Corporate Sales
Birmingham
Bristol
Tel: 0870 3000 070 Fax: 0870 3000 080
Tel: 0121 741 2800 Fax: 0121 741 2801
Tel: 01454 202050 Fax: 01454 202900
Leeds
Manchester
Scotland
Tel: 0870 3300 347 Fax: 0870 3300 348
Tel: 0161 866 6060 Fax: 0161 866 6081
Tel: 01506 444960 Fax: 01506 444961
London North Region
London Central Region
London South Region
Tel: 01707 282480 Fax: 01707 282481
Tel: 0207 928 6810 Fax: 0207 928 6569
Tel: 01689 881030 Fax: 01689 881031
Ireland Tel: +353 (0)1 419 8800 Fax: +353 (0)1 419 8890 email: sales@meir.mee.com
2011 Air Conditioning Product Catalogue
Sales Offices:
The Renewable Solutions Provider
Making a World of Difference 2011 Air Conditioning Product Catalogue
After Sales Service: 0161 866 6089 email: air.conditioning@meuk.mee.com web: www.mitsubishielectric.co.uk/aircon UNITED KINGDOM Mitsubishi Electric Europe Living Environmental Systems Division Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, England General Enquiries Telephone: 01707 282880 Fax: 01707 278881 IRELAND Mitsubishi Electric Europe Westgate Business Park, Ballymount, Dublin 24, Ireland Telephone: Dublin (01) 419 8800 Fax: Dublin (01) 419 8890 International code: (003531) Country of origin: United Kingdom – Japan – Thailand – Malaysia. ©Mitsubishi Electric Europe 2011. Mitsubishi and Mitsubishi Electric are trademarks of Mitsubishi Electric Europe B.V. The company reserves the right to make any variation in technical specification to the equipment described, or to withdraw or replace products without prior notification or public announcement. Mitsubishi Electric is constantly developing and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. All goods are supplied subject to the Company’s General Conditions of Sale, a copy of which is available on request. Third-party product and brand names may be trademarks or registered trademarks of their respective owners.
Printed in November 2010
Features Key
SAP No. 237005
Air Conditioning Designed by Square Bear Limited 01604 899099. Square Bear Limited are committed to using FSC certified paper and printers, wherever possible. The sealant process used on this catalogue is environmentally friendly, recyclable and biodegradable.
Domestic Heating
Commercial Heating Photovoltaics
Swing Vane Mode Auto Vane Shutter - when unit is switched off the vane automatically closes Wide Swing - distributes air laterally by up to 150º Long Airflow Mode - particularly suitable for use in long, narrow spaces Infra-red remote controller Optimised rotary or scroll compressor Econo Cool - allows set temperature to be raised by 2ºC without any loss of comfort and a 20% gain in energy efficiency Inverter control - adjusts performance to economically match the demand for heating or cooling Auto-Restart Quiet operation
the name Mitsubishi is synonymous with excellence Known the world over, Mitsubishi is a trusted global leader associated with a variety of products and services. Founded in 1921, Mitsubishi Electric quickly rose to the forefront of the air conditioning industry - a position we still enjoy today.
Mitsubishi Electric Partner Programme Open to all contractors - large or small - the Mitsubishi Electric Partner Programme offers contractors a totally new and unique set of benefits. There are two categories within the programme - Accredited Installer and Business Solutions Partner. These levels are a straight-forward reflection of the Partner’s stage of growth. All customers signing up to the programme standards are committing to continued training and professional development.
For more information please contact your local sales office
72 different airflow patterns - 2, 3 or 4 way discharge High ceiling compatibility through wide flow air outlets Auto-Changeover Hot Start - draught prevention Factory charged refrigerant up to 30m Standard filter
Unsurpassed air conditioning from Mitsubishi Electric Air conditioning is an ideal way of controlling the internal environment of any building, large or small. It does not only provide cooling when required, but also heating and often hot water can be supplied from the same system. Providing heating and hot water as part of an integrated air conditioning system is far more efficient than traditional heating methods such as gas and as a result reduced running costs and emissions can be realised. More and more people are experiencing the benefits of comfortable working, living and leisure environments made possible with air conditioning. As market leaders, we pride ourselves in providing high performance, competitive systems with low running costs and emissions.
Optional high efficiency filter Catechin filter - improves air quality and prevents the spread of bacteria and viruses within the room
Environmental Awareness
Air Cleaning filter - catches dust particles and contaminates, helping to keep the air fresh
Mitsubishi Electric boasts an explicit commitment to sustainable business practices such as energy and resource efficiency, minimising ecological impacts and reducing greenhouse gas emissions. All of our factories and UK operations are ISO14001 registered, the international standard that ensures that we are fully aware of the environmental impact of all our processes and ensures we have procedures in place to reduce them. However, we have gone far further than any accepted minimum standards. Our ‘Environmental Vision 2021’ provides a vision for a lower emission future that influences all our policy decisions. Our Green Gateway Initiative takes this vision even further as it looks to install behavioural change in our own operations and our wider sphere of influence with contractors, consultants and end users. It looks to highlight the advantages and opportunities provided, by ensuring all of our activities are undertaken with consideration to the environment. We are also proud to be a partner within Sustainable Energy Europe, whose stated aim is to raise awareness of energy use in Europe.
Anti-Allergy Enzyme filter - artificial enzyme catalyst on the filament catches allergens Nano Platinum filter - incorporates nanometre sized platinum-ceramic particles that generate stable antibacterial and deodourising effects Plasma Duo filter system Quick clean design Drain lift pump as standard Optional drain lift pump Low unit height - minimal intrusion into occupied space High external static pressure Optional high static fan motor Fresh air knockout Branch duct knockout Double thermostat function - control the temp via a sensor in the controller or the unit (wired remote controllers only) Ceiling soiling prevention Replace Technology available Refrigerant volume check function I-See Sensor Duty Standby Operation I-Save - Recalls the preferred (preset) temperature via a single button
Mitsubishi Electric Training Options Mitsubishi Electric has four state-of-the-art training suites based at different locations around the country for your convenience. Providing training for all levels of expertise, our courses are taught by experienced engineers, with a wealth of knowledge and are all CPD accredited.
For bookings please telephone 0161 866 6089
Many of our systems have an energy label of A. These systems meet the criteria of the Energy Technology List and hence could qualify for 100% first year enhanced capital allowances (whole system cost and ‘reasonable’ cost of installation). For further information please go to www.eca.gov.uk
The Forest Stewardship Council (FSC) is an international network promoting responsible management of the world's forest. The paper this catalogue is printed on supports the development of responsible forest management worldwide. The wood comes from FSC certified, well managed forests, company controlled sources and/or recycled material.
Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB. Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB. UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. UK Conditions: Winter; indoor 21˚C DB; outdoor -1˚C WB.
www.green-gateway.co.uk www.sustenergy.org www.mitsubishielectric.com/eco
Note: The fuse rating is only a typical value, it is the responsibility of a qualified electrician/electrical engineer to select the correct cable size and fuse rating based on current regulation and site specific conditions.
The Mitsubishi Electric Air Conditioning Product Catalogue The new 2011 catalogue offers you more information than ever before. That’s because the Mitsubishi Electric air conditioning range contains many new models, plus a fully comprehensive selection of control options to choose from.
If there is anything not covered in the catalogue and you want to know more, simply contact your Mitsubishi Electric supplier who will be delighted to help you. Alternatively, you can visit our website at www.mitsubishielectric.co.uk/aircon for further information.
In addition to increasing the range, we’ve also tried to help you find what you need more quickly and efficiently. We hope you will find it an interesting and informative read.
Contents Page 13 - 62 Page 63 - 131 Page 133 - 243 Page 245 - 264 Page 265 - 307
Page 1
M Series & Mr Slim Split-System Air Conditioning
Air Conditioning Commercial Heating Domestic Heating Photovoltaics
Mitsubishi Electric Split-Systems M Series and Mr Slim
Energy Saving: Reduced Power Consumption & Increased Efficiency
Mitsubishi Electric’s M Series and Mr Slim range of split-systems have benefited from massive investment year on year, the overall result being a vastly improved and more flexible collection of split-systems. One of the most important features of the inverter controlled range is the adoption of A Control, allowing the standardisation of the M Series and Mr Slim ranges, as well as strengthening the remote controller functionality. As a result of this it is possible to connect Mr Slim indoor units to MXZ Multi-Split outdoor units, allowing for complete design flexibility. The Mr Slim Standard Inverter models have further increased the range, offering a lower cost option, whilst still incorporating Mitsubishi Electric’s energy saving inverter technology. These models are now also available as a 3-phase option. A Control is Mitsubishi Electric’s control mechanism for providing standard remote controller functions alongside system diagnostics, fault code monitoring and the ability to interface with the MELANS (Mitsubishi Electric Air Conditioning Network Solution) equipment such as the AG150 Centralised Controller, TG2000, Modbus, Trend, LonWorks® & BACnet® etc.
The entire R410A M Series and Mr Slim ranges are inverter controlled Inverter technology saves energy for two main reasons: 1. The compressor varies its speed to match the cooling or heating load and therefore consumes only the power necessary to match the exact requirement of the room. 2. When an inverter driven air conditioner is operating at partial load, the energy efficiency of the system is significantly higher than at full load. In a typical application, partial load conditions prevail for more than 90% of operation time. A fixed speed system can only operate at 100% capacity and cannot match the annual efficiencies of an inverter system.
The adoption of this technology as standard by Mitsubishi Electric shows our commitment to both increasing your savings, as well as protecting the global environment. Page 4
Page 5
Energy Saving Technology
Total Energy Conservation
Reduced Power Consumption & Increased Efficiency Application of new technologies in Mitsubishi Electric inverter systems significantly enhance the generic benefits of inverter driven systems.
Reluctance DC Rotary Compressors The centralised winding DC motor uses less copper wiring than a conventional version and features a high density, centralised winding method that raises motor winding efficiency to 96%. Units incorporating this motor also benefit from a low starting current as well as a stable set point.
Joint Lap DC Motor This unique “Poki Poki” motor is manufactured using a joint lapping technique. This reliable motor operates based on a high density, high magnetic force, making it extremely efficient.
Highly Efficient Scroll Compressors The scroll compressor is equipped with a ‘Frame Compliance Mechanism’ that allows movement in the axial direction of the frame supporting the moving scroll. This construction realises up to a 27% improvement in compressor efficiency by reducing both leakage and friction losses.
DC Fan Motor A high-efficiency DC motor drives the fan of the outdoor units. It offers up to 60% greater efficiency than an equivalent AC motor.
Simple Partial Switching Method, PAM Control Compared to the conventional active filter method, the simple partial method PAM (Pulse Amplitude Modulation) control found on the new models helps to reduce energy losses. When combined with the Vector-Wave Eco Inverter, PAM control also allows for greater power and efficiency.
Power Receiver and Twin LEV Control Mitsubishi Electric has developed a power receiver and twin LEVs (linear expansion valves) that optimise the performance of the compressor. By ensuring optimum control in response to the operating waveform and outdoor temperature, this technology is tailored to the characteristics of the R410A refrigerant to enhance operating efficiency.
Normal Inver ter vs. PAM
Heat exchanger
PAM adjusts the form of the current wave so that it is close to that of the supply voltage wave. High harmonics are reduced and 98% of the electricity is utilised.
Vector-Wave Eco Inverter This technology uses a specially designed microprocessor to produce the most efficient waveform in response to varying compressor motor rpm. By improving operating efficiency from low to high speeds, annual electricity costs are reduced.
Page 6
Compressor
Power receiver LEV 1
Heat exchanger LEV 2
Page 7
Re-use of Existing Pipework Upgrading Existing R22 & R407c Systems In general the upgrading of existing R22 systems to modern efficient R410A systems has been a difficult or expensive option. This is because the existing pipework would either have to be replaced, or cleaned with dedicated specialist equipment. These actions were necessary as the chlorine residue from R22 system pipework caused chemical reactions with the lubricating oils used in HFC compressors, the result being poor performance and system failure.
Reduced Installation Time & Cost
Mitsubishi Electric’s *1
Replace Technology The M Series*2 & Mr Slim ranges incorporate ‘Replace Technology’ to allow the upgrade of systems using existing pipe work, without the need to apply any special cleaning machines. M Series, S Series, Power Inverter (35/50) and Standard Inverter (100/125/140) utilise Ether oil or the Mitsubishi Electric patented Hard Alkyl Benzene (HAB) oil, a unique oil that is more tolerant of contamination. By combining these oils with developments in oil separator technology it is possible for these models to use existing pipework without any special operations. All other Mr Slim models use a friction reduction “Heat Caulking” method, whereby friction inside the scroll compressor is reduced by coating the edge of the blade, thereby suppressing the increase in temperature that causes refrigerant oil deterioration. *1 Assuming existing pipework is suitable for R410A operational pressures *2 Not available on the MXZ-8B140VA and MXZ-8B160YA Multi-Split outdoor units
The Advantages of Replace Technology For Tenants and Owners Reduces installation time causing less disruption of business Saves on installation costs
For Installers Installation time is reduced significantly It is not necessary to purchase new piping for R410A refrigerant Time-consuming pipe cleaning is not necessary when employing Replace Technology
Page 8
Page 9
Split-System Product Range Overview Outdoor Units
0.9kW Cooling Capacity M Series Inverter (Multi-Split)
M Series Inverter
M Series Inverter
M Series Inverter Multi-Split
M Series Inverter Multi-Split
M Series Inverter Multi-Split
M Series Power Multi
Mr Slim Standard Inverter
Mr Slim Standard Inverter
Mr Slim Power Inverter
Mr Slim Power Inverter
Mr Slim Power Inverter
MUZ-GE25-35VA MUZ-FD25-35VABH SUZ-KA25/35VA2 MXZ-2C52VA
MUZ-GE50VA SUZ-KA50-60VA2
MUZ-GE60-71VA SUZ-KA71VA2
MXZ-3C54VA MXZ-4C71VA
MXZ-4C80VA MXZ-5C100VA
MXZ-6C120VA
MXZ-8B140VA MXZ-8B160YA
PUHZ-P100V/YHA(3)
PUHZ-P125-250V/YHA(3)
PUHZ-RP35/50VHA4
PUHZ-RP60/71VHA4
PUHZ-RP100-250V/YKA
M Series Inverter
MUZ-HC25-35VA(B)
44kW Cooling Capacity Mr Slim Zubadan Inverter
PUHZ-HRP71-125V/YHA2
Indoor Units Model / Size
22 (2.2kW) Multi-Split only
25 (2.5kW)
35 (3.5kW)
50 (5.0kW)
60 (6.0kW)
71 (7.1kW)
100 (10.0kW)
125 (12.5kW)
140 (14.0kW)
200 (19.0kW)
250 (22.0kW)
400 (38.0kW)
500 (44.0kW)
MSZ-HC-VA(B) MSZ-GE-VA MSZ-FD-VA PKA-RP-HAL/KAL MFZ-KA-VA SEZ-KD-VAQ PEAD-RP-JAQ PEA-RP-GAQ SLZ-KA-VAQ PLA-RP-BA(2)(3) PCA-RP-KAQ PCA-RP-HAQ PSA-RP-GA
Page 10
Page 11
The Adaptable Split-System Range
Designed to fit anywhere Available in a variety of options, our Split-System range fits in wherever it’s needed. Indoor units can be four way blow cassettes, ducted, wall, floor or ceiling mounted. Up to eight indoor units can then be connected to a single outdoor unit providing the ideal air conditioning solution.
Simple technology at its best Many of our systems have an energy label of A, are registered on the Energy Technology List and hence qualify for 100% first year enhanced capital allowances (whole system cost and ‘reasonable’ cost of installation). For further information please go to
www.eca.gov.uk
Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB. Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB. UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. UK Conditions: Winter; indoor 21˚C DB; outdoor -1˚C WB.
Page 12
M Series Room Air Conditioning
Air Conditioning Commercial Heating Domestic Heating Photovoltaics
The M Series Range Perfect for Small to Medium Sized Applications Designed to heat or cool small to medium sized applications, the M Series range provides a versatile, yet affordable air conditioning solution. Quick to install and also one of the quietest units on the market (as low as 19dBA*1), this newly designed, attractive range offers the perfect way to ensure a comfortable environment with the minimum of disruption.
Designed to Fit Anywhere
Flexible enough to suit a range of applications, the M Series range includes models that will run up to eight indoor units per outdoor unit. With vastly increased pipe length and height differences over its R407c predecessors, the M Series range is extremely versatile, helping to make system application easier. This diagram shows how a typical multi-split system could be installed into a medium sized office for example.
Surprisingly affordable, the efficiency of the M Series range presents substantial savings in heating mode, when compared with more conventional heating systems. Additional features such as ‘Econo-Cool’ allow airflow to be precisely directed towards users, allowing set temperatures to be raised by 2ºC with no loss in comfort and a 20% gain in energy efficiency.
Highly Energy Efficient The entire M Series range is now available using inverter technology. By matching the compressor speed to the cooling or heating load of the room, up to a 30% reduction in power consumption can be achieved when compared to direct on line models. Increasingly aware of the importance of protecting the environment, the M Series range is made as small as possible to reduce raw material use and the emissions generated in distribution. The whole range also has a very high recovery rate when recycled, so that materials can be used again at the end of the systems life. Many models also make use of a new air filtering system containing the compound Catechin, which helps to improve air quality and prevent the spread of bacteria and viruses. M Series offers the end user some of the highest energy efficiency ratings available, alongside greater application flexibility. Lower running costs and reduced CO2 emissions throughout the life of the system, along with increased comfort for consumers are virtually guaranteed and Mitsubishi Electric has made M Series the natural choice for today’s small to medium sized application market. *1 MSZ-GE22-35VA
Page 14
Page 15
Clean, Comfor table Environment Catechin Filter Catechin is a bioflavonoid that is found in green tea. Bioflavonoids are a group of chemical substances present in many plants, that have both antiviral and antioxidant qualities. In addition to these benefits, Catechin also offers excellent deodorising characteristics; which is why Mitsubishi Electric uses this compound in its air conditioning filters to not only improve air quality, but to also prevent the spread of bacteria and viruses within a room. The filter can be easily removed and when washed regularly, deodorising effectiveness should last for more than 10 years. MSZ-GE22-50VA / MSZ-HC wall mounted and MFZ floor mounted systems are supplied with or have the option of the Catechin filter.
Operating Status Monitoring
“Anti-Allergy Enzyme Filter” mechanism
Monitor lamps located on the right of the indoor unit provide at-a-glance recognition of the air conditioner operating status. When the difference between the set temperature and room temperature is more than 2°C, both monitor lamps will turn on. If it is less than 2°C, only the upper lamp will light.
I Artificial enzyme catalysts on the filament catch the allergens. I The artificial enzyme catalyst helps the chemical reaction with Oxygen and severs the S-S bonds.*1 I Proteins with severed S-S bonds are no longer allergen proteins.
Silent Operation Technological improvements reducing operating sound levels
Only
19dBA in
Quick Clean Design The vane on the MSZ-GE and MSZ-FD wall mounted models easily detaches, allowing access to the louvres. These can then be opened outwards (without any special tools) for quick cleaning of the heat exchanger, fan and air vents. Regular cleaning will increase both operating efficiency and energy-savings.
‘silent mode’
Quick Clean Design can reduce your electricity bill by approximately 30%
Unlike conventional models with a grilled air intake, wall mounted models feature a smoothly contoured, flat panel finish with a top air intake that not only improves aesthetics, but also helps to reduce noise as the heat exchanger area is fully covered. In fact, noise level during normal operation is only 19dBA for the MSZ-GE22-35VA in ‘silent mode’, making it one of the quietest indoor units on the market. This is as a result of the multi-angled heat exchanger having a modified fin shape that reduces air resistance, producing a smoother, quieter flow of air. Alongside this, the wide diameter of the fan produces greater airflow at lower fan speeds and the uneven pitch between each fan blade helps to eliminate unwanted noise. *1 Mites and other allergen protein consist of sulfur atoms (S) that have bonded together.
Page 16
Heat Exchanger
Fan
Electricity bill increases by 5%*1
Electricity bill increases by 25%*1
Air Vent
*1 Electricity bill comparison of operation under a fixed temperature with 8g of soil on the fan and also without.
Page 17
The MSZ-FD Series The "I-See Sensor" automatically moves from side to side, monitoring floor temperature over a wide area of 150°.
The FD Series line-up is engineered for high energy efficiency and low sound levels. The I-See Sensor, Plasma-Duo filter system and other superb functions raise the comfort evel to even greater heights.
Conventional air conditioners control indoor temperature by using only the temperature of the intake air at the top of the room. As a result, the floor level temperature, which exerts such a crucial impact on the temperature that people feel, tends to be overlooked. The I-See Sensor detects the floor temperatures to ensure constant comfort in the living areas.
High Energy Efficiency
Cold air tends to sink to floor level, which is often the cause of over cooling. The I-See Sensor tracks this floor level temperature and adjusts the air outlet temperature accordingly.
With the latest inverter technology, energy efficiency is improved by about 20%. Specifically, more than 5.0 is attained for both the COP and EER for a size 25.
Warm air tends to rise up from the floor level, which often prevents that zone from warming up. The I-See Sensor tracks this floor level temperature and adjusts the air outlet flow accordingly.
Besides a pre-filter, the MSZ-FD is also fitted with two plasma air-purifying functions. These functions are engineered to change air dirt particles from micron to nano-size in scale.
Powerful Heating Capacity The VABH outdoor unit is engineered for use in cold regions (down to -25ºC ambient) and is equipped with a powerful compressor, enabling an improvement in heating capacity. The heating power is raised by about 30% over the standard model and keeps the room comfortable even on cold days.
Plasma Electrode Unit
Field Test Result: Size 35. Sweden, 23rd January 2008
A plasma electrode unit is mounted inside the air conditioner. Electro-discharge is used to generate ozone & plasma. The collaboration between ozone & plasma and two special filters creates a dynamic plasma air cleaning function.
Plasma Air Purification
Plasma Deodorisation
The “Anti-allergen electric enzyme filter” uses the power of the static electricity charged in the filter, as well as plasma generated in the plasma electrode unit to capture the bacteria, pollen and other allergens in the air, which are then neutralised by the enzyme in the filter.
The “Platinum catalyst deodorising filter” captures small foul-smelling substances in the air, then breaks down the source of the odours with the power of the ozone generated in the plasma electrode unit and the platinum catalyst contained in the filter.
Quiet Running A larger line flow fan is included in the FD model. This allows stable capacity with fewer rotations, reducing operating noise.
MSZ-FD Size 25 Size 35
Cooling Heating Cooling Heating
20dBA 20dBA 21dBA 21dBA
Side view of
MSZ-FD Ø106
Page 18
The MSZ-FD is equipped with a “Mould Fighter” function designed to suppress the growth of spores of mould. The ozone generated in the plasma electrode unit attacks the mould spores, reducing mould growth by about 20%. Mould Fighter mechanism Step 1
Step 2
After cooling operation the Plasma Electrode unit fills the inside of the indoor unit with ozone (O3).
The heat exchanger is dried for about 40 mins by the fan mode operation.
Page 19
MXZ Multi-Split Systems The MXZ-8B Power Multi Inver ter Heat Pump Multi-Split Outdoor Units Ideal for apartments or small commercial buildings I
14kW and 15.5kW Inverter Multi Systems, based on Mr Slim Power Inverter technology
I
Ability to connect up to eight indoor units across the M Series and Mr Slim product range within a maximum capacity index of 20.2kW
I
Total Pipe Length of 115m / Height Difference of 30m
I
Single and 3 phase power supplies available
I
Connection of indoor units is through either a 3-way (PAC-AK31BC) or 5-way (PAC-AK52BC) branch box, either singularly or with two in combination
I
Individual control of each indoor unit is now possible (ON/OFF and Setpoint)
I
Low starting and running currents
I
Connection to M-NET system via MAC-399IF interface (one per indoor unit needed)
All Mitsubishi Electric MXZ multi-split outdoor models have an energy label of ‘A’
Example of a Power Multi system using eight indoor units Branch Box
Branch Box
Outdoor Unit
Page 20
Page 21
Excellent Features Available in wall and floor mounted, the M Series range is quiet, economic to run and easy to install. The outdoor units can run up to eight indoor units, all controlled with a simple remote controller. Whatever your requirements may be, Mitsubishi Electric offers the perfect air conditioning solution for any situation.
Contents 24
MSZ-HC-VA(B) Inverter Heat Pump, Wall Mounted System
26
MSZ-GE-VA Inverter Heat Pump, Wall Mounted System
28
MSZ-FD-VA Inverter Heat Pump, Wall Mounted System
30
MFZ-KA-VA Inverter Heat Pump, Floor Mounted System
32
MXZ-C-VA Multi-Split Inverter Heat Pump
34
MXZ-8B-VA/YA Power Multi Inverter Heat Pump
60
Outdoor Units
62
M Series Accessories / Optional Extras
Simple technology at its best Many of our systems have an energy label of A, are registered on the Energy Technology List and hence qualify for 100% first year enhanced capital allowances (whole system cost and ‘reasonable’ cost of installation). For further information please go to
www.eca.gov.uk
Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB. Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB. UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. UK Conditions: Winter; indoor 21˚C DB; outdoor -1˚C WB.
Page 22
Page 23
Dimensions
INDOOR UNIT MSZ-HC25/35VA(B)
Classic Wall Mounted System Mitsubishi Electric’s range of high specification, flat panel wall mounted models make use of inverter technology, whilst providing extremely good value for money, costing approximately 20% less than the MSZ-G equivalent.
Upper View
>
These units have extremely quiet sound levels, whilst also delivering economical air conditioning, with improved COP/EER figures and in many cases corresponding ‘A’ rated energy labels.
Front View
>
Side View
M Series Range
MSZ-HC-VA(B) Inverter Heat Pump
>
* Catechin filter is optional
Technical Information MODEL REFERENCE CAPACITY (kW)
MSZ-HC25VA
MSZ-HC35VAB
Heating (nominal)
3.2 (0.9-4.4)
3.6 (0.9-4.8)
Cooling (nominal)
2.5 (0.9-3.0)
3.4 (1.0-3.7)
Heating (UK)
2.65 (0.75-3.65)
3.0 (0.75-4.0)
Cooling (UK)
2.5 (0.9-3.0)
3.35 (1.0-3.65)
SHF (nominal & UK)
0.79
0.76
COP / EER (nominal)
3.64 / 3.25
3.62 / 3.01
ENERGY LABEL
Heating/Cooling
AIRFLOW (m3/min)
Heating/Cooling - Lo-Mi-Hi-SupHi
PIPE SIZE mm(in) NOISE (dBA) DIMENSIONS (mm)
A /A
A/B
5.1-6.5-7.8-9.1 / 5.3-7.0-8.7-10.5
4.9-6.7-8.0-9.2 / 5.2-6.8-8.4-10.2
Gas
9.52(3/8”)
9.52(3/8”)
Liquid
6.35(1/4”)
6.35(1/4”)
26-32-38-43 / 26-32-38-43
26-32-38-43 / 26-32-38-43
Heating/Cooling - Lo-Mi-Hi-SupHi Width
788
788
Depth
225
225
Height
295
295
WEIGHT (kg)
9
9
Fed by Outdoor Unit
Fed by Outdoor Unit
PHASE
Single
Single
RUNNING CURRENT (A)
0.22
0.22
FUSE RATING (BS88) - HRC (A)
6
6
INTERCONNECTING CABLE No. CORES
4
4
ELECTRICAL SUPPLY
MSZ-HC-VA(B) Inverter Heat Pump
MSZ-HC-VA(B) - INDOOR UNITS
MUZ-HC-VA(B) - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)
Heating/Cooling
WEIGHT (kg) DIMENSIONS (mm)
MUZ-HC25VA
MUZ-HC35VAB
47 / 46
48 / 47
25
25
Width
684
684
Depth
255
255
Height
540
540
220-240v, 50Hz
220-240v, 50Hz
ELECTRICAL SUPPLY PHASE SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A)
Single
Single
0.88 / 0.77
0.995 / 1.13
0.801 / 0.616
0.905 / 0.904
4.2
5.3
4.2 / 3.7 [5.5]
4.8 / 5.3 [6.5]
FUSE RATING (BS88) - HRC (A)
10
10
MAINS CABLE No. CORES
3
3
MAX PIPE LENGTH (m)
10
10
SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling
MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 7m
Page 24
5
5
0.73
0.75
Page 25
Dimensions
INDOOR UNIT MSZ-GE22-50VA
Wall Mounted System The MSZ series has been completely redesigned and features the new Nano Platinum filter system.
Upper View
>
These models offer industry leading noise levels as low as 19dBA and have a distinctively styled front panel that not only looks appealing, but also helps to make cleaning of the unit easier.
Front View
Side View
>
Side View
>
M Series Range
MSZ-GE-VA Inverter Heat Pump
>
* Wide swing & long airflow mode available for MSZ-GE60/71VA * The anti-allergy enzyme filter is optional * Nano Platinum filter available for MSZ-GE60/71VA, Catechin filter available for MSZ-GE22-50VA
Technical Information MSZ-GE-VA - INDOOR UNITS MODEL REFERENCE
MSZ-GE22VA
MSZ-GE25VA
MSZ-GE35VA
MSZ-GE50VA
MSZ-GE60VA
MSZ-GE71VA
Heating (nominal)
3.3 (0.9-4.0)
3.2 (1.3-4.5)
4.0 (1.6-5.3)
5.8 (1.4-7.3)
6.8 (2.0-9.3)
8.1 (2.2-9.9)
Cooling (nominal)
2.2 (0.9-3.0)
2.5 (1.1-3.5)
3.5 (1.1-4.0)
5.0 (1.4-5.5)
6.0 (1.5-7.5)
7.1 (2.4-8.7)
Heating (UK)
2.75 (0.75-3.3)
2.65 (1.1-3.75)
3.3 (1.35-4.4)
4.8 (1.15-6.05)
5.65 (1.65-7.75)
6.75 (1.85-8.25)
Cooling (UK)
7.05 (2.4-8.65)
2.2 (0.9-3.0)
2.5 (1.1-3.45)
3.45 (1.1-3.95)
4.95 (1.4-5.45)
5.95 (1.5-7.45)
SHF (nominal & UK)
-
0.96
0.82
0.76
0.79
0.78
COP / EER (nominal)
-
4.57 / 4.59
4.19 / 4.05
3.71 / 3.30
3.84 / 3.40
3.83 / 3.33
-
A /A
A /A
A /A
A /A
A /A
ENERGY LABEL
Heating/Cooling
AIRFLOW (m3/min)
Heating - Sil-Lo-Mi-Hi-SupHi-SupHiLP
4.1-4.6-6.6-9.1-11.5 4.1-4.8-6.6-9.1-11.5
4.1-4.8-6.7-9.1-11.5 6.5-7.8-9.6-12.2-14.5 9.8-11.3-13.4-15.6-18.3-20.7 10.2-11.5-13.3-15.4-17.8-19.4
Cooling - Sil-Lo-Mi-Hi-SupHi-SupHiLP
4.1-4.6-6.7-9.2-11.3 4.1-4.8-6.7-9.1-11.3
4.1-4.8-6.7-9.1-12.7 6.5-7.8-9.6-11.9-15.1 9.8-11.3-13.4-15.6-18.3-20.7 9.7-11.5-13.3-15.4-17.8-19.4
NOISE (dBA)
DIMENSIONS (mm)
Gas
9.52 (3/8”)
9.52 (3/8”)
9.52 (3/8”)
12.7 (1/2”)
15.88 (5/8”)
15.88 (5/8”)
Liquid
6.35 (1/4”)
6.35 (1/4”)
6.35 (1/4”)
6.35 (1/4”)
6.35 (1/4”)
9.52 (3/8”)
Heating - Sil-Lo-Mi-Hi-SupHi-SupHiLP
19-21-29-36-42
19-21-29-36-42
19-22-30-36-42
28-33-37-43-48
29-37-41-45-49-52
30-37-41-45-49-52
Cooling - Sil-Lo-Mi-Hi-SupHi-SupHiLP
19-21-29-36-42
19-21-29-36-42
19-22-30-36-43
28-33-38-44-49
29-37-41-45-49-52
30-37-41-45-49-53
Width
798
798
798
798
1100
1100
Depth
232
232
232
232
238
238
Height
295
295
295
295
325
325
10
10
10
10
16
16
WEIGHT (kg)
INDOOR UNIT MSZ-GE60/71VA
Upper View
> 1100 1090
5
Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit
ELECTRICAL SUPPLY
Single
Single
Single
Single
Single
Single
FUSE RATING (BS88) – HRC (A)
6
6
6
6
6
6
INTERCONNECTING CABLE No. CORES
4
4
4
4
4
4
N/A Multi-Split Only
MUZ-GE25VA
MUZ-GE35VA
MUZ-GE50VA
MUZ-GE60VA
MUZ-GE71VA
-
48 / 47
48 / 47
56 / 54
55 / 55
55 / 55
PHASE
MUZ-GE-VA - OUTDOOR UNITS
DIMENSIONS (mm)
-
30
33
54
50
53
Width
-
800
800
840
840
840
Depth
-
285
285
330
330
330
Height
-
550
550
850
880
880
-
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
-
0.70 / 0.545
0.955 / 0.865
1.565 / 1.515
1.77 / 1.76
2.11 / 2.13
-
0.637 / 0.436
0.869 / 0.692
1.424 / 1.212
1.611 / 1.408
1.92 / 1.704
ELECTRICAL SUPPLY SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A)
-
3.7
4.6
7.0
7.9
9.4
SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling
-
3.7 / 2.9 [7.4]
4.6 / 4.2 [8.6]
7.0 / 6.8 [13]
7.9 / 7.8 [14.5]
9.4 / 9.3 [16.6]
FUSE RATING (BS88) – HRC (A)
-
10
10
16
16
20
MAINS CABLE No. CORES
-
3
3
3
3
3
MAX PIPE LENGTH (m)
-
20
20
30
30
30
MAX HEIGHT DIFFERENCE (m)
-
12
12
15
15
15
CHARGE R410A (kg) - 7m
-
0.8
1.15
1.55
1.55
1.9
Page 26
Front View
>
238 Air in 5
67
WEIGHT (kg)
12
Heating/Cooling
76
843
181
100
NOISE (dBA)
325
MODEL REFERENCE
MSZ-GE-VA Inverter Heat Pump
PIPE SIZE mm(in)
65 ( 70∞)
Air out
3
CAPACITY (kW)
125 160 184
Page 27
Dimensions
INDOOR UNIT MSZ-FD25/35VA
Wall Mounted System
Upper View
The MSZ-FD series is our most energy efficient M Series wall mounted unit to date. These high COP models feature the new Plasma Duo filter system. They also offer industry leading noise levels and have a distinctively styled front panel that not only looks appealing but also helps to make cleaning of the unit easier.
>
Also incorporated is an ‘I-See Sensor’, providing even temperature distribution and further reducing energy consumption.
Front View
>
Side View
M Series Range
MSZ-FD-VA Inverter Heat Pump
>
Technical Information MODEL REFERENCE CAPACITY (kW)
MSZ-FD25VA
MSZ-FD35VA
Heating (nominal)
3.2 (1.5-6.3)
4.0 (1.3-6.6)
Cooling (nominal)
2.5 (1.1-3.5)
3.5 (0.8-4.0)
Heating (UK)
2.65 (1.25-5.25)
3.3 (1.1-5.5)
Cooling (UK)
2.5 (1.1-3.45)
3.45 (0.8-3.95)
SHF (nominal & UK)
0.85
0.85
COP / EER (nominal)
5.33 / 5.15
4.76 / 4.19
A /A
A /A
4.5-6.7-9.2-12.1 / 4.6-6.3-8.6-11.2
4.7-6.7-9.2-12.5 / 4.6-6.3-8.6-11.2
Gas
9.52 (3/8”)
9.52 (3/8”)
Liquid
6.35 (1/4”)
6.35 (1/4”)
20-29-36-43 / 20-29-36-42
21-29-36-44 / 21-29-36-43
ENERGY LABEL
Heating/Cooling
AIRFLOW (m3/min)
Heating/Cooling - Lo-Mi-Hi-SupHi
PIPE SIZE mm(in)
NOISE (dBA) DIMENSIONS (mm)
Heating/Cooling - Lo-Mi-Hi-SupHi Width
798
798
Depth
257
257
Height
295
295
WEIGHT (kg) ELECTRICAL SUPPLY
12
12
Fed by Outdoor Unit
Fed by Outdoor Unit
Single
Single
FUSE RATING (BS88) – HRC (A)
6
6
INTERCONNECTING CABLE No. CORES
4
4
PHASE
MSZ-FD-VA Inverter Heat Pump
MSZ-FD-VA - INDOOR UNITS
MUZ-FD-VABH - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)
Heating/Cooling
WEIGHT (kg) DIMENSIONS (mm)
MUZ-FD25VABH
MUZ-FD35VABH
46 / 46
50 / 47
36
36
Width
800
800
Depth
285
285
Height
550
550
220-240v, 50Hz
220-240v, 50Hz
ELECTRICAL SUPPLY SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A)
0.60 / 0.485
0.84 / 0.835
0.546 / 0.388
0.764 / 0.668
2.9
3.9
2.9 / 2.4 [10]
3.9 / 3.8 [10.5]
FUSE RATING (BS88) – HRC (A)
10
16
MAINS CABLE No. CORES
3
3
MAX PIPE LENGTH (m)
20
20
SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling
MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 7m
Page 28
12
12
1.15
1.15
Page 29
Dimensions INDOOR UNIT MFZ-KA25-50VA
Floor Mounted System The MFZ-KA-VA series is extremely versatile and is designed for wall attached installation at floor level. The auto swing vane provides a more natural and comfortable airflow throughout the room and the lightweight, compact design makes installation easy.
* The anti-allergy enzyme filter is optional
Upper View
>
Front View
>
M Series Range
MFZ-KA-VA Inverter Heat Pump
Technical Information
MFZ-KA-VA - INDOOR UNITS CAPACITY (kW)
MFZ-KA25VA
MFZ-KA35VA
MFZ-KA50VA
Heating (nominal)
3.4 (0.9-5.1)
4.0 (0.9-6.2)
6.0 (0.9-7.9)
Cooling (nominal)
2.5 (0.9-3.4)
3.5 (0.9-3.9)
4.8 (0.9-5.4)
Heating (UK)
2.85 (0.75-4.25)
3.3 (0.75-5.15)
5.0 (0.75-6.55)
Cooling (UK)
4.75 (0.9-5.35)
2.5 (0.9-3.35)
3.45 (0.9-3.85)
SHF (nominal & UK)
0.66
0.65
0.63
COP / EER (nominal)
4.07 / 4.31
3.64 / 3.21
3.23 / 3.10
ENERGY LABEL
Heating/Cooling
AIRFLOW (m3/min)
Heating/Cooling - Lo-Mi-Hi-SupHi
PIPE SIZE mm(in)
NOISE (dBA) DIMENSIONS (mm)
A /A
A /A
C/B
5.0-6.2-7.6-9.4 / 4.8-5.8-7.1-8.9
5.2-6.2-7.8-9.5 / 5.0-6.1-7.4-9.1
7.4-8.8-9.8-12.3 / 7.1-7.9-9.2-11.2
Gas
9.52 (3/8”)
9.52 (3/8”)
12.7 (1/2”)
Liquid
6.35 (1/4”)
6.35 (1/4”)
6.35 (1/4”)
22-27-32-37 / 22-27-32-37
25-28-33-38 / 23-28-33-38
32-35-39-44 / 32-35-39-43
Heating/Cooling - Lo-Mi-Hi-SupHi Width
700
700
700
Depth
200
200
200
Height
600
600
600
14
14
14
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
Single
Single
Single
FUSE RATING (BS88) – HRC (A)
6
6
6
INTERCONNECTING CABLE No. CORES
4
4
4
SUZ-KA25VA2
SUZ-KA35VA2
SUZ-KA50VA2
46 / 46
48 / 47
55 / 53
33
37
53
Width
800
800
840
Depth
285
285
330
Height
550
550
850
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
0.835 / 0.58
1.10 / 1.09
1.86 / 1.55
0.76 / 0.46
1.00 / 0.87
1.69 / 1.24
3.65
4.75
6.75
3.85 / 3.25 [8.4]
4.95 / 4.75 [9.4]
6.55 / 6.95 [16.2]
FUSE RATING (BS88) - HRC (A)
10
10
20
MAINS CABLE No. CORES
3
3
3
MAX PIPE LENGTH (m)
20
20
30
WEIGHT (kg) ELECTRICAL SUPPLY PHASE
Side View
> MFZ-KA-VA Inverter Heat Pump
MODEL REFERENCE
SUZ-KA-VA2 - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)
Heating/Cooling
WEIGHT (kg) DIMENSIONS (mm)
ELECTRICAL SUPPLY SYSTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling
MAX HEIGHT DIFFERENCE (m)
12
12
15
CHARGE R410A (kg) - 7m
0.8
1.05
1.6
Page 30
Page 31
OUTDOOR UNIT MXZ-2C52VA
Multi-Split Units
Upper View
>
Front View
>
Side View
>
>
Side View
>
The multi-split system allows up to six M Series or Mr Slim wall mounted, cassette, ducted, floor or ceiling mounted indoor unit heat pumps of different capacities to be operated from a single outdoor unit. This makes it an economic answer in multi-room applications, whilst also offering space saving benefits.
OUTDOOR UNIT MXZ-3C54VA / MXZ-4C71VA
MXZ-6C120VA
2
2-3
2-4
2-4
2-5
2-6
6.4 (1.0-7.0)
7.0 (2.6-9.0)
8.6 (3.4-10.7)
9.4 (3.4-11.6)
12.0 (4.1-14.0)
14.0 (3.5-16.5)
Cooling (nominal)
5.2 (1.1-6.0)
5.4 (2.9-6.8)
7.1 (3.7-8.8)
8.0 (3.7-9.2)
10.0 (3.9-11.0)
12.0 (3.5-13.5)
Heating (UK)
5.3 (0.85-5.8)
5.8 (2.15-7.5)
7.15 (2.85-8.9)
7.8 (2.85-9.65)
9.95 (3.4-11.65)
11.65 (2.9-13.7)
Cooling (UK)
5.15 (1.1-5.95)
5.35 (2.9-6.75)
7.05 (3.65-8.75)
7.95 (3.65-9.15)
9.9 (3.85-10.9)
11.9 (3.45-13.4)
COP / EER (nominal)
Outdoor Only
3.98 / 4.00
5.04 / 4.23
4.78 / 4.54
4.87 / 4.09
4.23 / 3.57
3.88 / 3.21
ENERGy LABEL
Heating/Cooling
A /A
A /A
A /A
A /A
A /A
A /A
MAX AIRFLOW (m3/min)
Heating/Cooling
NOISE (dBA)
Heating/Cooling - Sil-Hi
DIMENSIONS (mm)
33.3 / 32.9
43 / 42.1
43 / 42.1
43.8 / 42.2
59.3 / 56.6
59.5 / 69.9
49-50 / 46-49
48-51 / 45-47
48-52 / 45-48
46-48 / 44-46
47-54 / 46-51
53-57 / 51-55
Width
800
840
840
900
900
900
Depth
285
330
330
320
320
320
Height
550
710
710
900
900
1070
WEIGHT (kg)
38
57
58
67
68
88
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
Heating/Cooling (nominal)
1.61 / 1.30
1.465 / 1.19
1.705 / 1.68
1.93 / 1.955
2.835 / 2.88
3.47 / 3.61
Heating/Cooling (UK)
1.47 / 1.04
1.33 / 0.95
1.55 / 1.34
1.76 / 1.56
2.58 / 2.30
3.16 / 2.89
7.22
6.43
7.49
8.59
12.45
15.85
7.22 / 5.83 [10.2]
6.43 / 5.23 [15]
7.49 / 7.38 [15]
8.48 / 8.59 [17.4]
12.45 / 12.30 [18.4]
15.24 / 15.85 [27]
ELECTRICAL SUPPLy POWER INPUT (kW)
STARTING CURRENT (A) RUNNING CURRENT (A) [MAX] Heating/Cooling INTERCONNECTING CABLE No. CORES
4 Core
4 Core
4 Core
4 Core
4 Core
4 Core
TOTAL PIPE LENGTH (m)
30
50
60
70
80
80
MAX PIPE LENGTH PER INDOOR UNIT (m)
20
25
25
25
25
25
15 (10 if OU higher than IU)
15 (10 if OU higher than IU)
15 (10 if OU higher than IU)
15 (10 if OU higher than IU)
15 (10 if OU higher than IU)
15 (10 if OU higher than IU)
1.3 [20m]
2.7 [40m]
2.7 [40m]
3.5 [40m]
4.0 [40m]
5.0 [60m]
16
25
25
25
25
40
MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) [Precharged Length] FUSE RATING (BS88) – HRC (A)
Page 32
17.7
240 710
315
440
45
360
84
250
500
Front View
900
Air in
Air out
Side View
>
200
270 Air in
> 30
320
10
Indoor and outdoor connect wiring (35 x 53) hole
E connection for MXZ-5B100VA
88 E unit connection D unit connection C unit connection B unit connection A unit connection
23
317
OUTDOOR UNIT MXZ-6C120VA Upper View
>
Front View
>
Side View
>
Page 33
MXZ-C-VA Multi-Split Inverter Heat Pump (5.2 -12kW )
MXZ-5C100VA
B unit connection
900
MXZ-4C80VA
C unit connection
23.1
405
MXZ-4C71VA
D unit connection
597
Heating (nominal)
MXZ-3C54VA
66.3
132
MXZ-2C52VA
NUMBER OF CONNECTABLE INDOOR UNITS
200 35
>
460
MODEL REFERENCE
Upper View
11
MXZ-C-VA - OUTDOOR UNITS
13
D connection for MXZ-4B71VA
45
*1 Combined max running current of all indoors on system must not exceed 3A if PEAD-RP is used
330
27.1 Indoor and outdoor connect wiring 39 x 27 hole
(Bolt pitch) 387
MXZ-6C120VA
30
OUTDOOR UNIT MXZ-4C80VA / MXZ-5C100VA
355
MXZ-5C100VA
30
200
299
24
MXZ-4C80VA
840
A unit connection
35
MXZ-4C71VA
Air out
74
MXZ-3C54VA
CAPACITy (kW)
13.3
Air in
WALL MOUNTED FLOOR MOUNTED DUCTED CEILING CASSETTE CEILING SUSPENDED MSZ-GE22/25/35VA SEZ-KD25/35VAQ MSZ-FD25/35VA MFZ-KA25/35VA SLZ-KA25/35VAQ MSZ-EF25/35VEB MSZ-GE22/25/35/50VA SLZ-KA25/35/50VAQ SEZ-KD25/35/50VAQ PCA-RP50KAQ MSZ-FD25/35VA MFZ-KA25/35/50VA PLA-RP50BA PEAD-RP50JAQ*1 MSZ-EF25/35/50VEB MSZ-GE22/25/35/50/60VA SEZ-KD25/35/50/60VAQ SLZ-KA25/35/50VAQ MFZ-KA25/35/50VA PCA-RP50/60KAQ MSZ-FD25/35VA PLA-RP50/60BA PEAD-RP50JAQ*1 MSZ-EF25/35/50VEB MSZ-GE22/25/35/50/60/71VA SEZ-KD25/35/50/60/71VAQ SLZ-KA25/35/50VAQ PCA-RP50/60/71KAQ MSZ-FD25/35VA MFZ-KA25/35/50VA PEAD-RP50/60/71JAQ*1 PLA-RP50/60/71BA(2) MSZ-EF25/35/50VEB MSZ-GE22/25/35/50/60/71VA SEZ-KD25/35/50/60/71VAQ SLZ-KA25/35/50VAQ MFZ-KA25/35/50VA MSZ-FD25/35VA PCA-RP50/60/71KAQ PEAD-RP50/60/71JAQ*1 PLA-RP50/60/71BA(2) MSZ-EF25/35/50VEB MSZ-GE22/25/35/50/60/71VA SEZ-KD25/35/50/60/71VAQ SLZ-KA25/35/50VAQ MFZ-KA25/35/50VA MSZ-FD25/35VA PCA-RP50/60/71KAQ PEAD-RP50/60/71JAQ*1 PLA-RP50/60/71BA(2) MSZ-EF25/35/50VEB
MXZ-2C52VA
Air in
20.3
MULTI-SPLIT - INDOOR UNITS MODEL REFERENCE
171
288
31.3
16.8
Technical Information
500 233.1
Front View
396
169 63.2
> 360.6 (Bolt Pitch)
Upper View
17.7
I
16
I
16
I
Up to six indoor units may be connected to a single outdoor unit Energy saving inverter controlled outdoor unit adjusts compressor performance to economically match the demand for heating and cooling Units may be added within the capacity of the system as requirements change Capacities of indoor units may be mixed to suit individual rooms New size 80, 100 and 120 have current limit adjustment for managing energy costs. They also feature a wiring/piping correction function to analyse the system for connection errors via the press of a single button
27
I
40
I
M Series Range
MXZ-C-VA Inverter Heat Pump (5.2 - 12kW)
Dimensions
OUTDOOR UNIT MXZ-8B140VA / MXZ-8B160YA
Inverter Heat Pump Multi-Split Units
Upper View
>
The Power Multi systems allow up to eight M Series or Mr Slim cassette, ducted, floor, ceiling or wall mounted indoor units of different capacities to be operated from a single outdoor unit, making use of two types of branch box to achieve this. This makes them an economic answer in multi-room applications and ideal for apartments or small commercial buildings. I
14 and 15.5kW Inverter Multi Systems, based on Mr Slim Power Inverter technology
I
Total Pipe length of 115m / Height difference of 30m
I
Individual control of each indoor unit is now possible (ON/OFF & Setpoint)
I
Low starting and running currents
I
Connection to M-NET system via MAC-399IF interface (one per indoor unit)
I
Current limit adjustment for managing energy costs
Front View
>
Side View
>
M Series Range
MXZ-8B-VA/YA Power Multi (14-15.5kW)
Dimensions
Technical Information MULTI-SPLIT - INDOOR UNITS WALL MOUNTED
FLOOR MOUNTED
DUCTED
CEILING CASSETTE
MXZ-8B140VA
MSZ-GE22/25/35/50/60/71VA MSZ-FD25/35VA MSZ-EF25/35/50VEB
MFZ-KA25/35/50VA
SEZ-KD25/35/50/60/71VAQ PEAD-RP50/60/71JAQ*1
SLZ-KA25/35/50VAQ PLA-RP35/50/60/71BA(2) PLA-RP100BA(3)*2
MXZ-8B160YA
MSZ-GE22/25/35/50/60/71VA MSZ-FD25/35VA MSZ-EF25/35/50VEB
MFZ-KA25/35/50VA
SEZ-KD25/35/50/60/71VAQ PEAD-RP50/60/71JAQ*1
SLZ-KA25/35/50VAQ PLA-RP35/50/60/71BA(2) PLA-RP100BA(3)*2
PAC-AK31BC - BRANCH BOX
POWER SUPPLY TO BRANCH BOX
15.5
POWER SUPPLY TO INDOOR UNITS
Heating (UK)
13.3
14.95
PIPE SIZE mm(in) Main Outdoor Side - Gas
Cooling (UK)
13.9
15.4
COP / EER (nominal)
Outdoor Only
3.91 / 3.52
3.61 / 3.21
ENERGY LABEL
Heating/Cooling
A /A
A /A
100
106
52 / 47-50
54 / 48-51
55
TOTAL PIPE LENGTH - Branch Boxes to Indoor Unit (m)
60
MAX HEIGHT DIFFERENCE - Outdoor Unit to Branch Box (m)
30
MAX HEIGHT DIFFERENCE - Branch Box to Indoor Unit (m)
15
DIMENSIONS (mm)
950
Width
450
330
Depth
280
Height
1350
1350
Height
198
129
139
220-240v, 50Hz
380-415v, 50Hz
Single
3
Heating/Cooling (nominal)
3.90 / 3.79
4.80 / 4.64
Heating/Cooling (UK)
3.55 / 3.03
4.37 / 3.71
14
7
17.05 / 16.55 [29.5]
7.00 / 6.77 [13]
4 Core
4 Core
115
115
15 (from Branch Box)
15 (from Branch Box)
70
70
RUNNING CURRENT (A) [MAX] Heating/Cooling INTERCONNECTING CABLE No. CORES TOTAL PIPE LENGTH (m) MAX PIPE LENGTH PER INDOOR UNIT (m) FURTHEST PIPE LENGTH - Outdoor to Indoor (m) MAX HEIGHT DIFFERENCE - Outdoor to Indoor (m)
30 (20 if OU lower than IU) 30 (20 if OU lower than IU)
BRANCH BOX PAC-AK52BC Front View
>
Side View
>
Upper View
>
320 450
PAC-AK52BC
91 73
55
95 61
280 79
50
39
34
to indoor unit
NUMBER OF CONNECTABLE INDOOR UNITS POWER SUPPLY TO BRANCH BOX POWER SUPPLY TO INDOOR UNITS
1-5 From Outdoor Unit From Branch Box
PIPE SIZE mm(in) Main Outdoor Side - Gas
15.88(5/8”)
PIPE SIZE mm(in) Main Outdoor Side - Liquid
9.52(3/8”)
MAX PIPE LENGTH - Outdoor Unit to Branch Box (m)
55
TOTAL PIPE LENGTH - Branch Boxes to Indoor Unit (m)
60
MAX HEIGHT DIFFERENCE - Outdoor Unit to Branch Box (m)
30
MAX HEIGHT DIFFERENCE - Branch Box to Indoor Unit (m)
15
DIMENSIONS (mm)
Width
450
MAX HEIGHT DIFFERENCE - Indoor to Indoor (m)
12
12
CHARGE R410A (kg) - 40m
8.5
8.5
Depth
280
FUSE RATING (BS88) – HRC (A)
40
25
Height
198
Page 34
21
25 75
12
PAC-AK52BC - BRANCH BOX MODEL REFERENCE
25 75
9.52(3/8”)
MAX PIPE LENGTH - Outdoor Unit to Branch Box (m)
330
STARTING CURRENT (A)
25
15.88(5/8”)
950
PHASE
70
From Branch Box
Width
ELECTRICAL SUPPLY
POWER INPUT (kW)
From Outdoor Unit
Depth
WEIGHT (kg)
A
B
E E
D
B
C C
D
A A
B
402
DIMENSIONS (mm)
Heating/Cooling - Sil-Hi
A
B
C C
25
25 75
25 75
25 75
25
21
75
24
NOISE (dBA)
PIPE SIZE mm(in) Main Outdoor Side - Liquid
1-3
12
Page 35
MXZ-8B-VA/YA Power Multi Inverter Heat Pump (14-15.5kW)
18.0
14.0
320
39
34
402
16.0
50
24
Heating (nominal) Cooling (nominal)
79
68
CAPACITY (kW)
PAC-AK31BC
NUMBER OF CONNECTABLE INDOOR UNITS
61
>
68
2-8
280
95
Upper View
39
2-8
65
NUMBER OF CONNECTABLE INDOOR UNITS
MODEL REFERENCE
198
MXZ-8B160YA
91 73
>
to indoor unit
39
MXZ-8B140VA
MAX AIRFLOW (m3/min)
450 205
65
MODEL REFERENCE
Side View
70
MXZ-8B-VA/YA - OUTDOOR UNITS
Can only be connected using a PAC-AK52BC with a PAC-AK52YP-E pipe
>
35
capacity of indoor units must not exceed 100% if PEAD-RP is used
*2
Front View
35
*1 Total
BRANCH BOX PAC-AK31BC
198
MODEL REFERENCE
Multi-Split Systems 8 Outdoor Units
32 Indoor Units MSZ-GE-VA Series
MXZ-2C52VA Inverter Multi unit MSZ-FD-VA Series
MXZ-6C120VA Inverter Multi unit
MFZ-KA-VA Series
MXZ-3C54VA MXZ-4C71VA Inverter Multi units
SEZ-KD-VAQ Series
MXZ-8B140VA MXZ-8B160YA Power Multi units
Multi-Split systems allow up to eight M Series or Mr Slim cassette, ducted, floor, ceiling or wall mounted indoor units of different capacities to be operated from a single outdoor unit.
PEAD-RP-JAQ Series
MXZ-4C80VA MXZ-5C100VA Inverter Multi units
SLZ-KA-VAQ Series
PLA-RP-BA(2)(3) Series
PCA-RP-KAQ Series
Page 36
Page 37
Multi-Split System Combinations 1 Outdoor Unit Indoor unit combination
1 Outdoor Unit
2 Indoor Units Cooling / Heating Capacity (kW) Unit A
+ + + + + +
22 25 35 25 35 35
2.20 2.20 1.93 2.50 2.13 2.60
/ / / / / /
3.05 2.90 2.43 3.15 2.63 3.20
2.20 2.50 3.07 2.50 2.98 2.60
/ / / / / /
3.05 3.30 3.87 3.15 3.68 3.20
Indoor unit combination
Up to 3 Indoor Units Cooling / Heating Capacity (kW) Unit A
Unit B
Unit C
1 ROOM 2.20 2.50 3.50 5.00
22 25 35 50
/ / / /
3.30 3.60 4.00 6.80
+ + + + + + + + + +
2.20 2.20 2.08 1.65 2.50 2.25 1.80 2.70 2.22 2.70
22 25 35 50 25 35 50 35 50 50
/ / / / / / / / / /
3.30 3.14 2.62 2.08 3.40 2.83 2.27 3.40 2.80 3.40
2.20 2.50 3.32 3.75 2.50 3.15 3.60 2.70 3.18 2.70
/ / / / / / / / / /
3.30 3.56 4.18 4.72 3.40 3.97 4.53 3.40 4.00 3.40
3 ROOMS 22 22 22 22 22 22 22 22 25 25 25 25
+ + + + + + + + + + + +
22 22 22 22 25 25 25 35 25 25 25 35
Page 38
+ + + + + + + + + + + +
22 25 35 50 25 35 50 35 25 35 50 35
Unit C
1.80 1.72 1.50 1.26 1.65 1.45 1.22 1.29 1.80 1.59 1.35 1.42
/ / / / / / / / / / / /
2.27 2.20 1.95 1.64 2.11 1.88 1.59 1.67 2.33 2.06 1.75 1.84
1.80 1.72 1.50 1.26 1.88 1.65 1.39 2.05 1.80 1.59 1.35 1.99
/ / / / / / / / / / / /
2.27 2.20 1.95 1.64 2.40 2.13 1.80 2.66 2.33 2.06 1.75 2.58
1.80 1.96 2.39 2.87 1.88 2.30 2.78 2.05 1.80 2.22 2.70 1.99
/ / / / / / / / / / / /
2.27 2.50 3.10 3.72 2.40 2.99 3.61 2.66 2.33 2.88 3.50 2.58
Unit A
Unit B
Unit C
Unit D
22 + 22 + 22 + 22
1.78 / 2.15
1.78 / 2.15
1.78 / 2.15
1.78 / 2.15
22 + 22 + 22 + 25
1.72 / 2.08
1.72 / 2.08
1.72 / 2.08
22 + 22 + 22 + 35
1.55 / 1.87
1.55 / 1.87
1.55 / 1.87
22 + 22 + 22 + 50
1.35 / 1.63
1.35 / 1.63
1.35 / 1.63
3.06 / 3.71
22 + 22 + 25 + 25
1.66 / 2.01
1.66 / 2.01
1.89 / 2.29
1.89 / 2.29
Unit D
22 + 22 + 25 + 35
1.50 / 1.82
1.50 / 1.82
1.71 / 2.07
2.39 / 2.89
22 + 22 + 25 + 50
1.31 / 1.59
1.31 / 1.59
1.49 / 1.81
2.98 / 3.61
Indoor unit combination
Cooling / Heating Capacity (kW) Unit A
Unit B
35 + 60
2.91 / 3.46
4.99 / 5.94
35 + 71
2.61 / 3.10
5.29 / 6.30
1.95 / 2.36
50 + 50
3.95 / 4.70
3.95 / 4.70
2.46 / 2.98
50 + 60
3.64 / 4.27
4.36 / 5.13
50 + 71
3.31 / 3.88
4.69 / 5.52
60 + 60
4.00 / 4.70
4.00 / 4.70
60 + 71
3.66 / 4.31
4.34 / 5.09
22 + 22 + 22
2.20 / 2.90
2.20 / 2.90
2.20 / 2.90
22 + 22 + 25
2.20 / 2.81
2.20 / 2.81
2.50 / 3.19
22 + 22 + 35
2.14 / 2.56
2.14 / 2.56
3.41 / 4.08
1.83 / 2.20
1.83 / 2.20
4.15 / 5.00
22
2.20 / 3.30
25
2.50 / 3.60
22 + 22 + 35 + 35
1.37 / 1.66
1.37 / 1.66
2.18 / 2.64
2.18 / 2.64
35
3.50 / 4.00
22 + 25 + 25 + 25
1.61 / 1.95
1.83 / 2.22
1.83 / 2.22
1.83 / 2.22
50
5.00 / 7.20
22 + 25 + 25 + 35
1.46 / 1.77
1.66 / 2.01
1.66 / 2.01
2.32 / 2.81
60
6.00 / 7.90
22 + 25 + 25 + 50
1.28 / 1.55
1.45 / 1.76
1.45 / 1.76
2.91 / 3.52
22 + 25 + 35 + 35
1.34 / 1.62
1.52 / 1.84
2.12 / 2.57
2.12 / 2.57
Unit C
22 + 22
2.20 / 3.30
2.20 / 3.30
25 + 25 + 25 + 25
1.78 / 2.15
1.78 / 2.15
1.78 / 2.15
1.78 / 2.15
22 + 25
2.20 / 3.23
2.50 / 3.67
25 + 25 + 25 + 35
1.61 / 1.95
1.61 / 1.95
1.61 / 1.95
2.26 / 2.74
22 + 22 + 60
1.67 / 1.99
1.67 / 1.99
4.56 / 5.42
22 + 35
2.20 / 2.97
3.50 / 4.73
25 + 25 + 25 + 50
1.42 / 1.72
1.42 / 1.72
1.42 / 1.72
2.84 / 3.44
22 + 22 + 71
1.53 / 1.80
1.53 / 1.80
4.94 / 5.80
22 + 50
2.08 / 2.63
4.72 / 5.97
25 + 25 + 35 + 35
1.48 / 1.79
1.48 / 1.79
2.07 / 2.51
2.07 / 2.51
22 + 25 + 25
2.20 / 2.72
2.50 / 3.09
2.50 / 3.09
22 + 60
1.82 / 2.31
4.98 / 6.29 22 + 25 + 35
2.07 / 2.50
2.35 / 2.84
3.29 / 3.97
25 + 25
2.50 / 3.60
2.50 / 3.60
25 + 35
2.50 / 3.29
3.50 / 4.61
22 + 25 + 50
1.79 / 2.13
2.04 / 2.42
4.07 / 4.85
25 + 50
2.27 / 2.87
4.53 / 5.73
22 + 25 + 60
1.64 / 1.93
1.87 / 2.20
4.49 / 5.27
25 + 60
2.00 / 2.53
4.80 / 6.07
22 + 25 + 71
1.49 / 1.75
1.69 / 1.99
4.81 / 5.66
35 + 35
3.40 / 4.30
3.40 / 4.30
22 + 35 + 35
1.87 / 2.25
2.97 / 3.58
2.97 / 3.58
22 + 35 + 50
1.64 / 1.93
2.62 / 3.07
3.74 / 4.39
22 + 35 + 60
1.50 / 1.77
2.39 / 2.81
4.10 / 4.82
22 + 35 + 71
1.38 / 1.62
2.19 / 2.57
4.44 / 5.21
22 + 50 + 50
1.44 / 1.70
3.28 / 3.85
3.28 / 3.85
22 + 50 + 60
1.33 / 1.57
3.03 / 3.56
3.64 / 4.27
22 + 50 + 71
1.23 / 1.45
2.80 / 3.29
3.97 / 4.67
25 + 25 + 25
2.50 / 3.00
2.50 / 3.00
2.50 / 3.00
35 + 50
2.80 / 3.54
4.00 / 5.06
35 + 60
2.51 / 3.17
4.29 / 5.43
50 + 50
3.40 / 4.30
3.40 / 4.30
50 + 60
3.09 / 3.91
3.71 / 4.69
60 + 60
3.40 / 4.30
3.40 / 4.30
MXZ-4C80VA 1 Outdoor Unit Indoor unit combination
Up to 4 Indoor Units Cooling / Heating Capacity (kW) Unit A
Unit B
1 ROOM
Unit C
Unit D
22 + 22 + 22
2.20 / 2.87
2.20 / 2.87
2.20 / 2.87
22
2.20 / 3.30
22 + 22 + 25
2.20 / 2.74
2.20 / 2.74
2.50 / 3.12
25
2.50 / 3.60
22 + 22 + 35
1.98 / 2.39
1.98 / 2.39
3.15 / 3.81
35
3.50 / 4.00
22 + 22 + 50
1.66 / 2.01
1.66 / 2.01
3.78 / 4.57
50
5.00 / 7.20
25 + 25 + 35
2.29 / 2.76
2.29 / 2.76
3.21 / 3.87
22 + 22 + 60
1.50 / 1.82
1.50 / 1.82
4.10 / 4.96
60
6.00 / 7.90
25 + 25 + 50
1.98 / 2.35
1.98 / 2.35
3.95 / 4.70
22 + 25 + 25
2.17 / 2.63
2.47 / 2.99
2.47 / 2.99
71
7.10 / 8.60
25 + 25 + 60
1.82 / 2.14
1.82 / 2.14
4.36 / 5.13
22 + 25 + 35
1.90 / 2.31
2.16 / 2.62
3.03 / 3.67
22 + 25 + 50
1.61 / 1.95
1.83 / 2.22
3.66 / 4.43
25 + 25 + 71
1.65 / 1.94
1.65 / 1.94
4.69 / 5.52
22 + 25 + 60
1.46 / 1.77
1.66 / 2.01
3.98 / 4.82
25 + 35 + 35
2.08 / 2.47
2.91 / 3.46
2.91 / 3.46
22 + 35 + 35
1.70 / 2.06
2.70 / 3.27
2.70 / 3.27
25 + 35 + 50
1.82 / 2.14
2.55 / 2.99
3.64 / 4.27
22 + 35 + 50
1.46 / 1.77
2.32 / 2.81
3.32 / 4.02
25 + 35 + 60
1.67 / 1.96
2.33 / 2.74
4.00 / 4.70
22 + 35 + 60
1.34 / 1.62
2.12 / 2.57
3.64 / 4.41
1.53 / 1.79
2.14 / 2.51
4.34 / 5.09
2 ROOMS 22 + 22
2.20 / 3.30
2.20 / 3.30
22 + 25
2.20 / 3.23
2.50 / 3.67
22 + 35
2.20 / 2.89
3.50 / 4.61
Unit D
3 ROOMS
22 + 22 + 50
3 ROOMS
2 ROOMS 22 22 22 22 25 25 25 35 35 50
Unit B
2 ROOMS
MXZ-3C54VA 1 Outdoor Unit
Cooling / Heating Capacity (kW)
1 ROOM 2.20 / 3.30 2.50 / 3.60 3.50 / 4.00
2 ROOMS 22 22 22 25 25 35
Up to 4 Indoor Units
Unit A
Unit B
1 ROOM 22 25 35
Indoor unit combination
Cooling / Heating Capacity (kW)
4 ROOMS
MXZ-4C71VA
MXZ-2C52VA
Indoor unit combination
22 + 50 + 50
1.28 / 1.55
2.91 / 3.52
2.91 / 3.52
22 + 50
2.20 / 2.51
5.00 / 5.69
25 + 35 + 71
25 + 25 + 25
2.37 / 2.87
2.37 / 2.87
2.37 / 2.87
22 + 60
2.09 / 2.52
5.71 / 6.88
25 + 50 + 50
1.60 / 1.88
3.20 / 3.76
3.20 / 3.76
25 + 25 + 35
2.09 / 2.53
2.09 / 2.53
2.92 / 3.54
22 + 71
1.87 / 2.22
6.03 / 7.18
25 + 50 + 60
1.48 / 1.74
2.96 / 3.48
3.56 / 4.18
25 + 25 + 50
1.78 / 2.15
1.78 / 2.15
3.55 / 4.30
25 + 25
2.50 / 3.60
2.50 / 3.60
35 + 35 + 35
2.65 / 3.13
2.65 / 3.13
2.65 / 3.13
25 + 25 + 60
1.61 / 1.95
1.61 / 1.95
3.87 / 4.69
25 + 35
2.50 / 3.17
3.50 / 4.43
25 + 35 + 35
1.87 / 2.26
2.62 / 3.17
2.62 / 3.17
35 + 35 + 50
2.33 / 2.74
2.33 / 2.74
3.33 / 3.92
25 + 50
2.50 / 2.87
5.00 / 5.73
25 + 35 + 50
1.61 / 1.95
2.26 / 2.74
3.23 / 3.91
25 + 60
2.29 / 2.76
5.51 / 6.64
35 + 35 + 60
2.15 / 2.53
2.15 / 2.53
3.69 / 4.34
25 + 35 + 60
1.48 / 1.79
2.07 / 2.51
3.55 / 4.30
4.03 / 4.73
2.84 / 3.44
5.84 / 6.95
1.99 / 2.33
2.84 / 3.44
2.06 / 2.45
1.99 / 2.33
1.42 / 1.72
25 + 71
35 + 35 + 71
25 + 50 + 50
2.07 / 2.44
2.96 / 3.48
2.96 / 3.48
35 + 35 + 35
2.37 / 2.87
2.37 / 2.87
2.37 / 2.87
35 + 35 + 50
2.07 / 2.51
2.07 / 2.51
2.96 / 3.58
1.93 / 2.27
2.76 / 3.24
3.31 / 3.89
35 + 35
3.50 / 4.00
3.50 / 4.00
35 + 50 + 50
35 + 50
3.21 / 3.87
4.59 / 5.53
35 + 50 + 60
Page 39
Indoor unit combination
Cooling / Heating Capacity (kW) Unit A
Unit B
Unit C
Indoor unit combination
Unit D
Cooling / Heating Capacity (kW) Unit A
Unit B
22 + 22 + 22 + 22
1.95 / 2.35
1.95 / 2.35
1.95 / 2.35
1.95 / 2.35
22 + 22
2.20 / 3.30
2.20 / 3.30
22 + 22 + 22 + 25
1.90 / 2.27
1.90 / 2.27
1.90 / 2.27
2.16 / 2.58
22 + 25
2.20 / 3.23
2.50 / 3.67
22 + 22 + 22 + 35
1.73 / 2.05
22 + 35
2.20 / 2.89
3.50 / 4.61
22 + 50
2.17 / 2.57
4.93 / 5.83
22 + 60
2.07 / 2.71
5.63 / 7.39
22 + 22 + 22 + 50
1.52 / 1.78
1.73 / 2.05 1.52 / 1.78
1.73 / 2.05 1.52 / 1.78
2.75 / 3.26 3.45 / 4.05
22 + 22 + 22 + 60
1.40 / 1.64
1.40 / 1.64
1.40 / 1.64
3.81 / 4.48
22 + 22 + 22 + 71
1.28 / 1.51
1.28 / 1.51
1.28 / 1.51
4.15 / 4.87
22 + 22 + 25 + 25
1.84 / 2.20
1.84 / 2.20
2.09 / 2.50
2.09 / 2.50
22 + 22 + 25 + 35
1.68 / 1.99
1.68 / 1.99
1.91 / 2.26
2.68 / 3.16
22 + 22 + 25 + 50
1.48 / 1.74
1.48 / 1.74
1.68 / 1.97
3.36 / 3.95
25 + 35
2.50 / 3.17
3.50 / 4.43
22 + 22 + 25 + 60
1.36 / 1.60
1.36 / 1.60
1.55 / 1.82
3.72 / 4.37
25 + 50
2.43 / 2.97
4.87 / 5.93
22 + 22 + 25 + 71
1.26 / 1.48
1.26 / 1.48
1.43 / 1.68
4.06 / 4.77
25 + 60
2.29 / 3.09
5.51 / 7.41
22 + 22 + 35 + 35
Unit C
2 ROOMS
4 ROOMS
1.54 / 1.81
1.54 / 1.81
2.46 / 2.89
2.46 / 2.89
22 + 22 + 35 + 50
1.36 / 1.60
1.36 / 1.60
2.17 / 2.55
3.10 / 3.64
22 + 22 + 35 + 60
1.27 / 1.49
1.27 / 1.49
2.01 / 2.37
3.45 / 4.06
22 + 22 + 50 + 50
1.22 / 1.44
1.22 / 1.44
2.78 / 3.26
2.78 / 3.26
22 + 25 + 25 + 25
1.79 / 2.13
2.04 / 2.42
2.04 / 2.42
2.04 / 2.42
22 + 25 + 25 + 35
1.63 / 1.93
1.86 / 2.20
1.86 / 2.20
2.60 / 3.07
22 + 25 + 25 + 50
1.44 / 1.70
1.64 / 1.93
1.64 / 1.93
3.28 / 3.85
22 + 71 25 + 25
25 + 71 35 + 35 35 + 50 35 + 60 35 + 71
1.92 / 2.51 2.50 / 3.60
2.14 / 2.76 3.50 / 4.00 3.21 / 4.32 2.98 / 3.91 2.81 / 3.50
Indoor unit combination
Cooling / Heating Capacity (kW) Unit A
Unit B
Unit C
25 + 25 + 25
2.50 / 3.00
2.50 / 3.00
2.50 / 3.00
25 + 25 + 35
2.32 / 2.74
2.32 / 2.74
25 + 25 + 50
2.10 / 2.45
2.10 / 2.45
25 + 25 + 60
1.98 / 2.32
25 + 25 + 71
Unit B
Unit C
Unit D
22 + 22 + 35 + 71
1.39 / 1.61
1.39 / 1.61
2.22 / 2.57
4.50 / 5.21
3.25 / 3.83
22 + 22 + 50 + 50
1.45 / 1.68
1.45 / 1.68
3.30 / 3.82
3.30 / 3.82
4.20 / 4.90
22 + 22 + 50 + 60
1.37 / 1.57
1.37 / 1.57
3.12 / 3.57
3.74 / 4.29
1.98 / 2.32
4.75 / 5.56
22 + 22 + 50 + 71
1.31 / 1.47
1.31 / 1.47
2.97 / 3.33
4.22 / 4.73
1.84 / 2.19
1.84 / 2.19
5.22 / 6.22
22 + 25 + 25 + 25
1.93 / 2.27
2.19 / 2.58
2.19 / 2.58
2.19 / 2.58
25 + 35 + 35
2.16 / 2.55
3.02 / 3.57
3.02 / 3.57
22 + 25 + 25 + 35
1.79 / 2.10
2.03 / 2.38
2.03 / 2.38
2.85 / 3.34
25 + 35 + 50
1.98 / 2.32
2.77 / 3.25
3.95 / 4.64
22 + 25 + 25 + 50
1.62 / 1.91
1.84 / 2.17
1.84 / 2.17
3.69 / 4.34
25 + 35 + 60
1.85 / 2.21
2.60 / 3.09
4.45 / 5.30
22 + 25 + 25 + 60
1.53 / 1.80
1.74 / 2.05
1.74 / 2.05
4.18 / 4.91
25 + 35 + 71
1.74 / 2.06
2.43 / 2.89
4.93 / 5.85
22 + 25 + 25 + 71
1.45 / 1.69
1.64 / 1.92
1.64 / 1.92
4.67 / 5.46
25 + 50 + 50
1.80 / 2.16
3.60 / 4.32
3.60 / 4.32
22 + 25 + 35 + 35
1.67 / 1.96
1.90 / 2.22
2.66 / 3.11
2.66 / 3.11
25 + 50 + 60
1.70 / 2.02
3.41 / 4.04
4.09 / 4.84
22 + 25 + 35 + 50
1.53 / 1.80
1.74 / 2.05
2.44 / 2.86
3.48 / 4.09
25 + 50 + 71
1.59 / 1.88
3.18 / 3.77
4.52 / 5.35
22 + 25 + 35 + 60
1.46 / 1.70
1.65 / 1.94
2.32 / 2.71
3.97 / 4.65
25 + 60 + 60
1.60 / 1.90
3.85 / 4.55
3.85 / 4.55
22 + 25 + 35 + 71
1.38 / 1.58
1.57 / 1.80
2.20 / 2.52
4.45 / 5.10
25 + 60 + 71
1.51 / 1.76
3.62 / 4.23
4.28 / 5.01
22 + 25 + 50 + 50
1.42 / 1.65
1.62 / 1.87
3.23 / 3.74
3.23 / 3.74
35 + 35 + 35
2.87 / 3.33
2.87 / 3.33
2.87 / 3.33
22 + 25 + 50 + 60
1.35 / 1.54
1.53 / 1.75
3.06 / 3.50
3.67 / 4.20
2.60 / 3.09
2.60 / 3.09
3.71 / 4.42
22 + 25 + 50 + 71
1.28 / 1.44
1.46 / 1.64
2.92 / 3.27
4.14 / 4.65
22 + 35 + 35 + 35
1.58 / 1.85
2.51 / 2.95
2.51 / 2.95
2.51 / 2.95
22 + 35 + 35 + 50
1.46 / 1.70
2.32 / 2.71
2.32 / 2.71
3.31 / 3.87
22 + 35 + 35 + 60
1.39 / 1.59
2.21 / 2.53
2.21 / 2.53
3.79 / 4.34
22 + 35 + 35 + 71
1.31 / 1.48
2.08 / 2.36
2.08 / 2.36
4.23 / 4.79
22 + 35 + 50 + 50
1.35 / 1.54
2.14 / 2.45
3.06 / 3.50
3.06 / 3.50
22 + 35 + 50 + 60
1.29 / 1.45
2.05 / 2.31
2.93 / 3.29
3.52 / 3.95
25 + 25 + 25 + 25
2.15 / 2.50
2.15 / 2.50
2.15 / 2.50
2.15 / 2.50
25 + 25 + 25 + 35
2.00 / 2.34
2.00 / 2.34
2.00 / 2.34
2.80 / 3.28
25 + 25 + 25 + 50
1.82 / 2.12
1.82 / 2.12
1.82 / 2.12
3.64 / 4.24
25 + 25 + 25 + 60
1.72 / 2.02
1.72 / 2.02
1.72 / 2.02
4.13 / 4.84
25 + 25 + 25 + 71
1.63 / 1.88
1.63 / 1.88
1.63 / 1.88
4.62 / 5.35
25 + 25 + 35 + 35
1.88 / 2.19
1.88 / 2.19
2.63 / 3.06
2.63 / 3.06
25 + 25 + 35 + 50
1.72 / 2.02
1.72 / 2.02
2.41 / 2.83
3.44 / 4.04
25 + 25 + 35 + 60
1.64 / 1.90
1.64 / 1.90
2.29 / 2.66
3.93 / 4.54
2.50 / 3.60
3.50 / 4.00 4.59 / 6.18 5.12 / 6.69 5.69 / 7.10
50 + 50
4.15 / 5.30
4.15 / 5.30
35 + 35 + 50
3.91 / 4.82
4.69 / 5.78
35 + 35 + 60
2.45 / 2.91
2.45 / 2.91
4.20 / 4.98
22 + 25 + 25 + 60
1.33 / 1.57
1.52 / 1.78
1.52 / 1.78
3.64 / 4.27
50 + 60
22 + 25 + 35 + 35
1.50 / 1.77
1.71 / 2.01
2.39 / 2.81
2.39 / 2.81
50 + 71
3.68 / 4.38
5.22 / 6.22
35 + 35 + 71
2.31 / 2.71
2.31 / 2.71
4.68 / 5.49
22 + 25 + 35 + 50
1.33 / 1.57
1.52 / 1.78
2.12 / 2.49
3.03 / 3.56
60 + 60
4.45 / 5.30
4.45 / 5.30
35 + 50 + 50
2.39 / 2.83
3.41 / 4.04
3.41 / 4.04
22 + 25 + 35 + 60
1.24 / 1.46
1.41 / 1.65
1.97 / 2.32
3.38 / 3.97
60 + 71
4.12 / 4.85
4.88 / 5.75
35 + 50 + 60
2.24 / 2.66
3.21 / 3.79
3.85 / 4.55
22 + 35 + 35 + 35
1.39 / 1.63
2.20 / 2.59
2.20 / 2.59
2.20 / 2.59
71 + 71
4.55 / 5.30
4.55 / 5.30
35 + 50 + 71
2.11 / 2.47
3.01 / 3.53
4.28 / 5.01
22 + 35 + 35 + 50
1.24 / 1.45
1.97 / 2.32
1.97 / 2.32
2.82 / 3.31
35 + 60 + 60
2.12 / 2.48
3.64 / 4.26
3.64 / 4.26
25 + 25 + 25 + 25
1.98 / 2.35
1.98 / 2.35
1.98 / 2.35
1.98 / 2.35
3.40 / 3.98
4.02 / 4.70
25 + 25 + 25 + 35
1.82 / 2.14
1.82 / 2.14
2.55 / 2.99
1.98 / 2.32
1.82 / 2.14
35 + 60 + 71
25 + 25 + 25 + 50
1.60 / 1.88
1.60 / 1.88
1.60 / 1.88
3.20 / 3.76
25 + 25 + 25 + 60
1.48 / 1.74
1.48 / 1.74
1.48 / 1.74
3.56 / 4.18
25 + 25 + 35 + 35
1.67 / 1.96
1.67 / 1.96
2.33 / 2.74
25 + 25 + 35 + 50
1.48 / 1.74
1.48 / 1.74
25 + 35 + 35 + 35
1.54 / 1.81
35 + 35 + 35 + 35
2.00 / 2.35
Indoor unit combination
2.20 / 2.90
2.20 / 2.90
2.20 / 2.90
50 + 50 + 50
3.13 / 3.67
3.13 / 3.67
3.13 / 3.67
22 + 22 + 25
2.20 / 2.81
2.20 / 2.81
2.50 / 3.19
50 + 50 + 60
2.94 / 3.44
2.94 / 3.44
3.53 / 4.13
2.33 / 2.74
22 + 22 + 35
2.12 / 2.53
2.12 / 2.53
3.37 / 4.03
50 + 50 + 71
2.75 / 3.22
2.75 / 3.22
3.90 / 4.57
2.07 / 2.44
2.96 / 3.48
22 + 22 + 50
1.92 / 2.25
1.92 / 2.25
4.36 / 5.11
2.15 / 2.53
2.15 / 2.53
2.15 / 2.53
22 + 22 + 60
1.82 / 2.12
1.82 / 2.12
4.96 / 5.77
4 ROOMS
2.00 / 2.35
2.00 / 2.35
2.00 / 2.35
22 + 22 + 71
1.68 / 1.99
1.68 / 1.99
5.43 / 6.42
22 + 22 + 22 + 22
2.00 / 2.50
2.00 / 2.50
2.00 / 2.50
2.00 / 2.50
22 + 25 + 25
2.20 / 2.72
2.50 / 3.09
2.50 / 3.09
22 + 22 + 22 + 25
1.98 / 2.42
1.98 / 2.42
1.98 / 2.42
2.25 / 2.75
22 + 25 + 35
2.09 / 2.47
2.38 / 2.80
3.33 / 3.93
22 + 22 + 22 + 35
1.87 / 2.18
1.87 / 2.18
1.87 / 2.18
2.98 / 3.47
22 + 25 + 50
1.88 / 2.20
2.14 / 2.50
4.28 / 5.00
22 + 22 + 22 + 50
1.69 / 1.97
1.69 / 1.97
1.69 / 1.97
3.84 / 4.48
25 + 25 + 35 + 71
1.54 / 1.76
1.54 / 1.76
2.15 / 2.47
4.37 / 5.01
22 + 25 + 60
1.77 / 2.08
2.01 / 2.36
4.82 / 5.66
22 + 22 + 22 + 60
1.59 / 1.87
1.59 / 1.87
1.59 / 1.87
4.33 / 5.10
25 + 25 + 50 + 50
1.58 / 1.83
1.58 / 1.83
3.17 / 3.67
3.17 / 3.67
22 + 25 + 71
1.64 / 1.96
1.86 / 2.22
5.29 / 6.32
22 + 22 + 22 + 71
1.49 / 1.75
1.49 / 1.75
1.49 / 1.75
4.82 / 5.65
25 + 25 + 50 + 60
1.52 / 1.72
1.52 / 1.72
3.03 / 3.44
3.64 / 4.13
22 + 35 + 35
1.94 / 2.30
3.08 / 3.65
3.08 / 3.65
22 + 22 + 25 + 25
1.94 / 2.34
1.94 / 2.34
2.21 / 2.66
2.21 / 2.66
25 + 25 + 50 + 71
1.43 / 1.61
1.43 / 1.61
2.87 / 3.22
4.07 / 4.57
22 + 35 + 50
1.77 / 2.08
2.81 / 3.30
4.02 / 4.72 22 + 22 + 25 + 35
1.84 / 2.14
1.84 / 2.14
2.09 / 2.43
2.93 / 3.40
25 + 35 + 35 + 35
1.77 / 2.08
2.48 / 2.91
2.48 / 2.91
2.48 / 2.91
22 + 35 + 60
1.65 / 1.97
2.63 / 3.14
4.51 / 5.38 22 + 22 + 25 + 50
1.66 / 1.94
1.66 / 1.94
1.89 / 2.21
3.78 / 4.41
25 + 35 + 35 + 50
1.64 / 1.90
2.29 / 2.66
2.29 / 2.66
3.28 / 3.79
22 + 35 + 71
1.55 / 1.86
2.46 / 2.95
4.99 / 5.99 22 + 22 + 25 + 60
1.57 / 1.82
1.57 / 1.82
1.78 / 2.07
4.28 / 4.98
25 + 35 + 35 + 60
1.55 / 1.77
2.17 / 2.48
2.17 / 2.48
3.72 / 4.26
22 + 50 + 50
1.60 / 1.91
3.65 / 4.34
3.65 / 4.34 1.68 / 1.96
4.77 / 5.58
2.07 / 2.32
4.19 / 4.70
4.14 / 4.95
1.48 / 1.73
2.07 / 2.32
3.45 / 4.13
1.48 / 1.73
1.48 / 1.66
1.52 / 1.82
22 + 22 + 25 + 71
25 + 35 + 35 + 71
22 + 50 + 60 22 + 50 + 71
1.43 / 1.68
3.25 / 3.81
4.62 / 5.41
22 + 22 + 35 + 35
1.72 / 2.01
1.72 / 2.01
2.73 / 3.19
2.73 / 3.19
35 + 35 + 35 + 35
2.35 / 2.75
2.35 / 2.75
2.35 / 2.75
2.35 / 2.75
22 + 22 + 35 + 50
1.57 / 1.82
1.57 / 1.82
2.50 / 2.90
3.57 / 4.15
35 + 35 + 35 + 50
2.17 / 2.48
2.17 / 2.48
2.17 / 2.48
3.10 / 3.55
22 + 22 + 35 + 60
1.49 / 1.74
1.49 / 1.74
2.37 / 2.77
4.06 / 4.75
35 + 35 + 35 + 60
2.08 / 2.33
2.08 / 2.33
2.08 / 2.33
3.56 / 4.00
Up to 5 Indoor Units Cooling / Heating Capacity (kW) Unit A
1 ROOM
3 ROOMS 22 + 22 + 22
MXZ-5C100VA 1 Outdoor Unit
Unit B
Unit C
Unit D
22
2.20 / 3.30
25
2.50 / 3.60
35
3.50 / 4.00
50
5.00 / 7.20
60
6.00 / 7.90
22 + 60 + 60
1.44 / 1.69
3.93 / 4.61
3.93 / 4.61
71
7.10 / 8.60
22 + 60 + 71
1.35 / 1.58
3.69 / 4.31
4.36 / 5.10
Page 40
Unit D
Cooling / Heating Capacity (kW) Unit A
Unit D
6.18 / 8.09
6.06 / 7.84
Indoor unit combination
Page 41
Indoor unit combination
Cooling / Heating Capacity (kW)
MXZ-6C120VA 1 Outdoor Unit
Unit A
Unit B
Unit C
Unit D
Up to 6 Indoor Units
Indoor unit combination
Cooling / Heating Capacity (kW)
22 + 22 + 22 + 22 + 22
2.00 / 2.40
2.00 / 2.40
2.00 / 2.40
2.00 / 2.40
2.00 / 2.40
22 + 22 + 22 + 22 + 25
1.95 / 2.34
1.95 / 2.34
1.95 / 2.34
1.95 / 2.34
2.21 / 2.65
22 + 22 + 22 + 22 + 35
1.79 / 2.15
1.79 / 2.15
1.79 / 2.15
1.79 / 2.15
2.85 / 3.41
1 ROOM
22 + 22 + 22 + 22 + 50
1.59 / 1.91
1.59 / 1.91
1.59 / 1.91
1.59 / 1.91
3.62 / 4.35
22
2.20 / 3.30
22 + 22 + 22 + 22 + 60
1.49 / 1.78
1.49 / 1.78
1.49 / 1.78
1.49 / 1.78
4.05 / 4.86
25
2.50 / 3.60
22 + 22 + 22 + 22 + 71
1.38 / 1.66
1.38 / 1.66
1.38 / 1.66
1.38 / 1.66
4.47 / 5.36
35
3.50 / 4.00
22 + 22 + 22 + 25 + 25
1.90 / 2.28
1.90 / 2.28
1.90 / 2.28
2.16 / 2.59
2.16 / 2.59
50
5.00 / 7.20
22 + 22 + 22 + 25 + 35
1.75 / 2.10
1.75 / 2.10
1.75 / 2.10
1.98 / 2.38
2.78 / 3.33
60
6.00 / 7.90
1.56 / 1.87
1.56 / 1.87
1.56 / 1.87
1.77 / 2.13
3.55 / 4.26
22 + 22 + 22 + 25 + 60
1.46 / 1.75
1.46 / 1.75
1.46 / 1.75
1.66 / 1.99
3.97 / 4.77
22 + 22 + 22 + 25 + 71
1.36 / 1.63
1.36 / 1.63
1.36 / 1.63
1.54 / 1.85
4.38 / 5.26
22 + 22 + 22 + 35 + 35
1.62 / 1.94
1.62 / 1.94
1.62 / 1.94
2.57 / 3.09
2.57 / 3.09
22 + 22 + 22 + 35 + 50
1.46 / 1.75
1.46 / 1.75
1.46 / 1.75
2.32 / 2.78
3.31 / 3.97
22 + 22 + 22 + 35 + 60
1.37 / 1.64
1.37 / 1.64
1.37 / 1.64
2.17 / 2.61
3.73 / 4.47
22 + 22 + 22 + 35 + 71
1.28 / 1.53
1.28 / 1.53
1.28 / 1.53
2.03 / 2.44
4.13 / 4.95
22 + 22 + 25 + 25 + 25
1.85 / 2.22
1.85 / 2.22
2.10 / 2.52
2.10 / 2.52
2.10 / 2.52
22 + 22 + 25 + 25 + 35
1.71 / 2.05
1.71 / 2.05
1.94 / 2.33
1.94 / 2.33
2.71 / 3.26
22 + 22 + 25 + 25 + 50
1.53 / 1.83
1.53 / 1.83
1.74 / 2.08
1.74 / 2.08
3.47 / 4.17
22 + 22 + 25 + 25 + 60
1.43 / 1.71
1.43 / 1.71
1.62 / 1.95
1.62 / 1.95
3.90 / 4.68
22 + 22 + 25 + 25 + 71
1.33 / 1.60
1.33 / 1.60
1.52 / 1.82
1.52 / 1.82
4.30 / 5.16
22 + 22 + 25 + 35 + 35
1.58 / 1.90
1.58 / 1.90
1.80 / 2.16
2.52 / 3.02
2.52 / 3.02
Unit A
71
Unit B
Unit C
Unit D
Cooling / Heating Capacity (kW) Unit A
Unit B
Unit C
22 + 25 + 50
2.02 / 2.65
2.29 / 3.02
4.59 / 6.03
22 + 25 + 60
1.97 / 2.49
2.24 / 2.83
5.38 / 6.79
22 + 25 + 71
1.83 / 2.31
2.08 / 2.63
5.90 / 7.46
22 + 35 + 35
2.13 / 2.75
3.39 / 4.38
3.39 / 4.38
22 + 35 + 50
1.97 / 2.49
3.14 / 3.96
4.49 / 5.65
22 + 35 + 60
1.84 / 2.31
2.93 / 3.68
5.03 / 6.31
22 + 35 + 71
1.72 / 2.17
2.73 / 3.45
5.55 / 6.99
22 + 50 + 50
1.77 / 2.25
4.02 / 5.12
4.02 / 5.12
22 + 50 + 60
1.68 / 2.12
3.83 / 4.81
4.59 / 5.77
22 + 50 + 71
1.60 / 2.00
3.64 / 4.55
5.16 / 6.45
22 + 60 + 60
1.61 / 2.00
4.39 / 5.45
4.39 / 5.45
22 + 60 + 71
1.54 / 1.90
4.20 / 5.18
4.97 / 6.13
22 + 71 + 71
1.48 / 1.78
4.76 / 5.76
4.76 / 5.76
25 + 25 + 25
2.50 / 3.60
2.50 / 3.60
2.50 / 3.60
2.41 / 3.29
2.41 / 3.29
3.38 / 4.61
Unit E
5 ROOMS
22 + 22 + 22 + 25 + 50
Indoor unit combination
7.10 / 8.60
2 ROOMS 22 + 22
2.20 / 3.30
2.20 / 3.30
22 + 25
2.20 / 3.23
2.50 / 3.67
22 + 35
2.20 / 2.89
3.50 / 4.61
25 + 25 + 35
22 + 50
2.20 / 2.57
5.00 / 5.83
25 + 25 + 50
2.40 / 2.95
2.40 / 2.95
4.80 / 5.90
22 + 60
2.20 / 2.79
6.00 / 7.61
25 + 25 + 60
2.20 / 2.75
2.20 / 2.75
5.29 / 6.60
22 + 71
2.06 / 2.63
6.64 / 8.47
25 + 25 + 71
2.02 / 2.58
2.02 / 2.58
5.75 / 7.33
25 + 25
2.50 / 3.60
2.50 / 3.60
25 + 35 + 35
2.34 / 3.05
3.28 / 4.27
3.28 / 4.27
25 + 35
2.50 / 3.17
3.50 / 4.43
25 + 35 + 50
2.20 / 2.75
3.09 / 3.85
4.41 / 5.50
2.50 / 3.00
5.00 / 6.00
25 + 35 + 60
2.04 / 2.58
2.86 / 3.62
4.90 / 6.20
2.47 / 3.18
5.93 / 7.62
25 + 35 + 71
1.91 / 2.42
2.67 / 3.39
5.42 / 6.88
22 + 22 + 25 + 35 + 50
1.43 / 1.71
1.43 / 1.71
1.62 / 1.95
2.27 / 2.73
3.25 / 3.90
25 + 50
22 + 22 + 25 + 35 + 60
1.34 / 1.61
1.34 / 1.61
1.52 / 1.83
2.13 / 2.56
3.66 / 4.39
25 + 60
22 + 22 + 35 + 35 + 35
1.48 / 1.77
1.48 / 1.77
2.35 / 2.82
2.35 / 2.82
2.35 / 2.82
25 + 71
2.29 / 2.92
6.51 / 8.28
25 + 50 + 50
1.98 / 2.52
3.96 / 5.04
3.96 / 5.04
22 + 22 + 35 + 35 + 50
1.34 / 1.61
1.34 / 1.61
2.13 / 2.56
2.13 / 2.56
3.05 / 3.66
35 + 35
3.50 / 4.00
3.50 / 4.00
25 + 50 + 60
1.89 / 2.37
3.78 / 4.74
4.53 / 5.69
22 + 25 + 25 + 25 + 25
1.80 / 2.16
2.05 / 2.46
2.05 / 2.46
2.05 / 2.46
2.05 / 2.46
35 + 50
3.46 / 4.45
4.94 / 6.35
25 + 50 + 71
1.80 / 2.23
3.60 / 4.45
5.11 / 6.32
22 + 25 + 25 + 25 + 35
1.67 / 2.00
1.89 / 2.27
1.89 / 2.27
1.89 / 2.27
2.65 / 3.18
35 + 60
3.21 / 4.09
5.49 / 7.01
25 + 60 + 60
1.81 / 2.24
4.34 / 5.38
4.34 / 5.38
22 + 25 + 25 + 25 + 50
1.50 / 1.80
1.70 / 2.04
1.70 / 2.04
1.70 / 2.04
3.40 / 4.08
35 + 71
3.00 / 3.73
6.10 / 7.57
25 + 60 + 71
1.73 / 2.12
4.15 / 5.08
4.92 / 6.01
22 + 25 + 25 + 25 + 60
1.40 / 1.68
1.59 / 1.91
1.59 / 1.91
1.59 / 1.91
3.82 / 4.59
50 + 50
4.45 / 5.65
4.45 / 5.65
22 + 25 + 25 + 25 + 71
25 + 71 + 71
1.66 / 2.01
4.72 / 5.70
4.72 / 5.70
1.31 / 1.57
1.49 / 1.79
1.49 / 1.79
1.49 / 1.79
4.23 / 5.07
50 + 60
4.23 / 5.14
5.07 / 6.16
22 + 25 + 25 + 35 + 35
1.55 / 1.86
1.76 / 2.11
1.76 / 2.11
2.46 / 2.96
2.46 / 2.96
35 + 35 + 35
3.20 / 4.00
3.20 / 4.00
3.20 / 4.00
50 + 71
3.97 / 4.67
5.63 / 6.63
22 + 25 + 25 + 35 + 50
1.40 / 1.68
1.59 / 1.91
1.59 / 1.91
2.23 / 2.68
3.18 / 3.82
35 + 35 + 50
2.86 / 3.62
2.86 / 3.62
4.08 / 5.17
60 + 60
4.80 / 5.65
4.80 / 5.65 35 + 35 + 60
2.69 / 3.42
2.69 / 3.42
4.62 / 5.86
60 + 71
4.44 / 5.18
5.26 / 6.12 35 + 35 + 71
2.56 / 3.20
2.56 / 3.20
5.19 / 6.50
22 + 25 + 25 + 35 + 60
1.32 / 1.58
1.50 / 1.80
1.50 / 1.80
2.10 / 2.51
3.59 / 4.31
22 + 25 + 35 + 35 + 35
1.45 / 1.74
1.64 / 1.97
2.30 / 2.76
2.30 / 2.76
2.30 / 2.76
22 + 25 + 35 + 35 + 50
1.32 / 1.58
1.50 / 1.80
2.10 / 2.51
2.10 / 2.51
2.99 / 3.59
35 + 50 + 50
2.64 / 3.32
3.78 / 4.74
3.78 / 4.74
22 + 35 + 35 + 35 + 35
1.36 / 1.63
2.16 / 2.59
2.16 / 2.59
2.16 / 2.59
2.16 / 2.59
35 + 50 + 60
2.53 / 3.14
3.62 / 4.48
4.34 / 5.38
25 + 25 + 25 + 25 + 25
2.00 / 2.40
2.00 / 2.40
2.00 / 2.40
2.00 / 2.40
2.00 / 2.40
35 + 50 + 71
2.42 / 2.96
3.46 / 4.23
4.92 / 6.01
25 + 25 + 25 + 25 + 35
1.85 / 2.22
1.85 / 2.22
1.85 / 2.22
1.85 / 2.22
2.59 / 3.11
35 + 60 + 60
2.44 / 2.98
4.18 / 5.11
4.18 / 5.11
25 + 25 + 25 + 25 + 50
1.67 / 2.00
1.67 / 2.00
1.67 / 2.00
1.67 / 2.00
3.33 / 4.00
35 + 60 + 71
2.34 / 2.83
4.01 / 4.84
4.75 / 5.73
25 + 25 + 25 + 25 + 60
1.56 / 1.88
1.56 / 1.88
1.56 / 1.88
1.56 / 1.88
3.75 / 4.50
25 + 25 + 25 + 25 + 71
35 + 71 + 71
2.25 / 2.69
4.57 / 5.46
4.57 / 5.46
1.46 / 1.75
1.46 / 1.75
1.46 / 1.75
1.46 / 1.75
4.15 / 4.98
25 + 25 + 25 + 35 + 35
1.72 / 2.07
1.72 / 2.07
1.72 / 2.07
2.41 / 2.90
25 + 25 + 25 + 35 + 50
1.56 / 1.88
1.56 / 1.88
1.56 / 1.88
25 + 25 + 25 + 35 + 60
1.47 / 1.76
1.47 / 1.76
1.47 / 1.76
71 + 71
4.85 / 5.65
4.85 / 5.65
3 ROOMS 22 + 22 + 22
2.20 / 3.30
2.20 / 3.30
2.20 / 3.30
22 + 22 + 25
2.20 / 3.25
2.20 / 3.25
2.50 / 3.70
22 + 22 + 35
2.09 / 3.06
2.09 / 3.06
3.32 / 4.87
2.41 / 2.90
22 + 22 + 50
2.08 / 2.71
2.08 / 2.71
4.73 / 6.17
50 + 50 + 50
3.53 / 4.37
3.53 / 4.37
3.53 / 4.37
2.19 / 2.63
3.13 / 3.75
22 + 22 + 60
2.03 / 2.54
2.03 / 2.54
5.54 / 6.92
50 + 50 + 60
3.41 / 4.16
3.41 / 4.16
4.09 / 4.99
2.06 / 2.47
3.53 / 4.24
22 + 22 + 71
1.86 / 2.35
1.86 / 2.35
5.99 / 7.59
50 + 50 + 71
3.27 / 3.95
3.27 / 3.95
4.65 / 5.61
3.29 / 3.94
3.95 / 4.73
3.95 / 4.73
3.83 / 4.53
3.83 / 4.53
3.83 / 4.53
25 + 25 + 35 + 35 + 35
1.61 / 1.94
1.61 / 1.94
2.26 / 2.71
2.26 / 2.71
2.26 / 2.71
22 + 25 + 25
2.20 / 3.21
2.50 / 3.65
2.50 / 3.65
50 + 60 + 60
25 + 25 + 35 + 35 + 50
1.47 / 1.76
1.47 / 1.76
2.06 / 2.47
2.06 / 2.47
2.94 / 3.53
22 + 25 + 35
2.20 / 2.98
2.50 / 3.38
3.50 / 4.74
60 + 60 + 60
Page 42
Unit D
Page 43
Indoor unit combination
Cooling / Heating Capacity (kW) Unit A
Unit B
Unit C
Unit D
4 ROOMS 22 + 22 + 22 + 22 22 + 22 + 22 + 25
2.20 / 2.85 2.20 / 2.80
2.20 / 2.85 2.20 / 2.80
2.20 / 2.85 2.20 / 2.80
Indoor unit combination
2.20 / 2.85
Unit A
Unit B
Unit C
Unit D
22 + 35 + 35 + 60
1.55 / 1.91
2.46 / 3.04
2.46 / 3.04
4.22 / 5.21
22 + 35 + 35 + 71
1.46 / 1.78
2.32 / 2.83
2.32 / 2.83
4.70 / 5.75
2.50 / 3.19 22 + 35 + 50 + 50
22 + 22 + 22 + 35 22 + 22 + 22 + 50 22 + 22 + 22 + 60 22 + 22 + 22 + 71 22 + 22 + 25 + 25 22 + 22 + 25 + 35
2.18 / 2.61 1.95 / 2.37 1.83 / 2.23 1.70 / 2.10 2.20 / 2.74 2.14 / 2.56
2.18 / 2.61 1.95 / 2.37 1.83 / 2.23 1.70 / 2.10 2.20 / 2.74 2.14 / 2.56
2.18 / 2.61 1.95 / 2.37 1.83 / 2.23 1.70 / 2.10 2.50 / 3.11 2.43 / 2.91
Cooling / Heating Capacity (kW)
1.51 / 1.85
2.41 / 2.94
3.44 / 4.20
3.44 / 4.20
3.47 / 4.17 22 + 35 + 50 + 60
1.42 / 1.74
2.26 / 2.77
3.23 / 3.95
3.88 / 4.74
22 + 35 + 50 + 71
1.33 / 1.56
2.12 / 2.48
3.03 / 3.54
4.31 / 5.03
4.44 / 5.39 5.00 / 6.10 5.49 / 6.79 2.50 / 3.11 3.40 / 4.07
22 + 35 + 60 + 60 22 + 50 + 50 + 50 25 + 25 + 25 + 25
1.34 / 1.57 1.38 / 1.61 2.50 / 3.00
2.14 / 2.49 3.14 / 3.66 2.50 / 3.00
3.66 / 4.27 3.14 / 3.66 2.50 / 3.00
3.66 / 4.27 3.14 / 3.66 2.50 / 3.00
22 + 22 + 25 + 50
1.90 / 2.33
1.90 / 2.33
2.16 / 2.65
4.33 / 5.29
25 + 25 + 25 + 35
2.32 / 2.80
2.32 / 2.80
2.32 / 2.80
3.25 / 3.91
22 + 22 + 25 + 60
1.79 / 2.20
1.79 / 2.20
2.03 / 2.50
4.88 / 6.00
25 + 25 + 25 + 50
2.08 / 2.56
2.08 / 2.56
2.08 / 2.56
4.16 / 5.12
22 + 22 + 25 + 71
1.68 / 2.07
1.68 / 2.07
1.91 / 2.36
5.43 / 6.69
22 + 22 + 35 + 35
1.97 / 2.39
1.97 / 2.39
3.13 / 3.81
3.13 / 3.81
22 + 22 + 35 + 50 22 + 22 + 35 + 60 22 + 22 + 35 + 71
1.79 / 2.20 1.69 / 2.09 1.57 / 1.94
1.79 / 2.20 1.69 / 2.09 1.57 / 1.94
2.85 / 3.50 2.69 / 3.32 2.50 / 3.08
4.07 / 5.00 4.62 / 5.70
25 + 25 + 25 + 60
1.63 / 2.02
1.63 / 2.02
3.72 / 4.58
1.54 / 1.89
1.54 / 1.89
3.51 / 4.29
22 + 22 + 60 + 60 22 + 22 + 60 + 71 22 + 25 + 25 + 25 22 + 25 + 25 + 35
1.44 / 1.76 1.45 / 1.77 1.36 / 1.58 2.20 / 270 2.08 / 2.51
1.44 / 1.76 1.45 / 1.77 1.36 / 1.58 2.50 / 3.07 2.36 / 2.85
3.27 / 4.00 3.95 / 4.83 3.70 / 4.32 2.50 / 3.07 2.36 / 2.85
1.83 / 2.26
5.20 / 6.42
25 + 25 + 35 + 35
2.17 / 2.63
2.17 / 2.63
3.03 / 3.68
3.03 / 3.68
25 + 25 + 35 + 50
1.96 / 2.43
1.96 / 2.43
2.75 / 3.40
3.93 / 4.85
5.06 / 6.25 1.84 / 2.28
1.84 / 2.28
2.58 / 3.19
4.43 / 5.46
3.72 / 4.58 1.73 / 2.12
1.73 / 2.12
2.42 / 2.96
4.92 / 6.01
4.21 / 5.14 1.78 / 2.20
1.78 / 2.20
3.57 / 4.40
3.57 / 4.40
4.65 / 5.68 3.95 / 4.83 4.38 / 5.11
25 + 25 + 50 + 60 25 + 25 + 50 + 71
2.50 / 3.07
25 + 25 + 60 + 60
3.30 / 3.99
25 + 35 + 35 + 35
22 + 25 + 25 + 50
1.88 / 2.29
2.13 / 2.60
2.13 / 2.60
4.26 / 5.20
22 + 25 + 25 + 60
1.77 / 2.17
2.01 / 2.46
2.01 / 2.46
4.82 / 5.91
22 + 25 + 25 + 71
1.65 / 2.03
1.87 / 2.31
1.87 / 2.31
5.31 / 6.55
22 + 25 + 35 + 35
1.94 / 2.35
2.20 / 2.67
3.08 / 3.74
3.08 / 3.74
22 + 25 + 35 + 50
1.77 / 2.17
2.01 / 2.46
2.81 / 3.45
4.02 / 4.92
22 + 25 + 35 + 60
1.66 / 2.05
1.88 / 2.32
2.64 / 3.25
4.52 / 5.58
25 + 35 + 35 + 50 25 + 35 + 35 + 60 25 + 35 + 35 + 71
22 + 25 + 35 + 71
1.54 / 1.90
1.75 / 2.16
2.45 / 3.02
4.97 / 6.13
22 + 25 + 50 + 50
1.60 / 1.98
1.82 / 2.24
3.64 / 4.49
3.64 / 4.49
1.72 / 2.10
3.44 / 4.20
4.13 / 5.04
22 + 25 + 50 + 71
1.41 / 1.73
1.61 / 1.96
3.21 / 3.93
4.56 / 5.58
22 + 25 + 60 + 60
1.42 / 1.74
1.62 / 1.98
3.88 / 4.74
3.88 / 4.74
22 + 25 + 60 + 71
1.33 / 1.56
1.52 / 1.77
3.64 / 4.25
4.31 / 5.03
1.59 / 1.85 2.02 / 2.48 1.84 / 2.28 1.74 / 2.13 1.63 / 1.99
25 + 35 + 50 + 60
1.59 / 1.85
35 + 35 + 35 + 35 1.51 / 1.85
1.58 / 1.84
1.69 / 2.06
25 + 50 + 50 + 50
22 + 25 + 50 + 60
1.69 / 2.06
25 + 35 + 50 + 50
25 + 35 + 60 + 60
150 / 1.75 1.54 / 1.80 2.68 / 3.30
1.69 / 2.06 1.58 / 1.84 1.59 / 1.85 2.83 / 3.47 2.58 / 3.19 2.44 / 2.98 2.28 / 2.78 2.36 / 2.89 2.22 / 2.59 2.10 / 2.45 3.09 / 3.60 2.68 / 3.30
3.38 / 4.13 3.16 / 3.68 3.81 / 4.45 2.83 / 3.47 2.58 / 3.19 2.44 / 2.98 2.28 / 2.78 3.38 / 4.13 3.18 / 3.71 3.60 / 4.20 3.09 / 3.60 2.68 / 3.30
4.05 / 4.95 4.48 / 5.23 3.81 / 4.45 2.83 / 3.47 3.69 / 4.55 4.18 / 5.11 4.62 / 5.65 3.38 / 4.13 3.81 / 4.45 3.60 / 4.20 3.09 / 3.60 2.68 / 3.30
35 + 35 + 35 + 50
2.44 / 2.98
2.44 / 2.98
2.44 / 2.98
3.48 / 4.26
35 + 35 + 35 + 60
2.29 / 2.80
2.29 / 2.80
2.29 / 2.80
3.93 / 4.80
35 + 35 + 35 + 71
22 + 35 + 35 + 35
1.83 / 2.22
2.89 / 3.53
2.89 / 3.53
2.89 / 3.53
35 + 35 + 50 + 50
22 + 35 + 35 + 50
1.66 / 2.05
2.64 / 3.25
2.64 / 3.25
3.77 / 4.65
35 + 35 + 50 + 60
Page 44
4.71 / 5.82
1.83 / 2.26
25 + 25 + 50 + 50 22 + 22 + 50 + 71
1.96 / 2.43
1.83 / 2.26
25 + 25 + 35 + 71 22 + 22 + 50 + 60
1.96 / 2.43
25 + 25 + 25 + 71
25 + 25 + 35 + 60 22 + 22 + 50 + 50
1.96 / 2.43
2.15 / 2.51 2.22 / 2.59 2.10 / 2.45
2.15 / 2.51 2.22 / 2.59 2.10 / 2.45
2.15 / 2.51 3.18 / 3.71 3.00 / 3.50
4.36 / 5.08 3.18 / 3.71 3.60 / 4.20
Indoor unit combination
Cooling / Heating Capacity (kW) Unit A
Unit B
Unit C
Unit D
Unit E
22 + 22 + 22 + 22 + 22
2.20 / 2.62
2.20 / 2.62
2.20 / 2.62
2.20 / 2.62
2.20 / 2.62
22 + 22 + 22 + 22 + 25
2.18 / 2.57
2.18 / 2.57
2.18 / 2.57
2.18 / 2.57
2.48 / 2.92
22 + 22 + 22 + 22 + 35
2.11 / 2.40
2.11 / 2.40
2.11 / 2.40
2.11 / 2.40
3.36 / 3.81
22 + 22 + 22 + 22 + 50
1.91 / 2.14
1.91 / 2.14
1.91 / 2.14
1.91 / 2.14
4.35 / 4.86
22 + 22 + 22 + 22 + 60
1.78 / 1.99
1.78 / 1.99
1.78 / 1.99
1.78 / 1.99
4.86 / 5.43
22 + 22 + 22 + 22 + 71
1.67 / 1.85
1.67 / 1.85
1.67 / 1.85
1.67 / 1.85
5.40 / 5.98
22 + 22 + 22 + 25 + 25
2.16 / 2.50
2.16 / 2.50
2.16 / 2.50
2.46 / 2.84
2.46 / 2.84
22 + 22 + 22 + 25 + 35
2.08 / 2.34
2.08 / 2.34
2.08 / 2.34
2.36 / 2.66
3.31 / 3.72
22 + 22 + 22 + 25 + 50
1.87 / 2.09
1.87 / 2.09
1.87 / 2.09
2.13 / 2.38
4.26 / 4.75
22 + 22 + 22 + 25 + 60
1.76 / 1.95
1.76 / 1.95
1.76 / 1.95
2.00 / 2.22
4.81 / 5.32
22 + 22 + 22 + 25 + 71
1.64 / 1.82
1.64 / 1.82
1.64 / 1.82
1.87 / 2.07
5.30 / 5.87
22 + 22 + 22 + 35 + 35
1.94 / 2.17
1.94 / 2.17
1.94 / 2.17
3.09 / 3.45
3.09 / 3.45
22 + 22 + 22 + 35 + 50
1.76 / 1.95
1.76 / 1.95
1.76 / 1.95
2.80 / 3.11
4.01 / 4.44
22 + 22 + 22 + 35 + 60
1.65 / 1.83
1.65 / 1.83
1.65 / 1.83
2.63 / 2.91
4.51 / 4.99
22 + 22 + 22 + 35 + 71
1.56 / 1.71
1.56 / 1.71
1.56 / 1.71
2.48 / 2.73
5.04 / 5.53
22 + 22 + 22 + 50 + 50
1.60 / 1.78
1.60 / 1.78
1.60 / 1.78
3.64 / 4.04
3.64 / 4.04
22 + 22 + 22 + 50 + 60
1.53 / 1.68
1.53 / 1.68
1.53 / 1.68
3.47 / 3.81
4.16 / 4.57
22 + 22 + 25 + 25 + 25
2.13 / 2.46
2.13 / 2.46
2.42 / 2.79
2.42 / 2.79
2.42 / 2.79
22 + 22 + 25 + 25 + 35
2.03 / 2.29
2.03 / 2.29
2.31 / 2.60
2.31 / 2.60
3.23 / 3.64
22 + 22 + 25 + 25 + 50
1.83 / 2.05
1.83 / 2.05
2.08 / 2.33
2.08 / 2.33
4.17 / 4.65
22 + 22 + 25 + 25 + 60
1.73 / 1.91
1.73 / 1.91
1.96 / 2.18
1.96 / 2.18
4.71 / 5.22
22 + 22 + 25 + 25 + 71
1.61 / 1.79
1.61 / 1.79
1.83 / 2.03
1.83 / 2.03
5.21 / 5.77
22 + 22 + 25 + 35 + 35
1.90 / 2.12
1.90 / 2.12
2.16 / 2.41
3.02 / 3.37
3.02 / 3.37
22 + 22 + 25 + 35 + 50
1.73 / 1.91
1.73 / 1.91
1.96 / 2.18
2.75 / 3.05
3.93 / 4.35
22 + 22 + 25 + 35 + 60
1.62 / 1.80
1.62 / 1.80
1.84 / 2.04
2.58 / 2.86
4.43 / 4.90
22 + 22 + 25 + 35 + 71
1.53 / 1.68
1.53 / 1.68
1.74 / 1.91
2.44 / 2.68
4.95 / 5.44
22 + 22 + 25 + 50 + 50
1.59 / 1.74
1.59 / 1.74
1.80 / 1.98
3.61 / 3.96
3.61 / 3.96
22 + 22 + 25 + 50 + 60
1.50 / 1.65
1.50 / 1.65
1.70 / 1.87
3.41 / 3.74
4.09 / 4.49
22 + 22 + 35 + 35 + 35
1.77 / 1.98
1.77 / 1.98
2.82 / 3.15
2.82 / 3.15
2.82 / 3.15
22 + 22 + 35 + 35 + 50
1.62 / 1.80
1.62 / 1.80
2.58 / 2.86
2.58 / 2.86
3.69 / 4.09
22 + 22 + 35 + 35 + 60
1.54 / 1.69
1.54 / 1.69
2.45 / 2.70
2.45 / 2.70
4.21 / 4.62
22 + 22 + 35 + 50 + 50
1.50 / 1.65
1.50 / 1.65
2.39 / 2.62
3.41 / 3.74
3.41 / 3.74
22 + 25 + 25 + 25 + 25
2.11 / 2.40
2.40 / 2.73
2.40 / 2.73
2.40 / 2.73
2.40 / 2.73
22 + 25 + 25 + 25 + 35
1.98 / 2.23
2.25 / 2.54
2.25 / 2.54
2.25 / 2.54
3.17 / 3.55
22 + 25 + 25 + 25 + 50
1.80 / 2.01
2.04 / 2.28
2.04 / 2.28
2.04 / 2.28
4.08 / 4.56
22 + 25 + 25 + 25 + 60
1.70 / 1.88
1.93 / 2.13
1.93 / 2.13
1.93 / 2.13
4.62 / 5.12
22 + 25 + 25 + 25 + 71
1.60 / 1.75
1.82 / 1.99
1.82 / 1.99
1.82 / 1.99
5.16 / 5.66
22 + 25 + 25 + 35 + 35
1.86 / 2.08
2.11 / 2.36
2.11 / 2.36
2.96 / 3.30
2.96 / 3.30
22 + 25 + 25 + 35 + 50
1.70 / 1.88
1.93 / 2.13
1.93 / 2.13
2.70 / 2.99
3.85 / 4.27
22 + 25 + 25 + 35 + 60
1.61 / 1.77
1.83 / 2.01
1.83 / 2.01
2.56 / 2.81
4.38 / 4.81
22 + 25 + 25 + 35 + 71
1.51 / 1.66
1.71 / 1.88
1.71 / 1.88
2.40 / 2.63
4.87 / 5.34
22 + 25 + 25 + 50 + 50
1.56 / 1.71
1.77 / 1.95
1.77 / 1.95
3.55 / 3.90
3.55 / 3.90
22 + 25 + 35 + 35 + 35
1.75 / 1.94
1.99 / 2.20
2.79 / 3.09
2.79 / 3.09
2.79 / 3.09
22 + 25 + 35 + 35 + 50
1.61 / 1.77
1.83 / 2.01
2.56 / 2.81
2.56 / 2.81
3.65 / 4.01
22 + 25 + 35 + 35 + 60
1.52 / 1.67
1.72 / 1.89
2.41 / 2.65
2.41 / 2.65
4.14 / 4.54
22 + 35 + 35 + 35 + 35
1.64 / 1.82
2.61 / 2.90
2.61 / 2.90
2.61 / 2.90
2.61 / 2.90
22 + 35 + 35 + 35 + 50
1.52 / 1.67
2.41 / 2.65
2.41 / 2.65
2.41 / 2.65
3.45 / 3.79
25 + 25 + 25 + 25 + 25
2.38 / 2.68
2.38 / 2.68
2.38 / 2.68
2.38 / 2.68
2.38 / 2.68
25 + 25 + 25 + 25 + 35
2.22 / 2.48
2.22 / 2.48
2.22 / 2.48
2.22 / 2.48
3.12 / 3.47
25 + 25 + 25 + 25 + 50
2.02 / 2.23
2.02 / 2.23
2.02 / 2.23
2.02 / 2.23
4.03 / 4.47
25 + 25 + 25 + 25 + 60
1.89 / 2.09
1.89 / 2.09
1.89 / 2.09
1.89 / 2.09
4.54 / 5.03
25 + 25 + 25 + 25 + 71
1.78 / 1.96
1.78 / 1.96
1.78 / 1.96
1.78 / 1.96
5.07 / 5.56
25 + 25 + 25 + 35 + 35
2.07 / 2.31
2.07 / 2.31
2.07 / 2.31
2.90 / 3.23
2.90 / 3.23
5 ROOMS
Page 45
Indoor unit combination
Cooling / Heating Capacity (kW)
MXZ-8B140VA 1 Outdoor Unit
Up to 8 Indoor Units
Unit A
Unit B
Unit C
Unit D
Unit E
25 + 25 + 25 + 35 + 50
1.89 / 2.09
1.89 / 2.09
1.89 / 2.09
2.65 / 2.93
3.78 / 4.19
25 + 25 + 25 + 35 + 60
1.79 / 1.97
1.79 / 1.97
1.79 / 1.97
2.51 / 2.76
4.31 / 4.73
25 + 25 + 25 + 50 + 50
1.74 / 1.91
1.74 / 1.91
1.74 / 1.91
3.49 / 3.83
3.49 / 3.83
25 + 25 + 35 + 35 + 35
1.95 / 2.16
1.95 / 2.16
2.73 / 3.03
2.73 / 3.03
2.73 / 3.03
1 ROOM
25 + 25 + 35 + 35 + 50
1.79 / 1.97
1.79 / 1.97
2.51 / 2.76
2.51 / 2.76
3.59 / 3.94
22
2.20 / 3.30
25 + 25 + 35 + 35 + 60
1.69 / 1.86
1.69 / 1.86
2.37 / 2.61
2.37 / 2.61
4.07 / 4.47
25
2.50 / 3.60
25 + 35 + 35 + 35 + 35
1.83 / 2.03
2.57 / 2.84
2.57 / 2.84
2.57 / 2.84
Indoor unit combination
Cooling / Heating Capacity (kW) Unit A
35
2.57 / 2.84
2.37 / 2.61
2.37 / 2.61
2.37 / 2.61
3.39 / 3.72
50
35 + 35 + 35 + 35 + 35
2.44 / 2.68
2.44 / 2.68
2.44 / 2.68
2.44 / 2.68
2.44 / 2.68
60
6.00 / 7.90
71
7.10 / 8.60
100
10.00 / 11.20
22 + 22 + 22 + 22 + 22 + 25 22 + 22 + 22 + 22 + 22 + 35 22 + 22 + 22 + 22 + 22 + 50 22 + 22 + 22 + 22 + 22 + 60
2.00 / 2.33 1.96 / 2.28 1.82 / 2.12 1.65 / 1.93 1.55 / 1.81
2.00 / 2.33 1.96 / 2.28 1.82 / 2.12 1.65 / 1.93 1.55 / 1.81
2.00 / 2.33 1.96 / 2.28 1.82 / 2.12 1.65 / 1.93 1.55 / 1.81
2.00 / 2.33 1.96 / 2.28 1.82 / 2.12 1.65 / 1.93 1.55 / 1.81
2.00 / 2.33 1.96 / 2.28 1.82 / 2.12 1.65 / 1.93 1.55 / 1.81
2.00 / 2.33 2.22 / 2.59 2.90 / 3.38 3.75 / 4.38 4.24 / 4.94
22 + 22 + 22 + 22 + 25 + 25
1.91 / 2.23
1.91 / 2.23
1.91 / 2.23
1.91 / 2.23
2.17 / 2.54
2.17 / 2.54
22 + 22 + 22 + 22 + 25 + 35
1.78 / 2.08
1.78 / 2.08
1.78 / 2.08
1.78 / 2.08
2.03 / 2.36
2.84 / 3.31
22 + 22 + 22 + 22 + 25 + 50
1.62 / 1.89
1.62 / 1.89
1.62 / 1.89
1.62 / 1.89
1.84 / 2.15
3.68 / 4.29
22 + 22 + 22 + 22 + 25 + 60
1.53 / 1.78
1.53 / 1.78
1.53 / 1.78
1.53 / 1.78
1.73 / 2.02
4.16 / 4.86
22 + 22 + 22 + 22 + 35 + 35
1.67 / 1.95
1.67 / 1.95
1.67 / 1.95
1.67 / 1.95
2.66 / 3.10
2.66 / 3.10
22 + 22 + 22 + 22 + 35 + 50 22 + 22 + 22 + 25 + 25 + 25 22 + 22 + 22 + 25 + 25 + 35
1.53 / 1.78 1.87 / 2.18 1.75 / 2.04
1.53 / 1.78 1.87 / 2.18 1.75 / 2.04
1.53 / 1.78 1.87 / 2.18 1.75 / 2.04
1.53 / 1.78 2.13 / 2.48 1.99 / 2.32
2.43 / 2.83 2.13 / 2.48 1.99 / 2.32
3.47 / 4.05 2.13 / 2.48 2.78 / 3.25
22 + 22 + 22 + 25 + 25 + 50
1.59 / 1.86
1.59 / 1.86
1.59 / 1.86
1.81 / 2.11
1.81 / 2.11
3.61 / 4.22
22 + 22 + 22 + 25 + 25 + 60
1.50 / 1.75
1.50 / 1.75
1.50 / 1.75
1.70 / 1.99
1.70 / 1.99
4.09 / 4.77
22 + 22 + 22 + 25 + 35 + 35
1.64 / 1.91
1.64 / 1.91
1.64 / 1.91
1.86 / 2.17
2.61 / 3.04
2.61 / 3.04
22 + 22 + 22 + 25 + 35 + 50
1.50 / 1.75
1.50 / 1.75
1.50 / 1.75
1.70 / 1.99
2.39 / 2.78
3.41 / 3.98
22 + 22 + 22 + 35 + 35 + 35
1.54 / 1.80
1.54 / 1.80
1.54 / 1.80
2.46 / 2.87
2.46 / 2.87
2.46 / 2.87
22 + 22 + 25 + 25 + 25 + 25
1.83 / 2.14
1.83 / 2.14
2.08 / 2.43
2.08 / 2.43
2.08 / 2.43
2.08 / 2.43
22 + 22 + 25 + 25 + 25 + 35
1.71 / 2.00
1.71 / 2.00
1.95 / 2.27
1.95 / 2.27
1.95 / 2.27
2.73 / 3.18
22 + 22 + 25 + 25 + 25 + 50
1.56 / 1.82
1.56 / 1.82
1.78 / 2.07
1.78 / 2.07
1.78 / 2.07
3.55 / 4.14
22 + 22 + 25 + 25 + 25 + 60 22 + 22 + 25 + 25 + 35 + 35 22 + 22 + 25 + 25 + 35 + 50 22 + 22 + 25 + 35 + 35 + 35 22 + 25 + 25 + 25 + 25 + 25
1.47 / 1.72 1.61 / 1.88 1.47 / 1.72 1.52 / 1.77 1.80 / 2.10
1.47 / 1.72 1.61 / 1.88 1.47 / 1.72 1.52 / 1.77 2.04 / 2.38
1.68 / 1.96 1.83 / 2.13 1.68 / 1.96 1.72 / 2.01 2.04 / 2.38
1.68 / 1.96 1.83 / 2.13 1.68 / 1.96 2.41 / 2.82 2.04 / 2.38
1.68 / 1.96 2.56 / 2.99 2.35 / 2.74 2.41 / 2.82 2.04 / 2.38
4.02 / 4.69 2.56 / 2.99 3.35 / 3.91 2.41 / 2.82 2.04 / 2.38
22 + 25 + 25 + 25 + 25 + 35
1.68 / 1.96
1.91 / 2.23
1.91 / 2.23
1.91 / 2.23
1.91 / 2.23
2.68 / 3.12
22 + 25 + 25 + 25 + 25 + 50
1.53 / 1.79
1.74 / 2.03
1.74 / 2.03
1.74 / 2.03
1.74 / 2.03
3.49 / 4.07
22 + 25 + 25 + 25 + 35 + 35
1.58 / 1.84
1.80 / 2.10
1.80 / 2.10
1.80 / 2.10
2.51 / 2.93
2.51 / 2.93
22 + 25 + 25 + 35 + 35 + 35
1.49 / 1.74
1.69 / 1.98
1.69 / 1.98
2.37 / 2.77
2.37 / 2.77
2.37 / 2.77
25 + 25 + 25 + 25 + 25 + 25
2.00 / 2.33
2.00 / 2.33
2.00 / 2.33
2.00 / 2.33
2.00 / 2.33
2.00 / 2.33
25 + 25 + 25 + 25 + 25 + 35
1.88 / 2.19
1.88 / 2.19
1.88 / 2.19
1.88 / 2.19
1.88 / 2.19
2.63 / 3.06
25 + 25 + 25 + 25 + 25 + 50
1.71 / 2.00
1.71 / 2.00
1.71 / 2.00
1.71 / 2.00
1.71 / 2.00
3.43 / 4.00
25 + 25 + 25 + 25 + 35 + 35 25 + 25 + 25 + 35 + 35 + 35
Page 46
1.76 / 2.06 1.67 / 1.94
1.76 / 2.06 1.67 / 1.94
1.76 / 2.06 1.67 / 1.94
1.76 / 2.06 2.33 / 2.72
2.47 / 2.88 2.33 / 2.72
2.47 / 2.88 2.33 / 2.72
Unit C
3.50 / 4.00
1.69 / 1.86
6 ROOMS
Unit B
5.00 / 7.20
2 ROOMS
Unit D
Cooling / Heating Capacity (kW) Unit A
Unit B
22 + 25 + 50
2.20 / 2.52
2.50 / 2.86
5.00 / 5.72
22 + 25 + 60
2.20 / 2.51
2.50 / 2.85
6.00 / 6.84
22 + 25 + 71
2.20 / 2.52
2.50 / 2.86
7.10 / 8.12
22 + 25 + 100
2.10 / 2.39
2.38 / 2.72
9.52 / 10.88
22 + 35 + 35
2.20 / 2.51
3.50 / 3.99
3.50 / 3.99
22 + 35 + 50
2.20 / 2.51
3.50 / 3.99
5.00 / 5.70
22 + 35 + 60
2.20 / 2.52
3.50 / 4.01
6.00 / 6.87
22 + 35 + 71
2.20 / 2.51
3.50 / 3.99
7.10 / 8.10
22 + 35 + 100
1.96 / 2.24
3.12 / 3.57
8.92 / 10.19
22 + 50 + 50
2.20 / 2.51
5.00 / 5.70
5.00 / 5.70
22 + 50 + 60
2.20 / 2.52
5.00 / 5.72
6.00 / 6.86
22 + 50 + 71
2.15 / 2.46
4.90 / 5.59
6.95 / 7.94
22 + 50 + 100
1.79 / 2.05
4.07 / 4.65
8.14 / 9.30
22 + 60 + 60
2.17 / 2.48
5.92 / 6.76
5.92 / 6.76
Unit F
25 + 35 + 35 + 35 + 50
22 + 22 + 22 + 22 + 22 + 22
Indoor unit combination
Unit C
22 + 22
2.20 / 2.50
2.20 / 2.50
22 + 60 + 71
2.01 / 2.30
5.49 / 6.27
6.50 / 7.42
22 + 25
2.20 / 2.53
2.50 / 2.87
22 + 60 + 100
1.69 / 1.93
4.62 / 5.27
7.69 / 8.79
22 + 35
2.20 / 2.51
3.50 / 3.99
22 + 71 + 71
1.88 / 2.15
6.06 / 6.93
6.06 / 6.93
22 + 50
2.20 / 2.51
5.00 / 5.69
25 + 25 + 25
2.50 / 2.87
2.50 / 2.87
2.50 / 2.87
22 + 60
2.20 / 2.52
6.00 / 6.88
25 + 25 + 35
2.50 / 2.85
2.50 / 2.85
3.50 / 3.99
25 + 25 + 50
2.50 / 2.85
2.50 / 2.85
5.00 / 5.70
25 + 25 + 60
2.50 / 2.86
2.50 / 2.86
6.00 / 6.87
25 + 25 + 71
2.50 / 2.85
2.50 / 2.85
7.10 / 8.10
25 + 25 + 100
2.33 / 2.67
2.33 / 2.67
9.33 / 10.67
22 + 71 22 + 100
2.20 / 2.51
7.10 / 8.09
2.20 / 2.51 10.00 / 11.39
25 + 25
2.50 / 2.85
2.50 / 2.85
25 + 35
2.50 / 2.88
3.50 / 4.03
25 + 35 + 35
2.50 / 2.87
3.50 / 4.02
3.50 / 4.02
25 + 50
2.50 / 2.87
5.00 / 5.73
25 + 35 + 50
2.50 / 2.86
3.50 / 4.01
5.00 / 5.73
25 + 60
2.50 / 2.85
6.00 / 6.85
25 + 35 + 60
2.50 / 2.85
3.50 / 4.00
6.00 / 6.85
25 + 71
2.50 / 2.86
7.10 / 8.14
25 + 35 + 71
2.50 / 2.86
3.50 / 4.01
7.10 / 8.13
25 + 100
2.50 / 2.86 10.00 / 11.44
25 + 35 + 100
2.19 / 2.50
3.06 / 3.50
8.75 / 10.00
35 + 35
3.50 / 4.00
3.50 / 4.00
25 + 50 + 50
2.50 / 2.86
5.00 / 5.72
5.00 / 5.72
5.00 / 5.71
25 + 50 + 60
2.50 / 2.85
5.00 / 5.70
6.00 / 6.84
6.00 / 6.88
25 + 50 + 71
2.40 / 2.74
4.79 / 5.48
6.81 / 7.78
25 + 50 + 100
2.00 / 2.29
4.00 / 4.57
8.00 / 9.14
25 + 60 + 60
2.41 / 2.76
5.79 / 6.62
5.79 / 6.62
25 + 60 + 71
2.24 / 2.56
5.38 / 6.15
6.37 / 7.28
25 + 60 + 100
1.89 / 2.16
4.54 / 5.19
7.57 / 8.65
25 + 71 + 71
2.10 / 2.40
5.95 / 6.80
5.95 / 6.80
35 + 35 + 35
3.50 / 4.00
3.50 / 4.00
3.50 / 4.00
35 + 50 35 + 60 35 + 71 35 + 100 50 + 50
3.50 / 3.99 3.50 / 4.02 3.50 / 4.00
7.10 / 8.10
3.50 / 3.99 10.00 / 11.41 5.00 / 5.70
5.00 / 5.70
50 + 60
5.00 / 5.73
6.00 / 6.87
50 + 71
5.00 / 5.70
7.10 / 8.10
60 + 60
6.00 / 6.85
6.00 / 6.85
35 + 35 + 50
3.50 / 4.00
3.50 / 4.00
5.00 / 5.71
60 + 71
6.00 / 6.87
7.10 / 8.13
35 + 35 + 60
3.50 / 4.01
3.50 / 4.01
6.00 / 6.88
60 + 100
5.25 / 6.00
8.75 / 10.00
35 + 35 + 71
3.48 / 3.97
3.48 / 3.97
7.05 / 8.06
71 + 71
7.00 / 8.00
7.00 / 8.00
35 + 35 + 100
2.88 / 3.29
2.88 / 3.29
8.24 / 9.41
8.19 / 9.36
35 + 50 + 50
3.50 / 3.99
5.00 / 5.70
5.00 / 5.70
35 + 50 + 60
3.38 / 3.86
4.83 / 5.52
5.79 / 6.62
35 + 50 + 71
3.14 / 3.59
4.49 / 5.13
6.37 / 7.28
35 + 50 + 100
2.65 / 3.03
3.78 / 4.32
7.57 / 8.65
35 + 60 + 60
3.16 / 3.61
5.42 / 6.19
5.42 / 6.19
35 + 60 + 71
2.95 / 3.37
5.06 / 5.78
5.99 / 6.84
35 + 71 + 71
2.77 / 3.16
5.62 / 6.42
5.62 / 6.42
50 + 50 + 50
4.67 / 5.33
4.67 / 5.33
4.67 / 5.33
50 + 50 + 60
4.38 / 5.00
4.38 / 5.00
5.25 / 6.00
71 + 100
5.81 / 6.64
足
3 ROOMS 22 + 22 + 22 22 + 22 + 25 22 + 22 + 35
2.20 / 2.50 2.20 / 2.52
2.20 / 2.50 2.20 / 2.52
2.20 / 2.50 2.50 / 2.86
2.20 / 2.51
2.20 / 2.51
3.50 / 3.99
22 + 22 + 50
2.20 / 2.50
2.20 / 2.50
5.00 / 5.69
22 + 22 + 60
2.20 / 2.52
2.20 / 2.52
6.00 / 6.87
22 + 22 + 71
2.20 / 2.51
2.20 / 2.51
7.10 / 8.09
50 + 50 + 71
4.09 / 4.68
4.09 / 4.68
5.81 / 6.64
22 + 22 + 100
2.14 / 2.44
2.14 / 2.44
9.72 / 11.11
50 + 60 + 60
4.12 / 4.71
4.94 / 5.65
4.94 / 5.65
22 + 25 + 25
2.20 / 2.51
2.50 / 2.85
2.50 / 2.85
50 + 60 + 71
3.87 / 4.42
4.64 / 5.30
5.49 / 6.28
22 + 25 + 35
2.20 / 2.52
2.50 / 2.87
3.50 / 4.01
60 + 60 + 60
4.67 / 5.33
4.67 / 5.33
4.67 / 5.33
Unit D
Page 47
Indoor unit combination
Cooling / Heating Capacity (kW) Unit A
Unit B
Unit C
Indoor unit combination
Unit D
4 ROOMS
Cooling / Heating Capacity (kW) Unit A
Unit B
Unit C
Unit D
22 + 35 + 35 + 60
2.03 / 2.32
3.22 / 3.68
3.22 / 3.68
5.53 / 6.32
Indoor unit combination
Cooling / Heating Capacity (kW) Unit A
Unit B
Unit C
Unit D
Unit E
22 + 22 + 22 + 22 + 22
2.20 / 2.52
2.20 / 2.52
2.20 / 2.52
2.20 / 2.52
2.20 / 2.52
22 + 22 + 22 + 22 + 25
2.20 / 2.51
2.20 / 2.51
2.20 / 2.51
2.20 / 2.51
2.50 / 2.85
22 + 22 + 22 + 22 + 35
2.20 / 2.52
2.20 / 2.52
2.20 / 2.52
2.20 / 2.52
3.50 / 4.01
2.20 / 2.53
2.20 / 2.53
2.20 / 2.53
2.20 / 2.53
22 + 35 + 35 + 71
1.89 / 2.16
3.01 / 3.44
3.01 / 3.44
6.10 / 6.97
22 + 22 + 22 + 25
2.20 / 2.51
2.20 / 2.51
2.20 / 2.51
2.50 / 2.86
22 + 35 + 50 + 50
1.96 / 2.24
3.12 / 3.57
4.46 / 5.10
4.46 / 5.10
22 + 22 + 22 + 35
2.20 / 2.50
2.20 / 2.50
2.20 / 2.50
3.50 / 3.99
22 + 35 + 50 + 60
1.84 / 2.11
2.93 / 3.35
4.19 / 4.79
5.03 / 5.75
22 + 22 + 22 + 22 + 50
2.20 / 2.52
2.20 / 2.52
2.20 / 2.52
2.20 / 2.52
5.00 / 5.72
22 + 22 + 22 + 50
2.20 / 2.52
2.20 / 2.52
2.20 / 2.52
5.00 / 5.73
22 + 35 + 50 + 71
5.58 / 6.38
22 + 22 + 22 + 22 + 60
2.08 / 2.38
2.08 / 2.38
2.08 / 2.38
2.08 / 2.38
5.68 / 6.49
22 + 22 + 22 + 22 + 71
1.94 / 2.21
1.94 / 2.21
1.94 / 2.21
1.94 / 2.21
6.25 / 7.14
22 + 22 + 22 + 25 + 25
2.20 / 2.52
2.20 / 2.52
2.20 / 2.52
2.50 / 2.87
2.50 / 2.87
22 + 22 + 22 + 25 + 35
2.20 / 2.51
2.20 / 2.51
2.20 / 2.51
2.50 / 2.86
3.50 / 4.00
2.75 / 3.15
3.93 / 4.49
22 + 22 + 22 + 60
2.20 / 2.51
2.20 / 2.51
2.20 / 2.51
6.00 / 6.86
22 + 35 + 60 + 60
1.74 / 1.99
2.77 / 3.16
4.75 / 5.42
4.75 / 5.42
22 + 22 + 22 + 71
2.20 / 2.52
2.20 / 2.52
2.20 / 2.52
7.10 / 8.14
22 + 50 + 50 + 50
1.79 / 2.05
4.07 / 4.65
4.07 / 4.65
4.07 / 4.65
22 + 22 + 22 + 100 1.86 / 2.12
1.86 / 2.12
1.86 / 2.12
8.43 / 9.64
22 + 50 + 50 + 60
1.69 / 1.93
3.85 / 4.40
3.85 / 4.40
4.62 / 5.27
22 + 22 + 22 + 25 + 50
2.18 / 2.50
2.18 / 2.50
2.18 / 2.50
2.48 / 2.84
4.96 / 5.67
2.20 / 2.50
2.20 / 2.50
2.50 / 2.85
2.50 / 2.85
25 + 25 + 25 + 25
2.50 / 2.85
2.50 / 2.85
2.50 / 2.85
2.50 / 2.85
22 + 22 + 22 + 25 + 60
2.04 / 2.33
2.04 / 2.33
2.04 / 2.33
2.32 / 2.65
5.56 / 6.36
22 + 22 + 22 + 25 + 71
1.90 / 2.17
1.90 / 2.17
1.90 / 2.17
2.16 / 2.47
6.14 / 7.01
22 + 22 + 22 + 35 + 35
2.20 / 2.51
2.20 / 2.51
2.20 / 2.51
3.50 / 3.99
3.50 / 3.99
22 + 22 + 25 + 25 22 + 22 + 25 + 35
2.20 / 2.52
2.20 / 2.52
2.50 / 2.86
3.50 / 4.00
22 + 22 + 25 + 50
2.20 / 2.51
2.20 / 2.51
2.50 / 2.86
5.00 / 5.71
22 + 22 + 25 + 60
2.20 / 2.51
2.20 / 2.51
2.50 / 2.85
6.00 / 6.84
22 + 22 + 25 + 71
2.20 / 2.51
2.20 / 2.51
2.50 / 2.86
7.10 / 8.11
22 + 22 + 25 + 100 1.82 / 2.08
1.82 / 2.08
2.07 / 2.37
8.28 / 9.47
22 + 22 + 35 + 35
2.20 / 2.51
2.20 / 2.51
3.50 / 3.99
3.50 / 3.99
22 + 22 + 35 + 50
2.20 / 2.51
2.20 / 2.51
3.50 / 3.99
5.00 / 5.70
22 + 22 + 35 + 60
2.20 / 2.52
2.20 / 2.52
3.50 / 4.00
6.00 / 6.86
22 + 22 + 35 + 71
2.05 / 2.35
2.05 / 2.35
3.27 / 3.73
6.63 / 7.57
22 + 22 + 35 + 100 1.72 / 1.97
1.72 / 1.97
2.74 / 3.13
7.82 / 8.94
22 + 22 + 50 + 50
2.14 / 2.44
2.14 / 2.44
4.86 / 5.56
4.86 / 5.56
22 + 22 + 50 + 60
2.00 / 2.29
2.00 / 2.29
4.55 / 5.19
5.45 / 6.23
22 + 22 + 50 + 71
1.87 / 2.13
1.87 / 2.13
4.24 / 4.85
6.02 / 6.88
22 + 22 + 60 + 60
1.88 / 2.15
1.88 / 2.15
5.12 / 5.85
5.12 / 5.85
22 + 22 + 60 + 71
25 + 25 + 25 + 35
1.76 / 2.01
4.80 / 5.49
2.20 / 2.52
2.50 / 2.86
2.50 / 2.86
2.50 / 2.86
22 + 25 + 25 + 35
2.20 / 2.51
2.50 / 2.85
2.50 / 2.85
3.50 / 3.99
22 + 25 + 25 + 50
2.20 / 2.51
2.50 / 2.85
2.50 / 2.85
5.00 / 5.70
22 + 25 + 25 + 60
2.20 / 2.52
2.50 / 2.86
2.50 / 2.86
6.00 / 6.86
2.50 / 2.86
2.50 / 2.86
5.00 / 5.72
22 + 22 + 22 + 35 + 50
2.04 / 2.33
2.04 / 2.33
2.04 / 2.33
3.25 / 3.71
4.64 / 5.30
25 + 25 + 25 + 60
2.50 / 2.85
2.50 / 2.85
2.50 / 2.85
6.00 / 6.84
22 + 22 + 22 + 35 + 60
1.91 / 2.19
1.91 / 2.19
1.91 / 2.19
3.04 / 3.48
5.22 / 5.96
25 + 25 + 25 + 71
2.40 / 2.74
2.40 / 2.74
2.40 / 2.74
6.81 / 7.78
22 + 22 + 22 + 35 + 71
1.79 / 2.05
1.79 / 2.05
1.79 / 2.05
2.85 / 3.26
5.78 / 6.60
8.00 / 9.14
22 + 22 + 22 + 50 + 50
1.86 / 2.12
1.86 / 2.12
1.86 / 2.12
4.22 / 4.82
4.22 / 4.82
22 + 22 + 22 + 50 + 60
1.75 / 2.00
1.75 / 2.00
1.75 / 2.00
3.98 / 4.55
4.77 / 5.45
2.20 / 2.51
2.50 / 2.86
2.50 / 2.86
2.50 / 2.86
25 + 25 + 25 + 100 2.00 / 2.29
2.45 / 2.80
6.95 / 7.94
22 + 25 + 25 + 100 1.79 / 2.05
2.03 / 2.33
2.03 / 2.33
8.14 / 9.30
22 + 25 + 35 + 35
2.20 / 2.52
2.50 / 2.86
3.50 / 4.01
3.50 / 4.01
22 + 25 + 35 + 50
2.20 / 2.52
2.50 / 2.86
3.50 / 4.00
5.00 / 5.72
22 + 25 + 35 + 60 22 + 25 + 35 + 71
2.17 / 2.48 2.01 / 2.30
2.46 / 2.82 2.29 / 2.61
3.45 / 3.94 3.20 / 3.66
5.92 / 6.76 6.50 / 7.42
22 + 25 + 35 + 100 1.69 / 1.93
1.92 / 2.20
2.69 / 3.08
7.69 / 8.79
22 + 25 + 50 + 50
2.10 / 2.39
2.38 / 2.72
4.76 / 5.44
4.76 / 5.44
22 + 25 + 50 + 60
1.96 / 2.24
2.23 / 2.55
4.46 / 5.10
5.35 / 6.11
22 + 25 + 50 + 71
1.83 / 2.10
2.08 / 2.38
4.17 / 4.76
2.00 / 2.29
2.00 / 2.29
25 + 25 + 35 + 35
2.50 / 2.85
2.50 / 2.85
3.50 / 4.00
3.50 / 4.00
22 + 22 + 25 + 25 + 25
2.20 / 2.51
25 + 25 + 35 + 50
2.50 / 2.85
2.50 / 2.85
3.50 / 3.99
5.00 / 5.70
22 + 22 + 25 + 25 + 35
2.20 / 2.51
2.20 / 2.51
2.50 / 2.85
2.50 / 2.85
3.50 / 3.99
25 + 25 + 35 + 60
2.41 / 2.76
2.41 / 2.76
3.38 / 3.86
5.79 / 6.62
22 + 22 + 25 + 25 + 50
2.14 / 2.44
2.14 / 2.44
2.43 / 2.78
2.43 / 2.78
4.86 / 5.56
6.37 / 7.28
22 + 22 + 25 + 25 + 60
2.00 / 2.29
2.00 / 2.29
2.27 / 2.60
2.27 / 2.60
5.45 / 6.23
22 + 22 + 25 + 25 + 71
1.87 / 2.13
1.87 / 2.13
2.12 / 2.42
2.12 / 2.42
6.02 / 6.88
2.20 / 2.52
2.50 / 2.86
3.50 / 4.00
3.50 / 4.00
25 + 25 + 35 + 71
2.24 / 2.56
2.24 / 2.56
3.14 / 3.59
25 + 25 + 35 + 100 1.89 / 2.16
1.89 / 2.16
2.65 / 3.03
7.57 / 8.65
22 + 22 + 25 + 35 + 35
2.20 / 2.52
25 + 25 + 50 + 50
2.33 / 2.67
2.33 / 2.67
4.67 / 5.33
4.67 / 5.33
22 + 22 + 25 + 35 + 50
2.00 / 2.29
2.00 / 2.29
2.27 / 2.60
3.18 / 3.64
4.55 / 5.19
25 + 25 + 50 + 60
2.19 / 2.50
2.19 / 2.50
4.38 / 5.00
5.25 / 6.00
22 + 22 + 25 + 35 + 60
1.88 / 2.15
1.88 / 2.15
2.13 / 2.44
2.99 / 3.41
5.12 / 5.85
5.81 / 6.64
22 + 22 + 25 + 35 + 71
1.76 / 2.01
1.76 / 2.01
2.00 / 2.29
2.80 / 3.20
5.68 / 6.49
22 + 22 + 25 + 50 + 50
1.82 / 2.08
1.82 / 2.08
2.07 / 2.37
4.14 / 4.73
4.14 / 4.73
1.72 / 1.97
1.96 / 2.23
3.91 / 4.47
4.69 / 5.36
2.05 / 2.34
2.05 / 2.34
4.09 / 4.68
25 + 25 + 60 + 60
2.06 / 2.35
2.06 / 2.35
4.94 / 5.65
4.94 / 5.65
22 + 22 + 25 + 50 + 60
1.72 / 1.97
25 + 25 + 60 + 71
1.93 / 2.21
1.93 / 2.21
4.64 / 5.30
5.49 / 6.28
22 + 22 + 35 + 35 + 35
2.07 / 2.36
2.07 / 2.36
3.29 / 3.76
3.29 / 3.76
3.29 / 3.76
25 + 35 + 35 + 35
2.50 / 2.87
3.50 / 4.01
3.50 / 4.01
3.50 / 4.01
22 + 22 + 35 + 35 + 50
1.88 / 2.15
1.88 / 2.15
2.99 / 3.41
2.99 / 3.41
4.27 / 4.88
4.83 / 5.52
22 + 22 + 35 + 35 + 60
1.77 / 2.02
1.77 / 2.02
2.82 / 3.22
2.82 / 3.22
4.83 / 5.52
22 + 22 + 35 + 35 + 71
1.66 / 1.90
1.66 / 1.90
2.65 / 3.03
2.65 / 3.03
5.37 / 6.14
22 + 22 + 35 + 50 + 50
1.72 / 1.97
1.72 / 1.97
2.74 / 3.13
3.91 / 4.47
3.91 / 4.47
22 + 25 + 25 + 25 + 25
2.20 / 2.51
2.50 / 2.85
2.50 / 2.85
2.50 / 2.85
2.50 / 2.85
2.50 / 2.86
2.50 / 2.86
2.50 / 2.86
3.50 / 4.00
25 + 35 + 35 + 60 2.45 / 2.80
3.50 / 4.01
2.50 / 2.86
25 + 35 + 35 + 50
2.15 / 2.46
2.50 / 2.86
5.68 / 6.49
22 + 25 + 25 + 25
22 + 25 + 25 + 71
2.50 / 2.86
25 + 25 + 25 + 50
25 + 25 + 50 + 71 1.76 / 2.01
2.50 / 2.86
5.92 / 6.76
25 + 35 + 35 + 71
2.41 / 2.76
3.38 / 3.86
3.38 / 3.86
2.26 / 2.58
3.16 / 3.61
3.16 / 3.61
5.42 / 6.19
2.11 / 2.41
2.95 / 3.37
2.95 / 3.37
5.99 / 6.84
25 + 35 + 50 + 50
2.19 / 2.50
3.06 / 3.50
4.38 / 5.00
4.38 / 5.00
22 + 25 + 25 + 25 + 35
2.20 / 2.52
25 + 35 + 50 + 60
2.06 / 2.35
2.88 / 3.29
4.12 / 4.71
4.94 / 5.65
22 + 25 + 25 + 25 + 50
2.10 / 2.39
2.38 / 2.72
2.38 / 2.72
2.38 / 2.72
4.76 / 5.44
22 + 25 + 25 + 25 + 60
1.96 / 2.24
2.23 / 2.55
2.23 / 2.55
2.23 / 2.55
5.35 / 6.11
22 + 25 + 25 + 25 + 71
1.83 / 2.10
2.08 / 2.38
2.08 / 2.38
2.08 / 2.38
5.92 / 6.76
22 + 25 + 25 + 35 + 35
2.17 / 2.48
2.46 / 2.82
2.46 / 2.82
3.45 / 3.94
3.45 / 3.94
22 + 25 + 25 + 35 + 50
1.96 / 2.24
2.23 / 2.55
2.23 / 2.55
3.12 / 3.57
4.46 / 5.10
22 + 25 + 25 + 35 + 60
1.84 / 2.11
2.10 / 2.40
2.10 / 2.40
2.93 / 3.35
5.03 / 5.75
22 + 25 + 25 + 35 + 71
1.73 / 1.98
1.97 / 2.25
1.97 / 2.25
2.75 / 3.15
5.58 / 6.38
22 + 25 + 25 + 50 + 50
1.79 / 2.05
2.03 / 2.33
2.03 / 2.33
4.07 / 4.65
4.07 / 4.65
25 + 35 + 50 + 71 25 + 35 + 60 + 60 25 + 50 + 50 + 50
1.93 / 2.21
2.71 / 3.09
3.87 / 4.42
5.49 / 6.28
1.94 / 2.22
2.72 / 3.11
4.67 / 5.33
4.67 / 5.33
2.00 / 2.29
4.00 / 4.57
4.00 / 4.57
4.00 / 4.57
25 + 50 + 50 + 60
1.89 / 2.16
3.78 / 4.32
3.78 / 4.32
4.54 / 5.19
35 + 35 + 35 + 35
3.50 / 4.00
3.50 / 4.00
3.50 / 4.00
3.50 / 4.00
35 + 35 + 35 + 50
3.16 / 3.61
3.16 / 3.61
3.16 / 3.61
4.52 / 5.16
22 + 25 + 25 + 50 + 60
1.69 / 1.93
1.92 / 2.20
1.92 / 2.20
3.85 / 4.40
4.62 / 5.27
35 + 35 + 35 + 60
2.97 / 3.39
2.97 / 3.39
2.97 / 3.39
5.09 / 5.82
22 + 25 + 35 + 35 + 35
2.03 / 2.32
2.30 / 2.63
3.22 / 3.68
3.22 / 3.68
3.22 / 3.68
22 + 25 + 35 + 35 + 50
1.84 / 2.11
2.10 / 2.40
2.93 / 3.35
2.93 / 3.35
4.19 / 4.79
22 + 25 + 35 + 35 + 60
1.74 / 1.99
1.98 / 2.26
2.77 / 3.16
2.77 / 3.16
4.75 / 5.42
22 + 25 + 35 + 50 + 50
1.69 / 1.93
1.92 / 2.20
2.69 / 3.08
3.85 / 4.40
3.85 / 4.40
22 + 35 + 35 + 35 + 35
1.90 / 2.17
3.02 / 3.46
3.02 / 3.46
3.02 / 3.46
3.02 / 3.46
22 + 35 + 35 + 35 + 50
1.74 / 1.99
2.77 / 3.16
2.77 / 3.16
2.77 / 3.16
3.95 / 4.52
22 + 25 + 60 + 60
1.84 / 2.10
2.10 / 2.40
5.03 / 5.75
5.03 / 5.75
35 + 35 + 35 + 71
22 + 25 + 60 + 71
1.73 / 1.98
1.97 / 2.25
4.72 / 5.39
5.58 / 6.38
35 + 35 + 50 + 50
2.88 / 3.29
2.88 / 3.29
4.12 / 4.71
4.12 / 4.71
22 + 35 + 35 + 35
2.20 / 2.51
3.50 / 4.00
3.50 / 4.00
3.50 / 4.00
35 + 35 + 50 + 60
2.72 / 3.11
2.72 / 3.11
3.89 / 4.44
4.67 / 5.33
4.93 / 5.63
35 + 50 + 50 + 50
2.65 / 3.03
3.78 / 4.32
3.78 / 4.32
3.78 / 4.32
22 + 35 + 35 + 50
Page 48
2.17 / 2.48
3.45 / 3.94
3.45 / 3.94
2.78 / 3.18
2.78 / 3.18
2.78 / 3.18
5.65 / 6.45
Unit G
Unit H
5 ROOMS
22 + 22 + 22 + 22
1.73 / 1.98
Unit F
Page 49
Indoor unit combination
Indoor unit combination
Cooling / Heating Capacity (kW)
Cooling / Heating Capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit E
Unit A
Unit B
Unit C
Unit D
Unit E
Unit F
25 + 25 + 25 + 25 + 25
2.50 / 2.86
2.50 / 2.86
2.50 / 2.86
2.50 / 2.86
2.50 / 2.86
22 + 25 + 25 + 25 + 25 + 35
1.96 / 2.24
2.23 / 2.55
2.23 / 2.55
2.23 / 2.55
2.23 / 2.55
3.12 / 3.57
25 + 25 + 25 + 25 + 35
2.50 / 2.85
2.50 / 2.85
2.50 / 2.85
2.50 / 2.85
3.50 / 3.99
22 + 25 + 25 + 25 + 25 + 50
1.79 / 2.05
2.03 / 2.33
2.03 / 2.33
2.03 / 2.33
2.03 / 2.33
4.07 / 4.65
Unit F
Unit G
Unit H
25 + 25 + 25 + 25 + 50
2.33 / 2.67
2.33 / 2.67
2.33 / 2.67
2.33 / 2.67
4.67 / 5.33
22 + 25 + 25 + 25 + 25 + 60
1.69 / 1.93
1.92 / 2.20
1.92 / 2.20
1.92 / 2.20
1.92 / 2.20
4.62 / 5.27
25 + 25 + 25 + 25 + 60
2.19 / 2.50
2.19 / 2.50
2.19 / 2.50
2.19 / 2.50
5.25 / 6.00
22 + 25 + 25 + 25 + 35 + 35
1.84 / 2.11
2.10 / 2.40
2.10 / 2.40
2.10 / 2.40
2.93 / 3.35
2.93 / 3.35
25 + 25 + 25 + 25 + 71
2.05 / 2.34
2.05 / 2.34
2.05 / 2.34
2.05 / 2.34
5.81 / 6.64
22 + 25 + 25 + 25 + 35 + 50
1.69 / 1.93
1.92 / 2.20
1.92 / 2.20
1.92 / 2.20
2.69 / 3.08
3.85 / 4.40
25 + 25 + 25 + 35 + 35
2.41 / 2.76
2.41 / 2.76
2.41 / 2.76
3.38 / 3.86
3.38 / 3.86
22 + 25 + 25 + 35 + 35 + 35
1.74 / 1.99
1.98 / 2.26
1.98 / 2.26
2.77 / 3.16
2.77 / 3.16
2.77 / 3.16
25 + 25 + 25 + 35 + 50
2.19 / 2.50
2.19 / 2.50
2.19 / 2.50
3.06 / 3.50
4.38 / 5.00
25 + 25 + 25 + 25 + 25 + 25
2.33 / 2.67
2.33 / 2.67
2.33 / 2.67
2.33 / 2.67
2.33 / 2.67
2.33 / 2.67
25 + 25 + 25 + 35 + 60
2.06 / 2.35
2.06 / 2.35
2.06 / 2.35
2.88 / 3.29
4.94 / 5.65
25 + 25 + 25 + 25 + 25 + 35
2.19 / 2.50
2.19 / 2.50
2.19 / 2.50
2.19 / 2.50
2.19 / 2.50
3.06 / 3.50
25 + 25 + 25 + 35 + 71
1.93 / 2.21
1.93 / 2.21
1.93 / 2.21
2.71 / 3.09
5.49 / 6.28
25 + 25 + 25 + 25 + 25 + 50
2.00 / 2.29
2.00 / 2.29
2.00 / 2.29
2.00 / 2.29
2.00 / 2.29
4.00 / 4.57
25 + 25 + 25 + 50 + 50
2.00 / 2.29
2.00 / 2.29
2.00 / 2.29
4.00 / 4.57
4.00 / 4.57
25 + 25 + 25 + 25 + 25 + 60
1.89 / 2.16
1.89 / 2.16
1.89 / 2.16
1.89 / 2.16
1.89 / 2.16
4.54 / 5.19
Unit G
25 + 25 + 25 + 50 + 60
1.89 / 2.16
1.89 / 2.16
1.89 / 2.16
3.78 / 4.32
4.54 / 5.19
25 + 25 + 25 + 25 + 35 + 35
2.06 / 2.35
2.06 / 2.35
2.06 / 2.35
2.06 / 2.35
2.88 / 3.29
2.88 / 3.29
25 + 25 + 35 + 35 + 35
2.26 / 2.58
2.26 / 2.58
3.16 / 3.61
3.16 / 3.61
3.16 / 3.61
25 + 25 + 25 + 25 + 35 + 50
1.89 / 2.16
1.89 / 2.16
1.89 / 2.16
1.89 / 2.16
2.65 / 3.03
3.78 / 4.32
25 + 25 + 35 + 35 + 50
2.06 / 2.35
2.06 / 2.35
2.88 / 3.29
2.88 / 3.29
4.12 / 4.71
25 + 25 + 25 + 35 + 35 + 35
1.94 / 2.22
1.94 / 2.22
1.94 / 2.22
2.72 / 3.11
2.72 / 3.11
2.72 / 3.11
25 + 25 + 35 + 35 + 60
1.94 / 2.22
1.94 / 2.22
2.72 / 3.11
2.72 / 3.11
4.67 / 5.33
25 + 25 + 35 + 50 + 50
1.89 / 2.16
1.89 / 2.16
2.65 / 3.03
3.78 / 4.32
3.78 / 4.32
25 + 35 + 35 + 35 + 35
2.12 / 2.42
2.97 / 3.39
2.97 / 3.39
2.97 / 3.39
2.97 / 3.39
25 + 35 + 35 + 35 + 50
1.94 / 2.22
2.72 / 3.11
2.72 / 3.11
2.72 / 3.11
3.89 / 4.44
35 + 35 + 35 + 35 + 35
2.80 / 3.20
2.80 / 3.20
2.80 / 3.20
2.80 / 3.20
2.80 / 3.20
22 + 22 + 22 + 22 + 22 + 22 + 22
2.00 / 2.29
2.00 / 2.29
2.00 / 2.29
2.00 / 2.29
2.00 / 2.29
2.00 / 2.29
2.00 / 2.29
22 + 22 + 22 + 22 + 22 + 22 + 25
1.96 / 2.24
1.96 / 2.24
1.96 / 2.24
1.96 / 2.24
1.96 / 2.24
1.96 / 2.24
2.23 / 2.55
Unit H
7 ROOMS
6 ROOMS 22 + 22 + 22 + 22 + 22 + 22
2.20 / 2.52
2.20 / 2.52
2.20 / 2.52
2.20 / 2.52
2.20 / 2.52
2.20 / 2.52
22 + 22 + 22 + 22 + 22 + 22 + 35
1.84 / 2.11
1.84 / 2.11
1.84 / 2.11
1.84 / 2.11
1.84 / 2.11
1.84 / 2.11
2.93 / 3.35
22 + 22 + 22 + 22 + 22 + 25
2.20 / 2.51
2.20 / 2.51
2.20 / 2.51
2.20 / 2.51
2.20 / 2.51
2.50 / 2.85
22 + 22 + 22 + 22 + 22 + 22 + 50
1.69 / 1.93
1.69 / 1.93
1.69 / 1.93
1.69 / 1.93
1.69 / 1.93
1.69 / 1.93
3.85 / 4.40
22 + 22 + 22 + 22 + 22 + 35
2.12 / 2.43
2.12 / 2.43
2.12 / 2.43
2.12 / 2.43
2.12 / 2.43
3.38 / 3.86
22 + 22 + 22 + 22 + 22 + 25 + 25
1.93 / 2.20
1.93 / 2.20
1.93 / 2.20
1.93 / 2.20
1.93 / 2.20
2.19 / 2.50
2.19 / 2.50
22 + 22 + 22 + 22 + 22 + 50
1.93 / 2.20
1.93 / 2.20
1.93 / 2.20
1.93 / 2.20
1.93 / 2.20
4.38 / 5.00
22 + 22 + 22 + 22 + 22 + 25 + 35
1.81 / 2.07
1.81 / 2.07
1.81 / 2.07
1.81 / 2.07
1.81 / 2.07
2.06 / 2.35
2.88 / 3.29
22 + 22 + 22 + 22 + 22 + 60
1.81 / 2.07
1.81 / 2.07
1.81 / 2.07
1.81 / 2.07
1.81 / 2.07
4.94 / 5.65
22 + 22 + 22 + 22 + 22 + 25 + 50
1.66 / 1.90
1.66 / 1.90
1.66 / 1.90
1.66 / 1.90
1.66 / 1.90
1.89 / 2.16
3.78 / 4.32
22 + 22 + 22 + 22 + 22 + 71
1.70 / 1.94
1.70 / 1.94
1.70 / 1.94
1.70 / 1.94
1.70 / 1.94
5.49 / 6.28
22 + 22 + 22 + 22 + 22 + 35 + 35
1.71 / 1.96
1.71 / 1.96
1.71 / 1.96
1.71 / 1.96
1.71 / 1.96
2.72 / 3.11
2.72 / 3.11
22 + 22 + 22 + 22 + 25 + 25
2.20 / 2.52
2.20 / 2.52
2.20 / 2.52
2.20 / 2.52
2.50 / 2.86
2.50 / 2.86
22 + 22 + 22 + 22 + 25 + 25 + 25
1.89 / 2.16
1.89 / 2.16
1.89 / 2.16
1.89 / 2.16
2.15 / 2.45
2.15 / 2.45
2.15 / 2.45
22 + 22 + 22 + 22 + 25 + 35
2.08 / 2.38
2.08 / 2.38
2.08 / 2.38
2.08 / 2.38
2.36 / 2.70
3.31 / 3.78
22 + 22 + 22 + 22 + 25 + 25 + 35
1.78 / 2.03
1.78 / 2.03
1.78 / 2.03
1.78 / 2.03
2.02 / 2.31
2.02 / 2.31
2.83 / 3.24
22 + 22 + 22 + 22 + 25 + 50
1.89 / 2.16
1.89 / 2.16
1.89 / 2.16
1.89 / 2.16
2.15 / 2.45
4.29 / 4.91
22 + 22 + 22 + 22 + 25 + 35 + 35
1.68 / 1.92
1.68 / 1.92
1.68 / 1.92
1.68 / 1.92
1.91 / 2.19
2.68 / 3.06
2.68 / 3.06
22 + 22 + 22 + 22 + 25 + 60
1.78 / 2.03
1.78 / 2.03
1.78 / 2.03
1.78 / 2.03
2.02 / 2.31
4.86 / 5.55
22 + 22 + 22 + 25 + 25 + 25 + 25
1.86 / 2.12
1.86 / 2.12
1.86 / 2.12
2.11 / 2.41
2.11 / 2.41
2.11 / 2.41
2.11 / 2.41
22 + 22 + 22 + 22 + 25 + 71
1.67 / 1.91
1.67 / 1.91
1.67 / 1.91
1.67 / 1.91
1.90 / 2.17
5.40 / 6.17
22 + 22 + 22 + 25 + 25 + 25 + 35
1.75 / 2.00
1.75 / 2.00
1.75 / 2.00
1.99 / 2.27
1.99 / 2.27
1.99 / 2.27
2.78 / 3.18
22 + 22 + 22 + 22 + 35 + 35
1.95 / 2.23
1.95 / 2.23
1.95 / 2.23
1.95 / 2.23
3.10 / 3.54
3.10 / 3.54
22 + 22 + 25 + 25 + 25 + 25 + 25
1.82 / 2.08
1.82 / 2.08
2.07 / 2.37
2.07 / 2.37
2.07 / 2.37
2.07 / 2.37
2.07 / 2.37
22 + 22 + 22 + 22 + 35 + 50
1.78 / 2.03
1.78 / 2.03
1.78 / 2.03
1.78 / 2.03
2.83 / 3.24
4.05 / 4.62
22 + 22 + 25 + 25 + 25 + 25 + 35
1.72 / 1.97
1.72 / 1.97
1.96 / 2.23
1.96 / 2.23
1.96 / 2.23
1.96 / 2.23
2.74 / 3.13
22 + 22 + 22 + 22 + 35 + 60
1.68 / 1.92
1.68 / 1.92
1.68 / 1.92
1.68 / 1.92
2.68 / 3.06
4.59 / 5.25
22 + 25 + 25 + 25 + 25 + 25 + 25
1.79 / 2.05
2.03 / 2.33
2.03 / 2.33
2.03 / 2.33
2.03 / 2.33
2.03 / 2.33
2.03 / 2.33
22 + 22 + 22 + 25 + 25 + 25
2.18 / 2.50
2.18 / 2.50
2.18 / 2.50
2.48 / 2.84
2.48 / 2.84
2.48 / 2.84
22 + 25 + 25 + 25 + 25 + 25 + 35
1.69 / 1.93
1.92 / 2.20
1.92 / 2.20
1.92 / 2.20
1.92 / 2.20
1.92 / 2.20
2.69 / 3.08
22 + 22 + 22 + 25 + 25 + 35
2.04 / 2.33
2.04 / 2.33
2.04 / 2.33
2.32 / 2.65
2.32 / 2.65
3.25 / 3.71
25 + 25 + 25 + 25 + 25 + 25 + 25
2.00 / 2.29
2.00 / 2.29
2.00 / 2.29
2.00 / 2.29
2.00 / 2.29
2.00 / 2.29
2.00 / 2.29
22 + 22 + 22 + 25 + 25 + 50
1.86 / 2.12
1.86 / 2.12
1.86 / 2.12
2.11 / 2.41
2.11 / 2.41
4.22 / 4.82
25 + 25 + 25 + 25 + 25 + 25 + 35
1.89 / 2.16
1.89 / 2.16
1.89 / 2.16
1.89 / 2.16
1.89 / 2.16
1.89 / 2.16
2.65 / 3.03
22 + 22 + 22 + 25 + 25 + 60
1.75 / 2.00
1.75 / 2.00
1.75 / 2.00
1.99 / 2.27
1.99 / 2.27
4.77 / 5.45
22 + 22 + 22 + 25 + 35 + 35
1.91 / 2.19
1.91 / 2.19
1.91 / 2.19
2.17 / 2.48
3.04 / 3.48
3.04 / 3.48
22 + 22 + 22 + 25 + 35 + 50
1.75 / 2.00
1.75 / 2.00
1.75 / 2.00
1.99 / 2.27
2.78 / 3.18
3.98 / 4.55
22 + 22 + 22 + 35 + 35 + 35
1.80 / 2.06
1.80 / 2.06
1.80 / 2.06
2.87 / 3.27
2.87 / 3.27
2.87 / 3.27
22 + 22 + 25 + 25 + 25 + 25
2.14 / 2.44
2.14 / 2.44
2.43 / 2.78
2.43 / 2.78
2.43 / 2.78
2.43 / 2.78
8 ROOMS
22 + 22 + 25 + 25 + 25 + 35
2.00 / 2.29
2.00 / 2.29
2.27 / 2.60
2.27 / 2.60
2.27 / 2.60
3.18 / 3.64
22 + 22 + 22 + 22 + 22 + 22 + 22 + 22
1.75 / 2.00
1.75 / 2.00
1.75 / 2.00
1.75 / 2.00
1.75 / 2.00
1.75 / 2.00
1.75 / 2.00
1.75 / 2.00
22 + 22 + 25 + 25 + 25 + 50
1.82 / 2.08
1.82 / 2.08
2.07 / 2.37
2.07 / 2.37
2.07 / 2.37
4.14 / 4.73
22 + 22 + 22 + 22 + 22 + 22 + 22 + 25
1.72 / 1.97
1.72 / 1.97
1.72 / 1.97
1.72 / 1.97
1.72 / 1.97
1.72 / 1.97
1.72 / 1.97
1.96 / 2.23
22 + 22 + 25 + 25 + 25 + 60
1.72 / 1.97
1.72 / 1.97
1.96 / 2.23
1.96 / 2.23
1.96 / 2.23
4.69 / 5.36
22 + 22 + 22 + 22 + 22 + 22 + 25 + 25
1.69 / 1.93
1.69 / 1.93
1.69 / 1.93
1.69 / 1.93
1.69 / 1.93
1.69 / 1.93
1.92 / 2.20
1.92 / 2.20
22 + 22 + 25 + 25 + 35 + 35
1.88 / 2.15
1.88 / 2.15
2.13 / 2.44
2.13 / 2.44
2.99 / 3.41
2.99 / 3.41
22 + 22 + 22 + 22 + 22 + 25 + 25 + 25
1.66 / 1.90
1.66 / 1.90
1.66 / 1.90
1.66 / 1.90
1.66 / 1.90
1.89 / 2.16
1.89 / 2.16
1.89 / 2.16
22 + 22 + 25 + 25 + 35 + 50
1.72 / 1.97
1.72 / 1.97
1.96 / 2.23
1.96 / 2.23
2.74 / 3.13
3.91 / 4.47
22 + 22 + 25 + 35 + 35 + 35
1.70 / 2.02
1.70 / 2.02
2.00 / 2.30
2.82 / 3.22
2.82 / 3.22
2.82 / 3.22
22 + 22 + 35 + 35 + 35 + 35
1.67 / 1.91
1.67 / 1.91
2.66 / 3.04
2.66 / 3.04
2.66 / 3.04
2.66 / 3.04
22 + 25 + 25 + 25 + 25 + 25
2.10 / 2.39
2.38 / 2.72
2.38 / 2.72
2.38 / 2.72
2.38 / 2.72
2.38 / 2.72
Page 50
Page 51
MXZ-8B160YA 1 Outdoor Unit Indoor unit combination
Indoor unit combination
Up to 8 Indoor Units Cooling / Heating Capacity (kW) Unit A
Unit B
Unit C
1 ROOM
Unit D
Cooling / Heating Capacity (kW)
Indoor unit combination
Cooling / Heating Capacity (kW)
Indoor unit combination
Unit A
Unit B
Unit C
Unit A
Unit B
Unit C
Unit A
Unit B
Unit C
Unit D
22 + 25 + 25
2.20 / 2.57
2.50 / 2.92
2.50 / 2.92
35 + 60 + 71
2.95 / 3.80
5.06 / 6.51
5.99 / 7.70
22 + 25 + 35 + 71
2.01 / 2.59
2.29 / 2.94
3.20 / 4.12
6.50 / 8.35
22 + 25 + 35
2.20 / 2.55
2.50 / 2.90
3.50 / 4.05
35 + 60 + 100
2.51 / 3.23
4.31 / 5.54
7.18 / 9.23
22 + 25 + 35 + 100 1.69 / 2.18
1.92 / 2.47
2.69 / 3.46
7.69 / 9.89
Unit D
Unit D
Cooling / Heating Capacity (kW)
22 + 25 + 50
2.20 / 2.56
2.50 / 2.91
5.00 / 5.82
35 + 71 + 71
2.77 / 3.56
5.62 / 7.22
5.62 / 7.22
22 + 25 + 50 + 50
2.10 / 2.69
2.38 / 3.06
4.76 / 6.12
4.76 / 6.12
22 + 25 + 60
2.20 / 2.55
2.50 / 2.90
6.00 / 6.95
50 + 50 + 50
4.67 / 6.00
4.67 / 6.00
4.67 / 6.00
22 + 25 + 50 + 60
1.96 / 2.52
2.23 / 2.87
4.46 / 5.73
5.35 / 6.88
50 + 50 + 60
4.38 / 5.63
4.38 / 5.63
5.25 / 6.75
22 + 25 + 50 + 71
1.83 / 2.36
2.08 / 2.68
4.17 / 5.36
5.92 / 7.61
50 + 50 + 71
4.09 / 5.26
4.09 / 5.26
5.81 / 7.47
22 + 25 + 50 + 100 1.56 / 2.01
1.78 / 2.28
3.55 / 4.57
7.11 / 9.14
22
2.20 / 3.30
22 + 25 + 71
2.20 / 2.55
2.50 / 2.90
7.10 / 8.24
25
2.50 / 3.60
22 + 25 + 100
2.10 / 2.69
2.38 / 3.06
9.52 / 12.24
35
3.50 / 4.00
22 + 35 + 35
2.20 / 2.56
3.50 / 4.07
3.50 / 4.07
50 + 50 + 100
3.50 / 4.50
3.50 / 4.50
7.00 / 9.00
22 + 25 + 60 + 60
1.84 / 2.37
2.10 / 2.69
5.03 / 6.47
5.03 / 6.47
50
5.00 / 7.20
22 + 35 + 50
2.20 / 2.55
3.50 / 4.06
5.00 / 5.79
50 + 60 + 60
4.12 / 5.29
4.94 / 6.35
4.94 / 6.35
22 + 25 + 60 + 71
1.73 / 2.22
1.97 / 2.53
4.72 / 6.07
5.58 / 7.18
60
6.00 / 7.90
22 + 35 + 60
2.20 / 2.56
3.50 / 4.07
6.00 / 6.97
50 + 60 + 71
3.87 / 4.97
4.64 / 5.97
5.49 / 7.06
22 + 25 + 71 + 71
1.63 / 2.10
1.85 / 2.38
5.26 / 6.76
5.26 / 6.76
71
7.10 / 8.60
22 + 35 + 71
2.20 / 2.56
3.50 / 4.07
7.10 / 8.26
50 + 71 + 71
3.65 / 4.69
5.18 / 6.66
5.18 / 6.66
22 + 35 + 35 + 35
2.20 / 2.55
3.50 / 4.05
3.50 / 4.05
3.50 / 4.05
10.00 / 11.20
22 + 35 + 100
1.96 / 2.52
3.12 / 4.01
8.92 / 11.46
60 + 60 + 60
4.67 / 6.00
4.67 / 6.00
4.67 / 6.00
22 + 35 + 35 + 50
2.17 / 2.79
3.45 / 4.44
3.45 / 4.44
4.93 / 6.34
22 + 50 + 50
2.20 / 2.56
5.00 / 5.82
5.00 / 5.82
60 + 60 + 71
4.40 / 5.65
4.40 / 5.65
5.20 / 6.69
22 + 35 + 35 + 60
2.03 / 2.61
3.22 / 4.14
3.22 / 4.14
5.53 / 7.11
22 + 50 + 60
2.20 / 2.55
5.00 / 5.80
6.00 / 6.95
60 + 71 + 71
4.16 / 5.35
4.92 / 6.33
4.92 / 6.33
22 + 35 + 35 + 71
1.89 / 2.43
3.01 / 3.87
3.01 / 3.87
6.10 / 7.84
2.20 / 2.55
22 + 50 + 71
2.15 / 2.77
4.90 / 6.29
6.95 / 8.94
22 + 35 + 35 + 100 1.60 / 2.06
2.55 / 3.28
2.55 / 3.28
7.29 / 9.38
22 + 35 + 50 + 50
1.96 / 2.52
3.12 / 4.01
4.46 / 5.73
4.46 / 5.73
22 + 35 + 50 + 60
1.84 / 2.37
2.93 / 3.77
4.19 / 5.39
5.03 / 6.47
100
2 ROOMS 22 + 22
2.20 / 2.55
22 + 25
2.20 / 2.57
2.50 / 2.93
22 + 50 + 100
1.79 / 2.30
4.07 / 5.23
8.14 / 10.47
22 + 35
2.20 / 2.55
3.50 / 4.05
22 + 60 + 60
2.17 / 2.79
5.92 / 7.61
5.92 / 7.61
4 ROOMS
22 + 50
2.20 / 2.57
5.00 / 5.83
22 + 60 + 71
2.01 / 2.59
5.49 / 7.06
6.50 / 8.35
22 + 22 + 22 + 22
2.20 / 2.55
2.20 / 2.55
2.20 / 2.55
2.20 / 2.55
22 + 35 + 50 + 71
1.73 / 2.22
2.75 / 3.54
3.93 / 5.06
5.58 / 7.18
22 + 60
2.20 / 2.55
6.00 / 6.95
22 + 60 + 100
1.69 / 2.18
4.62 / 5.93
7.69 / 9.89
22 + 22 + 22 + 25
2.20 / 2.56
2.20 / 2.56
2.20 / 2.56
2.50 / 2.91
22 + 35 + 60 + 60
1.74 / 2.24
2.77 / 3.56
4.75 / 6.10
4.75 / 6.10
7.10 / 8.25
22 + 71 + 71
2.20 / 2.55
2.20 / 2.55
2.20 / 2.55
3.50 / 4.05
22 + 35 + 60 + 71
22 + 71
2.20 / 2.55
1.88 / 2.41
6.06 / 7.79
6.06 / 7.79
22 + 22 + 22 + 35
1.64 / 2.11
2.61 / 3.35
4.47 / 5.74
5.29 / 6.80
22 + 100
2.20 / 2.56 10.00 / 11.64
22 + 71 + 100
1.60 / 2.05
5.15 / 6.62
7.25 / 9.33
22 + 22 + 22 + 50
2.20 / 2.56
2.20 / 2.56
2.20 / 2.56
5.00 / 5.82
22 + 35 + 71 + 71
1.55 / 1.99
2.46 / 3.17
4.99 / 6.42
4.99 / 6.42
25 + 25
2.50 / 2.90
2.50 / 2.90
25 + 25 + 25
2.50 / 2.90
2.50 / 2.90
2.50 / 2.90
22 + 22 + 22 + 60
2.20 / 2.55
2.20 / 2.55
2.20 / 2.55
6.00 / 6.95
22 + 50 + 50 + 50
1.79 / 2.30
4.07 / 5.23
4.07 / 5.23
4.07 / 5.23
25 + 35
2.50 / 2.92
3.50 / 4.08
25 + 25 + 35
2.50 / 2.91
2.50 / 2.91
3.50 / 4.08
22 + 22 + 22 + 71
2.20 / 2.55
2.20 / 2.55
2.20 / 2.55
7.10 / 8.24
22 + 50 + 50 + 60
1.69 / 2.18
3.85 / 4.95
3.85 / 4.95
4.62 / 5.93
1.86 / 2.39
1.86 / 2.39
8.43 / 10.84
22 + 50 + 50 + 71
25 + 50
2.50 / 2.90
5.00 / 5.80
25 + 25 + 50
2.50 / 2.90
2.50 / 2.90
5.00 / 5.80
22 + 22 + 22 + 100 1.86 / 2.39
1.60 / 2.05
3.63 / 4.66
3.63 / 4.66
5.15 / 6.62
25 + 60
2.50 / 2.91
6.00 / 6.99
25 + 25 + 60
2.50 / 2.91
2.50 / 2.91
6.00 / 6.98
22 + 22 + 25 + 25
2.20 / 2.55
2.20 / 2.55
2.50 / 2.90
2.50 / 2.90
22 + 50 + 60 + 60
1.60 / 2.06
3.65 / 4.69
4.38 / 5.63
4.38 / 5.63
25 + 71
2.50 / 2.89
7.10 / 8.21
25 + 25 + 71
2.50 / 2.91
2.50 / 2.91
7.10 / 8.27
22 + 22 + 25 + 35
2.20 / 2.56
2.20 / 2.56
2.50 / 2.91
3.50 / 4.07
22 + 60 + 60 + 60
1.52 / 1.96
4.16 / 5.35
4.16 / 5.35
4.16 / 5.35
25 + 100
2.50 / 2.90 10.00 / 11.60
25 + 25 + 100
2.33 / 3.00
2.33 / 3.00
9.33 / 12.00
22 + 22 + 25 + 50
2.20 / 2.55
2.20 / 2.55
2.50 / 2.90
5.00 / 5.80
25 + 25 + 25 + 25
2.50 / 2.90
2.50 / 2.90
2.50 / 2.90
2.50 / 2.90
35 + 35
3.50 / 4.05
3.50 / 4.05
25 + 35 + 35
2.50 / 2.89
3.50 / 4.05
3.50 / 4.05
22 + 22 + 25 + 60
2.20 / 2.56
2.20 / 2.56
2.50 / 2.91
6.00 / 6.98
25 + 25 + 25 + 35
2.50 / 2.91
2.50 / 2.91
2.50 / 2.91
3.50 / 4.07
35 + 50
3.50 / 4.08
5.00 / 5.82
25 + 35 + 50
2.50 / 2.91
3.50 / 4.07
5.00 / 5.82
22 + 22 + 25 + 71
2.20 / 2.83
2.20 / 2.83
2.50 / 3.21
7.10 / 9.13
25 + 25 + 25 + 50
2.50 / 2.90
2.50 / 2.90
2.50 / 2.90
5.00 / 5.80
35 + 60
3.50 / 4.05
6.00 / 6.95
25 + 35 + 60
2.50 / 2.90
3.50 / 4.05
6.00 / 6.95
22 + 22 + 25 + 100 1.82 / 2.34
1.82 / 2.34
2.07 / 2.66
8.28 / 10.65
25 + 25 + 25 + 60
2.50 / 2.91
2.50 / 2.91
2.50 / 2.91
6.00 / 6.98
35 + 71
3.50 / 4.06
7.10 / 8.24
25 + 35 + 71
2.50 /2.90
3.50 / 4.06
7.10 / 8.24
22 + 22 + 35 + 35
2.20 / 2.55
2.20 / 2.55
3.50 / 4.05
3.50 / 4.05
25 + 25 + 25 + 71
2.40 / 3.08
2.40 / 3.08
2.40 / 3.08
6.81 / 8.75
2.20 / 2.56
2.20 / 2.56
3.50 / 4.07
5.00 / 5.81
25 + 25 + 25 + 100 2.00 / 2.57
35 + 100
3.50 / 4.07 10.00 / 11.63
25 + 35 + 100
2.19 / 2.81
3.06 / 3.94
8.75 / 11.25
22 + 22 + 35 + 50
2.00 / 2.57
2.00 / 2.57
8.00 / 10.29
50 + 50
5.00 / 5.80
5.00 / 5.80
25 + 50 + 50
2.50 / 2.90
5.00 / 5.80
5.00 / 5.80
22 + 22 + 35 + 60
2.20 / 2.55
2.20 / 2.55
3.50 / 4.05
6.00 / 6.95
25 + 25 + 35 + 35
2.50 / 2.90
2.50 / 2.90
3.50 / 4.05
3.50 / 4.05
50 + 60
5.00 / 5.82
6.00 / 6.98
25 + 50 + 60
2.50 / 2.91
5.00 / 5.81
6.00 / 6.98
22 + 22 + 35 + 71
2.05 / 2.64
2.05 / 2.64
3.27 / 4.20
6.63 / 8.52
25 + 25 + 35 + 50
2.50 / 2.91
2.50 / 2.91
3.50 / 4.07
5.00 / 5.81
50 + 71
5.00 / 5.83
7.10 / 8.27
25 + 50 + 71
2.40 / 3.08
4.79 / 6.16
6.81 / 8.75
22 + 22 + 35 + 100 1.72 / 2.21
1.72 / 2.21
2.74 / 3.52
7.82 / 10.06
25 + 25 + 35 + 60
2.41 / 3.10
2.41 / 3.10
3.38 / 4.34
5.79 / 7.45
2.14 / 2.75
2.14 / 2.75
4.86 / 6.25
4.86 / 6.25
25 + 25 + 35 + 71
50 + 100
4.67 / 6.00
9.33 / 12.00
25 + 50 + 100
2.00 / 2.57
4.00 / 5.14
8.00 / 10.29
22 + 22 + 50 + 50
2.24 / 2.88
2.24 / 2.88
3.14 / 4.04
6.37 / 8.19
60 + 60
6.00 / 6.95
6.00 / 6.95
25 + 60 + 60
2.41 / 3.10
5.79 / 7.45
5.79 / 7.45
22 + 22 + 50 + 60
2.00 / 2.57
2.00 / 2.57
4.55 / 5.84
5.45 / 7.01
25 + 25 + 35 + 100 1.89 / 2.43
1.89 / 2.43
2.65 / 3.41
7.57 / 9.73
60 + 71
6.00 / 6.96
7.10 / 8.24
25 + 60 + 71
2.24 / 2.88
5.38 / 6.92
6.37 / 8.19
22 + 22 + 50 + 71
1.87 / 2.40
1.87 / 2.40
4.24 / 5.45
6.02 / 7.75
25 + 25 + 50 + 50
2.33 / 3.00
2.33 / 3.00
4.67 / 6.00
4.67 / 6.00
60 + 100
5.25 / 6.75
8.75 / 11.25
25 + 60 + 100
1.89 / 2.43
4.54 / 5.84
7.57 / 9.73
22 + 22 + 50 + 100 1.59 / 2.04
1.59 / 2.04
3.61 / 4.64
7.22 / 9.28
25 + 25 + 50 + 60
2.19 / 2.81
2.19 / 2.81
4.38 / 5.63
5.25 / 6.75
25 + 71 + 71
2.10 / 2.69
5.95 / 7.65
5.95 / 7.65
22 + 22 + 60 + 60
1.88 / 2.41
1.88 / 2.41
5.12 / 6.59
5.12 / 6.59
25 + 25 + 50 + 71
2.05 / 2.63
2.05 / 2.63
4.09 / 5.26
5.81 / 7.47
25 + 71 + 100
1.79 / 2.30
5.07 / 6.52
7.14 / 9.18
22 + 22 + 60 + 71
1.76 / 2.26
1.76 / 2.26
4.80 / 6.17
5.68 / 7.30
25 + 25 + 50 + 100 1.75 / 2.25
1.75 / 2.25
3.50 / 4.50
7.00 / 9.00
35 + 35 + 35
3.50 / 4.07
3.50 / 4.07
3.50 / 4.07
22 + 22 + 71 + 71
1.66 / 2.13
1.66 / 2.13
5.34 / 6.87
5.34 / 6.87
25 + 25 + 60 + 60
2.06 / 2.65
2.06 / 2.65
4.94 / 6.35
4.94 / 6.35
35 + 35 + 50
3.50 / 4.05
3.50 / 4.05
5.00 / 5.79
22 + 25 + 25 + 25
2.20 / 2.56
2.50 / 2.91
2.50 / 2.91
2.50 / 2.91
25 + 25 + 60 + 71
1.93 / 2.49
1.93 / 2.49
4.64 / 5.97
5.49 / 7.06
2.20 / 2.55
2.50 / 2.90
2.50 / 2.90
3.50 / 4.06
25 + 25 + 71 + 71
71 + 71
7.00 / 9.00
7.00 / 9.00
71 + 100
5.81 / 7.47
8.19 / 10.53
100 + 100
7.00 / 9.00
7.00 / 9.00
足
3 ROOMS
3.50 / 4.07
3.50 / 4.07
6.00 / 6.97
22 + 25 + 25 + 35
1.82 / 2.34
1.82 / 2.34
5.18 / 6.66
5.18 / 6.66
22 + 22 + 22
2.20 / 2.57
2.20 / 2.57
2.20 / 2.57
35 + 35 + 71
3.48 / 4.47
3.48 / 4.47
7.05 / 9.06
22 + 25 + 25 + 50
2.20 / 2.56
2.50 / 2.91
2.50 / 2.91
5.00 / 5.82
25 + 35 + 35 + 35
2.50 / 2.90
3.50 / 4.07
3.50 / 4.07
3.50 / 4.07
22 + 22 + 25
2.20 / 2.55
2.20 / 2.55
2.50 / 2.90
35 + 35 + 100
2.88 / 3.71
2.88 / 3.71
8.24 / 10.59
22 + 25 + 25 + 60
2.20 / 2.55
2.50 / 2.90
2.50 / 2.90
6.00 / 6.95
25 + 35 + 35 + 50
2.41 / 3.10
3.38 / 4.34
3.38 / 4.34
4.83 / 6.21
22 + 22 + 35
2.20 / 2.56
2.20 / 2.56
3.50 / 4.08
35 + 50 + 50
3.50 / 4.07
5.00 / 5.81
5.00 / 5.81
22 + 25 + 25 + 71
2.15 / 2.77
2.45 / 3.15
2.45 / 3.15
6.95 / 8.94
25 + 35 + 35 + 60
2.26 / 2.90
3.16 / 4.06
3.16 / 4.06
5.42 / 6.97
2.03 / 2.62
2.03 / 2.62
8.14 / 10.47
25 + 35 + 35 + 71
35 + 35 + 60
22 + 22 + 50
2.20 / 2.55
2.20 / 2.55
5.00 / 5.80
35 + 50 + 60
3.38 / 4.34
4.83 / 6.21
5.79 / 7.45
22 + 25 + 25 + 100 1.79 / 2.30
2.11 / 2.71
2.95 / 3.80
2.95 / 3.80
5.99 / 7.70
22 + 22 + 60
2.20 / 2.56
2.20 / 2.56
6.00 / 6.98
35 + 50 + 71
3.14 / 4.04
4.49 / 5.77
6.37 / 8.19
22 + 25 + 35 + 35
2.20 / 2.56
2.50 / 2.91
3.50 / 4.07
3.50 / 4.07
25 + 35 + 35 + 100 1.79 / 2.31
2.51 / 3.23
2.51 / 3.23
7.18 / 9.23
22 + 22 + 71
2.20 / 2.56
2.20 / 2.56
7.10 / 8.27
35 + 50 + 100
2.65 / 3.41
3.78 / 4.86
7.57 / 9.73
22 + 25 + 35 + 50
2.20 / 2.55
2.50 / 2.90
3.50 / 4.06
5.00 / 5.80
25 + 35 + 50 + 50
2.19 / 2.81
3.06 / 3.94
4.38 / 5.63
4.38 / 5.63
22 + 22 + 100
2.14 / 2.75
2.14 / 2.75
9.72 / 12.50
35 + 60 + 60
3.16 / 4.06
5.42 / 6.97
5.42 / 6.97
22 + 25 + 35 + 60
2.17 / 2.79
2.46 / 3.17
3.45 / 4.44
5.92 / 7.61
25 + 35 + 50 + 60
2.06 / 2.65
2.88 / 3.71
4.12 / 5.29
4.94 / 6.35
Page 52
Page 53
Indoor unit combination
Indoor unit combination
Cooling / Heating Capacity (kW)
Cooling / Heating Capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit A
Unit B
Unit C
Unit D
Unit E
25 + 35 + 50 + 71
1.93 / 2.49
2.71 / 3.48
3.87 / 4.97
5.49 / 7.06
22 + 22 + 25 + 25 + 71
1.87 / 2.40
1.87 / 2.40
2.12 / 2.73
2.12 / 2.73
6.02 / 7.75
25 + 35 + 60 + 60
1.94 / 2.50
2.72 / 3.50
4.67 / 6.00
4.67 / 6.00
22 + 22 + 25 + 25 + 100
1.59 / 2.04
1.59 / 2.04
1.80 / 2.32
1.80 / 2.32
7.22 / 9.28
25 + 35 + 60 + 71
1.83 / 2.36
2.57 / 3.30
4.40 / 5.65
5.20 / 6.69
22 + 22 + 25 + 35 + 35
2.20 / 2.55
2.20 / 2.55
2.50 / 2.90
3.50 / 4.05
3.50 / 4.05
25 + 35 + 71 + 71
1.73 / 2.23
2.43 / 3.12
4.92 / 6.33
4.92 / 6.33
22 + 22 + 25 + 35 + 50
2.00 / 2.57
2.00 / 2.57
2.27 / 2.92
3.18 / 4.09
4.55 / 5.84
25 + 50 + 50 + 50
2.00 / 2.57
4.00 / 5.14
4.00 / 5.14
4.00 / 5.14
22 + 22 + 25 + 35 + 60
1.88 / 2.41
1.88 / 2.41
2.13 / 2.74
2.99 / 3.84
5.12 / 6.59
Unit E
Unit F
Unit G
Unit H
25 + 50 + 50 + 60
1.89 / 2.43
3.78 / 4.86
3.78 / 4.86
4.54 / 5.84
22 + 22 + 25 + 35 + 71
1.76 / 2.26
1.76 / 2.26
2.00 / 2.57
2.80 / 3.60
5.68 / 7.30
25 + 50 + 50 + 71
1.79 / 2.30
3.57 / 4.59
3.57 / 4.59
5.07 / 6.52
22 + 22 + 25 + 50 + 50
1.82 / 2.34
1.82 / 2.34
2.07 / 2.66
4.14 / 5.33
4.14 / 5.33
25 + 50 + 60 + 60
1.79 / 2.31
3.59 / 4.62
4.31 / 5.54
4.31 / 5.54
22 + 22 + 25 + 50 + 60
1.72 / 2.21
1.72 / 2.21
1.96 / 2.51
3.91 / 5.03
4.69 / 6.03
35 + 35 + 35 + 35
3.50 / 4.50
3.50 / 4.50
3.50 / 4.50
3.50 / 4.50
22 + 22 + 25 + 50 + 71
1.62 / 2.08
1.62 / 2.08
1.84 / 2.37
3.68 / 4.74
5.23 / 6.73
35 + 35 + 35 + 50
3.16 / 4.06
3.16 / 4.06
3.16 / 4.06
4.52 / 5.81
22 + 22 + 25 + 60 + 60
1.63 / 2.10
1.63 / 2.10
1.85 / 2.38
4.44 / 5.71
4.44 / 5.71
35 + 35 + 35 + 60
2.97 / 3.82
2.97 / 3.82
2.97 / 3.82
5.09 / 6.55
22 + 22 + 25 + 60 + 71
1.54 / 1.98
1.54 / 1.98
1.75 / 2.25
4.20 / 5.40
4.97 / 6.39
35 + 35 + 35 + 71
2.78 / 3.58
2.78 / 3.58
2.78 / 3.58
5.65 / 7.26
22 + 22 + 35 + 35 + 35
2.07 / 2.66
2.07 / 2.66
3.29 / 4.23
3.29 / 4.23
3.29 / 4.23
35 + 35 + 50 + 50
2.88 / 3.71
2.88 / 3.71
4.12 / 5.29
4.12 / 5.29
22 + 22 + 35 + 35 + 50
1.88 / 2.41
1.88 / 2.41
2.99 / 3.84
2.99 / 3.84
4.27 / 5.49
35 + 35 + 50 + 60
2.72 / 3.50
2.72 / 3.50
3.89 / 5.00
4.67 / 6.00
22 + 22 + 35 + 35 + 60
1.77 / 2.28
1.77 / 2.28
2.82 / 3.62
2.82 / 3.62
4.83 / 6.21
35 + 35 + 50 + 71
2.57 / 3.30
2.57 / 3.30
3.66 / 4.71
5.20 / 6.69
22 + 22 + 35 + 35 + 71
1.66 / 2.14
1.66 / 2.14
2.65 / 3.41
2.65 / 3.41
5.37 / 6.91
35 + 35 + 60 + 60
2.58 / 3.32
2.58 / 3.32
4.42 / 5.68
4.42 / 5.68
22 + 22 + 35 + 50 + 50
1.72 / 2.21
1.72 / 2.21
2.74 / 3.52
3.91 / 5.03
3.91 / 5.03
35 + 35 + 60 + 71
2.44 / 3.13
2.44 / 3.13
4.18 / 5.37
4.95 / 6.36
22 + 22 + 35 + 50 + 60
1.63 / 2.10
1.63 / 2.10
2.59 / 3.33
3.70 / 4.76
4.44 / 5.71
35 + 50 + 50 + 50
2.65 / 3.41
3.78 / 4.86
3.78 / 4.86
3.78 / 4.86
22 + 22 + 35 + 50 + 71
1.54 / 1.98
1.54 / 1.98
2.45 / 3.15
3.50 / 4.50
4.97 / 6.39
35 + 50 + 50 + 60
2.51 / 3.23
3.59 / 4.62
3.59 / 4.62
4.31 / 5.54
22 + 22 + 35 + 60 + 60
1.55 / 1.99
1.55 / 1.99
2.46 / 3.17
4.22 / 5.43
4.22 / 5.43
50 + 50 + 50 + 50
3.50 / 4.50
3.50 / 4.50
3.50 / 4.50
3.50 / 4.50
22 + 22 + 50 + 50 + 50
1.59 / 2.04
1.59 / 2.04
3.61 / 4.64
3.61 / 4.64
3.61 / 4.64
22 + 25 + 25 + 25 + 25
2.20 / 2.56
2.50 / 2.91
2.50 / 2.91
2.50 / 2.91
2.50 / 2.91
22 + 25 + 25 + 25 + 35
2.20 / 2.55
2.50 / 2.90
2.50 / 2.90
2.50 / 2.90
3.50 / 4.06
2.20 / 2.56
22 + 25 + 25 + 25 + 50
2.10 / 2.69
2.38 / 3.06
2.38 / 3.06
2.38 / 3.06
4.76 / 6.12
2.50 / 2.90
22 + 25 + 25 + 25 + 60
1.96 / 2.52
2.23 / 2.87
2.23 / 2.87
2.23 / 2.87
5.35 / 6.88
5 ROOMS 22 + 22 + 22 + 22 + 22 22 + 22 + 22 + 22 + 25
2.20 / 2.56 2.20 / 2.55
2.20 / 2.56 2.20 / 2.55
2.20 / 2.56 2.20 / 2.55
2.20 / 2.56 2.20 / 2.55
22 + 22 + 22 + 22 + 35
2.20 / 2.56
2.20 / 2.56
2.20 / 2.56
2.20 / 2.56
3.50 / 4.07
22 + 25 + 25 + 25 + 71
1.83 / 2.36
2.08 / 2.68
2.08 / 2.68
2.08 / 2.68
5.92 / 7.61
22 + 22 + 22 + 22 + 50
2.20 / 2.55
2.20 / 2.55
2.20 / 2.55
2.20 / 2.55
5.00 / 5.80
22 + 25 + 25 + 25 + 100
1.56 / 2.01
1.78 / 2.28
1.78 / 2.28
1.78 / 2.28
7.11 / 9.14
22 + 22 + 22 + 22 + 60
2.08 / 2.68
2.08 / 2.68
2.08 / 2.68
2.08 / 2.68
5.68 / 7.30
22 + 25 + 25 + 35 + 35
2.17 / 2.79
2.46 / 3.17
2.46 / 3.17
3.45 / 4.44
3.45 / 4.44
1.96 / 2.52
2.23 / 2.87
2.23 / 2.87
3.12 / 4.01
4.46 / 5.73
22 + 22 + 22 + 22 + 71
1.94 / 2.49
1.94 / 2.49
1.94 / 2.49
1.94 / 2.49
6.25 / 8.04
22 + 25 + 25 + 35 + 50
22 + 22 + 22 + 22 + 100
1.64 / 2.11
1.64 / 2.11
1.64 / 2.11
1.64 / 2.11
7.45 / 9.57
22 + 25 + 25 + 35 + 60
1.84 / 2.37
2.10 / 2.69
2.10 / 2.69
2.93 / 3.77
5.03 / 6.47
22 + 22 + 22 + 25 + 25
2.20 / 2.56
2.20 / 2.56
2.20 / 2.56
2.50 / 2.91
2.50 / 2.91
22 + 25 + 25 + 35 + 71
1.73 / 2.22
1.97 / 2.53
1.97 / 2.53
2.75 / 3.54
5.58 / 7.18
22 + 22 + 22 + 25 + 35
2.20 / 2.55
2.20 / 2.55
2.20 / 2.55
2.50 / 2.90
3.50 / 4.06
22 + 25 + 25 + 50 + 50
1.79 / 2.30
2.03 / 2.62
2.03 / 2.62
4.07 / 5.23
4.07 / 5.23
1.69 / 2.18
1.92 / 2.47
1.92 / 2.47
3.85 / 4.95
4.62 / 5.93
22 + 22 + 22 + 25 + 50
2.18 / 2.81
2.18 / 2.81
2.18 / 2.81
2.48 / 3.19
4.96 / 6.38
22 + 25 + 25 + 50 + 60
22 + 22 + 22 + 25 + 60
2.04 / 2.62
2.04 / 2.62
2.04 / 2.62
2.32 / 2.98
5.56 / 7.15
22 + 25 + 25 + 50 + 71
1.60 / 2.05
1.81 / 2.33
1.81 / 2.33
3.63 / 4.66
5.15 / 6.62
22 + 22 + 22 + 25 + 71
1.90 / 2.44
1.90 / 2.44
1.90 / 2.44
2.16 / 2.78
6.14 / 7.89
22 + 25 + 25 + 60 + 60
1.60 / 2.06
1.82 / 2.34
1.82 / 2.34
4.38 / 5.63
4.38 / 5.63
22 + 22 + 22 + 25 + 100
1.61 / 2.07
1.61 / 2.07
1.61 / 2.07
1.83 / 2.36
7.33 / 9.42
22 + 25 + 35 + 35 + 35
2.03 / 2.61
2.30 / 2.96
3.22 / 4.14
3.22 / 4.14
3.22 / 4.14
22 + 22 + 22 + 35 + 35
2.20 / 2.56
2.20 / 2.56
2.20 / 2.56
3.50 / 4.07
3.50 / 4.07
22 + 25 + 35 + 35 + 50
1.84 / 2.37
2.10 / 2.69
2.93 / 3.77
2.93 / 3.77
4.19 / 5.39
22 + 22 + 22 + 35 + 50
2.04 / 2.62
2.04 / 2.62
2.04 / 2.62
3.25 / 4.17
4.64 / 5.96
22 + 25 + 35 + 35 + 60
1.74 / 2.24
1.98 / 2.54
2.77 / 3.56
2.77 / 3.56
4.75 / 6.10
22 + 22 + 22 + 35 + 60
1.91 / 2.46
1.91 / 2.46
1.91 / 2.46
3.04 / 3.91
5.22 / 6.71
22 + 25 + 35 + 35 + 71
1.64 / 2.11
1.86 / 2.39
2.61 / 3.35
2.61 / 3.35
5.29 / 6.80
22 + 22 + 22 + 35 + 71
1.79 / 2.30
1.79 / 2.30
1.79 / 2.30
2.85 / 3.66
5.78 / 7.43
22 + 25 + 35 + 50 + 50
1.69 / 2.18
1.92 / 2.47
2.69 / 3.46
3.85 / 4.95
3.85 / 4.95
22 + 22 + 22 + 35 + 100
1.53 / 1.97
1.53 / 1.97
1.53 / 1.97
2.44 / 3.13
6.97 / 8.96
22 + 25 + 35 + 50 + 60
1.60 / 2.06
1.82 / 2.34
2.55 / 3.28
3.65 / 4.69
4.38 / 5.63
22 + 22 + 22 + 50 + 50
1.86 / 2.39
1.86 / 2.39
1.86 / 2.39
4.22 / 5.42
4.22 / 5.42
22 + 25 + 35 + 60 + 60
1.52 / 1.96
1.73 / 2.23
2.43 / 3.12
4.16 / 5.35
4.16 / 5.35
22 + 22 + 22 + 50 + 60
1.75 / 2.25
1.75 / 2.25
1.75 / 2.25
3.98 / 5.11
4.77 / 6.14
22 + 25 + 50 + 50 + 50
1.56 / 2.01
1.78 / 2.28
3.55 / 4.57
3.55 / 4.57
3.55 / 4.57
22 + 22 + 22 + 50 + 71
1.65 / 2.12
1.65 / 2.12
1.65 / 2.12
3.74 / 4.81
5.32 / 6.83
22 + 35 + 35 + 35 + 35
1.90 / 2.44
3.02 / 3.89
3.02 / 3.89
3.02 / 3.89
3.02 / 3.89
22 + 22 + 22 + 60 + 60
1.66 / 2.13
1.66 / 2.13
1.66 / 2.13
4.52 / 5.81
4.52 / 5.81
22 + 35 + 35 + 35 + 50
1.74 / 2.24
2.77 / 3.56
2.77 / 3.56
2.77 / 3.56
3.95 / 5.08
22 + 22 + 22 + 60 + 71
1.56 / 2.01
1.56 / 2.01
1.56 / 2.01
4.26 / 5.48
5.05 / 6.49
22 + 35 + 35 + 35 + 60
1.65 / 2.12
2.62 / 3.37
2.62 / 3.37
2.62 / 3.37
4.49 / 5.78
22 + 22 + 25 + 25 + 25
2.20 / 2.55
2.20 / 2.55
2.50 / 2.90
2.50 / 2.90
2.50 / 2.90
22 + 35 + 35 + 35 + 71
1.56 / 2.00
2.47 / 3.18
2.47 / 3.18
2.47 / 3.18
5.02 / 6.45
22 + 22 + 25 + 25 + 35
2.20 / 2.56
2.20 / 2.56
2.50 / 2.91
2.50 / 2.91
3.50 / 4.07
22 + 35 + 35 + 50 + 50
1.60 / 2.06
2.55 / 3.28
2.55 / 3.28
3.65 / 4.69
3.65 / 4.69
1.52 / 1.96
2.43 / 3.12
2.43 / 3.12
3.47 / 4.46
4.16 / 5.35
2.50 / 2.90
2.50 / 2.90
2.50 / 2.90
2.50 / 2.90
2.50 / 2.90
22 + 22 + 25 + 25 + 50
2.14 / 2.75
2.14 / 2.75
2.43 / 3.13
2.43 / 3.13
4.86 / 6.25
22 + 35 + 35 + 50 + 60
22 + 22 + 25 + 25 + 60
2.00 / 2.57
2.00 / 2.57
2.27 / 2.92
2.27 / 2.92
5.45 / 7.01
25 + 25 + 25 + 25 + 25
Page 54
Unit F
Unit G
Unit H
Page 55
Indoor unit combination
Indoor unit combination
Cooling / Heating Capacity (kW) Unit F
Unit G
Unit H
Cooling / Heating Capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit E
Unit A
Unit B
Unit C
Unit D
Unit E
Unit F
25 + 25 + 25 + 25 + 35
2.50 / 2.91
2.50 / 2.91
2.50 / 2.91
2.50 / 2.91
3.50 / 4.07
22 + 22 + 22 + 25 + 25 + 50
1.86 / 2.39
1.86 / 2.39
1.86 / 2.39
2.11 / 2.71
2.11 / 2.71
4.22 / 5.42
25 + 25 + 25 + 25 + 50
2.33 / 3.00
2.33 / 3.00
2.33 / 3.00
2.33 / 3.00
4.67 / 6.00
22 + 22 + 22 + 25 + 25 + 60
1.75 / 2.25
1.75 / 2.25
1.75 / 2.25
1.99 / 2.56
1.99 / 2.56
4.77 / 6.14
25 + 25 + 25 + 25 + 60
2.19 / 2.81
2.19 / 2.81
2.19 / 2.81
2.19 / 2.81
5.25 / 6.75
22 + 22 + 22 + 25 + 25 + 71
1.65 / 2.12
1.65 / 2.12
1.65 / 2.12
1.87 / 2.41
1.87 / 2.41
5.32 / 6.83
25 + 25 + 25 + 25 + 71
2.05 / 2.63
2.05 / 2.63
2.05 / 2.63
2.05 / 2.63
5.81 / 7.47
22 + 22 + 22 + 25 + 35 + 35
1.91 / 2.46
1.91 / 2.46
1.91 / 2.46
2.17 / 2.80
3.04 / 3.91
3.04 / 3.91
25 + 25 + 25 + 25 + 100
1.75 / 2.25
1.75 / 2.25
1.75 / 2.25
1.75 / 2.25
7.00 / 9.00
22 + 22 + 22 + 25 + 35 + 50
1.75 / 2.25
1.75 / 2.25
1.75 / 2.25
1.99 / 2.56
2.78 / 3.58
3.98 / 5.11
25 + 25 + 25 + 35 + 35
2.41 / 3.10
2.41 / 3.10
2.41 / 3.10
3.38 / 4.34
3.38 / 4.34
22 + 22 + 22 + 25 + 35 + 60
1.66 / 2.13
1.66 / 2.13
1.66 / 2.13
1.88 / 2.42
2.63 / 3.39
4.52 / 5.81
25 + 25 + 25 + 35 + 50
2.19 / 2.81
2.19 / 2.81
2.19 / 2.81
3.06 / 3.94
4.38 / 5.63
22 + 22 + 22 + 25 + 35 + 71
1.56 / 2.01
1.56 / 2.01
1.56 / 2.01
1.78 / 2.28
2.49 / 3.20
5.05 / 6.49
25 + 25 + 25 + 35 + 60
2.06 / 2.65
2.06 / 2.65
2.06 / 2.65
2.88 / 3.71
4.94 / 6.35
22 + 22 + 22 + 25 + 50 + 50
1.61 / 2.07
1.61 / 2.07
1.61 / 2.07
1.83 / 2.36
3.66 / 4.71
3.66 / 4.71
25 + 25 + 25 + 35 + 71
1.93 / 2.49
1.93 / 2.49
1.93 / 2.49
2.71 / 3.48
5.49 / 7.06
22 + 22 + 22 + 25 + 50 + 60
1.53 / 1.97
1.53 / 1.97
1.53 / 1.97
1.74 / 2.24
3.48 / 4.48
4.18 / 5.37
25 + 25 + 25 + 50 + 50
2.00 / 2.57
2.00 / 2.57
2.00 / 2.57
4.00 / 5.14
4.00 / 5.14
22 + 22 + 22 + 35 + 35 + 35
1.80 / 2.32
1.80 / 2.32
1.80 / 2.32
2.87 / 3.68
2.87 / 3.68
2.87 / 3.68
25 + 25 + 25 + 50 + 60
1.89 / 2.43
1.89 / 2.43
1.89 / 2.43
3.78 / 4.86
4.54 / 5.84
22 + 22 + 22 + 35 + 35 + 50
1.66 / 2.13
1.66 / 2.13
1.66 / 2.13
2.63 / 3.39
2.63 / 3.39
3.76 / 4.84
25 + 25 + 25 + 50 + 71
1.79 / 2.30
1.79 / 2.30
1.79 / 2.30
3.57 / 4.59
5.07 / 6.52
22 + 22 + 22 + 35 + 35 + 60
1.57 / 2.02
1.57 / 2.02
1.57 / 2.02
2.50 / 3.21
2.50 / 3.21
4.29 / 5.51
25 + 25 + 25 + 60 + 60
1.79 / 2.31
1.79 / 2.31
1.79 / 2.31
4.31 / 5.54
4.31 / 5.54
22 + 22 + 22 + 35 + 50 + 50
1.53 / 1.97
1.53 / 1.97
1.53 / 1.97
2.44 / 3.13
3.48 / 4.48
3.48 / 4.48
25 + 25 + 35 + 35 + 35
2.26 / 2.90
2.26 / 2.90
3.16 / 4.06
3.16 / 4.06
3.16 / 4.06
22 + 22 + 25 + 25 + 25 + 25
2.14 / 2.75
2.14 / 2.75
2.43 / 3.13
2.43 / 3.13
2.43 / 3.13
2.43 / 3.13
25 + 25 + 35 + 35 + 50
2.06 / 2.65
2.06 / 2.65
2.88 / 3.71
2.88 / 3.71
4.12 / 5.29
22 + 22 + 25 + 25 + 25 + 35
2.00 / 2.57
2.00 / 2.57
2.27 / 2.92
2.27 / 2.92
2.27 / 2.92
3.18 / 4.09
25 + 25 + 35 + 35 + 60
1.94 / 2.50
1.94 / 2.50
2.72 / 3.50
2.72 / 3.50
4.67 / 6.00
22 + 22 + 25 + 25 + 25 + 50
1.82 / 2.34
1.82 / 2.34
2.07 / 2.66
2.07 / 2.66
2.07 / 2.66
4.14 / 5.33
25 + 25 + 35 + 35 + 71
1.83 / 2.36
1.83 / 2.36
2.57 / 3.30
2.57 / 3.30
5.20 / 6.69
22 + 22 + 25 + 25 + 25 + 60
1.72 / 2.21
1.72 / 2.21
1.96 / 2.51
1.96 / 2.51
1.96 / 2.51
4.69 / 6.03
25 + 25 + 35 + 50 + 50
1.89 / 2.43
1.89 / 2.43
2.65 / 3.41
3.78 / 4.86
3.78 / 4.86
22 + 22 + 25 + 25 + 25 + 71
1.62 / 2.08
1.62 / 2.08
1.84 / 2.37
1.84 / 2.37
1.84 / 2.37
5.23 / 6.73
25 + 25 + 35 + 50 + 60
1.79 / 2.31
1.79 / 2.31
2.51 / 3.23
3.59 / 4.62
4.31 / 5.54
22 + 22 + 25 + 25 + 35 + 35
1.88 / 2.41
1.88 / 2.41
2.13 / 2.74
2.13 / 2.74
2.99 / 3.84
2.99 / 3.84
25 + 25 + 50 + 50 + 50
1.75 / 2.25
1.75 / 2.25
3.50 / 4.50
3.50 / 4.50
3.50 / 4.50
22 + 22 + 25 + 25 + 35 + 50
1.72 / 2.21
1.72 / 2.21
1.96 / 2.51
1.96 / 2.51
2.74 / 3.52
3.91 / 5.03
25 + 35 + 35 + 35 + 35
2.12 / 2.73
2.97 / 3.82
2.97 / 3.82
2.97 / 3.82
2.97 / 3.82
22 + 22 + 25 + 25 + 35 + 60
1.63 / 2.10
1.63 / 2.10
1.85 / 2.38
1.85 / 2.38
2.59 / 3.33
4.44 / 5.71
25 + 35 + 35 + 35 + 50
1.94 / 2.50
2.72 / 3.50
2.72 / 3.50
2.72 / 3.50
3.89 / 5.00
22 + 22 + 25 + 25 + 35 + 71
1.54 / 1.98
1.54 / 1.98
1.75 / 2.25
1.75 / 2.25
2.45 / 3.15
4.97 / 6.39
25 + 35 + 35 + 35 + 60
1.84 / 2.37
2.58 / 3.32
2.58 / 3.32
2.58 / 3.32
4.42 / 5.68
22 + 22 + 25 + 25 + 50 + 50
1.59 / 2.04
1.59 / 2.04
1.80 / 2.32
1.80 / 2.32
3.61 / 4.64
3.61 / 4.64
25 + 35 + 35 + 35 + 71
1.74 / 2.24
2.44 / 3.13
2.44 / 3.13
2.44 / 3.13
4.95 / 6.36
22 + 22 + 25 + 35 + 35 + 35
1.77 / 2.28
1.77 / 2.28
2.01 / 2.59
2.82 / 3.62
2.82 / 3.62
2.82 / 3.62
25 + 35 + 35 + 50 + 50
1.79 / 2.31
2.51 / 3.23
2.51 / 3.23
3.59 / 4.62
3.59 / 4.62
22 + 22 + 25 + 35 + 35 + 50
1.63 / 2.10
1.63 / 2.10
1.85 / 2.38
2.59 / 3.33
2.59 / 3.33
3.70 / 4.76
35 + 35 + 35 + 35 + 35
2.80 / 3.60
2.80 / 3.60
2.80 / 3.60
2.80 / 3.60
2.80 / 3.60
22 + 22 + 25 + 35 + 35 + 60
1.55 / 1.99
1.55 / 1.99
1.76 / 2.26
2.46 / 3.17
2.46 / 3.17
4.22 / 5.43
35 + 35 + 35 + 35 + 50
2.58 / 3.32
2.58 / 3.32
2.58 / 3.32
2.58 / 3.32
3.68 / 4.74
22 + 22 + 35 + 35 + 35 + 35
1.67 / 2.15
1.67 / 2.15
2.66 / 3.42
2.66 / 3.42
2.66 / 3.42
2.66 / 3.42
35 + 35 + 35 + 35 + 60
2.45 / 3.15
2.45 / 3.15
2.45 / 3.15
2.45 / 3.15
4.20 / 5.40
22 + 22 + 35 + 35 + 35 + 50
1.55 / 1.99
1.55 / 1.99
2.46 / 3.17
2.46 / 3.17
2.46 / 3.17
3.52 / 4.52
22 + 25 + 25 + 25 + 25 + 25
2.10 / 2.69
2.38 / 3.06
2.38 / 3.06
2.38 / 3.06
2.38 / 3.06
2.38 / 3.06
22 + 25 + 25 + 25 + 25 + 35
1.96 / 2.52
2.23 / 2.87
2.23 / 2.87
2.23 / 2.87
2.23 / 2.87
3.12 / 4.01
22 + 25 + 25 + 25 + 25 + 50
6 ROOMS
1.79 / 2.30
2.03 / 2.62
2.03 / 2.62
2.03 / 2.62
2.03 / 2.62
4.07 / 5.23
22 + 22 + 22 + 22 + 22 + 22
2.20 / 2.55
2.20 / 2.55
2.20 / 2.55
2.20 / 2.55
2.20 / 2.55
2.20 / 2.55
22 + 25 + 25 + 25 + 25 + 60
1.69 / 2.18
1.92 / 2.47
1.92 / 2.47
1.92 / 2.47
1.92 / 2.47
4.62 / 5.93
22 + 22 + 22 + 22 + 22 + 25
2.20 / 2.56
2.20 / 2.56
2.20 / 2.56
2.20 / 2.56
2.20 / 2.56
2.50 / 2.91
22 + 25 + 25 + 25 + 25 + 71
1.60 / 2.05
1.81 / 2.33
1.81 / 2.33
1.81 / 2.33
1.81 / 2.33
5.15 / 6.62
22 + 22 + 22 + 22 + 22 + 35
2.12 / 2.73
2.12 / 2.73
2.12 / 2.73
2.12 / 2.73
2.12 / 2.73
3.38 / 4.34
22 + 25 + 25 + 25 + 35 + 35
1.84 / 2.37
2.10 / 2.69
2.10 / 2.69
2.10 / 2.69
2.93 / 3.77
2.93 / 3.77
22 + 22 + 22 + 22 + 22 + 50
1.93 / 2.48
1.93 / 2.48
1.93 / 2.48
1.93 / 2.48
1.93 / 2.48
4.38 / 5.63
22 + 25 + 25 + 25 + 35 + 50
1.69 / 2.18
1.92 / 2.47
1.92 / 2.47
1.92 / 2.47
2.69 / 3.46
3.85 / 4.95
22 + 22 + 22 + 22 + 22 + 60
1.81 / 2.33
1.81 / 2.33
1.81 / 2.33
1.81 / 2.33
1.81 / 2.33
4.94 / 6.35
22 + 25 + 25 + 25 + 35 + 60
1.60 / 2.06
1.82 / 2.34
1.82 / 2.34
1.82 / 2.34
2.55 / 3.28
4.38 / 5.63
22 + 22 + 22 + 22 + 22 + 71
1.70 / 2.19
1.70 / 2.19
1.70 / 2.19
1.70 / 2.19
1.70 / 2.19
5.49 / 7.06
22 + 25 + 25 + 25 + 50 + 50
1.56 / 2.01
1.78 / 2.28
1.78 / 2.28
1.78 / 2.28
3.55 / 4.57
3.55 / 4.57
22 + 22 + 22 + 22 + 25 + 25
2.20 / 2.55
2.20 / 2.55
2.20 / 2.55
2.20 / 2.55
2.50 / 2.90
2.50 / 2.90
22 + 25 + 25 + 35 + 35 + 35
1.74 / 2.24
1.98 / 2.54
1.98 / 2.54
2.77 / 3.56
2.77 / 3.56
2.77 / 3.56
22 + 22 + 22 + 22 + 25 + 35
2.08 / 2.68
2.08 / 2.68
2.08 / 2.68
2.08 / 2.68
2.36 / 3.04
3.31 / 4.26
22 + 25 + 25 + 35 + 35 + 50
1.60 / 2.06
1.82 / 2.34
1.82 / 2.34
2.55 / 3.28
2.55 / 3.28
3.65 / 4.69
22 + 22 + 22 + 22 + 25 + 50
1.89 / 2.43
1.89 / 2.43
1.89 / 2.43
1.89 / 2.43
2.15 / 2.76
4.29 / 5.52
22 + 25 + 25 + 35 + 35 + 60
1.52 / 1.96
1.73 / 2.23
1.73 / 2.23
2.43 / 3.12
2.43 / 3.12
4.16 / 5.35
22 + 22 + 22 + 22 + 25 + 60
1.78 / 2.29
1.78 / 2.29
1.78 / 2.29
1.78 / 2.29
2.02 / 2.60
4.86 / 6.24
22 + 25 + 35 + 35 + 35 + 35
1.65 / 2.12
1.87 / 2.41
2.62 / 3.37
2.62 / 3.37
2.62 / 3.37
2.62 / 3.37
22 + 22 + 22 + 22 + 25 + 71
1.67 / 2.15
1.67 / 2.15
1.67 / 2.15
1.67 / 2.15
1.90 / 2.45
5.40 / 6.95
22 + 25 + 35 + 35 + 35 + 50
1.52 / 1.96
1.73 / 2.23
2.43 / 3.12
2.43 / 3.12
2.43 / 3.12
3.47 / 4.46
22 + 22 + 22 + 22 + 35 + 35
1.95 / 2.51
1.95 / 2.51
1.95 / 2.51
1.95 / 2.51
3.10 / 3.99
3.10 / 3.99
22 + 35 + 35 + 35 + 35 + 35
1.56 / 2.01
2.49 / 3.20
2.49 / 3.20
2.49 / 3.20
2.49 / 3.20
2.49 / 3.20
22 + 22 + 22 + 22 + 35 + 50
1.78 / 2.29
1.78 / 2.29
1.78 / 2.29
1.78 / 2.29
2.83 / 3.64
4.05 / 5.20
25 + 25 + 25 + 25 + 25 + 25
2.33 / 3.00
2.33 / 3.00
2.33 / 3.00
2.33 / 3.00
2.33 / 3.00
2.33 / 3.00
22 + 22 + 22 + 22 + 35 + 60
1.68 / 2.16
1.68 / 2.16
1.68 / 2.16
1.68 / 2.16
2.68 / 3.44
4.59 / 5.90
25 + 25 + 25 + 25 + 25 + 35
2.19 / 2.81
2.19 / 2.81
2.19 / 2.81
2.19 / 2.81
2.19 / 2.81
3.06 / 3.94
22 + 22 + 22 + 22 + 35 + 71
1.59 / 2.04
1.59 / 2.04
1.59 / 2.04
1.59 / 2.04
2.53 / 3.25
5.12 / 6.59
25 + 25 + 25 + 25 + 25 + 50
2.00 / 2.57
2.00 / 2.57
2.00 / 2.57
2.00 / 2.57
2.00 / 2.57
4.00 / 5.14
22 + 22 + 22 + 22 + 50 + 50
1.64 / 2.11
1.64 / 2.11
1.64 / 2.11
1.64 / 2.11
3.72 / 4.79
3.72 / 4.79
25 + 25 + 25 + 25 + 25 + 60
1.89 / 2.43
1.89 / 2.43
1.89 / 2.43
1.89 / 2.43
1.89 / 2.43
4.54 / 5.84
22 + 22 + 22 + 22 + 50 + 60
1.56 / 2.00
1.56 / 2.00
1.56 / 2.00
1.56 / 2.00
3.54 / 4.55
4.24 / 5.45
25 + 25 + 25 + 25 + 25 + 71
1.79 / 2.30
1.79 / 2.30
1.79 / 2.30
1.79 / 2.30
1.79 / 2.30
5.07 / 6.52
22 + 22 + 22 + 25 + 25 + 25
2.18 / 2.81
2.18 / 2.81
2.18 / 2.81
2.48 / 3.19
2.48 / 3.19
2.48 / 3.19
25 + 25 + 25 + 25 + 35 + 35
2.06 / 2.65
2.06 / 2.65
2.06 / 2.65
2.06 / 2.65
2.88 / 3.71
2.88 / 3.71
22 + 22 + 22 + 25 + 25 + 35
2.04 / 2.62
2.04 / 2.62
2.04 / 2.62
2.32 / 2.98
2.32 / 2.98
3.25 / 4.17
25 + 25 + 25 + 25 + 35 + 50
1.89 / 2.43
1.89 / 2.43
1.89 / 2.43
1.89 / 2.43
2.65 / 3.41
3.78 / 4.86
Page 56
Unit G
Unit H
Page 57
Indoor unit combination
Indoor unit combination
Cooling / Heating Capacity (kW) Unit A
Unit B
Unit C
Unit D
Unit E
Unit F
25 + 25 + 25 + 25 + 35 + 60
1.79 / 2.31
1.79 / 2.31
1.79 / 2.31
1.79 / 2.31
2.51 / 3.23
4.31 / 5.54
25 + 25 + 25 + 25 + 50 + 50
1.75 / 2.25
1.75 / 2.25
1.75 / 2.25
1.75 / 2.25
3.50 / 4.50
3.50 / 4.50
25 + 25 + 25 + 35 + 35 + 35
1.94 / 2.50
1.94 / 2.50
1.94 / 2.50
2.72 / 3.50
2.72 / 3.50
2.72 / 3.50
25 + 25 + 25 + 35 + 35 + 50
1.79 / 2.31
1.79 / 2.31
1.79 / 2.31
2.51 / 3.23
2.51 / 3.23
25 + 25 + 35 + 35 + 35 + 35
1.84 / 2.37
1.84 / 2.37
2.58 / 3.32
2.58 / 3.32
25 + 35 + 35 + 35 + 35 + 35
1.75 / 2.25
2.45 / 3.15
2.45 / 3.15
2.45 / 3.15
Unit G
Unit H
Cooling / Heating Capacity (kW) Unit A
Unit B
Unit C
Unit D
Unit E
Unit F
Unit G
Unit H
22 + 22 + 22 + 22 + 22 + 22 + 22 + 22
1.75 / 2.25
1.75 / 2.25
1.75 / 2.25
1.75 / 2.25
1.75 / 2.25
1.75 / 2.25
1.75 / 2.25
1.75 / 2.25
3.59 / 4.62
22 + 22 + 22 + 22 + 22 + 22 + 22 + 25
1.72 / 2.21
1.72 / 2.21
1.72 / 2.21
1.72 / 2.21
1.72 / 2.21
1.72 / 2.21
1.72 / 2.21
1.96 / 2.51
2.58 / 3.32
2.58 / 3.32
22 + 22 + 22 + 22 + 22 + 22 + 22 + 35
1.63 / 2.10
1.63 / 2.10
1.63 / 2.10
1.63 / 2.10
1.63 / 2.10
1.63 / 2.10
1.63 / 2.10
2.59 / 3.33
2.45 / 3.15
2.45 / 3.15
22 + 22 + 22 + 22 + 22 + 22 + 25 + 25
1.69 / 2.18
1.69 / 2.18
1.69 / 2.18
1.69 / 2.18
1.69 / 2.18
1.69 / 2.18
1.92 / 2.47
1.92 / 2.47
22 + 22 + 22 + 22 + 22 + 22 + 25 + 35
1.60 / 2.06
1.60 / 2.06
1.60 / 2.06
1.60 / 2.06
1.60 / 2.06
1.60 / 2.06
1.82 / 2.34
2.55 / 3.28
22 + 22 + 22 + 22 + 22 + 22 + 35 + 35
1.52 / 1.96
1.52 / 1.96
1.52 / 1.96
1.52 / 1.96
1.52 / 1.96
1.52 / 1.96
2.43 / 3.12
2.43 / 3.12
22 + 22 + 22 + 22 + 22 + 25 + 25 + 25
1.66 / 2.14
1.66 / 2.14
1.66 / 2.14
1.66 / 2.14
1.66 / 2.14
1.89 / 2.43
1.89 / 2.43
1.89 / 2.43
22 + 22 + 22 + 22 + 22 + 25 + 25 + 35
1.58 / 2.03
1.58 / 2.03
1.58 / 2.03
1.58 / 2.03
1.58 / 2.03
1.79 / 2.31
1.79 / 2.31
2.51 / 3.23
8 ROOMS
7 ROOMS 22 + 22 + 22 + 22 + 22 + 22 + 22
2.00 / 2.57
2.00 / 2.57
2.00 / 2.57
2.00 / 2.57
2.00 / 2.57
2.00 / 2.57
2.00 / 2.57
22 + 22 + 22 + 22 + 25 + 25 + 25 + 25
1.64 / 2.11
1.64 / 2.11
1.64 / 2.11
1.64 / 2.11
1.86 / 2.39
1.86 / 2.39
1.86 / 2.39
1.86 / 2.39
22 + 22 + 22 + 22 + 22 + 22 + 25
1.96 / 2.52
1.96 / 2.52
1.96 / 2.52
1.96 / 2.52
1.96 / 2.52
1.96 / 2.52
2.23 / 2.87
22 + 22 + 22 + 22 + 25 + 25 + 25 + 35
1.56 / 2.00
1.56 / 2.00
1.56 / 2.00
1.56 / 2.00
1.77 / 2.27
1.77 / 2.27
1.77 / 2.27
2.47 / 3.18
22 + 22 + 22 + 22 + 22 + 22 + 35
1.84 / 2.37
1.84 / 2.37
1.84 / 2.37
1.84 / 2.37
1.84 / 2.37
1.84 / 2.37
2.93 / 3.77
22 + 22 + 22 + 25 + 25 + 25 + 25 + 25
1.61 / 2.07
1.61 / 2.07
1.61 / 2.07
1.83 / 2.36
1.83 / 2.36
1.83 / 2.36
1.83 / 2.36
1.83 / 2.36
22 + 22 + 22 + 22 + 22 + 22 + 50
1.69 / 2.18
1.69 / 2.18
1.69 / 2.18
1.69 / 2.18
1.69 / 2.18
1.69 / 2.18
3.85 / 4.95
22 + 22 + 22 + 25 + 25 + 25 + 25 + 35
1.53 / 1.97
1.53 / 1.97
1.53 / 1.97
1.74 / 2.24
1.74 / 2.24
1.74 / 2.24
1.74 / 2.24
2.44 / 3.13
22 + 22 + 22 + 22 + 22 + 22 + 60
1.60 / 2.06
1.60 / 2.06
1.60 / 2.06
1.60 / 2.06
1.60 / 2.06
1.60 / 2.06
4.38 / 5.63
22 + 22 + 25 + 25 + 25 + 25 + 25 + 25
1.59 / 2.04
1.59 / 2.04
1.80 / 2.32
1.80 / 2.32
1.80 / 2.32
1.80 / 2.32
1.80 / 2.32
1.80 / 2.32
22 + 22 + 22 + 22 + 22 + 25 + 25
1.93 / 2.48
1.93 / 2.48
1.93 / 2.48
1.93 / 2.48
1.93 / 2.48
2.19 / 2.81
2.19 / 2.81
22 + 25 + 25 + 25 + 25 + 25 + 25 + 25
1.56 / 2.01
1.78 / 2.28
1.78 / 2.28
1.78 / 2.28
1.78 / 2.28
1.78 / 2.28
1.78 / 2.28
1.78 / 2.28
22 + 22 + 22 + 22 + 22 + 25 + 35
1.81 / 2.33
1.81 / 2.33
1.81 / 2.33
1.81 / 2.33
1.81 / 2.33
2.06 / 2.65
2.88 / 3.71
25 + 25 + 25 + 25 + 25 + 25 + 25 + 25
1.75 / 2.25
1.75 / 2.25
1.75 / 2.25
1.75 / 2.25
1.75 / 2.25
1.75 / 2.25
1.75 / 2.25
1.75 / 2.25
22 + 22 + 22 + 22 + 22 + 25 + 50
1.66 / 2.14
1.66 / 2.14
1.66 / 2.14
1.66 / 2.14
1.66 / 2.14
1.89 / 2.43
3.78 / 4.86
22 + 22 + 22 + 22 + 22 + 25 + 60
1.58 / 2.03
1.58 / 2.03
1.58 / 2.03
1.58 / 2.03
1.58 / 2.03
1.79 / 2.31
4.31 / 5.54
22 + 22 + 22 + 22 + 22 + 35 + 35
1.71 / 2.20
1.71 / 2.20
1.71 / 2.20
1.71 / 2.20
1.71 / 2.20
2.72 / 3.50
2.72 / 3.50
22 + 22 + 22 + 22 + 22 + 35 + 50
1.58 / 2.03
1.58 / 2.03
1.58 / 2.03
1.58 / 2.03
1.58 / 2.03
2.51 / 3.23
3.59 / 4.62
22 + 22 + 22 + 22 + 25 + 25 + 25
1.89 / 2.43
1.89 / 2.43
1.89 / 2.43
1.89 / 2.43
2.15 / 2.76
2.15 / 2.76
2.15 / 2.76
22 + 22 + 22 + 22 + 25 + 25 + 35
1.78 / 2.29
1.78 / 2.29
1.78 / 2.29
1.78 / 2.29
2.02 / 2.60
2.02 / 2.60
2.83 / 3.64
22 + 22 + 22 + 22 + 25 + 25 + 50
1.64 / 2.11
1.64 / 2.11
1.64 / 2.11
1.64 / 2.11
1.86 / 2.39
1.86 / 2.39
3.72 / 4.79
22 + 22 + 22 + 22 + 25 + 25 + 60
1.56 / 2.00
1.56 / 2.00
1.56 / 2.00
1.56 / 2.00
1.77 / 2.27
1.77 / 2.27
4.24 / 5.45
22 + 22 + 22 + 22 + 25 + 35 + 35
1.68 / 2.16
1.68 / 2.16
1.68 / 2.16
1.68 / 2.16
1.91 / 2.46
2.68 / 3.44
2.68 / 3.44
22 + 22 + 22 + 22 + 25 + 35 + 50
1.56 / 2.00
1.56 / 2.00
1.56 / 2.00
1.56 / 2.00
1.77 / 2.27
2.47 / 3.18
3.54 / 4.55
22 + 22 + 22 + 22 + 35 + 35 + 35
1.60 / 2.05
1.60 / 2.05
1.60 / 2.05
1.60 / 2.05
2.54 / 3.26
2.54 / 3.26
2.54 / 3.26
22 + 22 + 22 + 25 + 25 + 25 + 25
1.86 / 2.39
1.86 / 2.39
1.86 / 2.39
2.11 / 2.71
2.11 / 2.71
2.11 / 2.71
2.11 / 2.71
22 + 22 + 22 + 25 + 25 + 25 + 35
1.75 / 2.25
1.75 / 2.25
1.75 / 2.25
1.99 / 2.56
1.99 / 2.56
1.99 / 2.56
2.78 / 3.58
22 + 22 + 22 + 25 + 25 + 25 + 50
1.61 / 2.07
1.61 / 2.07
1.61 / 2.07
1.83 / 2.36
1.83 / 2.36
1.83 / 2.36
3.66 / 4.71
22 + 22 + 22 + 25 + 25 + 25 + 60
1.53 / 1.97
1.53 / 1.97
1.53 / 1.97
1.74 / 2.24
1.74 / 2.24
1.74 / 2.24
4.18 / 5.37
22 + 22 + 22 + 25 + 25 + 35 + 35
1.66 / 2.13
1.66 / 2.13
1.66 / 2.13
1.88 / 2.42
1.88 / 2.42
2.63 / 3.39
2.63 / 3.39
22 + 22 + 22 + 25 + 25 + 35 + 50
1.53 / 1.97
1.53 / 1.97
1.53 / 1.97
1.74 / 2.24
1.74 / 2.24
2.44 / 3.13
3.48 / 4.48
22 + 22 + 22 + 25 + 35 + 35 + 35
1.57 / 2.02
1.57 / 2.02
1.57 / 2.02
1.79 / 2.30
2.50 / 3.21
2.50 / 3.21
2.50 / 3.21
22 + 22 + 25 + 25 + 25 + 25 + 25
1.82 / 2.34
1.82 / 2.34
2.07 / 2.66
2.07 / 2.66
2.07 / 2.66
2.07 / 2.66
2.07 / 2.66
22 + 22 + 25 + 25 + 25 + 25 + 35
1.72 / 2.21
1.72 / 2.21
1.96 / 2.51
1.96 / 2.51
1.96 / 2.51
1.96 / 2.51
2.74 / 3.52
22 + 22 + 25 + 25 + 25 + 25 + 50
1.59 / 2.04
1.59 / 2.04
1.80 / 2.32
1.80 / 2.32
1.80 / 2.32
1.80 / 2.32
3.61 / 4.64
22 + 22 + 25 + 25 + 25 + 35 + 35
1.63 / 2.10
1.63 / 2.10
1.85 / 2.38
1.85 / 2.38
1.85 / 2.38
2.59 / 3.33
2.59 / 3.33
22 + 22 + 25 + 25 + 35 + 35 + 35
1.55 / 1.99
1.55 / 1.99
1.76 / 2.26
1.76 / 2.26
2.46 / 3.17
2.46 / 3.17
2.46 / 3.17
22 + 25 + 25 + 25 + 25 + 25 + 25
1.79 / 2.30
2.03 / 2.62
2.03 / 2.62
2.03 / 2.62
2.03 / 2.62
2.03 / 2.62
2.03 / 2.62
22 + 25 + 25 + 25 + 25 + 25 + 35
1.69 / 2.18
1.92 / 2.47
1.92 / 2.47
1.92 / 2.47
1.92 / 2.47
1.92 / 2.47
2.69 / 3.46
22 + 25 + 25 + 25 + 25 + 25 + 50
1.56 / 2.01
1.78 / 2.28
1.78 / 2.28
1.78 / 2.28
1.78 / 2.28
1.78 / 2.28
3.55 / 4.57
22 + 25 + 25 + 25 + 25 + 35 + 35
1.60 / 2.06
1.82 / 2.34
1.82 / 2.34
1.82 / 2.34
1.82 / 2.34
2.55 / 3.28
2.55 / 3.28
22 + 25 + 25 + 25 + 35 + 35 + 35
1.52 / 1.96
1.73 / 2.23
1.73 / 2.23
1.73 / 2.23
2.43 / 3.12
2.43 / 3.12
2.43 / 3.12
25 + 25 + 25 + 25 + 25 + 25 + 25
2.00 / 2.57
2.00 / 2.57
2.00 / 2.57
2.00 / 2.57
2.00 / 2.57
2.00 / 2.57
2.00 / 2.57
25 + 25 + 25 + 25 + 25 + 25 + 35
1.89 / 2.43
1.89 / 2.43
1.89 / 2.43
1.89 / 2.43
1.89 / 2.43
1.89 / 2.43
2.65 / 3.41
25 + 25 + 25 + 25 + 25 + 25 + 50
1.75 / 2.25
1.75 / 2.25
1.75 / 2.25
1.75 / 2.25
1.75 / 2.25
1.75 / 2.25
3.50 / 4.50
25 + 25 + 25 + 25 + 25 + 35 + 35
1.79 / 2.31
1.79 / 2.31
1.79 / 2.31
1.79 / 2.31
1.79 / 2.31
2.51 / 3.23
2.51 / 3.23
Page 58
Page 59
MUZ-HC25/35VA(B)
>
Upper View
Side View
>
>
Front View
MUZ-GE25/35VA / MUZ-FD25/35VABH / SUZ-KA25/35VA2
>
>
>
Upper View
Side View
Side View
>
417.5
>
Air in
40
>
Air out 175
>
840
81
109
880
Front View
500
Outdoor Unit Dimensions
Front View
Side View
MUZ-GE60/71VA
330
Upper View
>
360
Front View
>
50
Upper View
MUZ-GE50VA / SUZ-KA50VA2
452
35
164.5
99.5
44
Dimensions
195
Page 60
M Series Range
Outdoor Units
Dimensions
Page 61
M Series Range
Accessories / Optional Extras M Series Catechin Filter
MAC-3003CF
- for MSZ-HC25/35VA(B) (10 pack)
Anti-Allergy Enzyme Filters
MAC-408FT-E MAC-2310FT-E MAC-415FT-E
- for MSZ-GE22-50VA (10 pack) - for MSZ-GE60/71VA (10 pack) - for MFZ-KA25-50VA (10 pack)
Wired Remote controller
PAR-30MAA
- for MSZ-GE22-71VA, MSZ-FD25/35VA & MFZ-KA25-50VA
Interfaces
MAC-399IF
- for connection to M-NET system
MAC-397IF
- for Contact Terminal, PAR-30MAA Wired Remote Controller
MAC-889SG
- for MXZ-2C52VA, MUZ-HC, MUZ-GE & MUZ-FD
MAC-856SG
- for MXZ-3C54VA, MXZ-4C71VA, MXZ-4C80VA & MXZ-5C100VA
Air Outlet Guides
PAC-SG59SG-E - for MXZ-8B140VA, MXZ-8B160YA
Accessories / Optional Extras
MXZ-8B Connection Pipe
Page 62
PAC-AK52YP-E - Y shaped pipe for MXZ-8B models enabling size 100 connection (PLA-RP)
Mr Slim Packaged Split-System Air Conditioning
Air Conditioning Commercial Heating Domestic Heating Photovoltaics
The Mr Slim Range Compact and Versatile, the Options are Endless
Easy to fit wherever you need
Suitable to heat or cool a huge variety of applications, the Mr Slim range is one of Britain’s best selling air conditioning split-systems. Combine the efficiency with the complete versatility that this range has to offer and the possibilities are virtually infinite. The 2011 Mr Slim range has been updated with new features, as well as the already impressive efficiency levels being improved. New to the range is an improved Standard Inverter offering, now also available as a 3-phase option. Complementing this, the Mr Slim Zubadan Inverter range of outdoor units guarantee heating operation down to -25ºC ambient air temperature, allowing set temperatures to be reached faster. The Mr Slim range has reached a new level of energy efficiency with the incorporation of new technologies and a new body design. These innovations will result in lower running costs and emissions throughout the life of a system. The side flow configuration of the outdoor unit, maximum piping length of 120m and Replace Technology help to simplify installation and make Mr Slim units more than just physically compact and discreet. They are also amongst the quietest operating units available, which means that apart from enjoying a comfortable, controllable environment, users hardly know Mr Slim is there at all.
An installers favourite, the excellent design of the Mr Slim range ensures quick and simple installation with the minimum of disruption. With extensive pipe runs of up to 120m, this versatile range makes it easier to select a layout to install the unit.
Page 64
Page 65
Power Inver ter
Silent Operation Operation has been made near-silent (67% quieter than corresponding R22 outdoor unit*1) as a result of improvement in the design of the fan blades and the new grille shape. The Power Inverter is even quieter at night when outside temperatures drop, as it can be set to low-noise mode (cooling only) reducing operating noise by 3dBA (50% quieter than normal day mode).
The Mr Slim Power Inverter range is now stronger than ever. The technological developments applied to this range of equipment offer the end user some of the highest energy efficiency ratings available, alongside greater application flexibility. This range is available in single and 3-phase options, the latter having running currents that are more than half that of the single phase option, offering a clear benefit to business premises that already have 3-phase supply installed. All models have low starting currents of 5 amps.
Improved COP / EER Ratings COP and EER ratings have increased across the board with the introduction of the VHA4 and VKA/YKA models. Many systems within our range now having energy labels of ‘A’ in both heating and cooling.
A low-noise priority function is also available by connecting a separate commercially available timer or selector switch. When a signal is received from the timer or switch, the unit automatically runs in low-noise mode.
Highly Efficient Fan and Grille
Existing R22/R407c Pipe Work
Outdoor Unit Fan Opening Increased <RP100-250> The diameter of the fan opening in the outdoor unit has been increased from 490 to 550mm. Discharge volume has been increased, while maintaining the same fan rotation speed.
The Mr Slim Power Inverter can reduce power consumption by up to 70% compared to a previously installed non-inverter model*1, making the energy cost savings associated with this range truly remarkable. A high power function also delivers increased capacity at times of high demand, allowing the room target temperature to be reached as rapidly as possible from start up.
When comparing the Power Inverter (PUHZ-RP71VHA4) with R22 (PUH3-VKA) in cooling.
The shapes of the fan and grille of the outdoor unit have been redesigned, realising an increase in discharge volume and a more efficient heat exchange, while maintaining the same operating noise level.
The issue of using existing pipe work has been resolved using Mitsubishi Electric’s unique ‘Replace Technology’, offering the opportunity to upgrade older, less efficient systems with the minimum of cost and installation disruption.
Reducing Power Consumption by 70%
*1
Grille Shape Changed
<RP60-250>
The shape of the air outlet grille has been changed to reduce pressure loss. This has helped improve heat exchange performance.
Highly Efficient Heat Exchanger A reduction in pipe diameter and an increase in surface area have improved the overall efficiency of the heat exchanger.
New Inflexed Fan
<RP100-250>
The adoption of a fan with improved ventilation characteristics and a newly designed rear edge that suppresses wind turbulence raises fan operation efficiency.
High-Density Heat Exchanger
Heat-Exchange Surface Area Increased <RP100-250> The heat exchanger size has been extended horizontally, increasing the surface area.
<RP100-250>
The pipe diameter for the RP100-140 has been changed from 9.52 to 7.94mm, the same diameter as that used for RP200-250 units, resulting in a high-density heat exchanger.
2 lines, 52 columns 2 lines, 64 columns
Increase in heat-exchanger surface area
Heat Interchanger Circuit (HIC) Added <RP140> *1 Based on the following operating conditions - Place-Office in Tokyo, Japan / Operating time-8am to 8pm, 6 days/week / Operating period-Cooling: April 16 - November 8. Heating: December 14 - March 23 / Set temperature-Cooling: 27°C, Heating: 20˚C. Non-inverter model installed eight years ago is a PLH-3GKHB / PUH-3YKA. Power Inverter model is a PLA-RP71BA2 / PUHZ-RP71VHA4.
Page 66
An HIC has been added to improve energy efficiency during cooling operation. Liquid refrigerant is rerouted, transformed into a gas state and injected back into the system to increase overall pressure of the refrigerant being sent to the compressor, thereby reducing the load on the compressor and raising efficiency.
Page 67
Standard Inverter The Standard Inverter models provide an inverter solution at a lower capital cost than the Power Inverter range. These outdoor models continue to offer high efficiency as standard, with some systems qualifying for Enhanced Capital Allowance. Models are available in 10, 12.5 & 14kW single phase and new for 2011, in 3-phase 10, 12.5, 14, 19 and 22kW sizes.
New 3-phase models now available
Improved COP / EER Figures
Improved Fan Design and Weight
COP / EER figures have been improved when compared to the previous R407c range.
The 10kW model has a compact single fan design and weighs less when compared to its Power Inverter equivalent, making installation easier.
SUZ outdoor units
are able to be connected to selected Mr Slim indoor units, creating a new range of low cost inverter driven systems.
Example: Height reduced by 395mm Power 116kg Inverter
Weight reduced by 41kg Standard 75kg Inverter
Low noise mode can be set at night time to reduce noise levels by 1/2 the audible sound approximately 50%. (compared to
330mm
daytime)
The example here is using a PUHZ-P100VHA3
Day 50dBA Outdoor Temperature 35ยบC
3dBA Less
943mm
Silent Outdoor Unit - Low Noise Mode
1338mm
395mm
1050mm
330mm
950mm
Duty Standby Operation
Night 47dBA Outdoor Temperature 25ยบC
Design with Environmental Consideration:
3 new functions are available with Mr Slim systems* : 1
Pump down switch Pushing a switch starts / stops refrigerant recovery operation automatically. This process will then be completed by closing a valve.
Rotate
Rotation 2 outdoor units (master & slave) operate alternately, switching every 1, 3, 5, 7, 14, 28 days (selectable).
Back Up
Back Up When master outdoor unit fails, sub unit begins operation.
Pump down switch
Join In
Join In When master outdoor unit fails to reach set temperature, sub unit operates in conjunction (available in cooling mode only).
Smooth refrigerant recovery can be assured by pushing the pump down switch at unit movement / renewal.
Page 68
* 1 Not available when using SUZ outdoor units. Must be used in conjunction with a PAR-30MAA controller.
Page 69
Mitsubishi Electric’s Flash Injection Technology
Zubadan Inverter The ZUBADAN Series incorporates Flash Injection Technology that improves the already high heating capacity of the system. This newest member of the Mr Slim range ensures comfortable heat pump-driven heating performance in colder regions.
A Heat Interchanger ( HIC )
Improved Heating Performance
Enhanced Comfort
Mitsubishi Electric’s unique “Flash Injection Circuit” achieves a remarkably high heating performance.
The Flash Injection Circuit improves start-up and recovery from defrost operation. A newly introduced defrost operation control also improves defrost frequency. These features enable the temperature to reach the set temperature more quickly and contribute to maintaining it at the desired setting.
This technology has resulted in an excellent heating capacity rating in outdoor temperatures as low as -15°C and the guaranteed heating operation range of the heating mode has been extended to -25°C. Accordingly, the Zubadan inverters are perfect for warming homes in the coldest of regions.
Flash Injection Circuit
The Key to High Heating Performance at Low Outdoor Temperatures The Zubadan Series is equipped with Mitsubishi Electric’s original Flash Injection Circuit, which is comprised of a bypass circuit and heat interchanger (HIC). The HIC transforms re-routed liquid refrigerant into a gas-liquid state to lower compression load. This process ensures excellent heating performance even when the outdoor temperature drops very low.
B Injection Compressor
In traditional units, when the outdoor temperature is low, the volume of refrigerant circulating in the compressor decreases due to the drop in refrigerant pressure and high compression (to protect from overheating), thereby reducing heating capacity. The Flash Injection Circuit injects refrigerant to maintain the refrigerant circulation volume and compressor operation load, thereby maintaining heating capacity.
Injection compressor (injection port)
Indoor HEX
Power receiver
B LEV A
LEV B LEV C
Refrigerant flow
A
Heat Interchanger (HIC)
B
Refrigerant doesn’t pass through LEV C
A
Heat interchanger (HIC)
Flash Injection Circuit
Injection Compressor Injection port
HIC cross-sectional view Refrigerant passes through LEV C (refrigerant pressure lowered)
Outdoor HEX
Refrigerant flow
Discharge port Suction port Normal refrigerant flow
ZUBADAN Defrost Control and Faster Recovery from Defrost Operation ■ Operation data for 25 Jan. 2005
■ Operation data for 2 Dec. 2004
60 °C
60°C
50 °C
50°C
40 °C
40°C
30 °C
30°C
20 °C
20°C
10 °C
10°C
0 °C
18:00
-10 °C -20 °C
20:00
22:00
0:00
2:00
4:00
6:00
0°C -10°C 8:00
10:00
12:00
14:00
16:00
18:00
20:00
22:00
-30 °C
Installation example
Field test results: Office building in Ashikawa, Hokkaido, Japan
Page 70
Purpose: Transform liquid refrigerant into liquid-gas state Effect: Injection circuit increases energy efficiency
The compressor is subjected to a heavy load when compressing liquid refrigerant, the result being lower operation efficiency. The addition of HIC supports refrigerant heat exchange at two different pressure levels. The heat-exchange process transforms the injected liquid refrigerant into a gas liquid state, thereby decreasing the load on the compressor during the compression process.
Purpose: To increase the volume of refrigerant being circulated Effect:
Improves heating capacity at low outdoor temperatures and enables higher indoor-air outlet temperature adjustment and higher defrost operation speed
Refrigerant passes from the HIC into the compressor through the injection port. Having two refrigerant inlets makes it possible to raise the volume of refrigerant being circulated when the outdoor temperature is low and at the start of heating operation.
Page 71
PLA-RP 4-Way Blow Cassette The PLA-RP-BA(2)(3) (PLFY-P-VBM-E for City Multi) 4-Way Blow Cassette, offers a range of new features, as well as a new design and pure white colour.
Wide Airflow
I New product
I Previous product
The wide shape vane (capable of wide angle air supply) provides comfort at the corners of a room, regardless of cooling or heating operation. A reduction in the air speed by 20% (compared to the previous product) eliminates the uncomfortable draft sensation often experienced.
Reduced Draft Air Distribution Reduced draft air distribution allows the vanes to supply airflow horizontally, thus preventing discomfort due to excessive cooling or from direct exposure of occupants to the air blow.
Independent Vane Control If the airflow direction needs to be changed as a result of an altered room layout or due to the mode selected (i.e. cooling or heating), the air direction of each vane can be set independently using the PAR-30MAA wired remote controller.
Reduced Draft Air Distribution
Horizontal blow PAR-30MAA Adjustable
Fixed
Down blow
Automatic Airflow Adjustment Mode The automatic airflow adjustment mode is provided in addition to the 4 normal airflow stages and allows automatic adjustment of the airflow in accordance with the difference between the set temperature and the room temperature.
Grille with Automatic Filter Lowering Function (Optional) This grille can be operated by both the wired remote controller and the exclusive infra-red remote controller. It can be lowered in 8 steps down to 4m in accordance with the ceiling height, enabling you to easily clean the air filter. Regular cleaning of the filter is an important factor in saving energy.
Automatic lowering to
4m
For example: The automatic airflow adjustment mode allows quick cooling of a room using high mode, then when the room temperature has stabilised, the low mode will be applied to maximise comfort. Low
Page 72
Medium 1
Medium 2
High
Automatic airflow adjustment
Elevation Grille Remote Controller (comes with the grille)
PAR-30MAA Wired Remote Controller
Page 73
PLA-RP 4-Way Blow Cassette
“Sensible Temperature Control” to Prevent Excessive Cooling and Heating
The (optional corner panel) Provides Even Temperature Distribution and Reduces Energy Consumption
By measuring the inlet temperature and floor temperature, a temperature felt by the human body (sensible temperature) will be calculated and maintained, suppressing excessive cooling and heating.
The “I-See Sensor” uses temperature sensing technology developed by Mitsubishi Electric. In order to create a comfortable environment in shops and offices, it is essential to control the temperature near the floor where occupants and visitors gather. The “I-See Sensor” measures the infra-red rays generated from the surrounding wall and floor surfaces and converts these into temperature values.
360°
In addition, floor temperatures are also measured at distant spots, allowing optimum airflow to reach these areas.
The "I-See Sensor" rotates to measure the floor temperature
I “I-See Sensor”operation: The “I-See Sensor”rotates slowly in intervals of 5 seconds, correctly measuring the temperature of the entire floor space.
5 seconds
5 seconds
5 seconds
5 seconds
In the past...
only the inlet temperature near the ceiling was measured, tending to overlook the uneven temperature distribution near the floor. Conventional air conditioning in shops and offices only measured the temperature near to the ceiling, therefore the uneven temperature distribution between the ceiling and the floor remained unchecked.
With “I-See Sensor”... both the floor temperature and inlet temperature are measured.
The 4-Way Blow Ceiling Cassette with the “I-See Sensor” simultaneously measures the floor and inlet temperatures, providing improved comfort to occupants and increased energy savings.
As a result, the set temperature tended to be higher in order to obtain comfort at floor level. Without “I-See Sensor”. Set temperature is 23ºC (in Heating)
Inlet temperature sensor
Area measured by cassette model without "I-See Sensor"
e.g. To achieve a sensible temperature of 20ºC, the set temperature must be as high as 23ºC
Page 74
With the “I-See Sensor” plus automatic airflow adjustment mode. Set temperature is 20ºC (in Heating)
Inlet temperature sensor
360° sensing
Area measured by the cassette model equipped with "I-See Sensor"
2.7m
e.g. With the set temperature at 20ºC, a sensible temperature of 20ºC at floor level can be obtained.
37ºC
37ºC
25ºC
25ºC
13ºC
13ºC
Page 75
The Adaptable Mr Slim Range
Designed to fit anywhere Available in a variety of options, the Mr Slim range fits in wherever it’s needed. Indoor units can be four way blow cassettes, ducted, floor, wall or ceiling mounted. Up to four indoor units can then be connected to a single outdoor unit providing the ideal air conditioning solution.
Simple technology at its best
Contents 78
PKA-RP Power Inverter Heat Pump, Wall Mounted System
80
PKA-RP Standard Inverter Heat Pump, Wall Mounted System
82
PKA-RP Zubadan Inverter Heat Pump, Wall Mounted System
84
PKA-RP Power Inverter Heat Pump, High SHF Wall Mounted System
86
SEZ-KD-VAQ Inverter Heat Pump, Ceiling Concealed Ducted System
88
PEAD-RP Power Inverter Heat Pump, Ceiling Concealed Ducted System
90
PEAD-RP Standard Inverter Heat Pump, Ceiling Concealed Ducted System
92
PEAD-RP Zubadan Inverter Heat Pump, Ceiling Concealed Ducted System
94
PEA-RP-GAQ Power Inverter Heat Pump, Large Capacity Ceiling Concealed Ducted System
96
PEA-RP-GAQ Standard Inverter Heat Pump, Large Capacity Ceiling Concealed Ducted System
98
SLZ-KA-VAQ Inverter Heat Pump, 600x600 4-Way Blow Ceiling Cassette System
100
PLA-RP Power Inverter Heat Pump, 4-Way Blow Ceiling Cassette System
102
PLA-RP Standard Inverter Heat Pump, 4-Way Blow Ceiling Cassette System
104
PLA-RP Zubadan Inverter Heat Pump, 4-Way Blow Ceiling Cassette System
106
PCA-RP Power Inverter Heat Pump, Ceiling Suspended System
108
PCA-RP Standard Inverter Heat Pump, Ceiling Suspended System
110
PCA-RP-HAQ Power Inverter Heat Pump, Stainless Steel Ceiling Suspended System
112
PCA-RP-HAQ Standard Inverter Heat Pump, Stainless Steel Ceiling Suspended System
114
PSA-RP Power Inverter Heat Pump, Floor Standing System
116
PSA-RP Standard Inverter Heat Pump, Floor Standing System
118
PHV DXE Heat Pump, Air Curtain
120
PHV NT Chilled Water Heat Pump, Sensible Cooling Wall Mounted System
122
Mr Slim Multi-Split Systems Heat Pump
124
Outdoor Units
130
Air Handling Unit Controller
131
Mr Slim Accessories / Optional Extras
Many of our systems have an energy label of A, are registered on the Energy Technology List and hence qualify for 100% first year enhanced capital allowances (whole system cost and ‘reasonable’ cost of installation). For further information please go to www.eca.gov.uk
Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB. Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB. UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. UK Conditions: Winter; indoor 21˚C DB; outdoor -1˚C WB.
Page 76
Page 77
Dimensions
Wall Mounted System Flat panel, compact indoor unit design
I
Adjustable louvres for uniform air distribution
I
Internal pipe connection to wall mounted unit for easy and neat installation
Front View
>
Side View
>
295
I
INDOOR UNIT PKA-RP35-50HAL
55
688
155
Mr Slim Range
PKA-RP Power Inverter Heat Pump
5
249
898
Technical Information PKA-RP - INDOOR UNITS PKA-RP50HAL
PKA-RP60KAL
PKA-RP71KAL
PKA-RP100KAL
4.1 (1.6-5.2)
5.0 (2.5-7.3)
7.0 (2.8-8.2)
8.0 (3.5-10.2)
11.2 (4.5-14.0)
Cooling (nominal)
3.6 (1.6-4.5)
4.6 (2.3-5.6)
6.0 (2.7-6.7)
7.1 (3.3-8.1)
10.0 (4.9-11.4)
Heating (UK)
3.5 (1.35-4.4)
4.25 (2.15-6.2)
5.95 (2.4-6.95)
6.8 (3.0-8.65)
9.5 (3.85-11.9)
Cooling (UK)
3.3 (1.45-4.15)
4.25 (2.1-5.15)
5.5 (2.5-6.15)
6.55 (3.05-7.45)
9.2 (4.5-10.5)
SHF (nominal & UK)
0.81
0.72
0.86
0.78
0.73
COP / EER (nominal)
3.63 / 3.67
3.62 / 3.22
3.98 / 3.90
3.76 / 3.62
3.61 / 3.45
A /A
A /A
A /A
A /A
A /A
ENERGy LABEL
Heating/Cooling
AIRFLOW (m3/min)
Lo-Mi-Hi
9-10.5-12
9-10.5-12
18-20-22
18-20-22
20-23-26
PIPE SIZE mm(in)
Gas
12.7 (1/2”)
12.7 (1/2”)
15.88 (5/8”)
15.88 (5/8”)
15.88 (5/8”)
Liquid
6.35 (1/4”)
6.35 (1/4”)
9.52 (3/8”)
9.52 (3/8”)
9.52 (3/8”)
36-40-43
36-40-43
39-42-45
39-42-45
41-45-49
NOISE (dBA)
Lo-Mi-Hi
DIMENSIONS (mm)
Width
898
898
1170
1170
1170
Depth
249
249
295
295
295
Height
295
295
365
365
365
13
13
21
21
21
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
Single
Single
Single
Single
Single
FUSE RATING (BS88) – HRC (A)
6
6
6
6
6
INTERCONNECTING CABLE No. CORES
4
4
4
4
4
PUHZ-RP35VHA4
PUHZ-RP50VHA4
PUHZ-RP60VHA4
PUHZ-RP71VHA4
PUHZ-RP100VKA/YKA
46 / 44 (41)
46 / 44 (41)
48 / 47 (44)
48 / 47 (44)
51 / 49 (46) 116 / 124
WEIGHT (kg) ELECTRICAL SUPPLy PHASE
INDOOR UNIT PKA-RP60-100KAL
Front View
>
Side View
> PKA-RP Power Inverter Heat Pump
PKA-RP35HAL Heating (nominal)
CAPACITy (kW)
365
MODEL REFERENCE
PUHZ-RP - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)
Heating/Cooling (silent)
WEIGHT (kg) DIMENSIONS (mm)
42
42
67
67
Width
800
800
950
950
1050
Depth
300 + 23
300 + 23
330 + 30
330 + 30
330 + 30
Height ELECTRICAL SUPPLy PHASE SySTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SySTEM RUNNING CURRENT (A) Single Phase Heating/Cooling
[MAX]
3 Phase
600
600
943
943
1338
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz / 380-415v,50Hz
Single
Single
Single
Single
Single / 3
1.13 / 0.98
1.38 / 1.43
1.76 / 1.54
2.13 / 1.96
3.10 / 2.90
1.01 / 0.83
1.23 / 1.22
1.57 / 1.31
1.90 / 1.67
2.76 / 2.47
5
5
5
5
5
5.33 / 4.66 [13.4]
6.45 / 6.68 [13.4]
8.09 / 7.11 [19.4]
9.75 / 8.99 [19.4]
14.15 / 13.25 [27.1]
-
-
-
-
5.32 / 5.01 [8.6]
FUSE RATING (BS88) - HRC (A)
16
16
20
20
32 / 10
MAINS CABLE No. Cores
3
3
3
3
3/5
MAX PIPE LENGTH (m)
50
50
50
50
75
MAX HEIGHT DIFFERENCE (m)
30
30
30
30
30
CHARGE R410A (kg) - 30m
2.5
2.5
3.5
3.5
5.0
Page 78
74
(855)
241
295
5
1170
Page 79
Wall Mounted System
Dimensions
INDOOR UNIT PKA-RP100KAL
The Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the Power Inverter range. I
Flat panel, compact indoor unit design
I
Adjustable louvres for uniform air distribution
I
Internal pipe connection to wall mounted unit for easy and neat installation
I
3-phase Standard Inverters now available
>
Side View
>
365
Front View
74
(855)
241
295
Mr Slim Range
PKA-RP Standard Inverter Heat Pump
5
1170
Technical Information PKA-RP - INDOOR UNITS MODEL REFERENCE CAPACITy (kW)
PKA-RP100KAL Heating (nominal) Cooling (nominal)
11.2 (4.5-12.5) 9.4 (4.9-11.2)
Heating (UK)
9.5 (3.85-10.65)
Cooling (UK)
8.65 (4.5-10.3)
SHF (nominal & UK)
0.75
COP / EER (nominal)
3.21 / 3.01
ENERGy LABEL
Heating/Cooling
AIRFLOW (m3/min)
Lo-Mi-Hi
PIPE SIZE mm(in)
Gas
15.88 (5/8”)
Liquid
9.52 (3/8”)
C/B 20-23-26
NOISE (dBA)
Lo-Mi-Hi
DIMENSIONS (mm)
Width
1170
Depth
295
Height
365
WEIGHT (kg)
41-45-49
21
ELECTRICAL SUPPLy PHASE
PKA-RP Standard Inverter Heat Pump
Fed by Outdoor Unit Single
FUSE RATING (BS88) - HRC (A)
6
INTERCONNECTING CABLE No. CORES
4
PUHZ-P - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)
PUHZ-P100VHA3/YHA Heating/Cooling (silent)
WEIGHT (kg)
54 / 50 (47) 75 / 77
DIMENSIONS (mm)
Width
950
Depth
330 + 30
Height ELECTRICAL SUPPLy
943 220-240v, 50Hz / 380-415v, 50Hz
PHASE
Single / 3
SySTEM POWER INPUT (kW)
Heating/Cooling (nominal)
3.49 / 3.12
Heating/Cooling (UK)
3.11 / 2.65
STARTING CURRENT (A)
8/3
SySTEM RUNNING CURRENT (A)
Single Phase
Heating/Cooling
3 Phase
[MAX]
FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m)
14.81 / 14.15 [28.6] 5.65 / 5.06 [13.6] 32 / 16 3/5 50
MAX HEIGHT DIFFERENCE (m)
30
CHARGE R410A (kg) - 20m
3.0
Page 80
Page 81
Wall Mounted System
Dimensions
INDOOR UNIT PKA-RP100KAL
Zubadan sets a new standard in performance The Mr Slim Zubadan Inverter heat pumps achieve an excellent heating performance even when the outdoor air temperature is as low as -25ºC. Flat panel, compact indoor unit design
I
Stable Heating Performance - Full heating capacity at -15°C, a 30% capacity improvement over the next size up Power Inverter
I
Expanded Heating Operation - Will work effectively even when the outdoor ambient air temperature is -25°C
I
Stable Operation - Utilising the new Flash Injection Circuit the Zubadan models have reduced defrost times and can provide continuous heating for up to 150 mins
I
Front View
>
Side View
>
365
I
74
(855)
241
295
Mr Slim Range
PKA-RP Zubadan Inver ter Heat Pump
5
1170
Quick Start-Up - At -20ºC, full heating capacity is achieved in about 20 mins, improving comfort levels
Technical Information PKA-RP - INDOOR UNITS MODEL REFERENCE CAPACITy (kW)
PKA-RP100KAL Heating (nominal) Cooling (nominal)
11.2 (4.5-14.0) 10.0 (4.9-11.4)
Heating (UK)
11.1 (4.45-13.85)
Cooling (UK)
9.2 (4.5-10.5)
SHF (nominal & UK)
0.73
COP / EER (nominal)
3.61 / 3.41
ENERGy LABEL
Heating/Cooling
AIRFLOW (m3/min)
Lo-Mi-Hi
PIPE SIZE mm(in)
Gas
15.88 (5/8”)
Liquid
9.52 (3/8”)
A /A 20-23-26
NOISE (dBA)
Lo-Mi-Hi
DIMENSIONS (mm)
Width
1170
Depth
295
Height
365
WEIGHT (kg)
41-45-49
PKA-RP Zubadan Inverter Heat Pump
21
ELECTRICAL SUPPLy
Fed by Outdoor Unit
PHASE
Single
FUSE RATING (BS88) – HRC (A)
6
INTERCONNECTING CABLE No. CORES
4
PUHZ-HRP - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)
PUHZ-HRP100VHA2/YHA2 Heating/Cooling (silent)
WEIGHT (kg)
52 / 51 (48) 120 / 134
DIMENSIONS (mm)
Width
950
Depth
330 + 30
Height ELECTRICAL SUPPLy
1350 220-240v, 50Hz / 380-415v, 50Hz
PHASE
Single / 3
SySTEM POWER INPUT (kW)
Heating/Cooling (nominal)
3.10 / 2.93
Heating/Cooling (UK)
4.50 / 2.49
STARTING CURRENT (A)
14 / 3
SySTEM RUNNING CURRENT (A)
Single Phase
Heating/Cooling
3 Phase
[MAX]
FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m)
14.15 / 13.39 [35.6] 5.32 / 5.06 [13.6] 40 / 16 3/5 75
MAX HEIGHT DIFFERENCE (m)
30
CHARGE R410A (kg) - 30m
5.5
Page 82
Page 83
High SHF Wall Mounted System
Dimensions
INDOOR UNIT PKA-RP100KAL
This new connection provides a low cost split system solution to high sensible applications such as server rooms and laboratories. High SHF system for use in server rooms and laboratories Flat panel, compact indoor unit design Adjustable louvres for uniform air distribution Internal pipe connection to wall mounted unit for easy and neat installation Duty Standby Operation available using multiple outdoor units (via PAR-30MAA) Able to connect to Run Standby Panel PANEL_RS_SMS (via Procon A1M). A maximum of 8 indoor units can be connected in this way, see page 306 for further information Gravity drain to rear of indoor unit for safe installation and operation
I I I I I
I
Front View
>
Side View
>
365
I
74
(855)
241
295
Mr Slim Range
PKA-RP Power Inverter Heat Pump
5
1170
Technical Information PKA-RP - INDOOR UNITS MODEL REFERENCE SHF
PKA-RP100KAL Cooling
6.0
(35ºC outdoor / 27ºC DB indoor, 47% relative humidity)
0.94
SHF
(35ºC outdoor / 24ºC DB indoor, 45% relative humidity)
0.96
EER
(35ºC outdoor / 27ºC DB indoor, 47% relative humidity)
4.29
EER
(35ºC outdoor / 24ºC DB indoor, 45% relative humidity)
3.75
ENERGy LABEL
Cooling
A
AIRFLOW (m3/min)
Lo-Mi-Hi
20-23-26
PIPE SIZE mm(in)
Gas
15.88 (5/8”)
Liquid
9.52 (3/8”)
PKA-RP Power Inverter Heat Pump (High SHF)
CAPACITy (kW)
41-45-49
NOISE (dBA)
Lo-Mi-Hi
DIMENSIONS (mm)
Width
1170
Depth
295
Height
365 21
WEIGHT (kg)
Fed by Outdoor Unit
ELECTRICAL SUPPLy
Single
PHASE FUSE RATING (BS88) - HRC (A)
6
INTERCONNECTING CABLE No. CORES
4
PUHZ-RP - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)
PUHZ-RP60VHA4 Heating/Cooling (silent)
WEIGHT (kg) DIMENSIONS (mm)
48 / 47 (44) 67
Width
950
Depth
330 + 30
Height ELECTRICAL SUPPLy PHASE
943 220-240v, 50Hz Single
SySTEM POWER INPUT (kW) Cooling
(35ºC outdoor / 27ºC DB indoor, 47% relative humidity)
1.4
Cooling
(35ºC outdoor / 24ºC DB indoor, 45% relative humidity)
1.6
STARTING CURRENT (A) MAX SySTEM RUNNING CURRENT (A) FUSE RATING (BS88) - HRC (A)
5 19.6 20
MAINS CABLE No. Cores
3
MAX PIPE LENGTH (m)
50
MAX HEIGHT DIFFERENCE (m)
30
CHARGE R410A (kg) - 20m
3.5
Page 84
Page 85
Dimensions INDOOR UNIT SEZ-KD25-71VAQ
Ceiling Concealed Ducted System
Upper View
Designed for homes, offices, restaurants or shops, the SEZ-KD-VAQ series operates at low noise levels. Its new improved low unit height and lightweight design also help to make installation easier and more convenient.
Note: Optional interfaces for M-NET connectivity (MAC-399IF) and group control, fault/run (MAC-397IF) are available. Please see accessories / optional extras section.
>
Mr Slim Range
SEZ-KD-VAQ Inverter Heat Pump
Technical Information
SEZ-KD-VAQ - INDOOR UNITS CAPACITy (kW)
SEZ-KD25VAQ
SEZ-KD35VAQ
SEZ-KD50VAQ
SEZ-KD60VAQ
SEZ-KD71VAQ
Heating (nominal)
3.0 (0.9-4.5)
4.2 (0.9-5.0)
6.4 (1.1-7.2)
7.4 (0.9-8.0)
8.1 (0.9-10.4)
Cooling (nominal)
2.5 (0.9-3.2)
3.7 (1.0-3.9)
5.1 (1.1-5.6)
5.6 (1.1-6.3)
7.1 (0.9-8.3)
Heating (UK)
2.5 (0.75-3.75)
3.5 (0.75-4.15)
5.3 (0.9-6.0)
6.15 (0.75-6.65)
6.75 (0.75-8.65)
Cooling (UK)
7.05 (0.9-8.25)
2.5 (0.9-3.15)
3.65 (1.0-3.85)
5.05 (1.1-5.55)
5.55 (1.1-6.25)
SHF (nominal & UK)
0.80
0.78
0.76
0.79
0.74
COP / EER (nominal)
3.61 / 3.33
3.72 / 3.39
3.54 / 3.11
3.51 / 3.01
3.72 / 3.01
ENERGy LABEL
Heating/Cooling
AIRFLOW (m3/min)
Lo-Mi-Hi
A /A
B/B
B/B
A/B
7-9-11
10-12.5-15
12-15-18
12-16-20
5-15-35-50
5-15-35-50
5-15-35-50
5-15-35-50
5-15-35-50
Gas
9.52 (3/8”)
9.52 (3/8”)
12.7 (1/2”)
15.88 (5/8”)
15.88 (5/8”)
Liquid
6.35 (1/4”)
6.35 (1/4”)
6.35 (1/4”)
6.35 (1/4”)
9.52 (3/8”)
23-26-30
23-28-33
30-34-37
30-34-38
30-35-40
EXTERNAL STATIC PRESSURE (Pa) PIPE SIZE mm(in)
A /A 6.0-7.0-9.0
Lo-Mi1-Mi2-Hi
NOISE (dBA) (15Pa)
Lo-Mi-Hi
DIMENSIONS (mm)
Width
790
990
990
1190
1190
Depth
700
700
700
700
700
Height
200
200
200
200
200
18
21
23
27
27
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
Single
Single
Single
Single
Single
FUSE RATING (BS88) - HRC (A)
6
6
6
6
6
INTERCONNECTING CABLE No. CORES
4
4
4
4
4
SUZ-KA25VA2
SUZ-KA35VA2
SUZ-KA50VA2
SUZ-KA60VA2
SUZ-KA71VA2
46 / 46
48 / 47
55 / 53
55 / 53
55 / 55
33
37
53
53
53
Width
800
800
840
840
840
Depth
285
285
330
330
330
Height
550
550
850
850
880
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
WEIGHT (kg) ELECTRICAL SUPPLy PHASE
Front View
Side View
>
> SEZ-KD-VAQ Inverter Heat Pump
MODEL REFERENCE
SUZ-KA-VA2 - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)
Heating/Cooling
WEIGHT (kg) DIMENSIONS (mm)
ELECTRICAL SUPPLy PHASE SySTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SySTEM RUNNING CURRENT (A) [MAX] Heating/Cooling FUSE RATING (BS88) - HRC (A)
Single
Single
Single
Single
Single
0.83 / 0.75
1.13 / 1.09
1.81 / 1.64
2.11 / 1.86
2.18 / 2.36
0.76 / 0.60
1.03 / 0.87
1.65 / 1.31
1.92 / 1.49
1.98 / 1.89
3.65
4.75
6.75
9.75
8.89
4.05 / 3.45 [8.6]
5.25 / 5.05 [9.7]
7.05 / 7.45 [16.7]
10.45 / 9.05 [16.7]
9.85 / 9.75 [17.0]
10
10
20
20
20
MAINS CABLE No. CORES
3
3
3
3
3
MAX PIPE LENGTH (m)
20
20
30
30
30
MAX HEIGHT DIFFERENCE (m)
12
12
30
30
30
CHARGE R410A (kg) - 7m
0.8
1.05
1.6
1.8
1.8
Page 86
Models
A
B
C
D
E
F
Size 25
700
752
798
660
7
600
Size 35-50
900
952
998
860
9
800
Size 60-71
1100
1152
1198
1060
11
1000
Page 87
Dimensions
Ceiling Concealed Ducted System I
Reduced height - entire range now only 250mm
I
Wider range of external static pressure settings across entire range
I
Reduced noise levels thanks to the use of a newly designed centrifugal fan as low as 23dBA
>
Front View
40
58
15
I
INDOOR UNIT PEAD-RP35-140JAQ
Drain pump included as standard 57 20
Air outlet
>
100 10
Upper View
D (Duct) 100x(E-1)=F
30
Mr Slim Range
PEAD-RP Power Inverter Heat Pump
57 643(Suspension bolt pitch)
Technical Information PEAD-RP - INDOOR UNITS MODEL REFERENCE
PEAD-RP35JAQ PEAD-RP50JAQ PEAD-RP60JAQ PEAD-RP71JAQ PEAD-RP100JAQ PEAD-RP125JAQ PEAD-RP140JAQ 7.0 (2.8-8.2)
8.0 (3.5-10.2)
11.2 (4.5-14.0)
14.0 (5.0-16.0)
5.0 (2.3-5.6)
6.0 (2.7-6.7)
7.1 (3.3-8.1)
10.0 (4.9-11.4)
12.5 (5.5-14.0)
14.0 (6.2-15.3)
Heating (UK)
3.5 (1.35-4.4)
5.1 (2.15-6.2)
5.95 (2.4-6.95)
6.8 (3.0-8.65)
9.5 (3.85-11.9)
11.9 (4.25-13.6)
13.6 (4.85-15.3)
Cooling (UK)
3.3 (1.45-4.15)
4.6 (2.1-5.15)
5.5 (2.5-6.15)
6.55 (3.05-7.45)
9.2 (4.5-10.5)
11.5 (5.05-12.9)
12.9 (5.7-14.1)
16.0 (5.7-18.0)
0.84
0.83
4.12 / 3.61
4.00 / 3.24
3.96 / 3.21
ENERGy LABEL
Heating/Cooling
AIRFLOW (m3/min)
Lo-Mi-Hi
PIPE SIZE mm(in)
Gas Liquid
EXTERNAL STATIC PRESSURE (Pa) Lo-Mi1-Mi2-Mi3-Hi
A /A
A /A
A /A
A /A
A /A
A /A
A /A
10-12-14
12-14.5-17
14.5-18-21
17.5-21-25
24-29-34
29.5-33.5-42
32-39-46
12.7 (1/2”)
12.7 (1/2”)
15.88 (5/8”)
15.88 (5/8”)
15.88 (5/8”)
15.88 (5/8”)
15.88 (5/8”)
6.35 (1/4”)
6.35 (1/4”)
9.52 (3/8”)
9.52 (3/8”)
9.52 (3/8”)
9.52 (3/8”)
9.52 (3/8”)
35-50-70-100-150
35-50-70-100-150
35-50-70-100-150
35-50-70-100-150
35-50-70-100-150
35-50-70-100-150
35-50-70-100-150
NOISE (dBA) (50Pa)
Lo-Mi-Hi
23-27-30
26-31-35
25-29-33
26-30-34
29-34-38
33-36-40
34-38-43
DIMENSIONS (mm)
Width
900
900
1100
1100
1400
1400
1600
Depth
732
732
732
732
732
732
732
Height
250
250
250
250
250
250
250
26
28
33
33
41
43
47
WEIGHT (kg)
Single
Single
Single
Single
Single
Single
Single
FUSE RATING (BS88) - HRC (A)
6
6
6
6
6
6
6
INTERCONNECTING CABLE No. CORES
4
4
4
4
4
4
4
PHASE
PUHZ-RP - OUTDOOR UNITS MODEL REFERENCE
PUHZ-RP35VHA4 PUHZ-RP50VHA4 PUHZ-RP60VHA4 PUHZ-RP71VHA4 PUHZ-RP100VKA/YKA PUHZ-RP125VKA/YKA PUHZ-RP140VKA/YKA Heating/Cooling (silent)
46 / 44 (41)
46 / 44 (41)
48 / 47 (44)
48 / 47 (44)
51 / 49 (46)
52 / 50 (47)
52 / 50 (47)
42
42
67
67
116 / 124
116 / 126
118 / 132
Width
800
800
950
950
1050
1050
1050
Depth
300 + 23
300 + 23
330 + 30
330 + 30
330 + 30
330 + 30
330 + 30
Height
600
600
943
943
1338
1338
1338
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
WEIGHT (kg) DIMENSIONS (mm)
ELECTRICAL SUPPLy PHASE SySTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SySTEM RUNNING CURRENT (A) Single Phase Heating/Cooling
[MAX]
3 Phase
D
732 700
Side View
>
238
Drain pipe Drain pump (O.D. 32)
10
136
67 356
Drain pipe (Spontaneous draining)
220-240v, 50Hz / 380-415v,50Hz 220-240v, 50Hz / 380-415v,50Hz 220-240v, 50Hz / 380-415v,50Hz
Single
Single
Single
Single
Single / 3
Single / 3
Single / 3
1.10 / 1.02
1.56 / 1.55
1.75 / 1.60
2.00 / 2.03
2.72 / 2.77
3.50 / 3.86
4.04 / 4.36
0.98 / 0.87
1.39 / 1.32
1.56 / 1.36
1.78 / 1.73
2.42 / 2.35
3.12 / 3.28
3.60 / 3.71
5
5
5
5
5
5
5
5.15 / 4.81 [14.1]
7.38 / 7.35 [14.4]
8.29 / 7.63 [20.6]
9.46 / 9.62 [21]
12.73 / 12.98 [29.2] 16.45 / 18.09 [29.3] 18.94 / 20.39 [30.8]
-
-
-
-
5.48 / 5.63 [10.7]
7.25 / 7.89 [12.3]
8.25 / 8.83 [13.8]
FUSE RATING (BS88) - HRC (A)
16
16
25
25
32 / 16
32 / 16
32 / 16
MAINS CABLE No. Cores
3
3
3
3
3/5
3/5
3/5
MAX PIPE LENGTH (m)
50
50
50
50
75
75
75
MAX HEIGHT DIFFERENCE (m)
30
30
30
30
30
30
30
CHARGE R410A (kg) - 30m
2.5
2.5
3.5
3.5
5.0
5.0
5.0
Page 88
>
32
Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit
ELECTRICAL SUPPLy
NOISE (dBA)
Rear View
217
0.82
4.00 / 3.50
122
0.83
4.00 / 3.75
33
0.83
3.85 / 3.23
23 40
0.84
3.73 / 3.53
100
0.85
COP / EER (nominal)
B(Suspension bolt pitch) C
178(Duct)
SHF (nominal & UK)
A 23
PEAD-RP Power Inverter Heat Pump
6.0 (2.5-7.3)
3.6 (1.6-4.5)
250
4.1 (1.6-5.2)
Cooling (nominal)
41
Heating (nominal)
Air inlet
CAPACITy (kW)
Model
A
B
C
D
900 954 1000 860 PEAD-RP60-71JAQ 1100 1154 1200 1060 PEAD-RP100-125JAQ 1400 1454 1500 1360 PEAD-RP140JAQ 1600 1654 1700 1560 PEAD-RP35-50JAQ
E 9 11 14 16
F
G
800 858 1000 1058 1300 1358 1500 1558
Page 89
Ceiling Concealed Ducted System
INDOOR UNIT PEAD-RP35-140JAQ
The Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the Power Inverter range. I
Reduced height - entire range now only 250mm
I
Wider range of external static pressure settings across entire range
I
Reduced noise levels thanks to the use of a newly designed centrifugal fan - as low as 23dBA
I
Drain pump included as standard
>
Front View
40
15
58
57 20
Upper View
>
Air outlet
3-phase Standard Inverters now available
D (Duct) 100x(E-1)=F
30 100 10
I
Dimensions
Mr Slim Range
PEAD-RP Standard Inverter Heat Pump
57 643(Suspension bolt pitch)
Technical Information PEAD-RP - INDOOR UNITS PEAD-RP35JAQ PEAD-RP50JAQ PEAD-RP60JAQ PEAD-RP71JAQ PEAD-RP100JAQ PEAD-RP125JAQ PEAD-RP140JAQ
13.6 (5.5-15.0)
Heating (UK)
3.4 (0.75-4.15)
4.9 (0.75-6.0)
5.8 (0.75-6.65)
6.65 (0.75-8.5)
9.5 (3.85-10.65)
11.9 (4.25-13.6)
13.6 (4.25-15.3)
Cooling (UK)
3.55 (1.0-3.85)
4.85 (1.1-5.55)
5.65 (1.1-6.25)
7.05 (0.9-8.05)
8.65 (4.5-10.3)
11.3 (5.05-12.9)
12.5 (5.05-13.8)
SHF (nominal & UK)
0.85
0.85
0.86
0.83
0.85
0.85
0.84
COP / EER (nominal)
3.69 / 3.40
3.64 / 3.22
3.61 / 3.39
3.92 / 3.38
3.61 / 3.09
3.62 / 2.91
3.61 / 3.01
ENERGy LABEL
Heating/Cooling
AIRFLOW (m3/min)
Lo-Mi-Hi
PIPE SIZE mm(in)
Gas Liquid
EXTERNAL STATIC PRESSURE (Pa) Lo-Mi1-Mi2-Mi3-Hi
A /A
A /A
A /A
A /A
A/B
A/C
A/B
10-12-14
12-14.5-17
14.5-18-21
17.5-21-25
24-29-34
29.5-35.5-42
32-39-46
9.52 (3/8”)
12.7 (1/2”)
15.88 (5/8”)
15.88 (5/8”)
15.88 (5/8”)
15.88 (5/8”)
15.88 (5/8”)
6.35 (1/4”)
6.35 (1/4”)
6.35 (1/4”)
9.52 (3/8”)
9.52 (3/8”)
9.52 (3/8”)
9.52 (3/8”)
35-50-70-100-150
35-50-70-100-150
35-50-70-100-150
35-50-70-100-150
35-50-70-100-150
35-50-70-100-150
35-50-70-100-150
NOISE (dBA) (50Pa)
Lo-Mi-Hi
23-27-30
26-31-35
25-29-33
26-30-34
29-34-38
33-36-40
34-38-43
DIMENSIONS (mm)
Width
900
900
1100
1100
1400
1400
1600
Depth
732
732
732
732
732
732
732
Height
250
250
250
250
250
250
250
26
28
33
33
41
43
47
WEIGHT (kg) ELECTRICAL SUPPLy
Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit
PHASE
Single
Single
Single
Single
Single
Single
Single
FUSE RATING (BS88) - HRC (A)
6
6
6
6
6
6
6
INTERCONNECTING CABLE No. CORES
4
4
4
4
4
4
4
SUZ-KA35VA2
SUZ-KA50VA2
SUZ-KA60VA2
48 / 47
55 / 53
55 / 53
55 / 55
54 / 50 (47)
55 / 51 (48)
56 / 52 (49)
37
53
53
53
75 / 77
99 / 101
99 / 101
Width
800
840
840
840
950
950
950
Depth
285
330
330
330
330 + 30
330 + 30
330 + 30
943
1350
1350
SUZ-KA / PUHZ-P - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)
Heating/Cooling (silent)
WEIGHT (kg) DIMENSIONS (mm)
Height ELECTRICAL SUPPLy PHASE SySTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SySTEM RUNNING CURRENT (A) Single Phase Heating/Cooling
[MAX]
3 Phase
SUZ-KA71VA2 PUHZ-P100VHA3/YHA PUHZ-P125VHA3/YHA PUHZ-P140VHA3/YHA
550
850
850
880
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
B(Suspension bolt pitch) C
Rear View
>
D
732 700
32
Side View
>
238
Drain pipe Drain pump (O.D. 32)
10
136
67 356
Drain pipe (Spontaneous draining)
220-240v, 50Hz / 380-415v, 50Hz 220-240v, 50Hz / 380-415v, 50Hz 220-240v, 50Hz / 380-415v, 50Hz
Single
Single
Single
Single
Single / 3
Single / 3
Single / 3
1.11 / 1.06
1.62 / 1.52
1.94 / 1.68
2.04 / 2.10
3.10 / 3.04
3.87 / 4.22
4.43 / 4.52
1.01 / 0.85
1.47 / 1.22
1.77 / 1.34
1.86 / 1.68
2.76 / 2.58
3.44 / 3.59
3.94 / 3.84
4.75
6.75
9.75
8.89
8/3
11 / 4
5.82 / 5.62 [10.3]
7.74 / 8.14 [17.4]
11.37 / 9.97 [17.6] 10.92 / 10.82 [18.1] 16.18 / 15.38 [30.7] 19.49 / 20.59 [30.8]
11 / 4 23.23 / 24.38 [32.3]
-
-
-
-
5.12 / 5.03 [15.7]
6.29 / 6.85 [15.8]
7.19 / 7.34 [15.8]
FUSE RATING (BS88) - HRC (A)
16
20
20
20
32 / 16
32 / 16
40 / 16
MAINS CABLE No. Cores
3
3
3
3
3/5
3/5
3/5
MAX PIPE LENGTH (m)
20
30
30
30
50
50
50
MAX HEIGHT DIFFERENCE (m)
12
30
30
30
30
30
30
1.05
1.6
1.8
1.8
3.0
4.5
4.5
CHARGE R410A (kg)
A 23
PEAD-RP Standard Inverter Heat Pump
16.0 (5.0-18.0)
12.3 (5.5-14.0)
250
14.0 (5.0-16.0)
9.4 (4.9-11.2)
217
11.2 (4.5-12.5)
7.1 (0.9-8.1)
122
8.0 (0.9-10.2)
5.7 (1.1-6.3)
33
7.0 (0.9-8.0)
4.9 (1.1-5.6)
23 40
5.9 (0.9-7.2)
3.6 (1.0-3.9)
100
4.1 (0.9-5.0)
Cooling (nominal)
178(Duct)
Heating (nominal)
Air inlet
CAPACITy (kW)
41
MODEL REFERENCE
Model
A
B
C
D
900 954 1000 860 PEAD-RP60-71JAQ 1100 1154 1200 1060 PEAD-RP100-125JAQ 1400 1454 1500 1360 PEAD-RP140JAQ 1600 1654 1700 1560 PEAD-RP35-50JAQ
E 9 11 14 16
F
G
800 858 1000 1058 1300 1358 1500 1558
Notes: All units charged to 7m (35-71), 20m (100) and 30m (125-140) pipe length.
Page 90
Page 91
Ceiling Concealed Ducted System
Dimensions
INDOOR UNIT PEAD-RP71-125JAQ
Zubadan sets a new standard in performance The Mr Slim Zubadan Inverter heat pumps achieve an excellent heating performance even when the outdoor air temperature is as low as -25ºC. I
Stable Heating Performance - Full heating capacity at -15°C, a 30% capacity improvement over the next size up Power Inverter
I
Expanded Heating Operation - Will work effectively even when the outdoor ambient air temperature is -25°C
I
Stable Operation - Utilising the new Flash Injection Circuit the Zubadan models have reduced defrost times and can provide continuous heating for up to 150 mins
40
15
58
57 20
>
Air outlet
Upper View
100
57
Quick Start-Up - At -20ºC, full heating capacity is achieved in about 20 mins, improving comfort levels
D (Duct) 100x(E-1)=F
30 10
I
>
Front View
Mr Slim Range
PEAD-RP Zubadan Inverter Heat Pump
643(Suspension bolt pitch)
Technical Information PEAD-RP - INDOOR UNITS
7.9 (3.45-10.1)
11.1 (4.45-13.85)
13.85 (4.95-15.85)
Cooling (UK)
6.55 (3.05-7.45)
9.2 (4.5-10.5)
11.5 (5.05-12.9)
SHF (nominal & UK)
0.83
0.82
0.84
COP / EER (nominal)
3.42 / 3.30
3.61 / 3.27
3.61 / 3.21
ENERGy LABEL
Heating/Cooling
B /A
A /A
A /A
AIRFLOW (m3/min)
Lo-Mi-Hi
17.5-21-25
24-29-34
29.5-33.5-42
PIPE SIZE mm(in)
Gas
15.88 (5/8”)
15.88 (5/8”)
15.88 (5/8”)
Liquid EXTERNAL STATIC PRESSURE (Pa) Lo-Mi1-Mi2-Mi3-Hi
9.52 (3/8”)
9.52 (3/8”)
9.52 (3/8”)
35-50-70-100-150
35-50-70-100-150
35-50-70-100-150
NOISE (dBA) (50Pa)
Lo-Mi-Hi
26-30-34
29-34-38
33-36-40
DIMENSIONS (mm)
Width
1100
1400
1400
Depth
732
732
732
Height
250
250
250
33
41
43
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
Single
Single
Single
FUSE RATING (BS88) - HRC (A)
6
6
6
INTERCONNECTING CABLE No. CORES
4
4
4
PUHZ-HRP71VHA2
PUHZ-HRP100VHA2/YHA2
PUHZ-HRP125YHA2
52 / 51 (48)
52 / 51 (48)
52 / 51 (48)
120
120 / 134
134
Width
950
950
950
Depth
330 + 30
330 + 30
330 + 30
Height
1350
1350
1350
220-240v, 50Hz
220-240v, 50Hz / 380-415,50Hz
380-415,50Hz
WEIGHT (kg) ELECTRICAL SUPPLy PHASE
PUHZ-HRP - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)
Heating/Cooling (silent)
WEIGHT (kg) DIMENSIONS (mm)
ELECTRICAL SUPPLy PHASE SySTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SySTEM RUNNING CURRENT (A) Single Phase Heating/Cooling
[MAX]
3 Phase
Single
Single / 3
3
2.34 / 2.15
3.10 / 3.06
3.88 / 3.89
3.39 / 1.83
4.50 / 2.60
5.63 / 3.31
14
14 / 3
3
10.99 / 10.15 [31.5]
14.43 / 14.28 [37.7]
-
-
6.07 / 6.09 [15.7]
7.84 / 7.94 [15.8]
FUSE RATING (BS88) - HRC (A)
32
40 / 16
16
MAINS CABLE No. Cores
3
3/5
5
MAX PIPE LENGTH (m)
75
75
75
MAX HEIGHT DIFFERENCE (m)
30
30
30
CHARGE R410A (kg) - 30m
5.5
5.5
5.5
Page 92
B(Suspension bolt pitch) C
Rear View
>
D
732 700
32
Side View
>
238
Drain pipe Drain pump (O.D. 32)
10
136
Model
67 356
A
Drain pipe (Spontaneous draining)
B
C
D
1100 1154 1200 1060 PEAD-RP100-125JAQ 1400 1454 1500 1360 PEAD-RP71JAQ
PEAD-RP Zubadan Inverter Heat Pump
Heating (UK)
A 23
250
12.5 (5.5-14.0)
41
14.0 (5.0-16.0)
10.0 (4.9-11.4)
217
11.2 (4.5-14.0)
7.1 (3.3-8.1)
122
8.0 (3.5-10.2)
Cooling (nominal)
33
Heating (nominal)
23 40
PEAD-RP125JAQ
100
PEAD-RP100JAQ
Air inlet
CAPACITy (kW)
PEAD-RP71JAQ
178(Duct)
MODEL REFERENCE
E 11 14
F
G
1000 1058 1300 1358
Page 93
Large Capacity Ceiling Concealed Ducted System I
Twin, triple or quadruple configurations on one outdoor unit, utilising Mr Slim indoor units
I
Static pressure of up to 150Pa
Dimensions
INDOOR UNIT PEA-RP200GAQ Front View
>
Upper View
>
Side View
>
Mr Slim Range
PEA-RP-GAQ Power Inverter Heat Pump
INDOOR UNIT PEA-RP250GAQ Front View
PEA-RP-GAQ - INDOOR UNITS MODEL REFERENCE CAPACITy (kW)
Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK)
SHF (nominal & UK) COP / EER (nominal) ENERGy LABEL AIRFLOW (m3/min) PIPE SIZE mm(in)
Heating/Cooling Lo-Hi Gas Liquid EXTERNAL STATIC PRESSURE (Pa) NOISE (dBA) Lo-Hi DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLy PHASE POWER INPUT (kW) (nominal) (UK) STARTING CURRENT (A) RUNNING CURRENT (A) [Max] FUSE RATING (BS88) – HRC (A) MAINS CABLE No. Cores INTERCONNECTING CABLE No. CORES
PEA-RP200GAQ 22.4 (9.5-25.0) 19.0 (9.0-22.4) 19.05 (8.1-21.25) 17.5 (8.3-20.6) 0.81 3.45 / 2.84 B / C 52-65 28.58 (1 1/8”) 9.52 (3/8”) 150 48-51 1400 634 400 70 380-415v, 50Hz 3 1.00 0.89 5.6 2.0 [2.4]
PEA-RP250GAQ 27.0 (12.5-31.5) 22.0 (11.2-28.0) 22.95 (10.65-26.8) 20.25 (10.3-25.75) 0.86 3.29 / 2.64 C / D 64-80 28.58 (1 1/8”) 12.7 (1/2”) 150 49-52 1600 634 400 77 380-415v, 50Hz 3 1.18 1.05 5.6 2.3 [2.8]
PEA-RP400GAQ 44.8 (18.0-50.0) 38.0 (18.0-44.8) 38.1 (15.3-42.5) 34.95 (16.55-41.2) 0.75 3.57 / 2.93 B / C 120 28.58 (1 1/8”) x2 9.52 (3/8”) x2 150 52 1947 764 595 130 380-415v, 50Hz 3 1.55 1.38 8.7 3.8 [4.6]
PEA-RP500GAQ 54.0 (25.0-63.0) 44.0 (22.4-56.0) 45.9 (21.25-53.55) 40.5 (20.6-51.5) 0.77 3.20 / 2.56 D / E 160 28.58 (1 1/8”) x2 12.7 (1/2”) x2 150 53 1947 764 595 133 380-415v, 50Hz 3 2.84 2.53 10 5.4 [6.5]
6 5 3
6 5 3
10 5 3
10 5 3
PUHZ-RP200YKA 59 / 58 (55) 135 1050 330 + 30 1338 380-415v, 50Hz 3 6.5 / 6.7 5.79 / 5.7 5 8.63 / 8.94 [19]
PUHZ-RP250YKA 59 / 58 (55) 141 1050 330 + 30 1338 380-415v, 50Hz 3 8.2 / 8.34 7.3 / 7.09 5 11.01 / 11.23 [21]
PUHZ-RP200YKA x2 59 / 58 (55) 135 1050 330 + 30 1338 380-415v, 50Hz 3 12.55 / 12.95 11.17 / 11.01 5 8.63 / 8.94 [19]
PUHZ-RP250YKA x2 59 / 58 (55) 141 1050 330 + 30 1338 380-415v, 50Hz 3 16.88 / 17.16 15.02 / 14.59 5 11.01 / 11.23 [21]
20 5 120 30 7.1
25 5 120 30 7.7
20 5 120 30 7.1
25 5 120 30 7.7
>
Upper View
>
Side View
>
Side View
>
PEA-RP-GAQ Power Inverter Heat Pump
Technical Information
INDOOR UNIT PEA-RP400-500GAQ Front View
>
PUHZ-RP-YKA - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm)
Heating/Cooling (silent) Width Depth Height
ELECTRICAL SUPPLy PHASE SySTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) RUNNING CURRENT (A) [Max] Heating/Cooling FUSE RATING (BS88) – HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 30m
Page 94
Upper View
>
Page 95
Large Capacity Ceiling Concealed Ducted System
INDOOR UNIT PEA-RP200GAQ
The Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the Power Inverter range. I
Twin, triple or quadruple configurations on one outdoor unit, utilising Mr Slim indoor units
I
Static pressure of up to 150Pa
Dimensions
Front View
>
Side View Upper View
>
>
Mr Slim Range
PEA-RP-GAQ Standard Inverter Heat Pump
INDOOR UNIT PEA-RP250GAQ Front View
PEA-RP-GAQ - INDOOR UNITS MODEL REFERENCE CAPACITy (kW)
Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK)
SHF (nominal & UK) COP / EER (nominal) ENERGy LABEL AIRFLOW (m3/min) PIPE SIZE mm(in)
Heating/Cooling Lo-Hi Gas Liquid EXTERNAL STATIC PRESSURE (Pa) NOISE (dBA) Lo-Hi DIMENSIONS (mm) Width Depth Height WEIGHT (kg) ELECTRICAL SUPPLy PHASE POWER INPUT (kW) (nominal) (UK) STARTING CURRENT (A) RUNNING CURRENT (A) [Max] FUSE RATING (BS88) – HRC (A) MAINS CABLE No. Cores INTERCONNECTING CABLE No. CORES
PEA-RP200GAQ 22.4 (9.5-25.0) 19.0 (9.0-22.4) 19.05 (8.1-21.25) 17.5 (8.3-20.6) 0.81 3.04 / 2.64
PEA-RP250GAQ 27.0 (12.5-31.5) 22.0 (11.2-28.0) 22.95 (10.65-26.8) 20.25 (10.3-25.75) 0.86 3.19 / 2.61
PEA-RP400GAQ 44.8 (19.0-50.0) 38.0 (18.0-44.8) 38.1 (16.15-42.5) 34.95 (16.55-41.2) 0.75 3.14 / 2.72
PEA-RP500GAQ 54.0 (25.0-63.0) 44.0 (22.4-56.0) 45.9 (21.25-53.55) 40.5 (20.6-51.5) 0.77 3.10 / 2.53
D / D 52-65 28.58 (1 1/8”) 9.52 (3/8”) 150 48-51 1400 634 400 70 380-415v, 50Hz 3 1.00 0.89 5.6 2.0 [2.4] 6 5 3
D / D 64-80 28.58 (1 1/8”) 12.7 (1/2”) 150 49-52 1600 634 400 77 380-415v, 50Hz 3 1.18 1.05 5.6 2.3 [2.8] 6 5 3
D / D 120 28.58 (1 1/8”) x2 9.52 (3/8”) x2 150 52 1947 764 595 130 380-415v, 50Hz 3 1.55 1.38 8.7 3.8 [4.6] 10 5 3
D / E 160 28.58 (1 1/8”) x2 12.7 (1/2”) x2 150 53 1947 764 595 133 380-415v, 50Hz 3 2.84 2.53 10 5.4 [ 6.5] 10 5 3
PUHZ-P200YHA3 59 / 59 (56) 126 950 330+30 1350 380-415v, 50Hz 3 7.36 / 7.21 6.55 / 6.13 5 9.88 / 9.47 [ 19 ]
PUHZ-P250YHA3 59 / 59 (56) 135 950 330+30 1350 380-415v, 50Hz 3 8.47 / 8.44 7.54 / 7.17 5 12.0 / 11.0 [ 21 ]
PUHZ-P200YHA3 x2 59 / 59 (56) 126 950 330+30 1350 380-415v, 50Hz 3
PUHZ-P250YHA3 x2 59 / 59 (56) 135 950 330+30 1350 380-415v, 50Hz 3 17.42 / 17.36 15.5 / 14.76 5 12.0 / 11.0 [ 21 ]
20 5 70 30 5.8
25 5 70 30 7.1
>
Upper View
Side View
>
Side View
>
>
PEA-RP-GAQ Standard Inverter Heat Pump
Technical Information
INDOOR UNIT PEA-RP400-500GAQ Front View
>
PUHZ-P-YHA3 - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm)
Heating/Cooling (silent) Width Depth Height
ELECTRICAL SUPPLy PHASE SySTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) RUNNING CURRENT (A) [Max] Heating/Cooling FUSE RATING (BS88) – HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m) MAX HEIGHT DIFFERENCE (m) CHARGE R410A (kg) - 30m
Page 96
14.27 / 13.97 12.7 / 11.88 5 9.88 / 9.47 [ 19 ] 20 5 70 per outdoor 30 5.8
Upper View
>
25 5 70 per outdoor 30 7.1
Page 97
Dimensions INDOOR UNIT SLZ-KA25-50VAQ
600x600 4-Way Blow Ceiling Cassette System The SLZ-KA-VAQ series is perfect for both residential and small business applications, as it offers inverter technology alongside quiet operation. The compact size of this unit is ideal for 600 by 600mm ceilings and with a depth of 208mm, this lightweight unit makes installation a breeze. This unit also comes complete with a long life filter that will last for approximately 2,500 hours.
Lower View
Note: Optional interfaces for M-NET connectivity (MAC-399IF) and group control, fault/run (MAC-397IF) are available. Please see accessories / optional extras section.
>
Mr Slim Range
SLZ-KA-VAQ Inverter Heat Pump
Technical Information
SLZ-KA-VAQ - INDOOR UNITS CAPACITy (kW)
SLZ-KA25VAQ
SLZ-KA35VAQ
SLZ-KA50VAQ
Heating (nominal)
3.2 (0.9-4.5)
4.0 (0.9-5.0)
5.0 (0.9-6.5)
Cooling (nominal)
2.5 (0.9-3.2)
3.5 (1.0-3.9)
4.6 (1.1-5.2)
Heating (UK)
2.65 (0.75-3.75)
3.3 (0.75-4.15)
4.15 (0.75-5.4)
Cooling (UK)
4.55 (1.1-5.15)
2.5 (0.9-3.15)
3.45 (1.0-3.85)
SHF (nominal & UK)
0.86
0.77
0.68
COP / EER (nominal)
3.76 / 3.68
3.67 / 3.37
3.23 / 3.01
ENERGy LABEL
Heating/Cooling
A /A
A /A
C/B
AIRFLOW (m3/min)
Lo-Mi-Hi
8-9-10
8-9-11
8-9-11
Gas
9.52 (3/8”)
9.52 (3/8”)
12.7 (1/2”)
Liquid
6.35 (1/4”)
6.35 (1/4”)
6.35 (1/4”)
28-31-37
29-33-38
30-34-39
DIMENSIONS (mm) (grille) Width
570 (650)
570 (650)
570 (650)
Depth
570 (650)
570 (650)
570 (650)
Height
235 (20)
235 (20)
235 (20)
17
17
17
PIPE SIZE mm(in)
NOISE (dBA)
WEIGHT (kg)
Lo-Mi-Hi
Unit Grille
ELECTRICAL SUPPLy
3
3
3
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
Single
Single
Single
FUSE RATING (BS88) - HRC (A)
6
6
6
INTERCONNECTING CABLE No. CORES
4
4
4
SLP-2AAW
SLP-2AAW
SLP-2AAW
SUZ-KA25VA2
SUZ-KA35VA2
SUZ-KA50VA2
46 / 46
48 / 47
55 / 53
33
37
53
Width
800
800
840
Depth
285
285
330
Height
550
550
850
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
PHASE
GRILLE REFERENCE
Side View
>
SLZ-KA-VAQ Inverter Heat Pump
MODEL REFERENCE
SUZ-KA-VA2 - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)
Heating/Cooling
WEIGHT (kg) DIMENSIONS (mm)
ELECTRICAL SUPPLy
Single
Single
Single
0.85 / 0.68
1.09 / 1.04
1.55 / 1.53
0.77 / 0.54
0.99 / 0.83
1.41 / 1.22
3.65
4.75
6.75
4.05 / 3.45 [8.5]
5.15 / 4.95 [9.6]
7.05 / 7.45 [16.7]
FUSE RATING (BS88) - HRC (A)
10
10
20
MAINS CABLE No. CORES
3
3
3
MAX PIPE LENGTH (m)
20
20
30
PHASE SySTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SySTEM RUNNING CURRENT (A) [MAX] Heating/Cooling
MAX HEIGHT DIFFERENCE (m)
12
12
30
CHARGE R410A (kg) - 7m
0.8
1.05
1.6
Page 98
Page 99
Dimensions
4-Way Blow Ceiling Cassette System I
Airflow controllable for ceiling heights up to 4.2m, with automatic adjustment of fan speed
I
Reduced draft air distribution, with independent vane control
I
Filter lowering operation down to 4m (optional PLP-6BAJ grille required)
I
Optional ‘I See Sensor' for energy saving and smooth temperature control throughout the room
INDOOR UNIT PLA-RP35-140BA(2)(3) Upper View
>
Lower View
>
Mr Slim Range
PLA-RP Power Inverter Heat Pump
Technical Information PLA-RP - INDOOR UNITS CAPACITy (kW)
PLA-RP35BA
PLA-RP50BA
PLA-RP60BA
PLA-RP71BA2
Heating (nominal)
4.1 (1.6-5.2)
6.0 (2.5-7.3)
7.0 (2.8-8.2)
8.0 (3.5-10.2)
PLA-RP100BA3 PLA-RP125BA2 11.2 (4.5-14.0)
14.0 (5.0-16.0)
16.0 (5.7-18.0)
Cooling (nominal)
3.6 (1.6-4.5)
5.0 (2.3-5.6)
6.0 (2.7-6.7)
7.1 (3.3-8.1)
10.0 (4.9-11.4)
12.5 (5.5-14.0)
14.0 (6.2-15.3)
Heating (UK)
3.5 (1.35-4.4)
5.1 (2.15-6.2)
5.95 (2.4-6.95)
6.8 (3.0-8.65)
9.5 (3.85-11.9)
11.9 (4.25-13.6)
13.6 (4.85-15.3)
Cooling (UK)
12.9 (5.7-14.1)
PLA-RP140BA2
3.3 (1.45-4.15)
4.6 (2.1-5.15)
5.5 (2.5-6.15)
6.55 (3.05-7.45)
9.2 (4.5-10.5)
11.5 (5.05-12.9)
SHF (nominal & UK)
0.84
0.81
0.76
0.73
0.74
0.71
0.71
COP / EER (nominal)
3.66 / 3.36
3.61 / 3.23
3.85 / 3.75
4.21 / 3.74
4.61 / 4.18
4.00 / 3.41
3.70 / 3.21
ENERGy LABEL
Heating/Cooling
A /A
A /A
A /A
A /A
A /A
A /A
A /A
AIRFLOW (m3/min)
Lo-Mi1-Mi2-Hi
11-12-13-15
12-14-16-18
12-14-16-18
14-16-18-21
20-23-26-30
22-25-28-31
24-26-29-32 15.88 (5/8”)
Gas
12.7 (1/2”)
12.7 (1/2”)
15.88 (5/8”)
15.88 (5/8”)
15.88 (5/8”)
15.88 (5/8”)
Liquid
6.35 (1/4”)
6.35 (1/4”)
9.52 (3/8”)
9.52 (3/8”)
9.52 (3/8”)
9.52 (3/8”)
9.52 (3/8”)
NOISE (dBA)
Lo-Mi1-Mi2-Hi
27-28-29-31
28-29-31-32
28-29-31-32
28-30-32-34
32-34-37-40
34-36-39-41
36-39-42-44
DIMENSIONS (mm)
Width
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
(Grille)
Depth
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
Height
258 (35)
258 (35)
258 (35)
258 (35)
298 (35)
298 (35)
298 (35)
Unit
22
22
23
23
26
27
27
Panel
6
6
6
6
6
6
PIPE SIZE mm(in)
WEIGHT (kg)
Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit
ELECTRICAL SUPPLy
6 Fed by Outdoor Unit
Single
Single
Single
Single
Single
Single
Single
FUSE RATING (BS88) - HRC (A)
6
6
6
6
6
6
6
INTERCONNECTING CABLE No. CORES
4
4
4
4
4
4
4
PLP-6BA
PLP-6BA
PLP-6BA
PLP-6BA
PLP-6BA
PLP-6BA
PLP-6BA
PAR-21MAA
PAR-21MAA
PAR-21MAA
PAR-21MAA
PAR-21MAA
PAR-21MAA
PAR-21MAA
PHASE
GRILLE REFERENCE WIRED REMOTE CONTROLLER REFERENCE
Side View
PUHZ-RP - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)
PUHZ-RP35VHA4
PUHZ-RP50VHA4
46 / 44 (41)
46 / 44 (41)
48 / 47 (44)
48 / 47 (44)
51 / 49 (46)
52 / 50 (47)
52 / 50 (47)
42
42
67
67
116 / 124
116 / 126
118 / 132
Width
800
800
950
950
1050
1050
1050
Depth
300 + 23
300 + 23
330 + 30
330 + 30
330 + 30
330 + 30
330 + 30
1338
1338
1338
Heating/Cooling (silent)
WEIGHT (kg) DIMENSIONS (mm)
Height ELECTRICAL SUPPLy PHASE SySTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SySTEM RUNNING CURRENT (A) Single Phase Heating/Cooling
[MAX]
3 Phase
FUSE RATING (BS88) - HRC (A)
>
PUHZ-RP60VHA4 PUHZ-RP71VHA4 PUHZ-RP100VKA/YKA PUHZ-RP125VKA/YKA PUHZ-RP140VKA/YKA
600
600
943
943
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz /380-415v,50Hz 220-240v, 50Hz/380-415v,50Hz 220-240v, 50Hz / 380-415v,50Hz
Single
Single
Single
Single
Single / 3
Single / 3
Single / 3
1.12 / 1.07
1.66 / 1.55
1.82 / 1.60
1.90 / 1.90
2.43 / 2.39
3.50 / 3.67
4.32 / 4.36
1.00 / 0.91
1.48 / 1.32
1.62 / 1.36
1.69 / 1.62
2.16 / 2.03
3.12 / 3.12
3.84 / 3.71
5
5
5
5
5
5
5.15 / 4.98 [13.2]
7.62 / 7.08 [13.4]
8.34 / 7.31 [19.4]
5
8.76 / 8.71 [19.5] 11.26 / 11.04 [27.5] 16.02 / 16.73 [27.5]
19.76 / 19.90 [29.1]
-
-
-
-
4.59 / 4.51 [9]
6.26 / 6.51 [10.5]
7.61 / 7.66 [12.1]
16
16
20
20
32 / 10
32 / 16
32 / 16
MAINS CABLE No. Cores
3
3
3
3
3/5
3/5
3/5
MAX PIPE LENGTH (m)
50
50
50
50
75
75
75
MAX HEIGHT DIFFERENCE (m)
30
30
30
30
30
30
30
CHARGE R410A (kg) - 30m
2.5
2.5
3.5
3.5
5.0
5.0
5.0
Page 100
PLA-RP Power Inverter Heat Pump
MODEL REFERENCE
Models
A
B
Size 35-71
241
258
Size 100-140
281
298
Page 101
Dimensions
4-Way Blow Ceiling Cassette System
INDOOR UNIT PLA-RP35-140BA(2)
The new Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the Power Inverter range. I
Airflow controllable for ceiling heights up to 4.2m, with automatic adjustment of fan speed
I
Reduced draft air distribution, with independent vane control
I
Filter lowering operation down to 4m (optional PLP-6BAJ grille required)
I
Optional ‘I See Sensor’ for energy saving and smooth temperature control throughout the room
I
3-phase Standard Inverters now available
Upper View
>
Lower View
>
Mr Slim Range
PLA-RP Standard Inverter Heat Pump
Technical Information PLA-RP - INDOOR UNITS MODEL REFERENCE
PLA-RP35BA
PLA-RP50BA
PLA-RP60BA
PLA-RP71BA
PLA-RP100BA
PLA-RP125BA
PLA-RP140BA2
Heating (nominal)
4.1 (0.9-5.0)
6.0 (0.9-7.2)
6.9 (0.9-8.0)
8.0 (0.9-10.2)
11.2 (4.5-12.5)
14.0 (5.0-16.0)
16.0 (5.0-18.0)
Cooling (nominal)
3.6 (1.0-3.9)
5.5 (1.1-5.6)
6.1 (1.1-6.3)
7.1 (0.9-8.1)
9.4 (4.9-11.2)
12.3 (5.5-14.0)
13.6 (5.5-15.0)
Heating (UK)
3.4 (0.75-4.15)
5.0 (0.75-6.0)
5.75 (0.75-6.65)
6.65 (0.75-8.5)
9.5 (3.85-10.65)
11.9 (4.25-13.6)
13.6 (4.25-15.3)
Cooling (UK)
3.55 (1.0-3.85)
5.45 (1.1-5.55)
6.05 (1.1-6.25)
7.05 (0.9-8.05)
8.65 (4.5-10.3)
11.3 (5.05-12.9)
12.5 (5.05-13.8)
SHF (nominal & UK)
0.84
0.81
0.76
0.73
0.74
0.71
0.71
COP / EER (nominal)
3.94 / 3.30
3.66 / 3.22
3.50 / 3.26
3.65 / 3.43
3.41 / 3.01
3.41 / 3.01
3.21 / 2.61
ENERGy LABEL
Heating/Cooling
A /A
A /A
B /A
A /A
B/B
B/B
C/D
AIRFLOW (m3/min)
Lo-Mi1-Mi2-Hi
11-12-13-15
12-14-16-18
12-14-16-18
14-16-18-21
20-23-26-30
22-25-28-31
24-26-29-32 15.88 (5/8”)
Gas
9.52 (3/8”)
12.7 (1/2”)
15.88 (5/8”)
15.88 (5/8”)
15.88 (5/8”)
15.88 (5/8”)
Liquid
6.35 (1/4”)
6.35 (1/4”)
6.35 (1/4”)
9.52 (3/8”)
9.52 (3/8”)
9.52 (3/8”)
9.52 (3/8”)
NOISE (dBA)
Lo-Mi1-Mi2-Hi
27-28-29-31
28-29-31-32
28-29-31-32
28-30-32-34
32-34-37-40
34-36-39-41
36-39-42-44
DIMENSIONS (mm)
Width
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
(Grille)
Depth
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
Height
258 (35)
258 (35)
258 (35)
258 (35)
298 (35)
298 (35)
298 (35)
Unit
22
22
23
23
25
25
27
Panel
6
6
6
6
6
6
6
PIPE SIZE mm(in)
WEIGHT (kg)
Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit
ELECTRICAL SUPPLy
Single
Single
Single
Single
Single
Single
Single
FUSE RATING (BS88) - HRC (A)
6
6
6
6
6
6
6
INTERCONNECTING CABLE No. CORES
4
4
4
4
4
4
4
PLP-6BA
PLP-6BA
PLP-6BA
PLP-6BA
PLP-6BA
PLP-6BA
PLP-6BA
PAR-21MAA
PAR-21MAA
PAR-21MAA
PAR-21MAA
PAR-21MAA
PAR-21MAA
PAR-21MAA
PHASE
GRILLE REFERENCE WIRED REMOTE CONTROLLER REFERENCE
Side View
SUZ-KA / PUHZ-P - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)
SUZ-KA35VA2
SUZ-KA50VA2
SUZ-KA60VA2
48 / 47
55 / 53
55 / 53
55 / 55
54 / 50 (47)
55 / 51 (48)
56 / 52 (49)
37
53
53
53
75 / 77
99 / 101
99 / 101
Width
800
840
840
840
950
950
950
Depth
285
330
330
330
330 + 30
330 + 30
330 + 30
943
1350
1350
Heating/Cooling (silent)
WEIGHT (kg) DIMENSIONS (mm)
Height ELECTRICAL SUPPLy PHASE SySTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SySTEM RUNNING CURRENT (A) Single Phase Heating/Cooling
[MAX]
3 Phase
FUSE RATING (BS88) - HRC (A)
550
850
850
880
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz /380-415v,50Hz 220-240v, 50Hz /380-415v,50Hz 220-240v, 50Hz /380-415v,50Hz
Single
Single
Single
Single
Single / 3
Single / 3
Single / 3
1.04 / 1.09
1.64 / 1.71
1.97 / 1.87
2.19 / 2.07
3.28 / 3.12
4.11 / 4.09
4.98 / 5.21
0.95 / 0.87
1.49 / 1.37
1.79 / 1.50
1.99 / 1.66
2.92 / 2.65
3.66 / 3.48
4.43 / 4.43
4.75
6.75
9.75
8.89
8/3
11 / 4
4.97 / 4.77 [9.4]
6.71 / 7.11 [16.4]
10.11 / 8.71 [16.4]
11 / 4
9.46 / 9.36 [16.6] 14.92 / 14.16 [28.9] 18.23 / 18.48 [29]
22.50 / 23.71 [30.6]
-
-
-
-
5.34 / 5.09 [13.9]
6.54 / 6.51 [14]
7.91 / 8.28 [14.1]
10
20
20
20
32 / 16
32 / 16
32 / 16
3
3
3
3
3/5
3/5
3/5
MAX PIPE LENGTH (m)
20
30
30
30
50
50
50
CHARGE R410A (kg)
>
SUZ-KA71VA2 PUHZ-P100VHA3/YHA PUHZ-P125VHA3/YHA PUHZ-P140VHA3/YHA
MAINS CABLE No. Cores MAX HEIGHT DIFFERENCE (m)
PLA-RP Standard Inverter Heat Pump
CAPACITy (kW)
12
30
30
30
30
30
30
1.05
1.6
1.8
1.8
3.0
4.5
4.5
Models
A
B
Size 35-71
241
258
Size 100-140
281
298
Notes: All units charged to 7m (35-71), 20m (100) and 30m (125-140) pipe length.
Page 102
Page 103
4-Way Blow Ceiling Cassette System
Dimensions
INDOOR UNIT PLA-RP71-125BA(2)(3)
Zubadan sets a new standard in performance The Mr Slim Zubadan Inverter heat pumps achieve an excellent heating performance even when the outdoor air temperature is as low as -25ºC. I
Stable Heating Performance - Full heating capacity at -15°C, a 30% capacity improvement over the next size up Power Inverter
I
Expanded Heating Operation - Will work effectively even when the outdoor ambient air temperature is -25°C
I
Stable Operation - Utilising the new Flash Injection Circuit the Zubadan models have reduced defrost times and can provide continuous heating for up to 150 mins
I
Quick Start-Up - At -20ºC, full heating capacity is achieved in about 20 mins, improving comfort levels
Upper View
>
Lower View
>
Mr Slim Range
PLA-RP Zubadan Inver ter Heat Pump
Technical Information MODEL REFERENCE CAPACITy (kW)
PLA-RP71BA2
PLA-RP100BA3
PLA-RP125BA2
Heating (nominal)
8.0 (4.5-10.2)
11.2 (4.5-14.0)
14.0 (5.0-16.0)
Cooling (nominal)
7.1 (4.9-8.1)
10.0 (4.9-11.4)
12.5 (5.5-14.0)
Heating (UK)
7.9 (4.45-10.1)
11.1 (4.45-13.85)
13.85 (4.95-15.85)
Cooling (UK)
6.55 (4.5-7.45)
9.2 (4.5-10.5)
11.5 (5.05-12.9)
0.73
0.74
0.71
4.21 / 3.66
4.41 / 4.10 [4.31 / 4.00]
3.92 / 3.30
SHF (nominal & UK) COP / EER (nominal)
[3 Phase]
ENERGy LABEL
Heating/Cooling
A /A
A /A
A /A
AIRFLOW (m3/min)
Lo-Mi1-Mi2-Hi
14-16-18-21
20-23-26-30
22-25-28-31 15.88 (5/8”)
Gas
15.88 (5/8”)
15.88 (5/8”)
Liquid
9.52 (3/8”)
9.52 (3/8”)
9.52 (3/8”)
NOISE (dBA)
Lo-Mi1-Mi2-Hi
28-30-32-34
32-34-37-40
34-36-39-41
DIMENSIONS (mm)
Width
840 (950)
840 (950)
840 (950)
(Grille)
Depth
840 (950)
840 (950)
840 (950)
Height
258 (35)
298 (35)
298 (35)
Unit
23
26
27
Panel
6
6
6
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
PIPE SIZE mm(in)
WEIGHT (kg) ELECTRICAL SUPPLy
Single
Single
Single
FUSE RATING (BS88) - HRC (A)
6
6
6
INTERCONNECTING CABLE No. CORES
4
4
4
PLP-6BA
PLP-6BA
PLP-6BA
PAR-21MAA
PAR-21MAA
PAR-21MAA
PHASE
GRILLE REFERENCE WIRED REMOTE CONTROLLER REFERENCE
Side View
PUHZ-HRP - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)
PUHZ-HRP71VHA2
PUHZ-HRP100VHA2/YHA2
PUHZ-HRP125YHA2
52 / 51 (48)
52 / 51 (48)
52 / 51 (48)
120
120 / 134
134
Width
950
950
950
Depth
330 + 30
330 + 30
330 + 30
Heating/Cooling (silent)
WEIGHT (kg) DIMENSIONS (mm)
Height ELECTRICAL SUPPLy PHASE
1350
1350
1350
220-240v, 50Hz
220-240v, 50Hz / 380-415,50Hz
380-415,50Hz
Single
Single / 3
3
SySTEM POWER INPUT (kW) Heating/Cooling (nominal)
1.90 / 1.94
2.54 / 2.44 [2.60 / 2.50]
3.57 / 3.79
[3 Phase]
2.76 / 1.65
3.68 / 2.07 [3.77 / 2.13]
5.18 / 3.22
14
14 / 3
3
8.76 / 8.89 [30]
11.76 / 11.26 [36]
-
Heating/Cooling (UK)
STARTING CURRENT (A) SySTEM RUNNING CURRENT (A) Single Phase Heating/Cooling
[MAX]
3 Phase
-
4.86 / 4.69 [14]
6.37 / 6.70 [14]
32
40 / 16
16
MAINS CABLE No. Cores
3
3/5
5
MAX PIPE LENGTH (m)
75
75
75
FUSE RATING (BS88) - HRC (A)
MAX HEIGHT DIFFERENCE (m)
30
30
30
CHARGE R410A (kg) - 30m
5.5
5.5
5.5
Page 104
PLA-RP Zubadan Inverter Heat Pump
PLA-RP - INDOOR UNITS
>
Models
A
B
Size 71
241
258
Size 100-125
281
298
Page 105
Dimensions
Ceiling Suspended System
PCA-RP50KAQ 51 853
Side View
5
>
254
476
680
57
Lower View
>
236
Flush to wall installation for concealment of service connections
>
10
230
I
Front View
2
195
Indoor unit designed for direct ceiling suspension
960
84 88
I
2
Mr Slim Range
PCA-RP Power Inverter Heat Pump
182
85
878
Technical Information
PCA-RP60-71KAQ 51
5.5 (2.5-6.6)
7.0 (2.8-8.2)
8.0 (3.5-10.2)
11.2 (4.5-14.0)
14.0 (5.0-16.0)
16.0 (5.7-18.0)
Cooling (nominal)
5.0 (2.3-5.6)
6.0 (2.7-6.7)
7.1 (3.3-8.1)
10.0 (4.9-11.4)
12.5 (5.5-14.0)
14.0 (6.2-15.3)
Heating (UK)
4.7 (2.15-5.6)
5.95 (2.4-6.95)
6.8 (3.0-8.65)
9.5 (3.85-11.9)
11.9 (4.25-13.6)
13.6 (4.85-15.3)
Cooling (UK)
12.9 (5.7-14.1)
4.6 (2.1-5.15)
5.5 (2.5-6.15)
6.55 (3.05-7.45)
9.2 (4.5-10.5)
11.5 (5.05-12.9)
SHF (nominal & UK)
0.79
0.81
0.76
0.77
0.72
0.71
COP / EER (nominal)
3.62 / 3.21
3.61 / 4.00
3.62 / 3.62
3.71 / 3.80
3.61 / 3.22
3.61 / 3.21
ENERGy LABEL
Heating/Cooling
A /A
A /A
A /A
A /A
A /A
A /A
AIRFLOW (m3/min)
Lo-Mi1-Mi2-Hi
10-11-13-15
15-16-17-19
16-17-18-20
22-24-26-28
23-25-27-29
24-26-29-32 15.88 (5/8”)
15.88 (5/8”)
15.88 (5/8”)
15.88 (5/8”)
15.88 (5/8”)
6.35 (1/4”)
9.52 (3/8”)
9.52 (3/8”)
9.52 (3/8”)
9.52 (3/8”)
9.52 (3/8”)
Lo-Mi1-Mi2-Hi
32-34-37-40
33-35-37-40
35-37-39-41
37-39-41-43
39-41-43-45
41-43-45-48
Width
960
1280
1280
1600
1600
1600
Depth
680
680
680
680
680
680
Height
230
230
230
230
230
230
32
32
36
38
39
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
Single
Single
Single
Single
Single
Single
FUSE RATING (BS88) - HRC (A)
6
6
6
6
6
6
INTERCONNECTING CABLE No. CORES
4
4
4
4
4
4
NOISE (dBA)
Heating/Cooling (silent)
WEIGHT (kg) DIMENSIONS (mm)
PUHZ-RP60VHA4
PUHZ-RP71VHA4
PUHZ-RP100VKA/YKA
PUHZ-RP125VKA/YKA
PUHZ-RP140VKA/YKA
46 / 44 (41)
48 / 47 (44)
48 / 47 (44)
51 / 49 (46)
52 / 50 (47)
52 / 50 (47) 118 / 132
42
67
67
116 / 124
116 / 126
800
950
950
1050
1050
1050
Depth
300 + 23
330 + 30
330 + 30
330 + 30
330 + 30
330 + 30
1338
1338
1338
Height PHASE SySTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SySTEM RUNNING CURRENT (A) Single Phase Heating/Cooling
PUHZ-RP50VHA4
Width
ELECTRICAL SUPPLy
[MAX]
3 Phase
FUSE RATING (BS88) - HRC (A)
600
943
943
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz / 380-415v,50Hz 220-240v, 50Hz / 380-415v,50Hz 220-240v, 50Hz / 380-415v,50Hz
Single
Single
Single
Single / 3
Single / 3
Single / 3
1.52 / 1.56
1.94 / 1.50
2.21 / 1.96
3.02 / 2.63
3.88 / 3.88
4.43 / 4.36
1.35 / 1.33
1.73 / 1.28
1.97 / 1.67
2.69 / 2.24
3.45 / 3.30
3.94 / 3.71
5
5
5
5
5
5
6.96 / 7.14 [13.4]
8.82 / 6.84 [19.4]
10.06 / 8.94 [19.4]
13.78 / 12.04 [27.2]
17.66 / 17.66 [27.3]
20.13 / 19.82 [28.9]
-
-
-
5.25 / 4.63 [8.7]
6.67 / 6.67 [10.3]
7.63 / 7.52 [11.9]
16
20
20
32 / 10
32 / 16
32 / 16
MAINS CABLE No. Cores
3
3
3
3/5
3/5
3/5
MAX PIPE LENGTH (m)
50
50
50
75
75
75
MAX HEIGHT DIFFERENCE (m)
30
30
30
30
30
30
CHARGE R410A (kg) - 30m
2.5
3.5
3.5
5.0
5.0
5.0
Page 106
Side View
>
85
PCA-RP100-140KAQ 51
PUHZ-RP - OUTDOOR UNITS MODEL REFERENCE
182 1198
Front View
>
2
1600 1493
2
Lower View
10 5
236
PHASE
25 Fed by Outdoor Unit
5
> 680
ELECTRICAL SUPPLy
>
>
84 88 195 230
WEIGHT (kg)
Lower View
Side View
57
DIMENSIONS (mm)
12.7 (1/2”)
5
476
NOISE (dBA)
Gas Liquid
1173
254
PIPE SIZE mm(in)
>
182
85
1518
Page 107
PCA-RP Power Inverter Heat Pump
Heating (nominal)
Front View
236
PCA-RP140KAQ
230
PCA-RP125KAQ
680
PCA-RP100KAQ
195
PCA-RP71KAQ
10
57
PCA-RP60KAQ
1
476
CAPACITy (kW)
PCA-RP50KAQ
2
84 88
MODEL REFERENCE
1280
2
254
PCA-RP - INDOOR UNITS
Ceiling Suspended System
Dimensions
PCA-RP50KAQ 51
Indoor unit designed for direct ceiling suspension
I
Flush to wall installation for concealment of service connections
I
3-phase Standard Inverters now available
2
853
>
5
236
Side View
>
254
476
680
57
Lower View
10
230
>
960
84 88
I
Front View
2
195
The new Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the Power Inverter range.
Mr Slim Range
PCA-RP Standard Inverter Heat Pump
182
85
878
PCA-RP60-71KAQ Technical Information
6.9 (0.9-8.0)
7.9 (0.9-10.2)
11.2 (4.5-12.5)
14.0 (5.0-16.0)
16.0 (5.0-18.0)
5.0 (1.1-5.6)
5.7 (1.1-6.3)
7.1 (0.9-8.1)
9.4 (4.9-11.2)
12.3 (5.5-14.0)
13.6 (5.5-15.0)
Heating (UK)
4.55 (0.75-5.5)
5.75 (0.75-6.65)
6.55 (0.75-8.5)
9.5 (3.85-10.65)
11.9 (4.25-13.6)
13.6 (4.25-15.3)
Cooling (UK)
4.95 (1.1-5.55)
5.65 (1.1-6.25)
7.05 (0.9-8.05)
8.65 (4.5-10.3)
11.3 (5.05-12.9)
12.5 (5.05-13.8)
0.79
0.81
0.76
0.77
0.72
0.71
3.22 / 3.01
3.42 / 3.22
4.03 / 3.45
3.41 / 3.00
3.40 / 3.01
3.41 / 2.81
C/B
B /A
A /A
B/C
C/B
B/C
SHF (nominal & UK) COP / EER (nominal) ENERGy LABEL
Heating/Cooling
AIRFLOW (m3/min)
Lo-Mi1-Mi2-Hi
10-11-13-15
15-16-17-19
16-17-18-20
22-24-26-28
23-25-27-29
24-26-29-32 15.88 (5/8”)
PIPE SIZE mm(in) NOISE (dBA) DIMENSIONS (mm)
Gas
12.7 (1/2”)
15.88 (5/8”)
15.88 (5/8”)
15.88 (5/8”)
15.88 (5/8”)
Liquid
6.35 (1/4”)
6.35 (1/4”)
9.52 (3/8”)
9.52 (3/8”)
9.52 (3/8”)
9.52 (3/8”)
Lo-Mi1-Mi2-Hi
32-34-37-40
33-35-37-40
35-37-39-41
37-39-41-43
39-41-43-45
41-43-45-48
Width
960
1280
1280
1600
1600
1600
Depth
680
680
680
680
680
680
Height
230
230
230
230
230
230
25
32
32
36
38
39
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
WEIGHT (kg) ELECTRICAL SUPPLy
Single
Single
Single
Single
Single
Single
FUSE RATING (BS88) - HRC (A)
6
6
6
6
6
6
INTERCONNECTING CABLE No. CORES
4
4
4
4
4
4
PHASE
Lower View
Side View
>
>
182
85
1198
PCA-RP100-140KAQ 51
DIMENSIONS (mm)
PUHZ-P100VHA3/YHA PUHZ-P125VHA3/YHA PUHZ-P140VHA3/YHA 54 / 50 (47)
55 / 51 (48)
56 / 52 (49) 99 / 101
53
53
53
75 / 77
99 / 101
840
840
950
950
950
Depth
330
330
330
330 + 30
330 + 30
330 + 30
943
1350
1350
PHASE SySTEM POWER INPUT (kW) Heating/Cooling (nominal) Heating/Cooling (UK) STARTING CURRENT (A) SySTEM RUNNING CURRENT (A) Single Phase 3 Phase
FUSE RATING (BS88) - HRC (A)
850
850
880
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz / 380-415v,50Hz 220-240v, 50Hz / 380-415v,50Hz 220-240v, 50Hz / 380-415v,50Hz
Single
Single
Single
Single / 3
Single / 3
Single / 3
1.71 / 1.66
2.02 / 1.77
1.96 / 2.06
3.28 / 3.13
4.12 / 4.09
4.69 / 4.84
1.56 / 1.33
1.84 / 1.42
1.78 / 1.65
2.92 / 2.66
3.67 / 3.48
4.17 / 4.11
6.75
9.75
8.89
8/3
11 / 4
11 / 4
6.72 / 7.12 [16.4]
10.14 / 8.74 [16.4]
9.37 / 9.27 [16.5]
15.73 / 14.09 [28.7]
18.55 / 18.42 [28.8]
21.09 / 21.97 [30.4]
-
-
-
5.33 / 5.09 [13.7]
6.54 / 6.50 [13.8]
7.44 / 7.67 [13.9]
20
20
20
32 / 16
32 / 16
32 / 16
MAINS CABLE No. Cores
3
3
3
3/5
3/5
3/5
MAX PIPE LENGTH (m)
30
30
30
50
50
50
MAX HEIGHT DIFFERENCE (m)
30
30
30
30
30
30
CHARGE R410A (kg)
1.6
1.8
1.8
3.0
4.5
4.5
Front View
>
Lower View
236
55 / 55
840
Height
[MAX]
SUZ-KA71VA2
55 / 53
Width
ELECTRICAL SUPPLy
Heating/Cooling
SUZ-KA60VA2
55 / 53
10 5
> 680
WEIGHT (kg)
SUZ-KA50VA2
84 88 195 230
Heating/Cooling (silent)
2
57
NOISE (dBA)
1600 1493
476
MODEL REFERENCE
2
254
SUZ-KA / PUHZ-P - OUTDOOR UNITS
182
85
1518
Notes: All units charged to 7m (50-71), 20m (100) and 30m (125-140) pipe length.
Page 108
Page 109
PCA-RP Standard Inverter Heat Pump
5.5 (0.9-6.6)
Cooling (nominal)
5
236
Heating (nominal)
>
230
PCA-RP140KAQ
Side View
680
PCA-RP125KAQ
195
PCA-RP100KAQ
5
57
PCA-RP71KAQ
1173
10
476
PCA-RP60KAQ
1
254
CAPACITy (kW)
PCA-RP50KAQ
>
2
84 88
Front View
PCA-RP - INDOOR UNITS MODEL REFERENCE
51 1280
2
Stainless Steel Ceiling Suspended System
Dimensions
INDOOR UNIT PCA-RP71HAQ
High performance oil mist filter
I
Easy maintenance - fan casing can be separated into different sections allowing easy cleaning. The drain pan can also be cleaned easily on-site as the pipe connector can be quickly removed
I
1224 1180
110 102
I
>
Front View
The PCA-RP-HAQ series is a ceiling suspended unit ideal for use in kitchen environments. The external casing is made of durable stainless steel that is resistant to oil and smoke, ensuring that the unit can be easily cleaned at all times.
75
986 1136
Optional decoration covers Lower View
Mr Slim Range
PCA-RP-HAQ Power Inverter Heat Pump
> >
650
Side View
280
258
Technical Information PCA-RP-HAQ - INDOOR UNITS 13.8 (5.0-16.0)
Cooling (nominal)
7.1 (3.3-8.1)
12.5 (5.5-14.0)
Heating (UK)
6.45 (3.0-8.65)
11.75 (4.25-13.6)
Cooling (UK)
6.55 (3.05-7.45)
11.5 (5.05-12.9)
SHF (nominal & UK)
0.74
0.77
COP / EER (nominal)
3.41 / 3.21
3.41 / 3.22
ENERGy LABEL
Heating/Cooling
B /A
B /A
AIRFLOW (m3/min)
Lo-Hi
17-19
30-38
PIPE SIZE mm(in)
Gas
15.88 (5/8”)
15.88 (5/8”)
Liquid
9.52 (3/8”)
9.52 (3/8”)
NOISE (dBA)
Lo-Hi
34-38
44-50
DIMENSIONS (mm)
Width
1136
1520
Depth
650
650
Height
280
280
WEIGHT (kg) ELECTRICAL SUPPLy PHASE
41
56
Fed by Outdoor Unit
Fed by Outdoor Unit
Single
Single
FUSE RATING (BS88) - HRC (A)
6
6
INTERCONNECTING CABLE No. CORES
4
4
PUHZ-RP71VHA4
PUHZ-RP125VKA/YKA
48 / 47 (44)
52 / 50 (47)
67
116 / 126
1136
INDOOR UNIT PCA-RP125HAQ Front View
> 1608 1564
1370 1520
PUHZ-RP - OUTDOOR UNITS NOISE (dBA)
Heating/Cooling (silent)
WEIGHT (kg) DIMENSIONS (mm)
Width
950
1050
Depth
330 + 30
330 + 30
Height
943
1338
220-240v, 50Hz
220-240v, 50Hz / 380-415v, 50Hz
Single
Single / 3
Heating/Cooling (nominal)
2.23 / 2.21
4.05 / 3.88
Heating/Cooling (UK)
1.98 / 1.88
3.60 / 3.30
ELECTRICAL SUPPLy PHASE SySTEM POWER INPUT (KW) STARTING CURRENT (A) SySTEM RUNNING CURRENT (A) Single Phase Heating/Cooling
[MAX]
3 Phase
5
5
10.02 / 9.93 [19.4]
18.18 / 17.42 [27.7]
-
7.14 / 6.87 [10.7]
FUSE RATING (BS88) - HRC (A)
20
32 / 16
MAINS CABLE No. Cores
3
3/5
MAX PIPE LENGTH (m)
50
75
MAX HEIGHT DIFFERENCE (m)
30
30
CHARGE R410A (kg) - 30m
3.5
5.0
Page 110
Lower View
75
> Side View
>
650
MODEL REFERENCE
650
PCA-RP-HAQ Power Inverter Heat Pump
PCA-RP125HAQ
7.6 (3.5-10.2)
1520
280
PCA-RP71HAQ Heating (nominal)
110 102
CAPACITy (kW)
258
MODEL REFERENCE
650
Page 111
Stainless Steel Ceiling Suspended System
Dimensions
INDOOR UNIT PCA-RP125HAQ
The new Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the Power Inverter range. High performance oil mist filter
I
Easy maintenance - fan casing can be separated into different sections allowing easy cleaning. The drain pan can also be cleaned easily on-site as the pipe connector can be quickly removed
I
Optional decoration covers
I
3-phase Standard Inverters now available
> 1608 1564
110 102
I
Front View
1370 1520
Lower View
75
>
PCA-RP125HAQ Heating (nominal) Cooling (nominal)
13.8 (5.0-16.0) 12.3 (5.5-14.0)
Heating (UK)
11.75 (4.25-13.6)
Cooling (UK)
11.3 (5.05-12.9)
SHF (nominal & UK)
0.78
COP / EER (nominal)
3.21 / 2.81
ENERGy LABEL
Heating/Cooling
C/C
AIRFLOW (m3/min)
Lo-Hi
30-38
PIPE SIZE mm(in)
Gas
15.88 (5/8”)
Liquid
9.52 (3/8”)
NOISE (dBA)
Lo-Hi
44-50
DIMENSIONS (mm)
Width
1520
Depth
650
Height
280
WEIGHT (kg)
1520
650
PCA-RP-HAQ Standard Inverter Heat Pump
CAPACITy (kW)
280
258
PCA-RP-HAQ - INDOOR UNITS MODEL REFERENCE
>
650
Side View
Technical Information
56
ELECTRICAL SUPPLy
Fed by Outdoor Unit
PHASE
Single
FUSE RATING (BS88) - HRC (A)
6
INTERCONNECTING CABLE No. CORES
4
PUHZ-P - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)
PUHZ-P125VHA3/YHA Heating/Cooling (silent)
WEIGHT (kg) Width
950
Depth
330 + 30
Height ELECTRICAL SUPPLy
1350 220-240v, 50Hz / 380-415v, 50Hz
PHASE
Single / 3
SySTEM POWER INPUT (KW)
Heating/Cooling (nominal)
4.30 / 4.38
Heating/Cooling (UK)
3.83 / 3.72
STARTING CURRENT (A) SySTEM RUNNING CURRENT (A) Heating/Cooling
55 / 51 (48) 99 / 101
DIMENSIONS (mm)
[MAX]
FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores MAX PIPE LENGTH (m)
11 / 4 Single Phase 3 Phase
19.11 / 19.47 [29.2] 6.73 / 6.86 [14.2] 32 / 16 3/5 50
MAX HEIGHT DIFFERENCE (m)
30
CHARGE R410A (kg) - 30m
4.5
Page 112
Mr Slim Range
PCA-RP-HAQ Standard Inverter Heat Pump
Page 113
Dimensions
Floor Standing System
INDOOR UNIT PSA-RP71GA Front View
The PSA-RP Floor Standing System complements the Mitsubishi Electric range of indoor units. The sleek, modern design of this unit is ideal for numerous applications including bars and restaurants. I
>
Side View
>
Upper View
>
Upper View
>
Built in controller
Mr Slim Range
PSA-RP Power Inverter Heat Pump
Note: When used with a Mr Slim Multi-Split system. PSA-RP cannot be connected with indoor units of different type.
Technical Information PSA-RP - INDOOR UNITS CAPACITy (kW)
PSA-RP71GA
PSA-RP100GA
PSA-RP125GA
Heating (nominal)
7.6 (3.5-10.2)
11.2 (4.5-14.0)
14.0 (5.0-16.0)
Cooling (nominal)
7.1 (3.3-8.1)
10.0 (4.9-11.4)
12.4 (5.5-14.0)
Heating (UK)
6.45 (3.0-8.65)
9.5 (3.85-11.9)
11.9 (4.25-13.6)
Cooling (UK)
11.4 (5.05-12.9)
6.55 (3.05-7.45)
9.2 (4.5-10.5)
SHF (nominal & UK )
0.73
0.81
0.75
COP / EER (nominal)
3.41 / 3.23
3.41 / 3.34
3.41 / 3.01
ENERGy LABEL
Heating/Cooling
B /A
B /A
B/B
AIRFLOW (m3/min)
Lo-Hi
15-18
24-31
26-33
PIPE SIZE mm(in)
Gas
15.88 (5/8”)
15.88 (5/8”)
15.88 (5/8”)
Liquid
9.52 (3/8”)
9.52 (3/8”)
9.52 (3/8”)
NOISE (dBA)
Lo-Hi
40-45
44-49
46-51
DIMENSIONS (mm)
Width
600
600
600
Depth
270
350
350
Height
1900
1900
1900
WEIGHT (kg) ELECTRICAL SUPPLy
43
51
51
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
Single
Single
Single
FUSE RATING (BS88) - HRC (A)
6
6
6
INTERCONNECTING CABLE No. CORES
4
4
4
PUHZ-RP71VHA4
PUHZ-RP100VKA/YKA
PUHZ-RP125VKA/YKA
48 / 47 (44)
51 / 49 (46)
52 / 50 (47)
67
116 / 124
116 / 126
Width
950
1050
1050
Depth
330 + 30
330 + 30
330 + 30
PHASE
INDOOR UNIT PSA-RP100-125GA Front View
>
Side View
>
PSA-RP Power Inverter Heat Pump
MODEL REFERENCE
PUHZ-RP - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)
Heating/Cooling (silent)
WEIGHT (kg) DIMENSIONS (mm)
Height ELECTRICAL SUPPLy PHASE SySTEM POWER INPUT (KW)
1338
1338
220-240v, 50Hz / 380-415v, 50Hz
220-240v, 50Hz / 380-415v, 50Hz
Single
Single / 3
Single / 3
Heating/Cooling (nominal)
2.23 / 2.20
3.28 / 2.99
4.11 / 4.12
Heating/Cooling (UK)
1.98 / 1.87
2.92 / 2.54
3.66 / 3.50
5
5
5
9.98 / 9.85 [19.7]
14.69 / 13.39 [27.6]
18.40 / 18.44 [27.7]
STARTING CURRENT (A) SySTEM RUNNING CURRENT (A) Single Phase Heating/Cooling
943 220-240v, 50Hz
[MAX]
3 Phase
-
5.83 / 5.37 [9.1]
7.24 / 7.25 [10.7]
FUSE RATING (BS88) - HRC (A)
20
32 / 10
32 / 16
MAINS CABLE No. Cores
3
3 / 5
3 / 5
MAX PIPE LENGTH (m)
50
75
75
MAX HEIGHT DIFFERENCE (m)
30
30
30
CHARGE R410A (kg) - 30m
3.5
5.0
5.0
Page 114
Page 115
Floor Standing System
Dimensions
INDOOR UNIT PSA-RP100-125GA
The Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the Power Inverter range.
Front View
>
Side View
>
Upper View
>
The PSA-RP Floor Standing System complements the Mitsubishi Electric range of indoor units. The sleek, modern design of this unit is ideal for numerous applications including bars and restaurants. I
Built in controller
I
3-phase Standard Inverters now available
Mr Slim Range
PSA-RP Standard Inverter Heat Pump
Note: When used with a Mr Slim Multi-Split system. PSA-RP cannot be connected with indoor units of different type.
Technical Information MODEL REFERENCE CAPACITy (kW)
PSA-RP100GA
PSA-RP125GA
Heating (nominal)
11.2 (4.5-12.5)
14.0 (5.0-16.0)
Cooling (nominal)
9.4 (4.9-11.2)
12.3 (5.5-14.0)
Heating (UK)
9.5 (3.85-10.65)
11.9 (4.25-13.6)
Cooling (UK)
8.65 (4.5-10.3)
11.3 (5.05-12.9)
SHF (nominal & UK)
0.83
0.76
COP / EER (nominal)
3.41 / 3.01
2.81 / 2.81 D/C
ENERGy LABEL
Heating/Cooling
B/B
AIRFLOW (m3/min)
Lo-Hi
24-31
26-33
PIPE SIZE mm(in)
Gas
15.88 (5/8”)
15.88 (5/8”)
Liquid
9.52 (3/8”)
9.52 (3/8”)
NOISE (dBA)
Lo-Hi
44-49
46-51
DIMENSIONS (mm)
Width
600
600
Depth
350
350
Height
1900
1900
WEIGHT (kg) ELECTRICAL SUPPLy PHASE
51
51
Fed by Outdoor Unit
Fed by Outdoor Unit
Single
Single
FUSE RATING (BS88) - HRC (A)
6
6
INTERCONNECTING CABLE No. CORES
4
4
PSA-RP Standard Inverter Heat Pump
PSA-RP - INDOOR UNITS
PUHZ-P - OUTDOOR UNITS MODEL REFERENCE NOISE (dBA)
Heating/Cooling (silent)
WEIGHT (kg) DIMENSIONS (mm)
PUHZ-P125VHA3/YHA
54 / 50 (47)
55 / 51 (48)
75 / 77
99 / 101
Width
950
950
Depth
330 + 30
330 + 30
Height ELECTRICAL SUPPLy PHASE SySTEM POWER INPUT (KW)
PUHZ-P100VHA3/YHA
943
1350
220-240v, 50Hz / 380-415v, 50Hz
220-240v, 50Hz / 380-415v, 50Hz
Single / 3
Single / 3
Heating/Cooling (nominal)
3.28 / 3.12
4.98 / 4.38
Heating/Cooling (UK)
2.92 / 2.65
4.43 / 3.72
STARTING CURRENT (A)
8/3
11 / 4
14.55 / 13.84 [29.1]
22.08 / 19.42 [29.2]
5.23 / 4.97 [14.1]
7.78 / 6.84 [14.2]
32 / 16
32 / 16
3/5
3/5
MAX PIPE LENGTH (m)
50
50
MAX HEIGHT DIFFERENCE (m)
30
30
CHARGE R410A (kg)
3.0
4.5
SySTEM RUNNING CURRENT (A) Heating/Cooling
[MAX]
Single Phase 3 Phase
FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores
Notes: All units charged to 20m (100) and 30m (125) pipe length.
Page 116
Page 117
Dimensions
Heat Pump Air Curtain System
AIR CURTAIN PHV1000/1500/2000R DXE
In collaboration with Thermoscreens 速, Mitsubishi Electric have developed a range of air cur tains that can be connected to our Power Inver ter heat pumps, as opposed to the more traditional direct electric method associated with air cur tains. I
Reduced CO2 emissions (up to 67%)
I
Reduced Running Costs (up to 67%)
I
2.5 year payback period against equivalent Electric system
I
Inverter technology (does not waste energy)
I
Range of different sizes to suit every application
I
Allows open door policy in retail outlets whilst being energy efficient
I
Clean environment - protection from dust, fumes etc
I
Comfortable climate for customers
I
Easy to install and maintain
Side View
>
Rear View
>
Upper View
Mr Slim Range
PHV DXE Heat Pump Air Curtain
>
Technical Information PHV DXE - RECESSED MODEL REFERENCE DIMENSIONS (mm) (WxDxH) SUPPLy (50Hz)
PHV1000R DXE HO
PHV1500R DXE LO
PHV1500R DXE HO
PHV2000R DXE LO
PHV2000R DXE HO
1150x436x296
1650x436x296
1650x436x296
2240x436x296
2240x436x296
415V*1
415V*1
415V*1
415V*2
415V*2
HEAT OUTPUT (kW)
100% / 50%
8.6 / 5.34
10.1 / 5.6
14.4 / 8.3
14.1 / 7.9
21.3 / 11.2
COP
100% / 50%
2.4 / 3.15
2.3 / 3.4
2.5 / 3.7
2.9 / 3.7
2.4 / 3.2
LOADING (amps)
7.8*1
12.7*1
12.7*1
15.7*2
15.7*2
VELOCITy (m/s)
9
9
9
9.5
9
AIR VOLUME (m3/h)
1400
2500
2600
3300
3130
WEIGHT (kg)
45
66
67
85
88
NOISE dB(A) @ 3m
56
58
58
59
59
MAX. MOUNTING HEIGHT (m)
3.5
3.5
3.5
3.5
3.5
PUHZ-RP71VHA4
PUHZ-RP71VHA4
PUHZ-RP140VKA/yKA
PUHZ-RP100VKA/yKA
PUHZ-RP200yKA
OUTDOOR UNIT MODEL
Notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load (1.3 amp load for PHV1000R DXE HO)
AIR CURTAIN PHV1000/1500/2000 DXE Side View
>
Rear View
>
*2 for units with electric heaters disabled, 240v power supply 2.7 amp load.
PHV DXE - FREE STANDING DIMENSIONS (mm) (WxDxH) SUPPLy (50Hz)
PHV1000 DXE HO
PHV1500 DXE LO
PHV1500 DXE HO
PHV2000 DXE LO
PHV2000 DXE HO
1196x377x255
1746x377x255
1746x377x255
2296x377x255
2296x377x255
415V*1
415V*1
415V*1
415V*2
415V*2
HEAT OUTPUT (kW)
100% / 50%
8.6 / 5.34
10.1 / 5.6
14.4 / 8.3
14.1 / 7.9
21.3 / 11.2
COP
100% / 50%
2.4 / 3.15
2.3 / 3.4
2.5 / 3.7
2.9 / 3.7
2.4 / 3.2
LOADING (amps)
7.8*1
12.7*1
12.7*1
15.7*2
15.7*2
VELOCITy (m/s)
9
9
9
9.5
9
1400
2500
2600
3300
3130
39
59
60
78
80
AIR VOLUME (m3/h) WEIGHT (kg) NOISE dB(A) @ 3m MAX. MOUNTING HEIGHT (m) OUTDOOR UNIT MODEL
56
58
58
59
59
3.75
3.75
3.75
3.75
3.75
PUHZ-RP71VHA4
PUHZ-RP71VHA4
PUHZ-RP140VKA/yKA
PUHZ-RP100VKA/yKA
PUHZ-RP200yKA
Notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load (1.3 amp load for PHV1000 DXE HO)
*2 for units with electric heaters disabled, 240v power supply 2.7 amp load.
Upper View
> PHV DXE Air Curtain
MODEL REFERENCE
PHV1000 DXE PHV1500 DXE PHV2000 DXE
HEAT PUMP OUTDOOR UNITS MODEL REFERENCE
PUHZ-RP71VHA4
PUHZ-RP100VKA/YKA
PUHZ-RP140VKA/YKA
PUHZ-RP200YKA
950x330+30x943
1050x330+30x1338
1050x330+30x1338
1050x330+30x1338
230V
230V / 415V
230V / 415V
415V
MAX. CURRENT (A)
19
26.5 / 8
28 / 11
19
FUSE SIZE HRC (BS88)
20
32 / 10
32 / 16
20
50
50
50
100
DIMENSIONS (mm) (WxDxH) SUPPLy (50Hz)
MAX. PIPE RUN PIPE SIZES
Length (m) Height (m)
30
30
30
30
Gas mm(in)
15.88 (5/8)
15.88 (5/8)
15.88 (5/8)
28.58 (1 1/8)
Liquid mm(in)
9.52 (3/8)
9.52 (3/8)
9.52 (3/8)
9.52 (3/8)
2 core
2 core
2 core
2 core
INTERCONNECTING CABLE
Page 118
Page 119
Sensible Cooling Wall Mounted System
INDOOR UNIT PHV2000 NT
In collaboration with Thermoscreens®, Mitsubishi Electric have developed a sensible cooling wall mounted unit that can be connected to our air to water heat pumps in cooling mode. These systems offer 100% sensible cooling (SHF of 1) for use in server rooms and other sensible cooling applications. SHF of 1 and capacity validated by 3rd party assessment (BSRIA)
I
Reduced CO2 emissions
I
Reduced Running Costs
I
Inverter technology (does not waste energy)
I
Easy to install and maintain
I
Ideal for small to medium size server rooms / laboratories
I
No 3rd party humidifier is required
I
PAR-W21MAA controller included
I
Pump not included
Side View
>
Rear View
>
C. 150min. for pipes
I
Dimensions
295
255
Upper View Upper View
>
>
168
Technical Information
Mr Slim Range
PHV NT Chilled Water Heat Pump
PHV NT - INDOOR UNITS MODEL REFERENCE
2296
Depth
377
Height
255
Cooling
12.0
SHF
1.0
EER
3.8
ELECTRICAL SUPPLy
OUTDOOR UNIT PUHZ-HW140VHA2 / PUHZ-HW140yHA2
220-240v, 50Hz Rear Air Intake
2.7
VELOCITy (m/s)
9
AIR VOLUME (m3/h)
Upper View
2885
WEIGHT (kg)
>
210
59
Side Air Intake
53
36 5.1
30
HyDRAULIC RESISTANCE (kPa @ 3.18 m3/h) WATER VOLUME OF COIL (litres)
330
3.18
Notes: Water flow temperature to be set to 10ºC (cannot be set lower). Includes room/return air temperature control, remote On/Off and room over-heat alarm. Test conditions: 35ºC DB / 27ºC WB outdoor conditions, 24ºC DB / 40% relative humidity indoor conditions - validated by BSRIA assessment.
Air Discharge
Front View PUHZ-HW - OUTDOOR UNITS
>
1020
1020
Depth
330 + 30
330 + 30
Height PHASE AIRFLOW (m3/min)
1350
1350
220-240v, 50Hz
380-415v, 50Hz
Single
3
100
100
HyDRAULIC RESISTANCE (kPa @ 3.18 m3/h)
15
15
WATER VOLUME IN HEAT EXCHANGER (litres)
2.5
2.5 7.6 [13]
40
16
MAINS CABLE No. CORES
3
5
CHARGE R410A (kg)
4.3
4.3
OPERATING RANGE
-5ºC ~ +46ºC
-5ºC ~ +46ºC 23
22.2 [35]
FUSE RATING (BS88) - HRC (A)
40
Width
74
148
VHA 1079 YHA 931
134
635
53
WEIGHT (kg)
ELECTRICAL SUPPLy
>
PUHZ-HW140YHA2
53
1350
PUHZ-HW140VHA2
NOISE (dBA)
Page 120
Side View
1020 322
MODEL REFERENCE
RUNNING CURRENT (A) [MAX]
370
WATER VOLUME FLOW RATE (m3/h)
210
28
NOISE (dBA) @ 3m
DIMENSIONS (mm)
600 Installation Feet
90
PHV NT Sensible Cooling Chilled Water Heat Pump
LOADING (A)
19
Single
417
PHASE
371
CAPACITy (kW)
PHV2000 NT Width
36
DIMENSIONS (mm)
34
Page 121
Technical Information
Inverter Heat Pump
Multi-Split Systems - Combinations Table
The multi-split system is an ideal option for open plan spaces in medium sized premises such as offices or shops, where two, three or four units are required. These can be Mr Slim ceiling cassettes (PLA-RP & SLZ-KA), ceiling suspended (PCA-RP), ducted (PEAD-RP), floor standing (PSA-RP) or wall mounted (PKA-RP) models and can be connected to a single outdoor unit using twin, triple or quadruple multi distributor pipes. I
Twin, triple or quadruple indoor heat pump units can be operated in Multi-Split configuration from a single outdoor unit
Indoor Unit
Outdoor Heat Pump
No. of Indoor Units
Total Heating Capacity (kW)
Total Cooling Capacity (kW)
Pipe Kit Part Number
Size 35
PUHZ-RP71
2
3.5 - 10.2
3.3 - 8.1
MSDD-50TR-E
Size 35
PUHZ-HRP71
2
4.5 - 10.2
4.9 - 8.1
MSDD-50TR-E
Size 50
PUHZ-P100
2
4.5 - 12.5
4.9 - 11.2
MSDD-50TR-E
I
Heat pumps must operate in same heating or cooling mode
Size 50
PUHZ-RP100
2
4.5 - 14.0
4.9 - 11.4
MSDD-50TR-E
I
Cooling capacity range 3.3 to 28kW
Size 50
PUHZ-HRP100
2
4.5 - 14.0
4.9 - 11.4
MSDD-50TR-E
I
Heating capacity range 3.5 to 31.5kW
Size 60
PUHZ-P125
2
5.0 - 16.0
5.5 - 14.0
MSDD-50TR-E
I
SLZ-KA indoor units can now be connected as part of a Mr Slim Multi-Split system
Size 60
PUHZ-RP125
2
5.0 - 16.0
5.5 - 14.0
MSDD-50TR-E
Size 60
PUHZ-HRP125
2
5.0 - 16.0
5.5 - 14.0
MSDD-50TR-E
Size 71
PUHZ-P140
2
5.0 - 18.0
5.5 - 15.0
MSDD-50TR-E
Size 71
PUHZ-RP140
2
5.0 - 18.0
5.5 - 15.3
MSDD-50TR-E
Size 50
PUHZ-P140
3
5.0 - 18.0
5.5 - 15.0
MSDT-111R-E
Note: SEZ-KD indoor units cannot be used as part of a Mr Slim Multi-Split system. PSA-RP indoor units cannot be connected with indoor units of different type. PCA-RP, PSA-RP and SLZ-KA indoor units cannot be connected to PUHZ-HRP outdoor units. PKA-RP indoor units cannot be connected to PUHZ-HRP71 & PUHZ-HRP125 outdoor units.
Technical Information
PIPE RUN PARAMETERS Outdoor Model
Pipe Runs
Max. Pipe Run (m)
Size 50
PUHZ-RP140
3
5.0 - 18.0
5.5 - 15.3
MSDT-111R-E
PUHZ-P100-140VHA3/yHA
A+B+C twin
50
PUHZ-P200/250yHA3
A+B+C twin
70
Size 100
PUHZ-P200
2
9.5 - 25.0
9.0 - 22.4
MSDD-50WR-E
Size 60
PUHZ-P200
3
9.5 - 25.0
9.0 - 22.4
MSDT-111R-E
Size 50
PUHZ-P200
4
9.5 - 25.0
9.0 - 22.4
MSDF-1111R-E
Size 100
PUHZ-RP200
2
9.5 - 25.0
9.0 - 22.4
MSDD-50WR-E
Size 60
PUHZ-RP200
3
9.5 - 25.0
9.0 - 22.4
MSDT-111R-E
Size 50
PUHZ-RP200
4
9.5 - 25.0
9.0 - 22.4
MSDF-1111R-E
Size 125
PUHZ-P250
2
12.5 - 31.5
11.2 - 28.0
MSDD-50WR-E
Size 71
PUHZ-P250
3
12.5 - 31.5
11.2 - 28.0
MSDT-111R-E
Size 60
PUHZ-P250
4
12.5 - 31.5
11.2 - 28.0
MSDF-1111R-E
Size 125
PUHZ-RP250
2
12.5 - 31.5
11.2 - 28.0
MSDD-50WR-E
Size 71
PUHZ-RP250
3
12.5 - 31.5
11.2 - 28.0
MSDT-111R-E
Size 60
PUHZ-RP250
4
12.5 - 31.5
11.2 - 28.0
MSDF-1111R-E
PUHZ-RP71VHA4
A+B+C twin
50
PUHZ-RP100-140VKA/yKA
A+B+C twin
75
PUHZ-RP200/250yKA
A+B+C twin
80 (120)
A+B+C twin
75
PUHZ-P140VHA3/yHA
A+B+C+D triple
50
PUHZ-P200/250yHA3
A+B+C+D triple
70
PUHZ-RP140VKA/yKA
A+B+C+D triple
75
PUHZ-RP200/250yKA
A+B+C+D triple
80 (120)
PUHZ-P200/250yHA3
A+B+C+D+E quadruple
70
A+B+C+D+E quadruple
80 (120)
PUHZ-P100-140VHA3/yHA
PUHZ-RP200/250yKA
B – C or C – D or B – D
PUHZ-RP71-140VHA4/VKA/yKA
B – C or C – D or B – D
≥8 ≥8 ≥8 ≥8 ≥8
PUHZ-HRP71-125VHA2/yHA2
B-C
PUHZ-P200/250yHA3
B - C or B - D or B - E or C - D or C - E or D - E
PUHZ-RP200/250yKA
B - C or B - D or B - E or C - D or C - E or D - E
H = 30m.
h = 1m.
Note: H for the PUHZ-RP200/250YKA = 40m
TWIN Indoor Units
Indoor Units
B
h
h
Page 122
B
C h
D
Indoor Units B
C
h Multi distributor Pipes
Outdoor Units
Multi distributor H Pipes
QUADRUPLE
TRIPLE
A
C D
Outdoor Units Multi distributor Pipes
A H
Multi-Split Systems
PUHZ-HRP71-125VHA2/yHA2
Mr Slim Range
Mr Slim Multi-Split Systems
A
E Outdoor Units
H
Page 123
Dimensions
SUZ-KA71VA2
SUZ-KA25/35VA2
>
400 Air in
Air in
17.5
40
Front View
Side View
Air out
>
>
Bolt pitch for installation 304~325
Upper View
44
285
344.5
Upper View
>
23
22.3
>
>
43
Side View
10
164.5
280
35
550
Front View
Mr Slim Range
Outdoor Units
150
99.5
69
170.5
302.5 500 Bolt pitch for installation 800
SUZ-KA50/60VA2 515
>
PUHZ-P100VHA3 / PUHZ-P100YHA
299 66
Air in
40
51 34
Upper View
Upper View
>
175
600
175 (19)
360
Installation Feet
A B C PUHZ-P100VHA3 443 670 66 PUHZ-P100YHA 431 589 56
370 417
330
Side Air Intake
Air out
840 121
F 56 54
>
C
D
53
Side View
80
28
>
30
Front View
E 45 41
E F
500
D 42 41
Air Discharge
>
Side View
950 322
>
A 23
155 90
35
447
473
30
430
B
943
850
Front View
Outdoor Unit Dimensions
330
Rear Air Intake
Air in
198
Dimensions Page 124
Page 125
Dimensions
PUHZ-P125/140VHA3 / PUHZ-P125/140YHA
PUHZ-RP35/50VHA4 400
A A PUHZ-P125/140VHA3 1076 PUHZ-P125/140VHA3 1076 PUHZ-P125/140YHA 994 PUHZ-P125/140YHA 994
417
41 54 370
330
Side Air Intake
Air intake
Air intake
330
Installation Feet
>
365
Upper View
175
300
600
155
175
152
>
(19)
Upper View
347.5 43.6
Rear Air Intake
Air Discharge
Front View
>
Side View
322
>
Side View
Air discharge
>
>
23 18
150
43
90
155
300 A
10
635
1350
35
600
Front View
950
40
32.5
41
53 28
30
45.4 56
Mr Slim Range
Outdoor Units
183
69 Installation bolt pitch: 500
447
371
431
287.5
23
800
PUHZ-RP60/71VHA4
PUHZ-P200/250YHA3
Rear air intake
A PUHZ-P200YHA3 PUHZ-P200YHA3 447 PUHZ-P250YHA3 PUHZ-P250YHA3 421
417
A 447 421
950
Side View
322
> Front View
57
41
Air discharge
>
Side View
950
>
447
431
473
439
A
23
23
371
339
673
943
995 999
635
1350
322
Dimensions Page 126
Page 127
Outdoor Unit Dimensions
>
29
Air Discharge
Front View
175
28
37
600 Installation Feet
53 28
40 56 370
330
61
175
Side air intake
Side Air Intake
30
>
19
Installation Feet
417
Upper View 175
40 54
600
53
175
330
>
(19)
Upper View
370
Rear Air Intake
Dimensions
PUHZ-RP100-140VKA / PUHZ-RP100-140YKA
PUHZ-HRP71/100VHA2 / PUHZ-HRP100/140YHA2
600 Installation Feet
Upper View
225
Rear air intake
175
Model A PUHZ-RP100-140VK A 1067 PUHZ-RP100-140YK A 919
70
60
42
600
175
Installation Feet
A
Side air intake 330
56 40 0 53
28
330
370 417
Side air intake
30
>
HRP.VHA2 HRP.YHA2
417
225
45 56 370
>
19
Upper View
(19)
Rear air intake
1079 930
66
42
53 28
30
Air discharge Air discharge
>
Side View
1050
>
Front View
>
Side View
950 322
>
447
443
26
371
369
442 450
A
635
A
1350
632
362
1338
Front View
Mr Slim Range
Outdoor Units
>
Rear air intake 600 Installation Feet
225
Model PUHZ-RP200YKA PUHZ-RP250YKA
Air discharge
>
60
42
B 442
56 40 0 53
Side View
1050 362
>
26
342 A B
369
982 986
632
1338
Front View
70
A 450 424
28
30
330
370 417
Side air intake
Outdoor Unit Dimensions
225
19
Upper View
23
PUHZ-RP200/250YKA
Dimensions Page 128
Page 129
M Series
The Air Handling Unit Controllers are an interface to allow connection to third party manufacturer equipment. Mitsubishi Electric Mr Slim outdoor units can be used with this interface box, creating an ideal solution when a unique air handling unit is required. I
No need for expansion device
I
Error, operation and defrost output
I
Demand control by analogue or digital inputs (0-10Ω , 4-20mA, 1-5V, 0-10V, Step, Auto-Step)
I
Now includes a third thermistor to enable Auto-Step
Wall Mounted Units
S70 515 716 S71 000 028
- Terminal block - CN22 connector
Ceiling Concealed Ducted Units
MAC-399IF MAC-397IF
- Interface for connection to M-NET System SEZ-KD25-71VAQ - Interface for group control and run/fault SEZ-KD25-71VAQ
4-Way Blow Cassette Units
PLP-6BA SLP-2AAW PAC-SH53TM-E PAC-SH59KF-E PLP-6BALM PLP-6BAJ PAC-SA1ME-E PAR-SA9FA-E S70E40714 MAC-399IF MAC-397IF
- Grille for PLA-RP35-140BA(2)(3) - Grille for SLZ-KA25-50VAQ - Multi function casement PLA-RP35-140BA(2)(3) for fresh air 100mm knockout or to hold the high efficiency filter option - High efficiency filter PLA-RP35-140BA(2)(3) - Grille and infra-red controller PLA-RP35-140BA(2)(3) - Grille with filter lowering function PLA-RP35-140BA(2)(3) - ‘I-See Sensor’ corner panel PLA-RP35-140BA(2)(3) - Infra-red signal receiver PLA-RP35-140BA(2)(3) - Infra-red controller (PAR-SL97A-E) PLA-RP35-140BA(2)(3) - Interface for connection to M-NET System SLZ-KA25-50VAQ - Interface for group control and run/fault SLZ-KA25-50VAQ
Ceiling Suspended Units
PAR-SL94B-E PAC-SH83DM-E PAC-SH85DM-E PAC-SH84DM-E PAC-SG38KF-E PAC-SF81KC-E PAC-SF82KC-E
-
Outdoor Units
PAC-SG61DS-E
PAC-SH95AG-E
- Drain socket set PUHZ-RP35-250VHA4/VKA/YKA / PUHZ-P100-250VHA3/YHA/YHA3 / PUHZ-HRP71-125VHA2/YHA2 - Air outlet guide PUHZ-RP35-50VHA4 - Air outlet guide PUHZ-RP60-71VHA4 / PUHZ-P100VHA3/YHA / PUHZ-P125-250VHA3/YHA/YHA3 (2 sets required) / PUHZ-HRP71-125VHA2/YHA2 (2 sets required) - Air outlet guide PUHZ-RP100-250VKA/YKA (2 sets required) - Air protect guide (allows cooling at -15ºC) PUHZ-RP35-50VHA4 - Air protect guide (allows cooling at -15ºC) PUHZ-RP60-71VHA4 / PUHZ-P100VHA3/YHA / PUHZ-P125-250VHA3/YHA/YHA3 (2 sets required) / PUHZ-HRP71-125VHA2/YHA2 (2 sets required) - Air protect guide (allows cooling at -15ºC) PUHZ-RP100-250VKA/YKA (2 sets required)
System Control Units
PAC-SA89TA-E PAC-SF40RM-E PAC-SE41TS-E PAC-SF81MA PAC-YT51CRB PAR-30MAA PAC-SK82SI-E
-
Remote on/off adaptor Run/fault indication Remote sensor A/M-NET adaptor Simplified remote controller Wired controller Sub interface board
Pipe Kits
MSDD-50TR-E MSDD-50WR-E MSDT-111R-E MSDF-1111R-E
-
Multi distribution pipe twin units - 50:50 - sizes 71/100/125/140 Multi distribution pipe twin units - 50:50 - sizes 200/250 Multi distribution pipe triple units - 33:33:33 - sizes 140/200/250 Multi distribution pipe quadruple units - 25:25:25:25 - sizes 200/250
Power Supply Terminal Kits
PAC-SH52HR-E PAC-SG94HR-E PAC-SG96HR-E PAC-SG97HR-E
-
Power supply terminal kit for PLA-RP when using PUHZ-RP200/250YKA Power supply terminal kit for PKA-RP when using PUHZ-RP200/250YKA Power supply terminal kit for PCA-RP / PSA-RP when using PUHZ-RP200/250YKA Power supply terminal kit for PEAD-RP / PCA-RP-HAQ when using PUHZ-RP200/250YKA
Technical Information PAC-IF012B-E MITSUBISHI ELECTRIC OUTDOOR UNIT CAPACITy (kW) AUTO STEP
SIZE 35
SIZE 50
SIZE 60
SIZE 71
SIZE 100
SIZE 125
SIZE 140
SIZE 200
SIZE 250
Heating (nominal)
4.1
6.0
7.0
8.0
11.2
14.0
16.0
22.4
27.0
Cooling (nominal)
3.6
5.0
6.0
7.1
10.0
12.5
14.0
19.0
22.0
VHA4
VHA4
VHA4
VHA4
VKA/yKA
VKA/yKA
VKA/yKA
yKA
yKA
PUHZ-RP PUHZ-P
-
-
-
-
VHA3/yHA
VHA3/yHA
VHA3/yHA
yHA3
yHA3
SUZ-KA
VA2
VA2
VA2
VA2
-
-
-
-
-
VHA2
VHA2/yHA2
yHA2
VHA4
VHA4
VHA4
VHA4
VKA/yKA
VKA/yKA
VKA/yKA
yKA
yKA
VHA2
VHA2/yHA2
yHA2 28.58 / 12.7
PUHZ-HRP MANUAL STEP
PUHZ-RP PUHZ-HRP
PIPE SIZE (mm)
PUHZ-(H)(R)P
12.7 / 6.35
12.7 / 6.35
15.88 / 9.52
15.88 / 9.52
15.88 / 9.52
15.88 / 9.52
15.88 / 9.52
28.58 / 9.52
Gas / Liquid
SUZ-KA
9.52 / 6.35
12.7 / 6.35
15.88 / 6.35
15.88 / 9.52
-
-
-
-
-
HEAT EXCHANGER VOLUME (cm3)
Max Capacity
1050
1500
1800
2130
3000
3750
4200
6000
7500
Min Capacity
350
500
600
710
1000
1250
1400
2000
2500 336
DIMENSIONS (mm)
Width
336
336
336
336
336
336
336
336
Depth
69
69
69
69
69
69
69
69
69
Height
278
278
278
278
278
278
278
278
278
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
WEIGHT (kg)
PAC-SG58SG-E PAC-SG59SG-E PAC-SH96SG-E PAC-SG56AG-E PAC-SH63AG-E
Note: One air handling unit controller is required per air handling unit Cooling: Indoor 27ºC DB/19ºC WB, Outdoor 35ºC DB/24ºC WB Heating: Indoor 20ºC DB, Outdoor 7ºC DB/6ºC WB
Example:
Air Handling Unit Controller (Mitsubishi Electric)
A Control wiring
Wireless remote controller and adaptor Optional drain lift pump PCA-RP50KAQ Optional drain lift pump PCA-RP60KAQ Optional drain lift pump PCA-RP71-140KAQ Oil mist filter for PCA-RP71/125HAQ (12 pack) Decoration covers (front cover & suspending bracket) for PCA-RP71HAQ Decoration covers (front cover & suspending bracket) for PCA-RP125HAQ
Controller (field supplied)
Thermistor wiring
Piping
Outdoor Unit (Mitsubishi Electric)
Page 130
Air Handling Unit (field supplied)
Page 131
Air Handling Unit Controller / Accessories / Optional Extras
Air Handling Unit Controller
Mr Slim Range
Accessories / Optional Extras
PAC-IF012B-E
City Multi Energy Efficient VRF Systems
Air Conditioning Commercial Heating Domestic Heating Photovoltaics
The City Multi Range: Solutions for More Demanding Applications
Efficient and Flexible The City Multi range is Mitsubishi Electric’s answer to large scale VRF (Variable Refrigerant Flow) applications. The efficiency of City Multi is second to none and offers a substantial increase in energy efficiency, with corresponding EER/COP ratings.
The strength of
City Multi The R410A YJM-A series offers some of the highest EER/COP ratings in the market.
The City Multi Y Series range offers a simple and flexible solution where there is a demand for a changeover capability between heating and cooling, helping to ensure a constant, comfortable indoor climate. Mitsubishi Electric also has the ability to provide simultaneous heating and cooling through its R2 and WR2 systems. This is achieved through only two pipes rather than the conventional three. Further developments with the City Multi range now enable heat to be moved to areas of a building that can best make use of it, these include air curtains and the generation of hot water. By moving heat in this way the system becomes central to providing a wider range of environmental services and further increases the run cost and CO2 emission reductions you would normally expect, as well as generating the hot water from this renewable heat source. By using Mitsubishi Electric’s 2-pipe heat recovery technology, substantial savings can again be made on annual running costs. With a range of over 80 indoor units, up to 50 (depending on the capacity available) can be connected to a YJM-A outdoor unit. Broadening the range of potential City Multi applications is Mitsubishi Electric’s 4th generation water cooled R410A WR2 system. This system not only produces heat recovery from the refrigerant circuit but also via its water circuit, offering double heat recovery potential.
Sophisticated technology, combined with a high level of control and energy efficiency: City Multi is perfectly positioned to meet the demands of today’s market.
Page 134
Page 135
The Basics: What is VRF? VRF stands for Variable Refrigerant Flow. A VRF air conditioning system modulates the flow of refrigerant depending upon the capacity requirements of the building. A VRF system comprises of a condensing unit sited externally and a series of multiple indoor units to provide cooling and/or heating to the occupied space.
Our Answer to VRF Mitsubishi Electric sets the boundaries of VRF technology with the City Multi range, which is available using R410A refrigerant. The range has been specifically designed for today's building requirements and addresses key market issues such as energy efficiency, adaptability and reliability. Mitsubishi Electric manufactures the only 2-pipe heat recovery simultaneous heating and cooling system in the world and equally unique, a water-cooled version. With user friendly control systems utilising internet technology and integrated cooling and ventilation indoor units, City Multi is the benchmark and market leader in VRF technology.
What is Inverter Driven Technology? Mitsubishi Electric spends more than 5% of its turnover on research and development, with our engineers always looking at ways in which we can improve and lead in air conditioning efficiency. The use of inverter technology in our City Multi systems is paramount in this process, working by varying the compressor speed to match the cooling or heating load, thereby consuming only the power necessary to match the exact requirement of the room. When City Multi is operating at partial load, the energy efficiency of the system is significantly higher than at full load. In a typical application partial load conditions prevail for more than 90% of operation time. A fixed speed system can only operate at 100% capacity and cannot match the annual efficiencies of an inverter system
What is a Heat Pump System? Mitsubishi Electric’s City Multi Y and WY Series’ are heat pump systems, which provide either heating or cooling to a building at any given time.
What is a Heat Recovery System?
Why R410A? R410A is a more efficient refrigerant as it has a higher specific heat capacity when compared to R407c or R22. This higher energy carrying capacity allows for smaller pipe sizes, longer pipe runs and reduces the volume of refrigerant within a system. This is a major factor when complying with EN378, a European standard concerning safety and environmental requirements in the design, manufacture, installation, operation, maintenance and disposal of refrigerating systems.
How Does the R2 / WR2 Heat Recovery System Operate on 2 Pipe’s? The secret of City Multi heat recovery systems lies in the BC Controller
Why Heat Recovery? Flexibility and efficiency are key factors when selecting a heat recovery system. For example, while a heat pump system is adequate for a large open plan office, businesses that have a more partitioned structure to an office will require the need to simultaneously heat or cool different sections of the office according to each users individual preferences. The efficiency of this type of system comes from the ability to use the by-products of cooling and heating to transfer energy where it is required, thus acting as a balanced heat exchanger achieving up to 20% cost savings over a conventional heat pump system. The number of connection sites needed for a R2 / WR2 system are also significantly lower than those needed for a three pipe version. This helps to reduce installation costs, further increasing the savings associated with City Multi.
The BC Controller houses a liquid/gas separator, allowing the outdoor unit to deliver a mixture (2 phase) of hot gas for heating and liquid for cooling, all through the same pipe. Three pipe systems allocate a pipe to each of these phases. When this mixture arrives at the BC Controller, it is separated and the correct phase delivered to each indoor unit depending on the individual requirement of either heating or cooling.
Comparison Example of Piping Connection Sites
Mitsubishi Electric’s City Multi R2 and WR2 Series’ have the ability to provide heating and cooling at the same time in areas connected to the same outdoor unit.
Page 136
Page 137
The Technology to Make City Multi the Natural Choice
Total Energy Conservation
Energy efficiency has always been the driver for City Multi technological development that always delivers the quality and reliability needed for commercial air conditioning environments. Mitsubishi Electric spend more than 5% of their turnover on research and development, with our engineers always looking at ways in which we can improve and lead in air conditioning efficiency.
City Multi R410A YJM-A Technology
Stable and Smooth Operation: 100% Inverter Control
Using the ver y latest in IPM (Intelligent Power Module) technology, precise control of energy input is achieved allowing City Multi to fur ther improve COPs for R410A systems. IPM uses 1Hz steps of capacity control, matching building requirements through more accurate control of the occupied space with reduced power input.
All City Multi compressors are inverter-driven and capable of precisely matching a building's cooling and heating demands.
As in previous versions, IPM technology operates extremely effectively under part load conditions (50-80% of operating capacity), a condition that most systems will be in for their normal working life. Therefore the consideration of efficiency at part load is accounted for as well as when at peak load conditions, offering high system efficiency all year round.
The outdoor unit combinations comprise of one module for 8-18hp systems, two modules for 20-36hp systems and three modules for 38-50hp systems (Y series only). Each module carries one inverter compressor making simple and highly reliable control possible. Not only does it allow low starting currents, the inverter driven compressor also provides precise indoor comfort and adapts to the air conditioning load, achieving smooth transition across the range of compressor frequencies
Heat Interchange Circuit
The Importance of COP
To further enhance the class leading efficiency of City Multi, the unique Heat Interchange Circuit provides extra sub cooling. This system allows optimum refrigerant distribution to multiple indoor units, by allowing more effective use of refrigerant flowing through the electronic expansion valves.
COP stands for â&#x20AC;&#x153;Co-efficient of Performanceâ&#x20AC;?. It is a measure of the useful energy a system can deliver compared to the energy that it consumes. It is calculated by dividing the energy output by the energy input of a system. The higher the figure then the more efficient the system is deemed to be, with commensurate reduced running costs.
Because of the added efficiency, volumes of refrigerant in systems are continuing to reduce.
City Multi Systems: 8-18hp
For Heat Pumps to be included on the Energy Technology Product List under the Enhanced Capital Allowance scheme, they must fall within the criteria specified by the ECA. For further information on qualification please visit www.eca.gov.uk
Total Energy Conservation CITY MULTI REFRIGERANT CIRCUIT
NORMAL REFRIGERANT CIRCUIT
Comparison of COP (energy efficiency) of an 8hp YJM-A system.
City Multi Systems: 20-36hp
The Difference Between YJM-A and Previous Mitsubishi Electric Models City Multi Systems: 38-50hp
31%
4.13
36%
4.46
Technology is key when increased efficiency is demanded. The City Multi YJM-A range is designed to deliver this. A highly efficient R410A scroll compressor design results in less friction losses at the motor. A simplified refrigerant circuit (low pressure loss) including new accumulator design also adds a few more points to the efficiency scale. Enhancements to the heat interchange circuit, inverter driven fan motor and heat exchanger design, again add vital increases to overall system efficiency and COPs.
Page 138
Page 139
Ground Source Heat Pumps
Smaller YHM-A models now available, in a wider variety of sizes
A very efficient source of energy for water source heat pump systems is the Earth itself. Ground source heat pumps use the Earth's natural solar collection and heat storage capabilities as an infinite heat source/heat sink.
City Multi Zubadan Air Source Heat Pumps
At between 1.7m and 3m below the ground, the temperature changes from 17ºC in the summer to 10ºC in the winter. Deeper down however, the temperature of the ground is a constant 10ºC all year round. It is these relatively constant, dependable temperatures that can be harnessed using ground source heat pumps. The constant ground temperatures allow the heat pump to operate at optimum efficiency in both heating and cooling, as the high summer or low winter temperatures do not influence performance. Heat is extracted or rejected into the ground using water which is pumped through a network of plastic pipes.
There are two standard ground source methods available, Open Loop and Closed Loop (Bore Hole or Slinky): I
Open Loop - Large bodies of water can be utilised as a stable source of water at a relatively constant temperature. This can be either surface water or ground water. Surface water would include lakes, reservoirs, rivers and the sea.
I
I
Closed Loop Slinky - A trench is dug to a depth of between 1.7 to 3m and plastic spiral pipe is laid into the bottom.
The City Multi Zubadan heat pumps achieve an excellent heating performance even when the outdoor air temperature is as low as -25°C. These models make use of a Flash Injection Circuit, which allows the optimal amount of refrigerant to be provided to the system via the compressor through a specially designed injection port. In simple terms, the system allows a quick start up time and continuous heating; even in low ambient conditions.
The pipe is covered with sand to provide good ground to pipe contact and then the trench is backfilled with the excavated soil.
Expanded Heating Operation
Stable Heating Performance
Closed Loop Bore Hole - A series of holes are drilled down into the ground at a depth of 50 to 130m, depending
Will work effectively even when the outdoor ambient air temperature is -25°C.
Full heating capacity at -15°C, a 30% capacity improvement over the standard YJM-A model.
on geothermal conditions. Two water pipes connected via a 'u bend' are fed directly into these holes and then surrounded by a conductive grout.
J (kW)
Example of a Closed Loop Bore Hole Application:
PUHY-HP400 YSHM-A
50.0
Full heating capacity even at -15°C Capacity improvement of 30%
I
T MUL CITY M-A dard YSJ Stan Y-P400 PUH
PUHY-HP250 YHM-A
25.0
MULTI rd CITY Standa 250 YJM-A PUHY-P
10.0
-25
-20
-15
-10
3 -5 0 Outdoor temp.°C (W.B.)
Stable Operation
Quick Start-Up
Utilising the new Flash Injection Circuit the Zubadan models have reduced defrost times and can provide continuous heating for up to 250 mins.
Full heating capacity is achieved in about 20 mins, improving comfort levels.
Indoor units provide heating or cooling Ground Source Heat Pump installed inside the building, typically one per floor
J
Flow and return water loop supplies water to and from the units Bore holes absorb or reject heat from the ground
Page 140
Page 141
Features and Benefits
Fine Control of the Inverter Provides Better Efficiency and Performance Air cooled inverters use the ambient temperature to cool the inverter. For water cooled VRF (which are installed inside the building) refrigerant cooling is used to maintain accurate control of the Inverter.
High Off Coil / High Sensible Cooling Poor design or application of air conditioning systems can sometimes lead to cold draughts and uneven room temperatures. Low off coil temperatures cause dehumidifying of the air which can create dry eyes and sore throats. Mitsubishi Electric now provides a High Sensible Cooling Function specifically designed to deal with this. By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants. These high SHF’s are available throughout the range of indoor units, allowing optimum selection of units tailored to more specific design criteria.
Reduced Noise Levels: New Fan Design City Multi VRF systems led the introduction of larger single fan rotors some ten years ago, achieving substantially lower noise levels over multiple designs. Continuing the development in the areas of blade shape and weight, Mitsubishi Electric have managed to achieve even higher performance and lower noise levels. To reduce noise levels further and comply with inner city residential noise regulations, all outdoor units include Night Set-back mode. This function works by lowering the fan speed and compressor frequency proportionally with reduction in demand (44dBA for PUHY-P250YJM-A). The compressor compartment is also now sealed, further reducing noise levels.
Refrigerant Volume Checking Function New fan design
Fin Structure
Reduction of operation noise
Slits
Replace Technology
New control box design Improvement of reliability and easy maintenance
New heat exchanger design A cross-steer fin structure with additional slits helps to improve COP by up to 2% in cooling. The heating COP is also improved by 1% with the introduction of a 2.5 row heat exchanger, improving airflow and temperature valance.
Previous YHM-A
New YJM-A
Heat Exchanger
Page 142
The latest VRF Replace Multi models from Mitsubishi Electric are specifically designed for the maturing refurbishment sector, enabling the reuse of existing R22 / R407c pipework, whilst also allowing the upgrade to some of the most efficient systems available in the market. Replace Multi will clean the existing pipework during commissioning, removing any deposits and R22 mineral oil that would have ordinarily meant that new pipework would have been called for. The implications of this are significant savings on cost and time, whilst also minimising any potential disruption.
Cooling Operation Set Temperature of 14ºC
New inverter compressor Improvement of COP and partial load performance thanks to the new concentrated winding structure.
This function runs the system, measuring various temperatures and pressures throughout the system, comparing these to the values stored in the units memory from the previous service. If a leakage has occurred the system will indicate so, enabling customers to easily comply with the F-Gas regulation.
YHM-A: 3 rows
YJM-A: 2.5 rows
Environments such as gyms, laboratories etc often require the ability to cool lower than the standard comfort cooling setpoint. By selecting a dip switch on the unit, a cooling operation set temperature of 14ºC DB is possible on the floor standing and ducted models only. The indoor unit fan will be fixed at high speed during this operation.
Page 143
Effective Use of Space YGM-A
The design of City Multi outdoor units makes installation easy
YJM-A Height 1710 mm
YJM-A models have a smaller foot print requirement when compared to the YGM-A models. The width and depth have been reduced by 7% and 13% respectively, with the height being reduced by 130mm (PUHY-P250YJM-A compared to PUHY-P250YGM-A).
Width 920mm
Approximately 21% reduction in foot print
Depth 760mm
8-12hp outdoor units
(PUHY-P250)
Easily Transported The unit can easily be transported, even into inaccessible buildings. Narrow space between buildings often makes it difficult to use a crane, City Multi helps to overcome this due to its design.
The downsized outdoor unit can also be transported through an 800mm wide lift door, making access to rooftops easier.
Example of lift
Weight Reduction Weight has been reduced by approximately 33kg per module. (PUHY-P250YJM-A compared to previous YGM-A versions).
Blue Fin Treatment The anti-corrosion Blue Fin treatment of the heat exchanger is especially effective in urban environments where traffic pollutions can damage the aluminium fins, reducing the capacity and life expectancy of the unit.
33kg
YGM-A
Page 144
YJM-A
All City Multi R410A outdoor units have been treated with Blue Fin
Page 145
High Performance Heating The new High Performance Heating mode is available on all YJM-A / YJM-B models and achieves an excellent heating performance at low outdoor air temperatures, making it ideal for the UK climate.
This means the pipe itself is cheaper, easier to install and less riser space is required within the building.
Activated by dip switch on the outdoor unit, COP priority or high performance heating modes can be selected. High performance heating mode is pre-selected on all YJM-A outdoor models.
Heating Operation Range: Standard & High COP air cooled units At low ambient temperatures the guaranteed operating range in heating is minus 20ºC Operating range in cooling is from an outdoor temperature of -5ºC. Outdoor Temperature (ºC)
Back-Up & Rotate
In COP priority mode, control is reverted back to normal and the power consumption lowered. However, even at -5°C the COP is kept high. High Performance Heating Mode COP Priority Mode
down, the remaining units will perform back-up operation until the faulty unit is repaired.
the load will be balanced between the units over time, extending the life of the system.
11% capacity increase
Heating Capacity Requirement (kW)
COP (P250 High Performance Heating Mode)
37.5
6.00 5.50
32.5
5.00 27.5
4.50 4.00
22.5
3.50
17.5
3.00 12.5 7.5
2.50 -4
-2
0
2
4
6
8
10
12
2.00
Outdoor Temperature (ºC)
1.1
Ratio of Heating Capacity
Rotation - In the case of two or three modules,
The ideal application for high performance heating mode is with a heating only system, or a system sized for a heating load as this is where substantial savings can be achieved. A system is designed for full load at a fixed design temperature, for example -3°C WB as in the example below. In this example, as the ambient temperature rises, the heating load decreases and the inverter is able to ramp the heat pump down, thus increasing efficiency.
In high performance heating mode, the control strategy is altered to allow the compressor to maintain a higher frequency at lower ambient temperatures, resulting in full nominal capacity down to -5°C on many models. What this means is that a smaller outdoor unit can be installed to produce the same capacity as a larger one would if it was in COP priority mode, therefore saving on both cost and space.
Back-up - In the case of one module breaking
Seasonal Efficiency
COP
Example of a 10hp model
As R410A has a higher specific heat capacity than R22, the pipework is smaller.
Heating Capacity required (kW)
R410A Pipe Sizing
1.0
Note: This is only a representation of a PUHY-RP250 over the winter period. Actual data varies depending on individual outdoor unit.
0.9 0.8 0.7 0.6 0.5 0.4
-20
-15
-10
-5 0 Ambient Temperature
5
10
15
Note: This is only a representation. Actual data varies depending on individual outdoor unit.
Page 146
Page 147
City Multi Exceeds Current Demands for Efficiency
Enhanced Capital Allowance Scheme (ECA)
The need for energy efficiency is paramount and is determined by legislation and regulation. In 2009 the Climate Change Act was updated, putting a greater emphasis on reducing energy use and thus CO2 emissions. 2010 also saw big changes with the introduction of the CRC Energy Efficiency Scheme (formerly the Carbon Reduction Commitment), which is a mandatory emissions trading scheme. It is central to the UKâ&#x20AC;&#x2122;s strategy for improving energy efficiency and reducing CO2 emissions. The scheme will affect around 5000 organisations, creating a financial incentive to actively reduce their CO2 emissions across their business as a whole. In addition to these, the newly revised Part L of the building regulations outlines the need to reduce carbon emissions by 25% on aggregate over a Part L 2006 building. These regulations show the positive steps being taken towards achieving highly energy efficient, zero carbon new buildings. Mitsubishi Electricâ&#x20AC;&#x2122;s range of energy efficient heating, cooling, ventilation and controls products all help to comply with these regulations and schemes. To encourage efficient use of energy, the UK Government introduced the Enhanced Capital Allowance Scheme (ECA). Qualifying products on the Energy Technology Product List include heat pumps for space heating. The City Multi range has been designed to ensure businesses qualify for ECA and benefit from the utmost efficiency, both financially and environmentally.
The Key Features of the Scheme: I Under the scheme, all businesses liable for UK corporation tax are able to claim an enhanced capital allowance
Mitsubishi Electric produces a series of comprehensive CPD approved Industry Information Guides, designed to enhance the knowledge of our customers and provide a view of all the key issues facing our industry today.
All our information guides are available to download from our website: www.mitsubishielectric.co.uk/aircon
Page 148
on any qualifying expenditure (regardless of size and location of business or whether in the industrial or commercial sector). I Businesses can offset the full cost of specific technologies (such as City Multi)
against taxable profits of the period of the investment. I In order to qualify for this scheme, technology has to meet the energy saving criteria as published in the
Energy Technology Criteria List. City Multi fully meets this criteria in its drive for energy efficiency. I Only investment in new and unused plant and machinery qualify.
For further information go to www.eca.gov.uk and click on Mitsubishi Electric Air Conditioning under the heat pump category.
Page 149
A Wide Choice of Models
Y Series (12hp) PUHY-EP YJM-A 12hp
PUHY-EP300 YJM-A
The YJM-A air sourced outdoor models are modular in design and as such differing combinations of them can be connected together to create the required outdoor unit size needed for a particular application. The new YJM-A models also now make use of an extra large single module.
Y Series (16hp) PUHY-EP YSJM-A
Both the Y and R2 Series come in Standard (-P) and High COP (-EP) versions. In addition, the standard versions allow for space-saving by virtue of the combination of units having a smaller foot print than the high COP versions.
Y Series (18hp) PUHY-EP YSJM-A
The model line up Size Series Y
R2
8hp
18hp
PUHY-EP400 YSJM-A
PUHY-EP450 YSJM-A
Y Series (20hp) PUHY-EP YSJM-A
200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 1250
Model Name
16hp
20hp
PUHY-EP500 YSJM-A
PUHY-P
n
n
n
PUHY-EP
n
n
n
PURY-P
n
n
n
PURY-EP
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
Y Series (22hp) PUHY-EP YSJM-A 22hp
24hp
Y Series Heat Pump - Standard Version Y Series (8-12hp) PUHY-P YJM-A PUHY-P200 YJM-A PUHY-P250 YJM-A PUHY-P300 YJM-A
Y Series (14-16hp) PUHY-P YJM-A
Y Series (36hp) PUHY-P YSJM-A 36hp
PUHY-P900 YSJM-A
Y Series (38-40hp) PUHY-P YSJM-A
14hp
PUHY-P350 YJM-A
38hp
PUHY-P950 YSJM-A
16hp
PUHY-P400 YJM-A
40hp
PUHY-P1000 YSJM-A
Y Series (18hp) PUHY-P YJM-A 18hp
PUHY-P450 YJM-A
Y Series (20-22hp) PUHY-P YSJM-A PUHY-P500 YSJM-A
22hp
PUHY-P550 YSJM-A
Y Series (24-26hp) PUHY-P YSJM-A
Y Series (42hp) PUHY-P YSJM-A 42hp
PUHY-P1050 YSJM-A
Y Series (44hp) PUHY-P YSJM-A 44hp
PUHY-P1100 YSJM-A
Y Series (46-48hp) PUHY-P YSJM-A
24hp
PUHY-P600 YSJM-A
46hp
PUHY-P1150 YSJM-A
26hp
PUHY-P650 YSJM-A
48hp
PUHY-P1200 YSJM-A
PUHY-EP550 YSJM-A
PUHY-EP600 YSJM-A
R2 Series (8-12hp) PURY-P YJM-A 8hp 10hp 12hp
PURY-P200 YJM-A PURY-P250 YJM-A PURY-P300 YJM-A
R2 Series (14-16hp) PURY-P YJM-A
Y Series (28-30hp) PUHY-P YSJM-A PUHY-P700 YSJM-A
30hp
PUHY-P750 YSJM-A
Y Series (50hp) PUHY-P YSJM-A 50hp
PUHY-P800 YSJM-A
34hp
PUHY-P850 YSJM-A
8hp
Page 150
PUHY-EP200 YJM-A
PUHY-EP700 YSJM-A
Y Series (30hp) PUHY-EP YSJM-A 30hp
PUHY-EP750 YSJM-A
Y Series (32hp) PUHY-EP YSJM-A 32hp
PUHY-EP800 YSJM-A
10hp
PUHY-EP850 YSJM-A
Y Series (36hp) PUHY-EP YSJM-A 36hp
PUHY-EP900 YSJM-A
R2 Series (26-28hp) PURY-P YSJM-A 26hp
PURY-P650 YSJM-A
28hp
PURY-P700YSJM-A
R2 Series (30-32hp) PURY-P YSJM-A 30hp
PURY-P750 YSJM-A
32hp
PURY-P800YSJM-A
R2 Series (18hp) PURY-P YJM-A PURY-P450 YJM-A
R2 Series (18-24hp) PURY-P YSJM-A(1) 18hp 20hp 22hp 24hp
PURY-P450 YSJM-A1 PURY-P500 YSJM-A PURY-P550 YSJM-A PURY-P600 YSJM-A
R2 Series (34hp) PURY-P YSJM-A 34hp
PURY-P850 YSJM-A
R2 Series (36hp) PURY-P YSJM-A 36hp
PURY-P900 YSJM-A
R2 Series Heat Recovery - High COP Version 8hp
PURY-EP200 YJM-A
R2 Series (18-20hp) PURY-EP YSJM-A 18hp
PURY-EP450YSJM-A
20hp
PURY-EP500YSJM-A
R2 Series (22-24hp) PURY-EP YSJM-A
10hp
PURY-EP250 YJM-A
22hp
PURY-EP550YSJM-A
12hp
PURY-EP300YJM-A
24hp
PURY-EP600YSJM-A
14hp
PUHY-EP250 YJM-A
34hp
PURY-P400 YJM-A
R2 Series (14hp) PURY-EP YJM-A
Y Series (10hp) PUHY-EP YJM-A
Y Series (34hp) PUHY-EP YSJM-A
PURY-P350 YJM-A
R2 Series (10-12hp) PURY-EP YJM-A
Y Series Heat Pump - High COP Version Y Series (8hp) PUHY-EP YJM-A
28hp
16hp
PUHY-P1250 YSJM-A
Y Series (32-34hp) PUHY-P YSJM-A 32hp
Y Series (28hp) PUHY-EP YSJM-A
14hp
R2 Series (8hp) PURY-EP YJM-A
28hp
PUHY-EP650 YSJM-A
R2 Series Heat Recovery - Standard Version
18hp
20hp
26hp
10hp 12hp 14hp 16hp 18hp 20hp 22hp 24hp 26hp 28hp 30hp 32hp 34hp 36hp 38hp 40hp 42hp 44hp 46hp 48hp 50hp
Y Series (24hp) PUHY-EP YSJM-A
8hp 10hp 12hp
Y Series (26hp) PUHY-EP YSJM-A
PURY-EP350 YJM-A
R2 Series (16hp) PURY-EP YSJM-A 16hp
PURY-EP400 YSJM-A
R2 Series (26hp) PURY-EP YSJM-A 26hp
PURY-EP650YSJM-A
R2 Series (28hp) PURY-EP YSJM-A 28hp
PURY-EP700YSJM-A
Page 151
City Multi Product Range Overview Outdoor Units 140kW Cooling Capacity
11.2kW Cooling Capacity Y Series (4/5/6hp)
WY / WR2 Series
Y Series Zubadan
Y Series Replace Multi
R2 Series Replace Multi
Y / R2 Series
Y / R2 Series
Y / R2 Series
PUMY-P100-140V/YHMB
PQ(H/R)Y-P200-300YHM-A
PUHY-HP200/250YHM-A
PUHY-RP200-350YJM-B
PURY-RP200-300YJM-B
PUH/RY-P200-300YJM-A PUH/RY-EP200YJM-A
PUH/RY-P350/400YJM-A PUHY-EP250YJM-A PURY-EP250/300YJM-A
PUH/RY-P450YJM-A PUHY-EP300YJM-A PURY-EP350YJM-A
Indoor Units Model / Size
15 (1.7kW)
20 (2.2kW)
25 (2.8kW)
32 (3.6kW)
40 (4.5kW)
50 (5.6kW)
63 (7.1kW)
80 (9.0kW)
100 (11.2kW)
125 (14.0kW)
140 (16.0kW)
200 (22.4kW)
250 (28.0kW)
PLFY-P-VBM-E PLFY-P-VCM-E2 PLFY-P-VLMD-E PMFY-P-VBM-E PEFY-P-VMS1-E PEFY-P-VMA-E PEFY-P-VMH-E PCFY-P-VKM-E PKFY-P-VBM/VHM/VKM-E PFFY-P-VLRM-E PFFY-P-VLRMM-E PFFY-P-VLEM-E PFFY-P-VKM-E GUF-RD3 PWFY-P Page 152
Page 153
The energy efficient
City Multi VRF range Unique 2-pipe technology provides simultaneous heating and cooling, alongside excellent energy efficiency and corresponding EER/COP ratings. Up to 50 indoor units can be connected to a single outdoor unit, offering the sophistication, control and energy efficiency demanded today.
Contents 156
Y Series (4-6hp) Heat Pump, Outdoor Unit
200
WR2 Series (8-24hp) Heat Recovery, Water Cooled Condensing Unit
158
Y Series Standard (8-18hp) Heat Pump, Outdoor Unit
202
PFD-P-VM-E Heat Pump, Close Control System
160
Y Series Standard (20-30hp) Heat Pump, Outdoor Unit
204
PLFY-P-VBM-E 2, 3 and 4-Way Blow Ceiling Cassette Indoor Unit
162
Y Series Standard (32-36hp) Heat Pump, Outdoor Unit
206
PLFY-P-VCM-E2 600x600 4-Way Blow Ceiling Cassette Indoor Unit
164
Y Series Standard (38-44hp) Heat Pump, Outdoor Unit
208
PLFY-P-VLMD-E 2-Way Blow Ceiling Cassette Indoor Unit
166
Y Series Standard (46-50hp) Heat Pump, Outdoor Unit
210
PMFY-P-VBM-E 1-Way Blow Ceiling Cassette Indoor Unit
168
Y Series High COP (8-18hp) Heat Pump, Outdoor Unit
212
PEFY-P-VMS1-E Ultra Thin Ceiling Concealed Ducted Indoor Unit
170
Y Series High COP (20-24hp) Heat Pump, Outdoor Unit
214
PEFY-P-VMA-E Ceiling Concealed Ducted Indoor Unit
172
Y Series High COP (26-30hp) Heat Pump, Outdoor Unit
216
174
Y Series High COP (32-36hp) Heat Pump, Outdoor Unit
PEFY-P-VMH-E High Static Pressure Ceiling Concealed Ducted Indoor Unit
218
Y Series Zubadan (8-20hp) Heat Pump, Outdoor Unit
PCFY-P-VKM-E Ceiling Suspended Indoor Unit
220
Y Series Replace Multi (8-26hp) Heat Pump, Outdoor Unit
PKFY-P-VBM/VHM/VKM-E Wall Mounted Indoor Unit
222
Y Series Replace Multi (28-36hp) Heat Pump, Outdoor Unit
PFFY-P-VLRM-E Floor Standing Concealed Indoor Unit
224
WY Series (8-24hp) Heat Pump, Water Cooled Condensing Unit
PFFY-P-VLRMM-E Floor Standing Concealed Indoor Unit
226
WY Series (26-36hp) Heat Pump, Water Cooled Condensing Unit
PFFY-P-VLEM-E Floor Standing Exposed Indoor Unit
228
R2 Series Standard (8-18hp) Heat Recovery, Outdoor Unit
PFFY-P-VKM-E Floor Standing Exposed Indoor Unit
230
R2 Series Standard (18-28hp) Heat Recovery, Outdoor Unit
GUF-RD3 Lossnay Outdoor Air Processing Unit
232
R2 Series Standard (30-36hp) Heat Recovery, Outdoor Unit
PWFY-P VRF Heat Pump Boiler
234
R2 Series High COP (8-20hp) Heat Recovery, Outdoor Unit
VRF PHV DXE VRF Heat Pump Air Curtain
236
R2 Series High COP (22-28hp) Heat Recovery, Outdoor Unit
VRF PHV NT Sensible Cooling, Chilled Water Indoor Unit
238
BC Controllers
240
Water System Connection Box (WCB)
242
Air Handling Unit Controllers
243
Accessories / Optional Extras
176 178 180 182
Simple technology at its best
184 186 188 190
Many of our systems have an energy label of A, are registered on the Energy Technology List and hence qualify for 100% first year enhanced capital allowances (whole system cost and ‘reasonable’ cost of installation). For further information please go to www.eca.gov.uk
192 194 196
R2 Series Piping Restrictions
198
R2 Series Replace Multi (8-12hp) Heat Recovery, Outdoor Unit
Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB. Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB. UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. UK Conditions: Winter; indoor 21˚C DB; outdoor -1˚C WB.
Page 154
Page 155
Dimensions
Heat Pump Outdoor Unit
PUMY-P100-140VHMB/YHMB
The latest in Mitsubishi Electric R410A Y Series technology. The new City Multi models allow up to 12 indoor units to be connected to a single outdoor unit, using the standard branch/header pipework system proven in the larger models. Utilising the latest Mitsubishi Electric inverter technology, the system is fully controllable with all City Multi controllers or linked to third party BEMS.
I
A two core non-polar transmission line allows for simple installation of up to twelve indoor units now
I
Latest in inverter technology including a highly efficient DC Scroll Compressor, DC fan motor and Demand Control
I
The condensing unit is extremely slimline which allows easy location and application of the system
I
Single or three phase power supply
I
Anti-Corrosion blue and flat fin technology
Upper View
Side View
>
Front View
>
City Multi Range
Y Series (4-6hp)
>
Technical Information Y SERIES OUTDOOR UNITS 4-6hp MODEL REFERENCE
POWER INPUT (kW)
PUMY-P100VHMB PUMY-P100YHMB PUMY-P125VHMB PUMY-P125YHMB PUMY-P140VHMB PUMY-P140YHMB Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK) Heating (nominal) Cooling (nominal) Heating (UK) Cooling (UK)
COP / EER (nominal) Max no. OF CONNECTABLE INDOOR UNITS Max CONNECTABLE CAPACITY AIRFLOW (m3/min) PIPE SIZE mm(in) Gas Liquid NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) Width Depth Height ELECTRICAL SUPPLY PHASE STARTING CURRENT (A) RUNNING CURRENT (A) Heating Cooling GUARANTEED OPERATING RANGE Cooling Heating FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores
12.5 12.5 16.0 16.0 18.0 18.0 11.2 11.2 14.0 14.0 15.5 15.5 10.4 10.4 13.3 13.3 14.9 14.9 10.3 10.3 12.9 12.9 14.3 14.3 3.66 3.63 4.33 4.29 5.58 5.32 3.34 3.30 4.32 4.27 5.35 5.32 3.27 3.23 3.85 3.82 4.99 4.73 2.84 2.81 3.66 3.63 4.53 4.52 3.42 / 3.35 3.44 / 3.39 3.69 / 3.24 3.73 / 3.28 3.23 / 2.90 3.38 / 2.91 8 8 10 10 12 12 50-130% OU Capacity 50-130% OU Capacity 50-130% OU Capacity 50-130% OU Capacity 50-130% OU Capacity 50-130% OU Capacity 100 100 100 100 100 100 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 49 49 50 50 51 51 129 142 129 142 129 142 950 950 950 950 950 950 330+30 330+30 330+30 330+30 330+30 330+30 1350 1350 1350 1350 1350 1350 220-240v, 50Hz 380-415v, 50Hz 220-240v, 50Hz 380-415v, 50Hz 220-240v, 50Hz 380-415v, 50Hz Single 3 Single 3 Single 3 5 5 5 5 5 5 15.5 5.32 18.3 6.29 23.6 7.8 14.1 4.84 18.3 6.26 22.7 7.8 -5ºC ~ 46ºC -5ºC ~ 46ºC -5ºC ~ 46ºC -5ºC ~ 46ºC -5ºC ~ 46ºC -5ºC ~ 46ºC -15ºC ~ 15ºC -15ºC ~ 15ºC -15ºC ~ 15ºC -15ºC ~ 15ºC -15ºC ~ 15ºC -15ºC ~ 15ºC 32 16 32 16 32 16 3 4 + earth 3 4 + earth 3 4 + earth
Y Series (4-6hp)
CAPACITY (kW)
Optional Parts PUMY-P100-140VHMB/YHMB Piping Restrictions TOTAL PIPING LENGTH FURTHEST PIPING LENGTH FURTHEST PIPING LENGTH AFTER 1st BRANCH BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
Page 156
120m max 80m max 30m max 50m max (20m max if outdoor installed below) 12m max
Model Name
Description
CMY-Y62-G-E
Branch Pipe (2 Branch)
Page 157
Dimensions
Heat Pump Outdoor Unit
PUHY-P200, 250, 300YJM-A
Improved for even higher efficiency
Side View
>
Front View
>
Upper View
>
>
Upper View
>
The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained. I I I I I I I I
I
Wrap around coil for improved energy efficiency Choice of Branch Pipe or Header Pipe feeds to indoor units Energy-saving inverter driven outdoor compressor units with very low start currents No requirement for plant rooms or bulky service shafts Weight and size reduction compared to YGM-A models Improved pipe run of 165m, with a total system pipe length of 1000m 100% inverter control High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants High Performance Heating Mode for low ambient conditions
City Multi Range
Y Series Standard (8-18hp)
PUHY-P350, 400YJM-A Side View
>
Front View
Technical Information Y SERIES STANDARD OUTDOOR UNITS 8-18hp MODEL REFERENCE
POWER INPUT (kW)
PUHY-P200YJM-A PUHY-P250YJM-A PUHY-P300YJM-A PUHY-P350YJM-A PUHY-P400YJM-A PUHY-P450YJM-A Heating (nominal)
25.0
31.5
37.5
45.0
50.0
56.0
Cooling (nominal)
22.4
28.0
33.5
40.0
45.0
50.0
High Performance Heating (UK)
25.0
31.5
35.6
42.8
47.5
50.7
COP Priority Heating (UK)
22.8
28.7
32.3
38.7
43.0
48.7
Cooling (UK)
21.3
26.6
31.5
37.6
42.3
46.0
Heating (nominal)
5.84
7.34
9.25
11.19
12.82
14.62
Cooling (nominal)
5.62
7.40
9.00
11.01
13.11
15.47
High Performance Heating (UK)
7.36
9.25
12.40
14.99
17.18
16.67
COP Priority Heating (UK)
5.78
7.27
8.97
10.85
12.44
13.30
Cooling (UK)
3.23
4.26
5.81
7.10
8.46
9.75
4.28 / 3.98
4.29 / 3.78
4.05 / 3.72
4.02 / 3.63
3.90 / 3.43
3.83 / 3.23
COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS
17
21
26
30
34
39
AIRFLOW (m3/min)
170
170
170
210
210
370
High
NOISE (dBA)
56
58
59
60
61
62
WEIGHT (kg)
190
200
215
250
250
290
Width
920
920
920
1220
1220
1750
Depth
760
760
760
760
760
760
DIMENSIONS (mm) (1650mm without legs)
Height
1710
1710
1710
1710
1710
1710
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
PHASE
3
3
3
3
3
3
STARTING CURRENT (A)
8
8
8
8
8
8
Heating
9.0
11.3
14.2
17.2
19.8
22.5
Cooling
8.6
11.4
13.9
17.0
20.2
23.9
20
20
25
32
32
40
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
ELECTRICAL SUPPLY
RUNNING CURRENT (A)
FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores
PUHY-P450YJM-A Side View
>
Front View
>
Upper View
>
Y Series Standard (8-18hp)
CAPACITY (kW)
PUHY-P200-450YJM-A Piping Restrictions TOTAL PIPING LENGTH
1000m max
FURTHEST PIPING LENGTH
165m max
FURTHEST PIPING LENGTH AFTER 1st BRANCH
40m max
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
50m max (40m max if outdoor installed below)
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
15m max
Page 158
Page 159
Dimensions
Heat Pump Outdoor Unit
PUHY-P500, 550YSJM-A Side View
Improved for even higher efficiency
>
Front View
>
The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained. I I I I I I I I
I
Wrap around coil for improved energy efficiency Choice of Branch Pipe or Header Pipe feeds to indoor units Energy-saving inverter driven outdoor compressor units with very low start currents No requirement for plant rooms or bulky service shafts Weight and size reduction compared to YGM-A models Improved pipe run of 165m, with a total system pipe length of 1000m 100% inverter control High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants High Performance Heating Mode for low ambient conditions
City Multi Range
Y Series Standard (20-30hp)
PUHY-P600, 650YSJM-A Side View
>
Front View
>
Technical Information Y SERIES STANDARD OUTDOOR UNITS 20-30hp MODEL REFERENCE
PUHY-P500YSJM-A PUHY-P550YSJM-A PUHY-P600YSJM-A PUHY-P650YSJM-A PUHY-P700YSJM-A PUHY-P750YSJM-A
Heating (nominal)
63.0
69.0
76.5
81.5
88.0
95.0
Cooling (nominal)
56.0
63.0
69.0
73.0
80.0
85.0
High Performance Heating (UK)
57.0
62.4
69.2
73.8
88.0
95.0
COP Priority Heating (UK)
54.8
60.0
66.6
70.9
76.6
82.7
Cooling (UK)
51.5
58.0
63.5
67.2
73.6
78.2
POWER INPUT (kW) Heating (nominal)
15.03
16.87
18.88
20.47
22.27
24.67
Cooling (nominal)
15.38
17.16
18.75
20.39
22.47
24.70
High Performance Heating (UK)
17.13
19.23
21.52
23.34
28.06
31.08
COP Priority Heating (UK)
13.68
15.35
17.18
18.63
20.71
22.94
Cooling (UK)
9.69
10.81
11.81
12.85
14.49
15.93
4.19 / 3.64
4.09 / 3.67
4.05 / 3.68
3.98 / 3.58
3.95 / 3.56
3.85 / 3.44
COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min)
High
43
47
50
50
50
50
170 / 170
170 / 170
210 / 170
210 / 170
210 / 210
210 / 210
NOISE (dBA)
61
61.5
62
62.5
63
63.5
WEIGHT (kg)
200 + 200
215 + 200
250 + 200
250 + 215
250 + 250
250 + 250
920 + 920
920 + 920
1220 + 920
1220 + 920
1220 + 1220
1220 + 1220
DIMENSIONS (mm)
Width Depth
760
760
760
760
760
760
Height
1710
1710
1710
1710
1710
1710
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
3
3
3
3
3
3
8/8
8/8
8/8
8/8
8/8
8/8
RUNNING CURRENT (A) Heating
23.2
26.0
29.1
31.6
34.4
38.1
Cooling
23.7
26.5
28.9
31.5
34.7
38.1
20 / 20
25 / 20
32 / 20
32 / 25
32 / 32
32 / 32
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
(1650mm without legs) ELECTRICAL SUPPLY PHASE STARTING CURRENT (A)
FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores
PUHY-P700, 750YSJM-A Side View
>
Front View
>
Y Series Standard (20-30hp)
CAPACITY (kW)
PUHY-P500-750YSJM-A Piping Restrictions TOTAL PIPING LENGTH
1000m max
FURTHEST PIPING LENGTH
165m max
FURTHEST PIPING LENGTH AFTER 1st BRANCH
40m max
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
50m max (40m max if outdoor installed below)
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
15m max
Page 160
Page 161
Dimensions
Heat Pump Outdoor Unit
PUHY-P800, 850YSJM-A
Improved for even higher efficiency
Side View
The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained. I I I I I I I I
I
>
Front View
>
Front View
>
Wrap around coil for improved energy efficiency Choice of Branch Pipe or Header Pipe feeds to indoor units Energy-saving inverter driven outdoor compressor units with very low start currents No requirement for plant rooms or bulky service shafts Weight and size reduction compared to YGM-A models Improved pipe run of 165m, with a total system pipe length of 1000m 100% inverter control High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants High Performance Heating Mode for low ambient conditions
Technical Information
City Multi Range
Y Series Standard (32-36hp)
PUHY-P900YSJM-A
MODEL REFERENCE CAPACITY (kW)
POWER INPUT (kW)
PUHY-P800YSJM-A
PUHY-P850YSJM-A
PUHY-P900YSJM-A
Heating (nominal)
100.0
108.0
113.0
Cooling (nominal)
90.0
96.0
101.0
High Performance Heating (UK)
100.0
102.6
107.4
COP Priority Heating (UK)
87.0
95.0
99.4
Cooling (UK)
82.8
88.3
92.9
Heating (nominal)
25.70
28.42
30.05
Cooling (nominal)
27.10
29.62
32.06
High Performance Heating (UK)
32.38
37.80
39.97
COP Priority Heating (UK)
23.90
26.15
27.65
Cooling (UK)
17.48
18.07
19.56
3.89 / 3.32
3.80 / 3.24
3.76 / 3.15
COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min)
High
50
50
50
370 / 210
370 / 210
370 / 370
NOISE (dBA)
64
64.5
65
WEIGHT (kg)
290 + 250
290 + 250
290 + 290 1750 + 1750
DIMENSIONS (mm) (1650mm without legs)
Width
1750 + 1220
1750 + 1220
Depth
760
760
760
Height
1710
1710
1710
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
3
3
3
8/8
8/8
8/8
Heating
39.7
43.9
46.4
Cooling
41.8
45.7
49.5
40 / 32
40 / 32
40 / 40
4 + earth
4 + earth
4 + earth
ELECTRICAL SUPPLY PHASE STARTING CURRENT (A) RUNNING CURRENT (A)
FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores
Side View
>
Y Series Standard (32-36hp)
Y SERIES STANDARD OUTDOOR UNITS 32-36hp
PUHY-P800-900YSJM-A Piping Restrictions TOTAL PIPING LENGTH
1000m max
FURTHEST PIPING LENGTH
165m max
FURTHEST PIPING LENGTH AFTER 1st BRANCH
40m max
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
50m max (40m max if outdoor installed below)
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
15m max
Page 162
Page 163
Dimensions
Heat Pump Outdoor Unit
PUHY-P950, 1000YSJM-A Side View
Improved for even higher efficiency
>
Front View
>
The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained. I I I I I I I I
I
Wrap around coil for improved energy efficiency Choice of Branch Pipe or Header Pipe feeds to indoor units Energy-saving inverter driven outdoor compressor units with very low start currents No requirement for plant rooms or bulky service shafts Weight and size reduction compared to YGM-A models Improved pipe run of 165m, with a total system pipe length of 1000m 100% inverter control High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants High Performance Heating Mode for low ambient conditions
City Multi Range
Y Series Standard (38-44hp)
PUHY-P1050YSJM-A Side View
>
Front View
>
Technical Information Y SERIES STANDARD OUTDOOR UNITS 38-44hp CAPACITY (kW)
POWER INPUT (kW)
PUHY-P950YSJM-A
PUHY-P1000YSJM-A
PUHY-P1050YSJM-A
PUHY-P1100YSJM-A
Heating (nominal)
119.5
127.0
132.0
140.0
Cooling (nominal)
108.0
113.0
118.0
124.0
High Performance Heating (UK)
113.5
120.7
125.4
133.0
COP Priority Heating (UK)
105.2
111.8
116.2
123.2
Cooling (UK)
99.4
104.0
108.6
114.1
Heating (nominal)
30.02
33.15
34.10
36.08
Cooling (nominal)
30.50
32.10
33.81
35.73
High Performance Heating (UK)
39.93
44.09
45.35
47.99
COP Priority Heating (UK)
27.62
30.50
31.37
33.19
Cooling (UK)
18.61
19.58
20.62
21.80
3.98 / 3.54
3.83 / 3.52
3.87 / 3.49
3.88 / 3.47
COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min)
High
NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm)
Width
50
50
50
50
210 / 170 / 170
210 / 170 / 170
210 / 210 / 170
210 / 210 / 210
64.5
64.5
65
65
250 + 215 + 200
250 + 215 + 215
250 + 250 + 215
250 + 250 + 250
1220 + 920 + 920
1220 + 920 + 920
1220 + 1220 + 920
1220 + 1220 + 1220
Depth
760
760
760
760
Height
1710
1710
1710
1710
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
3
3
3
3
8/8/8
8/8/8
8/8/8
8/8/8
RUNNING CURRENT (A) Heating
46.4
51.2
52.7
55.7
Cooling
47.1
49.6
52.2
55.2
32 / 25 / 20
32 / 25 / 25
32 / 32 / 25
32 / 32 / 32
4 + earth
4 + earth
4 + earth
4 + earth
(1650mm without legs) ELECTRICAL SUPPLY PHASE STARTING CURRENT (A)
FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores
PUHY-P1100YSJM-A Side View
>
Front View
>
Y Series Standard (38-44hp)
MODEL REFERENCE
PUHY-P950-1100YSJM-A Piping Restrictions TOTAL PIPING LENGTH
1000m max
FURTHEST PIPING LENGTH
165m max
FURTHEST PIPING LENGTH AFTER 1st BRANCH
40m max
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
50m max (40m max if outdoor installed below)
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
15m max
Page 164
Page 165
Dimensions
Heat Pump Outdoor Unit
PUHY-P1150, 1200YSJM-A
Improved for even higher efficiency Side View
The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained. I I I I I I I I
I
>
Front View
>
Wrap around coil for improved energy efficiency Choice of Branch Pipe or Header Pipe feeds to indoor units Energy-saving inverter driven outdoor compressor units with very low start currents No requirement for plant rooms or bulky service shafts Weight and size reduction compared to YGM-A models Improved pipe run of 165m, with a total system pipe length of 1000m 100% inverter control High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants High Performance Heating Mode for low ambient conditions
Technical Information
City Multi Range
Y Series Standard (46-50hp)
PUHY-P1250YSJM-A
Y SERIES STANDARD OUTDOOR UNITS 46-50hp CAPACITY (kW)
POWER INPUT (kW)
PUHY-P1150YSJM-A
PUHY-P1200YSJM-A
PUHY-P1250YSJM-A
Heating (nominal)
145.0
150.0
156.5
Cooling (nominal)
130.0
136.0
140.0
High Performance Heating (UK)
137.8
142.5
148.7
COP Priority Heating (UK)
127.6
132.0
137.7
Cooling (UK)
119.6
125.1
128.8
Heating (nominal)
37.27
39.26
40.86
Cooling (nominal)
38.34
40.84
42.94
High Performance Heating (UK)
49.57
52.22
54.34
COP Priority Heating (UK)
34.29
36.12
37.59
Cooling (UK)
23.39
24.91
26.19
3.89 / 3.39
3.82 / 3.33
3.83 / 3.26
COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min)
High
50
50
50
370 / 210 / 210
370 / 210 / 210
370 / 370 / 210
NOISE (dBA)
65.5
66
66
WEIGHT (kg)
290 + 250 + 250
290 + 250 + 250
290 + 290 + 250 1750 + 1750 + 1220
DIMENSIONS (mm)
Width
1750 + 1220 + 1220
1750 + 1220 + 1220
Depth
760
760
760
Height
1710
1710
1710
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
3
3
3
8/8/8
8/8/8
8/8/8
RUNNING CURRENT (A) Heating
57.6
60.6
63.1
Cooling
59.2
63.1
66.3
40 / 32 / 32
40 / 32 / 32
40 / 40 / 32
4 + earth
4 + earth
4 + earth
(1650mm without legs) ELECTRICAL SUPPLY PHASE STARTING CURRENT (A)
FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores
Side View
>
Front View
>
Y Series Standard (46-50hp)
MODEL REFERENCE
PUHY-P1150-1250YSJM-A Piping Restrictions TOTAL PIPING LENGTH
1000m max
FURTHEST PIPING LENGTH
165m max
FURTHEST PIPING LENGTH AFTER 1st BRANCH
40m max
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
50m max (40m max if outdoor installed below)
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
15m max
Page 166
Page 167
Dimensions
Heat Pump Outdoor Unit
PUHY-EP200, 250, 300YJM-A
Improved for even higher efficiency
PUHY-EP200YJM-A schematic is the same as PUHY-P200, 250, 300YJM-A on page 158 PUHY-EP250YJM-A schematic is the same as PUHY-P350, 400YJM-A on page 158 PUHY-EP300YJM-A schematic is the same as PUHY-P450YJM-A on page 158
The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained. I I I I I I I I
I
PUHY-EP400YSJM-A
Highest ever COP’s / EER’s due to new higher efficiency inverter technology and wrap around coil Choice of Branch Pipe or Header Pipe feeds to indoor units Energy-saving inverter driven outdoor compressor units with very low start currents No requirement for plant rooms or bulky service shafts Weight and size reduction compared to YGM-A models Improved pipe run of 165m, with a total system pipe length of 1000m 100% inverter control High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants High Performance Heating Mode for low ambient conditions
Side View
>
Front View
>
Front View
>
City Multi Range
Y Series High COP (8-18hp)
Technical Information Y SERIES HIGH COP OUTDOOR UNITS 8-18hp CAPACITY (kW)
POWER INPUT (kW)
PUHY-EP200YJM-A
PUHY-EP250YJM-A
PUHY-EP300YJM-A
PUHY-EP400YSJM-A
PUHY-EP450YSJM-A
Heating (nominal)
25.0
31.5
37.5
50.0
56.0
Cooling (nominal)
22.4
28.0
33.5
45.0
50.0
High Performance Heating (UK)
25.0
31.5
35.6
47.5
50.7
COP Priority Heating (UK)
22.8
28.7
32.3
43.0
48.7
Cooling (UK)
21.3
26.6
31.5
42.3
46.0
Heating (nominal)
5.54
7.15
8.37
11.41
12.90
Cooling (nominal)
5.09
6.73
8.03
10.34
11.87
High Performance Heating (UK)
6.98
9.01
11.22
15.29
14.71
COP Priority Heating (UK)
5.48
7.08
8.12
11.07
11.74
Cooling (UK) COP / EER (nominal)
2.93
3.87
5.18
6.67
7.48
4.51 / 4.40
4.40 / 4.16
4.48 / 4.17
4.38 / 4.35
4.34 / 4.21
MAX No. OF CONNECTABLE INDOOR UNITS
17
21
26
35
39
AIRFLOW (m3/min)
170
210
370
170 / 170
210 / 170
High
NOISE (dBA)
57
60
61
60
62
WEIGHT (kg)
200
250
290
200 + 200
250 + 200 1220 + 920
DIMENSIONS (mm) (1650mm without legs)
Width
920
1220
1750
920 + 920
Depth
760
760
760
760
760
Height
1710
1710
1710
1710
1710 380-415v, 50Hz
ELECTRICAL SUPPLY
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
PHASE
3
3
3
3
3
STARTING CURRENT (A)
8
8
8
8/8
8/8
RUNNING CURRENT (A) Heating
8.5
11.0
12.9
17.6
19.9
Cooling
7.8
10.4
12.4
15.9
18.3
20
20
25
20 / 20
20 / 20
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores
PUHY-EP450YSJM-A Side View
>
Y Series High COP (8-18hp)
MODEL REFERENCE
PUHY-EP200-450Y(S)JM-A Piping Restrictions TOTAL PIPING LENGTH
1000m max
FURTHEST PIPING LENGTH
165m max
FURTHEST PIPING LENGTH AFTER 1st BRANCH
40m max
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
50m max (40m max if outdoor installed below)
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
15m max
Page 168
Page 169
Dimensions
Heat Pump Outdoor Unit
PUHY-EP500YSJM-A Side View
Improved for even higher efficiency
>
Front View
>
Front View
>
Front View
>
The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained. I
Highest ever COP’s / EER’s due to new higher efficiency inverter technology and wrap around coil
I
Choice of Branch Pipe or Header Pipe feeds to indoor units
I
Energy-saving inverter driven outdoor compressor units with very low start currents
I
No requirement for plant rooms or bulky service shafts
I
Weight and size reduction compared to YGM-A models
I
Improved pipe run of 165m, with a total system pipe length of 1000m
I
100% inverter control
I
High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants
I
High Performance Heating Mode for low ambient conditions
City Multi Range
Y Series High COP (20-24hp)
PUHY-EP550YSJM-A Side View
>
Technical Information Y SERIES HIGH COP OUTDOOR UNITS 20-24hp CAPACITY (kW)
POWER INPUT (kW)
PUHY-EP500YSJM-A
PUHY-EP550YSJM-A
PUHY-EP600YSJM-A
Heating (nominal)
63.0
69.0
76.5
Cooling (nominal)
56.0
63.0
69.0
High Performance Heating (UK)
57.0
62.4
69.2
COP Priority Heating (UK)
54.8
60.0
66.6
Cooling (UK)
51.5
58.0
63.5
Heating (nominal)
14.28
15.78
17.30
Cooling (nominal)
13.30
15.36
16.82
High Performance Heating (UK)
16.28
17.99
19.72
COP Priority Heating (UK)
12.99
14.36
15.74
Cooling (UK)
8.38
9.68
10.60
4.41 / 4.21
4.37 / 4.10
4.42 / 4.10
43
47
50 370 / 370
COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min)
High
370 / 170
370 / 210
NOISE (dBA)
62.5
63.5
64
WEIGHT (kg)
290 + 200
290 + 250
290 + 290 1750 + 1750
DIMENSIONS (mm)
Width
1750 + 920
1750 + 1220
Depth
760
760
760
Height
1710
1710
1710
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
3
3
3
8/8
8/8
8/8
RUNNING CURRENT (A) Heating
22.0
24.3
26.7
Cooling
20.5
23.7
26.0
25 / 20
25 / 20
25 / 25
4 + earth
4 + earth
4 + earth
(1650mm without legs) ELECTRICAL SUPPLY PHASE STARTING CURRENT (A)
FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores
PUHY-EP600YSJM-A Side View
>
Y Series High COP (20-24hp)
MODEL REFERENCE
PUHY-EP500-600YSJM-A Piping Restrictions TOTAL PIPING LENGTH
1000m max
FURTHEST PIPING LENGTH
165m max
FURTHEST PIPING LENGTH AFTER 1st BRANCH
40m max
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
50m max (40m max if outdoor installed below)
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
15m max
Page 170
Page 171
Dimensions
Heat Pump Outdoor Unit
PUHY-EP650YSJM-A Side View
Improved for even higher efficiency
>
Front View
>
The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained. Highest ever COP’s / EER’s due to new higher efficiency inverter technology and wrap around coil I Choice of Branch Pipe or Header Pipe feeds to indoor units I Energy-saving inverter driven outdoor compressor units with very low start currents I No requirement for plant rooms or bulky service shafts I Weight and size reduction compared to YGM-A models I Improved pipe run of 165m, with a total system pipe length of 1000m I 100% inverter control I High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants I High Performance Heating Mode for low ambient conditions I
City Multi Range
Y Series High COP (26-30hp)
PUHY-EP700YSJM-A Side View
>
Front View
>
Technical Information Y SERIES HIGH COP OUTDOOR UNITS 26-30hp CAPACITY (kW)
POWER INPUT (kW)
PUHY-EP650YSJM-A
PUHY-EP700YSJM-A
PUHY-EP750YSJM-A
Heating (nominal)
81.5
88.0
95.0
Cooling (nominal)
73.0
80.0
85.0
High Performance Heating (UK)
73.8
88.0
95.0
COP Priority Heating (UK)
70.9
76.6
82.7
Cooling (UK)
67.2
73.6
78.2
Heating (nominal)
18.56
20.00
21.93
Cooling (nominal)
17.46
19.13
20.43
High Performance Heating (UK)
21.16
25.20
27.63
COP Priority Heating (UK)
16.89
18.60
20.39
Cooling (UK)
11.00
12.34
13.18
4.39 / 4.18
4.40 / 4.18
4.33 / 4.16
50
50
50
COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min)
High
210 / 170 / 170
370 / 170 / 170
370 / 210 / 170
NOISE (dBA)
63
63.5
64.5
WEIGHT (kg)
250 + 200 + 200
290 + 200 + 200
290 + 250 + 200 1750 + 1220 + 920
DIMENSIONS (mm) (1650mm without legs)
Width
1220 + 920 + 920
1750 + 920 + 920
Depth
760
760
760
Height
1710
1710
1710
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
3
3
3
8/8/8
8/8/8
8/8/8
Heating
28.6
30.9
33.8
Cooling
26.9
29.5
31.5
20 / 20 / 20
25 / 20 / 20
25 / 20 / 20
4 + earth
4 + earth
4 + earth
ELECTRICAL SUPPLY PHASE STARTING CURRENT (A) RUNNING CURRENT (A)
FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores
PUHY-EP750YSJM-A Side View
>
Front View
>
Y Series High COP (26-30hp)
MODEL REFERENCE
PUHY-EP650-750YSJM-A Piping Restrictions TOTAL PIPING LENGTH
1000m max
FURTHEST PIPING LENGTH
165m max
FURTHEST PIPING LENGTH AFTER 1st BRANCH
40m max
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
50m max (40m max if outdoor installed below)
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
15m max
Page 172
Page 173
Dimensions
Heat Pump Outdoor Unit
PUHY-EP800YSJM-A
Improved for even higher efficiency
Side View
>
Front View
>
The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained. Highest ever COP’s / EER’s due to new higher efficiency inverter technology and wrap around coil I Choice of Branch Pipe or Header Pipe feeds to indoor units I Energy-saving inverter driven outdoor compressor units with very low start currents I No requirement for plant rooms or bulky service shafts I Weight and size reduction compared to YGM-A models I Improved pipe run of 165m, with a total system pipe length of 1000m I 100% inverter control I High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants I High Performance Heating Mode for low ambient conditions I
City Multi Range
Y Series High COP (32-36hp)
PUHY-EP850YSJM-A Side View
>
Front View
>
Technical Information Y SERIES HIGH COP OUTDOOR UNITS 32-36hp CAPACITY (kW)
POWER INPUT (kW)
PUHY-EP800YSJM-A
PUHY-EP850YSJM-A
PUHY-EP900YSJM-A
Heating (nominal)
100.0
108.0
113.0
Cooling (nominal)
90.0
96.0
101.0
High Performance Heating (UK)
100.0
102.6
107.4
COP Priority Heating (UK)
87.0
95.0
99.4
Cooling (UK)
82.8
88.3
92.9
Heating (nominal)
22.77
24.65
25.50
Cooling (nominal)
21.63
23.58
24.81
High Performance Heating (UK)
28.69
32.78
33.92
COP Priority Heating (UK)
21.18
22.68
23.46
Cooling (UK)
13.95
14.38
15.13
4.39 / 4.16
4.38 / 4.07
4.43 / 4.07
COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min)
High
50
50
50
370 / 370 / 170
370 / 370 / 210
370 / 370 / 370
NOISE (dBA)
65
65.5
66
WEIGHT (kg)
290 + 290 + 200
290 + 290 + 250
290 + 290 + 290
Width
1750 + 1750 + 920
1750 + 1750 + 1220
1750 +1750 + 1750
Depth
760
760
760
DIMENSIONS (mm) (1650mm without legs)
Height
ELECTRICAL SUPPLY
1710
1710
380-415v, 50Hz
380-415v, 50Hz
3
3
3
8/8/8
8/8/8
8/8/8
Heating
35.1
38.1
39.4
Cooling
33.4
36.4
38.3
25 / 25 / 20
25 / 25 / 20
25 / 25 / 25
4 + earth
4 + earth
4 + earth
PHASE STARTING CURRENT (A) RUNNING CURRENT (A)
1710 380-415v, 50Hz
FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores
PUHY-EP900YSJM-A Side View
>
Front View
Y Series High COP (32-36hp)
MODEL REFERENCE
>
PUHY-EP800-900YSJM-A Piping Restrictions TOTAL PIPING LENGTH
1000m max
FURTHEST PIPING LENGTH
165m max
FURTHEST PIPING LENGTH AFTER 1st BRANCH
40m max
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
50m max (40m max if outdoor installed below)
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
15m max
Page 174
Page 175
Dimensions
Heat Pump Outdoor Unit
PUHY-HP200, 250YHM-A
>
Upper View
Zubadan sets a new standard in performance The new City Multi Zubadan heat pumps achieve an excellent heating performance even when the outdoor air temperature is as low as -25ºC. I
Stable Heating Performance - Full heating capacity at -15°C - a 40% capacity improvement over the standard YJM-A model
I
Expanded Heating Operation - Will work effectively even when the outdoor ambient air temperature is -25°C
I
Stable Operation - Utilising the new Flash Injection Circuit the Zubadan models have reduced defrost times and can provide continuous heating for up to 250 mins
I
Quick Start-Up - Full heating capacity is achieved in about 20 mins, improving comfort levels
I
Energy-saving inverter driven outdoor compressor units with very low start currents
I
100% inverter control
I
High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants
Side View
>
Front View
>
City Multi Range
Y Series Zubadan (8-20hp)
Technical Information MODEL REFERENCE CAPACITY (kW)
POWER INPUT (kW)
PUHY-HP200YHM-A
PUHY-HP250YHM-A
PUHY-HP400YSHM-A
PUHY-HP500YSHM-A
Heating (nominal)
25.0
31.5
50.0
63.0
Cooling (nominal)
22.4
28.0
45.0
56.0
Heating (UK)
28.0
35.3
56.0
70.6
Cooling (UK)
19.9
24.9
40.1
49.8
Heating (nominal)
6.52
8.94
13.35
18.04
Cooling (nominal)
6.40
9.06
12.86
18.16
Heating (UK)
11.02
15.11
22.56
30.49
Cooling (UK)
4.99
7.07
10.03
14.16
3.83 / 3.50
3.52 / 3.09
3.74 / 3.49
3.49 / 3.08
COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS
17
21
34
43
AIRFLOW (m3/min)
225
225
225 / 225
225 / 225
56
57
59
60
High
NOISE (dBA) WEIGHT (kg) DIMENSIONS (mm) (1650mm without legs)
220
220
220 + 220
220 + 220
Width
920
920
920 + 920
920 + 920
Depth
760
760
760
760
Height
1710
1710
1710
1710 380-415v, 50Hz
ELECTRICAL SUPPLY
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
PHASE
3
3
3
3
STARTING CURRENT (A)
8
8
8/8
8/8
Heating
10.0
13.8
20.6
27.8
Cooling
9.8
14.0
19.8
28.0
32
32
32 / 32
32 / 32
RUNNING CURRENT (A)
FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores OPERATING RANGE (Outdoor temp ºC) Heating
4 + earth
4 + earth
4 + earth
4 + earth
-25 - 15.5ºC
-25 - 15.5ºC
-25 - 15.5ºC
-25 - 15.5ºC
PUHY-HP400, 500YSHM-A
Side View
>
Front View
Upper View
>
> Y Series Zubadan (8-20hp)
Y SERIES ZUBADAN OUTDOOR UNITS 8-20hp
PUHY-HP200-500Y(S)HM-A Piping Restrictions TOTAL PIPING LENGTH
300m max
FURTHEST PIPING LENGTH
150m max
FURTHEST PIPING LENGTH AFTER 1st BRANCH
40m max
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
50m max (40m max if outdoor installed below)
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
15m max
Page 176
Page 177
Dimensions
Heat Pump Outdoor Unit
PUHY-RP200, 250, 300, 350YJM-B
Upper View
>
Enables the replacement of VRF systems, whilst utilising existing R22 / R407c pipework. The latest VRF Replace Multi from Mitsubishi Electric is specifically designed for the maturing refurbishment sector, enabling the reuse of existing R22 / R407c pipework, whilst also allowing the upgrade to some of the most efficient systems available in the market. Replace Multi will clean the existing pipework during commissioning, removing any deposits and R22 mineral oil that would have ordinarily meant that new pipework would have been called for. The implications of this are significant savings on cost and time, whilst also minimising any potential disruption.
Side View
>
Front View
>
n Efficient use of existing resources - refrigerant piping, control and power wiring and less waste materials n Increased energy efficiency - up to 105% more efficient than an old Mitsubishi Electric R22 system (size 200) n Reduced installation costs of up to 55% n Reduced CO2 emissions and running cost savings of up to 45% n Reduced installation time with minimised disruption n Ability to replace many non Mitsubishi Electric systems n High Performance Heating Mode for low ambient conditions
City Multi Range
Y Series Replace Multi (8-26hp)
Technical Information Y SERIES REPLACE MULTI OUTDOOR UNITS 8-26hp
CAPACITY (kW)
Heating (nominal)
25.0
31.5
37.5
45.0
50.0
56.0
63.0
69.0
76.5
81.5
Cooling (nominal)
22.4
28.0
33.5
40.0
45.0
50.0
56.0
63.0
69.0
73.0
High Performance Heating (UK)
25.0
31.5
36.0
43.2
48.0
53.8
60.5
66.2
73.4
78.2
COP Priority Heating (UK)
22.8
28.7
32.6
39.2
43.5
48.7
54.8
60.0
66.6
70.9
Cooling (UK)
19.9
24.9
31.5
37.6
42.3
46.0
51.5
58.0
63.5
67.2
POWER INPUT (kW) Heating (nominal)
5.69
7.22
9.42
12.60
11.38
12.81
14.44
16.62
19.22
21.73
Cooling (nominal)
5.68
7.62
8.98
11.79
11.87
13.77
15.68
17.50
18.59
21.09
High Performance Heating (UK)
7.34
9.31
12.43
16.63
14.57
16.40
18.48
21.27
24.60
27.81
COP Priority Heating (UK)
5.63
7.15
9.14
12.22
11.04
11.66
13.14
15.12
17.49
19.77
Cooling (UK)
4.43
5.94
7.36
9.67
9.73
9.64
10.98
12.25
13.01
14.76
4.39 / 3.94
4.36 / 3.67
3.98 / 3.73
3.57 / 3.39
4.39 / 3.79
4.37 / 3.63
4.36 / 3.57
4.15 / 3.60
3.98 / 3.71
3.75 / 3.46
COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS
17
21
26
30
32
32
32
32
32
32
AIRFLOW (m3/min)
185
185
185
185
185 / 185
185 / 185
185 / 185
185 / 185
185 / 185
185 / 185
High
NOISE (dBA)
56
57
59
60
59
59.5
60
61
62
62.5
WEIGHT (kg)
230
255
255
255
230 + 230
255 + 230
255 + 255
255 + 255
255 + 255
255 + 255 920 + 920
DIMENSIONS (mm) (1650mm without legs)
Width
920
920
920
920
920 + 920
920 + 920
920 + 920
920 + 920
920 + 920
Depth
760
760
760
760
760
760
760
760
760
760
Height
1710
1710
1710
1710
1710
1710
1710
1710
1710
1710
ELECTRICAL SUPPLY
Upper View
Side View
>
Front View
>
>
380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz
PHASE
3
3
3
3
3
3
3
3
3
3
STARTING CURRENT (A)
8
8
8
8
8+8
8+8
8+8
8+8
8+8
8+8
Heating
8.7
12.1
15.2
20.2
17.5
20.7
24.2
27.3
31.1
35.0
Cooling
8.7
12.7
14.4
18.9
18.3
22.2
26.2
28.7
30.8
34.0
20
20
25
32
20 + 20
20 + 20
20 + 20
25 + 20
25 + 25
32 + 25
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
RUNNING CURRENT (A)
PUHY-RP400, 450, 500, 550, 600, 650YSJM-B
Y Series Replace Multi (8-26hp)
PUHYPUHYPUHYPUHYPUHYPUHYPUHYPUHYPUHYPUHYRP200YJM-B RP250YJM-B RP300YJM-B RP350YJM-B RP400YSJM-B RP450YSJM-B RP500YSJM-B RP550YSJM-B RP600YSJM-B RP650YSJM-B
MODEL REFERENCE
FUSE RATING (MCB sizes BS EN 60947-2) - HRC (A) MAINS CABLE No. Cores
PUHY-RP200-650Y(S)JM-B Piping Restrictions TOTAL PIPING LENGTH FURTHEST PIPING LENGTH FURTHEST PIPING LENGTH AFTER 1st BRANCH
300m max (250m for size 600-650) 120m max 40m max
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
50m max (40m max if outdoor installed below)
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
15m max
Page 178
Page 179
Dimensions
Heat Pump Outdoor Unit
PUHY-RP700, 750, 800, 850, 900YSJM-B
Enables the replacement of VRF systems, whilst utilising existing R22 / R407c pipework. Upper View
The latest VRF Replace Multi from Mitsubishi Electric is specifically designed for the maturing refurbishment sector, enabling the reuse of existing R22 / R407c pipework, whilst also allowing the upgrade to some of the most efficient systems available in the market.
>
Replace Multi will clean the existing pipework during commissioning, removing any deposits and R22 mineral oil that would have ordinarily meant that new pipework would have been called for. The implications of this are significant savings on cost and time, whilst also minimising any potential disruption. I
Tried and tested technology thatâ&#x20AC;&#x2122;s been employed for over 5 years
I
Efficient use of existing resources - refrigerant piping, control and power wiring and less waste materials
I
Reduced installation costs of up to 55%
I
Reduced CO2 emissions and increased energy efficiency resulting in running cost savings of up to 45%
I
Reduced installation time with minimised disruption
I
Ability to replace many non Mitsubishi Electric systems
I
High Performance Heating Mode for low ambient conditions
Side View
>
Front View
>
City Multi Range
Y Series Replace Multi (28-36hp)
Technical Information
MODEL REFERENCE
PUHY-RP700YSJM-B
PUHY-RP750YSJM-B
PUHY-RP800YSJM-B
PUHY-RP850YSJM-B
PUHY-RP900YSJM-B
Heating (nominal)
88.0
95.0
100.0
108.0
113.0
Cooling (nominal)
80.0
85.0
90.0
96.0
101.0
High Performance Heating (UK)
84.5
91.2
96.0
103.7
108.5
COP Priority Heating (UK)
76.6
82.7
87.0
94.0
98.3
Cooling (UK)
73.6
78.2
82.8
88.3
92.9
POWER INPUT (kW) Heating (nominal)
20.13
21.78
23.75
26.47
28.39
Cooling (nominal)
22.22
24.14
25.49
27.11
28.29
High Performance Heating (UK)
26.57
28.75
31.35
34.15
36.62
COP Priority Heating (UK)
18.72
20.26
22.09
24.09
25.83
Cooling (UK)
18.66
20.28
21.41
22.77
23.76
4.37 / 3.60
4.36 / 3.52
4.21 / 3.53
4.08 / 3.54
3.98 / 3.57
CAPACITY (kW)
COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min)
High
32
32
32
32
32
185 / 185 / 185
185 / 185 / 185
185 / 185 / 185
185 / 185 / 185
185 / 185 / 185
NOISE (dBA)
61.5
62
62.5
63.5
64
WEIGHT (kg)
255 + 255 + 230
255 + 255 + 255
255 + 255 + 255
255 + 255 + 255
255 + 255 + 255 920 + 920 + 920
DIMENSIONS (mm) (1650mm without legs)
Width
920 + 920 + 920
920 + 920 + 920
920 + 920 + 920
920 + 920 + 920
Depth
760
760
760
760
760
Height
1710
1710
1710
1710
1710
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
3
3
3
3
3
8+8+8
8+8+8
8+8+8
8+8+8
8+8+8
Heating
33.0
36.5
39.3
43.2
45.9
Cooling
36.4
39.7
42.0
44.1
45.7
20 + 20 + 20
20 + 20 + 20
25 + 20 + 20
25 + 25 + 20
25 + 25 + 25
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
ELECTRICAL SUPPLY PHASE STARTING CURRENT (A) RUNNING CURRENT (A)
FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores
Y Series Replace Multi (28-36hp)
Y SERIES REPLACE MULTI OUTDOOR UNITS 28-36hp
PUHY-RP700-900YSJM-B Piping Restrictions TOTAL PIPING LENGTH
250m max
FURTHEST PIPING LENGTH
100m max
FURTHEST PIPING LENGTH AFTER 1st BRANCH
40m max
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
50m max (40m max if outdoor installed below)
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
15m max
Page 180
Page 181
Dimensions
Heat Pump, Water Cooled Condensing Unit
PQHY-P200, 250, 300YHM-A
The WY Series has all the benefits of the Y Series using water cooled condensing units. It is also able to produce heat recovery via the water circuit between heat source units, making for a very economical system. Like the YJM-A air source versions, the water cooled units now benefit from a modular design approach. A twinning kit is required for double combinations. I
High COPs possible thanks to increased efficiency and careful control of the system, allowing the largest operational water circuit temperature band ever
I
40% height reduction compared to previous YGM-A models
I
Combining WY with waste heat energy provides unique application solutions
I
Up to 50 indoor units can now be connected to each condensing unit
I
Single inverter compressor
I
Improved pipe run of 165m with a total system pipe length of up to 500m
I
High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants
I
Able to operate with closed loop ground source water temperatures, bore hole and slinky applications are now possible
I
Easy maintenance - front panel access to all PCBâ&#x20AC;&#x2122;s
I
Condensing units must be situated indoors
Upper View
Front View
>
>
Right Side View
>
City Multi Range
WY Series (8-24hp)
Technical Information
PQHY-P400, 450, 500, 550, 600YSHM-A
WY SERIES HEAT SOURCE UNITS - 8-24hp MODEL REFERENCE
POWER INPUT (kW)
PQHY-P200YHM-A PQHY-P250YHM-A PQHY-P300YHM-A PQHY-P400YSHM-A PQHY-P450YSHM-A PQHY-P500YSHM-A PQHY-P550YSHM-A PQHY-P600YSHM-A Heating (nominal)
25.0
31.5
37.5
50.0
56.0
63.0
69.0
Cooling (nominal)
22.4
28.0
33.5
45.0
50.0
56.0
63.0
69.0
Heating (nominal)
4.12
5.80
8.15
8.65
10.42
12.06
14.65
17.12
Cooling (nominal) COP / EER (nominal)
76.5
3.92
5.45
7.36
8.25
9.84
11.45
13.46
15.48
6.06 / 5.71
5.43 / 5.13
4.60 / 4.55
5.78 / 5.45
5.37 / 5.08
5.22 / 4.89
4.70 / 4.68
4.46 / 4.45 50
MAX No. OF CONNECTABLE INDOOR UNITS
17
21
26
34
39
43
47
NOISE (dBA)
47
49
50
50
51
52
52.5
53
WEIGHT (kg)
195
195
195
195 + 195
195 + 195
195 + 195
195 + 195
195 + 195
Width
880
880
880
880 + 880
880 + 880
880 + 880
880 + 880
880 + 880
Depth
550
550
550
550
550
550
550
550
Height
1160
1160
1160
1160
1160
1160
1160
1160
DIMENSIONS (mm)
(1100 without legs) ELECTRICAL SUPPLY
380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz
380-415v, 50Hz
3
3
3
3
3
3
3
3
STARTING CURRENT (A)
8
8
8
8/8
8/8
8/8
8/8
8/8
Heating
6.3
8.9
12.5
13.3
16.1
18.6
22.6
26.4
Cooling
6.0
8.4
11.3
12.7
15.2
17.6
20.8
23.9
20
20
20
20 / 20
20 / 20
20 / 20
20 / 20
20 / 20
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores
>
Front View
>
380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz
PHASE
RUNNING CURRENT (A)
Left Side View
WY Series (8-24hp)
CAPACITY (kW)
PQHY-P200-600Y(S)HM-A Piping Restrictions TOTAL PIPING LENGTH FURTHEST PIPING LENGTH FURTHEST PIPING LENGTH AFTER 1st BRANCH
300m max for sizes 200-300 / 500m max for sizes 400-600 165m max 40m max
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
50m max (40m max if outdoor installed below)
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
15m max
Page 182
Page 183
Dimensions
Heat Pump, Water Cooled Condensing Unit
PQHY-P650, 700, 750, 800, 850, 900YSHM-A
The WY Series has all the benefits of the Y Series using water cooled condensing units. It is also able to produce heat recovery via the water circuit between heat source units, making for a very economical system. Like the YJM-A air source versions, the water cooled units now benefit from a modular design approach. A twinning kit is required. I
High COPs possible thanks to increased efficiency and careful control of the system, allowing the largest operational water circuit temperature band ever
I
40% height reduction compared to previous YGM-A models
I
Combining WY with waste heat energy provides unique application solutions
I
Up to 50 indoor units can now be connected to each condensing unit
I
Single inverter compressor
I
Improved pipe run of 165m with a total system pipe length of up to 500m
I
High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants
I
Able to operate with closed loop ground source water temperatures, bore hole and slinky applications are now possible
I
Easy maintenance front panel access to all PCBâ&#x20AC;&#x2122;s
I
Condensing units must be situated indoors
Upper View
Left Side View
>
Front View
>
>
City Multi Range
WY Series (26-36hp)
Technical Information MODEL REFERENCE CAPACITY (kW)
POWER INPUT (kW)
PQHY-P650YSHM-A
PQHY-P700YSHM-A
PQHY-P750YSHM-A
PQHY-P800YSHM-A
PQHY-P850YSHM-A
PQHY-P900YSHM-A
Heating (nominal)
81.5
88.0
95.0
100.0
108.0
113.0
Cooling (nominal)
73.0
80.0
85.0
90.0
96.0
101.0
Heating (nominal)
14.74
16.51
18.27
20.74
23.21
25.67
Cooling (nominal)
13.96
15.58
17.19
19.18
21.20
23.22
5.52 / 5.22
5.33 / 5.13
5.19 / 4.94
4.82 / 4.69
4.65 / 4.52
4.40 / 4.34 50
COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS
50
50
50
50
50
NOISE (dBA)
53
53.5
54
54
54.5
55
WEIGHT (kg)
195 + 195 + 195
195 + 195 + 195
195 + 195 + 195
195 + 195 + 195
195 + 195 + 195
195 + 195 + 195
Width
880 + 880 + 880
880 + 880 + 880
880 + 880 + 880
880 + 880 + 880
880 + 880 + 880
880 + 880 + 880
Depth
550
550
550
550
550
550
Height
1160
1160
1160
1160
1160
1160
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
3
3
3
3
3
3
8/8/8
8/8/8
8/8/8
8/8/8
8/8/8
8/8/8
Heating
22.7
25.5
28.2
32.0
35.8
39.6
Cooling
21.5
24.0
26.5
29.6
32.7
35.8
20 / 20 / 20
20 / 20 / 20
20 / 20 / 20
20 / 20 / 20
20 / 20 / 20
20 / 20 / 20
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
DIMENSIONS (mm)
(1100 without legs) ELECTRICAL SUPPLY PHASE STARTING CURRENT (A) RUNNING CURRENT (A)
FUSE RATING (BS88) - HRC (A) MAINS CABLE No. Cores
WY Series (26-36hp)
WY SERIES HEAT SOURCE UNITS - 26-36hp
PQHY-P650-900YSHM-A Piping Restrictions TOTAL PIPING LENGTH
500m max
FURTHEST PIPING LENGTH
165m max
FURTHEST PIPING LENGTH AFTER 1st BRANCH
40m max
BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT
50m max (40m max if outdoor installed below)
BETWEEN INDOOR AND INDOOR UNITS - HEIGHT
15m max
Page 184
Page 185
Dimensions
Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit
PURY-P200, 250, 300YJM-A
Improved for even higher efficiency
Side View
>
Front View
>
Upper View
>
>
Upper View
>
Upper View
>
Throughout the year, many buildings require cooling in some areas and heating in others - even in adjacent rooms. The outstanding City Multi R2 system meets this requirement by distributing surplus heat from cooling operations (and vice versa) to rooms where it is needed. This efficiency can result in energy savings of up to 30% over conventional systems. I
New higher efficiency inverter technology, with low start currents and wrap around coil for added efficiency
I
Up to 45 indoor units connected to each outdoor unit
I
Easy to install unique 2-pipe technology means minimal disruption, quicker installation and less connections than 3 pipe equivalents
I
Weight and size reduction compared to YGM-A models
I
Improved pipe run of 165m with a total system pipe length of up to 600m
I
100% inverter control
I
High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants
I
High Performance Heating Mode for low ambient conditions
City Multi Range
R2 Series Standard (8-18hp)
PURY-P350, 400YJM-A Side View
>
Front View
Technical Information R2 SERIES STANDARD OUTDOOR UNITS 8-18hp MODEL REFERENCE
PURY-P200YJM-A PURY-P250YJM-A PURY-P300YJM-A PURY-P350YJM-A PURY-P400YJM-A PURY-P450YJM-A 25.0
31.5
37.5
45.0
50.0
56.0
Cooling (nominal)
22.4
28.0
33.5
40.0
45.0
50.0
High Performance Heating (UK)
25.0
31.5
35.6
42.8
47.5
50.7
COP Priority Heating (UK)
22.8
28.7
32.3
38.7
43.0
48.7
Cooling (UK)
21.3
26.6
31.5
37.6
42.3
46.0
POWER INPUT (kW) Heating (nominal)
5.69
7.32
8.78
10.89
12.75
14.58
Cooling (nominal)
5.18
7.05
8.67
11.33
13.55
14.49
High Performance Heating (UK)
7.17
9.22
11.77
14.59
17.09
16.62
COP Priority Heating (UK)
5.63
7.25
8.52
10.56
12.37
13.27
Cooling (UK) COP / EER (nominal)
2.98
4.05
5.59
7.31
8.74
9.13
4.39 / 4.32
4.30 / 3.97
4.27 / 3.86
4.13 / 3.53
3.92 / 3.32
3.84 / 3.45
MAX No. OF CONNECTABLE INDOOR UNITS
20
25
30
35
40
45
AIRFLOW (m3/min)
185
185
185
225
225
360
High
NOISE (dBA)
56
57
59
60
61
62
WEIGHT (kg)
240
240
245
270
270
320 1750
DIMENSIONS (mm) (1650mm without legs)
Width
920
920
920
1220
1220
Depth
760
760
760
760
760
760
Height
1710
1710
1710
1710
1710
1710
ELECTRICAL SUPPLY
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
PHASE
3
3
3
3
3
3
STARTING CURRENT (A)
8
8
8
8
8
8
Heating
8.7
11.3
13.5
16.8
19.7
22.5
Cooling
8.0
10.8
13.4
17.5
20.9
22.3
20
20
25
32
40
40
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
RUNNING CURRENT (A)
FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores
PURY-P450YJM-A Side View
>
Front View
>
R2 Series Standard (8-18hp)
Heating (nominal)
CAPACITY (kW)
Note: For piping restrictions for PURY-P200-450YJM-A please see page 196 Page 186
Page 187
Dimensions
Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit
PURY-P450YSJM-A1 / PURY-P500, 550, 600YSJM-A
Improved for even higher efficiency Side View
Throughout the year, many buildings require cooling in some areas and heating in others - even in adjacent rooms. The outstanding City Multi R2 system meets this requirement by distributing surplus heat from cooling operations (and vice versa) to rooms where it is needed. This efficiency can result in energy savings of up to 30% over conventional systems. I
New higher efficiency inverter technology, with low start currents and wrap around coil for added efficiency
I
Up to 50 indoor units connected to each outdoor unit
I
Easy to install unique 2-pipe technology means minimal disruption, quicker installation and less connections than 3 pipe equivalents
I
Weight and size reduction compared to YGM-A models
I
Improved pipe run of 165m with a total system pipe length of up to 950m
I
100% inverter control
I
High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants
I
High Performance Heating Mode for low ambient conditions
>
Front View
>
City Multi Range
R2 Series Standard (18-28hp)
PURY-P650, 700YSJM-A
Technical Information
Side View
>
Front View
>
R2 SERIES STANDARD OUTDOOR UNITS 18-28hp MODEL REFERENCE
56.0
63.0
69.0
76.5
81.5
88.0
Cooling (nominal)
50.0
56.0
63.0
69.0
73.0
80.0
High Performance Heating (UK)
50.7
57.0
62.4
69.2
73.8
88.0
COP Priority Heating (UK)
48.7
54.8
60.0
66.6
70.9
76.6
Cooling (UK)
46.0
51.5
58.0
63.5
67.2
73.6
POWER INPUT (kW) Heating (nominal)
13.30
15.10
16.95
19.07
20.47
22.33
Cooling (nominal)
12.50
14.85
17.30
19.65
21.53
23.95
High Performance Heating (UK)
15.16
17.21
19.32
21.74
23.34
28.14
COP Priority Heating (UK)
12.10
13.74
15.42
17.35
18.63
20.77
Cooling (UK)
7.88
9.36
10.90
12.38
13.56
15.45
4.21 / 4.00
4.17 / 3.77
4.07 / 3.64
4.01 / 3.51
3.98 / 3.39
3.94 / 3.34
COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min)
High
45
50
50
50
50
50
185 / 185
185 / 185
185 / 185
185 / 185
225 / 185
225 / 185
NOISE (dBA)
59.5
60
61
62
62.5
63
WEIGHT (kg)
240 + 240
240 + 240
245 + 240
245 + 245
270 + 245
270 + 245 1220 + 920
Width
920 + 920
920 + 920
920 + 920
920 + 920
1220 + 920
Depth
760
760
760
760
760
760
Height
1710
1710
1710
1710
1710
1710
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
3
3
3
3
3
3
8/8
8/8
8/8
8/8
8/8
8/8
RUNNING CURRENT (A) Heating
20.5
23.3
26.2
29.4
31.6
34.5
Cooling
19.3
22.9
26.7
30.3
33.2
37.0
20 / 20
20 / 20
25 / 20
25 / 25
32 / 25
40 / 25
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
DIMENSIONS (mm) (1650mm without legs) ELECTRICAL SUPPLY PHASE STARTING CURRENT (A)
FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores
R2 Series Standard (18-28hp)
PURY-P450YSJM-A1 PURY-P500YSJM-A PURY-P550YSJM-A PURY-P600YSJM-A PURY-P650YSJM-A PURY-P700YSJM-A
Heating (nominal)
CAPACITY (kW)
Note: For piping restrictions for PURY-P450-700YSJM-A(1) please see page 196 Page 188
Page 189
Dimensions
Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit
PURY-P750, 800YSJM-A Side View
Improved for even higher efficiency
>
Front View
>
Front View
>
Front View
>
Throughout the year, many buildings require cooling in some areas and heating in others - even in adjacent rooms. The outstanding City Multi R2 system meets this requirement by distributing surplus heat from cooling operations (and vice versa) to rooms where it is needed. This efficiency can result in energy savings of up to 30% over conventional systems. I
New higher efficiency inverter technology, with low start currents and wrap around coil for added efficiency
I
Up to 50 indoor units connected to each outdoor unit
I
Easy to install unique 2-pipe technology means minimal disruption, quicker installation and less connections than 3 pipe equivalents
I
Weight and size reduction compared to YGM-A models
I
Improved pipe run of 165m with a total system pipe length of up to 950m
I
100% inverter control
I
High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants
I
High Performance Heating Mode for low ambient conditions
City Multi Range
R2 Series Standard (30-36hp)
PURY-P850YSJM-A Side View
>
Technical Information R2 SERIES STANDARD OUTDOOR UNITS 30-36hp PURY-P750YSJM-A
PURY-P800YSJM-A
PURY-P850YSJM-A
PURY-P900YSJM-A
Heating (nominal)
95.0
100.0
108.0
113.0
Cooling (nominal)
85.0
90.0
96.0
101.0
High Performance Heating (UK)
95.0
100.0
102.6
107.4
COP Priority Heating (UK)
82.7
87.0
95.0
99.4
Cooling (UK)
78.2
82.8
88.3
92.9
POWER INPUT (kW) Heating (nominal)
24.05
26.04
28.42
30.05
Cooling (nominal)
26.47
28.30
29.26
30.23
High Performance Heating (UK)
30.30
32.81
37.80
39.97
COP Priority Heating (UK)
22.37
24.22
26.15
27.65
Cooling (UK)
17.07
18.25
17.85
18.44
3.95 / 3.21
3.84 / 3.18
3.80 / 3.28
3.76 / 3.34
CAPACITY (kW)
COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min)
High
50
50
50
50
225 / 225
225 / 225
360 / 225
360 / 360
NOISE (dBA)
63.5
64
64.5
65
WEIGHT (kg)
270 + 270
270 + 270
320 + 270
320 + 320 1750 + 1750
Width
1220 + 1220
1220 + 1220
1750 + 1220
Depth
760
760
760
760
Height
1710
1710
1710
1710
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
3
3
3
3
8/8
8/8
8/8
8/8
RUNNING CURRENT (A) Heating
37.1
40.2
43.9
46.4
Cooling
40.9
43.7
45.2
46.7
40 / 32
40 / 40
40 / 40
40 / 40
4 + earth
4 + earth
4 + earth
4 + earth
DIMENSIONS (mm) (1650mm without legs) ELECTRICAL SUPPLY PHASE STARTING CURRENT (A)
FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores
PURY-P900YSJM-A Side View
>
R2 Series Standard (30-36hp)
MODEL REFERENCE
Note: For piping restrictions for PURY-P750-900YSJM-A please see page 196 Page 190
Page 191
Dimensions
Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit
PURY-EP200, 250, 300, 350YJM-A
Improved for even higher efficiency
PURY-EP200YJM-A schematic is the same as PURY-P200, 250, 300YJM-A on page 186
Throughout the year, many buildings require cooling in some areas and heating in others - even in adjacent rooms. The outstanding City Multi R2 system meets this requirement by distributing surplus heat from cooling operations (and vice versa) to rooms where it is needed. This efficiency can result in energy savings of up to 30% over conventional systems.
PURY-EP350YJM-A schematic is the same as PURY-P450YJM-A on page 186
PURY-EP250, 300YJM-A schematic is the same as PURY-P350, 400YJM-A on page 186
PURY-EP400YSJM-A
I
Highest ever COP’s / EER’s due to new high efficiency inverter technology and wrap around coil for added efficiency
I
Up to 50 indoor units connected to each outdoor unit
I
Easy to install unique 2-pipe technology means minimal disruption, quicker installation and less connections than 3 pipe equivalents
I
Weight and size reduction compared to YGM-A models
I
Improved pipe run of 165m with a total system pipe length of up to 750m
I
100% inverter control with low start currents
I
High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants
I
High Performance Heating Mode for low ambient conditions
Side View
>
Front View
>
City Multi Range
R2 Series High COP (8-20hp)
Technical Information
PURY-EP450, 500YSJM-A
R2 SERIES HIGH COP OUTDOOR UNITS 8-20hp MODEL REFERENCE
PURY-EP200YJM-A PURY-EP250YJM-A PURY-EP300YJM-A PURY-EP350YJM-A PURY-EP400YSJM-A PURY-EP450YSJM-A PURY-EP500YSJM-A
Heating (nominal)
25.0
31.5
37.5
45.0
50.0
56.0
63.0
Cooling (nominal)
22.4
28.0
33.5
40.0
45.0
50.0
56.0
High Performance Heating (UK)
25.0
31.5
35.6
42.8
47.5
50.7
57.0
48.7
54.8
COP Priority Heating (UK)
22.8
28.7
32.3
38.7
43.0
Cooling (UK)
21.3
26.6
31.5
37.6
42.3
46.0
51.5
POWER INPUT (kW) Heating (nominal)
5.56
7.15
8.60
10.58
11.36
12.87
14.38
Cooling (nominal)
5.07
6.76
8.25
10.28
10.41
11.99
13.62
High Performance Heating (UK)
7.01
9.01
11.52
14.18
15.22
14.67
16.39
COP Priority Heating (UK)
5.50
7.08
8.34
10.26
11.02
11.71
13.09
Cooling (UK)
2.92
3.89
5.32
6.63
6.71
7.55
8.58
4.49 / 4.41
4.40 / 4.14
4.36 / 4.06
4.25 / 3.89
4.40 / 4.32
4.35 / 4.17
4.38 / 4.11
COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS
20
25
30
35
40
45
50
AIRFLOW (m3/min)
185
225
225
360
185 / 185
225 / 185
225 / 185
High
NOISE (dBA)
57
60
60
61
60
62
62
WEIGHT (kg)
240
270
270
320
240 + 240
270 + 240
270 + 240 1220 + 920
DIMENSIONS (mm) (1650mm without legs)
Width
920
1220
1220
1750
920 + 920
1220 + 920
Depth
760
760
760
760
760
760
760
Height
1710
1710
1710
1710
1710
1710
1710 380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
PHASE
3
3
3
3
3
3
3
STARTING CURRENT (A)
8
8
8
8
8/8
8/8
8/8
RUNNING CURRENT (A) Heating
8.5
11.0
13.2
16.3
17.5
19.8
22.2
Cooling
7.8
10.4
12.7
15.8
16.0
18.5
21.0
20
20
25
32
20 / 20
20 / 20
25 / 20
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
ELECTRICAL SUPPLY
FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores
Side View
>
Front View
> R2 Series High COP (8-20hp)
CAPACITY (kW)
Note: For piping restrictions for PURY-EP200-500Y(S)JM-A please see page 196 Page 192
Page 193
Dimensions
Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit
PURY-EP550, 600YSJM-A Side View
Improved for even higher efficiency
>
Front View
>
Throughout the year, many buildings require cooling in some areas and heating in others - even in adjacent rooms. The outstanding City Multi R2 system meets this requirement by distributing surplus heat from cooling operations (and vice versa) to rooms where it is needed. This efficiency can result in energy savings of up to 30% over conventional systems. I
Highest ever COP’s / EER’s due to new high efficiency inverter technology and wrap around coil for added efficiency
I
Up to 50 indoor units connected to each outdoor unit
I
Easy to install unique 2-pipe technology means minimal disruption, quicker installation and less connections than 3 pipe equivalents
I
Weight and size reduction compared to YGM-A models
I
Improved pipe run of 165m with a total system pipe length of up to 800m
I
100% inverter control with low start currents
I
High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants
I
City Multi Range
R2 Series High COP (22-28hp)
PURY-EP650YSJM-A Side View
>
Front View
>
High Performance Heating Mode for low ambient conditions
Technical Information R2 SERIES HIGH COP OUTDOOR UNITS 22-28hp PURY-EP550YSJM-A
PURY-EP600YSJM-A
PURY-EP650YSJM-A
PURY-EP700YSJM-A
Heating (nominal)
69.0
76.5
81.5
88.0
Cooling (nominal)
63.0
69.0
73.0
80.0
High Performance Heating (UK)
62.4
69.2
73.8
88.0
COP Priority Heating (UK)
60.0
66.6
70.9
76.6
Cooling (UK)
58.0
63.5
67.2
73.6
POWER INPUT (kW) Heating (nominal)
15.93
17.38
19.73
22.05
Cooling (nominal)
15.40
16.87
19.01
21.22
High Performance Heating (UK)
18.16
19.81
22.49
27.78
COP Priority Heating (UK)
14.50
15.82
17.95
20.51
Cooling (UK)
9.70
10.63
11.98
13.69
4.33 / 4.09
4.40 / 4.09
4.13 / 3.84
3.99 / 3.77
CAPACITY (kW)
COP / EER (nominal) MAX No. OF CONNECTABLE INDOOR UNITS AIRFLOW (m3/min)
High
50
50
50
50
225 / 225
225 / 225
360 / 225
360 / 360
NOISE (dBA)
63
63
63.5
64
WEIGHT (kg)
270 + 270
270 + 270
320 + 270
320 + 320 1750 + 1750
DIMENSIONS (mm)
Width
1220 + 1220
1220 + 1220
1750 + 1220
Depth
760
760
760
760
Height
1710
1710
1710
1710
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
3
3
3
3
8/8
8/8
8/8
8/8
RUNNING CURRENT (A) Heating
24.6
26.8
30.4
34.0
Cooling
23.8
26.0
29.3
32.8
25 / 20
25 / 25
32 / 25
32 / 32
4 + earth
4 + earth
4 + earth
4 + earth
(1650mm without legs) ELECTRICAL SUPPLY PHASE STARTING CURRENT (A)
FUSE RATING (MCB sizes BS EN 60947-2) - (A) MAINS CABLE No. Cores
PURY-EP700YSJM-A Side View
>
Front View
>
R2 Series High COP (22-28hp)
MODEL REFERENCE
Note: For piping restrictions for PURY-EP550-700YSJM-A please see page 196 Page 194
Page 195
City Multi Range
R2 Series Piping Restrictions R2 SERIES PIPING RESTRICTIONS
TABLE 1: TOTAL PIPE LENGTH OUTDOOR MODEL
MAX LENGTH
P200, P250, P300, EP200 P350, P400, P450, EP250, EP300, EP350 P500, P550, EP400, EP450, EP500, EP550 P600, P650, EP600, EP650, EP700 P700, P750, P800, P850, P900
550m*1 600m*1 750m*1 800m*1 950m*1
1
*1 Please refer to Graph 1
R2 SERIES PIPING RESTRICTIONS
GRAPH 1: TOTAL PIPING LENGTH RESTRICTIONS
PIPING LENGTH (>1 BC CONTROLLER FOR 1 OUTDOOR UNIT)
ITEM
1000
Total Extended Pipe Length (m)
900 800 700
PURY-P700,750,800,850,900YSJM-A
600 PURY-P600,650YSJM-A, PURY-EP600,650,700YSJM-A PURY-P500,550YSJM-A, PURY-EP400,450,500,550YSJM-A
500 400
PURY-P350,400,450Y(S)JM-A(1), PURY-EP250,300,350YJM-A
300
PIPE SECTION A+B+C+D+E+a+b+c+d+e+f A+C+E+f A B+d or C+D+e or C+E+f H H1 h1 h2 h3
Total Piping Length Furthest Piping Length Length Between OU and BC Length Between Furthest IU and BC Height Between OU and IU (OU above IU) Height Between OU and IU (OU below IU) Height Between IU and BC Height Between IU and IU Height Between BC (Main or Sub) and BC (Sub)
MAX LENGTH (See Table 1) 165m 110m*1 60m*2 (40m) 50m 40m 15m 15m 15m
PURY-P200,250,300YJM-A, PURY-EP200YJM-A
*1 Please refer to Graph 1. *2 Height difference between BC controller and furthest indoor unit is zero.
200 100 0 10
20
30
40
50
60
70
80
90
100
110
Distance Between Outdoor Unit and BC Controller (m)
R2 SERIES PIPING RESTRICTIONS / EP600 or less 700 to P800 CMY-R100XLVBK: Outdoor unit EP650 and EP700 CMY-R200XLVBK: Outdoor unit P850 and P900
1
1
R2 SERIES PIPING RESTRICTIONS
R2 SERIES PIPING RESTRICTIONS
PIPING LENGTH (>1 BC CONTROLLER FOR 2 OUTDOOR UNITS)
PIPING LENGTH (1 BC CONTROLLER, NO SUB BC CONTROLLER)
ITEM Total Piping Length Furthest Piping Length Length Between OU and BC Length Between Furthest IU and BC Height Between OU and IU (OU above IU) Height Between OU and IU (OU below IU) Height Between IU and BC Height Between IU and IU *1 Please refer to Graph 1. *2 Height difference between BC controller and furthest indoor unit is zero.
R2 Series Piping Restrictions
1
PIPE SECTION A+B+a+b+c+d A+B+d A B+d H H1 h1 h2
MAX LENGTH (See Table 1) 165m 110m*1 60m*2 (40m) 50m 40m 15m 15m
PIPE SECTION
ITEM Total Piping Length Furthest Piping Length Length Between OU and BC Length Between Furthest IU and BC Height Between OU and IU (OU above IU) Height Between OU and IU (OU below IU) Height Between IU and BC Height Between IU and IU Height Between BC (Main or Sub) and BC (Sub) Length Between Main OU and Sub OU Height Between Main OU and Sub OU
F+G+H+A+B+C+D+E+a+b+c+d+e+f F(G)+A+C+E+f F(G)+A B+d or C+D+e or C+E+f H H1 h1 h2 h3 F+G or H h4
MAX LENGTH (See Table 1) 165m 110m*1 60m*2 (40m) 50m 40m 15m 15m 15m 5m 0.1m
*1 Please refer to Graph 1. *2 Height difference between BC controller and furthest indoor unit is zero.
Page 196
Page 197
Dimensions
Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit
PURY-RP200, 250, 300YJM-B
upper view
>
enables the replacement of vrF systems, whilst utilising existing r22 / r407c pipework. The latest VRF Replace Multi from Mitsubishi Electric is specifically designed for the maturing refurbishment sector, enabling the reuse of existing R22 / R407c pipework, whilst also allowing the upgrade to some of the most efficient systems available in the market. Replace Multi will clean the existing pipework during commissioning, removing any deposits and R22 mineral oil that would have ordinarily meant that new pipework would have been called for. The implications of this are significant savings on cost and time, whilst also minimising any potential disruption. I I I I I I I I
tried and tested technology that has been employed for over 5 years efficient use of existing resources - refrigerant piping, control and power wiring and less waste materials increased energy efficiency - up to 105% (size 200) more efficient than an old mitsubishi electric r22 system reduced installation costs of up to 55% reduced co2 emissions and running cost savings of up to 45% reduced installation time with minimised disruption ability to replace many non mitsubishi electric systems high Performance heating mode for low ambient conditions
side view
>
Front view
>
city multi Range
r2 series replace multi (8-12hp)
Technical Information model reFerence
PURY-RP200YJM-B
PURY-RP250YJM-B
PURY-RP300YJM-B
heating (nominal)
25.0
31.5
37.5
cooling (nominal)
22.4
28.0
33.5
high Performance heating (uK)
24.0
30.2
36.0
coP Priority heating (uK)
21.8
27.4
32.6
cooling (uK)
21.1
26.3
31.5
Power inPut (kw) heating (nominal)
5.50
7.22
8.70
cooling (nominal)
4.95
6.82
8.35
high Performance heating (uK)
7.26
9.53
11.48
coP Priority heating (uK)
5.34
7.00
8.44
cooling (uK)
3.61
4.98
6.10
4.54 / 4.52
4.36 / 4.10
4.31 / 4.01
caPacity (kw)
coP / eer (nominal) max no. oF connectable indoor units
20
25
30
airFlow (m3/min)
225
225
225
high
noise (dba)
56
57
59
weight (kg)
275
290
290 1220
dimensions (mm) (1650mm without legs)
width
1220
1220
depth
760
760
760
height
1710
1710
1710
electrical suPPly
380-415v, 50hz
380-415v, 50hz
380-415v, 50hz
Phase
3
3
3
starting current (a)
8
8
8
heating
8.9
11.9
14.6
cooling
8.0
11.2
13.6
20
20
25
4 + earth
4 + earth
4 + earth
running current (a)
Fuse rating (mcb sizes bs en 60947-2) - (a) mains cable no. cores
r2 series replace multi (8-12hp)
R2 SERIES REPLACE MULTI OUTDOOR UNITS 8-12hp
R2 Series Replace Multi Piping Restrictions total PiPing length
220m max
height between ou and iu (ou above iu)
50m max
Furthest PiPing length
100m max
height between ou and iu (ou below iu)
40m max
length between ou and bc
70m max
height between iu and bc
15m max
length between Furthest iu and bc
30m max
height between iu and iu
15m max
height between bc (main or sub) and sub bc
15m max
Page 198
Page 199
Dimensions
Water Cooled Condensing Unit Simultaneous Heating and Cooling with Double Heat Recovery
PQRY-P200, 250, 300YHM-A upper view
The WR2 system has double heat recovery potential, making this system very economical. Not only does it produce heat recovery from indoor units on the same refrigerant circuit, it also produces heat recovery via the water circuit between heat source units. Like the YHM-A air source versions, the water cooled units now benefit from a modular design approach. A twinning kit is required for double combinations. I
all the benefits of the r2 series with water cooled condensing units, using a single inverter compressor
I
40% height reduction compared to previous ygm-a models
I
high coPs possible thanks to increased efficiency and careful control of the system, allowing the largest operational water circuit temperature band ever
I
unique 2-pipe refrigerant circuit allows simultaneous heating and cooling plus heat recovery between up to 50 indoor units as with the r2 system
I
total building heat recovery made possible by exchanging energy in both refrigerant and water circuits
I
combining wr2 with waste heat energy provides unique application solutions
I
improved pipe run of 165m with a total system pipe length of up to 750m
I
high sensible cooling Function - by raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants
I
able to operate with closed loop ground source water temperatures, bore hole and slinky applications are now possible
I
easy maintenance - front panel access to all Pcbâ&#x20AC;&#x2122;s
I
condensing units must be situated indoors
Front view
>
>
right side view
>
city multi Range
wr2 series (8-24hp)
Technical Information WR2 SERIES HEAT SOURCE UNITS - 8-24hp model reFerence
Power inPut (kw)
PQRY-P200YHM-A PQRY-P250YHM-A PQRY-P300YHM-A PQRY-P400YSHM-A PQRY-P450YSHM-A PQRY-P500YSHM-A PQRY-P550YSHM-A PQRY-P600YSHM-A heating (nominal)
25.0
31.5
37.5
50.0
56.0
63.0
69.0
cooling (nominal)
22.4
28.0
33.5
45.0
50.0
56.0
63.0
69.0
heating (nominal)
4.12
5.80
8.15
8.65
10.42
12.06
14.65
17.12
cooling (nominal) coP / eer (nominal)
76.5
3.96
5.51
7.44
8.32
9.94
11.57
13.60
15.62
6.06 / 5.65
5.43 / 5.08
4.60 / 4.50
5.78 / 5.40
5.37 / 5.03
5.22 / 4.84
4.70 / 4.63
4.46 / 4.41 50
max no. oF connectable indoor units
20
25
30
40
45
50
50
noise (dba)
47
49
50
50
51
52
52.5
53
weight (kg)
181
181
181
181 + 181
181 + 181
181 + 181
181 + 181
181 + 181
width
880
880
880
880 + 880
880 + 880
880 + 880
880 + 880
880 + 880
depth
550
550
550
550
550
550
550
550
height
1160
1160
1160
1160
1160
1160
1160
1160
dimensions (mm)
(1100 without legs) electrical suPPly
380-415v, 50hz 380-415v, 50hz 380-415v, 50hz 380-415v, 50hz
380-415v, 50hz
3
3
3
3
3
3
3
3
starting current (a)
8
8
8
8/8
8/8
8/8
8/8
8/8
heating
6.3
8.9
12.5
13.3
16.1
18.6
22.6
26.4
cooling
6.1
8.5
11.5
12.8
15.3
17.8
21.0
24.1
20
20
20
20 / 20
20 / 20
20 / 20
20 / 20
20 / 20
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
Fuse rating (bs88) - hrc (a) mains cable no. cores
left side view
>
Front view
>
380-415v, 50hz 380-415v, 50hz 380-415v, 50hz
Phase
running current (a)
PQRY-P400, 450, 500, 550, 600YSHM-A
wr2 series (8-24hp)
caPacity (kw)
PQRY-P200-600Y(S)HM-A Piping restrictions total PiPing length Furthest PiPing length between outdoor and bc controller (master) - length
550m max*3 (300m) for sizes 200-300 / 750m max*3 (500m) for sizes 400-600 165m max 110m max*4
between indoor and bc controller (master/slave) - length
60m max*5 (40m)
between indoor and outdoor - height
50m max (40m*1)
between indoor and indoor - height
15m max (10m*2)
between indoor and bc controller (master/slave) - height
15m max (10m*2)
between bc controller (master) and bc controller (slave) - height
15m max (10m)*6
*1 When O/U is below indoor *2 In case of P200, P250 indoor unit *3 Distance between outdoor unit and BC Controller is 10m or less *4 Total piping length is 300m or less (500m for sizes 400-600) *5 Height difference between the Master BC Controller and furthest indoor unit is zero and no size 200 or 250 indoor unit is used *6 When using 2 sub BC Controllers, the height between them should be considered
Page 200
Page 201
Dimensions
Heat Pump Close Control System
PFD-P250VM-E
Mitsubishi Electric’s new Close Control System is specifically designed for computer rooms, laboratories etc, where a need for high sensible cooling and close control of temperature and humidity is required. Because of the need for close control 24 hours a day, 365 days a year, a newly developed inverter driven compressor has been incorporated into the outdoor unit, maximising the energy efficiency of the PFD series. It is also able to be connected to a computer network using our AG150 controller, in order to monitor and provide remote email alarms.
upper view
Front view high sensible cooling
I
newly developed inverter driven compressor
I
energy efficient with high coP’s
I
close control of temperature, ±1ºc
I
easy to install - no service space needed at the rear of the unit
I
optional third party humidifier available
I
Quick recovery following power failure
I
return or discharge air temperature control
I
back-up & rotate function available
I
connectable to Puhy-P250yJm-a from april 2011
Technical Information PFD-P-VM-E - INDOOR UNITS
PUHY-P-YJM-A - OUTDOOR UNITS
PQHY-P-YHM-A - CONDENSING UNITS
PFD-P250VM-E
PFD-P500VM-E
PUHY-P250YJM-A
PUHY-P250YJM-A x2
PQHY-P250YHM-A PQHY-P250YHM-A x2
heating (nominal)
31.5
63.0
31.5
63.0
31.5
63.0
cooling (nominal)
28.0
56.0
28.0
56.0
28.0
56.0
heating (uK)
29.1
55.4
28.7
54.8
n/a
n/a
cooling (uK)
26.6
51.5
26.6
51.5
n/a
n/a
0.93
0.93
n/a
n/a
n/a
n/a
2.5
5.0
refer to databook
refer to databook
5.51
5.51 / 5.51
model reFerence caPacity (kw)
shF Power inPut (kw)
heating (nominal) cooling (nominal)
2.5
5.0
refer to databook
refer to databook
5.45
5.45 / 5.45
heating (uK)
n/a
n/a
refer to databook
refer to databook
n/a
n/a
cooling (uK)
n/a
n/a
refer to databook
refer to databook
n/a
n/a
160
320
170
170 / 170
n/a
n/a
airFlow (m3/min) external static Pressure (Pa) PiPe siZe mm(in)
120
120
n/a
n/a
n/a
n/a
gas
22.2 (7/8”)
22.2 (7/8”)
22.2 (7/8”)
22.2 (7/8”)
22.2 (7/8”)
22.2 (7/8”)
liquid
9.52 (3/8”)
9.52 (3/8”)
9.52 (3/8”)
9.52 (3/8”)
9.52 (3/8”)
9.52 (3/8”)
noise (dba)
59
63
58
58 / 58
49
49 / 49
weight (kg)
380
520
200
200 + 200
195
195 + 195 880 + 880
dimensions (mm)
width
1380
1980
920
920 + 920
880
depth
780
780
760
760
550
550
height
1950
1950
1710
1710
1160
1160 380-415v, 50hz
electrical suPPly
380-415v, 50hz
380-415v, 50hz
380-415v, 50hz
380-415v, 50hz
380-415v, 50hz
Phase
3
3
3
3
3
3
starting current (a)
47
68
8
8/8
8
8/8
heating
4.9
8.7
refer to databook
refer to databook
8.5
8.5 / 8.5
cooling
4.9
8.7
refer to databook
refer to databook
8.4
8.4 / 8.4
16
20
20
20 / 20
20
20 / 20
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
running current (a)
Fuse rating (bs88) - hrc (a) mains cable no. cores
>
side view
>
PFD-P500VM-E upper view
Front view
>
>
side view
>
PFd-P-vm-e (10/20hp)
I
>
PFD-P-VM-E Piping restrictions total PiPing length between indoor and outdoor units - height
Page 202
city multi Range
PFd-P-vm-e (10/20hp)
165m max 50m max (40m max if outdoor installed below)
Page 203
Dimensions
2, 3 and 4-Way Blow Ceiling Cassette Indoor Unit
PLFY-P32, 40, 50, 63, 80, 100, 125VBM-E
Power cassettes offer 72 different airflow patterns, with the ability to handle a multitude of ceiling applications up to 4.2 metres in height. The easy to install, slim unit is ideal for maintaining constant temperatures, thanks to adjustable vanes that allow users to precisely direct air where it’s needed.
upper view
>
lower view
>
The Mitsubishi Electric airflow control mechanism has been improved and uses wider vanes so that the unit reduces drafts and smudging, whilst a high performance drain pump on the drain lift mechanism allows drain water to be lifted up to 850mm from the ceiling surface. I
handy corner pocket design simplifies maintenance
I
airflow controllable for ceiling heights up to 4.2m, with automatic adjustment of fan speed
I
reduced draft air distribution, with independent vane control
I
drain pump as standard, 850mm from drain pan
I
Filter lowering operation down to 4m (optional PlP-6baJ grille required)
I
optional ‘i see sensor’ for energy saving and smooth temperature control throughout the room
I
For further information on the features of this cassette, please see page 72
city multi Range
PlFy-P-vbm-e
Technical Information PLFY-P-VBM-E - INDOOR UNITS PLFY-P32VBM-E
PLFY-P40VBM-E
PLFY-P50VBM-E
PLFY-P63VBM-E
PLFY-P80VBM-E
PLFY-P100VBM-E
PLFY-P125VBM-E
heating (nominal)
4.0
5.0
6.3
8.0
10.0
12.5
16.0
cooling (nominal)
3.6
4.5
5.6
7.1
9.0
11.2
14.0
hP heating (uK)
4.0
5.0
6.3
8.0
10.0
12.5
16.0
coP P heating (uK)
3.7
4.7
5.9
7.5
9.4
11.7
15.0
cooling (uK)
3.4
4.3
5.3
6.7
8.5
10.6
13.3
high sensible
cooling (uK)
2.6
3.3
4.1
5.2
6.5
8.1
10.2
shF
(uK)
0.82
0.79
0.75
0.73
0.72
0.72
0.70
high sensible
(uK)
0.96
0.91
0.83
0.79
0.78
0.79
0.75
Power inPut (kw)
heating (nominal)
0.02
0.03
0.03
0.04
0.06
0.14
0.15
cooling (nominal)
0.03
0.04
0.04
0.05
0.07
0.15
0.16
caPacity (kw)
airFlow (m3/min)
lo-mi1-mi2-hi
11-12-13-14
12-13-14-16
12-13-14-16
14-15-16-18
16-18-20-22
21-24-27-29
22-25-28-30
noise (dba)
lo-mi1-mi2-hi
27-28-29-31
27-28-30-31
27-28-30-31
28-29-30-32
30-32-35-37
34-37-39-41
35-38-41-43
weight (kg)
(grille)
22(6)
22(6)
22(6)
23(6)
23(6)
27(6)
27(6)
dimensions (mm)
width (grille)
840(950)
840(950)
840(950)
840(950)
840(950)
840(950)
840(950)
depth (grille)
840(950)
840(950)
840(950)
840(950)
840(950)
840(950)
840(950)
height (grille)
258(35)
258(35)
258(35)
258(35)
258(35)
298(35)
298(35)
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
single
single
single
single
single
single
single
running current (a) heating
0.14
0.22
0.22
0.29
0.43
0.94
1.00
cooling
0.22
0.29
0.29
0.36
0.51
1.00
1.07
Fuse rating (bs88) - hrc (a)
6
6
6
6
6
6
6
mains cable no. cores
3
3
3
3
3
3
3
PlP-6ba
PlP-6ba
PlP-6ba
PlP-6ba
PlP-6ba
PlP-6ba
PlP-6ba
electrical suPPly Phase
grille model reFerence
Page 204
side view
>
MODELS
A
B
PlFy-P32-80vbm-e
241
258
PlFy-P100-125vbm-e
281
298
PlFy-P-vbm-e
model reFerence
Page 205
Dimensions
600x600 4-Way Blow Ceiling Cassette Indoor Unit
PLFY-P20, 25, 32, 40VCM-E2
The compact size of this unit is ideal for 600x600mm ceilings and with a depth of 208mm, this lightweight unit makes installation a breeze. This unit also comes complete with a long life filter that will last for approximately 2,500 hours. I
compact size for handy installation and easy maintenance
I
only 208mm high
I
Fresh air duct facility
lower view
Technical Information
side view
>
city multi Range
PlFy-P-vcm-e2
>
model reFerence
PLFY-P20VCM-E2
PLFY-P25VCM-E2
PLFY-P32VCM-E2
PLFY-P40VCM-E2
heating (nominal)
2.5
3.2
4.0
5.0
cooling (nominal)
2.2
2.8
3.6
4.5
hP heating (uK)
2.5
3.2
4.0
5.0
coP P heating (uK)
2.3
3.0
3.7
4.7
cooling (uK)
2.1
2.7
3.4
4.3
high sensible
cooling (uK)
1.6
2.0
2.6
3.3
shF
(uK)
0.86
0.78
0.76
0.70
high sensible
(uK)
1.00
0.95
0.85
0.76
Power inPut (kw)
heating (nominal)
0.05
0.05
0.06
0.06
cooling (nominal)
0.05
0.05
0.06
0.06
lo-mi-hi
8-9-10
8-9-10
8-9-11
8-9-11
noise (dba)
lo-mi-hi
28-31-35
28-31-37
29-33-38
30-34-39
weight (kg)
(grille)
15.5(3)
15.5(3)
17(3)
17(3)
dimensions (mm)
width (grille)
570(650)
570(650)
570(650)
570(650)
depth (grille)
570(650)
570(650)
570(650)
570(650)
height (grille)
235(20)
235(20)
235(20)
235(20)
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
caPacity (kw)
airFlow (m3/min)
electrical suPPly
single
single
single
single
heating
0.23
0.23
0.28
0.28
cooling
0.23
0.23
0.28
0.28
Fuse rating (bs88) - hrc (a)
6
6
6
6
mains cable no. cores
3
3
3
3
slP-2aaw
slP-2aaw
slP-2aaw
slP-2aaw
Phase running current (a)
grille model reFerence
Page 206
PlFy-P-vcm-e2
PLFY-P-VCM-E2 - INDOOR UNITS
Page 207
Dimensions
PLFY-P20, 25, 32, 40, 50, 63, 80, 100VLMD-E
2-Way Blow Ceiling Cassette Indoor Unit
Front view
The PLFY-P-VLMD-E cassette unit fits into the space in a suspended ceiling to provide heating or cooling. This new unit has been redesigned with lower unit height and lower noise levels. I
light unit for ease of installation
I
terminal block on outside of unit for easy wiring
I
drain lift-pump mechanism as standard
I
newly designed pure white decoration panel with air flow switching and swing functions as standard
>
lower view
upper view
>
>
city multi Range
PlFy-P-vlmd-e
Technical Information PLFY-P-VLMD-E - INDOOR UNITS model reFerence
PLFYP20VLMD-E
PLFYP25VLMD-E
PLFYP32VLMD-E
PLFYP40VLMD-E
PLFYP50VLMD-E
PLFYP63VLMD-E
heating (nominal)
2.5
3.2
4.0
5.0
6.3
8.0
10.0
12.5
16.0
cooling (nominal)
2.2
2.8
3.6
4.5
5.6
7.1
9.0
11.2
14.0
hP heating (uK)
2.5
3.2
4.0
5.0
6.3
8.0
10.0
12.5
16.0
coP P heating (uK)
2.3
3.0
3.7
4.7
5.9
7.5
9.4
11.7
15.0
cooling (uK)
2.1
2.7
3.4
4.3
5.3
6.7
8.5
10.6
13.3
high sensible
cooling (uK)
1.6
2.0
2.6
3.3
4.1
5.2
6.5
8.1
10.2
shF
(uK)
0.90
0.78
0.74
0.70
0.72
0.70
0.73
0.73
0.73
high sensible
(uK)
1.00
0.90
0.85
0.76
0.78
0.75
0.82
0.79
0.80
Power inPut (kw) heating (nominal)
0.065
0.065
0.065
0.074
0.075
0.094
0.140
0.150
0.27
cooling (nominal)
0.072
0.072
0.072
0.081
0.082
0.101
0.147
0.157
0.28
caPacity (kw)
side view
PLFYPLFYPLFYP80VLMD-E P100VLMD-E P125VLMD-E
>
CMP-40VLW-C
CMP-63VLW-C CMP-100VLW-C
lo-mi1-mi2-hi
6.5-8.0-9.5
6.5-8.0-9.5
6.5-8.0-9.5
7.0-8.5-10.5
9.0-11.0-12.5
10.0-13.0-15.5
15.5-18.5-22.0
17.5-21.0-25.0
24-27-30-33
noise (dba)
lo-mi1-mi2-hi
27-30-33
27-30-33
27-30-33
29-33-36
31-34-37
32-37-39
33-36-39
36-39-42
40-42-44-46
weight (kg)
(grille)
23(6.5)
23(6.5)
24(6.5)
24(6.5)
27(7.5)
28(7.5)
44(12.5)
47(12.5)
56(13)
dimensions (mm)
width (grille)
776(1080)
776(1080)
776(1080)
776(1080)
946(1250)
946(1250)
1446(1750)
1446(1750)
1708(2010)
depth (grille)
634(710)
634(710)
634(710)
634(710)
634(710)
634(710)
634(710)
634(710)
606(710)
height (grille)*1
290(20)
290(20)
290(20)
290(20)
290(20)
290(20)
290(20)
290(20)
290(20)
220-240v,
220-240v,
220-240v,
220-240v,
220-240v,
220-240v,
220-240v,
220-240v,
220-240v,
50hz
50hz
50hz
50hz
50hz
50hz
50hz
50hz
50hz
Phase
single
single
single
single
single
single
single
single
single
running current (a) heating
0.30
0.30
0.30
0.34
0.35
0.43
0.66
0.69
1.33
cooling
0.36
0.36
0.36
0.40
0.41
0.49
0.72
0.75
1.35
Fuse rating (bs88) - hrc (a)
6
6
6
6
6
6
6
6
6
mains cable no. cores
3
3
3
3
3
3
3
3
3
cmP40vlw-c
cmP40vlw-c
cmP40vlw-c
cmP40vlw-c
cmP63vlw-c
cmP63vlw-c
cmP100vlw-c
cmP100vlw-c
cmP125vlw-c
electrical suPPly
grille model reFerence
side view
>
rear view
>
upper view
>
lower view
>
PlFy-P-vlmd-e
airFlow (m3/min)
PLFY-P125VLMD-E
*1 Void space required is 350mm or more
Page 208
Page 209
Dimensions
1-Way Blow Ceiling Cassette Indoor Unit
PMFY-P20, 25, 32, 40VBM-E
Utilising a compact and lightweight body, the unit is perfect for applications where ceiling space is limited. A total body weight of 14kg makes it one of the lightest available, latest fan technology also makes it one of the quietest. I
compact size for handy installation and easy maintenance
I
newly developed airflow control technology reduces noise levels to only 27dba
I
drain lift pump mechanism allows the drain to be positioned anywhere up to 600mm from the ceilingâ&#x20AC;&#x2122;s surface
I
only 230mm high
I
Fresh air duct facility
I
Pure white grille
upper view
>
lower view
>
city multi Range
PmFy-P-vbm-e
Technical Information PMFY-P-VBM-E - INDOOR UNITS caPacity (kw)
PMFY-P20VBM-E
PMFY-P25VBM-E
PMFY-P32VBM-E
PMFY-P40VBM-E
heating (nominal)
2.5
3.2
4.0
5.0
cooling (nominal)
2.2
2.8
3.6
4.5
hP heating (uK)
2.5
3.2
4.0
5.0
coP P heating (uK)
2.3
3.0
3.7
4.7 4.3
cooling (uK)
2.1
2.7
3.4
high sensible
cooling (uK)
1.6
2.0
2.6
3.3
shF
(uK)
0.86
0.81
0.76
0.72
high sensible
(uK)
1.00
0.95
0.85
0.82
Power inPut (kw)
heating (nominal)
0.042
0.044
0.044
0.054
cooling (nominal)
0.042
0.044
0.044
0.054
lo-mi1-mi2-hi
6.5-7.2-8.0-8.7
7.3-8.0-8.6-9.3
7.3-8.0-8.6-9.3
7.7-8.7-9.7-10.7
noise (dba)
lo-mi1-mi2-hi
27-30-33-35
32-34-36-37
32-34-36-37
33-35-37-39
weight (kg)
(grille)
14(3)
14(3)
14(3)
14(3)
dimensions (mm)
width (grille)
812(1000)
812(1000)
812(1000)
812(1000)
depth (grille)
395(470)
395(470)
395(470)
395(470)
height (grille)
230(30)
230(30)
230(30)
230(30)
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
airFlow (m3/min)
electrical suPPly Phase
single
single
single
single
heating
0.20
0.21
0.21
0.26
cooling
0.20
0.21
0.21
0.26
Fuse rating (bs88) - hrc (a)
6
6
6
6
mains cable no. cores
3
3
3
3
PmP-40bmw
PmP-40bmw
PmP-40bmw
PmP-40bmw
running current (a)
grille model reFerence
Page 210
side view
>
Front view
>
PmFy-P-vbm-e
model reFerence
Page 211
Ultra Thin Ceiling Concealed Ducted Indoor Unit
PEFY-P15, 20, 25, 32, 40, 50, 63 VMS1-E
The ultra thin ceiling concealed ducted indoor unit offers increased flexibility and is particularly suitable for places where low noise operation is desired from a slimline body. I
ultra thin body - height of only 200mm & width of only 790mm (P15-32)
I
extremely quiet operation - as low as 22dba
I
cooling operation set temperature can be set down to 14째c db
I
static pressure of 5-50Pa
I
now available in a size 15, ideal for hotel rooms
upper view
side view
>
city multi Range
PeFy-P-vms1-e
Dimensions
>
Technical Information PEFY-P-VMS1-E - INDOOR UNITS PEFY-P25VMS1-E
PEFY-P32VMS1-E
PEFY-P40VMS1-E
PEFY-P50VMS1-E
PEFY-P63VMS1-E
heating (nominal)
1.9
2.5
3.2
4.0
5.0
6.3
8.0
cooling (nominal)
1.7
2.2
2.8
3.6
4.5
5.6
7.1
hP heating (uK)
1.9
2.5
3.2
4.0
5.0
6.3
8.0
coP P heating (uK)
1.8
2.3
3.0
3.7
4.7
5.9
7.5
cooling (uK)
1.6
2.1
2.7
3.4
4.3
5.3
6.7
high sensible
cooling (uK)
1.2
1.6
2.0
2.6
3.3
4.1
5.2
shF
(uK)
0.94
0.86
0.78
0.76
0.72
0.72
0.73
high sensible
(uK)
1.00
1.00
0.90
0.85
0.82
0.78
0.79
Power inPut (kw)
heating (nominal)
0.03
0.03
0.04
0.05
0.05
0.07
0.07
cooling (nominal)
0.05
0.05
0.06
0.07
0.07
0.09
0.09
5.0-6.0-7.0
5.5-6.5-8.0
5.5-7.0-9.0
6.0-8.0-10.0
8.0-9.5-11.0
9.5-11.0-13.0
12.0-14.0-16.5
5-15-35-50
5-15-35-50
5-15-35-50
5-15-35-50
5-15-35-50
5-15-35-50
5-15-35-50
22-24-28
22-25-29
24-26-30
24-27-32
28-30-33
30-32-35
30-33-36
19
19
19
20
24
24
28
width
790
790
790
790
990
990
1190
depth
700
700
700
700
700
700
700
height
200
200
200
200
200
200
200
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
single
single
single
single
single
single
single
running current (a) heating
0.31
0.36
0.39
0.39
0.45
0.56
0.61
cooling
0.42
0.47
0.50
0.50
0.56
0.67
0.72
Fuse rating (bs88) - hrc (a)
6
6
6
6
6
6
6
mains cable no. cores
3
3
3
3
3
3
3
caPacity (kw)
airFlow (m3/min)
PEFY-P15VMS1-E PEFY-P20VMS1-E
lo-mi-hi
external static Pressure (Pa) lo-mi1-mi2-hi noise (dba) (15Pa)
lo-mi-hi
weight (kg) dimensions (mm)
electrical suPPly Phase
Page 212
Front view
>
model
a
b
c
d
700 752 798 660 PeFy-P40-50vms1-e 900 952 998 860 PeFy-P63vms1-e 1100 1152 1198 1060 PeFy-P15-32vms1-e
e
F
7 9 11
600 800 1000
PeFy-P-vms1-e
model reFerence
Page 213
Dimensions
Ceiling Concealed Ducted Indoor Unit
PEFY-P20, 25, 32, 40, 50, 63, 80, 100, 125VMA-E
The PEFY-P-VMA-E ducted indoor unit is concealed within the ceiling space to allow unobtrusive air conditioning. Flexibility of duct layout allows air flow patterns to be arranged to suit any application.
Front view
I
reduced height - now only 250mm
I
wider range of external static pressure settings across entire range
I
reduced noise levels thanks to the use of a newly designed centrifugal fan - as low as 23dba
I
cooling operation set temperature can be set down to 14ยบc db
I
drain pump included as standard
>
upper view
>
city multi Range
PeFy-P-vma-e
Technical Information PEFY-P-VMA-E - INDOOR UNITS model reFerence
PEFYP20VMA-E
PEFYP25VMA-E
PEFYP32VMA-E
PEFYP40VMA-E
PEFYP50VMA-E
PEFYP63VMA-E
PEFYP80VMA-E
PEFYP100VMA-E
PEFYP125VMA-E
heating (nominal)
2.5
3.2
4.0
5.0
6.3
8.0
10.0
12.5
16.0
cooling (nominal)
2.2
2.8
3.6
4.5
5.6
7.1
9.0
11.2
14.0
hP heating (uK)
2.5
3.2
4.0
5.0
6.3
8.0
10.0
12.5
16.0
coP P heating (uK)
2.3
3.0
3.7
4.7
5.9
7.5
9.4
11.7
15.0
cooling (uK)
2.1
2.7
3.4
4.3
5.3
6.7
8.5
10.6
13.3
high sensible
cooling (uK)
1.6
2.0
2.6
3.3
4.1
5.2
6.5
8.1
10.2
shF
(uK)
0.90
0.78
0.74
0.79
0.79
0.78
0.72
0.79
0.77
high sensible
(uK)
1.00
0.90
0.85
0.91
0.88
0.87
0.78
0.89
0.86
Power inPut (kw) heating (nominal)
0.04
0.04
0.05
0.07
0.09
0.10
0.12
0.22
0.32
cooling (nominal)
0.06
0.06
0.07
0.09
0.11
0.12
0.14
0.24
0.34
6.0-7.5-8.5
6.0-7.5-8.5
7.5-9.0-10.5
10-12-14
12.0-14.5-17.0
13.5-16.0-19.0
14.5-18.0-21.0
23-28-33
28-34-40
caPacity (kw)
airFlow (m3/min)
lo-mi-hi
rear view
>
side view
>
noise (dba) (50Pa)
lo-mi-hi
23-25-26
23-25-26
23-26-29
23-27-30
25-29-32
25-29-33
26-29-34
28-33-37
32-36-40
23
23
23
26
26
32
32
42
42
width
700
700
700
900
900
1100
1100
1400
1400
depth
732
732
732
732
732
732
732
732
732
height
250
250
250
250
250
250
250
250
250
220-240v,
220-240v,
220-240v,
220-240v,
220-240v,
220-240v,
220-240v,
220-240v,
220-240v,
50hz
50hz
50hz
50hz
50hz
50hz
50hz
50hz
50hz
Phase
single
single
single
single
single
single
single
single
single
model
running current (a) heating
0.42
0.42
0.44
0.53
0.63
0.90
1.04
1.36
1.94
PeFy-P20-32vma-e
cooling
0.53
0.53
0.55
0.64
0.74
1.01
1.15
1.47
2.05
Fuse rating (bs88) - hrc (a)
6
6
6
6
6
6
6
6
6
mains cable no. cores
3
3
3
3
3
3
3
3
3
weight (kg) dimensions (mm)
electrical suPPly
Page 214
PeFy-P40-50vma-e PeFy-P63-80vma-e PeFy-P100-125vma-e
a
b
c
d
700 754 800 660 900 954 1000 860 1100 1154 1200 1060 1400 1454 1500 1360
e 7 9 11 14
F
PeFy-P-vma-e
external static Pressure (Pa) - lo-mi1-mi2-mi3-hi 35-50-70-100-150 35-50-70-100-150 35-50-70-100-150 35-50-70-100-150 35-50-70-100-150 35-50-70-100-150 35-50-70-100-150 35-50-70-100-150 35-50-70-100-150
g
600 658 800 858 1000 1058 1300 1358
Page 215
Dimensions
High Static Pressure Ceiling Concealed Ducted Indoor Unit With improved design flexibility as a result of increased external static pressure, the PEFY-P-VMH-E allows authentic duct air conditioning within the strictest aesthetic confines. I
external static pressure of up to 260Pa
I
greater flexibility for duct extension, branching air outlet configuration
I
reduced noise levels thanks to the use of newly designed centrifugal fan
I
duct can be connected to intake side
I
drain lift-pump (option) 550mm of lift
I
cooling operation set temperature can be set down to 14ยบc db
PEFY-P80, 100, 125, 140VMH-E upper view
>
side view
>
side view
>
city multi Range
PeFy-P-vmh-e
Technical Information PEFY-P-VMH-E - INDOOR UNITS PEFY-P80VMH-E
PEFY-P100VMH-E
PEFY-P125VMH-E
PEFY-P140VMH-E
PEFY-P250VMH-E
heating (nominal)
10.0
12.5
16.0
18.0
31.5
cooling (nominal)
9.0
11.2
14.0
16.0
28.0
hP heating (uK)
10.0
12.5
16.0
18.0
31.5
coP P heating (uK)
9.4
11.7
15.0
16.8
29.5
cooling (uK)
8.5
10.6
13.3
15.2
26.5
high sensible
cooling (uK)
6.5
8.1
10.2
11.6
20.3
shF
(uK)
0.74
0.80
0.74
0.74
0.75
high sensible
(uK)
caPacity (kw)
0.83
0.91
0.81
0.82
0.84
Power inPut (kw) heating (nominal)
0.32
0.48
0.48
0.48
1.23
cooling (nominal)
0.32
0.48
0.48
0.48
1.23
18-25
26.5-38.0
26.5-38.0
28-40
72
100-150-200
100-150-200
100-150-200
100-150-200
130-260
38-43
38-44
38-44
38-44
52 (130Pa)
50
70
70
70
100
width
1000
1200
1200
1200
1250
depth
900
900
900
900
1120
height
380
380
380
380
470
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
380-415v, 50hz
single
single
single
single
3
heating
1.47
2.34
2.34
2.35
2.0
cooling
1.47
2.34
2.34
2.35
2.0
Fuse rating (bs88) - hrc (a)
6
6
6
6
6
mains cable no. cores
3
3
3
3
5
airFlow (m3/min)
lo-hi
external static Pressure (Pa) - lo-mi-hi noise (dba) (150Pa) lo-hi weight (kg) dimensions (mm)
electrical suPPly Phase running current (a)
Page 216
PEFY-P250VMH-E upper view
>
PeFy-P-vmh-e
model reFerence
Page 217
Dimensions
Ceiling Suspended Indoor Unit
PCFY-P40VKM-E 51 2
960
2
853
5
indoor unit designed for direct ceiling suspension
I
Flush to wall installation for concealment of service connections
I
drain piping can be connected from left or right
>
254
476
680
57
lower view
> 236
I
side view
10
230
>
84 88
Front view
195
Designed for ultra-quiet operation and easy maintenance, the unit provides comfortable air conditioning for a wide range of applications where floor or wall space cannot be used practically.
city multi Range
PcFy-P-vKm-e
182
85
878
PCFY-P63VKM-E 51 1280
2
2
>
230
236
5
> 680
57
lower view
side view
10
1173
195
>
84 88
Front view
254
476
Technical Information PCFY-P-VKM-E - INDOOR UNITS
4.5
7.1
11.2
14.0
hP heating (uK)
5.0
8.0
12.5
16.0
coP P heating (uK)
4.7
7.5
11.7
15.0
cooling (uK)
4.3
6.7
10.6
13.3
high sensible
cooling (uK)
3.3
5.2
8.1
10.2
shF
(uK)
0.72
0.72
0.70
0.69
high sensible
(uK)
0.79
0.77
0.75
0.75
Power inPut (kw)
heating (nominal)
0.04
0.05
0.09
0.11
cooling (nominal)
0.04
0.05
0.09
0.11
airFlow (m3/min)
lo-mi1-mi2-hi
10-11-12-13
14-15-16-18
21-24-26-28
21-24-27-31
noise (dba)
lo-mi1-mi2-hi
29-32-34-36
31-33-35-37
36-38-41-43
36-39-42-44
24
32
36
38
width
960
1280
1600
1600
depth
680
680
680
680
height
230
230
230
230
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
weight (kg) dimensions (mm)
electrical suPPly Phase
single
single
single
single
heating
0.28
0.33
0.65
0.76
cooling
0.28
0.33
0.65
0.76
Fuse rating (bs88) - hrc (a)
6
6
6
6
mains cable no. cores
3
3
3
3
running current (a)
Page 218
85
PCFY-P100, 125VKM-E Front view
>
51 2
1600 1493
2
10 5
lower view
side view
>
> PcFy-P-vKm-e
cooling (nominal)
182 1198
236
16.0
84 88 195 230
PCFY-P125VKM-E
12.5
57
PCFY-P100VKM-E
8.0
680
PCFY-P63VKM-E
5.0
476
PCFY-P40VKM-E heating (nominal)
caPacity (kw)
254
model reFerence
182
85
1518
Page 219
Dimensions
Wall Mounted Indoor Units
PKFY-P15, 20, 25VBM-E
An elegant design combined with compact dimensions and quiet operation make the PKFY-P an ideal unit choice. Noise levels are significantly reduced thanks to a unique airflow passage design that not only makes the unit one of the quietest in the industry, but also suppresses condensation and prevents mixing with secondary air. I
compact flat panel design - only 815mm wide (vbm-e)
I
Front grille opening for easy cleaning
I
Front power supply for easy wiring after installation
I
5-way piping provides more flexibility in selection of installation sites
Front view
>
right side view
>
right side view
>
city multi Range
PKFy-P-vbm-e/vhm-e/vKm-e
PKFY-P32, 40, 50VHM-E
Front view
Technical Information
>
PKFY-P-VBM-E / VHM-E / VKM-E - INDOOR UNITS model reFerence
PKFY-P15VBM-E PKFY-P20VBM-E PKFY-P25VBM-E PKFY-P32VHM-E PKFY-P40VHM-E PKFY-P50VHM-E PKFY-P63VKM-E 1.9
2.5
3.2
4.0
5.0
6.3
8.0
cooling (nominal)
1.7
2.2
2.8
3.6
4.5
5.6
7.1
hP heating (uK)
1.9
2.5
3.2
4.0
5.0
6.3
8.0
coP P heating (uK)
1.8
2.3
3.0
3.7
4.7
5.9
7.5
cooling (uK)
1.6
2.1
2.7
3.4
4.3
5.3
6.7
high sensible
cooling (uK)
1.2
1.6
2.0
2.6
3.3
4.1
5.2
shF
(uK)
0.75
0.71
0.70
0.76
0.74
0.72
0.78
high sensible
(uK)
0.83
0.75
0.80
0.85
0.82
0.78
0.85
Power inPut (kw)
heating (nominal)
0.04
0.04
0.04
0.03
0.03
0.03
0.04
cooling (nominal)
0.04
0.04
0.04
0.04
0.04
0.04
0.05
55
688
5
249
155 898
lo-mi1-mi2-hi
4.9-5.0-5.2-5.3
4.9-5.2-5.6-5.9
4.9-5.2-5.6-5.9
9-10-11
9-10.5-11.5
9-10.5-12
16-20
noise (dba)
lo-mi1-mi2-hi
29-31-32-33
29-31-34-36
29-31-34-36
34-37-41
34-38-41
34-39-43
39-45
10
10
10
13
13
13
21
width
815
815
815
898
898
898
1170
depth
225
225
225
249
249
249
295
height
295
295
295
295
295
295
365
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
single
single
single
single
single
single
single
0.20
0.20
0.20
0.30
0.30
0.30
0.30
weight (kg) dimensions (mm)
electrical suPPly Phase running current (a)
heating cooling
>
right side view
>
74
(855)
241
295
5
1170 0.20
0.20
0.20
0.40
0.40
0.40
0.37
Fuse rating (bs88) - hrc (a)
6
6
6
6
6
6
6
mains cable no. cores
3
3
3
3
3
3
3
Page 220
Front view
365
airFlow (m3/min)
PKFY-P63VKM-E
Page 221
PKFy-P-vbm-e / PKFy-P-vhm-e / PKFy-P-vKm-e
heating (nominal)
295
caPacity (kw)
Floor Standing Concealed Indoor Unit
PFFY-P20, 25, 32, 40, 50, 63VLRM-E
A compact concealed unit providing simple, effective air conditioning in perimeter zones. The unit is easy to install and at only 220mm deep offers an unobtrusive method of delivering highly efficient air-conditioning performance. I
concealed unit for hidden installation
I
ideal for perimeter refurbishments
I
cooling operation set temperature can be set down to 14ยบc db
upper view
Front view
>
>
city multi Range
PFFy-P-vlrm-e
Dimensions
Technical Information PFFY-P-VLRM-E - INDOOR UNITS PFFY-P50VLRM-E PFFY-P63VLRM-E
PFFY-P20VLRM-E
PFFY-P25VLRM-E
PFFY-P32VLRM-E
PFFY-P40VLRM-E
heating (nominal)
2.5
3.2
4.0
5.0
6.3
8.0
cooling (nominal)
2.2
2.8
3.6
4.5
5.6
7.1
hP heating (uK)
2.5
3.2
4.0
5.0
6.3
8.0
coP P heating (uK)
2.3
3.0
3.7
4.7
5.9
7.5
cooling (uK)
2.1
2.7
3.4
4.3
5.3
6.7
high sensible
cooling (uK)
1.6
2.0
2.6
3.3
4.1
5.2
shF
(uK)
0.81
0.70
0.74
0.72
0.74
0.73
high sensible
(uK)
0.88
0.80
0.81
0.79
0.80
0.79
Power inPut (kw)
heating (nominal)
0.04
0.04
0.06
0.065
0.085
0.10
cooling (nominal)
0.04
0.04
0.06
0.065
0.085
0.10
caPacity (kw)
airFlow (m3/min)
lo-hi
5.5-6.5
5.5-6.5
7-9
9-11
12-14
12-15.5
noise (dba)
lo-hi
34-40
34-40
35-40
38-43
38-43
40-46
18.5
18.5
20
21
25
27
width
886
886
1006
1006
1246
1246
depth
220
220
220
220
220
220
height
639
639
639
639
639
639
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
single
single
single
single
single
single
heating
0.19
0.19
0.29
0.32
0.40
0.46
cooling
0.19
0.19
0.29
0.32
0.40
0.46
Fuse rating (bs88) - hrc (a)
6
6
6
6
6
6
mains cable no. cores
3
3
3
3
3
3
weight (kg) dimensions (mm)
electrical suPPly Phase running current (a)
Page 222
side view
>
PFFy-P-vlrm-e
model reFerence
Page 223
Dimensions
Floor Standing Concealed Indoor Unit
PFFY-P20, 25, 32, 40, 50, 63VLRMM-E
A compact concealed unit providing simple, effective air conditioning in perimeter zones. The unit is easy to install and at only 220mm deep offers an unobtrusive method of delivering highly efficient air-conditioning performance. I
reduced noise levels compared to the PFFy-P-vlrm-e version
I
cooling operation set temperature can be set down to 14ยบc db
I
static pressure. the new unit has 3 static pressure settings - 20/40/60Pa ideal for ducting in the perimeter zone
I
concealed unit for hidden installation. the unit can be hidden behind a wardrobe in a hotel, then ducted above and below the wardrobe doors. this offers lower noise, less disruption and a low visual impact
upper view
Front view
>
city multi Range
PFFy-P-vlrmm-e
>
Technical Information PFFY-P-VLRMM-E - INDOOR UNITS caPacity (kw)
PFFY-P20VLRMM-E
PFFY-P25VLRMM-E
PFFY-P32VLRMM-E
PFFY-P40VLRMM-E
PFFY-P50VLRMM-E
PFFY-P63VLRMM-E
heating (nominal)
2.5
3.2
4.0
5.0
6.3
8.0
cooling (nominal)
2.2
2.8
3.6
4.5
5.6
7.1
hP heating (uK)
2.5
3.2
4.0
5.0
6.3
8.0
coP P heating (uK)
2.3
3.0
3.7
4.7
5.9
7.5 6.7
cooling (uK)
2.1
2.7
3.4
4.3
5.3
high sensible
cooling (uK)
1.6
2.0
2.6
3.3
4.1
5.2
shF
(uK)
0.81
0.70
0.74
0.72
0.74
0.73
high sensible
(uK)
0.88
0.80
0.81
0.79
0.80
0.79
Power inPut (kw)
heating (nominal)
0.04
0.04
0.04
0.05
0.05
0.07
cooling (nominal)
0.04
0.04
0.04
0.05
0.05
0.07
4.5-5.5-6.5
4.5-5.5-6.5
6.5-7.5-9
8-9.5-11
10-12-14
11-13-15.5
external static Pressure (Pa) lo-mi-hi
20-40-60
20-40-60
20-40-60
20-40-60
20-40-60
20-40-60
noise (dba) (20Pa)
31-36-40
31-36-40
27-32-37
30-36-40
32-37-41
35-40-44
18.5
18.5
20
21
25
27
width
886
886
1006
1006
1246
1246
depth
220
220
220
220
220
220
height
639
639
639
639
639
639
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
Phase
single
single
single
single
single
single
running current (a) heating
0.34
0.34
0.38
0.43
0.48
0.59
cooling
0.34
0.34
0.38
0.43
0.48
0.59
Fuse rating (bs88) - hrc (a)
6
6
6
6
6
6
mains cable no. cores
3
3
3
3
3
3
airFlow (m3/min)
lo-mi-hi
lo-mi-hi
weight (kg) dimensions (mm)
electrical suPPly
Page 224
side view
>
PFFy-P-vlrmm-e
model reFerence
Page 225
Dimensions
Floor Standing Exposed Indoor Unit
PFFY-P20,25,32,40,50,63VLEM-E
A compact cased unit providing simple, effective air conditioning in perimeter zones. The unit is easy to install, and at only 220mm deep offers an unobtrusive method of delivering a highly efficient air-conditioning performance. I
remote controller can be incorporated into the main unit
I
cooling operation set temperature can be set down to 14ยบc db
upper view
Front view
>
>
city multi Range
PFFy-P-vlem-e
Technical Information PFFY-P-VLEM-E - INDOOR UNITS PFFY-P20VLEM-E
PFFY-P25VLEM-E
PFFY-P32VLEM-E
PFFY-P40VLEM-E
heating (nominal)
2.5
3.2
4.0
5.0
6.3
8.0
cooling (nominal)
2.2
2.8
3.6
4.5
5.6
7.1
hP heating (uK)
2.5
3.2
4.0
5.0
6.3
8.0
coP P heating (uK)
2.3
3.0
3.7
4.7
5.9
7.5
cooling (uK)
2.1
2.7
3.4
4.3
5.3
6.7
high sensible
cooling (uK)
1.6
2.0
2.6
3.3
4.1
5.2
shF
(uK)
0.81
0.70
0.74
0.72
0.74
0.73
high sensible
(uK)
0.88
0.80
0.81
0.79
0.80
0.79
Power inPut (kw)
heating (nominal)
0.04
0.04
0.06
0.065
0.085
0.10
cooling (nominal)
0.04
0.04
0.06
0.065
0.085
0.10
caPacity (kw)
PFFY-P50VLEM-E PFFY-P63VLEM-E
airFlow (m3/min)
lo-hi
5.5-6.5
5.5-6.5
7-9
9-11
12-14
12-15.5
noise (dba)
lo-hi
34-40
34-40
35-40
38-43
38-43
40-46
23
23
25
26
30
32
width
1050
1050
1170
1170
1410
1410
depth
220
220
220
220
220
220
height
630
630
630
630
630
630
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
single
single
single
single
single
single
heating
0.19
0.19
0.29
0.32
0.40
0.46
cooling
0.19
0.19
0.29
0.32
0.40
0.46
Fuse rating (bs88) - hrc (a)
6
6
6
6
6
6
mains cable no. cores
3
3
3
3
3
3
weight (kg) dimensions (mm)
electrical suPPly Phase running current (a)
Page 226
side view
>
PFFy-P-vlem-e
model reFerence
Page 227
Dimensions
Floor Standing Exposed Indoor Unit
PFFY-P20,25,32,40VKM-E
The PFFY-P-VKM-E series is extremely versatile and is designed for wall attached installation at floor level. The auto swing vane provides a more natural and comfortable airflow throughout the room and the lightweight, compact design makes installation easy. I
Pure white, slimline design
I
upper and lower vanes for optimum, powerful and efficient air distribution
upper view
>
Front view
>
city multi Range
PFFy-P-vKm-e
Technical Information PFFY-P-VKM-E - INDOOR UNITS PFFY-P20VKM-E
PFFY-P25VKM-E
PFFY-P32VKM-E
PFFY-P40VKM-E
heating (nominal)
2.5
3.2
4.0
5.0
cooling (nominal)
2.2
2.8
3.6
4.5
hP heating (uK)
2.5
3.2
4.0
5.0
coP P heating (uK)
2.3
3.0
3.7
4.7
cooling (uK)
2.1
2.7
3.4
4.3
high sensible
cooling (uK)
1.6
2.0
2.6
3.3
shF
(uK)
0.81
0.74
0.71
0.70
high sensible
(uK)
0.88
0.85
0.77
0.76
Power inPut (kw)
heating (nominal)
0.025
0.025
0.025
0.028
cooling (nominal)
0.025
0.025
0.025
0.028
caPacity (kw)
airFlow (m3/min)
lo-mi1-mi2-hi
5.9-6.8-7.6-8.7
6.1-7.0-8.0-9.1
6.1-7.0-8.0-9.1
8.0-9.0-9.5-10.7
noise (dba)
lo-mi1-mi2-hi
27-31-34-37
28-32-35-38
28-32-35-38
35-38-42-44
15
15
15
15
width
700
700
700
700
depth
200
200
200
200
height
600
600
600
600
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
single
single
single
single
heating
0.20
0.20
0.20
0.24
cooling
0.20
0.20
0.20
0.24
Fuse rating (bs88) - hrc (a)
6
6
6
6
mains cable no. cores
3
3
3
3
weight (kg) dimensions (mm)
electrical suPPly Phase running current (a)
Page 228
side view
>
PFFy-P-vKm-e
model reFerence
Page 229
Dimensions
Lossnay Outdoor Air Processing Indoor Unit
GUF-50/100RD3
The GUF-50RD3 and GUF-100RD3 outdoor air processing units can be used with any of the extensive range of City Multi indoor units to provide ventilation, dust removal, humidification and heat recovery.
side view
I
a combination of a lossnay & city multi indoor in a single unit
I
air temperature in any room can be adjusted to the desired temperature via this unit which is used as an indoor unit of the city multi air conditioning system
I
the ventilating and air conditioning functions are integrated in a single unit, saving space and installation costs
I
heat recovery helps to save energy - a benefit that’s not only good for the environment, but also great for cutting energy costs
I
Free cooling is also available should outdoor conditions be suitable
>
upper view
city multi Range
guF-rd3
>
Technical Information OUTDOOR AIR PROCESSING INDOOR UNITS model reFerence caPacity (kw)
GUF-50RD3
GUF-100RD3
heating (nominal)
6.42 (2.25)
13.00 (4.70)
cooling (nominal)
5.29 (1.66)
10.81 (3.49)
hP heating (uK)
6.42 (2.25)
13.00 (4.70)
coP P heating (uK)
5.93 (2.08)
12.01 (4.34)
cooling (uK)
5.03 (1.58)
10.27 (3.32)
Power inPut (kw) airFlow (m3/h)
lo-hi
external static Pressure (Pa) noise (dba)
0.505
400-500
800-1000
140
140
lo-hi
33.5-34.5
38-39
54
92
width
1016
1231
depth
1288
1580
height
317
398
220-240v, 50hz
220-240v, 50hz
weight (kg) dimensions (mm)
0.265
electrical suPPly Phase
single
single
0.70-1.15
1.73-2.20
Fuse rating (bs88) - hrc (a)
6
6
mains cable no. cores
3
3
running current (a)
attention
lo-hi
Front view
>
1. nominal condition: Cooling/Heating capacity indicates the value of operation under the following air condition and above air volume. Cooling: Indoor 27ºC DB/19.5ºC WB, Outdoor 35ºC DB/24ºC WB. Heating: Indoor 21ºC DB/14.6ºC WB, Outdoor 7ºC DB/6ºC WB. 2. uK condition: Summer: Indoor 21ºC, Outdoor 27ºC Winter: Indoor 21ºC, Outdoor -1ºCWB
guF-rd3
3. The figures in ( ) indicates the heat recovery at Lossnay core. 4. The current, input and efficiency are based on the above air volume. 5. The air nozzle noise (45º angle 1.5m ahead) is about 6dB greater than the indicated value. (High notch). 6. Specifications may be subject to change without notice.
Page 230
Page 231
Dimensions
VRF Heat Pump Boiler
PWFY-P100VM-E-BU upper view
> 205 (Mounting pitch) 300
the mitsubishi electric booster unit (PwFy-P100vm-e-bu) can achieve a flow temperature of 70ºC and is an ideal solution for providing a hot water supply to commercial buildings in an energy efficient manner. Heat pump technology works by extracting heat from the air and upgrading it to heat a building. This process in itself is energy efficient, however we can take this a step further by using heat recovery. Heat recovery technology taps into and utilises otherwise wasted heat energy, extracted from areas of a building that require cooling, providing heating for hot water almost for free. Recovering the heat in this manner maximises the efficiency of the system all year round, therefore increasing energy savings and lowering running costs. Taking full advantage of heat recovery technology, the 12.5kW PWFY booster unit upgrades the heat pump energy to higher temperatures required to achieve 70ºC water temperatures. This is possible using the first ever VRF cascade refrigeration system between R410A and R134a refrigerant. The benefit of having air conditioning as well as a hot water supply from a single system means that the unit is suitable for a variety of applications. Offices, hotels, gyms, restaurants etc are typical examples of buildings that already have an air conditioning system in place. Providing the essential hot water supply to these applications is a simple addition of the booster unit to the existing air conditioning system. It is a perfect solution that allows inconveniences that arise when installing gas boilers such as gas grid connection costs, meter installation and maintenance costs to be eliminated. Further there is a reduction in running costs and carbon emissions due to the high efficiency of these units over gas boilers.
450 500 (Mounting pitch) 525
Front view
I
> Water outlet (RC3/4 screw)
35
Control box
46
Connection pipe of outdoor unit (Gas) ø15.88 <Brazed>
60 480 140
800
91
134
Service panel
can be used in conjunction with cmb-Pw202v-J to allow a 200% heat recovery index uses the Par-w21maa controller
80
100
102 165
191
91
Connection pipe of outdoor unit (Liquid) ø9.52 <Brazed>
35
114
55
Technical Information
Water inlet (R3/4 screw)
54
The Mitsubishi Electric air to water heating units (PWFY-P100/200VM-E-AU) can achieve flow temperatures of 45ºC in heating and 10ºC in cooling, making them perfect for application on underfloor heating/cooling systems. I
side view
>
city multi Range
PwFy-P
Drain (R1 screw)
184
PWFY-P100/200VM-E-AU
PWFY-P caPacity
heating (nominal) cooling (nominal) heating (uK)
Power inPut (kw) comPatible outdoor / condensing units
PWFY-P100VM-E-BU
PWFY-P100VM-E-AU
PWFY-P200VM-E-AU
12.5
12.5
25.0
-
11.2
22.4
12.5
10.4
20.8
2.48
0.015
0.015
Pury / PQry
Puhy / PQhy / Pury / PQry
Puhy / PQhy / Pury / PQry
reFrigerant charge (kg) high temp circuit
1.1 (r134a)
-
-
PiPe siZe (mm) (in)
gas
15.88 (5/8")
15.88 (5/8")
19.05 (3/4")
liquid
9.52 (3/8")
9.52 (3/8")
9.52 (3/8")
water
19.05 (3/4”)
19.05 (3/4”)
19.05 (3/4”)
drain
ø32 (1 1/4”)
ø32 (1 1/4”)
ø32 (1 1/4”)
noise (dba)
44
29
29
weight (kg)
60
35
38
upper view
> 205 (Mounting pitch) 300
model reFerence
450 500 (Mounting pitch) 525
Front view
side view
>
> Water outlet (RC3/4 screw) P200:Use the Expansion joint of accessories
Control box 35
46 60 140
Connection pipe of outdoor unit (Gas) P100:ø15.88 <Brazed> P200:ø19.05 <Brazed>
134
480
800
91
depth
300
300
300
height
785 (800)
785 (800)
785 (800)
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
Phase
single
single
single
running current (a)
10.66
0.063
0.063
Fuse rating (bs88) - hrc (a)
25
6
6
mains cable no. cores
3
3
3
water Flow rate m3/h
0.6-2.15
0.6-2.15
1.2-4.3
91
35
electrical suPPly
55
Connection pipe of outdoor unit (Liquid) ø9.52 <Brazed> Water inlet (R3/4 screw) 114
Drain (R1 screw) 206
PwFy-P
450
54
450
191
450
80
width
102 165
dimensions (mm)
100
Service panel
note: The PWFY-P200VM-E-AU will require 2 expansion joints
Page 232
Page 233
Air Curtain System
Dimensions
AIR CURTAIN vrF Phv1000/1500/2000r dxe
In collaboration with Thermoscreens 速, Mitsubishi Electric have developed a range of air curtains that are able to be connected to our City Multi VRF systems, as opposed to the more traditional direct electric method associated with air curtains. I
reduced co2 emissions
I
reduced running costs
I
inverter technology (does not waste energy)
I
range of different sizes to suit every application
I
allows open door policy in retail outlets whilst being energy efficient
I
clean environment - protection from dust, fumes etc
I
comfortable climate for customers
I
easy to install and maintain
I
heat recovery possible, optimising energy use
side view
>
rear view
>
upper view
>
city multi Range
vrF Phv dxe Heat Pump Air Curtain
Technical Information
AIR CURTAIN vrF Phv1000/1500/2000 dxe
model reFerence dimensions (mm) (wxdxh) suPPly (50hz) heat outPut (kw) loading (amps) velocity (m/s)
VRF PHV1000R DXE HO
VRF PHV1500R DXE LO
VRF PHV1500R DXE HO
VRF PHV2000R DXE LO
VRF PHV2000R DXE HO
1150x436x296
1650x436x296
1650x436x296
2240x436x296
2240x436x296
415v*1
415v*1
415v*1
415v*2
415v*2
9
10.6
15.1
16.4
21.4
7.8*1
12.7*1
12.7*1
15.7*2
15.7*2
9
9
9
9.5
9
1400
2500
2600
3300
3130
weight (kg)
45
66
67
85
88
noise db(a) @ 3m
56
58
58
59
59
3.5
3.5
3.5
3.5
air volume (m3/h)
max. mounting height (m) outdoor unit model
Pumy / Puhy / Pury / PQhy / PQry Pumy / Puhy / Pury / PQhy / PQry Pumy / Puhy / Pury / PQhy / PQry Pumy / Puhy / Pury / PQhy / PQry
side view
>
rear view
>
vrF Phv dxe Heat Pump Air Curtain
VRF PHV DXE - RECESSED
3.5 Puhy / Pury / PQhy / PQry
notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load (1.3 amp load for VRF PHV1000R DXE HO) *2 for units with electric heaters disabled, 240v power supply 2.7 amp load.
upper view
VRF PHV DXE - FREE STANDING model reFerence dimensions (mm) (wxdxh) suPPly (50hz) heat outPut (kw) loading (amps) velocity (m/s)
VRF PHV1000 DXE HO
VRF PHV1500 DXE LO
VRF PHV1500 DXE HO
VRF PHV2000 DXE LO
VRF PHV2000 DXE HO
1196x377x255
1746x377x255
1746x377x255
2296x377x255
2296x377x255
415v*1
415v*1
415v*1
415v*2
415v*2
9
10.6
15.1
16.4
21.4
7.8*1
12.7*1
12.7*1
15.7*2
15.7*2
9
9
9
9.5
9
1400
2500
2600
3300
3130
weight (kg)
39
59
60
78
80
noise db(a) @ 3m
56
58
58
59
59
3.75
3.75
3.75
3.75
air volume (m3/h)
max. mounting height (m) outdoor unit model
Pumy / Puhy / Pury / PQhy / PQry Pumy / Puhy / Pury / PQhy / PQry Pumy / Puhy / Pury / PQhy / PQry Pumy / Puhy / Pury / PQhy / PQry
>
3.75 Puhy / Pury / PQhy / PQry
notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load (1.3 amp load for VRF PHV1000 DXE HO) *2 for units with electric heaters disabled, 240v power supply 2.7 amp load.
Page 234
Page 235
Dimensions
Sensible Cooling, Chilled Water Wall Mounted Indoor Unit In collaboration with Thermoscreens ®, Mitsubishi Electric have developed a sensible cooling wall mounted unit that can be connected to our City Multi VRF systems via the PWFY-P200VM-E-AU heat pump boiler. This unit offers 100% sensible cooling (SHF of 1) for use in server rooms and other sensible cooling applications. shF of 1 and capacity validated by 3rd party assessment (bsria)
I
reduced co2 emissions
I
reduced running costs
I
inverter technology (does not waste energy)
I
easy to install and maintain
I
ideal for small to medium size server rooms / laboratories
I
no 3rd party humidifier is required
I
Par-w21maa controller included
I
ideal for heat recovery applications - use with the water system connection box (wcb) on page 240 to achieve full heat recovery potential
side view
>
rear view
>
C. 150min. for pipes
I
INDOOR UNIT vrF Phv2000 nt
295
255
upper view
upper view
>
city multi Range
vrF Phv nt
>
PwFy-P (not included)
Technical Information VRF PHV NT - indoor units 2296
depth
377
height
255
cooling
12.0
shF electrical suPPly Phase loading (a) velocity (m/s) air volume (m3/h) weight (kg) noise (dba) @ 3m water volume Flow rate (m3/h) hydraulic resistance (kPa @ 3.18 m3/h) hydraulic resistance oF PwFy-P200vm-e-au (kPa @ 3.18 m3/h)
1.0 220-240v, 50hz single 2.7 9 2885 90 59 3.18 36 38*1
water volume oF coil (litres)
5.1
water volume oF heat exchanger in PwFy-P200vm-e-au (litres)
2.09
outdoor unit model
36
caPacity (kw)
VRF PHV2000 NT width
Puhy / Pury / PQhy / PQry
vrF Phv nt Sensible Cooling Chilled Water Unit
dimensions (mm)
168
model reFerence
notes: For use with a Mitsubishi Electric PWFY-P200VM-E-AU water cooling unit as part of a VRF system. Water flow temperature from the PWFY-P is to be set to 10ºC (cannot be set lower) Test conditions: 35ºC DB / 27ºC WB outdoor conditions, 24ºC DB / 40% relative humidity indoor conditions - validated by BSRIA tests. *1 Without strainer.
Page 236
Page 237
Dimensions
At the heart of both the R2 and WR2 Series, the BC controller makes simultaneous heating and cooling possible. It has the inherent ‘intelligence’ to be the system’s decision-maker. I I I I
I I I
CMB-P104, 105, 106V-G1 upper view
transferring energy around the system drawing on energy from the heat source units/outdoor units directing energy as requested by the individual indoor units instructs the heat source unit/outdoor unit on the amount of refrigerant (liquid or gas) that is required to achieve the requested cooling or heating requirements allows unique 2-pipe heat recovery application hic circuit for improved efficiency new brazed connections
>
side view
>
cmb-P104v-g1 cmb-P105v-g1 cmb-P106v-g1
a
b
3 4 5
180 240 300
CMB-P108, 1010, 1013, 1016V-GA1/HA1 Technical Information
upper view
>
side view
city multi Range
bc controllers
>
BC CONTROLLERS model reFerence
CMB-P104V-G1
CMB-P105V-G1
number oF connections
4
5
6
weight (kg)
24
27
28
dimensions (mm)
CMB-P106V-G1
width
648
648
648
depth
432
432
432
height
284
284
284
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
Phase
single
single
single
Power inPut (Kw)
0.085
0.104
0.123
running current (a)
electrical suPPly
0.36
0.44
0.52
Fuse rating (bs88) – hrc (a)
6
6
6
mains cable no. cores
3
3
3
cmb-P108v-ga1 cmb-P1010v-ga1 cmb-P1013v-ga1 cmb-P1016v-ga1/ha1
note: CMB-P-V-G1 units are for use with PURY-(E)P200-350 YJM-A & PQRY-P200-300YHM-A units only.
number oF connections weight (kg)
CMB-P108V-GA1
CMB-P1010V-GA1
CMB-P1013V-GA1
CMB-P1016V-GA1
CMB-P1016V-HA1
8
10
13
16
16
43
48
55
62
69
width
1110
1110
1110
1110
1110
depth
520
520
520
520
520
height
289
289
289
289
289
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
Phase
single
single
single
single
single
Power inPut (Kw)
0.161
0.198
0.255
0.312
0.312
running current (a)
0.68
0.83
1.07
1.30
1.30
Fuse rating (bs88) – hrc (a)
6
6
6
6
6
mains cable no. cores
3
3
3
3
3
dimensions (mm)
electrical suPPly
b
7 9 12 15
420 540 720 900
CMB-P104, 108V-GB1
MASTER BC CONTROLLERS model reFerence
a
upper view
>
side view
>
cmb-P104v-gb1 cmb-P108v-gb1
note: CMB-P-V-GA1 units are for use with PURY-(E)P200-650Y(S)JM-A(1) & PQRY-P200-600Y(S)HM-A units only. CMB-P1016V-HA1 unit is for use with PURY-(E)P700-900YSJM-A units only.
a
b
3 7
180 420
SLAVE BC CONTROLLERS CMB-P104V-GB1
CMB-P108V-GB1
CMB-P1016V-HB1
number oF connections
4
8
16
weight (kg)
22
32
55
width
648
648
1098
depth
432
432
432
dimensions (mm)
height
284
284
284
220-240v, 50hz
220-240v, 50hz
220-240v, 50hz
Phase
single
single
single
Power inPut (Kw)
0.076
0.151
0.301
running current (a)
0.32
0.63
1.26
Fuse rating (bs88) – hrc (a)
6
6
6
mains cable no. cores
3
3
3
electrical suPPly
Page 238
CMB-P1016V-HB1 upper view
>
side view
>
bc controllers
model reFerence
Page 239
Following the success of PWFY, this new low cost branch controller allows simple heat recovery between 2 ports, one being heating only with PWFY, the other being heating or cooling with PWFY or standard indoor units. A key factor
Dimensions
CMB-PW202V-J
with the WCB is the ability to allow 200% connectable index to the system. Typically the outdoor unit of a system is sized to match the internal load. For a communications room there is a continuous cooling load and under normal circumstances all the heat is wasted to the outside.
upper view
>
By utilising a WCB, a system can be sized for the cooling load of a communications room and then use the delivery of cold water from a PWFY to achieve this. The system can then benefit from full heat recovery of up to 200% by connecting a second PWFY in heating mode that can deliver sanitary hot water or hot water for space heating elsewhere in the building. I
total heat recovery, transferring all energy around the system
I
200% connectable heat recovery index for optimum efficiency, flexibility and cost savings (130% when connecting with standard indoor units)
I
energy saving mode available (longer heat up time, but with a 15% coP improvement on standard control)
I
installation cost and time savings
I
connectable to both bu and au PwFy models
city multi Range
water system connection box (wcb)
Technical Information WCB model reFerence
>
Pury-(e)P200-350yJm-a / PQry-P200-300yhm-a
weight (kg)
20
dimensions (mm)
width
648
depth
432
height
284
electrical suPPly
220-240v, 50hz
Phase
single
Power inPut (Kw)
0.024
running current (a)
0.10
Fuse rating (bs88) â&#x20AC;&#x201C; hrc (a)
6
mains cable no. cores
3
example 1:
side view
CMB-PW202V-J
comPatible outdoor / condensing units
200% connection with continual heating only and cooling only Ports PwFy-P200au (heating) to underfloor heating
Front view
> water connection box (wcb)
outdoor heat recovery unit (size 200)
PwFy-P200au (cooling) to third party comms room unit
wcb
example 2:
130% connection with hot water and cooling/heating indoor units note: 100% if only in heating
outdoor heat recovery unit (size 200)
wcb
Page 240
PwFy-P100bu (hot water) to tank
3 x PeFy-P50vma (cooling/heating) restaurant
Page 241
Air Handling Unit Controller outdoor units
Mitsubishi Electric City Multi outdoor units can be used with this interface box, creating and ideal solution when a unique air handling unit is required. The Air Handling Unit Controllers are supplied with LEV expansion device(s). I I I I I
discharge or return air temperature control temperature set point by control 0-10vdc auto mode available for ease of application error input iP2x rated (only for internal use)
Technical Information
4-way blow cassette units
PAC-AH-M-J - AHU CONTROLLER model reFerence air handling unit siZe allowed heat exchanger caPacity (kw) - heating allowed heat exchanger caPacity (kw) - cooling
PAC-AH125M-J
PAC-AH125M-J
PAC-AH140M-J
PAC-AH250M-J
PAC-AH250M-J
PAC-AH500M-J
P100
P125
P140
P200
P250
P400*2
PAC-AH500M-J P500*2
10.0 - 12.5
12.5 - 16.0
16.0 - 18.0
18.0 - 25.0
25.0 - 31.5
40.0 - 50.0
50.0 - 63.0
9.0 - 11.2
11.2 - 14.0
14.0 - 16.0
16.0 - 22.4
22.4 - 28.0
36.0 - 45.0
45.0 - 56.0
1500 - 2850
1900 - 3550
2150 - 4050
3000 - 5700
3750 - 7100
6000 - 11400
7500 - 14200
reFerence air Flow rate (m3/h)*3
2000
2500
3000
4000
5000
8000
10000
standard evaPorator Path number*1
4 - 5
4 - 5
5 - 6
6 - 10
8 - 10
16 - 20
16 - 20
allowed heat exchanger volume (cm3)
dimensions (mm)
width
328
328
328
328
328
328
328
( ) = inc mountings
depth
104 (122)
104 (122)
104 (122)
104 (122)
104 (122)
104 (122)
104 (122)
height
378 (420)
378 (420)
378 (420)
378 (420)
378 (420)
378 (420)
378 (420)
5
5
5
5
5
5
5
gas
15.88(5/8”)
15.88(5/8”)
15.88(5/8”)
19.05(3/4”)
22.22(7/8”)
28.58(1 1/8”)
28.58(1 1/8”)
liquid
9.52(3/8”)
9.52(3/8”)
9.52(3/8”)
9.52(3/8”)
9.52(3/8”)
12.7(1/2”)
15.88(5/8”)
weight (kg) PiPe siZe mm(in)
note: One air handling unit controller is required per air handling unit. Saturated refrigerant temperature at exit of evaporator = 8.5ºC, SH = 5K, liquid temperature = 25ºC, air = 27ºCDB/19ºCWB *1 When the diameter of the heat exchanger tube is ø9.52. *2 P400 and P500 are not compatible with PURY and PQRY. *3 If using in combination with standard indoor units, then these figures do not apply.
2-way blow cassette units
1-way blow cassette units ceiling concealed ducted units
aPPlicable outdoor units Puhy-P y(s)Jm-a Puhy-eP y(s)Jm-a Puhy-hP y(s)Hm-a Puhy-rP y(s)Jm-b PQhy-P y(s)Hm-a
Pury-P y(s)Jm-a Pury-eP y(s)Jm-a Pury-rP yJm-b PQry-P y(s)Hm-a
bc controllers
indoor units
example: air handling unit controller (mitsubishi electric)
PLP-6BA SLP-2AAW PLP-6BALM PLP-6BAJ PAC-SA1ME-E PAR-SA9FA-E S70E40714
- Grille for PLFY-P-VBM-E - Grille for PLFY-P-VCM-E2 - Grille and infra-red controller for PLFY-P-VBM-E - Grille with filter lowering function for PLFY-P-VBM-E - ‘I -See Sensor’ corner panel for PLFY-P-VBM-E - Infra-red signal receiver for PLFY-P-VBM-E - Infra-red Controller (PAR-SL97A-E) for PLFY-P-VBM-E
CMP-40VLW-C CMP-63VLW-C CMP-100VLW-C CMP-125VLW-C PAC-KH11OF
-
PMP-40BMW
- Grille for PMFY-P-VBM-E
PAC-KE04DM-F PAC-KE88LAF PAC-KE89LAF PAC-KE85LAF PAC-KE80TB-F PAC-KE140TB-F PAC-KE250TB-F
-
CMY-R160-J1 CMY-S202-J
- Joint pipe - Cover cap for CMB-PW202V-J
PAC-SE41TS-E
- Remote sensor
PAR-W21MAA THERM-10M
- Controller - Thermistor (10m cable)
Grille for PLFY-P20-40VLMD-E Grille for PLFY-P50-63VLMD-E Grille for PLFY-P80-100VLMD-E Grille for PLFY-P125VLMD-E OA duct flange for PLFY-P20-100VLMD-E
Drain lift-up mechanism for PEFY-P-VMH-E Long life filter for PEFY-P80VMH-E Long life filter for PEFY-P100-140VMH-E Long life filter for PEFY-P250VMH-E Filter box for PEFY-P80VMH-E (necessary when long life filter is used) Filter box for PEFY-P100-140VMH-E (necessary when long life filter is used) Filter box for PEFY-P250VMH-E (necessary when long life filter is used)
controller (field supplied)
vrF heat Pump boilers 220-240v, 50hz Power supply
m-net wiring
- Branch Pipe (Joint) for size 200 or below - total capacity of indoor units - Branch Pipe (Joint) for size 201-400 - total capacity of indoor units - Branch Pipe (Joint) for size 401-650 - total capacity of indoor units or first branch of (E)P450-P650 - Branch Pipe (Joint) for size 651 or above - total capacity of indoor units or first branch of P700-P1250 / EP700-EP900 - Branch Pipe for 2 branches (PUMY) - Twinning Kit for PUHY-P500-650YSJM-A / PUHY-EP400-600YSJM-A / PUHY-HP400-500YSHM-A / PQHY-P400-600YSHM-A - Twinning Kit for PUHY-P700-900YSJM-A CMY-Y200VBK2 - Twinning Kit for PUHY-P950-1250YSJM-A / PUHY-EP650-900YSJM-A / PQHY-P650-900YSHM-A CMY-Y300VBK2 - Twinning Kit for PUHY-RP400-650YSJM-B CMY-RP100VBK - Twinning Kit for PUHY-RP700-900YSJM-B CMY-RP200VBK - Twinning Kit for PURY-P450-650YSJM-A(1) / PURY-EP400-600YSJM-A CMY-R100VBK - Twinning Kit for PURY-P700-800YSJM-A CMY-R200VBK CMY-R100XLVBK - Twinning Kit for PURY-EP650-700YSJM-A CMY-R200XLVBK - Twinning Kit for PURY-P850-900YSJM-A - Twinning Kit for PQRY-P400-600YSHM-A CMY-Q100VBK - PQFY Auto-Changeover controller ACH1 - VRF AHU Interface (for use with 24v AC signals) ACH2 PAC-CN32WHMC-UK - Energy monitoring connector CMY-Y102S-G2 CMY-Y102L-G2 CMY-Y202-G2 CMY-Y302-G2 CMY-Y62-G-E CMY-Y100VBK2
air handling unit controllers / accessories
The Air Handling Unit Controller is an interface to allow connection to third party manufacturer equipment.
acoustic Kits for PUHY and PURY Series units
thermistor wiring
A range of Acoustic Kits designed for noise reduction. An industry first, the kits offer a 8dBA noise level reduction from standard.
Piping
For supply and / or installation please contact outdoor unit (mitsubishi electric)
Page 242
air handling unit (field supplied)
city multi Range
accessories / optional extras
Pac-ah-m-J
ambient acoustics on 01934 712802 Page 243
Lossnay Total Heat Exchangers
Air Conditioning Commercial Heating Domestic Heating Photovoltaics
Simple and Effective
Stale exhaust air
Heat exchange unit (Lossnay core)
Fresh air from outside
Excellent Air Quality and Unbeatable Heat Exchange Efficiency
Stale room air extracted
The Secret of the Lossnay System
Fresh air supply to the room
Poor air quality can be attributed to many problems arising in the workplace or in the home. It is believed to contribute to a significant loss in productivity, low morale and higher rates of sickness amongst many employees. The object of providing good ventilation alongside air conditioning in residential and commercial buildings is to provide conditions under which people can live and work in comfort and safety. Developed and refined over the past 35 years, the Lossnay system has perfected the recovery of energy that would have otherwise been wasted. The units reduce overall energy costs by extracting stale air and then recovering the heating or cooling energy to either warm or cool incoming fresh air. By utilising this energy, the Lossnay system can save up to 30% on initial capital costs of heating and cooling plant by reducing the load of the occupied space, resulting in the need for a smaller heating and/or cooling system.
The secret of the Lossnay system lies in the cross flow, plate fin structure of the heat exchange unit. A diaphragm made of specially processed paper fully separates inlet and exhaust air supplies, ensuring that only fresh air is introduced to the indoor environment.
Outdoors Stale dirty indoor air (Exhaust Air)
Indoors Fresh air into building (Supply Air)
Improvements to the Lossnay The microscopically small pores of the diaphragm have been made even smaller, decreasing the rate at which water soluble gases such as Ammonia and Hydrogen pass through. Further, a new specially processed paper used to make the diaphragm has been developed with high moisture permeability characteristics. This aids in the transfer of moisture and improves the effectiveness of shielding unwanted gases, resulting in highly efficient energy transfer.
Page 246
Fresh air introduction (Outdoor Air)
Stale air removed from building (Return Air)
Page 247
Main Features of
Total Heat Recovery Concept
Lossnay Effective Ventilation Lossnay’s simultaneous air exhaust/supply provides effective ventilation. Conventional ventilators (i.e. extract propeller fans) do not work effectively within air tight buildings because of the negative air pressures involved.
Good Energy Recovery
Good Sound Attenuation
Total heat (sensible and latent) recovery provides a comfortable air temperature within the room. The energy saved by using Lossnay contributes towards lowering the heating or cooling requirement within the building, therefore reducing the energy requirement and running costs.
As the Lossnay core is made of paper and the permeable holes are small, the Lossnay core provides outstanding soundproofing properties and is appropriate for sound proof rooms.
Free Cooling “By-pass” Function (LGH series) When the outdoor temperature is lower than the indoor air conditioned temperature in the summer, Lossnay provides fresh outdoor cool air to reduce the indoor air temperature.
Part L2 Building Regulations With the introduction of Part L2 (Part J in Scotland), new building design is changing to become more airtight, as well as energy efficient. The need for fresh air has remained the same however and thus poses new challenges for modern design. Lossnay fully meets these challenges due to its basic principal and its efficient heat recovery.
Operation in winter
Operation in summer
4°C
25.6°C
Stale warm air (exhaust)
Stale cool air (exhaust)
16°C
22.4°C
Fresh warm air (indoor supply air)
Fresh cool air (indoor supply air)
0°C
20°C
Fresh cool air (outdoor air)
Stale warm air (indoor air)
Heating unit
27°C
21°C
Fresh hot air (outdoor air)
Stale cool air (indoor air)
Cooling unit
Using a Lossnay LGH-100RX5 in the winter example above, 8.2kW of heat is recovered per hour from the extracted air.
Page 248
Page 249
Lossnay Working in Conjunction with Air Conditioning Lossnay units can work either on their own to provide fresh air into a room, or in combination with Mr Slim or City Multi ceiling cassettes and ducted units. When working together with air conditioning, Lossnay units can provide significant energy savings by automatically utilising free cooling as well as heat recovery. As the Lossnay and the air conditioning unit are connected by a two core communication cable, they can work together to optimise both comfort and energy efficiency. This is done by the Lossnay reading the mode and set temperature the air conditioning requires, then utilising the outside temperature to help achieve the required temperature either by free cooling or heat recovery.
Free Cooling was available in London over 58% of the time in 2006
When using Lossnay in conjunction with air conditioning the heating and cooling loads can be reduced significantly, reducing the running costs by up to 30% compared with air conditioning systems without heat recovery systems.
Above example: One LGH25RX5 serving one PLA-RP71BA. Room size 7m x 7m, 140w/m2 heat load. 7 people per room, 10litres/person of fresh air to meet Part F requirements. Maximum amount of fresh air to be introduced is 30% of the fan coil volume. Ceiling cassettes may require fresh air casements. Free cooling is not available below 8ยบC when interlocked with Mr Slim or City Multi units.
Lossnay fan speed button is incorporated within the standard PAR-30MAA and PAR-F27MEA controllers
Ambient Temperature - London 2006, 8am - 6pm The graph shows the hourly temperature for 2006 in London between 8.00am - 6.00p.m. The point to note is the amount of free cooling available during these hours, as well as the heat recovery below (22% of the time) and cooling recovery above (20% of the time). Lossnay is a year round solution for providing fresh air.
Over 58% of the time between 8am-6pm, the temperature in London was between 8ยบC and 20ยบC, allowing free cooling when the air conditioning setpoint was 21ยบC in cooling mode. If the setpoint is higher, free cooling is increased.
Page 250
Page 251
Hyper Eco Core LGH-RX5-E and LGH-RSDC-E Lossnay units feature the newly developed “Hyper Eco Core”, which uses non-porous, ultra-thin film to achieve high enthalpy exchange efficiency. With a thickness of only 25µm, these are the thinnest in the world and are approximately one fifth the thickness of previous Mitsubishi Electric products. Moisture permeability is dramatically increased and enthalpy heat exchange greatly improved.
Comparison of new and old Lossnay Core cross-sections Previous Lossnay Core
Comparison of material used in Hyper Eco Core (25µm ultra-thin film) with regular paper
New Hyper Eco Core
120µm
25µm
Porous partition plate
Non-porous film partition plate
The thinnest paper used in regular printing is 51µm thick (used in dictionaries) and the material of the Hyper Eco Core is approximately half the thickness of this. Use
Thickness 25µm
Hyper Eco Core material
Multi-Ventilation Mode Enables the appropriate supply/exhaust balance to be selected to suit usage, environment and location. Ventilation Mode
Previous Mitsubishi Electric material 120µm Photocopier paper
Ducts can be connected in two different directions to the outdoor vents thanks to collars and aperture plates that can be interchangeably placed in two different positions.
Standard installation
Installation with duct direction changed Can be installed close to the surface of the wall.
A space is necessary to prevent the influx of rainwater.
Changing the duct direction
Collar
All LGH-RX5-E models feature the "Multi-ventilation Mode," which allows the air supply/exhaust balance to be varied dynamically to suit the usage environment and location. Modes can be selected easily by setting the connectors on the circuit board.
Power air supply/exhaust mode
High
High
Power air supply mode
High
Low
Power air exhaust mode
Low
High
Energy-saving ventilation mode
Low
Low
* "High" can be further set to "Extra high" using the dip switch.
This flexibility allows for installations close to the surface of a wall and helps avoid cases where the stale air exhaust vent would be blocked by an obstruction of some kind. This makes both the planning and installation of Lossnay units that much simpler.
Page 252
51µm
Consists of a specially processed structure based on a single-layer, non-porous, ultra-thin film material. Moisture exchange (water vapour transmission) is promoted by the special film, which increases the affinity for moisture (the thinner the film, the higher the permeability). The non-porous ultra-thin film material acts as a barrier against air leakage.
Connect Ducts in Two Different Directions (Outdoor vents)
Exhaust Airflow
100µm
Dictionary paper
Consists of a two-layer construction using a specially processed material made of a preferential permeable film on a porous base material. This provides moisture permeability and air barrier properties, but the two-layer construction makes a certain thickness unavoidable.
Supply Airflow
Aper ture Plate
Exchangeable
CO2 Sensor
Extra Low mode (LGH-RX5-E)
Lossnay systems allow you to measure CO2 density (via an independent, 3rd par ty CO2 sensor) and thereby control the amount of fresh air supplied to a building. By connecting a CO2 sensor to the Lossnay unit, the system will switch fan speeds automatically depending on the CO2 level.
In addition to the conventional fan speeds, an Extra Low mode has been added to provide a more dynamic range of air volume settings. This provides versatility in a variety of installation environments, yielding better energy conservation.
Normal Office
Small Office or Building
Industrial Areas
Providing efficient ventilation while maintaining air supply/exhaust balance...
Using Lossnay compensates for using extractor fans...
Priority on air exhaust...
Power air supply & air exhaust
Power air supply
Power air exhaust
Most widely-used pattern forming the basis for traditional ventilation design. This allows the most efficient ventilation while maintaining the air supply/exhaust balance. The optimum ventilation rate can be maintained by selecting the Power air supply/exhaust mode with both the air supply & air exhaust switched to "High" (or "Extra high") on the main unit. For example in an office, the control switches can be set to "High" to run in Power air supply/exhaust mode when a large number of people are in the office, then switched to "Low" to run in Energy-saving ventilation mode late at night or on holidays when there are few people present.
In smaller offices or buildings, there may be insufficient air supply to the main rooms or offices due to the excessive exhaust via extractor fans located in toilets or kitchen areas. Setting to Power air supply mode with the air supply switch on "High" (or "Extra high") and the air exhaust switch on "Low" on the main unit, allows efficient ventilation while making up for the insufficient air supply.
In locations such as industrial working areas, dirty air must be exhausted swiftly. Setting the Power air exhaust mode with the air supply switch on "Low" and the air exhaust switch on "High" (or "Extra high") on the main unit allows efficient extraction of fumes and odours. Maintaining the area at a negative air pressure also prevents dirty air from spreading to surrounding areas.
Page 253
Restaurants
Schools
A restaurant can never be too clean and its air never too fresh
Creating the best possible environment for our children to succeed
The atmosphere of a restaurant is crucial to securing and retaining customers. Cleanliness is the key to an attractive atmosphere and restaurants devote significant effort to ensuring their premises are as such. Sanitation and cleanliness, however, are not enough. No matter how clean a restaurant may look, if there are bothersome odours lingering in the air, all those efforts go to waste and the restaurant's clean image is tarnished.
Children deserve all the help we can give them to grow up healthy, happy and prosperous. No matter how good a school's curriculum, no matter how positive and enthusiastic the teacher, a child who does not feel well will have a hard time learning. A constant flow of fresh air is nowhere as important as it is in our schools. In classrooms where large numbers of students are gathered for long periods of time, carbonic gases have the tendency to accumulate, decreasing the levels of oxygen that are vital for alertness and concentration.
For these reasons, Lossnay’s superior ventilation capabilities ensure that every breath is a fresh one and a pleasant environment is maintained for guests at all times. Lossnay also keeps owners happy with its remarkable heat recovery technology that supplies fresh outdoor air with minimal change to indoor temperature, saving on energy costs.
This is especially true during the winter months when windows tend to remain closed. Lossnay ventilates fresh outdoor air into classrooms to replenish the supply of oxygen and expels not only carbon dioxide, but also other pollutants and odours that inevitably sully the air.
If it’s Lossnay
If it’s Lossnay
Lossnay works to remove stale air and supply fresh, clean air free of the odours associated with cooking, cigarettes and the people working and dining.
The continuous influx of fresh, outdoor air and the exhaust of stale, indoor air ensure that the indoor oxygen level is maintained at just the right balance for comfort and health.
Change in room temperature is kept to a minimum during ventilation thanks to the heat-recovery function.
Occupants have the luxury of breathing fresh air at all times, even in highly air-tight buildings. Lossnay's sound attenuation qualities prevent outside noise from penetrating into the room, helping to maintain a quiet environment for productive study.
The Lossnay operate very quietly, so those in the midst of enjoying their meals will not be bothered by any excess noise.
O2 Concentration and Deficiency
What would you most like to see improved in restaurants?
52.3%
2
Page 254
6% Convulsions, respiration stops, death
0
8% Comatosis (death in 8 min)
5
10 % Paleness of skin, vomiting, Unconsciousness
10
Dizziness, nausea, loss of muscle strength (precursors of death)
12 % Increased respiration and pulse
1996 Foodstuffs Consumption Monitor, Second Periodic Survey ( Ministry of Agriculture, Forestry and Fisheries, Japan)
16 % 15
Safety minimum
Improvement in employees attitude towards customers: 20.5%
18 %
Normal air
Reduction of time required for food to reach the table: 12.0%
21 %
21
O2 Concentration (%)
Improvement in overall cleanliness
Offices
Heat-exchange technology prevents fluctuations in temperature creating significant energy savings when either heating or cooling a room.
A large array of Lossnay sizes are available to match the layout of just about any restaurant.
Others: no response Promotion of waste prevention: 5.4% Improvement in atmosphere: 6.5%
Occupants have the luxury of breathing fresh air at all times, even in highly air-tight buildings
If it’s Lossnay
Fresh air - improving the overall quality of working life Many office buildings today are heavily insulated, air-tight structures with little or no natural ventilation. The unnatural environment created by air conditioners without added ventilation is a breeding ground for bacteria. Factor this in with the accumulation of pollutants and odours in the form of formaldehyde, pollen, dust, carbon dioxide and the necessity of ventilation becomes ever more apparent. In fact, poorly ventilated buildings can give rise to Sick Building Syndrome, a malady that is known to cause headaches, sore eyes, itching and loss of concentration. This results not only in discomfort at best and sickness at worst for the building's occupants, but also the reduced productivity of the workforce. Fresh air, effectively ventilated throughout the building is therefore essential to the overall quality of working life.
Simultaneous forced-air supply and exhaust introduces fresh, outdoor air into the building, effectively ventilating even fully airtight structures. Multiple split-type units operate independently of one another, simplifying system set up and ensuring a layout that optimally matches nearly any office design. Lossnay operation can be interlocked with air-conditioning system operation. Heat that is commonly lost due to ventilation is collected and reused thanks to the Lossnay Core, reducing an air conditioners energy load and cutting operating costs.
Page 255
The Unbeatable
Lossnay
Contents 258
Total Heat Exchangers Residential Model
260
LGH-RSDC-E DC Lossnay Model
262
LGH-RX5-E Commercial Series
The Lossnay allows the extraction of stale air and efficient recovery of heating or cooling energy to treat incoming fresh air. Whatever your environment, it’s simple to improve it with Lossnay.
Simple technology at its best Many of our systems are registered on the Energy Technology List and hence qualify for 100% first year enhanced capital allowances. For further information please go to www.eca.gov.uk
Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB. Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB. UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. UK Conditions: Winter; indoor 21˚C DB; outdoor -1˚C WB.
Page 256
Page 257
Residential Model
VL 100U
Particularly suitable for modern homes with high insulation afforded by double glazing and cavity insulation, which require ventilation to remove stale air without major heat loss. I
Effective fresh air ventilation
I
Efficient recovery of heating/cooling energy
I
Good sound attenuation
I
Reduces heating costs
Lossnay Range
Total Heat Exchangers
Dimensions
Technical Information LOSSNAY MODEL REFERENCE
RESIDENTIAL WALL- MOUNTED VL 100U
ELECTRICAL POWER SUPPLY
220-240V, 50Hz
PHASE POWER CONSUMPTION (W) Low
23
High
26
Low
65
High
105
Low
29.5
High
39
Low
77
High
70
AIRFLOW (m3/h)
NOISE (dBA)
TEMPERATURE EXCHANGE EFFICIENCY (%) WEIGHT (kg) DIMENSIONS (mm)
DUCT SIZE (mm)
6.5 Width
620
Depth
168
Height
265 2xĂ&#x2DC;75
FUSE RATING (BS88) - HRC (A)
6
MAINS CABLE No. Cores
3
Page 258
Total Heat Exchangers Residential Model
Single
Page 259
DC Lossnay Model
Lossnay-5-FSC Interface
Particularly suitable for modern homes with high insulation afforded by double glazing and cavity insulation, which require ventilation to remove stale air without major heat loss. This model is also suitable for a number of non-residential applications such as schools.
I
Control up to 16 DC Lossnay units
I
Automatic fan speed control based on CO2 level (5 speeds)
I
Effective fresh air ventilation
I
Interlock with a PIR sensor or switch
I
Efficient recovery of heating/cooling energy
I
Interlock with a CO2 sensor or BEMS (0-10v DC)
Good sound attenuation
I
I
Dimensions (WxDxH) mm: 160x80x120
I
Reduces heating costs
I
Low power consumption with 5 variable fan speeds
I
New “Hyper Eco Core” facilitating improved humidity penetration
I
By-pass mode for ‘free cooling’. Including new power mode to supply a greater volume of fresh, cool air - for instance during summer nights
I
SAP Appendix Q eligible
I
Optimise the fan speed based on CO2 level using the Lossnay-5-FSC interface
Lossnay Range
LGH-RSDC-E
Dimensions
LGH-50RSDC-E Front View
>
Upper View
Technical Information
Left Side View
>
> Right Side View
>
LOSSNAY MODEL REFERENCE
LGH-50RSDC-E
220-240V, 50Hz
ELECTRICAL POWER SUPPLY
2
STARTING CURRENT (A) LOSSNAY
BYPASS
1
2
3
4
5
POWER
1
2
3
4
5
INPUT POWER (W)
172
92
42
23
14
279
172
92
42
22
14
AIRFLOW (m3/h)
445
340
240
160
100
520
445
340
240
160
100
AIRFLOW (l/s)
124
94
67
44
28
144
124
94
67
44
28
EXTERNAL STATIC PRESSURE (Pa)
75
45
25
10
5
102
75
45
25
10
5
NOISE (dBA)
31
26
21
18
18
35
31
26
21
18
18
TEMPERATURE EXCHANGE EFFICIENCY (%)
75
80
84.5
87.5
90
-
-
-
-
-
-
Heating
68.5
73.5
78
81.5
83.5
-
-
-
-
-
-
Cooling
65.5
71
76
79.5
82.5
-
-
-
-
-
-
FAN SPEED
ENTHALPY EXCHANGE EFFICIENCY WEIGHT (kg) DIMENSIONS (mm)
DUCT SIZE (mm)
45 Width
1099 + 73
Depth
898
Height
302
>
200
FUSE RATING (BS88) - HRC (A)
6
MAINS CABLE No. Cores
3
Page 260
Rear View
LGH-50RSDC-E DC Lossnay Model
VENTILATION MODE
Page 261
Dimensions
Commercial Series
LGH-15RX5-E to LGH-200RX5-E
This commercially orientated system can be utilised virtually anywhere.
Lossnay Controller PZ-60DR-E
I
Effective fresh air ventilation
I
High heat recovery
I
Free cooling function
I
Good sound attenuation
I
New “Hyper Eco Core”. At only 25µm the Lossnay core uses the thinnest paper in the world to achieve high enthalpy exchange efficiency
I
The Lossnay-5-FSC Interface can also be used with LGH-RX5-E units. However, automatic fan speed control is with 3 speeds
Technical Information
LGH-15-100RX5-E
I
Control up to 15 Lossnay units
I
New dot matrix display
I
Weekly timer (ability to pre-set air volume requirements at different intervals)
I
Night purge function
I
Dimensions (WxDxH) mm: 130x19x120
>
LGH-150-200RX5-E
Lossnay Range
LGH-RX5-E
>
LOSSNAY
High
Notes: Running Current, Input Power and Recovery Efficiency are based on the above airflow rate, power supply 240v, 50Hz. Extra High and High mode available via dip switch setting. Extra Low mode not available on sizes 150 and 200. Noise measured at 1.5m under the centre of panel. *1: EU-F7 filter available as optional parts.
Page 262
By-pass damper plate
By-pass damper plate Air exhaust fan
RA (return air)
EA (exhaust air outlet)
1010
EA (exhaust air outlet)
RA (return air) B C
A 270
LOSSNAY core
Inspection opening
Air supply fan Control box
C
Maintenance cover High efficiency filter(sold separately) attachment position
Core, air filter, HighEfficiency filter, fan, Maintenance space
Inspection opening
Air supply fan
399 798
Control box
Power supply cable opening
Maintenance cover
A
High efficiency filter(sold separately) attachment position
LOSSNAY core 44
Position where duct direction change is possible
SA (supply air) 27
Core, air filter, HighEfficiency filter, fan, Maintenance space
OA (outside air intake)
150~250
SA (supply air) Power supply cable opening
OA (outside air intake)
Ceiling suspension fixture (4-15x30 oval)
110
Ceiling suspension fixture (4-13x20 oval)
270
Air exhaust fan
D
More than 600
220-240V, 50Hz 220-240V, 50Hz 220-240V, 50Hz 4.6 7.3 11.9 0.90 1.70 2.90 3.40 2.10 3.20 4.20 2.40 3.50 4.80 200 380 680 785 475 740 980 535 830 1100 415 755 1300 1580 1000 1500 2000 115 210 361 439 278 417 556 18 60 100 65 110 135 105 170 175 165 22 32.5 35 34 35 37.5 38 37 39 40 22 33 37 35 36 39 39 38 40.5 41 87 83 81 83 80 80 80 80 80 80 80 74 72.5 73.5 72.5 72 72.5 79 73 71.5 72 71 70.5 71 59 105 118 1231 1004 1231 1144 1144 1144 399 798 798 (SA,RA)250 (OA,EA)270x700 (SA,RA)250 (OA,EA)270x700 250 EU-G3 EU-G3 EU-G3 10 16 6 3 3 3
E
220-240V, 50Hz 3.8 0.65 1.45 1.60 1.75 145 340 370 415 355 700 800 99 194 222 20 95 120 150 22 31 33 34.5 22 32 34 35.5 87.5 80.5 79 79 79.5 72.5 71 79.5 71.5 70 53 1004 1144 399 250 EU-G3 6 3
B
220-240V, 50Hz 4.4 0.60 1.20 1.50 1.80 140 265 322 380 265 520 650 74 144 181 8 50 80 120 22 31.5 33 34.5 22.5 30.5 33.5 35 86 80 77 77 78 70.5 68.5 77 68.5 66 40 954 908 386 200 EU-G3 6 3
150 ~250
220-240V, 50Hz 3.0 0.40 0.85 1.00 1.25 95 190 228 286 180 390 500 50 108 139 10 60 90 155 19 28 32 34 19 29 32.5 35 86 81 78 78 78 71 69 77 68 66.5 32 1016 888 315 200 EU-G3 6 3
1144
79
Air filters (EU-G3)
Air filters(EU-G3)
LGH RX5-E Commercial Series
High
220-240V, 50Hz 2.4 0.30 0.51 0.74 0.92 69 116 169 212 115 210 350 32 58 97 9 30 80 160 18 23 29.5 32 18 24 30.5 32.5 88 85 80 80 81.5 76.5 71.5 81 75.5 71 29 874 888 315 150 EU-G3 6 3
242 258
High
220-240V, 50Hz 0.9 0.18 0.27 0.48 0.55 42 62 114 129 105 155 250 29 43 69 9 25 60 85 19 21.5 26 27 19 22 26.5 27.5 83.5 81.5 79 79 77.5 74 69.5 76 72.5 68 20 735 780 273 150 EU-G3 6 3
242 258
High
220-240V, 50Hz 0.8 0.15 0.25 0.38 0.46 35 59 90 110 70 110 150 19 31 42 14 40 70 105 18 23.5 27 28 19 24 28 29 85.5 84 82 82 81 77.5 75 81 76.5 73 20 735 780 273 100 EU-G3 6 3
More than 600
ELECTRICAL POWER SUPPLY STARTING CURRENT (A) RUNNING CURRENT (A) Extra Low Low High Extra High INPUT POWER (W) Extra Low Low High Extra High AIRFLOW (m3/h) Extra Low Low High / Extra AIRFLOW (l/s) Extra Low Low High / Extra EXTERNAL STATIC Extra Low PRESSURE (Pa) Low High Extra High NOISE (dBA) Lossnay Extra Low Low High Extra High Bypass Extra Low Low High Extra High TEMPERATURE Extra Low EXCHANGE Low EFFICIENCY (%) High Extra High ENTHALPY Heating Extra Low EXCHANGE Low EFFICIENCY (%) High / Extra Cooling Extra Low Low High / Extra WEIGHT (kg) DIMENSIONS (mm) Width Depth Height DUCT SIZE (mm) 1 * STANDARD FILTER FUSE RATING (BS88) – HRC (A) MAINS CABLE NO. CORES
Position where duct direction change is possible
COMMERCIAL COMMERCIAL COMMERCIAL COMMERCIAL COMMERCIAL COMMERCIAL COMMERCIAL COMMERCIAL COMMERCIAL LGH-15RX5-E LGH-25RX5-E LGH-35RX5-E LGH-50RX5-E LGH-65RX5-E LGH-80RX5-E LGH-100RX5-E LGH-150RX5-E LGH-200RX5-E
700
MODEL REFERENCE
Notes: Please use the Lossnay Technical Databook for specific, individual model schematics.
MODEL REFERENCE A
DIMENSIONS B
C
LGH-15RX5-E
780
735
273
768
782
Ø100
LGH-25RX5-E
780
735
273
768
782
Ø150
LGH-35RX5-E
888
874
315
875
921
Ø150
LGH-50RX5-E
888
1016
315
875
1063
Ø200
LGH-65RX5-E
908
954
386
895
1001
Ø200
LGH-80RX5-E
1144
1004
399
1010
1036
Ø250
LGH-100RX5-E
1144
1231
399
1010
1263
Ø250
MODEL REFERENCE
A
B
C
LGH-150RX5-E
1004
690
1045
LGH-200RX5-E
1231
917
1272
CEILING SUSPENSION FIXTURE PITCH D E
NOMINAL DIAMETER E
Page 263
Lossnay Range
Accessories / Optional Extras M Series High Efficiency Filter
PZ-25RFM
- for LGH-15RX5-E / LGH-25RX5-E
PZ-35RFM
- for LGH-35RX5-E
PZ-50RFM
- for LGH-50RX5-E
PZ-65RFM
- for LGH-65RX5-E
PZ-80RFM
- for LGH-80RX5-E / LGH-150RX5-E (2 sets)
PZ-100RFM
- for LGH-100RX5-E / LGH-200RX5-E (2 sets)
Accessories / Optional Extras
The High Efficiency Filter (with 65% colorimetricity EU-F7) can be incorporated inside the Lossnay LGH-RX5-E unit easily
Page 264
Controls A Comprehensive Range of Control Options
Air Conditioning Commercial Heating Domestic Heating Photovoltaics
The Importance of Control The need for control is paramount in order to optimise the performance of any air conditioning system and minimise its running costs and the emissions generated. Mitsubishi Electric offer a wide range of control options designed to do just this. Operating an air conditioning system without the right control can prove costly. Itâ&#x20AC;&#x2122;s therefore important to ensure that every system is correctly specified to the degree of control it requires. Mitsubishi Electric have a wide range of controls available â&#x20AC;&#x2DC;off-the-shelfâ&#x20AC;&#x2122; and where needed, individual control systems can be specifically designed to suit. Good controls will benefit any application, large or small. Air conditioning products need to react to a variety of factors: different room sizes, usage and staff levels, changes in the climate, electronic equipment and lighting etc. The ability to monitor the energy consumption and operation of systems is also vital. It is often said that you cannot manage what you are not measuring. Our control systems will enable simple measuring and monitoring of energy consumption and running costs to ensure operation is maintained.
Controlled Performance In accordance with the requirements of Part L2 in the Building Regulations, our control systems provide the optimum control available, combined with the most efficient use of energy.
A Degree of Difference When an air conditioning system is not properly controlled, it will not run as efficiently as it should. For every degree that the system deviates from the required temperature, energy costs can rise by up to 5%. Specify one of the many control options from Mitsubishi Electric to ensure air conditioning works as intended, whilst giving the optimum amount of control.
The Simpler the Better With the array of comprehensive control systems available from Mitsubishi Electric, it becomes simple to design and install air conditioning systems. From a simple hand held controller to an AG150 system - you are in control.
So whatever the application, optimum control of air conditioning systems is essential and will result in a constant, comfortable environment, which in turn is both energy and cost efficient.
Page 266
Page 267
Which Controls Product for Which Application?
Which Controls Product for Which Function?
It is really important to match the right control with the right application. From a hotel to a retail application, the solution will be different and the right control must be applied. Application
Small
Medium
Application
Large
Notes
MELCOTEL
A hotel usually requires interfacing with a key card system and window contact. The Melcotel has been designed to do just this for up to 250 City Multi indoor units. The Melcotel can also work without a key card system
TM
Hotel
AG150
MELCOTEL
TM
TM
TM
Office
Retail
Leisure
Education
PAR-30MAA PAR-F27MEA
IO Interface
PAR-30MAA PAR-F27MEA Mini M2M PAR-30MAA PAR-F27MEA Mini M2M
AG150
Mini M2M
AG150 Maxi M2M
AG150 Maxi M2M
TG2000
Maxi M2M
AG150 TG2000
AG150 TG2000
In an office application there is usually someone managing the air conditioning, so the interface needs to be simple to use. The user friendly AG150 touch screen is one option, as well as the TG2000 PC graphical user interface Retail shops are usually managed by head offices or facility management companies, so it is key to have remote monitoring of the air conditioning, but also any building services which can also be connected to the M2M interfaces In small applications the M2M platform can be a solution, as well as the AG150 touch screen or the TG2000 software package for larger applications In small applications the M2M platform can be a solution, as well as the AG150 touch screen or the TG2000 software package for larger applications
Low
Cost and Features
High
Notes
Option 1
Option 2
Option 3
Option 4
Option 5
Remote On/Off or fire alarm
PAC-SA89TA
TCB1
IO Interface
AT50
AG150 and PAC-YG10HA
On/Off remote controller button lock except TCB1
Monitor run and faults
PAC-SA88HA
IO Interface
AT50
AG150 and PAC-YG10HA
-
Relays or power supply may be required
Window interlocking
PAC-SA89TA
TCB1
-
-
-
Controller will be centrally controlled when window opened
Setpoint limit
PAR-30MAA
PAR-F27MEA
AT50
AG150
AG150 and TG2000
Available in Heat, Cool and Auto modes
Weekly timer
PAR-30MAA
AT50
AG150
AG150 and TG2000
M2M
Setpoint, On/Off can be reset
Night set back
TCB1
AT50
AG150
AG150 and TG2000
M2M
TCB1 requires thermostat, timeswitch, 12v power supply
Energy monitoring
AG150 and AG150 and PAC-CN32WHMC-UK PAC-YG60MCA
TG2000, AG150 and PAC-YG60MCA
Mini M2M
Maxi M2M
Different options for each choice. Meters required
Load shedding
AG150 and PAC-YG60MCA
Mini M2M
Maxi M2M
-
-
Energy meters required
Trend logging
AG150 and TG2000
Mini M2M
Maxi M2M
-
-
CSV data available on a spreadsheet
Night mode
PAC-SA89TA
AG150
-
-
-
PAC-SA89TA requires a third party timer
Ambient tracking
AG150 and PAC-YG63MCA
Mini M2M
Maxi M2M
-
-
PT100 sensor required
Key card interlock for hotel
AG150, MELCOTEL AG150-Interlock and PAC-SA89TA and PAC-SA89TA
-
-
-
Volt free contact for key card normally open
Window sensor interlock for hotel
MELCOTEL and PAC-SA89TA
-
-
-
-
Volt free contact for key card normally closed
2 setpoints (1 for cool and 1 for heat)
IO Interface
Mini M2M
Maxi M2M
-
-
For instance, 19ยบC Heat and 23ยบC Cool. Fan only in between
Duty / Standby
PAR-30MAA
PANEL_RS_SMS -
-
-
Backup, rotate, join in and high temperature function
A/C faults via SMS
Micro M2M
-
-
-
-
SIM card not supplied
Optimised start
AG150
-
-
-
-
-
Mini BEMS
Mini M2M
Maxi M2M
-
-
-
-
TM
TM
NOTE: The PAC-SA89TA is also known as a 3 wire adaptor and the PAC-SA88HA is also known as a 5 wire adaptor DISCLAIMER: These options are for guidance only
Page 268
Page 269
A Wide Range of Control Options The need for control is paramount in order to optimise the performance of any air conditioning system and minimise its running costs. Mitsubishi Electric offer a wide range of control options designed to do just this. With the array of comprehensive control systems available from Mitsubishi Electric, it becomes simple to design and install air conditioning systems. From a simple hand held controller to an AG150 system you are in control.
Page 270
Contents 272
Remote Controllers
290
TG2000 WAN Software (Wide Area Network)
273
AT50 Controller, Centralised Controller
291
TG2000, Screenshots
274
Interfaces
292
BEMS BACnet Interface (BAC-IP/50)
275
IO Interface
293
BEMS BACnet Interface (BAC-HD150)
276
AG150 Controller, Centralised Controller
294
BEMS BACnet Mr Slim Interface (BAC-A/50)
277
AT50/AG150 Controller, Touch Screen Examples
295
BEMS LonWorks Interface (LMAP)
278
AG150 Expansion Controller (PAC-YG50ECA)
296
BEMS Modbus Interface (MOD-IP/50)
279
GB50ADA Controller, Centralised Controller
297
BEMS Modbus Mr Slim Interface (A32M)
280
AG150/GB50 Controller, Web Screenshots
298
BEMS Modbus Splits Interface (A1M)
281
PAR-21PC Desktop Remote Controller
299
BEMS KNX-EIB Interfaces (KNX-EIB-IP-15/100)
282
AG150/GB50 Third Party Equipment Interfaces
300
BEMS KNX-EIB Splits Interface (KNX-EIB-A-1)
283
AG150/GB50 Melcotel Hotel Interface, with key card system
301
BEMS Trend Interface (Trend IQ3 Excite)
302
284
AG150/GB50 Melcotel Hotel Interface, without key card system
M2M - Machine 2 Machine Interface (Maxi M2M-IP/50)
303
285
AG150/GB50 Melcotel Hotel Interface, with M2M
M2M - Machine 2 Machine Splits Interface (Mini M2M-A/16)
304
286
TG2000 Software, PC Based Software Package
M2M - Machine 2 Machine Splits Interface (Micro M2M-SMS-A/08)
287
TG2000 Software with Energy Monitoring
305
M2M - Machine 2 Machine Web Screenshots
288
Energy Monitoring
306
Run Standby Panel (PANEL_RS_SMS)
289
TG2000 Software with Third Party Equipment
307
Split-System A2M Interfaces
TM
TM
TM
速
速
速
速
Page 271
AT50 Controller
Our air conditioning systems are supported by a multitude of remote controllers. Each remote controller type, whilst being able to support the general control and monitoring functions for a group of indoor units, can also offer other unique operational features.
PAC-SE51CRA
BS-51COV-B
PS-51COV-B
PB-51COV-B
PAR-30MAA
PAR-F27MEA
PAR-FL32MA
Technical Information Remote Controllers FUNCTION
DESCRIPTION
ON/OFF
Run and Stop operation for a single group
MODE SELECTION
Switches between Cool/Dry/Auto/Fan/Heat. Operation mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems
PAC-YT51CRB PAC-SE51CRA
PAR-30MAA
Display
Operation
Display
Operation
Display
Operation
Display
Operation
Display
Sets the groups temperature control. Cool/Dry: 19-30°C Heat: 17-28°C Auto: 19-28°C
FAN SPEED SETTING
4 speed - Lo-Mi1-Mi2-Hi 2 speed - Lo-Hi
SETPOINT LIMIT
Limit the setpoint range
AIRFLOW DIRECTION INDEPENDENT VANE CONTROL
AT50
Air Flow angles:100º-80º-60º-40º and auto swing
Only available with PLA-RP-BA, PLFY-P-VBM-E and PLFY-P-VCM-E
Daily
TIMER OPERATION
ON/OFF time can be set.
PERMIT / PROHIBIT FUNCTION
Run/Stop, Temperature Setting, Mode Selection and Filter Reset functions can be prohibited via a higher level system controller
INDOOR RETURN AIR TEMPERATURE
Measures the intake temperature of the master unit within the group
ERROR INDICATION
Displays a 4 digit code and the affected unit address
TEST RUN FUNCTION
Allows each unit within the group to operate in test mode
VENTILATION INTERLOCK
Allows the group to be interlocked with a heat recovery Lossnay unit
OPTIONAL COVER
Brushed Stainless Steel Polished Stainless Steel Polished Brass
CONTACT NUMBER UNDER FAULT CONDITIONS
Displays under fault condition, the fault code of the unit with its address and the contact number to call
EASY MAINTENANCE WITH MR SLIM
Able to monitor info about the compressor (running current, running time, On/Off time). Also able to monitor sensors: h-exh, OU outlet, OU temp, IU inlet, IU h-exh and filter usage
BACKLIGHT DISPLAY
Backlight display. Displays current time
BUTTON LOCK
Able to lock all controller buttons, or all controller buttons except On/Off
Daily
Daily
Daily
PAC-SC51KUA
Technical Information Weekly
Weekly
Reset the unit setpoint after a period of time
SILENT MODE
Activate with scheduling the silent mode on the outdoor unit
NIGHT SET BACK
Maintain a min and max temperature
RUN / STANDBY WITH MR SLIM
Able to switch over two systems every week. If one fails, the other system starts. If the temperature is too high, the two systems start.
COMPATIBILITY
Compatible with:
AT50 Controller FUNCTION
DESCRIPTION
TOUCH SCREEN
5” QVGA touch screen
MAX No. OF INDOOR UNITS
Up to 50 indoor units can be connected
ON/OFF
Run and Stop operation for a single group
MODE SELECTION
Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems
TEMPERATURE SETTING
Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C
TIMER OPERATION
Annual or weekly. Night set back option available allowing the setpoint to be set to 12ºC
AIR FLOW DIRECTION
Air Flow angles:100º-80º-60º-40º and auto swing
FAN SPEED SETTING
4 speed: Lo-Mi1-Mi2-Hi, 2 speed: Lo-Hi
PERMIT/PROHIBIT FUNCTION
Individual prohibit operations for each remote controller function (Run/Stop,Temperature Setting, Mode Selection and Filter Reset) can be activated
INDOOR RETURN AIR TEMPERATURE
Displays the measured intake temperature from each group
ENERGY SAVING
Page 272
PAR-FL32MA
Operation
TEMPERATURE SETTING
DIMENSIONS - mm (WxDxH)
PAR-F27MEA
ERROR INDICATION
Displays a 4 digit code and the affected unit address. An error log is held
TEST RUN FUNCTION
Allows each unit within the group to operate in test mode
VENTILATION INTERLOCK
Allows the group to be interlocked with a heat recovery Lossnay unit
FIRE ALARM
Units will be switched off and the remote controller will be locked under fire alarm condition
NIGHT SET BACK
During unoccupied hours the system works in a reduced state. For instance, an unoccupied room in heating mode will keep the temperature of the room between 16 and 19°C. In cooling the temperature will range between 24 and 26°C
POWER SUPPLY
Power supply 240VAC 0.5A (PAC-SC51KUA required)
COMPATIBILITY
City Multi or Mr Slim via PAC-SF81MA or M Series via MAC-399IF
DIMENSIONS - mm
Mr Slim or M Series (via MAC-397IF)
City Multi, Mr Slim (via PAC-SF81MA) or M Series (via MAC-399IF)
City Multi, Mr Slim or M Series (via MAC-397IF)
City Multi, Mr Slim (via PAC-SF81MA) or M Series (via MAC-399IF)
City Multi (via PAR-FA32MA) or Mr Slim (via PAR-FA32MA)
120x41x70
120x41x70
120x19x120
130x19x120
157x18x57
(WxDxH)
180x30x120
Page 273
Remote Controllers / AT50 Controller
PAC-YT51CRB
The new AT50 centralised controller is a low cost version of the very popular AG150 touch screen controller. The AT50 offers the main AG150 functionality, with a very simple and easy to use 5 inch touch screen.
Controls Range
Remote Controllers
IO Interface The new IO interface has been developed to allow third party systems, for instance BEMS companies, to easily control and monitor our air conditioning systems using simple volt free contacts and 0 to 10VDC signals. By working very closely with our main retail clients we have added some beneficial energy saving features, whilst still offering an acceptable level of control for retail applications. To avoid wasting energy the IO interface can also be used to interlock third party heating systems to our air conditioning.
A range of newly created interfaces are now available for use when connecting to third party controllers.
PAC-SA89TA
IO Interface
TCB1
PAC-SA88HA
Controls Range
Interfaces
Technical Information IO Interface
TCB1
PAC-SA88HA
Technical Information Interfaces FUNCTION
DESCRIPTION
PAC-SA89TA Control
ON/OFF BUT CENTRALLY CONTROLLED
ON/OFF control. Remote controller ON/OFF button deactivated
ON/OFF BUT NOT CENTRALLY CONTROLLED
ON/OFF control. Remote controller ON/OFF button activated
TEMPERATURE SETTINGS
Sets the groups temperature control. Cool/Dry: 19-30°C Heat: 17-28°C Auto: 19-28°C
Monitor
PAC-SA88HA Control
Monitor
(12VDC)
(12VDC)
ERROR INDICATION
(12VDC) Interface compatible with:
DIMENSIONS - mm (WxDxH) NOTE: VFC: Volt free contact. PAC-SA89TA is also known as a 3 wire adaptor. PAC-SA88HA is also known as a 5 wire adaptor.
Monitor
(VFC)
RUN INDICATION
COMPATIBILITY
TCB1 Control
Mr Slim City Multi
Mr Slim City Multi
Mr Slim City Multi 80x45x80
DESCRIPTION
INPUTS / OUTPUTS
IO INTERFACE
UNIT
Max No. of indoor units
-
1 or 16*1
ON/OFF
Run and Stop operation for a single group
Input
Volt Free Contact
LOCK
Run/Stop, Temperature Setting, Mode Selection and Filter Reset functions can be prohibited
Input
Volt Free Contact
ENERGY SAVE
Energy Save can be activated. 2 options are available
Input
Volt Free Contact
TEMPERATURE SETTING
Sets the groups temperature control
Input
0 to 10VDC
MODE
Switches between Cool/Dry/Auto/Fan/Heat. Operation mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems
Input
0 to 10VDC
FAN SPEED
4 speed - Lo-Mi1-Mi2-Hi 2 speed - Lo-Hi
Input
0 to 10VDC
RUN STATUS
-
Output
Volt Free Contact
FAULT
-
Output
Volt Free Contact
HEAT / COOL
Activates when unit is in heating or cooling mode
Output
Volt Free Contact
THERMO
Activates when room temperature is 2ºC away from setpoint
Output
Volt Free Contact
COMPATIBILITY
Mr Slim and M Series
-
-
DIMENSIONS - mm (WxDxH)
85x32x138
-
-
Energy Saving Features MODE 1
MODE 2
The energy saving mode 1 sets the indoor unit to Auto mode whenever a momentary signal is applied to the ‘Energy Save’ input or whenever the on/off state is changed from OFF to ON. The unit will operate in AUTO for 0.5, 1 or 2hours and then revert back to fan only.
The energy saving mode 2 sets two setpoints for the indoor unit, one for heating and one for cooling. In between the indoor unit will be running in fan only mode.
The timer can be reset using the Energy Save input.
OFF
AUTO
09.00
OFF
AUTO
09.00
Page 274
11.00
11.00
FAN 13.00
FAN
15.00
AUTO
OFF 17.00
FAN
13.00 15.00 17.00 Active via push button
19.00
OFF 19.00
25 24 23 22 21 20 19 18
COOLING MODE
FAN ONLY MODE
HEATING MODE
*1 The IO Interface can control up to 16 indoor units when the fault output is not used. When the fault output is used only one indoor unit can be controlled.
Page 275
Interfaces / IO Interface
PAC-SA89TA
FUNCTION
AT50/AG150 Controller Touch Screen Examples
Touch Screen Centralised Controller with WebServer Capabilities
AT50 Home Screen 1
AG150 Home Screen 1
AT50 Home Screen 2
AG150 Home Screen 2
AT50 Home Screen 3
AG150 Home Screen 3
AT50 Indoor Unit Settings
AG150 Indoor Unit Settings
AT50 Scheduling
AG150 Scheduling
The AG150 Mitsubishi Electric centralised controller offers a large 9 inch touch screen display with easy control of up to 50 indoor units. The AG150 can calculate the energy used for each system. The refrigerant status check function can be activated regularly (in conjuction with the new YJM-A City Multi range) and an Internet connection with SSL security is also available to monitor and control the AG150 remotely and receive Email under fault conditions.
ETHERNET
M-NET
AG150 PAC-SC51KUA
Viewed using Microsoft® Internet Explorer
Technical Information
Controls Range
AG150 Controller
DESCRIPTION
TOUCH SCREEN
Wide high resolution 9” touch screen
OPERATION PLATFORM
CPU 1000 Mhz, 512 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2 or Windows Vista or Windows 7
MAX No. OF INDOOR UNITS
Up to 50 indoor units can be connected or 150 using an expansion controller (PAC-YG50ECA)
ON/OFF
Run and Stop operation for a single group
MODE SELECTION
Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems
TEMPERATURE SETTING
Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C
TIMER OPERATION
Annual or weekly. Night set back available allowing the setpoint to be set to 12ºC
AIR FLOW DIRECTION
Air Flow angles:100º-80º-60º-40º and auto swing
FAN SPEED SETTING
4 speed: Lo-Mi1-Mi2-Hi, 2 speed: Lo-Hi
PERMIT/PROHIBIT FUNCTION
Individual prohibit operations for each remote controller function (Run/Stop,Temperature Setting, Mode Selection and Filter Reset) can be activated
INDOOR RETURN AIR TEMPERATURE
Displays the measured intake temperature from each group
ERROR INDICATION
Displays a 4 digit code and the affected unit address including the description of the error. An error log is held
TEST RUN FUNCTION
Allows each unit within the group to operate in test mode
VENTILATION INTERLOCK
Allows the group to be interlocked with a heat recovery Lossnay unit
OPTIMISED START
The equipment is started only as early as required to bring the building to a setpoint at the time it will be occupied. Running in an optimal state helps reduce energy usage.
AUTOMATIC SETPOINT ADJUSTMENT
The AG150 will change the setpoint depending of the outdoor temperature. PAC-YG63MCA and a PT100 sensor are required (PT100 sensor not supplied by MEUK). This function is only available in COOL mode
AUTO LOCK
The AG150 screen can be password protected. When the screen goes to standby and when the AG150 restarts, a username and password will be required
NIGHT SET BACK
During unoccupied hours the system works in a reduced state. For instance, an unoccupied room in heating mode will keep the temperature of the room between 16 and 19°C. In cooling the temperature will range between 24 and 26°C
AutoCAD DRAWING
A floor plan of the building in auto-cad format can be uploaded. For the facilities department it makes viewing and adjusting settings easier
WEB LOGIN
Administrator able to allow specific function access to guest
WEB SETPOINT LIMIT
Reduce the setpoint band of each individual unit (e.g. 23ºC to 25ºC)
WEB AUTO CHANGEOVER
Automatically switch heat pump outdoor unit to cooling or heating mode depending on the requirements
WEB INITIAL SETTING
Commission the AG150 from the web pages
WEB REFRIGERANT STATUS CHECK
Activate refrigerant volume checking function on Modular City Multi systems
WEB-INTERLOCK
The AG150 can interlock indoor unit input and output together. For instance, this function could be used for Hotel applications, if card in, set unit to ON, AUTO 21ºC and if card out, set the unit to night set back. This function could also be set in conjunction with PIR sensor in meeting rooms
WEB-LOAD SHEDDING
Activate energy saving mode when energy consumption is too high
EXTERNAL INPUT/OUTPUT
Hardwired connections are available for :
Inputs: Outputs:
Level Signal-Batch Start/Stop, Batch Emergency Stop Start/Stop Status, Error/Normal Status
FIRE ALARM
Units will be switched off and the remote controller will be locked under fire alarm condition via a PAC-YG10HA
POWER SUPPLY
Power supply 240VAC 0.5A (PAC-SC51KUA required)
COMPATIBILITY DIMENSIONS - mm
City Multi or Mr Slim via PAC-SF81MA or M Series via MAC-399IF (WxDxH)
300x62x175
AG150 Software Options - Pin Code Activation
DEMONSTRATION
Web monitoring, Email, Annual scheduling AG150 - VRC Virtual remote controllers AG150 - Basic AG150 - Energy Energy monitoring, energy saving, load shedding AG150 - Interlock Interlocking function
Visit wwwL1.mitsubishielectric.co.jp/ wink_doc/wink_files/acr/menu/ag150
Page 276
AG150 Controller / AT50/AG150 Controller Touch Screen Examples
AG150 Controller FUNCTION
Page 277
PAC-YG50ECA AG150 Expansion Controller
Centralised Controller with WebServer Capabilities
The PAC-YG50ECA expansion controller allows the AG150 to monitor and control up to 150 indoors units.
The GB50 has been developed to access all your control functions from the comfort of your own PC, without the need for a controller keypad or LCD display and at a very competitive price.
Controls Range
GB50ADA Controller
M-NET
AG150
ETHERNET GB50ADA
ETHERNET
PAC-YG50ECA
PAC-YG50ECA
Viewed using Microsoft® Internet Explorer
Technical Information
PAC-SC51KUA
FUNCTION
DESCRIPTION
OPERATION PLATFORM
CPU 1000 Mhz, 512MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2 or Windows Vista or Windows 7
MAX No. OF INDOOR UNITS
Up to 50 indoor units can be connected
ON/OFF
Run and Stop operation for a single group
MODE SELECTION
Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems
TEMPERATURE SETTING
Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C
FAN SPEED SETTING
4 speed: Lo-Mi1-Mi2-Hi, 2 speed: Lo-Hi
AIR FLOW DIRECTION
Air Flow angles:100º-80º-60º-40º and auto swing
TIMER OPERATION
Annual or weekly. Night set back option available allowing the setpoint to be set down to 12ºC
PERMIT/PROHIBIT FUNCTION
Individual prohibit operations for each remote controller function (Run/Stop,Temperature Setting, Mode Selection and Filter Reset) can be activated
INDOOR RETURN AIR TEMPERATURE
Displays the measured intake temperature from each group
PAC-YG50ECA
HUB
Technical Information
PAC-YG50ECA NUMBER OF INDOOR UNITS
NUMBER OF AG150 REQUIRED 1
0 to 50
Allows the group to be interlocked with a heat recovery Lossnay unit
WEB LOGIN
Administrator able to allow specific function access to guest
0
WEB SETPOINT LIMIT
Reduce the setpoint band of each individual unit (e.g. 23ºC to 25ºC)
2
101 to 150
1
3
PAC-YG50ECA FUNCTION
DESCRIPTION
AG150 / PAC-YG50ECA CONNECTION
Ethernet. Ethernet hub and network cables required and not supplied by MEUK
POWER SUPPLY
240VAC 3.2A 250x97x266
Allows each unit within the group to operate in test mode
VENTILATION INTERLOCK
1
(WxDxH)
Displays a 4 digit code and the affected unit address. An error log is held showing the last 64 date stamped alarms
TEST RUN FUNCTION NUMBER OF PAC-YG50ECA REQUIRED
51 to 100
DIMENSIONS - mm
ERROR INDICATION
WEB AUTO CHANGEOVER
Automatically switch heat pump outdoor unit to cooling or heating mode depending on the requirements
WEB INITIAL SETTING
Commission the GB50 from the web pages
WEB REFRIGERANT STATUS CHECK
Activate refrigerant volume checking function on Modular City Multi systems
WEB-INTERLOCK
The GB50 can interlock indoor unit input and output together. For instance, this function could be used for Hotel applications, if card in, set unit to ON, AUTO 21ºC and if card out, set the unit to night set back. This function could also be set in conjunction with PIR sensor in meeting rooms
WEB-LOAD SHEDDING
Activate energy saving mode when energy consumption is too high
EXTERNAL INPUT/OUTPUT
Hardwired connections are available for :
FIRE ALARM
Units will be switched off and the remote controller will be locked under fire alarm condition via a PAC-YG10HA
POWER SUPPLY
Power supply 240VAC 3.2A
COMPATIBILITY DIMENSIONS - mm
Inputs: Level Signal-Batch Start/Stop, Batch Emergency Stop Outputs: Start/Stop Status, Error/Normal Status
City Multi or Mr Slim via PAC-SF81MA or M Series via MAC-399IF (WxDxH)
250x97x266
GB50 Software Options - Pin Code Activation G50 G50 G50 G50
Page 278
- EC - ES - PC - VRC
Energy Charge Energy Saving Capability Peak Cut Control Virtual Remote Controllers
Page 279
PAC-YG50ECA / GB50ADA Controller
GB50ADA Controller
Login
Monitor Air Conditioning - Overview
PAR-21PC Desktop Remote Controller More and more customers are using the AG150/GB50 controllers directly from their computers, so Mitsubishi Electric has launched a new, even simpler alternative which presents the customer with what looks like a standard remote controller interface - on their PC desktop. Called the PAR-21PC, the new application can also be minimised in the Desktop Toolbar, just like other Windows applications, so that the customer can have immediate control with just one click of the mouse.
Access to the web pages is secured using a customised username and password.
The first screen allows you to monitor all the units connected to the AG150/GB50. Each icon displays On/Off, Faults and timer On/Off.
Monitor Air Conditioning - Block view
Remote Controller Settings
M-NET
*NOTE 1
Controls Range
AG150/GB50 Controller Web Screenshots
ETHERNET PAC-SC51KUA
Each area of the building can be displayed with information about On/Off, Setpoint, Mode and Temperature.
Daily, Weekly and Annual Scheduling (AS PIN code)
Click on any icons in the Monitor View page to access the remote controller. Lossnay units can also be controlled. Buttons on the local controllers may be locked (On/Off, Mode, Setpoint, Filter Reset).
Monitor Fault Codes
PAR-21PC Desktop Remote Controller Scheduling may be set from the web pages. A night set back operation is available (Heat, 12ºC). Standard on the AG150/GB50.
Faults with the unit address can be displayed under fault conditions. Email status can also be shown.
Multiple Users (VRC PIN code)
Multiple Users (VRC PIN code)
If the AG150/GB50 is connected to an office LAN, the staff will then be able to access the web pages. With VRC each member of staff will have their own username and password.
Installation costs will be reduced as no wall remote controllers will need to be purchased and installed.
FUNCTION
DESCRIPTION
OPERATION PLATFORM
CPU 1000 Mhz, 512 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2
MAX No. OF INDOOR UNITS
Up to 16 indoor units within a group
ON/OFF
Run and Stop operation for a single group
MODE SELECTION
Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems
TEMPERATURE SETTING
Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C
FAN SPEED SETTING
4 speed: Lo-Mi1-Mi2-Hi, 2 speed: Lo-Hi
AIR FLOW DIRECTION
Air Flow angles:100º-80º-60º-40º and auto swing
CLOCK DISPLAY
Displays the time on the desktop controller
INDOOR RETURN AIR TEMPERATURE
Displays the measured intake temperature from each group
ERROR INDICATION
Displays a 4 digit code and the affected unit address.
TIMER OPERATION
Weekly. Maximum of 3 time sequences with 3 Start/Stop times per day for all groups can be allocated
COMPATABILITY
AG150 and GB50
*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50
Icons available to suit model type installed
Page 280
Page 281
AG150/GB50 Controller Web Screenshots / PAR-21PC Desktop RemaoteController
Technical Information
AG150/GB50 Melcotel Hotel Interface with Key Card System
The new third party equipment interfaces allow the user to monitor and control third party equipment from the AG150/GB50 web pages.
ETHERNET
*NOTE 1
PAC-YG66DCA
The MelcotelTM hotel interface allows a hotel (for example) to have more accurate control over its air conditioning. The MelcotelTM works in conjunction with the key card system installed in each bedroom in many hotels. When the room is occupied, the MelcotelTM will switch ON the unit and reset the air conditioning to predetermined settings (for instance AUTO, 21ºC). When the room is unoccupied, the MelcotelTM will monitor the temperature in the room. If the temperature is too low or too high, the MelcotelTM will restart the unit. The MelcotelTM also offers temperature adjustment facility based on the outside temperature and window open control, that allows the air conditioning to be switched off and controlled centrally when a window is opened. All of these functions provide a higher level of control and therefore more energy saving and a reduction in running costs.
PAC-YG63MCA
M-NET EQUIPMENT 1
EQUIPMENT 2
SENSOR 1
Controls Range
AG150/GB50 Third Party Equipment Interfaces
TM
SENSOR 2
AG150
Technical Information
ETHERNET
Third Party Interfaces
PAC-SC51KUA PAC-YG63MCA
2 x Digital
2 x Analogue
MAX No. OF OUTPUTS
-
2 x Digital
-
MAX No. OF EQUIPMENT
-
POWER SUPPLY
Power supply required
MONITOR
2
-
24VDC
24VDC
From AG150/GB50 web pages or TG2000
Run / Faults
Temperature / Humidity
CONTROL
From AG150/GB50 web pages or TG2000
On/Off
-
SIGNAL
Signal required to monitor and control equipment
Volt free contact
Temperature 4-20mA / 1-5V / 0-10V / Pt100 Humidity 4-20mA / 1-5V / 0-10V
DIMENSIONS - mm
(WxDxH)
-
General Equipment
200x45x120
200x45x120
Temperature / Humidity
USB
Melcotel
Key Window Card Control
Key Window Card Control
Key Window Card Control
TM
Technical Information MELCOTEL
TM
FUNCTION
DESCRIPTION
MAX No. OF INDOOR UNITS
Up to 250 indoor units
TIME TO SWITCH ON
<30s
ON/OFF
Run and Stop operation for a single group
MODE SELECTION
Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems
TEMPERATURE SETTING
Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C
OCCUPIED ROOM SETTING
Configurable. ON, AUTO, 21ºC (Factory setting)
UNOCCUPIED ROOM SETTING
Third party equipment can be monitored and controlled from the web pages.
Temperature and humidity can be monitored.
Trend Logging
Temperature / Humidity Limit
Temperature and humidity can be recorded and displayed. *NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50 NOTE 2: Temperature Sensors and Humidity Sensors not supplied by MEUK
Page 282
Limit (high and low) can be set to trigger alarms via email.
If the temperature is below 16ºC the MelcotelTM restarts the unit to ON, HEAT, 19ºC and stops the unit when the temperature has reached 18ºC (Factory setting)
If the temperature is above 26ºC the MelcotelTM restarts the unit to ON, COOL, 21ºC and stops the unit when the temperature has reached 24ºC (Factory setting)
SEASONS
Up to 4 seasons can be set-up to allow different occupied and unoccupied settings (Setpoint and mode)
OPTIONAL WINDOW CONTACT
If a window sensor is wired to the indoor unit, the MelcotelTM will automatically switch OFF the indoor unit when the window is opened
AUTOMATIC SETPOINT
The MelcotelTM will offset the occupied setpoint depending on the temperature outside (outdoor sensor supplied)
ADJUSTMENT NIGHT TIME OFFSET
During the night the MelcotelTM can offset the setpoint or just switch OFF the unit
INDOOR UNIT CONNECTION
The key card and the window contact is connected back locally to CN32. PAC-SA89TA required for each indoor unit
SOFTWARE
The MelcotelTM Configuration Manager allows the installer to set-up the interface using a USB cable. The MelcotelTM Live Status allows the user to monitor all the different values, for instance, Setpoint, Mode, Key Card IN or OUT, Window Contact etc
FIRE ALARM
Units will be switched off and the remote controller will be locked under fire alarm condition
POWER SUPPLY
240 VAC 2A
COMPATIBILITY
GB50 and AG150, but City Multi only
DIMENSIONS - mm (WxDxH)
300x70x350
DEMONSTRATION
Visit www.melcotel.co.uk for more details Page 283
TM
PAC-YG66DCA
-
Melcotel Hotel Interface with Key Card System
DESCRIPTION
MAX No. OF INPUTS
AG150/GB50 Third Party Equipment Interfaces /
FUNCTION
The MelcotelTM controller allows a hotel (for example) to have more accurate control over its air conditioning. When the unit has been switched ON by a user, the room is deemed as occupied and the MelcotelTM resets the air conditioning to predetermined settings (for instance AUTO, 21ºC). After a preset time, the MelcotelTM will switch OFF the unit automatically. When the room is unoccupied, the MelcotelTM will monitor the temperature in the room. If the temperature is too low or too high, the MelcotelTM will restart the unit. The MelcotelTM also offers temperature adjustment facility based on the outside temperature and window open control, that allows the air conditioning to be switched off and controlled centrally when a window is opened. All of these functions provide a higher level of control and therefore more energy saving and a reduction in running costs.
AG150/GB50 Melcotel Hotel Interface with Machine 2 Machine TM
The MelcotelTM hotel interface can be connected to the Mini M2M Machine 2 Machine interface to allow remote monitoring of the air conditioning, but also the window contact and the key card system.
Mini M2M-A/16
M-NET
MEUK M2M SERVER
GPRS
Melcotel
TM
Melcotel
TM
Controls Range
AG150/GB50 Melcotel Hotel Interface without Key Card System TM
AG150
ETHERNET PAC-SC51KUA
USB
Mini M2M-A/16 Window Control
Window Control
Window Control
Melcotel
TM
Technical Information TM
MELCOTEL
TM
FUNCTION
DESCRIPTION
MAX No. OF INDOOR UNITS
Up to 250 indoor units
FUNCTION
TIME TO SWITCH ON
<30s
MAX No. OF INDOOR UNITS: UP TO 250
ON/OFF
Run and Stop operation for a single group
ON/OFF
MODE SELECTION
Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems
TEMPERATURE SETTING
Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C
OCCUPIED ROOM SETTING
Configurable. ON, AUTO, 21ºC (Factory setting)
MODE ROOM TEMPERATURE SET TEMPERATURE SET BACK KEY CARD
UNOCCUPIED ROOM SETTING
WINDOW SENSOR EXTERNAL TEMPERATURE
If the temperature is above 26ºC the MelcotelTM restarts the unit to ON, COOL, 21ºC and stops the unit when the temperature has reached 24ºC (Factory setting)
SEASONS
Up to 4 seasons can be set-up to allow different occupied and unoccupied settings (Setpoint and mode)
OPTIONAL WINDOW CONTACT
If a window sensor is wired to the indoor unit, the MelcotelTM will automatically switch OFF the indoor unit when the window is opened
AUTOMATIC SETPOINT
The MelcotelTM will offset the occupied setpoint depending on the temperature outside (outdoor sensor supplied)
AUTO SWITCH OFF
6 Off times can be preset to regularly switch OFF the indoor unit
ADJUSTMENT NIGHT TIME OFFSET
During the night the MelcotelTM can offset the setpoint or just switch OFF the unit
INDOOR UNIT CONNECTION
The window contact is connected back locally to CN32. PAC-SA89TA required for each indoor unit
SOFTWARE
The MelcotelTM Configuration Manager allows the installer to set-up the interface using a USB cable. The MelcotelTM Live Status allows the user to monitor all the different values, for instance, Setpoint, Mode, Window Contact etc
FIRE ALARM
Units will be switched off and the remote controller will be locked under fire alarm condition
POWER SUPPLY
240 VAC 2A
COMPATIBILITY
GB50 and AG150, but City Multi only
DIMENSIONS - mm (WxDxH)
300x70x350
DEMONSTRATION
Visit www.melcotel.co.uk for more details
Page 284
TM
If the temperature is below 16ºC the MelcotelTM restarts the unit to ON, HEAT, 19ºC and stops the unit when the temperature has reached 18ºC (Factory setting)
DEMONSTRATION
Visit www.melcotel.co.uk for more details Page 285
TM
Melcotel Hotel Interface without Key Card System / Melcotel Hotel Interface with M2M
MELCOTEL
Technical Information
TG2000 Software with Energy Monitoring
PC Based Software Package
PC Based Software Package
The TG2000 centralised PC based graphical software package allows the operator to control and monitor up to a maximum of 2000 indoor units. This software has been designed to connect directly to an air conditioning system via the AG150/GB50 controller, allowing the operator the required functionality to control and monitor the complete air conditioning system from a central location.
The TG2000 centralised PC based graphical software package allows the operator to control and monitor up to a maximum of 2000 indoor units. This software has been designed to connect directly to an air conditioning system via the AG150/GB50 controller, allowing the operator all the required functionality to control and monitor the complete air conditioning system from a central location. In addition to providing a centralised control facility, the TG2000 allows complete energy consumption data to be logged with user definable billing groups and electrical tariffs for billing purposes.
M-NET
M-NET
*NOTE 1 *NOTE 1
Controls Range
TG2000 Software
ETHERNET
ETHERNET
PAC-YG60MCA
PAC-SC51KUA PAC-SC51KUA
METER 1
METER 2
METER 3
METER 4
Technical Information
Technical Information TG2000 PC Based software that works in conjunction with AG150/GB50 Controller
FUNCTION
DESCRIPTION
OPERATING PLATFORM
CPU 1000 Mhz, 512 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2 or Windows Vista or Windows 7
MAX No. OF INDOOR UNITS
2000 Indoor units, 50 indoor units per AG150/GB50
OPERATIONAL SECTIONS
The software package is split into two distinctive areas, System and Controls setting. System Setting: Password protected, System Configuration and group/block organisation, printer setting. Controls Setting: Normal Operation, monitoring and control functions as described below. The software allows individual indoor units to be allocated to logical groups, represented within user definable graphics screens, allocated during the system configuration
FUNCTION
DESCRIPTION
OPERATING PLATFORM
CPU 1000 Mhz, 512 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2 or Windows Vista or Windows 7
ON/OFF
Indicates the On/Off status of each group within the selected graphical screen or entire building
MAX No. OF INDOOR UNITS
2000 Indoor units, 50 indoor units per AG150/GB50
OPERATION MODE
Indicates the operational mode (Cool, Heat, Fan, Dry, Auto) for each group on the selected graphical screen
OPERATIONAL SECTIONS
The software package is split into two distinctive areas, System and Controls setting. System Setting: Password protected, System Configuration and group/block organisation, printer setting. Controls Setting: Normal Operation, monitoring and control functions as described below. The software allows individual indoor units to be allocated to logical groups, represented within user definable graphics screens, allocated during the system configuration
SET TEMPERATURE
Displays the set temperature for each group on the selected graphical screen. Also able to limit the set point range in both heating and cooling mode
AIR SPEED
Displays the current fan speed setting for each group on the selected graphical screen
ON/OFF
Indicates the On/Off status of each group within the selected graphical screen or entire building Indicates the operational mode (Cool, Heat, Fan, Dry, Auto) for each group on the selected graphical screen
REMOTE CONTROLLER PROHIBIT/PERMIT
Displays the current prohibit/permit status for each groups remote controller on the selected graphical screen
OPERATION MODE SET TEMPERATURE
Displays the set temperature for each group on the selected graphical screen. Also able to limit the set point range in both heating and cooling mode
ABNORMALITY (FAULT) MONITORING
AIR SPEED
Displays the current fan speed setting for each group on the selected graphical screen
Individual indoor unit fault monitoring is recorded within the fault log for both viewing and printing. Fault monitoring can also be viewed via the fault log for all units associated with a particular graphical screen or the entire building. Faults can also be tracked and printed using date of failure, date of recovery and error code
REMOTE CONTROLLER PROHIBIT/PERMIT
Displays the current prohibit/permit status for each groups remote controller on the selected graphical screen
ROOM TEMPERATURE MONITORING
Displays the return air temperature of the master indoor unit within a group
SCHEDULED ON/OFF
On/Off schedules can be set for each group, each graphical screen or the entire building
ABNORMALITY (FAULT) MONITORING
Individual indoor unit fault monitoring is recorded within the fault log for both viewing and printing. Fault monitoring can also be viewed via the fault log for all units associated with a particular graphical screen or the entire building. Faults can also be tracked and printed using date of failure, date of recovery and error code
ENERGY CHARGING
Able to create or email bills for individual indoor units, groups of indoor units or a complete system (Optional) via the PAC-YG60MCA
WEB REFRIGERANT STATUS CHECK
Activate refrigerant volume checking function on Modular City Multi systems
ENERGY CHARGING
Able to create bills for individual indoor units, groups of indoor units or a complete system (Optional) via the PAC-YG60MCA
ROOM TEMPERATURE MONITORING
Displays the return air temperature of the master indoor unit within a group
SCHEDULED ON/OFF
On/Off schedules can be set for each group, each graphical screen or the entire building
ENERGY SAVE CONTROL
ENERGY SAVE CONTROL
Individual indoor unit, group of indoor units or a complete system can be controlled. There are various energy saving options available (Optional)
Individual indoor unit, group of indoor units or a complete system can be controlled. There are various energy saving options available (Optional)
LOAD SHEDDING
Activate energy saving mode when energy consumption is too high
TREND LOGGING
Able to log: Return air temperature, setpoint, mode, On/Off, power consumption by group or by indoor unit, watt-hour meter and then email to customer
TREND LOGGING
Able to log: Return air temperature, setpoint, mode, On/Off, power consumption by group or by indoor unit, watt-hour meter and then email to customer
GRAPHICAL SCREENS
The complete system configurations can be allocated between multiple screens. Each screen can display a bitmap image representing the area of the building or floor where the units or groups are physically located
GRAPHICAL SCREENS
The complete system configurations can be allocated between multiple screens. Each screen can display a bitmap image representing the area of the building or floor where the units or groups are physically located
The following information may be sent regularly and automatically via email: energy monitoring data, energy saving data, trend logging data (temperatures etc) and fault code history
The following information may be sent regularly and automatically via email: energy monitoring data, energy saving data, trend logging data (temperatures etc) and fault code history
*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50
Page 286
*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50 NOTE 2: Energy Meters not supplied by MEUK
Page 287
TG2000 Software / TG2000 Software with Energy Monitoring
TG2000 Software with Energy Monitoring
Energy monitoring is key to comply with Part L2 regulations. Some time ago we introduced the PAC-YG60MCA MNET interfaces, which can be connected anywhere on our MNET network and will monitor up to 4 pulse meters. These interfaces make installation easier, more cost effective and are shown in option A below. This year, all of our City Multi outdoor units now have a direct connection to pulse meters. This means that the pulse meter can be connected to the outdoor unit directly, negating the need for interfaces, panels and a power supply and therefore reducing the installation cost significantly. This is shown in option B below.
Option A:
TG2000 Software with Third Party Equipment PC Based Software Package The TG2000 centralised PC based graphical software package allows the operator to control and monitor up to a maximum of 2000 indoor units. This software has been designed to connect directly to an air conditioning system via the AG150/GB50 controller, allowing the operator all the required functionality to control and monitor the complete air conditioning system from a central location. In addition to providing a centralised control facility, the TG2000 allows you to monitor and control third party equipment.
M-NET
M-NET *NOTE 1
Controls Range
Energy Monitoring
*NOTE 1
ETHERNET PAC-YG60MCA
ETHERNET
PAC-SC51KUA
PAC-SC51KUA PAC-YG66DCA METER 1
METER 2
METER 3
PAC-YG63MCA
METER 4
Option B:
EQUIPMENT 1
EQUIPMENT 2
SENSOR 1
SENSOR 2
Technical Information M-NET
*NOTE 1
DESCRIPTION
OPERATING PLATFORM
CPU 1000 Mhz, 512 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2 or Windows Vista or Windows 7
MAX No. OF INDOOR UNITS
2000 Indoor units, 50 indoor units per AG150/GB50
OPERATIONAL SECTIONS
The software package is split into two distinctive areas, System and Controls setting. System Setting: Password protected, System Configuration and group/block organisation, printer setting. Controls Setting: Normal Operation, monitoring and control functions as described below. The software allows individual indoor units to be allocated to logical groups, represented within user definable graphics screens, allocated during the system configuration
ON/OFF
Indicates the On/Off status of each group within the selected graphical screen or entire building
OPERATION MODE
Indicates the operational mode (Cool, Heat, Fan, Dry, Auto) for each group on the selected graphical screen
SET TEMPERATURE
Displays the set temperature for each group on the selected graphical screen. Also able to limit the set point range in both heating and cooling mode
AIR SPEED
Displays the current fan speed setting for each group on the selected graphical screen
REMOTE CONTROLLER PROHIBIT/PERMIT
Displays the current prohibit/permit status for each groups remote controller on the selected graphical screen
ABNORMALITY (FAULT) MONITORING
Individual indoor unit fault monitoring is recorded within the fault log for both viewing and printing. Fault monitoring can also be viewed via the fault log for all units associated with a particular graphical screen or the entire building. Faults can also be tracked and printed using date of failure, date of recovery and error code
ROOM TEMPERATURE MONITORING
Displays the return air temperature of the master indoor unit within a group
SCHEDULED ON/OFF
On/Off schedules can be set for each group, each graphical screen or the entire building
ENERGY SAVE CONTROL
Individual indoor unit, group of indoor units or a complete system can be controlled. There are various energy saving options available (Optional)
TREND LOGGING
Able to log: Return air temperature, setpoint, mode, On/Off, power consumption by group or by indoor unit, watt-hour meter and then email to customer
GRAPHICAL SCREENS
The complete system configurations can be allocated between multiple screens. Each screen can display a bitmap image representing the area of the building or floor where the units or groups are physically located
ETHERNET PAC-YG60MCA PAC-SC51KUA METER 1
Technical Information
Pulse Meter Direct Connection to City Multi Outdoor Unit FUNCTION
PRODUCT REQUIRED
DESCRIPTION
OUTDOOR kW
AG150, AG150-Basic Energy Meters
The energy consumption of the outdoor can be monitored using the AG150 Webpages
INDOOR kW
AG150, AG150-Basic AG150-Energy, TG2000 Energy Meters
The energy consumption of the indoor unit can be estimated using the TG2000 software package. The software package will also allow the end user to generate bills with multiple tariffs
Product Required PAC-SA89TA
Cable required to connect the pulse meter to the outdoor unit
PAC-CN32WHMC-UK
Jumper to activate the outdoor pulse input
THIRD PARTY EQUIPMENT MONITOR
Monitor general equipment Run and Faults via the PAC-YG66DCA interface and Temperature and Humidity via the PAC-YG63MCA
THIRD PARTY EQUIPMENT CONTROL
Control general equipment On/Off via the PAC-YG66DCA
The following information may be sent regularly and automatically via email: energy monitoring data, energy saving data, trend logging data (temperatures etc) and fault code history
*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50 NOTE 2: Temperature and Humidity Sensors not supplied by MEUK
Page 288
Page 289
Energy Monitoring / TG2000 Software with Third Party Equipment
TG2000 Software with Third Party Equipment FUNCTION
PC Based Software Package used to monitor and control multiple sites
TG2000
Controls Range
TG2000 WAN (Wide Area Network) Software
Screenshots
Display Whole
Display Block
The 2000 indoor units status may be shown on one screen.
Block may be set for each area. Settings may be changed by one click of the mouse for each area.
Display Floor
Remote Controller Settings
AutoCAD drawing may be imported to TG2000 to display floor screens.
Click on any icons in the floor view to access the remote controller settings. Buttons on the local controllers may be locked (On/Off, Mode, Setpoint, Filter reset).
Daily, Weekly and Annual Scheduling
Monitor Fault Codes
Scheduling may be set from the TG2000. A night set back operation is available (HEAT, 12ยบC).
Faults with the unit address can be displayed under fault conditions.
Energy Monitoring (AG150 Energy PIN code)
Energy Saving (AG150 Energy PIN code)
TG2000 in conjunction with energy meters can monitor the energy consumption for each outdoor unit, indoor unit or area. The indoor unit run hours can also be displayed.
TG2000 offers different energy saving options including load shedding.
The TG2000 WAN centralised PC based graphical software package allows the operator to control and monitor up to a maximum of 1000 sites. Utilising the companies Wide Area Network, the complete (geographically distributed) air conditioning asset base can be controlled and monitored from a centralised location.
PAC-YG66DCA
WAN
PAC-YG63MCA
SITE 1 (i.e. MANCHESTER) *NOTE 1
EQUIPMENT 1
EQUIPMENT 2
SENSOR 1
PAC-YG66DCA
SENSOR 2
PAC-YG63MCA
SITE 999 (i.e. BIRMINGHAM) *NOTE 1
EQUIPMENT 1
EQUIPMENT 2
SENSOR 1
SENSOR 2
Technical Information
DESCRIPTION
OPERATING PLATFORM
CPU 1000 Mhz, 512 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2 or Windows Vista or Windows 7
MAX No. OF SITES
1000
MAX No. OF INDOOR UNITS PER SITE
2000 Indoor units, 50 indoor units per AG150/GB50 (per site)
OPERATIONAL SECTIONS
The software package is split into two distinctive areas, System and Controls setting. System Setting: Password protected, System Configuration and group/block organisation, printer setting. Controls Setting: Normal Operation, monitoring and control functions as described below. The software allows individual indoor units to be allocated to logical groups, represented within user definable graphics screens, allocated during the system configuration
ON/OFF
Indicates the On/Off status of each group within the selected graphical screen or entire building
OPERATION MODE
Indicates the operational mode (Cool, Heat, Fan, Dry, Auto) for each group on the selected graphical screen
SET TEMPERATURE
Displays the set temperature for each group on the selected graphical screen. Also able to limit the set point range in both heating and cooling mode
AIR SPEED
Displays the current fan speed setting for each group on the selected graphical screen
REMOTE CONTROLLER PROHIBIT/PERMIT
Displays the current prohibit/permit status for each groups remote controller on the selected graphical screen
ABNORMALITY (FAULT) MONITORING
Individual indoor unit fault monitoring is recorded within the fault log for both viewing and printing. Fault monitoring can also be viewed via the fault log for all units associated with a particular graphical screen or the entire building. Faults can also be tracked and printed using date of failure, date of recovery and error code
ROOM TEMPERATURE MONITORING
Displays the return air temperature of the master indoor unit within a group
SCHEDULED ON/OFF
On/Off schedules can be set for each group, each graphical screen or the entire building
GRAPHICAL SCREENS
The complete system configurations can be allocated between multiple screens. Each screen can display a bitmap image representing the area of the building or floor where the units or groups are physically located
THIRD PARTY EQUIPMENT MONITORING
Monitor general equipment Run and Faults via the PAC-YG66DCA interface and Temperature and Humidity via the PAC-YG63MCA
THIRD PARTY EQUIPMENT CONTROL
Control general equipment On/Off via the PAC-YG66DCA
The following information may be sent regularly and automatically via email: energy monitoring data, energy saving data, trend logging data (temperatures etc) and fault code history
TG2000 WAN Software / TG2000 Screenshots
TG2000WAN (Wide Area Network) Software FUNCTION
Icons available to suit model type installed
*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50 NOTE 2: The TG2000 WAN cannot be utilised if the following site functions are required: energy charging, energy saving and trend logging. NOTE 3: Temperature and Humidity Sensors not supplied by MEUK
Page 290
Page 291
BEMS BACnet Interface
Controls Range
BEMS BACnet Interface ®
®
BAC-HD150
Procon BAC-IP/50 TM
®
To further enhance our complete open system network offering, we offer a BACnet interface solution. Utilising the ASHRAE BACnet standard, complete control and monitoring integration can be achieved with up to 50 air conditioning units. ®
®
To further enhance our complete open system network offering, we offer a BACnet interface solution. Utilising the ASHRAE BACnet standard, complete control and monitoring integration can be achieved with up to 50 air conditioning units. ®
BAC-HD150
M-NET
*NOTE 1
ETHERNET PAC-SC51KUA
TCP / IP
TCP / IP
Technical Information
BAC-IP/50
Technical Information
BACnet INTERFACE ®
BACnet INTERFACE
FUNCTION
BAC-HD150
COMPATIBLE WITH
MAX No. OF INDOOR UNITS
50
Andover Controls
CENTRALISED CONTROLLER REQUIRED
No
York BMS
POWER SUPPLY
240VAC 3.2A
COMPATIBILITY
City Multi Mr Slim via PAC-SF81MA M Series via MAC-399IF
BEMS CONNECTION
Ethernet
DIMENSIONS - mm (WxDxH)
250x97x266
®
FUNCTION
BAC-IP/50
COMPATIBLE WITH
MAX No. OF INDOOR UNITS
50
Andover Controls
CENTRALISED CONTROLLER REQUIRED
Yes (AG150 or GB50)
POWER SUPPLY
24VAC 0.5A
COMPATIBILITY
City Multi Mr Slim via PAC-SF81MA M Series via MAC-399IF
York BMS
Siemens
BEMS CONNECTION
Ethernet via HUB
DIMENSIONS - mm (WxDxH)
144x34x104
Priva Building Intelligence
Delta Controls
Delta Controls
®
®
NETWORK VARIABLE
POINT TYPE
NOTES
FUNCTION
NETWORK VARIABLE
POINT TYPE
NOTES
On/Off
Digital Input
Run/Stop
On/Off
Digital Input
Run/Stop
Mode Operation
Analogue Input
Cool / Dry / Heat / Auto / Fan
Mode Operation
Analogue Input
Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment
Analogue Input
Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Setpoint Adjustment
Analogue Input
Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Fan Speed Control
Analogue Input
Lo-Mi1-Mi2-Hi
Fan Speed Control
Analogue Input
Lo-Mi1-Mi2-Hi
Permit / Prohibit
Digital Input
On/Off, Mode, Setpoint
Permit / Prohibit
Digital Input
On/Off, Mode, Setpoint
Airflow Direction
Analogue Input
Horizontal - 60,80,100º swing
Airflow Direction
Analogue Input
Horizontal - 60,80,100º swing
Filter Sign
Digital Input
Normal/Reset
Filter Sign
Digital Input
Normal/Reset
Run/Stop
On/Off
Digital Output
Run/Stop
Analogue Output
Cool / Dry / Heat / Auto / Fan
BEMS BACnet® Interfaces
Control
Control
Monitor
Monitor On/Off
Digital Output
Mode Operation
Analogue Output
Cool / Dry / Heat / Auto / Fan
Mode Operation
Setpoint Adjustment
Analogue Output
Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Setpoint Adjustment
Analogue Output
Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Fan Speed Control
Analogue Output
Lo-Mi1-Mi2-Hi
Fan Speed Control
Analogue Output
Lo-Mi1-Mi2-Hi
Permit / Prohibit
Digital Output
On/Off, Mode, Setpoint
Permit / Prohibit
Digital Output
On/Off, Mode, Setpoint
Airflow Direction
Analogue Output
Horizontal - 60,80,100º swing
Airflow Direction
Analogue Output
Horizontal - 60,80,100º swing
Fault Code
Analogue Output
4 Character code - Indicates all unit alarms
Fault Code
Analogue Output
4 Character code - Indicates all unit alarms
Filter Sign
Digital Output
-
Filter Sign
Digital Output
-
Room Temperature
Analogue Output
-
Room Temperature
Analogue Output
-
*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50
Page 292
Priva Building Intelligence
BACnet INTERFACE
BACnet INTERFACE FUNCTION
Siemens
*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50
Page 293
®
Procon BAC-A/50
BEMS LonWorks Interface ®
LMAP
TM
®
A new BACnet Interface has been specially developed for the Mr Slim systems. The BAC-A/50 can control up to 50 individual systems.
The Mitsubishi Electric LMAP continues to strengthen the ability of our products to interface with other third party building control systems using the globally recognised and accepted open network protocol Echelon LonWorks®. LonWorks® was introduced into the building services industry a number of years ago with the aim of establishing itself as the defacto communications standard. Many hundreds of products now exist that utilise the LonWorks® protocol from complete systems like BEMS, lighting, power monitoring and security down to simple sensors and relay switches. To ensure that our products can connect directly and easily with other LonWorks® products, the L-MAP02 was designed utilising Echelon MIPS technology and was the first to provide data in the LonWorks® SNVT (Standard Network Variable Type) format.
PAC-SK82SI
Controls Range
BEMS BACnet Mr Slim Interface
M-NET
TCP / IP
BAC-A/50
FTT-10 LMAP
Technical Information
Technical Information ®
LMAP LonWorks INTERFACE
BACnet MR SLIM INTERFACE ®
FUNCTION
BAC-A/50
COMPATIBLE WITH
FUNCTION
LMAP
COMPATIBLE WITH
MAX No. OF INDOOR UNITS
50
Andover Controls
MAX No. OF INDOOR UNITS
50
Honeywell
CENTRALISED CONTROLLER REQUIRED
No
York BMS
CENTRALISED CONTROLLER REQUIRED
No
POWER SUPPLY
240VAC 0.5A
Siemens
POWER SUPPLY
240VAC 0.5A
COMPATIBILITY
Mr Slim via PAC-SK82SI
Priva Building Intelligence
COMPATIBILITY
BEMS CONNECTION
Ethernet
City Multi Mr Slim via PAC-SF81MA M Series via MAC-399IF
DIMENSIONS - mm (WxDxH)
270x75x210
Delta Controls
BEMS CONNECTION
LonWorks FTT-10
DIMENSIONS - mm (WxDxH)
340x60x360
Johnson Controls
POINT TYPE
®
LMAP LonWorks INTERFACE NOTES
Control
NETWORK VARIABLE
POINT TYPE
NOTES
Control On/Off
Digital Input
Run/Stop
On/Off
Digital Input
Run/Stop
Mode Operation
Analogue Input
Cool / Dry / Heat / Auto / Fan
Mode Operation
Analogue Input
Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment
Analogue Input
Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Setpoint Adjustment
Analogue Input
Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Fan Speed Control
Analogue Input
Lo-Mi1-Mi2-Hi
Fan Speed Control
Analogue Input
Lo-Mi1-Mi2-Hi
Permit / Prohibit
Digital Input
On/Off, Mode, Setpoint
Permit / Prohibit
Digital Input
On/Off, Mode, Setpoint (only available when using PAC-YT51CRA or PAR-21MAA)
Filter Sign
Digital Input
Normal/Reset
Filter Sign
Digital Input
Normal/Reset
On/Off
Digital Output
Run/Stop
On/Off
Digital Output
Run/Stop
Mode Operation
Analogue Output
Cool / Dry / Heat / Auto / Fan
Mode Operation
Analogue Output
Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment
Analogue Output
Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Setpoint Adjustment
Analogue Output
Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Fan Speed Control
Analogue Output
Lo-Mi1-Mi2-Hi
Fan Speed Control
Analogue Output
Lo-Mi1-Mi2-Hi
Permit / Prohibit
Digital Output
On/Off, Mode, Setpoint
Permit / Prohibit
Digital Output
On/Off, Mode, Setpoint (only available when using PAC-YT51CRA or PAR-21MAA)
Fault Code
Analogue Output
4 Character code - Indicates all unit alarms
Fault Code
Analogue Output
4 Character code - Indicates all unit alarms
Filter Sign
Digital Output
-
Filter Sign
Digital Output
-
Room Temperature
Analogue Output
-
Room Temperature
Analogue Output
-
Monitor
Monitor
*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50
Page 294
FUNCTION
*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50
Page 295
BEMS BACnet® Mr Slim Interface / BEMS LonWorks® Interface
®
NETWORK VARIABLE
(LTX51/LTX21 via VCI)
Smart Controls
BACnet MR SLIM INTERFACE FUNCTION
Realtime Control Systems
BEMS Modbus Mr Slim Interface
Procon MOD-IP/50
Procon A32M
To further complement the existing control and interface product ranges being offered by Mitsubishi Electric to support their air conditioning systems, the Modbus range has been developed to accommodate the typical end-user needs as experienced within the UK market.
To further complement the existing control and interface product ranges being offered by Mitsubishi Electric to support their air conditioning systems, the Modbus range has been developed to accommodate the typical end-user needs as experienced within the UK market.
TM
TM
M-NET
PAC-SK82SI
*NOTE 1
Controls Range
BEMS Modbus Interface
ETHERNET PAC-SC51KUA
Modbus RS232 / 485
Modbus
A32M
RS232 / 485 or TCP / IP
Technical Information Technical Information
MODBUS INTERFACE FUNCTION
MOD-IP/50
COMPATIBLE WITH
MAX No. OF INDOOR UNITS
50
Trend via Synapsys SXNC200
CENTRALISED CONTROLLER REQUIRED
Yes (AG150 or GB50)
POWER SUPPLY
240VAC 0.5A
COMPATIBILITY
City Multi Mr Slim via PAC-SF81MA M Series via MAC-399IF
MODBUS MR SLIM INTERFACE FUNCTION
A32M
COMPATIBLE WITH
MAX No. OF INDOOR UNITS
32
Trend via Synapsys SXNC200
CENTRALISED CONTROLLER REQUIRED
No
POWER SUPPLY
240VAC 0.5A
Invensys
North BT
COMPATIBILITY
Mr Slim via PAC-SK82SI
Interactive Homes
Cylon Satchwell Crestron (Home automation) Invensys Interactive Homes
Cylon Satchwell Crestron (Home automation)
North BT
BEMS CONNECTION
Serial RS232, RS485 or TCP / IP
Andover
BEMS CONNECTION
Serial RS232 or 485
Andover
DIMENSIONS - mm (WxDxH)
144x34x104
Siemens
DIMENSIONS - mm (WxDxH)
270x75x210
Siemens
NOTES
MODBUS MR SLIM INTERFACE - OPERATIONAL INFORMATION
FUNCTION
NETWORK VARIABLE
POINT TYPE
Control On/Off
Digital Input
Run/Stop
Mode Operation
Analogue Input
Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment
Analogue Input
Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Fan Speed Control
Analogue Input
Lo-Mi1-Mi2-Hi
Permit / Prohibit
Digital Input
On/Off, Mode, Setpoint
Airflow Direction
Analogue Input
Horizontal - 60,80,100º swing
Filter Sign
Digital Input
Normal/Reset
Monitor
NETWORK VARIABLE
POINT TYPE
NOTES
Control On/Off
Digital Input
Run/Stop
Mode Operation
Analogue Input
Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment
Analogue Input
Cooling 19-30ºC Heating 17-28ºC Auto 19-28ºC
Fan Speed Control
Analogue Input
Lo-Mi1-Mi2-Hi
Monitor
On/Off
Digital Output
Run/Stop
Mode Operation
Analogue Output
Cool / Dry / Heat / Auto / Fan
On/Off
Digital Output
Run/Stop
Setpoint Adjustment
Analogue Output
Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Mode Operation
Analogue Output
Cool / Dry / Heat / Auto / Fan
Fan Speed Control
Analogue Output
Lo-Mi1-Mi2-Hi
Setpoint Adjustment
Analogue Output
Cooling 19-30ºC
Permit / Prohibit
Digital Output
On/Off, Mode, Setpoint
Airflow Direction
Analogue Output
Horizontal - 60,80,100º swing
Fault Code
Analogue Output
4 Character code - Indicates all unit alarms
Fan Speed Control
Analogue Output
Lo-Mi1-Mi2-Hi
Filter Sign
Digital Output
-
Fault Code
Analogue Output
4 Character code - Indicates all unit alarms
Room Temperature
Analogue Output
-
Room Temperature
Analogue Output
-
*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50
Page 296
FUNCTION
BEMS Modbus Interface / BEMS Modbus Mr Slim Interface
MODBUS INTERFACE - OPERATIONAL INFORMATION
Heating 17-28ºC Auto 19-28ºC
NOTE: Not available on SEZ / SLZ
Page 297
Procon A1M
Procon KNX-EIB-IP-15/100
To further complement the existing control and interface product ranges being offered by Mitsubishi Electric to support their air conditioning systems, the Modbus range has been developed to accommodate the typical end-user needs as experienced within the UK market.
To further complement the existing control and interface product ranges being offered by Mitsubishi Electric to support their air conditioning systems, the KNX-EIB range has been developed to accommodate the typical end-user needs as experienced within the UK market.
TM
TM
M-NET
*NOTE 1
ETHERNET
Controls Range
BEMS KNX-EIB Interfaces
BEMS Modbus Splits Interface
PAC-SC51KUA
A1M
KNX-EIB
Modbus RS485 KNX-EIB-IP-15 KNX-EIB-IP-100
Technical Information
MODBUS SPLITS INTERFACE FUNCTION
A1M
COMPATIBLE WITH
MAX No. OF INDOOR UNITS
1
CENTRALISED CONTROLLER REQUIRED
No
Trend via Synapsys SXNC200 Cylon Satchwell Crestron (Home automation) Invensys Interactive Homes North BT Andover Siemens
COMPATIBILITY
M Series Mr Slim
BEMS CONNECTION
Serial RS485
DIMENSIONS - mm (WxDxH)
72x27x50
KNX-EIB CITY MULTI INTERFACES FUNCTION
KNX-EIB-IP-15
KNX-EIB-IP-100
COMPATIBLE WITH ABB
MAX No. OF INDOOR UNITS
15
100
CENTRALISED CONTROLLER REQUIRED
Yes (AG150 or GB50)
Yes (AG150 or GB50)
POWER SUPPLY
9 to 30VDC or 24VAC 0.5A
9 to 30VDC or 24VAC 0.5A
COMPATIBILITY
City Multi Mr Slim via PAC-SF81MA M Series via MAC-399IF
City Multi Mr Slim via PAC-SF81MA M Series via MAC-399IF
BEMS CONNECTION
Ethernet via HUB
Ethernet via HUB
DIMENSIONS - mm (WxDxH)
107x58x105
107x58x105
Intelligent Buildings
Nova Controls Ltd
Siemens
MODBUS SPLITS INTERFACE - OPERATIONAL INFORMATION
KNX-EIB CITY MULTI INTERFACE UNITS - OPERATIONAL INFORMATION
FUNCTION
FUNCTION
NETWORK VARIABLE
POINT TYPE
NOTES
NETWORK VARIABLE
POINT TYPE
BEMS Modbus Splits Interface / BEMS KNX-EIB Interfaces
Technical Information
NOTES
Control
Control On/Off
Digital Input
Run/Stop
On/Off
Digital Input
Run/Stop
Mode Operation
Analogue Input
Cool / Dry / Heat / Auto / Fan
Mode Operation
Analogue Input
Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment
Analogue Input
Cooling 19-30ºC
Setpoint Adjustment
Analogue Input
Cooling 19-30ºC Heating 17-28ºC
Heating 17-28ºC
Auto 19-28ºC
Auto 19-28ºC Fan Speed Control
Analogue Input
Lo-Mi1-Mi2-Hi
Fan Speed Control
Analogue Input
Lo-Mi1-Mi2-Hi
Monitor
Monitor On/Off
Digital Output
Run/Stop
On/Off
Digital Output
Run/Stop
Mode Operation
Analogue Output
Cool / Dry / Heat / Auto / Fan
Mode Operation
Analogue Output
Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment
Analogue Output
Cooling 19-30ºC
Setpoint Adjustment
Analogue Output
Cooling 19-30ºC Heating 17-28ºC
Heating 17-28ºC
Auto 19-28ºC
Auto 19-28ºC Fan Speed Control
Analogue Output
Lo-Mi1-Mi2-Hi
Fan Speed Control
Analogue Output
Lo-Mi1-Mi2-Hi
Fault Code
Analogue Output
4 Character code - Indicates all unit alarms
Fault Code
Analogue Output
4 Character code - Indicates all unit alarms
Room Temperature
Analogue Output
-
Room Temperature
Analogue Output
-
*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50
Page 298
Page 299
BEMS Trend Interface
Procon KNX-EIB-A-1
Trend IQ3 Excite
To further complement the existing control and interface product ranges being offered by Mitsubishi Electric to support their air conditioning systems, the KNX-EIB range has been developed to accommodate the typical end-user needs as experienced within the UK market.
Mitsubishi Electric and Synapsys Solutions have been working together for the last six years to offer very competitive solutions for Trend users. The IQ3 Excite Interface has been modified by Synapsys Solutions to work directly in conjunction with the AG150 and GB50 centralised controllers. This allows Trend users to easily integrate Trend systems with Mitsubishi Electric air conditioning.
TM
Controls Range
BEMS KNX-EIB Splits Interface
M-NET
*NOTE 1
ETHERNET
KNX-EIB-A-1
PAC-SC51KUA
KNX-EIB
Trend IQ3 Excite (must be supplied by Synapsys)
Technical Information TREND INTERFACE
Technical Information KNX-EIB SPLITS INTERFACE FUNCTION
KNX-EIB-A-1
COMPATIBLE WITH
MAX No. OF INDOOR UNITS
1
ABB
CENTRALISED CONTROLLER REQUIRED
No
COMPATIBILITY
FUNCTION
IQ3 EXCITE
COMPATIBLE WITH
MAX No. OF INDOOR UNITS
50
Trend only
CENTRALISED CONTROLLER REQUIRED
Yes (AG150 or GB50)
POWER SUPPLY
240VAC
COMPATIBILITY
City Multi Mr Slim via PAC-SF81MA M Series via MAC-399IF
BEMS CONNECTION
Ethernet via HUB
DIMENSIONS - mm (WxDxH)
263x42x130
Intelligent Buildings
M Series Mr Slim
Nova Controls Ltd
BEMS CONNECTION
KNX (TP-1) EIB
DIMENSIONS - mm (WxDxH)
60x25x48
Siemens
IMPORTANT NOTE: The IQ3 Excite Interface can only be supported by Synapsys Solutions (Tel: 01273 831831)
KNX-EIB SPLITS INTERFACE - OPERATIONAL INFORMATION FUNCTION
NETWORK VARIABLE
POINT TYPE
NOTES
NETWORK VARIABLE
POINT TYPE
NOTES
Control
Control
On/Off
Switch
Run/Stop
Mode Operation
Knob
Cool / Dry / Heat / Auto / Fan
On/Off
Digital Input
Run/Stop
Setpoint Adjustment
Knob
Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Mode Operation
Analogue Input
Cool / Dry / Heat / Auto / Fan
Fan Speed Control
Knob
Lo-Mi1-Mi2-Hi
Setpoint Adjustment
Analogue Input
Cooling 19-30ºC
Permit / Prohibit
Digital Input
On/Off, Mode, Setpoint
Heating 17-28ºC
Airflow Direction
Knob
Horizontal - 60,80,100º swing
Auto 19-28ºC
Filter Sign
Digital Input
Normal/Reset
Fan Speed Control
Analogue Input
Lo-Mi1-Mi2-Hi
On/Off
Switch
Run/Stop
On/Off
Digital Output
Run/Stop
Mode Operation
Knob
Cool / Dry / Heat / Auto / Fan
Mode Operation
Analogue Output
Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment
Knob
Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Setpoint Adjustment
Analogue Output
Cooling 19-30ºC
Fan Speed Control
Knob
Lo-Mi1-Mi2-Hi
Heating 17-28ºC
Permit / Prohibit
Digital Output
On/Off, Mode, Setpoint
Auto 19-28ºC
Airflow Direction
Knob
Horizontal - 60,80,100º swing
Monitor
BEMS KNX-EIB Splits Interface / BEMS Trend Interface
TREND INTERFACES FUNCTION
Monitor
Fan Speed Control
Analogue Output
Lo-Mi1-Mi2-Hi
Fault Code
Sensor
4 Character code - Indicates all unit alarms
Fault Code
Analogue Output
4 Character code - Indicates all unit alarms
Filter Sign
Digital Output
-
Room Temperature
Analogue Output
-
Room Temperature
Sensor
-
*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50
Page 300
Page 301
Procon Maxi M2M-IP/50 TM
To offer remote management of its air conditioning units to companies with large numbers of dispersed offices, Mitsubishi Electric has adopted the M2M platform. The machine-to-machine (M2M) technology platform allows customers to integrate multiple sites into one network. The air conditioning units as well as third party equipment will be wirelessly connected to the M2M server and use the GPRS network to communicate. GB50ADA
Maxi M2M-IP/50
MEUK M2M SERVER
METER 1
METER 2
METER 3
METER 4
EQUIPMENT 1
EQUIPMENT 2
SENSOR 1
SENSOR 2
M2M - Machine 2 Machine Splits Interface
Controls Range
M2M - Machine 2 Machine Interface
Procon Mini M2M-A/16 TM
To offer remote management of its air conditioning units to companies with large numbers of dispersed offices, Mitsubishi Electric has adopted the M2M platform. The machine-to-machine (M2M) technology platform allows customers to integrate multiple sites into one network. The air conditioning units as well as third party equipment will be wirelessly connected to the M2M server and use the GPRS network to communicate.
Mini M2M-A/16
A1M
A1M
GPRS
Maxi M2M-IP/50
MEUK
GB50ADA
METER 1
M2M SERVER
METER 2
METER 3
METER 4
Mini M2M-A/16 METER 1
METER 2
METER 3
METER 4
EQUIPMENT 1
EQUIPMENT 2
SENSOR 1
EQUIPMENT 1
EQUIPMENT 2
SENSOR 1
SENSOR 2
GPRS
A1M
A1M
SENSOR 2
Technical Information METER 1
METER 2
METER 3
M2M INTERFACE DESCRIPTION
MAX No. OF INPUTS
22 (4 to 20mA, 0 to 10VDC, 10kΩ resistor, digital)
M2M SPLITS INTERFACE
4 (volt free contact) 12 (pulse with modulation)
FUNCTION
DESCRIPTION
MAX No. OF OUTPUTS
MAX No. OF INPUTS
8 (4 to 20mA, 0 to 10VDC, 10kΩ resistor, digital)
MAX No. OF INDOOR UNITS
50
MAX No. OF OUTPUTS
4 (pulse with modulation)
SIM CARD
Vodafone Sim Card supplied with one year contract
MAX No. OF INDOOR UNITS
16
M2M SERVER HOSTING
First year free of charge
SIM CARD
Vodafone Sim Card supplied with one year contract
POWER SUPPLY
240VAC 2A
M2M SERVER HOSTING
First year free of charge
COMPATIBILITY
City Multi, Mr Slim and M Series
POWER SUPPLY
240VAC 2A
300x70x350
COMPATIBILITY
Mr Slim and M Series via Procon A1M
DIMENSIONS - mm
M2M INTERFACE - OPERATIONAL INFORMATION FUNCTION
UP TO 25 GROUPS
UP TO 50 GROUPS
On/Off
Run/Stop
Mode Operation
Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment
Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Fan Speed Control
Lo-Mi1-Mi2-Hi
Permit / Prohibit
On/Off, Mode, Setpoint
Airflow Direction
Horizontal - 60,80,100º swing
Filter Sign
Normal/Reset
NETWORK VARIABLE
NOTES
Control
SENSOR 1
SENSOR 2
255x60x180
(WxDxH)
M2M SPLITS INTERFACE - OPERATIONAL INFORMATION FUNCTION
Monitor
NETWORK VARIABLE
NOTES
On/Off
Run/Stop
Control Mode Operation
Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment
Cooling 19-30˚C Heating 17-28˚C Auto 19-28˚C
Fan Speed Control
Lo-Mi1-Mi2-Hi
Time Zone
Weekly scheduling available
Run/Stop
Monitor
On/Off
Run/Stop
Mode Operation
Cool / Dry / Heat / Auto / Fan
On/Off
Setpoint Adjustment
Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC
Mode Operation
Cool / Dry / Heat / Auto / Fan
Fan Speed Control
Lo-Mi1-Mi2-Hi
Setpoint Adjustment
Cooling 19-30˚C
Permit / Prohibit
On/Off, Mode, Setpoint
Airflow Direction
Horizontal - 60,80,100º swing
Fault Code
Filter Sign
Room Temperature
4 Character code - Indicates all unit alarms -
-
Heating 17-28˚C Auto 19-28˚C Fan Speed Control
Lo-Mi1-Mi2-Hi
Fault Code
4 Character code – Indicates all unit alarms
Room Temperature
-
Time Zone
Weekly scheduling available
DEMONSTRATION
DEMONSTRATION
Visit m2m.mitsubishielectric.co.uk/demo to use the live demonstration space (login: demo / password: demo)
Visit m2m.mitsubishielectric.co.uk/demo to use the live demonstration space (login: demo / password: demo)
Page 302
EQUIPMENT 2
M2M Interface / M2M Splits Interface
(WxDxH)
EQUIPMENT 1
Technical Information
FUNCTION
DIMENSIONS - mm
METER 4
Page 303
M2M-Machine 2 Machine
Web Screenshots
MEUK Website
Login
M2M is accessible using MEUK website.
A username and password is required to monitor and control sites.
Monitor Active Alarms and Sites
Status
All sites are listed with active alarm sites.
A site can be selected to monitor each system.
Set Parameters
Reports
Indoor unit and third party equipment can be controlled from the Website.
Reports can be generated for analysis.
Dashboard
Administration
AG150/GB50 web pages are available for the air conditioning units
Using the administration level, the phone numbers and email of each duty engineer may be set and activated.
Procon Micro M2M-SMS-A/08 TM
The Micro M2M can monitor and control up to 8 splits systems. The Micro M2M cannot be connected to the M2M server but can be monitored and controlled using text messages (SMS).
Micro M2M-SMS-A/08
A1M
A1M
SMS Micro M2M-SMS-A/08
A1M
Controls Range
M2M - Machine 2 Machine Splits Interface
A1M
Technical Information M2M SPLITS INTERFACE FUNCTION
DESCRIPTION
MAX No. OF INDOOR UNITS
8
POWER SUPPLY
10 to 28VDC 2.5A
COMPATIBILITY
Mr Slim and M Series via Procon A1M
DIMENSIONS - mm
(WxDxH)
70x51x105
M2M SPLITS INTERFACE - OPERATIONAL INFORMATION FUNCTION
NETWORK VARIABLE
NOTES
On/Off
Run/Stop
Control Mode Operation
Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment
Cooling 19-30˚C Heating 17-28˚C Auto 19-28˚C
Fan Speed Control
Lo-Mi1-Mi2-Hi
On/Off
Run/Stop
Monitor Mode Operation
Cool / Dry / Heat / Auto / Fan
Setpoint Adjustment
Cooling 19-30˚C Heating 17-28˚C Lo-Mi1-Mi2-Hi
Fault Code
4 Character code – Indicates all unit alarms
TEXT MESSAGE EXAMPLES REGISTER (FROM MOBILE PHONE)
To register the Micro M2M to your mobile phone, just text the PIN and “ADD”. Up to 8 numbers can be registered. For example: “1234 ADD” 1234 being the last 4 digits of the serial number
MONITOR
To monitor the units, just text “STATUS” to the unit and the Micro M2M will reply with, for example: STATUS UNIT1: OK A1M COMMS: OK DRIVE:OFF ROOM TEMP:22 TEMP SETPOINT:20 MODE:AUTO FAN:HIGH
CONTROL
To switch the unit to heat mode, just text “SET” “unit name” and “HEAT” for example: “SET UNIT1 HEAT”
FAULTS
If the unit goes into fault, the Micro M2M will send a detailed text message, for example: STATUS UNIT1: FAULT A1M COMMS: FAULT CALL 0870 3000300 FOR ASSISTANCE
Technical Information Page 304
Page 305
M2M Splits Interface / M2M Web Screenshots
Auto 19-28˚C Fan Speed Control
Split-System A2M Interfaces
Procon PANEL_RS_SMS TM
The panel PANEL_RS_SMS replaces the previous run standby panels. The new panel is smaller and uses Micro M2M technology. The panel can control up to 8 indoor units and will send a text message under fault condition. The PANEL_RS_SMS does not need the SIM card to run.
Procon PANEL_RS_SMS TM
A1M
The City Multi systems use advanced communication protocol called M-NET. The Split-Systems can be interfaced to M-NET, allowing compatibility with the main centralised controller (AG150, GB50, TG2000). An A2M adapter would be required per outdoor unit for Mr Slim and per indoor unit for Mr Slim S Series or M Series indoor units.
A1M
SMS PAC-SF81MA
Controls Range
Run Standby Panel
Technical Information PROCON PANEL_RS_SMS TM
FUNCTION
DESCRIPTION
MAX No. OF INDOOR UNITS
8
FEATURES
Buzzer / Fault LED / Auto/Manual override switch / Relay for fault output
POWER SUPPLY
240VAC 2A
COMPATIBILITY
Mr Slim and M Series via Procon A1M (WxDxH)
253x90x180
TEXT MESSAGE EXAMPLES REGISTER (FROM MOBILE PHONE)
To register the Micro M2M to your mobile phone, just text the PIN and “ADD”. Up to 8 numbers can be registered. For example: “1234 ADD” 1234 being the last 4 digits of the serial number
SET UP USING A TEXT
Enter the number of units running, the number of days to switch over and the high temperature alarm, for example: “BACKUP ON, 3, 7, 27” (“ON” to activate, “3” for 3 units running, “7” to switch over every 7 days and “27” for the high temperature alarm [all the units will be switch ON])
Example: “BACKUP ON, 2, 1, 27” = 2 units running, change daily, high temperature 27ºC Unit 1
Unit 2
Unit 3
Unit 4
Day 1
2 units running, unit 3 and 4 are in standby
Day 2
2nd day, the switching over is enabled. Unit 1 and 4 are now in standby and Unit 2 and 3 are running
Day 3
3rd day, the switching over is enabled. Unit 1 and 2 are now in standby and Unit 3 and 4 are running
Day 3
On the 3rd day, the unit 4 fails
Day 3
The next unit in standby starts automatically. Unit 1 and 3 are running, 2 is in standby and 4 in fault
Day 4
The 4th day, a high temperature is detected for instance 28ºC
Day 4
All units will then start
Technical Information SPLIT-SYSTEM A2M INTERFACES FUNCTION
PAC-SF81MA
MAC-399IF
COMPATIBILITY
Mr Slim Outdoor Unit
Mr Slim S Series / M Series Indoor Unit
CONNECTION TO
Outdoor Unit
Indoor Unit
MNET SETTINGS
Rotary Switches
Dip Switches
130x15x90
160x55x70
DIMENSIONS - mm
(WxDxH)
Run Standby Panel / Split-System A2M Interfaces
DIMENSIONS - mm
NOTE: The PANEL_RS_SMS is pre-configured as a PANEL_RS1 and can be re-configured as PANEL_RS2 or PANEL_RS3 using a jumper.
Page 306
Page 307
Swing Vane Mode Auto Vane Shutter - when unit is switched off the vane automatically closes Wide Swing - distributes air laterally by up to 150º Long Airflow Mode - particularly suitable for use in long, narrow spaces Infra-red remote controller Optimised rotary or scroll compressor Econo Cool - allows set temperature to be raised by 2ºC without any loss of comfort and a 20% gain in energy efficiency Inverter control - adjusts performance to economically match the demand for heating or cooling Auto-Restart Quiet operation
the name Mitsubishi is synonymous with excellence Known the world over, Mitsubishi is a trusted global leader associated with a variety of products and services. Founded in 1921, Mitsubishi Electric quickly rose to the forefront of the air conditioning industry - a position we still enjoy today.
Mitsubishi Electric Partner Programme Open to all contractors - large or small - the Mitsubishi Electric Partner Programme offers contractors a totally new and unique set of benefits. There are two categories within the programme - Accredited Installer and Business Solutions Partner. These levels are a straight-forward reflection of the Partner’s stage of growth. All customers signing up to the programme standards are committing to continued training and professional development.
For more information please contact your local sales office
72 different airflow patterns - 2, 3 or 4 way discharge High ceiling compatibility through wide flow air outlets Auto-Changeover Hot Start - draught prevention Factory charged refrigerant up to 30m Standard filter
Unsurpassed air conditioning from Mitsubishi Electric Air conditioning is an ideal way of controlling the internal environment of any building, large or small. It does not only provide cooling when required, but also heating and often hot water can be supplied from the same system. Providing heating and hot water as part of an integrated air conditioning system is far more efficient than traditional heating methods such as gas and as a result reduced running costs and emissions can be realised. More and more people are experiencing the benefits of comfortable working, living and leisure environments made possible with air conditioning. As market leaders, we pride ourselves in providing high performance, competitive systems with low running costs and emissions.
Optional high efficiency filter Catechin filter - improves air quality and prevents the spread of bacteria and viruses within the room
Environmental Awareness
Air Cleaning filter - catches dust particles and contaminates, helping to keep the air fresh
Mitsubishi Electric boasts an explicit commitment to sustainable business practices such as energy and resource efficiency, minimising ecological impacts and reducing greenhouse gas emissions. All of our factories and UK operations are ISO14001 registered, the international standard that ensures that we are fully aware of the environmental impact of all our processes and ensures we have procedures in place to reduce them. However, we have gone far further than any accepted minimum standards. Our ‘Environmental Vision 2021’ provides a vision for a lower emission future that influences all our policy decisions. Our Green Gateway Initiative takes this vision even further as it looks to install behavioural change in our own operations and our wider sphere of influence with contractors, consultants and end users. It looks to highlight the advantages and opportunities provided, by ensuring all of our activities are undertaken with consideration to the environment. We are also proud to be a partner within Sustainable Energy Europe, whose stated aim is to raise awareness of energy use in Europe.
Anti-Allergy Enzyme filter - artificial enzyme catalyst on the filament catches allergens Nano Platinum filter - incorporates nanometre sized platinum-ceramic particles that generate stable antibacterial and deodourising effects Plasma Duo filter system Quick clean design Drain lift pump as standard Optional drain lift pump Low unit height - minimal intrusion into occupied space High external static pressure Optional high static fan motor Fresh air knockout Branch duct knockout Double thermostat function - control the temp via a sensor in the controller or the unit (wired remote controllers only) Ceiling soiling prevention Replace Technology available Refrigerant volume check function I-See Sensor Duty Standby Operation I-Save - Recalls the preferred (preset) temperature via a single button
Mitsubishi Electric Training Options Mitsubishi Electric has four state-of-the-art training suites based at different locations around the country for your convenience. Providing training for all levels of expertise, our courses are taught by experienced engineers, with a wealth of knowledge and are all CPD accredited.
For bookings please telephone 0161 866 6089
Many of our systems have an energy label of A. These systems meet the criteria of the Energy Technology List and hence could qualify for 100% first year enhanced capital allowances (whole system cost and ‘reasonable’ cost of installation). For further information please go to www.eca.gov.uk
The Forest Stewardship Council (FSC) is an international network promoting responsible management of the world's forest. The paper this catalogue is printed on supports the development of responsible forest management worldwide. The wood comes from FSC certified, well managed forests, company controlled sources and/or recycled material.
Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB. Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB. UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. UK Conditions: Winter; indoor 21˚C DB; outdoor -1˚C WB.
www.green-gateway.co.uk www.sustenergy.org www.mitsubishielectric.com/eco
Note: The fuse rating is only a typical value, it is the responsibility of a qualified electrician/electrical engineer to select the correct cable size and fuse rating based on current regulation and site specific conditions.
Corporate Sales
Birmingham
Bristol
Tel: 0870 3000 070 Fax: 0870 3000 080
Tel: 0121 741 2800 Fax: 0121 741 2801
Tel: 01454 202050 Fax: 01454 202900
Leeds
Manchester
Scotland
Tel: 0870 3300 347 Fax: 0870 3300 348
Tel: 0161 866 6060 Fax: 0161 866 6081
Tel: 01506 444960 Fax: 01506 444961
London North Region
London Central Region
London South Region
Tel: 01707 282480 Fax: 01707 282481
Tel: 0207 928 6810 Fax: 0207 928 6569
Tel: 01689 881030 Fax: 01689 881031
Ireland Tel: +353 (0)1 419 8800 Fax: +353 (0)1 419 8890 email: sales@meir.mee.com
2011 Air Conditioning Product Catalogue
Sales Offices:
The Renewable Solutions Provider
Making a World of Difference 2011 Air Conditioning Product Catalogue
After Sales Service: 0161 866 6089 email: air.conditioning@meuk.mee.com web: www.mitsubishielectric.co.uk/aircon UNITED KINGDOM Mitsubishi Electric Europe Living Environmental Systems Division Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, England General Enquiries Telephone: 01707 282880 Fax: 01707 278881 IRELAND Mitsubishi Electric Europe Westgate Business Park, Ballymount, Dublin 24, Ireland Telephone: Dublin (01) 419 8800 Fax: Dublin (01) 419 8890 International code: (003531) Country of origin: United Kingdom – Japan – Thailand – Malaysia. ©Mitsubishi Electric Europe 2011. Mitsubishi and Mitsubishi Electric are trademarks of Mitsubishi Electric Europe B.V. The company reserves the right to make any variation in technical specification to the equipment described, or to withdraw or replace products without prior notification or public announcement. Mitsubishi Electric is constantly developing and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. All goods are supplied subject to the Company’s General Conditions of Sale, a copy of which is available on request. Third-party product and brand names may be trademarks or registered trademarks of their respective owners.
Printed in November 2010
Features Key
SAP No. 237005
Air Conditioning Designed by Square Bear Limited 01604 899099. Square Bear Limited are committed to using FSC certified paper and printers, wherever possible. The sealant process used on this catalogue is environmentally friendly, recyclable and biodegradable.
Domestic Heating
Commercial Heating Photovoltaics