IRON
Opening / Closing Time* Opening / Closing Cycles per Hour HP End-of-stroke system Reduction ratio Threaded bar diameter Rail length
14 seconds 20 1/4 Encoder 1:26 1/2” 1.5 and 2 m *1.5-meter rail.
LEVANTE
Opening / Closing Time* Opening / Closing Cycles per Hour HP End-of-stroke system Reduction ratio Threaded bar diameter Rail length
Levante
Levante Levante SP Jet Flex
14 seconds 20 1/4 Encoder / ILS** 1:26 1/2” 1.4 up to 2 m
8 seconds 20 1/4 Encoder 2:26 1/2” 1.5 m
4 seconds 20 1/4 Encoder 2:26 1/2” 1.5 up to 3 m *1.5-meter rail; **Inductive Limit Switch.
NEW LEVANTE New design
POTENZA
Opening / Closing Time* Opening / Closing Cycles per Hour HP End-of-stroke system Reduction ratio Threaded bar diameter Rail length
Potenza
Potenza Potenza SP Jet Flex
14 seconds 30 1/3 Encoder / ILS** 1:26 1/2” 1.4 up to 4.5 m
8 seconds 30 1/3 Encoder 2:26 1/2” 1.5 up to 2 m
4 seconds 30 1/3 Encoder 2:26 1/2” 1.5 up to 3 m *1.5-meter rail; **Inductive Limit Switch.
CONTATTO
Cell phone-activated receiver
-Storage Capacity: 1024 telephone numbers; - Two settable outputs (pulse / retention); - Two inputs; - Sending of SMS to five distinct telephone numbers; - Outputs activated by Free Call; - PC communication by USB cable; - Real-time event monitoring; - Event history stored on a database.
MATRIX PRO ProxCard Reader - Storing capacity: up to 999 ProxCards and 999 user codes. Each user code is linked to a ProXCard, i.e., both are stored on the same specific memory cluster; - Inputs to Two ProxCard Readers; - Sequential or addressable storage of remote controls / user codes; - Four-digit, seven-segment display; - Numeric / function keypad; - Three stand-alone outputs with solid state relay (SSR); - Outputs settable as pulse (NO / NC), retention, timed (NO / NC) and panic (NO / NC); - Erases each remote control at a time (sequentially or by address) or all remote controls at once; - Blocking and unblocking of remote controls / user codes, without erasing them;
- Fifteen setting groups which can be used to define permissions of access to specific users; - Master code, used for programming (can be changed anytime); - Compatible to Transfer, with five positions on the memory available to backup of ProxCards and user codes, as well as to settings backup.
PENTA
Opening / Closing Time* Opening / Closing Cycles per Hour HP End-of-stroke system Reduction ratio Threaded bar diameter Rail length
Penta
Penta 1/3
14 seconds 60 1/2 Encoder / ILS** 1:26 5/8” 1.5 and 4.5 m
14 seconds 60 1/3 Encoder / ILS** 1:26 5/8” 1.5 up to 4.5 m
Penta Penta Penta SP SP 1/3 Jet Flex 8 seconds 60 1/2 Encoder 2:26 5/8” 1.5 up to 4 m
8 seconds 60 1/3 Encoder 2:26 5/8” 1.5 up to 4 m
4 seconds 60 1/2 Encoder 2:26 5/8” 1.5 up to 4.5 m
*1.5-meter rail; **Inductive Limit Switch.
BV CONDOMINIUM Opening / Closing Time* Opening / Closing Cycles per Hour HP End-of-stroke system Reduction ratio Threaded bar diameter Rail length
4.5 seconds Heavy-Duty 1/2 Encoder 2:26 5/8” 1.5 up to 3 m *1.5-meter rail
TORSION Opening / Closing Time Opening / Closing Cycles per Hour HP Reduction ratio
BH
12 seconds 60 1/2 1:800
BH Rio BH Opening / Closing Time* Opening / Closing Cycles per Hour HP End-of-stroke system Reduction ratio Threaded bar diameter Rail length
18 seconds 20 1/4 Encoder 2:30 1/2” 2 up to 3 m
18 seconds 60 1/2 ILS** 2:30 5/8” 2 up to 3 m
NEW PENTA New design
*1.5-meter rail; **Inductive Limit Switch.
MATRIX
CP-1000
Remote control Receiver
Access Control System
- Storing capacity: up to 999 remote controls and 999 user codes. - Fifteen setting groups which can be used to define permissions of access to specific Each memory cluster can store a remote control and / or a user users; code; - Master code, used for programming (can be - Addressable or sequential recording of remote controls / user changed anytime); codes; - Compatibility to four-button remote control. - Four-digit, seven-segment display; - Numeric / function keypad; - Three stand-alone outputs with solid state relay (SSR); - Outputs settable as pulse (NO / NC), retention, timed (NO / NC) and panic (NO / NC); - Erases each remote control at a time (sequentially or at random) or all remote controls at once; - Blocking and unblocking of remote controls / user codes, without erasing them;
- Storing capacity: 1000 user codes (One ProxCard and one remote control per user); - Connection capacity: - Four remote control receivers (each one with four outputs); - Twelve ProxCard readers; - Four relay modules (each one with four outputs). - Eight settable command inputs; - Storage of up to 1200 events on its memory; - Events shown on display; - PC connection via specific software; - Compatible to PS2 keyboard; - Blocking and unblocking of remote controls or ProxCards, without erasing them from memory; - ‘Guard System’ – used to monitor the presence of doorkeepers and watchmen.
‘FACILITY’ LINE FACILITY
‘TOP’ LINE TOP LIGHT
FACILITY 3 TRIMPOTS
- Programming via remote control; - Storage capacity: up to 160 Remote Controls; - End-of-stroke system: Inductive Limit Switch / Encoder; - Courtesy light module, electromagnetic lock module and warning light module outputs: - Input Accessories: - Push Button; - External receiver; - Photocells.
- Programming via trimmer: - Automatic timed closing; - Strength adjustment; - Deceleration adjustment; - Storing capacity: 170 remote controls; - End-of-stroke system: Inductive Limit Switch; - Input Accessories: - External receiver; - Push Button; - Photocells. - Output Accessories: - Courtesy light; - Electromagnetic lock.
- Programming via DIP Switch: - Storing capacity: 160 remote controls; - End-of-stroke system: Inductive Limit Switch / Encoder / ‘Hybrid’; - Courtesy light output; - Input Accessories: - Push Button; - Photocells.
TOP 4 TRIMPOTS
TOP
- Programming via DIP Switch: - Storing capacity: 160 remote controls; - End-of-stroke system: Inductive Limit Switch / Encoder / ‘Hybrid’; - Output Accessories: - Courtesy light; - Electromagnetic lock; - Warning light. - Input Accessories: - External receiver; - Push Button; - Photocells; - RS 485 communication device.
TRIFLEX - Adjustable speed; - End-of-stroke system: Inductive Limit Switch / Encoder / ‘Hybrid’; - Programming via DIP Switch: - Output Accessories: - Courtesy light; - Electromagnetic lock; - Input Accessories: - External receiver; - Push Button; - Photocells.
- Programming via trimmer: - Brake setting; - Strength setting; - Automatic timed closing; - Opening / Closing time. - Storing capacity: 1000 remote controls; - End-of-stroke system: Inductive Limit Switch;
- Input Accessories: - External receiver; - Push Button; - Opening command; - Closing command; - Photocells. - Output Accessories: - Electromagnetic lock; - Courtesy light; - Warning light.
ACESSO PRO
- Wireless control access keypad; it can also be used to activate alarm systems, door and gate openers, automatic barriers and electromagnetic locks; - Code Learning; - 433.92 MHz operating frequency band (Crystal oscillator and Phase-Locked Loop – PLL) - Lithium battery; - 9 or 12-volt power supply*: - Nine user codes and one Master code; - 1 PGM output with negative signal; - The periods of time the device keeps active are individually set.
- Prox card reader, used both to control access to restrict areas and to run sliding glass doors openers, gate openers and electric locks; - Self-learning rolling code; - Frequency: 433.92; - 12-volt power supply*: - Storing capacity: 100 ProxCards (99 user cards and 1 master card).
TOK
PICCOLO
*Not provided.
ACESSO
ALCANCE - Receiver used on PPA gate and sliding glass door openers; - Increases the remote controls storage capacity; - Easy installation; - Available on 292 and 433.92 MHz SAW.
MINI
GOOD LIGHT
- Reinforced grip; - Buttons embedded on the cover; - Exclusive battery holding system; - Circuit board with surface-mount components; - Resistant to falls and impacts; - Available on 292 MHz, 433.92 MHz and 433.92 MHz SAW.
- Device to activate gate / door openers by using the car’s headlight; - In order to open or close the gate, one must only activate the headlight high beam; - 12-V Power Supply; - Protection against power supply polarity inversion; - 433.92 MHz Transmission Frequency; - SAW-locked circuit.
- Four stand-alone buttons; - Increased stability of the signal to a better radio range; - Increased resistance to falls and impacts; - Used to activate alarm systems, as well as automatic gate and door openers; - 433,92 MHz SAW.
RELAY MODULE
PUSHBUTTON MODULE
Automatic gate openers - Alarm systems - Automatic door openers Automatic Barriers - Electric Motors Additional info on WWW.PPA.COM.BR .com/grupoppa |
The images contained on this catalog are merely representational and illustrative and are not intended to reflect actual views from any particular product. PPA reserves the right to change its products, as well as specifications and features, at its sole discretion without prior notice. Accessories sold apart. To a correct installation and use, always refer to the product technical manual, available on the website www.ppa.com.br Only a person trained by PPA must perform installation, maintenance and support services on the equipments.
ELECTRONIC CONTROL UNITIES