HIGH-POWER H E AT P U M P S
Up to 300 kW
NEW GENERATION OF HEAT PUMPS GORENJE 4
COMPLETE RANGE OF NEW GENERATION HIGH-POWER HEAT PUMPS
8
MODERN CONTROL UNIT
HEAT PUMPS AIR-WATER
10
Heat pumps AEROGOR COMPACT W
11
Heat pumps AEROGOR COMPACT EVI W
12
Heat pumps AEROGOR SPLIT AW W
13
Heat pumps AEROGOR SPLIT AW EVI W
14
Heat pumps AEROGOR SPLIT HD W
15
Heat pumps AEROGOR SPLIT HD EVI W
GEOTHERMAL HEAT PUMPS BRINE-WATER AND WATER-WATER
18
Heat pumps AQUAGOR – TERRAGOR W
19
Heat pumps AQUAGOR – TERRAGOR EVI W
20
Table of recommended circulating pumps
21
Operating range
22
Technical specification
3
COMPLETE RANGE O F N E W G E N E R AT I O N H I G H - P OW E R H E AT P U M P S
Model name
4
Outlet water Number of temperature compressors
Model name
Outlet water Number of temperature compressors
Model name
Outlet water Number of temperature compressors
Aerogor Compact 25 – 54 W
60°C
1
Aerogor Split AW 25 – 54 W
60°C
1
Aerogor Split HD 107 W
60°C
2
Aerogor Compact EVI 27 – 56 W
65°C
1
Aerogor Split AW EVI 20 – 55 W
65°C
1
Aerogor Split HD EVI 109 W
65°C
2
Model name
Aerogor Split HD EVI 163 W
Outlet water Number of temperature compressors
65°C
3
Model name
Outlet water Number of temperature compressors
Model name
Outlet water Number of temperature compressors
Aquagor 37 W
60°C
2
Aquagor 50 - 115W
60°C
2
Terragor 28 W
60°C
2
Terragor 38 - 83 W
60°C
2
Aquagor EVI 48 - 126W
65°C
2
Terragor EVI 37 - 98 W
65°C
2
5
MAIN ADVANTAGES O F H E AT P U M P WAT E R H E AT E R S
-20 °C LOW
OPERATING COSTS Efficient operation with high coefficient of performance – excellent COP.
6
HIGH
TEMPERATURE OPERATION The heat pump reaches high temperatures of heating water; therefore, it is also suitable for conventional radiator systems. It is appropriate for both floor heating and radiator heating system (with higher heating water requirements of up to 65 °C).
OPERATION AT
ENVIRONMENT TEMPERATURE
OF DOWN TO
-20°C
The system can successfully operate down to environment temperatures of -20 °C.
EUROPEAN
QUALITY Components by European manufacturers are installed in the heat pump, which guarantees quality and long useful life.
SILENT AND RELIABLE
OPERATION It is allowed by the scroll compressor technology, topclass sound insulation, and ultrasilent axial fan.
ECONOMICAL AND EFFICIENT G O R E N J E H I G H - P OW E R H E AT P U M P S A R E I N T E N D E D F O R L A R G E B U I L D I N G S Economical and efficient heating system with Gorenje heat pumps is a smart choice for both new and existing buildings. High-power heat pumps are intended for larger buildings housing, for example, public institutions (schools, kindergardens, banks etc.) or smaller to medium-sized industrial and commercial premises (offices, sports halls, restaurants etc.). They are suitable for both low-temperature heating systems (new buildings with floor heating or low-temperature radiators) and buildings with high-temperature heating systems with conventional radiators (refurbished or older buildings) as they can heat the water to a temperature of 55 to 65 °C.
We offer two types of high-power geothermal heat pumps:
Characteristics of high-power heat pumps:
• Aquagor W water/water heat pumps with heating capacity ranging from 37 to 115 kW. • Terragor W brine/water heat pumps with heating capacity ranging from 28 to 83 kW.
• Geothermal heat pumps operate in two levels/cycles: Two compressors operate in a cascade system to allow the adjustment of heating power to the heating requirements of the building in different periods of the heating season.
Aquagor EVI W water/water heat pump with heating capacity ranging from 48 to 126 kW. Terragor EVI W brine/water heat pumps with heating capacity ranging from 37 to 98 kW. • Moreover, we offer different types of air-water heat pumps with wide range of heating capacity (20 - 163 kW): • Aerogor Compact 25 - 54 W • Aerogor Compact EVI 27 - 56 W • Aerogor Split AW 25 - 54 W • Aerogor Split AW EVI 20 - 55 W • Aerogor Split HD 107 W • Aerogor Split HD EVI 109/163 W
• High-temperature heat pumps can heat the water to a temperature of 65 °C: • Aerogor Compact EVI W / Split AW EVI W / Split HD EVI W • Terragor EVI W • Aquagor EVI W
• Geothermal heat pumps (brine-water / water- water) allows passive cooling mode in combination with preheat exchanger. Active cooling mode - optionally (on the request).
ACTIVE/PASIVE COOLING
HEATING MODE
DOMESTIC HOT WATER
• Low-temperature heat pumps can heat the water to a temperature of 55 to 60 °C: • Aerogor Compact W / Split AW W / Split HD W • Terragor W • Aquagor W The heat pumps can operate
• Complete range or air-water heat pumps allows active cooling mode during the hot summer months (serial integrated 4- way reversible valve and electronic expanison valve enables this procces).
ACTIVE COOLING
HEATING MODE
in cascade system:
60/65°C
DOMESTIC HOT WATER
7
MODERN CONTROL UNIT Modern control unit allows different settings for heating, cooling, and domestic hot water heating. The regulation is weather-dependent. The control unit regulates the heat pump and heating system operation according to the outdoor environment temperature and the desired indoor temperature in the user’s home. Owing to a special algorithm, the heat pump only generates as much heat as required by the heating system, in any given moment.
Basic regulation
Easy control
Basic regulation of RVS 61 supports two independent heating circuits – one direct and one mixing circuit. For each circuit, the heating curve is set independently. Basic regulation of RVS 21 supports regulation of one direct heating circuit and DHW circuit. Basic regulation (RVS 61 and RVS 21) also supports heating of sanitary water with anti-Legionella program, as well as alternative sources such as solar panels or wood-fired furnaces. It also allows hasslefree regulation of additional sources such as a heating oil or gas burner. Electronic controls are universal for all types of heat pumps and heating methods. In case of major systems, upgrading the basic regulation unit is quite straightforward. In most cases, heating circuit regulation depends on the exterior temperature. The heating curve depends on the characteristics of the building being heated, which is the only warranty that the heat pump, regardless of the outdoor temperature, will always heat the water to the lowest acceptable temperature. The level of temperature thus defines the efficiency of the heating system. The lower the heating temperature, the higher the Coefficient of Performance.
Menu navigation is plain and simple. Each screen is indicated with a consecutive number so that the user is aware at all times which page of the menu is currently open. Commands re indicated with appropriate wording. The unit can be controlled via user keyboard on the heat pump, or through an additional room control unit. Basic functions are available through keys on the control unit and heating system temperature is easily set with a rotating dial located in the middle of the control unit. For advanced users, controls can also be routed hrough interfaces to a personal computer or even to an intelligent home system.
RVS 21 Aerogor Compact 25 – 54 W
Yes
Aerogor Compact EVI 27 – 56 W
Yes Yes
Aerogor Split AW EVI 25 – 55 W
Yes Yes
Aerogor Split HD EVI 109 W
Yes
Aerogor Split HD EVI 163 W
Yes
Control of direct HC*:
Yes
Control of DHW circuit:
Yes
Control active/passive cooling mode:
Yes
Control of mixing HC*:
Yes
Control of direct pump HC*:
Yes
Solar system control:
Yes
*HC = heating circuit
INSTALLED HP CONTROLLER SIEMENS RVS 21
Aerogor Split AW 20 – 54 W
Aerogor Split HD 107 W
8
RVS 61
INSTALLED HP CONTROLLER SIEMENS RVS 61
Aquagor – Terragor W
Yes
Aquagor – Terragor EVI W
Yes
Control of direct HC*:
Yes
Control of DHW circuit:
Yes
Active cooling mode:
Yes
Control of mixed HC*:
with EXM**
Control of direct pump HC*:
with EXM**
Solar system control:
with EXM**
*HC = heating circuit **EXM = Extension module
Electronic control enable regulation of different heating systems
Smart Web - remote control
Large buildings in lot of cases need for different parts of the building – different temperature regulation. Control units of heat pumps Gorenje enable regulation of different heating/cooling zones. Here are solutions for some cases.
The Smart Web application allows you to monitor your heat pump operation regardless of where you are. An internet connection can be used to connect the heat pump controllers to your personal computer or your cell phone. Thus, the system allows you to monitor the settings, to keep up to date with the device operating status, and to receive a warning in case of any failures. This makes remote control of your heating system convenient as well as cost and energy-effective due to constant control over equipment operation.
Regulation of different heating zones with control unit Siemens RVS 21 CASE 1: 3 HEATING ZONES WITH 3 MIXING HEATING CIRCUITS: 1st mixing heating circuit: • Extension module Siemens AVS75.390/109 • 1 x NTC temperature sensor
Regulation of different heating zones with control unit Siemens RVS 61
2nd mixing heating circuit:
CASE 1: 3 HEATING ZONES WITH 3 MIXING HEATING CIRCUITS:
• Extension module Siemens AVS75.390/109
1st mixing heating circuit:
• 1 x NTC temperature sensor
• controlled by Basic control unit RVS 61
3rd mixing heating circuit:
2nd mixing heating circuit:
• Extension module RVS46.530/101
• Extension module Siemens AVS75.390/109
• 1 x NTC temperature sensor
• 1 x NTC temperature sensor
• Room unit advanced/cooling/wired QAA75.611/701
3rd mixing heating circuit:
CASE 2: 3 HEATING ZONES WITH 1 DIRECT AND 2 MIXING CIRCUITS:
• Extension module RVS46.530/101
1st direct heating circuit:
• 1 x NTC temperature sensor
• controlled by Basic control unit RVS 21
• Room unit advanced/cooling/wired QAA75.611/701
2nd mixixng heating circuit:
CASE 2: 3 HEATING ZONES WITH 1 DIRECT AND 2 MIXING CIRCUITS:
• Extension module Siemens AVS75.390/109
1st direct heating circuit:
• 1 x NTC temperature sensor
• controlled by Basic control unit RVS 61
3rd direct heating circuit:
1st mixing heating circuit:
• Extension module Siemens AVS75.390/109
• controlled by Basic control unit RVS 61
• 1 x NTC temperature sensor
2nd mixing heating circuit:
CASE 3: 3 ZONES WITH 3 DIRECT HEATING CIRCUITS:
• Extension module AVS75.390/109
1st direct heating circuit:
• 1 x NTC Temperature sensor
• controlled by Basic control unit RVS 21
CASE 3: 3 ZONES WITH 3 DIRECT HEATING CIRCUITS:
2nd direct heating circuit:
1st and 2nd direct heating circuit:
• Extension module Siemens AVS75.390/10
• controlled by Basic control unit RVS 61
• 1 x NTC temperature sensor
3rd direct heating circuit:
3nd direct heating circuit:
• Extension module Siemens AVS75.390/109
• Extension module Siemens AVS75.390/109
• 1 x NTC temperature sensor
• 1 x NTC temperature sensor
Heat pump electronic control unit
USB
Ethernet
OZW 164
Alarm email Internet
9
HEAT PUMPS AEROGOR COMPACT W A I R – WAT E R A E R O G O R C O M PAC T 2 5 – 5 4 W The main components and temperature sensors Compact outdoor unit
HIGH
TEMPERATURE OPERATION
Indoor unit Basic: DisplayBox W • Display of control unit (HMI) • Heating/Cooling mode Advanced: ControlBox W • main power switch • display from control unit • 1 x extension module AVS75.370 • Heating/Cooling/DHW mode
LEGEND Q9: circulating pump on the secondary side (condenser) Type: Grundfos Alpha/Magna Efficiency class: A B84: temperature sensor 1 of source side (evaporator) B91: temperature sensor 2 of source side (evaporator) K1/E11: compressor 1 Type: Copeland scroll ZH High efficiency and quite scroll technology Long life period B21: water outlet temperature sensor (condenser) B71: water inlet temperature sensor (condenser) Y22: 4-way reversible valve K19/E14: Fan motor
10
MAIN ADVANTAGES Max. Outlet water temperature: 60°C (55°C up to ambient temperature -15°C) High efficiency Scroll ZH compressor (1 X) SWEP heat exchanger Tilting compact electro box with safety elements and control system 1 x EEV (electonic expansion valve) + 1 x TEV (thermo expansion valve) Special V form of evaporator Evaporator heat exchanger frost free in the lower part – APS System Multi layer sound insulation Safety elements for protection: • Flow switch build-in • Pressure switch heating water (0,7 bar) • Soft start module for compressor (Danfoss) • Motor protection for compressor • Crankcase heater for compressor • Motor protection for fan • Phase direction control • High tariff lock • Compressor over clock protection
Operating modes HEATING MODE DOMESTIC HOT WATER ACTIVE COOLING ACCESSORIES LIST • 10 meter LAN cable with RJ45 connectors • 1 x Outdoor temperature sensor for weather-dependent regulation • 2 x cable temperature (+5 to 95°C) sensors in the package
HEAT PUMPS AEROGOR COMPACT EVI W A I R – WAT E R A E R O G O R C O M PAC T E V I 2 7 – 5 6 W The main components and temperature sensors Compact outdoor unit
HIGH
TEMPERATURE OPERATION
Indoor unit Basic: DisplayBox W • Display of control unit (HMI) • Heating/Cooling mode Advanced: ControlBox W • main power switch • display from control unit • 1 x extension module AVS75.370 • Heating/Cooling/DHW mode
LEGEND Q9: circulating pump on the secondary side (condenser) Type: Grundfos Alpha/Magna Efficiency class: A B84: temperature sensor 1 of source side (evaporator) B91: temperature sensor 2 of source side (evaporator) K1/E11: compressor 1 Type: Copeland scroll ZH EVI Extreme good performances Long life period B21: water outlet temperature sensor (condenser) B71: water inlet temperature sensor (condenser) Y22: 4-way reversible valve K19/E14: Fan motor
MAIN ADVANTAGES Max. Outlet water temperature: 65°C (up to ambient temperature -20°C) High efficiency Scroll EVI compressor (1 X) SWEP heat exchanger Tilting compact electro box with safety elements and control system 1 x EEV (electonic expansion valve) + 1 x TEV (thermo expansion valve) Special V form of evaporator Evaporator heat exchanger frost free in the lower part – APS System Multi layer sound insulation Serial integrated circulating pump Safety elements for protection: • Flow switch build-in • Pressure switch heating water (0,7 bar) • Soft start module for compressor (Danfoss) • Motor protection for compressor • Crankcase heater for compressor • Motor protection for fan • Phase direction control • High tariff lock • Compressor over clock protection
Operating modes HEATING MODE DOMESTIC HOT WATER ACTIVE COOLING ACCESSORIES LIST • 10 meter LAN cable with RJ45 connectors • 1 x Outdoor temperature sensor for weather-dependent regulation • 2 x cable temperature (+5 to 95°C) sensors in the package
11
HEAT PUMPS AEROGOR SPLIT AW W A I R – WAT E R A E R O G O R S P L I T AW 2 5 – 5 4 W The main components and temperature sensors Compact outdoor unit
LEGEND Q9: circulating pump on the secondary side (condenser) Type: Grundfos Alpha/Magna Efficiency class: A B84: temperature sensor 1 of source side (evaporator) B91: temperature sensor 2 of source side (evaporator) K1/E11: compressor 1 Type: Copeland scroll ZH High efficiency and quite scroll technology Long life period B21: water outlet temperature sensor (condenser) B71: water inlet temperature sensor (condenser) Y22: 4-way reversible valve K19/E14: Fan motor
12
HIGH
TEMPERATURE OPERATION
Indoor unit
MAIN ADVANTAGES Max. Outlet water temperature: 60°C (55°C up to ambient temperature -15°C) High efficiency Scroll ZH compressor (1 X) SWEP heat exchanger Tilting compact electro box with safety elements and control system 1 x EEV (electonic expansion valve) + 1 x TEV (thermo expansion valve) Special V form of evaporator Evaporator heat exchanger frost free in the lower part – APS System Multi layer sound insulation Safety elements for protection: • Flow switch build-in • Pressure switch heating water (0,7 bar) • Soft start module for compressor (Danfoss) • Motor protection for compressor • Crankcase heater for compressor • Motor protection for fan • Phase direction control • High tariff lock • Compressor over clock protection
Operating modes HEATING MODE DOMESTIC HOT WATER ACTIVE COOLING ACCESSORIES LIST • 1 x Outdoor temperature sensor for weather-dependent regulation • 2 x cable temperature (+5 to 95°C) sensors in the package
HEAT PUMPS AEROGOR SPLIT AW EVI W A I R – WAT E R A E R O G O R S P L I T AW E V I 2 0 – 5 5 W The main components and temperature sensors Compact outdoor unit
HIGH
TEMPERATURE OPERATION
Indoor unit
LEGEND Q9: circulating pump on the secondary side (condenser) Type: Grundfos Alpha/Magna Efficiency class: A B84: temperature sensor 1 of source side (evaporator) B91: temperature sensor 2 of source side (evaporator) K1/E11: compressor 1 Type: Copeland scroll ZH EVI Extreme good performances Long life period B21: water outlet temperature sensor (condenser) B71: water inlet temperature sensor (condenser) Y22: 4-way reversible valve K19/E14: Fan motor
MAIN ADVANTAGES Max. Outlet water temperature: 65°C (up to ambient temperature -20°C) High efficiency Scroll EVI compressor (1 X) SWEP heat exchanger Tilting compact electro box with safety elements and control system 1 x EEV (electonic expansion valve) + 1 x TEV (thermo expansion valve) Special V form of evaporator Evaporator heat exchanger frost free in the lower part – APS System Multi layer sound insulation Serial integrated circulating pump Safety elements for protection: • Flow switch build-in • Pressure switch heating water (0,7 bar) • Soft start module for compressor (Danfoss) • Motor protection for compressor • Crankcase heater for compressor • Motor protection for fan • Phase direction control • High tariff lock • Compressor over clock protection
Operating modes HEATING MODE DOMESTIC HOT WATER ACTIVE COOLING ACCESSORIES LIST • 1 x Outdoor temperature sensor for weather-dependent regulation • 2 x cable temperature (+5 to 95°C) sensors in the package
13
HEAT PUMPS AEROGOR SPLIT HD W A I R – WAT E R A E R O G O R S P L I T H D 1 07 W The main components and temperature sensors Outdoor unit 1
Outdoor unit 2
LEGEND Q9: circulating pump on the secondary side (condenser) Type: Grundfos Alpha/Magna Efficiency class: A B84: temperature sensor 1 of source side (evaporator) B91: temperature sensor 2 of source side (evaporator) K1/E11: compressor 1 and 2 Type: Copeland scroll ZH High efficiency and quite scroll technology Long life period B21: water outlet temperature sensor (condenser) B71: water inlet temperature sensor (condenser) Y22: 4-way reversible valve K19/E14: Fan motor
14
HIGH
TEMPERATURE OPERATION
Indoor unit (2 x compressors)
MAIN ADVANTAGES Max. Outlet water temperature: 60°C (up to ambient temperature -15°C) 2 X High efficiency Scroll ZH compressor SWEP heat exchanger Tilting compact electro box with safety elements and control system 2 x EEV (electonic expansion valve) + 2 x TEV (thermo expansion valve) Special V form of evaporator Evaporator heat exchanger frost free in the lower part – APS System Multi layer sound insulation Without serial integrated circulating pump Safety elements for protection: • Flow switch build-in • Pressure switch heating water (0,7 bar) • Soft start module for compressor (Danfoss) • Motor protection for compressor • Crankcase heater for compressor • Motor protection for fan • Phase direction control • High tariff lock • Compressor over clock protection
Operating modes HEATING MODE DOMESTIC HOT WATER ACTIVE COOLING ACCESSORIES LIST • 1 x Outdoor temperature sensor for weather-dependent regulation • 2 x cable temperature (+5 to 95°C) sensors in the package
HEAT PUMPS AEROGOR SPLIT HD EVI W A I R – WAT E R A E R O G O R S P L I T H D E V I 1 0 9 W The main components and temperature sensors Outdoor unit 1
Outdoor unit 2
LEGEND Q9: circulating pump on the secondary side (condenser) Type: Grundfos Alpha/Magna Efficiency class: A B84: temperature sensor 1 of source side (evaporator) B91: temperature sensor 2 of source side (evaporator) K1/E11: compressor 1 and 2 Type: Copeland scroll ZH EVI Extreme good performances Long life period B21: water outlet temperature sensor (condenser) B71: water inlet temperature sensor (condenser) Y22: 4-way reversible valve K19/E14: Fan motor
HIGH
TEMPERATURE OPERATION
Indoor unit (2 x compressors)
MAIN ADVANTAGES Max. Outlet water temperature: 65°C (up to ambient temperature -20°C) 2 X High efficiency Scroll EVI compressor SWEP heat exchanger Tilting compact electro box with safety elements and control system 2 x EEV (electonic expansion valve) + 2 x TEV (thermo expansion valve) Special V form of evaporator Evaporator heat exchanger frost free in the lower part – APS System Multi layer sound insulation Without serial integrated circulating pump Safety elements for protection: • Flow switch build-in • Pressure switch heating water (0,7 bar) • Soft start module for compressor (Danfoss) • Motor protection for compressor • Crankcase heater for compressor • Motor protection for fan • Phase direction control • High tariff lock • Compressor over clock protection
Operating modes HEATING MODE DOMESTIC HOT WATER ACTIVE COOLING ACCESSORIES LIST • 1 x Outdoor temperature sensor for weather-dependent regulation • 2 x cable temperature (+5 to 95°C) sensors in the package
15
HEAT PUMPS AEROGOR SPLIT HD EVI W A I R – WAT E R A E R O G O R S P L I T H D E V I 1 6 3 W The main components and temperature sensors Outdoor unit 1
Outdoor unit 2
LEGEND Q9: circulating pump on the secondary side (condenser) Type: Grundfos Alpha/Magna Efficiency class: A B84: temperature sensor 1 of source side (evaporator) B91: temperature sensor 2 of source side (evaporator) K1/E11: compressors 1, 2, 3 Type: Copeland scroll ZH EVI Extreme good performances Long life period B21: water outlet temperature sensor (condenser) B71: water inlet temperature sensor (condenser) Y22: 4-way reversible valve K19/E14: Fan motor
16
Outdoor unit 3
HIGH
TEMPERATURE OPERATION
Indoor unit (3 x compressors)
MAIN ADVANTAGES Max. Outlet water temperature: 65°C (up to ambient temperature -20°C) 3 X High efficiency Scroll EVI compressor SWEP heat exchanger Tilting compact electro box with safety elements and control system 3 x EEV (electonic expansion valve) + 3 x TEV (thermo expansion valve) Special V form of evaporator Evaporator heat exchanger frost free in the lower part – APS System Multi layer sound insulation Without serial integrated circulating pump Safety elements for protection: • Flow switch build-in • Pressure switch heating water (0,7 bar) • Soft start module for compressor (Danfoss) • Motor protection for compressor • Crankcase heater for compressor • Motor protection for fan • Phase direction control • High tariff lock • Compressor over clock protection
Operating modes HEATING MODE DOMESTIC HOT WATER ACTIVE COOLING ACCESSORIES LIST • 1 x Outdoor temperature sensor for weather-dependent regulation • 2 x cable temperature (+5 to 95°C) sensors in the package
17
GEOTHERMAL HEAT PUMPS BRINE-WATER AND WATER-WATER H E AT P U M P S AQ UAG O R – T E R R AG O R W The main components and temperature sensors HIGH
Geothermal heat pumps operate in two levels/cycles:
TEMPERATURE OPERATION
Two compressors operate in a cascade system to allow the adjustment of heating power to the heating requirements of the building in different periods of the heating season.
ACCESSORIES LIST • 1 x Outdoor temperature sensor for weather-dependent regulation • 2 x cable temperature (+5 to 95°C) sensors in the package
MAIN ADVANTAGES Max. Outlet water temperature: 60°C Passive cooling mode • Reverse active cooling – optional 2 X High efficiency Scroll ZH compressor SWEP heat exchanger Tilting compact electro box with safety elements and control system
LEGEND
1 x EEV (electonic expansion valve) • Large surface condenser and evaporator plate heat exchanger • Robust and solid refrigeration cycle designed for highest stability and long term high performance Multi layer sound insulation
Q8: circulating pump on source side Q9: circulating pump on the secondary side (condenser) B91: inlet temperature sensor of source side (evaporator) B92: outlet temperature sensor of source side (evaporator) K1 / E11: compressor 1 K2 / E12: compressor 2 B21: water outlet temperature sensor (condenser) B71: water inlet temperature sensor (condenser) 18
Without serial integrated circulating pump Safety elements for protection: • Flow switch build-in • Pressure switch heating water (0,7 bar) • Soft start module for compressor (Danfoss) • Motor protection for compressor • Crankcase heater for compressor • Motor protection for fan • Phase direction control • High tariff lock • Compressor over clock protection
Operating modes HEATING MODE DOMESTIC HOT WATER ACTIVE/PASIVE COOLING
H E AT P U M P S AQ UAG O R – T E R R AG O R E V I W The main components and temperature sensors HIGH
Geothermal heat pumps operate in two levels/cycles:
TEMPERATURE OPERATION
Two compressors operate in a cascade system to allow the adjustment of heating power to the heating requirements of the building in different periods of the heating season.
ACCESSORIES LIST • 1 x Outdoor temperature sensor for weather-dependent regulation • 2 x cable temperature (+5 to 95°C) sensors in the package
MAIN ADVANTAGES Max. Outlet water temperature: 65°C Passive cooling mode • Reverse active cooling – optional 2 X High efficiency Scroll ZH compressor SWEP heat exchanger Tilting compact electro box with safety elements and control system
LEGEND
2 x EEV (electonic expansion valve) • Large surface condenser and evaporator plate heat exchanger • Robust and solid refrigeration cycle designed for highest stability and long term high performance Multi layer sound insulation
Q8: circulating pump on source side Q9: circulating pump on the secondary side (condenser) B91: inlet temperature sensor of source side (evaporator) B92: outlet temperature sensor of source side (evaporator) K1 / E11: compressor 1 K2 / E12: compressor 2 B21: water outlet temperature sensor (condenser) B71: water inlet temperature sensor (condenser)
Without serial integrated circulating pump Safety elements for protection: • Flow switch build-in • Pressure switch heating water (0,7 bar) • Soft start module for compressor (Danfoss) • Motor protection for compressor • Crankcase heater for compressor • Motor protection for fan • Phase direction control • High tariff lock • Compressor over clock protection
Operating modes HEATING MODE DOMESTIC HOT WATER ACTIVE/PASIVE COOLING 19
OPERATING RANGE F O R A E R O G O R C O M PAC T W A N D A E R O G O R C O M PAC T E V I W OPERATING RANGE OF: AEROGOR COMPACT EVI W AEROGOR SPLIT HD EVI W OUTLET WATER TEMPERATURE [째C]
70 65 60 55 50 45 40 35 30 25 -25
-20
-15
-10
-5
0
5
10
OUTSIDE AMBIENT TEMPERATURE [째C]
15
20
25
Optimum
30
35
40
45
40
45
Maximum
OPERATING RANGE OF: AEROGOR COMPACT W A ER OGOR SPL I T AW W, A ER OGOR SPL I T HD W OUTLET WATER TEMPERATURE [째C]
70 65 60 55 50 45 40 35 30 25 -25
-20
-15
-10
-5
0
5
10
15
20
OUTSIDE AMBIENT TEMPERATURE [째C]
20
25
30
35
OPERATING RANGE F O R AQ UAG O R – T E R R AG O R W A N D AQ UAG O R – T E R R AG O R E V I W OPERATING RANGE TERRAGOR EVI W
70
70
65
65
OUTLET WATER TEMPERATURE [°C]
OUTLET WATER TEMPERATURE [°C]
OPERATING RANGE TERRAGOR W
60 55 50 45 40 35 30 25
55 50 45 40 35 30 25
-10
-5
0
5
10
15
20
25
30
-10
-5
0
5
10
15
20
25
SOURCE (BRINE) TEMPERATURE [°C]
SOURCE (BRINE) TEMPERATURE [°C]
OPERATING RANGE AQUAGOR W
OPERATING RANGE AQUAGOR EVI W
70
70
65
65
OUTLET WATER TEMPERATURE [°C]
OUTLET WATER TEMPERATURE [°C]
60
60 55 50 45 40 35 30 25
30
60 55 50 45 40 35 30 25
-10
-5
0
5
10
15
SOURCE (WATER) TEMPERATURE [°C]
20
25
30
-10
-5
0
5
10
15
20
25
30
SOURCE (WATER) TEMPERATURE [°C]
21
TABLE OF RECOMMENDED CIRCULATING PUMPS F O R AQ UAG O R – T E R R AG O R W A N D AQ UAG O R – T E R R AG O R E V I W
22
Model name
Primary side – source side (brine)*
Secondary side – heating side
Terragor 28 W Aquagor 37 W
WILO Stratos 40/1-8
WILO Stratos 30/1-8
Terragor 38 W Aquagor 50 W
WILO Stratos 50/1-8
WILO Stratos 50/1-8
Terragor 43 W Aquagor 59 W
WILO Stratos 50/1-8
WILO Stratos 50/1-8
Terragor 52 W Aquagor 67 W
WILO Stratos 50/1-9
WILO Stratos 50/1-8
Terragor 56 W Aquagor 78 W
WILO Stratos 50/1-9
WILO Stratos 50/1-8
Terragor 65 W Aquagor 89 W
WILO Stratos 65/1-12
WILO Stratos 65/1-12
Terragor 70 W Aquagor 100 W
WILO Stratos 80/1-12
WILO Stratos 80/1-12
Terragor 83 W Aquagor 115 W
WILO Stratos 80/1-12
WILO Stratos 80/1-12
Terragor EVI 67 W Aquagor EVI 87 W
WILO Stratos 65/1-12
WILO Stratos 65/1-12
Terragor EVI 81 W Aquagor EVI 105 W
WILO Stratos 80/1-12
WILO Stratos 80/1-12
Terragor EVI 98 W Aquagor EVI 126 W
WILO Stratos 80/1-12
WILO Stratos 80/1-12
* Valid only for systems brine-water. On the primary (source) side of heat pump waterwater must be built-in submersible pump for the underground water. Type of submersible pump is depend on the deepness of borehole of and the distance (pipe length) from borehole to the heat pump.
AEROGOR SPLIT HD W and SPLIT EVI HD W
Split system air / water : outdoor unit + indoor unit
Model name Operating modes ErP energy class (LT/HT) Connection between outdoor and indoor unit Heating capacity A7/W35 COP A7/W35 Heating capacity A7/W45 COP A7/W45 Heating capacity A7/W55 COP A7/W55 Heating capacity A7/W65 COP A7/W65 Heating capacity A2/W35 COP A2/W35 Heating capacity A2/W45 COP A2/W45 Heating capacity A2/W55 COP A2/W55 Heating capacity A2/W65 COP A2/W65 Heating capacity A-2/W35 COP A-2/W35 Heating capacity A-7/W35 COP A-7/W35 Heating capacity A-15/W35 COP A-15/W35 Maximum outlet water temperature Operating range Active cooling Cooling capacity - reversible operation A35/W12 Power input - reversible operation A35/W12 ERR Neto weight - outdoor unit Neto weight - indoor unit Dimensions of outdoor unit (W x D x H) Dimensions of indoor unit (W x D x H) Voltage Noise emissions [5m] - indoor unit Noise emissions [8m] - outdoor unit Connecting dimensions – primary side Connecting dimensions – secondary side Type of screw thread - outdoor unit Air flow - primary side Nominal water flow - secondary side Pressure drop - primary side Pressure drop - secondary side Recommended temperature difference (flow / return) Main connection cable – dimension Power connection (indoor - outdoor unit) Electrical connection cable between indoor - outdoor unit [sheathed] Fuse / Type Current – nominal Current – maximal Softstart Starting current Type of refrigerant Volume of refrigerant Type of expansion valve Type of compressor Number of compressors Circulating pumps - return flow Fan type Back-up electrical flow heater 3-way diverting valve Serial integrated controller Control of mixing heating cirquit Control of direct heating cirquit Solar system control ModBus WebControl Option for cascade system *LT/HT = low temperature / high or medium temperature systems.
kW / kW / kW / kW / kW / kW / kW / kW / kW / kW / kW / °C °C / kW kW / kg kg mm mm V/Hz dB dB mm ” / 3 m /h m3/h kPa kPa K mm2 mm2 mm2 A A A / A / kg / / / / / / / / / / / / / /
Aerogor Split HD 107 W 2 x outdoor unit
Aerogor Split HD EVI 109 W 2 x outdoor unit
Aerogor Split HD EVI 163 W 3 x outdoor unit
Heating / Cooling / DHW A++/A++ Refrigerant pipe connection 106,60 4,77 102,37 3,79 96,66 3,00 / / 86,73 3,70 83,37 3,02 79,21 2,39 / / 72,88 3,32 61,22 3,06 49,81 2,45 60 -20°C to +40°C yes 68,4 31 2,2 410 2 x 185 1050 x 1700 x 1530 1233 x 1371 x 1300 3 x 400 / 50 Hz 59 69 2 x (22 mm / 35 mm) 1 1/2” inner 2 x 14.067 2 x 5,1 2 x 0,061 max 20 7 5 x 25 mm2 2 x 3 x 1,5 mm2 2 x 10 x 0,75 mm2 63 A / C 2 x 18 2 x 36,3 2 x MCD201 2 x 47,52 R407C 2 x 12,5 EEV Copeland SCROLL ZH 2 no Ziehl Abegg FN Owlet no no Siemens RVS 21 with extension module with extension module with extension module with extension module with WebServer module Yes (with LPB module)
Heating / Cooling / DHW A++/A++ Refrigerant pipe connection 109,04 4,91 110,31 4,04 112,34 3,31 112,76 2,72 93,46 3,80 94,14 3,12 95,24 2,56 96,25 2,10 86,49 3,44 80,59 3,09 67,05 2,59 65 -20°C to +40°C yes 73,6 33,4 2,2 450 2 x 185 1050 x 1700 x 1530 1233 x 1371 x 1300 3 x 400 / 50 Hz 59 69 2 x (22 mm / 35 mm) 1 1/2” inner 2 x 14.067 2 x 5,7 2 x 0,061 max 20 7 5 x 25 mm2 2 x 3 x 1,5 mm2 2 x 10 x 0,75 mm2 80 A / C 2 x 20,8 2 x 35,9 2 x MCD201 2 x 54,91 R407C 2 x 14 EEV Copeland SCROLL EVI 2 no Ziehl Abegg FN Owlet no no Siemens RVS 21 with extension module with extension module with extension module with extension module with WebServer module Yes (with LPB module)
Heating / Cooling / DHW A++/A++ Refrigerant pipe connection 163,33 4,91 165,24 4,04 168,28 3,31 168,91 2,72 140,00 3,80 141,02 3,12 142,66 2,56 144,18 2,10 129,56 3,44 120,72 3,09 100,43 2,59 65 -20°C to +40°C yes 110,4 50,1 2,2 740 3 x 185 1050 x 1700 x 1530 1233 x 1371 x 1300 3 x 400 / 50 Hz 61 73 3 x (22 mm / 35 mm) 1 1/2” inner 3 x 14.067 3 x 5,7 3 x 0,061 max 20 7 5x25 mm2 3 x 3 x 1,5 mm2 3 x 10 x 0,75 mm2 100 A / C 3 x 20,8 3 x 35,9 3 x MCD201 3 x 54,91 R407C 3 x 14 EEV Copeland SCROLL EVI 3 no Ziehl Abegg FN Owlet no no Siemens RVS 21 with extension module with extension module with extension module with extension module with WebServer module Yes (with LPB module)
23
AEROGOR COMPACT W + DisplayBox W / ControlBox W
System air / water - Compact outdoor unit 24
Model name
Basic solution:
Operating modes Model name
Advanced solution:
Operating modes ErP energy class (LT/HT) Connection between outdoor unit and heating system Heating capacity A7/W35 COP A7/W35 Heating capacity A7/W45 COP A7/W45 Heating capacity A7/W55 COP A7/W55 Heating capacity A7/W65 COP A7/W65 Heating capacity A2/W35 COP A2/W35 Heating capacity A2/W45 COP A2/W45 Heating capacity A2/W55 COP A2/W55 Heating capacity A2/W65 COP A2/W65 Heating capacity A-2/W35 COP A-2/W35 Heating capacity A-7/W35 COP A-7/W35 Heating capacity A-15/W35 COP A-15/W35 Maximum outlet water temperature Operating range Active cooling Cooling capacity - reversible operation A35/W12 Power input - reversible operation A35/W12 ERR Neto weight - outdoor unit Neto weight - indoor unit Dimensions of outdoor unit (W x D x H) Dimensions of indoor unit (W x D x H) Voltage Noise emissions [5m] - indoor unit Noise emissions [8m] - outdoor unit Connecting dimensions – secondary side Type of screw thread - outdoor unit Air flow - primary side Nominal water flow - secondary side Pressure drop - primary side Pressure drop - secondary side Recommended temperature difference (flow / return) Main connection cable – dimension Power connection (indoor - outdoor unit) Electrical connection cable between indoor - outdoor unit [sheathed] Fuse / Type Current – nominal Current – maximal Softstart Starting current Type of refrigerant Volume of refrigerant Type of expansion valve Type of compressor Number of compressors Circulating pumps - return flow Fan type Back-up electrical flow heater 3-way diverting valve Serial integrated controller Control of mixing heating cirquit Control of direct heating cirquit Solar system control ModBus WebControl Option for cascade system
*LT/HT = low temperature / high or medium temperature systems.
kW / kW / kW / kW / kW / kW / kW / kW / kW / kW / kW / °C °C / kW kW / kg kg mm mm V/Hz dB dB ” / m3/h m3/h kPa kPa K mm2 mm2 mm2 A A A / A / kg / / / / / / / / / / / / / /
Aerogor Compact 25 W + DisplayBox W Heating / Cooling Aerogor Compact 25 W + ControlBox W Heating / Cooling / DHW A++/A++ water pipe connection 25,31 4,64 24,30 3,69 22,95 2,92 / / 20,59 3,60 19,79 2,93 18,81 2,33 / / 17,30 3,23 14,53 2,98 11,82 2,39 60 -20°C to +40°C yes 16,50 7,10 2,3 290 27 1345 x 930 x 943 535 x 350 x 590 3 x 400 / 50 Hz 0 58 1 1/4 inner 4959 3,20 0,05 max 20 5 5 x 6 mm2 5 x 6 mm2 UTP & 5 x 0,75 mm2 32 A / C 11,60 27,90 MCI 25 30,62 R407C 7,00 EEV Copeland SCROLL ZH 1 yes Ziehl Abegg FN Owlet no no Siemens RVS 21 with extension module yes with extension module with extension module with WebServer module Yes (with LPB module)
Aerogor Compact 36 W + DisplayBox W Heating / Cooling Aerogor Compact 36 W + ControlBox W Heating / Cooling / DHW A++/A++ water pipe connection 35,77 4,77 34,35 3,79 32,43 3,00 / / 29,10 3,70 27,97 3,70 26,58 2,39 / / 24,45 3,32 20,45 3,06 16,71 2,45 60 -20°C to +40°C yes 23,30 10,10 2,3 350 27 1776 x 1371 x 1246 535 x 350 x 590 3 x 400 / 50 Hz 0 61 1 1/2 inner 5800 4,60 0,057 max 20 5 5 x 6 mm2 5 x 6 mm2 UTP & 5 x 0,75 mm2 25 A / C 11,80 23,90 MCI 25 31,15 R407C 7,30 EEV Copeland SCROLL ZH 1 yes Ziehl Abegg FN Owlet no no Siemens RVS 21 with extension module yes with extension module with extension module with WebServer module Yes (with LPB module)
Aerogor Compact 44 W + DisplayBox W Heating / Cooling Aerogor Compact 44 W + ControlBox W Heating / Cooling / DHW A++/A++ water pipe connection 44,41 4,64 42,65 3,69 40,27 2,92 / / 36,13 3,60 34,73 2,93 33,00 2,33 / / 30,36 3,23 25,50 2,98 20,75 2,39 60 -20°C to +40°C yes 28,20 12,80 2,2 350 27 1776 x 1371 x 1246 535 x 350 x 590 3 x 400 / 50 Hz 0 61 1 1/2 inner 10000 4,10 0,043 max 20 7 5 x 6 mm2 5 x 6 mm2 UTP & 5 x 0,75 mm2 32 A / C 16,80 28,90 MCD201 44,35 R407C 12,00 EEV Copeland SCROLL ZH 1 yes Ziehl Abegg FN Owlet no no Siemens RVS 21 with extension module yes with extension module with extension module with WebServer module Yes (with LPB module)
Aerogor Compact 54 W + DisplayBox W Heating / Cooling Aerogor Compact 54 W + ControlBox W Heating / Cooling / DHW A++/A++ water pipe connection 53,83 4,77 51,70 3,79 48,82 3,00 / / 43,80 3,70 42,10 3,70 40,00 2,39 / / 36,80 3,32 30,92 3,06 25,15 2,45 60 -20°C to +40°C yes 34,20 15,50 2,2 350 27 1776 x 1371 x 1246 535 x 350 x 590 3 x 400 / 50 Hz 0 66 1 1/2 inner 14067 5,10 0,061 max 20 7 5 x 10 mm2 5 x 10 mm2 UTP & 5 x 0,75 mm2 40 A / C 18,00 36,30 MCD201 47,52 R407C 12,50 EEV Copeland SCROLL ZH 1 yes Ziehl Abegg FN Owlet no no Siemens RVS 21 with extension module yes with extension module with extension module with WebServer module Yes (with LPB module)
Aerogor Compact EVI 27 W + DisplayBox W Heating / Cooling Aerogor Compact EVI 27 W + ControlBox W Heating / Cooling / DHW A++/A++ water pipe connection 25,90 4,79 26,20 3,93 26,68 3,23 26,78 2,65 22,20 3,70 22,36 3,04 22,62 2,49 22,86 2,05 20,54 3,35 19,14 3,01 15,93 2,52 65 -20°C to +40°C yes 18,60 8,00 2,3 350 27 1776 x 1371 x 1246 535 x 350 x 590 3 x 400 / 50 Hz 0 58 1 1/4 inner 10300 3,90 0,057 max 20 5 5 x 6 mm2 5 x 6 mm2 UTP & 5 x 0,75 mm2 32 A / C 11,80 29,90 MCI 25 31,15 R407C 8,20 EEV Copeland SCROLL EVI 1 yes Ziehl Abegg FN Owlet no no Siemens RVS 21 with extension module yes with extension module with extension module with WebServer module Yes (with LPB module)
AEROGOR COMPACT W + DisplayBox W / ControlBox W
System air / water - Compact outdoor unit
Model name
Basic solution:
Operating modes Model name
Advanced solution:
Operating modes ErP energy class (LT/HT) Connection between outdoor unit and heating system Heating capacity A7/W35 COP A7/W35 Heating capacity A7/W45 COP A7/W45 Heating capacity A7/W55 COP A7/W55 Heating capacity A7/W65 COP A7/W65 Heating capacity A2/W35 COP A2/W35 Heating capacity A2/W45 COP A2/W45 Heating capacity A2/W55 COP A2/W55 Heating capacity A2/W65 COP A2/W65 Heating capacity A-2/W35 COP A-2/W35 Heating capacity A-7/W35 COP A-7/W35 Heating capacity A-15/W35 COP A-15/W35 Maximum outlet water temperature Operating range Active cooling Cooling capacity - reversible operation A35/W12 Power input - reversible operation A35/W12 ERR Neto weight - outdoor unit Neto weight - indoor unit Dimensions of outdoor unit (W x D x H) Dimensions of indoor unit (W x D x H) Voltage Noise emissions [5m] - indoor unit Noise emissions [8m] - outdoor unit Connecting dimensions – secondary side Type of screw thread - outdoor unit Air flow - primary side Nominal water flow - secondary side Pressure drop - primary side Pressure drop - secondary side Recommended temperature difference (flow / return) Main connection cable – dimension Power connection (indoor - outdoor unit) Electrical connection cable between indoor - outdoor unit [sheathed] Fuse / Type Current – nominal Current – maximal Softstart Starting current Type of refrigerant Volume of refrigerant Type of expansion valve Type of compressor Number of compressors Circulating pumps - return flow Fan type Back-up electrical flow heater 3-way diverting valve Serial integrated controller Control of mixing heating cirquit Control of direct heating cirquit Solar system control ModBus WebControl Option for cascade system
*LT/HT = low temperature / high or medium temperature systems.
kW / kW / kW / kW / kW / kW / kW / kW / kW / kW / kW / °C °C / kW kW / kg kg mm mm V/Hz dB dB ” / m3/h m3/h kPa kPa K mm2 mm2 mm2 A A A / A / kg / / / / / / / / / / / / / /
Aerogor Compact EVI 37 W + DisplayBox W Heating / Cooling Aerogor Compact EVI 37 W + ControlBox W Heating / Cooling / DHW A++/A++ water pipe connection 35,58 4,79 36,00 3,93 36,66 3,23 36,80 2,65 30,50 3,70 30,72 30,40 31,08 2,49 31,41 2,05 28,23 3,35 26,30 3,01 21,88 2,52 65 -20°C to +40°C yes 23,90 10,80 2,2 380 27 1776 x 1371 x 1246 535 x 350 x 590 3 x 400 / 50 Hz 0 61 1 1/2 inner 10300 5,20 0,075 max 20 5 5 x 6 mm2 5 x 6 mm2 UTP & 5 x 0,75 mm2 32 A / C 14,60 27,10 MCI 25 38,54 R407C 9,50 EEV Copeland SCROLL EVI 1 yes Ziehl Abegg FN Owlet no no Siemens RVS 21 with extension module yes with extension module with extension module with WebServer module Yes (with LPB module)
Aerogor Compact EVI 48 W + DisplayBox W Heating / Cooling Aerogor Compact EVI 48 W + ControlBox W Heating / Cooling / DHW A++/A++ water pipe connection 47,13 4,91 47,68 4,04 48,56 3,31 48,74 2,72 40,40 3,80 40,69 3,12 41,17 2,56 41,61 2,10 37,39 3,44 34,84 3,09 28,98 2,59 65 -20°C to +40°C yes 31,80 13,80 2,3 380 27 1776 x 1371 x 1246 535 x 350 x 590 3 x 400 / 50 Hz 0 66 1 1/2 inner 14067 4,80 0,043 max 20 7 5 x 10 mm2 5 x 10 mm2 UTP & 5 x 0,75 mm2 32 A / C 16,80 30,60 MCD201 44,35 R407C 13,00 EEV Copeland SCROLL EVI 1 yes Ziehl Abegg FN Owlet no no Siemens RVS 21 with extension module yes with extension module with extension module with WebServer module Yes (with LPB module)
Aerogor Compact EVI 56 W + DisplayBox W Heating / Cooling Aerogor Compact EVI 56 W + ControlBox W Heating / Cooling / DHW A++/A++ water pipe connection 54,95 4,91 55,59 4,04 56,61 3,31 56,83 2,72 47,10 3,80 47,44 3,12 48,00 2,56 48,51 2,10 43,59 3,44 40,62 3,09 33,79 2,59 65 -20°C to +40°C yes 36,80 16,70 2,2 390 27 1776 x 1371 x 1246 535 x 350 x 590 3 x 400 / 50 Hz 0 66 1 1/2 inner 14067 5,70 0,061 max 20 7 5 x 10 mm2 5 x 10 mm2 UTP & 5 x 0,75 mm2 40 A / C 20,80 35,90 MCD201 51,91 R407C 14,00 EEV Copeland SCROLL EVI 1 yes Ziehl Abegg FN Owlet no no Siemens RVS 21 with extension module yes with extension module with extension module with WebServer module Yes (with LPB module)
25
AEROGOR SPLIT AW W and SPLIT AW EVI W
Split system air / water : outdoor unit + indoor unit 26
Model name Operating modes ErP energy class (LT/HT) Connection between outdoor and indoor unit Heating capacity A7/W35 COP A7/W35 Heating capacity A7/W45 COP A7/W45 Heating capacity A7/W55 COP A7/W55 Heating capacity A7/W65 COP A7/W65 Heating capacity A2/W35 COP A2/W35 Heating capacity A2/W45 COP A2/W45 Heating capacity A2/W55 COP A2/W55 Heating capacity A2/W65 COP A2/W65 Heating capacity A-2/W35 COP A-2/W35 Heating capacity A-7/W35 COP A-7/W35 Heating capacity A-15/W35 COP A-15/W35 Maximum outlet water temperature Operating range Active cooling Cooling capacity - reversible operation A35/W12 Power input - reversible operation A35/W12 ERR Neto weight - outdoor unit Neto weight - indoor unit Dimensions of outdoor unit (W x D x H) Dimensions of indoor unit (W x D x H) Voltage Noise emissions [5m] - indoor unit Noise emissions [8m] - outdoor unit Connecting dimensions – primary side Connecting dimensions – secondary side Type of screw thread - outdoor unit Air flow - primary side Nominal water flow - secondary side Pressure drop - primary side Pressure drop - secondary side Recommended temperature difference (flow / return) Main connection cable – dimension Power connection (indoor - outdoor unit) Electrical connection cable between indoor - outdoor unit [sheathed] Fuse / Type Current – nominal Current – maximal Softstart Starting current Type of refrigerant Volume of refrigerant Type of expansion valve Type of compressor Number of compressors Circulating pumps - return flow Fan type Back-up electrical flow heater 3-way diverting valve Serial integrated controller Control of mixing heating cirquit Control of direct heating cirquit Solar system control ModBus WebControl Option for cascade system *LT/HT = low temperature / high or medium temperature systems.
kW / kW / kW / kW / kW / kW / kW / kW / kW / kW / kW / °C °C / kW kW / kg kg mm mm V/Hz dB dB mm ” / 3 m /h m3/h kPa kPa K mm2 mm2 mm2 A A A / A / kg / / / / / / / / / / / / / /
Aerogor Split AW 25 W
Aerogor Split AW 36 W
Aerogor Split AW 44 W
Aerogor Split AW 54 W
Aerogor Split AW 47 EVI W
Aerogor Split AW 55 EVI W
Heating / Cooling / DHW A++/A++ Refrigerant pipe connection 25,31 4,64 24,30 3,69 22,95 2,92 / / 20,59 3,60 19,79 2,93 18,81 2,33 / / 17,30 3,23 14,53 2,98 11,82 2,39 60 -20°C to +40°C yes 16,5 7,1 2,3 149 142 800 x 580 x 1105 800 x 900 x 775 3 x 400 / 50 Hz 52 54 16 mm / 28 mm 1 1/4” inner 4959 3,2 0,05 max 20 5 5 x 6 mm2 3 x 1,5 mm2 10 x 0,75 mm2 32 A / C 11,6 27,9 MCI 25 30,62 R407C 7 EEV Copeland SCROLL ZH 1 yes Ziehl Abegg FN Owlet no no Siemens RVS 61 yes yes yes with extension module z Web modulom Yes (with LPB module)
Heating / Cooling / DHW A++/A++ Refrigerant pipe connection 35,77 4,77 34,35 3,79 32,43 3,00 / / 29,10 3,70 27,97 3,02 26,58 2,39 / / 24,45 3,32 20,54 3,06 16,71 2,45 60 -20°C to +40°C yes 23,3 10,1 2,3 170 155 800 x 580 x 1105 1200 x 1290 x 1045 3 x 400 / 50 Hz 54 59 18 mm / 28 mm 1 1/2” inner 5800 4,6 0,057 max 20 5 5 x 6 mm2 3 x 1,5 mm2 10 x 0,75 mm2 25 A / C 11,8 23,9 MCI 25 31,15 R407C 7,3 EEV Copeland SCROLL ZH 1 yes Ziehl Abegg FN Owlet no no Siemens RVS 61 yes yes yes with extension module z Web modulom Yes (with LPB module)
Heating / Cooling / DHW A++/A++ Refrigerant pipe connection 44,41 4,64 42,65 3,69 40,27 2,92 / / 36,13 3,60 34,73 2,93 33,00 2,33 / / 30,36 3,23 25,50 2,98 20,75 2,39 60 -20°C to +40°C yes 28,2 12,8 2,2 175 185 800 x 785 x 1105 1200 x 1290 x 1045 3 x 400 / 50 Hz 55 59 18 mm / 35 mm 1 1/2” inner 10.000 4,1 0,043 max 20 7 5 x 6 mm2 3 x 1,5 mm2 10 x 0,75 mm2 32 A / C 16,8 28,9 MCD201 44,35 R407C 12 EEV Copeland SCROLL ZH 1 yes Ziehl Abegg FN Owlet no no Siemens RVS 61 yes yes yes with extension module z Web modulom Yes (with LPB module)
Heating / Cooling / DHW A++/A++ Refrigerant pipe connection 53,83 4,77 51,70 3,79 48,83 3,00 / / 43,80 3,70 42,10 3,02 40,00 2,39 / / 36,80 3,32 30,92 3,06 25,15 2,45 60 -20°C to +40°C yes 34,2 15,5 2,2 198 185 800 x 785 x 1105 1200 x 1290 x 1045 3 x 400 / 50 Hz 57 64 22 mm / 35 mm 1 1/2” inner 14.067 5,1 0,061 max 20 7 5 x 10 mm2 3 x 1,5 mm2 10 x 0,75 mm2 40 A / C 18 36,3 MCD201 47,52 R407C 12,5 EEV Copeland SCROLL ZH 1 yes Ziehl Abegg FN Owlet no no Siemens RVS 61 yes yes yes with extension module z Web modulom Yes (with LPB module)
Heating / Cooling / DHW A++/A++ Refrigerant pipe connection 47,13 4,91 47,68 4,04 48,56 3,31 48,74 2,72 40,40 3,80 40,69 3,12 41,17 2,56 41,61 2,10 37,39 3,44 34,84 3,09 28,98 2,59 65 -20°C to +40°C yes 31,8 13,8 2,3 210 185 800 x 785 x 1105 1200 x 1290 x 1045 3 x 400 / 50 Hz 55 64 18mm / 35mm 1 1/2” inner 14067 4,8 0,043 max 20 7 5 x 10 mm2 3 x 1,5 mm2 10 x 0,75 mm2 32 A / C 16,8 30,6 MCD201 44,35 R407C 13 EEV Copeland SCROLL EVI 1 yes Ziehl Abegg FN Owlet no no Siemens RVS 61 yes yes yes with extension module with WebServer module Yes (with LPB module)
Heating / Cooling / DHW A++/A++ Refrigerant pipe connection 54,95 4,91 55,59 4,04 56,61 3,31 56,83 2,72 47,10 3,80 47,44 3,12 48,00 2,56 48,51 2,10 43,59 3,44 40,62 3,09 33,79 2,59 65 -20°C to +40°C yes 36,8 16,7 2,2 210 185 800 x 785 x 1105 1200 x 1290 x 1045 3 x 400 / 50 Hz 57 64 22 mm / 35 mm 1 1/2” inner 14067 5,7 0,061 max 20 7 5 x 10 mm2 3 x 1,5 mm2 10 x 0,75 mm2 40 A / C 20,8 35,9 MCD201 54,91 R407C 14 EEV Copeland SCROLL EVI 1 yes Ziehl Abegg FN Owlet no no Siemens RVS 61 yes yes yes with extension module with WebServer module Yes (with LPB module)
AEROGOR SPLIT AW W and SPLIT AW EVI W
Split system air / water : outdoor unit + indoor unit
Model name
Aerogor Split AW 20 EVI W
Aerogor Split AW 26 EVI W
Aerogor Split AW 36 EVI W
Aerogor Split AW 47 EVI W
Aerogor Split AW 55 EVI W
Operating modes ErP energy class (LT/HT) Connection between outdoor and indoor unit Heating capacity A7/W35 COP A7/W35 Heating capacity A7/W45 COP A7/W45 Heating capacity A7/W55 COP A7/W55 Heating capacity A7/W65 COP A7/W65 Heating capacity A2/W35 COP A2/W35 Heating capacity A2/W45 COP A2/W45 Heating capacity A2/W55 COP A2/W55 Heating capacity A2/W65 COP A2/W65 Heating capacity A-2/W35 COP A-2/W35 Heating capacity A-7/W35 COP A-7/W35 Heating capacity A-15/W35 COP A-15/W35 Maximum outlet water temperature Operating range Active cooling Cooling capacity - reversible operation A35/W12 Power input - reversible operation A35/W12 ERR Neto weight - outdoor unit Neto weight - indoor unit Dimensions of outdoor unit (W x D x H) Dimensions of indoor unit (W x D x H) Voltage Noise emissions [5m] - indoor unit Noise emissions [8m] - outdoor unit Connecting dimensions – primary side Connecting dimensions – secondary side Type of screw thread - outdoor unit Air flow - primary side Nominal water flow - secondary side Pressure drop - primary side Pressure drop - secondary side Recommended temperature difference (flow / return) Main connection cable – dimension Power connection (indoor - outdoor unit) Electrical connection cable between indoor - outdoor unit [sheathed] Fuse / Type Current – nominal Current – maximal Softstart Starting current Type of refrigerant Volume of refrigerant Type of expansion valve Type of compressor Number of compressors Circulating pumps - return flow Fan type Back-up electrical flow heater Serial integrated controller Control of mixing heating cirquit Control of direct heating cirquit Solar system control ModBus WebControl Option for cascade system
Heating / Cooling / DHW A++/A++ Refrigerant pipe connection 19,95 4,91 20,18 4,04 20,55 3,31 20,63 2,72 17,10 3,80 17,22 3,12 17,43 2,56 17,61 2,10 15,82 3,44 14,75 3,09 12,27 2,59 65 -20°C to +40°C yes 14,6 6,6 2,2 145 142 600 x 580 x 1105 800 x 900 x 775 3 x 400 / 50 Hz 48 54 12 mm / 22 mm 1 1/4” inner 4959 3 0,05 max 20 5 5 x 4 mm2 3 x 1,5 mm2 10 x 0,75 mm2 25 A / C 9,7 25,5 MCI 15 25,6 R407C 5,9 4.5 (12/16) Copeland SCROLL EVI 1 yes Ziehl Abegg FN Owlet yes, 3 x 2kW Siemens RVS 61 yes yes yes with extension module with WebServer module Yes (with LPB module)
Heating / Cooling / DHW A++/A++ Refrigerant pipe connection 25,90 4,79 26,20 3,93 26,68 3,23 26,78 2,65 22,20 3,70 22,36 3,04 22,62 2,49 22,86 2,05 20,54 3,35 19,14 3,01 15,93 2,52 65 -20°C to +40°C yes 18,6 8 2,3 185 155 800 x 580 x 1105 1200 x 1290 x 1045 3 x 400 / 50 Hz 49 59 16 mm / 28 mm 1 1/4” inner 10.300 3,9 0,057 max 20 5 5 x 6 mm2 3 x 1,5 mm2 10 x 0,75 mm2 32 A / C 11,8 29,9 MCI 25 31,15 R407C 8,2 EEV Copeland SCROLL EVI 1 yes Ziehl Abegg FN Owlet no Siemens RVS 61 yes yes yes with extension module with WebServer module Yes (with LPB module)
Heating / Cooling / DHW A++/A++ Refrigerant pipe connection 35,58 4,79 36,00 3,93 36,66 3,23 36,80 2,65 30,50 3,70 30,72 3,04 31,08 2,49 31,41 2,05 28,23 3,35 26,30 3,01 21,88 2,52 65 -20°C to +40°C yes 23,9 10,8 2,2 195 155 800 x 580 x 1105 1200 x 1290 x 1045 3 x 400 / 50 Hz 53 59 16mm / 28mm 1 1/2” inner 10.300 5,2 0,075 max 20 5 5 x 6 mm2 3 x 1,5 mm2 10 x 0,75 mm2 32 A / C 14,6 27,1 MCI 25 38,54 R407C 9,5 EEV Copeland SCROLL EVI 1 yes Ziehl Abegg FN Owlet no Siemens RVS 61 yes yes yes with extension module with WebServer module Yes (with LPB module)
Heating / Cooling / DHW A++/A++ Refrigerant pipe connection 47,13 4,91 47,68 4,04 48,56 3,31 48,74 2,72 40,40 3,80 40,69 3,12 41,17 2,56 41,61 2,10 37,39 3,44 34,84 3,09 28,98 2,59 65 -20°C to +40°C yes 31,8 13,8 2,3 210 185 800 x 785 x 1105 1200 x 1290 x 1045 3 x 400 / 50 Hz 55 64 18mm / 35mm 1 1/2” inner 14067 4,8 0,043 max 20 7 5 x 10 mm2 3 x 1,5 mm2 10 x 0,75 mm2 32 A / C 16,8 30,6 MCD201 44,35 R407C 13 EEV Copeland SCROLL EVI 1 yes Ziehl Abegg FN Owlet no Siemens RVS 61 yes yes yes with extension module with WebServer module Yes (with LPB module)
Heating / Cooling / DHW A++/A++ Refrigerant pipe connection 54,95 4,91 55,59 4,04 56,61 3,31 56,83 2,72 47,10 3,80 47,44 3,12 48,00 2,56 48,51 2,10 43,59 3,44 40,62 3,09 33,79 2,59 65 -20°C to +40°C yes 36,8 16,7 2,2 210 185 800 x 785 x 1105 1200 x 1290 x 1045 3 x 400 / 50 Hz 57 64 22 mm / 35 mm 1 1/2” inner 14067 5,7 0,061 max 20 7 5 x 10 mm2 3 x 1,5 mm2 10 x 0,75 mm2 40 A / C 20,8 35,9 MCD201 54,91 R407C 14 EEV Copeland SCROLL EVI 1 yes Ziehl Abegg FN Owlet no Siemens RVS 61 yes yes yes with extension module with WebServer module Yes (with LPB module)
*LT/HT = low temperature / high or medium temperature systems.
kW / kW / kW / kW / kW / kW / kW / kW / kW / kW / kW / °C °C / kW kW / kg kg mm mm V/Hz dB dB mm ” / 3 m /h m3/h kPa kPa K mm2 mm2 mm2 A A A / A / kg / / / / / / / / / / / / /
27
TERRAGOR W - AQUAGOR W and TERRAGOR - AQUAGOR EVI W
System brine-water and water-water 28
Terragor 28 W Aquagor 37 W
Terragor 38 W Aquagor 50 W
Terragor 43 W Aquagor 59 W
Terragor 52 W Aquagor 67 W
Terragor 56 W Aquagor 78 W
Terragor 65 W Aquagor 89 W
Heating / Cooling / DHW
Heating / Cooling / DHW
Heating / Cooling / DHW
Heating / Cooling / DHW
Heating / Cooling / DHW
Heating / Cooling / DHW
477707
452305
477709
452306
477710
452297
kW
26,00
37,90
42,31
47,58
55,42
64,60
/
4,17
4,50
4,17
4,17
4,24
4,46
kW
24,63
33,67
40,09
45,08
52,50
60,06
Model name Operating modes Code number Heating capacity B0/W35 COP B0/W35 Heating capacity B0/W45 COP B0/W45 Heating capacity B0/W55 COP B0/W55 Heating capacity B0/W65 COP B0/W65 Heating capacity W10/W35 COP W10/W35 Heating capacity W10/W45 COP W10/W45 Heating capacity W10/W55 COP W10/W55 Heating capacity W10/W65 COP W10/W65
/
3,32
3,38
3,32
3,32
3,38
3,38
kW
22,70
31,12
37,05
41,67
48,53
55,51 2,61
/
2,56
2,61
2,56
2,56
2,61
kW
/
/
/
/
/
/
/
/
/
/
/
/
/
kW
36,50
49,90
59,40
66,80
77,80
89,00
/
5,60
5,70
5,60
5,60
5,70
5,70
kW
34,50
47,17
56,15
63,14
73,54
84,12
/
4,44
4,52
4,44
4,44
4,52
4,52
kW
31,96
43,69
52,01
58,49
68,12
77,93 3,49
/
3,43
3,49
3,43
3,43
3,49
kW
/
/
/
/
/
/
/
/
/
/
/
/
/
Maximum outlet water temperature
°C
60
60
60
60
60
60
Operating range of heat pumps brine - water
°C
–5 °C to +25°C
–5 °C to +25°C
–5 °C to +25°C
–5 °C to +25°C
–5 °C to +25°C
–5 °C to +25°C
Operating range of heat pumps water - water
°C
+7°C to +25°C
+7°C to +25°C
+7°C to +25°C
+7°C to +25°C
+7°C to +25°C
+7°C to +25°C
/
no
no
no
no
no
no
kg
248
264
311
355
368
386
Dimensions of indoor unit (W x D x H)
mm
800 x 580 x 1105
1000 x 785 x 1105
1000 x 785 x 1105
1000 x 785 x 1105
1000 x 785 x 1105
1000 x 785 x 1105
Napetost
V/Hz
3 x 400 / 50 Hz
3 x 400 / 50 Hz
3 x 400 / 50 Hz
3 x 400 / 50 Hz
3 x 400 / 50 Hz
3 x 400 / 50 Hz
dB
53
55
56
56
59
59
Connecting dimensions – primary side
˝
1 1/2”
1 1/2”
2”
2”
2”
2”
Connecting dimensions – secondary side
˝
1 1/4”
1 1/2”
2”
2”
2”
2” 10,6
Pre-heat exchanger on primary side (for water-water system) Neto weight
Noise emissions [5m] - indoor unit
Volume of flow - primary side
m 3/h
5,2
5,5
7,1
8,6
9,3
Nominal water flow - secondary side
m3/h
4,8
4,2
5,3
6,4
6,9
7,8
Pressure drop - primary side
kPa
max 20
max 20
max 20
max 20
max 20
max 20
Pressure drop - secondary side
max 20
kPa
max 20
max 20
max 20
max 20
max 20
Recommended temperature difference (flow / return) - primary side
K
5
7
7
7
7
7
Recommended temperature difference (flow / return) - secondary side
K
5
5
5
5
5
5
Main connection cable – dimension
mm2
5 x 6 mm2
5 x 6 mm2
5 x 6 mm2
5 x 10 mm2
5 x 10 mm2
5 x 16 mm2
Power connection cable
mm2
5 x 1,5 mm2
5 x 1,5 mm2
5 x 1,5 mm2
5 x 2,5 mm2
5 x 2,5 mm2
5 x 2,5 mm2 50 A / C
Fuse / Type
A
25 A / C
32 A / C
32 A / C
40 A / C
40 A / C
Current – nominal
A
14,3
17,5
21
23,6
25,6
27,8
Current – maximal
A
24
32
31,8
33,6
39,2
44,6 2 x MCI25
Softstart
/
2 x MCI12
2 x MCI15
2 x MCI15
2 x MCI25
2 x MCI25
Starting current
A
37,75
46,2
55,44
62,3
67,58
73,39
Type of refrigerant
/
R407C
R407C
R407C
R407C
R407C
R407C
Volume of refrigerant Type of compressor
kg
6,7
8,4
8,8
9,2
9,6
8,8
/
TANDEM Copeland Scroll
TANDEM Copeland Scroll
TANDEM Copeland Scroll
TANDEM Copeland Scroll
TANDEM Copeland Scroll
TANDEM Copeland Scroll
Number of compressors
/
2
2
2
2
2
2
Circulating pumps - return flow
/
no
no
no
no
no
no
Back-up electrical flow heater
/
no
no
no
no
no
no
3-way diverting valve
/
no
no
no
no
no
no
Control of mixing heating cirquit
/
yes
yes
yes
yes
yes
yes
Control of direct heating cirquit
/
yes
yes
yes
yes
yes
yes
Solar system control
/
yes
yes
yes
yes
yes
yes
ModBus
/
with extension module
with extension module
with extension module
with extension module
with extension module
with extension module
WebControl
/
with WebServer module
with WebServer module
with WebServer module
with WebServer module
with WebServer module
with WebServer module
Serial integrated controller
/
Siemens RVS 61
Siemens RVS 61
Siemens RVS 61
Siemens RVS 61
Siemens RVS 61
Siemens RVS 61
Option for cascade system
/
yes
yes
yes
yes
yes
yes
Type and material of heat exchanger - primary side
/
plate heat exchanger / AISI 316
plate heat exchanger / AISI 316
plate heat exchanger / AISI 316
plate heat exchanger / AISI 316
plate heat exchanger / AISI 316
plate heat exchanger / AISI 316
Type and material of heat exchanger - secondary side
/
plate heat exchanger / AISI 316
plate heat exchanger / AISI 316
plate heat exchanger / AISI 316
plate heat exchanger / AISI 316
plate heat exchanger / AISI 316
plate heat exchanger / AISI 316
Recommended water filter for heat pump water-water
mcr
300 - 500
300 - 500
300 - 500
300 - 500
300 - 500
300 - 500
*LT/HT = low temperature / high or medium temperature systems.
TERRAGOR W - AQUAGOR W and TERRAGOR - AQUAGOR EVI W
System brine-water and water-water
Terragor 70 W Aquagor 100 W
Terragor 83 W Aquagor 115 W
Terragor EVI 37 W Aquagor EVI 48 W
Terragor EVI 67 W Aquagor EVI 87 W
Terragor EVI 81 W Aquagor EVI 105 W
Terragor EVI 98 W Aquagor EVI 126 W
Heating / Cooling / DHW
Heating / Cooling / DHW
Heating / Cooling / DHW
Heating / Cooling / DHW
Heating / Cooling / DHW
Heating / Cooling / DHW
477711
452298
452299
452300
477712
452302
kW
70,52
83,20
37,45
67,17
81,24
98,05
/
4,17
4,35
4,50
4,50
4,50
4,40
kW
66,81
77,47
37,90
67,98
82,21
99,23
Model name Operating modes Code number Heating capacity B0/W35 COP B0/W35 Heating capacity B0/W45 COP B0/W45 Heating capacity B0/W55 COP B0/W55 Heating capacity B0/W65 COP B0/W65 Heating capacity W10/W35 COP W10/W35 Heating capacity W10/W45 COP W10/W45 Heating capacity W10/W55 COP W10/W55 Heating capacity W10/W65 COP W10/W65
/
3,32
3,26
3,70
3,70
3,70
3,62
kW
61,75
71,60
38,50
69,05
83,51
100,80
/
2,56
2,51
2,96
2,96
2,96
2,89
kW
/
/
39,10
70,13
84,81
102,36
/
/
/
2,53
2,53
2,53
2,47
kW
99,00
114,80
48,24
86,51
104,64
126,29
/
5,60
5,50
4,55
4,55
4,55
4,44
kW
93,58
108,51
50,18
90,01
108,86
131,39
/
4,44
4,36
4,56
4,56
4,56
4,46
kW
86,69
100,52
50,18
90,01
108,86
131,39
/
3,43
3,37
3,75
3,75
3,75
3,66
kW
/
/
49,88
89,47
108,21
130,60 3,06
/
/
/
3,12
3,12
3,12
Maximum outlet water temperature
°C
60
60
65
65
65
65
Operating range of heat pumps brine - water
°C
–5 °C to +25°C
–5 °C to +25°C
–5 °C to +25°C
–5 °C to +25°C
–5 °C to +25°C
–5 °C to +25°C
Operating range of heat pumps water - water
°C
+7°C to +25°C
+7°C to +25°C
+7°C to +25°C
+7°C to +25°C
+7°C to +25°C
+7°C to +25°C
/
no
no
yes
yes
yes
yes
kg
415
438
265
325
348
368
Dimensions of indoor unit (W x D x H)
mm
1000 x 785 x 1105
1000 x 785 x 1105
800 x 580 x 1105
1000 x 785 x 1105
1000 x 785 x 1105
1000 x 785 x 1105
Napetost
V/Hz
3 x 400 / 50 Hz
3 x 400 / 50 Hz
3 x 400 / 50 Hz
3 x 400 / 50 Hz
3 x 400 / 50 Hz
3 x 400 / 50 Hz
dB
60
63
52
54
56
56
Connecting dimensions – primary side
˝
2”
2”
2”
2”
2”
2”
Connecting dimensions – secondary side
˝
2”
2”
1 1/2”
2”
2”
2”
Volume of flow - primary side
m3/h
11,4
13,5
6,8
10,4
13,2
16
Nominal water flow - secondary side
Pre-heat exchanger on primary side (for water-water system) Neto weight
Noise emissions [5m] - indoor unit
m3/h
8,5
10,1
6,1
7,7
9,7
11,7
Pressure drop - primary side
kPa
max 20
max 20
max 20
max 20
max 20
max 20
Pressure drop - secondary side
max 20
kPa
max 20
max 20
max 20
max 20
max 20
Recommended temperature difference (flow / return) - primary side
K
7
7
5
7
7
7
Recommended temperature difference (flow / return) - secondary side
K
5
5
5
5
5
5
Main connection cable – dimension
mm2
5 x 16 mm2
5 x 25 mm2
5 x 6 mm2
5 x 10 mm2
5 x 16 mm2
5 x 16 mm2
Power connection cable
mm2
5 x 2,5 mm2
5 x 2,5 mm2
5 x 1,5 mm2
5 x 2,5 mm2
5 x 2,5 mm2
5 x 2,5 mm2
Fuse / Type
A
63 A / C
80 A / C
25 A / C
40 A / C
50 A / C
80 A / C
Current – nominal
A
33
44,6
17,3
23,6
27,8
33
Current – maximal
A
54
78
34
33,6
44,6
54
Softstart
/
2 x MCD201
2 x MCD201
2 x MCI25
2 x MCD201
2 x MCD201
Starting current
A
87,12
117,74
46,5
62,3
73,39
87,12
Type of refrigerant
/
R407C
R407C
R407C
R407C
R407C
R407C
Volume of refrigerant
kg
9,4
10,2
8,7
6,2
6,7
8,9
Type of compressor
/
TANDEM Copeland Scroll
TANDEM Copeland Scroll
TANDEM Copeland Scroll
Copeland SCROLL EVI
Copeland SCROLL EVI
Copeland SCROLL EVI
Number of compressors
/
2
2
2
2
2
2
Circulating pumps - return flow
/
no
no
no
no
no
no no
Back-up electrical flow heater
/
no
no
no
no
no
3-way diverting valve
/
no
no
no
no
no
no
Control of mixing heating cirquit
/
yes
yes
yes
yes
yes
yes
Control of direct heating cirquit
/
yes
yes
yes
yes
yes
yes
Solar system control
/
yes
yes
yes
yes
yes
yes
ModBus
/
with extension module
with extension module
with extension module
with extension module
with extension module
with extension module
WebControl
/
with WebServer module
with WebServer module
with WebServer module
with WebServer module
with WebServer module
with WebServer module
Serial integrated controller
/
Siemens RVS 61
Siemens RVS 61
Siemens RVS 61
Siemens RVS 61
Siemens RVS 61
Siemens RVS 61
Option for cascade system
/
yes
yes
yes
yes
yes
yes
Type and material of heat exchanger - primary side
/
plate heat exchanger / AISI 316
plate heat exchanger / AISI 316
plate heat exchanger / AISI 304
plate heat exchanger / AISI 304
plate heat exchanger / AISI 304
plate heat exchanger / AISI 304
Type and material of heat exchanger - secondary side
/
plate heat exchanger / AISI 316
plate heat exchanger / AISI 316
plate heat exchanger / AISI 316
plate heat exchanger / AISI 316
plate heat exchanger / AISI 316
plate heat exchanger / AISI 316
Recommended water filter for heat pump water-water
mcr
300 - 500
300 - 500
300 - 500
300 - 500
300 - 500
300 - 500
*LT/HT = low temperature / high or medium temperature systems.
29
GORENJE d.d. Heating Systems Partizanska 12 SI – 3503 Velenje | Slovenia T + 386 3 899 10 00 F + 386 3 899 72 73 toplotnecrpalke@gorenje.com www.gorenje.com