INDUSTRIAL
The Pursuit of Excellence in Motor Controls
CONTENTS Contactors pg. 5
Contactors, Overloads and Accessories Mira Contactors and Overloads
5
Orion Contactors and Overloads
11
Manual Motor Starters and Accessories . Manual Motor Starters
16
Manual Motor Starter Accessories
20
Relays, Overloads, Mini Contactors/Overloads Digital Motor Protection Relays
22
Electronic Overloads
23
Mini Contactors, Overloads & Relays
24
Mira Molded Case Circuit Breakers
Starters pg. 26
TD/TS Series Circuit Breakers & Accessories
28
Enclosed Manual Motor Starters
33
Industrial Enclosed Starters 36
Industrial Start Stop
38
Industrial Starters
42
16-21
22-25
26-33
44-59
Industrial and Pump Starter
44
Standard Pump Starter
48
Duplex Alternating Pump Starter
50
Enclosed VFD Pump Package
54
Variable Frequency Drives
pg. 60
5-15
34-43
Enclosed Starters
Pump Controls
VFDs
60-68
Micro-Single Phase C-Series VFD
60
Compact GS Series VFD
62
P-Series VFD
64
Resistors & Braking units
67
Additional Components
72-88
Line Reactors
72
Pressure Sensors
74
Soft Starts
76
Panel Components
80
SAFETY FIRST!
As with all electrical equipment, only qualified, expert personnel should perform maintenance and installation. Comply with all applicable local and national codes and laws that regulate the installation and operation of equipment and read manuals thoroughly. Use only installation manuals and not this sales brochure for installation procedures. It is up to the installer to determine product suitability for a given application. Š Product improvement is a continual process; pricing and specifications subject to change without notice. Marketing materials should not be relied upon for technical specification. Cerus, Mira, Orion, Titan and associated logos are trademarks of Cerus Industrial, Inc. All sales subject to Cerus Terms and Conditions.
MIRA Contactors and Overloads Installs in Minutes, Lasts a Lifetime 9~95 Amp Rated Models Integrated Lugs - Easy to Wire Without Additional Hardware DIN Rail Compatible Complete Line of Accessories and Adapters For Clean and Effective Installation Industry Leading 5-Year Warranty
Quality Design
Easy Mounting Accessories
Cerus MIRA contactors and overloads have been designed and tested to the world’s highest standards. Utilizing the Power Test and Technology Institute for rigorous testing, we have produced one of the world’s top performing and most durable UL listed contactor. The complete MIRA line of motor control components boasts one of the highest UL ratings attainable for interruption capacity when paired with our manual motor starters – as high as 100,000 amps interrupting.
The MIRA line includes accessories that offer easy installation, space savings and reduce overall cost. MIRA Bus bars, reversing kits, mating plates and DIN rail mounting hardware allow for comprehensive and highly flexible motor control solutions.
Performance & Reliability Our advanced design sets MIRA apart as one of the industry’s most durable line of motor controls. The combination of unique contact alloys and control of the electrical arc within the contactor extends the useful life to as many as 2.5 million electrical operations. MIRA is manufactured to ISO certified quality standards and backed by an industry leading 5-Year warranty.
INDUSTRIAL CATALOG
MIRA
Contactor Specifications 3-Pole, 9~95 Amp Contactors AC or DC Coil Voltages Frame Size Model Type Screw clamp terminals Lug terminals
NEMA Sized
32AF
63AF
95AF
MRC-9 MRC-12 MRC-18 MRC-25 MRC-32
MRC-35 MRC-40 MRC-50 MRC-63
MRC-65 MRC-75 MRC-85 MRC-95
•
•
•
•
•
•
•
•
•
•
•
•
•
-
-
-
-
-
•
•
•
•
•
•
•
•
Number of poles
3
3
3
690V
690V
690V
Conforming to IEC947-4-1
1000V
1000V
1000V
Conforming to UL, CSA
600V
Rated operational voltage, Ue Rated insulation voltage, Ui
600V
600V
Rated impulse withstand voltage, Uimp
8kV
8kV
8kV
Degree of pollution (IEC60529)
IP20
IP20
IP20
Rated operational current Ie (θ≤ 55 °C) AC-1 Ue max 690V [A] AC-3 200/240V [A]
25
25
40
40
50
55
60
70
75
100
110
135
140
11
13
18
25
32
35
40
55
63
65
75
85
95
380/400V
[A]
9
12
18
25
32
35
40
50
63
65
75
85
95
415V
[A]
9
12
18
25
32
35
40
50
63
65
75
85
95
440V
[A]
9
12
18
25
32
35
40
50
63
65
75
85
95
500V
[A]
7
12
13
22
28
30
32
43
45
60
64
75
85
690V
[A]
5
9
9
18
20
21
23
28
30
35
42
45
50
00
-
0
-
1
-
1P
2
-
-
-
3
-
UL 508 NEMA size Rated thermal current (Ith)
[A]
25
25
40
40
50
55
65
70
75
100
110
135
140
Single 115V Phase 230V
[HP]
1/2
3/4
1
2
2
2
3
3
5
5
5
7.5
10
[HP]
1.5
2
3
3
5
5
7.5
10
10
15
15
15
20
200V
[HP]
2
3
5
7.5
7.5
10
15
20
20
25
25
30
30
Three 230V Phase 460V
[HP]
3
5
7.5
10
10
15
20
25
25
30
30
40
40
[HP]
5
7.5
10
15
20
25
30
40
40
50
50
60
75
575V
[HP]
7.5
10
15
20
25
30
40
50
50
60
60
75
75
IEC947-4-1 Rated making capacity AC-3
250
Rated breaking capacity AC-3
250
200
250
200
200
Mechanical durability (M of cycles)
15
15
15
15
15
12
12
12
12
12
12
12
12
Electrical life for Ie/AC-3 max (M of cycles)
2.5
2.5
2.5
2.5
2.5
2
2
2
2
2
2
2
2
1800
1800
1800
1800
1800
1200
1200
1200
1200
1200
1200
1200
1200
Maximum cycles per hour AC control coil voltage operated contactors Weight Dimensions (W x H x D) Coil Consumption
[lbs]
0.99
2.07
4.00
[in]
1.77 x 3.27 x 3.66
2.17 X 4.17 X 4.80
2.76 X 5.51 X 5.39
Inrush [VA]
80
120
220
Holding [VA]
9
7
16
DC control coil voltage operated contactors Weight Dimensions (W x H x D) Coil Consumption
6
[lbs]
1.39
2.64
5.94
[in]
1.77 x 3.27 x 4.65
2.17 X 4.17 X 6.32
2.76 X 5.51 X 6.79
Inrush [VA]
7
9
18
Holding [VA]
7
9
18
www.westcoastpower.com 1-866-955-0888
CONTACTORS & OVERLOADS
MIRA
Overload Specifications 9~95 Amp Overloads Differential Class 10 Relay type
MTK-32
MTK-63
MTK-95
Tripping class (IEC 60947-4-1)
10
10
10
10
10
Number of poles
3
3
3
3
3
Up to 690V
Up to 690V
Up to 690V
Up to 690V
Up to 690V
690V
690V
690V
690V
690V
Rated operational voltage (Ue) Rated insulation voltage (Ui) Rated impulse voltage (Uimp) Temperature compensation °C Dimensions (W x H x D) [in]
6kV
6kV
6kV
6kV
6kV
-5 ~ 40
-5 ~ 40
-5 ~ 40
-5 ~ 40
-5 ~ 40
0.31
0.48
2.1 x 1.8 x 3.4
Weight (kg)
0.17
2.8 x 2.2 x 3.8 0.31
3.3 x 2.8 x 4.2 0.48
Functions Differential, Phase Failure
•
•
•
•
•
Trip Indicating
•
•
•
•
•
Stop
•
•
•
•
•
Test
•
•
•
•
•
Manual/Automatic Reset
•
•
•
•
•
Screw clamp
Screw
Lug
Screw
Lug
Terminal type
TM
NEMA Sized
2.5 Million Up to 95A
Standards Electric Life Matching UL Type F MMS Auxilary Contacts Spring Loaded Screw Terminals Safety Cover 5 Year Warranty
TM
NEMA Sized
Standards Electric Life
ALLEN BRADLEY
Matching UL Type F MMS
1.3 Million Up to 63A
Auxilary Contacts Spring Loaded Screw Terminals Safety Cover 5 Year Warranty NEMA Sized
TM
Standards Electric Life Matching UL Type F MMS
1.5 Million Up to 63A
Auxilary Contacts Spring Loaded Screw Terminals Safety Cover 5 Year Warranty *These comparisons are based on published marketing information from manufacturers. If any company or their representative notices a factual discrepancy, please contact Cerus to ensure accuracy and timely correction. Allen-Bradley and Square D are trademarks of their respective companies and these companies are not affiliates of Cerus Industrial.
7
INDUSTRIAL CATALOG
MIRA Contactors & Overload Relays Contactors
32AF Horsepower
Motor Voltage 115V
1/2
3/4
1
2
230V
1.5
2
3
3
5
200V
2
3
5
7.5
7.5
230V
3
5
7.5
10
10
460V
5
7.5
10
15
20
575V
7.5
10
15
20
25
NEMA Size
00
0
-
1
Single Phase
Three Phase
Finger safe terminals Interchangeable replacement coils Standard 1NO/1NC auxiliary contacts
2
AC Contactors
MRC-9
MRC-12
MRC-18
MRC-25
MRC-32
DC Contactors
MRD-9
MRD-12
MRD-18
MRD-25
MRD-32
Reversing Kits
MR-02
MR-02
MR-02
MR-02
MR-02
UW-32
UW-32
UW-32
UW-32
UW-32
Overload Relays
32AF
Mounts directly to MIRA contactors Differential thermal protection detects phase loss Adjustable current setting, Hand or Auto reset
Setting Range
Part Number
0.1~0.16
MTK-32/3-0.16
0.1~0.25
MTK-32/3-0.25
0.25~0.4
MTK-32/3-0.4
0.4~0.63
MTK-32/3-0.63
0.63~1
MTK-32/3-1
1~1.6
MTK-32/-3-1.6
1.6~2.5
MTK-32/3-2.5
2.5~4
MTK-32/3-4
4~6
MTK-32/3-6
5~8
MTK-32/3-8
6~9
MTK-32/3-9
7~10
MTK-32/3-10
12~18
MTK-32/3-18
16~22
MTK-32/3-22
18~25
MTK-32/3-25
22~32
MTK-32/3-32
Coil Voltage Options AC Coil Voltages DC Coil Voltages
8
Voltage
24VAC
120VAC
Frequency
50/60Hz
Voltage
12VDC
www.westcoastpower.com 1-866-955-0888
208VAC
220VAC
240VAC
277VAC
380VAC
480VAC
600VAC
50/60Hz
60Hz
50/60Hz
50/60Hz
60Hz
50/60Hz
60Hz
60Hz
24VDC
48VDC
110VDC
CONTACTORS & OVERLOADS
63AF Horsepower
95AF Horsepower
2
3
3
5
5
5
7.5
10
5
7.5
10
10
15
15
15
20
10
15
20
20
25
25
30
30
15
20
25
25
30
30
40
40
25
30
40
40
50
50
60
75
30
40
50
50
60
60
75
75
-
-
2
-
-
-
3
-
MRC-35L
MRC-40L
MRC-50L
MRC-63L
MRC-65L
MRC-75L
MRC-85L
MRC-95L
MRD-35L
MRD-40L
MRD-50L
MRD-63L
MRD-65L
MRD-75L
MRD-85L
MRD-95L
MR-02
MR-02
MR-02
MR-02
MR-02
MR-02
MR-02
MR-02
UW-63
UW-63
UW-63
UW-63
UW-95
UW-95
UW-95
UW-95
63AF
95AF
Setting Range
Part Number
Relay Setting Range
Part Number
4~6
MTK-63/3-6L
7~10
MTK-95/3-10L
5~8
MTK-63/3-8L
9~13
MTK-95/3-13L
6~9
MTK-63/3-9L
12~18
MTK-95/3-18L
7~10
MTK-63/3-10L
16~22
MTK-95/3-22L
9~13
MTK-63/3-13L
18~25
MTK-95/3-25L
12~18
MTK-63/3-18L
24~36
MTK-95/3-36L
16~22
MTK-63/3-22L
28~40
MTK-95/3-40L
18~25
MTK-63/3-25L
34~50
MTK-95/3-50L
24~36
MTK-63/3-36L
45~65
MTK-95/3-65L
28~40
MTK-63/3-40L
54~75
MTK-95/3-75L
34~50
MTK-63/3-50L
63~85
MTK-95/3-85L
45~65
MTK-63/3-65L
70~95
MTK-95/3-95L
Auxiliary Contacts Description
Part Number
Side mount
MA-1 (1NO & 1NC)
Top mount
CA-2 (Specify 2NO, 2NC, or 1NO & 1NC)
Top mount
CA-4 (Specify 4NO, 4NC, 2NO & 2NC, 3NO & 1NC, or 1NO & 3NC)
9
INDUSTRIAL CATALOG
MIRA
Accessories Replacement AC Contactor Coils Frame Size
9-32
35-63
Coil Voltage
Mechanical and Electrical Interlock
Part Number
Frame Size
Part Number
32AF~95AF
MR-02
MC9-32 240V 50/60HZ
Frame Size
Part Number
277VAC
MC9-32 277V 60HZ
32AF~63AF
AC-9
380VAC
MC9-32 380V 50/60HZ
95AF
AC-50
480VAC
MC9-32 480V 60HZ
Voltage
Part Number
24VAC
MC9-32 24V 50/60HZ
48VAC
MC9-32 48V 50/60HZ
120VAC
MC9-32 120V 50/60HZ
208VAC
MC9-32 208V 60HZ
220VAC
MC9-32 220V 50/60HZ
240VAC
Capacitor Auxiliary Units
600VAC
MC9-32 600V 60HZ
24VAC
MC35-63 24V 50/60HZ
48VAC
MC35-63 48V 50/60HZ
120VAC
MC35-63120V 50/60HZ
208VAC
MC35-63 208V 60HZ
24-48VAC
MS-1
220VAC
MC35-63 220V 50/60HZ
100-125VAC
MS-2
240VAC
MC35-63 240V 50/60HZ
200-240VAC
MS-3
277VAC
MC35-63 277V 60HZ
24-48VDC
MS-4
380VAC
MC35-63 380V 50/60HZ
100-125VDC
MS-5
MC35-63 480V 60HZ
200-220VDC
MS-6
MC35-63 600V 60HZ
24-48VAC/VDC
MS-11
100-125VAC/VDC
MS-12
200-240VAC/VDC
MS-13
380-440VAC/VDC
MS-14
480VAC 600VAC
AC/DC Surge Suppressor
Mechanical Latch Unit Voltage AC Operated Units
Replacement DC Contactor Coils Frame Size
9-32
35-63
65-95
10
Coil Voltage
Part Number
12VDC
MC9-32 12VDC
24VDC
MC9-32 24VDC
48VDC
MC9-32 48VDC
110VDC
MC9-32 110VDC
12VDC
MC35-63 12VDC
24VDC
MC35-63 24VDC
48VDC
MC35-63 48VDC
110VDC
MC35-63 110VDC
12VDC
MC65-95 12VDC
24VDC
MC65-95 24VDC
48VDC
MC65-95 48VDC
110VDC
MC65-95 110VDC
www.westcoastpower.com 1-866-955-0888
DC Operated Units
Part Number
100~127V 50/60Hz
AL-9 100VAC
200~240V 50/60Hz
AL-9 200VAC
460~500V 50/60Hz
AL-9 500VAC
100~127V 50/60Hz
AL-50 100VAC
200~240V 50/60Hz
AL-50 200VAC
460~500V 50/60Hz
AL-50 500VAC
DC24V
AL-9 24VDC
DC24V
AL-50 24VDC
DIN Rail Adapters Frame Size
Part Number
32AF
UZ-32
63AF
UZ-63/L
63AF
UZ-63/S
95AF
UZ-95/L
95AF
UZ-95/S
ORION Contactors and Overloads Installs in Minutes, Lasts a Lifetime
100~800 Amp Rated Models High Reliability: Up to 25 Million Cycles Superior Value Our Contactors Are Among the Highest Rated in the Industry for UL Sizes. 5-Year Warranty
“We like the flexibility of Orion contactors. Their universal coils are unique because they accept a wide range of voltages – I don’t have to stock a bunch of different sized coils.”
INDUSTRIAL CATALOG
ORION
Contactor Specifications 100~800 Amp Contactors Wide Range, Common Coils (AC & DC)
NEMA Sized
Quiet, Reliable Switching For Tough Applications
Long-term reliability thanks to large contact surface areas, advanced metallurgy and oversized magnetics Among the highest current ratings in the industry for UL sizes Heavy -duty construction eliminates buzzing and poor switching Electronic coil reduces in-rush and holding current, integrates protective surge suppression and prevents coil failures due to mechanical faults.
Reduced Inventory Carrying Costs Pre-installed auxiliary contacts included standard with each contactor (2NO & 2NC) Wide voltage range AC/DC coil reduces inventory and offers flexible installation solutions
Frame Size
100AF
Model
CRC-100
Number of poles Rated operational voltage, Ue
150AF
CRC-125
CRC-150
220AF CRC-180
400AF
CRC-220
CRC-300
600AF
CRC-400
CRC-600
CRC-800
3
3
3
3
3
690V
690V
690V
690V
690V
Rated operational current Ie (θ≤ 55 °C) AC-1 AC-3
Ue max 690V
[A]
150
150
200
230
260
350
420
660
900
200/240V
[A]
105
125
150
180
250
300
400
630
800
380/440V
[A]
105
120
150
180
250
300
400
630
800
500V/550V
[A]
85
90
140
180
200
250
350
500
720
690V
[A]
65
70
100
120
150
220
300
420
630
-
-
4
-
-
5
-
6
-
[A]
160
160
210
230
275
350
450
660
900
[HP]
7.5
10
15
15
15
-
-
-
-
UL 508 NEMA size Rated thermal current (Ith) Single Phase
Three Phase
115V 230V
[HP]
15
20
25
30
40
-
-
-
-
200V
[HP]
30
40
40
60
60
100
125
150
250
230V
[HP]
30
40
50
60
75
100
150
200
300
460V
[HP]
60
75
100
125
150
200
300
400
600
575V
[HP]
60
75
100
125
150
200
300
400
600
AC/DC control coil voltage operated contactors Weight Dimensions (W x H x D) Coil Consumption
12
[lbs]
6.7
7.9
13.5
22
52
[in]
3.9 x 6.5 x 5.8
4.7 x 6.9 x 6.2
5.4 x 8.0 x 7.1
6.4 x 9.6 x 7.8
11.2 x 12.3 x 9.5
Inrush [VA]
220
393
1000
Holding [VA]
9.1
14
17
www.westcoastpower.com 1-866-955-0888
CONTACTORS & OVERLOADS
ORION
Overload Specifications 100~800 Amp Overloads Differential Class 10
Thermal Overload Options
Mounts directly to contactor or standalone (screw mount) Overload includes NO & NC trip contacts Differential phase failure protection Ambient compensated (-5º to 40ºC)
Easy Installation Thermal overload relays matched for simple, direct connection with busbars Standard 1NO & 1NC auxiliary contacts on each overload relay Optional finger-proof safety covers
Frame Size
CTK-100
CTK-150
CTK-220
CTK-400
CTK-600
Tripping class (IEC 60947-4-1)
10
10
10
10
10
Number of poles
3
3
3
3
3
Up to 690V
Up to 690V
Up to 690V
Up to 690V
Up to 690V
690V
690V
690V
690V
690V
Rated operational voltage (Ue) Rated insulation voltage (Ui) Rated impulse voltage (Uimp)
6kV
6kV
6kV
6kV
6kV
-5 ~ 40
-5 ~ 40
-5 ~ 40
-5 ~ 40
-5 ~ 40
1.4
1.8
5.9
7
30
Differential, Phase Failure
•
•
•
•
•
Trip Indicating
•
•
•
•
•
Stop
•
•
•
•
•
Test
•
•
•
•
•
Temperature compensation °C Weight [lbs] Functions
Manual/Automatic Reset Terminal type
•
•
•
•
•
Screw
Screw
Screw
Screw
Screw
13
INDUSTRIAL CATALOG
ORION Contactors & Overload Relays Contactors
100AF
150AF
220AF
400AF
800AF
HP
HP
HP
HP
HP
Motor Voltage
100 100 200 200 5
125 150 300 300
150 200 400 400 6
200 300 600 600
CRC-220
CRC-300
CRC-400
CRC-600
CRC-800
AJ-220
AJ-220
AJ-400
AJ-400
AJ-600
AJ-600
AR-100
AR-180
AR-180
AR-180
AR-180
AR-600
AR-600
CRC-150R
CRC-220R
CRC-220R
CRC-400R
CRC-400R
-
-
115V
7.5
10
15
15
16
230V
15
20
25
30
40
200V
30
40
40
60
60
230V
30
40
50
60
75
460V
60
75
100
125
150
575V
60
75
100
125
150
CRC-100
CRC-125
CRC-150
CRC-180
Contactor Lug Kits*
AJ-125
AJ-125
AJ-150
Reversing Kits*
AR-100
AR-100 CRC-100R
Single Phase
Three Phase
NEMA Size AC/DC Contactors
4
CRC-100R
Overload Relays
100AF
150AF
220AF
400AF
Setting Range
Part Number
34-50
CTK-100/3-50
CTK-150/3-50
39-57
CTK-100/3-57
CTK-150/3-57
43-65
CTK-100/3-65
CTK-150/3-65
54-80
CTK-100/3-80
CTK-150/3-80
65-100
CTK-100/3-100
CTK-150/3-100
CTK-220/3-100
85-125
CTK-100/3-125
CTK-150/3-125
CTK-220/3-125
CTK-400/3-125
CTK-150/3-150
-
-
100-160
CTK-220/3-160
CTK-400/3-160
120-180
CTK-220/3-180
CTK-400/3-180
160-240
CTK-220/3-240
CTK-400/3-240
100-150
220-300
CTK-400/3-300
260-400
CTK-400/3-400
800AF
200-300
CTK-600/3-300
260-400
CTK-600/3-400
400-600
CTK-600/3-600
520-800
CTK-600/3-800
*Products ship disassembled. ‥For 4-Pole configurations consult factory.
Reversing assemblies are easy with the Orion Series Reversing Kit which includes adapter plate and mechanical interlock.
14
www.westcoastpower.com 1-866-955-0888
CONTACTORS & OVERLOADS
ORION
Accessories Latching Units AC Coil Operated Units
Surge Suppressors Voltage
Part Number
0~48VAC/DC
AS-11
AL-100 100VAC
48~120VAC/DC
AS-12
AL-100 200VAC
120~240VAC/DC
AS-13
Voltage
Frame Size
Part Number
100~127V 50/60Hz
100AF
200~240V 50/60Hz
100AF
460~550V 50/60Hz
100AF
AL-100 500VAC
100~127V 50/60Hz
150AF
AL-150 100VAC
200~240V 50/60Hz
150AF
AL-150 200VAC
460~550V 50/60Hz
150AF
AL-150 500VAC
100~127V 50/60Hz
220AF
AL-180 100VAC
200~240V 50/60Hz
220AF
AL-180 200VAC
460~550V 50/60Hz
220AF
AL-180 500VAC
100~127V 50/60Hz
400AF
AL-400 100VAC
200~240V 50/60Hz
400AF
AL-400 200VAC
460~550V 50/60Hz
400AF
AL-400 500VAC
DC Coil Operated Units Voltage
Frame Size
Part Number
DC24V
100AF
AL-100 24VDC
DC24V
150AF
AL-150 24VDC
DC24V
220AF
AL-180 24VDC
DC24V
400AF
AL-400 24VDC
Terminal Cover Units Frame Size
Part Number
100AF
AP-100/125
150AF
AP-150
220AF
AP-180/220
400AF
AP-300/400
600AF
AP-600/800
100AF
APT-100
150AF
APT-150
220AF
APT-220
400AF
APT-400
600AF
APT-600
Replacement Contactor Coils Voltage
Frame Size
24-25V
100AF & 150AF
CRC150C-24V
Part Number
100-240V
100AF & 150AF
CRC150C-100-200V
440-575V
100AF & 150AF
CRC150C-500V*
24-25V
220AF
CRC220C-24V
100-240V
220AF
CRC220C-100-200V
440-575V
220AF
CRC220C-500V*
100-240V
400AF
CRC400C-100-200V
440-575V
400AF
CRC400C-500V*
100-127V
600AF
CRC800C-100V
200-240V
600AF
CRC800C-200V
440-575V
600AF
CRC800C-500V*
The Orion contactor’s standard electronic coil accepts either AC or DC voltages.
*AC Coil Voltage only
15
MIRA Manual Motor Starters The OEM Solution for Motor Controls Compact Design High Interruption Capacity Reduces Overall Installed Cost 32~100 Amp Frame Sizes
The Cerus MMS insulated busbar system allows you to feed several modular circuit breakers on a standard mounting rail.
“We saved money and space by installing Cerus Manual Motor Starters which eliminated costly fuse blocks for branch protection in our multimotor control panels.”
Up to 100,000 Amps Short Circuit Interrupting Current Rating Available in Standard & High-Break Versions Lockable Handle Operator and Finger Safe Terminals Exceeds UL Standards for Group and Combination Motor Applications (UL Type E & F Ratings with Cerus MIRA Contactors) Universal Accessories Reduce Inventory Optional Waterproof Enclosure Quality Design Carefully engineered to improve reliability, the advanced flexibility of MIRA components allow for seamless integration with Cerus’ Manual Motor Starters (MMS) and accessories. With coordinated ratings as a combination starter meeting both UL and IEC Type 2 standards, the MIRA design provides an unbeatable combination reducing installation costs and saving valuable panel space. High Reliability Only contactors and breakers tested to UL standards as a unit can achieve the highest coordinated interrupt ratings. Cerus MMS carry UL Type E and F ratings when paired with MIRA contactors meeting standards for both group motor protection and self-protection when used as a combination starter.
Easy Mounting Accessories Cerus MMS have a full range of optional accessories including base plates, auxiliary contacts, alarm switches, shunts and under voltage releases. The simplified mounting of the Cerus MMS allows for fast and easy integration with bus bars and MIRA contactors.
INDUSTRIAL CATALOG
Manual Motor Starters
CMS-32S
32~100 Amp Frame Sizes Standard & High Break Adjustable Thermal or Magnetic Trip
Thermal Magnetic Rated Release Release Operational Adjustment Operating Current (A) Range (A) Current (A)
32 AF Manual Motor Starters 0.16 0.1-0.16 2.1 0.25 0.16-0.25 3.3 0.4 0.25-0.4 5.2 0.63 0.4-0.63 8.2 1 0.63-1 13 1.6 1-1.6 20.8 2.5 1.6-2.5 32.5 4 2.5-4 52 6 4-6 78 8 5-8 104 10 6-10 130 13 9-13 169 17 11-17 221 22 14-22 286 26 18-26 338 32 22-32 416 63 AF Manual Motor Starters 10 6-10 130 13 9-13 169 17 11-17 221 22 14-22 286 26 18-26 338 32 22-32 416 40 28-40 520 50 34-50 650 63 45-63 819 100 AF Manual Motor Starters 17 11-17 221 22 14-22 286 26 18-26 338 32 22-32 416 40 28-40 520 50 34-50 650 63 45-63 819 75 55-75 975 90 70-90 1170 100 80-100 1300
CMS-32H
H=3.70”
H=3.70”
D=2.95”
D=5.69”
W=1.77”
W=2.17”
Standard Trip‡
Horsepower Three Phase
SCIC (kA)*
Part Number
115V
230V
200V
230V
460V
575V
240V kA
480V kA
600V kA
1/8 1/4 1/3 1/2 1/2 1 1.5 2 2
1/10 1/6 1/3 1/2 1 1.5 2 3 3 3 5
1/2 3/4 1 2 2 3 3 5 7.5 7.5
1/2 3/4 1.5 2 3 3 5 7.5 7.5 10
3/4 1 2 3 5 5 7.5 10 15 15 20
1/2 3/4 1.5 3 5 5 7.5 10 15 20 20 30
100 100 100 100 100 100 100 100 100 100 50 50 40 30 30 20
50 50 50 50 50 50 50 50 25 25 10 10 10 10 7.5 7.5
10 10 10 10 10 10 10 5 5 5 5 5 5 5 5 5
CMS-32S-0.16 CMS-32S-0.25 CMS-32S-0.4 CMS-32S-0.63 CMS-32S-1 CMS-32S-1.6 CMS-32S-2.5 CMS-32S-4 CMS-32S-6 CMS-32S-8 CMS-32S-10 CMS-32S-13 CMS-32S-17 CMS-32S-22 CMS-32S-26 CMS-32S-32
1/2 1/2 1 1.5 2 2 3 3 5
1.5 2 3 3 3 5 7.5 10 10
2 3 3 5 7.5 7.5 10 15 20
3 3 5 7.5 7.5 10 10 15 20
5 7.5 10 15 15 20 30 30 40
7.5 10 15 20 20 30 30 40 60
100 100 100 100 100 100 100 100 100
50 50 40 40 40 40 40 40 40
10 10 10 10 10 10 10 10 10
CMS-63S-10 CMS-63S-13 CMS-63S-17 CMS-63S-22 CMS-63S-26 CMS-63S-32 CMS-63S-40 CMS-63S-50 CMS-63S-63
1 1.5 2 2 3 3 5 5 7.5 10
3 3 3 5 7.5 10 10 15 20 20
3 5 7.5 7.5 10 15 20 20 25 30
5 7.5 7.5 10 10 15 20 25 30 30
10 15 15 20 30 30 40 50 60 75
15 20 20 30 30 40 60 60 75 100
100 100 100 100 100 100 100 100 100 100
50 50 50 50 50 50 40 40 40 40
10 10 10 10 10 10 10 10 10 10
CMS-100S-17 CMS-100S-22 CMS-100S-26 CMS-100S-32 CMS-100S-40 CMS-100S-50 CMS-100S-63 CMS-100S-75 CMS-100S-90 CMS-100S-100
* UL ratings for combination manual motor controller with Cerus Mira contactors. ‡ CMS-32S are UL listed as a manual motor controller only, and are not UL Type E, manual self-protected combination motor controller.
18
H=5.51”
D=3.90”
W=1.77”
Single Phase
CMS-63H
www.westcoastpower.com 1-866-955-0888
MANUAL MOTOR STARTERS
CMS-100H
Differential Class 10 Thermal Overload Phase Failure Protection Ambient Temperature Compensation
H=6.50” D=6.73” W=2.76”
High Break Trip SCIC (kA)
Magnetic Trip Only Part Number
Part Number
240V kA
480V kA
600V kA
100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100
65 65 65 65 65 65 65 65 65 65 65 65 30 30 30 30
25 25 25 25 25 25 25 25 25 25 25 25 10 10 10 10
CMS-32H-0.16 CMS-32H-0.25 CMS-32H-0.4 CMS-32H-0.63 CMS-32H-1 CMS-32H-1.6 CMS-32H-2.5 CMS-32H-4 CMS-32H-6 CMS-32H-8 CMS-32H-10 CMS-32H-13 CMS-32H-17 CMS-32H-22 CMS-32H-26 CMS-32H-32
CMS-32HI-0.16 CMS-32HI-0.25 CMS-32HI-0.4 CMS-32HI-0.63 CMS-32HI-1 CMS-32HI-1.6 CMS-32HI-2.5 CMS-32HI-4 CMS-32HI-6 CMS-32HI-8 CMS-32HI-10 CMS-32HI-13 CMS-32HI-17 CMS-32HI-22 CMS-32HI-26 CMS-32HI-32
100 100 100 100 100 100 100 100 100
65 65 50 50 50 50 50 50 50
25 25 10 10 10 10 10 10 10
CMS-63H-10 CMS-63H-13 CMS-63H-17 CMS-63H-22 CMS-63H-26 CMS-63H-32 CMS-63H-40 CMS-63H-50 CMS-63H-63
CMS-63HI-10 CMS-63HI-13 CMS-63HI-17 CMS-63HI-22 CMS-63HI-26 CMS-63HI-32 CMS-63HI-40 CMS-63HI-50 CMS-63HI-63
100 100 100 100 100 100 100 100 100 100
65 65 65 65 65 65 50 50 50 50
25 20 20 20 20 20 10 10 10 10
CMS-100H-17 CMS-100H-22 CMS-100H-26 CMS-100H-32 CMS-100H-40 CMS-100H-50 CMS-100H-63 CMS-100H-75 CMS-100H-90 CMS-100H-100
CMS-100HI-17 CMS-100HI-22 CMS-100HI-26 CMS-100HI-32 CMS-100HI-40 CMS-100HI-50 CMS-100HI-63 CMS-100HI-75 CMS-100HI-90 CMS-100HI-100
19
INDUSTRIAL CATALOG
Manual Motor Starter Accessories MMS Auxiliaries Part Number
Description Front Auxiliary Switch
FX-1NO-1NC
Side Auxiliary Switch
LX-1NO-1NC
Magnetic Trip Alarm Switch
LAM-1NO-1NC
Any Trip Alarm Switch
LA-1NO-1NC (32AF size only)
Shunt Release
RS-(specify voltage rating using chart below)
Undervoltage Release
RU-(specify voltage rating using chart below)
Undervoltage Release with Auxiliary (2NO)
RUX-(specify voltage rating using chart below)
AC Voltage
28VAC
120VAC
260VAC
480VAC
Frequency/ Range
24V @ 50Hz 28V @ 60Hz
110-127V @ 50Hz 120V @ 60Hz
220-230V @ 50Hz 240-260V @ 60Hz
415-440V @ 50Hz 460-480V @ 60Hz
Front Auxiliary Switch Front mounting 2-pole (1NO, 1NC) One front mounting module per circuit breaker
20
Side Auxiliary Switch & Magnetic Trip Alarm Switch
Shunt Release & Undervoltage Release with Auxiliary (2NO)
Side mounting on the left 2-pole (1NO, 1NC) One side mounting module per circuit breaker (Always directly fitted to the circuit breaker except using with Any Trip Alarm Switch)
Side mounting on the right One side mounting module per circuit breaker (Always directly fitted to the circuit breaker)
www.westcoastpower.com 1-866-955-0888
MANUAL MOTOR STARTERS
Manual Motor Starter Accessories IP65 Enclosure (NEMA 4X)
Frame Size
Part Number
32AF
CI-EPH32-65S
Rugged, heavy-duty impact-resistant plastic case Rotary switch includes lockable handle for up to 3 padlocks Convenient standard knockouts for easy installation Incorporates neutral and ground busbars for easy wiring
Through the Door Operator Frame Size Shaft Length
Door i nterlocking mechanism (defeatable) Accommodates up to 3 padlocks for lockout Available in 115mm & 315mm shaft lengths
Part Number CI-MEH-32/115
32AF
115
63AF
115
CI-MEH-63/115
95AF
115
CI-MEH-100/115
32AF
315
CI-MEH-32/315
63AF
315
CI-MEH-63/315
95AF
315
CI-MEH-100/315
Frame Size
Description
Part Number
32AF
2-Position
CPB-322
63AF
2-Position
CPB-632
32AF
3-Position
CPB-323
Phase Bus Devices
Insulated bus-bar system Feed several modular circuit Reduce wiring and feed multiple manual breakers on standard mounting rails motor starters Space saving, easy installation
63AF
3-Position
CPB-633
32AF
Plastic Cover
CPBPC-32
63AF
Plastic Cover
CPBPC-63
MMS Direct Adapters & Mounting Units AC Operated Units
DC Operated Units
Direct Adapter and Mounting Unit allow complete integration of Manual Motor Starter and Contactor Reduce labor associated with wiring and mounting components
Mounting Units
Frame Size
Part Number
32AF
DA-32SA
32AF
DA-32HA
63AF
DA-63A
95AF
DA-95A
Frame Size
Part Number
32AF
DA-32SD
32AF
DA-32HD
63AF
DA-63D
95AF
DA-95D
Frame Size
Part Number
32AF
MU-45
63AF
MU-55
95AF
MU-70
21
INDUSTRIAL CATALOG
Digital Motor Protection Relays 0.5~60A Adjustable Class 1-60 LED Display
Complete Motor Protection & Monitoring
Versatile Installation
E xcellent motor protection against under/over-current, stall, phase failure, phase unbalance and phase reversal Ground fault and instantaneous short circuit options Inverse time or definite time limit selection for precise control of trip characteristics LED display indicates fault type
R emovable terminal base allows integrated display to be door-mounted with cable extension Screw or tunnel-type models available
Digital Motor Protection Relays & Accessories Specifications Wiring Connection Mounting Panel Mount Display Trip time curve Reset Display Alarm Current setting ranges Insulation resistance Surge impulse voltage (IEC1000-4-5) Trip Class Inverse trip delay Overcurrent Undercurrent Phase Failure Phase Unbalance Protective Functions Phase Reversal Stall Locked rotor Ground fault Start delay Definite Time Settings Operating delay Current Tolerance Time Voltage Operating Power Frequency Overload (2-SPST) Auxiliary Contacts Alarm (SPST) Operating Temperature Operating Storage Temperature Environment Humidity
Setting Range Screw or tunnel 35mm DIN or screw mount On unit or with cable extension Inverse curve/Definite time Manual Reset LED & Bar-graph Variable (60-110% of the setting current) 0.5-6A, 5-60A Over DC 500V 100Ω 1.2 x 50μs 6kV (apply standard wave form) Class 1-60 Adjustable 3 seconds 3 seconds 5 seconds Within 0.1 seconds 5 seconds Within 0.5 seconds 0.05~1 second 0-60 seconds 0-30 seconds ±5% ±5% (or ±0.5 sec.) AC 110-120V 60Hz (50Hz) 3A/250VAC resistive load 3A/250VAC resistive load -25° ~ 60°C -30° ~ 70°C 30-90% Relative Humidity (non-condensing)
Connection
Part Number*
0.5-6A
Screw Terminals
CDP06-S
5-60A
Screw Terminals
CDP60-S
0.5-6A
Tunnel
CDP06-T
5-60A
Tunnel
CDP60-T
DMPR Accessories Description
Part Number* ZCT D30 (30mm opening) ZCT D50 (50mm opening)
Ground Fault Current Sensor
ZCT D65 (65mm opening) ZCT D80 (80mm opening) CDP-CABLE-1M (1 meter)
Remote Mounting Cable
CDP-CABLE-2M (2 meter) CDP-CABLE-3M (3 meter)
* For ground fault detection, part number is followed with “Z” and requires a current sensor selected from table above.
Under current
Reverse phase
Phase fall
Ground fault
Stall
Short circuit
Lock
Fault conditions are clearly displayed on the DMPR’s 7-segment LED interface.
22
www.westcoastpower.com 1-866-955-0888
RELAYS, OVERLOADS, MINI CONTACTORS
Electronic Overloads 0.3~80A Adjustable Class 1-30 Microprocessor Based
Phase Protection
Specifications Wiring Connection Mounting Trip time curve Reset
P hase current unbalance: trips within 5 seconds when the phase current unbalance exceeds 50% Phase loss/phase failure: trips within 3 seconds when phase current is 70% unbalanced Phase reversal: trips within 1 second in the event of reverse phase current or mis-wiring Wide range current adjustment and Class1-30 adjustment fits any application
Display Trip Class
Protective Functions
Easy Installation Tolerance
Mounts to 35mm DIN-Rail through screw terminals and tunnel type terminal in single unit
Operating Power
Fully Adjustable Overload Relay Three models cover ¼ HP to 60 HP for reduced stocking and flexibility 1-5A range can be used with external CTs to cover applications over 80A Built-in stall protection provides maximum protection to the motor (trips at 170% of full load amps at 3 seconds)
Auxiliary Contacts Operating Environment
Current setting ranges Inverse trip delay Overcurrent Phase Failure Phase Unbalance Phase Reversal Stall Current Time Voltage Frequency Contact Ratings Operation Operating Temperature Storage Temperature Humidity
Screw, tunnel or pin 35mm DIN, screw or direct Inverse curve Manual Reset Trip LED indicator 0.3-80A, Model specific Class 1-30 Adjustable 3 seconds 5 seconds Optional 5 seconds ±5% ±5% (or ±0.5 sec.) AC 100-260V 50Hz/60Hz 2 SPDT (when power applied) 3A/250VAC resistive load 1 N.O. & 1 N.C. -25° ~ 60°C -30° ~ 70°C 30-90% Relative Humidity (non-condensing)
Electronic Overloads Connections
Mounting
Part Number
Setting Range
Pin
Direct
CRP22-3P-
0.3-1.5A 1-5A 4.4-22A
Screw
DIN/Screw
CRP22-3S-
Tunnel
DIN/Screw
CRP22-3T-
Pin
Direct
CRP40-3P-
Screw
DIN/Screw
CRP40-3S-
Tunnel
DIN/Screw
CRP40-3T-
Screw
Direct/DIN/Screw
CRP80-3S-
Current Setting - Amp range varies based on model selected Trip Class Setting - 1 to 30 seconds LED Indicator
4-20A 8-40A 16-80A
Status Indication - Normal - Overload - Phase Unbalance Fault Indication - Overcurrent - Phase loss - Reverse phase
Test/Reset Button
23
INDUSTRIAL CATALOG
Mini-Contactors & Overloads 6~12A, 3-Pole Standard & Reversing 35mm DIN or Screw Mount
Economical, Compact & Reliable - The Perfect OEM Solution!
PLC compatible coils with lower holding current for cool operation Available thermal overloads attach without brackets Standard mounting wither with screws or on 35mm DIN rail Pre-assembled and wired reversing
Economical open starter package pre-wired for contactor coil operation Wide selection of coil voltages
Coil Voltage Options
6A~12A Mini-Contactors Rated Thermal Current 115V Motor Voltage 230V 200V 230V 460V 575V AC Contactors DC Contactors AC Reversing DC Reversing
6A
9A
12A
20 1/2 1/3 1/4 1/5 1/6 1/7 CMC-6M CMD-6M CMC-6MR CMD-6MR
20 1/2 1.5 3 3 5 10 CMC-9M CMD-9M CMC-9MR CMD-9MR
20 1 2 3 3 7.5 15 CMC-12M CMD-12M CMC-12MR CMD-12MR
Setting Range
Overload Relays
24
0.1~0.16 0.16~0.25 0.25~0.4 0.4~0.63 0.63~1 1~1.6 1.6~2.5 2.5~4 4~6 5~8 6~9 7~10 9~13 12~16
Part Number CTK-12M/3-0.16 CTK-12M/ 3-0.25 CTK-12M/ 3-0.4 CTK-12M/ 3-0.63 CTK-12M/ 3-1 CTK-12M/ 3-1.6 CTK-12M/ 3-2.5 CTK-12M/ 3-4 CTK-12M/ 3-6 CTK-12M/ 3-8 CTK-12M/ 3-9 CTK-12M/ 3-10 CTK-12M/ 3-13 CTK-12M/ 3-16
www.westcoastpower.com 1-866-955-0888
AC Voltages DC Voltages
Voltage
24VAC
120VAC
240VAC
480VAC
Frequency
50/60Hz
50/60Hz
60Hz
60Hz
Voltage
12V
24V
48V
Auxiliary Contacts Description 2-Pole Auxiliaries (Top Mount)
Part Number CA-2M (1NO, 1NC) CA-2M (2NO) CA-2M (2NC) CA-4M (2NO, 2NC)
4-Pole Auxiliaries (Top Mount)
CA-4M (3NO, 1NC) CA-4M (4NO) CA-4M (4NC)
RELAYS, OVERLOADS, MINI CONTACTORS
Mini-Contactor Control Relays 4, 6 & 8-Pole Units 16 Amp Rated Standard 44mm Size
Expandable up to 8-Pole Select DPDT, 3PDT or 4PDT variations 44mm wide Finger proof design
16A continuous current, Ith DIN rail or screw mountable AC/DC control voltage
Specifications Rated Current
Contact Ratings
AC Duty
DC Duty
Making/Braking Current
Inductive Load Resistive Load Inductive Load Resistive Load 120V
6A
10A
66A
240V
3A
8A
33A
66A 33A
480V
1.5A
5A
16.5A
16.5A
600V
2A
5A
13.2A
13.2A
125V
1.1A
5A
3.7A
-
250V
0.55A
3A
1.8A
-
440V
0.31A
2.5A
1.4A
-
600V
0.2A
1A
0.7A
-
Continuous Current, Ith
16A
Performance Operation cycle
1800 operations/hour Mechanical Durability AC15 duty
Endurance
Electrical Life
AC12 duty DC13, 12 duty
20 M operations 220V
0.5 M operations
440V
0.5 M operations
220V
0.25 M operations
440V
0.25 M operations
24~220V
0.5 M operations
Mini-Contactor Control Relays Description
Part Number
4-Pole AC Coil Relay
CMC-6M/4 (2NO, 2NC)
4-Pole DC Coil Relay
CMD-6M/4 (2NO, 2NC) CA-2M (1NO, 1NC) 6-Pole
CA-2M (2NO) CA-2M (2NC) CA-4M (1NO, 3NC)
Additional Contacts
CA-4M (2NO, 2NC) 8-Pole
CA-4M (3NO, 1NC)
Mini-contactor relays shown with additional contacts configured for multi-pole operation.
CA-4M (4NO) CA-4M (4NC)
25
MIRA Breakers
Low voltage circuit breakers High Breaking Capacity Optimum Coordination Technique Superior Overload Protection Guaranteed Short Circuit Current Ratings Wide Range of Optimized Auxiliaries and Accessories
“I have made a conscious effort to change all my breakers to the MIRA line. The solid protection and high interrupting ratings make Cerus our choice.”
High Performance
Mechanism Unit
High Interrupting Capacity
Optimum cam curve provides consistent contact force during closing and opening of the breaker resulting in excellent current limiting and superior de-bounce for longer contact life.
Arc-extinguishing Unit
Patented puffer assisted self-quenching arc chamber Greatly reduces arc voltage compared to traditional arc quenching technologies for higher interrupting performance.
Up to 65KA on high interrupting models at 480VAC. UL489 Rated IEC Listed
INDUSTRIAL CATALOG
TD/TS Series Circuit Breakers 3-Pole, 40~800 Amp Rated UL 489 Standards
Superior Technology Results in High Performance
Cerus TD and TS circuit breakers provide superior performance in a compact package, with adjustable thermal trip settings and magnetic trip settings for ultimate flexibility Advanced arc quenching technology ensures excellent trip performance and long life Standardized internal accessories are interchangeable on all models and are field or factory installed Accessories mount on right or left side to simplify panel wiring
High Interrupting Capacity Up to 65KA on high interrupting models at 480VAC
Simplified Range Common mounting depths between frames 125A~800A Four frame sizes from 40A~800A
Variety of Trip Units Available FTU - Fixed thermal & magnetic FMU- Adjustable thermal (0.8~1.0), fixed magnetic ATU - Adjustable thermal (0.8~1.0) & magnetic (0.5~1.0)
Variable Accessories
28
Electrical auxiliaries Extended rotary handle Flange handle Locking devices
www.westcoastpower.com 1-866-955-0888
High Interrupting capacity TS800HU TS400HU TS250HU
TD125HU
TS800NU TS400NU
TS250NU
TD125NU
CIRCUIT BREAKERS
Specifications TD125
TS250
TS400
TS800
125
250
400
800
40,50,60,80,100,125
160,200,250
300,400
500,600,800
3
3
3
3
600
600
600
600
Frame size (AF) Rated current (A) No. of Poles Rated operational voltage, Ue AC (V) UL interrupting rating (kA) AC 50/60Hz
NU
HU
NU
HU
NU
HU
NU
HU
240V
50
100
50
100
50
100
50
100
480V
35
65
35
65
35
65
35
65
600V
10
14
10
14
14
20
18
14
Reference standard
UL 489
UL 489
UL 489
UL 489
-
-
-
-
Trip unit (Thermal-Magnetic) • Fixed-thermal, Fixed-magnetic (FTU) • Adjustable-thermal, Fixed-magnetic (FMU
•
-
-
• Adjustable-thermal, Adjustable-magnetic, 3-Pole (ATU)
-
•
•
•
• Molded Case Switch (MCS)
-
-
-
-
Accessories AX
•
•
•
•
AL
•
•
•
•
SHT
•
•
•
•
UVT
•
•
•
•
•
•
•
•
Extended rotary handle
•
•
•
•
Mechanical life (operations)
Flange handle
4,000
5,000
5,000
5,000
Electrical life @ 600V AC (operations)
4,000
1,000
1,000
500
Weight [lbs] Dimensions (W x H x D) [in]
1.2
1.9
5.7
13.6
3.5 x 6.5 x 3.4
4.1 x 7.0 x 3.4
5.5 x 11.5 x 4.3
8.3 x 16.9 x 5.3
TD/TS Series Circuit Breakers Frame Size
125AF
250AF
400AF
800AF
Amp Rating
Thermal Trip Setting
40A
Magnetic Trip Setting
HU Series (High Interrupting)*
NU Series (Normal Interrupting)
32-40A
TD125HU FMU 125 40A
TD125NU FMU 125 40A
50A
40-50A
TD125HU FMU 125 50A
TD125NU FMU 125 50A
60A
48-60A
TD125HU FMU 125 60A
TD125NU FMU 125 60A
80A
64-80A
TD125HU FMU 125 80A
TD125NU FMU 125 80A
10X
100A
80-100A
TD125HU FMU 125 100A
TD125NU FMU 125 100A
125A
100-125A
TD125HU FMU 125 125A
TD125NU FMU 125 125A
160A
125-160A
TS250HU ATU 250 160A
TS250NU ATU 250 160A
200A
160-200A
TS250HU ATU 250 200A
TS250NU ATU 250 200A
250A
200-250A
TS250HU ATU 250 250A
TS250NU ATU 250 250A
300A
250-300A
TS400HU ATU 400 300A
TS400NU ATU 400 300A
400A
300-400A
TS400HU ATU 400 400A
TS400NU ATU 400 400A
500A
400-500A
TS800HU ATU 800 500A
TS800NU ATU 800 500A
600A
500-600A
TS800HU ATU 800 600A
TS800NU ATU 800 600A
800A
600-800A
TS800HU ATU 800 800A
TS800NU ATU 800 800A
5-10X
5-10X
5-10X
29
INDUSTRIAL CATALOG
Optimize Your Circuit Breaker Functionality Alarm Switch (AL) O utput for audio or visual indication of a tripped breaker due to overload, short-circuit, operation of shunt trip, or undervoltage trip conditions, operation of pushbutton. Useful in automated plants where operators must be signaled about changes in the electrical distribution system. Closed contact when the circuit breaker is tripped automatically. Does not function when the breaker is opened manually. Contact is open when the circuit breaker is reset.
Auxiliary Switch (AX) For applications requiring remote “ON” and “OFF” indication Contains two contacts having a common connection; one open, one closed.
Undervoltage Trip (UVT) Simplicity All TD & TS accessories fit all frame sizes of circuit breakers. Cassette style, each accessory fits into a unique slot in each breaker for an easy, trouble free, installation.
Electrical Auxiliaries
30
www.westcoastpower.com 1-866-955-0888
Automatically opens a circuit breaker when the voltage drops to a value ranging between 35% - 75% of the line voltage. The operation is instantaneous - the circuit breaker cannot be reclosed until the voltage returns to 85% of line voltage. Continuously energized, the undervoltage trip must be operating before the circuit breaker can be closed. Range of tripping voltage: 0.35 ~ 0.7Vn MCCB re-closing is possible when voltage: 0.85Vn is exceeded.
Frequency (only AC): 45Hz ~ 65Hz
Shunt Trip (SHT) O pens the mechanism in response to an externally applied voltage signal. Includes coil clearing contacts that automatically clear the signal circuit when the mechanism has tripped, to prevent coil overheating.
CIRCUIT BREAKERS
TD/TS Series Accessories
Alarm & Auxiliary Switches
Alarm Switch
Part Number
Description
AL-TD/TS
Alarm switch for TD/TS series MCCB
AX-TD/TS
Auxiliary switch for TD/TS series MCCB
Auxiliary Switch
Undervoltage Trip, UVT Part Number UVT-24V
Control Voltage
Power Consumption AC (VA)
DC (W)
mA
AC/DC 24V
0.64
0.65
27
UVT-48V
AC/DC 48V
1.09
1.10
23
UVT-120V
AC/DC 110 ~ 130V
0.73
0.75
5.8
UVT-230V
AC/DC 200 ~ 240V/DC 250V
1.21
1.35
5.4
UVT-400V
AC/DC 380 ~ 440V
1.67
-
3.8
UVT-480V
AC/DC 440 ~ 480V
1.68
-
3.5
Maximum opening time (ms)
50
Transformer operating voltage (V) - Drop (Circuit breaker trips) - Rise (Circuit breaker can be switched on)
0.7 ~ 1.35Vn ~0.85Vn
Shunt Trip, SHT Part Number SHT-12VDC
Control Voltage DC 12V
Power Consumption AC (VA)
DC (W)
mA
-
0.36
30
SHT-24V
AC/DC 24V
0.58
0.58
24
SHT-48V
AC/DC 48V
1.22
1.23
25
SHT-120V
AC/DC 110 ~ 130V
1.36
1.37
10.5
SHT-230V
AC/DC 220 ~ 240V/DC250V
1.80
1.88
7.5
SHT-480V
AC/DC 380 ~ 500V
1.15
-
2.3
Maximum opening time (ms)
50
31
INDUSTRIAL CATALOG
Extension Handles Rotary Handles UL Type
12/3R
Circuit breaker with cover frame and rotary extended handle
4X
Degree of Protection Rain, dripping water, dust
Totally protected against ingress of dust and water jets from any direction
Circuit Breaker
Part Number
TD125
EHU-1
TS250
EHU-2
TS400
EHU-3
TS800
EHU-4
TD125
EHU-1X
TS250
EHU-2X
TS400
EHU-3X
TS800
EHU-4X
Circuit Breaker
Part Number
TD125
FH-1
TS250
FH-2
TS400
FH-3
TS800
FH-4
TD125
FH-1X
TS250
FH-2X
TS400
FH-3X
TS800
FH-4X
Flange Handles UL Type
12/3R
4X
Degree of Protection Rain, dripping water, dust
Totally protected against ingress of dust and water jets from any direction
5.
1.
4.
A Full Range of Accessories 1. 2. 3. 4. 5.
32
Circuit Breaker 2. Flange handle Extended rotary handle Locking devices (Removable, Fixed) Mechanical interlock device
www.westcoastpower.com 1-866-955-0888
3.
CIRCUIT BREAKERS
Provide Security and Safety with Cerus Breakers Supports Up to 3 Padlocks
Available for all TD & TS circuit breakers Allows the handle to be locked in the “ON” and “OFF” position Locking in the OFF position guarantees isolation according to IEC 60947-2 Accommodates up to three padlocks with shackle diameters no larger than 5/16” Padlocks are not supplied
Fixed Locking Device MCCB
Function
Part Number
TD125
Lock in “OFF” or “ON” position
PHL1
TS250
Lock in “OFF” or “ON” position
PHL2
TS400
Lock in “OFF” or “ON” position
PHL3
TS800
Lock in “OFF” or “ON” position
PHL4
Guaranteed Breaker Isolation
Removable locking device is available for all TD & TS circuit breakers. The locking device is designed to be easily attached to the circuit-breaker. This device allows the handle to be locked in the “OFF” position. Locking in the “OFF” position guarantees isolation according to IEC 60947-2. A maximum of three (3) padlocks with shackle diameters ranging from 5 to 8mm may be used. Padlocks are not supplied
Removable Locking Device MCCB
Function
Part Number
TD125
“OFF” position
PL1
TS250
“OFF” position
PL2
TS400
“OFF” position
PL3
TS800
“OFF” position
PL4
Circuit Breaker Interlocks
Mechanical interlock is applied to the front of two breakers mounted side-by-side Prevents simultaneous closing of the two breakers Mounts directly on the cover of the breakers Interlocking plate allows user to lock both breakers in the OFF position or only one breaker in the OFF position A simple and effective interlock for bypass or other power transfer systems
Mechanical Interlock Frame Size
Part Number
TD125
MIT13
TS250
MIT23
TS400
MIT33
TS800
MIT43
33
Exceeding the Industrial Standard Optimize System Reliability Fast Installation Higher Reliability
“Cerus makes sure that I get the right starter for my application. They deliver when I need it and comes ready to install. Talk about service.”
From 1/2 HP to 300HP, Cerus has your starter application covered. You get time and money saving features on top of Cerus’ legendary quality and service – all backed by a 5-year contactor warranty! We don’t meet the specs – we set them! Economy Starters
MMS: Enclosed Manual Motor Starters
ISS: Industrial Start/Stop
IPS: Industrial & Pump Starter
Ranges HP ranges* Amperage ranges Starter Type
3
/4 HP - 50HP
3
/4 HP - 20HP
1HP - 300HP
1HP - 300HP
0.1A - 85A
0.1A - 32A
0.1A - 400A
0.1A - 400A
Non-reversing
Non-reversing
Non-reversing (standard), or Combination
Non-reversing (standard) or Combination
Protective Options
Bi-metallic Thermal Overload (Class 10)
Bi-metallic Thermal Overload (Class 10)
Construction
UL Type 1
UL Type 4X
Operator Options
On/Off pushbuttons available
Automation System Interface
-
* Horsepower minimum & maximum ratings are based on 460V applications
-
-
Electronic Overload (9~95A Models) Bi-metallic Thermal Overload (Class 10) (100~400A Models)
Electronic Overload Phase Fail Protection Stall Protection Locked Rotor Over/Under Voltage Power Fail Options Anti-Cycling
UL Type 1, 4, 12, 4X
UL Type 1, 4, 12, 4X
START/STOP pushbuttons
HOA/Reset Keypad Optional START/STOP pushbuttons
Remote Operator Station
Remote Operator Station Dry/Voltage Auto Input Permissive Auto Override (Fireman’s) 120VAC Control Power Transformer Damper Control & Status
INDUSTRIAL CATALOG
Enclosed Manual Motor Starter
1Ø & 3Ø, 115~600VAC, 1/10~30HP High Break Thermal Magnetic or Magnetic Trip Only Lockable Disconnect
Rugged Construction with Standard Handle Lock-out With a heavy-duty impact-resistant plastic case. IP65 rating. (UL Type 4/4X pending) Standard rotary switch includes easy provision for padlock/tag-out at no extra charge.
Superior Protection
UL listed manual motor control provides motor overload and motor circuit protection in one package - no separate circuit breaker or fuses required Both models are rated up to 100,000 Amps interrupting capacity - ensuring maximum compatibility and coordination with existing electrical installations. Meet UL Type E ratings for group motor installation with no additional branch circuit breaker or fuses required
Enclosed Manual Motor Starter Horsepower Thermal Magnetic Rated Release Release Single Phase Three Phase Operational Adjustment Operating Current (A) Range (A) Current (A) 115V 230V 230V 460V 575V 1.6
1-1.6
20.8
-
1/10
-
3/4
3/4
2.5
1.6-2.5
32.5
-
1/6
1/2
1
1/
4
2.5-4
52
1/8
1/3
3/4
2
3
6
4-6
78
1/4
1/2
11/2
3
5
8
5-8
104
1/3
1
2
5
5
10
6-10
130
1/2
11/2
3
5
71/2
13
9-13
169
1/2
2
3
71/2
10
17
11-17
221
1
3
5
10
15
22
14-22
286
1 2
1/
3
1 2
7/
15
20
26
18-26
338
2
3
71/2
15
20
32
22-32
416
2
5
10
20
30
*UL rating for manual motor controller-group ratings. Manual motor starter group ratings may vary – visit www.westcoast-
36
1 2
www.westcoastpower.com 1-866-955-0888
SCIC (kA) 240V kA
480V kA
600V kA
100 100 100 100 100 100 100 100 100 100 100
65 65 65 65 65 65 65 30 30 30 30
25 25 25 25 25 25 25 10 10 10 10
High Break Trip
Magnetic Trip Only
CIE-MMS-32H-1.6
CIE-MMS-32HI-1.6
CIE-MMS-32H-2.5
CIE-MMS-32HI-2.5
CIE-MMS-32H-4
CIE-MMS-32HI-4
CIE-MMS-32H-6
CIE-MMS-32HI-6
CIE-MMS-32H-8
CIE-MMS-32HI-8
CIE-MMS-32H-10
CIE-MMS-32HI-10
CIE-MMS-32H-13
CIE-MMS-32HI-13
CIE-MMS-32H-17
CIE-MMS-32HI-17
CIE-MMS-32H-22
CIE-MMS-32HI-22
CIE-MMS-32H-26
CIE-MMS-32HI-26
CIE-MMS-32H-32
CIE-MMS-32HI-32
ENCLOSED INDUSTRIAL STARTERS
High Value Enclosed Starter 1Ø & 3Ø, 115~600VAC, 1/10~60HP Available Start/Stop Pushbutton Option Thermal Motor Overload
Cost Effective and Reliable Start/Stop pushbutton options Metal or plastic enclosures High reliability up to 2.5 million electrical contactor cycles at full rated current* (varies by model)
Thermal overload protection Differential phase failure protection Ambient compensated (-5º to 40ºC)
Magnetic Starters - NEMA1 Plastic Enclosure with Thermal Overload & Start/Stop Pushbuttons Single Phase
Three Phase
–
1/10
-
-
3/4
3/4
Maximum Overload (A)
Part Number
115V 230V 200V 230V 460V 575V* CMW-9MB/K-
CMW-12MB/K-
CMW-18MB/K-
CMW-22MB/K-
1.6
–
1/8
1/2
1/2
1
1
CMW-9MB/K-
CMW-12MB/K-
CMW-18MB/K-
CMW-22MB/K-
2.5
1/8
1/3
3/4
3/4
2
2
CMW-9MB/K-
CMW-12MB/K-
CMW-18MB/K-
CMW-22MB/K-
4
1/4
1/2
1
1.5
3
3
CMW-9MB/K-
CMW-12MB/K-
CMW-18MB/K-
CMW-22MB/K-
6
1/3
1
2
2
5
5
CMW-9MB/K-
CMW-12MB/K-
CMW-18MB/K-
CMW-22MB/K-
9
1/2
1.5
2
3
5
5
CMW-9MB/K-
CMW-12MB/K-
CMW-18MB/K-
CMW-22MB/K-
10
1/2
2
3
3
7.5
7.5
CMW-9MB/K-
CMW-12MB/K-
CMW-18MB/K-
CMW-22MB/K-
13
1
3
3
5
10
10
CMW-9MB/K-
CMW-12MB/K-
CMW-18MB/K-
CMW-22MB/K-
18
1 .5
3
5
7.5
15
15
CMW-9MB/K-
CMW-12MB/K-
CMW-18MB/K-
CMW-22MB/K-
22
Magnetic Starters - NEMA1 Steel Enclosure with Thermal Overload
–
1/10
-
-
3/4
3/4
CMW-9
CMW-12
CMW-22
B/K
/K
Maximum Overload Amps 1.6
–
1/8
1/2
1/2
1
1
CMW-9
CMW-12
CMW-22
B/K
/K
2.5
1/8
1/3
3/4
3/4
2
2
CMW-9
CMW-12
CMW-22
B/K
/K
4
1/4
1/2
1
1.5
3
3
CMW-9
CMW-12
CMW-22
CMW-40
B/K
/K
6
1/3
1
2
2
5
5
CMW-9
CMW-12
CMW-22
CMW-40
B/K
/K
9
1/2
1.5
2
3
5
5
CMW-12
CMW-22
CMW-40
B/K
/K
10
1/2
2
3
3
7.5
7.5
CMW-12
CMW-22
CMW-40
B/K
/K
13
1
3
3
5
10
10
CMW-12
CMW-22
CMW-40
B/K
/K
18
Single Phase 115V
230V
Three Phase 200V
Part Number
230V 460V 575V*
Start/ Stop
Base
1 .5
3
5
7.5
15
15
CMW-22
CMW-40
CMW-50
CMW-85
B/K
/K
22
2
3
7.5
7.5
15
20
CMW-22
CMW-40
CMW-50
CMW-85
B/K
/K
26
3
5
7.5
10
20
25
CMW-40
CMW-50
CMW-85
B/K
/K
36
3
5
10
10
25
25
CMW-40
CMW-50
CMW-85
B/K
/K
40
3
7.5
10
10
30
30
CMW-50
CMW-85
B/K
/K
50
3
7.5
15
15
30
40
CMW-50
CMW-85
B/K
/K
65
5
10
20
20
40
50
CMW-85
B/K
/K
75
7.5
15
20
25
50
60
CMW-85
B/K
/K
85
*Visit www.westcoastpower.com for warranty terms. Contactor ratings vary by model.
37
INDUSTRIAL CATALOG
ISS
Industrial Start/Stop
1Ø & 3Ø, 115~600VAC, 1–300HP Start/Stop Pushbuttons Superior Electronic Motor Protection
NEMA Sized
Proven Reliability for Demanding Industrial Applications Everything You Need is Standard
Start/Stop pushbutton control with terminals for remote 3-wire operator station Multi-tap control power transformer accepts all common motor voltages Solid-state electronic overload relay (Up to NEMA Size 3) Lockable cover prevents tampering
Quality Construction UL 508A Listed NEMA size rated contactors 5-Year warranty
Superior Motor Overload Protection
Phase loss and phase imbalance protection Ambient compensated (-5º to 40ºC) Manual Reset Trip-free design
Wide range electronic overload eliminates sizing call backs.
Combination Versions Include Disconnect
Motor Circuit Protector disconnect provides branch and short circuit protection High interrupting ratings for maximum electrical system compatibility No fuses or breakers required - save time and money Lockable through the door handle for safety
Easy Installation with Fewer Call Backs
38
F lexible sizing makes ordering easy UL Type 1 enclosure includes top and bottom knock-outs Mount more starters in less space with our slim line case High reliability...up to 2.5 million contactor electrical cycles at full rated current
www.westcoastpower.com 1-866-955-0888
Our lockable disconnect provides superior protection without costly fuses.
ENCLOSED INDUSTRIAL STARTERS
Specifications Starter Type Industrial Starter Standard or Combination UL Type 1, UL Type 4/12, UL Type 4X (Stainless or Fiberglass) User Interface Start / Stop Pushbuttons Standard Control Operations 3-Wire
Terminal block provision for remote Start/Stop
Protective Functions (9~95A Models) Overload Type Electronic; I2t Thermal Trip Curve
Simple and clearly indicated Start/Stop operation.
Trip Class Class 1-30 Reset Manual Phase Unbalanced Trip within 3 seconds @ 70% unbalance Phase Loss Trip within 3 seconds Stall Trip within 3 seconds @ 170% FLA Protective Functions (100~400A Models) Overload Type Thermal bi-metallic Trip Class Class 10 (100~800A) Reset Manual Phase Loss Differential overload protection
Provided terminal blocks allow for connection to remote Start/Stop station.
Mechanical Enclosure types
UL Type 1 or UL Type 4/12
Environmental Ambient Operating Temp -5° to 140° F (-20° to 60° C) Ambient Storage Temp -5° to 185° F (-20° to 85° C) Relative Humidity 5% to 95% non-condensing
Compact & Rugged UL Type 1 Model R eady for indoor installations with conduit knockouts and mounting flanges Same-day shipping available up to NEMA Size 1
39
INDUSTRIAL CATALOG
ISS Ordering and Sizing Information
Standard Start/Stop pushbuttons Enclosure types for all environments Provision for remote operator station Combination version features motor circuit protector to provide branch and short circuit protection
Options Part Number
Description
ISS-RST
Front Mounted Reset Pushbutton
ISS-TBC
Terminal Control Only
ISS-1PH
Wiring for Single Phase Motor
Standard Magnetic Starters 9~95A - Electronic Overload Horsepower Single Phase
Three Phase
115V 230V 200V 230V 460V 575V*
SCIC KAIC NEMA @460V Size
UL Type 1
UL Type 4/12
UL Type 4X Fiberglass
UL Type 4X Stainless
1/6
1/2
1
1.5
3
3
5
00
ISS1-9/J-5
ISS12-9/J-5
ISSXF-9/J-5
ISSXS-9/J-5
1
3
5
5
10
15
5
0
ISS1-18/J-22
ISS12-18/J-22
ISSXF-18/J-22
ISSXS-18/J-22
2
5
7.5
10
20
25
5
1
ISS1-32/J-40
ISS12-32/J-40
ISSXF-32/J-40
ISSXS-32/J-40
3
10
20
20
40
50
5
2
ISS1-50/J-80
ISS12-50/J-80
ISSXF-50/J-80
ISSXS-50/J-80
5
15
30
40
60
60
10
3
-
ISS12-85/J-80
ISSXF-85/J-80
ISSXS-85/J-80
UL Type 4/12
UL Type 4X Fiberglass
UL Type 4X Stainless
Combination Magnetic Starters 9~95A - Electronic Overload Horsepower Single Phase
Three Phase
115V 230V 200V 230V 460V 575V*
40
*SCIC NEMA KAIC @460V Size
UL Type 1
-
1/10
-
-
3/4
3/4
65
00
ISS1-9/ J-G1.6-5
ISS12-9/J-G1.6-5
ISSXF-9/J-G1.6-5
ISSXS-9/J-G1.6-5
-
1/6
1/2
1/2
1
1.5
65
00
ISS1-9/J-G2.5-5
ISS12-9/J-G2.5-5
ISSXF-9/J-G2.5-5
ISSXS-9/J-G2.5-5
1/8
1/3
3/4
3/4
2
3
65
00
ISS1-9/J-G4-5
ISS12-9/J-G4-5
ISSXF-9/J-G4-5
ISSXS-9/J-G4-5
1/6
1/2
1
1.5
3
3
65
00
ISS1-9/J-G6-5
ISS12-9/J-G6-5
ISSXF-9/J-6-5
ISSXS-9/J-6-5
1/3
1
2
2
5
5
65
0
ISS1-18/J-G8-22
ISS12-18/J-G8-22
ISSXF-18/J-G8-22
ISSXS-18/J-G8-22
1/2
1.5
2
3
5
7.5
65
0
ISS1-18/J-G10-22
ISS12-18/J-G10-22
ISSXF-18/J-G10-22
ISSXS-18/J-G10-22 ISSXS-18/J-G13-22
1/2
2
3
3
7.5
10
65
0
ISS1-18/J-G13-22
ISS12-18/J-G13-22
ISSXF-18/J-G13-22
1
3
3
5
10
15
30
0
ISS1-18/J-G17-22
ISS12-18/J-G17-22
ISSXF-18/J-G17-22
ISSXS-18/J-G17-22
1.5
3
5
7.5
15
20
30
1
ISS1-32/J-G22-40
ISS12-32/J-G22-40
ISSXF-32/J-G22-40
ISSXS-32/J-G22-40
2
3
7.5
7.5
15
20
30
1
ISS1-32/J-G26-40
ISS12-32/J-G26-40
ISSXF-32/J-G26-40
ISSXS-32/J-G26-40
ISS1-32/J-G32-40
2
5
7.5
10
20
25
30
1
ISS12-32/J-G32-40
ISSXF-32/J-G32-40
ISSXS-32/J-G32-40
3
7.5
10
10
30
30
50
2
-
ISS12-50/J-G40-40
ISSXF-50/J-G40-40
ISSXS-50/J-G40-40
3
10
15
15
40
40
50
2
-
ISS12-50/J-G50-80
ISSXF-50/J-G50-80
ISSXS-50/J-G50-80
5
10
20
20
50
50
50
3
-
ISS12-85/J-G63-80
ISSXF-85/J-G63-80
ISSXS-85/J-G63-80
5
15
20
25
60
60
50
3
-
ISS12-85/J-G75-80
ISSXF-85/J-G75-80
ISSXS-85/J-G75-80
www.westcoastpower.com 1-866-955-0888
ENCLOSED INDUSTRIAL STARTERS
Standard Start/Stop pushbuttons Enclosure types for all environments Provision for remote operator station Combination version features molded case circuit breaker to provide branch and short circuit protection
Standard Magnetic Starters 100~400A - Thermal Overload Horsepower Three Phase 200V 230V 460V 575V*
SCIC KAIC NEMA @460V Size
UL Type 4/12
UL Type 4X Fiberglass
UL Type 4X Stainless
40
40
75
75
10
-
ISS12-125/K-125
ISSXF-125/K-125
ISSXS-125/K-125
40
50
100
100
10
4
ISS12-150/K-150
ISSXF-150/K-150
ISSXS-150/K-150
60
75
150
150
10
-
ISS12-220/K-220
ISSXF-220/K-220
ISSXS-220/K-220
100
100
200
200
18
5
ISS12-300/K-300
ISSXF-300/K-300
ISSXS-300/K-300
125
150
300
300
18
-
ISS12-400/K-400
ISSXF-400/K-400
ISSXS-400/K-400
Combination Magnetic Starters 100~400A -Thermal Overload Horsepower Three Phase 200V 230V 460V 575V*
SCIC KAIC NEMA @460V Size
UL Type 4/12
UL Type 4X Fiberglass
UL Type 4X Stainless
40
40
75
75
10
-
ISS12-125/K-G-125
ISSXF-125/K-G-125
ISSXS-125/K-G-125
40
50
100
100
10
4
ISS12-150/K-G-150
ISSXF-150/K-G-150
ISSXS-150/K-G-150
60
75
150
150
10
-
ISS12-220/K-G-220
ISSXF-220/K-G-220
ISSXS-220/K-G-220
100
100
200
200
18
5
ISS12-300/K-G-300
ISSXF-300/K-G-300
ISSXS-300/K-G-300
125
150
300
300
18
-
ISS12-400/K-G-400
ISSXF-400/K-G-400
ISSXS-400/K-G-400
* For 600V part numbers please consult factory. ++ For starters over NEMA Size 3 consult factory.
41
INDUSTRIAL CATALOG
Industrial Starters
1Ø & 3Ø, 115~600VAC, 1–200HP Wye-Delta & Reversing Models Optional Control Features
NEMA Sized
Enclosed Wye-Delta Starters
Standard timer ensures smooth transition between start & run operations Each starter includes a control power transformer and Hand/Off/Auto switch Ambient temperature compensated differential bi-metallic thermal overload protection Terminal block connection for remote operation Optional molded case circuit breaker disconnect provides branch and short circuit protection Disconnect features high interrupting ratings for maximum electrical system compatibility 5-Year contactor warranty
Enclosed Wye-Delta, Open Transition Horsepower
UL Type 4/12 Standard
230V
460V
20
20
40
CIE12-50/DW
CIE12-50/DW-G
40
40
60
CIE12-85/DW
CIE12-85/DW-G
50
50
125
CIE12-125/DW
CIE12-125/DW-G
60
60
125
CIE12-150/DW
CIE12-150/DW-G
125
125
200
CIE12-220/DW
CIE12-220/DW-G
150
150
300
CIE12-300/DW
CIE12-300/DW-G
200
200
400
CIE12-400/DW
CIE12-400/DW-G
Options Part Number
42
UL Type 4/12 Combination
208V
Description
STR-RPL
Run pilot light (Red Standard)
STR-RST
Door mounted Reset pushbutton
STR-OFF
Off pilot light (Green Standard)
STR-STP
Emergency stop pushbutton (40mm, push-pull)
STR-1PH
Wiring for Single Phase Motor
www.westcoastpower.com 1-866-955-0888
ENCLOSED INDUSTRIAL STARTERS
Enclosed Reversing Starters
Each starter includes a control power transformer and terminal block connections Easily integrate remote user controls such as pendant stations or switch/pushbutton operators Solid-state electronic overload relay provides phase loss and stall protection Optional motor circuit protector (MCP) disconnect provides branch and short circuit protection Disconnect features high interrupting ratings for maximum electrical system compatibility Options for user selected local control methods 5-Year contactor warranty
Industrial Reversing Starters 9~95A - Electronic Overload Horsepower Single Phase
Three Phase
115V 230V 200V 230V 460V 575V*
SCIC KAIC NEMA @460V Size
UL Type 4/12
UL Type 4X Fiberglass
UL Type 4X Stainless
1/6
1/2
1
1.5
3
3
5
00
CIE12-9/R-5
CIEXF-9/R-5
CIEXS-9/R-5
1
3
5
5
10
15
5
0
CIE12-18/R-22
CIEXF-18/R-22
CIEXS-18/R-22
2
5
7.5
10
20
25
5
1
CIE12-32/R-40
CIEXF-32/R-40
CIEXS-32/R-40
3
10
20
20
40
50
5
2
CIE12-50/R-80
CIEXF-50/R-80
CIEXS-50/R-80
5
15
30
40
60
60
10
3
CIE12-85/R-80
CIEXF-85/R-80
CIEXS-85/R-80
Industrial Combination Reversing Starters 9~95A - Electronic Overload Horsepower Single Phase
Three Phase
115V 230V 200V 230V 460V 575V*
SCIC KAIC NEMA @460V Size
UL Type 4/12
UL Type 4X Fiberglass
UL Type 4X Stainless
-
1/10
-
-
3/4
3/4
65
00
CIE12-9/R-G1.6-5
CIEXF-9/R-G1.6-5
CIEXS-9/R-G1.6-5
-
1/6
1/2
1/2
1
1.5
65
00
CIE12-9/R-G2.5-5
CIEXF-9/R-G2.5-5
CIEXS-9/R-G2.5-5
1/8
1/3
3/4
3/4
2
3
65
00
CIE12-9/R-G4-5
CIEXF-9/R-G4-5
CIEXS-9/R-G4-5
1/6
1/2
1
1.5
3
3
65
00
CIE12-9/R-G6-5
CIEXF-9/R-G6-5
CIEXS-9/R-G6-5
1/3
1
2
2
5
5
65
0
CIE12-18/R-G8-22
CIEXF-18/R-G8-22
CIEXS-18/R-G8-22
1/2
1.5
2
3
5
7.5
65
0
CIE12-18/R-G10-22
CIEXF-18/R-G10-22
CIEXS-18/R-G10-22
1/2
2
3
3
7.5
10
65
0
CIE12-18/R-G13-22
CIEXF-18/R-G13-22
CIEXS-18/R-G13-22
1
3
3
5
10
15
30
0
CIE12-18/R-G17-22
CIEXF-18/R-G17-22
CIEXS-18/R-G17-22
1.5
3
5
7.5
15
20
30
1
CIE12-32/R-G22-40
CIEXF-32/R-G22-40
CIEXS-32/R-G22-40
2
3
7.5
7.5
15
20
30
1
CIE12-32/R-G26-40
CIEXF-32/R-G26-40
CIEXS-32/R-G26-40
2
5
7.5
10
20
25
30
1
CIE12-32/R-G32-40
CIEXF-32/R-G32-40
CIEXS-32/R-G32-40
3
7.5
10
10
30
30
50
2
CIE12-50/R-G40-40
CIEXF-50/R-G40-40
CIEXS-50/R-G40-40
3
10
15
15
40
40
50
2
CIE12-50/R-G50-80
CIEXF-50/R-G50-80
CIEXS-50/R-G50-80
5
10
20
20
50
50
50
3
CIE12-85/R-G63-80
CIEXF-85/R-G63-80
CIEXS-85/R-G63-80
5
15
20
25
60
60
50
3
CIE12-85/R-G75-80
CIEXF-85/R-G75-80
CIEXS-85/R-G75-80
* For 600V part numbers please consult factory. ++ For starters over NEMA Size 3 consult factory.
Options Part Number
Description
STR-RPL
Run pilot light (Red Standard)
STR-RST
Door mounted Reset pushbutton
STR-OFF
Off pilot light (Green Standard)
STR-STP
Emergency stop pushbutton (40mm, push-pull)
STR-1PH
Wiring for Single Phase Motor
43
INDUSTRIAL CATALOG
IPS
Industrial & Pump Starter 1Ø & 3Ø, 115~600VAC, 1–200HP Start/Stop Pushbuttons or HOA Superior Motor & Pump Protection
NEMA Sized
Internal HOA Keypad with LCD Display Door mounted pilot devices Plain English operation – easy to set up and simple to operate LEDs indicate Hand/Off/Auto modes, run and fault conditions
Built-in Pump Protection Features Standard over/undervoltage detection with selectable trip settings Optional true power measurement detects dry pump and provides alarm output; preventing dry pump operation to protect motor and pump from potential damage
Power Metering (option)
Digital display clearly delivers instantaneous & precise motor parameter data and fault conditions.
1% ANSI grade metering with pulse/analog output for accurate measurements kW and kWh data available on LCD display
Voltage & Dry Contact Inputs for PLC Compatibility Wire directly from a centralized controller to the starter, no interposing relays necessary Save on installation costs and increase reliability.
Dual Shut Down Inputs Manual shut down or automatic high-limit alarm shut down Accepts either a voltage signal or contact opening
Actuator Control Interlocks valves with starter ensuring proper sequence of operation Reduces wiring and saves on installation costs
44
www.westcoastpower.com 1-866-955-0888
The IPS includes a rugged Hand/Off/Auto switch.
PUMP CONTROLS
Wide Range Class 1-60 Electronic Overload Prevents ordering confusion and eliminates call backs due to mis-sized heaters. Advanced protective features including anti-cycling, manual/auto reset, phase sequence, phase loss, stall and locked rotor protection
Flexible Control Transformer (CPT) Multi-tap CPT input accepts all common motor voltages Integrated secondary protection – no fuses required
Our integrated CTs provide superior motor protection and metering accuracy.
Combination Versions Include Disconnect
Motor circuit protection disconnect provides branch and short circuit protection High interrupting ratings for maximum electrical system compatibility No fuses required – save time and money Lockable handle for safety Our lockable disconnect provides superior protection without costly fuses.
Options Simplex Pump Options Inputs for float control (5 float inputs maximum) Dry pump protection
Power Metering
1% ANSI Accuracy with integrated current transformers Pulse kWh output, N.O. Contact, max on resistance 8 ohms, max 45V 4- 20 mA kW output Includes kW, kWh display
Ground Fault Protection
Over/Under Voltage
Protects motors from damage due to ground current conditions UL 1053 Certified
Protects motors from damage Adjustable minimum and maximum voltage thresholds
24V Actuator Control
Time Delay
Option in lieu of 120VAC standard
Programmable On/Off delay
45
INDUSTRIAL CATALOG
Specifications Starter Type Industrial & Pump Starter Standard or Combination UL Type 4/12 Enclosure User Interface Internal Display
Digital keypad with LEDs
LED pilot lights
Hand, Off, Auto, Run, Fault
LCD parameter display
16 character, dual line, backlight
22mm Pilot Devices
HOA, Start/Stop Pushbuttons, Reset
Standard Control Operations Inputs Voltage Auto Run
Apply 10 - 130VAC/DC to energize
Emergency Power Off
Apply 10 - 130VAC/DC to energize
Actuator position switch
N.O. dry contact closure
Permissive Auto
N.O. dry contact closure
Shutdown
N.C. dry contact input
Outputs Proof of flow status relay (adjustable)
N.O., 0.3A@125VAC; 1A@24VAC
Fault relay
N.O., 0.3A@125VAC; 1A@24VAC
Actuator motor control
120VAC, 0.2A max (24VAC optional)
Power fail mode
Restart last mode, no delay (default)
Operational
Restart with delay Restart Off - LED flashes last mode On/Off Time Delay
Programmable, selectable from 0.1 to 99 seconds
Protective Functions Overload Type Current Setting Range
Mechanical Electronic; I t Thermal Trip Curve 2
Enclosure Types
UL Type 1 or UL Type 4/12
0.5 - 95A
Trip Class Class 5 - 60 Reset Phase Unbalance Phase Loss Stall/Locked Rotor* Cycle Fault*
Manual or Automatic Trip within 1 second at programmed unbalance percentage (75% default) Trip within 1 second (50% default) Trip within 0.5 seconds @ 300% FLA Trip if cycle rate exceeds 1200 starts per hour
Under Power Trip*
Trip within 10 seconds @ 50% measured horsepower
Phase Sequence*
Trip within 0.1 seconds upon reverse phase detection
Warm Start Provision
Delays motor restart if calculated motor temperature exceeds thermal curve
Ground Fault Over/Under Voltage
UL1053 Certified (Optional) Selectable trip within 0.1-99 seconds (Optional)
*Programmable On or Off. See owner’s manual for customer selectable settings.
46
www.westcoastpower.com 1-866-955-0888
Environmental Ambient Operating Temp
-5° to 140° F (-20° to 60° C)
Ambient Storage Temp
-5° to 185° F (-20° to 85° C)
Relative Humidity
5% to 95% non-condensing
PUMP CONTROLS
IPS
Options
Ordering and Sizing Information
Part Number
UL Type 4/12 for outdoor use Fully sealed: welded and gasketed for long life Rugged 16 gauge steel construction Combination version features motor circuit protector to provide branch and short circuit protection.
Description
IPS-HOA
Hand/Off/Auto Control (Door Mounted)
IPS-STSP
Start/Stop Pushbutton Control (Door Mounted)
IPS-PMP
Pump Option Card (with Dry Pump Protection)
IPS-PWR
Power Monitoring with Pulse/Analog output
IPS-DRY
Dry Pump Protection
IPS-GFLT
Ground Fault Protection
IPS-TMR
Programmable On/Off Delay Timer
IPS-24
24V Actuator Control
UL Type 4/12 Outdoor Enclosure
Standard Industrial Pump Starter - Electronic Overload Horsepower Single Phase
Three Phase
SCIC KAIC @460V
NEMA Size
Part Number
115V
230V
200V
230V
460V
575V*
–
1/2
2
3
5
7.5
5
00
IPS12-9/J-9 IPS12-18/J-18
1
3
5
7.5
10
15
5
0
2
5
7.5
10
20
25
5
1
IPS12-32/J-32
3
10
20
25
40
50
5
2
IPS12-50/J-50
5
15
30
40
60
75
10
3
IPS12-85/J-85
UL Type 4/12 Outdoor Enclosure
Combination Industrial Pump Starter - Electronic Overload Horsepower Single Phase
Three Phase
115V
230V
200V
–
1/10
–
1/6
1/8
1/3
3/4
1/4
1/2
1
1/3
1
1/2 1/2 1
SCIC KAIC @460V
NEMA Size
Part Number
230V
460V
575V*
–
–
3/4
3/4
65
00
IPS12-9/J-G1.6-9
1/2
1/2
1
1.5
65
00
IPS12-9/J-G2.5-9
3/4
2
3
65
00
IPS12-9/J-G4-9
1.5
3
5
65
00
IPS12-9/J-G6-9
2
2
5
5
65
0
IPS12-18/J-G8-18
1.5
2
3
5
7.5
65
0
IPS12-18/J-G10-18
2
3
3
7.5
10
65
0
IPS12-18/J-G13-18
3
3
5
10
15
30
0
IPS12-18/J-G17-18 IPS12-32/J-G22-32
1.5
3
5
7.5
15
20
30
1
2
3
7.5
7.5
15
20
30
1
IPS12-32/J-G26-32
2
5
7.5
10
20
25
30
1
IPS12-32/J-G32-32
3
7.5
10
10
30
30
50
2
IPS12-50/J-G40-50
3
10
15
15
30
40
50
2
IPS12-50/J-G50-50
5
10
20
20
40
60
50
3
IPS12-85/J-G63-85
5
15
20
25
50
60
50
3
IPS12-85/J-G75-85
* For 600V part numbers please consult factory. ++ For starters over NEMA Size 3 consult factory.
47
INDUSTRIAL CATALOG
SPS
Standard Pump Starter 1Ø & 3Ø, 115~600VAC, 1–300HP HOA Switch with LED Run Pilot Light Electronic Motor Protection
NEMA Sized
Economical and Functional Pump Starter Control Heavy Duty HOA Switch with Run Pilot Light Simple and functional basic control Long life LED pilot light
Wide Range Class 1-30 Electronic Overload Prevents ordering confusion and eliminates call backs due to mis-sized heaters Advanced protective features including phase loss, phase imbalance, stall protection & manual reset
Rugged HOA switch
Flexible Control Transformer (CPT) Multi-tap CPT input accepts all common motor voltages Integrated secondary protection – no fuses required Standard 120VAC secondary control
Specifications Starter Type Standard Pump Starter
Our lockable disconnect provides superior protection without costly fuses.
Standard or Combination UL Type 1 or UL Type 4/12 Enclosure User Interface HOA Selector switch with Run pilot light Standard Control Operations Inputs
Protective Functions Dry Auto Run
N.O. dry contact closure to energize starter
Mechanical Enclosure types
Current Setting Range 0.3 - 1.5A, 1 - 5A, 4.4 - 22A, 8 - 40A, 16 - 80A UL Type 1 or UL Type 4/12
Environmental Ambient Operating Temp -5° to 140° F (-20° to 60° C) Ambient Storage Temp -5° to 185° F (-20° to 85° C) Relative Humidity 5% to 95% non-condensing
48
Overload Type Electronic; I2t Thermal Trip Curve
www.westcoastpower.com 1-866-955-0888
Trip Class Class 1-30 Reset Manual Phase Unbalanced Trip within 3 seconds @ 70% unbalance Phase Loss Trip within 3 seconds Stall Condition Trip within 3 seconds @ 170% FLA
PUMP CONTROLS
Combination Versions Include Disconnect
Motor circuit protection disconnect provides branch and short circuit protection High interrupting ratings for maximum electrical system compatibility No fuses required – save time and money Lockable handle for safety
SPS Ordering and Sizing Information Options Part Number
Description
SPS-RST
Front Mounted Reset Pushbutton
SPS-TBC
Terminal Control Only
SPS-1PH
Wiring for Single Phase Motor
Standard Pump Starters - HOA Electronic Overload Horsepower SCIC KAIC NEMA Single Phase Three Phase Size 115V 230V 200V 230V 460V 575V* @460V
UL Type 1
UL Type 4
1/2
1
1.5
3
3
5
00
SPS1-9/J-5
SPS4-9/J-5
1
3
5
5
10
15
5
0
SPS1-18/J-22
SPS4-18/J-22
1.5
3
5
7.5
15
20
5
1
SPS1-32/J-22
SPS4-32/J-22
2
5
7.5
10
20
25
5
1
SPS1-32/J-40
SPS4-32/J-40
3
7.5
10
10
25
30
5
2
SPS1-50/J-40
SPS4-50/J-40
3
10
20
20
40
50
5
2
SPS1-50/J-80
SPS4-50/J-80
5
15
30
40
60
60
10
3
SPS1-85/J-80
SPS4-85/J-80
UL Type 1
UL Type 4
Combination Pump Starters - HOA Electronic Overload Horsepower SCIC NEMA Single Phase Three Phase KAIC Size 115V 230V 200V 230V 460V 575V* @460V 1/10
–
–
3/4
3/4
65
00
SPS1-9/J-G1.6-5
SPS4-9/J-G1.6-5
1/6
1/2
1/2
1
1.5
65
00
SPS1-9/J-G2.5-5
SPS4-9/J-G2.5-5
1/8
1/3
3/4
3/4
2
3
65
00
SPS1-9/J-G4-5
SPS4-9/J-G4-5
1/4
1/2
1
1.5
3
3
65
00
SPS1-9/J-G6-5
SPS4-9/J-G6-5
1/3
1
2
2
5
5
65
0
SPS1-18/J-G8-22
SPS4-18/J-G8-22
1/2
1.5
2
3
5
7.5
65
0
SPS1-18/J-G10-22
SPS4-18/J-G10-22
1/2
2
3
3
7.5
10
65
0
SPS1-18/J-G13-22
SPS4-18/J-G13-22
1
3
3
5
10
15
30
0
SPS1-18/J-G17-22
SPS4-18/J-G17-22
1.5
3
5
7.5
15
20
30
1
SPS1-32/J-G22-40
SPS4-32/J-G22-40
2
3
7.5
7.5
15
20
30
1
SPS1-32/J-G26-40
SPS4-32/J-G26-40
2
5
7.5
10
20
25
30
1
SPS1-32/J-G32-40
SPS4-32/J-G32-40
3
7.5
10
10
30
30
50
2
SPS1-50/J-G40-40
SPS4-50/J-G40-40
3
10
15
15
30
40
50
2
SPS1-50/J-G50-80
SPS4-50/J-G50-80
5
10
20
20
40
50
50
3
SPS1-85/J-G63-80
SPS4-85/J-G63-80
5
15
20
25
50
60
50
3
SPS1-85/J-G75-80
SPS4-85/J-G75-80
* For 600V part numbers please consult factory. ++ For starters over NEMA Size 3 consult factory.
49
INDUSTRIAL CATALOG
Duplex Alternating Pump Starter 1Ø & 3Ø, 115~600VAC, 1–200HP Start/Stop Pushbuttons or HOA UL Type 4 Enclosure
NEMA Sized
A Simple & Reliable Solution Designed for Dual Pump Control The Cerus Basic Duplex pump starter provides alternating control between two motors. A single HOA switch allows manual operation or the starter accepts a remote run command input. Each starter includes a motor selector switch to alternate between motors. Additional alternating options include an alternating relay, 24-hour timer or 7-day clock allowing maximum control flexibility.
Dependable Alternating Control
Single HOA selector switch with Run pilot lights for each pump Automatically alternates motors in the event of a fault or trip Manual alternating controlled via selector switch Optional alternating control by relay, 24-hour timer, or 7-day clock
Wide Range Class 1-30 Electronic Overload Prevents ordering confusion and eliminates call backs due to mis-sized heaters Advanced protective features including phase loss, phase imbalance, stall protection & manual reset
Combination Versions Include Disconnect
50
Motor circuit protection disconnect provides branch and short circuit protection High interrupting ratings for maximum electrical system compatibility No fuses required – save time and money Lockable handle for safety
www.westcoastpower.com 1-866-955-0888
PUMP CONTROLS
Ordering and Sizing Information Options Part Number
Description
DPX-ALT
Automatic Alternating Relay
DPX-CLK
7-Day Programmable Clock Alternation
DPX-TMR
24-Hour Timer Alternation
DPX-FLT
Fault Pilot Lights
Basic Duplex Pump Starters - HOA & Electronic Overload Horsepower SCIC NEMA KAIC Single Phase Three Phase Size 115V 230V 200V 230V 460V 575V* @460V 1
UL Type 4
UL Type 4X Fiberglass
1/2
1
1.5
3
3
5
00
DPX4-9/J-5
DPXF-9/J-5
3
5
5
10
15
5
0
DPX4-18/J-22
DPXF-18/J-22
1.5
3
5
7.5
15
20
5
1
DPX4-32/J-22
DPXF-32/J-22
2
5
7.5
10
20
25
5
1
DPX4-32/J-40
DPXF-32/J-40
3
7.5
10
10
25
30
5
2
DPX4-50/J-40
DPXF-50/J-40
3
10
20
20
40
50
5
2
DPX4-50/J-80
DPXF-50/J-80
5
15
30
40
60
60
10
3
DPX4-85/J-80
DPXF-85/J-80
Basic Combination Duplex Pump Starters - HOA & Electronic Overload Horsepower SCIC NEMA KAIC Single Phase Three Phase Size 115V 230V 200V 230V 460V 575V* @460V
UL Type 4
UL Type 4X Fiberglass
1/10
–
–
3/4
3/4
65
00
DPX4-9/J-G1.6-5
DPXF-9/J-G1.6-5
1/6
1/2
1/2
1
1.5
65
00
DPX4-9/J-G2.5-5
DPXF-9/J-G2.5-5
1/8
1/3
3/4
3/4
2
3
65
00
DPX4-9/J-G4-5
DPXF-9/J-G4-5
1/4
1/2
1
1.5
3
3
65
00
DPX4-9/J-G6-5
DPXF-9/J-G6-5
1/3
1
2
2
5
5
65
0
DPX4-18/J-G8-22
DPXF-18/J-G8-22
1/2
1.5
2
3
5
7.5
65
0
DPX4-18/J-G10-22
DPXF-18/J-G10-22
1/2
2
3
3
7.5
10
65
0
DPX4-18/J-G13-22
DPXF-18/J-G13-22
1
3
3
5
10
15
30
0
DPX4-18/J-G17-22
DPXF-18/J-G17-22
1.5
3
5
7.5
15
20
30
1
DPX4-32/J-G22-40
DPXF-32/J-G22-40
2
3
7.5
7.5
15
20
30
1
DPX4-32/J-G26-40
DPXF-32/J-G26-40
2
5
7.5
10
20
25
30
1
DPX4-32/J-G32-40
DPXF-32/J-G32-40
3
7.5
10
10
30
30
50
2
DPX4-50/J-G40-40
DPXF-50/J-G40-40
3
10
15
15
30
40
50
2
DPX4-50/J-G50-80
DPXF-50/J-G50-80
5
10
20
20
40
50
50
3
DPX4-85/J-G63-80
DPXF-85/J-G63-80
5
15
20
25
50
60
50
3
DPX4-85/J-G75-80
DPXF-85/J-G75-80
* For 600V part numbers please consult factory. ++ For starters over NEMA Size 3 consult factory.
51
INDUSTRIAL CATALOG
Advanced Duplex Pump Controller 1Ø & 3Ø, 115~600VAC, 1–200HP PLC-Based Lead/Lag & Alternating Float Switch Inputs
NEMA Sized
Engineered for the Most Demanding Pumping Applications The Advanced Duplex Pump Starter is ideal for wastewater lift stations or other redundant pump systems. Cerus designed the package specifically for float switch controlled pump stations utilizing lead-lag and alternating control. Cerus provides single or dual pump automatic operation based on demand including alternating function. In the event of a lead pump failure, Cerus increases system reliability by initiating lag pump start to ensure continued flow.
Time Saving Features & Standard Components
Integrated controls lead/lag & alternating operation Door-mounted Alarm pilot light indicates high level alarm & float switch failure (identifies specific float number) Optional circuit breaker or service entrance rated MCCB Flexible control for three, four or five float switch systems Automatic alternating control
Hand/Off/Auto switches for independent local or remote operation Dual Run pilot lights indicate motor operation Adjustable time for lag start delay and alternation settings Fault and Alarm contact outputs allow integration with external devices
Wide Range Class 1-30 Electronic Overload Prevents ordering confusion and eliminates call backs due to mis-sized heaters Advanced protective features including phase loss, phase imbalance, stall protection & manual reset
Combination Versions Include Disconnect
Motor circuit protection disconnect provides branch and short circuit protection High interrupting ratings for maximum electrical system compatibility No fuses required – save time and money Lockable handle for safety
Options
52
Elapsed-time meter for each pump Fault lights for each pump Door-mounted overload reset pushbuttons Alarm beacon light Horn or buzzer with silence pushbutton
www.westcoastpower.com 1-866-955-0888
120VAC output for external alarm light Motor seal failure relay for each pump (Motor should have a resistive float switch or probe) Motor overheat relay (motor should have an internal thermostat)
PUMP CONTROLS
Ordering and Sizing Information Options Part Number
Description
APX-FLT
Fault Pilot Lights
APX-DHM
Digital Hour Meter
APX-BCN
Alarm Beacon Light
APX-HRN
Door Mounted Horn w/ Silence Pushbutton
APX-BZR
Door Mounted Buzzer w/ Silence Pushbutton
APX-LSR
Leak Seal Relays
Advanced Duplex Pump Starters - HOA & Electronic Overload Single Phase 115V 230V
Horsepower SCIC NEMA KAIC Three Phase Size 200V 230V 460V 575V* @460V
1/2
1
UL Type 4
UL Type 4X Fiberglass
1.5
3
3
5
00
APX4-9/J-5
APXF-9/J-5
1
3
5
5
10
15
5
0
APX4-18/J-22
APXF-18/J-22
1.5
3
5
7.5
15
20
5
1
APX4-32/J-22
APXF-32/J-22
2
5
7.5
10
20
25
5
1
APX4-32/J-40
APXF-32/J-40
3
7.5
10
10
25
30
5
2
APX4-50/J-40
APXF-50/J-40
3
10
20
20
40
50
5
2
APX4-50/J-80
APXF-50/J-80
5
15
30
40
60
60
10
3
APX4-85/J-80
APXF-85/J-80
Advanced Combination Duplex Pump Starters - HOA & Electronic Overload Single Phase 115V 230V
Horsepower SCIC NEMA KAIC Three Phase Size 200V 230V 460V 575V* @460V
1/10
–
–
3/4
3/4
65
UL Type 4
UL Type 4X Fiberglass
00
APX4-9/J-G1.6-5
APXF-9/J-G1.6-5
1/6
1/2
1/2
1
1.5
65
00
APX4-9/J-G2.5-5
APXF-9/J-G2.5-5
1/8
1/3
3/4
3/4
2
3
65
00
APX4-9/J-G4-5
APXF-9/J-G4-5
1/4
1/2
1
1.5
3
3
65
00
APX4-9/J-G6-5
APXF-9/J-G6-5
1/3
1
2
2
5
5
65
0
APX4-18/J-G20-22
APXF-18/J-G20-22
1/2
1.5
2
3
5
7.5
65
0
APX4-18/J-G25-22
APXF-18/J-G25-22
1/2
2
3
3
7.5
10
65
0
APX4-18/J-G30-22
APXF-18/J-G30-22
1
3
3
5
10
15
30
0
APX4-18/J-G50-22
APXF-18/J-G50-22
1.5
3
5
7.5
15
20
30
1
APX4-32/J-G60-40
APXF-32/J-G60-40
2
5
7.5
10
20
25
30
1
APX4-32/J-G80-40
APXF-32/J-G80-40
3
7.5
10
10
30
30
50
2
APX4-50/J-G100-40
APXF-50/J-G100-40
3
10
15
15
30
40
50
2
APX4-50/J-G125-80
APXF-50/J-G125-80
5
10
20
20
40
50
50
3
APX4-85/J-G160-80
APXF-85/J-G160-80
5
15
20
25
50
60
50
3
APX4-85/J-G200-80
APXF-85/J-G200-80
* For 600V part numbers please consult factory. ++ For starters over NEMA Size 3 consult factory.
53
INDUSTRIAL CATALOG
Enclosed VFD Pump Package
1Ø & 3Ø Input, 200~230VAC & 480VAC, 1–125HP Phase Conversion Capabilities UL Type 3R Enclosure
Responsive Control for Demand Driven Pump Systems For pumping applications that require constant discharge pressure, Cerus provides a package that varies the flow rate to maintain a pressure set point. Gain increased energy savings from demand-based pump usage including Sleep Mode, which continues to monitor system set point while stopping VFD output during periods of low demand.
Designed to Withstand Harsh Pumping Environments P-Series VFD motor control with additional application-specific protective options - Lightning/Surge Arrestor - Line Reactors - Load Reactors - dV/dT Filter UL Type 3R enclosure reduces thermal absorption with white, solar reflective finish and filtered cooling fans Standard enclosed VFD package is rated for 92° F outside temperature, non-direct sunlight Attain up to 110° F outside temperature, non-direct sunlight by de-rating VFD
Functionality
54
A single VFD has the capability to control up to four additional pump starters, VFDs, or soft starters in lead-lag operation, reducing the need for additional controls Sleep mode reduces energy consumption by stopping pumps during periods of low demand Flexible sensor inputs accept 0-10VDC and 4-20mA analog signals VFD provides additional 12VDC and 24VDC power for sensors Dual PID control with Pre-PID mode and time delay reduces water hammer and cavitation while providing precise system control
www.westcoastpower.com 1-866-955-0888
PUMP CONTROLS
Ordering and Sizing Information Options Part Number
Description
VFD-RPL/120
Run Pilot Light for Type 12 & 3R (Green Standard)
VFD-FLT/120
Fault Pilot Light for Type 12 & 3R (Red Standard)
VFD-OFF/120
Off Pilot Light for Type 12 & 3R (Red Standard)
VFD-HOA
Hand-Off-Auto Switch for Enclosed Drives
VFD-SPD
Door Mounted Speed Potentiometer
VFD-LTA
Lightning Arrestor
VFD-KPD
Door Mounted Keypad
VFD-KPD/4X
Door Mounted Keypad with Type 4X Cover
UL Type 3R VFD Pump Packages (3-Phase, 200~230V) 1Ø HP*
HP
FLA
Part Number
3% Line Reactor
Output Reactor
Output Filter
2
5
24
CIE3R-PMP005-P2
VFD-KDRB22L
VFD-KDRD1P
VFD-V1K16A00
3
7.5
24
CIE3R-PMP007-P2
VFD-KDRB23L
VFD-KDRD2P
VFD-V1K25A00
5
10
32
CIE3R-PMP010-P2
VFD-KDRD25L
VFD-KDRD3P
VFD-V1K35A00
7.5
15
46
CIE3R-PMP015-P2
VFD-KDRD24L
VFD-KDRC1P
VFD-V1K45A00
10
20
60
CIE3R-PMP020-P2
VFD-KDRD26L
VFD-KDRF1P
VFD-V1K55A00
10
25
74
CIE3R-PMP025-P2
VFD-KDRC22L
VFD-KDRF2P
VFD-V1K80A00
15
30
88
CIE3R-PMP030-P2
VFD-KDRF24L
VFD-KDRF3P
VFD-V1K80A00
20
40
115
CIE3R-PMP040-P2
VFD-KDRF25L
VFD-KDRH1P
VFD-V1K110A00
* Maximum HP of 3-phase motor in single phase power applications
UL Type 3R VFD Pump Packages (3-Phase, 380~480V) 1Ø HP*
HP
FLA
Part Number
3% Line Reactor
Output Reactor
Output Filter
2
5
12
CIE3R-PMP005-P4
VFD-KDRA3L
VFD-KDRA3P
VFD-V1K8A00
3
7.5
12
CIE3R-PMP007-P4
VFD-KDRA4L
VFD-KDRA4P
VFD-V1K12A00
5
10
16
CIE3R-PMP010-P4
VFD-KDRA5L
VFD-KDRB1P
VFD-V1K18A00
7.5
15
24
CIE3R-PMP015-P4
VFD-KDRB2L
VFD-KDRD1P
VFD-V1K21A00
10
20
30
CIE3R-PMP020-P4
VFD-KDRB1L
VFD-KDRD2P
VFD-V1K27A00
10
25
39
CIE3R-PMP025-P4
VFD-KDRD1L
VFD-KDRD3P
VFD-V1K35A00
15
30
45
CIE3R-PMP030-P4
VFD-KDRD2L
VFD-KDRD4P
VFD-V1K45A00
20
40
61
CIE3R-PMP040-P4
VFD-KDRC1L
VFD-KDRC1P
VFD-V1K55A00
20
50
75
CIE3R-PMP050-P4
VFD-KDRF2L
VFD-KDRF1P
VFD-V1K80A00
20
60
91
CIE3R-PMP060-P4
VFD-KDRF4L
VFD-KDRF2P
VFD-V1K80A00
20
75
110
CIE3R-PMP075-P4
VFD-KDRF3L
VFD-KDRF3P
VFD-V1K110A00
20
100
152
CIE3R-PMP0100-P4
VFD-KDRH3L
VFD-KDRH1P
VFD-V1K130A00
20
125
183
CIE3R-PMP0125-P4
VFD-KDRH2L
VFD-KDRI1P
VFD-V1K160A00
* Maximum HP of 3-phase motor in single phase power applications
55
INDUSTRIAL CATALOG
Advanced Duplex VFD Pump Package 1Ø & 3Ø Input, 200~230VAC & 480VAC, 1–125HP Phase Conversion Capabilities UL Type 3R Enclosure
Engineered for the Most Demanding Pumping Applications The Advanced Duplex VFD Pump package is ideal for domestic water pump and booster pump systems. Cerus designed the package specifically to maintain a pressure set point based on sensor feedback using internal PID control. This package provides the most economic pump control solution by reducing both energy and maintenance costs.
Maintain System Pressure with Single Sensor Feedback
Integrated controls lead/lag & alternating operation Optional circuit breaker or service entrance rated MCCB Single pressure transducer provides feedback for both PID control loops Automatic alternating control
Options
56
Run pilot lights Fault pilot lights Off pilot lights Door-mounted potentiometer Door-mounted keypad Door-mounted keypad with Type 4X cover
www.westcoastpower.com 1-866-955-0888
Hand/Off/Auto switches for independent local or remote operation Adjustable time for lag start delay and alternation settings Fault contact output allow integration with external devices
PUMP CONTROLS
Ordering and Sizing Information Options Part Number
Description
VFD-RPL/120
Run Pilot Light for Type 12 & 3R (Green Standard)
VFD-FLT/120
Fault Pilot Light for Type 12 & 3R (Red Standard)
VFD-OFF/120
Off Pilot Light for Type 12 & 3R (Red Standard)
VFD-SPD
Door Mounted Speed Potentiometer
VFD-LTA
Lightning Arrestor
VFD-KPD
Door Mounted Keypad
VFD-KPD/4X
Door Mounted Keypad with Type 4X Cover
UL Type 3R VFD Pump Packages (3-Phase, 200~230V) 1Ø HP*
HP
FLA
Part Number
3% Line Reactor
Output Reactor
Output Filter
2
5
24
CIE3R-ADP005-P2
VFD-KDRB22L
VFD-KDRD1P
VFD-V1K16A00
3
7.5
24
CIE3R-ADP007-P2
VFD-KDRB23L
VFD-KDRD2P
VFD-V1K25A00
5
10
32
CIE3R-ADP010-P2
VFD-KDRD25L
VFD-KDRD3P
VFD-V1K35A00
7.5
15
46
CIE3R-ADP015-P2
VFD-KDRD24L
VFD-KDRC1P
VFD-V1K45A00
10
20
60
CIE3R-ADP020-P2
VFD-KDRD26L
VFD-KDRF1P
VFD-V1K55A00
10
25
74
CIE3R-ADP025-P2
VFD-KDRC22L
VFD-KDRF2P
VFD-V1K80A00
15
30
88
CIE3R-ADP030-P2
VFD-KDRF24L
VFD-KDRF3P
VFD-V1K80A00
20
40
115
CIE3R-ADP040-P2
VFD-KDRF25L
VFD-KDRH1P
VFD-V1K110A00
* Maximum HP of 3-phase motor in single phase power applications
UL Type 3R VFD Pump Packages (3-Phase, 380~480V) 1Ø HP*
HP
FLA
Part Number
3% Line Reactor
Output Reactor
Output Filter
2
5
12
CIE3R-ADP005-P4
VFD-KDRA3L
VFD-KDRA3P
VFD-V1K8A00
3
7.5
12
CIE3R-ADP007-P4
VFD-KDRA4L
VFD-KDRA4P
VFD-V1K12A00
5
10
16
CIE3R-ADP010-P4
VFD-KDRA5L
VFD-KDRB1P
VFD-V1K18A00
7.5
15
24
CIE3R-ADP015-P4
VFD-KDRB2L
VFD-KDRD1P
VFD-V1K21A00
10
20
30
CIE3R-ADP020-P4
VFD-KDRB1L
VFD-KDRD2P
VFD-V1K27A00
10
25
39
CIE3R-ADP025-P4
VFD-KDRD1L
VFD-KDRD3P
VFD-V1K35A00
15
30
45
CIE3R-ADP030-P4
VFD-KDRD2L
VFD-KDRD4P
VFD-V1K45A00
20
40
61
CIE3R-ADP040-P4
VFD-KDRC1L
VFD-KDRC1P
VFD-V1K55A00
20
50
75
CIE3R-ADP050-P4
VFD-KDRF2L
VFD-KDRF1P
VFD-V1K80A00
20
60
91
CIE3R-ADP060-P4
VFD-KDRF4L
VFD-KDRF2P
VFD-V1K80A00
20
75
110
CIE3R-ADP075-P4
VFD-KDRF3L
VFD-KDRF3P
VFD-V1K110A00
20
100
152
CIE3R-ADP0100-P4
VFD-KDRH3L
VFD-KDRH1P
VFD-V1K130A00
20
125
183
CIE3R-ADP0125-P4
VFD-KDRH2L
VFD-KDRI1P
VFD-V1K160A00
* Maximum HP of 3-phase motor in single phase power applications
57
VARIABLE FREQUENCY
DRIVES
Featuring Space Vector Modulation
Reduced harmonic distortion, torque ripple, and current ripple* Motors run cooler, smoother with greater torque and efficiency
* As compared to typical sinusoidal pulse width modulation
C Series
GS Series
Micro-Single Phase
Compact Space Vector VFD Dual Rated Optimized
Description
A fully capable micro drive that accepts single phase input and provides three phase space vector pulse width modulated output.
An economical, compact and full-featured micro drive delivers high performance control through programmable inputs, PID operation and communications.
Dual-rated for either variable or constant torque applications. Integrated communications, dual PID control and sleep mode maximize installation flexibility.
Horsepower Range
1/2~3HP
1/2~5HP
7.5~400HP
Voltage Ratings
Input
1Ø, 200~230V (+10%, -15%)
3Ø, 200~230V (+10%, -15%) 3Ø, 380~480V (+10%, -15%)
3Ø, 200~230V (+10%, -15%) 3Ø, 380~480V (+10%, -15%)
Output
200~230V
3Ø, 200~230V 3Ø, 380~480V
3Ø, 200~230V 3Ø, 380~480V
Input
50-60Hz
50-60Hz
50-60Hz
Output
0-400Hz
0-400Hz
0-120Hz
User Interface
3-Character LED Display with 4-Direction Keypad & Potentiometer
4-Character LED Display with 4-Direction Keypad
32-Character Backlit LCD Display with Keypad
Digital Inputs
5 Programmable
8 Programmable
8 Programmable
Analog Inputs
0-10VDC & 4-20mA
0-10VDC & 4-20mA
0-10VDC & 4-20mA
Analog Outputs
0-10VDC
0-10VDC
0-10VDC
Enclosure
Open Chassis (IP20)
UL Type 1 (Optional)
UL Type 1 (Standard)
Frequency Ranges
P Series
INDUSTRIAL CATALOG
Micro-Single Phase C Series VFD
0.5–3HP Input 1Ø, 230VAC - Output 3Ø, 230VAC Space Vector Pulse Width Modulation
Standard Features
S ensorless & space vector control (Space Vector PWM by IGBT) 150% torque at 0.5Hz. 1~400Hz output frequency Heavy duty: rated at 100% load at 15kHz carrier frequency
Intuitive Interface, Easy to Program
PID control for built-in process applications Built-in potentiometer Programmable I/O PNP/NPN selectable digital inputs 0~10VDC analog output (PWM) Optional ModBus communications Ground fault protection Built-in RFI filter (Class A)
The C-Series interface features a jogwheel and LED display.
Terminal connections on the C-Series drive allow for easy setup.
60
Easy user setup Improved torque at low speed Optimized motor control Auto-tuning algorithm simplifies commissioning
www.westcoastpower.com 1-866-955-0888
VARIABLE FREQUENCY DRIVES
Specifications Output Ratings Input Ratings
Operation
Input Signal
Voltage (V) Frequency (Hz) Voltage (V) Frequency (Hz) Control method Frequency setting resolution Frequency setting accuracy V/F ratio Overload capacity Torque boost Assigned terminals Programmable input terminals Analog output Operator control Frequency setting Start signal Multi-step operation Multi-step accel./decel. time Operational functions
Three phase, 200~230V 0~400Hz Single phase, 200~230V (±10%) 50~60Hz (±5%) Sensorless vector, V/F control (Space vector PWM) Digital reference: 0.01Hz (below 99Hz) & 0.1Hz (100Hz and over), Analog reference: 0.03Hz at 50Hz Digital: 0.01% of maximum output frequency, Analog: 0.1% of maximum output frequency Linear, Square, User V/F 1 minute at 150%, 30 seconds at 200% (with inverse characteristic proportional to time) Auto, Manual (0~15%) FX (forward), RX (reverse), BX (inverter stop input), RST (reset), JOG (jog) 5 digital Inputs 0~10V Linear 3 digit LED keypad, Terminals, ModBus communication Analog: 0~10V, 4~20mA, Digital: Keypad, Communication: ModBus Forward, Reverse Setting up to 8 speeds (using multi-function terminal) 0.1~6000 seconds. Maximum 8 pre-defined steps using multi-function terminals DC braking, Frequency limit, Frequency jump, Second motor function, Slip compensation, Reverse rotation prevention, Auto restart, PID controls
Emergency stop Interrupting output from inverter Jog Jog operation at 10Hz Fault reset Resets fault signal when protective function is active Operational status
Output Signal
Protective Functions
Operating Environment
Dimensions (H x W x D) Weight (lbs)
Frequency detection, Overload alarm, Stall, Overvoltage, Undervoltage, Inverter overheat, Run, Stop, Constant speed, Speed search, Fault output (relay and open collector output)
Indicator Output frequency, Output current, Output voltage, DC voltage, RPM Overvoltage, Undervoltage, Overcurrent, Inverter overheat, Motor overheat, I/O phase loss, I/O miss wiring, Trip Overload, Speed command loss, Hardware fault, Communication error Alarm Stall; Overload Ambient temperature -10°~ 40° C Storage temperature -20°~ 65° C Humidity 90% Relative Humidity maximum (non-condensing) Altitude & Vibration 1000m max, 5.9m/sec2(0.6g) max. Application site No corrosive gas, flammable gas, oil mist or dust CI-000-C2, CI-001-C2 5.63” x 3.11” x 5.63” CI-002-C2, CI-003-C2 5.63” x 6.14” x 5.63” CI-000-C2, CI-001-C2 2.9 lbs CI-002-C2, CI-003-C2 5.4 lbs
Micro-Single Phase C-Series VFD HP
kW
Capacity (kVA)
FLA
Part Number
3% Line Reactor*
1/2
0.4
0.95
2.5
CI-000-C2-1P
KDRULA54LE01
1
0.75
1.9
5
CI-001-C2-1P
KDRULA25LE01
2
1.5
3
8
CI-002-C2-1P
KDRULA27LE01
3
2.2
4.5
12
CI-003-C2-1P
KDRULA28LE01
* Line Reactors housed in separate UL Type 1 Enclosure
Option Description
Part Number
ModBus communication card
CI-MB-COM-C
61
INDUSTRIAL CATALOG
Compact GS Series VFD 0.5–5HP
200~230VAC, 380~480VAC, 3Ø Compact Design, Sensorless & VF Control
Intelligent High Performance P recise control and high starting torque (up to 150% at 0.5 Hz (Space Vector PWM by IGBT) Auto carrier frequency adjusts inversely in relation to temperature of drive for long term reliability Ground fault protection of output terminal during run Quiet operation thanks to fan control coordination with motor start/stop
Easy To Set Up and Operate
With sensorless control the GS series makes motor control easy.
ew 4-direction keypad makes parameter settings a snap N Operation algorithm helps prevent nuisance tripping Auto & manual torque boost Optimum acceleration and deceleration curves set automatically for maximum torque - or choose one of three different patterns 8 preset speeds
Flexible
62
ModBus & 485 communication for easy integration Built-in dynamic braking unit (external resistor required) Remote keypad mounting available for flexible installation options Built-in fault memory (stores last five fault conditions)
www.westcoastpower.com 1-866-955-0888
The easy to use 4-direction keypad makes settings a snap.
VARIABLE FREQUENCY DRIVES Specifications Output ratings Input ratings
Operation
Voltage (V) Frequency (Hz) Voltage (V) Frequency (Hz) Control method Frequency setting resolution Frequency setting accuracy V/F ratio Overload capacity Torque boost Assigned terminals Programmable input Analog output Operator control Frequency setting Start signal Multi-step operation
Three phase, 200~230V or Three phase, 380~480V 0~400Hz Three phase, 200~230V (+10%, -15%) or Three phase, 380~480V (+10%, -15%) 50~60Hz (±5%) Sensorless Vector, V/F control (Space vector PWM) Digital reference: 0.01Hz (below 99Hz) & 0.1Hz (100Hz and over); Analog reference: 0.03Hz at 50Hz Digital: 0.01% of maximum output frequency; Analog: 0.1% of maximum output frequency Linear; Square; User V/F 1 minute at 150%; 30 seconds at 200% (with inverse characteristic proportional to time) Auto; Manual (0~15%) FX (forward), RX (reverse), BX (inverter gate blocking), RST (reset), JOG (jog) 8 digital inputs 0~10V linear 4 digit LED display/keypad, Terminals, ModBus communication Analog: 0~10V, 4~20mA, Digital: Keypad, Communication: ModBus Forward, Reverse Setting up to 8 speeds (using multi-function terminal)
Multi-step 0.1~6000 seconds. Maximum 8 pre-defined steps using multi-function terminals accel./decel. time
Input signal
Operational functions
DC braking, Frequency limit, Frequency jump, Second motor function, Slip compensation, Reverse rotation prevention Auto restart, PID controls
Emergency stop Interrupting output from inverter Jog Jog operation Fault reset Resets fault signal when protective function is active Operational status
Output signal
Frequency detection, Overload alarm, Stall, Overvoltage, Undervoltage, Inverter overheat, Run, Stop, Constant speed, Speed search, Fault output (relay and open collector output)
Indicator Output frequency, Output current, Output voltage, DC voltage, rpm Trip
Protective functions
Alarm Ambient temperature Storage temperature Operating Humidity environment Altitude & Vibration Application site CI-000-GS2/GS4, CI-001-GS2/GS4 Dimensions CI-002-GS2/GS4 (H x W x D) CI-003-GS2/GS4, CI-005-GS2/GS4 CI-000-GS2/GS4, CI-001-GS2/GS4 Weight (lbs) CI-002-GS2/GS4 CI-003-GS2/GS4, CI-005-GS2/GS4
Overvoltage, Undervoltage, Overcurrent, Inverter overheat, Motor overheat, I/O phase loss, I/O mis-wiring, Overload, Speed command loss, Hardware fault, Communication error Stall, Overload -10°~ 50° C -20°~ 65° C 90% Relative Humidity maximum (non-condensing) 1000m max, 5.9m/sec2(0.6g) max. No corrosive gas, flammable gas, oil mist or dust 5.04” x 2.76” x 5.12” (Height is 6.90” w/ NEMA kit) 5.04” x 3.94” x 5.12” (Height is 6.90” w/ NEMA kit) 5.04” x 5.51” x 6.10” (Height is 6.90” w/ NEMA kit) 1.7 lbs 2.5 lbs 4.1 lbs
GS Series VFD (3-Phase, 200~230V) HP
kW
Capacity (kVA)
FLA
Part Number
NEMA 1 Kit
1/2
0.4
0.95
2.5
CI-000-GS2
CI-NEMA1-GS/A
3% Line Reactor* KDRULA54LE01
1
0.75
1.9
5
CI-001-GS2
CI-NEMA1-GS/A
KDRULA25LE01
2
1.5
3
8
CI-002-GS2
CI-NEMA1-GS/B
KDRULA27LE01
3
2.2
4.5
12
CI-003-GS2
CI-NEMA1-GS/C
KDRULA28LE01
5
3.7
6.1
16
CI-005-GS2
CI-NEMA1-GS/C
KDRULB22LE01
* Line Reactors housed in separate UL Type 1 Enclosure
GS Series VFD (3-Phase, 380~480V) HP
kW
Capacity (kVA)
FLA
Part Number
NEMA 1 Kit
3% Line Reactor*
1/2
0.4
0.95
1.25
CI-000-GS4
CI-NEMA1-GS/A
KDRULA6LE01
1
0.75
1.9
2.5
CI-001-GS4
CI-NEMA1-GS/A
KDRULA8LE01
2
1.5
3
4
CI-002-GS4
CI-NEMA1-GS/B
KDRULA1LE01
3
2.2
4.5
6
CI-003-GS4
CI-NEMA1-GS/C
KDRULA2LE01
5
3.7
6.1
8
CI-005-GS4
CI-NEMA1-GS/C
KDRULA3LE01
* Line Reactors housed in separate UL Type 1 Enclosure
Options Description
Part Number
Remote Keypad Mounting Kit (2 Meter Cable)
CI-RKPK-EXT2M-GS
Remote Keypad Mounting Kit (3 Meter Cable)
CI-RKPK-EXT3M-GS
Remote Keypad Mounting Kit (5 Meter Cable)
CI-RKPK-EXT5M-GS
63
INDUSTRIAL CATALOG
P-Series VFD
7.5–40HP (200~230VAC), 7.5–400HP (380~480VAC), 3Ø Dual Rated for Constant & Variable Torque Integrated PID Control
Intuitive Keypad Interface, Easy to Program
E asy-set up thanks to 32 character LCD & simplified parameters Each drive ships with easy to follow Quick Start guide Save, download & upload parameter settings to multiple drives with a single keypad DriveView software allows VFD to interface with a PC Displays parameters in plain English
Maximize Energy Savings
Space-vector control for clean sine wave output increasing efficiency and extending motor life Sleep-mode conserves energy when demand level falls below set threshold Automatic self tuning for maximum energy savings Quiet, super smooth 15kHz carrier frequency operation
The 32-character backlit LCD screen displays the drive’s operational status and parameter settings.
Versatile Features for the Most Demanding Applications
64
Sensorless vector control for variable load applications Built-in multi-motor control (for up to 4 additional motors) Dual PID controls Torque boost and stall prevention features guarantees smooth motor starts 8 programmable digital inputs, 2 analog inputs (0-10VDC, 4-20mA) Optional DC braking units ensure quick, controlled deceleration
www.westcoastpower.com 1-866-955-0888
The P-Series clearly marked terminal inputs and outputs allow for easy wiring and setup.
VARIABLE FREQUENCY DRIVES
Specifications Output ratings Input ratings
Operation
Voltage (V) Frequency (Hz) Voltage (V) Frequency (Hz) Input Power Factor Drive Efficiency Control method Frequency setting resolution Frequency setting accuracy V/F ratio Overload capacity Torque boost Multi-function input terminals Analog output
Three phase, 200~230V, Three phase, 380~480V 0~120Hz Three phase, 200~230V (-15%, +10%), Three phase, 380~480V (-15%, +10%) 50~60Hz (±5%) <.95 from no load to full load >96% V/F control, Sensorless vector control Digital reference: 0.01Hz (below 99Hz) & 0.1Hz (100Hz and over); Analog reference: 0.06Hz at 60Hz Digital: 0.01% of maximum output frequency; Analog: 0.1% of maximum output frequency Linear, Square, User V/F 1 minute at 120%, 10 seconds at 150% (with inverse characteristic proportional to time) Auto, Manual (0~15%) Total 8 inputs (programmable) 0~10V linear
LCD keypad, Terminals, ModBus-RTU communication Operator control 32-character Optional ModBus-RTU, RS485, ProfiBus-DP, DeviceNet, F-Net Frequency setting Analog: 0~10V, 4~20mA, additional port for Sub-Board (0~10V); Digital: Keypad, Communication Start signal Forward, Reverse Multi-step operation Setting up to 8 speeds (using multi-function terminal) Multi-step accel/decel time 0.1~6000 seconds. Maximum 8 pre-defined steps using multi-function terminals
Input signal
Operational DC braking, Frequency limit, Frequency jump, Second motor function, Slip compensation, Reverse rotation prevention, functions Auto start, Inverter bypass, Auto-tuning, Dual PID control Emergency stop Auto operation Jog Fault reset Output signal
Interrupting output from inverter Operates from internal sequence by setting multi-function terminal (5 way x 8 step) Jog operation Resets fault signal when protective function is active
Operational status Frequency detection, Overload alarm, Stall, Overvoltage, Undervoltage, Inverter overheat, Run, Stop, Constant speed, Speed search, Fault output (relay and open collector output), Inverter bypass, Auto-operation sequence Indicator Output frequency, Output current, Output voltage, DC voltage, Output torque (output voltage: 0~10V) Undervoltage, Overcurrent, Inverter overheat, Motor overheat, I/O phase loss, I/O miss wiring, Fuse open, Trip Overvoltage, Ground fault, External fault 1, 2, Option fault, Overload, Speed command loss, Hardware fault, Communication error
Protective functions
Operating environment
Alarm Ambient temperature Storage temperature Humidity Altitude-vibration Application site
Stall, Overload *Temperature sensor fault -10°~40° C -20°~65° C Less than 90% Relative Humidity maximum (non-condensing) Below 1,000m or 3,300ft. below 59 (=0.6g) No corrosive gas, combustible gas, oil mist or dust
Dimensions
Multi-Function Inputs
Programmable inputs for flexible system integration
Sleep Mode
Drive shuts down at low loads; CPU idles until demand increases
Flying Start
Drive matches motor speed at start-up
Dynamic Braking
Speed reductive capability
Auto Energy Savings
Self optimizing regulation to slash kWh Track energy consumption with no added cost!
Multi-Motor Control
Control up to 4 additional motors
Model
Height (w/NEMA kit)
Width
Depth
Weight
CI-007-P2, CI-007-P4
11.19” (11.19”)
5.91”
6.17”
10.8 lbs.
11.19” (11.19”)
7.88”
7.17”
13.2 lbs.
15.17” (17.88”)
9.85”
7.92”
28.7 lbs.
18.12” (23.59”)
11.98”
9.22”
44.1 lbs.
CI-050-P4
20.28” (25.28”)
11.81”
10.46”
59.5 lbs.
CI-060-P4, CI-075-P4
20.28” (25.28”)
11.81”
11.52”
64.0 lbs.
CI-100-P4, CI-125-P4
23.09” (30.22”)
14.57”
13.29”
94.8 lbs.
CI-150-P4, CI-200-P4
30.26”
20.80”
16.64”
223 lbs.
CI-250-P4
33.23”
20.80”
16.64”
252 lbs.
CI-350-P4, CI-400-P4
41.85”
27.17”
17.70”
441 lbs.
CI-010-P2, CI-010-P4 CI-015-P2, CI-015-P4 CI-020-P2, CI-020-P4 CI-025-P2, CI-025-P4 CI-030-P2, CI-030-P4 CI-040-P2, CI-040-P4
65
INDUSTRIAL CATALOG
Options Description
Part Number
Remote Keypad Mounting Kit (2 Meter Cable)
CI-RKPK-EXT2M-P/S
Remote Keypad Mounting Kit (3 Meter Cable)
CI-RKPK-EXT3M-P/S
Remote Keypad Mounting Kit (5 Meter Cable)
CI-RKPK-EXT5M-P/S
RS485 communication card
CI-R4-COM
DeviceNet communication card
CI-DN-COM
N2 communication card
CI-N2-COM
ProfiBus DP communication card
CI-PB-COM
P-Series VFD (3-Phase, 200~230V) Standard Duty (VT)
Heavy Duty (CT)
HP
kW
FLA
HP
kW
FLA
Part Number
7.5
5.5
24
5
3.7
17
CI-007-P2
KDRULB23LE01
10
7.5
32
7.5
5.5
23
CI-010-P2
KDRULD25LE01
15
11
46
10
7.5
33
CI-015-P2
KDRULD24LE01
20
15
60
15
11
44
CI-020-P2
KDRULD26LE01
25
18.5
74
20
15
54
CI-025-P2
KDRULC22LE01
30
22
88
25
18.5
68
CI-030-P2
KDRULF24LE01
40
30
115
30
22
84
CI-040-P2
KDRULF25LE01
3% Line Reactor*
P-Series VFD (3-Phase, 380~480V) Standard Duty (VT)
66
Heavy Duty (CT)
HP
kW
FLA
HP
kW
FLA
Part Number
3% Line Reactor*
7.5
5.5
12
5
3.7
8
CI-007-P4
KDRULA4LE01
10
7.5
16
7.5
5.5
11
CI-010-P4
KDRULA5LE01
15
11
24
10
7.5
17
CI-015-P4
KDRULB2LE01
20
15
30
15
11
22
CI-020-P4
KDRULB1LE01
25
18.5
39
20
15
28
CI-025-P4
KDRULD1LE01
30
22
45
25
18.5
34
CI-030-P4
KDRULD2LE01
40
30
61
30
22
44
CI-040-P4
KDRULC1LE01
50
37
75
40
30
55
CI-050-P4
KDRULF2LE01
60
45
91
50
37
66
CI-060-P4
KDRULF4LE01
75
55
110
60
45
80
CI-075-P4
KDRULF3LE01
100
75
152
75
55
111
CI-100-P4
KDRULH3LE01
125
90
183
100
75
134
CI-125-P4
KDRULH2LE01
150
110
223
125
90
183
CI-150-P4
KDRULH1LE01
200
132
264
150
110
223
CI-200-P4
KDRULG3LE01
250
160
325
200
132
264
CI-250-P4
KDRULG1LE01
350
220
432
250
160
325
CI-350-P4
KDRULJ2LE01
400
280
547
300
220
432
CI-400-P4
KDRULJ1LE01
www.westcoastpower.com 1-866-955-0888
VARIABLE FREQUENCY DRIVES
Dynamic Braking Units & Resistors 100% Braking Torque & 10% Duty Cycle Compatible with P Series VFD Enclosed IP20 ChassisUL Type 3R
Responsive Braking For Maximum Process Control
Resistors Sized to Dynamic Braking Unit’s Maximum Capacity Flexible sizing options using single or multiple units to meet braking requirements Built-in thermostat protects from overheating by tripping VFD if wired to digital input Combine resistors in series or in parallel connections to achieve requirements for custom applications
Dynamic Braking Units & Resistors (200~230VAC) Max HP
Part Number
DB Resistor Part Number
Min Ohms
kW
20
CI-DBU-20-2
DB8D50-3K20-10600AA0
8.5Ω
3.2
30
CI-DBU-30-2
DB5D8-5K0-10900AA0
5.8Ω
5.0
50
CI-DBU-40-2
DB4D5-6K5-10900AA0
4.5Ω
6.5
75
CI-DBU-50-2
DB3D0-10K0-10900AA0
3.0Ω
10.0
Dynamic Braking Units & Resistors (380~480VAC) Max HP
Part Number
DB Resistor Part Number
Min Ohms
kW
20
CI-DBU-20-4
DB34D0-3K20-10600AA0
34.0Ω
3.2
30
CI-DBU-30-4
DB23D0-5K00-10900AA0
23.0Ω
5.0
50
CI-DBU-40-4
DB17D0-6K50-10900AA0
17.0Ω
6.5
75
CI-DBU-50-4
DB11D5-10K0-10900AA0
11.5Ω
10.0
100
CI-DBU-60-4
DB8D50-13K0-11800AA0
8.5Ω
13.0
DBU & Resistor Sizing Guide Application
P-Series VFD
Dynamic Braking Unit
Multiplier (x HP)
Fans, Blowers & Pumps
1.0
Pump Jacks, Washing Machines, Presses & E-Stop Systems
1.5
Twisted Wires 30” max
POWER RUN OHT OCT
Cranes, Hoists, High-Inertia Turntables & Elevators
2.0
FOT
Resistor Twisted Wires 30” max
Thermostat Contact
M
67
ENGINEERED
SOLUTIONS
Because not every motor control application is the same, we offer engineered solutions for our starter and VFD products. Modifications include a full range of enclosure options capable of withstanding almost any environment, complex multi-motor control, or simply ensuring the controls follow a specific sequence of operations. We respond, often times with same day quotes depending on application complexity and job requirements.
BYPASSES & ENCLOSED DRIVES
Contact Cerus for More Information
Cerus P-Drive with Space Vector Control for high efficiency and enhanced motor life Fully-enclosed drive options Bypass cabinets with hinged enclosures and easy access terminal inputs Door mounted control options including HOA and VFD/Off/Bypass switches, speed potentiometer and pilot lights Two and Three contactor bypass configurations with disconnect options Panel space heaters available for ambient temperatures below 32° F
INDUSTRIAL CATALOG
Optimized Line Reactors 3 Phase, 600V Class UL & CE Marked Open Chassis & UL Type 1
Features
Optimized Line Reactors (200~230V)
Reduces input line distortion Eliminates transient and overvoltage nuisance tripping Provides maximum harmonic mitigation without adding capacitance Improve true power factor Helps to prevent VFD component damage
3%
5%
HP
Open Chassis
UL Type 1 Enclosed
Open Chassis
UL Type 1 Enclosed
1/2 3/4 1 1.5 2 3 5 7.5 10 15 20 25 30 40
KDRA54L KDRA53L KDRA25L KDRA26L KDRA27L KDRA28L KDRB22L KDRB23L KDRD25L KDRD24L KDRD26L KDRC22L KDRF24L KDRF25L
KDRULA54LE01 KDRULA53LE01 KDRULA25LE01 KDRULA26LE01 KDRULA27LE01 KDRULA28LE01 KDRULB22LE01 KDRULB23LE01 KDRULD25LE01 KDRULD24LE01 KDRULD26LE01 KDRULC22LE01 KDRULF24LE01 KDRULF25LE01
KDRA54H KDRA53H KDRA25H KDRA27H KDRA26H KDRA28H KDRB25H KDRB26H KDRD21H KDRD22H KDRC22H KDRF28H KDRF25H KDRF26H
KDRULA54HE01 KDRULA53HE01 KDRULA25HE01 KDRULA27HE01 KDRULA26HE01 KDRULA28HE01 KDRULB25HE01 KDRULB26HE01 KDRULD21HE01 KDRULD22HE01 KDRULC22HE01 KDRULF28HE01 KDRULF25HE01 KDRULF26HE01
Optimized Line Reactors (380~480V) 3%
Industrial Surge Arrestors Description
Part Number
3-Phase 200~240V
LA-302
3-Phase 440~600V
LA-603
Specifications
70
Maximum current: 100kA Maximum energy: 3000J Unlimited number of surges Response times to clamp: - 1 mA test: 5 ns - 10kA: 10 ns - 50kA: 25 ns
5%
HP
Open Chassis
UL Type 1 Enclosed
Open Chassis
UL Type 1 Enclosed
1/2 3/4 1 1.5 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 350 400
KDRA6L KDRA7L KDRA8L KDRA9L KDRA1L KDRA2L KDRA3L KDRA4L KDRA5L KDRB2L KDRB1L KDRD1L KDRD2L KDRC1L KDRF2L KDRF4L KDRF3L KDRH3L KDRH2L KDRH1L KDRG3L KDRG1L KDRG2L KDRJ2L KDRJ1L
KDRULA6LE01 KDRULA7LE01 KDRULA8LE01 KDRULA9LE01 KDRULA1LE01 KDRULA2LE01 KDRULA3LE01 KDRULA4LE01 KDRULA5LE01 KDRULB2LE01 KDRULB1LE01 KDRULD1LE01 KDRULD2LE01 KDRULC1LE01 KDRULF2LE01 KDRULF4LE01 KDRULF3LE01 KDRULH3LE01 KDRULH2LE01 KDRULH1LE01 KDRULG3LE01 KDRULG1LE01 KDRULG2LE01 KDRULJ2LE01 KDRULJ1LE01
KDRA6H KDRA7H KDRA8H KDRA9H KDRA1H KDRA2H KDRA3H KDRA4H KDRA5H KDRB2H KDRC3H KDRC1H KDRE2H KDRF4H KDRF1H KDRF2H KDRH2H KDRH1H KDRG3H KDRG1H KDRJ1H KDRL1H KDRL2H KDRL3H KDRL4H
KDRULA6HE01 KDRULA7HE01 KDRULA8HE01 KDRULA9HE01 KDRULA1HE01 KDRULA2HE01 KDRULA3HE01 KDRULA4HE01 KDRULA5HE01 KDRULB2HE01 KDRULC3HE01 KDRULC1HE01 KDRULE2HE01 KDRULF4HE01 KDRULF1HE01 KDRULF2HE01 KDRULH2HE01 KDRULH1HE01 KDRULG3HE01 KDRULG1HE01 KDRULJ1HE01 KDRULL1HE01 KDRULL2HE01 KDRULL3HE01 KDRULL4HE01
www.westcoastpower.com 1-866-955-0888
LINE REACTORS
Drive Output Reactors & Filters 3 Phase, 600V Class UL & CE Marked UL Type 1 & 3R Available
Output Reactors
dV/dT Output Filters
Protection for motor leads between 50 - 100 ft Protects VFD output by dampening peak voltage overshoot Extends motor life by reducing heat and audible noise Helps prevent VFD instantaneous overcurrent trips
Optimized Output Reactors Horsepower 240V
480V
3/4 1 2 3 5 7.5 10 15 20 25 30 40 -
2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 350 400
Protection for motor leads exceeding 125 ft Ensures smooth VFD sinusoidal output to motor Extends motor life by reducing heat, audible noise and insulation breakdown Reduces “reflective wave” effect by limiting peak voltage and rise time Helps prevent VFD instantaneous overcurrent trips
Optimized dV/dT Output Filter
Open Chassis
UL Type 1 Enclosed
KDRA1P KDRA2P KDRA3P KDRA4P KDRB1P KDRD1P KDRD2P KDRD3P KDRD4P KDRC1P KDRF1P KDRF2P KDRF3P KDRH1P KDRI1P KDRI2P KDRG1P KDRJ1P KDRJ2P KDRL1P KDRL2P
KDRULA1PE01 KDRULA2PE01 KDRULA3PE01 KDRULA4PE01 KDRULB1PE01 KDRULD1PE01 KDRULD2PE01 KDRULD3PE01 KDRULD4PE01 KDRULC1PE01 KDRULF1PE01 KDRULF2PE01 KDRULF3PE01 KDRULH1PE01 KDRULI1PE01 KDRULI2PE01 KDRULG1PE01 KDRULJ1PE01 KDRULJ2PE01 KDRULL1PE01 KDRULL2PE01
Horsepower 240V
480V
1/2 3/4 1-1.5 2 3 5 7.5 10 15 20 25-30 40 -
3/4 1-1.5 2 3 5 7.5 10 10 15 15 20 25 30 40 50 - 60 75 100 125 150 200 250 300 350 400
Open Chassis
UL Type 1 Enclosed
V1K2A00 V1K3A00 V1K4A00 V1K6A00 V1K8A00 V1K12A00 V1K16A00 V1K18A00 V1K21A00 V1K25A00 V1K27A00 V1K35A00 V1K45A00 V1K55A00 V1K80A00 V1K110A00 V1K130A00 V1K160A00 V1K200A00 V1K250A00 V1K305A00 V1K362A00 V1K420A00 V1K480A00
V1K2A01 V1K3A01 V1K4A01 V1K6A01 V1K8A01 V1K12A01 V1K16A01 V1K18A01 V1K21A01 V1K25A01 V1K27A01 V1K35A01 V1K45A01 V1K55A01 V1K80A01 V1K110A01 V1K130A01 V1K160A01 V1K200A01 V1K250A01 V1K305A01 V1K362A01 V1K420A01 V1K480A01
71
INDUSTRIAL CATALOG
Gage Pressure Sensors 0~500 PSIG Models Stainless Steel Construction 36” Wire Leads, 1/4”-18 NPT
Accurate, Reliable & Versatile Cerus pressure sensors are ideal for industrial and commercial applications where measurement and performance are critical. Additionally, these micro-machined sensors are compact in size, constructed of rugged materials designed to meet the highest standards of chemical compatibility.
Engineered for Superior Accuracy & Performance
±0.5% overall full scale at room temperature ±1% overall full scale over -40°C to 105°C for 75 PSI to 200 PSI Includes repeatability, hysteresis and linearity Custom ASIC provides signal conditioning for calibration and temperature compensation Optional electrical connectors available (Packard, Deutsch, Mini DIN, M12, Integral Harness)
Solid Construction Laser-welded stainless steel design for optimal media isolation Withstands up to three times full scale burst pressure Reverse voltage protected
Gage Pressure Sensors
72
0-5VDC Output
4-20mA Output
Pressure Range
Part Number
Part Number
0-15 PSIG
PG-15SB
PG-15SC
0-25 PSIG
PG-25SB
PG-25SC
0-50 PSIG
PG-50SB
PG-50SC
0-75 PSIG
PG-75SB
PG-75SC
0-100 PSIG
PG-100SB
PG-100SC
0-250 PSIG
PG-250SB
PG-250SC
0-300 PSIG
PG-300SB
PG-300SC
0-500 PSIG
PG-500SB
PG-500SC
www.westcoastpower.com 1-866-955-0888
PRESSURE SENSORS/ TRANSDUCERS
Differential Pressure Transducers 0~2” & 0~25” WC Models Dual Output Signals (4-20mA & 0-5/10VDC) Open Frame & NEMA 4 Enclosure Options
Intrinsic Flow Measurement Technology for High Accuracy
Intrinsic flow measurement results in optimal performance No gravity effect allows mounting in any position LCD display for easy setup and commissioning Switch-selectable pressure ranges Applications include static pressure measurement, variable air volume system control and monitoring filter status
Differential Pressure Transducers - 0”~2” WC Pressure Range 0~1"
0~2”
Enclosure Type
Part Number
Open Frame
PDP30-001
NEMA 4
PDP31-001
NEMA 4 w/ Probe
PDP32-001
Open Frame
PDP30-002
NEMA 4
PDP31-002
NEMA 4 w/ Probe
PDP32-002
Specifications 12-30VDC/24VAC, 30mA maximum (13VDC min for 10V full scale output)
Power Supply Output Type
Dual, 4-20mA & 0-5/10VDC (3-wire) 0-1” (Selectable 0.1, 0.5, 1.0) uni or bi-directional 0-2” (Selectable 0.5, 1”, 2”) uni or bi-directional
Output Scaling Calibrated Temperature Range
32° to 122°F (0-50°C)
Media compatibility Sensor Type Performance
Dry, oil-free air, N2 Digital CMOS intrinsic flow differential pressure
Position Effects Zero point Accuracy Span Accuracy Zero point repeatability Span repeatability Temp offset Temp span shift
None - position insensitive Zero drift 0.5 Pa 3% of reading 0.1 Pa 0.5% of reading None (less than resolution) < 0.5% of reading per 10°C
NEMA 4 enclosed Cerus Pressure Transducer shown with probe.
Selectable Ranges, Outputs and Stable Dry Media Operation
Zero drift technology ensures precision measurement LCD display for easy setup and commissioning Auto zero pushbutton input and auto zero control contact for system accuracy Applications include duct pressure monitoring and air-flow stations Differential Pressure Transducers - 0”~25” WC
Pressure Range 0~10" 0~25"
Enclosure Type
Part Number
NEMA 4
PDP31-010
NEMA 4 w/ Probe
PDP32-010
NEMA 4
PDP31-025
NEMA 4 w/ Probe
PDP32-025
Specifications Power Supply Output Type Output Scaling Calibrated Temperature Range Media Sensor Type Performance Accuracy (Linearity, hysteresis, temperature) Auto-zero input
12-30VDC/24VAC, 30mA maximum (13VDC min for 10V full scale output) Dual, 4-20mA & 0-5/10VDC (3-wire) 0-10” (Selectable 2.5, 5, 10"WC) 0-25” (Selectable 10, 15, 25"WC) 50° to 140°F (10-60°C) Dry, oil-free air, N2 Integrated, micro machined silicon piezoresistive
2.5% full scale Pushbutton and contact closure input provided
73
INDUSTRIAL CATALOG
Economy Soft Starters 2–75HP, 200~600VAC Integrated Bypass Electronic Motor Protection
Extend Equipment Life & Increase Savings Standard Features
Compact, space saving soft start with integrated electronic overload Standard, built-in bypass Aluminum chassis design ensures cool and efficient operation Integrated LED display and control terminals Rated for line or inside delta motor connections
Comprehensive Motor Protection Current limiting and integrated phase loss Starter over-temperature shut down with Reset pushbutton Metal Oxide Varistors (MOV) protect SCRs from damaging surges
Easy Setup & Operation
LED display modes include: On, Ramp Up/Down, Run, Overload, Phase Loss, Over-temp Simple dial adjustments for: Motor FLA, Initial Voltage, Current Limit, Ramp Up/Down Times Adjustable ramp setting ranges (Up/Down 0-30 seconds) End of Acceleration Relay (1 N.O. contact) Fault Output Relay (1 N.O. contact) Auxiliary relays
Economy Soft Starters Horsepower* Max 230V 460V 575V Amps
Part Number
Dimensions H x W x D (in)
Weight (lbs)
2
5
7.5
8
RVS-AX-8
9.5 x 4.75 x 4.25
6
5
10
15
17
RVS-AX-17
9.5 x 4.75 x 4.25
6
10
20
30
31
RVS-AX-31
9.5 x 4.75 x 4.25
6 12
20
40
50
58
RVS-AX-58
11 x 5 x 7.5
25
50
60
72
RVS-AX-72
11 x 5 x 7.5
12
30
60
75
85
RVS-AX-85
15 x 5 x 7.5
14
* Horsepower ratings are for estimation only. Verify actual full load amp requirements.
74
www.westcoastpower.com 1-866-955-0888
SOFT STARTS
Reduced Voltage Analog Soft Starters 3~600HP, 200~600VAC Built-In Motor Protection Open Chassis & Enclosed Options
Full-featured Soft Starter with Dual Operation Modes Standard Features
Compact, space saving design Integrated Class 20 electronic overload protection Reduce peak power consumption during motor starts Slower application torque reduces equipment shock Solid-state reversing option eliminates installation of additional components Dual operation modes to match application needs: - Constant Current mode for light duty or limited power supplies - Current Ramp mode for high inertia or heavy loads Soft stop option controls motor deceleration (eliminates water hammer in pumping applications)
Reduced Voltage Analog Soft Starters Horsepower* Max 230V 460V 575V Amps
Chassis
UL Type 1
UL Type 12
5
10
15
15
SS6-15-CH
SS6-15-N1
SS6-15-N12
10
25
30
30
SS6-30-CH
SS6-30-N1
SS6-30-N12
20
40
50
50
SS6-50-CH
SS6-50-N1
SS6-50-N12
30
60
75
75
SS6-80-CH
SS6-80-N1
SS6-80-N12
50
100
125
125
SS6-125-CH
SS6-125-N1
SS6-125-N12
75
150
200
200
SS6-200-CH
SS6-200-N1
SS6-200-N12
150
300
350
350
SS6-360-CH
SS6-360-N1
SS6-360-N12
200
400
500
500
SS6-500-CH
SS6-500-N1
SS6-500-N12
250
500
600
600
SS6-600-CH
SS6-600-N1
SS6-600-N12
300
600
800
800
SS6-800-CH
SS6-800-N1
SS6-800-N12
* Horsepower ratings are for estimation only. Verify actual full load amp requirements.
75
INDUSTRIAL CATALOG
Reduced Voltage Digital Soft Starters 3–1000HP, 200~600VAC Chassis, NEMA 1 & NEMA 12 Enclosure Options Available Bypass Configuration Option
Extreme Duty Rated Soft Starter For Industrial Demands Display & Control
Keypad and LCD display for easy starter setup, status and diagnostics Soft stop, up-to-speed contact, shorted SCR detection and line/load lugs standard with each unit Enclosed models include control power transformer 120VAC control inputs for: Start/Stop/Jog/Reverse/Reset/Enable Two or three wire control allow for remote operation options Dry contact relay outputs for: Fault/Bypass/Running/Reverse 18-month warranty
Operation & Features
Provides smooth current ramp output to motor eliminating surges and equipment shock Adjustable ramp setting ranges (Up/Down 0-60 seconds) Dual operation modes to match application needs: - Constant Current mode for light duty or limited power supplies - Current Ramp mode for high inertia or heavy loads Jog speeds: Forward at 14% of full speed, Reverse at 20% of full speed DC injection braking option for enhanced performance
Protective Functions
lass 10~30 adjustable electronic overload C 500% overload for 30 seconds guarantees heavy duty operation Single phase protection Instantaneous over-current trip Shorted SCR fault output
Integrated Bypass Rated For Emergency Starts
educes enclosure size and eliminates need for additional cooling R Ensures reliable operation with automatic transition to bypass contactor at full speed Eliminates downtime in critical applications
Specifications Power
3 Phase, 200-600VAC, 50/60Hz
Control*
115VAC 50Hz or 120VAC 60Hz
Digital Inputs Bypass Outputs Analog Input Analog Output Protection Environment Altitude & Vibration
120VAC, 2mA Relay contacts rated at 0.2A, 120VAC 0-10VDC 0-5VDC, 5mA max. Short circuit by fuses or circuit breaker Ambient Temp 0° - 40° C Humidity 90% RH max. (non-condensing) 1000m max, 5.9m/sec2(0.6g) max.
* Control voltage not supplied by soft start. CPT option available in bypass units.
76
www.westcoastpower.com 1-866-955-0888
SOFT STARTS
Ordering and Sizing Information Options Description
Part Number
Door Mounted Keypad (RS232/485)
SFS-DMK
Fault Pilot Light
SFS-FPL
Run Pilot Light
SFS-RPL
Reset Pushbutton
SFS-RST
Two Position Selector Switch
SFS-SSW2
Three Position Selector Switch
SFS-SSW3
Stop Pushbutton (Red)
SFS-STP
Start Pushbutton (Green)
SFS-STR
EtherNetIP Communication Card
SFS-EIP-COM
Reduced Voltage Digital Soft Starters - Standard Units Horsepower* 230V 460V 575V
Chassis
UL Type 12
UL Type 4
UL Type 4X
10
20
30
MS6-30-CH
MS6-30-N12
MS6-30-N4
MS6-30-N4X
20
40
50
MS6-50-CH
MS6-50-N12
MS6-50-N4
MS6-50-N4X
30
60
75
MS6-80-CH
MS6-80-N12
MS6-80-N4
MS6-80-N4X
50
100
125
MS6-125-CH
MS6B-125-N12
MS6B-125-N4
MS6B-125-N4X
75
150
200
MS6-200-CH
MS6B-200-N12
MS6B-200-N4
MS6B-200-N4X
100
200
250
MS6-250-CH
MS6B-250-N12
MS6B-250-N4
MS6B-250-N4X
150
350
400
MS6-420-CH
MS6B-420-N12
MS6B-420-N4
MS6B-420-N4X
200
400
500
MS6-500-CH
MS6B-500-N12
MS6B-500-N4
MS6B-500-N4X
250
500
600
MS6-600-CH
MS6B-600-N12
MS6B-600-N4
MS6B-600-N4X
350
700
800
MS6-800-CH
MS6B-800-N12
MS6B-800-N4
MS6B-800-N4X
Reduced Voltage Digital Soft Starters - Integrated Bypass Units Horsepower* 230V 460V 575V
Non-Fused Disconnect
Fused Disconnect
Circuit Breaker
UL Type 4
UL Type 4X
10
20
30
MS6B-30-N12-NFD
MS6B-30-N12-FD
MS6B-30-N12-CB
SFS-30-N4
SFS-30-N4X
20
40
50
MS6B-50-N12-NFD
MS6B-50-N12-FD
MS6B-50-N12-CB
SFS-50-N4
SFS-50-N4X
30
60
75
MS6B-80-N12-NFD
MS6B-80-N12-FD
MS6B-80-N12-CB
SFS-80-N4
SFS-80-N4X
50
100
125
MS6B-125-N12-NFD
MS6B-125-N12-FD
MS6B-125-N12-CB
SFS-125-N4
SFS-125-N4X
75
150
200
MS6B-200-N12-NFD
MS6B-200-N12-FD
MS6B-200-N12-CB
SFS-200-N4
SFS-200-N4X
100
200
250
MS6B-250-N12-NFD
MS6B-250-N12-FD
MS6B-250-N12-CB
SFS-250-N4
SFS-250-N4X
150
350
400
MS6B-420-N12-NFD
MS6B-420-N12-FD
MS6B-420-N12-CB
SFS-420-N4
SFS-420-N4X
200
400
500
MS6B-500-N12-NFD
MS6B-500-N12-FD
MS6B-500-N12-CB
SFS-500-N4
SFS-500-N4X
250
500
600
MS6B-600-N12-NFD
MS6B-600-N12-FD
MS6B-600-N12-CB
SFS-600-N4
SFS-600-N4X
350
700
800
MS6B-800-N12-NFD
MS6B-800-N12-FD
MS6B-800-N12-CB
SFS-800-N4
SFS-800-N4X
* For 900HP and above, please consult factory for pricing.
DC Injection Braking Units Horsepower 230V 460V 575V
Chassis
UL Type 1
UL Type 12
7.5
15
20
DCI-20-CH
DCI-20-N1
DCI-20-N12
15
30
40
DCI-40-CH
DCI-40-N1
DCI-40-N12
30
60
75
DCI-80-CH
DCI-80-N1
DCI-80-N12
50
100
125
DCI-125-CH
DCI-125-N1
DCI-125-N12
75
150
200
DCI-200-CH
DCI-200-N1
DCI-200-N12
125
250
300
DCI-300-CH
DCI-300-N1
DCI-300-N12
200
400
500
DCI-500-CH
DCI-500-N1
DCI-500-N12
77
INDUSTRIAL CATALOG
Pilot Devices & Accessories Fits 22mm Mounting Patterns UL Type 1, 12, 3R, 4 & 4X
Selector Switches
Legend Plates
2-Position
Type
Part Number
Description
Part Number
Stay Put
CB2-BD2
Spring Return
CB2-BDR2
Start Forward Up On Open Auto Reset Slow Auto-Hand Stop Reverse Down Off Close Hand Inch Fast Hand-Off-Auto Low High High Low Off On Up Down
CB2-PY2303 CB2-PY2305 CB2-PY2307 CB2-PY2311 CB2-PY2313 CB2-PY2315 CB2-PY2323 CB2-PY2327 CB2-PY2364 CB2-PY2304 CB2-PY2306 CB2-PY2308 CB2-PY2312 CB2-PY2314 CB2-PY2316 CB2-PY2321 CB2-PY2328 CB2-PY2387 CB2-PY2333 CB2-PY2334 CB2-PY2335 CB2-PY2336 CB2-PY2338
Emergency Stop (60mm)
CB2-PY9330
Emergency Stop (90mm)
CB2-PY8330
Stay Put
CB2-BD3
Spring Return
CB2-BDR3
Spring Return (R to C)
CB2-BD8
Spring Return (L to C)
CB2-BD7
Type
Part Number
2-Position
Stay Put (All)
CB2-BG4
3-Position
Stay Put (All)
CB2-BG0
3-Position
Key Switches
START
Non-Illuminated Pushbuttons
Flush Momentary
Projecting Momentary
Reset*
Emergency Stop (Red, 40mm)
Color
Part Number
White
CB2-BA1
Black
CB2-BA2
Green
CB2-BA3
Red
CB2-BA4
White
CB2-BL1
Black
CB2-BL2
Green
CB2-BL3
Red
CB2-BL4
Black (Mechanical)
CM2-BA2-RST
Black (Electrical)
CB2-BA2-RST
Style
Part Number
Turn Release
CB2-BS44
Key Release
CB2-BS14
Push/Pull
CB2-BT4
Assemblies for Selector Switches & Pushbuttons
*Mechanical style Reset utilizes CB2-RPX extension shaft and electrical style utilizes CB2-BZ contact block assembly. Contact Block & Collar Additional Contact Blocks (Max 6)
78
www.westcoastpower.com 1-866-955-0888
Contact
Part Number
1 NO
CB2-BZ101
1 NC
CB2-BZ102
2 NO
CB2-BZ103
2 NC
CB2-BZ104
1 NO & 1 NC
CB2-BZ105
1 NO
CB2-BE101
1 NC
CB2-BE102
ACCESSORIES
Complete Stations - Start/Stop Spring Return
Meets UL Type 1, 12, 3R, 4 & 4X Ratings Rugged Design Convenient standard knockouts for easy installation
Description
Part Number
Plastic Control Station
CC2P-215
Metal Control Station
CC2M-215
Compact Pilot Lights Color
Part Number
Green
CB2-B7-IV-73*
Red
CB2-B7-IV-74*
Amber
CB2-B7-IV-78*
* Select Desired Voltage From Table Upon Ordering
Modular LED Pilot Lights (Lens + Assembly)
Lens
Color
Part Number
Green
CB2-BVL03
Red
CB2-BVL04
Yellow
CB2-BVL05
Part Number CB2-BVL73* Assembly
CB2-BVL74* CB2-BVL75*
* Select Desired Voltage From Table Upon Ordering
Voltage Selection Chart
Miscellaneous Accessories Description Fixing Collar
Part Number
AC Voltage
24VAC
110VAC
CB2-B
DC Voltage
12VDC
24VDC
Spare/Replacement Keys
CB2-K455
Padlocking Attachment
CB2-BZ6
Projecting Pushbutton Boot (Clear)
CC-L
Flush Pushbutton Boot (Clear)
CC-S
5.125” plastic shaft (can be trimmed to any length)
240VAC
CB2-RPX
79
INDUSTRIAL CATALOG
DIN Rail Mountable Terminal Blocks 25~230A at 600VAC Accepts Wire Size 22~4/0 AWG Compatible with TS-32 & TS-35 DIN
Specifications
Increases conductivity and prevents corrosion through electrolytic copper conductors Screws and fasteners are made of high carbon steel to withstand higher torque Steel yoke for tight wire connections and anti-vibration Large contact points for reliable connections Optional pre-printed terminal block markers (standard numeric or custom marking available)
Choose between cage inserting (left) or central type (right) jumpers.
DK Series - Screw Clamp Connection Rated Surge Solid Wire (AWG) Voltage (kV)
Stranded Wire (AWG)
Wire Strip Length (in)
22~12
22~12
.39~.47
7
M3
.20 x 1.87 x 2.32
22~10
22~10
.39~.47
7
M3
.24 x 1.87 x 2.32
2.2
20~8
20~8
.31
15.6
M4
.31 x 1.87 x 2.32
2.2
20~6
20~6
.47~.55
15.6
M4
.39 x 1.87 x 2.32
70A
2.2
14~6
14~6
.59~.67
30.4
M5
.47 x 2.50 x 2.32
115A
2.2
12~2
12~2
.63~.71
50
M6
.63 x 2.50 x 2.32
Part Number
Rated Current
DK2.5
25A
2.2
DK4
35A
2.2
DK6
45A
DK10
60A
DK16 DK35
Torque Screw (lb-in)
Dimensions H x W x T (in)
DK50
150A
2.2
6~2(105A)
6~1/0
.98~1.18
50
M6
.79 x 3.02 x 2.78
DK95
230A
2.2
2~4(100A)
2~4/0
1.18~1.34
90
M8
.98 x 3.48 x 3.15
Accessories
Standard numeric terminal block marking (above). Custom marking available by special order.
80
Cross Jumper
Model
End Cover
Partition
End Bracket
2-Pole
3-Pole
DK2.5/GK2.5
DK2.5C
DKSPS-002
SS4
DS2.5-02P
DS2.5-03P
DK4/GK4
DK2.5C
DKSPS-002
SS4
DS4-02P
DS4-03P
Central Type
Cage Inserting 2-Pole
3-Pole
CSC-2.5-02P CSC-2.5-03P CSC-4-02P
CSC-4-03P
Terminal Markers* TM08W TM10W
DK6
DK2.5C
DKSPS-002
SS7
DS6-02P
DS6-03P
CSC-6-02P
CSC-6-03P
TM11W
DK10/GK10
DK2.5C
DKSPS-002
SS7
DS10-02P
DS10-03P
CSC-10-02P
CSC-10-03P
TM12W
DK16/GK16
DK16C
DKSPS-003
SS6
DS16-02P
DS16-03P
DK35
DK16C
DKSPS-003
SS6
DS35-02P
TM13W TM14W
DK50
SS6
TM14W
DK95
SS6
TM14W
* Specify numeric label range or custom values when ordering
www.westcoastpower.com 1-866-955-0888
ACCESSORIES
GK Series - Grounding Terminal Blocks Rated Rated Surge Solid Wire Part Number Current (AWG) Voltage (kV)
Stranded Wire Strip Wire (AWG) Length (in)
Torque (LB-in)
Screw
Dimensions H x W x T (in)
GK2.5
25A
2.2
26~12
26~12
.39~.55
6.9
M3
.22 x 1.83 x 2.20
GK4
35A
2.2
26~10
26~10
.47~.63
6.9
M3
.26 x 1.83 x 2.20
GK10
50A
2.2
16~8
16~8
.47~.63
15.6
M4
.41 x 1.83 x 2.20
GK16
65A
-
14~6
14~6
.55~.71
30.4
M5
.47 x 2.46 x 2.20
SK Series - Spring Clamp Connection End Cover
Part Number
Terminal Markers*
Rated Rated Surge Solid Wire Current Voltage (kV) (AWG)
Stranded Wire Strip Wire (AWG) Length (in)
Dimensions H x W x T (in)
SK4
SK4C
TM10W
20A
2.2
28~12
28~12
.39~.55
1.30 x 2.32 x .24
S4K4
S4K4C
TM10W
20A
2.2
28~12
28~12
.39~.55
1.30 x 3.39 x .24
Miniature Circuit Breakers 1~10A at 460VAC Thermal-magnetic Release 1, 2 & 3-Pole Models
High Value, Supplemental Circuit Breaking
D curve magnetic trip point (10x rated current) provides quick response short circuit protection UL 1077 listed, supplemental overcurrent protection for situations where UL 489 branch protection is already provided or unnecessary Ideal for highly inductive loads or transformers IP20 finger safe design and 35mm DIN-rain mountable
Mini Circuit Breakers - D Curve Magnetic Trip (6kA @ 400VAC) Amps
Part Number
Part Number
Part Number
1
CI-MCB-D/1P-1A
CI-MCB-D/2P-1A
CI-MCB-D/3P-1A
Aux Switch (1 NC) MCB-AUX-1NC
2
CI-MCB-D/1P-2A
CI-MCB-D/2P-2A
CI-MCB-D/3P-2A
Aux Switch (1 NO) MCB-AUX-1NO
3
CI-MCB-D/1P-3A
CI-MCB-D/2P-3A
CI-MCB-D/3P-3A
4
CI-MCB-D/1P-4A
CI-MCB-D/2P-4A
CI-MCB-D/3P-4A
6
CI-MCB-D/1P-6A
CI-MCB-D/2P-6A
10
1-Pole
CI-MCB-D/1P-10A
2-Pole
CI-MCB-D/2P-10A
CI-MCB-D/3P-6A 3-Pole
CI-MCB-D/3P-10A
81
INDUSTRIAL CATALOG
UL Listed Enclosures
Powder Coated or Stainless Steel Finish Quarter Turn Latches on Hinged Doors UL Type 1, 3R, 4, 4X & 12 Available
Standoffs provided for mounting sub-panels Continuous hinged door Black quarter turn latches operated with screwdriver Ground stud on door A NSI-61 gray urethane polyester powder coating
UL Type 1 Hinged Door Enclosures Dimensions (in)
Enclosure Part Number
Weight
H
W
D
(lbs.)
Sub-Panel Part Number
SCE-6N604LP SCE-8N604LP SCE-8N804LP SCE-8N806LP SCE-10N804LP SCE-10N806LP SCE-10N1004LP SCE-10N1006LP SCE-12N1004LP SCE-12N1006LP SCE-12N1204LP SCE-12N1206LP SCE-12N1208LP SCE-14N1204LP SCE-14N1206LP SCE-14N1208LP SCE-16N1206LP SCE-16N1208LP SCE-16N1606LP SCE-16N1608LP SCE-16N2006LP SCE-20N1606LP SCE-20N1608LP SCE-20N2006LP SCE-20N2008LP SCE-20N2010LP SCE-24N1606LP SCE-24N2006LP SCE-24N2008LP SCE-24N2010LP SCE-24N2406LP SCE-24N2408LP SCE-24N2412LP SCE-30N2406LP SCE-30N2408LP SCE-30N2412LP SCE-30N3008LP SCE-36N2406LP SCE-36N2408LP SCE-36N2412LP SCE-36N3006LP SCE-36N3008LP SCE-36N3012LP
6 8 8 8 10 10 10 10 12 12 12 12 12 14 14 14 16 16 16 16 16 20 20 20 20 20 24 24 24 24 24 24 24 30 30 30 30 36 36 36 36 36 36
6 6 8 8 8 8 10 10 10 10 12 12 12 12 12 12 12 12 16 16 20 16 16 20 20 20 16 20 20 20 24 24 24 24 24 24 30 24 24 24 30 30 30
4 4 4 6 4 6 4 6 4 6 4 6 8 4 6 8 6 8 6 8 6 6 8 6 8 10 6 6 8 10 6 8 12 6 8 12 8 6 8 12 6 8 12
2 2 2 2 4 5 4 6 5 8 7 9 12 7 10 13 11 15 16 20 19 19 25 24 31 39 27 28 31 32 40 42 49 51 57 61 60 56 62 73 68 69 83
SCE-6N6MP SCE-8N6MP SCE-8N8MP SCE-8N8MP SCE-10N8MP SCE-10N8MP SCE-10N10MP SCE-10N10MP SCE-12N10MP SCE-12N10MP SCE-12N12MP SCE-12N12MP SCE-12N12MP SCE-14N12MP SCE-14N12MP SCE-14N12MP SCE-16N12MP SCE-16N12MP SCE-16N16MP SCE-16N16MP SCE-20N16MP SCE-20N16MP SCE-20N16MP SCE-20N20MP SCE-20N20MP SCE-20N20MP SCE-24N16MP SCE-24N24MP SCE-24N20MP SCE-24N20MP SCE-24N24MP SCE-24N24MP SCE-24N24MP SCE-30N24MP SCE-30N24MP SCE-30N24MP SCE-30N30MP SCE-36N24MP SCE-36N24MP SCE-36N24MP SCE-36N30MP SCE-36N30MP SCE-36N30MP
Dimensions (in) Weight (lbs.) H W 4 6 6 6 8 8 8 8 10 10 10 10 10 12 12 12 14 14 14 14 18 18 18 18 18 18 22 22 22 22 22 22 22 28 28 28 28 34 34 34 34 34 34
4 4 6 6 6 6 8 8 8 8 10 10 10 10 10 10 10 10 14 14 14 14 14 18 18 18 14 18 18 18 22 22 22 22 22 22 28 22 22 22 28 28 28
*Mounting holes are located 0.75” in from each side and 0.455” from the top and bottom
82
www.westcoastpower.com 1-866-955-0888
1 1 1 1 2 2 3 3 3 3 4 4 4 4 4 4 4 4 4 4 7 7 7 9 9 9 7 11 11 11 11 11 11 13 13 13 20 21 21 21 23 23 23
ENCLOSURES Seams continuously welded and ground smooth Standoffs provided for mounting optional panels Removable stainless steel hinge pins Black quarter turn latches - opens with a screwdriver Ground stud on door and body
Standard mounting hole pattern (1.28” from sides, 0.35” from top/bottom) UL Type 4 enclosures finished with ANSI-61 gray urethane polyester powder coating over .063” carbon steel UL Type 4X enclosures finished with #4 brushed .075” Type 304 stainless steel
UL Type 4/12 & 4X Junction Enclosure Dimensions (in)
Carbon Steel Part Number
Stainless Steel Part Number
Weight
H
W
D
(lbs.)
SCE-604ELJ SCE-606ELJ SCE-806ELJ SCE-8066ELJ SCE-1008ELJ SCE-10086ELJ SCE-1210ELJ SCE-12108ELJ SCE-1212ELJ SCE-1412ELJ SCE-14128ELJ SCE-1614ELJ SCE-16148ELJ SCE-20166ELJ SCE-20168ELJ SCE-20206ELJ SCE-20208ELJ SCE-202010ELJ
SCE-604ELJSS SCE-606ELJSS SCE-806ELJSS SCE-8066ELJSS SCE-1008ELJSS SCE-10086ELJSS SCE-1210ELJSS SCE-12108ELJSS SCE-1212ELJSS SCE-1412ELJSS SCE-14128ELJSS SCE-1614ELJSS SCE-16148ELJSS — — — — —
6 6 8 8 10 10 12 12 12 14 14 16 16 20 20 20 20 20
4 6 6 6 8 8 10 10 12 12 12 14 14 16 16 20 20 20
4 4 4 6 4 6 4 8 6 6 8 6 8 6 8 6 8 10
3 4 4 5 6 8 10 12 11 13 15 16 18 21 23 25 28 31
Sub-Panel Part Number
Dimensions H
W
(lbs.)
SCE-6P4J SCE-6P4J SCE-8P6J SCE-8P6J SCE-10P8J SCE-10P8J SCE-12P10J SCE-12P10J SCE-12P12J SCE-14P12J SCE-14P12J SCE-16P14J SCE-16P14J SCE-20P16J SCE-20P16J SCE-20P20J SCE-20P20J SCE-20P20J
5.25 5.25 7.25 7.25 9.25 9.25 11.25 11.25 11.25 13.25 13.25 15.25 15.25 19.25 19.25 19.25 19.25 19.25
3.25 5.25 5.25 5.25 7.25 7.25 9.25 9.25 11.25 11.25 11.25 13.25 13.25 15.25 15.25 19.25 19.25 19.25
1 1 1 1 2 2 2 2 3 3 3 4 4 5 5 7 7 7
Weight
UL Type 3R Hinged Door Enclosure Dimensions (in)
Enclosure Part Number
H
W
D
SCE-12R1206LP SCE-12R1208LP SCE-16R1206LP SCE-16R1208LP SCE-20R1606LP SCE-20R1608LP SCE-24R2006LP SCE-24R2008LP SCE-24R2012LP SCE-30R2408LP SCE-30R2412LP SCE-36R2408LP SCE-36R2412LP SCE-36R3008LP SCE-36R3012LP SCE-42R3012LP
12 12 16 16 20 20 24 24 24 30 30 36 36 36 36 42
12 12 12 12 16 16 20 20 20 24 24 24 24 30 30 30
6 8 6 8 6 8 6 8 12 8 12 8 12 8 12 12
Weight Sub-Panel (lbs.) Part Number 12 14 16 19 20 25 28 32 35 60 64 62 73 70 85 114
Integrated rain hood ANSI-61 gray urethane polyester powder coating over galvanized steel Hinged door includes gasket
SCE-12DLP12 SCE-12DLP12 SCE-16P12 SCE-16P12 SCE-20P16 SCE-20P16 SCE-24P20 SCE-24P20 SCE-24P20 SCE-30P24 SCE-30P24 SCE-36P24 SCE-36P24 SCE-36P30 SCE-36P30 SCE-42P30
Dimensions
Weight
H
W
(lbs.)
9 9 13 13 17 17 21 21 21 27 27 33 33 33 33 39
9 9 9 9 13 13 17 17 17 21 21 21 21 27 27 27
3 3 4 4 7 7 11 11 11 16 16 22 22 27 27 33
Spot welded construction Black quarter-turn latch with padlocking provision Ground studs on door and body Standoffs provided for mounting optional sub-panels 83
INDUSTRIAL CATALOG
UL Type 4/12 & 4X Single Door Enclosures Powder Coated or Stainless Steel Finish Dust & Oil Resistant Gasket Quarter Turn Latches on Hinged Door
Construction & Specifications
Flange collar around all sides of door opening Removable print pocket Standoffs provided for mounting sub-panels Removable and interchangeable doors Black quarter turn latches operated with screwdriver Ground stud on door and body
Standard mounting holes located 0.75” from edges UL Type 4 enclosures finished with ANSI-61 gray urethane polyester powder coating over .075” carbon steel UL Type 4X enclosures finished with #4 brushed .075” Type 304 stainless steel Optional locking door latches available Additional accessories available
UL Type 4/12 & 4X Enclosures Carbon Steel Part Number SCE-12EL1206LP SCE-12EL2406LP SCE-16EL1206LP SCE-16EL1208LP SCE-16EL1408LP SCE-16EL1606LP SCE-16EL1608LP SCE-16EL2006LP SCE-16EL2008LP SCE-20EL1206LP SCE-20EL1606LP SCE-20EL1608LP — SCE-20EL1612LP SCE-20EL2006LP SCE-20EL2008LP — SCE-20EL2012LP SCE-20EL2408LP SCE-24EL1206LP SCE-24EL1606LP SCE-24EL1608LP SCE-24EL2006LP SCE-24EL2008LP SCE-24EL2010LP SCE-24EL2012LP SCE-24EL2016LP SCE-24EL2406LP SCE-24EL2408LP SCE-24EL2410LP SCE-24EL2412LP
84
Weight (lbs.)
14 28 17 21 20 21 26 27 27 22 24 27 — 41 29 31 — 37 35 24 31 30 42 35 37 52 61 46 43 54 51
Stainless Steel Part Number SCE-12EL1206SSLP SCE-12EL2406SSLP SCE-16EL1206SSLP SCE-16EL1208SSLP — SCE-16EL1606SSLP SCE-16EL1608SSLP — SCE-16EL2008SSLP — SCE-20EL1606SSLP SCE-20EL1608SSLP SCE-20EL1610SSLP — SCE-20EL2006SSLP SCE-20EL2008SSLP SCE-20EL2010SSLP — SCE-20EL2408SSLP — — SCE-24EL1608SSLP SCE-24EL2006SSLP SCE-24EL2008SSLP SCE-24EL2010SSLP SCE-24EL2012SSLP — — SCE-24EL2408SSLP SCE-24EL2410SSLP SCE-24EL2412SSLP
www.westcoastpower.com 1-866-955-0888
Dimensions
Weight (lbs.)
H
W
D
15 24 17 26 — 21 26 — 29 — 29 27 30 — 32 33 42 — 42 — — 32 42 37 48 52 — — 47 54 57
12 12 16 16 16 16 16 16 16 20 20 20 20 20 20 20 20 20 20 24 24 24 24 24 24 24 24 24 24 24 24
12 24 12 12 14 16 16 20 20 12 16 16 16 16 20 20 20 20 24 12 16 16 20 20 20 20 20 24 24 24 24
6 6 6 8 8 6 8 6 8 6 6 8 10 12 6 8 10 12 8 6 6 8 6 8 10 12 16 6 8 10 12
Sub-Panel Part Number SCE-12DLP12 SCE-12P24 SCE-16P12 SCE-16P12 SCE-16DLP14 SCE-16P16 SCE-16P16 SCE-20P16 SCE-20P16 SCE-20P12 SCE-20P16 SCE-20P16 SCE-20P16 SCE-20P16 SCE-20P20 SCE-20P20 SCE-24P20 SCE-20P20 SCE-24P20 SCE-12P24 SCE-24P16 SCE-24P16 SCE-24P20 SCE-24P20 SCE-24P20 SCE-24P20 SCE-24P20 SCE-24P24 SCE-24P24 SCE-24P24 SCE-24P24
Dimensions
Weight
H
W
(lbs.)
9 9 13 13 13 13 13 17 17 17 17 17 17 17 17 17 21 17 21 9 21 21 21 21 21 21 21 21 21 21 21
9 21 9 9 11 13 13 13 13 9 13 13 13 13 17 17 17 17 17 21 13 13 17 17 17 17 17 21 21 21 21
3 5 4 4 4 5 5 7 7 5 7 7 7 7 10 10 11 10 11 5 9 9 11 11 11 11 11 14 14 14 14
ENCLOSURES
Carbon Steel Part Number SCE-24EL2416LP SCE-24EL3008LP SCE-24EL3010LP SCE-30EL1606LP SCE-30EL2008LP SCE-30EL2010LP SCE-30EL2408LP SCE-30EL2410LP SCE-30EL2412LP SCE-30EL2416LP SCE-30EL2420LP SCE-30EL2424LP SCE-30EL3008LP SCE-30EL3010LP SCE-30EL3012LP SCE-30EL3608LP SCE-36EL2408LP SCE-36EL2410LP SCE-36EL2412LP SCE-36EL2416LP SCE-36EL3008LP SCE-36EL3010LP SCE-36EL3012LP SCE-36EL3016LP SCE-36EL3020LP SCE-36EL3608LP SCE-36EL3612LP SCE-36EL3616LP SCE-40EL2412LP SCE-42EL2410LP SCE-42EL3008LP SCE-42EL3010LP SCE-42EL3012LP SCE-42EL3016LP SCE-42EL3608LP SCE-42EL3610LP SCE-42EL3612LP SCE-42EL3616LP SCE-48EL2408LP SCE-48EL2412LP SCE-48EL3010LP SCE-48EL3016LP SCE-48EL3608LP SCE-48EL3610LP SCE-48EL3612LP SCE-48EL3616LP SCE-48EL3620LP SCE-60EL2412LP SCE-60EL3610LP SCE-60EL3612LP SCE-60EL3616LP SCE-60EL3620LP SCE-72EL3012LP SCE-72EL3016LP SCE-72EL3024LP SCE-72EL3612LP SCE-72EL3616LP
Weight (lbs.)
71 53 63 42 47 50 55 68 63 80 91 99 63 82 82 84 64 74 77 82 73 89 87 114 123 102 111 122 89 79 101 105 111 117 117 127 123 149 83 99 117 151 129 137 133 149 173 141 164 162 195 209 217 236 242 222 234
Stainless Steel Part Number SCE-24EL2416SSLP SCE-24EL3008SSLP SCE-24EL3010SSLP SCE-30EL1606SSLP SCE-30EL2008SSLP SCE-30EL2010SSLP SCE-30EL2408SSLP SCE-30EL2410SSLP SCE-30EL2412SSLP SCE-30EL2416SSLP — — SCE-30EL3008SSLP SCE-30EL3010SSLP SCE-30EL3012SSLP SCE-30EL3608SSLP SCE-36EL2408SSLP SCE-36EL2410SSLP — — SCE-36EL3008SSLP SCE-36EL3010SSLP SCE-36EL3012SSLP — — SCE-36EL3608SSLP SCE-36EL3612SSLP — — SCE-42EL2410SSLP — SCE-42EL3010SSLP — — — — SCE-42EL3612SSLP SCE-42EL3616SSLP — — — — — — SCE-48EL3612SSLP SCE-48EL3616SSLP — — — SCE-60EL3612SSLP SCE-60EL3616SSLP — — SCE-72EL3016SSLP — SCE-72EL3612SSLP SCE-72EL3616SSLP
Dimensions
Weight (lbs.)
H
W
D
Sub-Panel Part Number
72 58 64 42 52 57 53 68 69 80 — — 67 81 89 84 66 74 — — 75 89 94 — — 102 111 — — 84 — 105 — — — — 124 149 — — — — — — 131 153 — — — 162 195 — — 236 — 222 234
24 24 24 30 30 30 30 3 30 30 30 30 30 30 30 30 36 36 36 36 36 36 36 36 36 36 36 36 40 42 42 42 42 42 42 42 42 42 48 48 48 48 48 48 48 48 48 60 60 60 60 60 72 72 72 72 72
24 30 30 16 20 20 24 24 24 24 24 24 30 30 30 36 24 24 24 24 30 30 30 30 30 36 36 36 24 24 30 30 30 30 36 36 36 36 24 24 30 30 36 36 36 36 36 24 36 36 36 36 30 30 30 36 36
16 8 10 6 8 10 8 10 12 16 20 24 8 10 12 8 8 10 12 16 8 10 12 16 20 8 12 16 12 10 8 10 12 16 8 10 12 16 8 12 10 16 8 12 10 16 20 12 10 12 16 20 12 16 24 12 16
SCE-24P24 SCE-30P24 SCE-30P24 SCE-30P16 SCE-30P20 SCE-30P20 SCE-30P24 SCE-30P24 SCE-30P24 SCE-30P24 SCE-30P24 SCE-30P24 SCE-30P30 SCE-30P30 SCE-30P30 SCE-36P30 SCE-36P24 SCE-36P24 SCE-36P24 SCE-36P24 SCE-36P30 SCE-36P30 SCE-36P30 SCE-36P30 SCE-36P30 SCE-36P36 SCE-36P36 SCE-36P36 SCE-40P24 SCE-42P24 SCE-42P30 SCE-42P30 SCE-42P30 SCE-42P30 SCE-42P36 SCE-42P36 SCE-42P36 SCE-42P36 SCE-48P24 SCE-48P24 SCE-48P30 SCE-48P30 SCE-48P36 SCE-48P36 SCE-48P36 SCE-48P36 SCE-48P36 SCE-60P24 SCE-60P36 SCE-60P36 SCE-60P36 SCE-60P36 SCE-72P30 SCE-72P30 SCE-72P30 SCE-72P36 SCE-72P36
Dimensions
Weight
H
W
(lbs.)
21 27 27 27 27 27 27 27 27 27 27 27 27 27 27 33 33 33 33 33 33 33 33 33 33 33 33 33 37 39 39 39 39 39 39 39 39 39 45 45 45 45 45 45 45 45 45 57 57 57 57 57 69 69 69 69 69
21 21 21 13 17 17 21 21 21 21 21 21 27 27 27 27 21 21 21 21 27 27 27 27 27 33 33 33 21 21 27 27 27 27 33 33 33 33 21 21 27 27 33 33 33 33 33 21 33 33 33 33 27 27 27 33 33
14 16 16 12 16 16 16 16 16 16 16 16 24 24 24 27 22 22 22 22 27 27 27 27 27 35 35 35 40 33 33 33 33 33 39 39 39 39 31 31 39 39 46 46 46 46 46 50 58 58 58 58 71 71 71 74 74
*Mounting holes are located .75” in from each side, top and bottom.
85
INDUSTRIAL CATALOG
UL Type 4X Fiberglass Enclosures Reinforced Polyester Construction Gasketed & Sealed for Outdoor Use Hinged Screw Cover
Solid Construction for Rugged Applications
esigned for high temperature or corrosive environments D Protects components from dirt, dust, oil and water Compression molded fiberglass reinforced polyester is UV stabilized for outdoor use Stainless steel hardware Hinged door seals with neoprene gasket Standard mounting flanges keep installation hardware outside of sealed enclosure
Standards
86
L 508 and UL 50 listed (Type 1, 2, 3, 3R, 4, 4X, 12, 13) U CSA Certified Light gray color (RAL 7035) Flammability rating meets UL 508 Joint Industrial Council (JIC) enclosure sizing
Dimensions (in)
Enclosure Part Number
H
W
D
AMU664HF AMU864HF AMU1084HF AMU1206HF AMU1426HF AMU1648HF AMU1860HF AMU2060HF
6.05 8.05 10.05 12.05 14.05 16.05 18.05 20.05
6.27 6.27 8.27 10.27 12.27 14.27 16.27 16.27
4.13 4.13 4.13 6.13 6.13 8.13 10.13 10.13
www.westcoastpower.com 1-866-955-0888
Sub-Panel Part Number P66 P86 P108 P1210 P1412 P1614 P1816 P2016
Additional options and configurations available through special order. Enclosure shown above with clear poly-carbonate window.
Panel Dimensions (in) H
W
4.81 6.75 8.75 10.75 12.75 14.75 16.88 18.44
4.81 4.88 6.88 8.88 10.88 12.88 14.88 14.44
REFERENCE
Enclosure Standards NEMA and UL are standard writing organizations that are commonly recognized in North America. Their ratings are based on similar application descriptions and expected performance. UL requires enclosure testing by a qualified evaluator. Site inspectors check manufacturing practices to ensure adherence to methods and materials utilized. NEMA standards do not require independent testing and allows manufacturers to enforce their own compliance measures.
Enclosure Rating
NEMA Specification
UL Specification
Type 1
Enclosures are intended for indoor use primarily to provide a degree of protection against contact with the enclosed equipment or locations where unusual service conditions do not exist.
Indoor use primarily to provide protection against contact with the enclosed equipment and against a limited amount of falling dirt.
Type 3R
Enclosures are intended for outdoor use primarily to provide a degree of protection against falling rain and sleet; undamaged by the formation of ice on the enclosure.
Outdoor use to provide a degree of protection against falling rain; undamaged by the formation of ice on the enclosure.
Enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against windblown dust and rain, splashing water; and hose directed water; undamaged by the formation of ice on the enclosure.
Either indoor or outdoor use to provide a degree of protection against falling rain, splashing water, and hose-directed water; undamaged by the formation of ice on the enclosure.
Enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against corrosion, windblown dust and rain, splashing water, and hose-directed water; undamaged by the formation of ice on the enclosure.
Either indoor or outdoor use to provide a degree of protection against falling rain, splashing water, and hosedirected water; undamaged by the formation of ice on the enclosure; resists corrosion.
Enclosures are intended for indoor use primarily to provide a degree of protection against dust, falling dirt, and dripping noncorrosive liquids.
Indoor use to provide a degree of protection against dust, dirt, fiber flyings, dripping water, and external condensation of noncorrosive liquids.
This material is reproduced with permission from NEMA. The preceding descriptions, however are not intended to be complete representations of the National Electrical Manufacturers Association standards for enclosures.
This material is reproduced with permission from Underwriters Laboratories, Inc. Enclosures for Electrical Equipment, UL 50, Copyright 1995 and Industrial Control Equipment, UL 508, Copyright 1996 by Underwriters Laboratories Inc.
Type 4
Type 4X
Type 12
Underwriters Laboratories Inc. (UL) shall not be responsible for the use of or reliance upon a UL Standard by anyone. UL shall not incur any obligation or liability for damages, including consequential damages, arising out of or connection with the use, interpretation of, or reliance upon a UL Standard.
87
INDUSTRIAL CATALOG
UL Sizing Chart (1 Phase) HP
Volts
1/10 1/8 1/6 1/4 1/3 1/2 3/4 1 1 1/2 2 3 5 7 1/2 10 15
120 230 120 230 120 230 120 230 120 230 120 230 120 230 120 230 120 230 120 230 120 230 120 230 120 230 120 230 120 230
Cerus Motor Overload
Bend Motor Wire Size Radius* Amps (AWG) (Inches)
Contactor
3.0 1.5 3.8 1.9 4.4 2.2 5.8 2.9 7.2 3.6 9.8 4.9 13.8 6.9 16.0 8.0 20.0 10.0 24.0 12.0 34.0 17.0 56.0 28.0 80.0 40.0 100.0 50.0 135.0 68.0
MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-12 MRC-9 MRC-18 MRC-9 MRC-18 MRC-9 MRC-25 MRC-12 MRC-25 MRC-18 MRC-40 MRC-18 MRC-63 MRC-32 MRC-85 MRC-40 CRC-100 MRC-63 CRC-150 CRC-75
12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 10 12 8 12 6 10 4 8 3 8 1/0 4
1.5 2 3 1.5 3 1.5 5 2
Thermal MTK-32/3-4 MTK-32/3-1.6 MTK-32/3-4 MTK-32/3-2.5 MTK-32/3-6 MTK-32/3-2.5 MTK-32/3-8 MTK-32/3-4 MTK-32/3-8 MTK-32/3-4 MTK-32/3-13 MTK-32/3-6 MTK-32/3-18 MTK-32/3-8 MTK-32/3-18 MTK-32/3-9 MTK-32/3-25 MTK-32/3-13 MTK-32/3-25 MTK-32/3-13 MTK-63/3-40 MTK-32/3-22 MTK-63/3-65 MTK-32/3-32 MTK-95/3-85 MTK-63/3-50 CTK-100/3-125A MTK-63/3-65 CTK-150/3-150 CTK-85/3-75
Electronic
Manual Motor Starter
Motor Circuit Protector
CRP22-3P 5A CRP22-3P 5A CRP22-3P 5A CRP22-3P 5A CRP22-3P 5A CRP22-3P 5A CRP22-3S 22A CRP22-3P 5A CRP22-3S 22A CRP22-3P 5A CRP22-3S 22A CRP22-3S 22A CRP22-3S 22A CRP22-3S 22A CRP22-3S 22A CRP22-3S 22A CRP22-3S 22A CRP22-3S 22A CRP40-3S 40A CRP22-3S 22A CRP40-3S 40A CRP22-3S 22A CRP80-3S 80A CRP40-3S 40A CRP80-3S 80A CRP80-3S 80A CRP80-3S-80A
CMS-32HI-4 CMS-32HI-1.6 CMS-32HI-4 CMS-32HI-2.5 CMS-32HI-6 CMS-32HI-2.5 CMS-32HI-8 CMS-32HI-4 CMS-32HI-8 CMS-32HI-4 CMS-32HI-13 CMS-32HI-6 CMS-32HI-17 CMS-32HI-8 CMS-32HI-17 CMS-32HI-10 CMS-32HI-22 CMS-32HI-13 CMS-32HI-26 CMS-32HI-13 CMS-63HI-40 CMS-32HI-22 CMS-63HI-63 CMS-32HI-32 CMS-100HI-90 CMS-63HI-50 CMS-63HI-63 CMS-100H-75
CMS-32HI-4 CMS-32HI-1.6 CMS-32HI-4 CMS-32HI-2.5 CMS-32HI-6 CMS-32HI-2.5 CMS-32HI-6 CMS-32HI-4 CMS-32HI-8 CMS-32HI-4 CMS-32HI-10 CMS-32HI-6 CMS-32HI-17 CMS-32HI-8 CMS-32HI-17 CMS-32HI-8 CMS-32HI-22 CMS-32HI-10 CMS-32HI-26 CMS-32HI-13 CMS-63HI-40 CMS-32HI-17 CMS-63HI-63 CMS-32HI-32 CMS-100HI-90 CMS-63HI-40 CMS-100HI-100 CMS-63HI-50 CMS-100HI-75
Motor Engineering Formulas Legend E = Volts I = Amps W = Watts PF = Power Factor Eff = Efficiency HP = Horsepower 1HP = 746 Watts
AC/DC Formulas Single Phase
Three Phase
Amps when HP is known
To Find
HP x 746 E x Eff
HP x 746 E x Eff x PF
HP x 746 1.73 x E x Eff x PF
Amps when kW is known
kW x 1000 E
kW x 1000 E x PF
kW x 1000 1.73 x E x PF
Amps when kVA is known
-
kVA x 1000 E
kVA x 1000 1.73 x E
Ex I
IxE 1000
I x E x PF 1000
I x E x 1.73 x PF 1000
P R
-
IxE 1000
I x E x 1.73 1000
I x E x Eff 746
I x E x Eff x PF 746
I x E x Eff x 1.73 x PF 746
Kilowatts Kilovolt (Amps) Horsepower (Output)
AC Efficiency & Power Factor Formulas To Find Efficiency Power Factor
88
Single Phase
Three Phase
746 x HP E x I x PF
746 x HP E x I x PF x 1.732
Input Watts VxA
Input Watts E x I x PF x 1.732
www.westcoastpower.com 1-866-955-0888
Ohm’s Law E2 I2 x R R
P E
IxR
P I
P E I R E R
P I2
PxR
E2 P
E I
Motor Application Formulas Horsepower = Torque (lb-ft) x RPM 5252 Torque (lb-ft) = Horsepower x 5252 RPM
REFERENCE
UL Sizing Chart (3 Phase) HP
1/2
3/4
1
1 1/2
2
3
5
7 1/2
10
15
20
25
30
40
50
60
75
100
125
150
Volts 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480 208 230 480
Bend Motor Wire Size Radius Amps (AWG) (Inches) 2.4 2.2 1.1 3.5 3.2 1.6 4.6 4.2 2.1 6.6 6.0 3.0 7.5 6.8 3.4 10.5 9.6 4.8 16.7 15.2 7.6 24.0 22.0 11.0 31.0 28.0 14.0 46.0 42.0 21.0 59.0 54.0 27.0 75.0 68.0 34.0 88.0 80.0 40.0 114.4 104.0 52.0 143.0 130.0 65.0 169.4 154.0 77.0 211.2 192.0 96.0 272.8 248.0 124.0 343.2 312.0 156.0 396.0 360.0 180.0
12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 10 10 12 8 10 12 8 8 10 6 6 10 4 4 8 3 4 8 2 2 6 1/0 1 6 2/0 2/0 4 4/0 3/0 3 2 x 1/0 2 x 1/0 1 2 x 2/0 2 x 2/0 2/0 2 x 3/0 2 x 3/0 3/0
1.5 1.5 1.5 1.5 2 2 2 2 1.5 2.5 2 1.5 5 3 1.5 7 6 2 7 7 2 10 8 3 12 12 6 14 14 7 8* 7* 7
Cerus Motor Overload Contactor MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-9 MRC-12 MRC-12 MRC-9 MRC-18 MRC-18 MRC-9 MRC-25 MRC-25 MRC-12 MRC-35 MRC-32 MRC-18 MRC-50 MRC-50 MRC-25 MRC-63 MRC-63 MRC-32 MRC-75 MRC-75 MRC-35 MRC-95 MRC-85 MRC-50 CRC-125 CRC-125 MRC-63 CRC-180 CRC-150 MRC-75 CRC-180 CRC-180 MRC-85 CRC-300 CRC-220 CRC-125 CRC-300 CRC-300 CRC-150 CRC-400 CRC-400 CRC-180 CRC-600 CRC-400 CRC-220
Thermal MTK-32/3-2.5 MTK-32/3-2.5 MTK-32/3-1.6 MTK-32/3-4 MTK-32/3-4 MTK-32/3-1.6 MTK-32/3-6 MTK-32/3-6 MTK-32/3-2.5 MTK-32/3-8 MTK-32/3-8 MTK-32/3-4 MTK-32/3-9 MTK-32/3-9 MTK-32/3-4 MTK-32/3-13 MTK-32/3-13 MTK-32/3-6 MTK-32/3-18 MTK-32/3-18 MTK-32/3-9 MTK-32/3-25 MTK-32/3-25 MTK-32/3-13 MTK-63/3-36 MTK-32/3-32 MTK-32/3-18 MTK-63/3-50 MTK-63/3-50 MTK-32/3-25 MTK-63/3-65 MTK-63/3-65 MTK-32/3-32 MTK-95/3-85 MTK-95/3-75 MTK-63/3-40 MTK-95/3-95 MTK-95/3-85 MTK-63/3-50 CTK-100/3-125A CTK-100/3-125A MTK-63/3-65 CTK-220/3-180A CTK-150/3-150A MTK-95/3-75 CTK-220/3-180A CTK-220/3-180A MTK-95/3-85 CTK-400/3-240A CTK-220/3-240A CTK-100/3-125A CTK-400/3-300A CTK-400/3-300A CTK-150/3-150A CTK-400/3-400A CTK-400/3-400A CTK-220/3-180A CTK-600/3-400A CTK-400/3-400A CTK-220/3-240A
Electronic
Manual Motor Starter
Motor Circuit Protector*
CRP22-3P 5A CRP22-3P 5A CRP22-3S 1.5A CRP22-3P 5A CRP22-3P 5A CRP22-3P 5A CRP22-3P 5A CRP22-3P 5A CRP22-3P 5A CRP22-3S 22A CRP22-3S 22A CRP22-3P 5A CRP22-3S 22A CRP22-3S 22A CRP22-3P 5A CRP22-3S 22A CRP22-3S 22A CRP22-3P 5A CRP22-3S 22A CRP22-3S 22A CRP22-3S 22A CRP40-3S 40A CRP40-3S 40A CRP22-3S 22A CRP40-3S 40A CRP40-3S 40A CRP22-3S 22A CRP80-3S 80A CRP80-3S 80A CRP40-3S 40A CRP80-3S 80A CRP80-3S 80A CRP40-3S 40A CRP80-3S 80A CRP80-3S 80A CRP40-3S 40A CRP80-3S 80A CRP80-3S 80A CRP80-3S 80A CRP80-3S 80A -
CMS-32HI-2.5 CMS-32HI-2.5 CMS-32HI-1.6 CMS-32HI-4 CMS-32HI-4 CMS-32HI-1.6 CMS-32HI-6 CMS-32HI-6 CMS-32HI-2.5 CMS-32HI-8 CMS-32HI-8 CMS-32HI-4 CMS-32HI-8 CMS-32HI-8 CMS-32HI-4 CMS-32HI-13 CMS-32HI-13 CMS-32HI-6 CMS-32HI-22 CMS-32HI-17 CMS-32HI-10 CMS-32HI-26 CMS-32HI-26 CMS-32HI-13 CMS-63HI-40 CMS-32HI-32 CMS-63HI-50 CMS-63HI-50 CMS-32HI-26 CMS-63HI-63 CMS-63HI-63 CMS-32HI-32 CMS-100HI-90 CMS-100HI-75 CMS-63HI-40 CMS-100HI-100 CMS-100HI-90 CMS-63HI-50 CMS-63S/H-50 CMS-63HI-63 CMS-100HI-75 CMS-100HI-90 CMS-100HI-100 -
CMS-32HI-2.5 CMS-32HI-2.5 CMS-32HI-1.6 CMS-32HI-4 CMS-32HI-4 CMS-32HI-1.6 CMS-32HI-6 CMS-32HI-6 CMS-32HI-2.5 CMS-32HI-8 CMS-32HI-8 CMS-32HI-4 CMS-32HI-8 CMS-32HI-8 CMS-32HI-4 CMS-32HI-13 CMS-32HI-10 CMS-32HI-6 CMS-32HI-22 CMS-32HI-17 CMS-32HI-8 CMS-32HI-26 CMS-32HI-26 CMS-32HI-13 CMS-63HI-40 CMS-32HI-32 CMS-32HI-17 CMS-63HI-50 CMS-63HI-50 CMS-32HI-26 CMS-63HI-63 CMS-63HI-63 CMS-32HI-32 CMS-100HI-90 CMS-100HI-75 CMS-63HI-40 CMS-100HI-100 CMS-100HI-90 CMS-63HI-50 TS250NU ATU 250 250A TS250NU ATU 250 250A CMS-63HI-63 TS400NU ATU 400 400A TS400NU ATU 400 300A CMS-100HI-75 TS400NU ATU 400 400A TS400NU ATU 400 400A CMS-100HI-90 TS800NU ATU 800 500A TS800NU ATU 800 500A CMS-100HI-100 TS800NU ATU 800 600A TS400NU ATU 400 300A TS800NU ATU 800 800A TS800NU ATU 800 800A TS400NU ATU 400 400A TS400NU ATU 400 400A
* Field wiring requires two conductors
91 89
1550 Montague Expressway San Jose, CA 95131
CERUS INDUSTRIAL 2009
Check out our NEW Pump Products on Page 46!