Harjinderpal singh nagra 13721 56b st

Page 1

6'-5" [1.96m]

PROJECT DATA:

CIVIC ADDRESS: 13721 - 56B AVENUE, SURREY ,BC

125' [38.10m]

ACCESSORY BLDG. 108 sq.ft

PROVIDED F.A.R.: 2972 + 2020 (excl. open to below) = 4992 S.F

5'-018" [1.53m] AVERAGE NATURAL GRADE ELEVATION: 91.29M

24'-73 8" [7.50m] 3068

MAIN FLOOR FINISHED GRADE ELEVATION: 91.94M SECOND FLOOR FINISHED GRADE ELEVATION: 95.35 M

66'-412" [20.23 m]

CEILING U/S ELEVATION: 98.15 M MEAN ROOF ELEVATION: 100.28 M PEAK ROOF ELEVATION: 102.42 M

CEILING U/S ELEVATION: 98.15 M

2'-712" [0.80m]

26'-23 4" [7.99m]

5' [1.52m]

MEAN ROOF ELEVATION: 100.28 M

2% SLOPE STORM WATER 25'-35 8" [7.71m]

INV. 91.14

22'-618" [6.86m]

SECOND FLOOR FINISHED GRADE ELEVATION: 95.35 M

70'-512" [21.48m]

5m]

25' [7.62m]

MAIN FLOOR FINISHED GRADE ELEVATION: 91.94M

25' [7.62m]

28'-518" [8.66m]

3.5% SLOPE

MAIN BUILDING GRADES:

23'-7" [7.19m]

MAX. ALLOWED HEIGHT: 30'-0" (9.00M) MAX. PROPOSED HEIGHT: 29'-6" (9.00M)

25'-5" [7 .7

E.EL.91.51 P.EL.91.51

4'-10" [1.48m]

E.EL.91.06 P.EL.91.31

20'-2" [6.14m]

HEIGHT:

AVERAGE NATURAL GRADE ELEVATION: 91.29M

]

MAIN BUILDING GRADES:

66'-414" [20.2 2m

[7.63m]

47'-87 8" [14.55m]

25'-0 58"

MAIN FLOOR: 2972S.F (incl. Garage ) GARAGE: 421 S.F UPPER FLOOR: 2222 S.F [INCL. OPEN TO BELOW] 405+139 = 544 S.F. PERMITTED O.T.B. : 200 S.F NET UPPER FLOOR. : 2020 S.F THE ABOVE AREAS NOT INCLUDING SUNDECKS TOTAL FLOOR AREA = 4992 S.F

25' [7.62m]

line of upper floor

PROVIDED TOTAL FLOOR AREA:

TOTAL FLOOR AREA= 2972 (M) +2020 (U)

E.EL.91.42 P.EL.91.52

E.EL.91.17 P.EL.91.37

10'-15 8" [3.09m]

LOT AREA: 9,978 SFT PERMITTED F.A.R. = 4992 S.F (INCL. GARAGE)

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

FLOOR AREA RATIO (F.A.R):

7'-018" [2.14m]

5'-1" [1.55m]

LOT AREA = 927 SQ.M. = 9,978 SFT

15' [4.57m]

ZONING: RH - 100 / RF

2' [0.61m]

14'-112" [4.31m

]

9'-11" [3.03m]

PID: 001-989-201

14'-158" [4.31m ]

NWD PLAN 19866

9'-7" [2.92m]

LOT 18, SECTION 9 TOWNSHIP 2

5' [1.52m]

PEAK ROOF ELEVATION: 102.42 M

COVERED OUTDOOR SPACE: ALLOWED 10% 4992 =499.2 S.F. - 160 PORCH = 339.2 S.F. PROVIDED =300 S.F.

SITE COVERAGE: ALLOWED SITE COVERAGE: = 3193 S.F PROVIDED SITE COVERAGE (BLDG. AND DECKS)

= 3080 S.F

19'-115 8" [6.09m]

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

29'-614" [9.00m]

CLIENT:

13'-93 8" [4.20m]

SHEET TITLE:

HARJINDERPAL SINGH NAGRA PROJECT: CIVIC ADDRESS:13721 -56B St, SURREY, BC LEGAL DESCRIPTION: LOT 18 SECTION 9 TOWNSHIP 2

38'-914" [11.82m]

site plan

DRAWN BY:

G.S.M.

PROJECT NO.

CHECKED BY:

B.M.

169

DATE:

SEP. 2016

FILE NO.

SCALE:

1/8"=1'-0"

V12

SHEET NO:

A

1/7


70'-7" 11'-0"

5'-1" [1.55m]

11'-10"

14'-3"

19'-7"

8'-10"

1'-10" 5'-11"

5'-1"

8'-0"

2'-0"

2'-6"

2'-8"

10'-6"

2'-0"

2'-512" [0.75m]

4'-10"

1'-5" 2'-0"

19'-7"

2'-1"

2'-712" [0.80m]

5'-1" 19'-4"

UP 3R@5 21"

3080

47'-10"

12'-612" [3.82m]

DECK 5'-0" wide

6'-8"

6080

16'-9"

5'-10"

3068

4'-0" 3'-0"

UP 3R @ 7"

16'-6" [5.03m]

3'-6"

5040RS 2680

FX

6'-1"

3'-10"

15

A A1

1068

1'-0" 1'-0"

80080

DN 3R@7"

3'-11" 3'-0"

2'-11"

2680

4660RS

4'-5"

3090 1068

2680

4'-6"

3060RS

1'-0"

8090

6080

4'-8" 3'-6"

3'-11"

2'-9"

9'-6"

8090

7086RS

18'-93 8" [5.73m]

13'-10"

5'-0"

24'-5"

3'-7"

2'-11"

2680

6'-4"

2680

24'-618" [7.47m]

4660RS

1'-10"

4040RS

EFFECTIVE RSI CALCULATION FOR GARAGE SLAB 4" - R 28 RIGID INSULATION RSI 4.93 UNDER SLAB POLYETHYLENE - 0 1 RSI 0.08 2" GYPSUM WALL BOARD TOTAL EFFECTIVE INSULATION VALUE RSI 5.01

3'-3"

2'-10"

4'-11"

19'-2"

4'-3"

2'-8"

12080

6'-0"

21'-0"

13'-11"

60

15'-3"

19'-5"

2'-6"

21080

5'-6"

2'-1"

1'-0"

1'-10"

3080

6'-7"

8'-6"

Decorative Pillar (Non-Structural)

7'-0"

3080

9'-0"

9'-5"

7068

SOLID CORE DOOR C/W WEATHER STRIPPING & SELF CLOSER

4'-2"

8080

5'-0"

3'-0"

12'-4"

2'-11"

3'-6"

2680

Range

2680

2'-5"

80 26

3R@5 21" 2T@10"

5'-1"

UP 2R@6 21"

SMOKE ALARM & CARBON MONOXIDE (CO) ALARM

5'-0"

2680

43'-6"

A A1

S CO

2680

2'-5"

5'-9"

8'-7"

1'-0"

Refrigerator

10'-2" 2680

2680

4'-6"

2630RS

2'-5" 1'-11" 9"

3060RS

2640RS

2'-0"

3060RS

OVEN/MW

10'-8"

2640RS

3040RS

5'-1" [1.55m]

2640RS

line of floor above

21068

3040RS

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

9'-11"

10'-17 8" [3.09m]

2'-7"

2640RS

2' [0.61m]

2630RS

5'-0"

1'-0"

5060RS

5060RS

main floor plan scale: 14" = 1'-0"

10'-1"

7'-6"

10'-1" 20'-1"

5'-2"

1'-6"1'-11"

3'-10"

12'-8"

3'-9"

12'-10"

34'-3"

1'-11" 1'-6"

3'-0"

2'-9"

7'-10"

4'-3"

7'-3"

5'-8"

17'-9" 25'-6"

10'-10" 70'-7"

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

SHEET TITLE:

HARJINDERPAL SINGH NAGRA PROJECT: CIVIC ADDRESS:13721 -56B St, SURREY, BC LEGAL DESCRIPTION: LOT 18 SECTION 9 TOWNSHIP 2

MAIN FLOOR PLAN

DRAWN BY:

G.S.M.

PROJECT NO.

CHECKED BY:

B.M.

169

DATE:

SEP. 2016

FILE NO.

SCALE:

1/4"=1'-0"

V12

SHEET NO:

A

2/7


61'-6"

2840RS

9'-10"

2'-1"

2840RS

2680

2840RS

1'-9" 1'-9"

2840RS

13

56

3'-11"

RS

13'-8"

4040 SKY LIGHT

43'-9" 1'-10"

2056RS 3680

A A1

2680

6'-11"

2680

2040RS

3080

6'-11"

4'-0"

2650RS

4030RS

6050RS

1'-2"

9'-4"

7'-9"

2626

17'-5"

2650RS

4'-4"

1'-5"

3040RS

1'-11" 5'-9"

2680

2680

1'-3"

4'-0"

Shower 3'6" x 5'0"

A A1

7'-9"

1'-3"1'-5" 1'-9"

2640RS

3680

3040RS

2640RS 2840RS

2680 2050RS

3680

2840RS

8'-10"

10'-3" 4'-5"

3040RS

16'-1" 9'-9"

39'-9"

BUILDING - INTERIOR DESIGNERS

2840RS

3'-8"

2680

UDC DESIGN CENTER LTD

10'-3"

2840RS

3'-8"

12'-8"

1'-9" 1'-9"

2'-1"

8'-11"

2680

1'-8" 2'-1"

13'-8"

2680

5'-7"

4'-0"

10'-11"

5'-5"

2680

2'-2"

5'-5"

12'-9"

2840RS

24'-4"

8050RS

4'-8"

4'-0"

2'-5" 1'-8"

17'-0"

5'-8"

12'-9"

5'-0"

3'-3" 8'-2"

22'-9"

8'-11"

8'-11" 17'-10"

61'-6"

upper floor plan

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

SHEET TITLE:

HARJINDERPAL SINGH NAGRA PROJECT: CIVIC ADDRESS:13721 -56B St, SURREY, BC LEGAL DESCRIPTION: LOT 18 SECTION 9 TOWNSHIP 2

UPPER FLOOR PLAN

DRAWN BY:

G.S.M.

PROJECT NO.

CHECKED BY:

B.M.

169

DATE:

SEP. 2016

FILE NO.

SCALE:

1/4"=1'-0"

V12

SHEET NO:

A

3/7


7'-018" [2.14m]

ROOF RIDGE LVL. 102.42 12 8

MEAN ROOF LVL. 100.28 7' [2.13m]

1

U/S CEILING LVL. 98.15

2

5

9'-214" [2.80m]

12

29'-6" [9.00m]

4

8 8

11'-214" [3.41m]

8

6 7 8

MAIN FL. LVL. 91.94 AVE. GRADE. LVL. 91.29

E.EL.91.51 P.EL.91.51 E.EL.91.06 P.EL.91.31

ROOF RIDGE LVL. 102.42 7'-018" [2.14m]

front elevation scale: 14" = 1'-0"

12 8

MEAN ROOF LVL. 100.28 12

7' [2.13m]

LIST OF MATERIALS

ASPHALT SHINGLE 40 YRS - IKO CAMBRIDGE, DUAL BLACK

2.

BUILT-IN GUTTER - METAL SOFFIT WITH 2" CONTINUOUS SCREENED VENT

3.

1 x 8 ON 2" X 10" FASCIA BOARD

4.

1" X 4" WOODEN TRIM

5.

STUCCO

6.

ALUMINUM FRAMED WINDOW AND PATIO DOOR

7.

WOODEN EXTERIOR DOOR

8.

STONE

9.

CEDAR SHAKE SIDING

U/S CEILING LVL. 98.15

9'-214" [2.80m]

1.

2650RS 12.5

right elevation

TOTAL AREA: 989 SQ. FT. ( 91.88 SQ.M.) scale: 14" = 1'-0" DISTANCE TO PROPERTY LINE: 25'-0" (7.62 M) ≈ 8.0M MAX. ALLOWABLE UNPROTECTED AREA @ 100% = 989 SQ. FT. ( 91.88 SQ. M.) PROPOSED UNPROTECTED AREA: 218.38 SQ. FT (20.28 SQ. M.)

2850RS

2650RS

2056RS 7

12.5

5-1356FX

2056RS 7

2850RS

10.5

10.5

5

29'-6" [9.00m]

SECOND FLOOR LVL. 95.35

RIGHT ELEVATION

16

5x6.875

12

5

8

8 8

11'-214" [3.41m]

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

SECOND FLOOR LVL. 95.35

3

8

12

5040RS 4670RS 27

8

4670RS 27

5-1380FX

20

5X10

MAIN FL. LVL. 91.94 AVE. GRADE. LVL. 91.29

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

E.EL.91.42 P.EL.91.52

E.EL.91.51 P.EL.91.51

SHEET TITLE:

HARJINDERPAL SINGH NAGRA PROJECT: CIVIC ADDRESS:13721 -56B St, SURREY, BC LEGAL DESCRIPTION: LOT 18 SECTION 9 TOWNSHIP 2

FRONT & RIGHT ELEVATION

DRAWN BY:

G.S.M.

PROJECT NO.

CHECKED BY:

B.M.

169

DATE:

SEP. 2016

FILE NO.

SCALE:

1/4"=1'-0"

V12

SHEET NO:

A

4/7


7'-018" [2.14m]

ROOF RIDGE LVL. 102.42 12 8

7' [2.13m]

MEAN ROOF LVL. 100.28

9'-214" [2.80m]

5

12

29'-6" [9.00m]

8

11'-214" [3.41m]

SECOND FLOOR LVL. 95.35

MAIN FL. LVL. 91.94

5

E.EL.91.42 P.EL.91.52

AVE. GRADE. LVL. 91.29

E.EL.91.17 P.EL.91.37

ROOF RIDGE LVL. 102.42 7'-018" [2.14m]

rear elevation

12 8

7' [2.13m]

MEAN ROOF LVL. 100.28

U/S CEILING LVL. 98.15

9'-214" [2.80m]

12

LEFT ELEVATION

TOTAL AREA: .741.74 SQ. FT. ( 69 SQ.M.) DISTANCE TO PROPERTY LINE: 25'-0" (7.62 M) ≈ 8.0M MAX. ALLOWABLE UNPROTECTED AREA @ 100% = 741.74 SQ. FT. ( 69 SQ.M.) PROPOSED UNPROTECTED AREA: 75.5 SQ. FT (7.01 SQ. M.)

3040RS 12

29'-6" [9.00m]

SECOND FLOOR LVL. 95.35

12

11'-214" [3.41m]

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

U/S CEILING LVL. 98.15

5

3040RS 12

2040RS 8

12 12

2630RS 7.5

10

10

5

4040RS 2640RS

2640RS 16

left elevation MAIN FL. LVL. 91.94 AVE. GRADE. LVL. 91.29

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

E.EL.91.17 P.EL.91.37

CLIENT:

E.EL.91.06 P.EL.91.31

SHEET TITLE:

HARJINDERPAL SINGH NAGRA PROJECT: CIVIC ADDRESS:13721 -56B St, SURREY, BC LEGAL DESCRIPTION: LOT 18 SECTION 9 TOWNSHIP 2

REAR AND LEFT ELEVATION

DRAWN BY:

G.S.M.

PROJECT NO.

CHECKED BY:

B.M.

169

DATE:

SEP. 2016

FILE NO.

SCALE:

V12

SHEET NO:

A

5/7


DUROID ROOF BUILDING PAPER ON 12" PLYWOOD ENG.TRUSSES @24" O/C R-40 BATT INSULATION 6 MIL POLY V.B. (LAPPED JOINTS,SEAL ELECT. OUTLETS) (WARM SIDE) 5 8" GYPSUM BOARD BUFFLES 2" CLEAR FROM TOP

7'-018" [2.14m]

12

MEAN ROOF LVL. 100.28 7' [2.13m]

8

ATTIC ATTIC VENTILATION AS PER BUILDINGCODE A/300 OF INSULATED CEILING AREA MIN. 25% OF VENTING @TOP & 25% @ BOTTOM

U/S CEILING LVL. 98.15

2

ROOF:

5

- ROOF FINISH: 210 # ASPHALT SHINGLES ROOF - STARTER STRIP - 716" OSB SHEATHING c/w. H. CLIPS - PREFAB. ENG. TRUSSES @ 24" O.C. - R-50 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.

2

EAVES:

- FINISH FLOOR: TO OWNERS SPEC'S - P.T. 2x10 @16 o.c. JOISTS AS PER MANUFACTURERS SPECS - 11/2"th. CONCRETE TOPPING - R-40 SPRAT FOAM INSULATION -5

6

TYPE "X" GYPSUM BOARD (FIN. AS PER OWNER)

SECOND FLOOR LVL. 95.35

BASEMENT FLOOR:

INTERIOR PARTITIONS ( 1 hr FRR): - 1/2" GYPSUM BOARD (BOTH SIDES) - 2 x 4 STUDS @ 16" O.C. - INSUALTED CAVITY

4

8"

- FINISH FLOOR: TO OWNERS SPEC'S - 0'-6" CONC. SLAB - 10 GA 6 x 6 WIRE MESH - 6 MIL. POLY. V.B. - R-10 RIGID INSULATION - MIN. 12" COMPACTED GRANULAR FILL

- BUILT-IN GUTTER - 2 x 12 FASCIA BOARD - METAL SOFFIT WITH 2" CONTINUOUS SCREENED VENT

3

MAIN FLOOR (1 hr FRR):

EXTERIOR WALLS (2 hr FRR): - STUCCO ON WIREMESH - METAL LATH - 19MM (3/4") AIR SPACE / @ 16" O.C. - 15# BREATHER TYPE BUILDING PAPER - 15 32" SHEATHING - 2 x 6 STUDS @ 16" O.C. - R-20 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

7

12 12

112" CONC. TOPPING

29'-6" [9.00m]

1

9'-214" [2.80m]

SECTIONAL DETAILS AND SPECIFICATIONS:

ND

FOUNDATION WALLS: - 2 x 6 SILL PLATE - 8" CONC. FOUNDATION WALL - 2 COATS OF ASHPALT EMULSION TO EXTERIOR FACE - 2 - 15M T & B, 10M @16" O.C E/W.1.F UP TO GRADE

INTERNAL INSULATED WALL

5

IL RA

4

HA

3'-

3

5 MAIN FL. LVL. 91.94

H

IG

H 0"

11'-214" [3.41m]

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

ROOF RIDGE LVL. 102.42

112" CONC. TOPPING

5

8" ANCHOR BOLTS @ 36" O.C.(TYOP)

2-15M CONTINUOUS

7

AVE. GRADE. LVL. 91.29

- 2" AIR SPACE - 2 x 4 SPF # 2 STUDS @ 24" O.C. (U.N.O.) - R-14 BATT. INSULATION - 6 MIL. POLY. V.B. - C/W TUCK TAPE JOINTS - 1/2" DRYWALL

CLIENT:

SHEET TITLE:

HARJINDERPAL SINGH NAGRA PROJECT: CIVIC ADDRESS:13721 -56B St, SURREY, BC LEGAL DESCRIPTION: LOT 18 SECTION 9 TOWNSHIP 2

SECTION

DRAWN BY:

G.S.M.

PROJECT NO.

CHECKED BY:

B.M.

169

DATE:

SEP. 2016

FILE NO.

SCALE:

1/4"=1'-0"

V12

SHEET NO:

A

6/7


ROOF PEAK EL. = 95.22

12 6

13'-2" [4.01m]

10'-8"

5'-4"

9' [2.74m]

STUCCO

5'-4"

STUCCO

SHED SLAB EL. = 91.20

SHED SLAB EL. = 91.20

WEST ELEVATION

12

NET FLOOR AREA = 108 SQ. FT.

9' [2.74m]

UNDER SIDE OF TRUSS EL. = 93.94

STUCCO

6

CENTER OF TRUSS EL. = 94.58 UNDER SIDE OF TRUSS EL. = 93.94

13'-2" [4.01m]

CENTER OF TRUSS EL. = 94.58

2'-1" [0.64m]

12 6

ROOF PEAK EL. = 95.22

STUCCO

SHED SLAB EL. = 91.20

EAST ELEVATION

13'-2" [4.01m]

ROOF PEAK EL. = 95.22

2'-1" [0.64m]

SHED

9' [2.74m]

10'-0"

2'-1" [0.64m]

2'-1" [0.64m]

NORTH ELEVATION

SHED SLAB EL. = 91.20

SOUTH ELEVATION

2'-1" [0.64m]

3

ENGINEERED TRUSSES @24 O.C. BY OTHERS

CENTER OF TRUSS EL. = 94.58

5

UNDER SIDE OF TRUSS EL. = 93.94

4 SHED 18'8"X9'8"

2

CONSTRUCTION SPECIFICATIONS

13'-2" [4.01m]

6

2'-1" [0.64m]

ROOF PEAK EL. = 95.22

12

9' [2.74m]

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

10'-8"

5016RS

SHED

UNDER SIDE OF TRUSS EL. = 93.94

13'-2" [4.01m]

UNDER SIDE OF TRUSS EL. = 93.94

+203.41

CENTER OF TRUSS EL. = 94.58

2'-1" [0.64m]

6 CENTER OF TRUSS EL. = 94.58

2868

18'8"X9'8"

ROOF PEAK EL. = 95.22

12

9' [2.74m]

WEATHERSTRIP SOLID CORE,

2'-1" [0.64m]

2'-1" [0.64m]

2'-0"

2'-1" [0.64m]

10'-0" 8'-0"

1 SHED SLAB EL. = 91.20

6

1. MAIN FLOOR SLAB -4" CONC. SLAB -6x6 WELDED WIRE MESH -6 MIL. POLY VAPOR BARRIER -6" MIN. COMPACTED SAND (TYPICAL)

4. EAVES

2. EXTERIOR WALLS STUCCO -#10 BUILDING PAPER -1/2" EXT. GRADE PLYWOOD SHEATHING -2x6 STUDS @ 16" o/c.(U.N.O.) -R20 F.G. BATT INSULATION -6 MIL POLY VAPOR BARRIER U.V.R. -1/2" GYPSUM BOARD

5. ATTIC VENTILATION

-5" ALUM. GUTTER -2x10 FASCIA BOARD -2x4 BACK NAILER -METAL SOFFIT WITH 2" CONT. SCREENED VENTILANT

-2" BAFFLE CLEARANCE WITH INSULATION STOPS 6. FOUNDATION -SEE FOUNDATION DETAIL

3. TRUSS ROOF -ASPHALT SHINGLE -BUILDING PAPER -1x4 STRAPPING -ENGINEERED TRUSSES @ 24" o/c(SEE TRUSS LAYOUT) -R-40 F.G. BATT INSULATION -6 MIL POLY VAPOR BARRIER -5/8" GYPSUM BOARD

SECTION B

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

SHEET TITLE:

HARJINDERPAL SINGH NAGRA PROJECT: CIVIC ADDRESS:13721 -56B St, SURREY, BC LEGAL DESCRIPTION: LOT 18 SECTION 9 TOWNSHIP 2

SHED DETAILS

DRAWN BY:

G.S.M.

PROJECT NO.

CHECKED BY:

B.M.

169

DATE:

SEP. 2016

FILE NO.

SCALE:

1 " 4

= 1'-0"

V12

SHEET NO:

A

7/7


BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

∙

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

SHEET TITLE:

HARJINDERPAL SINGH NAGRA PROJECT: CIVIC ADDRESS:13721 -56B St, SURREY, BC LEGAL DESCRIPTION: LOT 18 SECTION 9 TOWNSHIP 2

ENERGY DETAIL

DRAWN BY:

G.S.M.

PROJECT NO.

CHECKED BY:

B.M.

169

DATE:

SEP. 2016

FILE NO.

SCALE:

N.T.S.

V12

SHEET NO:

A


GRID

GRID

HEADER

EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

SEAL POLYETHYLENE (A.B. & V.B.) TO HOUSEWRAP (A.B.) 1/2"CONTROL JOINT FLOOR FINISH ON C/W CAULK AND ROD CONCRETE TOPPING

MIN. 3/8" GAP BETWEEN WINDOW & 1X2 STRAPPING

EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

4" ADHERED FLASHING MEMBRANE

INTERIOR

100 mm (4")

FLOOR FINISH ON CONCRETE TOPPING

SHEATHING PAPER BEHIND FLASHING AND INTO WINDOW OPENING INSECT SCREEN

MIN. 2% SLOPE TO DRAIN SEALANT JOINT AT VENT DUCT TO HOUSEWRAP (A.B.)

2"CONTINUOUS FLANGE AT PERIMETER OF HOOD

ROD AND SEALANT STUD @ 16" O.C

2"

2

SEALANT OR GASKET (A.B.) BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED

1 MIN 2"

BLDG. PAPER

4.06

23.03

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

3.99

22.61

0.68

4.11

23.29

ADHERED MEMBRANE FLASHING TO LAP 100mm (4") OVER SHEATHING PAPER BELOW

ROOF ASSEMBLY COMPONENTS (W/ ASPHALT SHINGLES) 1 ROOFING SHINGLES 2 POLYTHENE V.B 5 ″ (15.88 MM) OSB SHEATHING 3 8 4 2 x 10 JOISTS W/ R50 BATT @ 24″ O.C. 5 POLYETHYLENE 6 1/2″ (12.7 MM) GYPSUM BOARD 7 INTERIOR AIR FILM

RSI 0.077 0.00 0.136 8.8 0.00 0.08 0.12

R 0.44 0.00 0.77 50.0 0.00 0.45 0.68

SEALANT OR GASKET JOINT AT POLYETHYLENE (A.B. & V.B.) TO PLATE (A.B.)

2X10 FLOOR JOISTS

SEAL POLYETHYLENE (V.B.) TO SHEATHING PAPER (A.B.)

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

9.21

50.34

FLOOR ASSEMBLY OVER UNHEATED SPACE 1 EXTERIOR AIR FILM 2 FLOOR FINISHES (3 4" HARDWOOD) 3 POLYETHYLENE 4 512" CONC. SLAB 5 R-28 INSULATION 9 NATURAL GRADE

RSI 0.03 0.12 0.00 0.15 4.99 0.00

R 0.17 0.68 0.00 0.83 28.00 0.00

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

5.29

29.68

TRIPLE GLAZED WINDOWS & DOORS LOW E, DOUBLE GLAZED (6mm GAP), TEMPERED GLASS εn = 0.1, AIR FILLED WITH VINYL OR FIBRE GLASS FRAME

USI

U

1.4

0.246

1" 2

SEPERATION AIR SPACE

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

1 MIN.

PREFINISHED METAL FLASHING C/W END DAMS TO EXTEND 1" PAST END OF WINDOW FRAME

VENTED ALUMINUM SOFFIT PANELS EFFECTIVE RSI - 4.06 SEAL SHEATHING PAPER (A.B.) TO WINDOW FRAME REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

VALUES ADOPTED FROM CANADIAN WOOD COUNCIL

VALUES ADOPTED FROM CANADIAN WOOD COUNCIL

1.5" SILL PLATE

BUILDING - INTERIOR DESIGNERS

EXTERIOR STUCCO CLADDING

- HEAVY- DUTY POLYVINYL CHLORIDE (PVC )

INTERIOR

AIR SPACE W/ 1x2 TREATED WOOD STRAPPING SCREWED THROUGH INSULATION

THERMOPLASTIC WATER PROOFING MEMBRANES ARE OVERLAPPED AND HEAT FUSED ( APPLICATION CODE :CGSB -37-GP-55M)

SEALANT OR GASKET POLYETHYLENE TO PLATE (A.B.)

FLASHING & COUNTER FLASHING

SEALANT OR GASKET (A.B.)

ASPHALT IMPREGNATED PAPER

INSECT SCREEN - NO DAMPERS

EFFECTIVE RSI VALUE = 6.06 ROOFING SHINGLES (M.B.) WATERPROOF ROOF MEMBRANE (M.B.) FOR EAVE PROTECTION 5/8" OSB ROOF SHEATHING W/ H CLIPS WOOD ROOF FRAMING R-50 BATT INSULATION POLYETHYLENE (A.B. & V.B.) GYPSUM BOARD

GRID

1/2″ (12.7 MM) PLYWOOD SHEATHING

2 X 2 BLOCKING AT BOTH ENDS OF VENT 11/2" CONT. VENT

POLYETHYLENE VAPOR BARRIER

ADHERE SUBFLOOR TO HEADER (A.B.) FLOOR FINISH ON CONCRETE TOPPING

EFFECTIVE USI VALUE - 1.4 OPERABLE VINYL OR FIBERGLASS FRAME LOW ENERGY, DBL. GLAZED TEMP. GLASS W/ SLOPED SILL WEATHER STRIPPING

EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 (RSI-1.06)

1/2″ (12.7 MM) GYPSUM BOARD

MIN. 2% SLOPE TO DRAIN

2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. SLOPED SUB-SILL FRAMING

SEALANT OR GASKET (A.B.) REFER TO W-1 FOR EXTERNAL WALL ASSEMBLY DETAIL

INSULATION GUARD

POLYETHYLENE (V.B. AND A.B.) SEALANT OR GASKET (A.B.)

EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

GASKET (A.B.)

BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED

LAP POLYETHYLENE AND SEAL TO ADHERED MEMBRANE (A.B. AND V.B.)

W-1

SEALANT AND BACKER ROD JOINT AT WINDOW FRAME TO MEMBRANE (A.B. AND M.B.) SEALANT FILLET JOINT PREFINISHED METAL DRIP FLASHING

SEALANT BETWEEN POLYETHYLENE AND HOUSEWRAP (A.B.) FLOOR FINISH ON CONCRETE TOPPING

INTERMITTENT 1/8" P.T. SHIM BEHIND WINDOW FLANGE TO CREATE DRAINAGE PATH (ALTERNATELY DRILL HOLES OR SLOTS THROUGH WINDOW FLANGES TO TO ALLOW FOR DRAINAGE)

HOUSEWRAP AT HEADER (A.B.)

BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED GYPSUM BOARD

BATT INSULATION POLYETHYLENE (V.B.) STAPLED IN PLACE

25mm (1")

ADHERED MEMBRANE FLASHING (M.B.) SILL GASKET (A.B.)

CEMENT OR ACRYLIC STUCCO PARGING

EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

8" CONC. FOUNDATION WALL

FINISHED GRADE

4" EXTRUDED POLYSTYRENE R-5/in. 1" 2

REFER TO W-2/A-501 FOR FND WALL ASSEMBLY DETAIL

DRYWALL FINISH

912"

INSECT SCREEN

SEE 'FLASHING-BEST PRACTICE GUIDE' FOR ADDITIONAL ROOF FLASHING DETAILS

DAMP PROOFING / VAP. BARRIER

1/2"

2" MIN.

FILTER CLOTH

VENTED ALUMINUM SOFFIT PANELS

FLOOR OVER UNHEATED SPACE EFFECTIVE RSI 2.06

512"

CEMENT OR ACRYLIC STUCCO PARGING

8" MINIMUM

SHEATHING PAPER TO LAP OVER ADHERED MEMBRANE FLASHING

EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

SEAL HOUSEWRAP (A.B.) TO FRAMING

CONTINUE EAVE PROTECTION 12" BEYOND INSIDE FACE OF WALL

ADHERED MEMBRANE FLASHING TO EXTEND 4" AND LAP OVER SHEATHING PAPER

INTERIOR

COMPLETE W/ 4" EXTRUDED POLYSTYRENE FOAM BOARD INSUL. R-5/in.

WOOD FRAMING (STUDS OR STRAPPING)

W-2 UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

SHEET TITLE:

HARJINDERPAL SINGH NAGRA PROJECT: CIVIC ADDRESS:13721 -56B St, SURREY, BC LEGAL DESCRIPTION: LOT 18 SECTION 9 TOWNSHIP 2

GENERAL DETAIL

RSI R 0.03 0.17 0.035 0.20 1.06 6.00 0.00 0.00 0.11 0.62 2.55 14.49 0.00 0.00 0.08 0.45 0.00 0.00 0.12 0.68 .12

2a

2 SEALANT OR GASKET (A.B.)

EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

12mm (1/2")

SEAL POLYETHYLENE (A.B. & V.B.) TO HOUSEWRAP (A.B.)

1X2 STRAPPING

UDC DESIGN CENTER LTD

4" FLANGE

25.4mm (1")

R 0.17 0.62 6.00 0.00 0.62 14.49 0.00 0.45 0.00 0.68

WALL ASSEMBLY COMPONENTS (W/ STUCCO CLADDING) 1 EXTERIOR AIR FILM 3 " STUCCO FIN. 2 4 3 EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 4 ASPHALT IMPREGNATED PAPER2 5 1/2″ (12.7 MM) PLYWOOD SHEATHING 6 2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. 7 POLYETHYLENE 8 1/2″ (12.7 MM) GYPSUM BOARD 9 FINISH: 1 COAT LATEX PRIMER AND LATEX PAINT 10 INTERIOR AIR FILM

SHEATHING PAPER TO LAP METAL FLASHING

ROD AND SEALANT 1

RSI 0.03 0.11 1.06 0.00 0.11 2.55 0.00 0.08 0.00 0.12

VALUES ADOPTED FROM CANADIAN WOOD COUNCIL

4" FLANGE 6

WALL ASSEMBLY COMPONENTS (W/ NINYL CLADDING) 1 EXTERIOR AIR FILM 2 VINYL SIDING (NO AIR SPACE) 3 EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 4 ASPHALT IMPREGNATED PAPER 5 1/2″ (12.7 MM) PLYWOOD SHEATHING 6 2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. 7 POLYETHYLENE 8 1/2″ (12.7 MM) GYPSUM BOARD 9 FINISH: 1 COAT LATEX PRIMER AND LATEX PAINT 10 INTERIOR AIR FILM

EXTERIOR

4"

EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

RSI / R VALUE CALCULATIONS FOR ASSEMBLIES

EFFECTIVE USI VALUE - 1.4 OPERABLE VINYL OR FIBERGLASS FRAME LOW ENERGY, DBL. GLAZED TEMP. GLASS W/ SLOPED SILL WEATHER STRIPPING

GRID

DRAWN BY:

G.S.M.

PROJECT NO.

CHECKED BY:

B.M.

169

DATE:

SEP. 2016

FILE NO.

SCALE:

N.T.S.

V12

SHEET NO:

B