GAMA1411 / GAMADARIC
PRESENTATION
“
Emerging Countries
...All this in order to improve the living conditions of women and children these countries.
GAMA1411 cookstove with capacity for two pans and ‘smoke outlet’ incorporated; 5 liters of water boiling in 30 minutes;
With a small oven for heating plates; Wood consumption: 0.800 kg for 30 minutes; Estimated lifetime is six years; Warranty for manufacturing is two years.
Wood CookStove GAMA1411
CookStove Dimensions (cm) width height depth 60
32
35
Wood Entry Dimensions (cm) width height 13
Burning Dimensions (cm) width height depth
5
14
14
Table Dimensions (cm) width depth
22
60
33
Over Dimensions Weight (cm) (approximate) width height depth (kg) 28
13
21
30
Packaging Size (cm) GAMA1411
width
height
depth
60,5
33
37,5
A shipping container (High Cube) with dimensions (cm): (width) 235 (height)
269,5 x (depth) 1203,2;
x
Quan ty (1 container) GAMA1411
920 units
Rua das Matas * Zona Ind. de Cesar * Apartado 2040 * 3700-728 CESAR, PORTUGAL Tel: +351 256851488 Fax: +351 256858286 geral@gamadaric.com Cont. 507 174 798 Soc. por quotas Cap. Social: 200.000€ Mat. Cons. Reg. Comercial de Oliveira de Azeméis sob o Nº 4689/050418
GAMA1411 / GAMADARIC
“
PRESENTATION
Emerging Countries
...All this in order to improve the living conditions of women and children these countries.
Stove Manufacturer
GAMADARIC
Stove Model
GAMA1411
Testing Center
CPC-LA PAZ, BOLIVIA
Test Protocol
Water Boiling Test - Version 4.2.3
Fuel Used
Eucalyptus Grandis (Rose Gum, Grand Eucalyptus)
Pot Used
Ollas de aluminio de 5 lt
Test Dates
12,13-03
These results w ere obtained in accordance w ith the IWA and the Global Alliance for Clean Cookstoves’ reporting requirements.
.
This data and additional supporting data are shared publically through the Clean Cooking Catalog.
M. Gorritty / R. Casilla / A. García / A. Quiroz - CPC / Bolivia
Name of Tester(s)
Metric
Value
Unit
Sub-Tier
Efficiency / Fuel Use
Tier
High power Thermal Efficiency
0.3503205
%
3
Low power Specific Consumption
0.0287064
MJ/min/l
2
High power CO
13.001263
g/MJd
1
Low power CO
0.029559
g/min/l
4
High power PM 2.5
391
g/MJd
1
Low power PM 2.5
6.0661671
mg/min/l
1
3
Indoor emissions CO
0.6101442
g/min
4
Indoor emissions PM 2.5
4.9373452
mg/min
3
2
10 weighted safety parameters
77.5
Points
2
2
Emissions
Tier
1
Indoor Emissions
Tier Safety
Tier
Tier 0 Improving Importance Tier 4 Assessment Criteria Sharp Edges and Points Cookstove Tipping Containment of Fuel Obstructions Near Cooking Surface Surface Temperature Heat Transmission to Surroundings Temperature of Operational Construction Chimney Shielding Flames Surrounding the Cookpot Flames/Fuel Exiting Fuel Chamber, Canister, or Pipes
Score 1-4 4 4 4 4 1 2 2 1 4 4
Stove Rating
Fair
Stove Safety IWA Tier
2
Multiplier 1.5 3.0 2.5 2.0 2.0 2.5 2.0 2.5 3.0 4.0 Total
Subtotal 6.0 12.0 10.0 8.0 2.0 5.0 4.0 2.5 12.0 16.0 77.5
Rua das Matas * Zona Ind. de Cesar * Apartado 2040 * 3700-728 CESAR, PORTUGAL Tel: +351 256851488 Fax: +351 256858286 geral@gamadaric.com Cont. 507 174 798 Soc. por quotas Cap. Social: 200.000€ Mat. Cons. Reg. Comercial de Oliveira de Azeméis sob o Nº 4689/050418