PPA Swing Gate Openers Catalog

Page 1


SWING GATE OPENERS LINE Piston

Power Supply Motor Power System Reduction Ratio Absorbed Current (A) Linear Speed Opening / Closing time (90º) Duty Cycle Rated Frequency Motor Rotation Speed RPM Capacitor Actuator Length End-of-stroke system HP

Piston 1000

127V or 220V Single-Phase 1:26 1.9A (220V) / 2.2A (127V) 1.9 meter/minute 10 seconds 20 cycles/hour 50 / 60HZ 1450 (50HZ) / 1750 (60Hz) 12µF (220V) / 25µF (127V) 0.75 meter Reed Digital (Encoder Hall System) 1/4

Unique

Power Supply Motor Power System Reduction Ratio Absorbed Current (A) Linear Speed Opening / Closing time (90º) Duty Cycle Rated Frequency Motor Rotation Speed RPM Capacitor Actuator Length End-of-stroke system HP

Power Supply Motor Power System Reduction Ratio Absorbed Current (A) Linear Speed Opening / Closing time (90º) Duty Cycle Rated Frequency Motor Rotation Speed RPM Capacitor Actuator Length End-of-stroke system HP

127V or 220V Single-Phase 1:26 1.9A (220V) / 2.2A (127V) 1.9 meter/minute 10 seconds 20 cycles/hour 50 / 60HZ 1450 (50HZ) / 1750 (60Hz) 12µF (220V) / 25µF (127V) 1 meter Reed Digital (Encoder Hall System) 1/2

Unique Digital

127V or 220V Single-Phase 1:26 1.9A (220V) / 2.2A (127V) 1.9 meter/minute 10 seconds 20 cycles/hour 50 / 60HZ 1450 (50HZ) / 1750 (60Hz) 12µF (220V) / 25µF (127V) 0.75 up to 1.25 meter Inductive limit switch system 1/4

Power Supply Motor Power System Reduction Ratio Absorbed Current (A) Linear Speed Opening / Closing time (90º) Duty Cycle Rated Frequency Motor Rotation Speed RPM Capacitor Actuator Length End-of-stroke system HP

127V or 220V Single-Phase 1:26 1.9A (220V) / 2.2A (127V) 1.9 meter/minute 10 seconds 20 cycles/hour 50 / 60HZ 1450 (50HZ) / 1750 (60Hz) 12µF (220V) / 25µF (127V) 0.75 up to 1.25 meter Reed Digital (Encoder Hall System) 1/4

Pivo Thor Power Supply Motor Power System Reduction Ratio Absorbed Current (A) Linear Speed Opening / Closing time (90º) Duty Cycle Rated Frequency Motor Rotation Speed RPM Capacitor Actuator Length End-of-stroke system HP

127V or 220V Single-Phase 1:26 1.6A (220V) / 2.8A (127V) 1.9 meter/minute 10 seconds 60 cycles/hour 50 / 60HZ 1740 (60Hz) 12µF (220V) / 25µF (127V) 0.75 up to 1 meter Reed Digital (Encoder Hall System) 1/2

"ROBOT" SWING GATE OPENERS Liger Universal 1/3 HP

Liger Universal 1 HP

Power Supply Motor Power System Reduction Ratio Absorbed Current (A) Duty Cycle Rated Frequency Motor Rotation Speed (RPM) Capacitor Gate leaf’s length End-of-stroke system HP

Power Supply Motor Power System Reduction Ratio Absorbed Current (A) Duty Cycle Rated Frequency Motor Rotation Speed (RPM) Capacitor Gate leaf’s length End-of-stroke system HP

220V Single-phase 1:40 1.7A 60 cycles/hour 50 / 60 Hz 1450 (50Hz) / 1750 (60 Hz) 15 µF Up to 3 meters Inductive limit switch system 1/3

220 V Single-Phase 1:40 1.7A 60 cycles/hour 50 / 60Hz 1450 (50Hz) / 1750 (60Hz) 15 uF (220V) Up to 3 meters Inductive Limit Switch System 1


FAST OPERATORS LINE Pivo Condominium

Pivo Industrial

Power Supply Motor Power System Reduction Ratio Absorbed Current (A) Linear Speed Opening / Closing time (90º) Duty Cycle Rated Frequency Motor Rotation Speed RPM Actuator’s length End-of-stroke system HP

Power Supply Motor Power System Reduction Ratio Absorbed Current (A) Linear Speed Opening / Closing time (90º) Duty Cycle Rated Frequency Motor Rotation Speed RPM Actuator’s length End-of-stroke system HP Pinion

220V Three-phase Three-phase 1:26 1.4A 1.9 up to 3.8 meters/minute 10 seconds 60 cycles/hour 50 / 60Hz 1740 / 4300 0.75 up to 1 meter Reed Digital (Encoder Hall System) 1/2

Bivolt (127V and 220V) 220V Three-phase 1:26 1.8A (220V) 1 meter/minute 28 seconds 60 cycles/hour 50 / 60Hz 1740 / 4300 1 meter Reed Digital (Encoder Hall System) 1/2 Enveloping bronze pinion

ELECTRONIC CONTROL UNITS ELECTRONIC SYSTEM TO FAST SWING GATE OPENERS SPI: Swing Gate System enhanced with Variable-Frequency Drive - Communication between ECUs through RS-485 network; - Bivolt (127 and 220V); - Variable-Frequency Drive (Inverter); - Adjustable speed; - High-voltage indicator; - Reed Digital (Encoder Hall System) running indicator; - Easy and fast installation through DIP switches individual function selection; - Push-button, external receiver and photocell (photo-eye) inputs; - Outputs to courtesy light and electromagnetic lock.

Digital Dupla

ELECTRONIC SYSTEMS TO DOUBLE SWING GATES Sistema Link Pivo

- Embedded RF 433,92MHz Module Receiver; - Code Learning; - Capacity to up to 160 remote controls, regardless if either the two buttons or only one have been programmed; - Individual programming to each remote control. - Input Accessories: Photocells; Loose RF receiver module; Push Button. - Output Accessories: Lock module; Courtesy light module; Warning light module. - Control of the motor: - Soft start; - Electronic clutch; - Electronic break; - Individual memorization of the opening / closing path time to the motors which delay on opening and on closing.

- Master ECU (Facility TOP ECU with embedded RF module); - Slave ECU (Facility Link* ECU without RF module); - RS-485 Serial communication network (2 serial modules**; one to each ECU, linked through communication cable); - Compatible to Encoder Hall System and Inductive limit switch system. * Similar to New Facility ECU; ** Modules sold apart.

ELECTRONIC SYSTEMS TO SINGLE SWING GATES New Facility

Facility Top

- Encoder Hall System or Inductive Limit Switch System; - RF 433,92MHz Receiver Module; - Memory to up to 160 Code-learning Remote Controls, with either all buttons memorized or just some of them; - Automatic acquisition of the gate limits adjustment; - Selection of Automatic Timed Closing or Push-To-Open modes through remote control; - Programming of automatic closing interval through remote control (maximum interval is 4 minutes); - Electronic clutch (strength) setting through remote control; - Erasing of all remote controls through a remote control; - Command to set the ECU (standard setting), through a remote control; - RS-485 Serial Interface to swing gate openers and PC access control (Serial ECU).

- Encoder Hall System or Inductive Limit Switch System; - RF 433,92MHz Receiver Module; - Memory to up to 160 Code-learning Remote Controls, with either all buttons memorized or just some of them. -Inputs: Photocell (Photo eye); Loose RF receiver module; RS-485 serial module; 2.40GHz wireless module. - Outputs: Warning light module; Electromagnetic lock module; Courtesy light module. - Motor control: Soft starting; - Applications: Electronic clutch; Sliding gate openers; Electronic brake; Overhead gate openers; Pulsating torque. 1-leaf or 2-leaf Swing gate openers.


Matrix Receiver

Alcance Receiver - Capacity to up to 1020 remote controls and 1020 user passwords; each one is linked to a remote control (same position in the memory); - Addressable or sequential recording of remote controls / passwords; - Four-digit, seven-segment display; - Numeric / function keypad to programming and password typing; - Three stand-alone outputs with solid state relay (SSR); - Outputs settable as as pulse (NO / NC), retention, timed (NO / NC) and panic (NO / NC); - Erases each remote control at a time (sequentially or by address) or all remote controls at once; - Blocks and unblocks remote controls / passwords, without erasing them; - 15 groups used to set the buttons of either the remote controls or the passwords, in relation to the outputs; - Reprogrammable Master password to programming; - Compatible to four-button remote control.

Good Light

Acesso Pro

Acesso

- Receiver used on PPA gate and sliding glass door openers; - Expands the remote controls recording capacity; - Capacity up to 160 remote controls, either with all buttons set or not; - Easy installation; - Available on 292 and 433.92 MHz versions

Now with lithium battery, 433.92 MHz operating frequency band and PhaseLocked Loop (PLL)!

- Wireless password-activated transmitter to control access to restrict precincts; it can also be used to activate alarm systems, sliding glass door openers, gate openers, automatic barriers, electric fences and electromagnetic locks; - 433.92 MHz operating frequency band (Crystal oscillator and Phase-Locked Loop – PLL) - Lithium battery; - 9 or 12 volts power supply*: - Nine user passwords and one Master password; - 1 (programmable) PGM output with negative signal; - The periods of time the device keeps active are individually programmed.

- Prox card reader, used to control access to restrict areas. It can be used to run sliding glass doors openers, gate openers and electric locks; - 433.92 Self-learning rolling code; - 9 or 12 volts power supply*: - Up to 100 prox cards (99 user cards and 1 master card) in its memory. *Not provided.

- Good light is a device which makes it possible to open / close your gate by using the car’s headlight; - In order to open or close the gate, one must only activate the headlight high beam; - 12V Power Supply; - Protection against power supply polarity inversion; - 433.92 MHz transmission frequency; - SAW-locked circuit.

*Not provided.

TX Tok

TX Mini

- Reinforced grip; - Buttons embedded on the cover; - New battery holder; - Circuit board with surface-mount components; - Resistant to falls and impacts; - Available on 292 and 433.92 MHz versions.

- Used to activate gate openers; - Buttons embedded on the cover; - Resistant to falls and impacts; - Circuit board with surface-mount components; - Available on 433.92 MHz.

TX Piccolo - A new, modern and innovative design; - Four stand-alone buttons; - Increased stability of the signal to a better radio range; - Increased resistance to falls and impacts; - Used to activate alarm systems, as well as gate and door openers; - Available on 433.92 MHz.

Relay Module

Pushbutton Module

The relay module is a separate hardware device used for remote switching of the following devices: - Courtesy Light: Turns on the lights of the garage when the opener is activated; - Lamp Indicator device: Starts up when the automation starts working; - Electromagnetic lock: Activates electromagnetic locks.

- It allows a better connection between receiver and pushbutton in the electronic control units, insulating the command line; - This device is quite used in guardhouses, or when the distance between the electronic control unit and the push button is large. It allows the remote device switching.

Check our sliding and overhead gate openers, as well as our alarm system line. Visit us:

www.ppa.com.br

The images contained on this catalog are merely representational and illustrative and are not intended to reflect actual views from any particular product. PPA reserves the right to change its products, as well as specifications and features, at its sole discretion without prior notice. Accessories sold apart. To a correct installation and use, always refer to the product technical manual, available on the website www.ppa.com.br Only a person trained by PPA must perform installation, maintenance and support services on the equipments.

ACCESSORIES


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.