9329 kingsley crescent richmond

Page 1

12.19M

PROJECT DATA:

ZONING: RS2/B - SINGLE FAMILY RESIDENTIAL ZONE

ALL EXISTING CALCULATIONS: ALLOWED F.A.R. = 0.40 x 464.5 S.M = 185.80 S.M. (1956.80 SFT.) DECK

55'-115 8" [17.06m]

LOT #2 AREA: 416.95 S.M. = 4488 SFT. LOT COVERAGE MAX. ALLOWED LOT COVERAGE IS 45%

112'-35 8" [34.23m]

LOT AREA:

EXISTING HOUSE 9329 KINGSLEY CRESCENT RICHMOND, BC

45% OF S.A. = 2019.60 SFT. PORPOSED LOT COVERAGE (1873 SFT.) FLOOR AREA RATIO (F.A.R): MAIN FLOOR AREA = 1637 SFT.

4'-25 8" [1.28m]

4'-25 8" [1.28m]

EXCLUDING GARAGE & DECKS DECK

GARAGE FLOOR AREA = 247 SFT. INCLUDING VESTIBULE

PROPOSED SECONDARY SUITE AREA= 865 SFT. UPPER FLOOR AREA = 1873 SFT.

19'-83 8" [6.00m]

BUILDING - INTERIOR DESIGNERS

PROPOSED F.A.R. = M 1637 SFT. + 1563 SFT. = 297.29 S.M. (3200SFT.) LEGAL DESCRIPTION: LOT #2, PLAN 55101, SECTION 25 - 4 - 6

34.21M

UDC DESIGN CENTER LTD

PID: 003-868-915

36'-814" [11.18m]

CIVIC ADDRESS: 9329 KINGSLEY CRESCENT, RICHMOND,BC.

EXCLUDING DECKS & OPEN TO BELOW

UPPER FL. DECK AREA = 63(F) + 224 (R) =287 SFT. UPPER FL. OPEN TO BELOW AREA = 22 SFT.

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

40'-03 8" [12.20m]

SHEET TITLE:

Mr. Murad and Khair Baluch PROJECT: CIVIC ADDRESS: 9329 KINGSLEY CRESCENT RICHMOND, BC LEGAL DESCRIPTION:

SITE PLAN

DRAWN BY:

G.S.M.

PROJECT NO.

CHECKED BY:

B.M.

176

DATE:

JULY. 2016

FILE NO.

SCALE:

1/4"=1'-0"

V11

SHEET NO:

A

1/4


A A1

A A1

32'-0"

32'-0" 17'-6"

14'-6" 5'-7"

6'-6"

2'-5"

5'-1"

6'-1"

6'-4"

18'-10" 6'-3"

5'-7"

13'-2" 3'-11"

3'-1"

6'-7"

6'-7" 6050DC

BEDROOM

18'-9" x 12'-0"

3068

2668

22'-10"

5036DC

FAMILY 12'-1" x 18'-6"

4036DC

2DB6918

BEDROOM

BEDROOM

BCB30

8'-11" x 11'-2"

11'-0" x 11'-7"

2DB6917

BCB52

SB51

2'-4" x 6'-8"

2668

1830DC

7'-0" x 6'-5"

2668

LIVING/DINING

17'-5" x 15'-10"

2668

6'-4" x 13'-7"

MASTER BDRM

B80

ENTRY

13'-0" x 24'-5" 13'-11"

LIVING 13'-1" x 20'-1"

20'-8"

17'-3"

GARAGE 10'-10" x 20'-4"

57'-5"

6'-9"

CLOSET

SB42

2668

20'-11"

BCB30

B B1

25'-2"

UP

2668

SB54

BATH 3'-4"

3040DC

FIRE RATED WALL

2668

7'-0" x 8'-1"

6'-9"

FIRE RATED DOOR

Elevation 6

2'-6" 4'-9"

B B1

2668

S

BATH

RB59

2668

RB45

B39

S CO

B30

3'-5"

3'-8"

2668

B B1

11'-3" x 13'-0"

2668

2668

6'-3" x 5'-6"

KITCHEN SMOKE ALARM & CARBON MONOXIDE (CO) ALARM

1830DC

BCB36

BATH

6'-11"

12'-0" x 27'-1"

2668

U223684R

8'-6"

3040DC

KITCHEN

FIRE RATED DOOR SB4718

2030DC

SB39

2668

2668

2668

55'-11"

57'-5"

BCB33

7'-10" x 6'-0"

FIRE RATED WALL

3'-9"

BATH 2668

2030DC

BCB35

6'-5"

4'-7"

B39

3'-2" 2'-8"

5'-10"

B B1

2668

SB33

1'-9"

55'-11"

6'-4"

SMOKE ALARM & CARBON MONOXIDE (CO) ALARM

3040DC

2668

5'-1"

2668

9'-4" x 10'-10"

12'-4"

BEDROOM

11'-4" x 10'-2"

14'-10"

BEDROOM

4040DC

10'-11"

2668

6'-1"

2668

25'-6"

5050DC

S CO

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

3068

11'-8" x 11'-6"

DECK

11'-11"

12'-3"

11'-11"

4040DC

9070

1050FX

2060FX

3068

5068

2060FX

8050TS

7050TC

11'-7"

7'-1"

6'-3" 17'-10"

7'-1" 14'-2"

2'-4"

32'-0"

5'-1"

5'-2"

2'-3"

3'-0"

17'-10"

7'-0"

7'-2" 14'-2"

32'-0"

A A1

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

A A1

CLIENT:

SHEET TITLE:

Mr. Murad and Khair Baluch PROJECT: CIVIC ADDRESS: 9329 KINGSLEY CRESCENT RICHMOND, BC LEGAL DESCRIPTION:

MAIN & SECOND FLOOR PLAN

DRAWN BY:

G.S.M.

PROJECT NO.

CHECKED BY:

B.M.

176

DATE:

JULY. 2016

FILE NO.

SCALE:

1/4"=1'-0"

V11

SHEET NO:

A

2/4


PEAK ROOF. LVL.

PEAK ROOF. LVL. 12 4

12 4

U/S CEILING. LVL.

U/S CEILING. LVL.

3040DC 2060FX

5068

8050TS

2060FX

SECOND FLOOR LVL.

SECOND FLOOR LVL.

1050FX

4040DC

7050TC

3068

MAIN FLOOR LVL.

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

3040DC 9070

MAIN FLOOR LVL.

PEAK ROOF. LVL.

PEAK ROOF. LVL. 12 4 12 4

U/S CEILING. LVL.

U/S CEILING. LVL.

1830DC 4036DC

1830DC

5036DC

6050DC 3068

SECOND FLOOR LVL.

SECOND FLOOR LVL.

2030DC

2030DC 3040DC

4040DC

5050DC

3068

MAIN FLOOR LVL.

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

MAIN FLOOR LVL.

CLIENT:

SHEET TITLE:

Mr. Murad and Khair Baluch PROJECT: CIVIC ADDRESS: 9329 KINGSLEY CRESCENT RICHMOND, BC LEGAL DESCRIPTION:

ELEVATIONS

DRAWN BY:

G.S.M.

PROJECT NO.

CHECKED BY:

B.M.

176

DATE:

JULY. 2016

FILE NO.

SCALE:

1/4"=1'-0"

V11

SHEET NO:

A

3/4


PEAK ROOF. LVL. DUROID ROOF

BUILDING PAPER ON 12" PLYWOOD ENG.TRUSSES @24" O/C R-40 BATT INSULATION 6 MIL POLY V.B. (LAPPED JOINTS,SEAL ELECT. OUTLETS) (WARM SIDE) 5 8" GYPSUM BOARD BUFFLES 2" CLEAR FROM TOP

1

12

ATTIC

4

SECTIONAL DETAILS AND SPECIFICATIONS:

ATTIC VENTILATION AS PER BUILDINGCODE A/300 OF INSULATED CEILING AREA MIN. 25% OF VENTING @TOP & 25% @ BOTTOM

1

- ROOF FINISH: 210 # ASPHALT SHINGLES ROOF - STARTER STRIP - 716" OSB SHEATHING c/w. H. CLIPS - PREFAB. ENG. TRUSSES @ 24" O.C. - R-50 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.

2

MASTER BDRM DECK

4

LIVING/DINING

BEDROOM

2

4 3

ENTRY

4

- FINISH FLOOR: TO OWNERS SPEC'S - 0'-6" CONC. SLAB - 10 GA 6 x 6 WIRE MESH - 6 MIL. POLY. V.B. - R-10 RIGID INSULATION - MIN. 12" COMPACTED GRANULAR FILL

7

FOUNDATION WALLS: - 2 x 6 SILL PLATE - 8" CONC. FOUNDATION WALL - 2 COATS OF ASHPALT EMULSION TO EXTERIOR FACE - 2 - 15M T & B, 10M @16" O.C E/W.1.F UP TO GRADE

EXTERIOR WALLS (2 hr FRR): - STUCCO ON WIREMESH - METAL LATH - 19MM (3/4") AIR SPACE / @ 16" O.C. - 15# BREATHER TYPE BUILDING PAPER - 15 32" SHEATHING - 2 x 6 STUDS @ 16" O.C. - R-20 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.

MAIN FLOOR LVL.

1

12 4

ATTIC ATTIC VENTILATION AS PER BUILDINGCODE A/300 OF INSULATED CEILING AREA MIN. 25% OF VENTING @TOP & 25% @ BOTTOM

2

NET BACKFILL HT.

A

B

LESS THAN 7'-6"

0"

0"

7'-6" TO 8'-0"

18"

20"

8'-1" TO 9'-0"

14"

20"

9'-1" TO 10'-0"

12"

20"

NOTE: 1. REBAR TO BE 230 MPa MINIMUM. 2. CONCRETE TO BE 20 MPa MINIMUM. 3. BACKFILL NOT TO EXCEED 20 KN/ cubic METER

LIVING/DINING

CLOSET

4

5 8" ANCHOR BOLT @ 48" o.c. (MAX. OF 1 PLATE UNDER JOIST.)

GARAGE SLAB OR FINISHED GRADE

SECOND FLOOR LVL.

MAX. COVER 2"

BATH

3

KITCHEN

HORIZONTAL STEEL = 'B' (LAP JOINTS 18" MINIMUM) APPLY DAMPROOFING AS REQ. BY N.B.C. SECT.9-13

6

4" CONC. SLAB ON 6 MIL. POLY. V.B. ON 6" COMPACTED GRANULAR FILL

8" REINFORCED CONCRETE FOUNDATION WALL

MAIN FLOOR LVL. 24"

FLOOR JOIST

W1(C): -38mm(112")X 89mm(321") STUDS SPACED 400mm OR 600mm -WITH 89mm THICK ABSORPTIVE MATERIAL -15.9mm(5 8") TYPE X GYPSUM BOARD

5

8" TYPE "X" GYPSUM BOARD ON BOTH SIDES CONTINUOUS TO UNDERSIDE OF FLOOR SHEATHING (HATCHED AREA)

F.R.R WALL DETAIL

SUBFLOOR

NOTCH OUT 21" TYPE "X" GYPSUM BOARD FOR FLOOR JOISTS

5

8"

TYPE "X" GYPSUM BOARD AGAINST SEPARATION WALL

-METAL FURRING CHANNELS SPACED 600mm O.C. -15.9mm (58") TYPE X GYPSUM BOARD

15M @ 15" o.c.

ON PLAN

AS NOTED

8"

4"Ø PERIMETER DRAIN TILE WITH DRAIN ROCKS

W1(C): -38mm(121")X 89mm(312") STUDS SPACED 400mm OR 600mm -WITH 89mm THICK ABSORPTIVE MATERIAL -15.9mm(5 8") TYPE X GYPSUM BOARD

30 MIN. F.R.R. ASSEMBLY DETAIL

212" RIGID INSULATION (N.I.C.) TO BELOW FROSTLINE OR 2x4 FURRED WALL w/ R12 F.G. BATT INSUL. (N.I.C.) WHERE INDICATED

VERTICAL STEEL = 'A' (ALTERNATE HOOKS)

4

A

NET BACKFILL HEIGHT

5

- 2" AIR SPACE - 2 x 4 SPF # 2 STUDS @ 24" O.C. (U.N.O.) - R-14 BATT. INSULATION - 6 MIL. POLY. V.B. - C/W TUCK TAPE JOINTS - 1/2" DRYWALL

EXTERIOR WALL CONSTRUCTION

TYPICAL FLOOR CONSTRUCTION

2" FROM GARAGE SLAB OR SIDEWALK 8" MIN. FROM FINISH GRADE

INTERNAL INSULATED WALL

F5(D): -SUBFLOOR OF 15.5mm PLYWOOD, OSB OR WAFERBOARD OR 17mm TONGUEAND GROOVE LUMBER -38mm(121")X 235mm(914") WOODFLOOR JOISTS -ABSORPTIVE MATERIAL IN CAVITY -METAL FURRING CHANNELS SPACED 600mm O.C. -15.9mm(58") TYPE X GYPSUM BOARD

SUPPORTED WALL (10M BAR)

U/S CEILING. LVL.

BATH

BASEMENT FLOOR:

INTERIOR PARTITIONS ( 1 hr FRR):

6

BATH

6

- 1/2" GYPSUM BOARD (BOTH SIDES) - 2 x 4 STUDS @ 16" O.C. - INSUALTED CAVITY

KITCHEN

HALLWAY

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

3

PEAK ROOF. LVL.

- 5 8" TYPE "X" GYPSUM BOARD (FIN. AS PER OWNER)

- BUILT-IN GUTTER - 2 x 12 FASCIA BOARD - METAL SOFFIT WITH 2" CONTINUOUS SCREENED VENT

SECOND FLOOR LVL.

MAIN AND UPPER FLOOR (1 hr FRR): - FINISH FLOOR: TO OWNERS SPEC'S - P.T. 2x10 @16 o.c. JOISTS AS PER MANUFACTURERS SPECS - 11/2"th. CONCRETE TOPPING - R-40 SPRAT FOAM INSULATION

EAVES:

5

DUROID ROOF BUILDING PAPER ON 12" PLYWOOD ENG.TRUSSES @24" O/C R-40 BATT INSULATION 6 MIL POLY V.B. (LAPPED JOINTS,SEAL ELECT. OUTLETS) (WARM SIDE) 5 8" GYPSUM BOARD BUFFLES 2" CLEAR FROM TOP

5

ROOF:

U/S CEILING. LVL.

DETAIL AT 'A'

F5(D): -SUBFLOOR OF 15.5mm PLYWOOD, OSB OR WAFERBOARD OR 17mm TONGUEAND GROOVE LUMBER -38mm(112")X 235mm(914") WOODFLOOR JOISTS -ABSORPTIVE MATERIAL IN CAVITY -METAL FURRING CHANNELS SPACED 600mm O.C. -15.9mm(85") TYPE X GYPSUM BOARD

F.R.R. CEILING DETAIL

2-15M CONT. AS NOTED ON PLAN

SUPPORTED WALL SECTION

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

SHEET TITLE:

Mr. Murad and Khair Baluch PROJECT: CIVIC ADDRESS: 9329 KINGSLEY CRESCENT RICHMOND, BC LEGAL DESCRIPTION:

SECTIONS AND DETAILS

DRAWN BY:

G.S.M.

PROJECT NO.

CHECKED BY:

B.M.

176

DATE:

JULY. 2016

FILE NO.

SCALE:

1/4"=1'-0"

V11

SHEET NO:

A

4/4