Cables Industria Petrolera LS Cable

Page 1

Leading Solution

Offshore & Marine Cable

www.lscable.com

14F, LS Tower, 1026-6, Hogye-dong, Dongan-gu, Anyang-si, Gyeonggi-do, 431-080, Korea Tel. 82-2-2189-9114 E-mail.marine@lscable.com

2008 LS Cable, Ltd. All right reserved. This product or document is protected by copyright and distributed under licenses restricting its use, copying, distribution, and decompilation. No part of this product or document may be reproduced in any form by any means without prior written authorization of LS Cable and its licensors, if any.


Always with our customers LS Cable is leading the cable, telecommunication industry. It also represents the LS Group. With its company vision, “Always with our customers.” LS Cable continuously drives towards becoming the global leading company providing the technology as required by customers and the solution that others cannot offer.

Towards the global leading company All employees of LS Cable stand behind the vision of becoming Your No.1 Creative Partner and are doing their best to realize our customers’ satisfaction. Securing and establishing a firm growth engine, LS Cable will be reborn as an enterprise to leap worldwide

Leading Solution LS aims to develop into a company that provides its clients with a Leading Solution, contributes to the overall society, and offers a business environment where the employees can realize their dreams.

Electric Power Business Human communication connecting minds

Main energy artery lightening the world Telecommunication Business

Awakening and changing prime power

3

Reserch & Development


Cable Products Offshore & Marine Cable As a telecommunication cable manufacturer and a division of LS Cable, LS Data Communication Product and Components never stops researching, designing, developing, and manufacturing products with the higher level of quality to address the ever-changing demands in everyday life as well as in the industry. Our quality control meets the most delicate requirements of international standards and the high level of quality is recognized both by local and international clients. Our commitment to develop and deliver solutions to address our customers’ needs and challenges keep our technology on the cutting edge and our know-how in the field more valuable, which our customers highly appreciate. We are looking forward to working with you.

Contents Power Distribution Cable Power Distribution Cable - 2kV Power Distribution Cable - 0.6/1kV 0.6/1kV Control Cable 0.6/1kV Control Cable - Non Shield 0.6/1kV Control Cable - Overall Shield 0.6/1kV Control Cable - Overall Braid Shield 0.6/1kV Signal Cable 0.6/1kV Signal Cable - Overall Shield 0.6/1kV Signal Cable - Overall Braid Shield 0.6/1kV Signal Cable - Individual Shield 0.6/1kV Signal Cable - Individual & Overall Shield High Voltage Power Cable High Voltage Power Cable - 5kV, 8kV, 15kV Technical Data & Installation Information Technical Data Installation Information Network


Cable Designation According to IEEE 1580(2001), IEEE 45(2002)

Cable Type

Group Shielding

S

Single - Conductor Distribution

C

Control

D

Two - Conductor Distribution

TP

Twisted Pair

T

Three -Conductor Distribution

TT

Twisted Triad

F

Four - Conductor Distribution

FS

Fire Resistant

Q

Five - Conductor Distribution

(None) Unshielded

(OBS)

(OS)

Overall Shield

(IS-OBS) Individually Shielded and Overall Tinned

Overall Tinned Copper Braid Shielded

(IS)

Individually Shielded

Copper Braid Shielded

Power Distribution Cable - 2kv

(IS-OS) Individually Shielded and Overall Shielded

Insulation Type

Jacket and / or Sheath Type

Armor

Power Distribution Cable - 0.6/1kV

E

Ethylene Propylene Rubber

S

Silicone Rubber

X

Cross-Linked Polyethylene

P

Cross-linked Polyolefin

T

Polyvinyl Chloride

LSX

Low - smoke Cross-linked Polyolefin

T/N

Polyvinyl Chloride / Nylon

LSE

Low - smoke Ethylene Propylene Rubber

T

Thermoplastic Polyvinyl Chloride

L

Cross-linked Polyolefin (Low-smoke)

CP

Thermosetting Chlorosulfonated Polyethylene(Hypalon)

N

Thermosetting Polychloroprene(neoprene)

M

Mud resistant Cross-linked Polyolefin

TPO

Thermoplastic Polyolefin (Low-smoke)

(None) Unarmored

T

Tin-coated Copper

A

Aluminum

S

Armor with Sheath

B

Bronze

Example 0.6/1kV FS - TPNBS

Power Distribution Cable

0.6/1kV TP (I/S - OS) PNBS

Voltage

Voltage

Fire Resisrant Layer

Twisted Pair

No. of Conductor(Three)

Insulation(Type P)

Insulation(Type P)

Individually Shielded(AL/PS Tape)

Jacket(Neoprene)

Overall Shielded(AL/PS Tape)

Armor(Bronze)

Jacket(Neoprene)

Sheath(Neoprene)

Armor(Bronze) Sheath(Neoprene)

AL/PS Tape : Aluminum backed polyester tape


Power Distribution Cable - 2kV

Power Distribution Cable - 2kV SP2kV(HD), SPB2kV(HD), SPB2kV(HD)

Cable Designation / 2kV

Conductor

No. of cores

AWG/MCM Nos/AWG

Application

Unamor Conductor diameter mm

inch

Insulation thickness mm

inch

Sheath thickness mm

inch

Overall diameter mm

inch

Armor Approx Weight kg/km

Overall diameter mm

inch

Armor & Sheath Approx Weight kg/km

Overall diameter mm

inch

Approx Weight kg/km

Impedance (Phase-Neutral) /km

/1000ft

Inductance

Reactance

Capacitance

/km

/km

/km

/1000ft

/1000ft

/1000ft

1

Power Distribution Cable

SP2kV(HD), SPB2kV(HD), SPBS2kV(HD) SP2kV, SPB2kV, SPBS2kV 0.6 / 1kV SP, 0.6 / kV SPB, 0.6 / 1kV SPBS

Conductor Composition size

Suitable for use in commercial marine applications, MODU's & Platform Onshore and offshore drilling platforms FPSO, etc. 0.6/1kV Control Cable

SP2kV, SPB2kV, SPBS2kV Conductor

No.

AWG/MCM Nos/AWG

Unamor Conductor diameter mm

inch

Insulation thickness mm

inch

Sheath thickness mm

inch

Overall diameter mm

inch

Armor Approx Weight kg/km

Overall diameter mm

inch

Armor & Sheath Approx Weight kg/km

Overall diameter mm

inch

Approx Weight kg/km

Impedance (Phase-Neutral) /km

/1000ft

Inductance

Reactance

Capacitance

/km

/km

/km

/1000ft

/1000ft

/1000ft

Cable Contruction

Applied Standards & Features IEEE 1580(2001) IEEE 45(2002) UL 1309 / CSA C 22.2 No.245(1995)

Rating

100 (IEEE 1580 TYPE P) 110 (UL 1309 / CSA C 22.2 No.245) FLEXEN 125 (UL 758 125)

Feature

Flame retardant : IEC 60332-3-22 CAT.A / IEEE 1202 Cold resistant : CSA C 22.2 No.38(at -40 ) Drilling Mud Resistant(Water & oil based Mud) : NEK 606(2004) & IEC 60092-350 Ed. 3.0(2008) Crush & Impact resistant : UL 1569 & UL 2227 Excellent resistance to oil, abrasion, petrochemical fluids, moisture & sunlight. Low smoke version available (Type LSX, LSE, TPO & L) Superior flexibility

9

1

SPBS2kV(HD)

Technical Data

Standards

High Voltage Power Cable

1. CONDUCTOR : TINNED ANNEALED ROPE-LAY STRANDED COPPER 2. SEPARATOR TAPE (if necessary) 3. INSULATION(TYPE P ACCORDING TO IEEE 1580) 4. ARMOR : BRONZE WIRE BRAID *Suitable tape may be applied over / under braid armor 5. JACKET : ARCTIC NEOPRENE

0.6/1kV Signal Cable

of cores

Conductor Composition size

Offshore & Marine Cable

10


Power Distribution Cable

Power Distribution Cable

- 2kv

- 0.6/1kV

Power Distribution Cable - 0.6/1kV 0.6/1kV SP, 0.6/1kV SPB, 0.6/1kV SPBS Conductor

No.

AWG/MCM Nos/AWG

Unamor Conductor diameter mm

inch

Insulation thickness mm

inch

Sheath thickness mm

inch

Overall diameter mm

inch

Armor Approx Weight kg/km

Overall diameter mm

inch

Cable Designation / 0.6/1kV

Armor & Sheath Approx Weight kg/km

Overall diameter mm

inch

Approx Weight kg/km

Impedance (Phase-Neutral) /km

/1000ft

Inductance

Reactance

Capacitance

/km

/km

/km

/1000ft

/1000ft

0.6/1kV SPN 0.6/1kV DPN, 0.6/1kV DPNBS 0.6/1kV TPN, 0.6/1kV TPNBS 0.6/1kV FPN, 0.6/1kV FPNBS 0.6/1kV QPN, 0.6/1kV QPNBS

/1000ft

Power Distribution Cable

of cores

Conductor Composition size

Application 0.6/1kV Control Cable

Suitable for use in commercial marine applications, MODU's & Platform Onshore and offshore drilling platforms FPSO, etc. 1

0.6/1kV Signal Cable

Cable Contruction

High Voltage Power Cable

1. CONDUCTOR : TINNED ANNEALED ROPE-LAY STRANDED COPPER 2. SEPARATOR TAPE(if necessary) 3. INSULATION(TYPE P ACCORDING TO IEEE 1580) 4. FILLER 5. BINDER TAPE 6. JACKET : ARCTIC NEOPRENE 7. ARMOR : BRONZE WIRE BRAID *Suitable tape may be applied over / under braid armor 8. JACKET : ARCTIC NEOPRENE

DPNBS, TPNBS, FPNBS

Applied Standards & Features IEEE 1580(2001) IEEE 45(2002) UL 1309 / CSA C 22.2 No.245(1995)

Rating

100 (IEEE 1580 TYPE P) 110 (UL 1309 / CSA C 22.2 No.245) FLEXEN 125 (UL 758 125)

Feature

Flame retardant : IEC 60332-3-22 CAT.A / IEEE 1202 Cold resistant : CSA C 22.2 No.38(at -40 ) Drilling Mud Resistant(Water & oil based Mud) : NEK 606(2004) & IEC 60092-350 Ed. 3.0(2008) Crush & Impact resistant : UL 1569 & UL 2227

Technical Data

Standards

Excellent resistance to oil, abrasion, petrochemical fluids, moisture & sunlight. Low smoke version available (Type LSX, LSE, TPO & L) Superior flexibility 11

Offshore & Marine Cable

12


Power Distribution Cable - 0.6/1kV

0.6/1kV SPN

0.6/1kV TPN, 0.6/1kV TPNBS Conductor

Conductor

No. of cores

Conductor size

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

Sheath thickness

Overall diameter

Approx Weight

Impedance (Phase-Neutral)

Inductance

Reactance

Capacitance

No. of cores

mm

inch

mm

inch

mm

inch

kg/km

/km

/1000ft

/km

/1000ft

/km

/1000ft

/km

Conductor Composition size AWG/MCM Nos/AWG

/1000ft

Unamor Conductor diameter mm

inch

Insulation thickness mm

inch

Jacket thickness mm

inch

Sheath thickness mm

inch

Overall diameter mm

inch

Armor & Sheath Approx Weight kg/km

Overall diameter mm

inch

Approx Weight kg/km

Impedance (Phase-Neutral) /km

/1000ft

Inductance

Reactance

Capacitance

/km

/km

/km

/1000ft

/1000ft

/1000ft

Power Distribution Cable 0.6/1kV Control Cable

3

1

0.6/1kV DPN, 0.6/1kV DPNBS

0.6/1kV FPN, 0.6/1kV FPNBS

of cores

Conductor Composition size AWG/MCM Nos/AWG

Unamor Conductor diameter mm

inch

Insulation thickness mm

inch

Jacket thickness mm

inch

Sheath thickness mm

inch

Overall diameter mm

inch

Conductor

Armor & Sheath Approx Weight kg/km

Overall diameter mm

inch

Approx Weight kg/km

Impedance (Phase-Neutral)

Inductance

Reactance

Capacitance

No. of cores

/km

/1000ft

/km

/1000ft

/km

/1000ft

/km

Conductor Composition size AWG/MCM Nos/AWG

/1000ft

Unamor Conductor diameter mm

inch

Insulation thickness mm

inch

Jacket thickness mm

inch

Sheath thickness mm

inch

Overall diameter mm

inch

Armor & Sheath Approx Weight kg/km

Overall diameter mm

inch

Approx Weight kg/km

Impedance (Phase-Neutral) /km

/1000ft

Inductance

Reactance

Capacitance

/km

/km

/km

/1000ft

/1000ft

/1000ft

Technical Data

4 2

13

High Voltage Power Cable

Conductor

No.

0.6/1kV Signal Cable

14

14

Offshore & Marine Cable

14


Power Distribution Cable

Power Distribution Cable

- 0.6/1kV

- 2kV

Power Distribution Cable - 2kV

0.6/1kV QPN, 0.6/1kV QPNBS Conductor

No. of cores

Conductor Composition size AWG/MCM Nos/AWG

Unamor Conductor diameter mm

inch

Insulation thickness mm

inch

Jacket thickness mm

inch

Sheath thickness mm

inch

Overall diameter mm

inch

Armor & Sheath Approx Weight kg/km

Overall diameter mm

inch

Approx Weight kg/km

Impedance (Phase-Neutral) /km

/1000ft

Inductance

Reactance

Capacitance

/km

/km

/km

/1000ft

/1000ft

Cable Designation / 2kV

/1000ft

Power Distribution Cable

2KV TPNBS-SB/AMS

Application Suitable for use in commercial marine applications, MODU's & Platform Onshore and offshore drilling platforms FPSO, etc.

0.6/1kV Control Cable

5

0.6/1kV Signal Cable

15

Cable Contruction

High Voltage Power Cable

1. CONDUCTOR : TINNED ANNEALED ROPE-LAY STRANDED COPPER 2. SEPARATOR TAPE (if necessary) 3. INSULATION : TYPE P ( ACCORDING TO IEEE 1580) 4. FILLER : NON-HYGROSCOPIC MATERIAL (IF NECESSARY) 5. SHIELD : TINNED COPPER WIRE BRAID PLUS ALUMINUM LAMINATED POLYESTER TAPE (SB/AMS) 6. JACKET: ARCTIC NEOPRENE 7. ARMOR : BRONZE WIRE BRAID 8. JACKET: ARCTIC NEOPRENE TPNBS-SB/AMS

Applied Standards & Features IEEE 1580(2001) IEEE 45(2002) UL 1309 / CSA C 22.2 No.245(1995)

Rating

100 (IEEE 1580 TYPE P) 110 (UL 1309 / CSA C 22.2 No.245) FLEXEN 125 (UL 758 125)

Feature

Flame retardant : IEC 60332-3-22 CAT.A / IEEE 1202 Cold resistant : CSA C 22.2 No.38(at -40 ) Drilling Mud Resistant(Water & oil based Mud) : NEK 606(2004) & IEC 60092-350 Ed. 3.0(2008) Crush & Impact resistant : UL 1569 & UL 2227

Technical Data

Standards

Excellent resistance to oil, abrasion, petrochemical fluids, moisture & sunlight. Low smoke version available (Type LSX, LSE, TPO & L) Superior flexibility 15

Offshore & Marine Cable

16


Power Distribution Cable - 2kV

2kV TPNBS-SB/AMS Conductor

No. of cores

Conductor size

Composition

AWG/MCM

Nos/AWG

Conductor diameter mm

inch

Insulation thickness mm

inch

Jacket thickness mm

inch

Sheath thickness mm

inch

Overall diameter mm

inch

Approx Weight kg/km

Impedance (Phase-Neutral) /km

/1000ft

Inductance /km

/1000ft

Reactance

/km

/1000ft

Capacitance

/km

/1000ft

0.6/1kV Control Cable 0.6/1kV Control Cable - Non Shield 0.6/1kV Control Cable - With Overall Shield 3+3

17

0.6/1kV Control Cable - With Overall Braid Shield


0.6/1kV Control Cable - Non shield

0.6/1kV Control Cable - Non shield 0.6/1kV C10PN, 0.6/1kV C10PNBS

Cable Designation / 0.6/1kV

of cores

Conductor size

Compostion

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

inch

mm

mm

inch

mm

Armor & Sheath Approx. Weight

Overall diameter inch

kg/km

Approx. Weight

Overall diameter mm

inch

kg/km

2 3 4 5

Power Distribution Cable

0.6/1kV C10PN, 0.6/1kV C10PNBS 0.6/1kV C12PN, 0.6/1kV C12PNBS 0.6/1kV C14PN, 0.6/1kV C14PNBS 0.6/1kV C16PN, 0.6/1kV C16PNBS 0.6/1kV C18PN, 0.6/1kV C18PNBS

Unarmor

Conductor

No.

6

Application

7 10 12

0.6/1kV Control Cable

Suitable for use in commercial marine applications, MODU's & Platform Onshore and offshore drilling platforms FPSO, etc.

14 16 19 20 24 30 37 44 60

0.6/1kV Signal Cable

91

Cable Contruction 1. CONDUCTOR : TINNED ANNEALED ROPE-LAY STRANDED COPPER 2. SEPARATOR TAPE (if necessary) 3. INSULATION(TYPE P ACCORDING TO IEEE 1580) 4. FILLER 5. JACKET: ARCTIC NEOPRENE 6. ARMOR : BRONZE WIRE BRAID *Suitable tape may be applied over / under braid armor 7. JACKET: ARCTIC NEOPRENE

0.6/1kV C12PN, 0.6/1kV C12PNBS Unarmor

Conductor

No.

Compostion

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

mm

inch

mm

inch

mm

Armor & Sheath Approx. Weight

Overall diameter inch

kg/km

Approx. Weight

Overall diameter mm

inch

kg/km

2 3 4

C(10,12,14,16,18)TNBS

5 6

High Voltage Power Cable

of cores

Conductor size

7

Applied Standards & Features

10

Standards

14

12

Technical Data

IEEE 1580(2001) IEEE 45(2002) UL 1309 / CSA C 22.2 No.245(1995)

16 19 20

Rating

100 (IEEE 1580 TYPE P) 110 (UL 1309 / CSA C 22.2 No.245) FLEXEN 125 (UL 758 125)

24 30 37 44

Feature

Flame retardant : IEC 60332-3-22 CAT.A / IEEE 1202 Cold resistant : CSA C 22.2 No.38(at -40 ) Drilling Mud Resistant(Water & oil based Mud) : NEK 606(2004) & IEC 60092-350 Ed. 3.0(2008) Crush & Impact resistant : UL 1569 & UL 2227

60 91

Excellent resistance to oil, abrasion, petrochemical fluids, moisture & sunlight. Low smoke version available (Type LSX, LSE, TPO & L) Superior flexibility 19

Offshore & Marine Cable

20


600V Control Cable - Non shield

0.6/1kV C14PN, 0.6/1kV C14PNBS

0.6/1kV C18PN, 0.6/1kV C18PNBS Unarmor

Conductor

No.

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

inch

mm

mm

Approx. Weight

Overall diameter inch

mm

inch

kg/km

mm

inch

Unarmor

Conductor Approx. Weight

Overall diameter

No. of cores

kg/km

2

2

3

3

4

4

5

5

6

6

7

7

10

14

12

16

14

19

16

20

18

24

20

30

22

37

24

44

37

60

44

91

60

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

mm

inch

mm

inch

mm

Armor & Sheath Approx. Weight

Overall diameter inch

kg/km

Approx. Weight

Overall diameter mm

inch

kg/km

0.6/1kV Signal Cable

8

12

Composition

0.6/1kV Control Cable

10

Conductor size

Power Distribution Cable

of cores

Conductor size

Armor & Sheath

91

0.6/1kV C16PN, 0.6/1kV C16PNBS Unarmor

Conductor

No.

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

mm

inch

mm

inch

mm

Armor & Sheath Approx. Weight

Overall diameter inch

kg/km

Approx. Weight

Overall diameter mm

inch

High Voltage Power Cable

of cores

Conductor size

kg/km

2 3 4 5 6 7 8 10

Technical Data

12 14 16 18 20 22 24 37 44 60 91

21

Offshore & Marine Cable

22


0.6/1kV Control Cable - With Overall Shield

0.6/1kV Control Cable - With Overall Shield 0.6/1kV C(OS)10PN, 0.6/1kV C(OS)10PNBS

Cable Designation / 0.6/1kV

Unarmor

Conductor

No. of cores

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

inch

mm

mm

inch

mm

Armor & Sheath Approx. Weight

Overall diameter inch

kg/km

Approx. Weight

Overall diameter mm

inch

kg/km

2 3 4 5

Power Distribution Cable

0.6/1kV C(OS)10PN, 0.6/1kV C(OS)10PNBS 0.6/1kV C(OS)12PN, 0.6/1kV C(OS)12PNBS 0.6/1kV C(OS)14PN, 0.6/1kV C(OS)14PNBS 0.6/1kV C(OS)16PN, 0.6/1kV C(OS)16PNBS 0.6/1kV C(OS)18PN, 0.6/1kV C(OS)18PNBS 0.6/1kV C(OS)20PN, 0.6/1kV C(OS)20PNBS

Conductor size

6 7

Application

10 12

0.6/1kV Control Cable

Suitable for use in commercial marine applications, MODU's & Platform Onshore and offshore drilling platforms FPSO, etc.

14 16 19 20 24 30 37 44 60

0.6/1kV Signal Cable

91

Cable Contruction 0.6/1kV C(OS)12PN, 0.6/1kV C(OS)12PNBS Unarmor

Conductor

No. of cores

Conductor size

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

mm

inch

mm

inch

mm

Armor & Sheath Approx. Weight

Overall diameter inch

kg/km

Approx. Weight

Overall diameter mm

inch

kg/km

2 3 4

C(OS)16,14,12,10PN

5 6

High Voltage Power Cable

1. CONDUCTOR : TINNED ANNEALED ROPE-LAY STRANDED COPPER *For fire resisting cables, FS-type, mica tape shall be applied over the conductor as a fire proof layer 2. SEPARATOR TAPE (if necessary) 3. INSULATION(TYPE P ACCORDING TO IEEE 1580) 4. FILLER 5. SHIELDING: ALUMINUM POLYESTER TAPE 6. DRAIN WIRE 7. JACKET: ARCTIC NEOPRENE 8. ARMOR: BRONZE WIRE BRAID 9. JACKET: ARCTIC NEOPRENE

7

Applied Standards & Features

10

Standards

14

12

Technical Data

IEEE 1580(2001) IEEE 45(2002) UL 1309 / CSA C 22.2 No.245(1995)

16 19 20

Rating

100 (IEEE 1580 TYPE P) 110 (UL 1309 / CSA C 22.2 No.245) FLEXEN 125 (UL 758 125)

24 30 37 44

Feature

Flame retardant : IEC 60332-3-22 CAT.A / IEEE 1202 Cold resistant : CSA C 22.2 No.38(at -40 ) Drilling Mud Resistant(Water & oil based Mud) : NEK 606(2004) & IEC 60092-350 Ed. 3.0(2008) Crush & Impact resistant : UL 1569 & UL 2227

60 91

Excellent resistance to oil, abrasion, petrochemical fluids, moisture & sunlight. Low smoke version available (Type LSX, LSE, TPO & L) Superior flexibility 23

Offshore & Marine Cable

24


0.6/1kV Control Cable - With Overall Shield

0.6/1kV C(OS)14PN, 0.6/1kV C(OS)14PNBS

0.6/1kV C(OS)18PN, 0.6/1kV C(OS)18PNBS Unarmor

Conductor

No.

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

inch

mm

mm

Approx. Weight

Overall diameter inch

mm

inch

kg/km

mm

inch

Unarmor

Conductor Approx. Weight

Overall diameter

No. of cores

kg/km

2

2

3

3

4

4

5

5

6

6

7

7

10

14

12

16

14

19

16

20

18

24

20

30

22

37

24

44

37

60

44

91

60

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

inch

mm

mm

inch

mm

Armor & Sheath Approx. Weight

Overall diameter inch

kg/km

Approx. Weight

Overall diameter mm

inch

kg/km

0.6/1kV Signal Cable

8

12

Composition

0.6/1kV Control Cable

10

Conductor size

91

0.6/1kV C(OS)16PN, 0.6/1kV C(OS)16PNBS

0.6/1kV C(OS)20PN, 0.6/1kV C(OS)20PNBS Unarmor

Conductor

No.

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

mm

inch

mm

Approx. Weight

Overall diameter inch

mm

Armor & Sheath

inch

kg/km

mm

inch

No. of cores

kg/km

2

2

3

3

4

4

5

5

6

6

7

7 8

10

10

12

12

14

14

16

16

18

18

20

20

22

22

24

24

37

37

44

44

60

60

91

91

Conductor size

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

mm

inch

mm

inch

mm

Armor & Sheath Approx. Weight

Overall diameter inch

kg/km

Approx. Weight

Overall diameter mm

inch

kg/km

Technical Data

8

25

Unarmor

Conductor Approx. Weight

Overall diameter

High Voltage Power Cable

of cores

Conductor size

Power Distribution Cable

of cores

Conductor size

Armor & Sheath

Offshore & Marine Cable

26


0.6/1kV Control Cable - With Overall Braid Shield

0.6/1kV Control Cable - With Overall Braid Shield 0.6/1kV C(OBS)14PN, 0.6/1kV C(OBS)14PNBS

Cable Designation / 0.6/1kV

Unarmor

Conductor

No. of cores

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

inch

mm

mm

inch

mm

Armor & Sheath Approx. Weight

Overall diameter inch

kg/km

Approx. Weight

Overall diameter mm

inch

kg/km

2 3 4 5

Application

Power Distribution Cable

0.6/1kV C(OBS)14PN, 0.6/1kV C(OBS)14PNBS 0.6/1kV C(OBS)16PN, 0.6/1kV C(OBS)16PNBS 0.6/1kV C(OBS)18PN, 0.6/1kV C(OBS)18PNBS 0.6/1kV C(OBS)20PN, 0.6/1kV C(OBS)20PNBS

Conductor size

6 7 10 12

0.6/1kV Control Cable

Suitable for use in commercial marine applications, MODU's & Platform Onshore and offshore drilling platforms FPSO, etc.

14 16 19 20 24 30 37 44 60

0.6/1kV Signal Cable

91

Cable Contruction 0.6/1kV C(OBS)16PN, 0.6/1kV C(OBS)16PNBS Unarmor

Conductor

No. of cores

Conductor size

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

mm

inch

mm

inch

mm

Armor & Sheath Approx. Weight

Overall diameter inch

kg/km

Approx. Weight

Overall diameter mm

inch

kg/km

2 3 4

C(OS)16,14.12,10PN

5 6

High Voltage Power Cable

1. CONDUCTOR : TINNED ANNEALED ROPE-LAY STRANDED COPPER *For fire resisting cables, FS-type, mica tape shall be applied over the conductor as a fire proof layer 2. SEPARATOR TAPE (if necessary) 3. INSULATION(TYPE P ACCORDING TO IEEE 1580) 4. FILLER 5. SHIELDING: TINNED COPPER WIRE BRAID 6. JACKET: ARCTIC NEOPRENE 7. ARMOR: BRONZE WIRE BRAID 8. JACKET: ARCTIC NEOPRENE

7

Applied Standards & Features

10

Standards

12

Technical Data

IEEE 1580(2001) IEEE 45(2002) UL 1309 / CSA C 22.2 No.245(1995)

8

14 16 18

Rating

100 (IEEE 1580 TYPE P) 110 (UL 1309 / CSA C 22.2 No.245) FLEXEN 125 (UL 758 125)

20 22 24 37

Feature

Flame retardant : IEC 60332-3-22 CAT.A / IEEE 1202 Cold resistant : CSA C 22.2 No.38(at -40 ) Drilling Mud Resistant(Water & oil based Mud) : NEK 606(2004) & IEC 60092-350 Ed. 3.0(2008) Crush & Impact resistant : UL 1569 & UL 2227

44 60 91

Excellent resistance to oil, abrasion, petrochemical fluids, moisture & sunlight. Low smoke version available (Type LSX, LSE, TPO & L) Superior flexibility 27

Offshore & Marine Cable

28


0.6/1kV Control Cable - With Overall Braid Shield

0.6/1kV C(OBS)18PN, 0.6/1kV C(OBS)18PNBS Unarmor

Conductor

No. of cores

Conductor size

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

inch

mm

mm

inch

mm

Armor & Sheath Approx. Weight

Overall diameter inch

kg/km

Approx. Weight

Overall diameter mm

inch

kg/km

2 3

0.6/1kV Signal Cable

4 5

0.6/1kV Signal Cable - Overall Shield

6

0.6/1kV Signal Cable - Overall Braid Shield

7

0.6/1kV Signal Cable - Individual Shield

8

0.6/1kV Signal Cable - Individual & Overall Shield

10 12 14 16 18 20 22 24 37 44 60 91

0.6/1kV C(OBS)20PN, 0.6/1kV C(OBS)20PNBS Unarmor

Conductor

No. of cores 2 3 4 5 6 7 8 10 12 14 16 18 20 22 24 37 44 60 91

29

Conductor size

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

mm

inch

mm

inch

mm

Armor & Sheath Approx. Weight

Overall diameter inch

kg/km

Approx. Weight

Overall diameter mm

inch

kg/km


0.6/1kV Signal Cable - With Overall Shield

0.6/1kV Signal Cable - With Overall Shield 0.6/1kV TP(OS)14PN, 0.6/1kV TP(OS)14PNBS

Cable Designation / 0.6/1kV

Unarmor

Conductor

No. of Pairs

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

inch

mm

mm

inch

mm

Armor & Sheath Approx. Weight

Overall diameter inch

kg/km

Approx. Weight

Overall diameter mm

inch

kg/km

1 2 3 4

Power Distribution Cable

0.6/1kV TP(OS)14PN, 0.6/1kV TP(OS)14PNBS 0.6/1kV TP(OS)16PN, 0.6/1kV TP(OS)16PNBS 0.6/1kV TP(OS)18PN, 0.6/1kV TP(OS)18PNBS 0.6/1kV TP(OS)20PN, 0.6/1kV TP(OS)20PNBS 0.6/1kV TP(OS)22PN, 0.6/1kV TP(OS)22PNBS 0.6/1kV TT(OS)16PN, 0.6/1kV TT(OS)16PNBS 0.6/1kV TT(OS)18PN, 0.6/1kV TT(OS)18PNBS 0.6/1kV TT(OS)20PN, 0.6/1kV TT(OS)20PNBS

Conductor size

5 6 7 8

0.6/1kV Control Cable

Application

9

Suitable for use in commercial marine applications, MODU's & Platform Onshore and offshore drilling platforms FPSO, etc.

10 12 14 16 24

0.6/1kV Signal Cable

Cable Contruction 0.6/1kV TP(OS)16PN, 0.6/1kV TP(OS)16PNBS Unarmor

Conductor

No. of pairs

Conductor size

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

mm

inch

mm

inch

mm

Armor & Sheath Approx. Weight

Overall diameter inch

kg/km

Approx. Weight

Overall diameter mm

inch

kg/km

1 2

TP(OS)14,16,18PNBS

3 4 5

High Voltage Power Cable

1. CONDUCTOR : TINNED ANNEALED ROPE-LAY STRANDED COPPER 2. SEPARATOR TAPE (if necessary) 3. INSULATION(TYPE P ACCORDING TO IEEE 1580) 4. FILLER 5. BINDER TAPE 6. DRAIN WIRE 7. SHIELDING : ALUMINUM POLYESTER TAPE 8. JACKET : ARCTIC NEOPRENE 9. ARMOR : BRONZE WIRE BRAID *Suitable tape may be applied over/under braid armor 10. JACKET : ARCTIC NEOPRENE

6

Applied Standards & Features IEEE 1580(2001) IEEE 45(2002) UL 1309 / CSA C 22.2 No.245(1995)

8 9

Technical Data

Standards

7

10 12 14

Rating

Feature

100 (IEEE 1580 TYPE P) 110 (UL 1309 / CSA C 22.2 No.245) FLEXEN 125 (UL 758 125)

16 24

Flame retardant : IEC 60332-3-22 CAT.A / IEEE 1202 Cold resistant : CSA C 22.2 No.38(at -40 ) Drilling Mud Resistant(Water & oil based Mud) : NEK 606(2004) & IEC 60092-350 Ed. 3.0(2008) Crush & Impact resistant : UL 1569 & UL 2227 Excellent resistance to oil, abrasion, petrochemical fluids, moisture & sunlight. Low smoke version available (Type LSX, LSE, TPO & L) Superior flexibility

31

Offshore & Marine Cable

32


0.6/1kV Signal Cable - With Overall Shield

0.6/1kV TP(OS)18PN, 0.6/1kV TP(OS)18PNBS

0.6/1kV TP(OS)22PN, 0.6/1kV TP(OS)22PNBS Unarmor

Conductor

No.

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

inch

mm

mm

Approx. Weight

Overall diameter inch

mm

inch

kg/km

mm

inch

Unarmor

Conductor Approx. Weight

Overall diameter

No. of pairs

kg/km

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8 9

10

10

12

12

14

14

16

16

24

24

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

inch

mm

mm

inch

mm

Armor & Sheath Approx. Weight

Overall diameter inch

kg/km

Approx. Weight

Overall diameter mm

inch

kg/km

0.6/1kV Control Cable

9

Conductor size

Power Distribution Cable

of pairs

Conductor size

Armor & Sheath

0.6/1kV Signal Cable

0.6/1kV TP(OS)20PN, 0.6/1kV TP(OS)20PNBS

0.6/1KV TT(OS)16PN, 0.6/1KV TT(OS)16PNBS Unarmor

Conductor

No.

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

mm

inch

mm

Approx. Weight

Overall diameter inch

mm

inch

kg/km

mm

inch

Unarmor

Conductor Approx. Weight

Overall diameter

No. of pairs

kg/km

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8 9

10

10

12

12

14

14

16

16

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

mm

inch

mm

inch

mm

Armor & Sheath Approx. Weight

Overall diameter inch

kg/km

Approx. Weight

Overall diameter mm

inch

kg/km

Technical Data

9

Conductor size

24

33

High Voltage Power Cable

of pairs

Conductor size

Armor & Sheath

Offshore & Marine Cable

34


0.6/1kV Signal Cable

0.6/1kV Signal Cable

- With Overall Shield

- With Overall Braid Shield Pair Twisted

0.6/1kV Signal Cable - With Overall Braid Shield Pair Twisted 0.6/1kV TT(OS)18PN, 0.6/1kV TT(OS)18PNBS Unarmor

Conductor

No.

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

inch

mm

mm

inch

mm

inch

Cable Designation / 0.6/1kV

Armor & Sheath Approx. Weight

Overall diameter

kg/km

Approx. Weight

Overall diameter mm

inch

0.6/1kV TP(OBS)16PN, 0.6/1kV TP(OBS)16PNBS 0.6/1kV TP(OBS)18PN, 0.6/1kV TP(OBS)18PNBS 0.6/1kV TP(OBS)20PN, 0.6/1kV TP(OBS)20PNBS

kg/km

1 2

Power Distribution Cable

of triads

Conductor size

3

Application

4 5

7 8

0.6/1kV Control Cable

Suitable for use in commercial marine applications, MODU's & Platform Onshore and offshore drilling platforms FPSO, etc.

6

9 10 12 14 16

0.6/1kV Signal Cable

Cable Contruction 0.6/1kV TT(OS)20PN, 0.6/1kV TT(OS)20PNBS Unarmor

Conductor

No.

1 2 3 4

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

mm

inch

mm

inch

mm

Armor & Sheath Approx. Weight

Overall diameter inch

kg/km

Approx. Weight

Overall diameter mm

inch

kg/km

High Voltage Power Cable

of triads

Conductor size

1. CONDUCTOR : TINNED ANNEALED ROPE-LAY STRANDED COPPER 2. SEPARATOR TAPE (if necessary) 3. INSULATION(TYPE P ACCORDING TO IEEE 1580) 4. FILLER 5. BINDER TAPE 6. SHIELDING : TINNED COPPER BRAID 7. JACKET : ARCTIC NEOPRENE 8. ARMOR : BRONZE WIRE BRAID *Suitable tape may be applied over/under braid armor 9. JACKET : ARCTIC NEOPRENE

TP(OBS)14,16,18NBS

5 6

Applied Standards & Features

9

Standards

IEEE 1580(2001) IEEE 45(2002) UL 1309 / CSA C 22.2 No.245(1995)

Rating

100 (IEEE 1580 TYPE P) 110 (UL 1309 / CSA C 22.2 No.245) FLEXEN 125 (UL 758 125)

Feature

Flame retardant : IEC 60332-3-22 CAT.A / IEEE 1202 Cold resistant : CSA C 22.2 No.38(at -40 ) Drilling Mud Resistant(Water & oil based Mud) : NEK 606(2004) & IEC 60092-350 Ed. 3.0(2008) Crush & Impact resistant : UL 1569 & UL 2227

10 12

Technical Data

8

7

14 16

Excellent resistance to oil, abrasion, petrochemical fluids, moisture & sunlight. Low smoke version available (Type LSX, LSE, TPO & L) Superior flexibility 35

Offshore & Marine Cable

36


0.6/1kV Signal Cable - With Overall Braid Shield Pair Twisted

0.6/1kV TP(OBS)16PN, 0.6/1kV TP(OBS)16PNBS

0.6/1kV TP(OBS)20PN, 0.6/1kV TP(OBS)20PNBS Unarmor

Conductor

No.

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

inch

mm

mm

Approx. Weight

Overall diameter inch

mm

inch

kg/km

mm

inch

Unarmor

Conductor Approx. Weight

Overall diameter

No. of pairs

kg/km

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8 9

10

10

12

12

14

14

16

16

24

24

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

mm

inch

mm

inch

mm

Armor & Sheath Approx. Weight

Overall diameter inch

kg/km

Approx. Weight

Overall diameter mm

inch

kg/km

0.6/1kV Control Cable

9

Conductor size

Power Distribution Cable

of pairs

Conductor size

Armor & Sheath

0.6/1kV Signal Cable

0.6/1kV TP(OBS)18PN, 0.6/1kV TP(OBS)18PNBS Unarmor

Conductor

No.

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

mm

inch

mm

inch

mm

Armor & Sheath Approx. Weight

Overall diameter inch

kg/km

Approx. Weight

Overall diameter mm

inch

High Voltage Power Cable

of pairs

Conductor size

kg/km

1 2 3 4 5 6 7 8

Technical Data

9 10 12 14 16 24

37

Offshore & Marine Cable

38


0.6/1kV Signal Cable - With Individual Shield Pair Twisted

0.6/1kV Signal Cable - With Individual Shield Pair Twisted 0.6/1kV TP(I/S)14PN, 0.6/1kV TP(I/S)14PNBS

Cable Designation / 0.6/1kkV

Unarmor

Conductor

No. of pairs

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

inch

mm

mm

inch

mm

Armor & Sheath Approx. Weight

Overall diameter inch

kg/km

Approx. Weight

Overall diameter mm

inch

kg/km

2 3 4 5

Power Distribution Cable

0.6/1kV TP(I/S)14PN, 0.6/1kV TP(I/S)14PNBS 0.6/1kV TP(I/S)16PN, 0.6/1kV TP(I/S)16PNBS 0.6/1kV TP(I/S)18PN, 0.6/1kV TP(I/S)18PNBS 0.6/1kV TP(I/S)20PN, 0.6/1kV TP(I/S)20PNBS 0.6/1kV TT(I/S)16PN, 0.6/1kV TT(I/S)16PNBS 0.6/1kV TT(I/S)18PN, 0.6/1kV TT(I/S)18PNBS 0.6/1kV TT(I/S)20PN, 0.6/1kV TT(I/S)20PNBS

Conductor size

6 7 8 9

0.6/1kV Control Cable

Application

10

Suitable for use in commercial marine applications, MODU's & Platform Onshore and offshore drilling platforms

12

FPSO, etc.

16

14

18 24

0.6/1kV Signal Cable

Cable Contruction 0.6/1kV TP(I/S)16PN, 0.6/1kV TP(I/S)16PNBS Unarmor

Conductor

No. of pairs

Conductor size

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

mm

inch

mm

inch

mm

Armor & Sheath Approx. Weight

Overall diameter inch

kg/km

Approx. Weight

Overall diameter mm

inch

kg/km

2 3

TP(I/S)16PNBS

4 5 6

High Voltage Power Cable

1. CONDUCTOR : TINNED ANNEALED ROPE-LAY STRANDED COPPER 2. SEPARATOR TAPE (if necessary) 3. INSULATION(TYPE P ACCORDING TO IEEE 1580) 4. BINDER TAPE 5. DRAIN WIRE 6. SHIELDING : ALUMINUM POLYESTER TAPE 7. FILLER 8. JACKET : ARCTIC NEOPRENE 9. ARMOR : BRONZE WIRE BRAID *Suitable tape may be applied over/under braid armor 10. JACKET : ARCTIC NEOPRENE

7

Applied Standards & Features

8

Standards

10

9

Technical Data

IEEE 1580(2001) IEEE 45(2002) UL 1309 / CSA C 22.2 No.245(1995)

12 14 16

Rating

Feature

100 (IEEE 1580 TYPE P) 110 (UL 1309 / CSA C 22.2 No.245) FLEXEN 125 (UL 758 125)

18 24

Flame retardant : IEC 60332-3-22 CAT.A / IEEE 1202 Cold resistant : CSA C 22.2 No.38(at -40 ) Drilling Mud Resistant(Water & oil based Mud) : NEK 606(2004) & IEC 60092-350 Ed. 3.0(2008) Crush & Impact resistant : UL 1569 & UL 2227 Excellent resistance to oil, abrasion, petrochemical fluids, moisture & sunlight. Low smoke version available (Type LSX, LSE, TPO & L) Superior flexibility

39

Offshore & Marine Cable

40


0.6/1kV Signal Cable - With Individual Shield Pair Twisted

0.6/1kV TP(I/S)18PN, 0.6/1kV TP(I/S)18PNBS

0.6/1kV TT(I/S)16PN, 0.6/1kV TT(I/S)16PNBS Unarmor

Conductor

No.

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

inch

mm

mm

Approx. Weight

Overall diameter inch

mm

inch

kg/km

mm

inch

Unarmor

Conductor Approx. Weight

Overall diameter

No. of pairs

kg/km

2

2

3

3

4

4

5

5

6

6

7

7

8

8 9

10

10

12

12

14

14

16

16

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

inch

mm

mm

inch

mm

Armor & Sheath Approx. Weight

Overall diameter inch

kg/km

Approx. Weight

Overall diameter mm

inch

kg/km

0.6/1kV Control Cable

9

Conductor size

Power Distribution Cable

of pairs

Conductor size

Armor & Sheath

18 24

0.6/1kV Signal Cable

0.6/1kV TP(I/S)20PN, 0.6/1kV TP(I/S)20PNBS

0.6/1KV TT(I/S)18PN, 0.6/1KV TT(I/S)18PNBS Unarmor

Conductor

No.

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

mm

inch

mm

Approx. Weight

Overall diameter inch

mm

inch

kg/km

mm

inch

Unarmor

Conductor Approx. Weight

Overall diameter

No. of pairs

kg/km

2

2

3

3

4

4

5

5

6

6

7

7

8

8 9

10

10

12

12

14

14

16

16

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

mm

inch

mm

inch

mm

Armor & Sheath Approx. Weight

Overall diameter inch

kg/km

Approx. Weight

Overall diameter mm

inch

kg/km

Technical Data

9

Conductor size

18 24

41

High Voltage Power Cable

of pairs

Conductor size

Armor & Sheath

Offshore & Marine Cable

42


0.6/1kV Signal Cable

0.6/1kV Signal Cable

- With Individual Shield Pair Twisted

- With Individual & Overall Shield

0.6/1kV Signal Cable - With Individual & Overall Shield 0.6/1kV TT(I/S)20PN, 0.6/1kV TT(I/S)20PNBS Unarmor

Conductor

No.

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

mm

inch

mm

inch

mm

inch

Cable Designation / 0.6/1kV

Armor & Sheath Approx. Weight

Overall diameter

kg/km

Approx. Weight

Overall diameter mm

inch

0.6/1kV TP(I/S-OS)14PN, 0.6/1kV TP(I/S-OS)14PNBS 0.6/1kV TP(I/S-OS)16PN, 0.6/1kV TP(I/S-OS)16PNBS 0.6/1kV TP(I/S-OS)18PN, 0.6/1kV TP(I/S-OS)18PNBS 0.6/1kV TP(I/S-OS)20PN, 0.6/1kV TP(I/S-OS)20PNBS 0.6/1kV TT(I/S-OS)16PN, 0.6/1kV TT(I/S-OS)16PNBS 0.6/1kV TT(I/S-OS)18PN, 0.6/1kV TT(I/S-OS)18PNBS 0.6/1kV TT(I/S-OS)20PN, 0.6/1kV TT(I/S-OS)20PNBS

kg/km

2 3 4 5 6 7

Power Distribution Cable

of pairs

Conductor size

8 9

0.6/1kV Control Cable

Application

10

Suitable for use in commercial marine applications, MODU's & Platform Onshore and offshore drilling platforms

12 14 16

FPSO, etc.

0.6/1kV Signal Cable

Cable Contruction

High Voltage Power Cable

1. CONDUCTOR : TINNED ANNEALED ROPE-LAY STRANDED COPPER 2. SEPARATOR TAPE (if necessary) 3. INSULATION(TYPE P ACCORDING TO IEEE 1580) 4. BINDER TAPE 5. DRAIN WIRE 6. SHIELDING : ALUMINUM POLYSTER TAPE 7. FILLER 8. JACKET : ARCTIC NEOPRENE 9. ARMOR : BRONZE WIRE BRAID *Suitable tape may be applied over/under braid armor 10. JACKET : ARCTIC NEOPRENE

TP(I/S-OS)16,18,20PNBS

Applied Standards & Features IEEE 1580(2001) IEEE 45(2002) UL 1309 / CSA C 22.2 No.245(1995)

Rating

100 (IEEE 1580 TYPE P) 110 (UL 1309 / CSA C 22.2 No.245) FLEXEN 125 (UL 758 125)

Feature

Flame retardant : IEC 60332-3-22 CAT.A / IEEE 1202 Cold resistant : CSA C 22.2 No.38(at -40 ) Drilling Mud Resistant(Water & oil based Mud) : NEK 606(2004) & IEC 60092-350 Ed. 3.0(2008) Crush & Impact resistant : UL 1569 & UL 2227

Technical Data

Standards

Excellent resistance to oil, abrasion, petrochemical fluids, moisture & sunlight. Low smoke version available (Type LSX, LSE, TPO & L) Superior flexibility 43

Offshore & Marine Cable

44


0.6/1kV Signal Cable - With Individual & Overall Shield

0.6/1kV TP(I/S-OS)14PN, 0.6/1kV TP(I/S-OS)14PNBS

0.6/1kV TP(I/S-OS)18PN, 0.6/1kV TP(I/S-OS)18PNBS Unarmor

Conductor

No.

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

inch

mm

mm

Approx. Weight

Overall diameter inch

mm

inch

kg/km

mm

inch

Unarmor

Conductor Approx. Weight

Overall diameter

No. of pairs

kg/km

2

2

3

3

4

4

5

5

6

6

7

7

8

8 9

10

10

12

12

14

14

16

16

18

18

24

24

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

inch

mm

mm

inch

mm

Armor & Sheath Approx. Weight

Overall diameter inch

kg/km

Approx. Weight

Overall diameter mm

inch

kg/km

0.6/1kV Control Cable

9

Conductor size

Power Distribution Cable

of pairs

Conductor size

Armor & Sheath

0.6/1kV Signal Cable

0.6/1kV TP(I/S-OS)16PN, 0.6/1kV TP(I/S-OS)16PNBS

0.6/1kV TP(I/S-OS)20PN, 0.6/1kV TP(I/S-OS)20PNBS Unarmor

Conductor

No.

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

mm

inch

mm

Approx. Weight

Overall diameter inch

mm

inch

kg/km

mm

inch

No. of pairs

kg/km

2

2

3

3

4

4

5

5

6

6

7

7

8

8 9

10

10

12

12

14

14

16

16

18

18

24

24

Conductor size

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

mm

inch

mm

inch

mm

Armor & Sheath Approx. Weight

Overall diameter inch

kg/km

Approx. Weight

Overall diameter mm

inch

kg/km

Technical Data

9

45

Unarmor

Conductor Approx. Weight

Overall diameter

High Voltage Power Cable

of pairs

Conductor size

Armor & Sheath

Offshore & Marine Cable

46


0.6/1kV Signal Cable - With Individual & Overall Shield

0.6/1kV TT(I/S-OS)16PN, 0.6/1kV TT(I/S-OS)16PNBS Unarmor

Conductor

No. of pairs

Conductor size

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

inch

mm

mm

inch

mm

Armor & Sheath Approx. Weight

Overall diameter inch

kg/km

Approx. Weight

Overall diameter mm

inch

kg/km

High Voltage Power Cable

2 3 4 5

High Voltage Power Cable- 5kV, 8kV, 15kV

6 7 8 9 10 12 14 16

0.6/1kV TT(I/S-OS)18PN, 0.6/1kV TT(I/S-OS)18PNBS Unarmor

Conductor

No. of pairs

Conductor size

Composition

AWG/MCM

Nos/AWG

Insulation thickness

Conductor diameter mm

inch

mm

Sheath thickness

Jacket thickness inch

inch

mm

mm

inch

mm

Armor & Sheath Approx. Weight

Overall diameter inch

kg/km

Approx. Weight

Overall diameter mm

inch

kg/km

2 3 4 5 6 7 8 9 10 12 14 16

0.6/1kV TT(I/S-OS)20PN, 0.6/1kV TT(I/S-OS)20PNBS of pairs 2 3 4 5 6 7 8 9 10 12 14 16

47

Conductor size

Composition

AWG/MCM

Nos/AWG

Armor & Sheath

Unarmor

Conductor

No.

Insulation thickness

Conductor diameter mm

inch

mm

Jacket thickness inch

mm

Sheath thickness inch

mm

Approx. Weight

Overall diameter inch

mm

inch

kg/km

Approx. Weight

Overall diameter mm

inch

kg/km


High Voltage Power Cable - 5kV, 8kV, 15kV

High Voltage Power Cable - 5kV, 8kv, 15kV 5kV SEN(BS), 5kV SEL(BS) (100% Insulation level)

Cable Designation / 5kV,8kV,15kV

of cores

Conductor Composition size AWG/MCM Nos/AWG

Unarmor Conductor diameter mm

inch

Insulation thickness mm

inch

Jacket thickness mm

inch

Sheath thickness mm

inch

Overall diameter mm

inch

Armor & Sheath Approx Weight kg/km

Overall diameter mm

inch

Approx Weight kg/km

Impedance (Phase-Neutral) /km

/1000ft

Inductance

Reactance

Capacitance

/km

/km

/km

/1000ft

/1000ft

/1000ft

Power Distribution Cable

5kV SEN(BS), 5kV SEL(BS) (100%, 133% Insulation level) 5kV TEN(BS), 5kV TEL(BS) (100%, 133% Insulation level) 8kV SEN(BS), 8kV SEL(BS)) (100%, 133% Insulation level) 8kV TEN(BS), 8kV TEL(BS)) (100%, 133% Insulation level) 15kV SEN(BS), 15kV SEL(BS)) (100%, 133% Insulation level) 15kV TEN(BS), 15kV TEL(BS) (100%, 133% Insulation level)

Conductor

No.

Application 0.6/1kV Control Cable

Suitable for use in commercial marine applications, MODU's & Platform Onshore and offshore drilling platforms FPSO, etc.

1

0.6/1kV Signal Cable

Cable Contruction 1. CONDUCTOR : TINNED ANNEALED ROPE-LAY STRANDED COPPER 2. CONDUCTOR SHIELDING : SEMI-CONDUCTIING TAPE AND COMPOUND 3. INSULATION : ERR(ETHYLENE PROPYLENE RUBBER) 4. INSULATION SHIELD(NON-METALLIC MATERIAL : SEMI-CONDUCTING TAPE/COMPOUND) 5. INSULATION SHIELD(METAILIC) : TINNED COPPER WIRE BRAID 6.JACKET: ARCTIC NEOPRENE

5kV SEN(BS), 5kV SEL(BS) (133% Insulation level) of cores

Conductor Composition size AWG/MCM Nos/AWG

Applied Standards & Features Standards

Rating

90 (IEEE 1580 TYPE E) 105 (UL 1309 / CSA C 22.2 No.245)

Feature

Flame retardant : IEC 60332-3-22 CAT.A / IEEE 1202 Cold resistant : CSA C 22.2 No.38(at -40 ) Drilling Mud Resistant(Water & oil based Mud) : NEK 606(2004) & IEC 60092-350 Ed. 3.0(2008)" Crush & Impact resistant : UL 1569 & UL 2227 Excellent resistance to oil, abrasion, petrochemical fluids, moisture & sunlight. Low smoke version available (Type LSX, LSE, TPO & L) Superior flexibility

49

mm

inch

Insulation thickness mm

inch

Jacket thickness mm

inch

Sheath thickness mm

inch

Overall diameter mm

inch

Armor & Sheath Approx Weight kg/km

Overall diameter mm

inch

Approx Weight kg/km

Impedance (Phase-Neutral) /km

/1000ft

Inductance

Reactance

Capacitance

/km

/km

/km

/1000ft

/1000ft

/1000ft

5kV/8kV/15kV TENBS

Technical Data

IEEE 1580(2001) IEEE 45(2002) ICEA S 93-639(20000) UL 1072(2001) UL 1309 / CSA C 22.2 No.245(1995)

Unarmor Conductor diameter

High Voltage Power Cable

Conductor

No.

1

Offshore & Marine Cable

50


High Voltage Power Cable - 5kV, 8kV, 15kV

5kV TEN(BS), 5kV TEL(BS) (100% Insulation level) Conductor

No.

AWG/MCM Nos/AWG

Conductor diameter mm

inch

Insulation thickness mm

inch

Jacket thickness mm

inch

Sheath thickness mm

inch

Overall diameter mm

inch

Conductor

Armor & Sheath Approx Weight kg/km

Overall diameter mm

inch

Approx Weight kg/km

Impedance (Phase-Neutral)

Inductance

Reactance

Capacitance

No. of cores

/km

/1000ft

/km

/1000ft

/km

/1000ft

/km

Conductor Composition size AWG/MCM Nos/AWG

/1000ft

Unarmor Conductor diameter mm

inch

Insulation thickness mm

inch

Jacket thickness mm

inch

Sheath thickness mm

inch

Overall diameter mm

inch

Armor & Sheath Approx Weight kg/km

Overall diameter mm

inch

Approx Weight kg/km

Impedance (Phase-Neutral) /km

/1000ft

Inductance

Reactance

Capacitance

/km

/km

/km

/1000ft

/1000ft

/1000ft

Power Distribution Cable

of cores

Conductor Composition size

8kV SEN(BS), 8kV SEL(BS) (100% Insulation level)

Unarmor

0.6/1kV Control Cable

1 3

0.6/1kV Signal Cable

5kV TEN(BS), 5kV TEL(BS) (133% Insulation level) No. of cores

Conductor Composition size AWG/MCM Nos/AWG

8kV SEN(BS), 8kV SEL(BS) (133% Insulation level)

Unarmor Conductor diameter mm

inch

Insulation thickness mm

inch

Jacket thickness mm

inch

Sheath thickness mm

inch

Overall diameter mm

inch

Armor & Sheath Approx Weight kg/km

Overall diameter mm

inch

Approx Weight kg/km

Conductor Impedance (Phase-Neutral)

Inductance

Reactance

Capacitance

No. of cores

/km

/1000ft

/km

/1000ft

/km

/1000ft

/km

Conductor Composition size AWG/MCM Nos/AWG

/1000ft

Unarmor Conductor diameter mm

inch

Insulation thickness mm

inch

Jacket thickness mm

inch

Sheath thickness mm

inch

Overall diameter mm

inch

Armor & Sheath Approx Weight kg/km

Overall diameter mm

inch

Approx Weight kg/km

Impedance (Phase-Neutral) /km

/1000ft

Inductance

Reactance

Capacitance

/km

/km

/km

/1000ft

/1000ft

/1000ft

Technical Data

1 3

51

High Voltage Power Cable

Conductor

Offshore & Marine Cable

52


High Voltage Power Cable - 5kV, 8kV, 15kV

8kV TEN(BS), 8kV TEL(BS) (100% Insulation level) Conductor

No.

AWG/MCM Nos/AWG

Conductor diameter mm

inch

Insulation thickness mm

inch

Jacket thickness mm

inch

Sheath thickness mm

inch

Overall diameter mm

inch

Conductor

Armor & Sheath Approx Weight kg/km

Overall diameter mm

inch

Approx Weight kg/km

Impedance (Phase-Neutral)

Inductance

Reactance

Capacitance

No. of cores

/km

/1000ft

/km

/1000ft

/km

/1000ft

/km

Conductor Composition size AWG/MCM Nos/AWG

/1000ft

Unarmor Conductor diameter mm

inch

Insulation thickness mm

inch

Jacket thickness mm

inch

Sheath thickness mm

inch

Overall diameter mm

inch

Armor & Sheath Approx Weight kg/km

Overall diameter mm

inch

Approx Weight kg/km

Impedance (Phase-Neutral) /km

/1000ft

Inductance

Reactance

Capacitance

/km

/km

/km

/1000ft

/1000ft

/1000ft

Power Distribution Cable

of cores

Conductor Composition size

15kV SEN(BS), 15kV SEL(BS) (100% Insulation level)

Unarmor

1

0.6/1kV Control Cable

3

0.6/1kV Signal Cable

5kV TEN(BS), 5kV TEL(BS) (133% Insulation level) No. of cores

Conductor Composition size AWG/MCM Nos/AWG

5kV TEN(BS), 5kV TEL(BS) (133% Insulation level)

Unarmor Conductor diameter mm

inch

Insulation thickness mm

inch

Jacket thickness mm

inch

Sheath thickness mm

inch

Overall diameter mm

inch

Armor & Sheath Approx Weight kg/km

Overall diameter mm

inch

Approx Weight kg/km

Conductor Impedance (Phase-Neutral)

Inductance

Reactance

Capacitance

No. of cores

/km

/1000ft

/km

/1000ft

/km

/1000ft

/km

Conductor Composition size AWG/MCM Nos/AWG

/1000ft

Unarmor Conductor diameter mm

inch

Insulation thickness mm

inch

Jacket thickness mm

inch

Sheath thickness mm

inch

Overall diameter mm

inch

Armor & Sheath Approx Weight kg/km

Overall diameter mm

inch

Approx Weight kg/km

Impedance (Phase-Neutral) /km

/1000ft

Inductance

Reactance

Capacitance

/km

/km

/km

/1000ft

/1000ft

/1000ft

High Voltage Power Cable

Conductor

1

Technical Data

3

53

Offshore & Marine Cable

54


High Voltage Power Cable - 5kV, 8kV, 15kV

15kV TEN(BS), 15kV TEL(BS) (100% Insulation level) Conductor

No. of cores

Conductor Composition size AWG/MCM Nos/AWG

Unarmor Conductor diameter mm

inch

Insulation thickness mm

inch

Jacket thickness mm

inch

Sheath thickness mm

inch

Overall diameter mm

inch

Armor & Sheath Approx Weight kg/km

Overall diameter mm

inch

Approx Weight kg/km

Impedance (Phase-Neutral) /km

/1000ft

Inductance

Reactance

Capacitance

/km

/km

/km

/1000ft

/1000ft

/1000ft

Technical Data Technical Data Installation Information 3

15kV TEN(BS), 15kV TEL(BS) (133% Insulation level) Conductor

No. of cores

Conductor Composition size AWG/MCM Nos/AWG

3

55

Unarmor Conductor diameter mm

inch

Insulation thickness mm

inch

Jacket thickness mm

inch

Sheath thickness mm

inch

Overall diameter mm

inch

Armor & Sheath Approx Weight kg/km

Overall diameter mm

inch

Approx Weight kg/km

Impedance (Phase-Neutral) /km

/1000ft

Inductance

Reactance

Capacitance

/km

/km

/km

/1000ft

/1000ft

/1000ft


Technical Data

1. Construction and resistance of flexible stranded conductors Nominal Stranding AWG or cmil

Number of wires

Individual strand dia.(in)

1) TYPE P (FLEXEN 125) Insulated Cables

Maximum dc resistance

mm2

Max conductor dia.(in)

Ohmsper 1000ft at 25°C Bare

Coated

Ohms per 1000ft at 20°C Bare

Coated

Ohms per km at 20°C Bare

Coated

Cable Voltage rating

0 - 2000V

600 -1000V

1001- 2000V

Conductor Size

Insulation resistance

Insulation resistance

Test potentials

AWG or KCM

at 15.6°C [M -km]

at 15.6°C [M -1000ft]

[V]

Power Distribution Cable

Conductor area in circular mils

2. Min. Insulation Resistance & High-voltage AC Test Potentials

0.6/1kV Control Cable 0.6/1kV Signal Cable

1% providing that the maximum conductor diameter and conductor resistance dose not

2) TYPE E Insulated Cables for 5kV - 15kV Shield Conductors

Tolerance for maximum resistance Single conductor

Rmax= value from the Table 1

Multiple conductor One layer of conductors

Rmax= value from the Table 1 x 1.02

More than one layer of conductors

Rmax= value from the Table 1 x 1.03

Pairs or other precabled units

Rmax= value from the Table 1 x 1.04

More than one layer Pairs or other precabled units

Rmax= value from the Table 1 x 1.05

Cable Voltage rating

5kV - 15kV

Conductor Size

insulation resistance constant K

5kV

Test potentials

8kV

AWG or KCM

at 15.6°C [M -1000ft]

[V]

15kV

Technical Data

57

High Voltage Power Cable

Note : The total number of wires should be as specified exceed the values indicated.

Offshore & Marine Cable

58


Technical Data

2) Distribution, Control and Signal Cables(Type X110 @ 45째C ambient)

3) AC Spark test Voltage Cable Voltage rating

0-300 V

301-600/1000 V

Conductor Area

1001/2000 V

Single Core

Two Core

Three Core

Conductor AWG or kcmil

mm2

AWG or MCM

AC spark test voltage(kV)

mm

Power Distribution Cable

X110 2

Circular mils Maximum conductor temperature : 110째C

0.6/1kV Control Cable

* The test is carried out rated 0-2000V manufactured without shield or amor for single conductor cables.

3. Single banked, Maximum Current-Carrying Capacity 1) Distribution,Control and Signal Cables(Type P @ 45째C ambient) Conductor Area

Single Core

Two Core

Three Core

TYPE P mm2

Circular mils

0.6/1kV Signal Cable

AWG or MCM

Maximum conductor temperature : 100째C

High Voltage Power Cable Technical Data

59

Offshore & Marine Cable

60


Technical Data

4. Short circuit current ratings

3) Medium-voltage power cable (Type E @ 45째C ambient) Conductor Area

Single conductor cable

AWG or MCM

mm

8001-15000V shielded

Short circuit currents(kA) 15001-35000V shielded

Circular mils Maximum conductor temperature : 90째C

Nominal crosssectional area (AWG, MCM)

Duration of short circuit in second 0.1

0.2

0.5

Power Distribution Cable

Up to 8kV shielded 2

1.0

0.6/1kV Control Cable 0.6/1kV Signal Cable High Voltage Power Cable

Ampacity adjustment factors for more than 3 conductors in a cable with no load diversity : Percent of values in the above table for three-conductor as adjusted for ambient temperature, if necessary

4) Distribution, Control and Signal Cables(Number of conductors for ambient temperature) Number of conductors

Amapacity adjustment factors for more than 3 conductors in a cable with on load diversity. Percent of values in the above table for three-conductor as adjusted for ambient temperature, if necessary.

Technical Data

5) Correction factors for various cooling temperatures Ambient Temperature

61

Offshore & Marine Cable

62


Installation Information

5. Installation Recommendation 5) Cable Continuty and Grounding

The use of TYPE P insulation type should be restricted to the 70°C(158°F) in shipboard spaces.

All cable should be continuous between terminations , however, splicing is permitted under certain conditions . For cable provided with armor, the armor should be electrically continuous between terminations and should be grounded at each end (multiconductor cables only); except that for final subcircuits, the armor may be grounded at the supply end only.

Power Distribution Cable

1) Maximum ambient temperature

2) Radius of bends 6) Cable Locations r D

3) Cable pulling-in force Care should be taken to prevent damage to insulation or distortion of cable during installation.

Unless unavoidable, cables should not be located behind or embedded in structural heat insulation. Where cables are installed behind paneling, all connections should be readily accessible, and the location of concealed connections should be readily accessible, and the location of concealed connection boxes should be indicated. Cables should preferably not be run through refrigerated cargo spaces.

0.6/1kV Signal Cable

Straight pulling forces should not exceed 0.008 times the tensile strength of the copper cross-sectional area when pulling on the conductors utilizing pulling eyes and bolts. When pulling with a basket-weave grip, maximum pulling tension(per grip) should not exceed 460kg(1000 Ib), or the value calculated above, whichever is greater.

Cable installation should avoid spaces where excessive heat and gases may be encountered such as galleys, boiler rooms and pump rooms, and spaces where cables may be exposed to damage such as cargo spaces and exposed sides of deck houses. Cables should not be located in cargo tanks, ballast tanks, fuel tanks, or water tanks except to supply equipment and instrumentation specifically designed for such locations and whose functions require it to be installed in the tank. Such equipment might include submerged cargo pumps and associated control devices, cargo monitoring instrumentation, and underwater navigation systems.

Cables should not be located in bilges.

The sidewall pressure should not exceed 450 kg/m(300 Ib/ft) of the inside radius of the bend. Cables should not be pulled in freezing conditions. If it is necessary to pull in these conditions, cables should be stored at a temperature above 10°C(50°F) for 24 prior to installation, if the cable has been previously stored in an area under 0°C(32°F) Additional consideration should be given when installing low-smoke cables due to their possible lower tear strength and coefficient of friction.

To avoid an undesirable inductive effect in ac installations, the following precautions should be observed: a) Closed magnetic circuits around single-conductor ac cable should be avoided, and no magnetic material permitted between cables of different phases of a circuit. b) Single-conductor ac cable s should not be located closer than 76mm(3 in) from parallel magnetic material.

7) Cable Protection Cables should be adequately protected where exposed to mechanical damage. Cables should be secured against chafing or displacement due to vibration. Cables in bunkers, and where particularly liable to damage, such as locations in way of cargo ports, hatches, tank tops, and where passing through decks, should be protected by removable metal coverings, angle irons, or other equivalent means. Where cables pass through insulation, they should be protected by a continuous pipe. For wiring entering refrigerated compartments, the pipe should be of heat-insulating material (fiber or phenolic tubing) joined to the bulkhead-stuffing tube, or a section of such material should be inserted between the bulkhead-stuffing tube and the metallic pipe. Where cables a re installed in pipes, the space factor (ratio of the sum of the crosss-sectional areas corresponding to the external diameter of the cables to the internal cross-sectional areas of the pipe) shall not be greater than 0.41, except for two cables, where the space factor shall not exceed 0.31. Pipes shall be so arranged or designed or designed to prevent the accumulation of internal condensation. Technical Data

c) Single conductor ac cable should be supported on insulators. Armor, if used, should be grounded only at approximately the midpoint of the cable run. d) Where single-conductor ac cables penetrate the bulkhead, conductors of each phase of the same circuit should pass through a common nonferrous bulkhead plate to prevent heating of the bulkhead. e) Single-conductor cables in groups should be arranged to minimize their inductive effect. This may be accomplished by the transposition of cables in groups of three (one each phase) to give the effect of triplexed cable. This transposition should be made at intervals of not over 15m(50ft) and need not be made in cable runs of less than 30m(100ft).

63

High Voltage Power Cable

4) Single-Conductor AC Cables

0.6/1kV Control Cable

Armored cables should not be bent to a radius of less than eight times the cable’s diameter. Unarmored cables may not be bent to a radius of less than six times the cable’s diameter.

Offshore & Marine Cable

64


Installation Information

6. Meterial Properties 3) Mechanical Properties of EPR compound (Insulation)

1) Type P Crosslinked Polyolefin Insulation Description

Unit

Description

Requirements

*Application Standard : UL 1072 Unit

Requirements

Power Distribution Cable 0.6/1kV Control Cable

Description

Unit

* Application Standard : Requirements

High Voltage Power Cable

2) Type N Arctic Neoprene Sheath Description

Unit

0.6/1kV Signal Cable

4) Mechanical Properties of Polychloroprene (Neoprene) compound (Sheath) UL 1072

Requirements

Technical Data

65

Offshore & Marine Cable

66


Global Network


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.