UDC DESIGN CENTER LTD BUILDING - INTERIOR DESIGNERS

Driveway Material: Exposed Aggregate OR Pavers OR Stamped Concrete. Front Sidewalk to match.

Front Yard LANDSCAPING: Minimum 2 shrubs Minimum Size: 5 Gallon Pot Minimum 10 annuals in a 10sft. Planting Bed PLUS replacement trees as per apporoved tree plan

E.EL. 358.1 P.EL. 358.5

CLIENT:

E.EL. 358.5 P.EL. 358.5

LINE OF UPPER FLOOR

2'-614"

BSMT. FL. LVL. 353.22 AVE. GRADE. LVL. 358.1 MAIN FL. LVL. 352.42 SECOND FLOOR LVL. 373.62 U/S CEILING LVL. 381.62 ROOF RIDGE LVL. 387.64 BSMT. - IN GRND 72%

E.EL. 358.4 P.EL. 358.5

E.EL. 357.7 P.EL. 358.5 357.41

REAR DECK DN

DN

37'-11" [11.56m] BLDG. WIDTH

4'-10" [1.48m]

7' [2.12m] 45'-214" [13.77m]

MR.DOM PINEDA

CIVIC ADDRESS:8066 -18TH AVE, BURNABY, BC

137'-9" [41.97m]

40'-5" [12.32m]

5' [1.51m]

137'-9" [41.97m]

PROJECT:

4'-9" [1.45m]

PORCH

27'-65 8" [8.40m]

27'-65 8" [8.40m]

8 CM CAL. SWEET GUM 15 SHRUBS OF 5 GAL POT SOD TO STREET

49'-6" [15.08m]

40'-512" [12.33m] BLDG. DEPTH

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

8 CM CAL. SWEET GUM 15 SHRUBS OF 5 GAL POT SOD TO STREET

d

to

ove em r e

b

d

ove em er

69'-9" [21.26m]

b to

REAR LAWN SOD MIN 300MM THICK LAYER TOP SOIL

E.EL. 362.4 P.EL. 363.1

AT BACK 363.90

to

be

E.EL. 363.3 P.EL. 363.3

1

49'-1112" [15.23m]

ove

36 3.

6 7% slope 36 2. L.

site

E.EL. 362.8 P.EL. 363.3

E.E

8.75% slope

t

2% slope

re

ved mo AT FRONT 363.65

L.

t

e ob

b

E.EL. 363.0 P.EL. 363.65

E.E

8.75% slope

E.EL. 363.4 P.EL. 363.65

em er

rem

d

4' [1.22m]

to

10' [3.05m]

SHEET TITLE:

d ove

CONCRETE DRIVEWAY

d ove rem

E.EL. 361.9 P.EL. 362.6

GARAGE

SECONDARY SUITE PARKING PAD

e ob

3' [0.91m]

22' [6.71m]

20'-6" [6.25m]

24'-11" [7.59m]

SCALE:

DATE:

CHECKED BY:

DRAWN BY:

1/8"=1'-0"

SEP. 2016

B.M.

G.S.B

V14

FILE NO.

239

PROJECT NO. SHEET NO:

A

1/6


SPECIFICATIONS AND GENERAL NOTES: SECTION 07200

38'-0"

VAPOR BARRIER / VAPOR RETARDER PRODUCT: MATERIAL TO CONFORM TO CAN2-51.33-M80, TYPE II, 6 MIL IN WALLS. 3. EXTERIOR WINDOWS: ALUMINUM CLADDED WOOD FRAME OR VINYL FRAME EXECUTION: APPLY VAPOR BARRIER TO WARM SIDE (INTERIOR SIDE) OF INSULATED WALLS. INSTALL VAPOR BARRIER TO PROTECT THE ENTIRE WALL SURFACE, INCLUDING FRAMING MEMBERS. 4. WINDOW TRIMS: HARDITRIM APPLY VAPOR BARRIER HORIZONTALLY TO WALLS. LAP JOINTS MINIMUM OF 4" (100MM). 5. SOFFITS: VENTED HARDISOFFIT SEAL TO FRAMING WITH ADHESIVE OR PRESSURE SENSITIVE TYPE. SEAL VAPOR BARRIER RETARDER TO PENETRATIONS. GENERAL NOTES WATERPROOF WALLBOARD REQUIRED AS TILE BASE AROUND TUBS AND SHOWERS AS PER BCBC 9.29.10.4. 1SECTION 07270 2- CEILING AND WALLS TO HAVE 6 mil U.V.POLY FULLY CAULKED AS PER BCBC 9.25.2.3 3- 5/8" DRYWALL REQUIRED TO CEILING MEMBERS AT 24" O.C. AS PER BCBC 9.29.5.3. AIR BARRIER / SHEATHING MEMBRANE 4- PROVIDE 5" GRAVEL AS PER BCBC 9.14.4.2 AND 6 mil U.V.POLY AS PER BCBC 9.13.6 UNDER SLAB PRODUCT: TWO LAYERS OF 30 MINUTE ASPHALT SATURATED BUILDING PAPER CONFIRMING 5- A BOND BREAKING MATERIAL IS REQUIRED BETWEEN FOUNDATION AND SLABS TO CAN-51.32M77 AND TO U.S. UUB-790a. 6- DOORS BETWEEN GARAGE AND DWELLING TO BE A SOLID CORE, SELF CLOSING, EXECUTION: AIR BARRIER MEMBRANES MUST BE APPLIED IN STRICT ACCORDANCE WITH THE WEATHER STRIPPED DOOR AS PER BCBC 9.10.13.15. MANUFACTURER'S PRINTED INSTRUCTIONS AT ALL THE LOCATION IN THE EXTERIOR OF THE BUILDING ENVELOPE WHERE AIR IS FREE TO INFILTRATE THROUGH JOINTS IN COMPONENTS OF 7- THICKEN SLAB AT GARAGE ENTRY AS PER STRUCTURAL DRAWINGS. THE ASSEMBLIES AND AT JUNCTIONS WITH DISSIMILAR MATERIALS, CHANGES IN PLANE AND AT THE ROOF 8- HEATING SYSTEM IS RADIANT HEAT FOR ALL FLOORS INSTALL SHEATHING MEMBRANE OVER EXTERIOR SHEATING. 9- ENGINEERED ROOF TRUSS DESIGN REQUIRED PRIOR TO INSTALLATION. INSTALL ONE (1) LAYER OF ASPHALT SATURATED BUILDING PAPER HORIZONTALLY IN SUCCESSIVE 10- PROVIDE 8" CLEARANCE BETWEEN GRADE AND SIDING. STRIPS BEGINNING 2" (50MM) BELOW THE LOWEST POINT OF THE WALL FRAMING AND PROGRESSING UPWARDS WITH EACH SUCCEEDING SHEET. 11- PRIOR TO FRAMING AND INSPECTION SUBMIT MECHANICAL VENTILATION/AIR CONDITIONING AND LETTER OF SUPERVISION B PROF.ENG.OR CERTIFIED H.R.A.I OR HVC TECHNICIAN. OVERLAP UPPER SHEET OVER LOWER SHEET A MINIMUM OF 4" (100MM) SO THAT LAPS ARE ARRANGED TO SHED WATER. 12 - DWELLING SECURITY AS PER # 9.6.8 END LAPS MUST HAVE A MINIMUM 12" (300MM) OVERLAP. STAGGER VERTICAL LAPS A MINIMUM 13 - PROVIDE FLASHING BETWEEN HORIZONTAL INTERSECTION OF DIFFERING WALL FINISHES. OF 48" (1200MM). RETURN SHEET OVER FLASHINGS.

12'-412" 2'-0"

INSULATION: PRODUCTS: EXTRUDED POLYSTYRENE: STANDARD CGSB51-GP-20M,TYPE 4. R: 5 PER INCH, RICHNESS: AS REQUIRED TO MEET P VALUE, LOCATION: FOUNDATION INSULATION. EXPANDED POLYSTYRENE: STANDARD: CGB51-GP-20M, TYPE 2, R: 4 PER INCH. THICKNESS: AS REQUIRED TO MEET R VALUE. LOCATION: CAVITY WALLS. BATT INSULATION: STANDARD: CSA A101-M83, TYPE 1. R VALUE: 19 . LOCATION WITHIN WOOD STUD WALLS, AND R 38 WITHIN CEILING. EXECUTION: EXTEND BOARDS A MINIMUM OF 24" (600MM) BELOW GRADE. INSTALL PERIMETER INSULATION USING MECHANICAL FASTENERS OR ADHESIVE. BUTT JOINT TIGHTLY, OFFSET HORIZONTAL AND VERTICAL JOINTS. USE LARGEST POSSIBLE SHEETS TO REDUCE NUMBER OF JOINTS. DO NOT USE CHIPPED OR CRACKED INSULATION BOARDS. PROTECT INSULATION WITH PRESSURE TREATED PLYWOOD AND PRE FINISHED METAL CAP FLASHINGS. INSULATION IN CAVITY WALLS: APPLY INSULATION IN CAVITY WALLS USING IMPALE TYPE CLIPS. FASTEN BOARDS WITH A MINIMUM OF (4) FASTENERS PER 24" X 48" (600MM X 1200MM) BOARD. BATT INSULATION: INSTALL FULL WIDTH AND LENGTH BETWEEN STUDS AND FRAMING MEMBERS TO FIT SNUGLY WITHOUT BUCKLING, CREASING OR CRUSHING. IN WALLS, INSTALL LOWER BATT FIRST; UPPER BUTT INSTALLED TO BUTT WITH THE FIRST AND ANY EXTRA LENGTH OF INSULATION TRIMMED AT TOP. FIT INSULATION TIGHT TO ELECTRICAL BOXES, PLUMBING AND HEATING PIPES AND DUCTS, AROUND EXTERIOR DOORS AND WINDOWS AND OTHER PROTRUSIONS. INSTALL INSULATION IN CONTINUOS CONTACT WITH INTERIOR SHEATING. ACCESS HATCHES: INSULATE ACCESS HATCHES TO THE SAME R VALUE AS THE ASSEMBLY IN WHICH THEY OCCUR.

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

5'-012"

4'-4"

3'-4"

4026RS

10'-5" 2'-6"

10'-5"

DN

15'-9"

3026RS 4'-821"

8'-1012"

5'-5"

2668 3'-9"

Inter Connected Door & Frame must have 20 min. fire rated CW self closing

FIRE RATED, SOLID CORE, WEATHER STRIPPED, SELF Extent of Suite1Hr. fire rated for walls and clg. CLOSING DOOR

4'-0"

2668 2668

SMOKE ALARM & CARBON MONOXIDE (CO) ALARM

2668

LEGEND:

2668

2668 2'-6" WIDTH x 6'-8" HEIGHT WIN. - CASEMENT

2668

3'-3"

FIRE RATED, SOLID CORE, WEATHER STRIPPED, SELF CLOSING DOOR

WIN. - FIXED SAFETY GLASS - WINDOW

36" HIGH HANDRAIL UP

WH

HOLLOW CORE - DOOR

40'-6"

2668

15R@7 1/2" 14T@10"

HRV UNIT

3'-4"

3068

RS / LS WIN. - SLIDE TO RIGHT/LEFT

3'-814"

5'-612"

3'-612"

2'-7"

2668

3068

9'-421"

3'-1134"

WELL 2'-10"X15'-0"

40'-6"

6'-1021"

8'-0"

5'-234"

3020RS

8'-234"

15'-7"

12'-412" 15'-0"

3. 4. 5. 6. 7.

5'-712"

6'-9"

5'-10"

DN 8R@ 7 14"

ROUGH CARPENTRY

SCW

1'-6"

SMOKE ALARM & CARBON MONOXIDE (CO) ALARM

4'-5"

WATER CLOSET

12'-10" OVERHEAD EXHAUST FAN

9'-3"

2668 2668

5'-2"

4'-414"

2668

INTERCONNECTED HARDWIRED SMOKE DETECTORS WITH A BATTERY BACKUP SMOKE ALARM & CARBON MONOXIDE (CO) ALARM

24'-9"

2'-8"

4'-021"

9'-0"

4'-414"

9'-6"

3026RS

5'-621"

NOTE: ALL LINTELS < 6'-0" LENGTH, SHALL BE 2 - 2x10 SPF # 2 W/ NO SPLICING PERMITTED B/W SUPPORTS

3'-612" 5'-5"

2'-221"

3026RS

ALL LINTELS > 6'-0" LENGTH, SHALL BE 3 - 2x10 SPF # 2 W/ NO SPLICING PERMITTED B/W SUPPORTS LEGAL SUITE AREA, CEILING TO BE 5/8" TYPE "X" DRYWALL REINFORCED CONC. RETAINING WALL

3'-8"

4'-4"

5'-614"

SOLID CORE W/ WEATHER SEAL - DOOR WASH BASIN

3030

5'-134"

2668

5/8" TYPE "X" GWB EACH SIDE OF 2"X6" WALL - 45 min. RATED

2'-0"

1'-11"

9'-1012"

LUMBER GRADES: AS SHOWN ON THE DRAWINGS AND / OR ACCORDING TO NLGA STANDARD GRADING RULES FOR CANADIAN LUMBER, MAXIMUM MOISTURE CONTENT 19%. ROOF SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR, METAL "H" CLIPS TO SUPPORT EDGES: 1/2" (12.5MM) FOR 16" (400MM) O/C SUPPORT; 5/8" (15.9MM) FOR 24" (600MM) O/C SUPPORT. INTERIOR FLOOR SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR OR SPRUCE. USE TO PLYWOOD WHERE REQUIRED BY STRUCTURAL DESIGN. FLOOR UNDERLAY: THREE PLY, 11/32" (8.5MM) THICK, SPRUCE PLYWOOD WITH THE FINISH FACE SECTION 07300 DOUBLE SANDED AND THE BACK FACE SLIGHTLY SANDED. THE CONTRACTOR MUST CONFIRM PRIOR TO INSTALLATION THE FLOORING UNDERLAY THAT IT IS ACCEPTABLE TO THE RESILIENT FLOORING MANUFACTURER. ASPHALT SHINGLE AND CEDAR SHINGLE/SHAKES IF APPLICABLE EXTERIOR DECK SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR, T&G. USE SELECT TIGHT FACE PLYWOODPRODUCTS: ASPHALT SHINGLES: ACCEPTABLE MATERIALS AS LISTED IN THE RCABC ROOFING PRACTICES MANUAL, TAB 2" ACCEPTABLE MATERIALS LIST", LATEST EDITION. SHINGLE MATERIALS MAY BE ORGANIC UNDER PVC DECK WATERPROOFING. OR FIBERGLAS CORE PRODUCT. EXTERIOR WALL SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR OR SPRUCE. WOOD SIDING IF REQUIRED IN DESIGN: WESTERN RED CEDAR, KILN DRIED, SELECTED KNOTTY GRADE, FASTENER: NAILS MUST BE LARGE HEAD, CORROSION RESISTANT, (ELECTRO-GALVANIZED, HOT DIPPED GALVANIZED, BEVELED OR CHANNEL PATTERN, PRE-STAINED. ALUMINUM), ROOFING NAILS. FIBBER CEMENT EXTERIOR SIDING: NON COMBUSTIBLE FIBBER REINFORCED CEMENT HORIZONTAL SIDING. METAL FLASHING: BASE AND COUNTER FLASHING AND COPING METAL TO BE SHEET STEEL, MINIMUM 26 GAUGE, EXTERIOR FASCIAS AND TRIM: No.2, S-P-F, TEXTURED (COMBED) FINISH, PRE PRIMED FOR SOLID COLOR GALVANIZED TO ASTM A525,ZF275 COATING, PRE FINISHED WITH STELCOLOUR 5000 SERIES PAINT FINISH. STAIN, NOT LESS THAN 2" (50MM) NOMINAL THICKNESS. STEP FINISHING MUST BE 26 GAUGE IN ACCORDANCE WITH RCABC REQUIREMENTS. SILL GASKET: CLOSED CELL POLYETHYLENE FOAM. ACCESSORIES: INSTALL ZINC. STRIPS TO ASPHALT SHINGLE AT ALL RIDGE LOCATIONS. INSTALL ZINC STRIP MUST GRAB BAR BLOCKING: 2" X 10" (38MM X 235MM). BE 2" (50MM) EXPOSED TO THE WEATHER. WOOD PRESERVATIVES: WOOD IN CONTACT WITH CONCRETE, MASONRY, AT ROOF UPSTANDS IN FLAT ROOFS, EAVES PROTECTION: SELF ADHESIVE RUBBERIZED ASPHALT SHEET INSTALLED TO BUILDING CODE REQUIREMENTS. PLANTERS, HEAVY TIMBER CONSTRUCTION, FENCE POSTS AND CAVITY FURRING: PRESSURE TREATED MINIMUM ACCEPTABLE MATERIALS AS LISTED IN RCABC ROOFING MANUAL TAB 2" ACCEPTABLE MATERIAL LIST", LATEST EDITION. 0.40 LB/FT2 TO CSA 080-M89, CLEAR, WATER BORNE, CHROMATE COPPER ARSENATE PRESERVERS BUREAU UNDERLAY: 1 PLY OF No. 15 NON PERFORATED ASPHALT FELT TO CSA A123.3M1979. (CWPB) STAMPS. BOTTOM PLATE OF FRAME WALLS WITH SILL GASKETS DO NOT REQUIRE PRESSURE TREATING. EXECUTION: ASPHALT SHINGLE ROOFING MUST BE INSTALLED ACCORD. TO RCABC,STR-LS FOR LOW SLOPE ROOFS. INSTALL UNDERLAY ON ALL ROOF DECKS WHERE ASPHALT SHINGLES OF ANY TYPE ARE TO BE INSTALLED. USE HEM-FIR OR PINE INCISED LUMBER FOR TREATMENT. B UNDERLAY TO BE MINIMUM 1 PLY OF No. 15 NON PERFORATED FELT, LAPPED MINIMUM 3"(75MM) OR THE TREAT CUT SURFACES WITH TWO BRUSH OF COPPER NAPTHANATE PRESERVATIVE. 7-7 SPECIFIC SHINGLE MANUFATURER'S. EXECUTION: EXTERIOR WALL SILL PLATES: SET EXTERIOR WALL SILL PLATES ON FULL WIDTH STRIP OF RECOMMENDED UNDERLAY. THIS UNDERLAY IS ADDITIONAL TO ANY MATERIAL USED FOR EAVES PROTECTION AND SHOULD BE LAPPED OVER THE LEADING (TOP) EDGE OF THE EAVES PROTECTION. FASCIA WINDOW TRIM, TRIM: INSTALL FASCIAS AND TRIMS IN LONGEST PRACTICAL LENGTHS, END JOINTS PROVIDE SLOPE TO DRAIN IN ALL GUTTER APPLICATIONS. WATERPROOF LINING FOR "HIDDEN" OR "INBOARD" OR TO BE CUT IN 45 DEGREES AND LAPPED. PLY FULLY TORCHED TO FIRST PLY. FASTEN WITH HOT DIPPED GALVANIZED CASING NAILS AND COUNTERSINK. "BUILT-IN" TYPE GUTTERS MUST BE FULLY ADHERED 2 PLY MODIFIED BITUMEN SHEETS AND MUST THE BASE SHEET WOOD SIDING: INSTALL WALL CAVITY IF REQUIRED BY WALL DESIGN. INSTALLED UP THE SLOPE OF THE ROOF A MINIMUM OF 18" (450MM) HIGHER THAN TOP OF OUTBOARD SIDE USE LONGEST POSSIBLE LENGTHS TO MINIMIZE END JOINTS. ELEVATION OF THE GUTTER. THE CAP SHEET IS TO PROVIDE UV PROTECTION AND MUST BE INSTALLED IN ALL INSTALL SIDING USING GALVANIZED SIDING OR CASING NAILS WITH RING OR SPRING SHANKS. AREAS EXPOSED TO U.V. USE SELF ADHERING BASE SHEET WHENEVER POSSIBLE WITH SECOND UV PROTECTIVE DO NOT NAIL THROUGH OVERLAPPING PIECES. ENSURE DRAINS DISCHARGE INTO DOWN SPOTS THAT ARE KEPT ABOVE FREEZING. NAILS MUST BE LONG ENOUGH THAT THE NAIL PENETRATES THE FRAMING AT LEAST 1 1/4" (31.7MM). LAP BEVEL SIDING A MINIMUM OF 1" (25.4MM). SHIM BOTTOM EDGE OF SIDING TO PROVIDE A 1/8" (3MM) GAP BETWEEN IT AND THE SIDING BELOW. NOTES FOR ROOF SPACE VENTILATION USE SOLID TRIMS AT INSIDE AND OUTSIDE CORNERS. BUTT SIDING INTO TRIMS. USE SOLID WOOD TRIMS AT THE INSIDE AND OUTSIDE CORNERS. BUTT SIDING INTO TRIMS. 1. UNIFORMLY DISTRIBUTE VENTILATION TO FLAT AND VAULTED ROOFS TO 1/150 OF INSULATED CEILING AREA. 2. PROVIDE 2x2 CROSS PURLINS TO FLAT, VAULTED CEILINGS AND DECKS OVER LIVING AREAS. SECTION 07200

DN

9'-421"

5026RS

SECTION 06100

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

1. ROOF FINISH: ASPHALT SHINGLE 2. EXTERIOR WALL FINISH: FINISH STUCCO , NATURAL OR CULTURED STONE

3068

EXTERIOR BUILDING FINISH MATERIALS:

A 7-7

BOUNDARY OF LEGAL SUITE NEW CHANGES

11'-712"

2'-6"

4'-221"

7'-11"

13'-9"

40'-0"

PROVIDE MIN. 2-1/2" CLEARANCE BETWEEN ROOF SHEATHING AND INSULATION. PROVIDE MIN. 1" CLEARANCE BETWEEN TOP OF ROOF JOIST AND INSULATION. VENTILATE ATTIC SPACES TO 1/300 OF INSULATED CEILING AREA. ROOF VENTS MUST BE UNIFORMLY DISTRIBUTED WITH A MIN. OF 25% IN EAVES AND 25% IN ROOF TOP. PROVIDE ATTIC ACCESS OF 1'-8" X 2'-4" AND WEATHER-STRIP HATCH.

BASEMENT FLOOR PLAN SCALE: 14" = 1'-0"

NOTE: WALL FOOTING SIZE - 22"x8": PROVIDE 2-15M LONGITUDINAL @3" CLEAR COVER FROM BOTTOM

8' - 0 34" HIGH CEILING

FOUNDATION WALL - 8" PROVIDE 15M@ 16" o.c. EACH WAY C/W 1.5" CLEAR COVER FROM INSIDE FACE OF WALL

FLOOR AREA: SECONDARY SUITE: BSMT. WELL:

F1 - 36" x 36" x 10" CONC. PAD FOOTING 3-15M EACH WAY AT 3" CLEAR COVER FROM BOTTOM

CLIENT:

SHEET TITLE:

MR.DOM PINEDA PROJECT: CIVIC ADDRESS:8066 -18TH AVE, BURNABY, BC

Basement Floor Plan

1190 SQ FT 594 SQ FT 131 SQ FT

DRAWN BY:

G.S.B

PROJECT NO.

CHECKED BY:

B.M.

239

DATE:

SEP. 2016

FILE NO.

SCALE:

1/4"=1'-0"

V14

SHEET NO:

A

2/6


A 7-7

A 7-7

38'-0" 38'-0"

11'-214"

3'-1014"

4'-4"

DN

3'-314"

5080

2850RS

2850RS

5040RS

6'-6"

1'-11"

5'-0"

2'-512"

5'-0"

11'-1034"

5040RS

3040RS

5068

3040RS

3'-121"

16'-0"

15'-7"

SMOKE ALARM & CARBON MONOXIDE (CO) ALARM

2668

3'-1121"

2'-0" O.H.

10'-9"

2850RS

2'-721"

5'-114"

26'-6"

3'-412"

2668

2668

ATTIC ACCESS 2'-0"X2'-3" 10'-6" 10'-0" 5'-0"

2668

3030RS

DORMER

4'-734"

B 7-7

10'-0"

2030SH

3'-1014"

4'-614"

2'-0" O.H.

8'-6" 5'-8"

4040RS

5'-6"

2'-221"

3040RS

4'-2"

2668 2668

6'-921"

24'-11"

5'-1121"

2668

2668 2030RS

4'-3"

40'-6"

8'-312"

7'-021"

4020RS

2'-414" 2'-714"

4'-1112" 6'-921"

11'-1021"

2668

8070TC

3'-0" HIGH GUARD RAIL(TYP.)

1'-334"

5'-6"

6'-334"

6'-514"

3'-6"

2830RS 5'-912"

DN

6'-121"

6'-2"

6'-5"

6'-0"

40'-0"

4'-121" 8'-0"

40'-0"

6'-912"

6'-1121" 13'-9"

MAIN FLOOR PLAN

SECOND FLOOR PLAN

SCALE: 14" = 1'-0"

SCALE: 14" = 1'-0"

9' - 0 34" HIGH CEILING

8' - 0 34" HIGH CEILING

FLOOR AREA: 1554 SQ FT. FRONT PORCH: 39 SQ FT. DECK AREA: 228 SQ FT

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

2830LS

18'-1"

8R@7"

3'-1021"

18'-3"

2'-0" O.H.

8070TC

1'-334"

1'-3"

window seat

4'-0"

2'-0"

5'-0"

3'-0"

5080

window seat 8040TC

4'-0"

2'-0"

2'-0"

4'-3"

8'-6"

1'-5"

18R@7 14" 17T@10" DN

16'-812"

5'-2"

4068

5040RS

2'-7"

5'-1"

3'-921"

2668

8'-0"

WINDOW SEAT 18" HIGH

5'-721"

2'-521"

2668

B 7-7

9'-021"

36" HIGH HANDRAIL

1'-0"

5'-3"

40'-6"

5040RS

6'-734" UP

10'-1021"

36'-6"

3'-10"

3030RS 3'-1121"

40'-6"

18R@7 1/2" 17T@10"

2868

2'-721"

2668

5068

1'-1114"

2'-1"

1568

4'-4"

4'-4"

4'-1014"

6'-314"

2868 3'-512"

21068

2668

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

10'-1034"

3040RS

3'-6" high guard rail

3'-6" high guard rail

1656RS 2680

5'-514"

3'-3"

14'-412"

13'-1"

8'-10"

9'-321"

4'-1"

1'-11"

10'-621"

7068

DN

2'-0"

5R @ 7"

19'-9"

11'-1034"

15'-514"

6'-0"

2'-934" 5R @ 7"

CLIENT:

FLOOR AREA: 1199 SQ FT DECK AREA: 87 SQ FT

SHEET TITLE:

MR.DOM PINEDA PROJECT: CIVIC ADDRESS:8066 -18TH AVE, BURNABY, BC

Main & Upper Floor

DRAWN BY:

G.S.B

PROJECT NO.

CHECKED BY:

B.M.

239

DATE:

SEP. 2016

FILE NO.

SCALE:

1/4"=1'-0"

V14

SHEET NO:

A

3/6


6'-014" [1.83m]

ROOF RIDGE LVL. 387.64

U/S CEILING LVL. 381.62

12

1

5 12 5

3

9 9

MATERIAL SPECIFICATIONS

8' [2.44m]

2

10

12

8

4 5 6

9

11'-23 8" [3.41m]

12 10

6

ASPHALT SHINGLE 40 YRS - IKO CAMBRIDGE, DUAL BLACK

2.

BUILT-IN GUTTER - METAL SOFFIT WITH 2" CONTINUOUS SCREENED VENT

3.

1 x 4 OVER 1 x 6 ON 2" X 10" FASCIA BOARD

4.

1" X 4" WOODEN TRIM AND 4" MOULDING ALL AROUND

5.

STUCCO

6.

ALUMINUM FRAMED WINDOW AND PATIO DOOR

7.

WOODEN EXTERIOR DOOR

8. 9.

STONE OR STUCCO CEDAR

8

5

7

8

AVE. GRADE. LVL. 358.1

9'-23 8" [2.80m]

MAIN FL. LVL. 362.42

E.EL. 358.1 P.EL. 358.5

E.EL. 358.5 P.EL. 358.5

CELLAR. LVL. 353.22 ROOF RIDGE LVL. 387.64

FRONT ELEVATION (NORTH)

12

6'-014" [1.83m]

scale: 14" = 1'-0"

5

8' [2.44m]

U/S CEILING LVL. 381.62

3'-6" HIGH GAURD RAIL (TYP.)

11'-23 8" [3.41m]

SECOND FLOOR LVL. 373.62

RIGHT / WEST ELEVATION TOTAL AREA: 789 SQ. FT. ( 73.30 SQ.M.) DISTANCE TO PROPERTY LINE: 4'-9" (1.45 M) ≈ 1.5M MAX. ALLOWABLE UNPROTECTED AREA @ 8.0% = 65.26 SQ. FT. PROPOSED UNPROTECTED AREA: 64.5 SQ. FT

" 3'-0

MAIN FL. LVL. 362.42

AVE. GRADE. LVL. 358.1

8

H

HIG

D HAN

3'-6" HIGH GAURD RAIL (TYP.)

L RAI

9'-23 8" [2.80m]

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

SECOND FLOOR LVL. 373.62

1.

3'-0

"H 3'-0 IGH H " hig AND h ha RA nd IL rail

E.EL. 358.4 P.EL. 358.5 E.EL. 358.1 P.EL. 358.5

RIGHT ELEVATION (WEST) scale: 14" = 1'-0"

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CELLAR. LVL. 353.22

CLIENT:

SHEET TITLE:

MR.DOM PINEDA PROJECT: CIVIC ADDRESS:8066 -18TH AVE, BURNABY, BC

Front & right side elevation

DRAWN BY:

G.S.B

PROJECT NO.

CHECKED BY:

B.M.

239

DATE:

SEP. 2016

FILE NO.

SCALE:

1/4"=1'-0"

V14

SHEET NO:

A

4/6


scale: 14" = 1'-0"

6'-014" [1.83m]

ROOF RIDGE LVL. 387.64 12 5

8' [2.44m]

U/S CEILING LVL. 381.62

3'-6" HIGH GAURD RAIL (TYP.) 12 4

12

11'-23 8" [3.41m]

10

3'-6" HIGH GAURD RAIL (TYP.)

AVE. GRADE. LVL. 358.1

9'-23 8" [2.80m]

MAIN FL. LVL. 362.42

E.EL. 358.4 P.EL. 358.5

E.EL. 357.7 P.EL. 358.5

CELLAR. LVL. 353.22

REAR ELEVATION (SOUTH)

ROOF RIDGE LVL. 387.64

= 1'-0"

12

6'-014" [1.83m]

scale: 14"

5

8' [2.44m]

U/S CEILING LVL. 381.62

3'-6" HIGH GAURD RAIL (TYP.)

12

SECOND FLOOR LVL. 373.62

10

11'-23 8" [3.41m]

LEFT / EAST ELEVATION TOTAL AREA: 913 SQ. FT. ( 84.82 SQ.M.) DISTANCE TO PROPERTY LINE: 5'-0" (1.5 M) ≈ 1.5M MAX. ALLOWABLE UNPROTECTED AREA @ 8.0% = 65.86 SQ. FT. PROPOSED UNPROTECTED AREA: 64 SQ. FT (4.55 SQ. M.)

3'-0

3'-6" HIGH GAURD RAIL (TYP.)

hig '-0"

3

MAIN FL. LVL. 362.42

AVE. GRADE. LVL. 358.1

9'-23 8" [2.80m]

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

SECOND FLOOR LVL. 373.62

"H 3'-0 IGH H " hig AND h ha RA nd IL rail

il d ra

n

h ha

3'-6" HIGH GAURD RAIL (TYP.)

E.EL. 357.7 P.EL. 358.5

E.EL. 358.5 P.EL. 358.5

LEFT ELEVATION (EAST) scale: 14" = 1'-0"

CELLAR. LVL. 353.22

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

SHEET TITLE:

MR.DOM PINEDA PROJECT: CIVIC ADDRESS:8066 -18TH AVE, BURNABY, BC

Side Elevations

DRAWN BY:

G.S.B

PROJECT NO.

CHECKED BY:

B.M.

239

DATE:

SEP. 2016

FILE NO.

SCALE:

1/4"=1'-0"

V14

SHEET NO:

A

5/6


ROOF RIDGE LVL. 387.64

1 6'-014" [1.83m]

12 5 ATTIC VENTILATION AS PER BUILDINGCODE A/300 OF INSULATED CEILING AREA MIN. 25% OF VENTING @TOP & 25% @ BOTTOM

DUROID ROOF BUILDING PAPER ON 12" PLYWOOD ENG.TRUSSES @24" O/C R-40 BATT INSULATION 6 MIL POLY V.B. (LAPPED JOINTS,SEAL ELECT. OUTLETS) (WARM SIDE) 5 8" GYPSUM BOARD BUFFLES 2" CLEAR FROM TOP

SECTIONAL DETAILS AND SPECIFICATIONS:

U/S CEILING LVL. 381.62

1 2

- ROOF FINISH: 210 # ASPHALT SHINGLES ROOF - STARTER STRIP - 716" OSB SHEATHING c/w. H. CLIPS - PREFAB. ENG. TRUSSES @ 24" O.C. - R-50 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.

8' [2.44m]

3 TYP.CELLAR FLR. ASSEMBLY GYPSUM BOARD FLR. JOINTS @ 16" o.c. AS ER STRUC. ENG. 5 " T&G PLYWOOD SUBFLOOR 8 RADIANT HEATING PIPES ON WIRE MESH 1- 12" LIGHT WEIGHT CONC. TOPPING FLOOR FINISH 1" 2

SECOND FLOOR LVL. 373.62

3'-6" HIGH GUARD RAIL (TYP.)

5

112" CONC. TOPPING

2

6

11'-23 8" [3.41m]

TYP.CELLAR FLR. ASSEMBLY GYPSUM BOARD FLR. JOINTS @ 16" o.c. AS ER STRUC. ENG. 5 " T&G PLYWOOD SUBFLOOR 8 RADIANT HEATING PIPES ON WIRE MESH 1- 12" LIGHT WEIGHT CONC. TOPPING FLOOR FINISH

INTERIOR PARTITIONS ( 1 hr FRR):

4

1" 2

" 3'-0

MAIN FL. LVL. 362.42

ha high

rail

3'-6" HIGH GUARD RAIL (TYP.) 5 " ANCHOR BOLTS @ 36" 8 O.C.(TYOP)

112" CONC. TOPPING

5

3'-0

" HI

GH

HAN DR

7

9'-23 8" [2.80m]

2-15M CONTINUOUS

FOUNDATION WALLS: - 2 x 6 SILL PLATE - 8" CONC. FOUNDATION WALL - 2 COATS OF ASHPALT EMULSION TO EXTERIOR FACE - 2 - 15M T & B, 10M @16" O.C E/W.1.F UP TO GRADE

EXTERIOR WALLS (2 hr FRR): - STUCCO ON WIREMESH - METAL LATH - 19MM (3/4") AIR SPACE / @ 16" O.C. - 15# BREATHER TYPE BUILDING PAPER - 15 32" SHEATHING - 2 x 6 STUDS @ 16" O.C. - R-20 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.

AIL

BASEMENT FLOOR: - FINISH FLOOR: TO OWNERS SPEC'S - 0'-6" CONC. SLAB - 10 GA 6 x 6 WIRE MESH - 6 MIL. POLY. V.B. - R-10 RIGID INSULATION - MIN. 12" COMPACTED GRANULAR FILL

- 1/2" GYPSUM BOARD (BOTH SIDES) - 2 x 4 STUDS @ 16" O.C. - INSUALTED CAVITY

nd

INTERNAL INSULATED WALL - 2" AIR SPACE - 2 x 4 SPF # 2 STUDS @ 24" O.C. (U.N.O.) - R-14 BATT. INSULATION - 6 MIL. POLY. V.B. - C/W TUCK TAPE JOINTS - 1/2" DRYWALL

7 DAMPROOFING

6

6'-014" [1.83m]

1

A

B

LESS THAN 7'-6"

0"

0"

7'-6" TO 8'-0"

18"

20"

8'-1" TO 9'-0"

14"

20"

9'-1" TO 10'-0"

12"

20"

NOTE: 1. REBAR TO BE 230 MPa MINIMUM. 2. CONCRETE TO BE 20 MPa MINIMUM. 3. BACKFILL NOT TO EXCEED 20 KN/ cubic METER

TYPICAL FLOOR CONSTRUCTION

2" FROM GARAGE SLAB OR SIDEWALK 8" MIN. FROM FINISH GRADE GARAGE SLAB OR FINISHED GRADE

W1(C): -38mm(112")X 89mm(321") STUDS SPACED 400mm OR 600mm -WITH 89mm THICK ABSORPTIVE MATERIAL -15.9mm(5 8") TYPE X GYPSUM BOARD

MAX. COVER 2" HORIZONTAL STEEL = 'B' (LAP JOINTS 18" MINIMUM) APPLY DAMPROOFING AS REQ. BY N.B.C. SECT.9-13 4" CONC. SLAB ON 6 MIL. POLY. V.B. ON 6" COMPACTED GRANULAR FILL

NET BACKFILL HEIGHT

VERTICAL STEEL = 'A' (ALTERNATE HOOKS)

ON PLAN

8"

2-15M CONT. AS NOTED ON PLAN

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

5

8" TYPE "X" GYPSUM BOARD ON BOTH SIDES CONTINUOUS TO UNDERSIDE OF FLOOR SHEATHING (HATCHED AREA)

W1(C): -38mm(121")X 89mm(312") STUDS SPACED 400mm OR 600mm -WITH 89mm THICK ABSORPTIVE MATERIAL -15.9mm(5 8") TYPE X GYPSUM BOARD

8"

TYPE "X" GYPSUM BOARD AGAINST SEPARATION WALL

DETAIL AT 'A'

TYP.CELLAR FLR. ASSEMBLY GYPSUM BOARD FLR. JOINTS @ 16" o.c. AS ER STRUC. ENG. 112" CONC. TOPPING 5 8" T&G PLYWOOD SUBFLOOR RADIANT HEATING PIPES ON WIRE MESH 1- 12" LIGHT WEIGHT CONC. TOPPING FLOOR FINISH 1" 2

SECOND FLOOR LVL. 373.62

F.R.R WALL DETAIL

-METAL FURRING CHANNELS SPACED 600mm O.C. -15.9mm (58") TYPE X GYPSUM BOARD

F.R.R. CEILING DETAIL

AVE. GRADE. LVL. 358.1

PROJECT: CIVIC ADDRESS:8066 -18TH AVE, BURNABY, BC

5

8" ANCHOR BOLTS @ 36" O.C.(TYOP)

2-15M CONTINUOUS DAMPROOFING

7 DRAIN TILE 2-15M CONTINUOUS

6

CELLAR. LVL. 353.22

DRAIN TILE 2-15M CONTINUOUS

B 6-6

SHEET TITLE:

MR.DOM PINEDA

TYP.CELLAR FLR. ASSEMBLY GYPSUM BOARD FLR. JOINTS @ 16" o.c. AS ER STRUC. ENG. 5 " T&G PLYWOOD SUBFLOOR 8 RADIANT HEATING PIPES ON WIRE MESH 1- 12" LIGHT WEIGHT CONC. TOPPING FLOOR FINISH

5

scale: 14" = 1'-0"

CLIENT:

VAULTED CEILING

1" 2

SECTION AT

SUPPORTED WALL SECTION

5

4

MAIN FL. LVL. 362.42

F5(D): -SUBFLOOR OF 15.5mm PLYWOOD, OSB OR WAFERBOARD OR 17mm TONGUEAND GROOVE LUMBER -38mm(112")X 235mm(914") WOODFLOOR JOISTS -ABSORPTIVE MATERIAL IN CAVITY -METAL FURRING CHANNELS SPACED 600mm O.C. -15.9mm(85") TYPE X GYPSUM BOARD

DUROID ROOF BUILDING PAPER ON 12" PLYWOOD ENG.TRUSSES @24" O/C R-40 BATT INSULATION 6 MIL POLY V.B. (LAPPED JOINTS,SEAL ELECT. OUTLETS) (WARM SIDE) 5 8" GYPSUM BOARD BUFFLES 2" CLEAR FROM TOP

3

FLOOR JOIST

NOTCH OUT 21" TYPE "X" GYPSUM BOARD FOR FLOOR JOISTS

15M @ 15" o.c.

4"Ø PERIMETER DRAIN TILE WITH DRAIN ROCKS

A

SUBFLOOR

5

12 10

2

30 MIN. F.R.R. ASSEMBLY DETAIL

212" RIGID INSULATION (N.I.C.) TO BELOW FROSTLINE OR 2x4 FURRED WALL w/ R12 F.G. BATT INSUL. (N.I.C.) WHERE INDICATED

8" REINFORCED CONCRETE FOUNDATION WALL

U/S CEILING LVL. 381.62

SECTIONAL DETAILS AND SPECIFICATIONS:

EXTERIOR WALL CONSTRUCTION 5 8" ANCHOR BOLT @ 48" o.c. (MAX. OF 1 PLATE UNDER JOIST.)

ATTIC VENTILATION AS PER BUILDINGCODE A/300 OF INSULATED CEILING AREA MIN. 25% OF VENTING @TOP & 25% @ BOTTOM

4' [1.22m]

NET BACKFILL HT.

12 5

8' [2.44m]

F5(D): -SUBFLOOR OF 15.5mm PLYWOOD, OSB OR WAFERBOARD OR 17mm TONGUEAND GROOVE LUMBER -38mm(121")X 235mm(914") WOODFLOOR JOISTS -ABSORPTIVE MATERIAL IN CAVITY -METAL FURRING CHANNELS SPACED 600mm O.C. -15.9mm(58") TYPE X GYPSUM BOARD

SUPPORTED WALL (10M BAR)

24"

ROOF RIDGE LVL. 387.64

11'-23 8" [3.41m]

scale: 14" = 1'-0"

A 6-6

9'-23 8" [2.80m]

SECTION AT

DRAIN TILE 2-15M CONTINUOUS

3'-314" [1.00m]

CELLAR. LVL. 353.22

AS NOTED

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

- 5 8" TYPE "X" GYPSUM BOARD (FIN. AS PER OWNER)

EAVES:

3

MAIN FLOOR (1 hr FRR): - FINISH FLOOR: TO OWNERS SPEC'S - P.T. 2x10 @16 o.c. JOISTS AS PER MANUFACTURERS SPECS - 11/2"th. CONCRETE TOPPING - R-40 SPRAT FOAM INSULATION

- BUILT-IN GUTTER - 2 x 12 FASCIA BOARD - METAL SOFFIT WITH 2" CONTINUOUS SCREENED VENT

4

AVE. GRADE. LVL. 358.1

5

ROOF:

SECTIONAL DETAILS

DRAWN BY:

G.S.B

PROJECT NO.

CHECKED BY:

B.M.

239

DATE:

SEP. 2016

FILE NO.

SCALE:

1/4"=1'-0"

V14

SHEET NO:

A

6/6


BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

∙

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

SHEET TITLE:

MR.DOM PINEDA PROJECT: CIVIC ADDRESS:8066 -18TH AVE, BURNABY, BC

ENERGY DETAIL

DRAWN BY:

G.S.B

PROJECT NO.

CHECKED BY:

B.M.

239

DATE:

SEP. 2016

FILE NO.

SCALE:

N.T.S.

V13

SHEET NO:

A


GRID

GRID

HEADER

EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

SEAL POLYETHYLENE (A.B. & V.B.) TO HOUSEWRAP (A.B.) 1/2"CONTROL JOINT FLOOR FINISH ON C/W CAULK AND ROD CONCRETE TOPPING

MIN. 3/8" GAP BETWEEN WINDOW & 1X2 STRAPPING

EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

4" ADHERED FLASHING MEMBRANE

INTERIOR

100 mm (4")

FLOOR FINISH ON CONCRETE TOPPING

SHEATHING PAPER BEHIND FLASHING AND INTO WINDOW OPENING INSECT SCREEN

MIN. 2% SLOPE TO DRAIN SEALANT JOINT AT VENT DUCT TO HOUSEWRAP (A.B.)

2"CONTINUOUS FLANGE AT PERIMETER OF HOOD

ROD AND SEALANT STUD @ 16" O.C

2"

2

SEALANT OR GASKET (A.B.) BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED

1 MIN 2"

BLDG. PAPER

4.06

23.03

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

3.99

22.61

0.68

4.11

23.29

ADHERED MEMBRANE FLASHING TO LAP 100mm (4") OVER SHEATHING PAPER BELOW

ROOF ASSEMBLY COMPONENTS (W/ ASPHALT SHINGLES) 1 ROOFING SHINGLES 2 POLYTHENE V.B 5 ″ (15.88 MM) OSB SHEATHING 3 8 4 2 x 10 JOISTS W/ R50 BATT @ 24″ O.C. 5 POLYETHYLENE 6 1/2″ (12.7 MM) GYPSUM BOARD 7 INTERIOR AIR FILM

RSI 0.077 0.00 0.136 8.8 0.00 0.08 0.12

R 0.44 0.00 0.77 50.0 0.00 0.45 0.68

SEALANT OR GASKET JOINT AT POLYETHYLENE (A.B. & V.B.) TO PLATE (A.B.)

2X10 FLOOR JOISTS

SEAL POLYETHYLENE (V.B.) TO SHEATHING PAPER (A.B.)

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

9.21

50.34

FLOOR ASSEMBLY OVER UNHEATED SPACE 1 EXTERIOR AIR FILM 2 FLOOR FINISHES (3 4" HARDWOOD) 3 POLYETHYLENE 4 512" CONC. SLAB 5 R-28 INSULATION 9 NATURAL GRADE

RSI 0.03 0.12 0.00 0.15 4.99 0.00

R 0.17 0.68 0.00 0.83 28.00 0.00

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

5.29

29.68

TRIPLE GLAZED WINDOWS & DOORS LOW E, DOUBLE GLAZED (6mm GAP), TEMPERED GLASS εn = 0.1, AIR FILLED WITH VINYL OR FIBRE GLASS FRAME

USI

U

1.4

0.246

1" 2

SEPERATION AIR SPACE

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

1 MIN.

PREFINISHED METAL FLASHING C/W END DAMS TO EXTEND 1" PAST END OF WINDOW FRAME

VENTED ALUMINUM SOFFIT PANELS EFFECTIVE RSI - 4.06 SEAL SHEATHING PAPER (A.B.) TO WINDOW FRAME REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

VALUES ADOPTED FROM CANADIAN WOOD COUNCIL

VALUES ADOPTED FROM CANADIAN WOOD COUNCIL

1.5" SILL PLATE

BUILDING - INTERIOR DESIGNERS

EXTERIOR STUCCO CLADDING

- HEAVY- DUTY POLYVINYL CHLORIDE (PVC )

INTERIOR

AIR SPACE W/ 1x2 TREATED WOOD STRAPPING SCREWED THROUGH INSULATION

THERMOPLASTIC WATER PROOFING MEMBRANES ARE OVERLAPPED AND HEAT FUSED ( APPLICATION CODE :CGSB -37-GP-55M)

SEALANT OR GASKET POLYETHYLENE TO PLATE (A.B.)

FLASHING & COUNTER FLASHING

SEALANT OR GASKET (A.B.)

ASPHALT IMPREGNATED PAPER

INSECT SCREEN - NO DAMPERS

EFFECTIVE RSI VALUE = 6.06 ROOFING SHINGLES (M.B.) WATERPROOF ROOF MEMBRANE (M.B.) FOR EAVE PROTECTION 5/8" OSB ROOF SHEATHING W/ H CLIPS WOOD ROOF FRAMING R-50 BATT INSULATION POLYETHYLENE (A.B. & V.B.) GYPSUM BOARD

GRID

1/2″ (12.7 MM) PLYWOOD SHEATHING

2 X 2 BLOCKING AT BOTH ENDS OF VENT 11/2" CONT. VENT

POLYETHYLENE VAPOR BARRIER

ADHERE SUBFLOOR TO HEADER (A.B.) FLOOR FINISH ON CONCRETE TOPPING

EFFECTIVE USI VALUE - 1.4 OPERABLE VINYL OR FIBERGLASS FRAME LOW ENERGY, DBL. GLAZED TEMP. GLASS W/ SLOPED SILL WEATHER STRIPPING

EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 (RSI-1.06)

1/2″ (12.7 MM) GYPSUM BOARD

MIN. 2% SLOPE TO DRAIN

2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. SLOPED SUB-SILL FRAMING

SEALANT OR GASKET (A.B.) REFER TO W-1 FOR EXTERNAL WALL ASSEMBLY DETAIL

INSULATION GUARD

POLYETHYLENE (V.B. AND A.B.) SEALANT OR GASKET (A.B.)

EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

GASKET (A.B.)

BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED

LAP POLYETHYLENE AND SEAL TO ADHERED MEMBRANE (A.B. AND V.B.)

W-1

SEALANT AND BACKER ROD JOINT AT WINDOW FRAME TO MEMBRANE (A.B. AND M.B.) SEALANT FILLET JOINT PREFINISHED METAL DRIP FLASHING

SEALANT BETWEEN POLYETHYLENE AND HOUSEWRAP (A.B.) FLOOR FINISH ON CONCRETE TOPPING

INTERMITTENT 1/8" P.T. SHIM BEHIND WINDOW FLANGE TO CREATE DRAINAGE PATH (ALTERNATELY DRILL HOLES OR SLOTS THROUGH WINDOW FLANGES TO TO ALLOW FOR DRAINAGE)

HOUSEWRAP AT HEADER (A.B.)

BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED GYPSUM BOARD

BATT INSULATION POLYETHYLENE (V.B.) STAPLED IN PLACE

25mm (1")

ADHERED MEMBRANE FLASHING (M.B.) SILL GASKET (A.B.)

CEMENT OR ACRYLIC STUCCO PARGING

EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

8" CONC. FOUNDATION WALL

FINISHED GRADE

4" EXTRUDED POLYSTYRENE R-5/in. 1" 2

REFER TO W-2/A-501 FOR FND WALL ASSEMBLY DETAIL

DRYWALL FINISH

912"

INSECT SCREEN

SEE 'FLASHING-BEST PRACTICE GUIDE' FOR ADDITIONAL ROOF FLASHING DETAILS

DAMP PROOFING / VAP. BARRIER

1/2"

2" MIN.

FILTER CLOTH

VENTED ALUMINUM SOFFIT PANELS

FLOOR OVER UNHEATED SPACE EFFECTIVE RSI 2.06

512"

CEMENT OR ACRYLIC STUCCO PARGING

8" MINIMUM

SHEATHING PAPER TO LAP OVER ADHERED MEMBRANE FLASHING

EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

SEAL HOUSEWRAP (A.B.) TO FRAMING

CONTINUE EAVE PROTECTION 12" BEYOND INSIDE FACE OF WALL

ADHERED MEMBRANE FLASHING TO EXTEND 4" AND LAP OVER SHEATHING PAPER

INTERIOR

COMPLETE W/ 4" EXTRUDED POLYSTYRENE FOAM BOARD INSUL. R-5/in.

WOOD FRAMING (STUDS OR STRAPPING)

W-2 UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

SHEET TITLE:

MR.DOM PINEDA PROJECT: CIVIC ADDRESS:8066 -18TH AVE, BURNABY, BC

GENERAL DETAIL

RSI R 0.03 0.17 0.035 0.20 1.06 6.00 0.00 0.00 0.11 0.62 2.55 14.49 0.00 0.00 0.08 0.45 0.00 0.00 0.12 0.68 .12

2a

2 SEALANT OR GASKET (A.B.)

EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

12mm (1/2")

SEAL POLYETHYLENE (A.B. & V.B.) TO HOUSEWRAP (A.B.)

1X2 STRAPPING

UDC DESIGN CENTER LTD

4" FLANGE

25.4mm (1")

R 0.17 0.62 6.00 0.00 0.62 14.49 0.00 0.45 0.00 0.68

WALL ASSEMBLY COMPONENTS (W/ STUCCO CLADDING) 1 EXTERIOR AIR FILM 3 " STUCCO FIN. 2 4 3 EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 4 ASPHALT IMPREGNATED PAPER2 5 1/2″ (12.7 MM) PLYWOOD SHEATHING 6 2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. 7 POLYETHYLENE 8 1/2″ (12.7 MM) GYPSUM BOARD 9 FINISH: 1 COAT LATEX PRIMER AND LATEX PAINT 10 INTERIOR AIR FILM

SHEATHING PAPER TO LAP METAL FLASHING

ROD AND SEALANT 1

RSI 0.03 0.11 1.06 0.00 0.11 2.55 0.00 0.08 0.00 0.12

VALUES ADOPTED FROM CANADIAN WOOD COUNCIL

4" FLANGE 6

WALL ASSEMBLY COMPONENTS (W/ NINYL CLADDING) 1 EXTERIOR AIR FILM 2 VINYL SIDING (NO AIR SPACE) 3 EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 4 ASPHALT IMPREGNATED PAPER 5 1/2″ (12.7 MM) PLYWOOD SHEATHING 6 2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. 7 POLYETHYLENE 8 1/2″ (12.7 MM) GYPSUM BOARD 9 FINISH: 1 COAT LATEX PRIMER AND LATEX PAINT 10 INTERIOR AIR FILM

EXTERIOR

4"

EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

RSI / R VALUE CALCULATIONS FOR ASSEMBLIES

EFFECTIVE USI VALUE - 1.4 OPERABLE VINYL OR FIBERGLASS FRAME LOW ENERGY, DBL. GLAZED TEMP. GLASS W/ SLOPED SILL WEATHER STRIPPING

GRID

DRAWN BY:

G.S.B

PROJECT NO.

CHECKED BY:

B.M.

239

DATE:

SEP. 2016

FILE NO.

SCALE:

N.T.S.

V13

SHEET NO:

B


SPECIFICATIONS AND GENERAL NOTES:

BUILDING SPEC. LIST:

EXTERIOR BUILDING FINISH MATERIALS:

1. ROOF (TRUSS):

1. ROOF FINISH: ASPHALT SHINGLE 2. EXTERIOR WALL FINISH: FINISH STUCCO , NATURAL OR CULTURED STONE

7. UPPER FLOOR:

1HR. FIRE RATED FOR WALLS AND CLG.

3. EXTERIOR WINDOWS: ALUMINUM CLADDED WOOD FRAME OR VINYL FRAME 4. WINDOW TRIMS: HARDITRIM 5. SOFFITS: VENTED HARDISOFFIT

2. CEILING:

GENERAL NOTES

SECTION 07200

123456-

VAPOR BARRIER / VAPOR RETARDER PRODUCT: MATERIAL TO CONFORM TO CAN2-51.33-M80, TYPE II, 6 MIL IN WALLS. EXECUTION: APPLY VAPOR BARRIER TO WARM SIDE (INTERIOR SIDE) OF INSULATED WALLS. INSTALL VAPOR BARRIER TO PROTECT THE ENTIRE WALL SURFACE, INCLUDING FRAMING MEMBERS. APPLY VAPOR BARRIER HORIZONTALLY TO WALLS. LAP JOINTS MINIMUM OF 4" (100MM). SEAL TO FRAMING WITH ADHESIVE OR PRESSURE SENSITIVE TYPE. SEAL VAPOR BARRIER RETARDER TO PENETRATIONS.

78-

WATERPROOF WALLBOARD REQUIRED AS TILE BASE AROUND TUBS AND SHOWERS AS PER BCBC 9.29.10.4. CEILING AND WALLS TO HAVE 6 mil U.V.POLY FULLY CAULKED AS PER BCBC 9.25.2.3 5/8" DRYWALL REQUIRED TO CEILING MEMBERS AT 24" O.C. AS PER BCBC 9.29.5.3. PROVIDE 5" GRAVEL AS PER BCBC 9.14.4.2 AND 6 mil U.V.POLY AS PER BCBC 9.13.6 UNDER SLAB A BOND BREAKING MATERIAL IS REQUIRED BETWEEN FOUNDATION AND SLABS DOORS BETWEEN GARAGE AND DWELLING TO BE A SOLID CORE, SELF CLOSING, WEATHER STRIPPED DOOR AS PER BCBC 9.10.13.15. THICKEN SLAB AT GARAGE ENTRY AS PER STRUCTURAL DRAWINGS. HEATING SYSTEM IS RADIANT HEAT FOR ALL FLOORS

11- PRIOR TO FRAMING AND INSPECTION SUBMIT MECHANICAL VENTILATION/AIR CONDITIONING AND LETTER OF SUPERVISION B PROF.ENG.OR CERTIFIED H.R.A.I OR HVC TECHNICIAN. 12 - DWELLING SECURITY AS PER # 9.6.8 13 - PROVIDE FLASHING BETWEEN HORIZONTAL INTERSECTION OF DIFFERING WALL FINISHES.

SECTION 06100 ROUGH CARPENTRY

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

9- ENGINEERED ROOF TRUSS DESIGN REQUIRED PRIOR TO INSTALLATION. 10- PROVIDE 8" CLEARANCE BETWEEN GRADE AND SIDING.

LUMBER GRADES: AS SHOWN ON THE DRAWINGS AND / OR ACCORDING TO NLGA STANDARD GRADING RULES FOR CANADIAN LUMBER, MAXIMUM MOISTURE CONTENT 19%. ROOF SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR, METAL "H" CLIPS TO SUPPORT EDGES: 1/2" (12.5MM) FOR 16" (400MM) O/C SUPPORT; 5/8" (15.9MM) FOR 24" (600MM) O/C SUPPORT. INTERIOR FLOOR SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR OR SPRUCE. USE TO PLYWOOD WHERE REQUIRED BY STRUCTURAL DESIGN. FLOOR UNDERLAY: THREE PLY, 11/32" (8.5MM) THICK, SPRUCE PLYWOOD WITH THE FINISH FACE DOUBLE SANDED AND THE BACK FACE SLIGHTLY SANDED. THE CONTRACTOR MUST CONFIRM PRIOR TO INSTALLATION THE FLOORING UNDERLAY THAT IT IS ACCEPTABLE TO THE RESILIENT FLOORING MANUFACTURER. EXTERIOR DECK SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR, T&G. USE SELECT TIGHT FACE PLYWOOD UNDER PVC DECK WATERPROOFING. EXTERIOR WALL SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR OR SPRUCE. WOOD SIDING IF REQUIRED IN DESIGN: WESTERN RED CEDAR, KILN DRIED, SELECTED KNOTTY GRADE, BEVELED OR CHANNEL PATTERN, PRE-STAINED. FIBBER CEMENT EXTERIOR SIDING: NON COMBUSTIBLE FIBBER REINFORCED CEMENT HORIZONTAL SIDING. EXTERIOR FASCIAS AND TRIM: No.2, S-P-F, TEXTURED (COMBED) FINISH, PRE PRIMED FOR SOLID COLOR STAIN, NOT LESS THAN 2" (50MM) NOMINAL THICKNESS. SILL GASKET: CLOSED CELL POLYETHYLENE FOAM. GRAB BAR BLOCKING: 2" X 10" (38MM X 235MM). WOOD PRESERVATIVES: WOOD IN CONTACT WITH CONCRETE, MASONRY, AT ROOF UPSTANDS IN FLAT ROOFS, PLANTERS, HEAVY TIMBER CONSTRUCTION, FENCE POSTS AND CAVITY FURRING: PRESSURE TREATED MINIMUM 0.40 LB/FT2 TO CSA 080-M89, CLEAR, WATER BORNE, CHROMATE COPPER ARSENATE PRESERVERS BUREAU (CWPB) STAMPS. BOTTOM PLATE OF FRAME WALLS WITH SILL GASKETS DO NOT REQUIRE PRESSURE TREATING. USE HEM-FIR OR PINE INCISED LUMBER FOR TREATMENT. TREAT CUT SURFACES WITH TWO BRUSH OF COPPER NAPTHANATE PRESERVATIVE. EXECUTION: EXTERIOR WALL SILL PLATES: SET EXTERIOR WALL SILL PLATES ON FULL WIDTH STRIP OF FASCIA WINDOW TRIM, TRIM: INSTALL FASCIAS AND TRIMS IN LONGEST PRACTICAL LENGTHS, END JOINTS TO BE CUT IN 45 DEGREES AND LAPPED. FASTEN WITH HOT DIPPED GALVANIZED CASING NAILS AND COUNTERSINK. WOOD SIDING: INSTALL WALL CAVITY IF REQUIRED BY WALL DESIGN. USE LONGEST POSSIBLE LENGTHS TO MINIMIZE END JOINTS. INSTALL SIDING USING GALVANIZED SIDING OR CASING NAILS WITH RING OR SPRING SHANKS. DO NOT NAIL THROUGH OVERLAPPING PIECES. NAILS MUST BE LONG ENOUGH THAT THE NAIL PENETRATES THE FRAMING AT LEAST 1 1/4" (31.7MM). LAP BEVEL SIDING A MINIMUM OF 1" (25.4MM). SHIM BOTTOM EDGE OF SIDING TO PROVIDE A 1/8" (3MM) GAP BETWEEN IT AND THE SIDING BELOW. USE SOLID TRIMS AT INSIDE AND OUTSIDE CORNERS. BUTT SIDING INTO TRIMS. USE SOLID WOOD TRIMS AT THE INSIDE AND OUTSIDE CORNERS. BUTT SIDING INTO TRIMS.

SECTION 07200 INSULATION: PRODUCTS: EXTRUDED POLYSTYRENE: STANDARD CGSB51-GP-20M,TYPE 4. R: 5 PER INCH, RICHNESS: AS REQUIRED TO MEET P VALUE, LOCATION: FOUNDATION INSULATION. EXPANDED POLYSTYRENE: STANDARD: CGB51-GP-20M, TYPE 2, R: 4 PER INCH. THICKNESS: AS REQUIRED TO MEET R VALUE. LOCATION: CAVITY WALLS. BATT INSULATION: STANDARD: CSA A101-M83, TYPE 1. R VALUE: 19 . LOCATION WITHIN WOOD STUD WALLS, AND R 38 WITHIN CEILING. EXECUTION: EXTEND BOARDS A MINIMUM OF 24" (600MM) BELOW GRADE. INSTALL PERIMETER INSULATION USING MECHANICAL FASTENERS OR ADHESIVE. BUTT JOINT TIGHTLY, OFFSET HORIZONTAL AND VERTICAL JOINTS. USE LARGEST POSSIBLE SHEETS TO REDUCE NUMBER OF JOINTS. DO NOT USE CHIPPED OR CRACKED INSULATION BOARDS. PROTECT INSULATION WITH PRESSURE TREATED PLYWOOD AND PRE FINISHED METAL CAP FLASHINGS. INSULATION IN CAVITY WALLS: APPLY INSULATION IN CAVITY WALLS USING IMPALE TYPE CLIPS. FASTEN BOARDS WITH A MINIMUM OF (4) FASTENERS PER 24" X 48" (600MM X 1200MM) BOARD. BATT INSULATION: INSTALL FULL WIDTH AND LENGTH BETWEEN STUDS AND FRAMING MEMBERS TO FIT SNUGLY WITHOUT BUCKLING, CREASING OR CRUSHING. IN WALLS, INSTALL LOWER BATT FIRST; UPPER BUTT INSTALLED TO BUTT WITH THE FIRST AND ANY EXTRA LENGTH OF INSULATION TRIMMED AT TOP. FIT INSULATION TIGHT TO ELECTRICAL BOXES, PLUMBING AND HEATING PIPES AND DUCTS, AROUND EXTERIOR DOORS AND WINDOWS AND OTHER PROTRUSIONS. INSTALL INSULATION IN CONTINUOS CONTACT WITH INTERIOR SHEATING. ACCESS HATCHES: INSULATE ACCESS HATCHES TO THE SAME R VALUE AS THE ASSEMBLY IN WHICH THEY OCCUR.

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

8. FLOOR SLAB:

3. ROOF (RAFTERED): 9. FOUNDATION:

SECTION 07270 AIR BARRIER / SHEATHING MEMBRANE PRODUCT: TWO LAYERS OF 30 MINUTE ASPHALT SATURATED BUILDING PAPER CONFIRMING TO CAN-51.32M77 AND TO U.S. UUB-790a. EXECUTION: AIR BARRIER MEMBRANES MUST BE APPLIED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PRINTED INSTRUCTIONS AT ALL THE LOCATION IN THE EXTERIOR OF THE BUILDING ENVELOPE WHERE AIR IS FREE TO INFILTRATE THROUGH JOINTS IN COMPONENTS OF THE ASSEMBLIES AND AT JUNCTIONS WITH DISSIMILAR MATERIALS, CHANGES IN PLANE AND AT THE ROOF INSTALL SHEATHING MEMBRANE OVER EXTERIOR SHEATING. INSTALL ONE (1) LAYER OF ASPHALT SATURATED BUILDING PAPER HORIZONTALLY IN SUCCESSIVE STRIPS BEGINNING 2" (50MM) BELOW THE LOWEST POINT OF THE WALL FRAMING AND PROGRESSING UPWARDS WITH EACH SUCCEEDING SHEET. OVERLAP UPPER SHEET OVER LOWER SHEET A MINIMUM OF 4" (100MM) SO THAT LAPS ARE ARRANGED TO SHED WATER. END LAPS MUST HAVE A MINIMUM 12" (300MM) OVERLAP. STAGGER VERTICAL LAPS A MINIMUM OF 48" (1200MM). RETURN SHEET OVER FLASHINGS.

4. FASCIA:

10. DRAINAGE:

11. STAIRS: 5. EXTERIOR WALL:

4

12 12. BEARING WALL

SECTION 07300

6. INTERIOR WALL:

ASPHALT SHINGLE AND CEDAR SHINGLE/SHAKES IF APPLICABLE PRODUCTS: ASPHALT SHINGLES: ACCEPTABLE MATERIALS AS LISTED IN THE RCABC ROOFING PRACTICES MANUAL, TAB 2" ACCEPTABLE MATERIALS LIST", LATEST EDITION. SHINGLE MATERIALS MAY BE ORGANIC OR FIBERGLAS CORE PRODUCT. FASTENER: NAILS MUST BE LARGE HEAD, CORROSION RESISTANT, (ELECTRO-GALVANIZED, HOT DIPPED GALVANIZED, ALUMINUM), ROOFING NAILS. METAL FLASHING: BASE AND COUNTER FLASHING AND COPING METAL TO BE SHEET STEEL, MINIMUM 26 GAUGE, GALVANIZED TO ASTM A525,ZF275 COATING, PRE FINISHED WITH STELCOLOUR 5000 SERIES PAINT FINISH. STEP FINISHING MUST BE 26 GAUGE IN ACCORDANCE WITH RCABC REQUIREMENTS. ACCESSORIES: INSTALL ZINC. STRIPS TO ASPHALT SHINGLE AT ALL RIDGE LOCATIONS. INSTALL ZINC STRIP MUST BE 2" (50MM) EXPOSED TO THE WEATHER. EAVES PROTECTION: SELF ADHESIVE RUBBERIZED ASPHALT SHEET INSTALLED TO BUILDING CODE REQUIREMENTS. ACCEPTABLE MATERIALS AS LISTED IN RCABC ROOFING MANUAL TAB 2" ACCEPTABLE MATERIAL LIST", LATEST EDITION. UNDERLAY: 1 PLY OF No. 15 NON PERFORATED ASPHALT FELT TO CSA A123.3M1979. EXECUTION: ASPHALT SHINGLE ROOFING MUST BE INSTALLED ACCORD. TO RCABC,STR-LS FOR LOW SLOPE ROOFS. INSTALL UNDERLAY ON ALL ROOF DECKS WHERE ASPHALT SHINGLES OF ANY TYPE ARE TO BE INSTALLED. UNDERLAY TO BE MINIMUM 1 PLY OF No. 15 NON PERFORATED FELT, LAPPED MINIMUM 3"(75MM) OR THE SPECIFIC SHINGLE MANUFATURER'S. RECOMMENDED UNDERLAY. THIS UNDERLAY IS ADDITIONAL TO ANY MATERIAL USED FOR EAVES PROTECTION AND SHOULD BE LAPPED OVER THE LEADING (TOP) EDGE OF THE EAVES PROTECTION. PROVIDE SLOPE TO DRAIN IN ALL GUTTER APPLICATIONS. WATERPROOF LINING FOR "HIDDEN" OR "INBOARD" OR PLY FULLY TORCHED TO FIRST PLY. "BUILT-IN" TYPE GUTTERS MUST BE FULLY ADHERED 2 PLY MODIFIED BITUMEN SHEETS AND MUST THE BASE SHEET INSTALLED UP THE SLOPE OF THE ROOF A MINIMUM OF 18" (450MM) HIGHER THAN TOP OF OUTBOARD SIDE ELEVATION OF THE GUTTER. THE CAP SHEET IS TO PROVIDE UV PROTECTION AND MUST BE INSTALLED IN ALL AREAS EXPOSED TO U.V. USE SELF ADHERING BASE SHEET WHENEVER POSSIBLE WITH SECOND UV PROTECTIVE ENSURE DRAINS DISCHARGE INTO DOWN SPOTS THAT ARE KEPT ABOVE FREEZING.

NOTES FOR ROOF SPACE VENTILATION

13. CRAWL SPACE:

4

4

12

E.EL. 363.4 P.EL. 363.4

1. 2.

UNIFORMLY DISTRIBUTE VENTILATION TO FLAT AND VAULTED ROOFS TO 1/150 OF INSULATED CEILING AREA. PROVIDE 2x2 CROSS PURLINS TO FLAT, VAULTED CEILINGS AND DECKS OVER LIVING AREAS.

3. 4. 5. 6. 7.

PROVIDE MIN. 2-1/2" CLEARANCE BETWEEN ROOF SHEATHING AND INSULATION. PROVIDE MIN. 1" CLEARANCE BETWEEN TOP OF ROOF JOIST AND INSULATION. VENTILATE ATTIC SPACES TO 1/300 OF INSULATED CEILING AREA. ROOF VENTS MUST BE UNIFORMLY DISTRIBUTED WITH A MIN. OF 25% IN EAVES AND 25% IN ROOF TOP. PROVIDE ATTIC ACCESS OF 1'-8" X 2'-4" AND WEATHER-STRIP HATCH.

4

E.EL. 363.0 P.EL. 363.4

4

CLIENT:

E.EL. 363.4 P.EL. 363.4

SHEET TITLE:

MR.DOM PINEDA PROJECT: CIVIC ADDRESS:8066 -18TH AVE, BURNABY, BC

GARAGE DETAILS

E.EL. 362.4 P.EL. 363.1

E.EL. 361.9 P.EL. 362.6

12

E.EL. 362.4 P.EL. 363.1

12

12

E.EL. 361.9 P.EL. 362.6

E.EL. 363.0 P.EL. 363.4

DRAWN BY:

G.S.B

PROJECT NO.

CHECKED BY:

B.M.

239

DATE:

SEP. 2016

FILE NO.

SCALE:

1/4"=1'-0"

V14

SHEET NO:

C