6'-5" [1.96m]
PROJECT DATA:
CIVIC ADDRESS: 13721 - 56B AVENUE, SURREY ,BC
125' [38.10m]
ACCESSORY BLDG. 108 sq.ft
PROVIDED F.A.R.: 2972 + 2020 (excl. open to below) = 4992 S.F
5'-018" [1.53m] AVERAGE NATURAL GRADE ELEVATION: 91.29M
24'-73 8" [7.50m] 3068
MAIN FLOOR FINISHED GRADE ELEVATION: 91.94M SECOND FLOOR FINISHED GRADE ELEVATION: 95.35 M
66'-412" [20.23 m]
CEILING U/S ELEVATION: 98.15 M MEAN ROOF ELEVATION: 100.28 M PEAK ROOF ELEVATION: 102.42 M
CEILING U/S ELEVATION: 98.15 M
2'-712" [0.80m]
26'-23 4" [7.99m]
5' [1.52m]
MEAN ROOF ELEVATION: 100.28 M
2% SLOPE STORM WATER 25'-35 8" [7.71m]
INV. 91.14
22'-618" [6.86m]
SECOND FLOOR FINISHED GRADE ELEVATION: 95.35 M
70'-512" [21.48m]
5m]
25' [7.62m]
MAIN FLOOR FINISHED GRADE ELEVATION: 91.94M
25' [7.62m]
28'-518" [8.66m]
3.5% SLOPE
MAIN BUILDING GRADES:
23'-7" [7.19m]
MAX. ALLOWED HEIGHT: 30'-0" (9.00M) MAX. PROPOSED HEIGHT: 29'-6" (9.00M)
25'-5" [7 .7
E.EL.91.51 P.EL.91.51
4'-10" [1.48m]
E.EL.91.06 P.EL.91.31
20'-2" [6.14m]
HEIGHT:
AVERAGE NATURAL GRADE ELEVATION: 91.29M
]
MAIN BUILDING GRADES:
66'-414" [20.2 2m
[7.63m]
47'-87 8" [14.55m]
25'-0 58"
MAIN FLOOR: 2972S.F (incl. Garage ) GARAGE: 421 S.F UPPER FLOOR: 2222 S.F [INCL. OPEN TO BELOW] 405+139 = 544 S.F. PERMITTED O.T.B. : 200 S.F NET UPPER FLOOR. : 2020 S.F THE ABOVE AREAS NOT INCLUDING SUNDECKS TOTAL FLOOR AREA = 4992 S.F
25' [7.62m]
line of upper floor
PROVIDED TOTAL FLOOR AREA:
TOTAL FLOOR AREA= 2972 (M) +2020 (U)
E.EL.91.42 P.EL.91.52
E.EL.91.17 P.EL.91.37
10'-15 8" [3.09m]
LOT AREA: 9,978 SFT PERMITTED F.A.R. = 4992 S.F (INCL. GARAGE)
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
FLOOR AREA RATIO (F.A.R):
7'-018" [2.14m]
5'-1" [1.55m]
LOT AREA = 927 SQ.M. = 9,978 SFT
15' [4.57m]
ZONING: RH - 100 / RF
2' [0.61m]
14'-112" [4.31m
]
9'-11" [3.03m]
PID: 001-989-201
14'-158" [4.31m ]
NWD PLAN 19866
9'-7" [2.92m]
LOT 18, SECTION 9 TOWNSHIP 2
5' [1.52m]
PEAK ROOF ELEVATION: 102.42 M
COVERED OUTDOOR SPACE: ALLOWED 10% 4992 =499.2 S.F. - 160 PORCH = 339.2 S.F. PROVIDED =300 S.F.
SITE COVERAGE: ALLOWED SITE COVERAGE: = 3193 S.F PROVIDED SITE COVERAGE (BLDG. AND DECKS)
= 3080 S.F
19'-115 8" [6.09m]
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
29'-614" [9.00m]
CLIENT:
13'-93 8" [4.20m]
SHEET TITLE:
HARJINDERPAL SINGH NAGRA PROJECT: CIVIC ADDRESS:13721 -56B St, SURREY, BC LEGAL DESCRIPTION: LOT 18 SECTION 9 TOWNSHIP 2
38'-914" [11.82m]
site plan
DRAWN BY:
G.S.M.
PROJECT NO.
CHECKED BY:
B.M.
169
DATE:
SEP. 2016
FILE NO.
SCALE:
1/8"=1'-0"
V12
SHEET NO:
A
1/7
70'-7" 11'-0"
5'-1" [1.55m]
11'-10"
14'-3"
19'-7"
8'-10"
1'-10" 5'-11"
5'-1"
8'-0"
2'-0"
2'-6"
2'-8"
10'-6"
2'-0"
2'-512" [0.75m]
4'-10"
1'-5" 2'-0"
19'-7"
2'-1"
2'-712" [0.80m]
5'-1" 19'-4"
UP 3R@5 21"
3080
47'-10"
12'-612" [3.82m]
DECK 5'-0" wide
6'-8"
6080
16'-9"
5'-10"
3068
4'-0" 3'-0"
UP 3R @ 7"
16'-6" [5.03m]
3'-6"
5040RS 2680
FX
6'-1"
3'-10"
15
A A1
1068
1'-0" 1'-0"
80080
DN 3R@7"
3'-11" 3'-0"
2'-11"
2680
4660RS
4'-5"
3090 1068
2680
4'-6"
3060RS
1'-0"
8090
6080
4'-8" 3'-6"
3'-11"
2'-9"
9'-6"
8090
7086RS
18'-93 8" [5.73m]
13'-10"
5'-0"
24'-5"
3'-7"
2'-11"
2680
6'-4"
2680
24'-618" [7.47m]
4660RS
1'-10"
4040RS
EFFECTIVE RSI CALCULATION FOR GARAGE SLAB 4" - R 28 RIGID INSULATION RSI 4.93 UNDER SLAB POLYETHYLENE - 0 1 RSI 0.08 2" GYPSUM WALL BOARD TOTAL EFFECTIVE INSULATION VALUE RSI 5.01
3'-3"
2'-10"
4'-11"
19'-2"
4'-3"
2'-8"
12080
6'-0"
21'-0"
13'-11"
60
15'-3"
19'-5"
2'-6"
21080
5'-6"
2'-1"
1'-0"
1'-10"
3080
6'-7"
8'-6"
Decorative Pillar (Non-Structural)
7'-0"
3080
9'-0"
9'-5"
7068
SOLID CORE DOOR C/W WEATHER STRIPPING & SELF CLOSER
4'-2"
8080
5'-0"
3'-0"
12'-4"
2'-11"
3'-6"
2680
Range
2680
2'-5"
80 26
3R@5 21" 2T@10"
5'-1"
UP 2R@6 21"
SMOKE ALARM & CARBON MONOXIDE (CO) ALARM
5'-0"
2680
43'-6"
A A1
S CO
2680
2'-5"
5'-9"
8'-7"
1'-0"
Refrigerator
10'-2" 2680
2680
4'-6"
2630RS
2'-5" 1'-11" 9"
3060RS
2640RS
2'-0"
3060RS
OVEN/MW
10'-8"
2640RS
3040RS
5'-1" [1.55m]
2640RS
line of floor above
21068
3040RS
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
9'-11"
10'-17 8" [3.09m]
2'-7"
2640RS
2' [0.61m]
2630RS
5'-0"
1'-0"
5060RS
5060RS
main floor plan scale: 14" = 1'-0"
10'-1"
7'-6"
10'-1" 20'-1"
5'-2"
1'-6"1'-11"
3'-10"
12'-8"
3'-9"
12'-10"
34'-3"
1'-11" 1'-6"
3'-0"
2'-9"
7'-10"
4'-3"
7'-3"
5'-8"
17'-9" 25'-6"
10'-10" 70'-7"
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
SHEET TITLE:
HARJINDERPAL SINGH NAGRA PROJECT: CIVIC ADDRESS:13721 -56B St, SURREY, BC LEGAL DESCRIPTION: LOT 18 SECTION 9 TOWNSHIP 2
MAIN FLOOR PLAN
DRAWN BY:
G.S.M.
PROJECT NO.
CHECKED BY:
B.M.
169
DATE:
SEP. 2016
FILE NO.
SCALE:
1/4"=1'-0"
V12
SHEET NO:
A
2/7
61'-6"
2840RS
9'-10"
2'-1"
2840RS
2680
2840RS
1'-9" 1'-9"
2840RS
13
56
3'-11"
RS
13'-8"
4040 SKY LIGHT
43'-9" 1'-10"
2056RS 3680
A A1
2680
6'-11"
2680
2040RS
3080
6'-11"
4'-0"
2650RS
4030RS
6050RS
1'-2"
9'-4"
7'-9"
2626
17'-5"
2650RS
4'-4"
1'-5"
3040RS
1'-11" 5'-9"
2680
2680
1'-3"
4'-0"
Shower 3'6" x 5'0"
A A1
7'-9"
1'-3"1'-5" 1'-9"
2640RS
3680
3040RS
2640RS 2840RS
2680 2050RS
3680
2840RS
8'-10"
10'-3" 4'-5"
3040RS
16'-1" 9'-9"
39'-9"
BUILDING - INTERIOR DESIGNERS
2840RS
3'-8"
2680
UDC DESIGN CENTER LTD
10'-3"
2840RS
3'-8"
12'-8"
1'-9" 1'-9"
2'-1"
8'-11"
2680
1'-8" 2'-1"
13'-8"
2680
5'-7"
4'-0"
10'-11"
5'-5"
2680
2'-2"
5'-5"
12'-9"
2840RS
24'-4"
8050RS
4'-8"
4'-0"
2'-5" 1'-8"
17'-0"
5'-8"
12'-9"
5'-0"
3'-3" 8'-2"
22'-9"
8'-11"
8'-11" 17'-10"
61'-6"
upper floor plan
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
SHEET TITLE:
HARJINDERPAL SINGH NAGRA PROJECT: CIVIC ADDRESS:13721 -56B St, SURREY, BC LEGAL DESCRIPTION: LOT 18 SECTION 9 TOWNSHIP 2
UPPER FLOOR PLAN
DRAWN BY:
G.S.M.
PROJECT NO.
CHECKED BY:
B.M.
169
DATE:
SEP. 2016
FILE NO.
SCALE:
1/4"=1'-0"
V12
SHEET NO:
A
3/7
7'-018" [2.14m]
ROOF RIDGE LVL. 102.42 12 8
MEAN ROOF LVL. 100.28 7' [2.13m]
1
U/S CEILING LVL. 98.15
2
5
9'-214" [2.80m]
12
29'-6" [9.00m]
4
8 8
11'-214" [3.41m]
8
6 7 8
MAIN FL. LVL. 91.94 AVE. GRADE. LVL. 91.29
E.EL.91.51 P.EL.91.51 E.EL.91.06 P.EL.91.31
ROOF RIDGE LVL. 102.42 7'-018" [2.14m]
front elevation scale: 14" = 1'-0"
12 8
MEAN ROOF LVL. 100.28 12
7' [2.13m]
LIST OF MATERIALS
ASPHALT SHINGLE 40 YRS - IKO CAMBRIDGE, DUAL BLACK
2.
BUILT-IN GUTTER - METAL SOFFIT WITH 2" CONTINUOUS SCREENED VENT
3.
1 x 8 ON 2" X 10" FASCIA BOARD
4.
1" X 4" WOODEN TRIM
5.
STUCCO
6.
ALUMINUM FRAMED WINDOW AND PATIO DOOR
7.
WOODEN EXTERIOR DOOR
8.
STONE
9.
CEDAR SHAKE SIDING
U/S CEILING LVL. 98.15
9'-214" [2.80m]
1.
2650RS 12.5
right elevation
TOTAL AREA: 989 SQ. FT. ( 91.88 SQ.M.) scale: 14" = 1'-0" DISTANCE TO PROPERTY LINE: 25'-0" (7.62 M) ≈ 8.0M MAX. ALLOWABLE UNPROTECTED AREA @ 100% = 989 SQ. FT. ( 91.88 SQ. M.) PROPOSED UNPROTECTED AREA: 218.38 SQ. FT (20.28 SQ. M.)
2850RS
2650RS
2056RS 7
12.5
5-1356FX
2056RS 7
2850RS
10.5
10.5
5
29'-6" [9.00m]
SECOND FLOOR LVL. 95.35
RIGHT ELEVATION
16
5x6.875
12
5
8
8 8
11'-214" [3.41m]
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
SECOND FLOOR LVL. 95.35
3
8
12
5040RS 4670RS 27
8
4670RS 27
5-1380FX
20
5X10
MAIN FL. LVL. 91.94 AVE. GRADE. LVL. 91.29
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
E.EL.91.42 P.EL.91.52
E.EL.91.51 P.EL.91.51
SHEET TITLE:
HARJINDERPAL SINGH NAGRA PROJECT: CIVIC ADDRESS:13721 -56B St, SURREY, BC LEGAL DESCRIPTION: LOT 18 SECTION 9 TOWNSHIP 2
FRONT & RIGHT ELEVATION
DRAWN BY:
G.S.M.
PROJECT NO.
CHECKED BY:
B.M.
169
DATE:
SEP. 2016
FILE NO.
SCALE:
1/4"=1'-0"
V12
SHEET NO:
A
4/7
7'-018" [2.14m]
ROOF RIDGE LVL. 102.42 12 8
7' [2.13m]
MEAN ROOF LVL. 100.28
9'-214" [2.80m]
5
12
29'-6" [9.00m]
8
11'-214" [3.41m]
SECOND FLOOR LVL. 95.35
MAIN FL. LVL. 91.94
5
E.EL.91.42 P.EL.91.52
AVE. GRADE. LVL. 91.29
E.EL.91.17 P.EL.91.37
ROOF RIDGE LVL. 102.42 7'-018" [2.14m]
rear elevation
12 8
7' [2.13m]
MEAN ROOF LVL. 100.28
U/S CEILING LVL. 98.15
9'-214" [2.80m]
12
LEFT ELEVATION
TOTAL AREA: .741.74 SQ. FT. ( 69 SQ.M.) DISTANCE TO PROPERTY LINE: 25'-0" (7.62 M) ≈ 8.0M MAX. ALLOWABLE UNPROTECTED AREA @ 100% = 741.74 SQ. FT. ( 69 SQ.M.) PROPOSED UNPROTECTED AREA: 75.5 SQ. FT (7.01 SQ. M.)
3040RS 12
29'-6" [9.00m]
SECOND FLOOR LVL. 95.35
12
11'-214" [3.41m]
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
U/S CEILING LVL. 98.15
5
3040RS 12
2040RS 8
12 12
2630RS 7.5
10
10
5
4040RS 2640RS
2640RS 16
left elevation MAIN FL. LVL. 91.94 AVE. GRADE. LVL. 91.29
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
E.EL.91.17 P.EL.91.37
CLIENT:
E.EL.91.06 P.EL.91.31
SHEET TITLE:
HARJINDERPAL SINGH NAGRA PROJECT: CIVIC ADDRESS:13721 -56B St, SURREY, BC LEGAL DESCRIPTION: LOT 18 SECTION 9 TOWNSHIP 2
REAR AND LEFT ELEVATION
DRAWN BY:
G.S.M.
PROJECT NO.
CHECKED BY:
B.M.
169
DATE:
SEP. 2016
FILE NO.
SCALE:
V12
SHEET NO:
A
5/7
DUROID ROOF BUILDING PAPER ON 12" PLYWOOD ENG.TRUSSES @24" O/C R-40 BATT INSULATION 6 MIL POLY V.B. (LAPPED JOINTS,SEAL ELECT. OUTLETS) (WARM SIDE) 5 8" GYPSUM BOARD BUFFLES 2" CLEAR FROM TOP
7'-018" [2.14m]
12
MEAN ROOF LVL. 100.28 7' [2.13m]
8
ATTIC ATTIC VENTILATION AS PER BUILDINGCODE A/300 OF INSULATED CEILING AREA MIN. 25% OF VENTING @TOP & 25% @ BOTTOM
U/S CEILING LVL. 98.15
2
ROOF:
5
- ROOF FINISH: 210 # ASPHALT SHINGLES ROOF - STARTER STRIP - 716" OSB SHEATHING c/w. H. CLIPS - PREFAB. ENG. TRUSSES @ 24" O.C. - R-50 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.
2
EAVES:
- FINISH FLOOR: TO OWNERS SPEC'S - P.T. 2x10 @16 o.c. JOISTS AS PER MANUFACTURERS SPECS - 11/2"th. CONCRETE TOPPING - R-40 SPRAT FOAM INSULATION -5
6
TYPE "X" GYPSUM BOARD (FIN. AS PER OWNER)
SECOND FLOOR LVL. 95.35
BASEMENT FLOOR:
INTERIOR PARTITIONS ( 1 hr FRR): - 1/2" GYPSUM BOARD (BOTH SIDES) - 2 x 4 STUDS @ 16" O.C. - INSUALTED CAVITY
4
8"
- FINISH FLOOR: TO OWNERS SPEC'S - 0'-6" CONC. SLAB - 10 GA 6 x 6 WIRE MESH - 6 MIL. POLY. V.B. - R-10 RIGID INSULATION - MIN. 12" COMPACTED GRANULAR FILL
- BUILT-IN GUTTER - 2 x 12 FASCIA BOARD - METAL SOFFIT WITH 2" CONTINUOUS SCREENED VENT
3
MAIN FLOOR (1 hr FRR):
EXTERIOR WALLS (2 hr FRR): - STUCCO ON WIREMESH - METAL LATH - 19MM (3/4") AIR SPACE / @ 16" O.C. - 15# BREATHER TYPE BUILDING PAPER - 15 32" SHEATHING - 2 x 6 STUDS @ 16" O.C. - R-20 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
7
12 12
112" CONC. TOPPING
29'-6" [9.00m]
1
9'-214" [2.80m]
SECTIONAL DETAILS AND SPECIFICATIONS:
ND
FOUNDATION WALLS: - 2 x 6 SILL PLATE - 8" CONC. FOUNDATION WALL - 2 COATS OF ASHPALT EMULSION TO EXTERIOR FACE - 2 - 15M T & B, 10M @16" O.C E/W.1.F UP TO GRADE
INTERNAL INSULATED WALL
5
IL RA
4
HA
3'-
3
5 MAIN FL. LVL. 91.94
H
IG
H 0"
11'-214" [3.41m]
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
ROOF RIDGE LVL. 102.42
112" CONC. TOPPING
5
8" ANCHOR BOLTS @ 36" O.C.(TYOP)
2-15M CONTINUOUS
7
AVE. GRADE. LVL. 91.29
- 2" AIR SPACE - 2 x 4 SPF # 2 STUDS @ 24" O.C. (U.N.O.) - R-14 BATT. INSULATION - 6 MIL. POLY. V.B. - C/W TUCK TAPE JOINTS - 1/2" DRYWALL
CLIENT:
SHEET TITLE:
HARJINDERPAL SINGH NAGRA PROJECT: CIVIC ADDRESS:13721 -56B St, SURREY, BC LEGAL DESCRIPTION: LOT 18 SECTION 9 TOWNSHIP 2
SECTION
DRAWN BY:
G.S.M.
PROJECT NO.
CHECKED BY:
B.M.
169
DATE:
SEP. 2016
FILE NO.
SCALE:
1/4"=1'-0"
V12
SHEET NO:
A
6/7
ROOF PEAK EL. = 95.22
12 6
13'-2" [4.01m]
10'-8"
5'-4"
9' [2.74m]
STUCCO
5'-4"
STUCCO
SHED SLAB EL. = 91.20
SHED SLAB EL. = 91.20
WEST ELEVATION
12
NET FLOOR AREA = 108 SQ. FT.
9' [2.74m]
UNDER SIDE OF TRUSS EL. = 93.94
STUCCO
6
CENTER OF TRUSS EL. = 94.58 UNDER SIDE OF TRUSS EL. = 93.94
13'-2" [4.01m]
CENTER OF TRUSS EL. = 94.58
2'-1" [0.64m]
12 6
ROOF PEAK EL. = 95.22
STUCCO
SHED SLAB EL. = 91.20
EAST ELEVATION
13'-2" [4.01m]
ROOF PEAK EL. = 95.22
2'-1" [0.64m]
SHED
9' [2.74m]
10'-0"
2'-1" [0.64m]
2'-1" [0.64m]
NORTH ELEVATION
SHED SLAB EL. = 91.20
SOUTH ELEVATION
2'-1" [0.64m]
3
ENGINEERED TRUSSES @24 O.C. BY OTHERS
CENTER OF TRUSS EL. = 94.58
5
UNDER SIDE OF TRUSS EL. = 93.94
4 SHED 18'8"X9'8"
2
CONSTRUCTION SPECIFICATIONS
13'-2" [4.01m]
6
2'-1" [0.64m]
ROOF PEAK EL. = 95.22
12
9' [2.74m]
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
10'-8"
5016RS
SHED
UNDER SIDE OF TRUSS EL. = 93.94
13'-2" [4.01m]
UNDER SIDE OF TRUSS EL. = 93.94
+203.41
CENTER OF TRUSS EL. = 94.58
2'-1" [0.64m]
6 CENTER OF TRUSS EL. = 94.58
2868
18'8"X9'8"
ROOF PEAK EL. = 95.22
12
9' [2.74m]
WEATHERSTRIP SOLID CORE,
2'-1" [0.64m]
2'-1" [0.64m]
2'-0"
2'-1" [0.64m]
10'-0" 8'-0"
1 SHED SLAB EL. = 91.20
6
1. MAIN FLOOR SLAB -4" CONC. SLAB -6x6 WELDED WIRE MESH -6 MIL. POLY VAPOR BARRIER -6" MIN. COMPACTED SAND (TYPICAL)
4. EAVES
2. EXTERIOR WALLS STUCCO -#10 BUILDING PAPER -1/2" EXT. GRADE PLYWOOD SHEATHING -2x6 STUDS @ 16" o/c.(U.N.O.) -R20 F.G. BATT INSULATION -6 MIL POLY VAPOR BARRIER U.V.R. -1/2" GYPSUM BOARD
5. ATTIC VENTILATION
-5" ALUM. GUTTER -2x10 FASCIA BOARD -2x4 BACK NAILER -METAL SOFFIT WITH 2" CONT. SCREENED VENTILANT
-2" BAFFLE CLEARANCE WITH INSULATION STOPS 6. FOUNDATION -SEE FOUNDATION DETAIL
3. TRUSS ROOF -ASPHALT SHINGLE -BUILDING PAPER -1x4 STRAPPING -ENGINEERED TRUSSES @ 24" o/c(SEE TRUSS LAYOUT) -R-40 F.G. BATT INSULATION -6 MIL POLY VAPOR BARRIER -5/8" GYPSUM BOARD
SECTION B
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
SHEET TITLE:
HARJINDERPAL SINGH NAGRA PROJECT: CIVIC ADDRESS:13721 -56B St, SURREY, BC LEGAL DESCRIPTION: LOT 18 SECTION 9 TOWNSHIP 2
SHED DETAILS
DRAWN BY:
G.S.M.
PROJECT NO.
CHECKED BY:
B.M.
169
DATE:
SEP. 2016
FILE NO.
SCALE:
1 " 4
= 1'-0"
V12
SHEET NO:
A
7/7
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
∙
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
SHEET TITLE:
HARJINDERPAL SINGH NAGRA PROJECT: CIVIC ADDRESS:13721 -56B St, SURREY, BC LEGAL DESCRIPTION: LOT 18 SECTION 9 TOWNSHIP 2
ENERGY DETAIL
DRAWN BY:
G.S.M.
PROJECT NO.
CHECKED BY:
B.M.
169
DATE:
SEP. 2016
FILE NO.
SCALE:
N.T.S.
V12
SHEET NO:
A
GRID
GRID
HEADER
EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
SEAL POLYETHYLENE (A.B. & V.B.) TO HOUSEWRAP (A.B.) 1/2"CONTROL JOINT FLOOR FINISH ON C/W CAULK AND ROD CONCRETE TOPPING
MIN. 3/8" GAP BETWEEN WINDOW & 1X2 STRAPPING
EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
4" ADHERED FLASHING MEMBRANE
INTERIOR
100 mm (4")
FLOOR FINISH ON CONCRETE TOPPING
SHEATHING PAPER BEHIND FLASHING AND INTO WINDOW OPENING INSECT SCREEN
MIN. 2% SLOPE TO DRAIN SEALANT JOINT AT VENT DUCT TO HOUSEWRAP (A.B.)
2"CONTINUOUS FLANGE AT PERIMETER OF HOOD
ROD AND SEALANT STUD @ 16" O.C
2"
2
SEALANT OR GASKET (A.B.) BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED
1 MIN 2"
BLDG. PAPER
4.06
23.03
EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY
3.99
22.61
0.68
4.11
23.29
ADHERED MEMBRANE FLASHING TO LAP 100mm (4") OVER SHEATHING PAPER BELOW
ROOF ASSEMBLY COMPONENTS (W/ ASPHALT SHINGLES) 1 ROOFING SHINGLES 2 POLYTHENE V.B 5 ″ (15.88 MM) OSB SHEATHING 3 8 4 2 x 10 JOISTS W/ R50 BATT @ 24″ O.C. 5 POLYETHYLENE 6 1/2″ (12.7 MM) GYPSUM BOARD 7 INTERIOR AIR FILM
RSI 0.077 0.00 0.136 8.8 0.00 0.08 0.12
R 0.44 0.00 0.77 50.0 0.00 0.45 0.68
SEALANT OR GASKET JOINT AT POLYETHYLENE (A.B. & V.B.) TO PLATE (A.B.)
2X10 FLOOR JOISTS
SEAL POLYETHYLENE (V.B.) TO SHEATHING PAPER (A.B.)
EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY
9.21
50.34
FLOOR ASSEMBLY OVER UNHEATED SPACE 1 EXTERIOR AIR FILM 2 FLOOR FINISHES (3 4" HARDWOOD) 3 POLYETHYLENE 4 512" CONC. SLAB 5 R-28 INSULATION 9 NATURAL GRADE
RSI 0.03 0.12 0.00 0.15 4.99 0.00
R 0.17 0.68 0.00 0.83 28.00 0.00
EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY
5.29
29.68
TRIPLE GLAZED WINDOWS & DOORS LOW E, DOUBLE GLAZED (6mm GAP), TEMPERED GLASS εn = 0.1, AIR FILLED WITH VINYL OR FIBRE GLASS FRAME
USI
U
1.4
0.246
1" 2
SEPERATION AIR SPACE
EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY
1 MIN.
PREFINISHED METAL FLASHING C/W END DAMS TO EXTEND 1" PAST END OF WINDOW FRAME
VENTED ALUMINUM SOFFIT PANELS EFFECTIVE RSI - 4.06 SEAL SHEATHING PAPER (A.B.) TO WINDOW FRAME REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
VALUES ADOPTED FROM CANADIAN WOOD COUNCIL
VALUES ADOPTED FROM CANADIAN WOOD COUNCIL
1.5" SILL PLATE
BUILDING - INTERIOR DESIGNERS
EXTERIOR STUCCO CLADDING
- HEAVY- DUTY POLYVINYL CHLORIDE (PVC )
INTERIOR
AIR SPACE W/ 1x2 TREATED WOOD STRAPPING SCREWED THROUGH INSULATION
THERMOPLASTIC WATER PROOFING MEMBRANES ARE OVERLAPPED AND HEAT FUSED ( APPLICATION CODE :CGSB -37-GP-55M)
SEALANT OR GASKET POLYETHYLENE TO PLATE (A.B.)
FLASHING & COUNTER FLASHING
SEALANT OR GASKET (A.B.)
ASPHALT IMPREGNATED PAPER
INSECT SCREEN - NO DAMPERS
EFFECTIVE RSI VALUE = 6.06 ROOFING SHINGLES (M.B.) WATERPROOF ROOF MEMBRANE (M.B.) FOR EAVE PROTECTION 5/8" OSB ROOF SHEATHING W/ H CLIPS WOOD ROOF FRAMING R-50 BATT INSULATION POLYETHYLENE (A.B. & V.B.) GYPSUM BOARD
GRID
1/2″ (12.7 MM) PLYWOOD SHEATHING
2 X 2 BLOCKING AT BOTH ENDS OF VENT 11/2" CONT. VENT
POLYETHYLENE VAPOR BARRIER
ADHERE SUBFLOOR TO HEADER (A.B.) FLOOR FINISH ON CONCRETE TOPPING
EFFECTIVE USI VALUE - 1.4 OPERABLE VINYL OR FIBERGLASS FRAME LOW ENERGY, DBL. GLAZED TEMP. GLASS W/ SLOPED SILL WEATHER STRIPPING
EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 (RSI-1.06)
1/2″ (12.7 MM) GYPSUM BOARD
MIN. 2% SLOPE TO DRAIN
2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. SLOPED SUB-SILL FRAMING
SEALANT OR GASKET (A.B.) REFER TO W-1 FOR EXTERNAL WALL ASSEMBLY DETAIL
INSULATION GUARD
POLYETHYLENE (V.B. AND A.B.) SEALANT OR GASKET (A.B.)
EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
GASKET (A.B.)
BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED
LAP POLYETHYLENE AND SEAL TO ADHERED MEMBRANE (A.B. AND V.B.)
W-1
SEALANT AND BACKER ROD JOINT AT WINDOW FRAME TO MEMBRANE (A.B. AND M.B.) SEALANT FILLET JOINT PREFINISHED METAL DRIP FLASHING
SEALANT BETWEEN POLYETHYLENE AND HOUSEWRAP (A.B.) FLOOR FINISH ON CONCRETE TOPPING
INTERMITTENT 1/8" P.T. SHIM BEHIND WINDOW FLANGE TO CREATE DRAINAGE PATH (ALTERNATELY DRILL HOLES OR SLOTS THROUGH WINDOW FLANGES TO TO ALLOW FOR DRAINAGE)
HOUSEWRAP AT HEADER (A.B.)
BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED GYPSUM BOARD
BATT INSULATION POLYETHYLENE (V.B.) STAPLED IN PLACE
25mm (1")
ADHERED MEMBRANE FLASHING (M.B.) SILL GASKET (A.B.)
CEMENT OR ACRYLIC STUCCO PARGING
EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
8" CONC. FOUNDATION WALL
FINISHED GRADE
4" EXTRUDED POLYSTYRENE R-5/in. 1" 2
REFER TO W-2/A-501 FOR FND WALL ASSEMBLY DETAIL
DRYWALL FINISH
912"
INSECT SCREEN
SEE 'FLASHING-BEST PRACTICE GUIDE' FOR ADDITIONAL ROOF FLASHING DETAILS
DAMP PROOFING / VAP. BARRIER
1/2"
2" MIN.
FILTER CLOTH
VENTED ALUMINUM SOFFIT PANELS
FLOOR OVER UNHEATED SPACE EFFECTIVE RSI 2.06
512"
CEMENT OR ACRYLIC STUCCO PARGING
8" MINIMUM
SHEATHING PAPER TO LAP OVER ADHERED MEMBRANE FLASHING
EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
SEAL HOUSEWRAP (A.B.) TO FRAMING
CONTINUE EAVE PROTECTION 12" BEYOND INSIDE FACE OF WALL
ADHERED MEMBRANE FLASHING TO EXTEND 4" AND LAP OVER SHEATHING PAPER
INTERIOR
COMPLETE W/ 4" EXTRUDED POLYSTYRENE FOAM BOARD INSUL. R-5/in.
WOOD FRAMING (STUDS OR STRAPPING)
W-2 UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
SHEET TITLE:
HARJINDERPAL SINGH NAGRA PROJECT: CIVIC ADDRESS:13721 -56B St, SURREY, BC LEGAL DESCRIPTION: LOT 18 SECTION 9 TOWNSHIP 2
GENERAL DETAIL
RSI R 0.03 0.17 0.035 0.20 1.06 6.00 0.00 0.00 0.11 0.62 2.55 14.49 0.00 0.00 0.08 0.45 0.00 0.00 0.12 0.68 .12
2a
2 SEALANT OR GASKET (A.B.)
EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY
12mm (1/2")
SEAL POLYETHYLENE (A.B. & V.B.) TO HOUSEWRAP (A.B.)
1X2 STRAPPING
UDC DESIGN CENTER LTD
4" FLANGE
25.4mm (1")
R 0.17 0.62 6.00 0.00 0.62 14.49 0.00 0.45 0.00 0.68
WALL ASSEMBLY COMPONENTS (W/ STUCCO CLADDING) 1 EXTERIOR AIR FILM 3 " STUCCO FIN. 2 4 3 EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 4 ASPHALT IMPREGNATED PAPER2 5 1/2″ (12.7 MM) PLYWOOD SHEATHING 6 2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. 7 POLYETHYLENE 8 1/2″ (12.7 MM) GYPSUM BOARD 9 FINISH: 1 COAT LATEX PRIMER AND LATEX PAINT 10 INTERIOR AIR FILM
SHEATHING PAPER TO LAP METAL FLASHING
ROD AND SEALANT 1
RSI 0.03 0.11 1.06 0.00 0.11 2.55 0.00 0.08 0.00 0.12
VALUES ADOPTED FROM CANADIAN WOOD COUNCIL
4" FLANGE 6
WALL ASSEMBLY COMPONENTS (W/ NINYL CLADDING) 1 EXTERIOR AIR FILM 2 VINYL SIDING (NO AIR SPACE) 3 EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 4 ASPHALT IMPREGNATED PAPER 5 1/2″ (12.7 MM) PLYWOOD SHEATHING 6 2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. 7 POLYETHYLENE 8 1/2″ (12.7 MM) GYPSUM BOARD 9 FINISH: 1 COAT LATEX PRIMER AND LATEX PAINT 10 INTERIOR AIR FILM
EXTERIOR
4"
EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
RSI / R VALUE CALCULATIONS FOR ASSEMBLIES
EFFECTIVE USI VALUE - 1.4 OPERABLE VINYL OR FIBERGLASS FRAME LOW ENERGY, DBL. GLAZED TEMP. GLASS W/ SLOPED SILL WEATHER STRIPPING
GRID
DRAWN BY:
G.S.M.
PROJECT NO.
CHECKED BY:
B.M.
169
DATE:
SEP. 2016
FILE NO.
SCALE:
N.T.S.
V12
SHEET NO:
B