PPA Sliding gate openers Catalog - 2011

Page 1


CROSS Cross Custom Cross Opening / Closing Time* Opening / Closing Cycles per Hour Gate weight HP End-of-stroke system Reduction ratio Pinion

12 seconds 30 500 kg 1/4 Encoder / ILS** 1:24 Z14 (aluminum)

12 seconds 30 300 kg 1/5 Encoder / ILS** 1:24 Z14 (aluminum)

*Three-meter-long (9.84 ft) gates; **Inductive Limit Switch.

Opening / Closing Time* Opening / Closing Cycles per Hour Gate weight HP End-of-stroke system Reduction ratio Pinion

Cross SP

Cross Jet Flex Cross 1/3

Cross 1/3 SP

Cross 1/2 Jet Flex

9 seconds 30 300 kg 1/4 ‘Hybrid’ 2:30 Z14 (aluminum)

4.5 seconds 60 600 kg 1/3 ‘Hybrid’ 2:30 Z14 (aluminum)

9 seconds 30 500 kg 1/3 ‘Hybrid’ 1:24 Z14 (aluminum)

4.5 seconds 1/2 ‘Hybrid’ 1:24 Z14 (aluminum)

12 seconds 40 800 kg 1/3 Encoder / ILS** 1:24 Z14 (aluminum)

*Three-meter-long (9.84 ft) gates; **Inductive Limit Switch.

CARRERA

NEW HOME Opening / Closing Time* Opening / Closing Cycles per Hour Gate weight HP End-of-stroke system Reduction ratio Pinion

Opening / Closing Time* Opening / Closing Cycles per Hour Gate weight HP End-of-stroke system Reduction ratio Pinion

13 seconds 20 300 kg 1/4 Encoder / ILS** 1:22 Z14 (Nylon)

6 seconds 60 600 kg 1/3 ‘Hybrid’ 1:30 Z18 (aluminum)

*Three-meter-long (9.84 ft) gates.

*Three-meter-long (9.84 ft) gates; **Inductive Limit Switch.

EURUS Eurus Custom Eurus Custom Eurus 20 Jet Flex Opening / Closing Time* Opening / Closing Cycles per Hour Gate weight HP End-of-stroke system Reduction ratio Pinion

14 seconds 20 300 kg 1/4 Encoder / ILS** 1:30 Z18 (aluminum)

6 seconds 20 300 kg 1/4 ‘Hybrid’ 1:30 Z18 (aluminum)

14 seconds 30 400 kg 1/3 Encoder / ILS** 1:30 Z18 (aluminum) *Three-meter-long (9.84 ft) gates; **Inductive Limit Switch.

‘FUSION’ LINE Opening / Closing Time* Opening / Closing Cycles per Hour Gate weight HP End-of-stroke system Reduction ratio Rail length

Fusion

23 seconds 20 300 kg 1/4 Encoder 2:26 1.75 up to 4 m

Fusion

Fusion Plus

23 seconds 60 500 kg 1/2 Inductive Limit Switch 2:26 1.5 up to 6 m

Fusion Plus

*Three-meter-long (9,84 ft) gates.


CONTATTO

1500 IND

2500 IND

Cell phone-activated receiver

- Storage Capacity: 1024 telephone numbers; - Two settable outputs (pulse / retention); - Two inputs; - Sending of SMS to five distinct telephone numbers; - Outputs activated by Free Call; - PC communication by USB cable; - Real-time event monitoring; - Event history stored on a database.

CP-1000 Access Control System

Opening / Closing Time* Opening / Closing Cycles per Hour Gate weight HP End-of-stroke system Reduction ratio Pinion

Opening / Closing Time* Opening / Closing Cycles per Hour Gate weight HP End-of-stroke system Reduction ratio Pinion

6 seconds Heavy-Duty 1500 kg 1 ‘Hybrid’ 1:40 Z17 (Cast aluminum)

10 seconds Heavy-Duty 2500 kg 1 ‘Hybrid’ 1:50 Z17 (Cast aluminum) *Three-meter-long (9,84 ft)

*Three-meter-long (9,84 ft) gates.

- Storing capacity: 1000 user codes (One ProxCard and one remote control per user); - Connection capacity: - Four remote control receivers (each one with four outputs); - Twelve ProxCard readers; - Four relay modules (each one with four outputs). - Eight settable command inputs; - Storage of up to 1200 events on its memory; - Events shown on display; - PC connection via specific software; - Compatible to PS2 keyboard; - Blocking and unblocking of remote controls or ProxCards, without erasing them from memory; - ‘Guard System’ – used to monitor the presence of doorkeepers and watchmen.

MATRIX PRO ProxCard Reader

CONDOMINIUM Opening / Closing Time* Opening / Closing Cycles per Hour Gate weight HP End-of-stroke system Reduction ratio Pinion

6 seconds Heavy-Duty 1000 kg 1 ‘Hybrid’ 1:40 Z17 (Cast aluminum) *Three-meter-long (9,84 ft)

- Storing capacity: up to 999 ProxCards and 999 user codes. Each user code is linked to a ProXCard, i.e., both are stored on the same specific memory cluster; - Inputs to Two ProxCard Readers; - Sequential or addressable storage of remote controls / user codes; - Four-digit, seven-segment display; - Numeric / function keypad; - Three stand-alone outputs with solid state relay (SSR); - Outputs settable as pulse (NO / NC), retention, timed (NO / NC) and panic (NO / NC); - Erases each remote control at a time (sequentially or by address) or all remote controls at once; - Blocking and unblocking of remote controls / user codes, without erasing them; - Fifteen setting groups which can be used to define permissions of access to specific users; - Master code, used for programming (can be changed anytime); - Compatible to Transfer, with five positions on the memory available to backup of ProxCards and user codes, as well as to settings backup.

MATRIX Remote control Receiver

EURUS 2000

FORT Opening / Closing Time* Opening / Closing Cycles per Hour Gate weight HP End-of-stroke system Reduction ratio Pinion

15 seconds 80 1000 kg 3/4 ‘Hybrid’ 1:40 Z12 (aluminum) *Three-meter-long (9,84 ft)

Opening / Closing Time* Opening / Closing Cycles per Hour Gate weight HP End-of-stroke system Reduction ratio Pinion

15 seconds 80 2000 kg 1 ‘Hybrid’ 1:40 Z12 (Cast aluminum) *Three-meter-long (9,84 ft)

- Storing capacity: up to 999 remote controls and 999 user codes. Each memory cluster can store a remote control and / or a user code; - Addressable or sequential recording of remote controls / user codes; - Four-digit, seven-segment display; - Numeric / function keypad; - Three stand-alone outputs with solid state relay (SSR); - Outputs settable as pulse (NO / NC), retention, timed (NO / NC) and panic (NO / NC); - Erases each remote control at a time (sequentially or at random) or all remote controls at once; - Blocking and unblocking of remote controls / user codes, without erasing them; - Fifteen setting groups which can be used to define permissions of access to specific users; - Master code, used for programming (can be changed anytime); - Compatibility to four-button remote control.


‘FACILITY’ LINE FACILITY

‘TOP’ LINE TOP LIGHT

FACILITY 3 TRIMPOTS

- Programming via remote control; - Storage capacity: up to 160 Remote Controls; - End-of-stroke system: Inductive Limit Switch / Encoder; - Courtesy light module, electromagnetic lock module and warning light module outputs: - Input Accessories: - Push Button; - External receiver; - Photocells.

- Programming via trimmer: - Automatic timed closing; - Strength adjustment; - Deceleration adjustment; - Storing capacity: 170 remote controls; - End-of-stroke system: Inductive Limit Switch; - Input Accessories: - External receiver; - Push Button; - Photocells. - Output Accessories: - Courtesy light; - Electromagnetic lock.

- Programming via DIP Switch: - Storing capacity: 160 remote controls; - End-of-stroke system: Inductive Limit Switch / Encoder / ‘Hybrid’; - Courtesy light output; - Input Accessories: - Push Button; - Photocells.

TOP 4 TRIMPOTS

TOP

- Programming via DIP Switch: - Storing capacity: 160 remote controls; - End-of-stroke system: Inductive Limit Switch / Encoder / ‘Hybrid’; - Output Accessories: - Courtesy light; - Electromagnetic lock; - Warning light. - Input Accessories: - External receiver; - Push Button; - Photocells; - RS 485 communication device.

TRIFLEX - Adjustable speed; - End-of-stroke system: Inductive Limit Switch / Encoder / ‘Hybrid’; - Programming via DIP Switch: - Output Accessories: - Courtesy light; - Electromagnetic lock; - Input Accessories: - External receiver; - Push Button; - Photocells.

- Programming via trimmer: - Brake setting; - Strength setting; - Automatic timed closing; - Opening / Closing time. - Storing capacity: 1000 remote controls; - End-of-stroke system: Inductive Limit Switch;

- Input Accessories: - External receiver; - Push Button; - Opening command; - Closing command; - Photocells. - Output Accessories: - Electromagnetic lock; - Courtesy light; - Warning light.

ACESSO PRO - Prox card reader, used both to control access to restrict areas and to run sliding glass doors openers, gate openers and electric locks; - Self-learning rolling code; - Frequency: 433.92; - 12-volt power supply*: - Storing capacity: 100 ProxCards (99 user cards and 1 master card).

TOK

PICCOLO

*Not provided.

ACESSO - Wireless control access keypad; it can also be used to activate alarm systems, door and gate openers, automatic barriers and electromagnetic locks; - Code Learning; - 433.92 MHz operating frequency band (Crystal oscillator and Phase-Locked Loop – PLL) - Lithium battery; - 9 or 12-volt power supply*: - Nine user codes and one Master code; - 1 PGM output with negative signal; - The periods of time the device keeps active are individually set.

ALCANCE - Receiver used on PPA gate and sliding glass door openers; - Increases the remote controls storage capacity; - Easy installation; - Available on 292 and 433.92 MHz SAW.

MINI

GOOD LIGHT

- Reinforced grip; - Buttons embedded on the cover; - Exclusive battery holding system; - Circuit board with surface-mount components; - Resistant to falls and impacts; - Available on 292 MHz, 433.92 MHz and 433.92 MHz SAW.

- Device to activate gate / door openers by using the car’s headlight; - In order to open or close the gate, one must only activate the headlight high beam; - 12-V Power Supply; - Protection against power supply polarity inversion; - 433.92 MHz Transmission Frequency; - SAW-locked circuit.

- Four stand-alone buttons; - Increased stability of the signal to a better radio range; - Increased resistance to falls and impacts; - Used to activate alarm systems, as well as automatic gate and door openers; - 433,92 MHz SAW.

RELAY MODULE

PUSHBUTTON MODULE

Automatic gate openers - Alarm systems - Automatic door openers Automatic Barriers - Electric Motors Additional info on WWW.PPA.COM.BR .com/grupoppa |

The images contained on this catalog are merely representational and illustrative and are not intended to reflect actual views from any particular product. PPA reserves the right to change its products, as well as specifications and features, at its sole discretion without prior notice. Accessories sold apart. To a correct installation and use, always refer to the product technical manual, available on the website www.ppa.com.br Only a person trained by PPA must perform installation, maintenance and support services on the equipments.

ELECTRONIC CONTROL UNITIES