DIGITAL FLOW CARE.
ALARM MANAGEMENT OF MEDICAL GAS PIPELINE SYSTEM.
Full bore ball valves to allow instant shut-off of main, risers or branch lines of a Pipeline system. These are de-greased, pressure tested and blown clean. End fittings made of brass are provided to facilitate joining with copper line pipes by brazing or soldering without damaging seal components of valves
Advertisement
Technical Features
Microprocessor based digital LCD alarm
Highly visible 7" (178 mm) LCD screen
Pressure sensing through piezoresistive sensing Technology
Alarms can be monitored audio-visual Touch screen operation`
Data display at a central monitoring station Real time updating of status
Operational parameters i.e. high and low level can` be set “in-situ” to suit requirement in an area.
Programmable pressure unit display (bar, kg/cm &mmHg). Audio mute option.
![](https://assets.isu.pub/document-structure/230522115418-d1467041c23505c41cdf0bf07878f1f2/v1/92a0c4a09ccc82cd1c7177b8eca422b7.jpeg?width=720&quality=85%2C50)
Designed to serve 2, 3, 4, 5 & 6 gases including Vacuum
Powered by 220V AC to 24V DC external adapter
Technical Specifications
Conforms to
Body
Finish
Mounting type
Enclosure dimensions
Gas services
Gas & Vacuum connection
Power connection
Warning system
Touch Screen Display`
ISO
Fire retardant dust-proof CRCA 18 SWG steel enclosure (NEMA 1 Enclosure)
Fire retardant dust-proof CRCA 18 SWG steel enclosure (NEMA 1 Enclosure)
Horizontal - Surface mountable (Cover opens up horizontally)
330 × 250 × 100 (L × H × T in mm)
2, 3, 4, 5 & 6 Gas including Vacuum
NIST connection for gas input
External 220V AC (50 Hz) to 24V DC adapter for audio visual display
Microprocessor based warning module should be adjustable in-situ to set operational parameters and digital pressure unit in psi / bar or kg/cm2
Digital & illuminated touch screen display for “Normal”, “High” & “Low” with High/low alarm set point for each gas (Low only for Vacuum) service Visible display coupled with audio warning in case of preset with the provision of “Mute” audio signal for 15 minutes max
Sensors
Fully calibrated and temperature compensated application specific Integrated Circuit signal conditioning (in a brass housing) Pressure Sensors a. Total Error Band: ±1.0% FSS (Full Scale Span) from -20 °C to 85 °C [-4 °F to 185 °F] b. Sensing pressure span : 60 mbar to 10 bar [ 1 psi to 150 psi] Digital Output c. Temperature span : -30 °C to 50 °C [-22 °F to 122 °F]
Information & Control`
Display & Audio blocker
Earthling
Protection
Certifications
The information of alarm, current status & test conditions through “Touch Screen”
Provision to block display & audio signal of a particular supply line for long service period is builtin
Protective earth
Class II & IP54
ISO 13485 : 2016 - Medical devicesQuality Management Systems
ISO 9001 : 2015 - Quality Management Systems
Pressure Equipment Directive 2014/68/EU
BS OUTLET(METAL)
![](https://assets.isu.pub/document-structure/230522115418-d1467041c23505c41cdf0bf07878f1f2/v1/9b1d8ff123814bc1b7775ec0e6f4c1c5.jpeg?width=720&quality=85%2C50)
![](https://assets.isu.pub/document-structure/230522115418-d1467041c23505c41cdf0bf07878f1f2/v1/af703e0a945d29820b6749bf0c532a39.jpeg?width=720&quality=85%2C50)
Metal outlet has been developed to address the long standing need to simplify the service Requirement without supply disruption. Once Installed, the servicing /maintenance is possible Without removing the enclosure, making downtime to bare minimum for all types of mounting i.e. Wall, Pendant, Column, Bed head outlets etc. Increase in life cycle of the device is an additional benefit
Technical Features
Designed to bear load
Metal construction for superior strength
Servicing / maintenance sans supply disruption.
Recommended for direct mounting of secondary devices.
Gas Service
O2,N2O,CO2,Medical Air(AR4) & Mixed Gases
![](https://assets.isu.pub/document-structure/230522115418-d1467041c23505c41cdf0bf07878f1f2/v1/e7c7df3c66194a0fac41c5d1bb34880b.jpeg?width=720&quality=85%2C50)
![](https://assets.isu.pub/document-structure/230522115418-d1467041c23505c41cdf0bf07878f1f2/v1/f9f8f93eaefbc038e7eed815fd4cf70f.jpeg?width=720&quality=85%2C50)
![](https://assets.isu.pub/document-structure/230522115418-d1467041c23505c41cdf0bf07878f1f2/v1/776f74f1262abc3f6d9efb1bebb355ec.jpeg?width=720&quality=85%2C50)
![](https://assets.isu.pub/document-structure/230522115418-d1467041c23505c41cdf0bf07878f1f2/v1/4ea73543c41db6bd2d5af9ecde384e16.jpeg?width=720&quality=85%2C50)
![](https://assets.isu.pub/document-structure/230522115418-d1467041c23505c41cdf0bf07878f1f2/v1/f7553ce30889ccd4e45e0ab830fa93b7.jpeg?width=720&quality=85%2C50)
![](https://assets.isu.pub/document-structure/230522115418-d1467041c23505c41cdf0bf07878f1f2/v1/4fac191efea6250f5d7077f554a897bf.jpeg?width=720&quality=85%2C50)
![](https://assets.isu.pub/document-structure/230522115418-d1467041c23505c41cdf0bf07878f1f2/v1/d020f8e386bf8c17793b4a86904d16f9.jpeg?width=720&quality=85%2C50)