INDUSTRIAL

The Pursuit of Excellence in Motor Controls



CONTENTS Contactors pg. 5

Contactors, Overloads and Accessories Mira Contactors and Overloads

5

Orion Contactors and Overloads

11

Manual Motor Starters and Accessories . Manual Motor Starters

16

Manual Motor Starter Accessories

20

Relays, Overloads, Mini Contactors/Overloads Digital Motor Protection Relays

22

Electronic Overloads

23

Mini Contactors, Overloads & Relays

24

Mira Molded Case Circuit Breakers

Starters pg. 26

TD/TS Series Circuit Breakers & Accessories

28

Enclosed Manual Motor Starters

33

Industrial Enclosed Starters 36

Industrial Start Stop

38

Industrial Starters

42

16-21

22-25

26-33

44-59

Industrial and Pump Starter

44

Standard Pump Starter

48

Duplex Alternating Pump Starter

50

Enclosed VFD Pump Package

54

Variable Frequency Drives

pg. 60

5-15

34-43

Enclosed Starters

Pump Controls

VFDs

60-68

Micro-Single Phase C-Series VFD

60

Compact GS Series VFD

62

P-Series VFD

64

Resistors & Braking units

67

Additional Components

72-88

Line Reactors

72

Pressure Sensors

74

Soft Starts

76

Panel Components

80

SAFETY FIRST!

As with all electrical equipment, only qualified, expert personnel should perform maintenance and installation. Comply with all applicable local and national codes and laws that regulate the installation and operation of equipment and read manuals thoroughly. Use only installation manuals and not this sales brochure for installation procedures. It is up to the installer to determine product suitability for a given application. Š Product improvement is a continual process; pricing and specifications subject to change without notice. Marketing materials should not be relied upon for technical specification. Cerus, Mira, Orion, Titan and associated logos are trademarks of Cerus Industrial, Inc. All sales subject to Cerus Terms and Conditions.


MIRA Contactors and Overloads Installs in Minutes, Lasts a Lifetime 9~95 Amp Rated Models Integrated Lugs - Easy to Wire Without Additional Hardware DIN Rail Compatible Complete Line of Accessories and Adapters For Clean and Effective Installation Industry Leading 5-Year Warranty


Quality Design

Easy Mounting Accessories

Cerus MIRA contactors and overloads have been designed and tested to the world’s highest standards. Utilizing the Power Test and Technology Institute for rigorous testing, we have produced one of the world’s top performing and most durable UL listed contactor. The complete MIRA line of motor control components boasts one of the highest UL ratings attainable for interruption capacity when paired with our manual motor starters – as high as 100,000 amps interrupting.

The MIRA line includes accessories that offer easy installation, space savings and reduce overall cost. MIRA Bus bars, reversing kits, mating plates and DIN rail mounting hardware allow for comprehensive and highly flexible motor control solutions.

Performance & Reliability Our advanced design sets MIRA apart as one of the industry’s most durable line of motor controls. The combination of unique contact alloys and control of the electrical arc within the contactor extends the useful life to as many as 2.5 million electrical operations. MIRA is manufactured to ISO certified quality standards and backed by an industry leading 5-Year warranty.


INDUSTRIAL CATALOG

MIRA

Contactor Specifications 3-Pole, 9~95 Amp Contactors AC or DC Coil Voltages Frame Size Model Type Screw clamp terminals Lug terminals

NEMA Sized

32AF

63AF

95AF

MRC-9 MRC-12 MRC-18 MRC-25 MRC-32

MRC-35 MRC-40 MRC-50 MRC-63

MRC-65 MRC-75 MRC-85 MRC-95

-

-

-

-

-

Number of poles

3

3

3

690V

690V

690V

Conforming to IEC947-4-1

1000V

1000V

1000V

Conforming to UL, CSA

600V

Rated operational voltage, Ue Rated insulation voltage, Ui

600V

600V

Rated impulse withstand voltage, Uimp

8kV

8kV

8kV

Degree of pollution (IEC60529)

IP20

IP20

IP20

Rated operational current Ie (θ≤ 55 °C) AC-1 Ue max 690V [A] AC-3 200/240V [A]

25

25

40

40

50

55

60

70

75

100

110

135

140

11

13

18

25

32

35

40

55

63

65

75

85

95

380/400V

[A]

9

12

18

25

32

35

40

50

63

65

75

85

95

415V

[A]

9

12

18

25

32

35

40

50

63

65

75

85

95

440V

[A]

9

12

18

25

32

35

40

50

63

65

75

85

95

500V

[A]

7

12

13

22

28

30

32

43

45

60

64

75

85

690V

[A]

5

9

9

18

20

21

23

28

30

35

42

45

50

00

-

0

-

1

-

1P

2

-

-

-

3

-

UL 508 NEMA size Rated thermal current (Ith)

[A]

25

25

40

40

50

55

65

70

75

100

110

135

140

Single 115V Phase 230V

[HP]

1/2

3/4

1

2

2

2

3

3

5

5

5

7.5

10

[HP]

1.5

2

3

3

5

5

7.5

10

10

15

15

15

20

200V

[HP]

2

3

5

7.5

7.5

10

15

20

20

25

25

30

30

Three 230V Phase 460V

[HP]

3

5

7.5

10

10

15

20

25

25

30

30

40

40

[HP]

5

7.5

10

15

20

25

30

40

40

50

50

60

75

575V

[HP]

7.5

10

15

20

25

30

40

50

50

60

60

75

75

IEC947-4-1 Rated making capacity AC-3

250

Rated breaking capacity AC-3

250

200

250

200

200

Mechanical durability (M of cycles)

15

15

15

15

15

12

12

12

12

12

12

12

12

Electrical life for Ie/AC-3 max (M of cycles)

2.5

2.5

2.5

2.5

2.5

2

2

2

2

2

2

2

2

1800

1800

1800

1800

1800

1200

1200

1200

1200

1200

1200

1200

1200

Maximum cycles per hour AC control coil voltage operated contactors Weight Dimensions (W x H x D) Coil Consumption

[lbs]

0.99

2.07

4.00

[in]

1.77 x 3.27 x 3.66

2.17 X 4.17 X 4.80

2.76 X 5.51 X 5.39

Inrush [VA]

80

120

220

Holding [VA]

9

7

16

DC control coil voltage operated contactors Weight Dimensions (W x H x D) Coil Consumption

6

[lbs]

1.39

2.64

5.94

[in]

1.77 x 3.27 x 4.65

2.17 X 4.17 X 6.32

2.76 X 5.51 X 6.79

Inrush [VA]

7

9

18

Holding [VA]

7

9

18

www.westcoastpower.com 1-866-955-0888


CONTACTORS & OVERLOADS

MIRA

Overload Specifications 9~95 Amp Overloads Differential Class 10 Relay type

MTK-32

MTK-63

MTK-95

Tripping class (IEC 60947-4-1)

10

10

10

10

10

Number of poles

3

3

3

3

3

Up to 690V

Up to 690V

Up to 690V

Up to 690V

Up to 690V

690V

690V

690V

690V

690V

Rated operational voltage (Ue) Rated insulation voltage (Ui) Rated impulse voltage (Uimp) Temperature compensation °C Dimensions (W x H x D) [in]

6kV

6kV

6kV

6kV

6kV

-5 ~ 40

-5 ~ 40

-5 ~ 40

-5 ~ 40

-5 ~ 40

0.31

0.48

2.1 x 1.8 x 3.4

Weight (kg)

0.17

2.8 x 2.2 x 3.8 0.31

3.3 x 2.8 x 4.2 0.48

Functions Differential, Phase Failure

Trip Indicating

Stop

Test

Manual/Automatic Reset

Screw clamp

Screw

Lug

Screw

Lug

Terminal type

TM

NEMA Sized

2.5 Million Up to 95A

Standards Electric Life Matching UL Type F MMS Auxilary Contacts Spring Loaded Screw Terminals Safety Cover 5 Year Warranty

TM

NEMA Sized

Standards Electric Life

ALLEN BRADLEY

Matching UL Type F MMS

1.3 Million Up to 63A

Auxilary Contacts Spring Loaded Screw Terminals Safety Cover 5 Year Warranty NEMA Sized

TM

Standards Electric Life Matching UL Type F MMS

1.5 Million Up to 63A

Auxilary Contacts Spring Loaded Screw Terminals Safety Cover 5 Year Warranty *These comparisons are based on published marketing information from manufacturers. If any company or their representative notices a factual discrepancy, please contact Cerus to ensure accuracy and timely correction. Allen-Bradley and Square D are trademarks of their respective companies and these companies are not affiliates of Cerus Industrial.

7


INDUSTRIAL CATALOG

MIRA Contactors & Overload Relays Contactors

32AF Horsepower

Motor Voltage 115V

1/2

3/4

1

2

230V

1.5

2

3

3

5

200V

2

3

5

7.5

7.5

230V

3

5

7.5

10

10

460V

5

7.5

10

15

20

575V

7.5

10

15

20

25

NEMA Size

00

0

-

1

Single Phase

Three Phase

Finger safe terminals Interchangeable replacement coils Standard 1NO/1NC auxiliary contacts

2

AC Contactors

MRC-9

MRC-12

MRC-18

MRC-25

MRC-32

DC Contactors

MRD-9

MRD-12

MRD-18

MRD-25

MRD-32

Reversing Kits

MR-02

MR-02

MR-02

MR-02

MR-02

UW-32

UW-32

UW-32

UW-32

UW-32

Overload Relays

32AF

Mounts directly to MIRA contactors Differential thermal protection detects phase loss Adjustable current setting, Hand or Auto reset

Setting Range

Part Number

0.1~0.16

MTK-32/3-0.16

0.1~0.25

MTK-32/3-0.25

0.25~0.4

MTK-32/3-0.4

0.4~0.63

MTK-32/3-0.63

0.63~1

MTK-32/3-1

1~1.6

MTK-32/-3-1.6

1.6~2.5

MTK-32/3-2.5

2.5~4

MTK-32/3-4

4~6

MTK-32/3-6

5~8

MTK-32/3-8

6~9

MTK-32/3-9

7~10

MTK-32/3-10

12~18

MTK-32/3-18

16~22

MTK-32/3-22

18~25

MTK-32/3-25

22~32

MTK-32/3-32

Coil Voltage Options AC Coil Voltages DC Coil Voltages

8

Voltage

24VAC

120VAC

Frequency

50/60Hz

Voltage

12VDC

www.westcoastpower.com 1-866-955-0888

208VAC

220VAC

240VAC

277VAC

380VAC

480VAC

600VAC

50/60Hz

60Hz

50/60Hz

50/60Hz

60Hz

50/60Hz

60Hz

60Hz

24VDC

48VDC

110VDC


CONTACTORS & OVERLOADS

63AF Horsepower

95AF Horsepower

2

3

3

5

5

5

7.5

10

5

7.5

10

10

15

15

15

20

10

15

20

20

25

25

30

30

15

20

25

25

30

30

40

40

25

30

40

40

50

50

60

75

30

40

50

50

60

60

75

75

-

-

2

-

-

-

3

-

MRC-35L

MRC-40L

MRC-50L

MRC-63L

MRC-65L

MRC-75L

MRC-85L

MRC-95L

MRD-35L

MRD-40L

MRD-50L

MRD-63L

MRD-65L

MRD-75L

MRD-85L

MRD-95L

MR-02

MR-02

MR-02

MR-02

MR-02

MR-02

MR-02

MR-02

UW-63

UW-63

UW-63

UW-63

UW-95

UW-95

UW-95

UW-95

63AF

95AF

Setting Range

Part Number

Relay Setting Range

Part Number

4~6

MTK-63/3-6L

7~10

MTK-95/3-10L

5~8

MTK-63/3-8L

9~13

MTK-95/3-13L

6~9

MTK-63/3-9L

12~18

MTK-95/3-18L

7~10

MTK-63/3-10L

16~22

MTK-95/3-22L

9~13

MTK-63/3-13L

18~25

MTK-95/3-25L

12~18

MTK-63/3-18L

24~36

MTK-95/3-36L

16~22

MTK-63/3-22L

28~40

MTK-95/3-40L

18~25

MTK-63/3-25L

34~50

MTK-95/3-50L

24~36

MTK-63/3-36L

45~65

MTK-95/3-65L

28~40

MTK-63/3-40L

54~75

MTK-95/3-75L

34~50

MTK-63/3-50L

63~85

MTK-95/3-85L

45~65

MTK-63/3-65L

70~95

MTK-95/3-95L

Auxiliary Contacts Description

Part Number

Side mount

MA-1 (1NO & 1NC)

Top mount

CA-2 (Specify 2NO, 2NC, or 1NO & 1NC)

Top mount

CA-4 (Specify 4NO, 4NC, 2NO & 2NC, 3NO & 1NC, or 1NO & 3NC)

9


INDUSTRIAL CATALOG

MIRA

Accessories Replacement AC Contactor Coils Frame Size

9-32

35-63

Coil Voltage

Mechanical and Electrical Interlock

Part Number

Frame Size

Part Number

32AF~95AF

MR-02

MC9-32 240V 50/60HZ

Frame Size

Part Number

277VAC

MC9-32 277V 60HZ

32AF~63AF

AC-9

380VAC

MC9-32 380V 50/60HZ

95AF

AC-50

480VAC

MC9-32 480V 60HZ

Voltage

Part Number

24VAC

MC9-32 24V 50/60HZ

48VAC

MC9-32 48V 50/60HZ

120VAC

MC9-32 120V 50/60HZ

208VAC

MC9-32 208V 60HZ

220VAC

MC9-32 220V 50/60HZ

240VAC

Capacitor Auxiliary Units

600VAC

MC9-32 600V 60HZ

24VAC

MC35-63 24V 50/60HZ

48VAC

MC35-63 48V 50/60HZ

120VAC

MC35-63120V 50/60HZ

208VAC

MC35-63 208V 60HZ

24-48VAC

MS-1

220VAC

MC35-63 220V 50/60HZ

100-125VAC

MS-2

240VAC

MC35-63 240V 50/60HZ

200-240VAC

MS-3

277VAC

MC35-63 277V 60HZ

24-48VDC

MS-4

380VAC

MC35-63 380V 50/60HZ

100-125VDC

MS-5

MC35-63 480V 60HZ

200-220VDC

MS-6

MC35-63 600V 60HZ

24-48VAC/VDC

MS-11

100-125VAC/VDC

MS-12

200-240VAC/VDC

MS-13

380-440VAC/VDC

MS-14

480VAC 600VAC

AC/DC Surge Suppressor

Mechanical Latch Unit Voltage AC Operated Units

Replacement DC Contactor Coils Frame Size

9-32

35-63

65-95

10

Coil Voltage

Part Number

12VDC

MC9-32 12VDC

24VDC

MC9-32 24VDC

48VDC

MC9-32 48VDC

110VDC

MC9-32 110VDC

12VDC

MC35-63 12VDC

24VDC

MC35-63 24VDC

48VDC

MC35-63 48VDC

110VDC

MC35-63 110VDC

12VDC

MC65-95 12VDC

24VDC

MC65-95 24VDC

48VDC

MC65-95 48VDC

110VDC

MC65-95 110VDC

www.westcoastpower.com 1-866-955-0888

DC Operated Units

Part Number

100~127V 50/60Hz

AL-9 100VAC

200~240V 50/60Hz

AL-9 200VAC

460~500V 50/60Hz

AL-9 500VAC

100~127V 50/60Hz

AL-50 100VAC

200~240V 50/60Hz

AL-50 200VAC

460~500V 50/60Hz

AL-50 500VAC

DC24V

AL-9 24VDC

DC24V

AL-50 24VDC

DIN Rail Adapters Frame Size

Part Number

32AF

UZ-32

63AF

UZ-63/L

63AF

UZ-63/S

95AF

UZ-95/L

95AF

UZ-95/S


ORION Contactors and Overloads Installs in Minutes, Lasts a Lifetime

100~800 Amp Rated Models High Reliability: Up to 25 Million Cycles Superior Value Our Contactors Are Among the Highest Rated in the Industry for UL Sizes. 5-Year Warranty

“We like the flexibility of Orion contactors. Their universal coils are unique because they accept a wide range of voltages – I don’t have to stock a bunch of different sized coils.”


INDUSTRIAL CATALOG

ORION

Contactor Specifications 100~800 Amp Contactors Wide Range, Common Coils (AC & DC)

NEMA Sized

Quiet, Reliable Switching For Tough Applications

Long-term reliability thanks to large contact surface areas, advanced metallurgy and oversized magnetics Among the highest current ratings in the industry for UL sizes Heavy -duty construction eliminates buzzing and poor switching Electronic coil reduces in-rush and holding current, integrates protective surge suppression and prevents coil failures due to mechanical faults.

Reduced Inventory Carrying Costs Pre-installed auxiliary contacts included standard with each contactor (2NO & 2NC) Wide voltage range AC/DC coil reduces inventory and offers flexible installation solutions

Frame Size

100AF

Model

CRC-100

Number of poles Rated operational voltage, Ue

150AF

CRC-125

CRC-150

220AF CRC-180

400AF

CRC-220

CRC-300

600AF

CRC-400

CRC-600

CRC-800

3

3

3

3

3

690V

690V

690V

690V

690V

Rated operational current Ie (θ≤ 55 °C) AC-1 AC-3

Ue max 690V

[A]

150

150

200

230

260

350

420

660

900

200/240V

[A]

105

125

150

180

250

300

400

630

800

380/440V

[A]

105

120

150

180

250

300

400

630

800

500V/550V

[A]

85

90

140

180

200

250

350

500

720

690V

[A]

65

70

100

120

150

220

300

420

630

-

-

4

-

-

5

-

6

-

[A]

160

160

210

230

275

350

450

660

900

[HP]

7.5

10

15

15

15

-

-

-

-

UL 508 NEMA size Rated thermal current (Ith) Single Phase

Three Phase

115V 230V

[HP]

15

20

25

30

40

-

-

-

-

200V

[HP]

30

40

40

60

60

100

125

150

250

230V

[HP]

30

40

50

60

75

100

150

200

300

460V

[HP]

60

75

100

125

150

200

300

400

600

575V

[HP]

60

75

100

125

150

200

300

400

600

AC/DC control coil voltage operated contactors Weight Dimensions (W x H x D) Coil Consumption

12

[lbs]

6.7

7.9

13.5

22

52

[in]

3.9 x 6.5 x 5.8

4.7 x 6.9 x 6.2

5.4 x 8.0 x 7.1

6.4 x 9.6 x 7.8

11.2 x 12.3 x 9.5

Inrush [VA]

220

393

1000

Holding [VA]

9.1

14

17

www.westcoastpower.com 1-866-955-0888


CONTACTORS & OVERLOADS

ORION

Overload Specifications 100~800 Amp Overloads Differential Class 10

Thermal Overload Options

Mounts directly to contactor or standalone (screw mount) Overload includes NO & NC trip contacts Differential phase failure protection Ambient compensated (-5º to 40ºC)

Easy Installation Thermal overload relays matched for simple, direct connection with busbars Standard 1NO & 1NC auxiliary contacts on each overload relay Optional finger-proof safety covers

Frame Size

CTK-100

CTK-150

CTK-220

CTK-400

CTK-600

Tripping class (IEC 60947-4-1)

10

10

10

10

10

Number of poles

3

3

3

3

3

Up to 690V

Up to 690V

Up to 690V

Up to 690V

Up to 690V

690V

690V

690V

690V

690V

Rated operational voltage (Ue) Rated insulation voltage (Ui) Rated impulse voltage (Uimp)

6kV

6kV

6kV

6kV

6kV

-5 ~ 40

-5 ~ 40

-5 ~ 40

-5 ~ 40

-5 ~ 40

1.4

1.8

5.9

7

30

Differential, Phase Failure

Trip Indicating

Stop

Test

Temperature compensation °C Weight [lbs] Functions

Manual/Automatic Reset Terminal type

Screw

Screw

Screw

Screw

Screw

13


INDUSTRIAL CATALOG

ORION Contactors & Overload Relays Contactors

100AF

150AF

220AF

400AF

800AF

HP

HP

HP

HP

HP

Motor Voltage

100 100 200 200 5

125 150 300 300

150 200 400 400 6

200 300 600 600

CRC-220

CRC-300

CRC-400

CRC-600

CRC-800

AJ-220

AJ-220

AJ-400

AJ-400

AJ-600

AJ-600

AR-100

AR-180

AR-180

AR-180

AR-180

AR-600

AR-600

CRC-150R

CRC-220R

CRC-220R

CRC-400R

CRC-400R

-

-

115V

7.5

10

15

15

16

230V

15

20

25

30

40

200V

30

40

40

60

60

230V

30

40

50

60

75

460V

60

75

100

125

150

575V

60

75

100

125

150

CRC-100

CRC-125

CRC-150

CRC-180

Contactor Lug Kits*

AJ-125

AJ-125

AJ-150

Reversing Kits*

AR-100

AR-100 CRC-100R

Single Phase

Three Phase

NEMA Size AC/DC Contactors

4

CRC-100R

Overload Relays

100AF

150AF

220AF

400AF

Setting Range

Part Number

34-50

CTK-100/3-50

CTK-150/3-50

39-57

CTK-100/3-57

CTK-150/3-57

43-65

CTK-100/3-65

CTK-150/3-65

54-80

CTK-100/3-80

CTK-150/3-80

65-100

CTK-100/3-100

CTK-150/3-100

CTK-220/3-100

85-125

CTK-100/3-125

CTK-150/3-125

CTK-220/3-125

CTK-400/3-125

CTK-150/3-150

-

-

100-160

CTK-220/3-160

CTK-400/3-160

120-180

CTK-220/3-180

CTK-400/3-180

160-240

CTK-220/3-240

CTK-400/3-240

100-150

220-300

CTK-400/3-300

260-400

CTK-400/3-400

800AF

200-300

CTK-600/3-300

260-400

CTK-600/3-400

400-600

CTK-600/3-600

520-800

CTK-600/3-800

*Products ship disassembled. ‥For 4-Pole configurations consult factory.

Reversing assemblies are easy with the Orion Series Reversing Kit which includes adapter plate and mechanical interlock.

14

www.westcoastpower.com 1-866-955-0888


CONTACTORS & OVERLOADS

ORION

Accessories Latching Units AC Coil Operated Units

Surge Suppressors Voltage

Part Number

0~48VAC/DC

AS-11

AL-100 100VAC

48~120VAC/DC

AS-12

AL-100 200VAC

120~240VAC/DC

AS-13

Voltage

Frame Size

Part Number

100~127V 50/60Hz

100AF

200~240V 50/60Hz

100AF

460~550V 50/60Hz

100AF

AL-100 500VAC

100~127V 50/60Hz

150AF

AL-150 100VAC

200~240V 50/60Hz

150AF

AL-150 200VAC

460~550V 50/60Hz

150AF

AL-150 500VAC

100~127V 50/60Hz

220AF

AL-180 100VAC

200~240V 50/60Hz

220AF

AL-180 200VAC

460~550V 50/60Hz

220AF

AL-180 500VAC

100~127V 50/60Hz

400AF

AL-400 100VAC

200~240V 50/60Hz

400AF

AL-400 200VAC

460~550V 50/60Hz

400AF

AL-400 500VAC

DC Coil Operated Units Voltage

Frame Size

Part Number

DC24V

100AF

AL-100 24VDC

DC24V

150AF

AL-150 24VDC

DC24V

220AF

AL-180 24VDC

DC24V

400AF

AL-400 24VDC

Terminal Cover Units Frame Size

Part Number

100AF

AP-100/125

150AF

AP-150

220AF

AP-180/220

400AF

AP-300/400

600AF

AP-600/800

100AF

APT-100

150AF

APT-150

220AF

APT-220

400AF

APT-400

600AF

APT-600

Replacement Contactor Coils Voltage

Frame Size

24-25V

100AF & 150AF

CRC150C-24V

Part Number

100-240V

100AF & 150AF

CRC150C-100-200V

440-575V

100AF & 150AF

CRC150C-500V*

24-25V

220AF

CRC220C-24V

100-240V

220AF

CRC220C-100-200V

440-575V

220AF

CRC220C-500V*

100-240V

400AF

CRC400C-100-200V

440-575V

400AF

CRC400C-500V*

100-127V

600AF

CRC800C-100V

200-240V

600AF

CRC800C-200V

440-575V

600AF

CRC800C-500V*

The Orion contactor’s standard electronic coil accepts either AC or DC voltages.

*AC Coil Voltage only

15


MIRA Manual Motor Starters The OEM Solution for Motor Controls Compact Design High Interruption Capacity Reduces Overall Installed Cost 32~100 Amp Frame Sizes

The Cerus MMS insulated busbar system allows you to feed several modular circuit breakers on a standard mounting rail.


“We saved money and space by installing Cerus Manual Motor Starters which eliminated costly fuse blocks for branch protection in our multimotor control panels.”

Up to 100,000 Amps Short Circuit Interrupting Current Rating Available in Standard & High-Break Versions Lockable Handle Operator and Finger Safe Terminals Exceeds UL Standards for Group and Combination Motor Applications (UL Type E & F Ratings with Cerus MIRA Contactors) Universal Accessories Reduce Inventory Optional Waterproof Enclosure Quality Design Carefully engineered to improve reliability, the advanced flexibility of MIRA components allow for seamless integration with Cerus’ Manual Motor Starters (MMS) and accessories. With coordinated ratings as a combination starter meeting both UL and IEC Type 2 standards, the MIRA design provides an unbeatable combination reducing installation costs and saving valuable panel space. High Reliability Only contactors and breakers tested to UL standards as a unit can achieve the highest coordinated interrupt ratings. Cerus MMS carry UL Type E and F ratings when paired with MIRA contactors meeting standards for both group motor protection and self-protection when used as a combination starter.

Easy Mounting Accessories Cerus MMS have a full range of optional accessories including base plates, auxiliary contacts, alarm switches, shunts and under voltage releases. The simplified mounting of the Cerus MMS allows for fast and easy integration with bus bars and MIRA contactors.


INDUSTRIAL CATALOG

Manual Motor Starters

CMS-32S

32~100 Amp Frame Sizes Standard & High Break Adjustable Thermal or Magnetic Trip

Thermal Magnetic Rated Release Release Operational Adjustment Operating Current (A) Range (A) Current (A)

32 AF Manual Motor Starters 0.16 0.1-0.16 2.1 0.25 0.16-0.25 3.3 0.4 0.25-0.4 5.2 0.63 0.4-0.63 8.2 1 0.63-1 13 1.6 1-1.6 20.8 2.5 1.6-2.5 32.5 4 2.5-4 52 6 4-6 78 8 5-8 104 10 6-10 130 13 9-13 169 17 11-17 221 22 14-22 286 26 18-26 338 32 22-32 416 63 AF Manual Motor Starters 10 6-10 130 13 9-13 169 17 11-17 221 22 14-22 286 26 18-26 338 32 22-32 416 40 28-40 520 50 34-50 650 63 45-63 819 100 AF Manual Motor Starters 17 11-17 221 22 14-22 286 26 18-26 338 32 22-32 416 40 28-40 520 50 34-50 650 63 45-63 819 75 55-75 975 90 70-90 1170 100 80-100 1300

CMS-32H

H=3.70”

H=3.70”

D=2.95”

D=5.69”

W=1.77”

W=2.17”

Standard Trip‡

Horsepower Three Phase

SCIC (kA)*

Part Number

115V

230V

200V

230V

460V

575V

240V kA

480V kA

600V kA

1/8 1/4 1/3 1/2 1/2 1 1.5 2 2

1/10 1/6 1/3 1/2 1 1.5 2 3 3 3 5

1/2 3/4 1 2 2 3 3 5 7.5 7.5

1/2 3/4 1.5 2 3 3 5 7.5 7.5 10

3/4 1 2 3 5 5 7.5 10 15 15 20

1/2 3/4 1.5 3 5 5 7.5 10 15 20 20 30

100 100 100 100 100 100 100 100 100 100 50 50 40 30 30 20

50 50 50 50 50 50 50 50 25 25 10 10 10 10 7.5 7.5

10 10 10 10 10 10 10 5 5 5 5 5 5 5 5 5

CMS-32S-0.16 CMS-32S-0.25 CMS-32S-0.4 CMS-32S-0.63 CMS-32S-1 CMS-32S-1.6 CMS-32S-2.5 CMS-32S-4 CMS-32S-6 CMS-32S-8 CMS-32S-10 CMS-32S-13 CMS-32S-17 CMS-32S-22 CMS-32S-26 CMS-32S-32

1/2 1/2 1 1.5 2 2 3 3 5

1.5 2 3 3 3 5 7.5 10 10

2 3 3 5 7.5 7.5 10 15 20

3 3 5 7.5 7.5 10 10 15 20

5 7.5 10 15 15 20 30 30 40

7.5 10 15 20 20 30 30 40 60

100 100 100 100 100 100 100 100 100

50 50 40 40 40 40 40 40 40

10 10 10 10 10 10 10 10 10

CMS-63S-10 CMS-63S-13 CMS-63S-17 CMS-63S-22 CMS-63S-26 CMS-63S-32 CMS-63S-40 CMS-63S-50 CMS-63S-63

1 1.5 2 2 3 3 5 5 7.5 10

3 3 3 5 7.5 10 10 15 20 20

3 5 7.5 7.5 10 15 20 20 25 30

5 7.5 7.5 10 10 15 20 25 30 30

10 15 15 20 30 30 40 50 60 75

15 20 20 30 30 40 60 60 75 100

100 100 100 100 100 100 100 100 100 100

50 50 50 50 50 50 40 40 40 40

10 10 10 10 10 10 10 10 10 10

CMS-100S-17 CMS-100S-22 CMS-100S-26 CMS-100S-32 CMS-100S-40 CMS-100S-50 CMS-100S-63 CMS-100S-75 CMS-100S-90 CMS-100S-100

* UL ratings for combination manual motor controller with Cerus Mira contactors. ‡ CMS-32S are UL listed as a manual motor controller only, and are not UL Type E, manual self-protected combination motor controller.

18

H=5.51”

D=3.90”

W=1.77”

Single Phase

CMS-63H

www.westcoastpower.com 1-866-955-0888


MANUAL MOTOR STARTERS

CMS-100H

Differential Class 10 Thermal Overload Phase Failure Protection Ambient Temperature Compensation

H=6.50” D=6.73” W=2.76”

High Break Trip SCIC (kA)

Magnetic Trip Only Part Number

Part Number

240V kA

480V kA

600V kA

100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100

65 65 65 65 65 65 65 65 65 65 65 65 30 30 30 30

25 25 25 25 25 25 25 25 25 25 25 25 10 10 10 10

CMS-32H-0.16 CMS-32H-0.25 CMS-32H-0.4 CMS-32H-0.63 CMS-32H-1 CMS-32H-1.6 CMS-32H-2.5 CMS-32H-4 CMS-32H-6 CMS-32H-8 CMS-32H-10 CMS-32H-13 CMS-32H-17 CMS-32H-22 CMS-32H-26 CMS-32H-32

CMS-32HI-0.16 CMS-32HI-0.25 CMS-32HI-0.4 CMS-32HI-0.63 CMS-32HI-1 CMS-32HI-1.6 CMS-32HI-2.5 CMS-32HI-4 CMS-32HI-6 CMS-32HI-8 CMS-32HI-10 CMS-32HI-13 CMS-32HI-17 CMS-32HI-22 CMS-32HI-26 CMS-32HI-32

100 100 100 100 100 100 100 100 100

65 65 50 50 50 50 50 50 50

25 25 10 10 10 10 10 10 10

CMS-63H-10 CMS-63H-13 CMS-63H-17 CMS-63H-22 CMS-63H-26 CMS-63H-32 CMS-63H-40 CMS-63H-50 CMS-63H-63

CMS-63HI-10 CMS-63HI-13 CMS-63HI-17 CMS-63HI-22 CMS-63HI-26 CMS-63HI-32 CMS-63HI-40 CMS-63HI-50 CMS-63HI-63

100 100 100 100 100 100 100 100 100 100

65 65 65 65 65 65 50 50 50 50

25 20 20 20 20 20 10 10 10 10

CMS-100H-17 CMS-100H-22 CMS-100H-26 CMS-100H-32 CMS-100H-40 CMS-100H-50 CMS-100H-63 CMS-100H-75 CMS-100H-90 CMS-100H-100

CMS-100HI-17 CMS-100HI-22 CMS-100HI-26 CMS-100HI-32 CMS-100HI-40 CMS-100HI-50 CMS-100HI-63 CMS-100HI-75 CMS-100HI-90 CMS-100HI-100

19


INDUSTRIAL CATALOG

Manual Motor Starter Accessories MMS Auxiliaries Part Number

Description Front Auxiliary Switch

FX-1NO-1NC

Side Auxiliary Switch

LX-1NO-1NC

Magnetic Trip Alarm Switch

LAM-1NO-1NC

Any Trip Alarm Switch

LA-1NO-1NC (32AF size only)

Shunt Release

RS-(specify voltage rating using chart below)

Undervoltage Release

RU-(specify voltage rating using chart below)

Undervoltage Release with Auxiliary (2NO)

RUX-(specify voltage rating using chart below)

AC Voltage

28VAC

120VAC

260VAC

480VAC

Frequency/ Range

24V @ 50Hz 28V @ 60Hz

110-127V @ 50Hz 120V @ 60Hz

220-230V @ 50Hz 240-260V @ 60Hz

415-440V @ 50Hz 460-480V @ 60Hz

Front Auxiliary Switch Front mounting 2-pole (1NO, 1NC) One front mounting module per circuit breaker

20

Side Auxiliary Switch & Magnetic Trip Alarm Switch

Shunt Release & Undervoltage Release with Auxiliary (2NO)

Side mounting on the left 2-pole (1NO, 1NC) One side mounting module per circuit breaker (Always directly fitted to the circuit breaker except using with Any Trip Alarm Switch)

Side mounting on the right One side mounting module per circuit breaker (Always directly fitted to the circuit breaker)

www.westcoastpower.com 1-866-955-0888


MANUAL MOTOR STARTERS

Manual Motor Starter Accessories IP65 Enclosure (NEMA 4X)

Frame Size

Part Number

32AF

CI-EPH32-65S

Rugged, heavy-duty impact-resistant plastic case Rotary switch includes lockable handle for up to 3 padlocks Convenient standard knockouts for easy installation Incorporates neutral and ground busbars for easy wiring

Through the Door Operator Frame Size Shaft Length

Door i nterlocking mechanism (defeatable) Accommodates up to 3 padlocks for lockout Available in 115mm & 315mm shaft lengths

Part Number CI-MEH-32/115

32AF

115

63AF

115

CI-MEH-63/115

95AF

115

CI-MEH-100/115

32AF

315

CI-MEH-32/315

63AF

315

CI-MEH-63/315

95AF

315

CI-MEH-100/315

Frame Size

Description

Part Number

32AF

2-Position

CPB-322

63AF

2-Position

CPB-632

32AF

3-Position

CPB-323

Phase Bus Devices

Insulated bus-bar system Feed several modular circuit Reduce wiring and feed multiple manual breakers on standard mounting rails motor starters Space saving, easy installation

63AF

3-Position

CPB-633

32AF

Plastic Cover

CPBPC-32

63AF

Plastic Cover

CPBPC-63

MMS Direct Adapters & Mounting Units AC Operated Units

DC Operated Units

Direct Adapter and Mounting Unit allow complete integration of Manual Motor Starter and Contactor Reduce labor associated with wiring and mounting components

Mounting Units

Frame Size

Part Number

32AF

DA-32SA

32AF

DA-32HA

63AF

DA-63A

95AF

DA-95A

Frame Size

Part Number

32AF

DA-32SD

32AF

DA-32HD

63AF

DA-63D

95AF

DA-95D

Frame Size

Part Number

32AF

MU-45

63AF

MU-55

95AF

MU-70

21


INDUSTRIAL CATALOG

Digital Motor Protection Relays 0.5~60A Adjustable Class 1-60 LED Display

Complete Motor Protection & Monitoring

Versatile Installation

E xcellent motor protection against under/over-current, stall, phase failure, phase unbalance and phase reversal Ground fault and instantaneous short circuit options Inverse time or definite time limit selection for precise control of trip characteristics LED display indicates fault type

R emovable terminal base allows integrated display to be door-mounted with cable extension Screw or tunnel-type models available

Digital Motor Protection Relays & Accessories Specifications Wiring Connection Mounting Panel Mount Display Trip time curve Reset Display Alarm Current setting ranges Insulation resistance Surge impulse voltage (IEC1000-4-5) Trip Class Inverse trip delay Overcurrent Undercurrent Phase Failure Phase Unbalance Protective Functions Phase Reversal Stall Locked rotor Ground fault Start delay Definite Time Settings Operating delay Current Tolerance Time Voltage Operating Power Frequency Overload (2-SPST) Auxiliary Contacts Alarm (SPST) Operating Temperature Operating Storage Temperature Environment Humidity

Setting Range Screw or tunnel 35mm DIN or screw mount On unit or with cable extension Inverse curve/Definite time Manual Reset LED & Bar-graph Variable (60-110% of the setting current) 0.5-6A, 5-60A Over DC 500V 100Ω 1.2 x 50μs 6kV (apply standard wave form) Class 1-60 Adjustable 3 seconds 3 seconds 5 seconds Within 0.1 seconds 5 seconds Within 0.5 seconds 0.05~1 second 0-60 seconds 0-30 seconds ±5% ±5% (or ±0.5 sec.) AC 110-120V 60Hz (50Hz) 3A/250VAC resistive load 3A/250VAC resistive load -25° ~ 60°C -30° ~ 70°C 30-90% Relative Humidity (non-condensing)

Connection

Part Number*

0.5-6A

Screw Terminals

CDP06-S

5-60A

Screw Terminals

CDP60-S

0.5-6A

Tunnel

CDP06-T

5-60A

Tunnel

CDP60-T

DMPR Accessories Description

Part Number* ZCT D30 (30mm opening) ZCT D50 (50mm opening)

Ground Fault Current Sensor

ZCT D65 (65mm opening) ZCT D80 (80mm opening) CDP-CABLE-1M (1 meter)

Remote Mounting Cable

CDP-CABLE-2M (2 meter) CDP-CABLE-3M (3 meter)

* For ground fault detection, part number is followed with “Z” and requires a current sensor selected from table above.

Under current

Reverse phase

Phase fall

Ground fault

Stall

Short circuit

Lock

Fault conditions are clearly displayed on the DMPR’s 7-segment LED interface.

22

www.westcoastpower.com 1-866-955-0888


RELAYS, OVERLOADS, MINI CONTACTORS

Electronic Overloads 0.3~80A Adjustable Class 1-30 Microprocessor Based

Phase Protection

Specifications Wiring Connection Mounting Trip time curve Reset

P hase current unbalance: trips within 5 seconds when the phase current unbalance exceeds 50% Phase loss/phase failure: trips within 3 seconds when phase current is 70% unbalanced Phase reversal: trips within 1 second in the event of reverse phase current or mis-wiring Wide range current adjustment and Class1-30 adjustment fits any application

Display Trip Class

Protective Functions

Easy Installation Tolerance

Mounts to 35mm DIN-Rail through screw terminals and tunnel type terminal in single unit

Operating Power

Fully Adjustable Overload Relay Three models cover ¼ HP to 60 HP for reduced stocking and flexibility 1-5A range can be used with external CTs to cover applications over 80A Built-in stall protection provides maximum protection to the motor (trips at 170% of full load amps at 3 seconds)

Auxiliary Contacts Operating Environment

Current setting ranges Inverse trip delay Overcurrent Phase Failure Phase Unbalance Phase Reversal Stall Current Time Voltage Frequency Contact Ratings Operation Operating Temperature Storage Temperature Humidity

Screw, tunnel or pin 35mm DIN, screw or direct Inverse curve Manual Reset Trip LED indicator 0.3-80A, Model specific Class 1-30 Adjustable 3 seconds 5 seconds Optional 5 seconds ±5% ±5% (or ±0.5 sec.) AC 100-260V 50Hz/60Hz 2 SPDT (when power applied) 3A/250VAC resistive load 1 N.O. & 1 N.C. -25° ~ 60°C -30° ~ 70°C 30-90% Relative Humidity (non-condensing)

Electronic Overloads Connections

Mounting

Part Number

Setting Range

Pin

Direct

CRP22-3P-

0.3-1.5A 1-5A 4.4-22A

Screw

DIN/Screw

CRP22-3S-

Tunnel

DIN/Screw

CRP22-3T-

Pin

Direct

CRP40-3P-

Screw

DIN/Screw

CRP40-3S-

Tunnel

DIN/Screw

CRP40-3T-

Screw

Direct/DIN/Screw

CRP80-3S-

Current Setting - Amp range varies based on model selected Trip Class Setting - 1 to 30 seconds LED Indicator

4-20A 8-40A 16-80A

Status Indication - Normal - Overload - Phase Unbalance Fault Indication - Overcurrent - Phase loss - Reverse phase

Test/Reset Button

23


INDUSTRIAL CATALOG

Mini-Contactors & Overloads 6~12A, 3-Pole Standard & Reversing 35mm DIN or Screw Mount

Economical, Compact & Reliable - The Perfect OEM Solution!

PLC compatible coils with lower holding current for cool operation Available thermal overloads attach without brackets Standard mounting wither with screws or on 35mm DIN rail Pre-assembled and wired reversing

Economical open starter package pre-wired for contactor coil operation Wide selection of coil voltages

Coil Voltage Options

6A~12A Mini-Contactors Rated Thermal Current 115V Motor Voltage 230V 200V 230V 460V 575V AC Contactors DC Contactors AC Reversing DC Reversing

6A

9A

12A

20 1/2 1/3 1/4 1/5 1/6 1/7 CMC-6M CMD-6M CMC-6MR CMD-6MR

20 1/2 1.5 3 3 5 10 CMC-9M CMD-9M CMC-9MR CMD-9MR

20 1 2 3 3 7.5 15 CMC-12M CMD-12M CMC-12MR CMD-12MR

Setting Range

Overload Relays

24

0.1~0.16 0.16~0.25 0.25~0.4 0.4~0.63 0.63~1 1~1.6 1.6~2.5 2.5~4 4~6 5~8 6~9 7~10 9~13 12~16

Part Number CTK-12M/3-0.16 CTK-12M/ 3-0.25 CTK-12M/ 3-0.4 CTK-12M/ 3-0.63 CTK-12M/ 3-1 CTK-12M/ 3-1.6 CTK-12M/ 3-2.5 CTK-12M/ 3-4 CTK-12M/ 3-6 CTK-12M/ 3-8 CTK-12M/ 3-9 CTK-12M/ 3-10 CTK-12M/ 3-13 CTK-12M/ 3-16

www.westcoastpower.com 1-866-955-0888

AC Voltages DC Voltages

Voltage

24VAC

120VAC

240VAC

480VAC

Frequency

50/60Hz

50/60Hz

60Hz

60Hz

Voltage

12V

24V

48V

Auxiliary Contacts Description 2-Pole Auxiliaries (Top Mount)

Part Number CA-2M (1NO, 1NC) CA-2M (2NO) CA-2M (2NC) CA-4M (2NO, 2NC)

4-Pole Auxiliaries (Top Mount)

CA-4M (3NO, 1NC) CA-4M (4NO) CA-4M (4NC)


RELAYS, OVERLOADS, MINI CONTACTORS

Mini-Contactor Control Relays 4, 6 & 8-Pole Units 16 Amp Rated Standard 44mm Size

Expandable up to 8-Pole Select DPDT, 3PDT or 4PDT variations 44mm wide Finger proof design

16A continuous current, Ith DIN rail or screw mountable AC/DC control voltage

Specifications Rated Current

Contact Ratings

AC Duty

DC Duty

Making/Braking Current

Inductive Load Resistive Load Inductive Load Resistive Load 120V

6A

10A

66A

240V

3A

8A

33A

66A 33A

480V

1.5A

5A

16.5A

16.5A

600V

2A

5A

13.2A

13.2A

125V

1.1A

5A

3.7A

-

250V

0.55A

3A

1.8A

-

440V

0.31A

2.5A

1.4A

-

600V

0.2A

1A

0.7A

-

Continuous Current, Ith

16A

Performance Operation cycle

1800 operations/hour Mechanical Durability AC15 duty

Endurance

Electrical Life

AC12 duty DC13, 12 duty

20 M operations 220V

0.5 M operations

440V

0.5 M operations

220V

0.25 M operations

440V

0.25 M operations

24~220V

0.5 M operations

Mini-Contactor Control Relays Description

Part Number

4-Pole AC Coil Relay

CMC-6M/4 (2NO, 2NC)

4-Pole DC Coil Relay

CMD-6M/4 (2NO, 2NC) CA-2M (1NO, 1NC) 6-Pole

CA-2M (2NO) CA-2M (2NC) CA-4M (1NO, 3NC)

Additional Contacts

CA-4M (2NO, 2NC) 8-Pole

CA-4M (3NO, 1NC)

Mini-contactor relays shown with additional contacts configured for multi-pole operation.

CA-4M (4NO) CA-4M (4NC)

25


MIRA Breakers

Low voltage circuit breakers High Breaking Capacity Optimum Coordination Technique Superior Overload Protection Guaranteed Short Circuit Current Ratings Wide Range of Optimized Auxiliaries and Accessories

“I have made a conscious effort to change all my breakers to the MIRA line. The solid protection and high interrupting ratings make Cerus our choice.”


High Performance

Mechanism Unit

High Interrupting Capacity

Optimum cam curve provides consistent contact force during closing and opening of the breaker resulting in excellent current limiting and superior de-bounce for longer contact life.

Arc-extinguishing Unit

Patented puffer assisted self-quenching arc chamber Greatly reduces arc voltage compared to traditional arc quenching technologies for higher interrupting performance.

Up to 65KA on high interrupting models at 480VAC. UL489 Rated IEC Listed


INDUSTRIAL CATALOG

TD/TS Series Circuit Breakers 3-Pole, 40~800 Amp Rated UL 489 Standards

Superior Technology Results in High Performance

Cerus TD and TS circuit breakers provide superior performance in a compact package, with adjustable thermal trip settings and magnetic trip settings for ultimate flexibility Advanced arc quenching technology ensures excellent trip performance and long life Standardized internal accessories are interchangeable on all models and are field or factory installed Accessories mount on right or left side to simplify panel wiring

High Interrupting Capacity Up to 65KA on high interrupting models at 480VAC

Simplified Range Common mounting depths between frames 125A~800A Four frame sizes from 40A~800A

Variety of Trip Units Available FTU - Fixed thermal & magnetic FMU- Adjustable thermal (0.8~1.0), fixed magnetic ATU - Adjustable thermal (0.8~1.0) & magnetic (0.5~1.0)

Variable Accessories

28

Electrical auxiliaries Extended rotary handle Flange handle Locking devices

www.westcoastpower.com 1-866-955-0888

High Interrupting capacity TS800HU TS400HU TS250HU

TD125HU

TS800NU TS400NU

TS250NU

TD125NU


CIRCUIT BREAKERS

Specifications TD125

TS250

TS400

TS800

125

250

400

800

40,50,60,80,100,125

160,200,250

300,400

500,600,800

3

3

3

3

600

600

600

600

Frame size (AF) Rated current (A) No. of Poles Rated operational voltage, Ue AC (V) UL interrupting rating (kA) AC 50/60Hz

NU

HU

NU

HU

NU

HU

NU

HU

240V

50

100

50

100

50

100

50

100

480V

35

65

35

65

35

65

35

65

600V

10

14

10

14

14

20

18

14

Reference standard

UL 489

UL 489

UL 489

UL 489

-

-

-

-

Trip unit (Thermal-Magnetic) • Fixed-thermal, Fixed-magnetic (FTU) • Adjustable-thermal, Fixed-magnetic (FMU

-

-

• Adjustable-thermal, Adjustable-magnetic, 3-Pole (ATU)

-

• Molded Case Switch (MCS)

-

-

-

-

Accessories AX

AL

SHT

UVT

Extended rotary handle

Mechanical life (operations)

Flange handle

4,000

5,000

5,000

5,000

Electrical life @ 600V AC (operations)

4,000

1,000

1,000

500

Weight [lbs] Dimensions (W x H x D) [in]

1.2

1.9

5.7

13.6

3.5 x 6.5 x 3.4

4.1 x 7.0 x 3.4

5.5 x 11.5 x 4.3

8.3 x 16.9 x 5.3

TD/TS Series Circuit Breakers Frame Size

125AF

250AF

400AF

800AF

Amp Rating

Thermal Trip Setting

40A

Magnetic Trip Setting

HU Series (High Interrupting)*

NU Series (Normal Interrupting)

32-40A

TD125HU FMU 125 40A

TD125NU FMU 125 40A

50A

40-50A

TD125HU FMU 125 50A

TD125NU FMU 125 50A

60A

48-60A

TD125HU FMU 125 60A

TD125NU FMU 125 60A

80A

64-80A

TD125HU FMU 125 80A

TD125NU FMU 125 80A

10X

100A

80-100A

TD125HU FMU 125 100A

TD125NU FMU 125 100A

125A

100-125A

TD125HU FMU 125 125A

TD125NU FMU 125 125A

160A

125-160A

TS250HU ATU 250 160A

TS250NU ATU 250 160A

200A

160-200A

TS250HU ATU 250 200A

TS250NU ATU 250 200A

250A

200-250A

TS250HU ATU 250 250A

TS250NU ATU 250 250A

300A

250-300A

TS400HU ATU 400 300A

TS400NU ATU 400 300A

400A

300-400A

TS400HU ATU 400 400A

TS400NU ATU 400 400A

500A

400-500A

TS800HU ATU 800 500A

TS800NU ATU 800 500A

600A

500-600A

TS800HU ATU 800 600A

TS800NU ATU 800 600A

800A

600-800A

TS800HU ATU 800 800A

TS800NU ATU 800 800A

5-10X

5-10X

5-10X

29


INDUSTRIAL CATALOG

Optimize Your Circuit Breaker Functionality Alarm Switch (AL) O utput for audio or visual indication of a tripped breaker due to overload, short-circuit, operation of shunt trip, or undervoltage trip conditions, operation of pushbutton. Useful in automated plants where operators must be signaled about changes in the electrical distribution system. Closed contact when the circuit breaker is tripped automatically. Does not function when the breaker is opened manually. Contact is open when the circuit breaker is reset.

Auxiliary Switch (AX) For applications requiring remote “ON” and “OFF” indication Contains two contacts having a common connection; one open, one closed.

Undervoltage Trip (UVT) Simplicity All TD & TS accessories fit all frame sizes of circuit breakers. Cassette style, each accessory fits into a unique slot in each breaker for an easy, trouble free, installation.

Electrical Auxiliaries

30

www.westcoastpower.com 1-866-955-0888

Automatically opens a circuit breaker when the voltage drops to a value ranging between 35% - 75% of the line voltage. The operation is instantaneous - the circuit breaker cannot be reclosed until the voltage returns to 85% of line voltage. Continuously energized, the undervoltage trip must be operating before the circuit breaker can be closed. Range of tripping voltage: 0.35 ~ 0.7Vn MCCB re-closing is possible when voltage: 0.85Vn is exceeded.

Frequency (only AC): 45Hz ~ 65Hz

Shunt Trip (SHT) O pens the mechanism in response to an externally applied voltage signal. Includes coil clearing contacts that automatically clear the signal circuit when the mechanism has tripped, to prevent coil overheating.


CIRCUIT BREAKERS

TD/TS Series Accessories

Alarm & Auxiliary Switches

Alarm Switch

Part Number

Description

AL-TD/TS

Alarm switch for TD/TS series MCCB

AX-TD/TS

Auxiliary switch for TD/TS series MCCB

Auxiliary Switch

Undervoltage Trip, UVT Part Number UVT-24V

Control Voltage

Power Consumption AC (VA)

DC (W)

mA

AC/DC 24V

0.64

0.65

27

UVT-48V

AC/DC 48V

1.09

1.10

23

UVT-120V

AC/DC 110 ~ 130V

0.73

0.75

5.8

UVT-230V

AC/DC 200 ~ 240V/DC 250V

1.21

1.35

5.4

UVT-400V

AC/DC 380 ~ 440V

1.67

-

3.8

UVT-480V

AC/DC 440 ~ 480V

1.68

-

3.5

Maximum opening time (ms)

50

Transformer operating voltage (V) - Drop (Circuit breaker trips) - Rise (Circuit breaker can be switched on)

0.7 ~ 1.35Vn ~0.85Vn

Shunt Trip, SHT Part Number SHT-12VDC

Control Voltage DC 12V

Power Consumption AC (VA)

DC (W)

mA

-

0.36

30

SHT-24V

AC/DC 24V

0.58

0.58

24

SHT-48V

AC/DC 48V

1.22

1.23

25

SHT-120V

AC/DC 110 ~ 130V

1.36

1.37

10.5

SHT-230V

AC/DC 220 ~ 240V/DC250V

1.80

1.88

7.5

SHT-480V

AC/DC 380 ~ 500V

1.15

-

2.3

Maximum opening time (ms)

50

31


INDUSTRIAL CATALOG

Extension Handles Rotary Handles UL Type

12/3R

Circuit breaker with cover frame and rotary extended handle

4X

Degree of Protection Rain, dripping water, dust

Totally protected against ingress of dust and water jets from any direction

Circuit Breaker

Part Number

TD125

EHU-1

TS250

EHU-2

TS400

EHU-3

TS800

EHU-4

TD125

EHU-1X

TS250

EHU-2X

TS400

EHU-3X

TS800

EHU-4X

Circuit Breaker

Part Number

TD125

FH-1

TS250

FH-2

TS400

FH-3

TS800

FH-4

TD125

FH-1X

TS250

FH-2X

TS400

FH-3X

TS800

FH-4X

Flange Handles UL Type

12/3R

4X

Degree of Protection Rain, dripping water, dust

Totally protected against ingress of dust and water jets from any direction

5.

1.

4.

A Full Range of Accessories 1. 2. 3. 4. 5.

32

Circuit Breaker 2. Flange handle Extended rotary handle Locking devices (Removable, Fixed) Mechanical interlock device

www.westcoastpower.com 1-866-955-0888

3.


CIRCUIT BREAKERS

Provide Security and Safety with Cerus Breakers Supports Up to 3 Padlocks

Available for all TD & TS circuit breakers Allows the handle to be locked in the “ON” and “OFF” position Locking in the OFF position guarantees isolation according to IEC 60947-2 Accommodates up to three padlocks with shackle diameters no larger than 5/16” Padlocks are not supplied

Fixed Locking Device MCCB

Function

Part Number

TD125

Lock in “OFF” or “ON” position

PHL1

TS250

Lock in “OFF” or “ON” position

PHL2

TS400

Lock in “OFF” or “ON” position

PHL3

TS800

Lock in “OFF” or “ON” position

PHL4

Guaranteed Breaker Isolation

Removable locking device is available for all TD & TS circuit breakers. The locking device is designed to be easily attached to the circuit-breaker. This device allows the handle to be locked in the “OFF” position. Locking in the “OFF” position guarantees isolation according to IEC 60947-2. A maximum of three (3) padlocks with shackle diameters ranging from 5 to 8mm may be used. Padlocks are not supplied

Removable Locking Device MCCB

Function

Part Number

TD125

“OFF” position

PL1

TS250

“OFF” position

PL2

TS400

“OFF” position

PL3

TS800

“OFF” position

PL4

Circuit Breaker Interlocks

Mechanical interlock is applied to the front of two breakers mounted side-by-side Prevents simultaneous closing of the two breakers Mounts directly on the cover of the breakers Interlocking plate allows user to lock both breakers in the OFF position or only one breaker in the OFF position A simple and effective interlock for bypass or other power transfer systems

Mechanical Interlock Frame Size

Part Number

TD125

MIT13

TS250

MIT23

TS400

MIT33

TS800

MIT43

33


Exceeding the Industrial Standard Optimize System Reliability Fast Installation Higher Reliability

“Cerus makes sure that I get the right starter for my application. They deliver when I need it and comes ready to install. Talk about service.”


From 1/2 HP to 300HP, Cerus has your starter application covered. You get time and money saving features on top of Cerus’ legendary quality and service – all backed by a 5-year contactor warranty! We don’t meet the specs – we set them! Economy Starters

MMS: Enclosed Manual Motor Starters

ISS: Industrial Start/Stop

IPS: Industrial & Pump Starter

Ranges HP ranges* Amperage ranges Starter Type

3

/4 HP - 50HP

3

/4 HP - 20HP

1HP - 300HP

1HP - 300HP

0.1A - 85A

0.1A - 32A

0.1A - 400A

0.1A - 400A

Non-reversing

Non-reversing

Non-reversing (standard), or Combination

Non-reversing (standard) or Combination

Protective Options

Bi-metallic Thermal Overload (Class 10)

Bi-metallic Thermal Overload (Class 10)

Construction

UL Type 1

UL Type 4X

Operator Options

On/Off pushbuttons available

Automation System Interface

-

* Horsepower minimum & maximum ratings are based on 460V applications

-

-

Electronic Overload (9~95A Models) Bi-metallic Thermal Overload (Class 10) (100~400A Models)

Electronic Overload Phase Fail Protection Stall Protection Locked Rotor Over/Under Voltage Power Fail Options Anti-Cycling

UL Type 1, 4, 12, 4X

UL Type 1, 4, 12, 4X

START/STOP pushbuttons

HOA/Reset Keypad Optional START/STOP pushbuttons

Remote Operator Station

Remote Operator Station Dry/Voltage Auto Input Permissive Auto Override (Fireman’s) 120VAC Control Power Transformer Damper Control & Status


INDUSTRIAL CATALOG

Enclosed Manual Motor Starter

1Ø & 3Ø, 115~600VAC, 1/10~30HP High Break Thermal Magnetic or Magnetic Trip Only Lockable Disconnect

Rugged Construction with Standard Handle Lock-out With a heavy-duty impact-resistant plastic case. IP65 rating. (UL Type 4/4X pending) Standard rotary switch includes easy provision for padlock/tag-out at no extra charge.

Superior Protection

UL listed manual motor control provides motor overload and motor circuit protection in one package - no separate circuit breaker or fuses required Both models are rated up to 100,000 Amps interrupting capacity - ensuring maximum compatibility and coordination with existing electrical installations. Meet UL Type E ratings for group motor installation with no additional branch circuit breaker or fuses required

Enclosed Manual Motor Starter Horsepower Thermal Magnetic Rated Release Release Single Phase Three Phase Operational Adjustment Operating Current (A) Range (A) Current (A) 115V 230V 230V 460V 575V 1.6

1-1.6

20.8

-

1/10

-

3/4

3/4

2.5

1.6-2.5

32.5

-

1/6

1/2

1

1/

4

2.5-4

52

1/8

1/3

3/4

2

3

6

4-6

78

1/4

1/2

11/2

3

5

8

5-8

104

1/3

1

2

5

5

10

6-10

130

1/2

11/2

3

5

71/2

13

9-13

169

1/2

2

3

71/2

10

17

11-17

221

1

3

5

10

15

22

14-22

286

1 2

1/

3

1 2

7/

15

20

26

18-26

338

2

3

71/2

15

20

32

22-32

416

2

5

10

20

30

*UL rating for manual motor controller-group ratings. Manual motor starter group ratings may vary – visit www.westcoast-

36

1 2

www.westcoastpower.com 1-866-955-0888

SCIC (kA) 240V kA

480V kA

600V kA

100 100 100 100 100 100 100 100 100 100 100

65 65 65 65 65 65 65 30 30 30 30

25 25 25 25 25 25 25 10 10 10 10

High Break Trip

Magnetic Trip Only

CIE-MMS-32H-1.6

CIE-MMS-32HI-1.6

CIE-MMS-32H-2.5

CIE-MMS-32HI-2.5

CIE-MMS-32H-4

CIE-MMS-32HI-4

CIE-MMS-32H-6

CIE-MMS-32HI-6

CIE-MMS-32H-8

CIE-MMS-32HI-8

CIE-MMS-32H-10

CIE-MMS-32HI-10

CIE-MMS-32H-13

CIE-MMS-32HI-13

CIE-MMS-32H-17

CIE-MMS-32HI-17

CIE-MMS-32H-22

CIE-MMS-32HI-22

CIE-MMS-32H-26

CIE-MMS-32HI-26

CIE-MMS-32H-32

CIE-MMS-32HI-32


ENCLOSED INDUSTRIAL STARTERS

High Value Enclosed Starter 1Ø & 3Ø, 115~600VAC, 1/10~60HP Available Start/Stop Pushbutton Option Thermal Motor Overload

Cost Effective and Reliable Start/Stop pushbutton options Metal or plastic enclosures High reliability up to 2.5 million electrical contactor cycles at full rated current* (varies by model)

Thermal overload protection Differential phase failure protection Ambient compensated (-5º to 40ºC)

Magnetic Starters - NEMA1 Plastic Enclosure with Thermal Overload & Start/Stop Pushbuttons Single Phase

Three Phase

1/10

-

-

3/4

3/4

Maximum Overload (A)

Part Number

115V 230V 200V 230V 460V 575V* CMW-9MB/K-

CMW-12MB/K-

CMW-18MB/K-

CMW-22MB/K-

1.6

1/8

1/2

1/2

1

1

CMW-9MB/K-

CMW-12MB/K-

CMW-18MB/K-

CMW-22MB/K-

2.5

1/8

1/3

3/4

3/4

2

2

CMW-9MB/K-

CMW-12MB/K-

CMW-18MB/K-

CMW-22MB/K-

4

1/4

1/2

1

1.5

3

3

CMW-9MB/K-

CMW-12MB/K-

CMW-18MB/K-

CMW-22MB/K-

6

1/3

1

2

2

5

5

CMW-9MB/K-

CMW-12MB/K-

CMW-18MB/K-

CMW-22MB/K-

9

1/2

1.5

2

3

5

5

CMW-9MB/K-

CMW-12MB/K-

CMW-18MB/K-

CMW-22MB/K-

10

1/2

2

3

3

7.5

7.5

CMW-9MB/K-

CMW-12MB/K-

CMW-18MB/K-

CMW-22MB/K-

13

1

3

3

5

10

10

CMW-9MB/K-

CMW-12MB/K-

CMW-18MB/K-

CMW-22MB/K-

18

1 .5

3

5

7.5

15

15

CMW-9MB/K-

CMW-12MB/K-

CMW-18MB/K-

CMW-22MB/K-

22

Magnetic Starters - NEMA1 Steel Enclosure with Thermal Overload

1/10

-

-

3/4

3/4

CMW-9

CMW-12

CMW-22

B/K

/K

Maximum Overload Amps 1.6

1/8

1/2

1/2

1

1

CMW-9

CMW-12

CMW-22

B/K

/K

2.5

1/8

1/3

3/4

3/4

2

2

CMW-9

CMW-12

CMW-22

B/K

/K

4

1/4

1/2

1

1.5

3

3

CMW-9

CMW-12

CMW-22

CMW-40

B/K

/K

6

1/3

1

2

2

5

5

CMW-9

CMW-12

CMW-22

CMW-40

B/K

/K

9

1/2

1.5

2

3

5

5

CMW-12

CMW-22

CMW-40

B/K

/K

10

1/2

2

3

3

7.5

7.5

CMW-12

CMW-22

CMW-40

B/K

/K

13

1

3

3

5

10

10

CMW-12

CMW-22

CMW-40

B/K

/K

18

Single Phase 115V

230V

Three Phase 200V

Part Number

230V 460V 575V*

Start/ Stop

Base

1 .5

3

5

7.5

15

15

CMW-22

CMW-40

CMW-50

CMW-85

B/K

/K

22

2

3

7.5

7.5

15

20

CMW-22

CMW-40

CMW-50

CMW-85

B/K

/K

26

3

5

7.5

10

20

25

CMW-40

CMW-50

CMW-85

B/K

/K

36

3

5

10

10

25

25

CMW-40

CMW-50

CMW-85

B/K

/K

40

3

7.5

10

10

30

30

CMW-50

CMW-85

B/K

/K

50

3

7.5

15

15

30

40

CMW-50

CMW-85

B/K

/K

65

5

10

20

20

40

50

CMW-85

B/K

/K

75

7.5

15

20

25

50

60

CMW-85

B/K

/K

85

*Visit www.westcoastpower.com for warranty terms. Contactor ratings vary by model.

37


INDUSTRIAL CATALOG

ISS

Industrial Start/Stop

1Ø & 3Ø, 115~600VAC, 1–300HP Start/Stop Pushbuttons Superior Electronic Motor Protection

NEMA Sized

Proven Reliability for Demanding Industrial Applications Everything You Need is Standard

Start/Stop pushbutton control with terminals for remote 3-wire operator station Multi-tap control power transformer accepts all common motor voltages Solid-state electronic overload relay (Up to NEMA Size 3) Lockable cover prevents tampering

Quality Construction UL 508A Listed NEMA size rated contactors 5-Year warranty

Superior Motor Overload Protection

Phase loss and phase imbalance protection Ambient compensated (-5º to 40ºC) Manual Reset Trip-free design

Wide range electronic overload eliminates sizing call backs.

Combination Versions Include Disconnect

Motor Circuit Protector disconnect provides branch and short circuit protection High interrupting ratings for maximum electrical system compatibility No fuses or breakers required - save time and money Lockable through the door handle for safety

Easy Installation with Fewer Call Backs

38

F lexible sizing makes ordering easy UL Type 1 enclosure includes top and bottom knock-outs Mount more starters in less space with our slim line case High reliability...up to 2.5 million contactor electrical cycles at full rated current

www.westcoastpower.com 1-866-955-0888

Our lockable disconnect provides superior protection without costly fuses.


ENCLOSED INDUSTRIAL STARTERS

Specifications Starter Type Industrial Starter Standard or Combination UL Type 1, UL Type 4/12, UL Type 4X (Stainless or Fiberglass) User Interface Start / Stop Pushbuttons Standard Control Operations 3-Wire

Terminal block provision for remote Start/Stop

Protective Functions (9~95A Models) Overload Type Electronic; I2t Thermal Trip Curve

Simple and clearly indicated Start/Stop operation.

Trip Class Class 1-30 Reset Manual Phase Unbalanced Trip within 3 seconds @ 70% unbalance Phase Loss Trip within 3 seconds Stall Trip within 3 seconds @ 170% FLA Protective Functions (100~400A Models) Overload Type Thermal bi-metallic Trip Class Class 10 (100~800A) Reset Manual Phase Loss Differential overload protection

Provided terminal blocks allow for connection to remote Start/Stop station.

Mechanical Enclosure types

UL Type 1 or UL Type 4/12

Environmental Ambient Operating Temp -5° to 140° F (-20° to 60° C) Ambient Storage Temp -5° to 185° F (-20° to 85° C) Relative Humidity 5% to 95% non-condensing

Compact & Rugged UL Type 1 Model R eady for indoor installations with conduit knockouts and mounting flanges Same-day shipping available up to NEMA Size 1

39


INDUSTRIAL CATALOG

ISS Ordering and Sizing Information

Standard Start/Stop pushbuttons Enclosure types for all environments Provision for remote operator station Combination version features motor circuit protector to provide branch and short circuit protection

Options Part Number

Description

ISS-RST

Front Mounted Reset Pushbutton

ISS-TBC

Terminal Control Only

ISS-1PH

Wiring for Single Phase Motor

Standard Magnetic Starters 9~95A - Electronic Overload Horsepower Single Phase

Three Phase

115V 230V 200V 230V 460V 575V*

SCIC KAIC NEMA @460V Size

UL Type 1

UL Type 4/12

UL Type 4X Fiberglass

UL Type 4X Stainless

1/6

1/2

1

1.5

3

3

5

00

ISS1-9/J-5

ISS12-9/J-5

ISSXF-9/J-5

ISSXS-9/J-5

1

3

5

5

10

15

5

0

ISS1-18/J-22

ISS12-18/J-22

ISSXF-18/J-22

ISSXS-18/J-22

2

5

7.5

10

20

25

5

1

ISS1-32/J-40

ISS12-32/J-40

ISSXF-32/J-40

ISSXS-32/J-40

3

10

20

20

40

50

5

2

ISS1-50/J-80

ISS12-50/J-80

ISSXF-50/J-80

ISSXS-50/J-80

5

15

30

40

60

60

10

3

-

ISS12-85/J-80

ISSXF-85/J-80

ISSXS-85/J-80

UL Type 4/12

UL Type 4X Fiberglass

UL Type 4X Stainless

Combination Magnetic Starters 9~95A - Electronic Overload Horsepower Single Phase

Three Phase

115V 230V 200V 230V 460V 575V*

40

*SCIC NEMA KAIC @460V Size

UL Type 1

-

1/10

-

-

3/4

3/4

65

00

ISS1-9/ J-G1.6-5

ISS12-9/J-G1.6-5

ISSXF-9/J-G1.6-5

ISSXS-9/J-G1.6-5

-

1/6

1/2

1/2

1

1.5

65

00

ISS1-9/J-G2.5-5

ISS12-9/J-G2.5-5

ISSXF-9/J-G2.5-5

ISSXS-9/J-G2.5-5

1/8

1/3

3/4

3/4

2

3

65

00

ISS1-9/J-G4-5

ISS12-9/J-G4-5

ISSXF-9/J-G4-5

ISSXS-9/J-G4-5

1/6

1/2

1

1.5

3

3

65

00

ISS1-9/J-G6-5

ISS12-9/J-G6-5

ISSXF-9/J-6-5

ISSXS-9/J-6-5

1/3

1

2

2

5

5

65

0

ISS1-18/J-G8-22

ISS12-18/J-G8-22

ISSXF-18/J-G8-22

ISSXS-18/J-G8-22

1/2

1.5

2

3

5

7.5

65

0

ISS1-18/J-G10-22

ISS12-18/J-G10-22

ISSXF-18/J-G10-22

ISSXS-18/J-G10-22 ISSXS-18/J-G13-22

1/2

2

3

3

7.5

10

65

0

ISS1-18/J-G13-22

ISS12-18/J-G13-22

ISSXF-18/J-G13-22

1

3

3

5

10

15

30

0

ISS1-18/J-G17-22

ISS12-18/J-G17-22

ISSXF-18/J-G17-22

ISSXS-18/J-G17-22

1.5

3

5

7.5

15

20

30

1

ISS1-32/J-G22-40

ISS12-32/J-G22-40

ISSXF-32/J-G22-40

ISSXS-32/J-G22-40

2

3

7.5

7.5

15

20

30

1

ISS1-32/J-G26-40

ISS12-32/J-G26-40

ISSXF-32/J-G26-40

ISSXS-32/J-G26-40

ISS1-32/J-G32-40

2

5

7.5

10

20

25

30

1

ISS12-32/J-G32-40

ISSXF-32/J-G32-40

ISSXS-32/J-G32-40

3

7.5

10

10

30

30

50

2

-

ISS12-50/J-G40-40

ISSXF-50/J-G40-40

ISSXS-50/J-G40-40

3

10

15

15

40

40

50

2

-

ISS12-50/J-G50-80

ISSXF-50/J-G50-80

ISSXS-50/J-G50-80

5

10

20

20

50

50

50

3

-

ISS12-85/J-G63-80

ISSXF-85/J-G63-80

ISSXS-85/J-G63-80

5

15

20

25

60

60

50

3

-

ISS12-85/J-G75-80

ISSXF-85/J-G75-80

ISSXS-85/J-G75-80

www.westcoastpower.com 1-866-955-0888


ENCLOSED INDUSTRIAL STARTERS

Standard Start/Stop pushbuttons Enclosure types for all environments Provision for remote operator station Combination version features molded case circuit breaker to provide branch and short circuit protection

Standard Magnetic Starters 100~400A - Thermal Overload Horsepower Three Phase 200V 230V 460V 575V*

SCIC KAIC NEMA @460V Size

UL Type 4/12

UL Type 4X Fiberglass

UL Type 4X Stainless

40

40

75

75

10

-

ISS12-125/K-125

ISSXF-125/K-125

ISSXS-125/K-125

40

50

100

100

10

4

ISS12-150/K-150

ISSXF-150/K-150

ISSXS-150/K-150

60

75

150

150

10

-

ISS12-220/K-220

ISSXF-220/K-220

ISSXS-220/K-220

100

100

200

200

18

5

ISS12-300/K-300

ISSXF-300/K-300

ISSXS-300/K-300

125

150

300

300

18

-

ISS12-400/K-400

ISSXF-400/K-400

ISSXS-400/K-400

Combination Magnetic Starters 100~400A -Thermal Overload Horsepower Three Phase 200V 230V 460V 575V*

SCIC KAIC NEMA @460V Size

UL Type 4/12

UL Type 4X Fiberglass

UL Type 4X Stainless

40

40

75

75

10

-

ISS12-125/K-G-125

ISSXF-125/K-G-125

ISSXS-125/K-G-125

40

50

100

100

10

4

ISS12-150/K-G-150

ISSXF-150/K-G-150

ISSXS-150/K-G-150

60

75

150

150

10

-

ISS12-220/K-G-220

ISSXF-220/K-G-220

ISSXS-220/K-G-220

100

100

200

200

18

5

ISS12-300/K-G-300

ISSXF-300/K-G-300

ISSXS-300/K-G-300

125

150

300

300

18

-

ISS12-400/K-G-400

ISSXF-400/K-G-400

ISSXS-400/K-G-400

* For 600V part numbers please consult factory. ++ For starters over NEMA Size 3 consult factory.

41


INDUSTRIAL CATALOG

Industrial Starters

1Ø & 3Ø, 115~600VAC, 1–200HP Wye-Delta & Reversing Models Optional Control Features

NEMA Sized

Enclosed Wye-Delta Starters

Standard timer ensures smooth transition between start & run operations Each starter includes a control power transformer and Hand/Off/Auto switch Ambient temperature compensated differential bi-metallic thermal overload protection Terminal block connection for remote operation Optional molded case circuit breaker disconnect provides branch and short circuit protection Disconnect features high interrupting ratings for maximum electrical system compatibility 5-Year contactor warranty

Enclosed Wye-Delta, Open Transition Horsepower

UL Type 4/12 Standard

230V

460V

20

20

40

CIE12-50/DW

CIE12-50/DW-G

40

40

60

CIE12-85/DW

CIE12-85/DW-G

50

50

125

CIE12-125/DW

CIE12-125/DW-G

60

60

125

CIE12-150/DW

CIE12-150/DW-G

125

125

200

CIE12-220/DW

CIE12-220/DW-G

150

150

300

CIE12-300/DW

CIE12-300/DW-G

200

200

400

CIE12-400/DW

CIE12-400/DW-G

Options Part Number

42

UL Type 4/12 Combination

208V

Description

STR-RPL

Run pilot light (Red Standard)

STR-RST

Door mounted Reset pushbutton

STR-OFF

Off pilot light (Green Standard)

STR-STP

Emergency stop pushbutton (40mm, push-pull)

STR-1PH

Wiring for Single Phase Motor

www.westcoastpower.com 1-866-955-0888


ENCLOSED INDUSTRIAL STARTERS

Enclosed Reversing Starters

Each starter includes a control power transformer and terminal block connections Easily integrate remote user controls such as pendant stations or switch/pushbutton operators Solid-state electronic overload relay provides phase loss and stall protection Optional motor circuit protector (MCP) disconnect provides branch and short circuit protection Disconnect features high interrupting ratings for maximum electrical system compatibility Options for user selected local control methods 5-Year contactor warranty

Industrial Reversing Starters 9~95A - Electronic Overload Horsepower Single Phase

Three Phase

115V 230V 200V 230V 460V 575V*

SCIC KAIC NEMA @460V Size

UL Type 4/12

UL Type 4X Fiberglass

UL Type 4X Stainless

1/6

1/2

1

1.5

3

3

5

00

CIE12-9/R-5

CIEXF-9/R-5

CIEXS-9/R-5

1

3

5

5

10

15

5

0

CIE12-18/R-22

CIEXF-18/R-22

CIEXS-18/R-22

2

5

7.5

10

20

25

5

1

CIE12-32/R-40

CIEXF-32/R-40

CIEXS-32/R-40

3

10

20

20

40

50

5

2

CIE12-50/R-80

CIEXF-50/R-80

CIEXS-50/R-80

5

15

30

40

60

60

10

3

CIE12-85/R-80

CIEXF-85/R-80

CIEXS-85/R-80

Industrial Combination Reversing Starters 9~95A - Electronic Overload Horsepower Single Phase

Three Phase

115V 230V 200V 230V 460V 575V*

SCIC KAIC NEMA @460V Size

UL Type 4/12

UL Type 4X Fiberglass

UL Type 4X Stainless

-

1/10

-

-

3/4

3/4

65

00

CIE12-9/R-G1.6-5

CIEXF-9/R-G1.6-5

CIEXS-9/R-G1.6-5

-

1/6

1/2

1/2

1

1.5

65

00

CIE12-9/R-G2.5-5

CIEXF-9/R-G2.5-5

CIEXS-9/R-G2.5-5

1/8

1/3

3/4

3/4

2

3

65

00

CIE12-9/R-G4-5

CIEXF-9/R-G4-5

CIEXS-9/R-G4-5

1/6

1/2

1

1.5

3

3

65

00

CIE12-9/R-G6-5

CIEXF-9/R-G6-5

CIEXS-9/R-G6-5

1/3

1

2

2

5

5

65

0

CIE12-18/R-G8-22

CIEXF-18/R-G8-22

CIEXS-18/R-G8-22

1/2

1.5

2

3

5

7.5

65

0

CIE12-18/R-G10-22

CIEXF-18/R-G10-22

CIEXS-18/R-G10-22

1/2

2

3

3

7.5

10

65

0

CIE12-18/R-G13-22

CIEXF-18/R-G13-22

CIEXS-18/R-G13-22

1

3

3

5

10

15

30

0

CIE12-18/R-G17-22

CIEXF-18/R-G17-22

CIEXS-18/R-G17-22

1.5

3

5

7.5

15

20

30

1

CIE12-32/R-G22-40

CIEXF-32/R-G22-40

CIEXS-32/R-G22-40

2

3

7.5

7.5

15

20

30

1

CIE12-32/R-G26-40

CIEXF-32/R-G26-40

CIEXS-32/R-G26-40

2

5

7.5

10

20

25

30

1

CIE12-32/R-G32-40

CIEXF-32/R-G32-40

CIEXS-32/R-G32-40

3

7.5

10

10

30

30

50

2

CIE12-50/R-G40-40

CIEXF-50/R-G40-40

CIEXS-50/R-G40-40

3

10

15

15

40

40

50

2

CIE12-50/R-G50-80

CIEXF-50/R-G50-80

CIEXS-50/R-G50-80

5

10

20

20

50

50

50

3

CIE12-85/R-G63-80

CIEXF-85/R-G63-80

CIEXS-85/R-G63-80

5

15

20

25

60

60

50

3

CIE12-85/R-G75-80

CIEXF-85/R-G75-80

CIEXS-85/R-G75-80

* For 600V part numbers please consult factory. ++ For starters over NEMA Size 3 consult factory.

Options Part Number

Description

STR-RPL

Run pilot light (Red Standard)

STR-RST

Door mounted Reset pushbutton

STR-OFF

Off pilot light (Green Standard)

STR-STP

Emergency stop pushbutton (40mm, push-pull)

STR-1PH

Wiring for Single Phase Motor

43


INDUSTRIAL CATALOG

IPS

Industrial & Pump Starter 1Ø & 3Ø, 115~600VAC, 1–200HP Start/Stop Pushbuttons or HOA Superior Motor & Pump Protection

NEMA Sized

Internal HOA Keypad with LCD Display Door mounted pilot devices Plain English operation – easy to set up and simple to operate LEDs indicate Hand/Off/Auto modes, run and fault conditions

Built-in Pump Protection Features Standard over/undervoltage detection with selectable trip settings Optional true power measurement detects dry pump and provides alarm output; preventing dry pump operation to protect motor and pump from potential damage

Power Metering (option)

Digital display clearly delivers instantaneous & precise motor parameter data and fault conditions.

1% ANSI grade metering with pulse/analog output for accurate measurements kW and kWh data available on LCD display

Voltage & Dry Contact Inputs for PLC Compatibility Wire directly from a centralized controller to the starter, no interposing relays necessary Save on installation costs and increase reliability.

Dual Shut Down Inputs Manual shut down or automatic high-limit alarm shut down Accepts either a voltage signal or contact opening

Actuator Control Interlocks valves with starter ensuring proper sequence of operation Reduces wiring and saves on installation costs

44

www.westcoastpower.com 1-866-955-0888

The IPS includes a rugged Hand/Off/Auto switch.


PUMP CONTROLS

Wide Range Class 1-60 Electronic Overload Prevents ordering confusion and eliminates call backs due to mis-sized heaters. Advanced protective features including anti-cycling, manual/auto reset, phase sequence, phase loss, stall and locked rotor protection

Flexible Control Transformer (CPT) Multi-tap CPT input accepts all common motor voltages Integrated secondary protection – no fuses required

Our integrated CTs provide superior motor protection and metering accuracy.

Combination Versions Include Disconnect

Motor circuit protection disconnect provides branch and short circuit protection High interrupting ratings for maximum electrical system compatibility No fuses required – save time and money Lockable handle for safety Our lockable disconnect provides superior protection without costly fuses.

Options Simplex Pump Options Inputs for float control (5 float inputs maximum) Dry pump protection

Power Metering

1% ANSI Accuracy with integrated current transformers Pulse kWh output, N.O. Contact, max on resistance 8 ohms, max 45V 4- 20 mA kW output Includes kW, kWh display

Ground Fault Protection

Over/Under Voltage

Protects motors from damage due to ground current conditions UL 1053 Certified

Protects motors from damage Adjustable minimum and maximum voltage thresholds

24V Actuator Control

Time Delay

Option in lieu of 120VAC standard

Programmable On/Off delay

45


INDUSTRIAL CATALOG

Specifications Starter Type Industrial & Pump Starter Standard or Combination UL Type 4/12 Enclosure User Interface Internal Display

Digital keypad with LEDs

LED pilot lights

Hand, Off, Auto, Run, Fault

LCD parameter display

16 character, dual line, backlight

22mm Pilot Devices

HOA, Start/Stop Pushbuttons, Reset

Standard Control Operations Inputs Voltage Auto Run

Apply 10 - 130VAC/DC to energize

Emergency Power Off

Apply 10 - 130VAC/DC to energize

Actuator position switch

N.O. dry contact closure

Permissive Auto

N.O. dry contact closure

Shutdown

N.C. dry contact input

Outputs Proof of flow status relay (adjustable)

N.O., 0.3A@125VAC; 1A@24VAC

Fault relay

N.O., 0.3A@125VAC; 1A@24VAC

Actuator motor control

120VAC, 0.2A max (24VAC optional)

Power fail mode

Restart last mode, no delay (default)

Operational

Restart with delay Restart Off - LED flashes last mode On/Off Time Delay

Programmable, selectable from 0.1 to 99 seconds

Protective Functions Overload Type Current Setting Range

Mechanical Electronic; I t Thermal Trip Curve 2

Enclosure Types

UL Type 1 or UL Type 4/12

0.5 - 95A

Trip Class Class 5 - 60 Reset Phase Unbalance Phase Loss Stall/Locked Rotor* Cycle Fault*

Manual or Automatic Trip within 1 second at programmed unbalance percentage (75% default) Trip within 1 second (50% default) Trip within 0.5 seconds @ 300% FLA Trip if cycle rate exceeds 1200 starts per hour

Under Power Trip*

Trip within 10 seconds @ 50% measured horsepower

Phase Sequence*

Trip within 0.1 seconds upon reverse phase detection

Warm Start Provision

Delays motor restart if calculated motor temperature exceeds thermal curve

Ground Fault Over/Under Voltage

UL1053 Certified (Optional) Selectable trip within 0.1-99 seconds (Optional)

*Programmable On or Off. See owner’s manual for customer selectable settings.

46

www.westcoastpower.com 1-866-955-0888

Environmental Ambient Operating Temp

-5° to 140° F (-20° to 60° C)

Ambient Storage Temp

-5° to 185° F (-20° to 85° C)

Relative Humidity

5% to 95% non-condensing


PUMP CONTROLS

IPS

Options

Ordering and Sizing Information

Part Number

UL Type 4/12 for outdoor use Fully sealed: welded and gasketed for long life Rugged 16 gauge steel construction Combination version features motor circuit protector to provide branch and short circuit protection.

Description

IPS-HOA

Hand/Off/Auto Control (Door Mounted)

IPS-STSP

Start/Stop Pushbutton Control (Door Mounted)

IPS-PMP

Pump Option Card (with Dry Pump Protection)

IPS-PWR

Power Monitoring with Pulse/Analog output

IPS-DRY

Dry Pump Protection

IPS-GFLT

Ground Fault Protection

IPS-TMR

Programmable On/Off Delay Timer

IPS-24

24V Actuator Control

UL Type 4/12 Outdoor Enclosure

Standard Industrial Pump Starter - Electronic Overload Horsepower Single Phase

Three Phase

SCIC KAIC @460V

NEMA Size

Part Number

115V

230V

200V

230V

460V

575V*

1/2

2

3

5

7.5

5

00

IPS12-9/J-9 IPS12-18/J-18

1

3

5

7.5

10

15

5

0

2

5

7.5

10

20

25

5

1

IPS12-32/J-32

3

10

20

25

40

50

5

2

IPS12-50/J-50

5

15

30

40

60

75

10

3

IPS12-85/J-85

UL Type 4/12 Outdoor Enclosure

Combination Industrial Pump Starter - Electronic Overload Horsepower Single Phase

Three Phase

115V

230V

200V

1/10

1/6

1/8

1/3

3/4

1/4

1/2

1

1/3

1

1/2 1/2 1

SCIC KAIC @460V

NEMA Size

Part Number

230V

460V

575V*

3/4

3/4

65

00

IPS12-9/J-G1.6-9

1/2

1/2

1

1.5

65

00

IPS12-9/J-G2.5-9

3/4

2

3

65

00

IPS12-9/J-G4-9

1.5

3

5

65

00

IPS12-9/J-G6-9

2

2

5

5

65

0

IPS12-18/J-G8-18

1.5

2

3

5

7.5

65

0

IPS12-18/J-G10-18

2

3

3

7.5

10

65

0

IPS12-18/J-G13-18

3

3

5

10

15

30

0

IPS12-18/J-G17-18 IPS12-32/J-G22-32

1.5

3

5

7.5

15

20

30

1

2

3

7.5

7.5

15

20

30

1

IPS12-32/J-G26-32

2

5

7.5

10

20

25

30

1

IPS12-32/J-G32-32

3

7.5

10

10

30

30

50

2

IPS12-50/J-G40-50

3

10

15

15

30

40

50

2

IPS12-50/J-G50-50

5

10

20

20

40

60

50

3

IPS12-85/J-G63-85

5

15

20

25

50

60

50

3

IPS12-85/J-G75-85

* For 600V part numbers please consult factory. ++ For starters over NEMA Size 3 consult factory.

47


INDUSTRIAL CATALOG

SPS

Standard Pump Starter 1Ø & 3Ø, 115~600VAC, 1–300HP HOA Switch with LED Run Pilot Light Electronic Motor Protection

NEMA Sized

Economical and Functional Pump Starter Control Heavy Duty HOA Switch with Run Pilot Light Simple and functional basic control Long life LED pilot light

Wide Range Class 1-30 Electronic Overload Prevents ordering confusion and eliminates call backs due to mis-sized heaters Advanced protective features including phase loss, phase imbalance, stall protection & manual reset

Rugged HOA switch

Flexible Control Transformer (CPT) Multi-tap CPT input accepts all common motor voltages Integrated secondary protection – no fuses required Standard 120VAC secondary control

Specifications Starter Type Standard Pump Starter

Our lockable disconnect provides superior protection without costly fuses.

Standard or Combination UL Type 1 or UL Type 4/12 Enclosure User Interface HOA Selector switch with Run pilot light Standard Control Operations Inputs

Protective Functions Dry Auto Run

N.O. dry contact closure to energize starter

Mechanical Enclosure types

Current Setting Range 0.3 - 1.5A, 1 - 5A, 4.4 - 22A, 8 - 40A, 16 - 80A UL Type 1 or UL Type 4/12

Environmental Ambient Operating Temp -5° to 140° F (-20° to 60° C) Ambient Storage Temp -5° to 185° F (-20° to 85° C) Relative Humidity 5% to 95% non-condensing

48

Overload Type Electronic; I2t Thermal Trip Curve

www.westcoastpower.com 1-866-955-0888

Trip Class Class 1-30 Reset Manual Phase Unbalanced Trip within 3 seconds @ 70% unbalance Phase Loss Trip within 3 seconds Stall Condition Trip within 3 seconds @ 170% FLA


PUMP CONTROLS

Combination Versions Include Disconnect

Motor circuit protection disconnect provides branch and short circuit protection High interrupting ratings for maximum electrical system compatibility No fuses required – save time and money Lockable handle for safety

SPS Ordering and Sizing Information Options Part Number

Description

SPS-RST

Front Mounted Reset Pushbutton

SPS-TBC

Terminal Control Only

SPS-1PH

Wiring for Single Phase Motor

Standard Pump Starters - HOA Electronic Overload Horsepower SCIC KAIC NEMA Single Phase Three Phase Size 115V 230V 200V 230V 460V 575V* @460V

UL Type 1

UL Type 4

1/2

1

1.5

3

3

5

00

SPS1-9/J-5

SPS4-9/J-5

1

3

5

5

10

15

5

0

SPS1-18/J-22

SPS4-18/J-22

1.5

3

5

7.5

15

20

5

1

SPS1-32/J-22

SPS4-32/J-22

2

5

7.5

10

20

25

5

1

SPS1-32/J-40

SPS4-32/J-40

3

7.5

10

10

25

30

5

2

SPS1-50/J-40

SPS4-50/J-40

3

10

20

20

40

50

5

2

SPS1-50/J-80

SPS4-50/J-80

5

15

30

40

60

60

10

3

SPS1-85/J-80

SPS4-85/J-80

UL Type 1

UL Type 4

Combination Pump Starters - HOA Electronic Overload Horsepower SCIC NEMA Single Phase Three Phase KAIC Size 115V 230V 200V 230V 460V 575V* @460V 1/10

3/4

3/4

65

00

SPS1-9/J-G1.6-5

SPS4-9/J-G1.6-5

1/6

1/2

1/2

1

1.5

65

00

SPS1-9/J-G2.5-5

SPS4-9/J-G2.5-5

1/8

1/3

3/4

3/4

2

3

65

00

SPS1-9/J-G4-5

SPS4-9/J-G4-5

1/4

1/2

1

1.5

3

3

65

00

SPS1-9/J-G6-5

SPS4-9/J-G6-5

1/3

1

2

2

5

5

65

0

SPS1-18/J-G8-22

SPS4-18/J-G8-22

1/2

1.5

2

3

5

7.5

65

0

SPS1-18/J-G10-22

SPS4-18/J-G10-22

1/2

2

3

3

7.5

10

65

0

SPS1-18/J-G13-22

SPS4-18/J-G13-22

1

3

3

5

10

15

30

0

SPS1-18/J-G17-22

SPS4-18/J-G17-22

1.5

3

5

7.5

15

20

30

1

SPS1-32/J-G22-40

SPS4-32/J-G22-40

2

3

7.5

7.5

15

20

30

1

SPS1-32/J-G26-40

SPS4-32/J-G26-40

2

5

7.5

10

20

25

30

1

SPS1-32/J-G32-40

SPS4-32/J-G32-40

3

7.5

10

10

30

30

50

2

SPS1-50/J-G40-40

SPS4-50/J-G40-40

3

10

15

15

30

40

50

2

SPS1-50/J-G50-80

SPS4-50/J-G50-80

5

10

20

20

40

50

50

3

SPS1-85/J-G63-80

SPS4-85/J-G63-80

5

15

20

25

50

60

50

3

SPS1-85/J-G75-80

SPS4-85/J-G75-80

* For 600V part numbers please consult factory. ++ For starters over NEMA Size 3 consult factory.

49


INDUSTRIAL CATALOG

Duplex Alternating Pump Starter 1Ø & 3Ø, 115~600VAC, 1–200HP Start/Stop Pushbuttons or HOA UL Type 4 Enclosure

NEMA Sized

A Simple & Reliable Solution Designed for Dual Pump Control The Cerus Basic Duplex pump starter provides alternating control between two motors. A single HOA switch allows manual operation or the starter accepts a remote run command input. Each starter includes a motor selector switch to alternate between motors. Additional alternating options include an alternating relay, 24-hour timer or 7-day clock allowing maximum control flexibility.

Dependable Alternating Control

Single HOA selector switch with Run pilot lights for each pump Automatically alternates motors in the event of a fault or trip Manual alternating controlled via selector switch Optional alternating control by relay, 24-hour timer, or 7-day clock

Wide Range Class 1-30 Electronic Overload Prevents ordering confusion and eliminates call backs due to mis-sized heaters Advanced protective features including phase loss, phase imbalance, stall protection & manual reset

Combination Versions Include Disconnect

50

Motor circuit protection disconnect provides branch and short circuit protection High interrupting ratings for maximum electrical system compatibility No fuses required – save time and money Lockable handle for safety

www.westcoastpower.com 1-866-955-0888


PUMP CONTROLS

Ordering and Sizing Information Options Part Number

Description

DPX-ALT

Automatic Alternating Relay

DPX-CLK

7-Day Programmable Clock Alternation

DPX-TMR

24-Hour Timer Alternation

DPX-FLT

Fault Pilot Lights

Basic Duplex Pump Starters - HOA & Electronic Overload Horsepower SCIC NEMA KAIC Single Phase Three Phase Size 115V 230V 200V 230V 460V 575V* @460V 1

UL Type 4

UL Type 4X Fiberglass

1/2

1

1.5

3

3

5

00

DPX4-9/J-5

DPXF-9/J-5

3

5

5

10

15

5

0

DPX4-18/J-22

DPXF-18/J-22

1.5

3

5

7.5

15

20

5

1

DPX4-32/J-22

DPXF-32/J-22

2

5

7.5

10

20

25

5

1

DPX4-32/J-40

DPXF-32/J-40

3

7.5

10

10

25

30

5

2

DPX4-50/J-40

DPXF-50/J-40

3

10

20

20

40

50

5

2

DPX4-50/J-80

DPXF-50/J-80

5

15

30

40

60

60

10

3

DPX4-85/J-80

DPXF-85/J-80

Basic Combination Duplex Pump Starters - HOA & Electronic Overload Horsepower SCIC NEMA KAIC Single Phase Three Phase Size 115V 230V 200V 230V 460V 575V* @460V

UL Type 4

UL Type 4X Fiberglass

1/10

3/4

3/4

65

00

DPX4-9/J-G1.6-5

DPXF-9/J-G1.6-5

1/6

1/2

1/2

1

1.5

65

00

DPX4-9/J-G2.5-5

DPXF-9/J-G2.5-5

1/8

1/3

3/4

3/4

2

3

65

00

DPX4-9/J-G4-5

DPXF-9/J-G4-5

1/4

1/2

1

1.5

3

3

65

00

DPX4-9/J-G6-5

DPXF-9/J-G6-5

1/3

1

2

2

5

5

65

0

DPX4-18/J-G8-22

DPXF-18/J-G8-22

1/2

1.5

2

3

5

7.5

65

0

DPX4-18/J-G10-22

DPXF-18/J-G10-22

1/2

2

3

3

7.5

10

65

0

DPX4-18/J-G13-22

DPXF-18/J-G13-22

1

3

3

5

10

15

30

0

DPX4-18/J-G17-22

DPXF-18/J-G17-22

1.5

3

5

7.5

15

20

30

1

DPX4-32/J-G22-40

DPXF-32/J-G22-40

2

3

7.5

7.5

15

20

30

1

DPX4-32/J-G26-40

DPXF-32/J-G26-40

2

5

7.5

10

20

25

30

1

DPX4-32/J-G32-40

DPXF-32/J-G32-40

3

7.5

10

10

30

30

50

2

DPX4-50/J-G40-40

DPXF-50/J-G40-40

3

10

15

15

30

40

50

2

DPX4-50/J-G50-80

DPXF-50/J-G50-80

5

10

20

20

40

50

50

3

DPX4-85/J-G63-80

DPXF-85/J-G63-80

5

15

20

25

50

60

50

3

DPX4-85/J-G75-80

DPXF-85/J-G75-80

* For 600V part numbers please consult factory. ++ For starters over NEMA Size 3 consult factory.

51


INDUSTRIAL CATALOG

Advanced Duplex Pump Controller 1Ø & 3Ø, 115~600VAC, 1–200HP PLC-Based Lead/Lag & Alternating Float Switch Inputs

NEMA Sized

Engineered for the Most Demanding Pumping Applications The Advanced Duplex Pump Starter is ideal for wastewater lift stations or other redundant pump systems. Cerus designed the package specifically for float switch controlled pump stations utilizing lead-lag and alternating control. Cerus provides single or dual pump automatic operation based on demand including alternating function. In the event of a lead pump failure, Cerus increases system reliability by initiating lag pump start to ensure continued flow.

Time Saving Features & Standard Components

Integrated controls lead/lag & alternating operation Door-mounted Alarm pilot light indicates high level alarm & float switch failure (identifies specific float number) Optional circuit breaker or service entrance rated MCCB Flexible control for three, four or five float switch systems Automatic alternating control

Hand/Off/Auto switches for independent local or remote operation Dual Run pilot lights indicate motor operation Adjustable time for lag start delay and alternation settings Fault and Alarm contact outputs allow integration with external devices

Wide Range Class 1-30 Electronic Overload Prevents ordering confusion and eliminates call backs due to mis-sized heaters Advanced protective features including phase loss, phase imbalance, stall protection & manual reset

Combination Versions Include Disconnect

Motor circuit protection disconnect provides branch and short circuit protection High interrupting ratings for maximum electrical system compatibility No fuses required – save time and money Lockable handle for safety

Options

52

Elapsed-time meter for each pump Fault lights for each pump Door-mounted overload reset pushbuttons Alarm beacon light Horn or buzzer with silence pushbutton

www.westcoastpower.com 1-866-955-0888

120VAC output for external alarm light Motor seal failure relay for each pump (Motor should have a resistive float switch or probe) Motor overheat relay (motor should have an internal thermostat)


PUMP CONTROLS

Ordering and Sizing Information Options Part Number

Description

APX-FLT

Fault Pilot Lights

APX-DHM

Digital Hour Meter

APX-BCN

Alarm Beacon Light

APX-HRN

Door Mounted Horn w/ Silence Pushbutton

APX-BZR

Door Mounted Buzzer w/ Silence Pushbutton

APX-LSR

Leak Seal Relays

Advanced Duplex Pump Starters - HOA & Electronic Overload Single Phase 115V 230V

Horsepower SCIC NEMA KAIC Three Phase Size 200V 230V 460V 575V* @460V

1/2

1

UL Type 4

UL Type 4X Fiberglass

1.5

3

3

5

00

APX4-9/J-5

APXF-9/J-5

1

3

5

5

10

15

5

0

APX4-18/J-22

APXF-18/J-22

1.5

3

5

7.5

15

20

5

1

APX4-32/J-22

APXF-32/J-22

2

5

7.5

10

20

25

5

1

APX4-32/J-40

APXF-32/J-40

3

7.5

10

10

25

30

5

2

APX4-50/J-40

APXF-50/J-40

3

10

20

20

40

50

5

2

APX4-50/J-80

APXF-50/J-80

5

15

30

40

60

60

10

3

APX4-85/J-80

APXF-85/J-80

Advanced Combination Duplex Pump Starters - HOA & Electronic Overload Single Phase 115V 230V

Horsepower SCIC NEMA KAIC Three Phase Size 200V 230V 460V 575V* @460V

1/10

3/4

3/4

65

UL Type 4

UL Type 4X Fiberglass

00

APX4-9/J-G1.6-5

APXF-9/J-G1.6-5

1/6

1/2

1/2

1

1.5

65

00

APX4-9/J-G2.5-5

APXF-9/J-G2.5-5

1/8

1/3

3/4

3/4

2

3

65

00

APX4-9/J-G4-5

APXF-9/J-G4-5

1/4

1/2

1

1.5

3

3

65

00

APX4-9/J-G6-5

APXF-9/J-G6-5

1/3

1

2

2

5

5

65

0

APX4-18/J-G20-22

APXF-18/J-G20-22

1/2

1.5

2

3

5

7.5

65

0

APX4-18/J-G25-22

APXF-18/J-G25-22

1/2

2

3

3

7.5

10

65

0

APX4-18/J-G30-22

APXF-18/J-G30-22

1

3

3

5

10

15

30

0

APX4-18/J-G50-22

APXF-18/J-G50-22

1.5

3

5

7.5

15

20

30

1

APX4-32/J-G60-40

APXF-32/J-G60-40

2

5

7.5

10

20

25

30

1

APX4-32/J-G80-40

APXF-32/J-G80-40

3

7.5

10

10

30

30

50

2

APX4-50/J-G100-40

APXF-50/J-G100-40

3

10

15

15

30

40

50

2

APX4-50/J-G125-80

APXF-50/J-G125-80

5

10

20

20

40

50

50

3

APX4-85/J-G160-80

APXF-85/J-G160-80

5

15

20

25

50

60

50

3

APX4-85/J-G200-80

APXF-85/J-G200-80

* For 600V part numbers please consult factory. ++ For starters over NEMA Size 3 consult factory.

53


INDUSTRIAL CATALOG

Enclosed VFD Pump Package

1Ø & 3Ø Input, 200~230VAC & 480VAC, 1–125HP Phase Conversion Capabilities UL Type 3R Enclosure

Responsive Control for Demand Driven Pump Systems For pumping applications that require constant discharge pressure, Cerus provides a package that varies the flow rate to maintain a pressure set point. Gain increased energy savings from demand-based pump usage including Sleep Mode, which continues to monitor system set point while stopping VFD output during periods of low demand.

Designed to Withstand Harsh Pumping Environments P-Series VFD motor control with additional application-specific protective options - Lightning/Surge Arrestor - Line Reactors - Load Reactors - dV/dT Filter UL Type 3R enclosure reduces thermal absorption with white, solar reflective finish and filtered cooling fans Standard enclosed VFD package is rated for 92° F outside temperature, non-direct sunlight Attain up to 110° F outside temperature, non-direct sunlight by de-rating VFD

Functionality

54

A single VFD has the capability to control up to four additional pump starters, VFDs, or soft starters in lead-lag operation, reducing the need for additional controls Sleep mode reduces energy consumption by stopping pumps during periods of low demand Flexible sensor inputs accept 0-10VDC and 4-20mA analog signals VFD provides additional 12VDC and 24VDC power for sensors Dual PID control with Pre-PID mode and time delay reduces water hammer and cavitation while providing precise system control

www.westcoastpower.com 1-866-955-0888


PUMP CONTROLS

Ordering and Sizing Information Options Part Number

Description

VFD-RPL/120

Run Pilot Light for Type 12 & 3R (Green Standard)

VFD-FLT/120

Fault Pilot Light for Type 12 & 3R (Red Standard)

VFD-OFF/120

Off Pilot Light for Type 12 & 3R (Red Standard)

VFD-HOA

Hand-Off-Auto Switch for Enclosed Drives

VFD-SPD

Door Mounted Speed Potentiometer

VFD-LTA

Lightning Arrestor

VFD-KPD

Door Mounted Keypad

VFD-KPD/4X

Door Mounted Keypad with Type 4X Cover

UL Type 3R VFD Pump Packages (3-Phase, 200~230V) 1Ø HP*

HP

FLA

Part Number

3% Line Reactor

Output Reactor

Output Filter

2

5

24

CIE3R-PMP005-P2

VFD-KDRB22L

VFD-KDRD1P

VFD-V1K16A00

3

7.5

24

CIE3R-PMP007-P2

VFD-KDRB23L

VFD-KDRD2P

VFD-V1K25A00

5

10

32

CIE3R-PMP010-P2

VFD-KDRD25L

VFD-KDRD3P

VFD-V1K35A00

7.5

15

46

CIE3R-PMP015-P2

VFD-KDRD24L

VFD-KDRC1P

VFD-V1K45A00

10

20

60

CIE3R-PMP020-P2

VFD-KDRD26L

VFD-KDRF1P

VFD-V1K55A00

10

25

74

CIE3R-PMP025-P2

VFD-KDRC22L

VFD-KDRF2P

VFD-V1K80A00

15

30

88

CIE3R-PMP030-P2

VFD-KDRF24L

VFD-KDRF3P

VFD-V1K80A00

20

40

115

CIE3R-PMP040-P2

VFD-KDRF25L

VFD-KDRH1P

VFD-V1K110A00

* Maximum HP of 3-phase motor in single phase power applications

UL Type 3R VFD Pump Packages (3-Phase, 380~480V) 1Ø HP*

HP

FLA

Part Number

3% Line Reactor

Output Reactor

Output Filter

2

5

12

CIE3R-PMP005-P4

VFD-KDRA3L

VFD-KDRA3P

VFD-V1K8A00

3

7.5

12

CIE3R-PMP007-P4

VFD-KDRA4L

VFD-KDRA4P

VFD-V1K12A00

5

10

16

CIE3R-PMP010-P4

VFD-KDRA5L

VFD-KDRB1P

VFD-V1K18A00

7.5

15

24

CIE3R-PMP015-P4

VFD-KDRB2L

VFD-KDRD1P

VFD-V1K21A00

10

20

30

CIE3R-PMP020-P4

VFD-KDRB1L

VFD-KDRD2P

VFD-V1K27A00

10

25

39

CIE3R-PMP025-P4

VFD-KDRD1L

VFD-KDRD3P

VFD-V1K35A00

15

30

45

CIE3R-PMP030-P4

VFD-KDRD2L

VFD-KDRD4P

VFD-V1K45A00

20

40

61

CIE3R-PMP040-P4

VFD-KDRC1L

VFD-KDRC1P

VFD-V1K55A00

20

50

75

CIE3R-PMP050-P4

VFD-KDRF2L

VFD-KDRF1P

VFD-V1K80A00

20

60

91

CIE3R-PMP060-P4

VFD-KDRF4L

VFD-KDRF2P

VFD-V1K80A00

20

75

110

CIE3R-PMP075-P4

VFD-KDRF3L

VFD-KDRF3P

VFD-V1K110A00

20

100

152

CIE3R-PMP0100-P4

VFD-KDRH3L

VFD-KDRH1P

VFD-V1K130A00

20

125

183

CIE3R-PMP0125-P4

VFD-KDRH2L

VFD-KDRI1P

VFD-V1K160A00

* Maximum HP of 3-phase motor in single phase power applications

55


INDUSTRIAL CATALOG

Advanced Duplex VFD Pump Package 1Ø & 3Ø Input, 200~230VAC & 480VAC, 1–125HP Phase Conversion Capabilities UL Type 3R Enclosure

Engineered for the Most Demanding Pumping Applications The Advanced Duplex VFD Pump package is ideal for domestic water pump and booster pump systems. Cerus designed the package specifically to maintain a pressure set point based on sensor feedback using internal PID control. This package provides the most economic pump control solution by reducing both energy and maintenance costs.

Maintain System Pressure with Single Sensor Feedback

Integrated controls lead/lag & alternating operation Optional circuit breaker or service entrance rated MCCB Single pressure transducer provides feedback for both PID control loops Automatic alternating control

Options

56

Run pilot lights Fault pilot lights Off pilot lights Door-mounted potentiometer Door-mounted keypad Door-mounted keypad with Type 4X cover

www.westcoastpower.com 1-866-955-0888

Hand/Off/Auto switches for independent local or remote operation Adjustable time for lag start delay and alternation settings Fault contact output allow integration with external devices


PUMP CONTROLS

Ordering and Sizing Information Options Part Number

Description

VFD-RPL/120

Run Pilot Light for Type 12 & 3R (Green Standard)

VFD-FLT/120

Fault Pilot Light for Type 12 & 3R (Red Standard)

VFD-OFF/120

Off Pilot Light for Type 12 & 3R (Red Standard)

VFD-SPD

Door Mounted Speed Potentiometer

VFD-LTA

Lightning Arrestor

VFD-KPD

Door Mounted Keypad

VFD-KPD/4X

Door Mounted Keypad with Type 4X Cover

UL Type 3R VFD Pump Packages (3-Phase, 200~230V) 1Ø HP*

HP

FLA

Part Number

3% Line Reactor

Output Reactor

Output Filter

2

5

24

CIE3R-ADP005-P2

VFD-KDRB22L

VFD-KDRD1P

VFD-V1K16A00

3

7.5

24

CIE3R-ADP007-P2

VFD-KDRB23L

VFD-KDRD2P

VFD-V1K25A00

5

10

32

CIE3R-ADP010-P2

VFD-KDRD25L

VFD-KDRD3P

VFD-V1K35A00

7.5

15

46

CIE3R-ADP015-P2

VFD-KDRD24L

VFD-KDRC1P

VFD-V1K45A00

10

20

60

CIE3R-ADP020-P2

VFD-KDRD26L

VFD-KDRF1P

VFD-V1K55A00

10

25

74

CIE3R-ADP025-P2

VFD-KDRC22L

VFD-KDRF2P

VFD-V1K80A00

15

30

88

CIE3R-ADP030-P2

VFD-KDRF24L

VFD-KDRF3P

VFD-V1K80A00

20

40

115

CIE3R-ADP040-P2

VFD-KDRF25L

VFD-KDRH1P

VFD-V1K110A00

* Maximum HP of 3-phase motor in single phase power applications

UL Type 3R VFD Pump Packages (3-Phase, 380~480V) 1Ø HP*

HP

FLA

Part Number

3% Line Reactor

Output Reactor

Output Filter

2

5

12

CIE3R-ADP005-P4

VFD-KDRA3L

VFD-KDRA3P

VFD-V1K8A00

3

7.5

12

CIE3R-ADP007-P4

VFD-KDRA4L

VFD-KDRA4P

VFD-V1K12A00

5

10

16

CIE3R-ADP010-P4

VFD-KDRA5L

VFD-KDRB1P

VFD-V1K18A00

7.5

15

24

CIE3R-ADP015-P4

VFD-KDRB2L

VFD-KDRD1P

VFD-V1K21A00

10

20

30

CIE3R-ADP020-P4

VFD-KDRB1L

VFD-KDRD2P

VFD-V1K27A00

10

25

39

CIE3R-ADP025-P4

VFD-KDRD1L

VFD-KDRD3P

VFD-V1K35A00

15

30

45

CIE3R-ADP030-P4

VFD-KDRD2L

VFD-KDRD4P

VFD-V1K45A00

20

40

61

CIE3R-ADP040-P4

VFD-KDRC1L

VFD-KDRC1P

VFD-V1K55A00

20

50

75

CIE3R-ADP050-P4

VFD-KDRF2L

VFD-KDRF1P

VFD-V1K80A00

20

60

91

CIE3R-ADP060-P4

VFD-KDRF4L

VFD-KDRF2P

VFD-V1K80A00

20

75

110

CIE3R-ADP075-P4

VFD-KDRF3L

VFD-KDRF3P

VFD-V1K110A00

20

100

152

CIE3R-ADP0100-P4

VFD-KDRH3L

VFD-KDRH1P

VFD-V1K130A00

20

125

183

CIE3R-ADP0125-P4

VFD-KDRH2L

VFD-KDRI1P

VFD-V1K160A00

* Maximum HP of 3-phase motor in single phase power applications

57


VARIABLE FREQUENCY

DRIVES

Featuring Space Vector Modulation

Reduced harmonic distortion, torque ripple, and current ripple* Motors run cooler, smoother with greater torque and efficiency

* As compared to typical sinusoidal pulse width modulation


C Series

GS Series

Micro-Single Phase

Compact Space Vector VFD Dual Rated Optimized

Description

A fully capable micro drive that accepts single phase input and provides three phase space vector pulse width modulated output.

An economical, compact and full-featured micro drive delivers high performance control through programmable inputs, PID operation and communications.

Dual-rated for either variable or constant torque applications. Integrated communications, dual PID control and sleep mode maximize installation flexibility.

Horsepower Range

1/2~3HP

1/2~5HP

7.5~400HP

Voltage Ratings

Input

1Ø, 200~230V (+10%, -15%)

3Ø, 200~230V (+10%, -15%) 3Ø, 380~480V (+10%, -15%)

3Ø, 200~230V (+10%, -15%) 3Ø, 380~480V (+10%, -15%)

Output

200~230V

3Ø, 200~230V 3Ø, 380~480V

3Ø, 200~230V 3Ø, 380~480V

Input

50-60Hz

50-60Hz

50-60Hz

Output

0-400Hz

0-400Hz

0-120Hz

User Interface

3-Character LED Display with 4-Direction Keypad & Potentiometer

4-Character LED Display with 4-Direction Keypad

32-Character Backlit LCD Display with Keypad

Digital Inputs

5 Programmable

8 Programmable

8 Programmable

Analog Inputs

0-10VDC & 4-20mA

0-10VDC & 4-20mA

0-10VDC & 4-20mA

Analog Outputs

0-10VDC

0-10VDC

0-10VDC

Enclosure

Open Chassis (IP20)

UL Type 1 (Optional)

UL Type 1 (Standard)

Frequency Ranges

P Series


INDUSTRIAL CATALOG

Micro-Single Phase C Series VFD

0.5–3HP Input 1Ø, 230VAC - Output 3Ø, 230VAC Space Vector Pulse Width Modulation

Standard Features

S ensorless & space vector control (Space Vector PWM by IGBT) 150% torque at 0.5Hz. 1~400Hz output frequency Heavy duty: rated at 100% load at 15kHz carrier frequency

Intuitive Interface, Easy to Program

PID control for built-in process applications Built-in potentiometer Programmable I/O PNP/NPN selectable digital inputs 0~10VDC analog output (PWM) Optional ModBus communications Ground fault protection Built-in RFI filter (Class A)

The C-Series interface features a jogwheel and LED display.

Terminal connections on the C-Series drive allow for easy setup.

60

Easy user setup Improved torque at low speed Optimized motor control Auto-tuning algorithm simplifies commissioning

www.westcoastpower.com 1-866-955-0888


VARIABLE FREQUENCY DRIVES

Specifications Output Ratings Input Ratings

Operation

Input Signal

Voltage (V) Frequency (Hz) Voltage (V) Frequency (Hz) Control method Frequency setting resolution Frequency setting accuracy V/F ratio Overload capacity Torque boost Assigned terminals Programmable input terminals Analog output Operator control Frequency setting Start signal Multi-step operation Multi-step accel./decel. time Operational functions

Three phase, 200~230V 0~400Hz Single phase, 200~230V (±10%) 50~60Hz (±5%) Sensorless vector, V/F control (Space vector PWM) Digital reference: 0.01Hz (below 99Hz) & 0.1Hz (100Hz and over), Analog reference: 0.03Hz at 50Hz Digital: 0.01% of maximum output frequency, Analog: 0.1% of maximum output frequency Linear, Square, User V/F 1 minute at 150%, 30 seconds at 200% (with inverse characteristic proportional to time) Auto, Manual (0~15%) FX (forward), RX (reverse), BX (inverter stop input), RST (reset), JOG (jog) 5 digital Inputs 0~10V Linear 3 digit LED keypad, Terminals, ModBus communication Analog: 0~10V, 4~20mA, Digital: Keypad, Communication: ModBus Forward, Reverse Setting up to 8 speeds (using multi-function terminal) 0.1~6000 seconds. Maximum 8 pre-defined steps using multi-function terminals DC braking, Frequency limit, Frequency jump, Second motor function, Slip compensation, Reverse rotation prevention, Auto restart, PID controls

Emergency stop Interrupting output from inverter Jog Jog operation at 10Hz Fault reset Resets fault signal when protective function is active Operational status

Output Signal

Protective Functions

Operating Environment

Dimensions (H x W x D) Weight (lbs)

Frequency detection, Overload alarm, Stall, Overvoltage, Undervoltage, Inverter overheat, Run, Stop, Constant speed, Speed search, Fault output (relay and open collector output)

Indicator Output frequency, Output current, Output voltage, DC voltage, RPM Overvoltage, Undervoltage, Overcurrent, Inverter overheat, Motor overheat, I/O phase loss, I/O miss wiring, Trip Overload, Speed command loss, Hardware fault, Communication error Alarm Stall; Overload Ambient temperature -10°~ 40° C Storage temperature -20°~ 65° C Humidity 90% Relative Humidity maximum (non-condensing) Altitude & Vibration 1000m max, 5.9m/sec2(0.6g) max. Application site No corrosive gas, flammable gas, oil mist or dust CI-000-C2, CI-001-C2 5.63” x 3.11” x 5.63” CI-002-C2, CI-003-C2 5.63” x 6.14” x 5.63” CI-000-C2, CI-001-C2 2.9 lbs CI-002-C2, CI-003-C2 5.4 lbs

Micro-Single Phase C-Series VFD HP

kW

Capacity (kVA)

FLA

Part Number

3% Line Reactor*

1/2

0.4

0.95

2.5

CI-000-C2-1P

KDRULA54LE01

1

0.75

1.9

5

CI-001-C2-1P

KDRULA25LE01

2

1.5

3

8

CI-002-C2-1P

KDRULA27LE01

3

2.2

4.5

12

CI-003-C2-1P

KDRULA28LE01

* Line Reactors housed in separate UL Type 1 Enclosure

Option Description

Part Number

ModBus communication card

CI-MB-COM-C

61


INDUSTRIAL CATALOG

Compact GS Series VFD 0.5–5HP

200~230VAC, 380~480VAC, 3Ø Compact Design, Sensorless & VF Control

Intelligent High Performance P recise control and high starting torque (up to 150% at 0.5 Hz (Space Vector PWM by IGBT) Auto carrier frequency adjusts inversely in relation to temperature of drive for long term reliability Ground fault protection of output terminal during run Quiet operation thanks to fan control coordination with motor start/stop

Easy To Set Up and Operate

With sensorless control the GS series makes motor control easy.

ew 4-direction keypad makes parameter settings a snap N Operation algorithm helps prevent nuisance tripping Auto & manual torque boost Optimum acceleration and deceleration curves set automatically for maximum torque - or choose one of three different patterns 8 preset speeds

Flexible

62

ModBus & 485 communication for easy integration Built-in dynamic braking unit (external resistor required) Remote keypad mounting available for flexible installation options Built-in fault memory (stores last five fault conditions)

www.westcoastpower.com 1-866-955-0888

The easy to use 4-direction keypad makes settings a snap.


VARIABLE FREQUENCY DRIVES Specifications Output ratings Input ratings

Operation

Voltage (V) Frequency (Hz) Voltage (V) Frequency (Hz) Control method Frequency setting resolution Frequency setting accuracy V/F ratio Overload capacity Torque boost Assigned terminals Programmable input Analog output Operator control Frequency setting Start signal Multi-step operation

Three phase, 200~230V or Three phase, 380~480V 0~400Hz Three phase, 200~230V (+10%, -15%) or Three phase, 380~480V (+10%, -15%) 50~60Hz (±5%) Sensorless Vector, V/F control (Space vector PWM) Digital reference: 0.01Hz (below 99Hz) & 0.1Hz (100Hz and over); Analog reference: 0.03Hz at 50Hz Digital: 0.01% of maximum output frequency; Analog: 0.1% of maximum output frequency Linear; Square; User V/F 1 minute at 150%; 30 seconds at 200% (with inverse characteristic proportional to time) Auto; Manual (0~15%) FX (forward), RX (reverse), BX (inverter gate blocking), RST (reset), JOG (jog) 8 digital inputs 0~10V linear 4 digit LED display/keypad, Terminals, ModBus communication Analog: 0~10V, 4~20mA, Digital: Keypad, Communication: ModBus Forward, Reverse Setting up to 8 speeds (using multi-function terminal)

Multi-step 0.1~6000 seconds. Maximum 8 pre-defined steps using multi-function terminals accel./decel. time

Input signal

Operational functions

DC braking, Frequency limit, Frequency jump, Second motor function, Slip compensation, Reverse rotation prevention Auto restart, PID controls

Emergency stop Interrupting output from inverter Jog Jog operation Fault reset Resets fault signal when protective function is active Operational status

Output signal

Frequency detection, Overload alarm, Stall, Overvoltage, Undervoltage, Inverter overheat, Run, Stop, Constant speed, Speed search, Fault output (relay and open collector output)

Indicator Output frequency, Output current, Output voltage, DC voltage, rpm Trip

Protective functions

Alarm Ambient temperature Storage temperature Operating Humidity environment Altitude & Vibration Application site CI-000-GS2/GS4, CI-001-GS2/GS4 Dimensions CI-002-GS2/GS4 (H x W x D) CI-003-GS2/GS4, CI-005-GS2/GS4 CI-000-GS2/GS4, CI-001-GS2/GS4 Weight (lbs) CI-002-GS2/GS4 CI-003-GS2/GS4, CI-005-GS2/GS4

Overvoltage, Undervoltage, Overcurrent, Inverter overheat, Motor overheat, I/O phase loss, I/O mis-wiring, Overload, Speed command loss, Hardware fault, Communication error Stall, Overload -10°~ 50° C -20°~ 65° C 90% Relative Humidity maximum (non-condensing) 1000m max, 5.9m/sec2(0.6g) max. No corrosive gas, flammable gas, oil mist or dust 5.04” x 2.76” x 5.12” (Height is 6.90” w/ NEMA kit) 5.04” x 3.94” x 5.12” (Height is 6.90” w/ NEMA kit) 5.04” x 5.51” x 6.10” (Height is 6.90” w/ NEMA kit) 1.7 lbs 2.5 lbs 4.1 lbs

GS Series VFD (3-Phase, 200~230V) HP

kW

Capacity (kVA)

FLA

Part Number

NEMA 1 Kit

1/2

0.4

0.95

2.5

CI-000-GS2

CI-NEMA1-GS/A

3% Line Reactor* KDRULA54LE01

1

0.75

1.9

5

CI-001-GS2

CI-NEMA1-GS/A

KDRULA25LE01

2

1.5

3

8

CI-002-GS2

CI-NEMA1-GS/B

KDRULA27LE01

3

2.2

4.5

12

CI-003-GS2

CI-NEMA1-GS/C

KDRULA28LE01

5

3.7

6.1

16

CI-005-GS2

CI-NEMA1-GS/C

KDRULB22LE01

* Line Reactors housed in separate UL Type 1 Enclosure

GS Series VFD (3-Phase, 380~480V) HP

kW

Capacity (kVA)

FLA

Part Number

NEMA 1 Kit

3% Line Reactor*

1/2

0.4

0.95

1.25

CI-000-GS4

CI-NEMA1-GS/A

KDRULA6LE01

1

0.75

1.9

2.5

CI-001-GS4

CI-NEMA1-GS/A

KDRULA8LE01

2

1.5

3

4

CI-002-GS4

CI-NEMA1-GS/B

KDRULA1LE01

3

2.2

4.5

6

CI-003-GS4

CI-NEMA1-GS/C

KDRULA2LE01

5

3.7

6.1

8

CI-005-GS4

CI-NEMA1-GS/C

KDRULA3LE01

* Line Reactors housed in separate UL Type 1 Enclosure

Options Description

Part Number

Remote Keypad Mounting Kit (2 Meter Cable)

CI-RKPK-EXT2M-GS

Remote Keypad Mounting Kit (3 Meter Cable)

CI-RKPK-EXT3M-GS

Remote Keypad Mounting Kit (5 Meter Cable)

CI-RKPK-EXT5M-GS

63


INDUSTRIAL CATALOG

P-Series VFD

7.5–40HP (200~230VAC), 7.5–400HP (380~480VAC), 3Ø Dual Rated for Constant & Variable Torque Integrated PID Control

Intuitive Keypad Interface, Easy to Program

E asy-set up thanks to 32 character LCD & simplified parameters Each drive ships with easy to follow Quick Start guide Save, download & upload parameter settings to multiple drives with a single keypad DriveView software allows VFD to interface with a PC Displays parameters in plain English

Maximize Energy Savings

Space-vector control for clean sine wave output increasing efficiency and extending motor life Sleep-mode conserves energy when demand level falls below set threshold Automatic self tuning for maximum energy savings Quiet, super smooth 15kHz carrier frequency operation

The 32-character backlit LCD screen displays the drive’s operational status and parameter settings.

Versatile Features for the Most Demanding Applications

64

Sensorless vector control for variable load applications Built-in multi-motor control (for up to 4 additional motors) Dual PID controls Torque boost and stall prevention features guarantees smooth motor starts 8 programmable digital inputs, 2 analog inputs (0-10VDC, 4-20mA) Optional DC braking units ensure quick, controlled deceleration

www.westcoastpower.com 1-866-955-0888

The P-Series clearly marked terminal inputs and outputs allow for easy wiring and setup.


VARIABLE FREQUENCY DRIVES

Specifications Output ratings Input ratings

Operation

Voltage (V) Frequency (Hz) Voltage (V) Frequency (Hz) Input Power Factor Drive Efficiency Control method Frequency setting resolution Frequency setting accuracy V/F ratio Overload capacity Torque boost Multi-function input terminals Analog output

Three phase, 200~230V, Three phase, 380~480V 0~120Hz Three phase, 200~230V (-15%, +10%), Three phase, 380~480V (-15%, +10%) 50~60Hz (±5%) <.95 from no load to full load >96% V/F control, Sensorless vector control Digital reference: 0.01Hz (below 99Hz) & 0.1Hz (100Hz and over); Analog reference: 0.06Hz at 60Hz Digital: 0.01% of maximum output frequency; Analog: 0.1% of maximum output frequency Linear, Square, User V/F 1 minute at 120%, 10 seconds at 150% (with inverse characteristic proportional to time) Auto, Manual (0~15%) Total 8 inputs (programmable) 0~10V linear

LCD keypad, Terminals, ModBus-RTU communication Operator control 32-character Optional ModBus-RTU, RS485, ProfiBus-DP, DeviceNet, F-Net Frequency setting Analog: 0~10V, 4~20mA, additional port for Sub-Board (0~10V); Digital: Keypad, Communication Start signal Forward, Reverse Multi-step operation Setting up to 8 speeds (using multi-function terminal) Multi-step accel/decel time 0.1~6000 seconds. Maximum 8 pre-defined steps using multi-function terminals

Input signal

Operational DC braking, Frequency limit, Frequency jump, Second motor function, Slip compensation, Reverse rotation prevention, functions Auto start, Inverter bypass, Auto-tuning, Dual PID control Emergency stop Auto operation Jog Fault reset Output signal

Interrupting output from inverter Operates from internal sequence by setting multi-function terminal (5 way x 8 step) Jog operation Resets fault signal when protective function is active

Operational status Frequency detection, Overload alarm, Stall, Overvoltage, Undervoltage, Inverter overheat, Run, Stop, Constant speed, Speed search, Fault output (relay and open collector output), Inverter bypass, Auto-operation sequence Indicator Output frequency, Output current, Output voltage, DC voltage, Output torque (output voltage: 0~10V) Undervoltage, Overcurrent, Inverter overheat, Motor overheat, I/O phase loss, I/O miss wiring, Fuse open, Trip Overvoltage, Ground fault, External fault 1, 2, Option fault, Overload, Speed command loss, Hardware fault, Communication error

Protective functions

Operating environment

Alarm Ambient temperature Storage temperature Humidity Altitude-vibration Application site

Stall, Overload *Temperature sensor fault -10°~40° C -20°~65° C Less than 90% Relative Humidity maximum (non-condensing) Below 1,000m or 3,300ft. below 59 (=0.6g) No corrosive gas, combustible gas, oil mist or dust

Dimensions

Multi-Function Inputs

Programmable inputs for flexible system integration

Sleep Mode

Drive shuts down at low loads; CPU idles until demand increases

Flying Start

Drive matches motor speed at start-up

Dynamic Braking

Speed reductive capability

Auto Energy Savings

Self optimizing regulation to slash kWh Track energy consumption with no added cost!

Multi-Motor Control

Control up to 4 additional motors

Model

Height (w/NEMA kit)

Width

Depth

Weight

CI-007-P2, CI-007-P4

11.19” (11.19”)

5.91”

6.17”

10.8 lbs.

11.19” (11.19”)

7.88”

7.17”

13.2 lbs.

15.17” (17.88”)

9.85”

7.92”

28.7 lbs.

18.12” (23.59”)

11.98”

9.22”

44.1 lbs.

CI-050-P4

20.28” (25.28”)

11.81”

10.46”

59.5 lbs.

CI-060-P4, CI-075-P4

20.28” (25.28”)

11.81”

11.52”

64.0 lbs.

CI-100-P4, CI-125-P4

23.09” (30.22”)

14.57”

13.29”

94.8 lbs.

CI-150-P4, CI-200-P4

30.26”

20.80”

16.64”

223 lbs.

CI-250-P4

33.23”

20.80”

16.64”

252 lbs.

CI-350-P4, CI-400-P4

41.85”

27.17”

17.70”

441 lbs.

CI-010-P2, CI-010-P4 CI-015-P2, CI-015-P4 CI-020-P2, CI-020-P4 CI-025-P2, CI-025-P4 CI-030-P2, CI-030-P4 CI-040-P2, CI-040-P4

65


INDUSTRIAL CATALOG

Options Description

Part Number

Remote Keypad Mounting Kit (2 Meter Cable)

CI-RKPK-EXT2M-P/S

Remote Keypad Mounting Kit (3 Meter Cable)

CI-RKPK-EXT3M-P/S

Remote Keypad Mounting Kit (5 Meter Cable)

CI-RKPK-EXT5M-P/S

RS485 communication card

CI-R4-COM

DeviceNet communication card

CI-DN-COM

N2 communication card

CI-N2-COM

ProfiBus DP communication card

CI-PB-COM

P-Series VFD (3-Phase, 200~230V) Standard Duty (VT)

Heavy Duty (CT)

HP

kW

FLA

HP

kW

FLA

Part Number

7.5

5.5

24

5

3.7

17

CI-007-P2

KDRULB23LE01

10

7.5

32

7.5

5.5

23

CI-010-P2

KDRULD25LE01

15

11

46

10

7.5

33

CI-015-P2

KDRULD24LE01

20

15

60

15

11

44

CI-020-P2

KDRULD26LE01

25

18.5

74

20

15

54

CI-025-P2

KDRULC22LE01

30

22

88

25

18.5

68

CI-030-P2

KDRULF24LE01

40

30

115

30

22

84

CI-040-P2

KDRULF25LE01

3% Line Reactor*

P-Series VFD (3-Phase, 380~480V) Standard Duty (VT)

66

Heavy Duty (CT)

HP

kW

FLA

HP

kW

FLA

Part Number

3% Line Reactor*

7.5

5.5

12

5

3.7

8

CI-007-P4

KDRULA4LE01

10

7.5

16

7.5

5.5

11

CI-010-P4

KDRULA5LE01

15

11

24

10

7.5

17

CI-015-P4

KDRULB2LE01

20

15

30

15

11

22

CI-020-P4

KDRULB1LE01

25

18.5

39

20

15

28

CI-025-P4

KDRULD1LE01

30

22

45

25

18.5

34

CI-030-P4

KDRULD2LE01

40

30

61

30

22

44

CI-040-P4

KDRULC1LE01

50

37

75

40

30

55

CI-050-P4

KDRULF2LE01

60

45

91

50

37

66

CI-060-P4

KDRULF4LE01

75

55

110

60

45

80

CI-075-P4

KDRULF3LE01

100

75

152

75

55

111

CI-100-P4

KDRULH3LE01

125

90

183

100

75

134

CI-125-P4

KDRULH2LE01

150

110

223

125

90

183

CI-150-P4

KDRULH1LE01

200

132

264

150

110

223

CI-200-P4

KDRULG3LE01

250

160

325

200

132

264

CI-250-P4

KDRULG1LE01

350

220

432

250

160

325

CI-350-P4

KDRULJ2LE01

400

280

547

300

220

432

CI-400-P4

KDRULJ1LE01

www.westcoastpower.com 1-866-955-0888


VARIABLE FREQUENCY DRIVES

Dynamic Braking Units & Resistors 100% Braking Torque & 10% Duty Cycle Compatible with P Series VFD Enclosed IP20 ChassisUL Type 3R

Responsive Braking For Maximum Process Control

Resistors Sized to Dynamic Braking Unit’s Maximum Capacity Flexible sizing options using single or multiple units to meet braking requirements Built-in thermostat protects from overheating by tripping VFD if wired to digital input Combine resistors in series or in parallel connections to achieve requirements for custom applications

Dynamic Braking Units & Resistors (200~230VAC) Max HP

Part Number

DB Resistor Part Number

Min Ohms

kW

20

CI-DBU-20-2

DB8D50-3K20-10600AA0

8.5Ω

3.2

30

CI-DBU-30-2

DB5D8-5K0-10900AA0

5.8Ω

5.0

50

CI-DBU-40-2

DB4D5-6K5-10900AA0

4.5Ω

6.5

75

CI-DBU-50-2

DB3D0-10K0-10900AA0

3.0Ω

10.0

Dynamic Braking Units & Resistors (380~480VAC) Max HP

Part Number

DB Resistor Part Number

Min Ohms

kW

20

CI-DBU-20-4

DB34D0-3K20-10600AA0

34.0Ω

3.2

30

CI-DBU-30-4

DB23D0-5K00-10900AA0

23.0Ω

5.0

50

CI-DBU-40-4

DB17D0-6K50-10900AA0

17.0Ω

6.5

75

CI-DBU-50-4

DB11D5-10K0-10900AA0

11.5Ω

10.0

100

CI-DBU-60-4

DB8D50-13K0-11800AA0

8.5Ω

13.0

DBU & Resistor Sizing Guide Application

P-Series VFD

Dynamic Braking Unit

Multiplier (x HP)

Fans, Blowers & Pumps

1.0

Pump Jacks, Washing Machines, Presses & E-Stop Systems

1.5

Twisted Wires 30” max

POWER RUN OHT OCT

Cranes, Hoists, High-Inertia Turntables & Elevators

2.0

FOT

Resistor Twisted Wires 30” max

Thermostat Contact

M

67


ENGINEERED

SOLUTIONS

Because not every motor control application is the same, we offer engineered solutions for our starter and VFD products. Modifications include a full range of enclosure options capable of withstanding almost any environment, complex multi-motor control, or simply ensuring the controls follow a specific sequence of operations. We respond, often times with same day quotes depending on application complexity and job requirements.


BYPASSES & ENCLOSED DRIVES

Contact Cerus for More Information

Cerus P-Drive with Space Vector Control for high efficiency and enhanced motor life Fully-enclosed drive options Bypass cabinets with hinged enclosures and easy access terminal inputs Door mounted control options including HOA and VFD/Off/Bypass switches, speed potentiometer and pilot lights Two and Three contactor bypass configurations with disconnect options Panel space heaters available for ambient temperatures below 32° F


INDUSTRIAL CATALOG

Optimized Line Reactors 3 Phase, 600V Class UL & CE Marked Open Chassis & UL Type 1

Features

Optimized Line Reactors (200~230V)

Reduces input line distortion Eliminates transient and overvoltage nuisance tripping Provides maximum harmonic mitigation without adding capacitance Improve true power factor Helps to prevent VFD component damage

3%

5%

HP

Open Chassis

UL Type 1 Enclosed

Open Chassis

UL Type 1 Enclosed

1/2 3/4 1 1.5 2 3 5 7.5 10 15 20 25 30 40

KDRA54L KDRA53L KDRA25L KDRA26L KDRA27L KDRA28L KDRB22L KDRB23L KDRD25L KDRD24L KDRD26L KDRC22L KDRF24L KDRF25L

KDRULA54LE01 KDRULA53LE01 KDRULA25LE01 KDRULA26LE01 KDRULA27LE01 KDRULA28LE01 KDRULB22LE01 KDRULB23LE01 KDRULD25LE01 KDRULD24LE01 KDRULD26LE01 KDRULC22LE01 KDRULF24LE01 KDRULF25LE01

KDRA54H KDRA53H KDRA25H KDRA27H KDRA26H KDRA28H KDRB25H KDRB26H KDRD21H KDRD22H KDRC22H KDRF28H KDRF25H KDRF26H

KDRULA54HE01 KDRULA53HE01 KDRULA25HE01 KDRULA27HE01 KDRULA26HE01 KDRULA28HE01 KDRULB25HE01 KDRULB26HE01 KDRULD21HE01 KDRULD22HE01 KDRULC22HE01 KDRULF28HE01 KDRULF25HE01 KDRULF26HE01

Optimized Line Reactors (380~480V) 3%

Industrial Surge Arrestors Description

Part Number

3-Phase 200~240V

LA-302

3-Phase 440~600V

LA-603

Specifications

70

Maximum current: 100kA Maximum energy: 3000J Unlimited number of surges Response times to clamp: - 1 mA test: 5 ns - 10kA: 10 ns - 50kA: 25 ns

5%

HP

Open Chassis

UL Type 1 Enclosed

Open Chassis

UL Type 1 Enclosed

1/2 3/4 1 1.5 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 350 400

KDRA6L KDRA7L KDRA8L KDRA9L KDRA1L KDRA2L KDRA3L KDRA4L KDRA5L KDRB2L KDRB1L KDRD1L KDRD2L KDRC1L KDRF2L KDRF4L KDRF3L KDRH3L KDRH2L KDRH1L KDRG3L KDRG1L KDRG2L KDRJ2L KDRJ1L

KDRULA6LE01 KDRULA7LE01 KDRULA8LE01 KDRULA9LE01 KDRULA1LE01 KDRULA2LE01 KDRULA3LE01 KDRULA4LE01 KDRULA5LE01 KDRULB2LE01 KDRULB1LE01 KDRULD1LE01 KDRULD2LE01 KDRULC1LE01 KDRULF2LE01 KDRULF4LE01 KDRULF3LE01 KDRULH3LE01 KDRULH2LE01 KDRULH1LE01 KDRULG3LE01 KDRULG1LE01 KDRULG2LE01 KDRULJ2LE01 KDRULJ1LE01

KDRA6H KDRA7H KDRA8H KDRA9H KDRA1H KDRA2H KDRA3H KDRA4H KDRA5H KDRB2H KDRC3H KDRC1H KDRE2H KDRF4H KDRF1H KDRF2H KDRH2H KDRH1H KDRG3H KDRG1H KDRJ1H KDRL1H KDRL2H KDRL3H KDRL4H

KDRULA6HE01 KDRULA7HE01 KDRULA8HE01 KDRULA9HE01 KDRULA1HE01 KDRULA2HE01 KDRULA3HE01 KDRULA4HE01 KDRULA5HE01 KDRULB2HE01 KDRULC3HE01 KDRULC1HE01 KDRULE2HE01 KDRULF4HE01 KDRULF1HE01 KDRULF2HE01 KDRULH2HE01 KDRULH1HE01 KDRULG3HE01 KDRULG1HE01 KDRULJ1HE01 KDRULL1HE01 KDRULL2HE01 KDRULL3HE01 KDRULL4HE01

www.westcoastpower.com 1-866-955-0888


LINE REACTORS

Drive Output Reactors & Filters 3 Phase, 600V Class UL & CE Marked UL Type 1 & 3R Available

Output Reactors

dV/dT Output Filters

Protection for motor leads between 50 - 100 ft Protects VFD output by dampening peak voltage overshoot Extends motor life by reducing heat and audible noise Helps prevent VFD instantaneous overcurrent trips

Optimized Output Reactors Horsepower 240V

480V

3/4 1 2 3 5 7.5 10 15 20 25 30 40 -

2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 350 400

Protection for motor leads exceeding 125 ft Ensures smooth VFD sinusoidal output to motor Extends motor life by reducing heat, audible noise and insulation breakdown Reduces “reflective wave” effect by limiting peak voltage and rise time Helps prevent VFD instantaneous overcurrent trips

Optimized dV/dT Output Filter

Open Chassis

UL Type 1 Enclosed

KDRA1P KDRA2P KDRA3P KDRA4P KDRB1P KDRD1P KDRD2P KDRD3P KDRD4P KDRC1P KDRF1P KDRF2P KDRF3P KDRH1P KDRI1P KDRI2P KDRG1P KDRJ1P KDRJ2P KDRL1P KDRL2P

KDRULA1PE01 KDRULA2PE01 KDRULA3PE01 KDRULA4PE01 KDRULB1PE01 KDRULD1PE01 KDRULD2PE01 KDRULD3PE01 KDRULD4PE01 KDRULC1PE01 KDRULF1PE01 KDRULF2PE01 KDRULF3PE01 KDRULH1PE01 KDRULI1PE01 KDRULI2PE01 KDRULG1PE01 KDRULJ1PE01 KDRULJ2PE01 KDRULL1PE01 KDRULL2PE01

Horsepower 240V

480V

1/2 3/4 1-1.5 2 3 5 7.5 10 15 20 25-30 40 -

3/4 1-1.5 2 3 5 7.5 10 10 15 15 20 25 30 40 50 - 60 75 100 125 150 200 250 300 350 400

Open Chassis

UL Type 1 Enclosed

V1K2A00 V1K3A00 V1K4A00 V1K6A00 V1K8A00 V1K12A00 V1K16A00 V1K18A00 V1K21A00 V1K25A00 V1K27A00 V1K35A00 V1K45A00 V1K55A00 V1K80A00 V1K110A00 V1K130A00 V1K160A00 V1K200A00 V1K250A00 V1K305A00 V1K362A00 V1K420A00 V1K480A00

V1K2A01 V1K3A01 V1K4A01 V1K6A01 V1K8A01 V1K12A01 V1K16A01 V1K18A01 V1K21A01 V1K25A01 V1K27A01 V1K35A01 V1K45A01 V1K55A01 V1K80A01 V1K110A01 V1K130A01 V1K160A01 V1K200A01 V1K250A01 V1K305A01 V1K362A01 V1K420A01 V1K480A01

71


INDUSTRIAL CATALOG

Gage Pressure Sensors 0~500 PSIG Models Stainless Steel Construction 36” Wire Leads, 1/4”-18 NPT

Accurate, Reliable & Versatile Cerus pressure sensors are ideal for industrial and commercial applications where measurement and performance are critical. Additionally, these micro-machined sensors are compact in size, constructed of rugged materials designed to meet the highest standards of chemical compatibility.

Engineered for Superior Accuracy & Performance

±0.5% overall full scale at room temperature ±1% overall full scale over -40°C to 105°C for 75 PSI to 200 PSI Includes repeatability, hysteresis and linearity Custom ASIC provides signal conditioning for calibration and temperature compensation Optional electrical connectors available (Packard, Deutsch, Mini DIN, M12, Integral Harness)

Solid Construction Laser-welded stainless steel design for optimal media isolation Withstands up to three times full scale burst pressure Reverse voltage protected

Gage Pressure Sensors

72

0-5VDC Output

4-20mA Output

Pressure Range

Part Number

Part Number

0-15 PSIG

PG-15SB

PG-15SC

0-25 PSIG

PG-25SB

PG-25SC

0-50 PSIG

PG-50SB

PG-50SC

0-75 PSIG

PG-75SB

PG-75SC

0-100 PSIG

PG-100SB

PG-100SC

0-250 PSIG

PG-250SB

PG-250SC

0-300 PSIG

PG-300SB

PG-300SC

0-500 PSIG

PG-500SB

PG-500SC

www.westcoastpower.com 1-866-955-0888


PRESSURE SENSORS/ TRANSDUCERS

Differential Pressure Transducers 0~2” & 0~25” WC Models Dual Output Signals (4-20mA & 0-5/10VDC) Open Frame & NEMA 4 Enclosure Options

Intrinsic Flow Measurement Technology for High Accuracy

Intrinsic flow measurement results in optimal performance No gravity effect allows mounting in any position LCD display for easy setup and commissioning Switch-selectable pressure ranges Applications include static pressure measurement, variable air volume system control and monitoring filter status

Differential Pressure Transducers - 0”~2” WC Pressure Range 0~1"

0~2”

Enclosure Type

Part Number

Open Frame

PDP30-001

NEMA 4

PDP31-001

NEMA 4 w/ Probe

PDP32-001

Open Frame

PDP30-002

NEMA 4

PDP31-002

NEMA 4 w/ Probe

PDP32-002

Specifications 12-30VDC/24VAC, 30mA maximum (13VDC min for 10V full scale output)

Power Supply Output Type

Dual, 4-20mA & 0-5/10VDC (3-wire) 0-1” (Selectable 0.1, 0.5, 1.0) uni or bi-directional 0-2” (Selectable 0.5, 1”, 2”) uni or bi-directional

Output Scaling Calibrated Temperature Range

32° to 122°F (0-50°C)

Media compatibility Sensor Type Performance

Dry, oil-free air, N2 Digital CMOS intrinsic flow differential pressure

Position Effects Zero point Accuracy Span Accuracy Zero point repeatability Span repeatability Temp offset Temp span shift

None - position insensitive Zero drift 0.5 Pa 3% of reading 0.1 Pa 0.5% of reading None (less than resolution) < 0.5% of reading per 10°C

NEMA 4 enclosed Cerus Pressure Transducer shown with probe.

Selectable Ranges, Outputs and Stable Dry Media Operation

Zero drift technology ensures precision measurement LCD display for easy setup and commissioning Auto zero pushbutton input and auto zero control contact for system accuracy Applications include duct pressure monitoring and air-flow stations Differential Pressure Transducers - 0”~25” WC

Pressure Range 0~10" 0~25"

Enclosure Type

Part Number

NEMA 4

PDP31-010

NEMA 4 w/ Probe

PDP32-010

NEMA 4

PDP31-025

NEMA 4 w/ Probe

PDP32-025

Specifications Power Supply Output Type Output Scaling Calibrated Temperature Range Media Sensor Type Performance Accuracy (Linearity, hysteresis, temperature) Auto-zero input

12-30VDC/24VAC, 30mA maximum (13VDC min for 10V full scale output) Dual, 4-20mA & 0-5/10VDC (3-wire) 0-10” (Selectable 2.5, 5, 10"WC) 0-25” (Selectable 10, 15, 25"WC) 50° to 140°F (10-60°C) Dry, oil-free air, N2 Integrated, micro machined silicon piezoresistive

2.5% full scale Pushbutton and contact closure input provided

73


INDUSTRIAL CATALOG

Economy Soft Starters 2–75HP, 200~600VAC Integrated Bypass Electronic Motor Protection

Extend Equipment Life & Increase Savings Standard Features

Compact, space saving soft start with integrated electronic overload Standard, built-in bypass Aluminum chassis design ensures cool and efficient operation Integrated LED display and control terminals Rated for line or inside delta motor connections

Comprehensive Motor Protection Current limiting and integrated phase loss Starter over-temperature shut down with Reset pushbutton Metal Oxide Varistors (MOV) protect SCRs from damaging surges

Easy Setup & Operation

LED display modes include: On, Ramp Up/Down, Run, Overload, Phase Loss, Over-temp Simple dial adjustments for: Motor FLA, Initial Voltage, Current Limit, Ramp Up/Down Times Adjustable ramp setting ranges (Up/Down 0-30 seconds) End of Acceleration Relay (1 N.O. contact) Fault Output Relay (1 N.O. contact) Auxiliary relays

Economy Soft Starters Horsepower* Max 230V 460V 575V Amps

Part Number

Dimensions H x W x D (in)

Weight (lbs)

2

5

7.5

8

RVS-AX-8

9.5 x 4.75 x 4.25

6

5

10

15

17

RVS-AX-17

9.5 x 4.75 x 4.25

6

10

20

30

31

RVS-AX-31

9.5 x 4.75 x 4.25

6 12

20

40

50

58

RVS-AX-58

11 x 5 x 7.5

25

50

60

72

RVS-AX-72

11 x 5 x 7.5

12

30

60

75

85

RVS-AX-85

15 x 5 x 7.5

14

* Horsepower ratings are for estimation only. Verify actual full load amp requirements.

74

www.westcoastpower.com 1-866-955-0888


SOFT STARTS

Reduced Voltage Analog Soft Starters 3~600HP, 200~600VAC Built-In Motor Protection Open Chassis & Enclosed Options

Full-featured Soft Starter with Dual Operation Modes Standard Features

Compact, space saving design Integrated Class 20 electronic overload protection Reduce peak power consumption during motor starts Slower application torque reduces equipment shock Solid-state reversing option eliminates installation of additional components Dual operation modes to match application needs: - Constant Current mode for light duty or limited power supplies - Current Ramp mode for high inertia or heavy loads Soft stop option controls motor deceleration (eliminates water hammer in pumping applications)

Reduced Voltage Analog Soft Starters Horsepower* Max 230V 460V 575V Amps

Chassis

UL Type 1

UL Type 12

5

10

15

15

SS6-15-CH

SS6-15-N1

SS6-15-N12

10

25

30

30

SS6-30-CH

SS6-30-N1

SS6-30-N12

20

40

50

50

SS6-50-CH

SS6-50-N1

SS6-50-N12

30

60

75

75

SS6-80-CH

SS6-80-N1

SS6-80-N12

50

100

125

125

SS6-125-CH

SS6-125-N1

SS6-125-N12

75

150

200

200

SS6-200-CH

SS6-200-N1

SS6-200-N12

150

300

350

350

SS6-360-CH

SS6-360-N1

SS6-360-N12

200

400

500

500

SS6-500-CH

SS6-500-N1

SS6-500-N12

250

500

600

600

SS6-600-CH

SS6-600-N1

SS6-600-N12

300

600

800

800

SS6-800-CH

SS6-800-N1

SS6-800-N12

* Horsepower ratings are for estimation only. Verify actual full load amp requirements.

75


INDUSTRIAL CATALOG

Reduced Voltage Digital Soft Starters 3–1000HP, 200~600VAC Chassis, NEMA 1 & NEMA 12 Enclosure Options Available Bypass Configuration Option

Extreme Duty Rated Soft Starter For Industrial Demands Display & Control

Keypad and LCD display for easy starter setup, status and diagnostics Soft stop, up-to-speed contact, shorted SCR detection and line/load lugs standard with each unit Enclosed models include control power transformer 120VAC control inputs for: Start/Stop/Jog/Reverse/Reset/Enable Two or three wire control allow for remote operation options Dry contact relay outputs for: Fault/Bypass/Running/Reverse 18-month warranty

Operation & Features

Provides smooth current ramp output to motor eliminating surges and equipment shock Adjustable ramp setting ranges (Up/Down 0-60 seconds) Dual operation modes to match application needs: - Constant Current mode for light duty or limited power supplies - Current Ramp mode for high inertia or heavy loads Jog speeds: Forward at 14% of full speed, Reverse at 20% of full speed DC injection braking option for enhanced performance

Protective Functions

lass 10~30 adjustable electronic overload C 500% overload for 30 seconds guarantees heavy duty operation Single phase protection Instantaneous over-current trip Shorted SCR fault output

Integrated Bypass Rated For Emergency Starts

educes enclosure size and eliminates need for additional cooling R Ensures reliable operation with automatic transition to bypass contactor at full speed Eliminates downtime in critical applications

Specifications Power

3 Phase, 200-600VAC, 50/60Hz

Control*

115VAC 50Hz or 120VAC 60Hz

Digital Inputs Bypass Outputs Analog Input Analog Output Protection Environment Altitude & Vibration

120VAC, 2mA Relay contacts rated at 0.2A, 120VAC 0-10VDC 0-5VDC, 5mA max. Short circuit by fuses or circuit breaker Ambient Temp 0° - 40° C Humidity 90% RH max. (non-condensing) 1000m max, 5.9m/sec2(0.6g) max.

* Control voltage not supplied by soft start. CPT option available in bypass units.

76

www.westcoastpower.com 1-866-955-0888


SOFT STARTS

Ordering and Sizing Information Options Description

Part Number

Door Mounted Keypad (RS232/485)

SFS-DMK

Fault Pilot Light

SFS-FPL

Run Pilot Light

SFS-RPL

Reset Pushbutton

SFS-RST

Two Position Selector Switch

SFS-SSW2

Three Position Selector Switch

SFS-SSW3

Stop Pushbutton (Red)

SFS-STP

Start Pushbutton (Green)

SFS-STR

EtherNetIP Communication Card

SFS-EIP-COM

Reduced Voltage Digital Soft Starters - Standard Units Horsepower* 230V 460V 575V

Chassis

UL Type 12

UL Type 4

UL Type 4X

10

20

30

MS6-30-CH

MS6-30-N12

MS6-30-N4

MS6-30-N4X

20

40

50

MS6-50-CH

MS6-50-N12

MS6-50-N4

MS6-50-N4X

30

60

75

MS6-80-CH

MS6-80-N12

MS6-80-N4

MS6-80-N4X

50

100

125

MS6-125-CH

MS6B-125-N12

MS6B-125-N4

MS6B-125-N4X

75

150

200

MS6-200-CH

MS6B-200-N12

MS6B-200-N4

MS6B-200-N4X

100

200

250

MS6-250-CH

MS6B-250-N12

MS6B-250-N4

MS6B-250-N4X

150

350

400

MS6-420-CH

MS6B-420-N12

MS6B-420-N4

MS6B-420-N4X

200

400

500

MS6-500-CH

MS6B-500-N12

MS6B-500-N4

MS6B-500-N4X

250

500

600

MS6-600-CH

MS6B-600-N12

MS6B-600-N4

MS6B-600-N4X

350

700

800

MS6-800-CH

MS6B-800-N12

MS6B-800-N4

MS6B-800-N4X

Reduced Voltage Digital Soft Starters - Integrated Bypass Units Horsepower* 230V 460V 575V

Non-Fused Disconnect

Fused Disconnect

Circuit Breaker

UL Type 4

UL Type 4X

10

20

30

MS6B-30-N12-NFD

MS6B-30-N12-FD

MS6B-30-N12-CB

SFS-30-N4

SFS-30-N4X

20

40

50

MS6B-50-N12-NFD

MS6B-50-N12-FD

MS6B-50-N12-CB

SFS-50-N4

SFS-50-N4X

30

60

75

MS6B-80-N12-NFD

MS6B-80-N12-FD

MS6B-80-N12-CB

SFS-80-N4

SFS-80-N4X

50

100

125

MS6B-125-N12-NFD

MS6B-125-N12-FD

MS6B-125-N12-CB

SFS-125-N4

SFS-125-N4X

75

150

200

MS6B-200-N12-NFD

MS6B-200-N12-FD

MS6B-200-N12-CB

SFS-200-N4

SFS-200-N4X

100

200

250

MS6B-250-N12-NFD

MS6B-250-N12-FD

MS6B-250-N12-CB

SFS-250-N4

SFS-250-N4X

150

350

400

MS6B-420-N12-NFD

MS6B-420-N12-FD

MS6B-420-N12-CB

SFS-420-N4

SFS-420-N4X

200

400

500

MS6B-500-N12-NFD

MS6B-500-N12-FD

MS6B-500-N12-CB

SFS-500-N4

SFS-500-N4X

250

500

600

MS6B-600-N12-NFD

MS6B-600-N12-FD

MS6B-600-N12-CB

SFS-600-N4

SFS-600-N4X

350

700

800

MS6B-800-N12-NFD

MS6B-800-N12-FD

MS6B-800-N12-CB

SFS-800-N4

SFS-800-N4X

* For 900HP and above, please consult factory for pricing.

DC Injection Braking Units Horsepower 230V 460V 575V

Chassis

UL Type 1

UL Type 12

7.5

15

20

DCI-20-CH

DCI-20-N1

DCI-20-N12

15

30

40

DCI-40-CH

DCI-40-N1

DCI-40-N12

30

60

75

DCI-80-CH

DCI-80-N1

DCI-80-N12

50

100

125

DCI-125-CH

DCI-125-N1

DCI-125-N12

75

150

200

DCI-200-CH

DCI-200-N1

DCI-200-N12

125

250

300

DCI-300-CH

DCI-300-N1

DCI-300-N12

200

400

500

DCI-500-CH

DCI-500-N1

DCI-500-N12

77


INDUSTRIAL CATALOG

Pilot Devices & Accessories Fits 22mm Mounting Patterns UL Type 1, 12, 3R, 4 & 4X

Selector Switches

Legend Plates

2-Position

Type

Part Number

Description

Part Number

Stay Put

CB2-BD2

Spring Return

CB2-BDR2

Start Forward Up On Open Auto Reset Slow Auto-Hand Stop Reverse Down Off Close Hand Inch Fast Hand-Off-Auto Low High High Low Off On Up Down

CB2-PY2303 CB2-PY2305 CB2-PY2307 CB2-PY2311 CB2-PY2313 CB2-PY2315 CB2-PY2323 CB2-PY2327 CB2-PY2364 CB2-PY2304 CB2-PY2306 CB2-PY2308 CB2-PY2312 CB2-PY2314 CB2-PY2316 CB2-PY2321 CB2-PY2328 CB2-PY2387 CB2-PY2333 CB2-PY2334 CB2-PY2335 CB2-PY2336 CB2-PY2338

Emergency Stop (60mm)

CB2-PY9330

Emergency Stop (90mm)

CB2-PY8330

Stay Put

CB2-BD3

Spring Return

CB2-BDR3

Spring Return (R to C)

CB2-BD8

Spring Return (L to C)

CB2-BD7

Type

Part Number

2-Position

Stay Put (All)

CB2-BG4

3-Position

Stay Put (All)

CB2-BG0

3-Position

Key Switches

START

Non-Illuminated Pushbuttons

Flush Momentary

Projecting Momentary

Reset*

Emergency Stop (Red, 40mm)

Color

Part Number

White

CB2-BA1

Black

CB2-BA2

Green

CB2-BA3

Red

CB2-BA4

White

CB2-BL1

Black

CB2-BL2

Green

CB2-BL3

Red

CB2-BL4

Black (Mechanical)

CM2-BA2-RST

Black (Electrical)

CB2-BA2-RST

Style

Part Number

Turn Release

CB2-BS44

Key Release

CB2-BS14

Push/Pull

CB2-BT4

Assemblies for Selector Switches & Pushbuttons

*Mechanical style Reset utilizes CB2-RPX extension shaft and electrical style utilizes CB2-BZ contact block assembly. Contact Block & Collar Additional Contact Blocks (Max 6)

78

www.westcoastpower.com 1-866-955-0888

Contact

Part Number

1 NO

CB2-BZ101

1 NC

CB2-BZ102

2 NO

CB2-BZ103

2 NC

CB2-BZ104

1 NO & 1 NC

CB2-BZ105

1 NO

CB2-BE101

1 NC

CB2-BE102


ACCESSORIES

Complete Stations - Start/Stop Spring Return

Meets UL Type 1, 12, 3R, 4 & 4X Ratings Rugged Design Convenient standard knockouts for easy installation

Description

Part Number

Plastic Control Station

CC2P-215

Metal Control Station

CC2M-215

Compact Pilot Lights Color

Part Number

Green

CB2-B7-IV-73*

Red

CB2-B7-IV-74*

Amber

CB2-B7-IV-78*

* Select Desired Voltage From Table Upon Ordering

Modular LED Pilot Lights (Lens + Assembly)

Lens

Color

Part Number

Green

CB2-BVL03

Red

CB2-BVL04

Yellow

CB2-BVL05

Part Number CB2-BVL73* Assembly

CB2-BVL74* CB2-BVL75*

* Select Desired Voltage From Table Upon Ordering

Voltage Selection Chart

Miscellaneous Accessories Description Fixing Collar

Part Number

AC Voltage

24VAC

110VAC

CB2-B

DC Voltage

12VDC

24VDC

Spare/Replacement Keys

CB2-K455

Padlocking Attachment

CB2-BZ6

Projecting Pushbutton Boot (Clear)

CC-L

Flush Pushbutton Boot (Clear)

CC-S

5.125” plastic shaft (can be trimmed to any length)

240VAC

CB2-RPX

79


INDUSTRIAL CATALOG

DIN Rail Mountable Terminal Blocks 25~230A at 600VAC Accepts Wire Size 22~4/0 AWG Compatible with TS-32 & TS-35 DIN

Specifications

Increases conductivity and prevents corrosion through electrolytic copper conductors Screws and fasteners are made of high carbon steel to withstand higher torque Steel yoke for tight wire connections and anti-vibration Large contact points for reliable connections Optional pre-printed terminal block markers (standard numeric or custom marking available)

Choose between cage inserting (left) or central type (right) jumpers.

DK Series - Screw Clamp Connection Rated Surge Solid Wire (AWG) Voltage (kV)

Stranded Wire (AWG)

Wire Strip Length (in)

22~12

22~12

.39~.47

7

M3

.20 x 1.87 x 2.32

22~10

22~10

.39~.47

7

M3

.24 x 1.87 x 2.32

2.2

20~8

20~8

.31

15.6

M4

.31 x 1.87 x 2.32

2.2

20~6

20~6

.47~.55

15.6

M4

.39 x 1.87 x 2.32

70A

2.2

14~6

14~6

.59~.67

30.4

M5

.47 x 2.50 x 2.32

115A

2.2

12~2

12~2

.63~.71

50

M6

.63 x 2.50 x 2.32

Part Number

Rated Current

DK2.5

25A

2.2

DK4

35A

2.2

DK6

45A

DK10

60A

DK16 DK35

Torque Screw (lb-in)

Dimensions H x W x T (in)

DK50

150A

2.2

6~2(105A)

6~1/0

.98~1.18

50

M6

.79 x 3.02 x 2.78

DK95

230A

2.2

2~4(100A)

2~4/0

1.18~1.34

90

M8

.98 x 3.48 x 3.15

Accessories

Standard numeric terminal block marking (above). Custom marking available by special order.

80

Cross Jumper

Model

End Cover

Partition

End Bracket

2-Pole

3-Pole

DK2.5/GK2.5

DK2.5C

DKSPS-002

SS4

DS2.5-02P

DS2.5-03P

DK4/GK4

DK2.5C

DKSPS-002

SS4

DS4-02P

DS4-03P

Central Type

Cage Inserting 2-Pole

3-Pole

CSC-2.5-02P CSC-2.5-03P CSC-4-02P

CSC-4-03P

Terminal Markers* TM08W TM10W

DK6

DK2.5C

DKSPS-002

SS7

DS6-02P

DS6-03P

CSC-6-02P

CSC-6-03P

TM11W

DK10/GK10

DK2.5C

DKSPS-002

SS7

DS10-02P

DS10-03P

CSC-10-02P

CSC-10-03P

TM12W

DK16/GK16

DK16C

DKSPS-003

SS6

DS16-02P

DS16-03P

DK35

DK16C

DKSPS-003

SS6

DS35-02P

TM13W TM14W

DK50

SS6

TM14W

DK95

SS6

TM14W

* Specify numeric label range or custom values when ordering

www.westcoastpower.com 1-866-955-0888


ACCESSORIES

GK Series - Grounding Terminal Blocks Rated Rated Surge Solid Wire Part Number Current (AWG) Voltage (kV)

Stranded Wire Strip Wire (AWG) Length (in)

Torque (LB-in)

Screw

Dimensions H x W x T (in)

GK2.5

25A

2.2

26~12

26~12

.39~.55

6.9

M3

.22 x 1.83 x 2.20

GK4

35A

2.2

26~10

26~10

.47~.63

6.9

M3

.26 x 1.83 x 2.20

GK10

50A

2.2

16~8

16~8

.47~.63

15.6

M4

.41 x 1.83 x 2.20

GK16

65A

-

14~6

14~6

.55~.71

30.4

M5

.47 x 2.46 x 2.20

SK Series - Spring Clamp Connection End Cover

Part Number

Terminal Markers*

Rated Rated Surge Solid Wire Current Voltage (kV) (AWG)

Stranded Wire Strip Wire (AWG) Length (in)

Dimensions H x W x T (in)

SK4

SK4C

TM10W

20A

2.2

28~12

28~12

.39~.55

1.30 x 2.32 x .24

S4K4

S4K4C

TM10W

20A

2.2

28~12

28~12

.39~.55

1.30 x 3.39 x .24

Miniature Circuit Breakers 1~10A at 460VAC Thermal-magnetic Release 1, 2 & 3-Pole Models

High Value, Supplemental Circuit Breaking

D curve magnetic trip point (10x rated current) provides quick response short circuit protection UL 1077 listed, supplemental overcurrent protection for situations where UL 489 branch protection is already provided or unnecessary Ideal for highly inductive loads or transformers IP20 finger safe design and 35mm DIN-rain mountable

Mini Circuit Breakers - D Curve Magnetic Trip (6kA @ 400VAC) Amps

Part Number

Part Number

Part Number

1

CI-MCB-D/1P-1A

CI-MCB-D/2P-1A

CI-MCB-D/3P-1A

Aux Switch (1 NC) MCB-AUX-1NC

2

CI-MCB-D/1P-2A

CI-MCB-D/2P-2A

CI-MCB-D/3P-2A

Aux Switch (1 NO) MCB-AUX-1NO

3

CI-MCB-D/1P-3A

CI-MCB-D/2P-3A

CI-MCB-D/3P-3A

4

CI-MCB-D/1P-4A

CI-MCB-D/2P-4A

CI-MCB-D/3P-4A

6

CI-MCB-D/1P-6A

CI-MCB-D/2P-6A

10

1-Pole

CI-MCB-D/1P-10A

2-Pole

CI-MCB-D/2P-10A

CI-MCB-D/3P-6A 3-Pole

CI-MCB-D/3P-10A

81


INDUSTRIAL CATALOG

UL Listed Enclosures

Powder Coated or Stainless Steel Finish Quarter Turn Latches on Hinged Doors UL Type 1, 3R, 4, 4X & 12 Available

Standoffs provided for mounting sub-panels Continuous hinged door Black quarter turn latches operated with screwdriver Ground stud on door A NSI-61 gray urethane polyester powder coating

UL Type 1 Hinged Door Enclosures Dimensions (in)

Enclosure Part Number

Weight

H

W

D

(lbs.)

Sub-Panel Part Number

SCE-6N604LP SCE-8N604LP SCE-8N804LP SCE-8N806LP SCE-10N804LP SCE-10N806LP SCE-10N1004LP SCE-10N1006LP SCE-12N1004LP SCE-12N1006LP SCE-12N1204LP SCE-12N1206LP SCE-12N1208LP SCE-14N1204LP SCE-14N1206LP SCE-14N1208LP SCE-16N1206LP SCE-16N1208LP SCE-16N1606LP SCE-16N1608LP SCE-16N2006LP SCE-20N1606LP SCE-20N1608LP SCE-20N2006LP SCE-20N2008LP SCE-20N2010LP SCE-24N1606LP SCE-24N2006LP SCE-24N2008LP SCE-24N2010LP SCE-24N2406LP SCE-24N2408LP SCE-24N2412LP SCE-30N2406LP SCE-30N2408LP SCE-30N2412LP SCE-30N3008LP SCE-36N2406LP SCE-36N2408LP SCE-36N2412LP SCE-36N3006LP SCE-36N3008LP SCE-36N3012LP

6 8 8 8 10 10 10 10 12 12 12 12 12 14 14 14 16 16 16 16 16 20 20 20 20 20 24 24 24 24 24 24 24 30 30 30 30 36 36 36 36 36 36

6 6 8 8 8 8 10 10 10 10 12 12 12 12 12 12 12 12 16 16 20 16 16 20 20 20 16 20 20 20 24 24 24 24 24 24 30 24 24 24 30 30 30

4 4 4 6 4 6 4 6 4 6 4 6 8 4 6 8 6 8 6 8 6 6 8 6 8 10 6 6 8 10 6 8 12 6 8 12 8 6 8 12 6 8 12

2 2 2 2 4 5 4 6 5 8 7 9 12 7 10 13 11 15 16 20 19 19 25 24 31 39 27 28 31 32 40 42 49 51 57 61 60 56 62 73 68 69 83

SCE-6N6MP SCE-8N6MP SCE-8N8MP SCE-8N8MP SCE-10N8MP SCE-10N8MP SCE-10N10MP SCE-10N10MP SCE-12N10MP SCE-12N10MP SCE-12N12MP SCE-12N12MP SCE-12N12MP SCE-14N12MP SCE-14N12MP SCE-14N12MP SCE-16N12MP SCE-16N12MP SCE-16N16MP SCE-16N16MP SCE-20N16MP SCE-20N16MP SCE-20N16MP SCE-20N20MP SCE-20N20MP SCE-20N20MP SCE-24N16MP SCE-24N24MP SCE-24N20MP SCE-24N20MP SCE-24N24MP SCE-24N24MP SCE-24N24MP SCE-30N24MP SCE-30N24MP SCE-30N24MP SCE-30N30MP SCE-36N24MP SCE-36N24MP SCE-36N24MP SCE-36N30MP SCE-36N30MP SCE-36N30MP

Dimensions (in) Weight (lbs.) H W 4 6 6 6 8 8 8 8 10 10 10 10 10 12 12 12 14 14 14 14 18 18 18 18 18 18 22 22 22 22 22 22 22 28 28 28 28 34 34 34 34 34 34

4 4 6 6 6 6 8 8 8 8 10 10 10 10 10 10 10 10 14 14 14 14 14 18 18 18 14 18 18 18 22 22 22 22 22 22 28 22 22 22 28 28 28

*Mounting holes are located 0.75” in from each side and 0.455” from the top and bottom

82

www.westcoastpower.com 1-866-955-0888

1 1 1 1 2 2 3 3 3 3 4 4 4 4 4 4 4 4 4 4 7 7 7 9 9 9 7 11 11 11 11 11 11 13 13 13 20 21 21 21 23 23 23


ENCLOSURES Seams continuously welded and ground smooth Standoffs provided for mounting optional panels Removable stainless steel hinge pins Black quarter turn latches - opens with a screwdriver Ground stud on door and body

Standard mounting hole pattern (1.28” from sides, 0.35” from top/bottom) UL Type 4 enclosures finished with ANSI-61 gray urethane polyester powder coating over .063” carbon steel UL Type 4X enclosures finished with #4 brushed .075” Type 304 stainless steel

UL Type 4/12 & 4X Junction Enclosure Dimensions (in)

Carbon Steel Part Number

Stainless Steel Part Number

Weight

H

W

D

(lbs.)

SCE-604ELJ SCE-606ELJ SCE-806ELJ SCE-8066ELJ SCE-1008ELJ SCE-10086ELJ SCE-1210ELJ SCE-12108ELJ SCE-1212ELJ SCE-1412ELJ SCE-14128ELJ SCE-1614ELJ SCE-16148ELJ SCE-20166ELJ SCE-20168ELJ SCE-20206ELJ SCE-20208ELJ SCE-202010ELJ

SCE-604ELJSS SCE-606ELJSS SCE-806ELJSS SCE-8066ELJSS SCE-1008ELJSS SCE-10086ELJSS SCE-1210ELJSS SCE-12108ELJSS SCE-1212ELJSS SCE-1412ELJSS SCE-14128ELJSS SCE-1614ELJSS SCE-16148ELJSS — — — — —

6 6 8 8 10 10 12 12 12 14 14 16 16 20 20 20 20 20

4 6 6 6 8 8 10 10 12 12 12 14 14 16 16 20 20 20

4 4 4 6 4 6 4 8 6 6 8 6 8 6 8 6 8 10

3 4 4 5 6 8 10 12 11 13 15 16 18 21 23 25 28 31

Sub-Panel Part Number

Dimensions H

W

(lbs.)

SCE-6P4J SCE-6P4J SCE-8P6J SCE-8P6J SCE-10P8J SCE-10P8J SCE-12P10J SCE-12P10J SCE-12P12J SCE-14P12J SCE-14P12J SCE-16P14J SCE-16P14J SCE-20P16J SCE-20P16J SCE-20P20J SCE-20P20J SCE-20P20J

5.25 5.25 7.25 7.25 9.25 9.25 11.25 11.25 11.25 13.25 13.25 15.25 15.25 19.25 19.25 19.25 19.25 19.25

3.25 5.25 5.25 5.25 7.25 7.25 9.25 9.25 11.25 11.25 11.25 13.25 13.25 15.25 15.25 19.25 19.25 19.25

1 1 1 1 2 2 2 2 3 3 3 4 4 5 5 7 7 7

Weight

UL Type 3R Hinged Door Enclosure Dimensions (in)

Enclosure Part Number

H

W

D

SCE-12R1206LP SCE-12R1208LP SCE-16R1206LP SCE-16R1208LP SCE-20R1606LP SCE-20R1608LP SCE-24R2006LP SCE-24R2008LP SCE-24R2012LP SCE-30R2408LP SCE-30R2412LP SCE-36R2408LP SCE-36R2412LP SCE-36R3008LP SCE-36R3012LP SCE-42R3012LP

12 12 16 16 20 20 24 24 24 30 30 36 36 36 36 42

12 12 12 12 16 16 20 20 20 24 24 24 24 30 30 30

6 8 6 8 6 8 6 8 12 8 12 8 12 8 12 12

Weight Sub-Panel (lbs.) Part Number 12 14 16 19 20 25 28 32 35 60 64 62 73 70 85 114

Integrated rain hood ANSI-61 gray urethane polyester powder coating over galvanized steel Hinged door includes gasket

SCE-12DLP12 SCE-12DLP12 SCE-16P12 SCE-16P12 SCE-20P16 SCE-20P16 SCE-24P20 SCE-24P20 SCE-24P20 SCE-30P24 SCE-30P24 SCE-36P24 SCE-36P24 SCE-36P30 SCE-36P30 SCE-42P30

Dimensions

Weight

H

W

(lbs.)

9 9 13 13 17 17 21 21 21 27 27 33 33 33 33 39

9 9 9 9 13 13 17 17 17 21 21 21 21 27 27 27

3 3 4 4 7 7 11 11 11 16 16 22 22 27 27 33

Spot welded construction Black quarter-turn latch with padlocking provision Ground studs on door and body Standoffs provided for mounting optional sub-panels 83


INDUSTRIAL CATALOG

UL Type 4/12 & 4X Single Door Enclosures Powder Coated or Stainless Steel Finish Dust & Oil Resistant Gasket Quarter Turn Latches on Hinged Door

Construction & Specifications

Flange collar around all sides of door opening Removable print pocket Standoffs provided for mounting sub-panels Removable and interchangeable doors Black quarter turn latches operated with screwdriver Ground stud on door and body

Standard mounting holes located 0.75” from edges UL Type 4 enclosures finished with ANSI-61 gray urethane polyester powder coating over .075” carbon steel UL Type 4X enclosures finished with #4 brushed .075” Type 304 stainless steel Optional locking door latches available Additional accessories available

UL Type 4/12 & 4X Enclosures Carbon Steel Part Number SCE-12EL1206LP SCE-12EL2406LP SCE-16EL1206LP SCE-16EL1208LP SCE-16EL1408LP SCE-16EL1606LP SCE-16EL1608LP SCE-16EL2006LP SCE-16EL2008LP SCE-20EL1206LP SCE-20EL1606LP SCE-20EL1608LP — SCE-20EL1612LP SCE-20EL2006LP SCE-20EL2008LP — SCE-20EL2012LP SCE-20EL2408LP SCE-24EL1206LP SCE-24EL1606LP SCE-24EL1608LP SCE-24EL2006LP SCE-24EL2008LP SCE-24EL2010LP SCE-24EL2012LP SCE-24EL2016LP SCE-24EL2406LP SCE-24EL2408LP SCE-24EL2410LP SCE-24EL2412LP

84

Weight (lbs.)

14 28 17 21 20 21 26 27 27 22 24 27 ­— 41 29 31 — 37 35 24 31 30 42 35 37 52 61 46 43 54 51

Stainless Steel Part Number SCE-12EL1206SSLP SCE-12EL2406SSLP SCE-16EL1206SSLP SCE-16EL1208SSLP — SCE-16EL1606SSLP SCE-16EL1608SSLP — SCE-16EL2008SSLP — SCE-20EL1606SSLP SCE-20EL1608SSLP SCE-20EL1610SSLP — SCE-20EL2006SSLP SCE-20EL2008SSLP SCE-20EL2010SSLP — SCE-20EL2408SSLP — — SCE-24EL1608SSLP SCE-24EL2006SSLP SCE-24EL2008SSLP SCE-24EL2010SSLP SCE-24EL2012SSLP — — SCE-24EL2408SSLP SCE-24EL2410SSLP SCE-24EL2412SSLP

www.westcoastpower.com 1-866-955-0888

Dimensions

Weight (lbs.)

H

W

D

15 24 17 26 — 21 26 — 29 — 29 27 30 — 32 33 42 — 42 — — 32 42 37 48 52 — — 47 54 57

12 12 16 16 16 16 16 16 16 20 20 20 20 20 20 20 20 20 20 24 24 24 24 24 24 24 24 24 24 24 24

12 24 12 12 14 16 16 20 20 12 16 16 16 16 20 20 20 20 24 12 16 16 20 20 20 20 20 24 24 24 24

6 6 6 8 8 6 8 6 8 6 6 8 10 12 6 8 10 12 8 6 6 8 6 8 10 12 16 6 8 10 12

Sub-Panel Part Number SCE-12DLP12 SCE-12P24 SCE-16P12 SCE-16P12 SCE-16DLP14 SCE-16P16 SCE-16P16 SCE-20P16 SCE-20P16 SCE-20P12 SCE-20P16 SCE-20P16 SCE-20P16 SCE-20P16 SCE-20P20 SCE-20P20 SCE-24P20 SCE-20P20 SCE-24P20 SCE-12P24 SCE-24P16 SCE-24P16 SCE-24P20 SCE-24P20 SCE-24P20 SCE-24P20 SCE-24P20 SCE-24P24 SCE-24P24 SCE-24P24 SCE-24P24

Dimensions

Weight

H

W

(lbs.)

9 9 13 13 13 13 13 17 17 17 17 17 17 17 17 17 21 17 21 9 21 21 21 21 21 21 21 21 21 21 21

9 21 9 9 11 13 13 13 13 9 13 13 13 13 17 17 17 17 17 21 13 13 17 17 17 17 17 21 21 21 21

3 5 4 4 4 5 5 7 7 5 7 7 7 7 10 10 11 10 11 5 9 9 11 11 11 11 11 14 14 14 14


ENCLOSURES

Carbon Steel Part Number SCE-24EL2416LP SCE-24EL3008LP SCE-24EL3010LP SCE-30EL1606LP SCE-30EL2008LP SCE-30EL2010LP SCE-30EL2408LP SCE-30EL2410LP SCE-30EL2412LP SCE-30EL2416LP SCE-30EL2420LP SCE-30EL2424LP SCE-30EL3008LP SCE-30EL3010LP SCE-30EL3012LP SCE-30EL3608LP SCE-36EL2408LP SCE-36EL2410LP SCE-36EL2412LP SCE-36EL2416LP SCE-36EL3008LP SCE-36EL3010LP SCE-36EL3012LP SCE-36EL3016LP SCE-36EL3020LP SCE-36EL3608LP SCE-36EL3612LP SCE-36EL3616LP SCE-40EL2412LP SCE-42EL2410LP SCE-42EL3008LP SCE-42EL3010LP SCE-42EL3012LP SCE-42EL3016LP SCE-42EL3608LP SCE-42EL3610LP SCE-42EL3612LP SCE-42EL3616LP SCE-48EL2408LP SCE-48EL2412LP SCE-48EL3010LP SCE-48EL3016LP SCE-48EL3608LP SCE-48EL3610LP SCE-48EL3612LP SCE-48EL3616LP SCE-48EL3620LP SCE-60EL2412LP SCE-60EL3610LP SCE-60EL3612LP SCE-60EL3616LP SCE-60EL3620LP SCE-72EL3012LP SCE-72EL3016LP SCE-72EL3024LP SCE-72EL3612LP SCE-72EL3616LP

Weight (lbs.)

71 53 63 42 47 50 55 68 63 80 91 99 63 82 82 84 64 74 77 82 73 89 87 114 123 102 111 122 89 79 101 105 111 117 117 127 123 149 83 99 117 151 129 137 133 149 173 141 164 162 195 209 217 236 242 222 234

Stainless Steel Part Number SCE-24EL2416SSLP SCE-24EL3008SSLP SCE-24EL3010SSLP SCE-30EL1606SSLP SCE-30EL2008SSLP SCE-30EL2010SSLP SCE-30EL2408SSLP SCE-30EL2410SSLP SCE-30EL2412SSLP SCE-30EL2416SSLP — — SCE-30EL3008SSLP SCE-30EL3010SSLP SCE-30EL3012SSLP SCE-30EL3608SSLP SCE-36EL2408SSLP SCE-36EL2410SSLP — — SCE-36EL3008SSLP SCE-36EL3010SSLP SCE-36EL3012SSLP — — SCE-36EL3608SSLP SCE-36EL3612SSLP — — SCE-42EL2410SSLP — SCE-42EL3010SSLP — — — — SCE-42EL3612SSLP SCE-42EL3616SSLP — — — — — — SCE-48EL3612SSLP SCE-48EL3616SSLP — — — SCE-60EL3612SSLP SCE-60EL3616SSLP — — SCE-72EL3016SSLP — SCE-72EL3612SSLP SCE-72EL3616SSLP

Dimensions

Weight (lbs.)

H

W

D

Sub-Panel Part Number

72 58 64 42 52 57 53 68 69 80 — — 67 81 89 84 66 74 — — 75 89 94 — — 102 111 — — 84 — 105 — — — — 124 149 — — — — — — 131 153 — — — 162 195 — — 236 — 222 234

24 24 24 30 30 30 30 3 30 30 30 30 30 30 30 30 36 36 36 36 36 36 36 36 36 36 36 36 40 42 42 42 42 42 42 42 42 42 48 48 48 48 48 48 48 48 48 60 60 60 60 60 72 72 72 72 72

24 30 30 16 20 20 24 24 24 24 24 24 30 30 30 36 24 24 24 24 30 30 30 30 30 36 36 36 24 24 30 30 30 30 36 36 36 36 24 24 30 30 36 36 36 36 36 24 36 36 36 36 30 30 30 36 36

16 8 10 6 8 10 8 10 12 16 20 24 8 10 12 8 8 10 12 16 8 10 12 16 20 8 12 16 12 10 8 10 12 16 8 10 12 16 8 12 10 16 8 12 10 16 20 12 10 12 16 20 12 16 24 12 16

SCE-24P24 SCE-30P24 SCE-30P24 SCE-30P16 SCE-30P20 SCE-30P20 SCE-30P24 SCE-30P24 SCE-30P24 SCE-30P24 SCE-30P24 SCE-30P24 SCE-30P30 SCE-30P30 SCE-30P30 SCE-36P30 SCE-36P24 SCE-36P24 SCE-36P24 SCE-36P24 SCE-36P30 SCE-36P30 SCE-36P30 SCE-36P30 SCE-36P30 SCE-36P36 SCE-36P36 SCE-36P36 SCE-40P24 SCE-42P24 SCE-42P30 SCE-42P30 SCE-42P30 SCE-42P30 SCE-42P36 SCE-42P36 SCE-42P36 SCE-42P36 SCE-48P24 SCE-48P24 SCE-48P30 SCE-48P30 SCE-48P36 SCE-48P36 SCE-48P36 SCE-48P36 SCE-48P36 SCE-60P24 SCE-60P36 SCE-60P36 SCE-60P36 SCE-60P36 SCE-72P30 SCE-72P30 SCE-72P30 SCE-72P36 SCE-72P36

Dimensions

Weight

H

W

(lbs.)

21 27 27 27 27 27 27 27 27 27 27 27 27 27 27 33 33 33 33 33 33 33 33 33 33 33 33 33 37 39 39 39 39 39 39 39 39 39 45 45 45 45 45 45 45 45 45 57 57 57 57 57 69 69 69 69 69

21 21 21 13 17 17 21 21 21 21 21 21 27 27 27 27 21 21 21 21 27 27 27 27 27 33 33 33 21 21 27 27 27 27 33 33 33 33 21 21 27 27 33 33 33 33 33 21 33 33 33 33 27 27 27 33 33

14 16 16 12 16 16 16 16 16 16 16 16 24 24 24 27 22 22 22 22 27 27 27 27 27 35 35 35 40 33 33 33 33 33 39 39 39 39 31 31 39 39 46 46 46 46 46 50 58 58 58 58 71 71 71 74 74

*Mounting holes are located .75” in from each side, top and bottom.

85


INDUSTRIAL CATALOG

UL Type 4X Fiberglass Enclosures Reinforced Polyester Construction Gasketed & Sealed for Outdoor Use Hinged Screw Cover

Solid Construction for Rugged Applications

esigned for high temperature or corrosive environments D Protects components from dirt, dust, oil and water Compression molded fiberglass reinforced polyester is UV stabilized for outdoor use Stainless steel hardware Hinged door seals with neoprene gasket Standard mounting flanges keep installation hardware outside of sealed enclosure

Standards

86

L 508 and UL 50 listed (Type 1, 2, 3, 3R, 4, 4X, 12, 13) U CSA Certified Light gray color (RAL 7035) Flammability rating meets UL 508 Joint Industrial Council (JIC) enclosure sizing

Dimensions (in)

Enclosure Part Number

H

W

D

AMU664HF AMU864HF AMU1084HF AMU1206HF AMU1426HF AMU1648HF AMU1860HF AMU2060HF

6.05 8.05 10.05 12.05 14.05 16.05 18.05 20.05

6.27 6.27 8.27 10.27 12.27 14.27 16.27 16.27

4.13 4.13 4.13 6.13 6.13 8.13 10.13 10.13

www.westcoastpower.com 1-866-955-0888

Sub-Panel Part Number P66 P86 P108 P1210 P1412 P1614 P1816 P2016

Additional options and configurations available through special order. Enclosure shown above with clear poly-carbonate window.

Panel Dimensions (in) H

W

4.81 6.75 8.75 10.75 12.75 14.75 16.88 18.44

4.81 4.88 6.88 8.88 10.88 12.88 14.88 14.44


REFERENCE

Enclosure Standards NEMA and UL are standard writing organizations that are commonly recognized in North America. Their ratings are based on similar application descriptions and expected performance. UL requires enclosure testing by a qualified evaluator. Site inspectors check manufacturing practices to ensure adherence to methods and materials utilized. NEMA standards do not require independent testing and allows manufacturers to enforce their own compliance measures.

Enclosure Rating

NEMA Specification

UL Specification

Type 1

Enclosures are intended for indoor use primarily to provide a degree of protection against contact with the enclosed equipment or locations where unusual service conditions do not exist.

Indoor use primarily to provide protection against contact with the enclosed equipment and against a limited amount of falling dirt.

Type 3R

Enclosures are intended for outdoor use primarily to provide a degree of protection against falling rain and sleet; undamaged by the formation of ice on the enclosure.

Outdoor use to provide a degree of protection against falling rain; undamaged by the formation of ice on the enclosure.

Enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against windblown dust and rain, splashing water; and hose directed water; undamaged by the formation of ice on the enclosure.

Either indoor or outdoor use to provide a degree of protection against falling rain, splashing water, and hose-directed water; undamaged by the formation of ice on the enclosure.

Enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against corrosion, windblown dust and rain, splashing water, and hose-directed water; undamaged by the formation of ice on the enclosure.

Either indoor or outdoor use to provide a degree of protection against falling rain, splashing water, and hosedirected water; undamaged by the formation of ice on the enclosure; resists corrosion.

Enclosures are intended for indoor use primarily to provide a degree of protection against dust, falling dirt, and dripping noncorrosive liquids.

Indoor use to provide a degree of protection against dust, dirt, fiber flyings, dripping water, and external condensation of noncorrosive liquids.

This material is reproduced with permission from NEMA. The preceding descriptions, however are not intended to be complete representations of the National Electrical Manufacturers Association standards for enclosures.

This material is reproduced with permission from Underwriters Laboratories, Inc. Enclosures for Electrical Equipment, UL 50, Copyright 1995 and Industrial Control Equipment, UL 508, Copyright 1996 by Underwriters Laboratories Inc.

Type 4

Type 4X

Type 12

Underwriters Laboratories Inc. (UL) shall not be responsible for the use of or reliance upon a UL Standard by anyone. UL shall not incur any obligation or liability for damages, including consequential damages, arising out of or connection with the use, interpretation of, or reliance upon a UL Standard.

87


INDUSTRIAL CATALOG

UL Sizing Chart (1 Phase) HP

Volts

1/10 1/8 1/6 1/4 1/3 1/2 3/4 1 1 1/2 2 3 5 7 1/2 10 15

120 230 120 230 120 230 120 230 120 230 120 230 120 230 120 230 120 230 120 230 120 230 120 230 120 230 120 230 120 230

Cerus Motor Overload

Bend Motor Wire Size Radius* Amps (AWG) (Inches)

Contactor

3.0 1.5 3.8 1.9 4.4 2.2 5.8 2.9 7.2 3.6 9.8 4.9 13.8 6.9 16.0 8.0 20.0 10.0 24.0 12.0 34.0 17.0 56.0 28.0 80.0 40.0 100.0 50.0 135.0 68.0

MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-12 MRC-9 MRC-18 MRC-9 MRC-18 MRC-9 MRC-25 MRC-12 MRC-25 MRC-18 MRC-40 MRC-18 MRC-63 MRC-32 MRC-85 MRC-40 CRC-100 MRC-63 CRC-150 CRC-75

12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 10 12 8 12 6 10 4 8 3 8 1/0 4

1.5 2 3 1.5 3 1.5 5 2

Thermal MTK-32/3-4 MTK-32/3-1.6 MTK-32/3-4 MTK-32/3-2.5 MTK-32/3-6 MTK-32/3-2.5 MTK-32/3-8 MTK-32/3-4 MTK-32/3-8 MTK-32/3-4 MTK-32/3-13 MTK-32/3-6 MTK-32/3-18 MTK-32/3-8 MTK-32/3-18 MTK-32/3-9 MTK-32/3-25 MTK-32/3-13 MTK-32/3-25 MTK-32/3-13 MTK-63/3-40 MTK-32/3-22 MTK-63/3-65 MTK-32/3-32 MTK-95/3-85 MTK-63/3-50 CTK-100/3-125A MTK-63/3-65 CTK-150/3-150 CTK-85/3-75

Electronic

Manual Motor Starter

Motor Circuit Protector

CRP22-3P 5A CRP22-3P 5A CRP22-3P 5A CRP22-3P 5A CRP22-3P 5A CRP22-3P 5A CRP22-3S 22A CRP22-3P 5A CRP22-3S 22A CRP22-3P 5A CRP22-3S 22A CRP22-3S 22A CRP22-3S 22A CRP22-3S 22A CRP22-3S 22A CRP22-3S 22A CRP22-3S 22A CRP22-3S 22A CRP40-3S 40A CRP22-3S 22A CRP40-3S 40A CRP22-3S 22A CRP80-3S 80A CRP40-3S 40A CRP80-3S 80A CRP80-3S 80A CRP80-3S-80A

CMS-32HI-4 CMS-32HI-1.6 CMS-32HI-4 CMS-32HI-2.5 CMS-32HI-6 CMS-32HI-2.5 CMS-32HI-8 CMS-32HI-4 CMS-32HI-8 CMS-32HI-4 CMS-32HI-13 CMS-32HI-6 CMS-32HI-17 CMS-32HI-8 CMS-32HI-17 CMS-32HI-10 CMS-32HI-22 CMS-32HI-13 CMS-32HI-26 CMS-32HI-13 CMS-63HI-40 CMS-32HI-22 CMS-63HI-63 CMS-32HI-32 CMS-100HI-90 CMS-63HI-50 CMS-63HI-63 CMS-100H-75

CMS-32HI-4 CMS-32HI-1.6 CMS-32HI-4 CMS-32HI-2.5 CMS-32HI-6 CMS-32HI-2.5 CMS-32HI-6 CMS-32HI-4 CMS-32HI-8 CMS-32HI-4 CMS-32HI-10 CMS-32HI-6 CMS-32HI-17 CMS-32HI-8 CMS-32HI-17 CMS-32HI-8 CMS-32HI-22 CMS-32HI-10 CMS-32HI-26 CMS-32HI-13 CMS-63HI-40 CMS-32HI-17 CMS-63HI-63 CMS-32HI-32 CMS-100HI-90 CMS-63HI-40 CMS-100HI-100 CMS-63HI-50 CMS-100HI-75

Motor Engineering Formulas Legend E = Volts I = Amps W = Watts PF = Power Factor Eff = Efficiency HP = Horsepower 1HP = 746 Watts

AC/DC Formulas Single Phase

Three Phase

Amps when HP is known

To Find

HP x 746 E x Eff

HP x 746 E x Eff x PF

HP x 746 1.73 x E x Eff x PF

Amps when kW is known

kW x 1000 E

kW x 1000 E x PF

kW x 1000 1.73 x E x PF

Amps when kVA is known

-

kVA x 1000 E

kVA x 1000 1.73 x E

Ex I

IxE 1000

I x E x PF 1000

I x E x 1.73 x PF 1000

P R

-

IxE 1000

I x E x 1.73 1000

I x E x Eff 746

I x E x Eff x PF 746

I x E x Eff x 1.73 x PF 746

Kilowatts Kilovolt (Amps) Horsepower (Output)

AC Efficiency & Power Factor Formulas To Find Efficiency Power Factor

88

Single Phase

Three Phase

746 x HP E x I x PF

746 x HP E x I x PF x 1.732

Input Watts VxA

Input Watts E x I x PF x 1.732

www.westcoastpower.com 1-866-955-0888

Ohm’s Law E2 I2 x R R

P E

IxR

P I

P E I R E R

P I2

PxR

E2 P

E I

Motor Application Formulas Horsepower = Torque (lb-ft) x RPM 5252 Torque (lb-ft) = Horsepower x 5252 RPM


REFERENCE

UL Sizing Chart (3 Phase) HP

1/2

3/4

1

1 1/2

2

3

5

7 1/2

10

15

20

25

30

40

50

60

75

100

125

150

Volts 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480

Bend Motor Wire Size Radius Amps (AWG) (Inches) 2.4 2.2 1.1 3.5 3.2 1.6 4.6 4.2 2.1 6.6 6.0 3.0 7.5 6.8 3.4 10.5 9.6 4.8 16.7 15.2 7.6 24.0 22.0 11.0 31.0 28.0 14.0 46.0 42.0 21.0 59.0 54.0 27.0 75.0 68.0 34.0 88.0 80.0 40.0 114.4 104.0 52.0 143.0 130.0 65.0 169.4 154.0 77.0 211.2 192.0 96.0 272.8 248.0 124.0 343.2 312.0 156.0 396.0 360.0 180.0

12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 10 10 12 8 10 12 8 8 10 6 6 10 4 4 8 3 4 8 2 2 6 1/0 1 6 2/0 2/0 4 4/0 3/0 3 2 x 1/0 2 x 1/0 1 2 x 2/0 2 x 2/0 2/0 2 x 3/0 2 x 3/0 3/0

1.5 1.5 1.5 1.5 2 2 2 2 1.5 2.5 2 1.5 5 3 1.5 7 6 2 7 7 2 10 8 3 12 12 6 14 14 7 8* 7* 7

Cerus Motor Overload Contactor MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-12 MRC-12 MRC-9 MRC-18 MRC-18 MRC-9 MRC-25 MRC-25 MRC-12 MRC-35 MRC-32 MRC-18 MRC-50 MRC-50 MRC-25 MRC-63 MRC-63 MRC-32 MRC-75 MRC-75 MRC-35 MRC-95 MRC-85 MRC-50 CRC-125 CRC-125 MRC-63 CRC-180 CRC-150 MRC-75 CRC-180 CRC-180 MRC-85 CRC-300 CRC-220 CRC-125 CRC-300 CRC-300 CRC-150 CRC-400 CRC-400 CRC-180 CRC-600 CRC-400 CRC-220

Thermal MTK-32/3-2.5 MTK-32/3-2.5 MTK-32/3-1.6 MTK-32/3-4 MTK-32/3-4 MTK-32/3-1.6 MTK-32/3-6 MTK-32/3-6 MTK-32/3-2.5 MTK-32/3-8 MTK-32/3-8 MTK-32/3-4 MTK-32/3-9 MTK-32/3-9 MTK-32/3-4 MTK-32/3-13 MTK-32/3-13 MTK-32/3-6 MTK-32/3-18 MTK-32/3-18 MTK-32/3-9 MTK-32/3-25 MTK-32/3-25 MTK-32/3-13 MTK-63/3-36 MTK-32/3-32 MTK-32/3-18 MTK-63/3-50 MTK-63/3-50 MTK-32/3-25 MTK-63/3-65 MTK-63/3-65 MTK-32/3-32 MTK-95/3-85 MTK-95/3-75 MTK-63/3-40 MTK-95/3-95 MTK-95/3-85 MTK-63/3-50 CTK-100/3-125A CTK-100/3-125A MTK-63/3-65 CTK-220/3-180A CTK-150/3-150A MTK-95/3-75 CTK-220/3-180A CTK-220/3-180A MTK-95/3-85 CTK-400/3-240A CTK-220/3-240A CTK-100/3-125A CTK-400/3-300A CTK-400/3-300A CTK-150/3-150A CTK-400/3-400A CTK-400/3-400A CTK-220/3-180A CTK-600/3-400A CTK-400/3-400A CTK-220/3-240A

Electronic

Manual Motor Starter

Motor Circuit Protector*

CRP22-3P 5A CRP22-3P 5A CRP22-3S 1.5A CRP22-3P 5A CRP22-3P 5A CRP22-3P 5A CRP22-3P 5A CRP22-3P 5A CRP22-3P 5A CRP22-3S 22A CRP22-3S 22A CRP22-3P 5A CRP22-3S 22A CRP22-3S 22A CRP22-3P 5A CRP22-3S 22A CRP22-3S 22A CRP22-3P 5A CRP22-3S 22A CRP22-3S 22A CRP22-3S 22A CRP40-3S 40A CRP40-3S 40A CRP22-3S 22A CRP40-3S 40A CRP40-3S 40A CRP22-3S 22A CRP80-3S 80A CRP80-3S 80A CRP40-3S 40A CRP80-3S 80A CRP80-3S 80A CRP40-3S 40A CRP80-3S 80A CRP80-3S 80A CRP40-3S 40A CRP80-3S 80A CRP80-3S 80A CRP80-3S 80A CRP80-3S 80A -

CMS-32HI-2.5 CMS-32HI-2.5 CMS-32HI-1.6 CMS-32HI-4 CMS-32HI-4 CMS-32HI-1.6 CMS-32HI-6 CMS-32HI-6 CMS-32HI-2.5 CMS-32HI-8 CMS-32HI-8 CMS-32HI-4 CMS-32HI-8 CMS-32HI-8 CMS-32HI-4 CMS-32HI-13 CMS-32HI-13 CMS-32HI-6 CMS-32HI-22 CMS-32HI-17 CMS-32HI-10 CMS-32HI-26 CMS-32HI-26 CMS-32HI-13 CMS-63HI-40 CMS-32HI-32 CMS-63HI-50 CMS-63HI-50 CMS-32HI-26 CMS-63HI-63 CMS-63HI-63 CMS-32HI-32 CMS-100HI-90 CMS-100HI-75 CMS-63HI-40 CMS-100HI-100 CMS-100HI-90 CMS-63HI-50 CMS-63S/H-50 CMS-63HI-63 CMS-100HI-75 CMS-100HI-90 CMS-100HI-100 -

CMS-32HI-2.5 CMS-32HI-2.5 CMS-32HI-1.6 CMS-32HI-4 CMS-32HI-4 CMS-32HI-1.6 CMS-32HI-6 CMS-32HI-6 CMS-32HI-2.5 CMS-32HI-8 CMS-32HI-8 CMS-32HI-4 CMS-32HI-8 CMS-32HI-8 CMS-32HI-4 CMS-32HI-13 CMS-32HI-10 CMS-32HI-6 CMS-32HI-22 CMS-32HI-17 CMS-32HI-8 CMS-32HI-26 CMS-32HI-26 CMS-32HI-13 CMS-63HI-40 CMS-32HI-32 CMS-32HI-17 CMS-63HI-50 CMS-63HI-50 CMS-32HI-26 CMS-63HI-63 CMS-63HI-63 CMS-32HI-32 CMS-100HI-90 CMS-100HI-75 CMS-63HI-40 CMS-100HI-100 CMS-100HI-90 CMS-63HI-50 TS250NU ATU 250 250A TS250NU ATU 250 250A CMS-63HI-63 TS400NU ATU 400 400A TS400NU ATU 400 300A CMS-100HI-75 TS400NU ATU 400 400A TS400NU ATU 400 400A CMS-100HI-90 TS800NU ATU 800 500A TS800NU ATU 800 500A CMS-100HI-100 TS800NU ATU 800 600A TS400NU ATU 400 300A TS800NU ATU 800 800A TS800NU ATU 800 800A TS400NU ATU 400 400A TS400NU ATU 400 400A

* Field wiring requires two conductors

91 89


1550 Montague Expressway San Jose, CA 95131

CERUS INDUSTRIAL 2009

Check out our NEW Pump Products on Page 46!

www.westcoastpower.com


Turn static files into dynamic content formats.