Lot 1 21963 dewdney trunk rd

Page 1

E.EL. 35.10 P.EL. 35.20 E.EL. 35.16 P.EL. 35.20

5'-3" [1.60m] RIGHT SETBACK

6' [1.83m]

37'-818" [11.48m]

E.EL. 35.49 P.EL. 35.66

E.EL. 35.21 P.EL. 35.66

20'-1" [6.11m]

52' [15.85m] BUILDING WIDTH

BUILDING - INTERIOR DESIGNERS

E.EL. 35.50 P.EL. 35.66

E.EL. 35.50 P.EL. 35.66

14'-9" [4.50m] FLANKING STREET LEFT SETBACK

UDC DESIGN CENTER LTD

25'-13 8" [7.66m]

38'-6" [11.74m] REAR SETBACK

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

64' [19.51m] BUILDING DEPTH

SHEET TITLE:

HERB KALSI PROJECT: CIVIC ADDRESS: 21963 DEWDNEY TRUNK ROAD, BC LEGAL DESCRIPTION: LOT #1 PID 010-157-468 LOT #2 PID 010-157-484

SITE PLAN, FLOOR PLANS & ELEVATIONS

25'-3" [7.70m] FRONT SETBACK

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

1278

DATE:

JULY. 2017

FILE NO.

SCALE:

1/8" = 1'-0"

V01

SHEET NO:

A1


SPECIFICATIONS AND GENERAL NOTES:

13 - PROVIDE FLASHING BETWEEN HORIZONTAL INTERSECTION OF DIFFERING WALL FINISHES.

SECTION 06100 ROUGH CARPENTRY LUMBER GRADES: AS SHOWN ON THE DRAWINGS AND / OR ACCORDING TO NLGA STANDARD GRADING RULES FOR CANADIAN LUMBER, MAXIMUM MOISTURE CONTENT 19%. ROOF SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR, METAL "H" CLIPS TO SUPPORT EDGES: 1/2" (12.5MM) FOR 16" (400MM) O/C SUPPORT; 5/8" (15.9MM) FOR 24" (600MM) O/C SUPPORT. INTERIOR FLOOR SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR OR SPRUCE. USE TO PLYWOOD WHERE REQUIRED BY STRUCTURAL DESIGN. FLOOR UNDERLAY: THREE PLY, 11/32" (8.5MM) THICK, SPRUCE PLYWOOD WITH THE FINISH FACE DOUBLE SANDED AND THE BACK FACE SLIGHTLY SANDED. THE CONTRACTOR MUST CONFIRM PRIOR TO INSTALLATION THE FLOORING UNDERLAY THAT IT IS ACCEPTABLE TO THE RESILIENT FLOORING MANUFACTURER. EXTERIOR DECK SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR, T&G. USE SELECT TIGHT FACE PLYWOOD UNDER PVC DECK WATERPROOFING. EXTERIOR WALL SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR OR SPRUCE. WOOD SIDING IF REQUIRED IN DESIGN: WESTERN RED CEDAR, KILN DRIED, SELECTED KNOTTY GRADE, BEVELED OR CHANNEL PATTERN, PRE-STAINED. FIBBER CEMENT EXTERIOR SIDING: NON COMBUSTIBLE FIBBER REINFORCED CEMENT HORIZONTAL SIDING. EXTERIOR FASCIAS AND TRIM: No.2, S-P-F, TEXTURED (COMBED) FINISH, PRE PRIMED FOR SOLID COLOR STAIN, NOT LESS THAN 2" (50MM) NOMINAL THICKNESS. SILL GASKET: CLOSED CELL POLYETHYLENE FOAM. GRAB BAR BLOCKING: 2" X 10" (38MM X 235MM). WOOD PRESERVATIVES: WOOD IN CONTACT WITH CONCRETE, MASONRY, AT ROOF UPSTANDS IN FLAT ROOFS, PLANTERS, HEAVY TIMBER CONSTRUCTION, FENCE POSTS AND CAVITY FURRING: PRESSURE TREATED MINIMUM 0.40 LB/FT2 TO CSA 080-M89, CLEAR, WATER BORNE, CHROMATE COPPER ARSENATE PRESERVERS BUREAU (CWPB) STAMPS. BOTTOM PLATE OF FRAME WALLS WITH SILL GASKETS DO NOT REQUIRE PRESSURE TREATING. USE HEM-FIR OR PINE INCISED LUMBER FOR TREATMENT. TREAT CUT SURFACES WITH TWO BRUSH OF COPPER NAPTHANATE PRESERVATIVE. EXECUTION: EXTERIOR WALL SILL PLATES: SET EXTERIOR WALL SILL PLATES ON FULL WIDTH STRIP OF FASCIA WINDOW TRIM, TRIM: INSTALL FASCIAS AND TRIMS IN LONGEST PRACTICAL LENGTHS, END JOINTS TO BE CUT IN 45 DEGREES AND LAPPED. FASTEN WITH HOT DIPPED GALVANIZED CASING NAILS AND COUNTERSINK. WOOD SIDING: INSTALL WALL CAVITY IF REQUIRED BY WALL DESIGN. USE LONGEST POSSIBLE LENGTHS TO MINIMIZE END JOINTS. INSTALL SIDING USING GALVANIZED SIDING OR CASING NAILS WITH RING OR SPRING SHANKS. DO NOT NAIL THROUGH OVERLAPPING PIECES. NAILS MUST BE LONG ENOUGH THAT THE NAIL PENETRATES THE FRAMING AT LEAST 1 1/4" (31.7MM). LAP BEVEL SIDING A MINIMUM OF 1" (25.4MM). SHIM BOTTOM EDGE OF SIDING TO PROVIDE A 1/8" (3MM) GAP BETWEEN IT AND THE SIDING BELOW. USE SOLID TRIMS AT INSIDE AND OUTSIDE CORNERS. BUTT SIDING INTO TRIMS. USE SOLID WOOD TRIMS AT THE INSIDE AND OUTSIDE CORNERS. BUTT SIDING INTO TRIMS.

SECTION 07200

18'-9"

SECTION 07300 ASPHALT SHINGLE AND CEDAR SHINGLE/SHAKES IF APPLICABLE PRODUCTS: ASPHALT SHINGLES: ACCEPTABLE MATERIALS AS LISTED IN THE RCABC ROOFING PRACTICES MANUAL, TAB 2" ACCEPTABLE MATERIALS LIST", LATEST EDITION. SHINGLE MATERIALS MAY BE ORGANIC OR FIBERGLAS CORE PRODUCT. FASTENER: NAILS MUST BE LARGE HEAD, CORROSION RESISTANT, (ELECTRO-GALVANIZED, HOT DIPPED GALVANIZED, ALUMINUM), ROOFING NAILS. METAL FLASHING: BASE AND COUNTER FLASHING AND COPING METAL TO BE SHEET STEEL, MINIMUM 26 GAUGE, GALVANIZED TO ASTM A525,ZF275 COATING, PRE FINISHED WITH STELCOLOUR 5000 SERIES PAINT FINISH. STEP FINISHING MUST BE 26 GAUGE IN ACCORDANCE WITH RCABC REQUIREMENTS. ACCESSORIES: INSTALL ZINC. STRIPS TO ASPHALT SHINGLE AT ALL RIDGE LOCATIONS. INSTALL ZINC STRIP MUST BE 2" (50MM) EXPOSED TO THE WEATHER. EAVES PROTECTION: SELF ADHESIVE RUBBERIZED ASPHALT SHEET INSTALLED TO BUILDING CODE REQUIREMENTS. ACCEPTABLE MATERIALS AS LISTED IN RCABC ROOFING MANUAL TAB 2" ACCEPTABLE MATERIAL LIST", LATEST EDITION. UNDERLAY: 1 PLY OF No. 15 NON PERFORATED ASPHALT FELT TO CSA A123.3M1979. EXECUTION: ASPHALT SHINGLE ROOFING MUST BE INSTALLED ACCORD. TO RCABC,STR-LS FOR LOW SLOPE ROOFS. INSTALL UNDERLAY ON ALL ROOF DECKS WHERE ASPHALT SHINGLES OF ANY TYPE ARE TO BE INSTALLED. UNDERLAY TO BE MINIMUM 1 PLY OF No. 15 NON PERFORATED FELT, LAPPED MINIMUM 3"(75MM) OR THE SPECIFIC SHINGLE MANUFATURER'S. RECOMMENDED UNDERLAY. THIS UNDERLAY IS ADDITIONAL TO ANY MATERIAL USED FOR EAVES PROTECTION AND SHOULD BE LAPPED OVER THE LEADING (TOP) EDGE OF THE EAVES PROTECTION. PROVIDE SLOPE TO DRAIN IN ALL GUTTER APPLICATIONS. WATERPROOF LINING FOR "HIDDEN" OR "INBOARD" OR PLY FULLY TORCHED TO FIRST PLY. "BUILT-IN" TYPE GUTTERS MUST BE FULLY ADHERED 2 PLY MODIFIED BITUMEN SHEETS AND MUST THE BASE SHEET INSTALLED UP THE SLOPE OF THE ROOF A MINIMUM OF 18" (450MM) HIGHER THAN TOP OF OUTBOARD SIDE ELEVATION OF THE GUTTER. THE CAP SHEET IS TO PROVIDE UV PROTECTION AND MUST BE INSTALLED IN ALL AREAS EXPOSED TO U.V. USE SELF ADHERING BASE SHEET WHENEVER POSSIBLE WITH SECOND UV PROTECTIVE ENSURE DRAINS DISCHARGE INTO DOWN SPOTS THAT ARE KEPT ABOVE FREEZING.

60'-3"

DWELLING SECURITY AS PER BCBC 2012 # 9.6.8

AIR BARRIER / SHEATHING MEMBRANE PRODUCT: TWO LAYERS OF 30 MINUTE ASPHALT SATURATED BUILDING PAPER CONFIRMING TO CAN-51.32M77 AND TO U.S. UUB-790a. EXECUTION: AIR BARRIER MEMBRANES MUST BE APPLIED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PRINTED INSTRUCTIONS AT ALL THE LOCATION IN THE EXTERIOR OF THE BUILDING ENVELOPE WHERE AIR IS FREE TO INFILTRATE THROUGH JOINTS IN COMPONENTS OF THE ASSEMBLIES AND AT JUNCTIONS WITH DISSIMILAR MATERIALS, CHANGES IN PLANE AND AT THE ROOF INSTALL SHEATHING MEMBRANE OVER EXTERIOR SHEATING. INSTALL ONE (1) LAYER OF ASPHALT SATURATED BUILDING PAPER HORIZONTALLY IN SUCCESSIVE STRIPS BEGINNING 2" (50MM) BELOW THE LOWEST POINT OF THE WALL FRAMING AND PROGRESSING UPWARDS WITH EACH SUCCEEDING SHEET. OVERLAP UPPER SHEET OVER LOWER SHEET A MINIMUM OF 4" (100MM) SO THAT LAPS ARE ARRANGED TO SHED WATER. END LAPS MUST HAVE A MINIMUM 12" (300MM) OVERLAP. STAGGER VERTICAL LAPS A MINIMUM OF 48" (1200MM). RETURN SHEET OVER FLASHINGS.

20'-4"

41'-6"

11- PRIOR TO FRAMING AND INSPECTION SUBMIT MECHANICAL VENTILATION/AIR CONDITIONING AND LETTER OF SUPERVISION B PROF.ENG.OR CERTIFIED H.R.A.I OR HVC TECHNICIAN.

SECTION 07270

NOTES FOR ROOF SPACE VENTILATION 1. 2.

UNIFORMLY DISTRIBUTE VENTILATION TO FLAT AND VAULTED ROOFS TO 1/150 OF INSULATED CEILING AREA. PROVIDE 2x2 CROSS PURLINS TO FLAT, VAULTED CEILINGS AND DECKS OVER LIVING AREAS.

3. 4. 5. 6. 7.

PROVIDE MIN. 2-1/2" CLEARANCE BETWEEN ROOF SHEATHING AND INSULATION. PROVIDE MIN. 1" CLEARANCE BETWEEN TOP OF ROOF JOIST AND INSULATION. VENTILATE ATTIC SPACES TO 1/300 OF INSULATED CEILING AREA. ROOF VENTS MUST BE UNIFORMLY DISTRIBUTED WITH A MIN. OF 25% IN EAVES AND 25% IN ROOF TOP. PROVIDE ATTIC ACCESS OF 1'-8" X 2'-4" AND WEATHER-STRIP HATCH.

2012 BCBC SECTION 9.36 REQUIREMENTS

2'-8"

8"

EXECUTION: EXTEND BOARDS A MINIMUM OF 24" (600MM) BELOW GRADE. 1. SERVICE WATER HEATING SYSTEM SHALL COMPLY WITH 2012 BCBC 9.36.4 2 THE DESIGN AND INSTALLATION OF THE HEATING , VENTILATION & AIR CONDITIONING SYSTEM SHALL COMPLY WITH INSTALL PERIMETER INSULATION USING MECHANICAL FASTENERS OR ADHESIVE. BUTT JOINT TIGHTLY, OFFSET REQUIREMENTS OF 2012 BCBC SECTION 9.36.3. HORIZONTAL AND VERTICAL JOINTS. USE LARGEST POSSIBLE SHEETS TO REDUCE NUMBER OF JOINTS. DO NOT 3. MECHANICAL , ELECTRICAL AND PLUMBING COMPONENTS PLACED WITHIN AN EXTERIOR WALL MUST BE INSULATED BEHIND TO THE EFFECTIVE THERMAL RESISTANCE SPECIFICATION SECTION 9.36.2.6. & 9.36.2.8. USE CHIPPED OR CRACKED INSULATION BOARDS. 4. CONSTRUCTION OF AIR BARRIER DETAILS SHALL COMPLY WITH 2012 BCBC 9.36.2.10. PROTECT INSULATION WITH PRESSURE TREATED PLYWOOD AND PRE FINISHED METAL CAP FLASHINGS. 5. THE LEAKAGE OF AIR INTO AND OUT OF CONDITIONED SPACES SHALL BE CONTROLLED BY CONSTRUCTING A INSULATION IN CAVITY WALLS: APPLY INSULATION IN CAVITY WALLS USING IMPALE TYPE CLIPS. FASTEN BOARDS CONTINUOUS AIR BARRIER SYSTEM AS SPECIFIED BCBC 9.36.2.9. 6. WALLS AND CEILINGS SEPARATING CONDITIONED SPACE FROM ATTACHED GARAGE ARE TO COMPLY WITH EFFECTIVE WITH A MINIMUM OF (4) FASTENERS PER 24" X 48" (600MM X 1200MM) BOARD. THERMAL RESISTANCE MINIMUM AS SPECIFIED IN SECTION 9.36.2.6. & 9.36.2.8. (EVEN IF GARAGE IS HEATED AND INSULATED) BATT INSULATION: INSTALL FULL WIDTH AND LENGTH BETWEEN STUDS AND FRAMING MEMBERS TO FIT SNUGLY WITHOUT BUCKLING, CREASING OR CRUSHING AS PER REQUIREMENTS OF BCBC 2012 SECTION 9.36.2.5. IN WALLS, INSTALL LOWER BATT FIRST; UPPER BUTT INSTALLED TO BUTT WITH THE FIRST AND ANY EXTRA LENGTH OF INSULATION TRIMMED AT TOP AS PER REQUIREMENTS OF BCBC 2012 SECTION 9.36.2.5. FIT INSULATION TIGHT TO ELECTRICAL BOXES, PLUMBING AND HEATING PIPES AND DUCTS, AROUND EXTERIOR DOORS AND WINDOWS AND OTHER PROTRUSIONS AS PER REQUIREMENTS OF BCBC 2012 SECTION 9.36.2.5. INSTALL INSULATION IN CONTINUOUS CONTACT WITH INTERIOR SHEATING AS PER REQUIREMENTS OF BCBC 2012 SECTION 9.36.2.5. ACCESS HATCHES: INSULATE ACCESS HATCHES TO THE SAME R VALUE AS THE ASSEMBLY IN WHICH THEY OCCUR.

21'-0"

1'-10"

ENGINEERED ROOF TRUSS DESIGN REQUIRED PRIOR TO INSTALLATION. PROVIDE 8" CLEARANCE BETWEEN GRADE AND SIDING.

16'-0"

21'-10"

4'-1"

WATERPROOF WALLBOARD REQUIRED AS TILE BASE AROUND TUBS AND SHOWERS AS PER BCBC 9.29.10.4. CEILING AND WALLS TO HAVE 6 mil U.V.POLY FULLY CAULKED AS PER 2012 BCBC 9.25.2.3 5/8" DRYWALL REQUIRED TO CEILING MEMBERS AT 24" O.C. AS PER 2012 BCBC 9.29.5.3. PROVIDE 5" GRAVEL AS PER BCBC 9.14.4.2 AND 6 mil U.V.POLY AS PER 2012 BCBC 9.13.6 UNDER SLAB A BOND BREAKING MATERIAL IS REQUIRED BETWEEN FOUNDATION AND SLABS DOORS BETWEEN GARAGE AND DWELLING TO BE A SOLID CORE, SELF CLOSING, WEATHER STRIPPED DOOR AS PER 2012 BCBC 9.10.13.15. THICKEN SLAB AT GARAGE ENTRY AS PER STRUCTURAL DRAWINGS. HEATING SYSTEM IS RADIANT HEAT FOR ALL FLOORS

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

GENERAL NOTES

12'-4"

19'-11"

SOFFITS: VENTED HARDISOFFIT

4'-4"

WINDOW TRIMS: HARDITRIM

50'-2"

5'-6"

EXTERIOR WINDOWS: ALUMINUM CLADDED WOOD FRAME OR VINYL FRAME

VAPOR BARRIER / VAPOR RETARDER TO BE INSTALLED AS PER REQUIREMENTS OF BCBC 2012 SECTION 9.36.2.9 & 9.36.2.10. PRODUCT: MATERIAL TO CONFORM TO CAN2-51.33-M80, TYPE II, 6 MIL IN WALLS. EXECUTION: APPLY VAPOR BARRIER TO WARM SIDE (INTERIOR SIDE) OF INSULATED WALLS. INSTALL VAPOR BARRIER TO PROTECT THE ENTIRE WALL SURFACE, INCLUDING FRAMING MEMBERS. APPLY VAPOR BARRIER HORIZONTALLY TO WALLS. LAP JOINTS MINIMUM OF 4" (100MM). SEAL TO FRAMING WITH ADHESIVE OR PRESSURE SENSITIVE TYPE. SEAL VAPOR BARRIER RETARDER TO PENETRATIONS.

26'-1"

2. EXTERIOR WALL FINISH: FINISH STUCCO , NATURAL OR CULTURED STONE

22'-11"

ROOF FINISH: ASPHALT SHINGLE

A-1

SECTION 07200

58'-10"

EXTERIOR BUILDING FINISH MATERIALS:

9'-0"

11'-0"

11'-0"

52'-0"

A-1 UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

SHEET TITLE:

HERB KALSI PROJECT: CIVIC ADDRESS: 21963 DEWDNEY TRUNK ROAD, BC LEGAL DESCRIPTION: LOT #1 PID 010-157-468 LOT #2 PID 010-157-484

FOUNDATION PLAN

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

1278

DATE:

JULY. 2017

FILE NO.

SCALE:

1/4"=1'-0"

V01

SHEET NO:

A2


A-1

A-1

50'-2" 12'-4"

11'-8" 7'-11"

4'-5"

50'-2" 16'-0"

10'-2"

6'-0"

5'-8"

5'-1"

5'-1"

17'-9"

14'-2" 9'-0"

7'-9"

8'-3"

18'-3" 8'-9"

3'-9"

5'-8"

5'-8"

3'-2"

3'-9"

UP 3R @ 7" 49'-4"

13'-7"

3068

13'-7"

6040RS

3040RS

5068

3040RS

3016RS

2668

51'-4"

3'-1"

2'-11" 2'-11" 1'-9" 10'-8"

4040FX

section-1

DN 17R @ 7"

5'-0"

7'-9"

2668

7068

U302490

5'-4"

2'-7"

2768

2668

9'-8"

Dishwasher

3030RS

14'-4" 7'-2"

4068

6'-6"

11'-11"

6840RS

section-1

2668

(CO) ALARM CARBON MONOXIDE SMOKE ALARM &

7'-7"

49'-7"

5'-5"

10'-2"

55'-8"

21068

21068

2668

4'-2" 21068

CO S

3030RS

14'-5"

3030RS

3'-0" 7'-2"

5'-8"

2'-8" 3'-0"

3016RS

2668

4'-5" 3'-6"

4040RS

5'-6"

4'-2"

S

5'-6"

2'-8" 2'-8" 5'-4"

2'-6"

2268

5'-6"

WH

2668

FIRE RATED WALL

1'-10"

9'-0"

21068

2668

6'-11"

14'-1"

5'-6" 8'-6" 5'-0"

2'-4"

13'-0"

3068

18'-9" 3040RS

6'-10"

31040RS

S

Inter Connected Door & Frame must have 208'-2" min. fire rated CW self closing

4'-7"

4'-1" 2668

4068

4'-10"

1'-0"

5068 2668

26'-4"

U242490R

(CO) ALARM CARBON MONOXIDE SMOKE ALARM &

FIRE RATED, SOLID CORE, WEATHER STRIPPED, SELF CLOSING DOOR

CO S

3'-0"

3068

5068

58'-10"

12038TS

S

6040RS

10'-10"

21'-0"

5'-0"

2'-9"

5'-3" 2'-0"

3040RS

21068

2668

2668

10'-11"

13'-8" 15'-8" 2'-11"

1'-2"

2668

5'-10"

3040RS

6040RS 8040TS

6'-7"

3'-11" 14'-5"

3'-11"

5'-10"

5'-8" 4'-3"

5'-5"

15'-9"

5'-6" 10'-11"

5'-6"

5'-6" 11'-0"

52'-0"

UP 3R @ 7" 5'-4"

9'-4"

8'-3"

11'-6" 2'-6"

1'-6"

1'-10"

2'-8" 4'-5"

1'-0"

2'-0"

S

2'-5"

6040RS

16080

2'-5"

8040FX 6040RS

6080

6040RS

2'-8"

14'-8"

2060FX

6'-3" 2668

14'-9"

12'-2"

22'-9"

4'-1"

16'-0"

UP 17R @ 7"

2060FX

5'-7"

16'-2"

2668

21068

2'-4" 4040RS

2668

21068

3'-8"

S

2668

2'-5"

9'-0"

3040RS

2'-0"

5068

21068

4068

2668

4'-8"

2'-4"

2668

8'-0"

5'-4"

3068

UP 3R @ 7"

S

2'-4"

5068

S

BUILDING - INTERIOR DESIGNERS

PONY WALL ELECTRICAL FIREPLACE AND TV

5'-6"

13'-9"

5'-6"

FIRE RATED WALL

S

UDC DESIGN CENTER LTD

6040RS

" -3 8'

9'-10"

4'-4"

8'-1"

8040RS

5'-4"

5'-6"

10'-9"

5'-6" 11'-0"

52'-0"

A-1

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

A-1

CLIENT:

SHEET TITLE:

HERB KALSI PROJECT: CIVIC ADDRESS: 21963 DEWDNEY TRUNK ROAD, BC LEGAL DESCRIPTION: LOT #1 PID 010-157-468 LOT #2 PID 010-157-484

MAIN AND TOP FLOOR

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

1278

DATE:

JULY. 2017

FILE NO.

SCALE:

1/4"=1'-0"

V01

SHEET NO:

A3


ROOF RIDGE LVL. 46.01

12

13'-014" [3.97m]

6

1

° 45

U/S CEILING LVL. 42.04

2 9

9

10

6340RS

10

6040RS

8040FX

8040TS

4 6 10

22'-115 8" [7.00m]

10'-23 8" [3.11m] 9' [2.74m] 20'-3" [6.17m] HIGHEST BLDG FACE (FINISHED GRADE)

34'-6" [10.51m]

SECOND FLOOR LVL. 39.30

6040RS

6040RS 6080

8

16080

MAIN FL. LVL. 36.19

E.EL. 35.49 P.EL. 35.66

AVE. GRADE. LVL. 35.50

E.EL. 35.50 P.EL. 35.66

ROOF RIDGE LVL. 46.01

FRONT ELEVATION

6

12

13'-014" [3.97m]

SCALE:1/8"-1' LIST OF MATERIALS

TILE ROOFING

2.

BUILT-IN GUTTER - METAL SOFFIT WITH 2" CONTINUOUS SCREENED VENT

3.

1 x 8 ON 2" X 10" FASCIA BOARD

4.

1" X 4" WOODEN TRIM

5.

STUCCO

6.

ALUMINUM FRAMED WINDOW AND PATIO DOOR

7.

WOODEN EXTERIOR DOOR

8.

STONE

9. HARDY PANEL 10. 2' X 2' HARDY PANEL

U/S CEILING LVL. 42.04

SECOND FLOOR LVL. 39.30

RIGHT ELEVATION RIGHT ELEVATION

TOTAL AREA: 1136 SQ. FT. [105 SQ.M] DISTANCE TO PROPERTY LINE: 6'0" (1.83 M) ≈ 2.0M MAX. ALLOWABLE UNPROTECTED AREA @ 8.0% = 90.88 SQ. FT. PROPOSED UNPROTECTED AREA: = 75.64 SQ. FT

MAIN FL. LVL. 36.19 AVE. GRADE. LVL. 35.50

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

3016RS

9

3040RS

4040FX

10'-23 8" [3.11m]

SCALE:1/8"-1'

9' [2.74m]

1.

34'-6" [10.51m]

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

3

3016RS

6840RS

3040RS

E.EL. 35.21 P.EL. 36.66

E.EL. 35.49 P.EL. 35.66

CLIENT:

SHEET TITLE:

HERB KALSI PROJECT: CIVIC ADDRESS: 21963 DEWDNEY TRUNK ROAD, BC LEGAL DESCRIPTION: LOT #1 PID 010-157-468 LOT #2 PID 010-157-484

FRONT AND RIGHT ELEVATION

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

1278

DATE:

JULY. 2017

FILE NO.

SCALE:

1/4"=1'-0"

V01

SHEET NO:

A4


ROOF RIDGE LVL. 46.01

12

13'-014" [3.97m]

6

45 °

MAIN FL. LVL. 36.19 AVE. GRADE. LVL. 35.50

3040RS

12038TS

3040RS

9

5068

22'-115 8" [7.00m]

21'-812" [6.62m] HIGHEST BLDG FACE (LOWEST EXISTING GRADE)

9' [2.74m] 10'-23 8" [3.11m]

34'-6" [10.51m]

SECOND FLOOR LVL. 39.30

8040RS

6040RS

6040RS

6040RS

3068

E.EL. 35.50 P.EL. 35.66

E.EL. 35.21 P.EL. 36.66

ROOF RIDGE LVL. 46.01

REAR ELEVATION 6

12

13'-014" [3.97m]

SCALE:1/8"-1'

SECOND FLOOR LVL. 39.30

LEFT ELEVATION LEFT ELEVATION TOTAL AREA: 989 SQ. FT. [91 SQ.M] DISTANCE TO PROPERTY LINE: 14'9" (4.50 M) ≈ 6.0M MAX. ALLOWABLE UNPROTECTED AREA @ 34.0% = 336.26 SQ. FT. PROPOSED UNPROTECTED AREA: 98.32 SQ. FT

3030RS

MAIN FL. LVL. 36.19

3030RS 3040RS

3040RS

2568

9

10'-23 8" [3.11m]

SCALE:1/8"-1'

9' [2.74m]

U/S CEILING LVL. 42.04

34'-6" [10.51m]

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

U/S CEILING LVL. 42.04

3030RS 31040RS

4040RS

3068

4040RS

E.EL. 35.50 P.EL. 35.66

E.EL. 35.50 P.EL. 35.66

3068

AVE. GRADE. LVL. 35.50

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

SHEET TITLE:

HERB KALSI PROJECT: CIVIC ADDRESS: 21963 DEWDNEY TRUNK ROAD, BC LEGAL DESCRIPTION: LOT #1 PID 010-157-468 LOT #2 PID 010-157-484

REAR AND LEFT ELEVATION

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

1278

DATE:

JULY. 2017

FILE NO.

SCALE:

1/4"=1'-0"

V01

SHEET NO:

A5


ROOF RIDGE LVL. 46.01

DUROID ROOF BUILDING PAPER ON 12" PLYWOOD ENG.TRUSSES @24" O/C R-40 BATT INSULATION 6 MIL POLY V.B. (LAPPED JOINTS,SEAL ELECT. OUTLETS) (WARM SIDE) 5 8" GYPSUM BOARD BUFFLES 2" CLEAR FROM TOP

13'-014" [3.97m]

1 6

12

ATTIC ATTIC VENTILATION AS PER BUILDINGCODE A/300 OF INSULATED CEILING AREA MIN. 25% OF VENTING @TOP & 25% @ BOTTOM

2 U/S CEILING LVL. 42.04 1'-6" [0.46m] 1'-4" [0.41m] 16" STUD OC

9' [2.74m]

2668

4068

21068

3

10'-23 8" [3.11m]

34'-6" [10.51m]

SECOND FLOOR LVL. 39.30

TYP.CELLAR FLR. ASSEMBLY 1 " GYPSUM BOARD 2 FLR. JOINTS @ 16" o.c. AS ER STRUC. ENG. 26682668 5 " T&G PLYWOOD SUBFLOOR 8 RADIANT HEATING PIPES ON WIRE MESH 1- 12" LIGHT WEIGHT CONC. TOPPING FLOOR FINISH

3068

21068

2668

2060FX

21068

2060FX

BUILDING - INTERIOR DESIGNERS

RADIANT HEATING PIPES ON WIRE MESH

5

MAIN FL. LVL. 36.19 AVE. GRADE. LVL. 35.50

DRAINAGE: DRAIN ROCK 4" AGR DR. TILE @ FTG.

SECTION A-1 F5(D): -SUBFLOOR OF 15.5mm PLYWOOD, OSB OR WAFERBOARD OR 17mm TONGUEAND GROOVE LUMBER -38mm(121")X 235mm(914") WOODFLOOR JOISTS -ABSORPTIVE MATERIAL IN CAVITY -METAL FURRING CHANNELS SPACED 600mm O.C. -15.9mm(58") TYPE X GYPSUM BOARD

SCALE:1/8"-1' SECTIONAL DETAILS AND SPECIFICATIONS: 5

- ROOF FINISH: 210 # ASPHALT SHINGLES ROOF - STARTER STRIP - 716" OSB SHEATHING c/w. H. CLIPS - PREFAB. ENG. TRUSSES @ 24" O.C. - R-50 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.

2

EAVES:

- FINISH FLOOR: TO OWNERS SPEC'S - P.T. 2x10 @16 o.c. JOISTS AS PER MANUFACTURERS SPECS - 11/2"th. CONCRETE TOPPING - R-40 SPRAT FOAM INSULATION

6

- FINISH FLOOR: TO OWNERS SPEC'S - 0'-6" CONC. SLAB - 10 GA 6 x 6 WIRE MESH - 6 MIL. POLY. V.B. - R-10 RIGID INSULATION - MIN. 12" COMPACTED GRANULAR FILL

4

EXTERIOR WALLS (2 hr FRR): - STUCCO ON WIREMESH - METAL LATH - 19MM (3/4") AIR SPACE / @ 16" O.C. - 15# BREATHER TYPE BUILDING PAPER - 15 32" SHEATHING - 2 x 6 STUDS @ 16" O.C. - R-20 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.

7

LESS THAN 7'-6"

0"

0"

7'-6" TO 8'-0"

18"

20"

8'-1" TO 9'-0"

14"

20"

9'-1" TO 10'-0"

12"

20"

5 8" ANCHOR BOLT @ 48" o.c. (MAX. OF 1 PLATE UNDER JOIST.)

GARAGE SLAB OR FINISHED GRADE

VERTICAL STEEL = 'A' (ALTERNATE HOOKS)

- 2 x 6 SILL PLATE - 8" CONC. FOUNDATION WALL - 2 COATS OF ASHPALT EMULSION TO EXTERIOR FACE - 2 - 15M T & B, 10M @16" O.C E/W.1.F UP TO GRADE

MAX. COVER 2" HORIZONTAL STEEL = 'B' (LAP JOINTS 18" MINIMUM) APPLY DAMPROOFING AS REQ. BY N.B.C. SECT.9-13

INTERNAL INSULATED WALL

4" CONC. SLAB ON 6 MIL. POLY. V.B. ON 6" COMPACTED GRANULAR FILL

8" REINFORCED CONCRETE FOUNDATION WALL

- 2" AIR SPACE - 2 x 4 SPF # 2 STUDS @ 24" O.C. (U.N.O.) - R-14 BATT. INSULATION - 6 MIL. POLY. V.B. - C/W TUCK TAPE JOINTS - 1/2" DRYWALL

24"

FLOOR JOIST W1(C): -38mm(121")X 89mm(312") STUDS SPACED 400mm OR 600mm -WITH 89mm THICK ABSORPTIVE MATERIAL -15.9mm(5 8") TYPE X GYPSUM BOARD

W1(C): -38mm(112")X 89mm(321") STUDS SPACED 400mm OR 600mm -WITH 89mm THICK ABSORPTIVE MATERIAL -15.9mm(5 8") TYPE X GYPSUM BOARD

5

8" TYPE "X" GYPSUM BOARD ON BOTH SIDES CONTINUOUS TO UNDERSIDE OF FLOOR SHEATHING (HATCHED AREA)

F.R.R WALL DETAIL

30 MIN. F.R.R. ASSEMBLY DETAIL

212" RIGID INSULATION (N.I.C.) TO BELOW FROSTLINE OR 2x4 FURRED WALL w/ R12 F.G. BATT INSUL. (N.I.C.) WHERE INDICATED

FOUNDATION WALLS:

A

EXTERIOR WALL CONSTRUCTION

TYPICAL FLOOR CONSTRUCTION

2" FROM GARAGE SLAB OR SIDEWALK 8" MIN. FROM FINISH GRADE

BASEMENT FLOOR:

INTERIOR PARTITIONS ( 1 hr FRR): - 1/2" GYPSUM BOARD (BOTH SIDES) - 2 x 4 STUDS @ 16" O.C. - INSUALTED CAVITY

B

NOTE: 1. REBAR TO BE 230 MPa MINIMUM. 2. CONCRETE TO BE 20 MPa MINIMUM. 3. BACKFILL NOT TO EXCEED 20 KN/ cubic METER

- 5 8" TYPE "X" GYPSUM BOARD (FIN. AS PER OWNER)

- BUILT-IN GUTTER - 2 x 12 FASCIA BOARD - METAL SOFFIT WITH 2" CONTINUOUS SCREENED VENT

3

MAIN AND UPPER FLOOR (1 hr FRR):

A

NET BACKFILL HEIGHT

ROOF:

NET BACKFILL HT.

SUBFLOOR

NOTCH OUT 12" TYPE "X" GYPSUM BOARD FOR FLOOR JOISTS

5

8"

TYPE "X" GYPSUM BOARD AGAINST SEPARATION WALL

F5(D): -SUBFLOOR OF 15.5mm PLYWOOD, OSB OR WAFERBOARD OR 17mm TONGUEAND GROOVE LUMBER -38mm(112")X 235mm(914") WOODFLOOR JOISTS -ABSORPTIVE MATERIAL IN CAVITY -METAL FURRING CHANNELS SPACED 600mm O.C. -15.9mm(58") TYPE X GYPSUM BOARD

-METAL FURRING CHANNELS SPACED 600mm O.C. -15.9mm (58") TYPE X GYPSUM BOARD

15M @ 15" o.c. 8"

4"Ø PERIMETER DRAIN TILE WITH DRAIN ROCKS

ON PLAN

1

SUPPORTED WALL (10M BAR)

AS NOTED

UDC DESIGN CENTER LTD

4

DETAIL AT 'A'

F.R.R. CEILING DETAIL

2-15M CONT. AS NOTED ON PLAN

SUPPORTED WALL SECTION UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

SHEET TITLE:

HERB KALSI PROJECT: CIVIC ADDRESS: 21963 DEWDNEY TRUNK ROAD, BC LEGAL DESCRIPTION: LOT #1 PID 010-157-468 LOT #2 PID 010-157-484

SECTION

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

1278

DATE:

JULY. 2017

FILE NO.

SCALE:

1/4"=1'-0"

V01

SHEET NO:

A6


BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

∙

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

SHEET TITLE:

HERB KALSI PROJECT: CIVIC ADDRESS: 21963 DEWDNEY TRUNK ROAD, BC LEGAL DESCRIPTION: LOT #1 PID 010-157-468 LOT #2 PID 010-157-484

ENERGY DETAIL

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

1278

DATE:

JULY. 2017

FILE NO.

SCALE:

N.T.S.

V01

SHEET NO:

A7


GRID

GRID GRID

HEADER

EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

SEAL POLYETHYLENE (A.B. & V.B.) TO HOUSEWRAP (A.B.) 1/2"CONTROL JOINT FLOOR FINISH ON C/W CAULK AND ROD CONCRETE TOPPING

MIN. 3/8" GAP BETWEEN WINDOW & 1X2 STRAPPING

EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

4" ADHERED FLASHING MEMBRANE

INTERIOR

100 mm (4")

FLOOR FINISH ON CONCRETE TOPPING

SHEATHING PAPER BEHIND FLASHING AND INTO WINDOW OPENING INSECT SCREEN

MIN. 2% SLOPE TO DRAIN SEALANT JOINT AT VENT DUCT TO HOUSEWRAP (A.B.)

2"CONTINUOUS FLANGE AT PERIMETER OF HOOD

STUD @ 16" O.C

2"

2

SEALANT OR GASKET (A.B.) BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED

1 MIN 2"

BLDG. PAPER

4.06

23.03

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

3.99

22.61

0.68

4.11

23.29

ADHERED MEMBRANE FLASHING TO LAP 100mm (4") OVER SHEATHING PAPER BELOW

ROOF ASSEMBLY COMPONENTS (W/ ASPHALT SHINGLES) 1 ROOFING SHINGLES 2 POLYTHENE V.B 5 ″ (15.88 MM) OSB SHEATHING 3 8 4 2 x 10 JOISTS W/ R50 BATT @ 24″ O.C. 5 POLYETHYLENE 6 1/2″ (12.7 MM) GYPSUM BOARD 7 INTERIOR AIR FILM

RSI 0.077 0.00 0.136 8.8 0.00 0.08 0.12

R 0.44 0.00 0.77 50.0 0.00 0.45 0.68

SEALANT OR GASKET JOINT AT POLYETHYLENE (A.B. & V.B.) TO PLATE (A.B.)

2X10 FLOOR JOISTS

SEAL POLYETHYLENE (V.B.) TO SHEATHING PAPER (A.B.)

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

9.21

50.34

FLOOR ASSEMBLY OVER UNHEATED SPACE 1 EXTERIOR AIR FILM 2 FLOOR FINISHES (3 4" HARDWOOD) 3 POLYETHYLENE 4 512" CONC. SLAB 5 R-28 INSULATION 9 NATURAL GRADE

RSI 0.03 0.12 0.00 0.15 4.99 0.00

R 0.17 0.68 0.00 0.83 28.00 0.00

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

5.29

29.68

TRIPLE GLAZED WINDOWS & DOORS LOW E, DOUBLE GLAZED (6mm GAP), TEMPERED GLASS εn = 0.1, AIR FILLED WITH VINYL OR FIBRE GLASS FRAME

USI

U

1.4

0.246

SEPERATION AIR SPACE

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

1 MIN.

RSI R 0.03 0.17 0.035 0.20 1.06 6.00 0.00 0.00 0.11 0.62 2.55 14.49 0.00 0.00 0.08 0.45 0.00 0.00 0.12 0.68 .12

1" 2

2a

2 SEALANT OR GASKET (A.B.)

EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

12mm (1/2")

SEAL POLYETHYLENE (A.B. & V.B.) TO HOUSEWRAP (A.B.)

1X2 STRAPPING

VALUES ADOPTED FROM CANADIAN WOOD COUNCIL

PREFINISHED METAL FLASHING C/W END DAMS TO EXTEND 1" PAST END OF WINDOW FRAME

VENTED ALUMINUM SOFFIT PANELS EFFECTIVE RSI - 4.06 SEAL SHEATHING PAPER (A.B.) TO WINDOW FRAME REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

VALUES ADOPTED FROM CANADIAN WOOD COUNCIL

1.5" SILL PLATE

BUILDING - INTERIOR DESIGNERS

EXTERIOR STUCCO CLADDING

- HEAVY- DUTY POLYVINYL CHLORIDE (PVC )

INTERIOR

AIR SPACE W/ 1x2 TREATED WOOD STRAPPING SCREWED THROUGH INSULATION

THERMOPLASTIC WATER PROOFING MEMBRANES ARE OVERLAPPED AND HEAT FUSED ( APPLICATION CODE :CGSB -37-GP-55M)

SEALANT OR GASKET POLYETHYLENE TO PLATE (A.B.)

FLASHING & COUNTER FLASHING

SEALANT OR GASKET (A.B.)

ASPHALT IMPREGNATED PAPER

INSECT SCREEN - NO DAMPERS

EFFECTIVE RSI VALUE = 6.06 ROOFING SHINGLES (M.B.) WATERPROOF ROOF MEMBRANE (M.B.) FOR EAVE PROTECTION 5/8" OSB ROOF SHEATHING W/ H CLIPS WOOD ROOF FRAMING R-50 BATT INSULATION POLYETHYLENE (A.B. & V.B.) GYPSUM BOARD

GRID

1/2″ (12.7 MM) PLYWOOD SHEATHING

2 X 2 BLOCKING AT BOTH ENDS OF VENT 11/2" CONT. VENT

POLYETHYLENE VAPOR BARRIER

ADHERE SUBFLOOR TO HEADER (A.B.) FLOOR FINISH ON CONCRETE TOPPING

EFFECTIVE USI VALUE - 1.4 OPERABLE VINYL OR FIBERGLASS FRAME LOW ENERGY, DBL. GLAZED TEMP. GLASS W/ SLOPED SILL WEATHER STRIPPING

EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 (RSI-1.06)

1/2″ (12.7 MM) GYPSUM BOARD

MIN. 2% SLOPE TO DRAIN

2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. SLOPED SUB-SILL FRAMING

SEALANT OR GASKET (A.B.) REFER TO W-1 FOR EXTERNAL WALL ASSEMBLY DETAIL

INSULATION GUARD

POLYETHYLENE (V.B. AND A.B.) SEALANT OR GASKET (A.B.)

EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

GASKET (A.B.)

BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED

LAP POLYETHYLENE AND SEAL TO ADHERED MEMBRANE (A.B. AND V.B.)

W-1

SEALANT AND BACKER ROD JOINT AT WINDOW FRAME TO MEMBRANE (A.B. AND M.B.) SEALANT FILLET JOINT PREFINISHED METAL DRIP FLASHING

SEALANT BETWEEN POLYETHYLENE AND HOUSEWRAP (A.B.) FLOOR FINISH ON CONCRETE TOPPING

INTERMITTENT 1/8" P.T. SHIM BEHIND WINDOW FLANGE TO CREATE DRAINAGE PATH (ALTERNATELY DRILL HOLES OR SLOTS THROUGH WINDOW FLANGES TO TO ALLOW FOR DRAINAGE)

HOUSEWRAP AT HEADER (A.B.)

BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED GYPSUM BOARD

BATT INSULATION POLYETHYLENE (V.B.) STAPLED IN PLACE

25mm (1")

ADHERED MEMBRANE FLASHING (M.B.) SILL GASKET (A.B.)

2" MIN.

FILTER CLOTH

CEMENT OR ACRYLIC STUCCO PARGING

SEE 'FLASHING-BEST PRACTICE GUIDE' FOR ADDITIONAL ROOF FLASHING DETAILS

DAMP PROOFING / VAP. BARRIER EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

8" CONC. FOUNDATION WALL

FINISHED GRADE

4" EXTRUDED POLYSTYRENE R-5/in. 1" 2

REFER TO W-2/A-501 FOR FND WALL ASSEMBLY DETAIL

DRYWALL FINISH

912"

INSECT SCREEN

VENTED ALUMINUM SOFFIT PANELS

FLOOR OVER UNHEATED SPACE EFFECTIVE RSI 2.06

512"

CEMENT OR ACRYLIC STUCCO PARGING

8" MINIMUM

SHEATHING PAPER TO LAP OVER ADHERED MEMBRANE FLASHING

EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

SEAL HOUSEWRAP (A.B.) TO FRAMING

CONTINUE EAVE PROTECTION 12" BEYOND INSIDE FACE OF WALL

ADHERED MEMBRANE FLASHING TO EXTEND 4" AND LAP OVER SHEATHING PAPER

INTERIOR

1/2"

UDC DESIGN CENTER LTD

ROD AND SEALANT

4" FLANGE

25.4mm (1")

R 0.17 0.62 6.00 0.00 0.62 14.49 0.00 0.45 0.00 0.68

WALL ASSEMBLY COMPONENTS (W/ STUCCO CLADDING) 1 EXTERIOR AIR FILM 3 " STUCCO FIN. 2 4 3 EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 4 ASPHALT IMPREGNATED PAPER2 5 1/2″ (12.7 MM) PLYWOOD SHEATHING 6 2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. 7 POLYETHYLENE 8 1/2″ (12.7 MM) GYPSUM BOARD 9 FINISH: 1 COAT LATEX PRIMER AND LATEX PAINT 10 INTERIOR AIR FILM

SHEATHING PAPER TO LAP METAL FLASHING

ROD AND SEALANT 1

RSI 0.03 0.11 1.06 0.00 0.11 2.55 0.00 0.08 0.00 0.12

VALUES ADOPTED FROM CANADIAN WOOD COUNCIL

4" FLANGE 6

WALL ASSEMBLY COMPONENTS (W/ NINYL CLADDING) 1 EXTERIOR AIR FILM 2 VINYL SIDING (NO AIR SPACE) 3 EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 4 ASPHALT IMPREGNATED PAPER 5 1/2″ (12.7 MM) PLYWOOD SHEATHING 6 2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. 7 POLYETHYLENE 8 1/2″ (12.7 MM) GYPSUM BOARD 9 FINISH: 1 COAT LATEX PRIMER AND LATEX PAINT 10 INTERIOR AIR FILM

EXTERIOR

4"

EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

RSI / R VALUE CALCULATIONS FOR ASSEMBLIES

EFFECTIVE USI VALUE - 1.4 OPERABLE VINYL OR FIBERGLASS FRAME LOW ENERGY, DBL. GLAZED TEMP. GLASS W/ SLOPED SILL WEATHER STRIPPING

COMPLETE W/ 4" EXTRUDED POLYSTYRENE FOAM BOARD INSUL. R-5/in.

WOOD FRAMING (STUDS OR STRAPPING)

W-2 UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

SHEET TITLE:

HERB KALSI PROJECT: CIVIC ADDRESS: 21963 DEWDNEY TRUNK ROAD, BC LEGAL DESCRIPTION: LOT #1 PID 010-157-468 LOT #2 PID 010-157-484

GENERAL DETAIL

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

1278

DATE:

JULY. 2017

FILE NO.

SCALE:

N.T.S.

V01

SHEET NO:

A8