.52

1.96 / 2.52

2.23 / 2.87

22 + 22 + 22 + 22 + 25 + 25 + 25 + 35

1.56 / 2.00

1.56 / 2.00

1.56 / 2.00

1.56 / 2.00

1.77 / 2.27

1.77 / 2.27

1.77 / 2.27

2.47 / 3.18

22 + 22 + 22 + 22 + 22 + 22 + 35

1.84 / 2.37

1.84 / 2.37

1.84 / 2.37

1.84 / 2.37

1.84 / 2.37

1.84 / 2.37

2.93 / 3.77

22 + 22 + 22 + 25 + 25 + 25 + 25 + 25

1.61 / 2.07

1.61 / 2.07

1.61 / 2.07

1.83 / 2.36

1.83 / 2.36

1.83 / 2.36

1.83 / 2.36

1.83 / 2.36

22 + 22 + 22 + 22 + 22 + 22 + 50

1.69 / 2.18

1.69 / 2.18

1.69 / 2.18

1.69 / 2.18

1.69 / 2.18

1.69 / 2.18

3.85 / 4.95

22 + 22 + 22 + 25 + 25 + 25 + 25 + 35

1.53 / 1.97

1.53 / 1.97

1.53 / 1.97

1.74 / 2.24

1.74 / 2.24

1.74 / 2.24

1.74 / 2.24

2.44 / 3.13

22 + 22 + 22 + 22 + 22 + 22 + 60

1.60 / 2.06

1.60 / 2.06

1.60 / 2.06

1.60 / 2.06

1.60 / 2.06

1.60 / 2.06

4.38 / 5.63

22 + 22 + 25 + 25 + 25 + 25 + 25 + 25

1.59 / 2.04

1.59 / 2.04

1.80 / 2.32

1.80 / 2.32

1.80 / 2.32

1.80 / 2.32

1.80 / 2.32

1.80 / 2.32

22 + 22 + 22 + 22 + 22 + 25 + 25

1.93 / 2.48

1.93 / 2.48

1.93 / 2.48

1.93 / 2.48

1.93 / 2.48

2.19 / 2.81

2.19 / 2.81

22 + 25 + 25 + 25 + 25 + 25 + 25 + 25

1.56 / 2.01

1.78 / 2.28

1.78 / 2.28

1.78 / 2.28

1.78 / 2.28

1.78 / 2.28

1.78 / 2.28

1.78 / 2.28

22 + 22 + 22 + 22 + 22 + 25 + 35

1.81 / 2.33

1.81 / 2.33

1.81 / 2.33

1.81 / 2.33

1.81 / 2.33

2.06 / 2.65

2.88 / 3.71

25 + 25 + 25 + 25 + 25 + 25 + 25 + 25

1.75 / 2.25

1.75 / 2.25

1.75 / 2.25

1.75 / 2.25

1.75 / 2.25

1.75 / 2.25

1.75 / 2.25

1.75 / 2.25

22 + 22 + 22 + 22 + 22 + 25 + 50

1.66 / 2.14

1.66 / 2.14

1.66 / 2.14

1.66 / 2.14

1.66 / 2.14

1.89 / 2.43

3.78 / 4.86

22 + 22 + 22 + 22 + 22 + 25 + 60

1.58 / 2.03

1.58 / 2.03

1.58 / 2.03

1.58 / 2.03

1.58 / 2.03

1.79 / 2.31

4.31 / 5.54

22 + 22 + 22 + 22 + 22 + 35 + 35

1.71 / 2.20

1.71 / 2.20

1.71 / 2.20

1.71 / 2.20

1.71 / 2.20

2.72 / 3.50

2.72 / 3.50

22 + 22 + 22 + 22 + 22 + 35 + 50

1.58 / 2.03

1.58 / 2.03

1.58 / 2.03

1.58 / 2.03

1.58 / 2.03

2.51 / 3.23

3.59 / 4.62

22 + 22 + 22 + 22 + 25 + 25 + 25

1.89 / 2.43

1.89 / 2.43

1.89 / 2.43

1.89 / 2.43

2.15 / 2.76

2.15 / 2.76

2.15 / 2.76

22 + 22 + 22 + 22 + 25 + 25 + 35

1.78 / 2.29

1.78 / 2.29

1.78 / 2.29

1.78 / 2.29

2.02 / 2.60

2.02 / 2.60

2.83 / 3.64

22 + 22 + 22 + 22 + 25 + 25 + 50

1.64 / 2.11

1.64 / 2.11

1.64 / 2.11

1.64 / 2.11

1.86 / 2.39

1.86 / 2.39

3.72 / 4.79

22 + 22 + 22 + 22 + 25 + 25 + 60

1.56 / 2.00

1.56 / 2.00

1.56 / 2.00

1.56 / 2.00

1.77 / 2.27

1.77 / 2.27

4.24 / 5.45

22 + 22 + 22 + 22 + 25 + 35 + 35

1.68 / 2.16

1.68 / 2.16

1.68 / 2.16

1.68 / 2.16

1.91 / 2.46

2.68 / 3.44

2.68 / 3.44

22 + 22 + 22 + 22 + 25 + 35 + 50

1.56 / 2.00

1.56 / 2.00

1.56 / 2.00

1.56 / 2.00

1.77 / 2.27

2.47 / 3.18

3.54 / 4.55

22 + 22 + 22 + 22 + 35 + 35 + 35

1.60 / 2.05

1.60 / 2.05

1.60 / 2.05

1.60 / 2.05

2.54 / 3.26

2.54 / 3.26

2.54 / 3.26

22 + 22 + 22 + 25 + 25 + 25 + 25

1.86 / 2.39

1.86 / 2.39

1.86 / 2.39

2.11 / 2.71

2.11 / 2.71

2.11 / 2.71

2.11 / 2.71

22 + 22 + 22 + 25 + 25 + 25 + 35

1.75 / 2.25

1.75 / 2.25

1.75 / 2.25

1.99 / 2.56

1.99 / 2.56

1.99 / 2.56

2.78 / 3.58

22 + 22 + 22 + 25 + 25 + 25 + 50

1.61 / 2.07

1.61 / 2.07

1.61 / 2.07

1.83 / 2.36

1.83 / 2.36

1.83 / 2.36

3.66 / 4.71

22 + 22 + 22 + 25 + 25 + 25 + 60

1.53 / 1.97

1.53 / 1.97

1.53 / 1.97

1.74 / 2.24

1.74 / 2.24

1.74 / 2.24

4.18 / 5.37

22 + 22 + 22 + 25 + 25 + 35 + 35

1.66 / 2.13

1.66 / 2.13

1.66 / 2.13

1.88 / 2.42

1.88 / 2.42

2.63 / 3.39

2.63 / 3.39

22 + 22 + 22 + 25 + 25 + 35 + 50

1.53 / 1.97

1.53 / 1.97

1.53 / 1.97

1.74 / 2.24

1.74 / 2.24

2.44 / 3.13

3.48 / 4.48

22 + 22 + 22 + 25 + 35 + 35 + 35

1.57 / 2.02

1.57 / 2.02

1.57 / 2.02

1.79 / 2.30

2.50 / 3.21

2.50 / 3.21

2.50 / 3.21

22 + 22 + 25 + 25 + 25 + 25 + 25

1.82 / 2.34

1.82 / 2.34

2.07 / 2.66

2.07 / 2.66

2.07 / 2.66

2.07 / 2.66

2.07 / 2.66

22 + 22 + 25 + 25 + 25 + 25 + 35

1.72 / 2.21

1.72 / 2.21

1.96 / 2.51

1.96 / 2.51

1.96 / 2.51

1.96 / 2.51

2.74 / 3.52

22 + 22 + 25 + 25 + 25 + 25 + 50

1.59 / 2.04

1.59 / 2.04

1.80 / 2.32

1.80 / 2.32

1.80 / 2.32

1.80 / 2.32

3.61 / 4.64

22 + 22 + 25 + 25 + 25 + 35 + 35

1.63 / 2.10

1.63 / 2.10

1.85 / 2.38

1.85 / 2.38

1.85 / 2.38

2.59 / 3.33

2.59 / 3.33

22 + 22 + 25 + 25 + 35 + 35 + 35

1.55 / 1.99

1.55 / 1.99

1.76 / 2.26

1.76 / 2.26

2.46 / 3.17

2.46 / 3.17

2.46 / 3.17

22 + 25 + 25 + 25 + 25 + 25 + 25

1.79 / 2.30

2.03 / 2.62

2.03 / 2.62

2.03 / 2.62

2.03 / 2.62

2.03 / 2.62

2.03 / 2.62

22 + 25 + 25 + 25 + 25 + 25 + 35

1.69 / 2.18

1.92 / 2.47

1.92 / 2.47

1.92 / 2.47

1.92 / 2.47

1.92 / 2.47

2.69 / 3.46

22 + 25 + 25 + 25 + 25 + 25 + 50

1.56 / 2.01

1.78 / 2.28

1.78 / 2.28

1.78 / 2.28

1.78 / 2.28

1.78 / 2.28

3.55 / 4.57

22 + 25 + 25 + 25 + 25 + 35 + 35

1.60 / 2.06

1.82 / 2.34

1.82 / 2.34

1.82 / 2.34

1.82 / 2.34

2.55 / 3.28

2.55 / 3.28

22 + 25 + 25 + 25 + 35 + 35 + 35

1.52 / 1.96

1.73 / 2.23

1.73 / 2.23

1.73 / 2.23

2.43 / 3.12

2.43 / 3.12

2.43 / 3.12

25 + 25 + 25 + 25 + 25 + 25 + 25

2.00 / 2.57

2.00 / 2.57

2.00 / 2.57

2.00 / 2.57

2.00 / 2.57

2.00 / 2.57

2.00 / 2.57

25 + 25 + 25 + 25 + 25 + 25 + 35

1.89 / 2.43

1.89 / 2.43

1.89 / 2.43

1.89 / 2.43

1.89 / 2.43

1.89 / 2.43

2.65 / 3.41

25 + 25 + 25 + 25 + 25 + 25 + 50

1.75 / 2.25

1.75 / 2.25

1.75 / 2.25

1.75 / 2.25

1.75 / 2.25

1.75 / 2.25

3.50 / 4.50

25 + 25 + 25 + 25 + 25 + 35 + 35

1.79 / 2.31

1.79 / 2.31

1.79 / 2.31

1.79 / 2.31

1.79 / 2.31

2.51 / 3.23

2.51 / 3.23

Page 58

Page 59


MUZ-HC25/35VA(B)

>

Upper View

Side View

>

>

Front View

MUZ-GE25/35VA / MUZ-FD25/35VABH / SUZ-KA25/35VA2

>

>

>

Upper View

Side View

Side View

>

417.5

>

Air in

40

>

Air out 175

>

840

81

109

880

Front View

500

Outdoor Unit Dimensions

Front View

Side View

MUZ-GE60/71VA

330

Upper View

>

360

Front View

>

50

Upper View

MUZ-GE50VA / SUZ-KA50VA2

452

35

164.5

99.5

44

Dimensions

195

Page 60

M Series Range

Outdoor Units

Dimensions

Page 61


M Series Range

Accessories / Optional Extras M Series Catechin Filter

MAC-3003CF

- for MSZ-HC25/35VA(B) (10 pack)

Anti-Allergy Enzyme Filters

MAC-408FT-E MAC-2310FT-E MAC-415FT-E

- for MSZ-GE22-50VA (10 pack) - for MSZ-GE60/71VA (10 pack) - for MFZ-KA25-50VA (10 pack)

Wired Remote controller

PAR-30MAA

- for MSZ-GE22-71VA, MSZ-FD25/35VA & MFZ-KA25-50VA

Interfaces

MAC-399IF

- for connection to M-NET system

MAC-397IF

- for Contact Terminal, PAR-30MAA Wired Remote Controller

MAC-889SG

- for MXZ-2C52VA, MUZ-HC, MUZ-GE & MUZ-FD

MAC-856SG

- for MXZ-3C54VA, MXZ-4C71VA, MXZ-4C80VA & MXZ-5C100VA

Air Outlet Guides

PAC-SG59SG-E - for MXZ-8B140VA, MXZ-8B160YA

Accessories / Optional Extras

MXZ-8B Connection Pipe

Page 62

PAC-AK52YP-E - Y shaped pipe for MXZ-8B models enabling size 100 connection (PLA-RP)


Mr Slim Packaged Split-System Air Conditioning

Air Conditioning Commercial Heating Domestic Heating Photovoltaics


The Mr Slim Range Compact and Versatile, the Options are Endless

Easy to fit wherever you need

Suitable to heat or cool a huge variety of applications, the Mr Slim range is one of Britain’s best selling air conditioning split-systems. Combine the efficiency with the complete versatility that this range has to offer and the possibilities are virtually infinite. The 2011 Mr Slim range has been updated with new features, as well as the already impressive efficiency levels being improved. New to the range is an improved Standard Inverter offering, now also available as a 3-phase option. Complementing this, the Mr Slim Zubadan Inverter range of outdoor units guarantee heating operation down to -25ºC ambient air temperature, allowing set temperatures to be reached faster. The Mr Slim range has reached a new level of energy efficiency with the incorporation of new technologies and a new body design. These innovations will result in lower running costs and emissions throughout the life of a system. The side flow configuration of the outdoor unit, maximum piping length of 120m and Replace Technology help to simplify installation and make Mr Slim units more than just physically compact and discreet. They are also amongst the quietest operating units available, which means that apart from enjoying a comfortable, controllable environment, users hardly know Mr Slim is there at all.

An installers favourite, the excellent design of the Mr Slim range ensures quick and simple installation with the minimum of disruption. With extensive pipe runs of up to 120m, this versatile range makes it easier to select a layout to install the unit.

Page 64

Page 65


Power Inver ter

Silent Operation Operation has been made near-silent (67% quieter than corresponding R22 outdoor unit*1) as a result of improvement in the design of the fan blades and the new grille shape. The Power Inverter is even quieter at night when outside temperatures drop, as it can be set to low-noise mode (cooling only) reducing operating noise by 3dBA (50% quieter than normal day mode).

The Mr Slim Power Inverter range is now stronger than ever. The technological developments applied to this range of equipment offer the end user some of the highest energy efficiency ratings available, alongside greater application flexibility. This range is available in single and 3-phase options, the latter having running currents that are more than half that of the single phase option, offering a clear benefit to business premises that already have 3-phase supply installed. All models have low starting currents of 5 amps.

Improved COP / EER Ratings COP and EER ratings have increased across the board with the introduction of the VHA4 and VKA/YKA models. Many systems within our range now having energy labels of ‘A’ in both heating and cooling.

A low-noise priority function is also available by connecting a separate commercially available timer or selector switch. When a signal is received from the timer or switch, the unit automatically runs in low-noise mode.

Highly Efficient Fan and Grille

Existing R22/R407c Pipe Work

Outdoor Unit Fan Opening Increased <RP100-250> The diameter of the fan opening in the outdoor unit has been increased from 490 to 550mm. Discharge volume has been increased, while maintaining the same fan rotation speed.

The Mr Slim Power Inverter can reduce power consumption by up to 70% compared to a previously installed non-inverter model*1, making the energy cost savings associated with this range truly remarkable. A high power function also delivers increased capacity at times of high demand, allowing the room target temperature to be reached as rapidly as possible from start up.

When comparing the Power Inverter (PUHZ-RP71VHA4) with R22 (PUH3-VKA) in cooling.

The shapes of the fan and grille of the outdoor unit have been redesigned, realising an increase in discharge volume and a more efficient heat exchange, while maintaining the same operating noise level.

The issue of using existing pipe work has been resolved using Mitsubishi Electric’s unique ‘Replace Technology’, offering the opportunity to upgrade older, less efficient systems with the minimum of cost and installation disruption.

Reducing Power Consumption by 70%

*1

Grille Shape Changed

<RP60-250>

The shape of the air outlet grille has been changed to reduce pressure loss. This has helped improve heat exchange performance.

Highly Efficient Heat Exchanger A reduction in pipe diameter and an increase in surface area have improved the overall efficiency of the heat exchanger.

New Inflexed Fan

<RP100-250>

The adoption of a fan with improved ventilation characteristics and a newly designed rear edge that suppresses wind turbulence raises fan operation efficiency.

High-Density Heat Exchanger

Heat-Exchange Surface Area Increased <RP100-250> The heat exchanger size has been extended horizontally, increasing the surface area.

<RP100-250>

The pipe diameter for the RP100-140 has been changed from 9.52 to 7.94mm, the same diameter as that used for RP200-250 units, resulting in a high-density heat exchanger.

2 lines, 52 columns 2 lines, 64 columns

Increase in heat-exchanger surface area

Heat Interchanger Circuit (HIC) Added <RP140> *1 Based on the following operating conditions - Place-Office in Tokyo, Japan / Operating time-8am to 8pm, 6 days/week / Operating period-Cooling: April 16 - November 8. Heating: December 14 - March 23 / Set temperature-Cooling: 27°C, Heating: 20˚C. Non-inverter model installed eight years ago is a PLH-3GKHB / PUH-3YKA. Power Inverter model is a PLA-RP71BA2 / PUHZ-RP71VHA4.

Page 66

An HIC has been added to improve energy efficiency during cooling operation. Liquid refrigerant is rerouted, transformed into a gas state and injected back into the system to increase overall pressure of the refrigerant being sent to the compressor, thereby reducing the load on the compressor and raising efficiency.

Page 67


Standard Inverter The Standard Inverter models provide an inverter solution at a lower capital cost than the Power Inverter range. These outdoor models continue to offer high efficiency as standard, with some systems qualifying for Enhanced Capital Allowance. Models are available in 10, 12.5 & 14kW single phase and new for 2011, in 3-phase 10, 12.5, 14, 19 and 22kW sizes.

New 3-phase models now available

Improved COP / EER Figures

Improved Fan Design and Weight

COP / EER figures have been improved when compared to the previous R407c range.

The 10kW model has a compact single fan design and weighs less when compared to its Power Inverter equivalent, making installation easier.

SUZ outdoor units

are able to be connected to selected Mr Slim indoor units, creating a new range of low cost inverter driven systems.

Example: Height reduced by 395mm Power 116kg Inverter

Weight reduced by 41kg Standard 75kg Inverter

Low noise mode can be set at night time to reduce noise levels by 1/2 the audible sound approximately 50%. (compared to

330mm

daytime)

The example here is using a PUHZ-P100VHA3

Day 50dBA Outdoor Temperature 35ยบC

3dBA Less

943mm

Silent Outdoor Unit - Low Noise Mode

1338mm

395mm

1050mm

330mm

950mm

Duty Standby Operation

Night 47dBA Outdoor Temperature 25ยบC

Design with Environmental Consideration:

3 new functions are available with Mr Slim systems* : 1

Pump down switch Pushing a switch starts / stops refrigerant recovery operation automatically. This process will then be completed by closing a valve.

Rotate

Rotation 2 outdoor units (master & slave) operate alternately, switching every 1, 3, 5, 7, 14, 28 days (selectable).

Back Up

Back Up When master outdoor unit fails, sub unit begins operation.

Pump down switch

Join In

Join In When master outdoor unit fails to reach set temperature, sub unit operates in conjunction (available in cooling mode only).

Smooth refrigerant recovery can be assured by pushing the pump down switch at unit movement / renewal.

Page 68

* 1 Not available when using SUZ outdoor units. Must be used in conjunction with a PAR-30MAA controller.

Page 69


Mitsubishi Electric’s Flash Injection Technology

Zubadan Inverter The ZUBADAN Series incorporates Flash Injection Technology that improves the already high heating capacity of the system. This newest member of the Mr Slim range ensures comfortable heat pump-driven heating performance in colder regions.

A Heat Interchanger ( HIC )

Improved Heating Performance

Enhanced Comfort

Mitsubishi Electric’s unique “Flash Injection Circuit” achieves a remarkably high heating performance.

The Flash Injection Circuit improves start-up and recovery from defrost operation. A newly introduced defrost operation control also improves defrost frequency. These features enable the temperature to reach the set temperature more quickly and contribute to maintaining it at the desired setting.

This technology has resulted in an excellent heating capacity rating in outdoor temperatures as low as -15°C and the guaranteed heating operation range of the heating mode has been extended to -25°C. Accordingly, the Zubadan inverters are perfect for warming homes in the coldest of regions.

Flash Injection Circuit

The Key to High Heating Performance at Low Outdoor Temperatures The Zubadan Series is equipped with Mitsubishi Electric’s original Flash Injection Circuit, which is comprised of a bypass circuit and heat interchanger (HIC). The HIC transforms re-routed liquid refrigerant into a gas-liquid state to lower compression load. This process ensures excellent heating performance even when the outdoor temperature drops very low.

B Injection Compressor

In traditional units, when the outdoor temperature is low, the volume of refrigerant circulating in the compressor decreases due to the drop in refrigerant pressure and high compression (to protect from overheating), thereby reducing heating capacity. The Flash Injection Circuit injects refrigerant to maintain the refrigerant circulation volume and compressor operation load, thereby maintaining heating capacity.

Injection compressor (injection port)

Indoor HEX

Power receiver

B LEV A

LEV B LEV C

Refrigerant flow

A

Heat Interchanger (HIC)

B

Refrigerant doesn’t pass through LEV C

A

Heat interchanger (HIC)

Flash Injection Circuit

Injection Compressor Injection port

HIC cross-sectional view Refrigerant passes through LEV C (refrigerant pressure lowered)

Outdoor HEX

Refrigerant flow

Discharge port Suction port Normal refrigerant flow

ZUBADAN Defrost Control and Faster Recovery from Defrost Operation ■ Operation data for 25 Jan. 2005

■ Operation data for 2 Dec. 2004

60 °C

60°C

50 °C

50°C

40 °C

40°C

30 °C

30°C

20 °C

20°C

10 °C

10°C

0 °C

18:00

-10 °C -20 °C

20:00

22:00

0:00

2:00

4:00

6:00

0°C -10°C 8:00

10:00

12:00

14:00

16:00

18:00

20:00

22:00

-30 °C

Installation example

Field test results: Office building in Ashikawa, Hokkaido, Japan

Page 70

Purpose: Transform liquid refrigerant into liquid-gas state Effect: Injection circuit increases energy efficiency

The compressor is subjected to a heavy load when compressing liquid refrigerant, the result being lower operation efficiency. The addition of HIC supports refrigerant heat exchange at two different pressure levels. The heat-exchange process transforms the injected liquid refrigerant into a gas liquid state, thereby decreasing the load on the compressor during the compression process.

Purpose: To increase the volume of refrigerant being circulated Effect:

Improves heating capacity at low outdoor temperatures and enables higher indoor-air outlet temperature adjustment and higher defrost operation speed

Refrigerant passes from the HIC into the compressor through the injection port. Having two refrigerant inlets makes it possible to raise the volume of refrigerant being circulated when the outdoor temperature is low and at the start of heating operation.

Page 71


PLA-RP 4-Way Blow Cassette The PLA-RP-BA(2)(3) (PLFY-P-VBM-E for City Multi) 4-Way Blow Cassette, offers a range of new features, as well as a new design and pure white colour.

Wide Airflow

I New product

I Previous product

The wide shape vane (capable of wide angle air supply) provides comfort at the corners of a room, regardless of cooling or heating operation. A reduction in the air speed by 20% (compared to the previous product) eliminates the uncomfortable draft sensation often experienced.

Reduced Draft Air Distribution Reduced draft air distribution allows the vanes to supply airflow horizontally, thus preventing discomfort due to excessive cooling or from direct exposure of occupants to the air blow.

Independent Vane Control If the airflow direction needs to be changed as a result of an altered room layout or due to the mode selected (i.e. cooling or heating), the air direction of each vane can be set independently using the PAR-30MAA wired remote controller.

Reduced Draft Air Distribution

Horizontal blow PAR-30MAA Adjustable

Fixed

Down blow

Automatic Airflow Adjustment Mode The automatic airflow adjustment mode is provided in addition to the 4 normal airflow stages and allows automatic adjustment of the airflow in accordance with the difference between the set temperature and the room temperature.

Grille with Automatic Filter Lowering Function (Optional) This grille can be operated by both the wired remote controller and the exclusive infra-red remote controller. It can be lowered in 8 steps down to 4m in accordance with the ceiling height, enabling you to easily clean the air filter. Regular cleaning of the filter is an important factor in saving energy.

Automatic lowering to

4m

For example: The automatic airflow adjustment mode allows quick cooling of a room using high mode, then when the room temperature has stabilised, the low mode will be applied to maximise comfort. Low

Page 72

Medium 1

Medium 2

High

Automatic airflow adjustment

Elevation Grille Remote Controller (comes with the grille)

PAR-30MAA Wired Remote Controller

Page 73


PLA-RP 4-Way Blow Cassette

“Sensible Temperature Control” to Prevent Excessive Cooling and Heating

The (optional corner panel) Provides Even Temperature Distribution and Reduces Energy Consumption

By measuring the inlet temperature and floor temperature, a temperature felt by the human body (sensible temperature) will be calculated and maintained, suppressing excessive cooling and heating.

The “I-See Sensor” uses temperature sensing technology developed by Mitsubishi Electric. In order to create a comfortable environment in shops and offices, it is essential to control the temperature near the floor where occupants and visitors gather. The “I-See Sensor” measures the infra-red rays generated from the surrounding wall and floor surfaces and converts these into temperature values.

360°

In addition, floor temperatures are also measured at distant spots, allowing optimum airflow to reach these areas.

The "I-See Sensor" rotates to measure the floor temperature

I “I-See Sensor”operation: The “I-See Sensor”rotates slowly in intervals of 5 seconds, correctly measuring the temperature of the entire floor space.

5 seconds

5 seconds

5 seconds

5 seconds

In the past...

only the inlet temperature near the ceiling was measured, tending to overlook the uneven temperature distribution near the floor. Conventional air conditioning in shops and offices only measured the temperature near to the ceiling, therefore the uneven temperature distribution between the ceiling and the floor remained unchecked.

With “I-See Sensor”... both the floor temperature and inlet temperature are measured.

The 4-Way Blow Ceiling Cassette with the “I-See Sensor” simultaneously measures the floor and inlet temperatures, providing improved comfort to occupants and increased energy savings.

As a result, the set temperature tended to be higher in order to obtain comfort at floor level. Without “I-See Sensor”. Set temperature is 23ºC (in Heating)

Inlet temperature sensor

Area measured by cassette model without "I-See Sensor"

e.g. To achieve a sensible temperature of 20ºC, the set temperature must be as high as 23ºC

Page 74

With the “I-See Sensor” plus automatic airflow adjustment mode. Set temperature is 20ºC (in Heating)

Inlet temperature sensor

360° sensing

Area measured by the cassette model equipped with "I-See Sensor"

2.7m

e.g. With the set temperature at 20ºC, a sensible temperature of 20ºC at floor level can be obtained.

37ºC

37ºC

25ºC

25ºC

13ºC

13ºC

Page 75


The Adaptable Mr Slim Range

Designed to fit anywhere Available in a variety of options, the Mr Slim range fits in wherever it’s needed. Indoor units can be four way blow cassettes, ducted, floor, wall or ceiling mounted. Up to four indoor units can then be connected to a single outdoor unit providing the ideal air conditioning solution.

Simple technology at its best

Contents 78

PKA-RP Power Inverter Heat Pump, Wall Mounted System

80

PKA-RP Standard Inverter Heat Pump, Wall Mounted System

82

PKA-RP Zubadan Inverter Heat Pump, Wall Mounted System

84

PKA-RP Power Inverter Heat Pump, High SHF Wall Mounted System

86

SEZ-KD-VAQ Inverter Heat Pump, Ceiling Concealed Ducted System

88

PEAD-RP Power Inverter Heat Pump, Ceiling Concealed Ducted System

90

PEAD-RP Standard Inverter Heat Pump, Ceiling Concealed Ducted System

92

PEAD-RP Zubadan Inverter Heat Pump, Ceiling Concealed Ducted System

94

PEA-RP-GAQ Power Inverter Heat Pump, Large Capacity Ceiling Concealed Ducted System

96

PEA-RP-GAQ Standard Inverter Heat Pump, Large Capacity Ceiling Concealed Ducted System

98

SLZ-KA-VAQ Inverter Heat Pump, 600x600 4-Way Blow Ceiling Cassette System

100

PLA-RP Power Inverter Heat Pump, 4-Way Blow Ceiling Cassette System

102

PLA-RP Standard Inverter Heat Pump, 4-Way Blow Ceiling Cassette System

104

PLA-RP Zubadan Inverter Heat Pump, 4-Way Blow Ceiling Cassette System

106

PCA-RP Power Inverter Heat Pump, Ceiling Suspended System

108

PCA-RP Standard Inverter Heat Pump, Ceiling Suspended System

110

PCA-RP-HAQ Power Inverter Heat Pump, Stainless Steel Ceiling Suspended System

112

PCA-RP-HAQ Standard Inverter Heat Pump, Stainless Steel Ceiling Suspended System

114

PSA-RP Power Inverter Heat Pump, Floor Standing System

116

PSA-RP Standard Inverter Heat Pump, Floor Standing System

118

PHV DXE Heat Pump, Air Curtain

120

PHV NT Chilled Water Heat Pump, Sensible Cooling Wall Mounted System

122

Mr Slim Multi-Split Systems Heat Pump

124

Outdoor Units

130

Air Handling Unit Controller

131

Mr Slim Accessories / Optional Extras

Many of our systems have an energy label of A, are registered on the Energy Technology List and hence qualify for 100% first year enhanced capital allowances (whole system cost and ‘reasonable’ cost of installation). For further information please go to www.eca.gov.uk

Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB. Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB. UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. UK Conditions: Winter; indoor 21˚C DB; outdoor -1˚C WB.

Page 76

Page 77


Dimensions

Wall Mounted System Flat panel, compact indoor unit design

I

Adjustable louvres for uniform air distribution

I

Internal pipe connection to wall mounted unit for easy and neat installation

Front View

>

Side View

>

295

I

INDOOR UNIT PKA-RP35-50HAL

55

688

155

Mr Slim Range

PKA-RP Power Inverter Heat Pump

5

249

898

Technical Information PKA-RP - INDOOR UNITS PKA-RP50HAL

PKA-RP60KAL

PKA-RP71KAL

PKA-RP100KAL

4.1 (1.6-5.2)

5.0 (2.5-7.3)

7.0 (2.8-8.2)

8.0 (3.5-10.2)

11.2 (4.5-14.0)

Cooling (nominal)

3.6 (1.6-4.5)

4.6 (2.3-5.6)

6.0 (2.7-6.7)

7.1 (3.3-8.1)

10.0 (4.9-11.4)

Heating (UK)

3.5 (1.35-4.4)

4.25 (2.15-6.2)

5.95 (2.4-6.95)

6.8 (3.0-8.65)

9.5 (3.85-11.9)

Cooling (UK)

3.3 (1.45-4.15)

4.25 (2.1-5.15)

5.5 (2.5-6.15)

6.55 (3.05-7.45)

9.2 (4.5-10.5)

SHF (nominal & UK)

0.81

0.72

0.86

0.78

0.73

COP / EER (nominal)

3.63 / 3.67

3.62 / 3.22

3.98 / 3.90

3.76 / 3.62

3.61 / 3.45

A /A

A /A

A /A

A /A

A /A

ENERGy LABEL

Heating/Cooling

AIRFLOW (m3/min)

Lo-Mi-Hi

9-10.5-12

9-10.5-12

18-20-22

18-20-22

20-23-26

PIPE SIZE mm(in)

Gas

12.7 (1/2”)

12.7 (1/2”)

15.88 (5/8”)

15.88 (5/8”)

15.88 (5/8”)

Liquid

6.35 (1/4”)

6.35 (1/4”)

9.52 (3/8”)

9.52 (3/8”)

9.52 (3/8”)

36-40-43

36-40-43

39-42-45

39-42-45

41-45-49

NOISE (dBA)

Lo-Mi-Hi

DIMENSIONS (mm)

Width

898

898

1170

1170

1170

Depth

249

249

295

295

295

Height

295

295

365

365

365

13

13

21

21

21

Fed by Outdoor Unit

Fed by Outdoor Unit

Fed by Outdoor Unit

Fed by Outdoor Unit

Fed by Outdoor Unit

Single

Single

Single

Single

Single

FUSE RATING (BS88) – HRC (A)

6

6

6

6

6

INTERCONNECTING CABLE No. CORES

4

4

4

4

4

PUHZ-RP35VHA4

PUHZ-RP50VHA4

PUHZ-RP60VHA4

PUHZ-RP71VHA4

PUHZ-RP100VKA/YKA

46 / 44 (41)

46 / 44 (41)

48 / 47 (44)

48 / 47 (44)

51 / 49 (46) 116 / 124

WEIGHT (kg) ELECTRICAL SUPPLy PHASE

INDOOR UNIT PKA-RP60-100KAL

Front View

>

Side View

> PKA-RP Power Inverter Heat Pump

PKA-RP35HAL Heating (nominal)

CAPACITy (kW)

365

MODEL REFERENCE

PUHZ-RP - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)

Heating/Cooling (silent)

WEIGHT (kg) DIMENSIONS (mm)

42

42

67

67

Width

800

800

950

950

1050

Depth

300 + 23

300 + 23

330 + 30

330 + 30

330 + 30

Height ELECTRICAL SUPPLy PHASE SySTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SySTEM RUNNING CURRENT (A) Single Phase Heating/Cooling

[MAX]

3 Phase

600

600

943

943

1338

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz / 380-415v,50Hz

Single

Single

Single

Single

Single / 3

1.13 / 0.98

1.38 / 1.43

1.76 / 1.54

2.13 / 1.96

3.10 / 2.90

1.01 / 0.83

1.23 / 1.22

1.57 / 1.31

1.90 / 1.67

2.76 / 2.47

5

5

5

5

5

5.33 / 4.66 [13.4]

6.45 / 6.68 [13.4]

8.09 / 7.11 [19.4]

9.75 / 8.99 [19.4]

14.15 / 13.25 [27.1]

-

-

-

-

5.32 / 5.01 [8.6]

FUSE RATING (BS88) - HRC (A)

16

16

20

20

32 / 10

MAINS CABLE No. Cores

3

3

3

3

3/5

MAX PIPE LENGTH (m)

50

50

50

50

75

MAX HEIGHT DIFFERENCE (m)

30

30

30

30

30

CHARGE R410A (kg) - 30m

2.5

2.5

3.5

3.5

5.0

Page 78

74

(855)

241

295

5

1170

Page 79


Wall Mounted System

Dimensions

INDOOR UNIT PKA-RP100KAL

The Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the Power Inverter range. I

Flat panel, compact indoor unit design

I

Adjustable louvres for uniform air distribution

I

Internal pipe connection to wall mounted unit for easy and neat installation

I

3-phase Standard Inverters now available

>

Side View

>

365

Front View

74

(855)

241

295

Mr Slim Range

PKA-RP Standard Inverter Heat Pump

5

1170

Technical Information PKA-RP - INDOOR UNITS MODEL REFERENCE CAPACITy (kW)

PKA-RP100KAL Heating (nominal) Cooling (nominal)

11.2 (4.5-12.5) 9.4 (4.9-11.2)

Heating (UK)

9.5 (3.85-10.65)

Cooling (UK)

8.65 (4.5-10.3)

SHF (nominal & UK)

0.75

COP / EER (nominal)

3.21 / 3.01

ENERGy LABEL

Heating/Cooling

AIRFLOW (m3/min)

Lo-Mi-Hi

PIPE SIZE mm(in)

Gas

15.88 (5/8”)

Liquid

9.52 (3/8”)

C/B 20-23-26

NOISE (dBA)

Lo-Mi-Hi

DIMENSIONS (mm)

Width

1170

Depth

295

Height

365

WEIGHT (kg)

41-45-49

21

ELECTRICAL SUPPLy PHASE

PKA-RP Standard Inverter Heat Pump

Fed by Outdoor Unit Single

FUSE RATING (BS88) - HRC (A)

6

INTERCONNECTING CABLE No. CORES

4

PUHZ-P - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)

PUHZ-P100VHA3/YHA Heating/Cooling (silent)

WEIGHT (kg)

54 / 50 (47) 75 / 77

DIMENSIONS (mm)

Width

950

Depth

330 + 30

Height ELECTRICAL SUPPLy

943 220-240v, 50Hz / 380-415v, 50Hz

PHASE

Single / 3

SySTEM POWER INPUT (kW)

Heating/Cooling (nominal)

3.49 / 3.12

Heating/Cooling (UK)

3.11 / 2.65

STARTING CURRENT (A)

8/3

SySTEM RUNNING CURRENT (A)

Single Phase

Heating/Cooling

3 Phase

[MAX]

FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m)

14.81 / 14.15 [28.6] 5.65 / 5.06 [13.6] 32 / 16 3/5 50

MAX HEIGHT DIFFERENCE (m)

30

CHARGE R410A (kg) - 20m

3.0

Page 80

Page 81


Wall Mounted System

Dimensions

INDOOR UNIT PKA-RP100KAL

Zubadan sets a new standard in performance The Mr Slim Zubadan Inverter heat pumps achieve an excellent heating performance even when the outdoor air temperature is as low as -25ºC. Flat panel, compact indoor unit design

I

Stable Heating Performance - Full heating capacity at -15°C, a 30% capacity improvement over the next size up Power Inverter

I

Expanded Heating Operation - Will work effectively even when the outdoor ambient air temperature is -25°C

I

Stable Operation - Utilising the new Flash Injection Circuit the Zubadan models have reduced defrost times and can provide continuous heating for up to 150 mins

I

Front View

>

Side View

>

365

I

74

(855)

241

295

Mr Slim Range

PKA-RP Zubadan Inver ter Heat Pump

5

1170

Quick Start-Up - At -20ºC, full heating capacity is achieved in about 20 mins, improving comfort levels

Technical Information PKA-RP - INDOOR UNITS MODEL REFERENCE CAPACITy (kW)

PKA-RP100KAL Heating (nominal) Cooling (nominal)

11.2 (4.5-14.0) 10.0 (4.9-11.4)

Heating (UK)

11.1 (4.45-13.85)

Cooling (UK)

9.2 (4.5-10.5)

SHF (nominal & UK)

0.73

COP / EER (nominal)

3.61 / 3.41

ENERGy LABEL

Heating/Cooling

AIRFLOW (m3/min)

Lo-Mi-Hi

PIPE SIZE mm(in)

Gas

15.88 (5/8”)

Liquid

9.52 (3/8”)

A /A 20-23-26

NOISE (dBA)

Lo-Mi-Hi

DIMENSIONS (mm)

Width

1170

Depth

295

Height

365

WEIGHT (kg)

41-45-49

PKA-RP Zubadan Inverter Heat Pump

21

ELECTRICAL SUPPLy

Fed by Outdoor Unit

PHASE

Single

FUSE RATING (BS88) – HRC (A)

6

INTERCONNECTING CABLE No. CORES

4

PUHZ-HRP - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)

PUHZ-HRP100VHA2/YHA2 Heating/Cooling (silent)

WEIGHT (kg)

52 / 51 (48) 120 / 134

DIMENSIONS (mm)

Width

950

Depth

330 + 30

Height ELECTRICAL SUPPLy

1350 220-240v, 50Hz / 380-415v, 50Hz

PHASE

Single / 3

SySTEM POWER INPUT (kW)

Heating/Cooling (nominal)

3.10 / 2.93

Heating/Cooling (UK)

4.50 / 2.49

STARTING CURRENT (A)

14 / 3

SySTEM RUNNING CURRENT (A)

Single Phase

Heating/Cooling

3 Phase

[MAX]

FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m)

14.15 / 13.39 [35.6] 5.32 / 5.06 [13.6] 40 / 16 3/5 75

MAX HEIGHT DIFFERENCE (m)

30

CHARGE R410A (kg) - 30m

5.5

Page 82

Page 83


High SHF Wall Mounted System

Dimensions

INDOOR UNIT PKA-RP100KAL

This new connection provides a low cost split system solution to high sensible applications such as server rooms and laboratories. High SHF system for use in server rooms and laboratories Flat panel, compact indoor unit design Adjustable louvres for uniform air distribution Internal pipe connection to wall mounted unit for easy and neat installation Duty Standby Operation available using multiple outdoor units (via PAR-30MAA) Able to connect to Run Standby Panel PANEL_RS_SMS (via Procon A1M). A maximum of 8 indoor units can be connected in this way, see page 306 for further information Gravity drain to rear of indoor unit for safe installation and operation

I I I I I

I

Front View

>

Side View

>

365

I

74

(855)

241

295

Mr Slim Range

PKA-RP Power Inverter Heat Pump

5

1170

Technical Information PKA-RP - INDOOR UNITS MODEL REFERENCE SHF

PKA-RP100KAL Cooling

6.0

(35ºC outdoor / 27ºC DB indoor, 47% relative humidity)

0.94

SHF

(35ºC outdoor / 24ºC DB indoor, 45% relative humidity)

0.96

EER

(35ºC outdoor / 27ºC DB indoor, 47% relative humidity)

4.29

EER

(35ºC outdoor / 24ºC DB indoor, 45% relative humidity)

3.75

ENERGy LABEL

Cooling

A

AIRFLOW (m3/min)

Lo-Mi-Hi

20-23-26

PIPE SIZE mm(in)

Gas

15.88 (5/8”)

Liquid

9.52 (3/8”)

PKA-RP Power Inverter Heat Pump (High SHF)

CAPACITy (kW)

41-45-49

NOISE (dBA)

Lo-Mi-Hi

DIMENSIONS (mm)

Width

1170

Depth

295

Height

365 21

WEIGHT (kg)

Fed by Outdoor Unit

ELECTRICAL SUPPLy

Single

PHASE FUSE RATING (BS88) - HRC (A)

6

INTERCONNECTING CABLE No. CORES

4

PUHZ-RP - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)

PUHZ-RP60VHA4 Heating/Cooling (silent)

WEIGHT (kg) DIMENSIONS (mm)

48 / 47 (44) 67

Width

950

Depth

330 + 30

Height ELECTRICAL SUPPLy PHASE

943 220-240v, 50Hz Single

SySTEM POWER INPUT (kW) Cooling

(35ºC outdoor / 27ºC DB indoor, 47% relative humidity)

1.4

Cooling

(35ºC outdoor / 24ºC DB indoor, 45% relative humidity)

1.6

STARTING CURRENT (A) MAX SySTEM RUNNING CURRENT (A) FUSE RATING (BS88) - HRC (A)

5 19.6 20

MAINS CABLE No. Cores

3

MAX PIPE LENGTH (m)

50

MAX HEIGHT DIFFERENCE (m)

30

CHARGE R410A (kg) - 20m

3.5

Page 84

Page 85


Dimensions INDOOR UNIT SEZ-KD25-71VAQ

Ceiling Concealed Ducted System

Upper View

Designed for homes, offices, restaurants or shops, the SEZ-KD-VAQ series operates at low noise levels. Its new improved low unit height and lightweight design also help to make installation easier and more convenient.

Note: Optional interfaces for M-NET connectivity (MAC-399IF) and group control, fault/run (MAC-397IF) are available. Please see accessories / optional extras section.

>

Mr Slim Range

SEZ-KD-VAQ Inverter Heat Pump

Technical Information

SEZ-KD-VAQ - INDOOR UNITS CAPACITy (kW)

SEZ-KD25VAQ

SEZ-KD35VAQ

SEZ-KD50VAQ

SEZ-KD60VAQ

SEZ-KD71VAQ

Heating (nominal)

3.0 (0.9-4.5)

4.2 (0.9-5.0)

6.4 (1.1-7.2)

7.4 (0.9-8.0)

8.1 (0.9-10.4)

Cooling (nominal)

2.5 (0.9-3.2)

3.7 (1.0-3.9)

5.1 (1.1-5.6)

5.6 (1.1-6.3)

7.1 (0.9-8.3)

Heating (UK)

2.5 (0.75-3.75)

3.5 (0.75-4.15)

5.3 (0.9-6.0)

6.15 (0.75-6.65)

6.75 (0.75-8.65)

Cooling (UK)

7.05 (0.9-8.25)

2.5 (0.9-3.15)

3.65 (1.0-3.85)

5.05 (1.1-5.55)

5.55 (1.1-6.25)

SHF (nominal & UK)

0.80

0.78

0.76

0.79

0.74

COP / EER (nominal)

3.61 / 3.33

3.72 / 3.39

3.54 / 3.11

3.51 / 3.01

3.72 / 3.01

ENERGy LABEL

Heating/Cooling

AIRFLOW (m3/min)

Lo-Mi-Hi

A /A

B/B

B/B

A/B

7-9-11

10-12.5-15

12-15-18

12-16-20

5-15-35-50

5-15-35-50

5-15-35-50

5-15-35-50

5-15-35-50

Gas

9.52 (3/8”)

9.52 (3/8”)

12.7 (1/2”)

15.88 (5/8”)

15.88 (5/8”)

Liquid

6.35 (1/4”)

6.35 (1/4”)

6.35 (1/4”)

6.35 (1/4”)

9.52 (3/8”)

23-26-30

23-28-33

30-34-37

30-34-38

30-35-40

EXTERNAL STATIC PRESSURE (Pa) PIPE SIZE mm(in)

A /A 6.0-7.0-9.0

Lo-Mi1-Mi2-Hi

NOISE (dBA) (15Pa)

Lo-Mi-Hi

DIMENSIONS (mm)

Width

790

990

990

1190

1190

Depth

700

700

700

700

700

Height

200

200

200

200

200

18

21

23

27

27

Fed by Outdoor Unit

Fed by Outdoor Unit

Fed by Outdoor Unit

Fed by Outdoor Unit

Fed by Outdoor Unit

Single

Single

Single

Single

Single

FUSE RATING (BS88) - HRC (A)

6

6

6

6

6

INTERCONNECTING CABLE No. CORES

4

4

4

4

4

SUZ-KA25VA2

SUZ-KA35VA2

SUZ-KA50VA2

SUZ-KA60VA2

SUZ-KA71VA2

46 / 46

48 / 47

55 / 53

55 / 53

55 / 55

33

37

53

53

53

Width

800

800

840

840

840

Depth

285

285

330

330

330

Height

550

550

850

850

880

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz

WEIGHT (kg) ELECTRICAL SUPPLy PHASE

Front View

Side View

>

> SEZ-KD-VAQ Inverter Heat Pump

MODEL REFERENCE

SUZ-KA-VA2 - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)

Heating/Cooling

WEIGHT (kg) DIMENSIONS (mm)

ELECTRICAL SUPPLy PHASE SySTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SySTEM RUNNING CURRENT (A) [MAX] Heating/Cooling FUSE RATING (BS88) - HRC (A)

Single

Single

Single

Single

Single

0.83 / 0.75

1.13 / 1.09

1.81 / 1.64

2.11 / 1.86

2.18 / 2.36

0.76 / 0.60

1.03 / 0.87

1.65 / 1.31

1.92 / 1.49

1.98 / 1.89

3.65

4.75

6.75

9.75

8.89

4.05 / 3.45 [8.6]

5.25 / 5.05 [9.7]

7.05 / 7.45 [16.7]

10.45 / 9.05 [16.7]

9.85 / 9.75 [17.0]

10

10

20

20

20

MAINS CABLE No. CORES

3

3

3

3

3

MAX PIPE LENGTH (m)

20

20

30

30

30

MAX HEIGHT DIFFERENCE (m)

12

12

30

30

30

CHARGE R410A (kg) - 7m

0.8

1.05

1.6

1.8

1.8

Page 86

Models

A

B

C

D

E

F

Size 25

700

752

798

660

7

600

Size 35-50

900

952

998

860

9

800

Size 60-71

1100

1152

1198

1060

11

1000

Page 87


Dimensions

Ceiling Concealed Ducted System I

Reduced height - entire range now only 250mm

I

Wider range of external static pressure settings across entire range

I

Reduced noise levels thanks to the use of a newly designed centrifugal fan as low as 23dBA

>

Front View

40

58

15

I

INDOOR UNIT PEAD-RP35-140JAQ

Drain pump included as standard 57 20

Air outlet

>

100 10

Upper View

D (Duct) 100x(E-1)=F

30

Mr Slim Range

PEAD-RP Power Inverter Heat Pump

57 643(Suspension bolt pitch)

Technical Information PEAD-RP - INDOOR UNITS MODEL REFERENCE

PEAD-RP35JAQ PEAD-RP50JAQ PEAD-RP60JAQ PEAD-RP71JAQ PEAD-RP100JAQ PEAD-RP125JAQ PEAD-RP140JAQ 7.0 (2.8-8.2)

8.0 (3.5-10.2)

11.2 (4.5-14.0)

14.0 (5.0-16.0)

5.0 (2.3-5.6)

6.0 (2.7-6.7)

7.1 (3.3-8.1)

10.0 (4.9-11.4)

12.5 (5.5-14.0)

14.0 (6.2-15.3)

Heating (UK)

3.5 (1.35-4.4)

5.1 (2.15-6.2)

5.95 (2.4-6.95)

6.8 (3.0-8.65)

9.5 (3.85-11.9)

11.9 (4.25-13.6)

13.6 (4.85-15.3)

Cooling (UK)

3.3 (1.45-4.15)

4.6 (2.1-5.15)

5.5 (2.5-6.15)

6.55 (3.05-7.45)

9.2 (4.5-10.5)

11.5 (5.05-12.9)

12.9 (5.7-14.1)

16.0 (5.7-18.0)

0.84

0.83

4.12 / 3.61

4.00 / 3.24

3.96 / 3.21

ENERGy LABEL

Heating/Cooling

AIRFLOW (m3/min)

Lo-Mi-Hi

PIPE SIZE mm(in)

Gas Liquid

EXTERNAL STATIC PRESSURE (Pa) Lo-Mi1-Mi2-Mi3-Hi

A /A

A /A

A /A

A /A

A /A

A /A

A /A

10-12-14

12-14.5-17

14.5-18-21

17.5-21-25

24-29-34

29.5-33.5-42

32-39-46

12.7 (1/2”)

12.7 (1/2”)

15.88 (5/8”)

15.88 (5/8”)

15.88 (5/8”)

15.88 (5/8”)

15.88 (5/8”)

6.35 (1/4”)

6.35 (1/4”)

9.52 (3/8”)

9.52 (3/8”)

9.52 (3/8”)

9.52 (3/8”)

9.52 (3/8”)

35-50-70-100-150

35-50-70-100-150

35-50-70-100-150

35-50-70-100-150

35-50-70-100-150

35-50-70-100-150

35-50-70-100-150

NOISE (dBA) (50Pa)

Lo-Mi-Hi

23-27-30

26-31-35

25-29-33

26-30-34

29-34-38

33-36-40

34-38-43

DIMENSIONS (mm)

Width

900

900

1100

1100

1400

1400

1600

Depth

732

732

732

732

732

732

732

Height

250

250

250

250

250

250

250

26

28

33

33

41

43

47

WEIGHT (kg)

Single

Single

Single

Single

Single

Single

Single

FUSE RATING (BS88) - HRC (A)

6

6

6

6

6

6

6

INTERCONNECTING CABLE No. CORES

4

4

4

4

4

4

4

PHASE

PUHZ-RP - OUTDOOR UNITS MODEL REFERENCE

PUHZ-RP35VHA4 PUHZ-RP50VHA4 PUHZ-RP60VHA4 PUHZ-RP71VHA4 PUHZ-RP100VKA/YKA PUHZ-RP125VKA/YKA PUHZ-RP140VKA/YKA Heating/Cooling (silent)

46 / 44 (41)

46 / 44 (41)

48 / 47 (44)

48 / 47 (44)

51 / 49 (46)

52 / 50 (47)

52 / 50 (47)

42

42

67

67

116 / 124

116 / 126

118 / 132

Width

800

800

950

950

1050

1050

1050

Depth

300 + 23

300 + 23

330 + 30

330 + 30

330 + 30

330 + 30

330 + 30

Height

600

600

943

943

1338

1338

1338

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz

WEIGHT (kg) DIMENSIONS (mm)

ELECTRICAL SUPPLy PHASE SySTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SySTEM RUNNING CURRENT (A) Single Phase Heating/Cooling

[MAX]

3 Phase

D

732 700

Side View

>

238

Drain pipe Drain pump (O.D. 32)

10

136

67 356

Drain pipe (Spontaneous draining)

220-240v, 50Hz / 380-415v,50Hz 220-240v, 50Hz / 380-415v,50Hz 220-240v, 50Hz / 380-415v,50Hz

Single

Single

Single

Single

Single / 3

Single / 3

Single / 3

1.10 / 1.02

1.56 / 1.55

1.75 / 1.60

2.00 / 2.03

2.72 / 2.77

3.50 / 3.86

4.04 / 4.36

0.98 / 0.87

1.39 / 1.32

1.56 / 1.36

1.78 / 1.73

2.42 / 2.35

3.12 / 3.28

3.60 / 3.71

5

5

5

5

5

5

5

5.15 / 4.81 [14.1]

7.38 / 7.35 [14.4]

8.29 / 7.63 [20.6]

9.46 / 9.62 [21]

12.73 / 12.98 [29.2] 16.45 / 18.09 [29.3] 18.94 / 20.39 [30.8]

-

-

-

-

5.48 / 5.63 [10.7]

7.25 / 7.89 [12.3]

8.25 / 8.83 [13.8]

FUSE RATING (BS88) - HRC (A)

16

16

25

25

32 / 16

32 / 16

32 / 16

MAINS CABLE No. Cores

3

3

3

3

3/5

3/5

3/5

MAX PIPE LENGTH (m)

50

50

50

50

75

75

75

MAX HEIGHT DIFFERENCE (m)

30

30

30

30

30

30

30

CHARGE R410A (kg) - 30m

2.5

2.5

3.5

3.5

5.0

5.0

5.0

Page 88

>

32

Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit

ELECTRICAL SUPPLy

NOISE (dBA)

Rear View

217

0.82

4.00 / 3.50

122

0.83

4.00 / 3.75

33

0.83

3.85 / 3.23

23 40

0.84

3.73 / 3.53

100

0.85

COP / EER (nominal)

B(Suspension bolt pitch) C

178(Duct)

SHF (nominal & UK)

A 23

PEAD-RP Power Inverter Heat Pump

6.0 (2.5-7.3)

3.6 (1.6-4.5)

250

4.1 (1.6-5.2)

Cooling (nominal)

41

Heating (nominal)

Air inlet

CAPACITy (kW)

Model

A

B

C

D

900 954 1000 860 PEAD-RP60-71JAQ 1100 1154 1200 1060 PEAD-RP100-125JAQ 1400 1454 1500 1360 PEAD-RP140JAQ 1600 1654 1700 1560 PEAD-RP35-50JAQ

E 9 11 14 16

F

G

800 858 1000 1058 1300 1358 1500 1558

Page 89


Ceiling Concealed Ducted System

INDOOR UNIT PEAD-RP35-140JAQ

The Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the Power Inverter range. I

Reduced height - entire range now only 250mm

I

Wider range of external static pressure settings across entire range

I

Reduced noise levels thanks to the use of a newly designed centrifugal fan - as low as 23dBA

I

Drain pump included as standard

>

Front View

40

15

58

57 20

Upper View

>

Air outlet

3-phase Standard Inverters now available

D (Duct) 100x(E-1)=F

30 100 10

I

Dimensions

Mr Slim Range

PEAD-RP Standard Inverter Heat Pump

57 643(Suspension bolt pitch)

Technical Information PEAD-RP - INDOOR UNITS PEAD-RP35JAQ PEAD-RP50JAQ PEAD-RP60JAQ PEAD-RP71JAQ PEAD-RP100JAQ PEAD-RP125JAQ PEAD-RP140JAQ

13.6 (5.5-15.0)

Heating (UK)

3.4 (0.75-4.15)

4.9 (0.75-6.0)

5.8 (0.75-6.65)

6.65 (0.75-8.5)

9.5 (3.85-10.65)

11.9 (4.25-13.6)

13.6 (4.25-15.3)

Cooling (UK)

3.55 (1.0-3.85)

4.85 (1.1-5.55)

5.65 (1.1-6.25)

7.05 (0.9-8.05)

8.65 (4.5-10.3)

11.3 (5.05-12.9)

12.5 (5.05-13.8)

SHF (nominal & UK)

0.85

0.85

0.86

0.83

0.85

0.85

0.84

COP / EER (nominal)

3.69 / 3.40

3.64 / 3.22

3.61 / 3.39

3.92 / 3.38

3.61 / 3.09

3.62 / 2.91

3.61 / 3.01

ENERGy LABEL

Heating/Cooling

AIRFLOW (m3/min)

Lo-Mi-Hi

PIPE SIZE mm(in)

Gas Liquid

EXTERNAL STATIC PRESSURE (Pa) Lo-Mi1-Mi2-Mi3-Hi

A /A

A /A

A /A

A /A

A/B

A/C

A/B

10-12-14

12-14.5-17

14.5-18-21

17.5-21-25

24-29-34

29.5-35.5-42

32-39-46

9.52 (3/8”)

12.7 (1/2”)

15.88 (5/8”)

15.88 (5/8”)

15.88 (5/8”)

15.88 (5/8”)

15.88 (5/8”)

6.35 (1/4”)

6.35 (1/4”)

6.35 (1/4”)

9.52 (3/8”)

9.52 (3/8”)

9.52 (3/8”)

9.52 (3/8”)

35-50-70-100-150

35-50-70-100-150

35-50-70-100-150

35-50-70-100-150

35-50-70-100-150

35-50-70-100-150

35-50-70-100-150

NOISE (dBA) (50Pa)

Lo-Mi-Hi

23-27-30

26-31-35

25-29-33

26-30-34

29-34-38

33-36-40

34-38-43

DIMENSIONS (mm)

Width

900

900

1100

1100

1400

1400

1600

Depth

732

732

732

732

732

732

732

Height

250

250

250

250

250

250

250

26

28

33

33

41

43

47

WEIGHT (kg) ELECTRICAL SUPPLy

Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit

PHASE

Single

Single

Single

Single

Single

Single

Single

FUSE RATING (BS88) - HRC (A)

6

6

6

6

6

6

6

INTERCONNECTING CABLE No. CORES

4

4

4

4

4

4

4

SUZ-KA35VA2

SUZ-KA50VA2

SUZ-KA60VA2

48 / 47

55 / 53

55 / 53

55 / 55

54 / 50 (47)

55 / 51 (48)

56 / 52 (49)

37

53

53

53

75 / 77

99 / 101

99 / 101

Width

800

840

840

840

950

950

950

Depth

285

330

330

330

330 + 30

330 + 30

330 + 30

943

1350

1350

SUZ-KA / PUHZ-P - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)

Heating/Cooling (silent)

WEIGHT (kg) DIMENSIONS (mm)

Height ELECTRICAL SUPPLy PHASE SySTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SySTEM RUNNING CURRENT (A) Single Phase Heating/Cooling

[MAX]

3 Phase

SUZ-KA71VA2 PUHZ-P100VHA3/YHA PUHZ-P125VHA3/YHA PUHZ-P140VHA3/YHA

550

850

850

880

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz

B(Suspension bolt pitch) C

Rear View

>

D

732 700

32

Side View

>

238

Drain pipe Drain pump (O.D. 32)

10

136

67 356

Drain pipe (Spontaneous draining)

220-240v, 50Hz / 380-415v, 50Hz 220-240v, 50Hz / 380-415v, 50Hz 220-240v, 50Hz / 380-415v, 50Hz

Single

Single

Single

Single

Single / 3

Single / 3

Single / 3

1.11 / 1.06

1.62 / 1.52

1.94 / 1.68

2.04 / 2.10

3.10 / 3.04

3.87 / 4.22

4.43 / 4.52

1.01 / 0.85

1.47 / 1.22

1.77 / 1.34

1.86 / 1.68

2.76 / 2.58

3.44 / 3.59

3.94 / 3.84

4.75

6.75

9.75

8.89

8/3

11 / 4

5.82 / 5.62 [10.3]

7.74 / 8.14 [17.4]

11.37 / 9.97 [17.6] 10.92 / 10.82 [18.1] 16.18 / 15.38 [30.7] 19.49 / 20.59 [30.8]

11 / 4 23.23 / 24.38 [32.3]

-

-

-

-

5.12 / 5.03 [15.7]

6.29 / 6.85 [15.8]

7.19 / 7.34 [15.8]

FUSE RATING (BS88) - HRC (A)

16

20

20

20

32 / 16

32 / 16

40 / 16

MAINS CABLE No. Cores

3

3

3

3

3/5

3/5

3/5

MAX PIPE LENGTH (m)

20

30

30

30

50

50

50

MAX HEIGHT DIFFERENCE (m)

12

30

30

30

30

30

30

1.05

1.6

1.8

1.8

3.0

4.5

4.5

CHARGE R410A (kg)

A 23

PEAD-RP Standard Inverter Heat Pump

16.0 (5.0-18.0)

12.3 (5.5-14.0)

250

14.0 (5.0-16.0)

9.4 (4.9-11.2)

217

11.2 (4.5-12.5)

7.1 (0.9-8.1)

122

8.0 (0.9-10.2)

5.7 (1.1-6.3)

33

7.0 (0.9-8.0)

4.9 (1.1-5.6)

23 40

5.9 (0.9-7.2)

3.6 (1.0-3.9)

100

4.1 (0.9-5.0)

Cooling (nominal)

178(Duct)

Heating (nominal)

Air inlet

CAPACITy (kW)

41

MODEL REFERENCE

Model

A

B

C

D

900 954 1000 860 PEAD-RP60-71JAQ 1100 1154 1200 1060 PEAD-RP100-125JAQ 1400 1454 1500 1360 PEAD-RP140JAQ 1600 1654 1700 1560 PEAD-RP35-50JAQ

E 9 11 14 16

F

G

800 858 1000 1058 1300 1358 1500 1558

Notes: All units charged to 7m (35-71), 20m (100) and 30m (125-140) pipe length.

Page 90

Page 91


Ceiling Concealed Ducted System

Dimensions

INDOOR UNIT PEAD-RP71-125JAQ

Zubadan sets a new standard in performance The Mr Slim Zubadan Inverter heat pumps achieve an excellent heating performance even when the outdoor air temperature is as low as -25ºC. I

Stable Heating Performance - Full heating capacity at -15°C, a 30% capacity improvement over the next size up Power Inverter

I

Expanded Heating Operation - Will work effectively even when the outdoor ambient air temperature is -25°C

I

Stable Operation - Utilising the new Flash Injection Circuit the Zubadan models have reduced defrost times and can provide continuous heating for up to 150 mins

40

15

58

57 20

>

Air outlet

Upper View

100

57

Quick Start-Up - At -20ºC, full heating capacity is achieved in about 20 mins, improving comfort levels

D (Duct) 100x(E-1)=F

30 10

I

>

Front View

Mr Slim Range

PEAD-RP Zubadan Inverter Heat Pump

643(Suspension bolt pitch)

Technical Information PEAD-RP - INDOOR UNITS

7.9 (3.45-10.1)

11.1 (4.45-13.85)

13.85 (4.95-15.85)

Cooling (UK)

6.55 (3.05-7.45)

9.2 (4.5-10.5)

11.5 (5.05-12.9)

SHF (nominal & UK)

0.83

0.82

0.84

COP / EER (nominal)

3.42 / 3.30

3.61 / 3.27

3.61 / 3.21

ENERGy LABEL

Heating/Cooling

B /A

A /A

A /A

AIRFLOW (m3/min)

Lo-Mi-Hi

17.5-21-25

24-29-34

29.5-33.5-42

PIPE SIZE mm(in)

Gas

15.88 (5/8”)

15.88 (5/8”)

15.88 (5/8”)

Liquid EXTERNAL STATIC PRESSURE (Pa) Lo-Mi1-Mi2-Mi3-Hi

9.52 (3/8”)

9.52 (3/8”)

9.52 (3/8”)

35-50-70-100-150

35-50-70-100-150

35-50-70-100-150

NOISE (dBA) (50Pa)

Lo-Mi-Hi

26-30-34

29-34-38

33-36-40

DIMENSIONS (mm)

Width

1100

1400

1400

Depth

732

732

732

Height

250

250

250

33

41

43

Fed by Outdoor Unit

Fed by Outdoor Unit

Fed by Outdoor Unit

Single

Single

Single

FUSE RATING (BS88) - HRC (A)

6

6

6

INTERCONNECTING CABLE No. CORES

4

4

4

PUHZ-HRP71VHA2

PUHZ-HRP100VHA2/YHA2

PUHZ-HRP125YHA2

52 / 51 (48)

52 / 51 (48)

52 / 51 (48)

120

120 / 134

134

Width

950

950

950

Depth

330 + 30

330 + 30

330 + 30

Height

1350

1350

1350

220-240v, 50Hz

220-240v, 50Hz / 380-415,50Hz

380-415,50Hz

WEIGHT (kg) ELECTRICAL SUPPLy PHASE

PUHZ-HRP - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)

Heating/Cooling (silent)

WEIGHT (kg) DIMENSIONS (mm)

ELECTRICAL SUPPLy PHASE SySTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SySTEM RUNNING CURRENT (A) Single Phase Heating/Cooling

[MAX]

3 Phase

Single

Single / 3

3

2.34 / 2.15

3.10 / 3.06

3.88 / 3.89

3.39 / 1.83

4.50 / 2.60

5.63 / 3.31

14

14 / 3

3

10.99 / 10.15 [31.5]

14.43 / 14.28 [37.7]

-

-

6.07 / 6.09 [15.7]

7.84 / 7.94 [15.8]

FUSE RATING (BS88) - HRC (A)

32

40 / 16

16

MAINS CABLE No. Cores

3

3/5

5

MAX PIPE LENGTH (m)

75

75

75

MAX HEIGHT DIFFERENCE (m)

30

30

30

CHARGE R410A (kg) - 30m

5.5

5.5

5.5

Page 92

B(Suspension bolt pitch) C

Rear View

>

D

732 700

32

Side View

>

238

Drain pipe Drain pump (O.D. 32)

10

136

Model

67 356

A

Drain pipe (Spontaneous draining)

B

C

D

1100 1154 1200 1060 PEAD-RP100-125JAQ 1400 1454 1500 1360 PEAD-RP71JAQ

PEAD-RP Zubadan Inverter Heat Pump

Heating (UK)

A 23

250

12.5 (5.5-14.0)

41

14.0 (5.0-16.0)

10.0 (4.9-11.4)

217

11.2 (4.5-14.0)

7.1 (3.3-8.1)

122

8.0 (3.5-10.2)

Cooling (nominal)

33

Heating (nominal)

23 40

PEAD-RP125JAQ

100

PEAD-RP100JAQ

Air inlet

CAPACITy (kW)

PEAD-RP71JAQ

178(Duct)

MODEL REFERENCE

E 11 14

F

G

1000 1058 1300 1358

Page 93


Large Capacity Ceiling Concealed Ducted System I

Twin, triple or quadruple configurations on one outdoor unit, utilising Mr Slim indoor units

I

Static pressure of up to 150Pa

Dimensions

INDOOR UNIT PEA-RP200GAQ Front View

>

Upper View

>

Side View

>

Mr Slim Range

PEA-RP-GAQ Power Inverter Heat Pump

INDOOR UNIT PEA-RP250GAQ Front View

PEA-RP-GAQ - INDOOR UNITS MODEL REFERENCE CAPACITy (kW)

Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK)

SHF (nominal & UK) COP / EER (nominal) ENERGy LABEL AIRFLOW (m3/min) PIPE SIZE mm(in)

Heating/Cooling Lo-Hi Gas Liquid EXTERNAL STATIC PRESSURE (Pa) NOISE (dBA) Lo-Hi DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLy PHASE POWER INPUT (kW) (nominal) (UK) STARTING CURRENT (A) RUNNING CURRENT (A) [Max] FUSE RATING (BS88) – HRC (A) MAINS CABLE No. Cores INTERCONNECTING CABLE No. CORES

PEA-RP200GAQ 22.4 (9.5-25.0) 19.0 (9.0-22.4) 19.05 (8.1-21.25) 17.5 (8.3-20.6) 0.81 3.45 / 2.84 B / C 52-65 28.58 (1 1/8”) 9.52 (3/8”) 150 48-51 1400 634 400 70 380-415v, 50Hz 3 1.00 0.89 5.6 2.0 [2.4]

PEA-RP250GAQ 27.0 (12.5-31.5) 22.0 (11.2-28.0) 22.95 (10.65-26.8) 20.25 (10.3-25.75) 0.86 3.29 / 2.64 C / D 64-80 28.58 (1 1/8”) 12.7 (1/2”) 150 49-52 1600 634 400 77 380-415v, 50Hz 3 1.18 1.05 5.6 2.3 [2.8]

PEA-RP400GAQ 44.8 (18.0-50.0) 38.0 (18.0-44.8) 38.1 (15.3-42.5) 34.95 (16.55-41.2) 0.75 3.57 / 2.93 B / C 120 28.58 (1 1/8”) x2 9.52 (3/8”) x2 150 52 1947 764 595 130 380-415v, 50Hz 3 1.55 1.38 8.7 3.8 [4.6]

PEA-RP500GAQ 54.0 (25.0-63.0) 44.0 (22.4-56.0) 45.9 (21.25-53.55) 40.5 (20.6-51.5) 0.77 3.20 / 2.56 D / E 160 28.58 (1 1/8”) x2 12.7 (1/2”) x2 150 53 1947 764 595 133 380-415v, 50Hz 3 2.84 2.53 10 5.4 [6.5]

6 5 3

6 5 3

10 5 3

10 5 3

PUHZ-RP200YKA 59 / 58 (55) 135 1050 330 + 30 1338 380-415v, 50Hz 3 6.5 / 6.7 5.79 / 5.7 5 8.63 / 8.94 [19]

PUHZ-RP250YKA 59 / 58 (55) 141 1050 330 + 30 1338 380-415v, 50Hz 3 8.2 / 8.34 7.3 / 7.09 5 11.01 / 11.23 [21]

PUHZ-RP200YKA x2 59 / 58 (55) 135 1050 330 + 30 1338 380-415v, 50Hz 3 12.55 / 12.95 11.17 / 11.01 5 8.63 / 8.94 [19]

PUHZ-RP250YKA x2 59 / 58 (55) 141 1050 330 + 30 1338 380-415v, 50Hz 3 16.88 / 17.16 15.02 / 14.59 5 11.01 / 11.23 [21]

20 5 120 30 7.1

25 5 120 30 7.7

20 5 120 30 7.1

25 5 120 30 7.7

>

Upper View

>

Side View

>

Side View

>

PEA-RP-GAQ Power Inverter Heat Pump

Technical Information

INDOOR UNIT PEA-RP400-500GAQ Front View

>

PUHZ-RP-YKA - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm)

Heating/Cooling (silent) Width Depth Height

ELECTRICAL SUPPLy PHASE SySTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) RUNNING CURRENT (A) [Max] Heating/Cooling FUSE RATING (BS88) – HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 30m

Page 94

Upper View

>

Page 95


Large Capacity Ceiling Concealed Ducted System

INDOOR UNIT PEA-RP200GAQ

The Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the Power Inverter range. I

Twin, triple or quadruple configurations on one outdoor unit, utilising Mr Slim indoor units

I

Static pressure of up to 150Pa

Dimensions

Front View

>

Side View Upper View

>

>

Mr Slim Range

PEA-RP-GAQ Standard Inverter Heat Pump

INDOOR UNIT PEA-RP250GAQ Front View

PEA-RP-GAQ - INDOOR UNITS MODEL REFERENCE CAPACITy (kW)

Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK)

SHF (nominal & UK) COP / EER (nominal) ENERGy LABEL AIRFLOW (m3/min) PIPE SIZE mm(in)

Heating/Cooling Lo-Hi Gas Liquid EXTERNAL STATIC PRESSURE (Pa) NOISE (dBA) Lo-Hi DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLy PHASE POWER INPUT (kW) (nominal) (UK) STARTING CURRENT (A) RUNNING CURRENT (A) [Max] FUSE RATING (BS88) – HRC (A) MAINS CABLE No. Cores INTERCONNECTING CABLE No. CORES

PEA-RP200GAQ 22.4 (9.5-25.0) 19.0 (9.0-22.4) 19.05 (8.1-21.25) 17.5 (8.3-20.6) 0.81 3.04 / 2.64

PEA-RP250GAQ 27.0 (12.5-31.5) 22.0 (11.2-28.0) 22.95 (10.65-26.8) 20.25 (10.3-25.75) 0.86 3.19 / 2.61

PEA-RP400GAQ 44.8 (19.0-50.0) 38.0 (18.0-44.8) 38.1 (16.15-42.5) 34.95 (16.55-41.2) 0.75 3.14 / 2.72

PEA-RP500GAQ 54.0 (25.0-63.0) 44.0 (22.4-56.0) 45.9 (21.25-53.55) 40.5 (20.6-51.5) 0.77 3.10 / 2.53

D / D 52-65 28.58 (1 1/8”) 9.52 (3/8”) 150 48-51 1400 634 400 70 380-415v, 50Hz 3 1.00 0.89 5.6 2.0 [2.4] 6 5 3

D / D 64-80 28.58 (1 1/8”) 12.7 (1/2”) 150 49-52 1600 634 400 77 380-415v, 50Hz 3 1.18 1.05 5.6 2.3 [2.8] 6 5 3

D / D 120 28.58 (1 1/8”) x2 9.52 (3/8”) x2 150 52 1947 764 595 130 380-415v, 50Hz 3 1.55 1.38 8.7 3.8 [4.6] 10 5 3

D / E 160 28.58 (1 1/8”) x2 12.7 (1/2”) x2 150 53 1947 764 595 133 380-415v, 50Hz 3 2.84 2.53 10 5.4 [ 6.5] 10 5 3

PUHZ-P200YHA3 59 / 59 (56) 126 950 330+30 1350 380-415v, 50Hz 3 7.36 / 7.21 6.55 / 6.13 5 9.88 / 9.47 [ 19 ]

PUHZ-P250YHA3 59 / 59 (56) 135 950 330+30 1350 380-415v, 50Hz 3 8.47 / 8.44 7.54 / 7.17 5 12.0 / 11.0 [ 21 ]

PUHZ-P200YHA3 x2 59 / 59 (56) 126 950 330+30 1350 380-415v, 50Hz 3

PUHZ-P250YHA3 x2 59 / 59 (56) 135 950 330+30 1350 380-415v, 50Hz 3 17.42 / 17.36 15.5 / 14.76 5 12.0 / 11.0 [ 21 ]

20 5 70 30 5.8

25 5 70 30 7.1

>

Upper View

Side View

>

Side View

>

>

PEA-RP-GAQ Standard Inverter Heat Pump

Technical Information

INDOOR UNIT PEA-RP400-500GAQ Front View

>

PUHZ-P-YHA3 - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm)

Heating/Cooling (silent) Width Depth Height

ELECTRICAL SUPPLy PHASE SySTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) RUNNING CURRENT (A) [Max] Heating/Cooling FUSE RATING (BS88) – HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 30m

Page 96

14.27 / 13.97 12.7 / 11.88 5 9.88 / 9.47 [ 19 ] 20 5 70 per outdoor 30 5.8

Upper View

>

25 5 70 per outdoor 30 7.1

Page 97


Dimensions INDOOR UNIT SLZ-KA25-50VAQ

600x600 4-Way Blow Ceiling Cassette System The SLZ-KA-VAQ series is perfect for both residential and small business applications, as it offers inverter technology alongside quiet operation. The compact size of this unit is ideal for 600 by 600mm ceilings and with a depth of 208mm, this lightweight unit makes installation a breeze. This unit also comes complete with a long life filter that will last for approximately 2,500 hours.

Lower View

Note: Optional interfaces for M-NET connectivity (MAC-399IF) and group control, fault/run (MAC-397IF) are available. Please see accessories / optional extras section.

>

Mr Slim Range

SLZ-KA-VAQ Inverter Heat Pump

Technical Information

SLZ-KA-VAQ - INDOOR UNITS CAPACITy (kW)

SLZ-KA25VAQ

SLZ-KA35VAQ

SLZ-KA50VAQ

Heating (nominal)

3.2 (0.9-4.5)

4.0 (0.9-5.0)

5.0 (0.9-6.5)

Cooling (nominal)

2.5 (0.9-3.2)

3.5 (1.0-3.9)

4.6 (1.1-5.2)

Heating (UK)

2.65 (0.75-3.75)

3.3 (0.75-4.15)

4.15 (0.75-5.4)

Cooling (UK)

4.55 (1.1-5.15)

2.5 (0.9-3.15)

3.45 (1.0-3.85)

SHF (nominal & UK)

0.86

0.77

0.68

COP / EER (nominal)

3.76 / 3.68

3.67 / 3.37

3.23 / 3.01

ENERGy LABEL

Heating/Cooling

A /A

A /A

C/B

AIRFLOW (m3/min)

Lo-Mi-Hi

8-9-10

8-9-11

8-9-11

Gas

9.52 (3/8”)

9.52 (3/8”)

12.7 (1/2”)

Liquid

6.35 (1/4”)

6.35 (1/4”)

6.35 (1/4”)

28-31-37

29-33-38

30-34-39

DIMENSIONS (mm) (grille) Width

570 (650)

570 (650)

570 (650)

Depth

570 (650)

570 (650)

570 (650)

Height

235 (20)

235 (20)

235 (20)

17

17

17

PIPE SIZE mm(in)

NOISE (dBA)

WEIGHT (kg)

Lo-Mi-Hi

Unit Grille

ELECTRICAL SUPPLy

3

3

3

Fed by Outdoor Unit

Fed by Outdoor Unit

Fed by Outdoor Unit

Single

Single

Single

FUSE RATING (BS88) - HRC (A)

6

6

6

INTERCONNECTING CABLE No. CORES

4

4

4

SLP-2AAW

SLP-2AAW

SLP-2AAW

SUZ-KA25VA2

SUZ-KA35VA2

SUZ-KA50VA2

46 / 46

48 / 47

55 / 53

33

37

53

Width

800

800

840

Depth

285

285

330

Height

550

550

850

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz

PHASE

GRILLE REFERENCE

Side View

>

SLZ-KA-VAQ Inverter Heat Pump

MODEL REFERENCE

SUZ-KA-VA2 - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)

Heating/Cooling

WEIGHT (kg) DIMENSIONS (mm)

ELECTRICAL SUPPLy

Single

Single

Single

0.85 / 0.68

1.09 / 1.04

1.55 / 1.53

0.77 / 0.54

0.99 / 0.83

1.41 / 1.22

3.65

4.75

6.75

4.05 / 3.45 [8.5]

5.15 / 4.95 [9.6]

7.05 / 7.45 [16.7]

FUSE RATING (BS88) - HRC (A)

10

10

20

MAINS CABLE No. CORES

3

3

3

MAX PIPE LENGTH (m)

20

20

30

PHASE SySTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SySTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

MAX HEIGHT DIFFERENCE (m)

12

12

30

CHARGE R410A (kg) - 7m

0.8

1.05

1.6

Page 98

Page 99


Dimensions

4-Way Blow Ceiling Cassette System I

Airflow controllable for ceiling heights up to 4.2m, with automatic adjustment of fan speed

I

Reduced draft air distribution, with independent vane control

I

Filter lowering operation down to 4m (optional PLP-6BAJ grille required)

I

Optional ‘I See Sensor' for energy saving and smooth temperature control throughout the room

INDOOR UNIT PLA-RP35-140BA(2)(3) Upper View

>

Lower View

>

Mr Slim Range

PLA-RP Power Inverter Heat Pump

Technical Information PLA-RP - INDOOR UNITS CAPACITy (kW)

PLA-RP35BA

PLA-RP50BA

PLA-RP60BA

PLA-RP71BA2

Heating (nominal)

4.1 (1.6-5.2)

6.0 (2.5-7.3)

7.0 (2.8-8.2)

8.0 (3.5-10.2)

PLA-RP100BA3 PLA-RP125BA2 11.2 (4.5-14.0)

14.0 (5.0-16.0)

16.0 (5.7-18.0)

Cooling (nominal)

3.6 (1.6-4.5)

5.0 (2.3-5.6)

6.0 (2.7-6.7)

7.1 (3.3-8.1)

10.0 (4.9-11.4)

12.5 (5.5-14.0)

14.0 (6.2-15.3)

Heating (UK)

3.5 (1.35-4.4)

5.1 (2.15-6.2)

5.95 (2.4-6.95)

6.8 (3.0-8.65)

9.5 (3.85-11.9)

11.9 (4.25-13.6)

13.6 (4.85-15.3)

Cooling (UK)

12.9 (5.7-14.1)

PLA-RP140BA2

3.3 (1.45-4.15)

4.6 (2.1-5.15)

5.5 (2.5-6.15)

6.55 (3.05-7.45)

9.2 (4.5-10.5)

11.5 (5.05-12.9)

SHF (nominal & UK)

0.84

0.81

0.76

0.73

0.74

0.71

0.71

COP / EER (nominal)

3.66 / 3.36

3.61 / 3.23

3.85 / 3.75

4.21 / 3.74

4.61 / 4.18

4.00 / 3.41

3.70 / 3.21

ENERGy LABEL

Heating/Cooling

A /A

A /A

A /A

A /A

A /A

A /A

A /A

AIRFLOW (m3/min)

Lo-Mi1-Mi2-Hi

11-12-13-15

12-14-16-18

12-14-16-18

14-16-18-21

20-23-26-30

22-25-28-31

24-26-29-32 15.88 (5/8”)

Gas

12.7 (1/2”)

12.7 (1/2”)

15.88 (5/8”)

15.88 (5/8”)

15.88 (5/8”)

15.88 (5/8”)

Liquid

6.35 (1/4”)

6.35 (1/4”)

9.52 (3/8”)

9.52 (3/8”)

9.52 (3/8”)

9.52 (3/8”)

9.52 (3/8”)

NOISE (dBA)

Lo-Mi1-Mi2-Hi

27-28-29-31

28-29-31-32

28-29-31-32

28-30-32-34

32-34-37-40

34-36-39-41

36-39-42-44

DIMENSIONS (mm)

Width

840 (950)

840 (950)

840 (950)

840 (950)

840 (950)

840 (950)

840 (950)

(Grille)

Depth

840 (950)

840 (950)

840 (950)

840 (950)

840 (950)

840 (950)

840 (950)

Height

258 (35)

258 (35)

258 (35)

258 (35)

298 (35)

298 (35)

298 (35)

Unit

22

22

23

23

26

27

27

Panel

6

6

6

6

6

6

PIPE SIZE mm(in)

WEIGHT (kg)

Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit

ELECTRICAL SUPPLy

6 Fed by Outdoor Unit

Single

Single

Single

Single

Single

Single

Single

FUSE RATING (BS88) - HRC (A)

6

6

6

6

6

6

6

INTERCONNECTING CABLE No. CORES

4

4

4

4

4

4

4

PLP-6BA

PLP-6BA

PLP-6BA

PLP-6BA

PLP-6BA

PLP-6BA

PLP-6BA

PAR-21MAA

PAR-21MAA

PAR-21MAA

PAR-21MAA

PAR-21MAA

PAR-21MAA

PAR-21MAA

PHASE

GRILLE REFERENCE WIRED REMOTE CONTROLLER REFERENCE

Side View

PUHZ-RP - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)

PUHZ-RP35VHA4

PUHZ-RP50VHA4

46 / 44 (41)

46 / 44 (41)

48 / 47 (44)

48 / 47 (44)

51 / 49 (46)

52 / 50 (47)

52 / 50 (47)

42

42

67

67

116 / 124

116 / 126

118 / 132

Width

800

800

950

950

1050

1050

1050

Depth

300 + 23

300 + 23

330 + 30

330 + 30

330 + 30

330 + 30

330 + 30

1338

1338

1338

Heating/Cooling (silent)

WEIGHT (kg) DIMENSIONS (mm)

Height ELECTRICAL SUPPLy PHASE SySTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SySTEM RUNNING CURRENT (A) Single Phase Heating/Cooling

[MAX]

3 Phase

FUSE RATING (BS88) - HRC (A)

>

PUHZ-RP60VHA4 PUHZ-RP71VHA4 PUHZ-RP100VKA/YKA PUHZ-RP125VKA/YKA PUHZ-RP140VKA/YKA

600

600

943

943

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz /380-415v,50Hz 220-240v, 50Hz/380-415v,50Hz 220-240v, 50Hz / 380-415v,50Hz

Single

Single

Single

Single

Single / 3

Single / 3

Single / 3

1.12 / 1.07

1.66 / 1.55

1.82 / 1.60

1.90 / 1.90

2.43 / 2.39

3.50 / 3.67

4.32 / 4.36

1.00 / 0.91

1.48 / 1.32

1.62 / 1.36

1.69 / 1.62

2.16 / 2.03

3.12 / 3.12

3.84 / 3.71

5

5

5

5

5

5

5.15 / 4.98 [13.2]

7.62 / 7.08 [13.4]

8.34 / 7.31 [19.4]

5

8.76 / 8.71 [19.5] 11.26 / 11.04 [27.5] 16.02 / 16.73 [27.5]

19.76 / 19.90 [29.1]

-

-

-

-

4.59 / 4.51 [9]

6.26 / 6.51 [10.5]

7.61 / 7.66 [12.1]

16

16

20

20

32 / 10

32 / 16

32 / 16

MAINS CABLE No. Cores

3

3

3

3

3/5

3/5

3/5

MAX PIPE LENGTH (m)

50

50

50

50

75

75

75

MAX HEIGHT DIFFERENCE (m)

30

30

30

30

30

30

30

CHARGE R410A (kg) - 30m

2.5

2.5

3.5

3.5

5.0

5.0

5.0

Page 100

PLA-RP Power Inverter Heat Pump

MODEL REFERENCE

Models

A

B

Size 35-71

241

258

Size 100-140

281

298

Page 101


Dimensions

4-Way Blow Ceiling Cassette System

INDOOR UNIT PLA-RP35-140BA(2)

The new Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the Power Inverter range. I

Airflow controllable for ceiling heights up to 4.2m, with automatic adjustment of fan speed

I

Reduced draft air distribution, with independent vane control

I

Filter lowering operation down to 4m (optional PLP-6BAJ grille required)

I

Optional ‘I See Sensor’ for energy saving and smooth temperature control throughout the room

I

3-phase Standard Inverters now available

Upper View

>

Lower View

>

Mr Slim Range

PLA-RP Standard Inverter Heat Pump

Technical Information PLA-RP - INDOOR UNITS MODEL REFERENCE

PLA-RP35BA

PLA-RP50BA

PLA-RP60BA

PLA-RP71BA

PLA-RP100BA

PLA-RP125BA

PLA-RP140BA2

Heating (nominal)

4.1 (0.9-5.0)

6.0 (0.9-7.2)

6.9 (0.9-8.0)

8.0 (0.9-10.2)

11.2 (4.5-12.5)

14.0 (5.0-16.0)

16.0 (5.0-18.0)

Cooling (nominal)

3.6 (1.0-3.9)

5.5 (1.1-5.6)

6.1 (1.1-6.3)

7.1 (0.9-8.1)

9.4 (4.9-11.2)

12.3 (5.5-14.0)

13.6 (5.5-15.0)

Heating (UK)

3.4 (0.75-4.15)

5.0 (0.75-6.0)

5.75 (0.75-6.65)

6.65 (0.75-8.5)

9.5 (3.85-10.65)

11.9 (4.25-13.6)

13.6 (4.25-15.3)

Cooling (UK)

3.55 (1.0-3.85)

5.45 (1.1-5.55)

6.05 (1.1-6.25)

7.05 (0.9-8.05)

8.65 (4.5-10.3)

11.3 (5.05-12.9)

12.5 (5.05-13.8)

SHF (nominal & UK)

0.84

0.81

0.76

0.73

0.74

0.71

0.71

COP / EER (nominal)

3.94 / 3.30

3.66 / 3.22

3.50 / 3.26

3.65 / 3.43

3.41 / 3.01

3.41 / 3.01

3.21 / 2.61

ENERGy LABEL

Heating/Cooling

A /A

A /A

B /A

A /A

B/B

B/B

C/D

AIRFLOW (m3/min)

Lo-Mi1-Mi2-Hi

11-12-13-15

12-14-16-18

12-14-16-18

14-16-18-21

20-23-26-30

22-25-28-31

24-26-29-32 15.88 (5/8”)

Gas

9.52 (3/8”)

12.7 (1/2”)

15.88 (5/8”)

15.88 (5/8”)

15.88 (5/8”)

15.88 (5/8”)

Liquid

6.35 (1/4”)

6.35 (1/4”)

6.35 (1/4”)

9.52 (3/8”)

9.52 (3/8”)

9.52 (3/8”)

9.52 (3/8”)

NOISE (dBA)

Lo-Mi1-Mi2-Hi

27-28-29-31

28-29-31-32

28-29-31-32

28-30-32-34

32-34-37-40

34-36-39-41

36-39-42-44

DIMENSIONS (mm)

Width

840 (950)

840 (950)

840 (950)

840 (950)

840 (950)

840 (950)

840 (950)

(Grille)

Depth

840 (950)

840 (950)

840 (950)

840 (950)

840 (950)

840 (950)

840 (950)

Height

258 (35)

258 (35)

258 (35)

258 (35)

298 (35)

298 (35)

298 (35)

Unit

22

22

23

23

25

25

27

Panel

6

6

6

6

6

6

6

PIPE SIZE mm(in)

WEIGHT (kg)

Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit

ELECTRICAL SUPPLy

Single

Single

Single

Single

Single

Single

Single

FUSE RATING (BS88) - HRC (A)

6

6

6

6

6

6

6

INTERCONNECTING CABLE No. CORES

4

4

4

4

4

4

4

PLP-6BA

PLP-6BA

PLP-6BA

PLP-6BA

PLP-6BA

PLP-6BA

PLP-6BA

PAR-21MAA

PAR-21MAA

PAR-21MAA

PAR-21MAA

PAR-21MAA

PAR-21MAA

PAR-21MAA

PHASE

GRILLE REFERENCE WIRED REMOTE CONTROLLER REFERENCE

Side View

SUZ-KA / PUHZ-P - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)

SUZ-KA35VA2

SUZ-KA50VA2

SUZ-KA60VA2

48 / 47

55 / 53

55 / 53

55 / 55

54 / 50 (47)

55 / 51 (48)

56 / 52 (49)

37

53

53

53

75 / 77

99 / 101

99 / 101

Width

800

840

840

840

950

950

950

Depth

285

330

330

330

330 + 30

330 + 30

330 + 30

943

1350

1350

Heating/Cooling (silent)

WEIGHT (kg) DIMENSIONS (mm)

Height ELECTRICAL SUPPLy PHASE SySTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SySTEM RUNNING CURRENT (A) Single Phase Heating/Cooling

[MAX]

3 Phase

FUSE RATING (BS88) - HRC (A)

550

850

850

880

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz /380-415v,50Hz 220-240v, 50Hz /380-415v,50Hz 220-240v, 50Hz /380-415v,50Hz

Single

Single

Single

Single

Single / 3

Single / 3

Single / 3

1.04 / 1.09

1.64 / 1.71

1.97 / 1.87

2.19 / 2.07

3.28 / 3.12

4.11 / 4.09

4.98 / 5.21

0.95 / 0.87

1.49 / 1.37

1.79 / 1.50

1.99 / 1.66

2.92 / 2.65

3.66 / 3.48

4.43 / 4.43

4.75

6.75

9.75

8.89

8/3

11 / 4

4.97 / 4.77 [9.4]

6.71 / 7.11 [16.4]

10.11 / 8.71 [16.4]

11 / 4

9.46 / 9.36 [16.6] 14.92 / 14.16 [28.9] 18.23 / 18.48 [29]

22.50 / 23.71 [30.6]

-

-

-

-

5.34 / 5.09 [13.9]

6.54 / 6.51 [14]

7.91 / 8.28 [14.1]

10

20

20

20

32 / 16

32 / 16

32 / 16

3

3

3

3

3/5

3/5

3/5

MAX PIPE LENGTH (m)

20

30

30

30

50

50

50

CHARGE R410A (kg)

>

SUZ-KA71VA2 PUHZ-P100VHA3/YHA PUHZ-P125VHA3/YHA PUHZ-P140VHA3/YHA

MAINS CABLE No. Cores MAX HEIGHT DIFFERENCE (m)

PLA-RP Standard Inverter Heat Pump

CAPACITy (kW)

12

30

30

30

30

30

30

1.05

1.6

1.8

1.8

3.0

4.5

4.5

Models

A

B

Size 35-71

241

258

Size 100-140

281

298

Notes: All units charged to 7m (35-71), 20m (100) and 30m (125-140) pipe length.

Page 102

Page 103


4-Way Blow Ceiling Cassette System

Dimensions

INDOOR UNIT PLA-RP71-125BA(2)(3)

Zubadan sets a new standard in performance The Mr Slim Zubadan Inverter heat pumps achieve an excellent heating performance even when the outdoor air temperature is as low as -25ºC. I

Stable Heating Performance - Full heating capacity at -15°C, a 30% capacity improvement over the next size up Power Inverter

I

Expanded Heating Operation - Will work effectively even when the outdoor ambient air temperature is -25°C

I

Stable Operation - Utilising the new Flash Injection Circuit the Zubadan models have reduced defrost times and can provide continuous heating for up to 150 mins

I

Quick Start-Up - At -20ºC, full heating capacity is achieved in about 20 mins, improving comfort levels

Upper View

>

Lower View

>

Mr Slim Range

PLA-RP Zubadan Inver ter Heat Pump

Technical Information MODEL REFERENCE CAPACITy (kW)

PLA-RP71BA2

PLA-RP100BA3

PLA-RP125BA2

Heating (nominal)

8.0 (4.5-10.2)

11.2 (4.5-14.0)

14.0 (5.0-16.0)

Cooling (nominal)

7.1 (4.9-8.1)

10.0 (4.9-11.4)

12.5 (5.5-14.0)

Heating (UK)

7.9 (4.45-10.1)

11.1 (4.45-13.85)

13.85 (4.95-15.85)

Cooling (UK)

6.55 (4.5-7.45)

9.2 (4.5-10.5)

11.5 (5.05-12.9)

0.73

0.74

0.71

4.21 / 3.66

4.41 / 4.10 [4.31 / 4.00]

3.92 / 3.30

SHF (nominal & UK) COP / EER (nominal)

[3 Phase]

ENERGy LABEL

Heating/Cooling

A /A

A /A

A /A

AIRFLOW (m3/min)

Lo-Mi1-Mi2-Hi

14-16-18-21

20-23-26-30

22-25-28-31 15.88 (5/8”)

Gas

15.88 (5/8”)

15.88 (5/8”)

Liquid

9.52 (3/8”)

9.52 (3/8”)

9.52 (3/8”)

NOISE (dBA)

Lo-Mi1-Mi2-Hi

28-30-32-34

32-34-37-40

34-36-39-41

DIMENSIONS (mm)

Width

840 (950)

840 (950)

840 (950)

(Grille)

Depth

840 (950)

840 (950)

840 (950)

Height

258 (35)

298 (35)

298 (35)

Unit

23

26

27

Panel

6

6

6

Fed by Outdoor Unit

Fed by Outdoor Unit

Fed by Outdoor Unit

PIPE SIZE mm(in)

WEIGHT (kg) ELECTRICAL SUPPLy

Single

Single

Single

FUSE RATING (BS88) - HRC (A)

6

6

6

INTERCONNECTING CABLE No. CORES

4

4

4

PLP-6BA

PLP-6BA

PLP-6BA

PAR-21MAA

PAR-21MAA

PAR-21MAA

PHASE

GRILLE REFERENCE WIRED REMOTE CONTROLLER REFERENCE

Side View

PUHZ-HRP - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)

PUHZ-HRP71VHA2

PUHZ-HRP100VHA2/YHA2

PUHZ-HRP125YHA2

52 / 51 (48)

52 / 51 (48)

52 / 51 (48)

120

120 / 134

134

Width

950

950

950

Depth

330 + 30

330 + 30

330 + 30

Heating/Cooling (silent)

WEIGHT (kg) DIMENSIONS (mm)

Height ELECTRICAL SUPPLy PHASE

1350

1350

1350

220-240v, 50Hz

220-240v, 50Hz / 380-415,50Hz

380-415,50Hz

Single

Single / 3

3

SySTEM POWER INPUT (kW) Heating/Cooling (nominal)

1.90 / 1.94

2.54 / 2.44 [2.60 / 2.50]

3.57 / 3.79

[3 Phase]

2.76 / 1.65

3.68 / 2.07 [3.77 / 2.13]

5.18 / 3.22

14

14 / 3

3

8.76 / 8.89 [30]

11.76 / 11.26 [36]

-

Heating/Cooling (UK)

STARTING CURRENT (A) SySTEM RUNNING CURRENT (A) Single Phase Heating/Cooling

[MAX]

3 Phase

-

4.86 / 4.69 [14]

6.37 / 6.70 [14]

32

40 / 16

16

MAINS CABLE No. Cores

3

3/5

5

MAX PIPE LENGTH (m)

75

75

75

FUSE RATING (BS88) - HRC (A)

MAX HEIGHT DIFFERENCE (m)

30

30

30

CHARGE R410A (kg) - 30m

5.5

5.5

5.5

Page 104

PLA-RP Zubadan Inverter Heat Pump

PLA-RP - INDOOR UNITS

>

Models

A

B

Size 71

241

258

Size 100-125

281

298

Page 105


Dimensions

Ceiling Suspended System

PCA-RP50KAQ 51 853

Side View

5

>

254

476

680

57

Lower View

>

236

Flush to wall installation for concealment of service connections

>

10

230

I

Front View

2

195

Indoor unit designed for direct ceiling suspension

960

84 88

I

2

Mr Slim Range

PCA-RP Power Inverter Heat Pump

182

85

878

Technical Information

PCA-RP60-71KAQ 51

5.5 (2.5-6.6)

7.0 (2.8-8.2)

8.0 (3.5-10.2)

11.2 (4.5-14.0)

14.0 (5.0-16.0)

16.0 (5.7-18.0)

Cooling (nominal)

5.0 (2.3-5.6)

6.0 (2.7-6.7)

7.1 (3.3-8.1)

10.0 (4.9-11.4)

12.5 (5.5-14.0)

14.0 (6.2-15.3)

Heating (UK)

4.7 (2.15-5.6)

5.95 (2.4-6.95)

6.8 (3.0-8.65)

9.5 (3.85-11.9)

11.9 (4.25-13.6)

13.6 (4.85-15.3)

Cooling (UK)

12.9 (5.7-14.1)

4.6 (2.1-5.15)

5.5 (2.5-6.15)

6.55 (3.05-7.45)

9.2 (4.5-10.5)

11.5 (5.05-12.9)

SHF (nominal & UK)

0.79

0.81

0.76

0.77

0.72

0.71

COP / EER (nominal)

3.62 / 3.21

3.61 / 4.00

3.62 / 3.62

3.71 / 3.80

3.61 / 3.22

3.61 / 3.21

ENERGy LABEL

Heating/Cooling

A /A

A /A

A /A

A /A

A /A

A /A

AIRFLOW (m3/min)

Lo-Mi1-Mi2-Hi

10-11-13-15

15-16-17-19

16-17-18-20

22-24-26-28

23-25-27-29

24-26-29-32 15.88 (5/8”)

15.88 (5/8”)

15.88 (5/8”)

15.88 (5/8”)

15.88 (5/8”)

6.35 (1/4”)

9.52 (3/8”)

9.52 (3/8”)

9.52 (3/8”)

9.52 (3/8”)

9.52 (3/8”)

Lo-Mi1-Mi2-Hi

32-34-37-40

33-35-37-40

35-37-39-41

37-39-41-43

39-41-43-45

41-43-45-48

Width

960

1280

1280

1600

1600

1600

Depth

680

680

680

680

680

680

Height

230

230

230

230

230

230

32

32

36

38

39

Fed by Outdoor Unit

Fed by Outdoor Unit

Fed by Outdoor Unit

Fed by Outdoor Unit

Fed by Outdoor Unit

Single

Single

Single

Single

Single

Single

FUSE RATING (BS88) - HRC (A)

6

6

6

6

6

6

INTERCONNECTING CABLE No. CORES

4

4

4

4

4

4

NOISE (dBA)

Heating/Cooling (silent)

WEIGHT (kg) DIMENSIONS (mm)

PUHZ-RP60VHA4

PUHZ-RP71VHA4

PUHZ-RP100VKA/YKA

PUHZ-RP125VKA/YKA

PUHZ-RP140VKA/YKA

46 / 44 (41)

48 / 47 (44)

48 / 47 (44)

51 / 49 (46)

52 / 50 (47)

52 / 50 (47) 118 / 132

42

67

67

116 / 124

116 / 126

800

950

950

1050

1050

1050

Depth

300 + 23

330 + 30

330 + 30

330 + 30

330 + 30

330 + 30

1338

1338

1338

Height PHASE SySTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SySTEM RUNNING CURRENT (A) Single Phase Heating/Cooling

PUHZ-RP50VHA4

Width

ELECTRICAL SUPPLy

[MAX]

3 Phase

FUSE RATING (BS88) - HRC (A)

600

943

943

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz / 380-415v,50Hz 220-240v, 50Hz / 380-415v,50Hz 220-240v, 50Hz / 380-415v,50Hz

Single

Single

Single

Single / 3

Single / 3

Single / 3

1.52 / 1.56

1.94 / 1.50

2.21 / 1.96

3.02 / 2.63

3.88 / 3.88

4.43 / 4.36

1.35 / 1.33

1.73 / 1.28

1.97 / 1.67

2.69 / 2.24

3.45 / 3.30

3.94 / 3.71

5

5

5

5

5

5

6.96 / 7.14 [13.4]

8.82 / 6.84 [19.4]

10.06 / 8.94 [19.4]

13.78 / 12.04 [27.2]

17.66 / 17.66 [27.3]

20.13 / 19.82 [28.9]

-

-

-

5.25 / 4.63 [8.7]

6.67 / 6.67 [10.3]

7.63 / 7.52 [11.9]

16

20

20

32 / 10

32 / 16

32 / 16

MAINS CABLE No. Cores

3

3

3

3/5

3/5

3/5

MAX PIPE LENGTH (m)

50

50

50

75

75

75

MAX HEIGHT DIFFERENCE (m)

30

30

30

30

30

30

CHARGE R410A (kg) - 30m

2.5

3.5

3.5

5.0

5.0

5.0

Page 106

Side View

>

85

PCA-RP100-140KAQ 51

PUHZ-RP - OUTDOOR UNITS MODEL REFERENCE

182 1198

Front View

>

2

1600 1493

2

Lower View

10 5

236

PHASE

25 Fed by Outdoor Unit

5

> 680

ELECTRICAL SUPPLy

>

>

84 88 195 230

WEIGHT (kg)

Lower View

Side View

57

DIMENSIONS (mm)

12.7 (1/2”)

5

476

NOISE (dBA)

Gas Liquid

1173

254

PIPE SIZE mm(in)

>

182

85

1518

Page 107

PCA-RP Power Inverter Heat Pump

Heating (nominal)

Front View

236

PCA-RP140KAQ

230

PCA-RP125KAQ

680

PCA-RP100KAQ

195

PCA-RP71KAQ

10

57

PCA-RP60KAQ

1

476

CAPACITy (kW)

PCA-RP50KAQ

2

84 88

MODEL REFERENCE

1280

2

254

PCA-RP - INDOOR UNITS


Ceiling Suspended System

Dimensions

PCA-RP50KAQ 51

Indoor unit designed for direct ceiling suspension

I

Flush to wall installation for concealment of service connections

I

3-phase Standard Inverters now available

2

853

>

5

236

Side View

>

254

476

680

57

Lower View

10

230

>

960

84 88

I

Front View

2

195

The new Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the Power Inverter range.

Mr Slim Range

PCA-RP Standard Inverter Heat Pump

182

85

878

PCA-RP60-71KAQ Technical Information

6.9 (0.9-8.0)

7.9 (0.9-10.2)

11.2 (4.5-12.5)

14.0 (5.0-16.0)

16.0 (5.0-18.0)

5.0 (1.1-5.6)

5.7 (1.1-6.3)

7.1 (0.9-8.1)

9.4 (4.9-11.2)

12.3 (5.5-14.0)

13.6 (5.5-15.0)

Heating (UK)

4.55 (0.75-5.5)

5.75 (0.75-6.65)

6.55 (0.75-8.5)

9.5 (3.85-10.65)

11.9 (4.25-13.6)

13.6 (4.25-15.3)

Cooling (UK)

4.95 (1.1-5.55)

5.65 (1.1-6.25)

7.05 (0.9-8.05)

8.65 (4.5-10.3)

11.3 (5.05-12.9)

12.5 (5.05-13.8)

0.79

0.81

0.76

0.77

0.72

0.71

3.22 / 3.01

3.42 / 3.22

4.03 / 3.45

3.41 / 3.00

3.40 / 3.01

3.41 / 2.81

C/B

B /A

A /A

B/C

C/B

B/C

SHF (nominal & UK) COP / EER (nominal) ENERGy LABEL

Heating/Cooling

AIRFLOW (m3/min)

Lo-Mi1-Mi2-Hi

10-11-13-15

15-16-17-19

16-17-18-20

22-24-26-28

23-25-27-29

24-26-29-32 15.88 (5/8”)

PIPE SIZE mm(in) NOISE (dBA) DIMENSIONS (mm)

Gas

12.7 (1/2”)

15.88 (5/8”)

15.88 (5/8”)

15.88 (5/8”)

15.88 (5/8”)

Liquid

6.35 (1/4”)

6.35 (1/4”)

9.52 (3/8”)

9.52 (3/8”)

9.52 (3/8”)

9.52 (3/8”)

Lo-Mi1-Mi2-Hi

32-34-37-40

33-35-37-40

35-37-39-41

37-39-41-43

39-41-43-45

41-43-45-48

Width

960

1280

1280

1600

1600

1600

Depth

680

680

680

680

680

680

Height

230

230

230

230

230

230

25

32

32

36

38

39

Fed by Outdoor Unit

Fed by Outdoor Unit

Fed by Outdoor Unit

Fed by Outdoor Unit

Fed by Outdoor Unit

Fed by Outdoor Unit

WEIGHT (kg) ELECTRICAL SUPPLy

Single

Single

Single

Single

Single

Single

FUSE RATING (BS88) - HRC (A)

6

6

6

6

6

6

INTERCONNECTING CABLE No. CORES

4

4

4

4

4

4

PHASE

Lower View

Side View

>

>

182

85

1198

PCA-RP100-140KAQ 51

DIMENSIONS (mm)

PUHZ-P100VHA3/YHA PUHZ-P125VHA3/YHA PUHZ-P140VHA3/YHA 54 / 50 (47)

55 / 51 (48)

56 / 52 (49) 99 / 101

53

53

53

75 / 77

99 / 101

840

840

950

950

950

Depth

330

330

330

330 + 30

330 + 30

330 + 30

943

1350

1350

PHASE SySTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SySTEM RUNNING CURRENT (A) Single Phase 3 Phase

FUSE RATING (BS88) - HRC (A)

850

850

880

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz

220-240v, 50Hz / 380-415v,50Hz 220-240v, 50Hz / 380-415v,50Hz 220-240v, 50Hz / 380-415v,50Hz

Single

Single

Single

Single / 3

Single / 3

Single / 3

1.71 / 1.66

2.02 / 1.77

1.96 / 2.06

3.28 / 3.13

4.12 / 4.09

4.69 / 4.84

1.56 / 1.33

1.84 / 1.42

1.78 / 1.65

2.92 / 2.66

3.67 / 3.48

4.17 / 4.11

6.75

9.75

8.89

8/3

11 / 4

11 / 4

6.72 / 7.12 [16.4]

10.14 / 8.74 [16.4]

9.37 / 9.27 [16.5]

15.73 / 14.09 [28.7]

18.55 / 18.42 [28.8]

21.09 / 21.97 [30.4]

-

-

-

5.33 / 5.09 [13.7]

6.54 / 6.50 [13.8]

7.44 / 7.67 [13.9]

20

20

20

32 / 16

32 / 16

32 / 16

MAINS CABLE No. Cores

3

3

3

3/5

3/5

3/5

MAX PIPE LENGTH (m)

30

30

30

50

50

50

MAX HEIGHT DIFFERENCE (m)

30

30

30

30

30

30

CHARGE R410A (kg)

1.6

1.8

1.8

3.0

4.5

4.5

Front View

>

Lower View

236

55 / 55

840

Height

[MAX]

SUZ-KA71VA2

55 / 53

Width

ELECTRICAL SUPPLy

Heating/Cooling

SUZ-KA60VA2

55 / 53

10 5

> 680

WEIGHT (kg)

SUZ-KA50VA2

84 88 195 230

Heating/Cooling (silent)

2

57

NOISE (dBA)

1600 1493

476

MODEL REFERENCE

2

254

SUZ-KA / PUHZ-P - OUTDOOR UNITS

182

85

1518

Notes: All units charged to 7m (50-71), 20m (100) and 30m (125-140) pipe length.

Page 108

Page 109

PCA-RP Standard Inverter Heat Pump

5.5 (0.9-6.6)

Cooling (nominal)

5

236

Heating (nominal)

>

230

PCA-RP140KAQ

Side View

680

PCA-RP125KAQ

195

PCA-RP100KAQ

5

57

PCA-RP71KAQ

1173

10

476

PCA-RP60KAQ

1

254

CAPACITy (kW)

PCA-RP50KAQ

>

2

84 88

Front View

PCA-RP - INDOOR UNITS MODEL REFERENCE

51 1280

2


Stainless Steel Ceiling Suspended System

Dimensions

INDOOR UNIT PCA-RP71HAQ

High performance oil mist filter

I

Easy maintenance - fan casing can be separated into different sections allowing easy cleaning. The drain pan can also be cleaned easily on-site as the pipe connector can be quickly removed

I

1224 1180

110 102

I

>

Front View

The PCA-RP-HAQ series is a ceiling suspended unit ideal for use in kitchen environments. The external casing is made of durable stainless steel that is resistant to oil and smoke, ensuring that the unit can be easily cleaned at all times.

75

986 1136

Optional decoration covers Lower View

Mr Slim Range

PCA-RP-HAQ Power Inverter Heat Pump

> >

650

Side View

280

258

Technical Information PCA-RP-HAQ - INDOOR UNITS 13.8 (5.0-16.0)

Cooling (nominal)

7.1 (3.3-8.1)

12.5 (5.5-14.0)

Heating (UK)

6.45 (3.0-8.65)

11.75 (4.25-13.6)

Cooling (UK)

6.55 (3.05-7.45)

11.5 (5.05-12.9)

SHF (nominal & UK)

0.74

0.77

COP / EER (nominal)

3.41 / 3.21

3.41 / 3.22

ENERGy LABEL

Heating/Cooling

B /A

B /A

AIRFLOW (m3/min)

Lo-Hi

17-19

30-38

PIPE SIZE mm(in)

Gas

15.88 (5/8”)

15.88 (5/8”)

Liquid

9.52 (3/8”)

9.52 (3/8”)

NOISE (dBA)

Lo-Hi

34-38

44-50

DIMENSIONS (mm)

Width

1136

1520

Depth

650

650

Height

280

280

WEIGHT (kg) ELECTRICAL SUPPLy PHASE

41

56

Fed by Outdoor Unit

Fed by Outdoor Unit

Single

Single

FUSE RATING (BS88) - HRC (A)

6

6

INTERCONNECTING CABLE No. CORES

4

4

PUHZ-RP71VHA4

PUHZ-RP125VKA/YKA

48 / 47 (44)

52 / 50 (47)

67

116 / 126

1136

INDOOR UNIT PCA-RP125HAQ Front View

> 1608 1564

1370 1520

PUHZ-RP - OUTDOOR UNITS NOISE (dBA)

Heating/Cooling (silent)

WEIGHT (kg) DIMENSIONS (mm)

Width

950

1050

Depth

330 + 30

330 + 30

Height

943

1338

220-240v, 50Hz

220-240v, 50Hz / 380-415v, 50Hz

Single

Single / 3

Heating/Cooling (nominal)

2.23 / 2.21

4.05 / 3.88

Heating/Cooling (UK)

1.98 / 1.88

3.60 / 3.30

ELECTRICAL SUPPLy PHASE SySTEM POWER INPUT (KW) STARTING CURRENT (A) SySTEM RUNNING CURRENT (A) Single Phase Heating/Cooling

[MAX]

3 Phase

5

5

10.02 / 9.93 [19.4]

18.18 / 17.42 [27.7]

-

7.14 / 6.87 [10.7]

FUSE RATING (BS88) - HRC (A)

20

32 / 16

MAINS CABLE No. Cores

3

3/5

MAX PIPE LENGTH (m)

50

75

MAX HEIGHT DIFFERENCE (m)

30

30

CHARGE R410A (kg) - 30m

3.5

5.0

Page 110

Lower View

75

> Side View

>

650

MODEL REFERENCE

650

PCA-RP-HAQ Power Inverter Heat Pump

PCA-RP125HAQ

7.6 (3.5-10.2)

1520

280

PCA-RP71HAQ Heating (nominal)

110 102

CAPACITy (kW)

258

MODEL REFERENCE

650

Page 111


Stainless Steel Ceiling Suspended System

Dimensions

INDOOR UNIT PCA-RP125HAQ

The new Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the Power Inverter range. High performance oil mist filter

I

Easy maintenance - fan casing can be separated into different sections allowing easy cleaning. The drain pan can also be cleaned easily on-site as the pipe connector can be quickly removed

I

Optional decoration covers

I

3-phase Standard Inverters now available

> 1608 1564

110 102

I

Front View

1370 1520

Lower View

75

>

PCA-RP125HAQ Heating (nominal) Cooling (nominal)

13.8 (5.0-16.0) 12.3 (5.5-14.0)

Heating (UK)

11.75 (4.25-13.6)

Cooling (UK)

11.3 (5.05-12.9)

SHF (nominal & UK)

0.78

COP / EER (nominal)

3.21 / 2.81

ENERGy LABEL

Heating/Cooling

C/C

AIRFLOW (m3/min)

Lo-Hi

30-38

PIPE SIZE mm(in)

Gas

15.88 (5/8”)

Liquid

9.52 (3/8”)

NOISE (dBA)

Lo-Hi

44-50

DIMENSIONS (mm)

Width

1520

Depth

650

Height

280

WEIGHT (kg)

1520

650

PCA-RP-HAQ Standard Inverter Heat Pump

CAPACITy (kW)

280

258

PCA-RP-HAQ - INDOOR UNITS MODEL REFERENCE

>

650

Side View

Technical Information

56

ELECTRICAL SUPPLy

Fed by Outdoor Unit

PHASE

Single

FUSE RATING (BS88) - HRC (A)

6

INTERCONNECTING CABLE No. CORES

4

PUHZ-P - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)

PUHZ-P125VHA3/YHA Heating/Cooling (silent)

WEIGHT (kg) Width

950

Depth

330 + 30

Height ELECTRICAL SUPPLy

1350 220-240v, 50Hz / 380-415v, 50Hz

PHASE

Single / 3

SySTEM POWER INPUT (KW)

Heating/Cooling (nominal)

4.30 / 4.38

Heating/Cooling (UK)

3.83 / 3.72

STARTING CURRENT (A) SySTEM RUNNING CURRENT (A) Heating/Cooling

55 / 51 (48) 99 / 101

DIMENSIONS (mm)

[MAX]

FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m)

11 / 4 Single Phase 3 Phase

19.11 / 19.47 [29.2] 6.73 / 6.86 [14.2] 32 / 16 3/5 50

MAX HEIGHT DIFFERENCE (m)

30

CHARGE R410A (kg) - 30m

4.5

Page 112

Mr Slim Range

PCA-RP-HAQ Standard Inverter Heat Pump

Page 113


Dimensions

Floor Standing System

INDOOR UNIT PSA-RP71GA Front View

The PSA-RP Floor Standing System complements the Mitsubishi Electric range of indoor units. The sleek, modern design of this unit is ideal for numerous applications including bars and restaurants. I

>

Side View

>

Upper View

>

Upper View

>

Built in controller

Mr Slim Range

PSA-RP Power Inverter Heat Pump

Note: When used with a Mr Slim Multi-Split system. PSA-RP cannot be connected with indoor units of different type.

Technical Information PSA-RP - INDOOR UNITS CAPACITy (kW)

PSA-RP71GA

PSA-RP100GA

PSA-RP125GA

Heating (nominal)

7.6 (3.5-10.2)

11.2 (4.5-14.0)

14.0 (5.0-16.0)

Cooling (nominal)

7.1 (3.3-8.1)

10.0 (4.9-11.4)

12.4 (5.5-14.0)

Heating (UK)

6.45 (3.0-8.65)

9.5 (3.85-11.9)

11.9 (4.25-13.6)

Cooling (UK)

11.4 (5.05-12.9)

6.55 (3.05-7.45)

9.2 (4.5-10.5)

SHF (nominal & UK )

0.73

0.81

0.75

COP / EER (nominal)

3.41 / 3.23

3.41 / 3.34

3.41 / 3.01

ENERGy LABEL

Heating/Cooling

B /A

B /A

B/B

AIRFLOW (m3/min)

Lo-Hi

15-18

24-31

26-33

PIPE SIZE mm(in)

Gas

15.88 (5/8”)

15.88 (5/8”)

15.88 (5/8”)

Liquid

9.52 (3/8”)

9.52 (3/8”)

9.52 (3/8”)

NOISE (dBA)

Lo-Hi

40-45

44-49

46-51

DIMENSIONS (mm)

Width

600

600

600

Depth

270

350

350

Height

1900

1900

1900

WEIGHT (kg) ELECTRICAL SUPPLy

43

51

51

Fed by Outdoor Unit

Fed by Outdoor Unit

Fed by Outdoor Unit

Single

Single

Single

FUSE RATING (BS88) - HRC (A)

6

6

6

INTERCONNECTING CABLE No. CORES

4

4

4

PUHZ-RP71VHA4

PUHZ-RP100VKA/YKA

PUHZ-RP125VKA/YKA

48 / 47 (44)

51 / 49 (46)

52 / 50 (47)

67

116 / 124

116 / 126

Width

950

1050

1050

Depth

330 + 30

330 + 30

330 + 30

PHASE

INDOOR UNIT PSA-RP100-125GA Front View

>

Side View

>

PSA-RP Power Inverter Heat Pump

MODEL REFERENCE

PUHZ-RP - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)

Heating/Cooling (silent)

WEIGHT (kg) DIMENSIONS (mm)

Height ELECTRICAL SUPPLy PHASE SySTEM POWER INPUT (KW)

1338

1338

220-240v, 50Hz / 380-415v, 50Hz

220-240v, 50Hz / 380-415v, 50Hz

Single

Single / 3

Single / 3

Heating/Cooling (nominal)

2.23 / 2.20

3.28 / 2.99

4.11 / 4.12

Heating/Cooling (UK)

1.98 / 1.87

2.92 / 2.54

3.66 / 3.50

5

5

5

9.98 / 9.85 [19.7]

14.69 / 13.39 [27.6]

18.40 / 18.44 [27.7]

STARTING CURRENT (A) SySTEM RUNNING CURRENT (A) Single Phase Heating/Cooling

943 220-240v, 50Hz

[MAX]

3 Phase

-

5.83 / 5.37 [9.1]

7.24 / 7.25 [10.7]

FUSE RATING (BS88) - HRC (A)

20

32 / 10

32 / 16

MAINS CABLE No. Cores

3

3 / 5

3 / 5

MAX PIPE LENGTH (m)

50

75

75

MAX HEIGHT DIFFERENCE (m)

30

30

30

CHARGE R410A (kg) - 30m

3.5

5.0

5.0

Page 114

Page 115


Floor Standing System

Dimensions

INDOOR UNIT PSA-RP100-125GA

The Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the Power Inverter range.

Front View

>

Side View

>

Upper View

>

The PSA-RP Floor Standing System complements the Mitsubishi Electric range of indoor units. The sleek, modern design of this unit is ideal for numerous applications including bars and restaurants. I

Built in controller

I

3-phase Standard Inverters now available

Mr Slim Range

PSA-RP Standard Inverter Heat Pump

Note: When used with a Mr Slim Multi-Split system. PSA-RP cannot be connected with indoor units of different type.

Technical Information MODEL REFERENCE CAPACITy (kW)

PSA-RP100GA

PSA-RP125GA

Heating (nominal)

11.2 (4.5-12.5)

14.0 (5.0-16.0)

Cooling (nominal)

9.4 (4.9-11.2)

12.3 (5.5-14.0)

Heating (UK)

9.5 (3.85-10.65)

11.9 (4.25-13.6)

Cooling (UK)

8.65 (4.5-10.3)

11.3 (5.05-12.9)

SHF (nominal & UK)

0.83

0.76

COP / EER (nominal)

3.41 / 3.01

2.81 / 2.81 D/C

ENERGy LABEL

Heating/Cooling

B/B

AIRFLOW (m3/min)

Lo-Hi

24-31

26-33

PIPE SIZE mm(in)

Gas

15.88 (5/8”)

15.88 (5/8”)

Liquid

9.52 (3/8”)

9.52 (3/8”)

NOISE (dBA)

Lo-Hi

44-49

46-51

DIMENSIONS (mm)

Width

600

600

Depth

350

350

Height

1900

1900

WEIGHT (kg) ELECTRICAL SUPPLy PHASE

51

51

Fed by Outdoor Unit

Fed by Outdoor Unit

Single

Single

FUSE RATING (BS88) - HRC (A)

6

6

INTERCONNECTING CABLE No. CORES

4

4

PSA-RP Standard Inverter Heat Pump

PSA-RP - INDOOR UNITS

PUHZ-P - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)

Heating/Cooling (silent)

WEIGHT (kg) DIMENSIONS (mm)

PUHZ-P125VHA3/YHA

54 / 50 (47)

55 / 51 (48)

75 / 77

99 / 101

Width

950

950

Depth

330 + 30

330 + 30

Height ELECTRICAL SUPPLy PHASE SySTEM POWER INPUT (KW)

PUHZ-P100VHA3/YHA

943

1350

220-240v, 50Hz / 380-415v, 50Hz

220-240v, 50Hz / 380-415v, 50Hz

Single / 3

Single / 3

Heating/Cooling (nominal)

3.28 / 3.12

4.98 / 4.38

Heating/Cooling (UK)

2.92 / 2.65

4.43 / 3.72

STARTING CURRENT (A)

8/3

11 / 4

14.55 / 13.84 [29.1]

22.08 / 19.42 [29.2]

5.23 / 4.97 [14.1]

7.78 / 6.84 [14.2]

32 / 16

32 / 16

3/5

3/5

MAX PIPE LENGTH (m)

50

50

MAX HEIGHT DIFFERENCE (m)

30

30

CHARGE R410A (kg)

3.0

4.5

SySTEM RUNNING CURRENT (A) Heating/Cooling

[MAX]

Single Phase 3 Phase

FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores

Notes: All units charged to 20m (100) and 30m (125) pipe length.

Page 116

Page 117


Dimensions

Heat Pump Air Curtain System

AIR CURTAIN PHV1000/1500/2000R DXE

In collaboration with Thermoscreens 速, Mitsubishi Electric have developed a range of air cur tains that can be connected to our Power Inver ter heat pumps, as opposed to the more traditional direct electric method associated with air cur tains. I

Reduced CO2 emissions (up to 67%)

I

Reduced Running Costs (up to 67%)

I

2.5 year payback period against equivalent Electric system

I

Inverter technology (does not waste energy)

I

Range of different sizes to suit every application

I

Allows open door policy in retail outlets whilst being energy efficient

I

Clean environment - protection from dust, fumes etc

I

Comfortable climate for customers

I

Easy to install and maintain

Side View

>

Rear View

>

Upper View

Mr Slim Range

PHV DXE Heat Pump Air Curtain

>

Technical Information PHV DXE - RECESSED MODEL REFERENCE DIMENSIONS (mm) (WxDxH) SUPPLy (50Hz)

PHV1000R DXE HO

PHV1500R DXE LO

PHV1500R DXE HO

PHV2000R DXE LO

PHV2000R DXE HO

1150x436x296

1650x436x296

1650x436x296

2240x436x296

2240x436x296

415V*1

415V*1

415V*1

415V*2

415V*2

HEAT OUTPUT (kW)

100% / 50%

8.6 / 5.34

10.1 / 5.6

14.4 / 8.3

14.1 / 7.9

21.3 / 11.2

COP

100% / 50%

2.4 / 3.15

2.3 / 3.4

2.5 / 3.7

2.9 / 3.7

2.4 / 3.2

LOADING (amps)

7.8*1

12.7*1

12.7*1

15.7*2

15.7*2

VELOCITy (m/s)

9

9

9

9.5

9

AIR VOLUME (m3/h)

1400

2500

2600

3300

3130

WEIGHT (kg)

45

66

67

85

88

NOISE dB(A) @ 3m

56

58

58

59

59

MAX. MOUNTING HEIGHT (m)

3.5

3.5

3.5

3.5

3.5

PUHZ-RP71VHA4

PUHZ-RP71VHA4

PUHZ-RP140VKA/yKA

PUHZ-RP100VKA/yKA

PUHZ-RP200yKA

OUTDOOR UNIT MODEL

Notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load (1.3 amp load for PHV1000R DXE HO)

AIR CURTAIN PHV1000/1500/2000 DXE Side View

>

Rear View

>

*2 for units with electric heaters disabled, 240v power supply 2.7 amp load.

PHV DXE - FREE STANDING DIMENSIONS (mm) (WxDxH) SUPPLy (50Hz)

PHV1000 DXE HO

PHV1500 DXE LO

PHV1500 DXE HO

PHV2000 DXE LO

PHV2000 DXE HO

1196x377x255

1746x377x255

1746x377x255

2296x377x255

2296x377x255

415V*1

415V*1

415V*1

415V*2

415V*2

HEAT OUTPUT (kW)

100% / 50%

8.6 / 5.34

10.1 / 5.6

14.4 / 8.3

14.1 / 7.9

21.3 / 11.2

COP

100% / 50%

2.4 / 3.15

2.3 / 3.4

2.5 / 3.7

2.9 / 3.7

2.4 / 3.2

LOADING (amps)

7.8*1

12.7*1

12.7*1

15.7*2

15.7*2

VELOCITy (m/s)

9

9

9

9.5

9

1400

2500

2600

3300

3130

39

59

60

78

80

AIR VOLUME (m3/h) WEIGHT (kg) NOISE dB(A) @ 3m MAX. MOUNTING HEIGHT (m) OUTDOOR UNIT MODEL

56

58

58

59

59

3.75

3.75

3.75

3.75

3.75

PUHZ-RP71VHA4

PUHZ-RP71VHA4

PUHZ-RP140VKA/yKA

PUHZ-RP100VKA/yKA

PUHZ-RP200yKA

Notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load (1.3 amp load for PHV1000 DXE HO)

*2 for units with electric heaters disabled, 240v power supply 2.7 amp load.

Upper View

> PHV DXE Air Curtain

MODEL REFERENCE

PHV1000 DXE PHV1500 DXE PHV2000 DXE

HEAT PUMP OUTDOOR UNITS MODEL REFERENCE

PUHZ-RP71VHA4

PUHZ-RP100VKA/YKA

PUHZ-RP140VKA/YKA

PUHZ-RP200YKA

950x330+30x943

1050x330+30x1338

1050x330+30x1338

1050x330+30x1338

230V

230V / 415V

230V / 415V

415V

MAX. CURRENT (A)

19

26.5 / 8

28 / 11

19

FUSE SIZE HRC (BS88)

20

32 / 10

32 / 16

20

50

50

50

100

DIMENSIONS (mm) (WxDxH) SUPPLy (50Hz)

MAX. PIPE RUN PIPE SIZES

Length (m) Height (m)

30

30

30

30

Gas mm(in)

15.88 (5/8)

15.88 (5/8)

15.88 (5/8)

28.58 (1 1/8)

Liquid mm(in)

9.52 (3/8)

9.52 (3/8)

9.52 (3/8)

9.52 (3/8)

2 core

2 core

2 core

2 core

INTERCONNECTING CABLE

Page 118

Page 119


Sensible Cooling Wall Mounted System

INDOOR UNIT PHV2000 NT

In collaboration with Thermoscreens®, Mitsubishi Electric have developed a sensible cooling wall mounted unit that can be connected to our air to water heat pumps in cooling mode. These systems offer 100% sensible cooling (SHF of 1) for use in server rooms and other sensible cooling applications. SHF of 1 and capacity validated by 3rd party assessment (BSRIA)

I

Reduced CO2 emissions

I

Reduced Running Costs

I

Inverter technology (does not waste energy)

I

Easy to install and maintain

I

Ideal for small to medium size server rooms / laboratories

I

No 3rd party humidifier is required

I

PAR-W21MAA controller included

I

Pump not included

Side View

>

Rear View

>

C. 150min. for pipes

I

Dimensions

295

255

Upper View Upper View

>

>

168

Technical Information

Mr Slim Range

PHV NT Chilled Water Heat Pump

PHV NT - INDOOR UNITS MODEL REFERENCE

2296

Depth

377

Height

255

Cooling

12.0

SHF

1.0

EER

3.8

ELECTRICAL SUPPLy

OUTDOOR UNIT PUHZ-HW140VHA2 / PUHZ-HW140yHA2

220-240v, 50Hz Rear Air Intake

2.7

VELOCITy (m/s)

9

AIR VOLUME (m3/h)

Upper View

2885

WEIGHT (kg)

>

210

59

Side Air Intake

53

36 5.1

30

HyDRAULIC RESISTANCE (kPa @ 3.18 m3/h) WATER VOLUME OF COIL (litres)

330

3.18

Notes: Water flow temperature to be set to 10ºC (cannot be set lower). Includes room/return air temperature control, remote On/Off and room over-heat alarm. Test conditions: 35ºC DB / 27ºC WB outdoor conditions, 24ºC DB / 40% relative humidity indoor conditions - validated by BSRIA assessment.

Air Discharge

Front View PUHZ-HW - OUTDOOR UNITS

>

1020

1020

Depth

330 + 30

330 + 30

Height PHASE AIRFLOW (m3/min)

1350

1350

220-240v, 50Hz

380-415v, 50Hz

Single

3

100

100

HyDRAULIC RESISTANCE (kPa @ 3.18 m3/h)

15

15

WATER VOLUME IN HEAT EXCHANGER (litres)

2.5

2.5 7.6 [13]

40

16

MAINS CABLE No. CORES

3

5

CHARGE R410A (kg)

4.3

4.3

OPERATING RANGE

-5ºC ~ +46ºC

-5ºC ~ +46ºC 23

22.2 [35]

FUSE RATING (BS88) - HRC (A)

40

Width

74

148

VHA 1079 YHA 931

134

635

53

WEIGHT (kg)

ELECTRICAL SUPPLy

>

PUHZ-HW140YHA2

53

1350

PUHZ-HW140VHA2

NOISE (dBA)

Page 120

Side View

1020 322

MODEL REFERENCE

RUNNING CURRENT (A) [MAX]

370

WATER VOLUME FLOW RATE (m3/h)

210

28

NOISE (dBA) @ 3m

DIMENSIONS (mm)

600 Installation Feet

90

PHV NT Sensible Cooling Chilled Water Heat Pump

LOADING (A)

19

Single

417

PHASE

371

CAPACITy (kW)

PHV2000 NT Width

36

DIMENSIONS (mm)

34

Page 121


Technical Information

Inverter Heat Pump

Multi-Split Systems - Combinations Table

The multi-split system is an ideal option for open plan spaces in medium sized premises such as offices or shops, where two, three or four units are required. These can be Mr Slim ceiling cassettes (PLA-RP & SLZ-KA), ceiling suspended (PCA-RP), ducted (PEAD-RP), floor standing (PSA-RP) or wall mounted (PKA-RP) models and can be connected to a single outdoor unit using twin, triple or quadruple multi distributor pipes. I

Twin, triple or quadruple indoor heat pump units can be operated in Multi-Split configuration from a single outdoor unit

Indoor Unit

Outdoor Heat Pump

No. of Indoor Units

Total Heating Capacity (kW)

Total Cooling Capacity (kW)

Pipe Kit Part Number

Size 35

PUHZ-RP71

2

3.5 - 10.2

3.3 - 8.1

MSDD-50TR-E

Size 35

PUHZ-HRP71

2

4.5 - 10.2

4.9 - 8.1

MSDD-50TR-E

Size 50

PUHZ-P100

2

4.5 - 12.5

4.9 - 11.2

MSDD-50TR-E

I

Heat pumps must operate in same heating or cooling mode

Size 50

PUHZ-RP100

2

4.5 - 14.0

4.9 - 11.4

MSDD-50TR-E

I

Cooling capacity range 3.3 to 28kW

Size 50

PUHZ-HRP100

2

4.5 - 14.0

4.9 - 11.4

MSDD-50TR-E

I

Heating capacity range 3.5 to 31.5kW

Size 60

PUHZ-P125

2

5.0 - 16.0

5.5 - 14.0

MSDD-50TR-E

I

SLZ-KA indoor units can now be connected as part of a Mr Slim Multi-Split system

Size 60

PUHZ-RP125

2

5.0 - 16.0

5.5 - 14.0

MSDD-50TR-E

Size 60

PUHZ-HRP125

2

5.0 - 16.0

5.5 - 14.0

MSDD-50TR-E

Size 71

PUHZ-P140

2

5.0 - 18.0

5.5 - 15.0

MSDD-50TR-E

Size 71

PUHZ-RP140

2

5.0 - 18.0

5.5 - 15.3

MSDD-50TR-E

Size 50

PUHZ-P140

3

5.0 - 18.0

5.5 - 15.0

MSDT-111R-E

Note: SEZ-KD indoor units cannot be used as part of a Mr Slim Multi-Split system. PSA-RP indoor units cannot be connected with indoor units of different type. PCA-RP, PSA-RP and SLZ-KA indoor units cannot be connected to PUHZ-HRP outdoor units. PKA-RP indoor units cannot be connected to PUHZ-HRP71 & PUHZ-HRP125 outdoor units.

Technical Information

PIPE RUN PARAMETERS Outdoor Model

Pipe Runs

Max. Pipe Run (m)

Size 50

PUHZ-RP140

3

5.0 - 18.0

5.5 - 15.3

MSDT-111R-E

PUHZ-P100-140VHA3/yHA

A+B+C twin

50

PUHZ-P200/250yHA3

A+B+C twin

70

Size 100

PUHZ-P200

2

9.5 - 25.0

9.0 - 22.4

MSDD-50WR-E

Size 60

PUHZ-P200

3

9.5 - 25.0

9.0 - 22.4

MSDT-111R-E

Size 50

PUHZ-P200

4

9.5 - 25.0

9.0 - 22.4

MSDF-1111R-E

Size 100

PUHZ-RP200

2

9.5 - 25.0

9.0 - 22.4

MSDD-50WR-E

Size 60

PUHZ-RP200

3

9.5 - 25.0

9.0 - 22.4

MSDT-111R-E

Size 50

PUHZ-RP200

4

9.5 - 25.0

9.0 - 22.4

MSDF-1111R-E

Size 125

PUHZ-P250

2

12.5 - 31.5

11.2 - 28.0

MSDD-50WR-E

Size 71

PUHZ-P250

3

12.5 - 31.5

11.2 - 28.0

MSDT-111R-E

Size 60

PUHZ-P250

4

12.5 - 31.5

11.2 - 28.0

MSDF-1111R-E

Size 125

PUHZ-RP250

2

12.5 - 31.5

11.2 - 28.0

MSDD-50WR-E

Size 71

PUHZ-RP250

3

12.5 - 31.5

11.2 - 28.0

MSDT-111R-E

Size 60

PUHZ-RP250

4

12.5 - 31.5

11.2 - 28.0

MSDF-1111R-E

PUHZ-RP71VHA4

A+B+C twin

50

PUHZ-RP100-140VKA/yKA

A+B+C twin

75

PUHZ-RP200/250yKA

A+B+C twin

80 (120)

A+B+C twin

75

PUHZ-P140VHA3/yHA

A+B+C+D triple

50

PUHZ-P200/250yHA3

A+B+C+D triple

70

PUHZ-RP140VKA/yKA

A+B+C+D triple

75

PUHZ-RP200/250yKA

A+B+C+D triple

80 (120)

PUHZ-P200/250yHA3

A+B+C+D+E quadruple

70

A+B+C+D+E quadruple

80 (120)

PUHZ-P100-140VHA3/yHA

PUHZ-RP200/250yKA

B – C or C – D or B – D

PUHZ-RP71-140VHA4/VKA/yKA

B – C or C – D or B – D

≥8 ≥8 ≥8 ≥8 ≥8

PUHZ-HRP71-125VHA2/yHA2

B-C

PUHZ-P200/250yHA3

B - C or B - D or B - E or C - D or C - E or D - E

PUHZ-RP200/250yKA

B - C or B - D or B - E or C - D or C - E or D - E

H = 30m.

h = 1m.

Note: H for the PUHZ-RP200/250YKA = 40m

TWIN Indoor Units

Indoor Units

B

h

h

Page 122

B

C h

D

Indoor Units B

C

h Multi distributor Pipes

Outdoor Units

Multi distributor H Pipes

QUADRUPLE

TRIPLE

A

C D

Outdoor Units Multi distributor Pipes

A H

Multi-Split Systems

PUHZ-HRP71-125VHA2/yHA2

Mr Slim Range

Mr Slim Multi-Split Systems

A

E Outdoor Units

H

Page 123


Dimensions

SUZ-KA71VA2

SUZ-KA25/35VA2

>

400 Air in

Air in

17.5

40

Front View

Side View

Air out

>

>

Bolt pitch for installation 304~325

Upper View

44

285

344.5

Upper View

>

23

22.3

>

>

43

Side View

10

164.5

280

35

550

Front View

Mr Slim Range

Outdoor Units

150

99.5

69

170.5

302.5 500 Bolt pitch for installation 800

SUZ-KA50/60VA2 515

>

PUHZ-P100VHA3 / PUHZ-P100YHA

299 66

Air in

40

51 34

Upper View

Upper View

>

175

600

175 (19)

360

Installation Feet

A B C PUHZ-P100VHA3 443 670 66 PUHZ-P100YHA 431 589 56

370 417

330

Side Air Intake

Air out

840 121

F 56 54

>

C

D

53

Side View

80

28

>

30

Front View

E 45 41

E F

500

D 42 41

Air Discharge

>

Side View

950 322

>

A 23

155 90

35

447

473

30

430

B

943

850

Front View

Outdoor Unit Dimensions

330

Rear Air Intake

Air in

198

Dimensions Page 124

Page 125


Dimensions

PUHZ-P125/140VHA3 / PUHZ-P125/140YHA

PUHZ-RP35/50VHA4 400

A A PUHZ-P125/140VHA3 1076 PUHZ-P125/140VHA3 1076 PUHZ-P125/140YHA 994 PUHZ-P125/140YHA 994

417

41 54 370

330

Side Air Intake

Air intake

Air intake

330

Installation Feet

>

365

Upper View

175

300

600

155

175

152

>

(19)

Upper View

347.5 43.6

Rear Air Intake

Air Discharge

Front View

>

Side View

322

>

Side View

Air discharge

>

>

23 18

150

43

90

155

300 A

10

635

1350

35

600

Front View

950

40

32.5

41

53 28

30

45.4 56

Mr Slim Range

Outdoor Units

183

69 Installation bolt pitch: 500

447

371

431

287.5

23

800

PUHZ-RP60/71VHA4

PUHZ-P200/250YHA3

Rear air intake

A PUHZ-P200YHA3 PUHZ-P200YHA3 447 PUHZ-P250YHA3 PUHZ-P250YHA3 421

417

A 447 421

950

Side View

322

> Front View

57

41

Air discharge

>

Side View

950

>

447

431

473

439

A

23

23

371

339

673

943

995 999

635

1350

322

Dimensions Page 126

Page 127

Outdoor Unit Dimensions

>

29

Air Discharge

Front View

175

28

37

600 Installation Feet

53 28

40 56 370

330

61

175

Side air intake

Side Air Intake

30

>

19

Installation Feet

417

Upper View 175

40 54

600

53

175

330

>

(19)

Upper View

370

Rear Air Intake


Dimensions

PUHZ-RP100-140VKA / PUHZ-RP100-140YKA

PUHZ-HRP71/100VHA2 / PUHZ-HRP100/140YHA2

600 Installation Feet

Upper View

225

Rear air intake

175

Model A PUHZ-RP100-140VK A 1067 PUHZ-RP100-140YK A 919

70

60

42

600

175

Installation Feet

A

Side air intake 330

56 40 0 53

28

330

370 417

Side air intake

30

>

HRP.VHA2 HRP.YHA2

417

225

45 56 370

>

19

Upper View

(19)

Rear air intake

1079 930

66

42

53 28

30

Air discharge Air discharge

>

Side View

1050

>

Front View

>

Side View

950 322

>

447

443

26

371

369

442 450

A

635

A

1350

632

362

1338

Front View

Mr Slim Range

Outdoor Units

>

Rear air intake 600 Installation Feet

225

Model PUHZ-RP200YKA PUHZ-RP250YKA

Air discharge

>

60

42

B 442

56 40 0 53

Side View

1050 362

>

26

342 A B

369

982 986

632

1338

Front View

70

A 450 424

28

30

330

370 417

Side air intake

Outdoor Unit Dimensions

225

19

Upper View

23

PUHZ-RP200/250YKA

Dimensions Page 128

Page 129


M Series

The Air Handling Unit Controllers are an interface to allow connection to third party manufacturer equipment. Mitsubishi Electric Mr Slim outdoor units can be used with this interface box, creating an ideal solution when a unique air handling unit is required. I

No need for expansion device

I

Error, operation and defrost output

I

Demand control by analogue or digital inputs (0-10Ω , 4-20mA, 1-5V, 0-10V, Step, Auto-Step)

I

Now includes a third thermistor to enable Auto-Step

Wall Mounted Units

S70 515 716 S71 000 028

- Terminal block - CN22 connector

Ceiling Concealed Ducted Units

MAC-399IF MAC-397IF

- Interface for connection to M-NET System SEZ-KD25-71VAQ - Interface for group control and run/fault SEZ-KD25-71VAQ

4-Way Blow Cassette Units

PLP-6BA SLP-2AAW PAC-SH53TM-E PAC-SH59KF-E PLP-6BALM PLP-6BAJ PAC-SA1ME-E PAR-SA9FA-E S70E40714 MAC-399IF MAC-397IF

- Grille for PLA-RP35-140BA(2)(3) - Grille for SLZ-KA25-50VAQ - Multi function casement PLA-RP35-140BA(2)(3) for fresh air 100mm knockout or to hold the high efficiency filter option - High efficiency filter PLA-RP35-140BA(2)(3) - Grille and infra-red controller PLA-RP35-140BA(2)(3) - Grille with filter lowering function PLA-RP35-140BA(2)(3) - ‘I-See Sensor’ corner panel PLA-RP35-140BA(2)(3) - Infra-red signal receiver PLA-RP35-140BA(2)(3) - Infra-red controller (PAR-SL97A-E) PLA-RP35-140BA(2)(3) - Interface for connection to M-NET System SLZ-KA25-50VAQ - Interface for group control and run/fault SLZ-KA25-50VAQ

Ceiling Suspended Units

PAR-SL94B-E PAC-SH83DM-E PAC-SH85DM-E PAC-SH84DM-E PAC-SG38KF-E PAC-SF81KC-E PAC-SF82KC-E

-

Outdoor Units

PAC-SG61DS-E

PAC-SH95AG-E

- Drain socket set PUHZ-RP35-250VHA4/VKA/YKA / PUHZ-P100-250VHA3/YHA/YHA3 / PUHZ-HRP71-125VHA2/YHA2 - Air outlet guide PUHZ-RP35-50VHA4 - Air outlet guide PUHZ-RP60-71VHA4 / PUHZ-P100VHA3/YHA / PUHZ-P125-250VHA3/YHA/YHA3 (2 sets required) / PUHZ-HRP71-125VHA2/YHA2 (2 sets required) - Air outlet guide PUHZ-RP100-250VKA/YKA (2 sets required) - Air protect guide (allows cooling at -15ºC) PUHZ-RP35-50VHA4 - Air protect guide (allows cooling at -15ºC) PUHZ-RP60-71VHA4 / PUHZ-P100VHA3/YHA / PUHZ-P125-250VHA3/YHA/YHA3 (2 sets required) / PUHZ-HRP71-125VHA2/YHA2 (2 sets required) - Air protect guide (allows cooling at -15ºC) PUHZ-RP100-250VKA/YKA (2 sets required)

System Control Units

PAC-SA89TA-E PAC-SF40RM-E PAC-SE41TS-E PAC-SF81MA PAC-YT51CRB PAR-30MAA PAC-SK82SI-E

-

Remote on/off adaptor Run/fault indication Remote sensor A/M-NET adaptor Simplified remote controller Wired controller Sub interface board

Pipe Kits

MSDD-50TR-E MSDD-50WR-E MSDT-111R-E MSDF-1111R-E

-

Multi distribution pipe twin units - 50:50 - sizes 71/100/125/140 Multi distribution pipe twin units - 50:50 - sizes 200/250 Multi distribution pipe triple units - 33:33:33 - sizes 140/200/250 Multi distribution pipe quadruple units - 25:25:25:25 - sizes 200/250

Power Supply Terminal Kits

PAC-SH52HR-E PAC-SG94HR-E PAC-SG96HR-E PAC-SG97HR-E

-

Power supply terminal kit for PLA-RP when using PUHZ-RP200/250YKA Power supply terminal kit for PKA-RP when using PUHZ-RP200/250YKA Power supply terminal kit for PCA-RP / PSA-RP when using PUHZ-RP200/250YKA Power supply terminal kit for PEAD-RP / PCA-RP-HAQ when using PUHZ-RP200/250YKA

Technical Information PAC-IF012B-E MITSUBISHI ELECTRIC OUTDOOR UNIT CAPACITy (kW) AUTO STEP

SIZE 35

SIZE 50

SIZE 60

SIZE 71

SIZE 100

SIZE 125

SIZE 140

SIZE 200

SIZE 250

Heating (nominal)

4.1

6.0

7.0

8.0

11.2

14.0

16.0

22.4

27.0

Cooling (nominal)

3.6

5.0

6.0

7.1

10.0

12.5

14.0

19.0

22.0

VHA4

VHA4

VHA4

VHA4

VKA/yKA

VKA/yKA

VKA/yKA

yKA

yKA

PUHZ-RP PUHZ-P

-

-

-

-

VHA3/yHA

VHA3/yHA

VHA3/yHA

yHA3

yHA3

SUZ-KA

VA2

VA2

VA2

VA2

-

-

-

-

-

VHA2

VHA2/yHA2

yHA2

VHA4

VHA4

VHA4

VHA4

VKA/yKA

VKA/yKA

VKA/yKA

yKA

yKA

VHA2

VHA2/yHA2

yHA2 28.58 / 12.7

PUHZ-HRP MANUAL STEP

PUHZ-RP PUHZ-HRP

PIPE SIZE (mm)

PUHZ-(H)(R)P

12.7 / 6.35

12.7 / 6.35

15.88 / 9.52

15.88 / 9.52

15.88 / 9.52

15.88 / 9.52

15.88 / 9.52

28.58 / 9.52

Gas / Liquid

SUZ-KA

9.52 / 6.35

12.7 / 6.35

15.88 / 6.35

15.88 / 9.52

-

-

-

-

-

HEAT EXCHANGER VOLUME (cm3)

Max Capacity

1050

1500

1800

2130

3000

3750

4200

6000

7500

Min Capacity

350

500

600

710

1000

1250

1400

2000

2500 336

DIMENSIONS (mm)

Width

336

336

336

336

336

336

336

336

Depth

69

69

69

69

69

69

69

69

69

Height

278

278

278

278

278

278

278

278

278

2.5

2.5

2.5

2.5

2.5

2.5

2.5

2.5

2.5

WEIGHT (kg)

PAC-SG58SG-E PAC-SG59SG-E PAC-SH96SG-E PAC-SG56AG-E PAC-SH63AG-E

Note: One air handling unit controller is required per air handling unit Cooling: Indoor 27ºC DB/19ºC WB, Outdoor 35ºC DB/24ºC WB Heating: Indoor 20ºC DB, Outdoor 7ºC DB/6ºC WB

Example:

Air Handling Unit Controller (Mitsubishi Electric)

A Control wiring

Wireless remote controller and adaptor Optional drain lift pump PCA-RP50KAQ Optional drain lift pump PCA-RP60KAQ Optional drain lift pump PCA-RP71-140KAQ Oil mist filter for PCA-RP71/125HAQ (12 pack) Decoration covers (front cover & suspending bracket) for PCA-RP71HAQ Decoration covers (front cover & suspending bracket) for PCA-RP125HAQ

Controller (field supplied)

Thermistor wiring

Piping

Outdoor Unit (Mitsubishi Electric)

Page 130

Air Handling Unit (field supplied)

Page 131

Air Handling Unit Controller / Accessories / Optional Extras

Air Handling Unit Controller

Mr Slim Range

Accessories / Optional Extras

PAC-IF012B-E


City Multi Energy Efficient VRF Systems

Air Conditioning Commercial Heating Domestic Heating Photovoltaics


The City Multi Range: Solutions for More Demanding Applications

Efficient and Flexible The City Multi range is Mitsubishi Electric’s answer to large scale VRF (Variable Refrigerant Flow) applications. The efficiency of City Multi is second to none and offers a substantial increase in energy efficiency, with corresponding EER/COP ratings.

The strength of

City Multi The R410A YJM-A series offers some of the highest EER/COP ratings in the market.

The City Multi Y Series range offers a simple and flexible solution where there is a demand for a changeover capability between heating and cooling, helping to ensure a constant, comfortable indoor climate. Mitsubishi Electric also has the ability to provide simultaneous heating and cooling through its R2 and WR2 systems. This is achieved through only two pipes rather than the conventional three. Further developments with the City Multi range now enable heat to be moved to areas of a building that can best make use of it, these include air curtains and the generation of hot water. By moving heat in this way the system becomes central to providing a wider range of environmental services and further increases the run cost and CO2 emission reductions you would normally expect, as well as generating the hot water from this renewable heat source. By using Mitsubishi Electric’s 2-pipe heat recovery technology, substantial savings can again be made on annual running costs. With a range of over 80 indoor units, up to 50 (depending on the capacity available) can be connected to a YJM-A outdoor unit. Broadening the range of potential City Multi applications is Mitsubishi Electric’s 4th generation water cooled R410A WR2 system. This system not only produces heat recovery from the refrigerant circuit but also via its water circuit, offering double heat recovery potential.

Sophisticated technology, combined with a high level of control and energy efficiency: City Multi is perfectly positioned to meet the demands of today’s market.

Page 134

Page 135


The Basics: What is VRF? VRF stands for Variable Refrigerant Flow. A VRF air conditioning system modulates the flow of refrigerant depending upon the capacity requirements of the building. A VRF system comprises of a condensing unit sited externally and a series of multiple indoor units to provide cooling and/or heating to the occupied space.

Our Answer to VRF Mitsubishi Electric sets the boundaries of VRF technology with the City Multi range, which is available using R410A refrigerant. The range has been specifically designed for today's building requirements and addresses key market issues such as energy efficiency, adaptability and reliability. Mitsubishi Electric manufactures the only 2-pipe heat recovery simultaneous heating and cooling system in the world and equally unique, a water-cooled version. With user friendly control systems utilising internet technology and integrated cooling and ventilation indoor units, City Multi is the benchmark and market leader in VRF technology.

What is Inverter Driven Technology? Mitsubishi Electric spends more than 5% of its turnover on research and development, with our engineers always looking at ways in which we can improve and lead in air conditioning efficiency. The use of inverter technology in our City Multi systems is paramount in this process, working by varying the compressor speed to match the cooling or heating load, thereby consuming only the power necessary to match the exact requirement of the room. When City Multi is operating at partial load, the energy efficiency of the system is significantly higher than at full load. In a typical application partial load conditions prevail for more than 90% of operation time. A fixed speed system can only operate at 100% capacity and cannot match the annual efficiencies of an inverter system

What is a Heat Pump System? Mitsubishi Electric’s City Multi Y and WY Series’ are heat pump systems, which provide either heating or cooling to a building at any given time.

What is a Heat Recovery System?

Why R410A? R410A is a more efficient refrigerant as it has a higher specific heat capacity when compared to R407c or R22. This higher energy carrying capacity allows for smaller pipe sizes, longer pipe runs and reduces the volume of refrigerant within a system. This is a major factor when complying with EN378, a European standard concerning safety and environmental requirements in the design, manufacture, installation, operation, maintenance and disposal of refrigerating systems.

How Does the R2 / WR2 Heat Recovery System Operate on 2 Pipe’s? The secret of City Multi heat recovery systems lies in the BC Controller

Why Heat Recovery? Flexibility and efficiency are key factors when selecting a heat recovery system. For example, while a heat pump system is adequate for a large open plan office, businesses that have a more partitioned structure to an office will require the need to simultaneously heat or cool different sections of the office according to each users individual preferences. The efficiency of this type of system comes from the ability to use the by-products of cooling and heating to transfer energy where it is required, thus acting as a balanced heat exchanger achieving up to 20% cost savings over a conventional heat pump system. The number of connection sites needed for a R2 / WR2 system are also significantly lower than those needed for a three pipe version. This helps to reduce installation costs, further increasing the savings associated with City Multi.

The BC Controller houses a liquid/gas separator, allowing the outdoor unit to deliver a mixture (2 phase) of hot gas for heating and liquid for cooling, all through the same pipe. Three pipe systems allocate a pipe to each of these phases. When this mixture arrives at the BC Controller, it is separated and the correct phase delivered to each indoor unit depending on the individual requirement of either heating or cooling.

Comparison Example of Piping Connection Sites

Mitsubishi Electric’s City Multi R2 and WR2 Series’ have the ability to provide heating and cooling at the same time in areas connected to the same outdoor unit.

Page 136

Page 137


The Technology to Make City Multi the Natural Choice

Total Energy Conservation

Energy efficiency has always been the driver for City Multi technological development that always delivers the quality and reliability needed for commercial air conditioning environments. Mitsubishi Electric spend more than 5% of their turnover on research and development, with our engineers always looking at ways in which we can improve and lead in air conditioning efficiency.

City Multi R410A YJM-A Technology

Stable and Smooth Operation: 100% Inverter Control

Using the ver y latest in IPM (Intelligent Power Module) technology, precise control of energy input is achieved allowing City Multi to fur ther improve COPs for R410A systems. IPM uses 1Hz steps of capacity control, matching building requirements through more accurate control of the occupied space with reduced power input.

All City Multi compressors are inverter-driven and capable of precisely matching a building's cooling and heating demands.

As in previous versions, IPM technology operates extremely effectively under part load conditions (50-80% of operating capacity), a condition that most systems will be in for their normal working life. Therefore the consideration of efficiency at part load is accounted for as well as when at peak load conditions, offering high system efficiency all year round.

The outdoor unit combinations comprise of one module for 8-18hp systems, two modules for 20-36hp systems and three modules for 38-50hp systems (Y series only). Each module carries one inverter compressor making simple and highly reliable control possible. Not only does it allow low starting currents, the inverter driven compressor also provides precise indoor comfort and adapts to the air conditioning load, achieving smooth transition across the range of compressor frequencies

Heat Interchange Circuit

The Importance of COP

To further enhance the class leading efficiency of City Multi, the unique Heat Interchange Circuit provides extra sub cooling. This system allows optimum refrigerant distribution to multiple indoor units, by allowing more effective use of refrigerant flowing through the electronic expansion valves.

COP stands for “Co-efficient of Performance�. It is a measure of the useful energy a system can deliver compared to the energy that it consumes. It is calculated by dividing the energy output by the energy input of a system. The higher the figure then the more efficient the system is deemed to be, with commensurate reduced running costs.

Because of the added efficiency, volumes of refrigerant in systems are continuing to reduce.

City Multi Systems: 8-18hp

For Heat Pumps to be included on the Energy Technology Product List under the Enhanced Capital Allowance scheme, they must fall within the criteria specified by the ECA. For further information on qualification please visit www.eca.gov.uk

Total Energy Conservation CITY MULTI REFRIGERANT CIRCUIT

NORMAL REFRIGERANT CIRCUIT

Comparison of COP (energy efficiency) of an 8hp YJM-A system.

City Multi Systems: 20-36hp

The Difference Between YJM-A and Previous Mitsubishi Electric Models City Multi Systems: 38-50hp

31%

4.13

36%

4.46

Technology is key when increased efficiency is demanded. The City Multi YJM-A range is designed to deliver this. A highly efficient R410A scroll compressor design results in less friction losses at the motor. A simplified refrigerant circuit (low pressure loss) including new accumulator design also adds a few more points to the efficiency scale. Enhancements to the heat interchange circuit, inverter driven fan motor and heat exchanger design, again add vital increases to overall system efficiency and COPs.

Page 138

Page 139


Ground Source Heat Pumps

Smaller YHM-A models now available, in a wider variety of sizes

A very efficient source of energy for water source heat pump systems is the Earth itself. Ground source heat pumps use the Earth's natural solar collection and heat storage capabilities as an infinite heat source/heat sink.

City Multi Zubadan Air Source Heat Pumps

At between 1.7m and 3m below the ground, the temperature changes from 17ºC in the summer to 10ºC in the winter. Deeper down however, the temperature of the ground is a constant 10ºC all year round. It is these relatively constant, dependable temperatures that can be harnessed using ground source heat pumps. The constant ground temperatures allow the heat pump to operate at optimum efficiency in both heating and cooling, as the high summer or low winter temperatures do not influence performance. Heat is extracted or rejected into the ground using water which is pumped through a network of plastic pipes.

There are two standard ground source methods available, Open Loop and Closed Loop (Bore Hole or Slinky): I

Open Loop - Large bodies of water can be utilised as a stable source of water at a relatively constant temperature. This can be either surface water or ground water. Surface water would include lakes, reservoirs, rivers and the sea.

I

I

Closed Loop Slinky - A trench is dug to a depth of between 1.7 to 3m and plastic spiral pipe is laid into the bottom.

The City Multi Zubadan heat pumps achieve an excellent heating performance even when the outdoor air temperature is as low as -25°C. These models make use of a Flash Injection Circuit, which allows the optimal amount of refrigerant to be provided to the system via the compressor through a specially designed injection port. In simple terms, the system allows a quick start up time and continuous heating; even in low ambient conditions.

The pipe is covered with sand to provide good ground to pipe contact and then the trench is backfilled with the excavated soil.

Expanded Heating Operation

Stable Heating Performance

Closed Loop Bore Hole - A series of holes are drilled down into the ground at a depth of 50 to 130m, depending

Will work effectively even when the outdoor ambient air temperature is -25°C.

Full heating capacity at -15°C, a 30% capacity improvement over the standard YJM-A model.

on geothermal conditions. Two water pipes connected via a 'u bend' are fed directly into these holes and then surrounded by a conductive grout.

J (kW)

Example of a Closed Loop Bore Hole Application:

PUHY-HP400 YSHM-A

50.0

Full heating capacity even at -15°C Capacity improvement of 30%

I

T MUL CITY M-A dard YSJ Stan Y-P400 PUH

PUHY-HP250 YHM-A

25.0

MULTI rd CITY Standa 250 YJM-A PUHY-P

10.0

-25

-20

-15

-10

3 -5 0 Outdoor temp.°C (W.B.)

Stable Operation

Quick Start-Up

Utilising the new Flash Injection Circuit the Zubadan models have reduced defrost times and can provide continuous heating for up to 250 mins.

Full heating capacity is achieved in about 20 mins, improving comfort levels.

Indoor units provide heating or cooling Ground Source Heat Pump installed inside the building, typically one per floor

J

Flow and return water loop supplies water to and from the units Bore holes absorb or reject heat from the ground

Page 140

Page 141


Features and Benefits

Fine Control of the Inverter Provides Better Efficiency and Performance Air cooled inverters use the ambient temperature to cool the inverter. For water cooled VRF (which are installed inside the building) refrigerant cooling is used to maintain accurate control of the Inverter.

High Off Coil / High Sensible Cooling Poor design or application of air conditioning systems can sometimes lead to cold draughts and uneven room temperatures. Low off coil temperatures cause dehumidifying of the air which can create dry eyes and sore throats. Mitsubishi Electric now provides a High Sensible Cooling Function specifically designed to deal with this. By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants. These high SHF’s are available throughout the range of indoor units, allowing optimum selection of units tailored to more specific design criteria.

Reduced Noise Levels: New Fan Design City Multi VRF systems led the introduction of larger single fan rotors some ten years ago, achieving substantially lower noise levels over multiple designs. Continuing the development in the areas of blade shape and weight, Mitsubishi Electric have managed to achieve even higher performance and lower noise levels. To reduce noise levels further and comply with inner city residential noise regulations, all outdoor units include Night Set-back mode. This function works by lowering the fan speed and compressor frequency proportionally with reduction in demand (44dBA for PUHY-P250YJM-A). The compressor compartment is also now sealed, further reducing noise levels.

Refrigerant Volume Checking Function New fan design

Fin Structure

Reduction of operation noise

Slits

Replace Technology

New control box design Improvement of reliability and easy maintenance

New heat exchanger design A cross-steer fin structure with additional slits helps to improve COP by up to 2% in cooling. The heating COP is also improved by 1% with the introduction of a 2.5 row heat exchanger, improving airflow and temperature valance.

Previous YHM-A

New YJM-A

Heat Exchanger

Page 142

The latest VRF Replace Multi models from Mitsubishi Electric are specifically designed for the maturing refurbishment sector, enabling the reuse of existing R22 / R407c pipework, whilst also allowing the upgrade to some of the most efficient systems available in the market. Replace Multi will clean the existing pipework during commissioning, removing any deposits and R22 mineral oil that would have ordinarily meant that new pipework would have been called for. The implications of this are significant savings on cost and time, whilst also minimising any potential disruption.

Cooling Operation Set Temperature of 14ºC

New inverter compressor Improvement of COP and partial load performance thanks to the new concentrated winding structure.

This function runs the system, measuring various temperatures and pressures throughout the system, comparing these to the values stored in the units memory from the previous service. If a leakage has occurred the system will indicate so, enabling customers to easily comply with the F-Gas regulation.

YHM-A: 3 rows

YJM-A: 2.5 rows

Environments such as gyms, laboratories etc often require the ability to cool lower than the standard comfort cooling setpoint. By selecting a dip switch on the unit, a cooling operation set temperature of 14ºC DB is possible on the floor standing and ducted models only. The indoor unit fan will be fixed at high speed during this operation.

Page 143


Effective Use of Space YGM-A

The design of City Multi outdoor units makes installation easy

YJM-A Height 1710 mm

YJM-A models have a smaller foot print requirement when compared to the YGM-A models. The width and depth have been reduced by 7% and 13% respectively, with the height being reduced by 130mm (PUHY-P250YJM-A compared to PUHY-P250YGM-A).

Width 920mm

Approximately 21% reduction in foot print

Depth 760mm

8-12hp outdoor units

(PUHY-P250)

Easily Transported The unit can easily be transported, even into inaccessible buildings. Narrow space between buildings often makes it difficult to use a crane, City Multi helps to overcome this due to its design.

The downsized outdoor unit can also be transported through an 800mm wide lift door, making access to rooftops easier.

Example of lift

Weight Reduction Weight has been reduced by approximately 33kg per module. (PUHY-P250YJM-A compared to previous YGM-A versions).

Blue Fin Treatment The anti-corrosion Blue Fin treatment of the heat exchanger is especially effective in urban environments where traffic pollutions can damage the aluminium fins, reducing the capacity and life expectancy of the unit.

33kg

YGM-A

Page 144

YJM-A

All City Multi R410A outdoor units have been treated with Blue Fin

Page 145


High Performance Heating The new High Performance Heating mode is available on all YJM-A / YJM-B models and achieves an excellent heating performance at low outdoor air temperatures, making it ideal for the UK climate.

This means the pipe itself is cheaper, easier to install and less riser space is required within the building.

Activated by dip switch on the outdoor unit, COP priority or high performance heating modes can be selected. High performance heating mode is pre-selected on all YJM-A outdoor models.

Heating Operation Range: Standard & High COP air cooled units At low ambient temperatures the guaranteed operating range in heating is minus 20ºC Operating range in cooling is from an outdoor temperature of -5ºC. Outdoor Temperature (ºC)

Back-Up & Rotate

In COP priority mode, control is reverted back to normal and the power consumption lowered. However, even at -5°C the COP is kept high. High Performance Heating Mode COP Priority Mode

down, the remaining units will perform back-up operation until the faulty unit is repaired.

the load will be balanced between the units over time, extending the life of the system.

11% capacity increase

Heating Capacity Requirement (kW)

COP (P250 High Performance Heating Mode)

37.5

6.00 5.50

32.5

5.00 27.5

4.50 4.00

22.5

3.50

17.5

3.00 12.5 7.5

2.50 -4

-2

0

2

4

6

8

10

12

2.00

Outdoor Temperature (ºC)

1.1

Ratio of Heating Capacity

Rotation - In the case of two or three modules,

The ideal application for high performance heating mode is with a heating only system, or a system sized for a heating load as this is where substantial savings can be achieved. A system is designed for full load at a fixed design temperature, for example -3°C WB as in the example below. In this example, as the ambient temperature rises, the heating load decreases and the inverter is able to ramp the heat pump down, thus increasing efficiency.

In high performance heating mode, the control strategy is altered to allow the compressor to maintain a higher frequency at lower ambient temperatures, resulting in full nominal capacity down to -5°C on many models. What this means is that a smaller outdoor unit can be installed to produce the same capacity as a larger one would if it was in COP priority mode, therefore saving on both cost and space.

Back-up - In the case of one module breaking

Seasonal Efficiency

COP

Example of a 10hp model

As R410A has a higher specific heat capacity than R22, the pipework is smaller.

Heating Capacity required (kW)

R410A Pipe Sizing

1.0

Note: This is only a representation of a PUHY-RP250 over the winter period. Actual data varies depending on individual outdoor unit.

0.9 0.8 0.7 0.6 0.5 0.4

-20

-15

-10

-5 0 Ambient Temperature

5

10

15

Note: This is only a representation. Actual data varies depending on individual outdoor unit.

Page 146

Page 147


City Multi Exceeds Current Demands for Efficiency

Enhanced Capital Allowance Scheme (ECA)

The need for energy efficiency is paramount and is determined by legislation and regulation. In 2009 the Climate Change Act was updated, putting a greater emphasis on reducing energy use and thus CO2 emissions. 2010 also saw big changes with the introduction of the CRC Energy Efficiency Scheme (formerly the Carbon Reduction Commitment), which is a mandatory emissions trading scheme. It is central to the UK’s strategy for improving energy efficiency and reducing CO2 emissions. The scheme will affect around 5000 organisations, creating a financial incentive to actively reduce their CO2 emissions across their business as a whole. In addition to these, the newly revised Part L of the building regulations outlines the need to reduce carbon emissions by 25% on aggregate over a Part L 2006 building. These regulations show the positive steps being taken towards achieving highly energy efficient, zero carbon new buildings. Mitsubishi Electric’s range of energy efficient heating, cooling, ventilation and controls products all help to comply with these regulations and schemes. To encourage efficient use of energy, the UK Government introduced the Enhanced Capital Allowance Scheme (ECA). Qualifying products on the Energy Technology Product List include heat pumps for space heating. The City Multi range has been designed to ensure businesses qualify for ECA and benefit from the utmost efficiency, both financially and environmentally.

The Key Features of the Scheme: I Under the scheme, all businesses liable for UK corporation tax are able to claim an enhanced capital allowance

Mitsubishi Electric produces a series of comprehensive CPD approved Industry Information Guides, designed to enhance the knowledge of our customers and provide a view of all the key issues facing our industry today.

All our information guides are available to download from our website: www.mitsubishielectric.co.uk/aircon

Page 148

on any qualifying expenditure (regardless of size and location of business or whether in the industrial or commercial sector). I Businesses can offset the full cost of specific technologies (such as City Multi)

against taxable profits of the period of the investment. I In order to qualify for this scheme, technology has to meet the energy saving criteria as published in the

Energy Technology Criteria List. City Multi fully meets this criteria in its drive for energy efficiency. I Only investment in new and unused plant and machinery qualify.

For further information go to www.eca.gov.uk and click on Mitsubishi Electric Air Conditioning under the heat pump category.

Page 149


A Wide Choice of Models

Y Series (12hp) PUHY-EP YJM-A 12hp

PUHY-EP300 YJM-A

The YJM-A air sourced outdoor models are modular in design and as such differing combinations of them can be connected together to create the required outdoor unit size needed for a particular application. The new YJM-A models also now make use of an extra large single module.

Y Series (16hp) PUHY-EP YSJM-A

Both the Y and R2 Series come in Standard (-P) and High COP (-EP) versions. In addition, the standard versions allow for space-saving by virtue of the combination of units having a smaller foot print than the high COP versions.

Y Series (18hp) PUHY-EP YSJM-A

The model line up Size Series Y

R2

8hp

18hp

PUHY-EP400 YSJM-A

PUHY-EP450 YSJM-A

Y Series (20hp) PUHY-EP YSJM-A

200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 1250

Model Name

16hp

20hp

PUHY-EP500 YSJM-A

PUHY-P

n

n

n

PUHY-EP

n

n

n

PURY-P

n

n

n

PURY-EP

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

Y Series (22hp) PUHY-EP YSJM-A 22hp

24hp

Y Series Heat Pump - Standard Version Y Series (8-12hp) PUHY-P YJM-A PUHY-P200 YJM-A PUHY-P250 YJM-A PUHY-P300 YJM-A

Y Series (14-16hp) PUHY-P YJM-A

Y Series (36hp) PUHY-P YSJM-A 36hp

PUHY-P900 YSJM-A

Y Series (38-40hp) PUHY-P YSJM-A

14hp

PUHY-P350 YJM-A

38hp

PUHY-P950 YSJM-A

16hp

PUHY-P400 YJM-A

40hp

PUHY-P1000 YSJM-A

Y Series (18hp) PUHY-P YJM-A 18hp

PUHY-P450 YJM-A

Y Series (20-22hp) PUHY-P YSJM-A PUHY-P500 YSJM-A

22hp

PUHY-P550 YSJM-A

Y Series (24-26hp) PUHY-P YSJM-A

Y Series (42hp) PUHY-P YSJM-A 42hp

PUHY-P1050 YSJM-A

Y Series (44hp) PUHY-P YSJM-A 44hp

PUHY-P1100 YSJM-A

Y Series (46-48hp) PUHY-P YSJM-A

24hp

PUHY-P600 YSJM-A

46hp

PUHY-P1150 YSJM-A

26hp

PUHY-P650 YSJM-A

48hp

PUHY-P1200 YSJM-A

PUHY-EP550 YSJM-A

PUHY-EP600 YSJM-A

R2 Series (8-12hp) PURY-P YJM-A 8hp 10hp 12hp

PURY-P200 YJM-A PURY-P250 YJM-A PURY-P300 YJM-A

R2 Series (14-16hp) PURY-P YJM-A

Y Series (28-30hp) PUHY-P YSJM-A PUHY-P700 YSJM-A

30hp

PUHY-P750 YSJM-A

Y Series (50hp) PUHY-P YSJM-A 50hp

PUHY-P800 YSJM-A

34hp

PUHY-P850 YSJM-A

8hp

Page 150

PUHY-EP200 YJM-A

PUHY-EP700 YSJM-A

Y Series (30hp) PUHY-EP YSJM-A 30hp

PUHY-EP750 YSJM-A

Y Series (32hp) PUHY-EP YSJM-A 32hp

PUHY-EP800 YSJM-A

10hp

PUHY-EP850 YSJM-A

Y Series (36hp) PUHY-EP YSJM-A 36hp

PUHY-EP900 YSJM-A

R2 Series (26-28hp) PURY-P YSJM-A 26hp

PURY-P650 YSJM-A

28hp

PURY-P700YSJM-A

R2 Series (30-32hp) PURY-P YSJM-A 30hp

PURY-P750 YSJM-A

32hp

PURY-P800YSJM-A

R2 Series (18hp) PURY-P YJM-A PURY-P450 YJM-A

R2 Series (18-24hp) PURY-P YSJM-A(1) 18hp 20hp 22hp 24hp

PURY-P450 YSJM-A1 PURY-P500 YSJM-A PURY-P550 YSJM-A PURY-P600 YSJM-A

R2 Series (34hp) PURY-P YSJM-A 34hp

PURY-P850 YSJM-A

R2 Series (36hp) PURY-P YSJM-A 36hp

PURY-P900 YSJM-A

R2 Series Heat Recovery - High COP Version 8hp

PURY-EP200 YJM-A

R2 Series (18-20hp) PURY-EP YSJM-A 18hp

PURY-EP450YSJM-A

20hp

PURY-EP500YSJM-A

R2 Series (22-24hp) PURY-EP YSJM-A

10hp

PURY-EP250 YJM-A

22hp

PURY-EP550YSJM-A

12hp

PURY-EP300YJM-A

24hp

PURY-EP600YSJM-A

14hp

PUHY-EP250 YJM-A

34hp

PURY-P400 YJM-A

R2 Series (14hp) PURY-EP YJM-A

Y Series (10hp) PUHY-EP YJM-A

Y Series (34hp) PUHY-EP YSJM-A

PURY-P350 YJM-A

R2 Series (10-12hp) PURY-EP YJM-A

Y Series Heat Pump - High COP Version Y Series (8hp) PUHY-EP YJM-A

28hp

16hp

PUHY-P1250 YSJM-A

Y Series (32-34hp) PUHY-P YSJM-A 32hp

Y Series (28hp) PUHY-EP YSJM-A

14hp

R2 Series (8hp) PURY-EP YJM-A

28hp

PUHY-EP650 YSJM-A

R2 Series Heat Recovery - Standard Version

18hp

20hp

26hp

10hp 12hp 14hp 16hp 18hp 20hp 22hp 24hp 26hp 28hp 30hp 32hp 34hp 36hp 38hp 40hp 42hp 44hp 46hp 48hp 50hp

Y Series (24hp) PUHY-EP YSJM-A

8hp 10hp 12hp

Y Series (26hp) PUHY-EP YSJM-A

PURY-EP350 YJM-A

R2 Series (16hp) PURY-EP YSJM-A 16hp

PURY-EP400 YSJM-A

R2 Series (26hp) PURY-EP YSJM-A 26hp

PURY-EP650YSJM-A

R2 Series (28hp) PURY-EP YSJM-A 28hp

PURY-EP700YSJM-A

Page 151


City Multi Product Range Overview Outdoor Units 140kW Cooling Capacity

11.2kW Cooling Capacity Y Series (4/5/6hp)

WY / WR2 Series

Y Series Zubadan

Y Series Replace Multi

R2 Series Replace Multi

Y / R2 Series

Y / R2 Series

Y / R2 Series

PUMY-P100-140V/YHMB

PQ(H/R)Y-P200-300YHM-A

PUHY-HP200/250YHM-A

PUHY-RP200-350YJM-B

PURY-RP200-300YJM-B

PUH/RY-P200-300YJM-A PUH/RY-EP200YJM-A

PUH/RY-P350/400YJM-A PUHY-EP250YJM-A PURY-EP250/300YJM-A

PUH/RY-P450YJM-A PUHY-EP300YJM-A PURY-EP350YJM-A

Indoor Units Model / Size

15 (1.7kW)

20 (2.2kW)

25 (2.8kW)

32 (3.6kW)

40 (4.5kW)

50 (5.6kW)

63 (7.1kW)

80 (9.0kW)

100 (11.2kW)

125 (14.0kW)

140 (16.0kW)

200 (22.4kW)

250 (28.0kW)

PLFY-P-VBM-E PLFY-P-VCM-E2 PLFY-P-VLMD-E PMFY-P-VBM-E PEFY-P-VMS1-E PEFY-P-VMA-E PEFY-P-VMH-E PCFY-P-VKM-E PKFY-P-VBM/VHM/VKM-E PFFY-P-VLRM-E PFFY-P-VLRMM-E PFFY-P-VLEM-E PFFY-P-VKM-E GUF-RD3 PWFY-P Page 152

Page 153


The energy efficient

City Multi VRF range Unique 2-pipe technology provides simultaneous heating and cooling, alongside excellent energy efficiency and corresponding EER/COP ratings. Up to 50 indoor units can be connected to a single outdoor unit, offering the sophistication, control and energy efficiency demanded today.

Contents 156

Y Series (4-6hp) Heat Pump, Outdoor Unit

200

WR2 Series (8-24hp) Heat Recovery, Water Cooled Condensing Unit

158

Y Series Standard (8-18hp) Heat Pump, Outdoor Unit

202

PFD-P-VM-E Heat Pump, Close Control System

160

Y Series Standard (20-30hp) Heat Pump, Outdoor Unit

204

PLFY-P-VBM-E 2, 3 and 4-Way Blow Ceiling Cassette Indoor Unit

162

Y Series Standard (32-36hp) Heat Pump, Outdoor Unit

206

PLFY-P-VCM-E2 600x600 4-Way Blow Ceiling Cassette Indoor Unit

164

Y Series Standard (38-44hp) Heat Pump, Outdoor Unit

208

PLFY-P-VLMD-E 2-Way Blow Ceiling Cassette Indoor Unit

166

Y Series Standard (46-50hp) Heat Pump, Outdoor Unit

210

PMFY-P-VBM-E 1-Way Blow Ceiling Cassette Indoor Unit

168

Y Series High COP (8-18hp) Heat Pump, Outdoor Unit

212

PEFY-P-VMS1-E Ultra Thin Ceiling Concealed Ducted Indoor Unit

170

Y Series High COP (20-24hp) Heat Pump, Outdoor Unit

214

PEFY-P-VMA-E Ceiling Concealed Ducted Indoor Unit

172

Y Series High COP (26-30hp) Heat Pump, Outdoor Unit

216

174

Y Series High COP (32-36hp) Heat Pump, Outdoor Unit

PEFY-P-VMH-E High Static Pressure Ceiling Concealed Ducted Indoor Unit

218

Y Series Zubadan (8-20hp) Heat Pump, Outdoor Unit

PCFY-P-VKM-E Ceiling Suspended Indoor Unit

220

Y Series Replace Multi (8-26hp) Heat Pump, Outdoor Unit

PKFY-P-VBM/VHM/VKM-E Wall Mounted Indoor Unit

222

Y Series Replace Multi (28-36hp) Heat Pump, Outdoor Unit

PFFY-P-VLRM-E Floor Standing Concealed Indoor Unit

224

WY Series (8-24hp) Heat Pump, Water Cooled Condensing Unit

PFFY-P-VLRMM-E Floor Standing Concealed Indoor Unit

226

WY Series (26-36hp) Heat Pump, Water Cooled Condensing Unit

PFFY-P-VLEM-E Floor Standing Exposed Indoor Unit

228

R2 Series Standard (8-18hp) Heat Recovery, Outdoor Unit

PFFY-P-VKM-E Floor Standing Exposed Indoor Unit

230

R2 Series Standard (18-28hp) Heat Recovery, Outdoor Unit

GUF-RD3 Lossnay Outdoor Air Processing Unit

232

R2 Series Standard (30-36hp) Heat Recovery, Outdoor Unit

PWFY-P VRF Heat Pump Boiler

234

R2 Series High COP (8-20hp) Heat Recovery, Outdoor Unit

VRF PHV DXE VRF Heat Pump Air Curtain

236

R2 Series High COP (22-28hp) Heat Recovery, Outdoor Unit

VRF PHV NT Sensible Cooling, Chilled Water Indoor Unit

238

BC Controllers

240

Water System Connection Box (WCB)

242

Air Handling Unit Controllers

243

Accessories / Optional Extras

176 178 180 182

Simple technology at its best

184 186 188 190

Many of our systems have an energy label of A, are registered on the Energy Technology List and hence qualify for 100% first year enhanced capital allowances (whole system cost and ‘reasonable’ cost of installation). For further information please go to www.eca.gov.uk

192 194 196

R2 Series Piping Restrictions

198

R2 Series Replace Multi (8-12hp) Heat Recovery, Outdoor Unit

Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB. Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB. UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. UK Conditions: Winter; indoor 21˚C DB; outdoor -1˚C WB.

Page 154

Page 155


Dimensions

Heat Pump Outdoor Unit

PUMY-P100-140VHMB/YHMB

The latest in Mitsubishi Electric R410A Y Series technology. The new City Multi models allow up to 12 indoor units to be connected to a single outdoor unit, using the standard branch/header pipework system proven in the larger models. Utilising the latest Mitsubishi Electric inverter technology, the system is fully controllable with all City Multi controllers or linked to third party BEMS.

I

A two core non-polar transmission line allows for simple installation of up to twelve indoor units now

I

Latest in inverter technology including a highly efficient DC Scroll Compressor, DC fan motor and Demand Control

I

The condensing unit is extremely slimline which allows easy location and application of the system

I

Single or three phase power supply

I

Anti-Corrosion blue and flat fin technology

Upper View

Side View

>

Front View

>

City Multi Range

Y Series (4-6hp)

>

Technical Information Y SERIES OUTDOOR UNITS 4-6hp MODEL REFERENCE

POWER INPUT (kW)

PUMY-P100VHMB PUMY-P100YHMB PUMY-P125VHMB PUMY-P125YHMB PUMY-P140VHMB PUMY-P140YHMB Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK)

COP / EER (nominal) Max no. OF CONNECTABLE INDOOR UNITS Max CONNECTABLE CAPACITY AIRFLOW (m3/min) PIPE SIZE mm(in) Gas Liquid NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE STARTING CURRENT (A) RUNNING CURRENT (A) Heating Cooling GUARANTEED OPERATING RANGE Cooling Heating FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores

12.5 12.5 16.0 16.0 18.0 18.0 11.2 11.2 14.0 14.0 15.5 15.5 10.4 10.4 13.3 13.3 14.9 14.9 10.3 10.3 12.9 12.9 14.3 14.3 3.66 3.63 4.33 4.29 5.58 5.32 3.34 3.30 4.32 4.27 5.35 5.32 3.27 3.23 3.85 3.82 4.99 4.73 2.84 2.81 3.66 3.63 4.53 4.52 3.42 / 3.35 3.44 / 3.39 3.69 / 3.24 3.73 / 3.28 3.23 / 2.90 3.38 / 2.91 8 8 10 10 12 12 50-130% OU Capacity 50-130% OU Capacity 50-130% OU Capacity 50-130% OU Capacity 50-130% OU Capacity 50-130% OU Capacity 100 100 100 100 100 100 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 49 49 50 50 51 51 129 142 129 142 129 142 950 950 950 950 950 950 330+30 330+30 330+30 330+30 330+30 330+30 1350 1350 1350 1350 1350 1350 220-240v, 50Hz 380-415v, 50Hz 220-240v, 50Hz 380-415v, 50Hz 220-240v, 50Hz 380-415v, 50Hz Single 3 Single 3 Single 3 5 5 5 5 5 5 15.5 5.32 18.3 6.29 23.6 7.8 14.1 4.84 18.3 6.26 22.7 7.8 -5ºC ~ 46ºC -5ºC ~ 46ºC -5ºC ~ 46ºC -5ºC ~ 46ºC -5ºC ~ 46ºC -5ºC ~ 46ºC -15ºC ~ 15ºC -15ºC ~ 15ºC -15ºC ~ 15ºC -15ºC ~ 15ºC -15ºC ~ 15ºC -15ºC ~ 15ºC 32 16 32 16 32 16 3 4 + earth 3 4 + earth 3 4 + earth

Y Series (4-6hp)

CAPACITY (kW)

Optional Parts PUMY-P100-140VHMB/YHMB Piping Restrictions TOTAL PIPING LENGTH FURTHEST PIPING LENGTH FURTHEST PIPING LENGTH AFTER 1st BRANCH BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

Page 156

120m max 80m max 30m max 50m max (20m max if outdoor installed below) 12m max

Model Name

Description

CMY-Y62-G-E

Branch Pipe (2 Branch)

Page 157


Dimensions

Heat Pump Outdoor Unit

PUHY-P200, 250, 300YJM-A

Improved for even higher efficiency

Side View

>

Front View

>

Upper View

>

>

Upper View

>

The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained. I I I I I I I I

I

Wrap around coil for improved energy efficiency Choice of Branch Pipe or Header Pipe feeds to indoor units Energy-saving inverter driven outdoor compressor units with very low start currents No requirement for plant rooms or bulky service shafts Weight and size reduction compared to YGM-A models Improved pipe run of 165m, with a total system pipe length of 1000m 100% inverter control High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants High Performance Heating Mode for low ambient conditions

City Multi Range

Y Series Standard (8-18hp)

PUHY-P350, 400YJM-A Side View

>

Front View

Technical Information Y SERIES STANDARD OUTDOOR UNITS 8-18hp MODEL REFERENCE

POWER INPUT (kW)

PUHY-P200YJM-A PUHY-P250YJM-A PUHY-P300YJM-A PUHY-P350YJM-A PUHY-P400YJM-A PUHY-P450YJM-A Heating (nominal)

25.0

31.5

37.5

45.0

50.0

56.0

Cooling (nominal)

22.4

28.0

33.5

40.0

45.0

50.0

High Performance Heating (UK)

25.0

31.5

35.6

42.8

47.5

50.7

COP Priority Heating (UK)

22.8

28.7

32.3

38.7

43.0

48.7

Cooling (UK)

21.3

26.6

31.5

37.6

42.3

46.0

Heating (nominal)

5.84

7.34

9.25

11.19

12.82

14.62

Cooling (nominal)

5.62

7.40

9.00

11.01

13.11

15.47

High Performance Heating (UK)

7.36

9.25

12.40

14.99

17.18

16.67

COP Priority Heating (UK)

5.78

7.27

8.97

10.85

12.44

13.30

Cooling (UK)

3.23

4.26

5.81

7.10

8.46

9.75

4.28 / 3.98

4.29 / 3.78

4.05 / 3.72

4.02 / 3.63

3.90 / 3.43

3.83 / 3.23

COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS

17

21

26

30

34

39

AIRFLOW (m3/min)

170

170

170

210

210

370

High

NOISE (dBA)

56

58

59

60

61

62

WEIGHT (kg)

190

200

215

250

250

290

Width

920

920

920

1220

1220

1750

Depth

760

760

760

760

760

760

DIMENSIONS (mm) (1650mm without legs)

Height

1710

1710

1710

1710

1710

1710

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

PHASE

3

3

3

3

3

3

STARTING CURRENT (A)

8

8

8

8

8

8

Heating

9.0

11.3

14.2

17.2

19.8

22.5

Cooling

8.6

11.4

13.9

17.0

20.2

23.9

20

20

25

32

32

40

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

ELECTRICAL SUPPLY

RUNNING CURRENT (A)

FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores

PUHY-P450YJM-A Side View

>

Front View

>

Upper View

>

Y Series Standard (8-18hp)

CAPACITY (kW)

PUHY-P200-450YJM-A Piping Restrictions TOTAL PIPING LENGTH

1000m max

FURTHEST PIPING LENGTH

165m max

FURTHEST PIPING LENGTH AFTER 1st BRANCH

40m max

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

50m max (40m max if outdoor installed below)

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

15m max

Page 158

Page 159


Dimensions

Heat Pump Outdoor Unit

PUHY-P500, 550YSJM-A Side View

Improved for even higher efficiency

>

Front View

>

The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained. I I I I I I I I

I

Wrap around coil for improved energy efficiency Choice of Branch Pipe or Header Pipe feeds to indoor units Energy-saving inverter driven outdoor compressor units with very low start currents No requirement for plant rooms or bulky service shafts Weight and size reduction compared to YGM-A models Improved pipe run of 165m, with a total system pipe length of 1000m 100% inverter control High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants High Performance Heating Mode for low ambient conditions

City Multi Range

Y Series Standard (20-30hp)

PUHY-P600, 650YSJM-A Side View

>

Front View

>

Technical Information Y SERIES STANDARD OUTDOOR UNITS 20-30hp MODEL REFERENCE

PUHY-P500YSJM-A PUHY-P550YSJM-A PUHY-P600YSJM-A PUHY-P650YSJM-A PUHY-P700YSJM-A PUHY-P750YSJM-A

Heating (nominal)

63.0

69.0

76.5

81.5

88.0

95.0

Cooling (nominal)

56.0

63.0

69.0

73.0

80.0

85.0

High Performance Heating (UK)

57.0

62.4

69.2

73.8

88.0

95.0

COP Priority Heating (UK)

54.8

60.0

66.6

70.9

76.6

82.7

Cooling (UK)

51.5

58.0

63.5

67.2

73.6

78.2

POWER INPUT (kW) Heating (nominal)

15.03

16.87

18.88

20.47

22.27

24.67

Cooling (nominal)

15.38

17.16

18.75

20.39

22.47

24.70

High Performance Heating (UK)

17.13

19.23

21.52

23.34

28.06

31.08

COP Priority Heating (UK)

13.68

15.35

17.18

18.63

20.71

22.94

Cooling (UK)

9.69

10.81

11.81

12.85

14.49

15.93

4.19 / 3.64

4.09 / 3.67

4.05 / 3.68

3.98 / 3.58

3.95 / 3.56

3.85 / 3.44

COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min)

High

43

47

50

50

50

50

170 / 170

170 / 170

210 / 170

210 / 170

210 / 210

210 / 210

NOISE (dBA)

61

61.5

62

62.5

63

63.5

WEIGHT (kg)

200 + 200

215 + 200

250 + 200

250 + 215

250 + 250

250 + 250

920 + 920

920 + 920

1220 + 920

1220 + 920

1220 + 1220

1220 + 1220

DIMENSIONS (mm)

Width Depth

760

760

760

760

760

760

Height

1710

1710

1710

1710

1710

1710

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

3

3

3

3

3

3

8/8

8/8

8/8

8/8

8/8

8/8

RUNNING CURRENT (A) Heating

23.2

26.0

29.1

31.6

34.4

38.1

Cooling

23.7

26.5

28.9

31.5

34.7

38.1

20 / 20

25 / 20

32 / 20

32 / 25

32 / 32

32 / 32

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

(1650mm without legs) ELECTRICAL SUPPLY PHASE STARTING CURRENT (A)

FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores

PUHY-P700, 750YSJM-A Side View

>

Front View

>

Y Series Standard (20-30hp)

CAPACITY (kW)

PUHY-P500-750YSJM-A Piping Restrictions TOTAL PIPING LENGTH

1000m max

FURTHEST PIPING LENGTH

165m max

FURTHEST PIPING LENGTH AFTER 1st BRANCH

40m max

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

50m max (40m max if outdoor installed below)

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

15m max

Page 160

Page 161


Dimensions

Heat Pump Outdoor Unit

PUHY-P800, 850YSJM-A

Improved for even higher efficiency

Side View

The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained. I I I I I I I I

I

>

Front View

>

Front View

>

Wrap around coil for improved energy efficiency Choice of Branch Pipe or Header Pipe feeds to indoor units Energy-saving inverter driven outdoor compressor units with very low start currents No requirement for plant rooms or bulky service shafts Weight and size reduction compared to YGM-A models Improved pipe run of 165m, with a total system pipe length of 1000m 100% inverter control High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants High Performance Heating Mode for low ambient conditions

Technical Information

City Multi Range

Y Series Standard (32-36hp)

PUHY-P900YSJM-A

MODEL REFERENCE CAPACITY (kW)

POWER INPUT (kW)

PUHY-P800YSJM-A

PUHY-P850YSJM-A

PUHY-P900YSJM-A

Heating (nominal)

100.0

108.0

113.0

Cooling (nominal)

90.0

96.0

101.0

High Performance Heating (UK)

100.0

102.6

107.4

COP Priority Heating (UK)

87.0

95.0

99.4

Cooling (UK)

82.8

88.3

92.9

Heating (nominal)

25.70

28.42

30.05

Cooling (nominal)

27.10

29.62

32.06

High Performance Heating (UK)

32.38

37.80

39.97

COP Priority Heating (UK)

23.90

26.15

27.65

Cooling (UK)

17.48

18.07

19.56

3.89 / 3.32

3.80 / 3.24

3.76 / 3.15

COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min)

High

50

50

50

370 / 210

370 / 210

370 / 370

NOISE (dBA)

64

64.5

65

WEIGHT (kg)

290 + 250

290 + 250

290 + 290 1750 + 1750

DIMENSIONS (mm) (1650mm without legs)

Width

1750 + 1220

1750 + 1220

Depth

760

760

760

Height

1710

1710

1710

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

3

3

3

8/8

8/8

8/8

Heating

39.7

43.9

46.4

Cooling

41.8

45.7

49.5

40 / 32

40 / 32

40 / 40

4 + earth

4 + earth

4 + earth

ELECTRICAL SUPPLY PHASE STARTING CURRENT (A) RUNNING CURRENT (A)

FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores

Side View

>

Y Series Standard (32-36hp)

Y SERIES STANDARD OUTDOOR UNITS 32-36hp

PUHY-P800-900YSJM-A Piping Restrictions TOTAL PIPING LENGTH

1000m max

FURTHEST PIPING LENGTH

165m max

FURTHEST PIPING LENGTH AFTER 1st BRANCH

40m max

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

50m max (40m max if outdoor installed below)

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

15m max

Page 162

Page 163


Dimensions

Heat Pump Outdoor Unit

PUHY-P950, 1000YSJM-A Side View

Improved for even higher efficiency

>

Front View

>

The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained. I I I I I I I I

I

Wrap around coil for improved energy efficiency Choice of Branch Pipe or Header Pipe feeds to indoor units Energy-saving inverter driven outdoor compressor units with very low start currents No requirement for plant rooms or bulky service shafts Weight and size reduction compared to YGM-A models Improved pipe run of 165m, with a total system pipe length of 1000m 100% inverter control High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants High Performance Heating Mode for low ambient conditions

City Multi Range

Y Series Standard (38-44hp)

PUHY-P1050YSJM-A Side View

>

Front View

>

Technical Information Y SERIES STANDARD OUTDOOR UNITS 38-44hp CAPACITY (kW)

POWER INPUT (kW)

PUHY-P950YSJM-A

PUHY-P1000YSJM-A

PUHY-P1050YSJM-A

PUHY-P1100YSJM-A

Heating (nominal)

119.5

127.0

132.0

140.0

Cooling (nominal)

108.0

113.0

118.0

124.0

High Performance Heating (UK)

113.5

120.7

125.4

133.0

COP Priority Heating (UK)

105.2

111.8

116.2

123.2

Cooling (UK)

99.4

104.0

108.6

114.1

Heating (nominal)

30.02

33.15

34.10

36.08

Cooling (nominal)

30.50

32.10

33.81

35.73

High Performance Heating (UK)

39.93

44.09

45.35

47.99

COP Priority Heating (UK)

27.62

30.50

31.37

33.19

Cooling (UK)

18.61

19.58

20.62

21.80

3.98 / 3.54

3.83 / 3.52

3.87 / 3.49

3.88 / 3.47

COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min)

High

NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm)

Width

50

50

50

50

210 / 170 / 170

210 / 170 / 170

210 / 210 / 170

210 / 210 / 210

64.5

64.5

65

65

250 + 215 + 200

250 + 215 + 215

250 + 250 + 215

250 + 250 + 250

1220 + 920 + 920

1220 + 920 + 920

1220 + 1220 + 920

1220 + 1220 + 1220

Depth

760

760

760

760

Height

1710

1710

1710

1710

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

3

3

3

3

8/8/8

8/8/8

8/8/8

8/8/8

RUNNING CURRENT (A) Heating

46.4

51.2

52.7

55.7

Cooling

47.1

49.6

52.2

55.2

32 / 25 / 20

32 / 25 / 25

32 / 32 / 25

32 / 32 / 32

4 + earth

4 + earth

4 + earth

4 + earth

(1650mm without legs) ELECTRICAL SUPPLY PHASE STARTING CURRENT (A)

FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores

PUHY-P1100YSJM-A Side View

>

Front View

>

Y Series Standard (38-44hp)

MODEL REFERENCE

PUHY-P950-1100YSJM-A Piping Restrictions TOTAL PIPING LENGTH

1000m max

FURTHEST PIPING LENGTH

165m max

FURTHEST PIPING LENGTH AFTER 1st BRANCH

40m max

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

50m max (40m max if outdoor installed below)

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

15m max

Page 164

Page 165


Dimensions

Heat Pump Outdoor Unit

PUHY-P1150, 1200YSJM-A

Improved for even higher efficiency Side View

The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained. I I I I I I I I

I

>

Front View

>

Wrap around coil for improved energy efficiency Choice of Branch Pipe or Header Pipe feeds to indoor units Energy-saving inverter driven outdoor compressor units with very low start currents No requirement for plant rooms or bulky service shafts Weight and size reduction compared to YGM-A models Improved pipe run of 165m, with a total system pipe length of 1000m 100% inverter control High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants High Performance Heating Mode for low ambient conditions

Technical Information

City Multi Range

Y Series Standard (46-50hp)

PUHY-P1250YSJM-A

Y SERIES STANDARD OUTDOOR UNITS 46-50hp CAPACITY (kW)

POWER INPUT (kW)

PUHY-P1150YSJM-A

PUHY-P1200YSJM-A

PUHY-P1250YSJM-A

Heating (nominal)

145.0

150.0

156.5

Cooling (nominal)

130.0

136.0

140.0

High Performance Heating (UK)

137.8

142.5

148.7

COP Priority Heating (UK)

127.6

132.0

137.7

Cooling (UK)

119.6

125.1

128.8

Heating (nominal)

37.27

39.26

40.86

Cooling (nominal)

38.34

40.84

42.94

High Performance Heating (UK)

49.57

52.22

54.34

COP Priority Heating (UK)

34.29

36.12

37.59

Cooling (UK)

23.39

24.91

26.19

3.89 / 3.39

3.82 / 3.33

3.83 / 3.26

COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min)

High

50

50

50

370 / 210 / 210

370 / 210 / 210

370 / 370 / 210

NOISE (dBA)

65.5

66

66

WEIGHT (kg)

290 + 250 + 250

290 + 250 + 250

290 + 290 + 250 1750 + 1750 + 1220

DIMENSIONS (mm)

Width

1750 + 1220 + 1220

1750 + 1220 + 1220

Depth

760

760

760

Height

1710

1710

1710

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

3

3

3

8/8/8

8/8/8

8/8/8

RUNNING CURRENT (A) Heating

57.6

60.6

63.1

Cooling

59.2

63.1

66.3

40 / 32 / 32

40 / 32 / 32

40 / 40 / 32

4 + earth

4 + earth

4 + earth

(1650mm without legs) ELECTRICAL SUPPLY PHASE STARTING CURRENT (A)

FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores

Side View

>

Front View

>

Y Series Standard (46-50hp)

MODEL REFERENCE

PUHY-P1150-1250YSJM-A Piping Restrictions TOTAL PIPING LENGTH

1000m max

FURTHEST PIPING LENGTH

165m max

FURTHEST PIPING LENGTH AFTER 1st BRANCH

40m max

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

50m max (40m max if outdoor installed below)

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

15m max

Page 166

Page 167


Dimensions

Heat Pump Outdoor Unit

PUHY-EP200, 250, 300YJM-A

Improved for even higher efficiency

PUHY-EP200YJM-A schematic is the same as PUHY-P200, 250, 300YJM-A on page 158 PUHY-EP250YJM-A schematic is the same as PUHY-P350, 400YJM-A on page 158 PUHY-EP300YJM-A schematic is the same as PUHY-P450YJM-A on page 158

The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained. I I I I I I I I

I

PUHY-EP400YSJM-A

Highest ever COP’s / EER’s due to new higher efficiency inverter technology and wrap around coil Choice of Branch Pipe or Header Pipe feeds to indoor units Energy-saving inverter driven outdoor compressor units with very low start currents No requirement for plant rooms or bulky service shafts Weight and size reduction compared to YGM-A models Improved pipe run of 165m, with a total system pipe length of 1000m 100% inverter control High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants High Performance Heating Mode for low ambient conditions

Side View

>

Front View

>

Front View

>

City Multi Range

Y Series High COP (8-18hp)

Technical Information Y SERIES HIGH COP OUTDOOR UNITS 8-18hp CAPACITY (kW)

POWER INPUT (kW)

PUHY-EP200YJM-A

PUHY-EP250YJM-A

PUHY-EP300YJM-A

PUHY-EP400YSJM-A

PUHY-EP450YSJM-A

Heating (nominal)

25.0

31.5

37.5

50.0

56.0

Cooling (nominal)

22.4

28.0

33.5

45.0

50.0

High Performance Heating (UK)

25.0

31.5

35.6

47.5

50.7

COP Priority Heating (UK)

22.8

28.7

32.3

43.0

48.7

Cooling (UK)

21.3

26.6

31.5

42.3

46.0

Heating (nominal)

5.54

7.15

8.37

11.41

12.90

Cooling (nominal)

5.09

6.73

8.03

10.34

11.87

High Performance Heating (UK)

6.98

9.01

11.22

15.29

14.71

COP Priority Heating (UK)

5.48

7.08

8.12

11.07

11.74

Cooling (UK) COP / EER (nominal)

2.93

3.87

5.18

6.67

7.48

4.51 / 4.40

4.40 / 4.16

4.48 / 4.17

4.38 / 4.35

4.34 / 4.21

MAX No. OF CONNECTABLE INDOOR UNITS

17

21

26

35

39

AIRFLOW (m3/min)

170

210

370

170 / 170

210 / 170

High

NOISE (dBA)

57

60

61

60

62

WEIGHT (kg)

200

250

290

200 + 200

250 + 200 1220 + 920

DIMENSIONS (mm) (1650mm without legs)

Width

920

1220

1750

920 + 920

Depth

760

760

760

760

760

Height

1710

1710

1710

1710

1710 380-415v, 50Hz

ELECTRICAL SUPPLY

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

PHASE

3

3

3

3

3

STARTING CURRENT (A)

8

8

8

8/8

8/8

RUNNING CURRENT (A) Heating

8.5

11.0

12.9

17.6

19.9

Cooling

7.8

10.4

12.4

15.9

18.3

20

20

25

20 / 20

20 / 20

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores

PUHY-EP450YSJM-A Side View

>

Y Series High COP (8-18hp)

MODEL REFERENCE

PUHY-EP200-450Y(S)JM-A Piping Restrictions TOTAL PIPING LENGTH

1000m max

FURTHEST PIPING LENGTH

165m max

FURTHEST PIPING LENGTH AFTER 1st BRANCH

40m max

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

50m max (40m max if outdoor installed below)

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

15m max

Page 168

Page 169


Dimensions

Heat Pump Outdoor Unit

PUHY-EP500YSJM-A Side View

Improved for even higher efficiency

>

Front View

>

Front View

>

Front View

>

The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained. I

Highest ever COP’s / EER’s due to new higher efficiency inverter technology and wrap around coil

I

Choice of Branch Pipe or Header Pipe feeds to indoor units

I

Energy-saving inverter driven outdoor compressor units with very low start currents

I

No requirement for plant rooms or bulky service shafts

I

Weight and size reduction compared to YGM-A models

I

Improved pipe run of 165m, with a total system pipe length of 1000m

I

100% inverter control

I

High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

I

High Performance Heating Mode for low ambient conditions

City Multi Range

Y Series High COP (20-24hp)

PUHY-EP550YSJM-A Side View

>

Technical Information Y SERIES HIGH COP OUTDOOR UNITS 20-24hp CAPACITY (kW)

POWER INPUT (kW)

PUHY-EP500YSJM-A

PUHY-EP550YSJM-A

PUHY-EP600YSJM-A

Heating (nominal)

63.0

69.0

76.5

Cooling (nominal)

56.0

63.0

69.0

High Performance Heating (UK)

57.0

62.4

69.2

COP Priority Heating (UK)

54.8

60.0

66.6

Cooling (UK)

51.5

58.0

63.5

Heating (nominal)

14.28

15.78

17.30

Cooling (nominal)

13.30

15.36

16.82

High Performance Heating (UK)

16.28

17.99

19.72

COP Priority Heating (UK)

12.99

14.36

15.74

Cooling (UK)

8.38

9.68

10.60

4.41 / 4.21

4.37 / 4.10

4.42 / 4.10

43

47

50 370 / 370

COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min)

High

370 / 170

370 / 210

NOISE (dBA)

62.5

63.5

64

WEIGHT (kg)

290 + 200

290 + 250

290 + 290 1750 + 1750

DIMENSIONS (mm)

Width

1750 + 920

1750 + 1220

Depth

760

760

760

Height

1710

1710

1710

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

3

3

3

8/8

8/8

8/8

RUNNING CURRENT (A) Heating

22.0

24.3

26.7

Cooling

20.5

23.7

26.0

25 / 20

25 / 20

25 / 25

4 + earth

4 + earth

4 + earth

(1650mm without legs) ELECTRICAL SUPPLY PHASE STARTING CURRENT (A)

FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores

PUHY-EP600YSJM-A Side View

>

Y Series High COP (20-24hp)

MODEL REFERENCE

PUHY-EP500-600YSJM-A Piping Restrictions TOTAL PIPING LENGTH

1000m max

FURTHEST PIPING LENGTH

165m max

FURTHEST PIPING LENGTH AFTER 1st BRANCH

40m max

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

50m max (40m max if outdoor installed below)

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

15m max

Page 170

Page 171


Dimensions

Heat Pump Outdoor Unit

PUHY-EP650YSJM-A Side View

Improved for even higher efficiency

>

Front View

>

The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained. Highest ever COP’s / EER’s due to new higher efficiency inverter technology and wrap around coil I Choice of Branch Pipe or Header Pipe feeds to indoor units I Energy-saving inverter driven outdoor compressor units with very low start currents I No requirement for plant rooms or bulky service shafts I Weight and size reduction compared to YGM-A models I Improved pipe run of 165m, with a total system pipe length of 1000m I 100% inverter control I High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants I High Performance Heating Mode for low ambient conditions I

City Multi Range

Y Series High COP (26-30hp)

PUHY-EP700YSJM-A Side View

>

Front View

>

Technical Information Y SERIES HIGH COP OUTDOOR UNITS 26-30hp CAPACITY (kW)

POWER INPUT (kW)

PUHY-EP650YSJM-A

PUHY-EP700YSJM-A

PUHY-EP750YSJM-A

Heating (nominal)

81.5

88.0

95.0

Cooling (nominal)

73.0

80.0

85.0

High Performance Heating (UK)

73.8

88.0

95.0

COP Priority Heating (UK)

70.9

76.6

82.7

Cooling (UK)

67.2

73.6

78.2

Heating (nominal)

18.56

20.00

21.93

Cooling (nominal)

17.46

19.13

20.43

High Performance Heating (UK)

21.16

25.20

27.63

COP Priority Heating (UK)

16.89

18.60

20.39

Cooling (UK)

11.00

12.34

13.18

4.39 / 4.18

4.40 / 4.18

4.33 / 4.16

50

50

50

COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min)

High

210 / 170 / 170

370 / 170 / 170

370 / 210 / 170

NOISE (dBA)

63

63.5

64.5

WEIGHT (kg)

250 + 200 + 200

290 + 200 + 200

290 + 250 + 200 1750 + 1220 + 920

DIMENSIONS (mm) (1650mm without legs)

Width

1220 + 920 + 920

1750 + 920 + 920

Depth

760

760

760

Height

1710

1710

1710

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

3

3

3

8/8/8

8/8/8

8/8/8

Heating

28.6

30.9

33.8

Cooling

26.9

29.5

31.5

20 / 20 / 20

25 / 20 / 20

25 / 20 / 20

4 + earth

4 + earth

4 + earth

ELECTRICAL SUPPLY PHASE STARTING CURRENT (A) RUNNING CURRENT (A)

FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores

PUHY-EP750YSJM-A Side View

>

Front View

>

Y Series High COP (26-30hp)

MODEL REFERENCE

PUHY-EP650-750YSJM-A Piping Restrictions TOTAL PIPING LENGTH

1000m max

FURTHEST PIPING LENGTH

165m max

FURTHEST PIPING LENGTH AFTER 1st BRANCH

40m max

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

50m max (40m max if outdoor installed below)

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

15m max

Page 172

Page 173


Dimensions

Heat Pump Outdoor Unit

PUHY-EP800YSJM-A

Improved for even higher efficiency

Side View

>

Front View

>

The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained. Highest ever COP’s / EER’s due to new higher efficiency inverter technology and wrap around coil I Choice of Branch Pipe or Header Pipe feeds to indoor units I Energy-saving inverter driven outdoor compressor units with very low start currents I No requirement for plant rooms or bulky service shafts I Weight and size reduction compared to YGM-A models I Improved pipe run of 165m, with a total system pipe length of 1000m I 100% inverter control I High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants I High Performance Heating Mode for low ambient conditions I

City Multi Range

Y Series High COP (32-36hp)

PUHY-EP850YSJM-A Side View

>

Front View

>

Technical Information Y SERIES HIGH COP OUTDOOR UNITS 32-36hp CAPACITY (kW)

POWER INPUT (kW)

PUHY-EP800YSJM-A

PUHY-EP850YSJM-A

PUHY-EP900YSJM-A

Heating (nominal)

100.0

108.0

113.0

Cooling (nominal)

90.0

96.0

101.0

High Performance Heating (UK)

100.0

102.6

107.4

COP Priority Heating (UK)

87.0

95.0

99.4

Cooling (UK)

82.8

88.3

92.9

Heating (nominal)

22.77

24.65

25.50

Cooling (nominal)

21.63

23.58

24.81

High Performance Heating (UK)

28.69

32.78

33.92

COP Priority Heating (UK)

21.18

22.68

23.46

Cooling (UK)

13.95

14.38

15.13

4.39 / 4.16

4.38 / 4.07

4.43 / 4.07

COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min)

High

50

50

50

370 / 370 / 170

370 / 370 / 210

370 / 370 / 370

NOISE (dBA)

65

65.5

66

WEIGHT (kg)

290 + 290 + 200

290 + 290 + 250

290 + 290 + 290

Width

1750 + 1750 + 920

1750 + 1750 + 1220

1750 +1750 + 1750

Depth

760

760

760

DIMENSIONS (mm) (1650mm without legs)

Height

ELECTRICAL SUPPLY

1710

1710

380-415v, 50Hz

380-415v, 50Hz

3

3

3

8/8/8

8/8/8

8/8/8

Heating

35.1

38.1

39.4

Cooling

33.4

36.4

38.3

25 / 25 / 20

25 / 25 / 20

25 / 25 / 25

4 + earth

4 + earth

4 + earth

PHASE STARTING CURRENT (A) RUNNING CURRENT (A)

1710 380-415v, 50Hz

FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores

PUHY-EP900YSJM-A Side View

>

Front View

Y Series High COP (32-36hp)

MODEL REFERENCE

>

PUHY-EP800-900YSJM-A Piping Restrictions TOTAL PIPING LENGTH

1000m max

FURTHEST PIPING LENGTH

165m max

FURTHEST PIPING LENGTH AFTER 1st BRANCH

40m max

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

50m max (40m max if outdoor installed below)

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

15m max

Page 174

Page 175


Dimensions

Heat Pump Outdoor Unit

PUHY-HP200, 250YHM-A

>

Upper View

Zubadan sets a new standard in performance The new City Multi Zubadan heat pumps achieve an excellent heating performance even when the outdoor air temperature is as low as -25ºC. I

Stable Heating Performance - Full heating capacity at -15°C - a 40% capacity improvement over the standard YJM-A model

I

Expanded Heating Operation - Will work effectively even when the outdoor ambient air temperature is -25°C

I

Stable Operation - Utilising the new Flash Injection Circuit the Zubadan models have reduced defrost times and can provide continuous heating for up to 250 mins

I

Quick Start-Up - Full heating capacity is achieved in about 20 mins, improving comfort levels

I

Energy-saving inverter driven outdoor compressor units with very low start currents

I

100% inverter control

I

High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

Side View

>

Front View

>

City Multi Range

Y Series Zubadan (8-20hp)

Technical Information MODEL REFERENCE CAPACITY (kW)

POWER INPUT (kW)

PUHY-HP200YHM-A

PUHY-HP250YHM-A

PUHY-HP400YSHM-A

PUHY-HP500YSHM-A

Heating (nominal)

25.0

31.5

50.0

63.0

Cooling (nominal)

22.4

28.0

45.0

56.0

Heating (UK)

28.0

35.3

56.0

70.6

Cooling (UK)

19.9

24.9

40.1

49.8

Heating (nominal)

6.52

8.94

13.35

18.04

Cooling (nominal)

6.40

9.06

12.86

18.16

Heating (UK)

11.02

15.11

22.56

30.49

Cooling (UK)

4.99

7.07

10.03

14.16

3.83 / 3.50

3.52 / 3.09

3.74 / 3.49

3.49 / 3.08

COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS

17

21

34

43

AIRFLOW (m3/min)

225

225

225 / 225

225 / 225

56

57

59

60

High

NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) (1650mm without legs)

220

220

220 + 220

220 + 220

Width

920

920

920 + 920

920 + 920

Depth

760

760

760

760

Height

1710

1710

1710

1710 380-415v, 50Hz

ELECTRICAL SUPPLY

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

PHASE

3

3

3

3

STARTING CURRENT (A)

8

8

8/8

8/8

Heating

10.0

13.8

20.6

27.8

Cooling

9.8

14.0

19.8

28.0

32

32

32 / 32

32 / 32

RUNNING CURRENT (A)

FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores OPERATING RANGE (Outdoor temp ºC) Heating

4 + earth

4 + earth

4 + earth

4 + earth

-25 - 15.5ºC

-25 - 15.5ºC

-25 - 15.5ºC

-25 - 15.5ºC

PUHY-HP400, 500YSHM-A

Side View

>

Front View

Upper View

>

> Y Series Zubadan (8-20hp)

Y SERIES ZUBADAN OUTDOOR UNITS 8-20hp

PUHY-HP200-500Y(S)HM-A Piping Restrictions TOTAL PIPING LENGTH

300m max

FURTHEST PIPING LENGTH

150m max

FURTHEST PIPING LENGTH AFTER 1st BRANCH

40m max

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

50m max (40m max if outdoor installed below)

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

15m max

Page 176

Page 177


Dimensions

Heat Pump Outdoor Unit

PUHY-RP200, 250, 300, 350YJM-B

Upper View

>

Enables the replacement of VRF systems, whilst utilising existing R22 / R407c pipework. The latest VRF Replace Multi from Mitsubishi Electric is specifically designed for the maturing refurbishment sector, enabling the reuse of existing R22 / R407c pipework, whilst also allowing the upgrade to some of the most efficient systems available in the market. Replace Multi will clean the existing pipework during commissioning, removing any deposits and R22 mineral oil that would have ordinarily meant that new pipework would have been called for. The implications of this are significant savings on cost and time, whilst also minimising any potential disruption.

Side View

>

Front View

>

n Efficient use of existing resources - refrigerant piping, control and power wiring and less waste materials n Increased energy efficiency - up to 105% more efficient than an old Mitsubishi Electric R22 system (size 200) n Reduced installation costs of up to 55% n Reduced CO2 emissions and running cost savings of up to 45% n Reduced installation time with minimised disruption n Ability to replace many non Mitsubishi Electric systems n High Performance Heating Mode for low ambient conditions

City Multi Range

Y Series Replace Multi (8-26hp)

Technical Information Y SERIES REPLACE MULTI OUTDOOR UNITS 8-26hp

CAPACITY (kW)

Heating (nominal)

25.0

31.5

37.5

45.0

50.0

56.0

63.0

69.0

76.5

81.5

Cooling (nominal)

22.4

28.0

33.5

40.0

45.0

50.0

56.0

63.0

69.0

73.0

High Performance Heating (UK)

25.0

31.5

36.0

43.2

48.0

53.8

60.5

66.2

73.4

78.2

COP Priority Heating (UK)

22.8

28.7

32.6

39.2

43.5

48.7

54.8

60.0

66.6

70.9

Cooling (UK)

19.9

24.9

31.5

37.6

42.3

46.0

51.5

58.0

63.5

67.2

POWER INPUT (kW) Heating (nominal)

5.69

7.22

9.42

12.60

11.38

12.81

14.44

16.62

19.22

21.73

Cooling (nominal)

5.68

7.62

8.98

11.79

11.87

13.77

15.68

17.50

18.59

21.09

High Performance Heating (UK)

7.34

9.31

12.43

16.63

14.57

16.40

18.48

21.27

24.60

27.81

COP Priority Heating (UK)

5.63

7.15

9.14

12.22

11.04

11.66

13.14

15.12

17.49

19.77

Cooling (UK)

4.43

5.94

7.36

9.67

9.73

9.64

10.98

12.25

13.01

14.76

4.39 / 3.94

4.36 / 3.67

3.98 / 3.73

3.57 / 3.39

4.39 / 3.79

4.37 / 3.63

4.36 / 3.57

4.15 / 3.60

3.98 / 3.71

3.75 / 3.46

COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS

17

21

26

30

32

32

32

32

32

32

AIRFLOW (m3/min)

185

185

185

185

185 / 185

185 / 185

185 / 185

185 / 185

185 / 185

185 / 185

High

NOISE (dBA)

56

57

59

60

59

59.5

60

61

62

62.5

WEIGHT (kg)

230

255

255

255

230 + 230

255 + 230

255 + 255

255 + 255

255 + 255

255 + 255 920 + 920

DIMENSIONS (mm) (1650mm without legs)

Width

920

920

920

920

920 + 920

920 + 920

920 + 920

920 + 920

920 + 920

Depth

760

760

760

760

760

760

760

760

760

760

Height

1710

1710

1710

1710

1710

1710

1710

1710

1710

1710

ELECTRICAL SUPPLY

Upper View

Side View

>

Front View

>

>

380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz

PHASE

3

3

3

3

3

3

3

3

3

3

STARTING CURRENT (A)

8

8

8

8

8+8

8+8

8+8

8+8

8+8

8+8

Heating

8.7

12.1

15.2

20.2

17.5

20.7

24.2

27.3

31.1

35.0

Cooling

8.7

12.7

14.4

18.9

18.3

22.2

26.2

28.7

30.8

34.0

20

20

25

32

20 + 20

20 + 20

20 + 20

25 + 20

25 + 25

32 + 25

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

RUNNING CURRENT (A)

PUHY-RP400, 450, 500, 550, 600, 650YSJM-B

Y Series Replace Multi (8-26hp)

PUHYPUHYPUHYPUHYPUHYPUHYPUHYPUHYPUHYPUHYRP200YJM-B RP250YJM-B RP300YJM-B RP350YJM-B RP400YSJM-B RP450YSJM-B RP500YSJM-B RP550YSJM-B RP600YSJM-B RP650YSJM-B

MODEL REFERENCE

FUSE RATING (MCB sizes BS EN 60947-2) - HRC (A) MAINS CABLE No. Cores

PUHY-RP200-650Y(S)JM-B Piping Restrictions TOTAL PIPING LENGTH FURTHEST PIPING LENGTH FURTHEST PIPING LENGTH AFTER 1st BRANCH

300m max (250m for size 600-650) 120m max 40m max

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

50m max (40m max if outdoor installed below)

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

15m max

Page 178

Page 179


Dimensions

Heat Pump Outdoor Unit

PUHY-RP700, 750, 800, 850, 900YSJM-B

Enables the replacement of VRF systems, whilst utilising existing R22 / R407c pipework. Upper View

The latest VRF Replace Multi from Mitsubishi Electric is specifically designed for the maturing refurbishment sector, enabling the reuse of existing R22 / R407c pipework, whilst also allowing the upgrade to some of the most efficient systems available in the market.

>

Replace Multi will clean the existing pipework during commissioning, removing any deposits and R22 mineral oil that would have ordinarily meant that new pipework would have been called for. The implications of this are significant savings on cost and time, whilst also minimising any potential disruption. I

Tried and tested technology that’s been employed for over 5 years

I

Efficient use of existing resources - refrigerant piping, control and power wiring and less waste materials

I

Reduced installation costs of up to 55%

I

Reduced CO2 emissions and increased energy efficiency resulting in running cost savings of up to 45%

I

Reduced installation time with minimised disruption

I

Ability to replace many non Mitsubishi Electric systems

I

High Performance Heating Mode for low ambient conditions

Side View

>

Front View

>

City Multi Range

Y Series Replace Multi (28-36hp)

Technical Information

MODEL REFERENCE

PUHY-RP700YSJM-B

PUHY-RP750YSJM-B

PUHY-RP800YSJM-B

PUHY-RP850YSJM-B

PUHY-RP900YSJM-B

Heating (nominal)

88.0

95.0

100.0

108.0

113.0

Cooling (nominal)

80.0

85.0

90.0

96.0

101.0

High Performance Heating (UK)

84.5

91.2

96.0

103.7

108.5

COP Priority Heating (UK)

76.6

82.7

87.0

94.0

98.3

Cooling (UK)

73.6

78.2

82.8

88.3

92.9

POWER INPUT (kW) Heating (nominal)

20.13

21.78

23.75

26.47

28.39

Cooling (nominal)

22.22

24.14

25.49

27.11

28.29

High Performance Heating (UK)

26.57

28.75

31.35

34.15

36.62

COP Priority Heating (UK)

18.72

20.26

22.09

24.09

25.83

Cooling (UK)

18.66

20.28

21.41

22.77

23.76

4.37 / 3.60

4.36 / 3.52

4.21 / 3.53

4.08 / 3.54

3.98 / 3.57

CAPACITY (kW)

COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min)

High

32

32

32

32

32

185 / 185 / 185

185 / 185 / 185

185 / 185 / 185

185 / 185 / 185

185 / 185 / 185

NOISE (dBA)

61.5

62

62.5

63.5

64

WEIGHT (kg)

255 + 255 + 230

255 + 255 + 255

255 + 255 + 255

255 + 255 + 255

255 + 255 + 255 920 + 920 + 920

DIMENSIONS (mm) (1650mm without legs)

Width

920 + 920 + 920

920 + 920 + 920

920 + 920 + 920

920 + 920 + 920

Depth

760

760

760

760

760

Height

1710

1710

1710

1710

1710

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

3

3

3

3

3

8+8+8

8+8+8

8+8+8

8+8+8

8+8+8

Heating

33.0

36.5

39.3

43.2

45.9

Cooling

36.4

39.7

42.0

44.1

45.7

20 + 20 + 20

20 + 20 + 20

25 + 20 + 20

25 + 25 + 20

25 + 25 + 25

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

ELECTRICAL SUPPLY PHASE STARTING CURRENT (A) RUNNING CURRENT (A)

FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores

Y Series Replace Multi (28-36hp)

Y SERIES REPLACE MULTI OUTDOOR UNITS 28-36hp

PUHY-RP700-900YSJM-B Piping Restrictions TOTAL PIPING LENGTH

250m max

FURTHEST PIPING LENGTH

100m max

FURTHEST PIPING LENGTH AFTER 1st BRANCH

40m max

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

50m max (40m max if outdoor installed below)

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

15m max

Page 180

Page 181


Dimensions

Heat Pump, Water Cooled Condensing Unit

PQHY-P200, 250, 300YHM-A

The WY Series has all the benefits of the Y Series using water cooled condensing units. It is also able to produce heat recovery via the water circuit between heat source units, making for a very economical system. Like the YJM-A air source versions, the water cooled units now benefit from a modular design approach. A twinning kit is required for double combinations. I

High COPs possible thanks to increased efficiency and careful control of the system, allowing the largest operational water circuit temperature band ever

I

40% height reduction compared to previous YGM-A models

I

Combining WY with waste heat energy provides unique application solutions

I

Up to 50 indoor units can now be connected to each condensing unit

I

Single inverter compressor

I

Improved pipe run of 165m with a total system pipe length of up to 500m

I

High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

I

Able to operate with closed loop ground source water temperatures, bore hole and slinky applications are now possible

I

Easy maintenance - front panel access to all PCB’s

I

Condensing units must be situated indoors

Upper View

Front View

>

>

Right Side View

>

City Multi Range

WY Series (8-24hp)

Technical Information

PQHY-P400, 450, 500, 550, 600YSHM-A

WY SERIES HEAT SOURCE UNITS - 8-24hp MODEL REFERENCE

POWER INPUT (kW)

PQHY-P200YHM-A PQHY-P250YHM-A PQHY-P300YHM-A PQHY-P400YSHM-A PQHY-P450YSHM-A PQHY-P500YSHM-A PQHY-P550YSHM-A PQHY-P600YSHM-A Heating (nominal)

25.0

31.5

37.5

50.0

56.0

63.0

69.0

Cooling (nominal)

22.4

28.0

33.5

45.0

50.0

56.0

63.0

69.0

Heating (nominal)

4.12

5.80

8.15

8.65

10.42

12.06

14.65

17.12

Cooling (nominal) COP / EER (nominal)

76.5

3.92

5.45

7.36

8.25

9.84

11.45

13.46

15.48

6.06 / 5.71

5.43 / 5.13

4.60 / 4.55

5.78 / 5.45

5.37 / 5.08

5.22 / 4.89

4.70 / 4.68

4.46 / 4.45 50

MAX No. OF CONNECTABLE INDOOR UNITS

17

21

26

34

39

43

47

NOISE (dBA)

47

49

50

50

51

52

52.5

53

WEIGHT (kg)

195

195

195

195 + 195

195 + 195

195 + 195

195 + 195

195 + 195

Width

880

880

880

880 + 880

880 + 880

880 + 880

880 + 880

880 + 880

Depth

550

550

550

550

550

550

550

550

Height

1160

1160

1160

1160

1160

1160

1160

1160

DIMENSIONS (mm)

(1100 without legs) ELECTRICAL SUPPLY

380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz

380-415v, 50Hz

3

3

3

3

3

3

3

3

STARTING CURRENT (A)

8

8

8

8/8

8/8

8/8

8/8

8/8

Heating

6.3

8.9

12.5

13.3

16.1

18.6

22.6

26.4

Cooling

6.0

8.4

11.3

12.7

15.2

17.6

20.8

23.9

20

20

20

20 / 20

20 / 20

20 / 20

20 / 20

20 / 20

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores

>

Front View

>

380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz

PHASE

RUNNING CURRENT (A)

Left Side View

WY Series (8-24hp)

CAPACITY (kW)

PQHY-P200-600Y(S)HM-A Piping Restrictions TOTAL PIPING LENGTH FURTHEST PIPING LENGTH FURTHEST PIPING LENGTH AFTER 1st BRANCH

300m max for sizes 200-300 / 500m max for sizes 400-600 165m max 40m max

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

50m max (40m max if outdoor installed below)

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

15m max

Page 182

Page 183


Dimensions

Heat Pump, Water Cooled Condensing Unit

PQHY-P650, 700, 750, 800, 850, 900YSHM-A

The WY Series has all the benefits of the Y Series using water cooled condensing units. It is also able to produce heat recovery via the water circuit between heat source units, making for a very economical system. Like the YJM-A air source versions, the water cooled units now benefit from a modular design approach. A twinning kit is required. I

High COPs possible thanks to increased efficiency and careful control of the system, allowing the largest operational water circuit temperature band ever

I

40% height reduction compared to previous YGM-A models

I

Combining WY with waste heat energy provides unique application solutions

I

Up to 50 indoor units can now be connected to each condensing unit

I

Single inverter compressor

I

Improved pipe run of 165m with a total system pipe length of up to 500m

I

High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

I

Able to operate with closed loop ground source water temperatures, bore hole and slinky applications are now possible

I

Easy maintenance front panel access to all PCB’s

I

Condensing units must be situated indoors

Upper View

Left Side View

>

Front View

>

>

City Multi Range

WY Series (26-36hp)

Technical Information MODEL REFERENCE CAPACITY (kW)

POWER INPUT (kW)

PQHY-P650YSHM-A

PQHY-P700YSHM-A

PQHY-P750YSHM-A

PQHY-P800YSHM-A

PQHY-P850YSHM-A

PQHY-P900YSHM-A

Heating (nominal)

81.5

88.0

95.0

100.0

108.0

113.0

Cooling (nominal)

73.0

80.0

85.0

90.0

96.0

101.0

Heating (nominal)

14.74

16.51

18.27

20.74

23.21

25.67

Cooling (nominal)

13.96

15.58

17.19

19.18

21.20

23.22

5.52 / 5.22

5.33 / 5.13

5.19 / 4.94

4.82 / 4.69

4.65 / 4.52

4.40 / 4.34 50

COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS

50

50

50

50

50

NOISE (dBA)

53

53.5

54

54

54.5

55

WEIGHT (kg)

195 + 195 + 195

195 + 195 + 195

195 + 195 + 195

195 + 195 + 195

195 + 195 + 195

195 + 195 + 195

Width

880 + 880 + 880

880 + 880 + 880

880 + 880 + 880

880 + 880 + 880

880 + 880 + 880

880 + 880 + 880

Depth

550

550

550

550

550

550

Height

1160

1160

1160

1160

1160

1160

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

3

3

3

3

3

3

8/8/8

8/8/8

8/8/8

8/8/8

8/8/8

8/8/8

Heating

22.7

25.5

28.2

32.0

35.8

39.6

Cooling

21.5

24.0

26.5

29.6

32.7

35.8

20 / 20 / 20

20 / 20 / 20

20 / 20 / 20

20 / 20 / 20

20 / 20 / 20

20 / 20 / 20

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

DIMENSIONS (mm)

(1100 without legs) ELECTRICAL SUPPLY PHASE STARTING CURRENT (A) RUNNING CURRENT (A)

FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores

WY Series (26-36hp)

WY SERIES HEAT SOURCE UNITS - 26-36hp

PQHY-P650-900YSHM-A Piping Restrictions TOTAL PIPING LENGTH

500m max

FURTHEST PIPING LENGTH

165m max

FURTHEST PIPING LENGTH AFTER 1st BRANCH

40m max

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

50m max (40m max if outdoor installed below)

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

15m max

Page 184

Page 185


Dimensions

Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit

PURY-P200, 250, 300YJM-A

Improved for even higher efficiency

Side View

>

Front View

>

Upper View

>

>

Upper View

>

Upper View

>

Throughout the year, many buildings require cooling in some areas and heating in others - even in adjacent rooms. The outstanding City Multi R2 system meets this requirement by distributing surplus heat from cooling operations (and vice versa) to rooms where it is needed. This efficiency can result in energy savings of up to 30% over conventional systems. I

New higher efficiency inverter technology, with low start currents and wrap around coil for added efficiency

I

Up to 45 indoor units connected to each outdoor unit

I

Easy to install unique 2-pipe technology means minimal disruption, quicker installation and less connections than 3 pipe equivalents

I

Weight and size reduction compared to YGM-A models

I

Improved pipe run of 165m with a total system pipe length of up to 600m

I

100% inverter control

I

High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

I

High Performance Heating Mode for low ambient conditions

City Multi Range

R2 Series Standard (8-18hp)

PURY-P350, 400YJM-A Side View

>

Front View

Technical Information R2 SERIES STANDARD OUTDOOR UNITS 8-18hp MODEL REFERENCE

PURY-P200YJM-A PURY-P250YJM-A PURY-P300YJM-A PURY-P350YJM-A PURY-P400YJM-A PURY-P450YJM-A 25.0

31.5

37.5

45.0

50.0

56.0

Cooling (nominal)

22.4

28.0

33.5

40.0

45.0

50.0

High Performance Heating (UK)

25.0

31.5

35.6

42.8

47.5

50.7

COP Priority Heating (UK)

22.8

28.7

32.3

38.7

43.0

48.7

Cooling (UK)

21.3

26.6

31.5

37.6

42.3

46.0

POWER INPUT (kW) Heating (nominal)

5.69

7.32

8.78

10.89

12.75

14.58

Cooling (nominal)

5.18

7.05

8.67

11.33

13.55

14.49

High Performance Heating (UK)

7.17

9.22

11.77

14.59

17.09

16.62

COP Priority Heating (UK)

5.63

7.25

8.52

10.56

12.37

13.27

Cooling (UK) COP / EER (nominal)

2.98

4.05

5.59

7.31

8.74

9.13

4.39 / 4.32

4.30 / 3.97

4.27 / 3.86

4.13 / 3.53

3.92 / 3.32

3.84 / 3.45

MAX No. OF CONNECTABLE INDOOR UNITS

20

25

30

35

40

45

AIRFLOW (m3/min)

185

185

185

225

225

360

High

NOISE (dBA)

56

57

59

60

61

62

WEIGHT (kg)

240

240

245

270

270

320 1750

DIMENSIONS (mm) (1650mm without legs)

Width

920

920

920

1220

1220

Depth

760

760

760

760

760

760

Height

1710

1710

1710

1710

1710

1710

ELECTRICAL SUPPLY

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

PHASE

3

3

3

3

3

3

STARTING CURRENT (A)

8

8

8

8

8

8

Heating

8.7

11.3

13.5

16.8

19.7

22.5

Cooling

8.0

10.8

13.4

17.5

20.9

22.3

20

20

25

32

40

40

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

RUNNING CURRENT (A)

FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores

PURY-P450YJM-A Side View

>

Front View

>

R2 Series Standard (8-18hp)

Heating (nominal)

CAPACITY (kW)

Note: For piping restrictions for PURY-P200-450YJM-A please see page 196 Page 186

Page 187


Dimensions

Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit

PURY-P450YSJM-A1 / PURY-P500, 550, 600YSJM-A

Improved for even higher efficiency Side View

Throughout the year, many buildings require cooling in some areas and heating in others - even in adjacent rooms. The outstanding City Multi R2 system meets this requirement by distributing surplus heat from cooling operations (and vice versa) to rooms where it is needed. This efficiency can result in energy savings of up to 30% over conventional systems. I

New higher efficiency inverter technology, with low start currents and wrap around coil for added efficiency

I

Up to 50 indoor units connected to each outdoor unit

I

Easy to install unique 2-pipe technology means minimal disruption, quicker installation and less connections than 3 pipe equivalents

I

Weight and size reduction compared to YGM-A models

I

Improved pipe run of 165m with a total system pipe length of up to 950m

I

100% inverter control

I

High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

I

High Performance Heating Mode for low ambient conditions

>

Front View

>

City Multi Range

R2 Series Standard (18-28hp)

PURY-P650, 700YSJM-A

Technical Information

Side View

>

Front View

>

R2 SERIES STANDARD OUTDOOR UNITS 18-28hp MODEL REFERENCE

56.0

63.0

69.0

76.5

81.5

88.0

Cooling (nominal)

50.0

56.0

63.0

69.0

73.0

80.0

High Performance Heating (UK)

50.7

57.0

62.4

69.2

73.8

88.0

COP Priority Heating (UK)

48.7

54.8

60.0

66.6

70.9

76.6

Cooling (UK)

46.0

51.5

58.0

63.5

67.2

73.6

POWER INPUT (kW) Heating (nominal)

13.30

15.10

16.95

19.07

20.47

22.33

Cooling (nominal)

12.50

14.85

17.30

19.65

21.53

23.95

High Performance Heating (UK)

15.16

17.21

19.32

21.74

23.34

28.14

COP Priority Heating (UK)

12.10

13.74

15.42

17.35

18.63

20.77

Cooling (UK)

7.88

9.36

10.90

12.38

13.56

15.45

4.21 / 4.00

4.17 / 3.77

4.07 / 3.64

4.01 / 3.51

3.98 / 3.39

3.94 / 3.34

COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min)

High

45

50

50

50

50

50

185 / 185

185 / 185

185 / 185

185 / 185

225 / 185

225 / 185

NOISE (dBA)

59.5

60

61

62

62.5

63

WEIGHT (kg)

240 + 240

240 + 240

245 + 240

245 + 245

270 + 245

270 + 245 1220 + 920

Width

920 + 920

920 + 920

920 + 920

920 + 920

1220 + 920

Depth

760

760

760

760

760

760

Height

1710

1710

1710

1710

1710

1710

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

3

3

3

3

3

3

8/8

8/8

8/8

8/8

8/8

8/8

RUNNING CURRENT (A) Heating

20.5

23.3

26.2

29.4

31.6

34.5

Cooling

19.3

22.9

26.7

30.3

33.2

37.0

20 / 20

20 / 20

25 / 20

25 / 25

32 / 25

40 / 25

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

DIMENSIONS (mm) (1650mm without legs) ELECTRICAL SUPPLY PHASE STARTING CURRENT (A)

FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores

R2 Series Standard (18-28hp)

PURY-P450YSJM-A1 PURY-P500YSJM-A PURY-P550YSJM-A PURY-P600YSJM-A PURY-P650YSJM-A PURY-P700YSJM-A

Heating (nominal)

CAPACITY (kW)

Note: For piping restrictions for PURY-P450-700YSJM-A(1) please see page 196 Page 188

Page 189


Dimensions

Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit

PURY-P750, 800YSJM-A Side View

Improved for even higher efficiency

>

Front View

>

Front View

>

Front View

>

Throughout the year, many buildings require cooling in some areas and heating in others - even in adjacent rooms. The outstanding City Multi R2 system meets this requirement by distributing surplus heat from cooling operations (and vice versa) to rooms where it is needed. This efficiency can result in energy savings of up to 30% over conventional systems. I

New higher efficiency inverter technology, with low start currents and wrap around coil for added efficiency

I

Up to 50 indoor units connected to each outdoor unit

I

Easy to install unique 2-pipe technology means minimal disruption, quicker installation and less connections than 3 pipe equivalents

I

Weight and size reduction compared to YGM-A models

I

Improved pipe run of 165m with a total system pipe length of up to 950m

I

100% inverter control

I

High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

I

High Performance Heating Mode for low ambient conditions

City Multi Range

R2 Series Standard (30-36hp)

PURY-P850YSJM-A Side View

>

Technical Information R2 SERIES STANDARD OUTDOOR UNITS 30-36hp PURY-P750YSJM-A

PURY-P800YSJM-A

PURY-P850YSJM-A

PURY-P900YSJM-A

Heating (nominal)

95.0

100.0

108.0

113.0

Cooling (nominal)

85.0

90.0

96.0

101.0

High Performance Heating (UK)

95.0

100.0

102.6

107.4

COP Priority Heating (UK)

82.7

87.0

95.0

99.4

Cooling (UK)

78.2

82.8

88.3

92.9

POWER INPUT (kW) Heating (nominal)

24.05

26.04

28.42

30.05

Cooling (nominal)

26.47

28.30

29.26

30.23

High Performance Heating (UK)

30.30

32.81

37.80

39.97

COP Priority Heating (UK)

22.37

24.22

26.15

27.65

Cooling (UK)

17.07

18.25

17.85

18.44

3.95 / 3.21

3.84 / 3.18

3.80 / 3.28

3.76 / 3.34

CAPACITY (kW)

COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min)

High

50

50

50

50

225 / 225

225 / 225

360 / 225

360 / 360

NOISE (dBA)

63.5

64

64.5

65

WEIGHT (kg)

270 + 270

270 + 270

320 + 270

320 + 320 1750 + 1750

Width

1220 + 1220

1220 + 1220

1750 + 1220

Depth

760

760

760

760

Height

1710

1710

1710

1710

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

3

3

3

3

8/8

8/8

8/8

8/8

RUNNING CURRENT (A) Heating

37.1

40.2

43.9

46.4

Cooling

40.9

43.7

45.2

46.7

40 / 32

40 / 40

40 / 40

40 / 40

4 + earth

4 + earth

4 + earth

4 + earth

DIMENSIONS (mm) (1650mm without legs) ELECTRICAL SUPPLY PHASE STARTING CURRENT (A)

FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores

PURY-P900YSJM-A Side View

>

R2 Series Standard (30-36hp)

MODEL REFERENCE

Note: For piping restrictions for PURY-P750-900YSJM-A please see page 196 Page 190

Page 191


Dimensions

Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit

PURY-EP200, 250, 300, 350YJM-A

Improved for even higher efficiency

PURY-EP200YJM-A schematic is the same as PURY-P200, 250, 300YJM-A on page 186

Throughout the year, many buildings require cooling in some areas and heating in others - even in adjacent rooms. The outstanding City Multi R2 system meets this requirement by distributing surplus heat from cooling operations (and vice versa) to rooms where it is needed. This efficiency can result in energy savings of up to 30% over conventional systems.

PURY-EP350YJM-A schematic is the same as PURY-P450YJM-A on page 186

PURY-EP250, 300YJM-A schematic is the same as PURY-P350, 400YJM-A on page 186

PURY-EP400YSJM-A

I

Highest ever COP’s / EER’s due to new high efficiency inverter technology and wrap around coil for added efficiency

I

Up to 50 indoor units connected to each outdoor unit

I

Easy to install unique 2-pipe technology means minimal disruption, quicker installation and less connections than 3 pipe equivalents

I

Weight and size reduction compared to YGM-A models

I

Improved pipe run of 165m with a total system pipe length of up to 750m

I

100% inverter control with low start currents

I

High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

I

High Performance Heating Mode for low ambient conditions

Side View

>

Front View

>

City Multi Range

R2 Series High COP (8-20hp)

Technical Information

PURY-EP450, 500YSJM-A

R2 SERIES HIGH COP OUTDOOR UNITS 8-20hp MODEL REFERENCE

PURY-EP200YJM-A PURY-EP250YJM-A PURY-EP300YJM-A PURY-EP350YJM-A PURY-EP400YSJM-A PURY-EP450YSJM-A PURY-EP500YSJM-A

Heating (nominal)

25.0

31.5

37.5

45.0

50.0

56.0

63.0

Cooling (nominal)

22.4

28.0

33.5

40.0

45.0

50.0

56.0

High Performance Heating (UK)

25.0

31.5

35.6

42.8

47.5

50.7

57.0

48.7

54.8

COP Priority Heating (UK)

22.8

28.7

32.3

38.7

43.0

Cooling (UK)

21.3

26.6

31.5

37.6

42.3

46.0

51.5

POWER INPUT (kW) Heating (nominal)

5.56

7.15

8.60

10.58

11.36

12.87

14.38

Cooling (nominal)

5.07

6.76

8.25

10.28

10.41

11.99

13.62

High Performance Heating (UK)

7.01

9.01

11.52

14.18

15.22

14.67

16.39

COP Priority Heating (UK)

5.50

7.08

8.34

10.26

11.02

11.71

13.09

Cooling (UK)

2.92

3.89

5.32

6.63

6.71

7.55

8.58

4.49 / 4.41

4.40 / 4.14

4.36 / 4.06

4.25 / 3.89

4.40 / 4.32

4.35 / 4.17

4.38 / 4.11

COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS

20

25

30

35

40

45

50

AIRFLOW (m3/min)

185

225

225

360

185 / 185

225 / 185

225 / 185

High

NOISE (dBA)

57

60

60

61

60

62

62

WEIGHT (kg)

240

270

270

320

240 + 240

270 + 240

270 + 240 1220 + 920

DIMENSIONS (mm) (1650mm without legs)

Width

920

1220

1220

1750

920 + 920

1220 + 920

Depth

760

760

760

760

760

760

760

Height

1710

1710

1710

1710

1710

1710

1710 380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

PHASE

3

3

3

3

3

3

3

STARTING CURRENT (A)

8

8

8

8

8/8

8/8

8/8

RUNNING CURRENT (A) Heating

8.5

11.0

13.2

16.3

17.5

19.8

22.2

Cooling

7.8

10.4

12.7

15.8

16.0

18.5

21.0

20

20

25

32

20 / 20

20 / 20

25 / 20

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

ELECTRICAL SUPPLY

FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores

Side View

>

Front View

> R2 Series High COP (8-20hp)

CAPACITY (kW)

Note: For piping restrictions for PURY-EP200-500Y(S)JM-A please see page 196 Page 192

Page 193


Dimensions

Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit

PURY-EP550, 600YSJM-A Side View

Improved for even higher efficiency

>

Front View

>

Throughout the year, many buildings require cooling in some areas and heating in others - even in adjacent rooms. The outstanding City Multi R2 system meets this requirement by distributing surplus heat from cooling operations (and vice versa) to rooms where it is needed. This efficiency can result in energy savings of up to 30% over conventional systems. I

Highest ever COP’s / EER’s due to new high efficiency inverter technology and wrap around coil for added efficiency

I

Up to 50 indoor units connected to each outdoor unit

I

Easy to install unique 2-pipe technology means minimal disruption, quicker installation and less connections than 3 pipe equivalents

I

Weight and size reduction compared to YGM-A models

I

Improved pipe run of 165m with a total system pipe length of up to 800m

I

100% inverter control with low start currents

I

High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

I

City Multi Range

R2 Series High COP (22-28hp)

PURY-EP650YSJM-A Side View

>

Front View

>

High Performance Heating Mode for low ambient conditions

Technical Information R2 SERIES HIGH COP OUTDOOR UNITS 22-28hp PURY-EP550YSJM-A

PURY-EP600YSJM-A

PURY-EP650YSJM-A

PURY-EP700YSJM-A

Heating (nominal)

69.0

76.5

81.5

88.0

Cooling (nominal)

63.0

69.0

73.0

80.0

High Performance Heating (UK)

62.4

69.2

73.8

88.0

COP Priority Heating (UK)

60.0

66.6

70.9

76.6

Cooling (UK)

58.0

63.5

67.2

73.6

POWER INPUT (kW) Heating (nominal)

15.93

17.38

19.73

22.05

Cooling (nominal)

15.40

16.87

19.01

21.22

High Performance Heating (UK)

18.16

19.81

22.49

27.78

COP Priority Heating (UK)

14.50

15.82

17.95

20.51

Cooling (UK)

9.70

10.63

11.98

13.69

4.33 / 4.09

4.40 / 4.09

4.13 / 3.84

3.99 / 3.77

CAPACITY (kW)

COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min)

High

50

50

50

50

225 / 225

225 / 225

360 / 225

360 / 360

NOISE (dBA)

63

63

63.5

64

WEIGHT (kg)

270 + 270

270 + 270

320 + 270

320 + 320 1750 + 1750

DIMENSIONS (mm)

Width

1220 + 1220

1220 + 1220

1750 + 1220

Depth

760

760

760

760

Height

1710

1710

1710

1710

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

380-415v, 50Hz

3

3

3

3

8/8

8/8

8/8

8/8

RUNNING CURRENT (A) Heating

24.6

26.8

30.4

34.0

Cooling

23.8

26.0

29.3

32.8

25 / 20

25 / 25

32 / 25

32 / 32

4 + earth

4 + earth

4 + earth

4 + earth

(1650mm without legs) ELECTRICAL SUPPLY PHASE STARTING CURRENT (A)

FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores

PURY-EP700YSJM-A Side View

>

Front View

>

R2 Series High COP (22-28hp)

MODEL REFERENCE

Note: For piping restrictions for PURY-EP550-700YSJM-A please see page 196 Page 194

Page 195


City Multi Range

R2 Series Piping Restrictions R2 SERIES PIPING RESTRICTIONS

TABLE 1: TOTAL PIPE LENGTH OUTDOOR MODEL

MAX LENGTH

P200, P250, P300, EP200 P350, P400, P450, EP250, EP300, EP350 P500, P550, EP400, EP450, EP500, EP550 P600, P650, EP600, EP650, EP700 P700, P750, P800, P850, P900

550m*1 600m*1 750m*1 800m*1 950m*1

1

*1 Please refer to Graph 1

R2 SERIES PIPING RESTRICTIONS

GRAPH 1: TOTAL PIPING LENGTH RESTRICTIONS

PIPING LENGTH (>1 BC CONTROLLER FOR 1 OUTDOOR UNIT)

ITEM

1000

Total Extended Pipe Length (m)

900 800 700

PURY-P700,750,800,850,900YSJM-A

600 PURY-P600,650YSJM-A, PURY-EP600,650,700YSJM-A PURY-P500,550YSJM-A, PURY-EP400,450,500,550YSJM-A

500 400

PURY-P350,400,450Y(S)JM-A(1), PURY-EP250,300,350YJM-A

300

PIPE SECTION A+B+C+D+E+a+b+c+d+e+f A+C+E+f A B+d or C+D+e or C+E+f H H1 h1 h2 h3

Total Piping Length Furthest Piping Length Length Between OU and BC Length Between Furthest IU and BC Height Between OU and IU (OU above IU) Height Between OU and IU (OU below IU) Height Between IU and BC Height Between IU and IU Height Between BC (Main or Sub) and BC (Sub)

MAX LENGTH (See Table 1) 165m 110m*1 60m*2 (40m) 50m 40m 15m 15m 15m

PURY-P200,250,300YJM-A, PURY-EP200YJM-A

*1 Please refer to Graph 1. *2 Height difference between BC controller and furthest indoor unit is zero.

200 100 0 10

20

30

40

50

60

70

80

90

100

110

Distance Between Outdoor Unit and BC Controller (m)

R2 SERIES PIPING RESTRICTIONS / EP600 or less 700 to P800 CMY-R100XLVBK: Outdoor unit EP650 and EP700 CMY-R200XLVBK: Outdoor unit P850 and P900

1

1

R2 SERIES PIPING RESTRICTIONS

R2 SERIES PIPING RESTRICTIONS

PIPING LENGTH (>1 BC CONTROLLER FOR 2 OUTDOOR UNITS)

PIPING LENGTH (1 BC CONTROLLER, NO SUB BC CONTROLLER)

ITEM Total Piping Length Furthest Piping Length Length Between OU and BC Length Between Furthest IU and BC Height Between OU and IU (OU above IU) Height Between OU and IU (OU below IU) Height Between IU and BC Height Between IU and IU *1 Please refer to Graph 1. *2 Height difference between BC controller and furthest indoor unit is zero.

R2 Series Piping Restrictions

1

PIPE SECTION A+B+a+b+c+d A+B+d A B+d H H1 h1 h2

MAX LENGTH (See Table 1) 165m 110m*1 60m*2 (40m) 50m 40m 15m 15m

PIPE SECTION

ITEM Total Piping Length Furthest Piping Length Length Between OU and BC Length Between Furthest IU and BC Height Between OU and IU (OU above IU) Height Between OU and IU (OU below IU) Height Between IU and BC Height Between IU and IU Height Between BC (Main or Sub) and BC (Sub) Length Between Main OU and Sub OU Height Between Main OU and Sub OU

F+G+H+A+B+C+D+E+a+b+c+d+e+f F(G)+A+C+E+f F(G)+A B+d or C+D+e or C+E+f H H1 h1 h2 h3 F+G or H h4

MAX LENGTH (See Table 1) 165m 110m*1 60m*2 (40m) 50m 40m 15m 15m 15m 5m 0.1m

*1 Please refer to Graph 1. *2 Height difference between BC controller and furthest indoor unit is zero.

Page 196

Page 197


Dimensions

Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit

PURY-RP200, 250, 300YJM-B

upper view

>

enables the replacement of vrF systems, whilst utilising existing r22 / r407c pipework. The latest VRF Replace Multi from Mitsubishi Electric is specifically designed for the maturing refurbishment sector, enabling the reuse of existing R22 / R407c pipework, whilst also allowing the upgrade to some of the most efficient systems available in the market. Replace Multi will clean the existing pipework during commissioning, removing any deposits and R22 mineral oil that would have ordinarily meant that new pipework would have been called for. The implications of this are significant savings on cost and time, whilst also minimising any potential disruption. I I I I I I I I

tried and tested technology that has been employed for over 5 years efficient use of existing resources - refrigerant piping, control and power wiring and less waste materials increased energy efficiency - up to 105% (size 200) more efficient than an old mitsubishi electric r22 system reduced installation costs of up to 55% reduced co2 emissions and running cost savings of up to 45% reduced installation time with minimised disruption ability to replace many non mitsubishi electric systems high Performance heating mode for low ambient conditions

side view

>

Front view

>

city multi Range

r2 series replace multi (8-12hp)

Technical Information model reFerence

PURY-RP200YJM-B

PURY-RP250YJM-B

PURY-RP300YJM-B

heating (nominal)

25.0

31.5

37.5

cooling (nominal)

22.4

28.0

33.5

high Performance heating (uK)

24.0

30.2

36.0

coP Priority heating (uK)

21.8

27.4

32.6

cooling (uK)

21.1

26.3

31.5

Power inPut (kw) heating (nominal)

5.50

7.22

8.70

cooling (nominal)

4.95

6.82

8.35

high Performance heating (uK)

7.26

9.53

11.48

coP Priority heating (uK)

5.34

7.00

8.44

cooling (uK)

3.61

4.98

6.10

4.54 / 4.52

4.36 / 4.10

4.31 / 4.01

caPacity (kw)

coP / eer (nominal) max no. oF connectable indoor units

20

25

30

airFlow (m3/min)

225

225

225

high

noise (dba)

56

57

59

weight (kg)

275

290

290 1220

dimensions (mm) (1650mm without legs)

width

1220

1220

depth

760

760

760

height

1710

1710

1710

electrical suPPly

380-415v, 50hz

380-415v, 50hz

380-415v, 50hz

Phase

3

3

3

starting current (a)

8

8

8

heating

8.9

11.9

14.6

cooling

8.0

11.2

13.6

20

20

25

4 + earth

4 + earth

4 + earth

running current (a)

Fuse rating (mcb sizes bs en 60947-2) - (a) mains cable no. cores

r2 series replace multi (8-12hp)

R2 SERIES REPLACE MULTI OUTDOOR UNITS 8-12hp

R2 Series Replace Multi Piping Restrictions total PiPing length

220m max

height between ou and iu (ou above iu)

50m max

Furthest PiPing length

100m max

height between ou and iu (ou below iu)

40m max

length between ou and bc

70m max

height between iu and bc

15m max

length between Furthest iu and bc

30m max

height between iu and iu

15m max

height between bc (main or sub) and sub bc

15m max

Page 198

Page 199


Dimensions

Water Cooled Condensing Unit Simultaneous Heating and Cooling with Double Heat Recovery

PQRY-P200, 250, 300YHM-A upper view

The WR2 system has double heat recovery potential, making this system very economical. Not only does it produce heat recovery from indoor units on the same refrigerant circuit, it also produces heat recovery via the water circuit between heat source units. Like the YHM-A air source versions, the water cooled units now benefit from a modular design approach. A twinning kit is required for double combinations. I

all the benefits of the r2 series with water cooled condensing units, using a single inverter compressor

I

40% height reduction compared to previous ygm-a models

I

high coPs possible thanks to increased efficiency and careful control of the system, allowing the largest operational water circuit temperature band ever

I

unique 2-pipe refrigerant circuit allows simultaneous heating and cooling plus heat recovery between up to 50 indoor units as with the r2 system

I

total building heat recovery made possible by exchanging energy in both refrigerant and water circuits

I

combining wr2 with waste heat energy provides unique application solutions

I

improved pipe run of 165m with a total system pipe length of up to 750m

I

high sensible cooling Function - by raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

I

able to operate with closed loop ground source water temperatures, bore hole and slinky applications are now possible

I

easy maintenance - front panel access to all Pcb’s

I

condensing units must be situated indoors

Front view

>

>

right side view

>

city multi Range

wr2 series (8-24hp)

Technical Information WR2 SERIES HEAT SOURCE UNITS - 8-24hp model reFerence

Power inPut (kw)

PQRY-P200YHM-A PQRY-P250YHM-A PQRY-P300YHM-A PQRY-P400YSHM-A PQRY-P450YSHM-A PQRY-P500YSHM-A PQRY-P550YSHM-A PQRY-P600YSHM-A heating (nominal)

25.0

31.5

37.5

50.0

56.0

63.0

69.0

cooling (nominal)

22.4

28.0

33.5

45.0

50.0

56.0

63.0

69.0

heating (nominal)

4.12

5.80

8.15

8.65

10.42

12.06

14.65

17.12

cooling (nominal) coP / eer (nominal)

76.5

3.96

5.51

7.44

8.32

9.94

11.57

13.60

15.62

6.06 / 5.65

5.43 / 5.08

4.60 / 4.50

5.78 / 5.40

5.37 / 5.03

5.22 / 4.84

4.70 / 4.63

4.46 / 4.41 50

max no. oF connectable indoor units

20

25

30

40

45

50

50

noise (dba)

47

49

50

50

51

52

52.5

53

weight (kg)

181

181

181

181 + 181

181 + 181

181 + 181

181 + 181

181 + 181

width

880

880

880

880 + 880

880 + 880

880 + 880

880 + 880

880 + 880

depth

550

550

550

550

550

550

550

550

height

1160

1160

1160

1160

1160

1160

1160

1160

dimensions (mm)

(1100 without legs) electrical suPPly

380-415v, 50hz 380-415v, 50hz 380-415v, 50hz 380-415v, 50hz

380-415v, 50hz

3

3

3

3

3

3

3

3

starting current (a)

8

8

8

8/8

8/8

8/8

8/8

8/8

heating

6.3

8.9

12.5

13.3

16.1

18.6

22.6

26.4

cooling

6.1

8.5

11.5

12.8

15.3

17.8

21.0

24.1

20

20

20

20 / 20

20 / 20

20 / 20

20 / 20

20 / 20

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

Fuse rating (bs88) - hrc (a) mains cable no. cores

left side view

>

Front view

>

380-415v, 50hz 380-415v, 50hz 380-415v, 50hz

Phase

running current (a)

PQRY-P400, 450, 500, 550, 600YSHM-A

wr2 series (8-24hp)

caPacity (kw)

PQRY-P200-600Y(S)HM-A Piping restrictions total PiPing length Furthest PiPing length between outdoor and bc controller (master) - length

550m max*3 (300m) for sizes 200-300 / 750m max*3 (500m) for sizes 400-600 165m max 110m max*4

between indoor and bc controller (master/slave) - length

60m max*5 (40m)

between indoor and outdoor - height

50m max (40m*1)

between indoor and indoor - height

15m max (10m*2)

between indoor and bc controller (master/slave) - height

15m max (10m*2)

between bc controller (master) and bc controller (slave) - height

15m max (10m)*6

*1 When O/U is below indoor *2 In case of P200, P250 indoor unit *3 Distance between outdoor unit and BC Controller is 10m or less *4 Total piping length is 300m or less (500m for sizes 400-600) *5 Height difference between the Master BC Controller and furthest indoor unit is zero and no size 200 or 250 indoor unit is used *6 When using 2 sub BC Controllers, the height between them should be considered

Page 200

Page 201


Dimensions

Heat Pump Close Control System

PFD-P250VM-E

Mitsubishi Electric’s new Close Control System is specifically designed for computer rooms, laboratories etc, where a need for high sensible cooling and close control of temperature and humidity is required. Because of the need for close control 24 hours a day, 365 days a year, a newly developed inverter driven compressor has been incorporated into the outdoor unit, maximising the energy efficiency of the PFD series. It is also able to be connected to a computer network using our AG150 controller, in order to monitor and provide remote email alarms.

upper view

Front view high sensible cooling

I

newly developed inverter driven compressor

I

energy efficient with high coP’s

I

close control of temperature, ±1ºc

I

easy to install - no service space needed at the rear of the unit

I

optional third party humidifier available

I

Quick recovery following power failure

I

return or discharge air temperature control

I

back-up & rotate function available

I

connectable to Puhy-P250yJm-a from april 2011

Technical Information PFD-P-VM-E - INDOOR UNITS

PUHY-P-YJM-A - OUTDOOR UNITS

PQHY-P-YHM-A - CONDENSING UNITS

PFD-P250VM-E

PFD-P500VM-E

PUHY-P250YJM-A

PUHY-P250YJM-A x2

PQHY-P250YHM-A PQHY-P250YHM-A x2

heating (nominal)

31.5

63.0

31.5

63.0

31.5

63.0

cooling (nominal)

28.0

56.0

28.0

56.0

28.0

56.0

heating (uK)

29.1

55.4

28.7

54.8

n/a

n/a

cooling (uK)

26.6

51.5

26.6

51.5

n/a

n/a

0.93

0.93

n/a

n/a

n/a

n/a

2.5

5.0

refer to databook

refer to databook

5.51

5.51 / 5.51

model reFerence caPacity (kw)

shF Power inPut (kw)

heating (nominal) cooling (nominal)

2.5

5.0

refer to databook

refer to databook

5.45

5.45 / 5.45

heating (uK)

n/a

n/a

refer to databook

refer to databook

n/a

n/a

cooling (uK)

n/a

n/a

refer to databook

refer to databook

n/a

n/a

160

320

170

170 / 170

n/a

n/a

airFlow (m3/min) external static Pressure (Pa) PiPe siZe mm(in)

120

120

n/a

n/a

n/a

n/a

gas

22.2 (7/8”)

22.2 (7/8”)

22.2 (7/8”)

22.2 (7/8”)

22.2 (7/8”)

22.2 (7/8”)

liquid

9.52 (3/8”)

9.52 (3/8”)

9.52 (3/8”)

9.52 (3/8”)

9.52 (3/8”)

9.52 (3/8”)

noise (dba)

59

63

58

58 / 58

49

49 / 49

weight (kg)

380

520

200

200 + 200

195

195 + 195 880 + 880

dimensions (mm)

width

1380

1980

920

920 + 920

880

depth

780

780

760

760

550

550

height

1950

1950

1710

1710

1160

1160 380-415v, 50hz

electrical suPPly

380-415v, 50hz

380-415v, 50hz

380-415v, 50hz

380-415v, 50hz

380-415v, 50hz

Phase

3

3

3

3

3

3

starting current (a)

47

68

8

8/8

8

8/8

heating

4.9

8.7

refer to databook

refer to databook

8.5

8.5 / 8.5

cooling

4.9

8.7

refer to databook

refer to databook

8.4

8.4 / 8.4

16

20

20

20 / 20

20

20 / 20

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

4 + earth

running current (a)

Fuse rating (bs88) - hrc (a) mains cable no. cores

>

side view

>

PFD-P500VM-E upper view

Front view

>

>

side view

>

PFd-P-vm-e (10/20hp)

I

>

PFD-P-VM-E Piping restrictions total PiPing length between indoor and outdoor units - height

Page 202

city multi Range

PFd-P-vm-e (10/20hp)

165m max 50m max (40m max if outdoor installed below)

Page 203


Dimensions

2, 3 and 4-Way Blow Ceiling Cassette Indoor Unit

PLFY-P32, 40, 50, 63, 80, 100, 125VBM-E

Power cassettes offer 72 different airflow patterns, with the ability to handle a multitude of ceiling applications up to 4.2 metres in height. The easy to install, slim unit is ideal for maintaining constant temperatures, thanks to adjustable vanes that allow users to precisely direct air where it’s needed.

upper view

>

lower view

>

The Mitsubishi Electric airflow control mechanism has been improved and uses wider vanes so that the unit reduces drafts and smudging, whilst a high performance drain pump on the drain lift mechanism allows drain water to be lifted up to 850mm from the ceiling surface. I

handy corner pocket design simplifies maintenance

I

airflow controllable for ceiling heights up to 4.2m, with automatic adjustment of fan speed

I

reduced draft air distribution, with independent vane control

I

drain pump as standard, 850mm from drain pan

I

Filter lowering operation down to 4m (optional PlP-6baJ grille required)

I

optional ‘i see sensor’ for energy saving and smooth temperature control throughout the room

I

For further information on the features of this cassette, please see page 72

city multi Range

PlFy-P-vbm-e

Technical Information PLFY-P-VBM-E - INDOOR UNITS PLFY-P32VBM-E

PLFY-P40VBM-E

PLFY-P50VBM-E

PLFY-P63VBM-E

PLFY-P80VBM-E

PLFY-P100VBM-E

PLFY-P125VBM-E

heating (nominal)

4.0

5.0

6.3

8.0

10.0

12.5

16.0

cooling (nominal)

3.6

4.5

5.6

7.1

9.0

11.2

14.0

hP heating (uK)

4.0

5.0

6.3

8.0

10.0

12.5

16.0

coP P heating (uK)

3.7

4.7

5.9

7.5

9.4

11.7

15.0

cooling (uK)

3.4

4.3

5.3

6.7

8.5

10.6

13.3

high sensible

cooling (uK)

2.6

3.3

4.1

5.2

6.5

8.1

10.2

shF

(uK)

0.82

0.79

0.75

0.73

0.72

0.72

0.70

high sensible

(uK)

0.96

0.91

0.83

0.79

0.78

0.79

0.75

Power inPut (kw)

heating (nominal)

0.02

0.03

0.03

0.04

0.06

0.14

0.15

cooling (nominal)

0.03

0.04

0.04

0.05

0.07

0.15

0.16

caPacity (kw)

airFlow (m3/min)

lo-mi1-mi2-hi

11-12-13-14

12-13-14-16

12-13-14-16

14-15-16-18

16-18-20-22

21-24-27-29

22-25-28-30

noise (dba)

lo-mi1-mi2-hi

27-28-29-31

27-28-30-31

27-28-30-31

28-29-30-32

30-32-35-37

34-37-39-41

35-38-41-43

weight (kg)

(grille)

22(6)

22(6)

22(6)

23(6)

23(6)

27(6)

27(6)

dimensions (mm)

width (grille)

840(950)

840(950)

840(950)

840(950)

840(950)

840(950)

840(950)

depth (grille)

840(950)

840(950)

840(950)

840(950)

840(950)

840(950)

840(950)

height (grille)

258(35)

258(35)

258(35)

258(35)

258(35)

298(35)

298(35)

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

single

single

single

single

single

single

single

running current (a) heating

0.14

0.22

0.22

0.29

0.43

0.94

1.00

cooling

0.22

0.29

0.29

0.36

0.51

1.00

1.07

Fuse rating (bs88) - hrc (a)

6

6

6

6

6

6

6

mains cable no. cores

3

3

3

3

3

3

3

PlP-6ba

PlP-6ba

PlP-6ba

PlP-6ba

PlP-6ba

PlP-6ba

PlP-6ba

electrical suPPly Phase

grille model reFerence

Page 204

side view

>

MODELS

A

B

PlFy-P32-80vbm-e

241

258

PlFy-P100-125vbm-e

281

298

PlFy-P-vbm-e

model reFerence

Page 205


Dimensions

600x600 4-Way Blow Ceiling Cassette Indoor Unit

PLFY-P20, 25, 32, 40VCM-E2

The compact size of this unit is ideal for 600x600mm ceilings and with a depth of 208mm, this lightweight unit makes installation a breeze. This unit also comes complete with a long life filter that will last for approximately 2,500 hours. I

compact size for handy installation and easy maintenance

I

only 208mm high

I

Fresh air duct facility

lower view

Technical Information

side view

>

city multi Range

PlFy-P-vcm-e2

>

model reFerence

PLFY-P20VCM-E2

PLFY-P25VCM-E2

PLFY-P32VCM-E2

PLFY-P40VCM-E2

heating (nominal)

2.5

3.2

4.0

5.0

cooling (nominal)

2.2

2.8

3.6

4.5

hP heating (uK)

2.5

3.2

4.0

5.0

coP P heating (uK)

2.3

3.0

3.7

4.7

cooling (uK)

2.1

2.7

3.4

4.3

high sensible

cooling (uK)

1.6

2.0

2.6

3.3

shF

(uK)

0.86

0.78

0.76

0.70

high sensible

(uK)

1.00

0.95

0.85

0.76

Power inPut (kw)

heating (nominal)

0.05

0.05

0.06

0.06

cooling (nominal)

0.05

0.05

0.06

0.06

lo-mi-hi

8-9-10

8-9-10

8-9-11

8-9-11

noise (dba)

lo-mi-hi

28-31-35

28-31-37

29-33-38

30-34-39

weight (kg)

(grille)

15.5(3)

15.5(3)

17(3)

17(3)

dimensions (mm)

width (grille)

570(650)

570(650)

570(650)

570(650)

depth (grille)

570(650)

570(650)

570(650)

570(650)

height (grille)

235(20)

235(20)

235(20)

235(20)

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

caPacity (kw)

airFlow (m3/min)

electrical suPPly

single

single

single

single

heating

0.23

0.23

0.28

0.28

cooling

0.23

0.23

0.28

0.28

Fuse rating (bs88) - hrc (a)

6

6

6

6

mains cable no. cores

3

3

3

3

slP-2aaw

slP-2aaw

slP-2aaw

slP-2aaw

Phase running current (a)

grille model reFerence

Page 206

PlFy-P-vcm-e2

PLFY-P-VCM-E2 - INDOOR UNITS

Page 207


Dimensions

PLFY-P20, 25, 32, 40, 50, 63, 80, 100VLMD-E

2-Way Blow Ceiling Cassette Indoor Unit

Front view

The PLFY-P-VLMD-E cassette unit fits into the space in a suspended ceiling to provide heating or cooling. This new unit has been redesigned with lower unit height and lower noise levels. I

light unit for ease of installation

I

terminal block on outside of unit for easy wiring

I

drain lift-pump mechanism as standard

I

newly designed pure white decoration panel with air flow switching and swing functions as standard

>

lower view

upper view

>

>

city multi Range

PlFy-P-vlmd-e

Technical Information PLFY-P-VLMD-E - INDOOR UNITS model reFerence

PLFYP20VLMD-E

PLFYP25VLMD-E

PLFYP32VLMD-E

PLFYP40VLMD-E

PLFYP50VLMD-E

PLFYP63VLMD-E

heating (nominal)

2.5

3.2

4.0

5.0

6.3

8.0

10.0

12.5

16.0

cooling (nominal)

2.2

2.8

3.6

4.5

5.6

7.1

9.0

11.2

14.0

hP heating (uK)

2.5

3.2

4.0

5.0

6.3

8.0

10.0

12.5

16.0

coP P heating (uK)

2.3

3.0

3.7

4.7

5.9

7.5

9.4

11.7

15.0

cooling (uK)

2.1

2.7

3.4

4.3

5.3

6.7

8.5

10.6

13.3

high sensible

cooling (uK)

1.6

2.0

2.6

3.3

4.1

5.2

6.5

8.1

10.2

shF

(uK)

0.90

0.78

0.74

0.70

0.72

0.70

0.73

0.73

0.73

high sensible

(uK)

1.00

0.90

0.85

0.76

0.78

0.75

0.82

0.79

0.80

Power inPut (kw) heating (nominal)

0.065

0.065

0.065

0.074

0.075

0.094

0.140

0.150

0.27

cooling (nominal)

0.072

0.072

0.072

0.081

0.082

0.101

0.147

0.157

0.28

caPacity (kw)

side view

PLFYPLFYPLFYP80VLMD-E P100VLMD-E P125VLMD-E

>

CMP-40VLW-C

CMP-63VLW-C CMP-100VLW-C

lo-mi1-mi2-hi

6.5-8.0-9.5

6.5-8.0-9.5

6.5-8.0-9.5

7.0-8.5-10.5

9.0-11.0-12.5

10.0-13.0-15.5

15.5-18.5-22.0

17.5-21.0-25.0

24-27-30-33

noise (dba)

lo-mi1-mi2-hi

27-30-33

27-30-33

27-30-33

29-33-36

31-34-37

32-37-39

33-36-39

36-39-42

40-42-44-46

weight (kg)

(grille)

23(6.5)

23(6.5)

24(6.5)

24(6.5)

27(7.5)

28(7.5)

44(12.5)

47(12.5)

56(13)

dimensions (mm)

width (grille)

776(1080)

776(1080)

776(1080)

776(1080)

946(1250)

946(1250)

1446(1750)

1446(1750)

1708(2010)

depth (grille)

634(710)

634(710)

634(710)

634(710)

634(710)

634(710)

634(710)

634(710)

606(710)

height (grille)*1

290(20)

290(20)

290(20)

290(20)

290(20)

290(20)

290(20)

290(20)

290(20)

220-240v,

220-240v,

220-240v,

220-240v,

220-240v,

220-240v,

220-240v,

220-240v,

220-240v,

50hz

50hz

50hz

50hz

50hz

50hz

50hz

50hz

50hz

Phase

single

single

single

single

single

single

single

single

single

running current (a) heating

0.30

0.30

0.30

0.34

0.35

0.43

0.66

0.69

1.33

cooling

0.36

0.36

0.36

0.40

0.41

0.49

0.72

0.75

1.35

Fuse rating (bs88) - hrc (a)

6

6

6

6

6

6

6

6

6

mains cable no. cores

3

3

3

3

3

3

3

3

3

cmP40vlw-c

cmP40vlw-c

cmP40vlw-c

cmP40vlw-c

cmP63vlw-c

cmP63vlw-c

cmP100vlw-c

cmP100vlw-c

cmP125vlw-c

electrical suPPly

grille model reFerence

side view

>

rear view

>

upper view

>

lower view

>

PlFy-P-vlmd-e

airFlow (m3/min)

PLFY-P125VLMD-E

*1 Void space required is 350mm or more

Page 208

Page 209


Dimensions

1-Way Blow Ceiling Cassette Indoor Unit

PMFY-P20, 25, 32, 40VBM-E

Utilising a compact and lightweight body, the unit is perfect for applications where ceiling space is limited. A total body weight of 14kg makes it one of the lightest available, latest fan technology also makes it one of the quietest. I

compact size for handy installation and easy maintenance

I

newly developed airflow control technology reduces noise levels to only 27dba

I

drain lift pump mechanism allows the drain to be positioned anywhere up to 600mm from the ceiling’s surface

I

only 230mm high

I

Fresh air duct facility

I

Pure white grille

upper view

>

lower view

>

city multi Range

PmFy-P-vbm-e

Technical Information PMFY-P-VBM-E - INDOOR UNITS caPacity (kw)

PMFY-P20VBM-E

PMFY-P25VBM-E

PMFY-P32VBM-E

PMFY-P40VBM-E

heating (nominal)

2.5

3.2

4.0

5.0

cooling (nominal)

2.2

2.8

3.6

4.5

hP heating (uK)

2.5

3.2

4.0

5.0

coP P heating (uK)

2.3

3.0

3.7

4.7 4.3

cooling (uK)

2.1

2.7

3.4

high sensible

cooling (uK)

1.6

2.0

2.6

3.3

shF

(uK)

0.86

0.81

0.76

0.72

high sensible

(uK)

1.00

0.95

0.85

0.82

Power inPut (kw)

heating (nominal)

0.042

0.044

0.044

0.054

cooling (nominal)

0.042

0.044

0.044

0.054

lo-mi1-mi2-hi

6.5-7.2-8.0-8.7

7.3-8.0-8.6-9.3

7.3-8.0-8.6-9.3

7.7-8.7-9.7-10.7

noise (dba)

lo-mi1-mi2-hi

27-30-33-35

32-34-36-37

32-34-36-37

33-35-37-39

weight (kg)

(grille)

14(3)

14(3)

14(3)

14(3)

dimensions (mm)

width (grille)

812(1000)

812(1000)

812(1000)

812(1000)

depth (grille)

395(470)

395(470)

395(470)

395(470)

height (grille)

230(30)

230(30)

230(30)

230(30)

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

airFlow (m3/min)

electrical suPPly Phase

single

single

single

single

heating

0.20

0.21

0.21

0.26

cooling

0.20

0.21

0.21

0.26

Fuse rating (bs88) - hrc (a)

6

6

6

6

mains cable no. cores

3

3

3

3

PmP-40bmw

PmP-40bmw

PmP-40bmw

PmP-40bmw

running current (a)

grille model reFerence

Page 210

side view

>

Front view

>

PmFy-P-vbm-e

model reFerence

Page 211


Ultra Thin Ceiling Concealed Ducted Indoor Unit

PEFY-P15, 20, 25, 32, 40, 50, 63 VMS1-E

The ultra thin ceiling concealed ducted indoor unit offers increased flexibility and is particularly suitable for places where low noise operation is desired from a slimline body. I

ultra thin body - height of only 200mm & width of only 790mm (P15-32)

I

extremely quiet operation - as low as 22dba

I

cooling operation set temperature can be set down to 14째c db

I

static pressure of 5-50Pa

I

now available in a size 15, ideal for hotel rooms

upper view

side view

>

city multi Range

PeFy-P-vms1-e

Dimensions

>

Technical Information PEFY-P-VMS1-E - INDOOR UNITS PEFY-P25VMS1-E

PEFY-P32VMS1-E

PEFY-P40VMS1-E

PEFY-P50VMS1-E

PEFY-P63VMS1-E

heating (nominal)

1.9

2.5

3.2

4.0

5.0

6.3

8.0

cooling (nominal)

1.7

2.2

2.8

3.6

4.5

5.6

7.1

hP heating (uK)

1.9

2.5

3.2

4.0

5.0

6.3

8.0

coP P heating (uK)

1.8

2.3

3.0

3.7

4.7

5.9

7.5

cooling (uK)

1.6

2.1

2.7

3.4

4.3

5.3

6.7

high sensible

cooling (uK)

1.2

1.6

2.0

2.6

3.3

4.1

5.2

shF

(uK)

0.94

0.86

0.78

0.76

0.72

0.72

0.73

high sensible

(uK)

1.00

1.00

0.90

0.85

0.82

0.78

0.79

Power inPut (kw)

heating (nominal)

0.03

0.03

0.04

0.05

0.05

0.07

0.07

cooling (nominal)

0.05

0.05

0.06

0.07

0.07

0.09

0.09

5.0-6.0-7.0

5.5-6.5-8.0

5.5-7.0-9.0

6.0-8.0-10.0

8.0-9.5-11.0

9.5-11.0-13.0

12.0-14.0-16.5

5-15-35-50

5-15-35-50

5-15-35-50

5-15-35-50

5-15-35-50

5-15-35-50

5-15-35-50

22-24-28

22-25-29

24-26-30

24-27-32

28-30-33

30-32-35

30-33-36

19

19

19

20

24

24

28

width

790

790

790

790

990

990

1190

depth

700

700

700

700

700

700

700

height

200

200

200

200

200

200

200

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

single

single

single

single

single

single

single

running current (a) heating

0.31

0.36

0.39

0.39

0.45

0.56

0.61

cooling

0.42

0.47

0.50

0.50

0.56

0.67

0.72

Fuse rating (bs88) - hrc (a)

6

6

6

6

6

6

6

mains cable no. cores

3

3

3

3

3

3

3

caPacity (kw)

airFlow (m3/min)

PEFY-P15VMS1-E PEFY-P20VMS1-E

lo-mi-hi

external static Pressure (Pa) lo-mi1-mi2-hi noise (dba) (15Pa)

lo-mi-hi

weight (kg) dimensions (mm)

electrical suPPly Phase

Page 212

Front view

>

model

a

b

c

d

700 752 798 660 PeFy-P40-50vms1-e 900 952 998 860 PeFy-P63vms1-e 1100 1152 1198 1060 PeFy-P15-32vms1-e

e

F

7 9 11

600 800 1000

PeFy-P-vms1-e

model reFerence

Page 213


Dimensions

Ceiling Concealed Ducted Indoor Unit

PEFY-P20, 25, 32, 40, 50, 63, 80, 100, 125VMA-E

The PEFY-P-VMA-E ducted indoor unit is concealed within the ceiling space to allow unobtrusive air conditioning. Flexibility of duct layout allows air flow patterns to be arranged to suit any application.

Front view

I

reduced height - now only 250mm

I

wider range of external static pressure settings across entire range

I

reduced noise levels thanks to the use of a newly designed centrifugal fan - as low as 23dba

I

cooling operation set temperature can be set down to 14ยบc db

I

drain pump included as standard

>

upper view

>

city multi Range

PeFy-P-vma-e

Technical Information PEFY-P-VMA-E - INDOOR UNITS model reFerence

PEFYP20VMA-E

PEFYP25VMA-E

PEFYP32VMA-E

PEFYP40VMA-E

PEFYP50VMA-E

PEFYP63VMA-E

PEFYP80VMA-E

PEFYP100VMA-E

PEFYP125VMA-E

heating (nominal)

2.5

3.2

4.0

5.0

6.3

8.0

10.0

12.5

16.0

cooling (nominal)

2.2

2.8

3.6

4.5

5.6

7.1

9.0

11.2

14.0

hP heating (uK)

2.5

3.2

4.0

5.0

6.3

8.0

10.0

12.5

16.0

coP P heating (uK)

2.3

3.0

3.7

4.7

5.9

7.5

9.4

11.7

15.0

cooling (uK)

2.1

2.7

3.4

4.3

5.3

6.7

8.5

10.6

13.3

high sensible

cooling (uK)

1.6

2.0

2.6

3.3

4.1

5.2

6.5

8.1

10.2

shF

(uK)

0.90

0.78

0.74

0.79

0.79

0.78

0.72

0.79

0.77

high sensible

(uK)

1.00

0.90

0.85

0.91

0.88

0.87

0.78

0.89

0.86

Power inPut (kw) heating (nominal)

0.04

0.04

0.05

0.07

0.09

0.10

0.12

0.22

0.32

cooling (nominal)

0.06

0.06

0.07

0.09

0.11

0.12

0.14

0.24

0.34

6.0-7.5-8.5

6.0-7.5-8.5

7.5-9.0-10.5

10-12-14

12.0-14.5-17.0

13.5-16.0-19.0

14.5-18.0-21.0

23-28-33

28-34-40

caPacity (kw)

airFlow (m3/min)

lo-mi-hi

rear view

>

side view

>

noise (dba) (50Pa)

lo-mi-hi

23-25-26

23-25-26

23-26-29

23-27-30

25-29-32

25-29-33

26-29-34

28-33-37

32-36-40

23

23

23

26

26

32

32

42

42

width

700

700

700

900

900

1100

1100

1400

1400

depth

732

732

732

732

732

732

732

732

732

height

250

250

250

250

250

250

250

250

250

220-240v,

220-240v,

220-240v,

220-240v,

220-240v,

220-240v,

220-240v,

220-240v,

220-240v,

50hz

50hz

50hz

50hz

50hz

50hz

50hz

50hz

50hz

Phase

single

single

single

single

single

single

single

single

single

model

running current (a) heating

0.42

0.42

0.44

0.53

0.63

0.90

1.04

1.36

1.94

PeFy-P20-32vma-e

cooling

0.53

0.53

0.55

0.64

0.74

1.01

1.15

1.47

2.05

Fuse rating (bs88) - hrc (a)

6

6

6

6

6

6

6

6

6

mains cable no. cores

3

3

3

3

3

3

3

3

3

weight (kg) dimensions (mm)

electrical suPPly

Page 214

PeFy-P40-50vma-e PeFy-P63-80vma-e PeFy-P100-125vma-e

a

b

c

d

700 754 800 660 900 954 1000 860 1100 1154 1200 1060 1400 1454 1500 1360

e 7 9 11 14

F

PeFy-P-vma-e

external static Pressure (Pa) - lo-mi1-mi2-mi3-hi 35-50-70-100-150 35-50-70-100-150 35-50-70-100-150 35-50-70-100-150 35-50-70-100-150 35-50-70-100-150 35-50-70-100-150 35-50-70-100-150 35-50-70-100-150

g

600 658 800 858 1000 1058 1300 1358

Page 215


Dimensions

High Static Pressure Ceiling Concealed Ducted Indoor Unit With improved design flexibility as a result of increased external static pressure, the PEFY-P-VMH-E allows authentic duct air conditioning within the strictest aesthetic confines. I

external static pressure of up to 260Pa

I

greater flexibility for duct extension, branching air outlet configuration

I

reduced noise levels thanks to the use of newly designed centrifugal fan

I

duct can be connected to intake side

I

drain lift-pump (option) 550mm of lift

I

cooling operation set temperature can be set down to 14ยบc db

PEFY-P80, 100, 125, 140VMH-E upper view

>

side view

>

side view

>

city multi Range

PeFy-P-vmh-e

Technical Information PEFY-P-VMH-E - INDOOR UNITS PEFY-P80VMH-E

PEFY-P100VMH-E

PEFY-P125VMH-E

PEFY-P140VMH-E

PEFY-P250VMH-E

heating (nominal)

10.0

12.5

16.0

18.0

31.5

cooling (nominal)

9.0

11.2

14.0

16.0

28.0

hP heating (uK)

10.0

12.5

16.0

18.0

31.5

coP P heating (uK)

9.4

11.7

15.0

16.8

29.5

cooling (uK)

8.5

10.6

13.3

15.2

26.5

high sensible

cooling (uK)

6.5

8.1

10.2

11.6

20.3

shF

(uK)

0.74

0.80

0.74

0.74

0.75

high sensible

(uK)

caPacity (kw)

0.83

0.91

0.81

0.82

0.84

Power inPut (kw) heating (nominal)

0.32

0.48

0.48

0.48

1.23

cooling (nominal)

0.32

0.48

0.48

0.48

1.23

18-25

26.5-38.0

26.5-38.0

28-40

72

100-150-200

100-150-200

100-150-200

100-150-200

130-260

38-43

38-44

38-44

38-44

52 (130Pa)

50

70

70

70

100

width

1000

1200

1200

1200

1250

depth

900

900

900

900

1120

height

380

380

380

380

470

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

380-415v, 50hz

single

single

single

single

3

heating

1.47

2.34

2.34

2.35

2.0

cooling

1.47

2.34

2.34

2.35

2.0

Fuse rating (bs88) - hrc (a)

6

6

6

6

6

mains cable no. cores

3

3

3

3

5

airFlow (m3/min)

lo-hi

external static Pressure (Pa) - lo-mi-hi noise (dba) (150Pa) lo-hi weight (kg) dimensions (mm)

electrical suPPly Phase running current (a)

Page 216

PEFY-P250VMH-E upper view

>

PeFy-P-vmh-e

model reFerence

Page 217


Dimensions

Ceiling Suspended Indoor Unit

PCFY-P40VKM-E 51 2

960

2

853

5

indoor unit designed for direct ceiling suspension

I

Flush to wall installation for concealment of service connections

I

drain piping can be connected from left or right

>

254

476

680

57

lower view

> 236

I

side view

10

230

>

84 88

Front view

195

Designed for ultra-quiet operation and easy maintenance, the unit provides comfortable air conditioning for a wide range of applications where floor or wall space cannot be used practically.

city multi Range

PcFy-P-vKm-e

182

85

878

PCFY-P63VKM-E 51 1280

2

2

>

230

236

5

> 680

57

lower view

side view

10

1173

195

>

84 88

Front view

254

476

Technical Information PCFY-P-VKM-E - INDOOR UNITS

4.5

7.1

11.2

14.0

hP heating (uK)

5.0

8.0

12.5

16.0

coP P heating (uK)

4.7

7.5

11.7

15.0

cooling (uK)

4.3

6.7

10.6

13.3

high sensible

cooling (uK)

3.3

5.2

8.1

10.2

shF

(uK)

0.72

0.72

0.70

0.69

high sensible

(uK)

0.79

0.77

0.75

0.75

Power inPut (kw)

heating (nominal)

0.04

0.05

0.09

0.11

cooling (nominal)

0.04

0.05

0.09

0.11

airFlow (m3/min)

lo-mi1-mi2-hi

10-11-12-13

14-15-16-18

21-24-26-28

21-24-27-31

noise (dba)

lo-mi1-mi2-hi

29-32-34-36

31-33-35-37

36-38-41-43

36-39-42-44

24

32

36

38

width

960

1280

1600

1600

depth

680

680

680

680

height

230

230

230

230

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

weight (kg) dimensions (mm)

electrical suPPly Phase

single

single

single

single

heating

0.28

0.33

0.65

0.76

cooling

0.28

0.33

0.65

0.76

Fuse rating (bs88) - hrc (a)

6

6

6

6

mains cable no. cores

3

3

3

3

running current (a)

Page 218

85

PCFY-P100, 125VKM-E Front view

>

51 2

1600 1493

2

10 5

lower view

side view

>

> PcFy-P-vKm-e

cooling (nominal)

182 1198

236

16.0

84 88 195 230

PCFY-P125VKM-E

12.5

57

PCFY-P100VKM-E

8.0

680

PCFY-P63VKM-E

5.0

476

PCFY-P40VKM-E heating (nominal)

caPacity (kw)

254

model reFerence

182

85

1518

Page 219


Dimensions

Wall Mounted Indoor Units

PKFY-P15, 20, 25VBM-E

An elegant design combined with compact dimensions and quiet operation make the PKFY-P an ideal unit choice. Noise levels are significantly reduced thanks to a unique airflow passage design that not only makes the unit one of the quietest in the industry, but also suppresses condensation and prevents mixing with secondary air. I

compact flat panel design - only 815mm wide (vbm-e)

I

Front grille opening for easy cleaning

I

Front power supply for easy wiring after installation

I

5-way piping provides more flexibility in selection of installation sites

Front view

>

right side view

>

right side view

>

city multi Range

PKFy-P-vbm-e/vhm-e/vKm-e

PKFY-P32, 40, 50VHM-E

Front view

Technical Information

>

PKFY-P-VBM-E / VHM-E / VKM-E - INDOOR UNITS model reFerence

PKFY-P15VBM-E PKFY-P20VBM-E PKFY-P25VBM-E PKFY-P32VHM-E PKFY-P40VHM-E PKFY-P50VHM-E PKFY-P63VKM-E 1.9

2.5

3.2

4.0

5.0

6.3

8.0

cooling (nominal)

1.7

2.2

2.8

3.6

4.5

5.6

7.1

hP heating (uK)

1.9

2.5

3.2

4.0

5.0

6.3

8.0

coP P heating (uK)

1.8

2.3

3.0

3.7

4.7

5.9

7.5

cooling (uK)

1.6

2.1

2.7

3.4

4.3

5.3

6.7

high sensible

cooling (uK)

1.2

1.6

2.0

2.6

3.3

4.1

5.2

shF

(uK)

0.75

0.71

0.70

0.76

0.74

0.72

0.78

high sensible

(uK)

0.83

0.75

0.80

0.85

0.82

0.78

0.85

Power inPut (kw)

heating (nominal)

0.04

0.04

0.04

0.03

0.03

0.03

0.04

cooling (nominal)

0.04

0.04

0.04

0.04

0.04

0.04

0.05

55

688

5

249

155 898

lo-mi1-mi2-hi

4.9-5.0-5.2-5.3

4.9-5.2-5.6-5.9

4.9-5.2-5.6-5.9

9-10-11

9-10.5-11.5

9-10.5-12

16-20

noise (dba)

lo-mi1-mi2-hi

29-31-32-33

29-31-34-36

29-31-34-36

34-37-41

34-38-41

34-39-43

39-45

10

10

10

13

13

13

21

width

815

815

815

898

898

898

1170

depth

225

225

225

249

249

249

295

height

295

295

295

295

295

295

365

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

single

single

single

single

single

single

single

0.20

0.20

0.20

0.30

0.30

0.30

0.30

weight (kg) dimensions (mm)

electrical suPPly Phase running current (a)

heating cooling

>

right side view

>

74

(855)

241

295

5

1170 0.20

0.20

0.20

0.40

0.40

0.40

0.37

Fuse rating (bs88) - hrc (a)

6

6

6

6

6

6

6

mains cable no. cores

3

3

3

3

3

3

3

Page 220

Front view

365

airFlow (m3/min)

PKFY-P63VKM-E

Page 221

PKFy-P-vbm-e / PKFy-P-vhm-e / PKFy-P-vKm-e

heating (nominal)

295

caPacity (kw)


Floor Standing Concealed Indoor Unit

PFFY-P20, 25, 32, 40, 50, 63VLRM-E

A compact concealed unit providing simple, effective air conditioning in perimeter zones. The unit is easy to install and at only 220mm deep offers an unobtrusive method of delivering highly efficient air-conditioning performance. I

concealed unit for hidden installation

I

ideal for perimeter refurbishments

I

cooling operation set temperature can be set down to 14ยบc db

upper view

Front view

>

>

city multi Range

PFFy-P-vlrm-e

Dimensions

Technical Information PFFY-P-VLRM-E - INDOOR UNITS PFFY-P50VLRM-E PFFY-P63VLRM-E

PFFY-P20VLRM-E

PFFY-P25VLRM-E

PFFY-P32VLRM-E

PFFY-P40VLRM-E

heating (nominal)

2.5

3.2

4.0

5.0

6.3

8.0

cooling (nominal)

2.2

2.8

3.6

4.5

5.6

7.1

hP heating (uK)

2.5

3.2

4.0

5.0

6.3

8.0

coP P heating (uK)

2.3

3.0

3.7

4.7

5.9

7.5

cooling (uK)

2.1

2.7

3.4

4.3

5.3

6.7

high sensible

cooling (uK)

1.6

2.0

2.6

3.3

4.1

5.2

shF

(uK)

0.81

0.70

0.74

0.72

0.74

0.73

high sensible

(uK)

0.88

0.80

0.81

0.79

0.80

0.79

Power inPut (kw)

heating (nominal)

0.04

0.04

0.06

0.065

0.085

0.10

cooling (nominal)

0.04

0.04

0.06

0.065

0.085

0.10

caPacity (kw)

airFlow (m3/min)

lo-hi

5.5-6.5

5.5-6.5

7-9

9-11

12-14

12-15.5

noise (dba)

lo-hi

34-40

34-40

35-40

38-43

38-43

40-46

18.5

18.5

20

21

25

27

width

886

886

1006

1006

1246

1246

depth

220

220

220

220

220

220

height

639

639

639

639

639

639

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

single

single

single

single

single

single

heating

0.19

0.19

0.29

0.32

0.40

0.46

cooling

0.19

0.19

0.29

0.32

0.40

0.46

Fuse rating (bs88) - hrc (a)

6

6

6

6

6

6

mains cable no. cores

3

3

3

3

3

3

weight (kg) dimensions (mm)

electrical suPPly Phase running current (a)

Page 222

side view

>

PFFy-P-vlrm-e

model reFerence

Page 223


Dimensions

Floor Standing Concealed Indoor Unit

PFFY-P20, 25, 32, 40, 50, 63VLRMM-E

A compact concealed unit providing simple, effective air conditioning in perimeter zones. The unit is easy to install and at only 220mm deep offers an unobtrusive method of delivering highly efficient air-conditioning performance. I

reduced noise levels compared to the PFFy-P-vlrm-e version

I

cooling operation set temperature can be set down to 14ยบc db

I

static pressure. the new unit has 3 static pressure settings - 20/40/60Pa ideal for ducting in the perimeter zone

I

concealed unit for hidden installation. the unit can be hidden behind a wardrobe in a hotel, then ducted above and below the wardrobe doors. this offers lower noise, less disruption and a low visual impact

upper view

Front view

>

city multi Range

PFFy-P-vlrmm-e

>

Technical Information PFFY-P-VLRMM-E - INDOOR UNITS caPacity (kw)

PFFY-P20VLRMM-E

PFFY-P25VLRMM-E

PFFY-P32VLRMM-E

PFFY-P40VLRMM-E

PFFY-P50VLRMM-E

PFFY-P63VLRMM-E

heating (nominal)

2.5

3.2

4.0

5.0

6.3

8.0

cooling (nominal)

2.2

2.8

3.6

4.5

5.6

7.1

hP heating (uK)

2.5

3.2

4.0

5.0

6.3

8.0

coP P heating (uK)

2.3

3.0

3.7

4.7

5.9

7.5 6.7

cooling (uK)

2.1

2.7

3.4

4.3

5.3

high sensible

cooling (uK)

1.6

2.0

2.6

3.3

4.1

5.2

shF

(uK)

0.81

0.70

0.74

0.72

0.74

0.73

high sensible

(uK)

0.88

0.80

0.81

0.79

0.80

0.79

Power inPut (kw)

heating (nominal)

0.04

0.04

0.04

0.05

0.05

0.07

cooling (nominal)

0.04

0.04

0.04

0.05

0.05

0.07

4.5-5.5-6.5

4.5-5.5-6.5

6.5-7.5-9

8-9.5-11

10-12-14

11-13-15.5

external static Pressure (Pa) lo-mi-hi

20-40-60

20-40-60

20-40-60

20-40-60

20-40-60

20-40-60

noise (dba) (20Pa)

31-36-40

31-36-40

27-32-37

30-36-40

32-37-41

35-40-44

18.5

18.5

20

21

25

27

width

886

886

1006

1006

1246

1246

depth

220

220

220

220

220

220

height

639

639

639

639

639

639

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

Phase

single

single

single

single

single

single

running current (a) heating

0.34

0.34

0.38

0.43

0.48

0.59

cooling

0.34

0.34

0.38

0.43

0.48

0.59

Fuse rating (bs88) - hrc (a)

6

6

6

6

6

6

mains cable no. cores

3

3

3

3

3

3

airFlow (m3/min)

lo-mi-hi

lo-mi-hi

weight (kg) dimensions (mm)

electrical suPPly

Page 224

side view

>

PFFy-P-vlrmm-e

model reFerence

Page 225


Dimensions

Floor Standing Exposed Indoor Unit

PFFY-P20,25,32,40,50,63VLEM-E

A compact cased unit providing simple, effective air conditioning in perimeter zones. The unit is easy to install, and at only 220mm deep offers an unobtrusive method of delivering a highly efficient air-conditioning performance. I

remote controller can be incorporated into the main unit

I

cooling operation set temperature can be set down to 14ยบc db

upper view

Front view

>

>

city multi Range

PFFy-P-vlem-e

Technical Information PFFY-P-VLEM-E - INDOOR UNITS PFFY-P20VLEM-E

PFFY-P25VLEM-E

PFFY-P32VLEM-E

PFFY-P40VLEM-E

heating (nominal)

2.5

3.2

4.0

5.0

6.3

8.0

cooling (nominal)

2.2

2.8

3.6

4.5

5.6

7.1

hP heating (uK)

2.5

3.2

4.0

5.0

6.3

8.0

coP P heating (uK)

2.3

3.0

3.7

4.7

5.9

7.5

cooling (uK)

2.1

2.7

3.4

4.3

5.3

6.7

high sensible

cooling (uK)

1.6

2.0

2.6

3.3

4.1

5.2

shF

(uK)

0.81

0.70

0.74

0.72

0.74

0.73

high sensible

(uK)

0.88

0.80

0.81

0.79

0.80

0.79

Power inPut (kw)

heating (nominal)

0.04

0.04

0.06

0.065

0.085

0.10

cooling (nominal)

0.04

0.04

0.06

0.065

0.085

0.10

caPacity (kw)

PFFY-P50VLEM-E PFFY-P63VLEM-E

airFlow (m3/min)

lo-hi

5.5-6.5

5.5-6.5

7-9

9-11

12-14

12-15.5

noise (dba)

lo-hi

34-40

34-40

35-40

38-43

38-43

40-46

23

23

25

26

30

32

width

1050

1050

1170

1170

1410

1410

depth

220

220

220

220

220

220

height

630

630

630

630

630

630

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

single

single

single

single

single

single

heating

0.19

0.19

0.29

0.32

0.40

0.46

cooling

0.19

0.19

0.29

0.32

0.40

0.46

Fuse rating (bs88) - hrc (a)

6

6

6

6

6

6

mains cable no. cores

3

3

3

3

3

3

weight (kg) dimensions (mm)

electrical suPPly Phase running current (a)

Page 226

side view

>

PFFy-P-vlem-e

model reFerence

Page 227


Dimensions

Floor Standing Exposed Indoor Unit

PFFY-P20,25,32,40VKM-E

The PFFY-P-VKM-E series is extremely versatile and is designed for wall attached installation at floor level. The auto swing vane provides a more natural and comfortable airflow throughout the room and the lightweight, compact design makes installation easy. I

Pure white, slimline design

I

upper and lower vanes for optimum, powerful and efficient air distribution

upper view

>

Front view

>

city multi Range

PFFy-P-vKm-e

Technical Information PFFY-P-VKM-E - INDOOR UNITS PFFY-P20VKM-E

PFFY-P25VKM-E

PFFY-P32VKM-E

PFFY-P40VKM-E

heating (nominal)

2.5

3.2

4.0

5.0

cooling (nominal)

2.2

2.8

3.6

4.5

hP heating (uK)

2.5

3.2

4.0

5.0

coP P heating (uK)

2.3

3.0

3.7

4.7

cooling (uK)

2.1

2.7

3.4

4.3

high sensible

cooling (uK)

1.6

2.0

2.6

3.3

shF

(uK)

0.81

0.74

0.71

0.70

high sensible

(uK)

0.88

0.85

0.77

0.76

Power inPut (kw)

heating (nominal)

0.025

0.025

0.025

0.028

cooling (nominal)

0.025

0.025

0.025

0.028

caPacity (kw)

airFlow (m3/min)

lo-mi1-mi2-hi

5.9-6.8-7.6-8.7

6.1-7.0-8.0-9.1

6.1-7.0-8.0-9.1

8.0-9.0-9.5-10.7

noise (dba)

lo-mi1-mi2-hi

27-31-34-37

28-32-35-38

28-32-35-38

35-38-42-44

15

15

15

15

width

700

700

700

700

depth

200

200

200

200

height

600

600

600

600

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

single

single

single

single

heating

0.20

0.20

0.20

0.24

cooling

0.20

0.20

0.20

0.24

Fuse rating (bs88) - hrc (a)

6

6

6

6

mains cable no. cores

3

3

3

3

weight (kg) dimensions (mm)

electrical suPPly Phase running current (a)

Page 228

side view

>

PFFy-P-vKm-e

model reFerence

Page 229


Dimensions

Lossnay Outdoor Air Processing Indoor Unit

GUF-50/100RD3

The GUF-50RD3 and GUF-100RD3 outdoor air processing units can be used with any of the extensive range of City Multi indoor units to provide ventilation, dust removal, humidification and heat recovery.

side view

I

a combination of a lossnay & city multi indoor in a single unit

I

air temperature in any room can be adjusted to the desired temperature via this unit which is used as an indoor unit of the city multi air conditioning system

I

the ventilating and air conditioning functions are integrated in a single unit, saving space and installation costs

I

heat recovery helps to save energy - a benefit that’s not only good for the environment, but also great for cutting energy costs

I

Free cooling is also available should outdoor conditions be suitable

>

upper view

city multi Range

guF-rd3

>

Technical Information OUTDOOR AIR PROCESSING INDOOR UNITS model reFerence caPacity (kw)

GUF-50RD3

GUF-100RD3

heating (nominal)

6.42 (2.25)

13.00 (4.70)

cooling (nominal)

5.29 (1.66)

10.81 (3.49)

hP heating (uK)

6.42 (2.25)

13.00 (4.70)

coP P heating (uK)

5.93 (2.08)

12.01 (4.34)

cooling (uK)

5.03 (1.58)

10.27 (3.32)

Power inPut (kw) airFlow (m3/h)

lo-hi

external static Pressure (Pa) noise (dba)

0.505

400-500

800-1000

140

140

lo-hi

33.5-34.5

38-39

54

92

width

1016

1231

depth

1288

1580

height

317

398

220-240v, 50hz

220-240v, 50hz

weight (kg) dimensions (mm)

0.265

electrical suPPly Phase

single

single

0.70-1.15

1.73-2.20

Fuse rating (bs88) - hrc (a)

6

6

mains cable no. cores

3

3

running current (a)

attention

lo-hi

Front view

>

1. nominal condition: Cooling/Heating capacity indicates the value of operation under the following air condition and above air volume. Cooling: Indoor 27ºC DB/19.5ºC WB, Outdoor 35ºC DB/24ºC WB. Heating: Indoor 21ºC DB/14.6ºC WB, Outdoor 7ºC DB/6ºC WB. 2. uK condition: Summer: Indoor 21ºC, Outdoor 27ºC Winter: Indoor 21ºC, Outdoor -1ºCWB

guF-rd3

3. The figures in ( ) indicates the heat recovery at Lossnay core. 4. The current, input and efficiency are based on the above air volume. 5. The air nozzle noise (45º angle 1.5m ahead) is about 6dB greater than the indicated value. (High notch). 6. Specifications may be subject to change without notice.

Page 230

Page 231


Dimensions

VRF Heat Pump Boiler

PWFY-P100VM-E-BU upper view

> 205 (Mounting pitch) 300

the mitsubishi electric booster unit (PwFy-P100vm-e-bu) can achieve a flow temperature of 70ºC and is an ideal solution for providing a hot water supply to commercial buildings in an energy efficient manner. Heat pump technology works by extracting heat from the air and upgrading it to heat a building. This process in itself is energy efficient, however we can take this a step further by using heat recovery. Heat recovery technology taps into and utilises otherwise wasted heat energy, extracted from areas of a building that require cooling, providing heating for hot water almost for free. Recovering the heat in this manner maximises the efficiency of the system all year round, therefore increasing energy savings and lowering running costs. Taking full advantage of heat recovery technology, the 12.5kW PWFY booster unit upgrades the heat pump energy to higher temperatures required to achieve 70ºC water temperatures. This is possible using the first ever VRF cascade refrigeration system between R410A and R134a refrigerant. The benefit of having air conditioning as well as a hot water supply from a single system means that the unit is suitable for a variety of applications. Offices, hotels, gyms, restaurants etc are typical examples of buildings that already have an air conditioning system in place. Providing the essential hot water supply to these applications is a simple addition of the booster unit to the existing air conditioning system. It is a perfect solution that allows inconveniences that arise when installing gas boilers such as gas grid connection costs, meter installation and maintenance costs to be eliminated. Further there is a reduction in running costs and carbon emissions due to the high efficiency of these units over gas boilers.

450 500 (Mounting pitch) 525

Front view

I

> Water outlet (RC3/4 screw)

35

Control box

46

Connection pipe of outdoor unit (Gas) ø15.88 <Brazed>

60 480 140

800

91

134

Service panel

can be used in conjunction with cmb-Pw202v-J to allow a 200% heat recovery index uses the Par-w21maa controller

80

100

102 165

191

91

Connection pipe of outdoor unit (Liquid) ø9.52 <Brazed>

35

114

55

Technical Information

Water inlet (R3/4 screw)

54

The Mitsubishi Electric air to water heating units (PWFY-P100/200VM-E-AU) can achieve flow temperatures of 45ºC in heating and 10ºC in cooling, making them perfect for application on underfloor heating/cooling systems. I

side view

>

city multi Range

PwFy-P

Drain (R1 screw)

184

PWFY-P100/200VM-E-AU

PWFY-P caPacity

heating (nominal) cooling (nominal) heating (uK)

Power inPut (kw) comPatible outdoor / condensing units

PWFY-P100VM-E-BU

PWFY-P100VM-E-AU

PWFY-P200VM-E-AU

12.5

12.5

25.0

-

11.2

22.4

12.5

10.4

20.8

2.48

0.015

0.015

Pury / PQry

Puhy / PQhy / Pury / PQry

Puhy / PQhy / Pury / PQry

reFrigerant charge (kg) high temp circuit

1.1 (r134a)

-

-

PiPe siZe (mm) (in)

gas

15.88 (5/8")

15.88 (5/8")

19.05 (3/4")

liquid

9.52 (3/8")

9.52 (3/8")

9.52 (3/8")

water

19.05 (3/4”)

19.05 (3/4”)

19.05 (3/4”)

drain

ø32 (1 1/4”)

ø32 (1 1/4”)

ø32 (1 1/4”)

noise (dba)

44

29

29

weight (kg)

60

35

38

upper view

> 205 (Mounting pitch) 300

model reFerence

450 500 (Mounting pitch) 525

Front view

side view

>

> Water outlet (RC3/4 screw) P200:Use the Expansion joint of accessories

Control box 35

46 60 140

Connection pipe of outdoor unit (Gas) P100:ø15.88 <Brazed> P200:ø19.05 <Brazed>

134

480

800

91

depth

300

300

300

height

785 (800)

785 (800)

785 (800)

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

Phase

single

single

single

running current (a)

10.66

0.063

0.063

Fuse rating (bs88) - hrc (a)

25

6

6

mains cable no. cores

3

3

3

water Flow rate m3/h

0.6-2.15

0.6-2.15

1.2-4.3

91

35

electrical suPPly

55

Connection pipe of outdoor unit (Liquid) ø9.52 <Brazed> Water inlet (R3/4 screw) 114

Drain (R1 screw) 206

PwFy-P

450

54

450

191

450

80

width

102 165

dimensions (mm)

100

Service panel

note: The PWFY-P200VM-E-AU will require 2 expansion joints

Page 232

Page 233


Air Curtain System

Dimensions

AIR CURTAIN vrF Phv1000/1500/2000r dxe

In collaboration with Thermoscreens 速, Mitsubishi Electric have developed a range of air curtains that are able to be connected to our City Multi VRF systems, as opposed to the more traditional direct electric method associated with air curtains. I

reduced co2 emissions

I

reduced running costs

I

inverter technology (does not waste energy)

I

range of different sizes to suit every application

I

allows open door policy in retail outlets whilst being energy efficient

I

clean environment - protection from dust, fumes etc

I

comfortable climate for customers

I

easy to install and maintain

I

heat recovery possible, optimising energy use

side view

>

rear view

>

upper view

>

city multi Range

vrF Phv dxe Heat Pump Air Curtain

Technical Information

AIR CURTAIN vrF Phv1000/1500/2000 dxe

model reFerence dimensions (mm) (wxdxh) suPPly (50hz) heat outPut (kw) loading (amps) velocity (m/s)

VRF PHV1000R DXE HO

VRF PHV1500R DXE LO

VRF PHV1500R DXE HO

VRF PHV2000R DXE LO

VRF PHV2000R DXE HO

1150x436x296

1650x436x296

1650x436x296

2240x436x296

2240x436x296

415v*1

415v*1

415v*1

415v*2

415v*2

9

10.6

15.1

16.4

21.4

7.8*1

12.7*1

12.7*1

15.7*2

15.7*2

9

9

9

9.5

9

1400

2500

2600

3300

3130

weight (kg)

45

66

67

85

88

noise db(a) @ 3m

56

58

58

59

59

3.5

3.5

3.5

3.5

air volume (m3/h)

max. mounting height (m) outdoor unit model

Pumy / Puhy / Pury / PQhy / PQry Pumy / Puhy / Pury / PQhy / PQry Pumy / Puhy / Pury / PQhy / PQry Pumy / Puhy / Pury / PQhy / PQry

side view

>

rear view

>

vrF Phv dxe Heat Pump Air Curtain

VRF PHV DXE - RECESSED

3.5 Puhy / Pury / PQhy / PQry

notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load (1.3 amp load for VRF PHV1000R DXE HO) *2 for units with electric heaters disabled, 240v power supply 2.7 amp load.

upper view

VRF PHV DXE - FREE STANDING model reFerence dimensions (mm) (wxdxh) suPPly (50hz) heat outPut (kw) loading (amps) velocity (m/s)

VRF PHV1000 DXE HO

VRF PHV1500 DXE LO

VRF PHV1500 DXE HO

VRF PHV2000 DXE LO

VRF PHV2000 DXE HO

1196x377x255

1746x377x255

1746x377x255

2296x377x255

2296x377x255

415v*1

415v*1

415v*1

415v*2

415v*2

9

10.6

15.1

16.4

21.4

7.8*1

12.7*1

12.7*1

15.7*2

15.7*2

9

9

9

9.5

9

1400

2500

2600

3300

3130

weight (kg)

39

59

60

78

80

noise db(a) @ 3m

56

58

58

59

59

3.75

3.75

3.75

3.75

air volume (m3/h)

max. mounting height (m) outdoor unit model

Pumy / Puhy / Pury / PQhy / PQry Pumy / Puhy / Pury / PQhy / PQry Pumy / Puhy / Pury / PQhy / PQry Pumy / Puhy / Pury / PQhy / PQry

>

3.75 Puhy / Pury / PQhy / PQry

notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load (1.3 amp load for VRF PHV1000 DXE HO) *2 for units with electric heaters disabled, 240v power supply 2.7 amp load.

Page 234

Page 235


Dimensions

Sensible Cooling, Chilled Water Wall Mounted Indoor Unit In collaboration with Thermoscreens ®, Mitsubishi Electric have developed a sensible cooling wall mounted unit that can be connected to our City Multi VRF systems via the PWFY-P200VM-E-AU heat pump boiler. This unit offers 100% sensible cooling (SHF of 1) for use in server rooms and other sensible cooling applications. shF of 1 and capacity validated by 3rd party assessment (bsria)

I

reduced co2 emissions

I

reduced running costs

I

inverter technology (does not waste energy)

I

easy to install and maintain

I

ideal for small to medium size server rooms / laboratories

I

no 3rd party humidifier is required

I

Par-w21maa controller included

I

ideal for heat recovery applications - use with the water system connection box (wcb) on page 240 to achieve full heat recovery potential

side view

>

rear view

>

C. 150min. for pipes

I

INDOOR UNIT vrF Phv2000 nt

295

255

upper view

upper view

>

city multi Range

vrF Phv nt

>

PwFy-P (not included)

Technical Information VRF PHV NT - indoor units 2296

depth

377

height

255

cooling

12.0

shF electrical suPPly Phase loading (a) velocity (m/s) air volume (m3/h) weight (kg) noise (dba) @ 3m water volume Flow rate (m3/h) hydraulic resistance (kPa @ 3.18 m3/h) hydraulic resistance oF PwFy-P200vm-e-au (kPa @ 3.18 m3/h)

1.0 220-240v, 50hz single 2.7 9 2885 90 59 3.18 36 38*1

water volume oF coil (litres)

5.1

water volume oF heat exchanger in PwFy-P200vm-e-au (litres)

2.09

outdoor unit model

36

caPacity (kw)

VRF PHV2000 NT width

Puhy / Pury / PQhy / PQry

vrF Phv nt Sensible Cooling Chilled Water Unit

dimensions (mm)

168

model reFerence

notes: For use with a Mitsubishi Electric PWFY-P200VM-E-AU water cooling unit as part of a VRF system. Water flow temperature from the PWFY-P is to be set to 10ºC (cannot be set lower) Test conditions: 35ºC DB / 27ºC WB outdoor conditions, 24ºC DB / 40% relative humidity indoor conditions - validated by BSRIA tests. *1 Without strainer.

Page 236

Page 237


Dimensions

At the heart of both the R2 and WR2 Series, the BC controller makes simultaneous heating and cooling possible. It has the inherent ‘intelligence’ to be the system’s decision-maker. I I I I

I I I

CMB-P104, 105, 106V-G1 upper view

transferring energy around the system drawing on energy from the heat source units/outdoor units directing energy as requested by the individual indoor units instructs the heat source unit/outdoor unit on the amount of refrigerant (liquid or gas) that is required to achieve the requested cooling or heating requirements allows unique 2-pipe heat recovery application hic circuit for improved efficiency new brazed connections

>

side view

>

cmb-P104v-g1 cmb-P105v-g1 cmb-P106v-g1

a

b

3 4 5

180 240 300

CMB-P108, 1010, 1013, 1016V-GA1/HA1 Technical Information

upper view

>

side view

city multi Range

bc controllers

>

BC CONTROLLERS model reFerence

CMB-P104V-G1

CMB-P105V-G1

number oF connections

4

5

6

weight (kg)

24

27

28

dimensions (mm)

CMB-P106V-G1

width

648

648

648

depth

432

432

432

height

284

284

284

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

Phase

single

single

single

Power inPut (Kw)

0.085

0.104

0.123

running current (a)

electrical suPPly

0.36

0.44

0.52

Fuse rating (bs88) – hrc (a)

6

6

6

mains cable no. cores

3

3

3

cmb-P108v-ga1 cmb-P1010v-ga1 cmb-P1013v-ga1 cmb-P1016v-ga1/ha1

note: CMB-P-V-G1 units are for use with PURY-(E)P200-350 YJM-A & PQRY-P200-300YHM-A units only.

number oF connections weight (kg)

CMB-P108V-GA1

CMB-P1010V-GA1

CMB-P1013V-GA1

CMB-P1016V-GA1

CMB-P1016V-HA1

8

10

13

16

16

43

48

55

62

69

width

1110

1110

1110

1110

1110

depth

520

520

520

520

520

height

289

289

289

289

289

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

Phase

single

single

single

single

single

Power inPut (Kw)

0.161

0.198

0.255

0.312

0.312

running current (a)

0.68

0.83

1.07

1.30

1.30

Fuse rating (bs88) – hrc (a)

6

6

6

6

6

mains cable no. cores

3

3

3

3

3

dimensions (mm)

electrical suPPly

b

7 9 12 15

420 540 720 900

CMB-P104, 108V-GB1

MASTER BC CONTROLLERS model reFerence

a

upper view

>

side view

>

cmb-P104v-gb1 cmb-P108v-gb1

note: CMB-P-V-GA1 units are for use with PURY-(E)P200-650Y(S)JM-A(1) & PQRY-P200-600Y(S)HM-A units only. CMB-P1016V-HA1 unit is for use with PURY-(E)P700-900YSJM-A units only.

a

b

3 7

180 420

SLAVE BC CONTROLLERS CMB-P104V-GB1

CMB-P108V-GB1

CMB-P1016V-HB1

number oF connections

4

8

16

weight (kg)

22

32

55

width

648

648

1098

depth

432

432

432

dimensions (mm)

height

284

284

284

220-240v, 50hz

220-240v, 50hz

220-240v, 50hz

Phase

single

single

single

Power inPut (Kw)

0.076

0.151

0.301

running current (a)

0.32

0.63

1.26

Fuse rating (bs88) – hrc (a)

6

6

6

mains cable no. cores

3

3

3

electrical suPPly

Page 238

CMB-P1016V-HB1 upper view

>

side view

>

bc controllers

model reFerence

Page 239


Following the success of PWFY, this new low cost branch controller allows simple heat recovery between 2 ports, one being heating only with PWFY, the other being heating or cooling with PWFY or standard indoor units. A key factor

Dimensions

CMB-PW202V-J

with the WCB is the ability to allow 200% connectable index to the system. Typically the outdoor unit of a system is sized to match the internal load. For a communications room there is a continuous cooling load and under normal circumstances all the heat is wasted to the outside.

upper view

>

By utilising a WCB, a system can be sized for the cooling load of a communications room and then use the delivery of cold water from a PWFY to achieve this. The system can then benefit from full heat recovery of up to 200% by connecting a second PWFY in heating mode that can deliver sanitary hot water or hot water for space heating elsewhere in the building. I

total heat recovery, transferring all energy around the system

I

200% connectable heat recovery index for optimum efficiency, flexibility and cost savings (130% when connecting with standard indoor units)

I

energy saving mode available (longer heat up time, but with a 15% coP improvement on standard control)

I

installation cost and time savings

I

connectable to both bu and au PwFy models

city multi Range

water system connection box (wcb)

Technical Information WCB model reFerence

>

Pury-(e)P200-350yJm-a / PQry-P200-300yhm-a

weight (kg)

20

dimensions (mm)

width

648

depth

432

height

284

electrical suPPly

220-240v, 50hz

Phase

single

Power inPut (Kw)

0.024

running current (a)

0.10

Fuse rating (bs88) – hrc (a)

6

mains cable no. cores

3

example 1:

side view

CMB-PW202V-J

comPatible outdoor / condensing units

200% connection with continual heating only and cooling only Ports PwFy-P200au (heating) to underfloor heating

Front view

> water connection box (wcb)

outdoor heat recovery unit (size 200)

PwFy-P200au (cooling) to third party comms room unit

wcb

example 2:

130% connection with hot water and cooling/heating indoor units note: 100% if only in heating

outdoor heat recovery unit (size 200)

wcb

Page 240

PwFy-P100bu (hot water) to tank

3 x PeFy-P50vma (cooling/heating) restaurant

Page 241


Air Handling Unit Controller outdoor units

Mitsubishi Electric City Multi outdoor units can be used with this interface box, creating and ideal solution when a unique air handling unit is required. The Air Handling Unit Controllers are supplied with LEV expansion device(s). I I I I I

discharge or return air temperature control temperature set point by control 0-10vdc auto mode available for ease of application error input iP2x rated (only for internal use)

Technical Information

4-way blow cassette units

PAC-AH-M-J - AHU CONTROLLER model reFerence air handling unit siZe allowed heat exchanger caPacity (kw) - heating allowed heat exchanger caPacity (kw) - cooling

PAC-AH125M-J

PAC-AH125M-J

PAC-AH140M-J

PAC-AH250M-J

PAC-AH250M-J

PAC-AH500M-J

P100

P125

P140

P200

P250

P400*2

PAC-AH500M-J P500*2

10.0 - 12.5

12.5 - 16.0

16.0 - 18.0

18.0 - 25.0

25.0 - 31.5

40.0 - 50.0

50.0 - 63.0

9.0 - 11.2

11.2 - 14.0

14.0 - 16.0

16.0 - 22.4

22.4 - 28.0

36.0 - 45.0

45.0 - 56.0

1500 - 2850

1900 - 3550

2150 - 4050

3000 - 5700

3750 - 7100

6000 - 11400

7500 - 14200

reFerence air Flow rate (m3/h)*3

2000

2500

3000

4000

5000

8000

10000

standard evaPorator Path number*1

4 - 5

4 - 5

5 - 6

6 - 10

8 - 10

16 - 20

16 - 20

allowed heat exchanger volume (cm3)

dimensions (mm)

width

328

328

328

328

328

328

328

( ) = inc mountings

depth

104 (122)

104 (122)

104 (122)

104 (122)

104 (122)

104 (122)

104 (122)

height

378 (420)

378 (420)

378 (420)

378 (420)

378 (420)

378 (420)

378 (420)

5

5

5

5

5

5

5

gas

15.88(5/8”)

15.88(5/8”)

15.88(5/8”)

19.05(3/4”)

22.22(7/8”)

28.58(1 1/8”)

28.58(1 1/8”)

liquid

9.52(3/8”)

9.52(3/8”)

9.52(3/8”)

9.52(3/8”)

9.52(3/8”)

12.7(1/2”)

15.88(5/8”)

weight (kg) PiPe siZe mm(in)

note: One air handling unit controller is required per air handling unit. Saturated refrigerant temperature at exit of evaporator = 8.5ºC, SH = 5K, liquid temperature = 25ºC, air = 27ºCDB/19ºCWB *1 When the diameter of the heat exchanger tube is ø9.52. *2 P400 and P500 are not compatible with PURY and PQRY. *3 If using in combination with standard indoor units, then these figures do not apply.

2-way blow cassette units

1-way blow cassette units ceiling concealed ducted units

aPPlicable outdoor units Puhy-P y(s)Jm-a Puhy-eP y(s)Jm-a Puhy-hP y(s)Hm-a Puhy-rP y(s)Jm-b PQhy-P y(s)Hm-a

Pury-P y(s)Jm-a Pury-eP y(s)Jm-a Pury-rP yJm-b PQry-P y(s)Hm-a

bc controllers

indoor units

example: air handling unit controller (mitsubishi electric)

PLP-6BA SLP-2AAW PLP-6BALM PLP-6BAJ PAC-SA1ME-E PAR-SA9FA-E S70E40714

- Grille for PLFY-P-VBM-E - Grille for PLFY-P-VCM-E2 - Grille and infra-red controller for PLFY-P-VBM-E - Grille with filter lowering function for PLFY-P-VBM-E - ‘I -See Sensor’ corner panel for PLFY-P-VBM-E - Infra-red signal receiver for PLFY-P-VBM-E - Infra-red Controller (PAR-SL97A-E) for PLFY-P-VBM-E

CMP-40VLW-C CMP-63VLW-C CMP-100VLW-C CMP-125VLW-C PAC-KH11OF

-

PMP-40BMW

- Grille for PMFY-P-VBM-E

PAC-KE04DM-F PAC-KE88LAF PAC-KE89LAF PAC-KE85LAF PAC-KE80TB-F PAC-KE140TB-F PAC-KE250TB-F

-

CMY-R160-J1 CMY-S202-J

- Joint pipe - Cover cap for CMB-PW202V-J

PAC-SE41TS-E

- Remote sensor

PAR-W21MAA THERM-10M

- Controller - Thermistor (10m cable)

Grille for PLFY-P20-40VLMD-E Grille for PLFY-P50-63VLMD-E Grille for PLFY-P80-100VLMD-E Grille for PLFY-P125VLMD-E OA duct flange for PLFY-P20-100VLMD-E

Drain lift-up mechanism for PEFY-P-VMH-E Long life filter for PEFY-P80VMH-E Long life filter for PEFY-P100-140VMH-E Long life filter for PEFY-P250VMH-E Filter box for PEFY-P80VMH-E (necessary when long life filter is used) Filter box for PEFY-P100-140VMH-E (necessary when long life filter is used) Filter box for PEFY-P250VMH-E (necessary when long life filter is used)

controller (field supplied)

vrF heat Pump boilers 220-240v, 50hz Power supply

m-net wiring

- Branch Pipe (Joint) for size 200 or below - total capacity of indoor units - Branch Pipe (Joint) for size 201-400 - total capacity of indoor units - Branch Pipe (Joint) for size 401-650 - total capacity of indoor units or first branch of (E)P450-P650 - Branch Pipe (Joint) for size 651 or above - total capacity of indoor units or first branch of P700-P1250 / EP700-EP900 - Branch Pipe for 2 branches (PUMY) - Twinning Kit for PUHY-P500-650YSJM-A / PUHY-EP400-600YSJM-A / PUHY-HP400-500YSHM-A / PQHY-P400-600YSHM-A - Twinning Kit for PUHY-P700-900YSJM-A CMY-Y200VBK2 - Twinning Kit for PUHY-P950-1250YSJM-A / PUHY-EP650-900YSJM-A / PQHY-P650-900YSHM-A CMY-Y300VBK2 - Twinning Kit for PUHY-RP400-650YSJM-B CMY-RP100VBK - Twinning Kit for PUHY-RP700-900YSJM-B CMY-RP200VBK - Twinning Kit for PURY-P450-650YSJM-A(1) / PURY-EP400-600YSJM-A CMY-R100VBK - Twinning Kit for PURY-P700-800YSJM-A CMY-R200VBK CMY-R100XLVBK - Twinning Kit for PURY-EP650-700YSJM-A CMY-R200XLVBK - Twinning Kit for PURY-P850-900YSJM-A - Twinning Kit for PQRY-P400-600YSHM-A CMY-Q100VBK - PQFY Auto-Changeover controller ACH1 - VRF AHU Interface (for use with 24v AC signals) ACH2 PAC-CN32WHMC-UK - Energy monitoring connector CMY-Y102S-G2 CMY-Y102L-G2 CMY-Y202-G2 CMY-Y302-G2 CMY-Y62-G-E CMY-Y100VBK2

air handling unit controllers / accessories

The Air Handling Unit Controller is an interface to allow connection to third party manufacturer equipment.

acoustic Kits for PUHY and PURY Series units

thermistor wiring

A range of Acoustic Kits designed for noise reduction. An industry first, the kits offer a 8dBA noise level reduction from standard.

Piping

For supply and / or installation please contact outdoor unit (mitsubishi electric)

Page 242

air handling unit (field supplied)

city multi Range

accessories / optional extras

Pac-ah-m-J

ambient acoustics on 01934 712802 Page 243


Lossnay Total Heat Exchangers

Air Conditioning Commercial Heating Domestic Heating Photovoltaics


Simple and Effective

Stale exhaust air

Heat exchange unit (Lossnay core)

Fresh air from outside

Excellent Air Quality and Unbeatable Heat Exchange Efficiency

Stale room air extracted

The Secret of the Lossnay System

Fresh air supply to the room

Poor air quality can be attributed to many problems arising in the workplace or in the home. It is believed to contribute to a significant loss in productivity, low morale and higher rates of sickness amongst many employees. The object of providing good ventilation alongside air conditioning in residential and commercial buildings is to provide conditions under which people can live and work in comfort and safety. Developed and refined over the past 35 years, the Lossnay system has perfected the recovery of energy that would have otherwise been wasted. The units reduce overall energy costs by extracting stale air and then recovering the heating or cooling energy to either warm or cool incoming fresh air. By utilising this energy, the Lossnay system can save up to 30% on initial capital costs of heating and cooling plant by reducing the load of the occupied space, resulting in the need for a smaller heating and/or cooling system.

The secret of the Lossnay system lies in the cross flow, plate fin structure of the heat exchange unit. A diaphragm made of specially processed paper fully separates inlet and exhaust air supplies, ensuring that only fresh air is introduced to the indoor environment.

Outdoors Stale dirty indoor air (Exhaust Air)

Indoors Fresh air into building (Supply Air)

Improvements to the Lossnay The microscopically small pores of the diaphragm have been made even smaller, decreasing the rate at which water soluble gases such as Ammonia and Hydrogen pass through. Further, a new specially processed paper used to make the diaphragm has been developed with high moisture permeability characteristics. This aids in the transfer of moisture and improves the effectiveness of shielding unwanted gases, resulting in highly efficient energy transfer.

Page 246

Fresh air introduction (Outdoor Air)

Stale air removed from building (Return Air)

Page 247


Main Features of

Total Heat Recovery Concept

Lossnay Effective Ventilation Lossnay’s simultaneous air exhaust/supply provides effective ventilation. Conventional ventilators (i.e. extract propeller fans) do not work effectively within air tight buildings because of the negative air pressures involved.

Good Energy Recovery

Good Sound Attenuation

Total heat (sensible and latent) recovery provides a comfortable air temperature within the room. The energy saved by using Lossnay contributes towards lowering the heating or cooling requirement within the building, therefore reducing the energy requirement and running costs.

As the Lossnay core is made of paper and the permeable holes are small, the Lossnay core provides outstanding soundproofing properties and is appropriate for sound proof rooms.

Free Cooling “By-pass” Function (LGH series) When the outdoor temperature is lower than the indoor air conditioned temperature in the summer, Lossnay provides fresh outdoor cool air to reduce the indoor air temperature.

Part L2 Building Regulations With the introduction of Part L2 (Part J in Scotland), new building design is changing to become more airtight, as well as energy efficient. The need for fresh air has remained the same however and thus poses new challenges for modern design. Lossnay fully meets these challenges due to its basic principal and its efficient heat recovery.

Operation in winter

Operation in summer

4°C

25.6°C

Stale warm air (exhaust)

Stale cool air (exhaust)

16°C

22.4°C

Fresh warm air (indoor supply air)

Fresh cool air (indoor supply air)

0°C

20°C

Fresh cool air (outdoor air)

Stale warm air (indoor air)

Heating unit

27°C

21°C

Fresh hot air (outdoor air)

Stale cool air (indoor air)

Cooling unit

Using a Lossnay LGH-100RX5 in the winter example above, 8.2kW of heat is recovered per hour from the extracted air.

Page 248

Page 249


Lossnay Working in Conjunction with Air Conditioning Lossnay units can work either on their own to provide fresh air into a room, or in combination with Mr Slim or City Multi ceiling cassettes and ducted units. When working together with air conditioning, Lossnay units can provide significant energy savings by automatically utilising free cooling as well as heat recovery. As the Lossnay and the air conditioning unit are connected by a two core communication cable, they can work together to optimise both comfort and energy efficiency. This is done by the Lossnay reading the mode and set temperature the air conditioning requires, then utilising the outside temperature to help achieve the required temperature either by free cooling or heat recovery.

Free Cooling was available in London over 58% of the time in 2006

When using Lossnay in conjunction with air conditioning the heating and cooling loads can be reduced significantly, reducing the running costs by up to 30% compared with air conditioning systems without heat recovery systems.

Above example: One LGH25RX5 serving one PLA-RP71BA. Room size 7m x 7m, 140w/m2 heat load. 7 people per room, 10litres/person of fresh air to meet Part F requirements. Maximum amount of fresh air to be introduced is 30% of the fan coil volume. Ceiling cassettes may require fresh air casements. Free cooling is not available below 8ยบC when interlocked with Mr Slim or City Multi units.

Lossnay fan speed button is incorporated within the standard PAR-30MAA and PAR-F27MEA controllers

Ambient Temperature - London 2006, 8am - 6pm The graph shows the hourly temperature for 2006 in London between 8.00am - 6.00p.m. The point to note is the amount of free cooling available during these hours, as well as the heat recovery below (22% of the time) and cooling recovery above (20% of the time). Lossnay is a year round solution for providing fresh air.

Over 58% of the time between 8am-6pm, the temperature in London was between 8ยบC and 20ยบC, allowing free cooling when the air conditioning setpoint was 21ยบC in cooling mode. If the setpoint is higher, free cooling is increased.

Page 250

Page 251


Hyper Eco Core LGH-RX5-E and LGH-RSDC-E Lossnay units feature the newly developed “Hyper Eco Core”, which uses non-porous, ultra-thin film to achieve high enthalpy exchange efficiency. With a thickness of only 25µm, these are the thinnest in the world and are approximately one fifth the thickness of previous Mitsubishi Electric products. Moisture permeability is dramatically increased and enthalpy heat exchange greatly improved.

Comparison of new and old Lossnay Core cross-sections Previous Lossnay Core

Comparison of material used in Hyper Eco Core (25µm ultra-thin film) with regular paper

New Hyper Eco Core

120µm

25µm

Porous partition plate

Non-porous film partition plate

The thinnest paper used in regular printing is 51µm thick (used in dictionaries) and the material of the Hyper Eco Core is approximately half the thickness of this. Use

Thickness 25µm

Hyper Eco Core material

Multi-Ventilation Mode Enables the appropriate supply/exhaust balance to be selected to suit usage, environment and location. Ventilation Mode

Previous Mitsubishi Electric material 120µm Photocopier paper

Ducts can be connected in two different directions to the outdoor vents thanks to collars and aperture plates that can be interchangeably placed in two different positions.

Standard installation

Installation with duct direction changed Can be installed close to the surface of the wall.

A space is necessary to prevent the influx of rainwater.

Changing the duct direction

Collar

All LGH-RX5-E models feature the "Multi-ventilation Mode," which allows the air supply/exhaust balance to be varied dynamically to suit the usage environment and location. Modes can be selected easily by setting the connectors on the circuit board.

Power air supply/exhaust mode

High

High

Power air supply mode

High

Low

Power air exhaust mode

Low

High

Energy-saving ventilation mode

Low

Low

* "High" can be further set to "Extra high" using the dip switch.

This flexibility allows for installations close to the surface of a wall and helps avoid cases where the stale air exhaust vent would be blocked by an obstruction of some kind. This makes both the planning and installation of Lossnay units that much simpler.

Page 252

51µm

Consists of a specially processed structure based on a single-layer, non-porous, ultra-thin film material. Moisture exchange (water vapour transmission) is promoted by the special film, which increases the affinity for moisture (the thinner the film, the higher the permeability). The non-porous ultra-thin film material acts as a barrier against air leakage.

Connect Ducts in Two Different Directions (Outdoor vents)

Exhaust Airflow

100µm

Dictionary paper

Consists of a two-layer construction using a specially processed material made of a preferential permeable film on a porous base material. This provides moisture permeability and air barrier properties, but the two-layer construction makes a certain thickness unavoidable.

Supply Airflow

Aper ture Plate

Exchangeable

CO2 Sensor

Extra Low mode (LGH-RX5-E)

Lossnay systems allow you to measure CO2 density (via an independent, 3rd par ty CO2 sensor) and thereby control the amount of fresh air supplied to a building. By connecting a CO2 sensor to the Lossnay unit, the system will switch fan speeds automatically depending on the CO2 level.

In addition to the conventional fan speeds, an Extra Low mode has been added to provide a more dynamic range of air volume settings. This provides versatility in a variety of installation environments, yielding better energy conservation.

Normal Office

Small Office or Building

Industrial Areas

Providing efficient ventilation while maintaining air supply/exhaust balance...

Using Lossnay compensates for using extractor fans...

Priority on air exhaust...

Power air supply & air exhaust

Power air supply

Power air exhaust

Most widely-used pattern forming the basis for traditional ventilation design. This allows the most efficient ventilation while maintaining the air supply/exhaust balance. The optimum ventilation rate can be maintained by selecting the Power air supply/exhaust mode with both the air supply & air exhaust switched to "High" (or "Extra high") on the main unit. For example in an office, the control switches can be set to "High" to run in Power air supply/exhaust mode when a large number of people are in the office, then switched to "Low" to run in Energy-saving ventilation mode late at night or on holidays when there are few people present.

In smaller offices or buildings, there may be insufficient air supply to the main rooms or offices due to the excessive exhaust via extractor fans located in toilets or kitchen areas. Setting to Power air supply mode with the air supply switch on "High" (or "Extra high") and the air exhaust switch on "Low" on the main unit, allows efficient ventilation while making up for the insufficient air supply.

In locations such as industrial working areas, dirty air must be exhausted swiftly. Setting the Power air exhaust mode with the air supply switch on "Low" and the air exhaust switch on "High" (or "Extra high") on the main unit allows efficient extraction of fumes and odours. Maintaining the area at a negative air pressure also prevents dirty air from spreading to surrounding areas.

Page 253


Restaurants

Schools

A restaurant can never be too clean and its air never too fresh

Creating the best possible environment for our children to succeed

The atmosphere of a restaurant is crucial to securing and retaining customers. Cleanliness is the key to an attractive atmosphere and restaurants devote significant effort to ensuring their premises are as such. Sanitation and cleanliness, however, are not enough. No matter how clean a restaurant may look, if there are bothersome odours lingering in the air, all those efforts go to waste and the restaurant's clean image is tarnished.

Children deserve all the help we can give them to grow up healthy, happy and prosperous. No matter how good a school's curriculum, no matter how positive and enthusiastic the teacher, a child who does not feel well will have a hard time learning. A constant flow of fresh air is nowhere as important as it is in our schools. In classrooms where large numbers of students are gathered for long periods of time, carbonic gases have the tendency to accumulate, decreasing the levels of oxygen that are vital for alertness and concentration.

For these reasons, Lossnay’s superior ventilation capabilities ensure that every breath is a fresh one and a pleasant environment is maintained for guests at all times. Lossnay also keeps owners happy with its remarkable heat recovery technology that supplies fresh outdoor air with minimal change to indoor temperature, saving on energy costs.

This is especially true during the winter months when windows tend to remain closed. Lossnay ventilates fresh outdoor air into classrooms to replenish the supply of oxygen and expels not only carbon dioxide, but also other pollutants and odours that inevitably sully the air.

If it’s Lossnay

If it’s Lossnay

Lossnay works to remove stale air and supply fresh, clean air free of the odours associated with cooking, cigarettes and the people working and dining.

The continuous influx of fresh, outdoor air and the exhaust of stale, indoor air ensure that the indoor oxygen level is maintained at just the right balance for comfort and health.

Change in room temperature is kept to a minimum during ventilation thanks to the heat-recovery function.

Occupants have the luxury of breathing fresh air at all times, even in highly air-tight buildings. Lossnay's sound attenuation qualities prevent outside noise from penetrating into the room, helping to maintain a quiet environment for productive study.

The Lossnay operate very quietly, so those in the midst of enjoying their meals will not be bothered by any excess noise.

O2 Concentration and Deficiency

What would you most like to see improved in restaurants?

52.3%

2

Page 254

6% Convulsions, respiration stops, death

0

8% Comatosis (death in 8 min)

5

10 % Paleness of skin, vomiting, Unconsciousness

10

Dizziness, nausea, loss of muscle strength (precursors of death)

12 % Increased respiration and pulse

1996 Foodstuffs Consumption Monitor, Second Periodic Survey ( Ministry of Agriculture, Forestry and Fisheries, Japan)

16 % 15

Safety minimum

Improvement in employees attitude towards customers: 20.5%

18 %

Normal air

Reduction of time required for food to reach the table: 12.0%

21 %

21

O2 Concentration (%)

Improvement in overall cleanliness

Offices

Heat-exchange technology prevents fluctuations in temperature creating significant energy savings when either heating or cooling a room.

A large array of Lossnay sizes are available to match the layout of just about any restaurant.

Others: no response Promotion of waste prevention: 5.4% Improvement in atmosphere: 6.5%

Occupants have the luxury of breathing fresh air at all times, even in highly air-tight buildings

If it’s Lossnay

Fresh air - improving the overall quality of working life Many office buildings today are heavily insulated, air-tight structures with little or no natural ventilation. The unnatural environment created by air conditioners without added ventilation is a breeding ground for bacteria. Factor this in with the accumulation of pollutants and odours in the form of formaldehyde, pollen, dust, carbon dioxide and the necessity of ventilation becomes ever more apparent. In fact, poorly ventilated buildings can give rise to Sick Building Syndrome, a malady that is known to cause headaches, sore eyes, itching and loss of concentration. This results not only in discomfort at best and sickness at worst for the building's occupants, but also the reduced productivity of the workforce. Fresh air, effectively ventilated throughout the building is therefore essential to the overall quality of working life.

Simultaneous forced-air supply and exhaust introduces fresh, outdoor air into the building, effectively ventilating even fully airtight structures. Multiple split-type units operate independently of one another, simplifying system set up and ensuring a layout that optimally matches nearly any office design. Lossnay operation can be interlocked with air-conditioning system operation. Heat that is commonly lost due to ventilation is collected and reused thanks to the Lossnay Core, reducing an air conditioners energy load and cutting operating costs.

Page 255


The Unbeatable

Lossnay

Contents 258

Total Heat Exchangers Residential Model

260

LGH-RSDC-E DC Lossnay Model

262

LGH-RX5-E Commercial Series

The Lossnay allows the extraction of stale air and efficient recovery of heating or cooling energy to treat incoming fresh air. Whatever your environment, it’s simple to improve it with Lossnay.

Simple technology at its best Many of our systems are registered on the Energy Technology List and hence qualify for 100% first year enhanced capital allowances. For further information please go to www.eca.gov.uk

Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB. Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB. UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. UK Conditions: Winter; indoor 21˚C DB; outdoor -1˚C WB.

Page 256

Page 257


Residential Model

VL 100U

Particularly suitable for modern homes with high insulation afforded by double glazing and cavity insulation, which require ventilation to remove stale air without major heat loss. I

Effective fresh air ventilation

I

Efficient recovery of heating/cooling energy

I

Good sound attenuation

I

Reduces heating costs

Lossnay Range

Total Heat Exchangers

Dimensions

Technical Information LOSSNAY MODEL REFERENCE

RESIDENTIAL WALL- MOUNTED VL 100U

ELECTRICAL POWER SUPPLY

220-240V, 50Hz

PHASE POWER CONSUMPTION (W) Low

23

High

26

Low

65

High

105

Low

29.5

High

39

Low

77

High

70

AIRFLOW (m3/h)

NOISE (dBA)

TEMPERATURE EXCHANGE EFFICIENCY (%) WEIGHT (kg) DIMENSIONS (mm)

DUCT SIZE (mm)

6.5 Width

620

Depth

168

Height

265 2xĂ˜75

FUSE RATING (BS88) - HRC (A)

6

MAINS CABLE No. Cores

3

Page 258

Total Heat Exchangers Residential Model

Single

Page 259


DC Lossnay Model

Lossnay-5-FSC Interface

Particularly suitable for modern homes with high insulation afforded by double glazing and cavity insulation, which require ventilation to remove stale air without major heat loss. This model is also suitable for a number of non-residential applications such as schools.

I

Control up to 16 DC Lossnay units

I

Automatic fan speed control based on CO2 level (5 speeds)

I

Effective fresh air ventilation

I

Interlock with a PIR sensor or switch

I

Efficient recovery of heating/cooling energy

I

Interlock with a CO2 sensor or BEMS (0-10v DC)

Good sound attenuation

I

I

Dimensions (WxDxH) mm: 160x80x120

I

Reduces heating costs

I

Low power consumption with 5 variable fan speeds

I

New “Hyper Eco Core” facilitating improved humidity penetration

I

By-pass mode for ‘free cooling’. Including new power mode to supply a greater volume of fresh, cool air - for instance during summer nights

I

SAP Appendix Q eligible

I

Optimise the fan speed based on CO2 level using the Lossnay-5-FSC interface

Lossnay Range

LGH-RSDC-E

Dimensions

LGH-50RSDC-E Front View

>

Upper View

Technical Information

Left Side View

>

> Right Side View

>

LOSSNAY MODEL REFERENCE

LGH-50RSDC-E

220-240V, 50Hz

ELECTRICAL POWER SUPPLY

2

STARTING CURRENT (A) LOSSNAY

BYPASS

1

2

3

4

5

POWER

1

2

3

4

5

INPUT POWER (W)

172

92

42

23

14

279

172

92

42

22

14

AIRFLOW (m3/h)

445

340

240

160

100

520

445

340

240

160

100

AIRFLOW (l/s)

124

94

67

44

28

144

124

94

67

44

28

EXTERNAL STATIC PRESSURE (Pa)

75

45

25

10

5

102

75

45

25

10

5

NOISE (dBA)

31

26

21

18

18

35

31

26

21

18

18

TEMPERATURE EXCHANGE EFFICIENCY (%)

75

80

84.5

87.5

90

-

-

-

-

-

-

Heating

68.5

73.5

78

81.5

83.5

-

-

-

-

-

-

Cooling

65.5

71

76

79.5

82.5

-

-

-

-

-

-

FAN SPEED

ENTHALPY EXCHANGE EFFICIENCY WEIGHT (kg) DIMENSIONS (mm)

DUCT SIZE (mm)

45 Width

1099 + 73

Depth

898

Height

302

>

200

FUSE RATING (BS88) - HRC (A)

6

MAINS CABLE No. Cores

3

Page 260

Rear View

LGH-50RSDC-E DC Lossnay Model

VENTILATION MODE

Page 261


Dimensions

Commercial Series

LGH-15RX5-E to LGH-200RX5-E

This commercially orientated system can be utilised virtually anywhere.

Lossnay Controller PZ-60DR-E

I

Effective fresh air ventilation

I

High heat recovery

I

Free cooling function

I

Good sound attenuation

I

New “Hyper Eco Core”. At only 25µm the Lossnay core uses the thinnest paper in the world to achieve high enthalpy exchange efficiency

I

The Lossnay-5-FSC Interface can also be used with LGH-RX5-E units. However, automatic fan speed control is with 3 speeds

Technical Information

LGH-15-100RX5-E

I

Control up to 15 Lossnay units

I

New dot matrix display

I

Weekly timer (ability to pre-set air volume requirements at different intervals)

I

Night purge function

I

Dimensions (WxDxH) mm: 130x19x120

>

LGH-150-200RX5-E

Lossnay Range

LGH-RX5-E

>

LOSSNAY

High

Notes: Running Current, Input Power and Recovery Efficiency are based on the above airflow rate, power supply 240v, 50Hz. Extra High and High mode available via dip switch setting. Extra Low mode not available on sizes 150 and 200. Noise measured at 1.5m under the centre of panel. *1: EU-F7 filter available as optional parts.

Page 262

By-pass damper plate

By-pass damper plate Air exhaust fan

RA (return air)

EA (exhaust air outlet)

1010

EA (exhaust air outlet)

RA (return air) B C

A 270

LOSSNAY core

Inspection opening

Air supply fan Control box

C

Maintenance cover High efficiency filter(sold separately) attachment position

Core, air filter, HighEfficiency filter, fan, Maintenance space

Inspection opening

Air supply fan

399 798

Control box

Power supply cable opening

Maintenance cover

A

High efficiency filter(sold separately) attachment position

LOSSNAY core 44

Position where duct direction change is possible

SA (supply air) 27

Core, air filter, HighEfficiency filter, fan, Maintenance space

OA (outside air intake)

150~250

SA (supply air) Power supply cable opening

OA (outside air intake)

Ceiling suspension fixture (4-15x30 oval)

110

Ceiling suspension fixture (4-13x20 oval)

270

Air exhaust fan

D

More than 600

220-240V, 50Hz 220-240V, 50Hz 220-240V, 50Hz 4.6 7.3 11.9 0.90 1.70 2.90 3.40 2.10 3.20 4.20 2.40 3.50 4.80 200 380 680 785 475 740 980 535 830 1100 415 755 1300 1580 1000 1500 2000 115 210 361 439 278 417 556 18 60 100 65 110 135 105 170 175 165 22 32.5 35 34 35 37.5 38 37 39 40 22 33 37 35 36 39 39 38 40.5 41 87 83 81 83 80 80 80 80 80 80 80 74 72.5 73.5 72.5 72 72.5 79 73 71.5 72 71 70.5 71 59 105 118 1231 1004 1231 1144 1144 1144 399 798 798 (SA,RA)250 (OA,EA)270x700 (SA,RA)250 (OA,EA)270x700 250 EU-G3 EU-G3 EU-G3 10 16 6 3 3 3

E

220-240V, 50Hz 3.8 0.65 1.45 1.60 1.75 145 340 370 415 355 700 800 99 194 222 20 95 120 150 22 31 33 34.5 22 32 34 35.5 87.5 80.5 79 79 79.5 72.5 71 79.5 71.5 70 53 1004 1144 399 250 EU-G3 6 3

B

220-240V, 50Hz 4.4 0.60 1.20 1.50 1.80 140 265 322 380 265 520 650 74 144 181 8 50 80 120 22 31.5 33 34.5 22.5 30.5 33.5 35 86 80 77 77 78 70.5 68.5 77 68.5 66 40 954 908 386 200 EU-G3 6 3

150 ~250

220-240V, 50Hz 3.0 0.40 0.85 1.00 1.25 95 190 228 286 180 390 500 50 108 139 10 60 90 155 19 28 32 34 19 29 32.5 35 86 81 78 78 78 71 69 77 68 66.5 32 1016 888 315 200 EU-G3 6 3

1144

79

Air filters (EU-G3)

Air filters(EU-G3)

LGH RX5-E Commercial Series

High

220-240V, 50Hz 2.4 0.30 0.51 0.74 0.92 69 116 169 212 115 210 350 32 58 97 9 30 80 160 18 23 29.5 32 18 24 30.5 32.5 88 85 80 80 81.5 76.5 71.5 81 75.5 71 29 874 888 315 150 EU-G3 6 3

242 258

High

220-240V, 50Hz 0.9 0.18 0.27 0.48 0.55 42 62 114 129 105 155 250 29 43 69 9 25 60 85 19 21.5 26 27 19 22 26.5 27.5 83.5 81.5 79 79 77.5 74 69.5 76 72.5 68 20 735 780 273 150 EU-G3 6 3

242 258

High

220-240V, 50Hz 0.8 0.15 0.25 0.38 0.46 35 59 90 110 70 110 150 19 31 42 14 40 70 105 18 23.5 27 28 19 24 28 29 85.5 84 82 82 81 77.5 75 81 76.5 73 20 735 780 273 100 EU-G3 6 3

More than 600

ELECTRICAL POWER SUPPLY STARTING CURRENT (A) RUNNING CURRENT (A) Extra Low Low High Extra High INPUT POWER (W) Extra Low Low High Extra High AIRFLOW (m3/h) Extra Low Low High / Extra AIRFLOW (l/s) Extra Low Low High / Extra EXTERNAL STATIC Extra Low PRESSURE (Pa) Low High Extra High NOISE (dBA) Lossnay Extra Low Low High Extra High Bypass Extra Low Low High Extra High TEMPERATURE Extra Low EXCHANGE Low EFFICIENCY (%) High Extra High ENTHALPY Heating Extra Low EXCHANGE Low EFFICIENCY (%) High / Extra Cooling Extra Low Low High / Extra WEIGHT (kg) DIMENSIONS (mm) Width Depth Height DUCT SIZE (mm) 1 * STANDARD FILTER FUSE RATING (BS88) – HRC (A) MAINS CABLE NO. CORES

Position where duct direction change is possible

COMMERCIAL COMMERCIAL COMMERCIAL COMMERCIAL COMMERCIAL COMMERCIAL COMMERCIAL COMMERCIAL COMMERCIAL LGH-15RX5-E LGH-25RX5-E LGH-35RX5-E LGH-50RX5-E LGH-65RX5-E LGH-80RX5-E LGH-100RX5-E LGH-150RX5-E LGH-200RX5-E

700

MODEL REFERENCE

Notes: Please use the Lossnay Technical Databook for specific, individual model schematics.

MODEL REFERENCE A

DIMENSIONS B

C

LGH-15RX5-E

780

735

273

768

782

Ø100

LGH-25RX5-E

780

735

273

768

782

Ø150

LGH-35RX5-E

888

874

315

875

921

Ø150

LGH-50RX5-E

888

1016

315

875

1063

Ø200

LGH-65RX5-E

908

954

386

895

1001

Ø200

LGH-80RX5-E

1144

1004

399

1010

1036

Ø250

LGH-100RX5-E

1144

1231

399

1010

1263

Ø250

MODEL REFERENCE

A

B

C

LGH-150RX5-E

1004

690

1045

LGH-200RX5-E

1231

917

1272

CEILING SUSPENSION FIXTURE PITCH D E

NOMINAL DIAMETER E

Page 263


Lossnay Range

Accessories / Optional Extras M Series High Efficiency Filter

PZ-25RFM

- for LGH-15RX5-E / LGH-25RX5-E

PZ-35RFM

- for LGH-35RX5-E

PZ-50RFM

- for LGH-50RX5-E

PZ-65RFM

- for LGH-65RX5-E

PZ-80RFM

- for LGH-80RX5-E / LGH-150RX5-E (2 sets)

PZ-100RFM

- for LGH-100RX5-E / LGH-200RX5-E (2 sets)

Accessories / Optional Extras

The High Efficiency Filter (with 65% colorimetricity EU-F7) can be incorporated inside the Lossnay LGH-RX5-E unit easily

Page 264


Controls A Comprehensive Range of Control Options

Air Conditioning Commercial Heating Domestic Heating Photovoltaics


The Importance of Control The need for control is paramount in order to optimise the performance of any air conditioning system and minimise its running costs and the emissions generated. Mitsubishi Electric offer a wide range of control options designed to do just this. Operating an air conditioning system without the right control can prove costly. It’s therefore important to ensure that every system is correctly specified to the degree of control it requires. Mitsubishi Electric have a wide range of controls available ‘off-the-shelf’ and where needed, individual control systems can be specifically designed to suit. Good controls will benefit any application, large or small. Air conditioning products need to react to a variety of factors: different room sizes, usage and staff levels, changes in the climate, electronic equipment and lighting etc. The ability to monitor the energy consumption and operation of systems is also vital. It is often said that you cannot manage what you are not measuring. Our control systems will enable simple measuring and monitoring of energy consumption and running costs to ensure operation is maintained.

Controlled Performance In accordance with the requirements of Part L2 in the Building Regulations, our control systems provide the optimum control available, combined with the most efficient use of energy.

A Degree of Difference When an air conditioning system is not properly controlled, it will not run as efficiently as it should. For every degree that the system deviates from the required temperature, energy costs can rise by up to 5%. Specify one of the many control options from Mitsubishi Electric to ensure air conditioning works as intended, whilst giving the optimum amount of control.

The Simpler the Better With the array of comprehensive control systems available from Mitsubishi Electric, it becomes simple to design and install air conditioning systems. From a simple hand held controller to an AG150 system - you are in control.

So whatever the application, optimum control of air conditioning systems is essential and will result in a constant, comfortable environment, which in turn is both energy and cost efficient.

Page 266

Page 267


Which Controls Product for Which Application?

Which Controls Product for Which Function?

It is really important to match the right control with the right application. From a hotel to a retail application, the solution will be different and the right control must be applied. Application

Small

Medium

Application

Large

Notes

MELCOTEL

A hotel usually requires interfacing with a key card system and window contact. The Melcotel has been designed to do just this for up to 250 City Multi indoor units. The Melcotel can also work without a key card system

TM

Hotel

AG150

MELCOTEL

TM

TM

TM

Office

Retail

Leisure

Education

PAR-30MAA PAR-F27MEA

IO Interface

PAR-30MAA PAR-F27MEA Mini M2M PAR-30MAA PAR-F27MEA Mini M2M

AG150

Mini M2M

AG150 Maxi M2M

AG150 Maxi M2M

TG2000

Maxi M2M

AG150 TG2000

AG150 TG2000

In an office application there is usually someone managing the air conditioning, so the interface needs to be simple to use. The user friendly AG150 touch screen is one option, as well as the TG2000 PC graphical user interface Retail shops are usually managed by head offices or facility management companies, so it is key to have remote monitoring of the air conditioning, but also any building services which can also be connected to the M2M interfaces In small applications the M2M platform can be a solution, as well as the AG150 touch screen or the TG2000 software package for larger applications In small applications the M2M platform can be a solution, as well as the AG150 touch screen or the TG2000 software package for larger applications

Low

Cost and Features

High

Notes

Option 1

Option 2

Option 3

Option 4

Option 5

Remote On/Off or fire alarm

PAC-SA89TA

TCB1

IO Interface

AT50

AG150 and PAC-YG10HA

On/Off remote controller button lock except TCB1

Monitor run and faults

PAC-SA88HA

IO Interface

AT50

AG150 and PAC-YG10HA

-

Relays or power supply may be required

Window interlocking

PAC-SA89TA

TCB1

-

-

-

Controller will be centrally controlled when window opened

Setpoint limit

PAR-30MAA

PAR-F27MEA

AT50

AG150

AG150 and TG2000

Available in Heat, Cool and Auto modes

Weekly timer

PAR-30MAA

AT50

AG150

AG150 and TG2000

M2M

Setpoint, On/Off can be reset

Night set back

TCB1

AT50

AG150

AG150 and TG2000

M2M

TCB1 requires thermostat, timeswitch, 12v power supply

Energy monitoring

AG150 and AG150 and PAC-CN32WHMC-UK PAC-YG60MCA

TG2000, AG150 and PAC-YG60MCA

Mini M2M

Maxi M2M

Different options for each choice. Meters required

Load shedding

AG150 and PAC-YG60MCA

Mini M2M

Maxi M2M

-

-

Energy meters required

Trend logging

AG150 and TG2000

Mini M2M

Maxi M2M

-

-

CSV data available on a spreadsheet

Night mode

PAC-SA89TA

AG150

-

-

-

PAC-SA89TA requires a third party timer

Ambient tracking

AG150 and PAC-YG63MCA

Mini M2M

Maxi M2M

-

-

PT100 sensor required

Key card interlock for hotel

AG150, MELCOTEL AG150-Interlock and PAC-SA89TA and PAC-SA89TA

-

-

-

Volt free contact for key card normally open

Window sensor interlock for hotel

MELCOTEL and PAC-SA89TA

-

-

-

-

Volt free contact for key card normally closed

2 setpoints (1 for cool and 1 for heat)

IO Interface

Mini M2M

Maxi M2M

-

-

For instance, 19ยบC Heat and 23ยบC Cool. Fan only in between

Duty / Standby

PAR-30MAA

PANEL_RS_SMS -

-

-

Backup, rotate, join in and high temperature function

A/C faults via SMS

Micro M2M

-

-

-

-

SIM card not supplied

Optimised start

AG150

-

-

-

-

-

Mini BEMS

Mini M2M

Maxi M2M

-

-

-

-

TM

TM

NOTE: The PAC-SA89TA is also known as a 3 wire adaptor and the PAC-SA88HA is also known as a 5 wire adaptor DISCLAIMER: These options are for guidance only

Page 268

Page 269


A Wide Range of Control Options The need for control is paramount in order to optimise the performance of any air conditioning system and minimise its running costs. Mitsubishi Electric offer a wide range of control options designed to do just this. With the array of comprehensive control systems available from Mitsubishi Electric, it becomes simple to design and install air conditioning systems. From a simple hand held controller to an AG150 system you are in control.

Page 270

Contents 272

Remote Controllers

290

TG2000 WAN Software (Wide Area Network)

273

AT50 Controller, Centralised Controller

291

TG2000, Screenshots

274

Interfaces

292

BEMS BACnet Interface (BAC-IP/50)

275

IO Interface

293

BEMS BACnet Interface (BAC-HD150)

276

AG150 Controller, Centralised Controller

294

BEMS BACnet Mr Slim Interface (BAC-A/50)

277

AT50/AG150 Controller, Touch Screen Examples

295

BEMS LonWorks Interface (LMAP)

278

AG150 Expansion Controller (PAC-YG50ECA)

296

BEMS Modbus Interface (MOD-IP/50)

279

GB50ADA Controller, Centralised Controller

297

BEMS Modbus Mr Slim Interface (A32M)

280

AG150/GB50 Controller, Web Screenshots

298

BEMS Modbus Splits Interface (A1M)

281

PAR-21PC Desktop Remote Controller

299

BEMS KNX-EIB Interfaces (KNX-EIB-IP-15/100)

282

AG150/GB50 Third Party Equipment Interfaces

300

BEMS KNX-EIB Splits Interface (KNX-EIB-A-1)

283

AG150/GB50 Melcotel Hotel Interface, with key card system

301

BEMS Trend Interface (Trend IQ3 Excite)

302

284

AG150/GB50 Melcotel Hotel Interface, without key card system

M2M - Machine 2 Machine Interface (Maxi M2M-IP/50)

303

285

AG150/GB50 Melcotel Hotel Interface, with M2M

M2M - Machine 2 Machine Splits Interface (Mini M2M-A/16)

304

286

TG2000 Software, PC Based Software Package

M2M - Machine 2 Machine Splits Interface (Micro M2M-SMS-A/08)

287

TG2000 Software with Energy Monitoring

305

M2M - Machine 2 Machine Web Screenshots

288

Energy Monitoring

306

Run Standby Panel (PANEL_RS_SMS)

289

TG2000 Software with Third Party Equipment

307

Split-System A2M Interfaces

TM

TM

TM

Page 271


AT50 Controller

Our air conditioning systems are supported by a multitude of remote controllers. Each remote controller type, whilst being able to support the general control and monitoring functions for a group of indoor units, can also offer other unique operational features.

PAC-SE51CRA

BS-51COV-B

PS-51COV-B

PB-51COV-B

PAR-30MAA

PAR-F27MEA

PAR-FL32MA

Technical Information Remote Controllers FUNCTION

DESCRIPTION

ON/OFF

Run and Stop operation for a single group

MODE SELECTION

Switches between Cool/Dry/Auto/Fan/Heat. Operation mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems

PAC-YT51CRB PAC-SE51CRA

PAR-30MAA

Display

Operation

Display

Operation

Display

Operation

Display

Operation

Display

Sets the groups temperature control. Cool/Dry: 19-30°C Heat: 17-28°C Auto: 19-28°C

FAN SPEED SETTING

4 speed - Lo-Mi1-Mi2-Hi 2 speed - Lo-Hi

SETPOINT LIMIT

Limit the setpoint range

AIRFLOW DIRECTION INDEPENDENT VANE CONTROL

AT50

Air Flow angles:100º-80º-60º-40º and auto swing

Only available with PLA-RP-BA, PLFY-P-VBM-E and PLFY-P-VCM-E

Daily

TIMER OPERATION

ON/OFF time can be set.

PERMIT / PROHIBIT FUNCTION

Run/Stop, Temperature Setting, Mode Selection and Filter Reset functions can be prohibited via a higher level system controller

INDOOR RETURN AIR TEMPERATURE

Measures the intake temperature of the master unit within the group

ERROR INDICATION

Displays a 4 digit code and the affected unit address

TEST RUN FUNCTION

Allows each unit within the group to operate in test mode

VENTILATION INTERLOCK

Allows the group to be interlocked with a heat recovery Lossnay unit

OPTIONAL COVER

Brushed Stainless Steel Polished Stainless Steel Polished Brass

CONTACT NUMBER UNDER FAULT CONDITIONS

Displays under fault condition, the fault code of the unit with its address and the contact number to call

EASY MAINTENANCE WITH MR SLIM

Able to monitor info about the compressor (running current, running time, On/Off time). Also able to monitor sensors: h-exh, OU outlet, OU temp, IU inlet, IU h-exh and filter usage

BACKLIGHT DISPLAY

Backlight display. Displays current time

BUTTON LOCK

Able to lock all controller buttons, or all controller buttons except On/Off

Daily

Daily

Daily

PAC-SC51KUA

Technical Information Weekly

Weekly

Reset the unit setpoint after a period of time

SILENT MODE

Activate with scheduling the silent mode on the outdoor unit

NIGHT SET BACK

Maintain a min and max temperature

RUN / STANDBY WITH MR SLIM

Able to switch over two systems every week. If one fails, the other system starts. If the temperature is too high, the two systems start.

COMPATIBILITY

Compatible with:

AT50 Controller FUNCTION

DESCRIPTION

TOUCH SCREEN

5” QVGA touch screen

MAX No. OF INDOOR UNITS

Up to 50 indoor units can be connected

ON/OFF

Run and Stop operation for a single group

MODE SELECTION

Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems

TEMPERATURE SETTING

Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C

TIMER OPERATION

Annual or weekly. Night set back option available allowing the setpoint to be set to 12ºC

AIR FLOW DIRECTION

Air Flow angles:100º-80º-60º-40º and auto swing

FAN SPEED SETTING

4 speed: Lo-Mi1-Mi2-Hi, 2 speed: Lo-Hi

PERMIT/PROHIBIT FUNCTION

Individual prohibit operations for each remote controller function (Run/Stop,Temperature Setting, Mode Selection and Filter Reset) can be activated

INDOOR RETURN AIR TEMPERATURE

Displays the measured intake temperature from each group

ENERGY SAVING

Page 272

PAR-FL32MA

Operation

TEMPERATURE SETTING

DIMENSIONS - mm (WxDxH)

PAR-F27MEA

ERROR INDICATION

Displays a 4 digit code and the affected unit address. An error log is held

TEST RUN FUNCTION

Allows each unit within the group to operate in test mode

VENTILATION INTERLOCK

Allows the group to be interlocked with a heat recovery Lossnay unit

FIRE ALARM

Units will be switched off and the remote controller will be locked under fire alarm condition

NIGHT SET BACK

During unoccupied hours the system works in a reduced state. For instance, an unoccupied room in heating mode will keep the temperature of the room between 16 and 19°C. In cooling the temperature will range between 24 and 26°C

POWER SUPPLY

Power supply 240VAC 0.5A (PAC-SC51KUA required)

COMPATIBILITY

City Multi or Mr Slim via PAC-SF81MA or M Series via MAC-399IF

DIMENSIONS - mm

Mr Slim or M Series (via MAC-397IF)

City Multi, Mr Slim (via PAC-SF81MA) or M Series (via MAC-399IF)

City Multi, Mr Slim or M Series (via MAC-397IF)

City Multi, Mr Slim (via PAC-SF81MA) or M Series (via MAC-399IF)

City Multi (via PAR-FA32MA) or Mr Slim (via PAR-FA32MA)

120x41x70

120x41x70

120x19x120

130x19x120

157x18x57

(WxDxH)

180x30x120

Page 273

Remote Controllers / AT50 Controller

PAC-YT51CRB

The new AT50 centralised controller is a low cost version of the very popular AG150 touch screen controller. The AT50 offers the main AG150 functionality, with a very simple and easy to use 5 inch touch screen.

Controls Range

Remote Controllers


IO Interface The new IO interface has been developed to allow third party systems, for instance BEMS companies, to easily control and monitor our air conditioning systems using simple volt free contacts and 0 to 10VDC signals. By working very closely with our main retail clients we have added some beneficial energy saving features, whilst still offering an acceptable level of control for retail applications. To avoid wasting energy the IO interface can also be used to interlock third party heating systems to our air conditioning.

A range of newly created interfaces are now available for use when connecting to third party controllers.

PAC-SA89TA

IO Interface

TCB1

PAC-SA88HA

Controls Range

Interfaces

Technical Information IO Interface

TCB1

PAC-SA88HA

Technical Information Interfaces FUNCTION

DESCRIPTION

PAC-SA89TA Control

ON/OFF BUT CENTRALLY CONTROLLED

ON/OFF control. Remote controller ON/OFF button deactivated

ON/OFF BUT NOT CENTRALLY CONTROLLED

ON/OFF control. Remote controller ON/OFF button activated

TEMPERATURE SETTINGS

Sets the groups temperature control. Cool/Dry: 19-30°C Heat: 17-28°C Auto: 19-28°C

Monitor

PAC-SA88HA Control

Monitor

(12VDC)

(12VDC)

ERROR INDICATION

(12VDC) Interface compatible with:

DIMENSIONS - mm (WxDxH) NOTE: VFC: Volt free contact. PAC-SA89TA is also known as a 3 wire adaptor. PAC-SA88HA is also known as a 5 wire adaptor.

Monitor

(VFC)

RUN INDICATION

COMPATIBILITY

TCB1 Control

Mr Slim City Multi

Mr Slim City Multi

Mr Slim City Multi 80x45x80

DESCRIPTION

INPUTS / OUTPUTS

IO INTERFACE

UNIT

Max No. of indoor units

-

1 or 16*1

ON/OFF

Run and Stop operation for a single group

Input

Volt Free Contact

LOCK

Run/Stop, Temperature Setting, Mode Selection and Filter Reset functions can be prohibited

Input

Volt Free Contact

ENERGY SAVE

Energy Save can be activated. 2 options are available

Input

Volt Free Contact

TEMPERATURE SETTING

Sets the groups temperature control

Input

0 to 10VDC

MODE

Switches between Cool/Dry/Auto/Fan/Heat. Operation mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems

Input

0 to 10VDC

FAN SPEED

4 speed - Lo-Mi1-Mi2-Hi 2 speed - Lo-Hi

Input

0 to 10VDC

RUN STATUS

-

Output

Volt Free Contact

FAULT

-

Output

Volt Free Contact

HEAT / COOL

Activates when unit is in heating or cooling mode

Output

Volt Free Contact

THERMO

Activates when room temperature is 2ºC away from setpoint

Output

Volt Free Contact

COMPATIBILITY

Mr Slim and M Series

-

-

DIMENSIONS - mm (WxDxH)

85x32x138

-

-

Energy Saving Features MODE 1

MODE 2

The energy saving mode 1 sets the indoor unit to Auto mode whenever a momentary signal is applied to the ‘Energy Save’ input or whenever the on/off state is changed from OFF to ON. The unit will operate in AUTO for 0.5, 1 or 2hours and then revert back to fan only.

The energy saving mode 2 sets two setpoints for the indoor unit, one for heating and one for cooling. In between the indoor unit will be running in fan only mode.

The timer can be reset using the Energy Save input.

OFF

AUTO

09.00

OFF

AUTO

09.00

Page 274

11.00

11.00

FAN 13.00

FAN

15.00

AUTO

OFF 17.00

FAN

13.00 15.00 17.00 Active via push button

19.00

OFF 19.00

25 24 23 22 21 20 19 18

COOLING MODE

FAN ONLY MODE

HEATING MODE

*1 The IO Interface can control up to 16 indoor units when the fault output is not used. When the fault output is used only one indoor unit can be controlled.

Page 275

Interfaces / IO Interface

PAC-SA89TA

FUNCTION


AT50/AG150 Controller Touch Screen Examples

Touch Screen Centralised Controller with WebServer Capabilities

AT50 Home Screen 1

AG150 Home Screen 1

AT50 Home Screen 2

AG150 Home Screen 2

AT50 Home Screen 3

AG150 Home Screen 3

AT50 Indoor Unit Settings

AG150 Indoor Unit Settings

AT50 Scheduling

AG150 Scheduling

The AG150 Mitsubishi Electric centralised controller offers a large 9 inch touch screen display with easy control of up to 50 indoor units. The AG150 can calculate the energy used for each system. The refrigerant status check function can be activated regularly (in conjuction with the new YJM-A City Multi range) and an Internet connection with SSL security is also available to monitor and control the AG150 remotely and receive Email under fault conditions.

ETHERNET

M-NET

AG150 PAC-SC51KUA

Viewed using Microsoft® Internet Explorer

Technical Information

Controls Range

AG150 Controller

DESCRIPTION

TOUCH SCREEN

Wide high resolution 9” touch screen

OPERATION PLATFORM

CPU 1000 Mhz, 512 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2 or Windows Vista or Windows 7

MAX No. OF INDOOR UNITS

Up to 50 indoor units can be connected or 150 using an expansion controller (PAC-YG50ECA)

ON/OFF

Run and Stop operation for a single group

MODE SELECTION

Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems

TEMPERATURE SETTING

Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C

TIMER OPERATION

Annual or weekly. Night set back available allowing the setpoint to be set to 12ºC

AIR FLOW DIRECTION

Air Flow angles:100º-80º-60º-40º and auto swing

FAN SPEED SETTING

4 speed: Lo-Mi1-Mi2-Hi, 2 speed: Lo-Hi

PERMIT/PROHIBIT FUNCTION

Individual prohibit operations for each remote controller function (Run/Stop,Temperature Setting, Mode Selection and Filter Reset) can be activated

INDOOR RETURN AIR TEMPERATURE

Displays the measured intake temperature from each group

ERROR INDICATION

Displays a 4 digit code and the affected unit address including the description of the error. An error log is held

TEST RUN FUNCTION

Allows each unit within the group to operate in test mode

VENTILATION INTERLOCK

Allows the group to be interlocked with a heat recovery Lossnay unit

OPTIMISED START

The equipment is started only as early as required to bring the building to a setpoint at the time it will be occupied. Running in an optimal state helps reduce energy usage.

AUTOMATIC SETPOINT ADJUSTMENT

The AG150 will change the setpoint depending of the outdoor temperature. PAC-YG63MCA and a PT100 sensor are required (PT100 sensor not supplied by MEUK). This function is only available in COOL mode

AUTO LOCK

The AG150 screen can be password protected. When the screen goes to standby and when the AG150 restarts, a username and password will be required

NIGHT SET BACK

During unoccupied hours the system works in a reduced state. For instance, an unoccupied room in heating mode will keep the temperature of the room between 16 and 19°C. In cooling the temperature will range between 24 and 26°C

AutoCAD DRAWING

A floor plan of the building in auto-cad format can be uploaded. For the facilities department it makes viewing and adjusting settings easier

WEB LOGIN

Administrator able to allow specific function access to guest

WEB SETPOINT LIMIT

Reduce the setpoint band of each individual unit (e.g. 23ºC to 25ºC)

WEB AUTO CHANGEOVER

Automatically switch heat pump outdoor unit to cooling or heating mode depending on the requirements

WEB INITIAL SETTING

Commission the AG150 from the web pages

WEB REFRIGERANT STATUS CHECK

Activate refrigerant volume checking function on Modular City Multi systems

WEB-INTERLOCK

The AG150 can interlock indoor unit input and output together. For instance, this function could be used for Hotel applications, if card in, set unit to ON, AUTO 21ºC and if card out, set the unit to night set back. This function could also be set in conjunction with PIR sensor in meeting rooms

WEB-LOAD SHEDDING

Activate energy saving mode when energy consumption is too high

EXTERNAL INPUT/OUTPUT

Hardwired connections are available for :

Inputs: Outputs:

Level Signal-Batch Start/Stop, Batch Emergency Stop Start/Stop Status, Error/Normal Status

FIRE ALARM

Units will be switched off and the remote controller will be locked under fire alarm condition via a PAC-YG10HA

POWER SUPPLY

Power supply 240VAC 0.5A (PAC-SC51KUA required)

COMPATIBILITY DIMENSIONS - mm

City Multi or Mr Slim via PAC-SF81MA or M Series via MAC-399IF (WxDxH)

300x62x175

AG150 Software Options - Pin Code Activation

DEMONSTRATION

Web monitoring, Email, Annual scheduling AG150 - VRC Virtual remote controllers AG150 - Basic AG150 - Energy Energy monitoring, energy saving, load shedding AG150 - Interlock Interlocking function

Visit wwwL1.mitsubishielectric.co.jp/ wink_doc/wink_files/acr/menu/ag150

Page 276

AG150 Controller / AT50/AG150 Controller Touch Screen Examples

AG150 Controller FUNCTION

Page 277


PAC-YG50ECA AG150 Expansion Controller

Centralised Controller with WebServer Capabilities

The PAC-YG50ECA expansion controller allows the AG150 to monitor and control up to 150 indoors units.

The GB50 has been developed to access all your control functions from the comfort of your own PC, without the need for a controller keypad or LCD display and at a very competitive price.

Controls Range

GB50ADA Controller

M-NET

AG150

ETHERNET GB50ADA

ETHERNET

PAC-YG50ECA

PAC-YG50ECA

Viewed using Microsoft® Internet Explorer

Technical Information

PAC-SC51KUA

FUNCTION

DESCRIPTION

OPERATION PLATFORM

CPU 1000 Mhz, 512MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2 or Windows Vista or Windows 7

MAX No. OF INDOOR UNITS

Up to 50 indoor units can be connected

ON/OFF

Run and Stop operation for a single group

MODE SELECTION

Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems

TEMPERATURE SETTING

Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C

FAN SPEED SETTING

4 speed: Lo-Mi1-Mi2-Hi, 2 speed: Lo-Hi

AIR FLOW DIRECTION

Air Flow angles:100º-80º-60º-40º and auto swing

TIMER OPERATION

Annual or weekly. Night set back option available allowing the setpoint to be set down to 12ºC

PERMIT/PROHIBIT FUNCTION

Individual prohibit operations for each remote controller function (Run/Stop,Temperature Setting, Mode Selection and Filter Reset) can be activated

INDOOR RETURN AIR TEMPERATURE

Displays the measured intake temperature from each group

PAC-YG50ECA

HUB

Technical Information

PAC-YG50ECA NUMBER OF INDOOR UNITS

NUMBER OF AG150 REQUIRED 1

0 to 50

Allows the group to be interlocked with a heat recovery Lossnay unit

WEB LOGIN

Administrator able to allow specific function access to guest

0

WEB SETPOINT LIMIT

Reduce the setpoint band of each individual unit (e.g. 23ºC to 25ºC)

2

101 to 150

1

3

PAC-YG50ECA FUNCTION

DESCRIPTION

AG150 / PAC-YG50ECA CONNECTION

Ethernet. Ethernet hub and network cables required and not supplied by MEUK

POWER SUPPLY

240VAC 3.2A 250x97x266

Allows each unit within the group to operate in test mode

VENTILATION INTERLOCK

1

(WxDxH)

Displays a 4 digit code and the affected unit address. An error log is held showing the last 64 date stamped alarms

TEST RUN FUNCTION NUMBER OF PAC-YG50ECA REQUIRED

51 to 100

DIMENSIONS - mm

ERROR INDICATION

WEB AUTO CHANGEOVER

Automatically switch heat pump outdoor unit to cooling or heating mode depending on the requirements

WEB INITIAL SETTING

Commission the GB50 from the web pages

WEB REFRIGERANT STATUS CHECK

Activate refrigerant volume checking function on Modular City Multi systems

WEB-INTERLOCK

The GB50 can interlock indoor unit input and output together. For instance, this function could be used for Hotel applications, if card in, set unit to ON, AUTO 21ºC and if card out, set the unit to night set back. This function could also be set in conjunction with PIR sensor in meeting rooms

WEB-LOAD SHEDDING

Activate energy saving mode when energy consumption is too high

EXTERNAL INPUT/OUTPUT

Hardwired connections are available for :

FIRE ALARM

Units will be switched off and the remote controller will be locked under fire alarm condition via a PAC-YG10HA

POWER SUPPLY

Power supply 240VAC 3.2A

COMPATIBILITY DIMENSIONS - mm

Inputs: Level Signal-Batch Start/Stop, Batch Emergency Stop Outputs: Start/Stop Status, Error/Normal Status

City Multi or Mr Slim via PAC-SF81MA or M Series via MAC-399IF (WxDxH)

250x97x266

GB50 Software Options - Pin Code Activation G50 G50 G50 G50

Page 278

- EC - ES - PC - VRC

Energy Charge Energy Saving Capability Peak Cut Control Virtual Remote Controllers

Page 279

PAC-YG50ECA / GB50ADA Controller

GB50ADA Controller


Login

Monitor Air Conditioning - Overview

PAR-21PC Desktop Remote Controller More and more customers are using the AG150/GB50 controllers directly from their computers, so Mitsubishi Electric has launched a new, even simpler alternative which presents the customer with what looks like a standard remote controller interface - on their PC desktop. Called the PAR-21PC, the new application can also be minimised in the Desktop Toolbar, just like other Windows applications, so that the customer can have immediate control with just one click of the mouse.

Access to the web pages is secured using a customised username and password.

The first screen allows you to monitor all the units connected to the AG150/GB50. Each icon displays On/Off, Faults and timer On/Off.

Monitor Air Conditioning - Block view

Remote Controller Settings

M-NET

*NOTE 1

Controls Range

AG150/GB50 Controller Web Screenshots

ETHERNET PAC-SC51KUA

Each area of the building can be displayed with information about On/Off, Setpoint, Mode and Temperature.

Daily, Weekly and Annual Scheduling (AS PIN code)

Click on any icons in the Monitor View page to access the remote controller. Lossnay units can also be controlled. Buttons on the local controllers may be locked (On/Off, Mode, Setpoint, Filter Reset).

Monitor Fault Codes

PAR-21PC Desktop Remote Controller Scheduling may be set from the web pages. A night set back operation is available (Heat, 12ºC). Standard on the AG150/GB50.

Faults with the unit address can be displayed under fault conditions. Email status can also be shown.

Multiple Users (VRC PIN code)

Multiple Users (VRC PIN code)

If the AG150/GB50 is connected to an office LAN, the staff will then be able to access the web pages. With VRC each member of staff will have their own username and password.

Installation costs will be reduced as no wall remote controllers will need to be purchased and installed.

FUNCTION

DESCRIPTION

OPERATION PLATFORM

CPU 1000 Mhz, 512 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2

MAX No. OF INDOOR UNITS

Up to 16 indoor units within a group

ON/OFF

Run and Stop operation for a single group

MODE SELECTION

Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems

TEMPERATURE SETTING

Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C

FAN SPEED SETTING

4 speed: Lo-Mi1-Mi2-Hi, 2 speed: Lo-Hi

AIR FLOW DIRECTION

Air Flow angles:100º-80º-60º-40º and auto swing

CLOCK DISPLAY

Displays the time on the desktop controller

INDOOR RETURN AIR TEMPERATURE

Displays the measured intake temperature from each group

ERROR INDICATION

Displays a 4 digit code and the affected unit address.

TIMER OPERATION

Weekly. Maximum of 3 time sequences with 3 Start/Stop times per day for all groups can be allocated

COMPATABILITY

AG150 and GB50

*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50

Icons available to suit model type installed

Page 280

Page 281

AG150/GB50 Controller Web Screenshots / PAR-21PC Desktop RemaoteController

Technical Information


AG150/GB50 Melcotel Hotel Interface with Key Card System

The new third party equipment interfaces allow the user to monitor and control third party equipment from the AG150/GB50 web pages.

ETHERNET

*NOTE 1

PAC-YG66DCA

The MelcotelTM hotel interface allows a hotel (for example) to have more accurate control over its air conditioning. The MelcotelTM works in conjunction with the key card system installed in each bedroom in many hotels. When the room is occupied, the MelcotelTM will switch ON the unit and reset the air conditioning to predetermined settings (for instance AUTO, 21ºC). When the room is unoccupied, the MelcotelTM will monitor the temperature in the room. If the temperature is too low or too high, the MelcotelTM will restart the unit. The MelcotelTM also offers temperature adjustment facility based on the outside temperature and window open control, that allows the air conditioning to be switched off and controlled centrally when a window is opened. All of these functions provide a higher level of control and therefore more energy saving and a reduction in running costs.

PAC-YG63MCA

M-NET EQUIPMENT 1

EQUIPMENT 2

SENSOR 1

Controls Range

AG150/GB50 Third Party Equipment Interfaces

TM

SENSOR 2

AG150

Technical Information

ETHERNET

Third Party Interfaces

PAC-SC51KUA PAC-YG63MCA

2 x Digital

2 x Analogue

MAX No. OF OUTPUTS

-

2 x Digital

-

MAX No. OF EQUIPMENT

-

POWER SUPPLY

Power supply required

MONITOR

2

-

24VDC

24VDC

From AG150/GB50 web pages or TG2000

Run / Faults

Temperature / Humidity

CONTROL

From AG150/GB50 web pages or TG2000

On/Off

-

SIGNAL

Signal required to monitor and control equipment

Volt free contact

Temperature 4-20mA / 1-5V / 0-10V / Pt100 Humidity 4-20mA / 1-5V / 0-10V

DIMENSIONS - mm

(WxDxH)

-

General Equipment

200x45x120

200x45x120

Temperature / Humidity

USB

Melcotel

Key Window Card Control

Key Window Card Control

Key Window Card Control

TM

Technical Information MELCOTEL

TM

FUNCTION

DESCRIPTION

MAX No. OF INDOOR UNITS

Up to 250 indoor units

TIME TO SWITCH ON

<30s

ON/OFF

Run and Stop operation for a single group

MODE SELECTION

Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems

TEMPERATURE SETTING

Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C

OCCUPIED ROOM SETTING

Configurable. ON, AUTO, 21ºC (Factory setting)

UNOCCUPIED ROOM SETTING

Third party equipment can be monitored and controlled from the web pages.

Temperature and humidity can be monitored.

Trend Logging

Temperature / Humidity Limit

Temperature and humidity can be recorded and displayed. *NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50 NOTE 2: Temperature Sensors and Humidity Sensors not supplied by MEUK

Page 282

Limit (high and low) can be set to trigger alarms via email.

If the temperature is below 16ºC the MelcotelTM restarts the unit to ON, HEAT, 19ºC and stops the unit when the temperature has reached 18ºC (Factory setting)

If the temperature is above 26ºC the MelcotelTM restarts the unit to ON, COOL, 21ºC and stops the unit when the temperature has reached 24ºC (Factory setting)

SEASONS

Up to 4 seasons can be set-up to allow different occupied and unoccupied settings (Setpoint and mode)

OPTIONAL WINDOW CONTACT

If a window sensor is wired to the indoor unit, the MelcotelTM will automatically switch OFF the indoor unit when the window is opened

AUTOMATIC SETPOINT

The MelcotelTM will offset the occupied setpoint depending on the temperature outside (outdoor sensor supplied)

ADJUSTMENT NIGHT TIME OFFSET

During the night the MelcotelTM can offset the setpoint or just switch OFF the unit

INDOOR UNIT CONNECTION

The key card and the window contact is connected back locally to CN32. PAC-SA89TA required for each indoor unit

SOFTWARE

The MelcotelTM Configuration Manager allows the installer to set-up the interface using a USB cable. The MelcotelTM Live Status allows the user to monitor all the different values, for instance, Setpoint, Mode, Key Card IN or OUT, Window Contact etc

FIRE ALARM

Units will be switched off and the remote controller will be locked under fire alarm condition

POWER SUPPLY

240 VAC 2A

COMPATIBILITY

GB50 and AG150, but City Multi only

DIMENSIONS - mm (WxDxH)

300x70x350

DEMONSTRATION

Visit www.melcotel.co.uk for more details Page 283

TM

PAC-YG66DCA

-

Melcotel Hotel Interface with Key Card System

DESCRIPTION

MAX No. OF INPUTS

AG150/GB50 Third Party Equipment Interfaces /

FUNCTION


The MelcotelTM controller allows a hotel (for example) to have more accurate control over its air conditioning. When the unit has been switched ON by a user, the room is deemed as occupied and the MelcotelTM resets the air conditioning to predetermined settings (for instance AUTO, 21ºC). After a preset time, the MelcotelTM will switch OFF the unit automatically. When the room is unoccupied, the MelcotelTM will monitor the temperature in the room. If the temperature is too low or too high, the MelcotelTM will restart the unit. The MelcotelTM also offers temperature adjustment facility based on the outside temperature and window open control, that allows the air conditioning to be switched off and controlled centrally when a window is opened. All of these functions provide a higher level of control and therefore more energy saving and a reduction in running costs.

AG150/GB50 Melcotel Hotel Interface with Machine 2 Machine TM

The MelcotelTM hotel interface can be connected to the Mini M2M Machine 2 Machine interface to allow remote monitoring of the air conditioning, but also the window contact and the key card system.

Mini M2M-A/16

M-NET

MEUK M2M SERVER

GPRS

Melcotel

TM

Melcotel

TM

Controls Range

AG150/GB50 Melcotel Hotel Interface without Key Card System TM

AG150

ETHERNET PAC-SC51KUA

USB

Mini M2M-A/16 Window Control

Window Control

Window Control

Melcotel

TM

Technical Information TM

MELCOTEL

TM

FUNCTION

DESCRIPTION

MAX No. OF INDOOR UNITS

Up to 250 indoor units

FUNCTION

TIME TO SWITCH ON

<30s

MAX No. OF INDOOR UNITS: UP TO 250

ON/OFF

Run and Stop operation for a single group

ON/OFF

MODE SELECTION

Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems

TEMPERATURE SETTING

Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C

OCCUPIED ROOM SETTING

Configurable. ON, AUTO, 21ºC (Factory setting)

MODE ROOM TEMPERATURE SET TEMPERATURE SET BACK KEY CARD

UNOCCUPIED ROOM SETTING

WINDOW SENSOR EXTERNAL TEMPERATURE

If the temperature is above 26ºC the MelcotelTM restarts the unit to ON, COOL, 21ºC and stops the unit when the temperature has reached 24ºC (Factory setting)

SEASONS

Up to 4 seasons can be set-up to allow different occupied and unoccupied settings (Setpoint and mode)

OPTIONAL WINDOW CONTACT

If a window sensor is wired to the indoor unit, the MelcotelTM will automatically switch OFF the indoor unit when the window is opened

AUTOMATIC SETPOINT

The MelcotelTM will offset the occupied setpoint depending on the temperature outside (outdoor sensor supplied)

AUTO SWITCH OFF

6 Off times can be preset to regularly switch OFF the indoor unit

ADJUSTMENT NIGHT TIME OFFSET

During the night the MelcotelTM can offset the setpoint or just switch OFF the unit

INDOOR UNIT CONNECTION

The window contact is connected back locally to CN32. PAC-SA89TA required for each indoor unit

SOFTWARE

The MelcotelTM Configuration Manager allows the installer to set-up the interface using a USB cable. The MelcotelTM Live Status allows the user to monitor all the different values, for instance, Setpoint, Mode, Window Contact etc

FIRE ALARM

Units will be switched off and the remote controller will be locked under fire alarm condition

POWER SUPPLY

240 VAC 2A

COMPATIBILITY

GB50 and AG150, but City Multi only

DIMENSIONS - mm (WxDxH)

300x70x350

DEMONSTRATION

Visit www.melcotel.co.uk for more details

Page 284

TM

If the temperature is below 16ºC the MelcotelTM restarts the unit to ON, HEAT, 19ºC and stops the unit when the temperature has reached 18ºC (Factory setting)

DEMONSTRATION

Visit www.melcotel.co.uk for more details Page 285

TM

Melcotel Hotel Interface without Key Card System / Melcotel Hotel Interface with M2M

MELCOTEL

Technical Information


TG2000 Software with Energy Monitoring

PC Based Software Package

PC Based Software Package

The TG2000 centralised PC based graphical software package allows the operator to control and monitor up to a maximum of 2000 indoor units. This software has been designed to connect directly to an air conditioning system via the AG150/GB50 controller, allowing the operator the required functionality to control and monitor the complete air conditioning system from a central location.

The TG2000 centralised PC based graphical software package allows the operator to control and monitor up to a maximum of 2000 indoor units. This software has been designed to connect directly to an air conditioning system via the AG150/GB50 controller, allowing the operator all the required functionality to control and monitor the complete air conditioning system from a central location. In addition to providing a centralised control facility, the TG2000 allows complete energy consumption data to be logged with user definable billing groups and electrical tariffs for billing purposes.

M-NET

M-NET

*NOTE 1 *NOTE 1

Controls Range

TG2000 Software

ETHERNET

ETHERNET

PAC-YG60MCA

PAC-SC51KUA PAC-SC51KUA

METER 1

METER 2

METER 3

METER 4

Technical Information

Technical Information TG2000 PC Based software that works in conjunction with AG150/GB50 Controller

FUNCTION

DESCRIPTION

OPERATING PLATFORM

CPU 1000 Mhz, 512 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2 or Windows Vista or Windows 7

MAX No. OF INDOOR UNITS

2000 Indoor units, 50 indoor units per AG150/GB50

OPERATIONAL SECTIONS

The software package is split into two distinctive areas, System and Controls setting. System Setting: Password protected, System Configuration and group/block organisation, printer setting. Controls Setting: Normal Operation, monitoring and control functions as described below. The software allows individual indoor units to be allocated to logical groups, represented within user definable graphics screens, allocated during the system configuration

FUNCTION

DESCRIPTION

OPERATING PLATFORM

CPU 1000 Mhz, 512 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2 or Windows Vista or Windows 7

ON/OFF

Indicates the On/Off status of each group within the selected graphical screen or entire building

MAX No. OF INDOOR UNITS

2000 Indoor units, 50 indoor units per AG150/GB50

OPERATION MODE

Indicates the operational mode (Cool, Heat, Fan, Dry, Auto) for each group on the selected graphical screen

OPERATIONAL SECTIONS

The software package is split into two distinctive areas, System and Controls setting. System Setting: Password protected, System Configuration and group/block organisation, printer setting. Controls Setting: Normal Operation, monitoring and control functions as described below. The software allows individual indoor units to be allocated to logical groups, represented within user definable graphics screens, allocated during the system configuration

SET TEMPERATURE

Displays the set temperature for each group on the selected graphical screen. Also able to limit the set point range in both heating and cooling mode

AIR SPEED

Displays the current fan speed setting for each group on the selected graphical screen

ON/OFF

Indicates the On/Off status of each group within the selected graphical screen or entire building Indicates the operational mode (Cool, Heat, Fan, Dry, Auto) for each group on the selected graphical screen

REMOTE CONTROLLER PROHIBIT/PERMIT

Displays the current prohibit/permit status for each groups remote controller on the selected graphical screen

OPERATION MODE SET TEMPERATURE

Displays the set temperature for each group on the selected graphical screen. Also able to limit the set point range in both heating and cooling mode

ABNORMALITY (FAULT) MONITORING

AIR SPEED

Displays the current fan speed setting for each group on the selected graphical screen

Individual indoor unit fault monitoring is recorded within the fault log for both viewing and printing. Fault monitoring can also be viewed via the fault log for all units associated with a particular graphical screen or the entire building. Faults can also be tracked and printed using date of failure, date of recovery and error code

REMOTE CONTROLLER PROHIBIT/PERMIT

Displays the current prohibit/permit status for each groups remote controller on the selected graphical screen

ROOM TEMPERATURE MONITORING

Displays the return air temperature of the master indoor unit within a group

SCHEDULED ON/OFF

On/Off schedules can be set for each group, each graphical screen or the entire building

ABNORMALITY (FAULT) MONITORING

Individual indoor unit fault monitoring is recorded within the fault log for both viewing and printing. Fault monitoring can also be viewed via the fault log for all units associated with a particular graphical screen or the entire building. Faults can also be tracked and printed using date of failure, date of recovery and error code

ENERGY CHARGING

Able to create or email bills for individual indoor units, groups of indoor units or a complete system (Optional) via the PAC-YG60MCA

WEB REFRIGERANT STATUS CHECK

Activate refrigerant volume checking function on Modular City Multi systems

ENERGY CHARGING

Able to create bills for individual indoor units, groups of indoor units or a complete system (Optional) via the PAC-YG60MCA

ROOM TEMPERATURE MONITORING

Displays the return air temperature of the master indoor unit within a group

SCHEDULED ON/OFF

On/Off schedules can be set for each group, each graphical screen or the entire building

ENERGY SAVE CONTROL

ENERGY SAVE CONTROL

Individual indoor unit, group of indoor units or a complete system can be controlled. There are various energy saving options available (Optional)

Individual indoor unit, group of indoor units or a complete system can be controlled. There are various energy saving options available (Optional)

LOAD SHEDDING

Activate energy saving mode when energy consumption is too high

TREND LOGGING

Able to log: Return air temperature, setpoint, mode, On/Off, power consumption by group or by indoor unit, watt-hour meter and then email to customer

TREND LOGGING

Able to log: Return air temperature, setpoint, mode, On/Off, power consumption by group or by indoor unit, watt-hour meter and then email to customer

GRAPHICAL SCREENS

The complete system configurations can be allocated between multiple screens. Each screen can display a bitmap image representing the area of the building or floor where the units or groups are physically located

GRAPHICAL SCREENS

The complete system configurations can be allocated between multiple screens. Each screen can display a bitmap image representing the area of the building or floor where the units or groups are physically located

EMAIL

The following information may be sent regularly and automatically via email: energy monitoring data, energy saving data, trend logging data (temperatures etc) and fault code history

EMAIL

The following information may be sent regularly and automatically via email: energy monitoring data, energy saving data, trend logging data (temperatures etc) and fault code history

*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50

Page 286

*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50 NOTE 2: Energy Meters not supplied by MEUK

Page 287

TG2000 Software / TG2000 Software with Energy Monitoring

TG2000 Software with Energy Monitoring


Energy monitoring is key to comply with Part L2 regulations. Some time ago we introduced the PAC-YG60MCA MNET interfaces, which can be connected anywhere on our MNET network and will monitor up to 4 pulse meters. These interfaces make installation easier, more cost effective and are shown in option A below. This year, all of our City Multi outdoor units now have a direct connection to pulse meters. This means that the pulse meter can be connected to the outdoor unit directly, negating the need for interfaces, panels and a power supply and therefore reducing the installation cost significantly. This is shown in option B below.

Option A:

TG2000 Software with Third Party Equipment PC Based Software Package The TG2000 centralised PC based graphical software package allows the operator to control and monitor up to a maximum of 2000 indoor units. This software has been designed to connect directly to an air conditioning system via the AG150/GB50 controller, allowing the operator all the required functionality to control and monitor the complete air conditioning system from a central location. In addition to providing a centralised control facility, the TG2000 allows you to monitor and control third party equipment.

M-NET

M-NET *NOTE 1

Controls Range

Energy Monitoring

*NOTE 1

ETHERNET PAC-YG60MCA

ETHERNET

PAC-SC51KUA

PAC-SC51KUA PAC-YG66DCA METER 1

METER 2

METER 3

PAC-YG63MCA

METER 4

Option B:

EQUIPMENT 1

EQUIPMENT 2

SENSOR 1

SENSOR 2

Technical Information M-NET

*NOTE 1

DESCRIPTION

OPERATING PLATFORM

CPU 1000 Mhz, 512 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2 or Windows Vista or Windows 7

MAX No. OF INDOOR UNITS

2000 Indoor units, 50 indoor units per AG150/GB50

OPERATIONAL SECTIONS

The software package is split into two distinctive areas, System and Controls setting. System Setting: Password protected, System Configuration and group/block organisation, printer setting. Controls Setting: Normal Operation, monitoring and control functions as described below. The software allows individual indoor units to be allocated to logical groups, represented within user definable graphics screens, allocated during the system configuration

ON/OFF

Indicates the On/Off status of each group within the selected graphical screen or entire building

OPERATION MODE

Indicates the operational mode (Cool, Heat, Fan, Dry, Auto) for each group on the selected graphical screen

SET TEMPERATURE

Displays the set temperature for each group on the selected graphical screen. Also able to limit the set point range in both heating and cooling mode

AIR SPEED

Displays the current fan speed setting for each group on the selected graphical screen

REMOTE CONTROLLER PROHIBIT/PERMIT

Displays the current prohibit/permit status for each groups remote controller on the selected graphical screen

ABNORMALITY (FAULT) MONITORING

Individual indoor unit fault monitoring is recorded within the fault log for both viewing and printing. Fault monitoring can also be viewed via the fault log for all units associated with a particular graphical screen or the entire building. Faults can also be tracked and printed using date of failure, date of recovery and error code

ROOM TEMPERATURE MONITORING

Displays the return air temperature of the master indoor unit within a group

SCHEDULED ON/OFF

On/Off schedules can be set for each group, each graphical screen or the entire building

ENERGY SAVE CONTROL

Individual indoor unit, group of indoor units or a complete system can be controlled. There are various energy saving options available (Optional)

TREND LOGGING

Able to log: Return air temperature, setpoint, mode, On/Off, power consumption by group or by indoor unit, watt-hour meter and then email to customer

GRAPHICAL SCREENS

The complete system configurations can be allocated between multiple screens. Each screen can display a bitmap image representing the area of the building or floor where the units or groups are physically located

ETHERNET PAC-YG60MCA PAC-SC51KUA METER 1

Technical Information

Pulse Meter Direct Connection to City Multi Outdoor Unit FUNCTION

PRODUCT REQUIRED

DESCRIPTION

OUTDOOR kW

AG150, AG150-Basic Energy Meters

The energy consumption of the outdoor can be monitored using the AG150 Webpages

INDOOR kW

AG150, AG150-Basic AG150-Energy, TG2000 Energy Meters

The energy consumption of the indoor unit can be estimated using the TG2000 software package. The software package will also allow the end user to generate bills with multiple tariffs

Product Required PAC-SA89TA

Cable required to connect the pulse meter to the outdoor unit

PAC-CN32WHMC-UK

Jumper to activate the outdoor pulse input

THIRD PARTY EQUIPMENT MONITOR

Monitor general equipment Run and Faults via the PAC-YG66DCA interface and Temperature and Humidity via the PAC-YG63MCA

THIRD PARTY EQUIPMENT CONTROL

Control general equipment On/Off via the PAC-YG66DCA

EMAIL

The following information may be sent regularly and automatically via email: energy monitoring data, energy saving data, trend logging data (temperatures etc) and fault code history

*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50 NOTE 2: Temperature and Humidity Sensors not supplied by MEUK

Page 288

Page 289

Energy Monitoring / TG2000 Software with Third Party Equipment

TG2000 Software with Third Party Equipment FUNCTION


PC Based Software Package used to monitor and control multiple sites

TG2000

Controls Range

TG2000 WAN (Wide Area Network) Software

Screenshots

Display Whole

Display Block

The 2000 indoor units status may be shown on one screen.

Block may be set for each area. Settings may be changed by one click of the mouse for each area.

Display Floor

Remote Controller Settings

AutoCAD drawing may be imported to TG2000 to display floor screens.

Click on any icons in the floor view to access the remote controller settings. Buttons on the local controllers may be locked (On/Off, Mode, Setpoint, Filter reset).

Daily, Weekly and Annual Scheduling

Monitor Fault Codes

Scheduling may be set from the TG2000. A night set back operation is available (HEAT, 12ยบC).

Faults with the unit address can be displayed under fault conditions.

Energy Monitoring (AG150 Energy PIN code)

Energy Saving (AG150 Energy PIN code)

TG2000 in conjunction with energy meters can monitor the energy consumption for each outdoor unit, indoor unit or area. The indoor unit run hours can also be displayed.

TG2000 offers different energy saving options including load shedding.

The TG2000 WAN centralised PC based graphical software package allows the operator to control and monitor up to a maximum of 1000 sites. Utilising the companies Wide Area Network, the complete (geographically distributed) air conditioning asset base can be controlled and monitored from a centralised location.

PAC-YG66DCA

WAN

PAC-YG63MCA

SITE 1 (i.e. MANCHESTER) *NOTE 1

EQUIPMENT 1

EQUIPMENT 2

SENSOR 1

PAC-YG66DCA

SENSOR 2

PAC-YG63MCA

SITE 999 (i.e. BIRMINGHAM) *NOTE 1

EQUIPMENT 1

EQUIPMENT 2

SENSOR 1

SENSOR 2

Technical Information

DESCRIPTION

OPERATING PLATFORM

CPU 1000 Mhz, 512 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2 or Windows Vista or Windows 7

MAX No. OF SITES

1000

MAX No. OF INDOOR UNITS PER SITE

2000 Indoor units, 50 indoor units per AG150/GB50 (per site)

OPERATIONAL SECTIONS

The software package is split into two distinctive areas, System and Controls setting. System Setting: Password protected, System Configuration and group/block organisation, printer setting. Controls Setting: Normal Operation, monitoring and control functions as described below. The software allows individual indoor units to be allocated to logical groups, represented within user definable graphics screens, allocated during the system configuration

ON/OFF

Indicates the On/Off status of each group within the selected graphical screen or entire building

OPERATION MODE

Indicates the operational mode (Cool, Heat, Fan, Dry, Auto) for each group on the selected graphical screen

SET TEMPERATURE

Displays the set temperature for each group on the selected graphical screen. Also able to limit the set point range in both heating and cooling mode

AIR SPEED

Displays the current fan speed setting for each group on the selected graphical screen

REMOTE CONTROLLER PROHIBIT/PERMIT

Displays the current prohibit/permit status for each groups remote controller on the selected graphical screen

ABNORMALITY (FAULT) MONITORING

Individual indoor unit fault monitoring is recorded within the fault log for both viewing and printing. Fault monitoring can also be viewed via the fault log for all units associated with a particular graphical screen or the entire building. Faults can also be tracked and printed using date of failure, date of recovery and error code

ROOM TEMPERATURE MONITORING

Displays the return air temperature of the master indoor unit within a group

SCHEDULED ON/OFF

On/Off schedules can be set for each group, each graphical screen or the entire building

GRAPHICAL SCREENS

The complete system configurations can be allocated between multiple screens. Each screen can display a bitmap image representing the area of the building or floor where the units or groups are physically located

THIRD PARTY EQUIPMENT MONITORING

Monitor general equipment Run and Faults via the PAC-YG66DCA interface and Temperature and Humidity via the PAC-YG63MCA

THIRD PARTY EQUIPMENT CONTROL

Control general equipment On/Off via the PAC-YG66DCA

EMAIL

The following information may be sent regularly and automatically via email: energy monitoring data, energy saving data, trend logging data (temperatures etc) and fault code history

TG2000 WAN Software / TG2000 Screenshots

TG2000WAN (Wide Area Network) Software FUNCTION

Icons available to suit model type installed

*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50 NOTE 2: The TG2000 WAN cannot be utilised if the following site functions are required: energy charging, energy saving and trend logging. NOTE 3: Temperature and Humidity Sensors not supplied by MEUK

Page 290

Page 291


BEMS BACnet Interface

Controls Range

BEMS BACnet Interface ®

®

BAC-HD150

Procon BAC-IP/50 TM

®

To further enhance our complete open system network offering, we offer a BACnet interface solution. Utilising the ASHRAE BACnet standard, complete control and monitoring integration can be achieved with up to 50 air conditioning units. ®

®

To further enhance our complete open system network offering, we offer a BACnet interface solution. Utilising the ASHRAE BACnet standard, complete control and monitoring integration can be achieved with up to 50 air conditioning units. ®

BAC-HD150

M-NET

*NOTE 1

ETHERNET PAC-SC51KUA

TCP / IP

TCP / IP

Technical Information

BAC-IP/50

Technical Information

BACnet INTERFACE ®

BACnet INTERFACE

FUNCTION

BAC-HD150

COMPATIBLE WITH

MAX No. OF INDOOR UNITS

50

Andover Controls

CENTRALISED CONTROLLER REQUIRED

No

York BMS

POWER SUPPLY

240VAC 3.2A

COMPATIBILITY

City Multi Mr Slim via PAC-SF81MA M Series via MAC-399IF

BEMS CONNECTION

Ethernet

DIMENSIONS - mm (WxDxH)

250x97x266

®

FUNCTION

BAC-IP/50

COMPATIBLE WITH

MAX No. OF INDOOR UNITS

50

Andover Controls

CENTRALISED CONTROLLER REQUIRED

Yes (AG150 or GB50)

POWER SUPPLY

24VAC 0.5A

COMPATIBILITY

City Multi Mr Slim via PAC-SF81MA M Series via MAC-399IF

York BMS

Siemens

BEMS CONNECTION

Ethernet via HUB

DIMENSIONS - mm (WxDxH)

144x34x104

Priva Building Intelligence

Delta Controls

Delta Controls

®

®

NETWORK VARIABLE

POINT TYPE

NOTES

FUNCTION

NETWORK VARIABLE

POINT TYPE

NOTES

On/Off

Digital Input

Run/Stop

On/Off

Digital Input

Run/Stop

Mode Operation

Analogue Input

Cool / Dry / Heat / Auto / Fan

Mode Operation

Analogue Input

Cool / Dry / Heat / Auto / Fan

Setpoint Adjustment

Analogue Input

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Setpoint Adjustment

Analogue Input

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Fan Speed Control

Analogue Input

Lo-Mi1-Mi2-Hi

Fan Speed Control

Analogue Input

Lo-Mi1-Mi2-Hi

Permit / Prohibit

Digital Input

On/Off, Mode, Setpoint

Permit / Prohibit

Digital Input

On/Off, Mode, Setpoint

Airflow Direction

Analogue Input

Horizontal - 60,80,100º swing

Airflow Direction

Analogue Input

Horizontal - 60,80,100º swing

Filter Sign

Digital Input

Normal/Reset

Filter Sign

Digital Input

Normal/Reset

Run/Stop

On/Off

Digital Output

Run/Stop

Analogue Output

Cool / Dry / Heat / Auto / Fan

BEMS BACnet® Interfaces

Control

Control

Monitor

Monitor On/Off

Digital Output

Mode Operation

Analogue Output

Cool / Dry / Heat / Auto / Fan

Mode Operation

Setpoint Adjustment

Analogue Output

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Setpoint Adjustment

Analogue Output

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Fan Speed Control

Analogue Output

Lo-Mi1-Mi2-Hi

Fan Speed Control

Analogue Output

Lo-Mi1-Mi2-Hi

Permit / Prohibit

Digital Output

On/Off, Mode, Setpoint

Permit / Prohibit

Digital Output

On/Off, Mode, Setpoint

Airflow Direction

Analogue Output

Horizontal - 60,80,100º swing

Airflow Direction

Analogue Output

Horizontal - 60,80,100º swing

Fault Code

Analogue Output

4 Character code - Indicates all unit alarms

Fault Code

Analogue Output

4 Character code - Indicates all unit alarms

Filter Sign

Digital Output

-

Filter Sign

Digital Output

-

Room Temperature

Analogue Output

-

Room Temperature

Analogue Output

-

*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50

Page 292

Priva Building Intelligence

BACnet INTERFACE

BACnet INTERFACE FUNCTION

Siemens

*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50

Page 293


®

Procon BAC-A/50

BEMS LonWorks Interface ®

LMAP

TM

®

A new BACnet Interface has been specially developed for the Mr Slim systems. The BAC-A/50 can control up to 50 individual systems.

The Mitsubishi Electric LMAP continues to strengthen the ability of our products to interface with other third party building control systems using the globally recognised and accepted open network protocol Echelon LonWorks®. LonWorks® was introduced into the building services industry a number of years ago with the aim of establishing itself as the defacto communications standard. Many hundreds of products now exist that utilise the LonWorks® protocol from complete systems like BEMS, lighting, power monitoring and security down to simple sensors and relay switches. To ensure that our products can connect directly and easily with other LonWorks® products, the L-MAP02 was designed utilising Echelon MIPS technology and was the first to provide data in the LonWorks® SNVT (Standard Network Variable Type) format.

PAC-SK82SI

Controls Range

BEMS BACnet Mr Slim Interface

M-NET

TCP / IP

BAC-A/50

FTT-10 LMAP

Technical Information

Technical Information ®

LMAP LonWorks INTERFACE

BACnet MR SLIM INTERFACE ®

FUNCTION

BAC-A/50

COMPATIBLE WITH

FUNCTION

LMAP

COMPATIBLE WITH

MAX No. OF INDOOR UNITS

50

Andover Controls

MAX No. OF INDOOR UNITS

50

Honeywell

CENTRALISED CONTROLLER REQUIRED

No

York BMS

CENTRALISED CONTROLLER REQUIRED

No

POWER SUPPLY

240VAC 0.5A

Siemens

POWER SUPPLY

240VAC 0.5A

COMPATIBILITY

Mr Slim via PAC-SK82SI

Priva Building Intelligence

COMPATIBILITY

BEMS CONNECTION

Ethernet

City Multi Mr Slim via PAC-SF81MA M Series via MAC-399IF

DIMENSIONS - mm (WxDxH)

270x75x210

Delta Controls

BEMS CONNECTION

LonWorks FTT-10

DIMENSIONS - mm (WxDxH)

340x60x360

Johnson Controls

POINT TYPE

®

LMAP LonWorks INTERFACE NOTES

Control

NETWORK VARIABLE

POINT TYPE

NOTES

Control On/Off

Digital Input

Run/Stop

On/Off

Digital Input

Run/Stop

Mode Operation

Analogue Input

Cool / Dry / Heat / Auto / Fan

Mode Operation

Analogue Input

Cool / Dry / Heat / Auto / Fan

Setpoint Adjustment

Analogue Input

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Setpoint Adjustment

Analogue Input

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Fan Speed Control

Analogue Input

Lo-Mi1-Mi2-Hi

Fan Speed Control

Analogue Input

Lo-Mi1-Mi2-Hi

Permit / Prohibit

Digital Input

On/Off, Mode, Setpoint

Permit / Prohibit

Digital Input

On/Off, Mode, Setpoint (only available when using PAC-YT51CRA or PAR-21MAA)

Filter Sign

Digital Input

Normal/Reset

Filter Sign

Digital Input

Normal/Reset

On/Off

Digital Output

Run/Stop

On/Off

Digital Output

Run/Stop

Mode Operation

Analogue Output

Cool / Dry / Heat / Auto / Fan

Mode Operation

Analogue Output

Cool / Dry / Heat / Auto / Fan

Setpoint Adjustment

Analogue Output

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Setpoint Adjustment

Analogue Output

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Fan Speed Control

Analogue Output

Lo-Mi1-Mi2-Hi

Fan Speed Control

Analogue Output

Lo-Mi1-Mi2-Hi

Permit / Prohibit

Digital Output

On/Off, Mode, Setpoint

Permit / Prohibit

Digital Output

On/Off, Mode, Setpoint (only available when using PAC-YT51CRA or PAR-21MAA)

Fault Code

Analogue Output

4 Character code - Indicates all unit alarms

Fault Code

Analogue Output

4 Character code - Indicates all unit alarms

Filter Sign

Digital Output

-

Filter Sign

Digital Output

-

Room Temperature

Analogue Output

-

Room Temperature

Analogue Output

-

Monitor

Monitor

*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50

Page 294

FUNCTION

*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50

Page 295

BEMS BACnet® Mr Slim Interface / BEMS LonWorks® Interface

®

NETWORK VARIABLE

(LTX51/LTX21 via VCI)

Smart Controls

BACnet MR SLIM INTERFACE FUNCTION

Realtime Control Systems


BEMS Modbus Mr Slim Interface

Procon MOD-IP/50

Procon A32M

To further complement the existing control and interface product ranges being offered by Mitsubishi Electric to support their air conditioning systems, the Modbus range has been developed to accommodate the typical end-user needs as experienced within the UK market.

To further complement the existing control and interface product ranges being offered by Mitsubishi Electric to support their air conditioning systems, the Modbus range has been developed to accommodate the typical end-user needs as experienced within the UK market.

TM

TM

M-NET

PAC-SK82SI

*NOTE 1

Controls Range

BEMS Modbus Interface

ETHERNET PAC-SC51KUA

Modbus RS232 / 485

Modbus

A32M

RS232 / 485 or TCP / IP

Technical Information Technical Information

MODBUS INTERFACE FUNCTION

MOD-IP/50

COMPATIBLE WITH

MAX No. OF INDOOR UNITS

50

Trend via Synapsys SXNC200

CENTRALISED CONTROLLER REQUIRED

Yes (AG150 or GB50)

POWER SUPPLY

240VAC 0.5A

COMPATIBILITY

City Multi Mr Slim via PAC-SF81MA M Series via MAC-399IF

MODBUS MR SLIM INTERFACE FUNCTION

A32M

COMPATIBLE WITH

MAX No. OF INDOOR UNITS

32

Trend via Synapsys SXNC200

CENTRALISED CONTROLLER REQUIRED

No

POWER SUPPLY

240VAC 0.5A

Invensys

North BT

COMPATIBILITY

Mr Slim via PAC-SK82SI

Interactive Homes

Cylon Satchwell Crestron (Home automation) Invensys Interactive Homes

Cylon Satchwell Crestron (Home automation)

North BT

BEMS CONNECTION

Serial RS232, RS485 or TCP / IP

Andover

BEMS CONNECTION

Serial RS232 or 485

Andover

DIMENSIONS - mm (WxDxH)

144x34x104

Siemens

DIMENSIONS - mm (WxDxH)

270x75x210

Siemens

NOTES

MODBUS MR SLIM INTERFACE - OPERATIONAL INFORMATION

FUNCTION

NETWORK VARIABLE

POINT TYPE

Control On/Off

Digital Input

Run/Stop

Mode Operation

Analogue Input

Cool / Dry / Heat / Auto / Fan

Setpoint Adjustment

Analogue Input

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Fan Speed Control

Analogue Input

Lo-Mi1-Mi2-Hi

Permit / Prohibit

Digital Input

On/Off, Mode, Setpoint

Airflow Direction

Analogue Input

Horizontal - 60,80,100º swing

Filter Sign

Digital Input

Normal/Reset

Monitor

NETWORK VARIABLE

POINT TYPE

NOTES

Control On/Off

Digital Input

Run/Stop

Mode Operation

Analogue Input

Cool / Dry / Heat / Auto / Fan

Setpoint Adjustment

Analogue Input

Cooling 19-30ºC Heating 17-28ºC Auto 19-28ºC

Fan Speed Control

Analogue Input

Lo-Mi1-Mi2-Hi

Monitor

On/Off

Digital Output

Run/Stop

Mode Operation

Analogue Output

Cool / Dry / Heat / Auto / Fan

On/Off

Digital Output

Run/Stop

Setpoint Adjustment

Analogue Output

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Mode Operation

Analogue Output

Cool / Dry / Heat / Auto / Fan

Fan Speed Control

Analogue Output

Lo-Mi1-Mi2-Hi

Setpoint Adjustment

Analogue Output

Cooling 19-30ºC

Permit / Prohibit

Digital Output

On/Off, Mode, Setpoint

Airflow Direction

Analogue Output

Horizontal - 60,80,100º swing

Fault Code

Analogue Output

4 Character code - Indicates all unit alarms

Fan Speed Control

Analogue Output

Lo-Mi1-Mi2-Hi

Filter Sign

Digital Output

-

Fault Code

Analogue Output

4 Character code - Indicates all unit alarms

Room Temperature

Analogue Output

-

Room Temperature

Analogue Output

-

*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50

Page 296

FUNCTION

BEMS Modbus Interface / BEMS Modbus Mr Slim Interface

MODBUS INTERFACE - OPERATIONAL INFORMATION

Heating 17-28ºC Auto 19-28ºC

NOTE: Not available on SEZ / SLZ

Page 297


Procon A1M

Procon KNX-EIB-IP-15/100

To further complement the existing control and interface product ranges being offered by Mitsubishi Electric to support their air conditioning systems, the Modbus range has been developed to accommodate the typical end-user needs as experienced within the UK market.

To further complement the existing control and interface product ranges being offered by Mitsubishi Electric to support their air conditioning systems, the KNX-EIB range has been developed to accommodate the typical end-user needs as experienced within the UK market.

TM

TM

M-NET

*NOTE 1

ETHERNET

Controls Range

BEMS KNX-EIB Interfaces

BEMS Modbus Splits Interface

PAC-SC51KUA

A1M

KNX-EIB

Modbus RS485 KNX-EIB-IP-15 KNX-EIB-IP-100

Technical Information

MODBUS SPLITS INTERFACE FUNCTION

A1M

COMPATIBLE WITH

MAX No. OF INDOOR UNITS

1

CENTRALISED CONTROLLER REQUIRED

No

Trend via Synapsys SXNC200 Cylon Satchwell Crestron (Home automation) Invensys Interactive Homes North BT Andover Siemens

COMPATIBILITY

M Series Mr Slim

BEMS CONNECTION

Serial RS485

DIMENSIONS - mm (WxDxH)

72x27x50

KNX-EIB CITY MULTI INTERFACES FUNCTION

KNX-EIB-IP-15

KNX-EIB-IP-100

COMPATIBLE WITH ABB

MAX No. OF INDOOR UNITS

15

100

CENTRALISED CONTROLLER REQUIRED

Yes (AG150 or GB50)

Yes (AG150 or GB50)

POWER SUPPLY

9 to 30VDC or 24VAC 0.5A

9 to 30VDC or 24VAC 0.5A

COMPATIBILITY

City Multi Mr Slim via PAC-SF81MA M Series via MAC-399IF

City Multi Mr Slim via PAC-SF81MA M Series via MAC-399IF

BEMS CONNECTION

Ethernet via HUB

Ethernet via HUB

DIMENSIONS - mm (WxDxH)

107x58x105

107x58x105

Intelligent Buildings

Nova Controls Ltd

Siemens

MODBUS SPLITS INTERFACE - OPERATIONAL INFORMATION

KNX-EIB CITY MULTI INTERFACE UNITS - OPERATIONAL INFORMATION

FUNCTION

FUNCTION

NETWORK VARIABLE

POINT TYPE

NOTES

NETWORK VARIABLE

POINT TYPE

BEMS Modbus Splits Interface / BEMS KNX-EIB Interfaces

Technical Information

NOTES

Control

Control On/Off

Digital Input

Run/Stop

On/Off

Digital Input

Run/Stop

Mode Operation

Analogue Input

Cool / Dry / Heat / Auto / Fan

Mode Operation

Analogue Input

Cool / Dry / Heat / Auto / Fan

Setpoint Adjustment

Analogue Input

Cooling 19-30ºC

Setpoint Adjustment

Analogue Input

Cooling 19-30ºC Heating 17-28ºC

Heating 17-28ºC

Auto 19-28ºC

Auto 19-28ºC Fan Speed Control

Analogue Input

Lo-Mi1-Mi2-Hi

Fan Speed Control

Analogue Input

Lo-Mi1-Mi2-Hi

Monitor

Monitor On/Off

Digital Output

Run/Stop

On/Off

Digital Output

Run/Stop

Mode Operation

Analogue Output

Cool / Dry / Heat / Auto / Fan

Mode Operation

Analogue Output

Cool / Dry / Heat / Auto / Fan

Setpoint Adjustment

Analogue Output

Cooling 19-30ºC

Setpoint Adjustment

Analogue Output

Cooling 19-30ºC Heating 17-28ºC

Heating 17-28ºC

Auto 19-28ºC

Auto 19-28ºC Fan Speed Control

Analogue Output

Lo-Mi1-Mi2-Hi

Fan Speed Control

Analogue Output

Lo-Mi1-Mi2-Hi

Fault Code

Analogue Output

4 Character code - Indicates all unit alarms

Fault Code

Analogue Output

4 Character code - Indicates all unit alarms

Room Temperature

Analogue Output

-

Room Temperature

Analogue Output

-

*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50

Page 298

Page 299


BEMS Trend Interface

Procon KNX-EIB-A-1

Trend IQ3 Excite

To further complement the existing control and interface product ranges being offered by Mitsubishi Electric to support their air conditioning systems, the KNX-EIB range has been developed to accommodate the typical end-user needs as experienced within the UK market.

Mitsubishi Electric and Synapsys Solutions have been working together for the last six years to offer very competitive solutions for Trend users. The IQ3 Excite Interface has been modified by Synapsys Solutions to work directly in conjunction with the AG150 and GB50 centralised controllers. This allows Trend users to easily integrate Trend systems with Mitsubishi Electric air conditioning.

TM

Controls Range

BEMS KNX-EIB Splits Interface

M-NET

*NOTE 1

ETHERNET

KNX-EIB-A-1

PAC-SC51KUA

KNX-EIB

Trend IQ3 Excite (must be supplied by Synapsys)

Technical Information TREND INTERFACE

Technical Information KNX-EIB SPLITS INTERFACE FUNCTION

KNX-EIB-A-1

COMPATIBLE WITH

MAX No. OF INDOOR UNITS

1

ABB

CENTRALISED CONTROLLER REQUIRED

No

COMPATIBILITY

FUNCTION

IQ3 EXCITE

COMPATIBLE WITH

MAX No. OF INDOOR UNITS

50

Trend only

CENTRALISED CONTROLLER REQUIRED

Yes (AG150 or GB50)

POWER SUPPLY

240VAC

COMPATIBILITY

City Multi Mr Slim via PAC-SF81MA M Series via MAC-399IF

BEMS CONNECTION

Ethernet via HUB

DIMENSIONS - mm (WxDxH)

263x42x130

Intelligent Buildings

M Series Mr Slim

Nova Controls Ltd

BEMS CONNECTION

KNX (TP-1) EIB

DIMENSIONS - mm (WxDxH)

60x25x48

Siemens

IMPORTANT NOTE: The IQ3 Excite Interface can only be supported by Synapsys Solutions (Tel: 01273 831831)

KNX-EIB SPLITS INTERFACE - OPERATIONAL INFORMATION FUNCTION

NETWORK VARIABLE

POINT TYPE

NOTES

NETWORK VARIABLE

POINT TYPE

NOTES

Control

Control

On/Off

Switch

Run/Stop

Mode Operation

Knob

Cool / Dry / Heat / Auto / Fan

On/Off

Digital Input

Run/Stop

Setpoint Adjustment

Knob

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Mode Operation

Analogue Input

Cool / Dry / Heat / Auto / Fan

Fan Speed Control

Knob

Lo-Mi1-Mi2-Hi

Setpoint Adjustment

Analogue Input

Cooling 19-30ºC

Permit / Prohibit

Digital Input

On/Off, Mode, Setpoint

Heating 17-28ºC

Airflow Direction

Knob

Horizontal - 60,80,100º swing

Auto 19-28ºC

Filter Sign

Digital Input

Normal/Reset

Fan Speed Control

Analogue Input

Lo-Mi1-Mi2-Hi

On/Off

Switch

Run/Stop

On/Off

Digital Output

Run/Stop

Mode Operation

Knob

Cool / Dry / Heat / Auto / Fan

Mode Operation

Analogue Output

Cool / Dry / Heat / Auto / Fan

Setpoint Adjustment

Knob

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Setpoint Adjustment

Analogue Output

Cooling 19-30ºC

Fan Speed Control

Knob

Lo-Mi1-Mi2-Hi

Heating 17-28ºC

Permit / Prohibit

Digital Output

On/Off, Mode, Setpoint

Auto 19-28ºC

Airflow Direction

Knob

Horizontal - 60,80,100º swing

Monitor

BEMS KNX-EIB Splits Interface / BEMS Trend Interface

TREND INTERFACES FUNCTION

Monitor

Fan Speed Control

Analogue Output

Lo-Mi1-Mi2-Hi

Fault Code

Sensor

4 Character code - Indicates all unit alarms

Fault Code

Analogue Output

4 Character code - Indicates all unit alarms

Filter Sign

Digital Output

-

Room Temperature

Analogue Output

-

Room Temperature

Sensor

-

*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50

Page 300

Page 301


Procon Maxi M2M-IP/50 TM

To offer remote management of its air conditioning units to companies with large numbers of dispersed offices, Mitsubishi Electric has adopted the M2M platform. The machine-to-machine (M2M) technology platform allows customers to integrate multiple sites into one network. The air conditioning units as well as third party equipment will be wirelessly connected to the M2M server and use the GPRS network to communicate. GB50ADA

Maxi M2M-IP/50

MEUK M2M SERVER

METER 1

METER 2

METER 3

METER 4

EQUIPMENT 1

EQUIPMENT 2

SENSOR 1

SENSOR 2

M2M - Machine 2 Machine Splits Interface

Controls Range

M2M - Machine 2 Machine Interface

Procon Mini M2M-A/16 TM

To offer remote management of its air conditioning units to companies with large numbers of dispersed offices, Mitsubishi Electric has adopted the M2M platform. The machine-to-machine (M2M) technology platform allows customers to integrate multiple sites into one network. The air conditioning units as well as third party equipment will be wirelessly connected to the M2M server and use the GPRS network to communicate.

Mini M2M-A/16

A1M

A1M

GPRS

Maxi M2M-IP/50

MEUK

GB50ADA

METER 1

M2M SERVER

METER 2

METER 3

METER 4

Mini M2M-A/16 METER 1

METER 2

METER 3

METER 4

EQUIPMENT 1

EQUIPMENT 2

SENSOR 1

EQUIPMENT 1

EQUIPMENT 2

SENSOR 1

SENSOR 2

GPRS

A1M

A1M

SENSOR 2

Technical Information METER 1

METER 2

METER 3

M2M INTERFACE DESCRIPTION

MAX No. OF INPUTS

22 (4 to 20mA, 0 to 10VDC, 10kΩ resistor, digital)

M2M SPLITS INTERFACE

4 (volt free contact) 12 (pulse with modulation)

FUNCTION

DESCRIPTION

MAX No. OF OUTPUTS

MAX No. OF INPUTS

8 (4 to 20mA, 0 to 10VDC, 10kΩ resistor, digital)

MAX No. OF INDOOR UNITS

50

MAX No. OF OUTPUTS

4 (pulse with modulation)

SIM CARD

Vodafone Sim Card supplied with one year contract

MAX No. OF INDOOR UNITS

16

M2M SERVER HOSTING

First year free of charge

SIM CARD

Vodafone Sim Card supplied with one year contract

POWER SUPPLY

240VAC 2A

M2M SERVER HOSTING

First year free of charge

COMPATIBILITY

City Multi, Mr Slim and M Series

POWER SUPPLY

240VAC 2A

300x70x350

COMPATIBILITY

Mr Slim and M Series via Procon A1M

DIMENSIONS - mm

M2M INTERFACE - OPERATIONAL INFORMATION FUNCTION

UP TO 25 GROUPS

UP TO 50 GROUPS

On/Off

Run/Stop

Mode Operation

Cool / Dry / Heat / Auto / Fan

Setpoint Adjustment

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Fan Speed Control

Lo-Mi1-Mi2-Hi

Permit / Prohibit

On/Off, Mode, Setpoint

Airflow Direction

Horizontal - 60,80,100º swing

Filter Sign

Normal/Reset

NETWORK VARIABLE

NOTES

Control

SENSOR 1

SENSOR 2

255x60x180

(WxDxH)

M2M SPLITS INTERFACE - OPERATIONAL INFORMATION FUNCTION

Monitor

NETWORK VARIABLE

NOTES

On/Off

Run/Stop

Control Mode Operation

Cool / Dry / Heat / Auto / Fan

Setpoint Adjustment

Cooling 19-30˚C Heating 17-28˚C Auto 19-28˚C

Fan Speed Control

Lo-Mi1-Mi2-Hi

Time Zone

Weekly scheduling available

Run/Stop

Monitor

On/Off

Run/Stop

Mode Operation

Cool / Dry / Heat / Auto / Fan

On/Off

Setpoint Adjustment

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Mode Operation

Cool / Dry / Heat / Auto / Fan

Fan Speed Control

Lo-Mi1-Mi2-Hi

Setpoint Adjustment

Cooling 19-30˚C

Permit / Prohibit

On/Off, Mode, Setpoint

Airflow Direction

Horizontal - 60,80,100º swing

Fault Code

Filter Sign

Room Temperature

4 Character code - Indicates all unit alarms -

-

Heating 17-28˚C Auto 19-28˚C Fan Speed Control

Lo-Mi1-Mi2-Hi

Fault Code

4 Character code – Indicates all unit alarms

Room Temperature

-

Time Zone

Weekly scheduling available

DEMONSTRATION

DEMONSTRATION

Visit m2m.mitsubishielectric.co.uk/demo to use the live demonstration space (login: demo / password: demo)

Visit m2m.mitsubishielectric.co.uk/demo to use the live demonstration space (login: demo / password: demo)

Page 302

EQUIPMENT 2

M2M Interface / M2M Splits Interface

(WxDxH)

EQUIPMENT 1

Technical Information

FUNCTION

DIMENSIONS - mm

METER 4

Page 303


M2M-Machine 2 Machine

Web Screenshots

MEUK Website

Login

M2M is accessible using MEUK website.

A username and password is required to monitor and control sites.

Monitor Active Alarms and Sites

Status

All sites are listed with active alarm sites.

A site can be selected to monitor each system.

Set Parameters

Reports

Indoor unit and third party equipment can be controlled from the Website.

Reports can be generated for analysis.

Dashboard

Administration

AG150/GB50 web pages are available for the air conditioning units

Using the administration level, the phone numbers and email of each duty engineer may be set and activated.

Procon Micro M2M-SMS-A/08 TM

The Micro M2M can monitor and control up to 8 splits systems. The Micro M2M cannot be connected to the M2M server but can be monitored and controlled using text messages (SMS).

Micro M2M-SMS-A/08

A1M

A1M

SMS Micro M2M-SMS-A/08

A1M

Controls Range

M2M - Machine 2 Machine Splits Interface

A1M

Technical Information M2M SPLITS INTERFACE FUNCTION

DESCRIPTION

MAX No. OF INDOOR UNITS

8

POWER SUPPLY

10 to 28VDC 2.5A

COMPATIBILITY

Mr Slim and M Series via Procon A1M

DIMENSIONS - mm

(WxDxH)

70x51x105

M2M SPLITS INTERFACE - OPERATIONAL INFORMATION FUNCTION

NETWORK VARIABLE

NOTES

On/Off

Run/Stop

Control Mode Operation

Cool / Dry / Heat / Auto / Fan

Setpoint Adjustment

Cooling 19-30˚C Heating 17-28˚C Auto 19-28˚C

Fan Speed Control

Lo-Mi1-Mi2-Hi

On/Off

Run/Stop

Monitor Mode Operation

Cool / Dry / Heat / Auto / Fan

Setpoint Adjustment

Cooling 19-30˚C Heating 17-28˚C Lo-Mi1-Mi2-Hi

Fault Code

4 Character code – Indicates all unit alarms

TEXT MESSAGE EXAMPLES REGISTER (FROM MOBILE PHONE)

To register the Micro M2M to your mobile phone, just text the PIN and “ADD”. Up to 8 numbers can be registered. For example: “1234 ADD” 1234 being the last 4 digits of the serial number

MONITOR

To monitor the units, just text “STATUS” to the unit and the Micro M2M will reply with, for example: STATUS UNIT1: OK A1M COMMS: OK DRIVE:OFF ROOM TEMP:22 TEMP SETPOINT:20 MODE:AUTO FAN:HIGH

CONTROL

To switch the unit to heat mode, just text “SET” “unit name” and “HEAT” for example: “SET UNIT1 HEAT”

FAULTS

If the unit goes into fault, the Micro M2M will send a detailed text message, for example: STATUS UNIT1: FAULT A1M COMMS: FAULT CALL 0870 3000300 FOR ASSISTANCE

Technical Information Page 304

Page 305

M2M Splits Interface / M2M Web Screenshots

Auto 19-28˚C Fan Speed Control


Split-System A2M Interfaces

Procon PANEL_RS_SMS TM

The panel PANEL_RS_SMS replaces the previous run standby panels. The new panel is smaller and uses Micro M2M technology. The panel can control up to 8 indoor units and will send a text message under fault condition. The PANEL_RS_SMS does not need the SIM card to run.

Procon PANEL_RS_SMS TM

A1M

The City Multi systems use advanced communication protocol called M-NET. The Split-Systems can be interfaced to M-NET, allowing compatibility with the main centralised controller (AG150, GB50, TG2000). An A2M adapter would be required per outdoor unit for Mr Slim and per indoor unit for Mr Slim S Series or M Series indoor units.

A1M

SMS PAC-SF81MA

Controls Range

Run Standby Panel

Technical Information PROCON PANEL_RS_SMS TM

FUNCTION

DESCRIPTION

MAX No. OF INDOOR UNITS

8

FEATURES

Buzzer / Fault LED / Auto/Manual override switch / Relay for fault output

POWER SUPPLY

240VAC 2A

COMPATIBILITY

Mr Slim and M Series via Procon A1M (WxDxH)

253x90x180

TEXT MESSAGE EXAMPLES REGISTER (FROM MOBILE PHONE)

To register the Micro M2M to your mobile phone, just text the PIN and “ADD”. Up to 8 numbers can be registered. For example: “1234 ADD” 1234 being the last 4 digits of the serial number

SET UP USING A TEXT

Enter the number of units running, the number of days to switch over and the high temperature alarm, for example: “BACKUP ON, 3, 7, 27” (“ON” to activate, “3” for 3 units running, “7” to switch over every 7 days and “27” for the high temperature alarm [all the units will be switch ON])

Example: “BACKUP ON, 2, 1, 27” = 2 units running, change daily, high temperature 27ºC Unit 1

Unit 2

Unit 3

Unit 4

Day 1

2 units running, unit 3 and 4 are in standby

Day 2

2nd day, the switching over is enabled. Unit 1 and 4 are now in standby and Unit 2 and 3 are running

Day 3

3rd day, the switching over is enabled. Unit 1 and 2 are now in standby and Unit 3 and 4 are running

Day 3

On the 3rd day, the unit 4 fails

Day 3

The next unit in standby starts automatically. Unit 1 and 3 are running, 2 is in standby and 4 in fault

Day 4

The 4th day, a high temperature is detected for instance 28ºC

Day 4

All units will then start

Technical Information SPLIT-SYSTEM A2M INTERFACES FUNCTION

PAC-SF81MA

MAC-399IF

COMPATIBILITY

Mr Slim Outdoor Unit

Mr Slim S Series / M Series Indoor Unit

CONNECTION TO

Outdoor Unit

Indoor Unit

MNET SETTINGS

Rotary Switches

Dip Switches

130x15x90

160x55x70

DIMENSIONS - mm

(WxDxH)

Run Standby Panel / Split-System A2M Interfaces

DIMENSIONS - mm

NOTE: The PANEL_RS_SMS is pre-configured as a PANEL_RS1 and can be re-configured as PANEL_RS2 or PANEL_RS3 using a jumper.

Page 306

Page 307


Swing Vane Mode Auto Vane Shutter - when unit is switched off the vane automatically closes Wide Swing - distributes air laterally by up to 150º Long Airflow Mode - particularly suitable for use in long, narrow spaces Infra-red remote controller Optimised rotary or scroll compressor Econo Cool - allows set temperature to be raised by 2ºC without any loss of comfort and a 20% gain in energy efficiency Inverter control - adjusts performance to economically match the demand for heating or cooling Auto-Restart Quiet operation

the name Mitsubishi is synonymous with excellence Known the world over, Mitsubishi is a trusted global leader associated with a variety of products and services. Founded in 1921, Mitsubishi Electric quickly rose to the forefront of the air conditioning industry - a position we still enjoy today.

Mitsubishi Electric Partner Programme Open to all contractors - large or small - the Mitsubishi Electric Partner Programme offers contractors a totally new and unique set of benefits. There are two categories within the programme - Accredited Installer and Business Solutions Partner. These levels are a straight-forward reflection of the Partner’s stage of growth. All customers signing up to the programme standards are committing to continued training and professional development.

For more information please contact your local sales office

72 different airflow patterns - 2, 3 or 4 way discharge High ceiling compatibility through wide flow air outlets Auto-Changeover Hot Start - draught prevention Factory charged refrigerant up to 30m Standard filter

Unsurpassed air conditioning from Mitsubishi Electric Air conditioning is an ideal way of controlling the internal environment of any building, large or small. It does not only provide cooling when required, but also heating and often hot water can be supplied from the same system. Providing heating and hot water as part of an integrated air conditioning system is far more efficient than traditional heating methods such as gas and as a result reduced running costs and emissions can be realised. More and more people are experiencing the benefits of comfortable working, living and leisure environments made possible with air conditioning. As market leaders, we pride ourselves in providing high performance, competitive systems with low running costs and emissions.

Optional high efficiency filter Catechin filter - improves air quality and prevents the spread of bacteria and viruses within the room

Environmental Awareness

Air Cleaning filter - catches dust particles and contaminates, helping to keep the air fresh

Mitsubishi Electric boasts an explicit commitment to sustainable business practices such as energy and resource efficiency, minimising ecological impacts and reducing greenhouse gas emissions. All of our factories and UK operations are ISO14001 registered, the international standard that ensures that we are fully aware of the environmental impact of all our processes and ensures we have procedures in place to reduce them. However, we have gone far further than any accepted minimum standards. Our ‘Environmental Vision 2021’ provides a vision for a lower emission future that influences all our policy decisions. Our Green Gateway Initiative takes this vision even further as it looks to install behavioural change in our own operations and our wider sphere of influence with contractors, consultants and end users. It looks to highlight the advantages and opportunities provided, by ensuring all of our activities are undertaken with consideration to the environment. We are also proud to be a partner within Sustainable Energy Europe, whose stated aim is to raise awareness of energy use in Europe.

Anti-Allergy Enzyme filter - artificial enzyme catalyst on the filament catches allergens Nano Platinum filter - incorporates nanometre sized platinum-ceramic particles that generate stable antibacterial and deodourising effects Plasma Duo filter system Quick clean design Drain lift pump as standard Optional drain lift pump Low unit height - minimal intrusion into occupied space High external static pressure Optional high static fan motor Fresh air knockout Branch duct knockout Double thermostat function - control the temp via a sensor in the controller or the unit (wired remote controllers only) Ceiling soiling prevention Replace Technology available Refrigerant volume check function I-See Sensor Duty Standby Operation I-Save - Recalls the preferred (preset) temperature via a single button

Mitsubishi Electric Training Options Mitsubishi Electric has four state-of-the-art training suites based at different locations around the country for your convenience. Providing training for all levels of expertise, our courses are taught by experienced engineers, with a wealth of knowledge and are all CPD accredited.

For bookings please telephone 0161 866 6089

Many of our systems have an energy label of A. These systems meet the criteria of the Energy Technology List and hence could qualify for 100% first year enhanced capital allowances (whole system cost and ‘reasonable’ cost of installation). For further information please go to www.eca.gov.uk

The Forest Stewardship Council (FSC) is an international network promoting responsible management of the world's forest. The paper this catalogue is printed on supports the development of responsible forest management worldwide. The wood comes from FSC certified, well managed forests, company controlled sources and/or recycled material.

Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB. Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB. UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. UK Conditions: Winter; indoor 21˚C DB; outdoor -1˚C WB.

www.green-gateway.co.uk www.sustenergy.org www.mitsubishielectric.com/eco

Note: The fuse rating is only a typical value, it is the responsibility of a qualified electrician/electrical engineer to select the correct cable size and fuse rating based on current regulation and site specific conditions.


Corporate Sales

Birmingham

Bristol

Tel: 0870 3000 070 Fax: 0870 3000 080

Tel: 0121 741 2800 Fax: 0121 741 2801

Tel: 01454 202050 Fax: 01454 202900

Leeds

Manchester

Scotland

Tel: 0870 3300 347 Fax: 0870 3300 348

Tel: 0161 866 6060 Fax: 0161 866 6081

Tel: 01506 444960 Fax: 01506 444961

London North Region

London Central Region

London South Region

Tel: 01707 282480 Fax: 01707 282481

Tel: 0207 928 6810 Fax: 0207 928 6569

Tel: 01689 881030 Fax: 01689 881031

Ireland Tel: +353 (0)1 419 8800 Fax: +353 (0)1 419 8890 email: sales@meir.mee.com

2011 Air Conditioning Product Catalogue

Sales Offices:

The Renewable Solutions Provider

Making a World of Difference 2011 Air Conditioning Product Catalogue

After Sales Service: 0161 866 6089 email: air.conditioning@meuk.mee.com web: www.mitsubishielectric.co.uk/aircon UNITED KINGDOM Mitsubishi Electric Europe Living Environmental Systems Division Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, England General Enquiries Telephone: 01707 282880 Fax: 01707 278881 IRELAND Mitsubishi Electric Europe Westgate Business Park, Ballymount, Dublin 24, Ireland Telephone: Dublin (01) 419 8800 Fax: Dublin (01) 419 8890 International code: (003531) Country of origin: United Kingdom – Japan – Thailand – Malaysia. ©Mitsubishi Electric Europe 2011. Mitsubishi and Mitsubishi Electric are trademarks of Mitsubishi Electric Europe B.V. The company reserves the right to make any variation in technical specification to the equipment described, or to withdraw or replace products without prior notification or public announcement. Mitsubishi Electric is constantly developing and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. All goods are supplied subject to the Company’s General Conditions of Sale, a copy of which is available on request. Third-party product and brand names may be trademarks or registered trademarks of their respective owners.

Printed in November 2010

Features Key

SAP No. 237005

Air Conditioning Designed by Square Bear Limited 01604 899099. Square Bear Limited are committed to using FSC certified paper and printers, wherever possible. The sealant process used on this catalogue is environmentally friendly, recyclable and biodegradable.

Domestic Heating

Commercial Heating Photovoltaics


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.