HLD Plastic anchors Economical plastic anchor for drywall Anchor version
Benefits - Plastic undercut anchor - Simple setting HLD (M10)
- Drywall application
Base material
Drywall
Basic loading data All data in this section applies to: Correct setting (See setting instruction) No edge distance and spacing influence Base material as specified in the table Load data given in the tables is independent of load direction
Characteristic resistance Anchor size Anchoring principle Gypsum board Thickness 12,5mm Fibre reinforced gypsum board Thickness 12,5mm Fibre reinforced gypsum board Thickness 2x12,5mm Hollow clay brick Concrete ≥ C16/20 a)
HLD 4
FRk
[kN]
0,4
0,4
0,4
A
FRk
[kN]
0,3
-
-
A
FRk
[kN]
-
0,6
-
A/B C
FRk FRk
[kN] [kN]
0,75 1,25
0,75 2
2,5
HLD 2
HLD 3
HLD 4
See setting details
Anchoring principle Gypsum board Thickness 12,5mm Fibre reinforced gypsum board Thickness 12,5mm Fibre reinforced gypsum board Thickness 2x12,5mm Hollow clay brick Concrete ≥ C16/20
1
HLD 3
B
Design resistance Anchor size
a)
HLD 2 a)
a)
B
FRd
[kN]
0,11
0,11
0,11
A
FRd
[kN]
0,08
-
-
A
FRd
[kN]
-
0,17
-
A/B C
FRd FRd
[kN] [kN]
0,21 0,35
0,21 0,56
0,70
See setting detail
Updated: Dec-17
Recommended loads b) Anchor size Anchoring principle Gypsum board Thickness 12,5mm Fibre reinforced gypsum board Thickness 12,5mm Fibre reinforced gypsum board Thickness 2x12,5mm Hollow clay brick Concrete ≥ C16/20 a) b)
HLD 2
HLD 3
HLD 4
a)
B
FRec
[kN]
0,08
0,08
0,08
A
FRec
[kN]
0,06
-
-
A
FRec
[kN]
-
0,12
-
A/B C
FRec FRec
[kN] [kN]
0,15 0,25
0,15 0,4
0,5
See setting details With overall global safety factor = 5 to the characteristic loads and a partial safety factor of = 1,4 to the design value.
Materials Material quality Part Sleeve
Material Polyamide PA 6
Setting information Installation temperature -10°C to + 40°C Service temperature range Hilti HLD universal anchor may be applied in the temperature range given below. Temperature range
Base material temperature
Max. long term base material temperature
Max. short term base material temperature
Temperature range
-40 °C to +80 °C
+50 °C
+80 °C
Max short term base material temperature Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of diurnal cycling. Max long term base material temperature Long-term elevated base material temperatures are roughly constant over significant periods of time.
Setting details Anchor size Nominal diameter of drill bit Depth of drill hole Screw length Screw diameter
Wall / panel thickness
Updated: Dec-17
HLD 2 (only anchoring principle C) (anchoring principle A/B) (anchoring principle C) (anchoring principle A/B) (anchoring principle C) (anchoring principle A) (anchoring principle B) (anchoring principle C)
do h1 ≥ ls ls ds ds h h h
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
50 33 + tfix 40 + tfix
4 – 12 12 – 16 35
HLD 3 10 56 40 + tfix 46 + tfix 4-5 5-6 15 – 19 19 – 25 42
HLD 4 66 49 + tfix 56 + tfix
24 - 28 28 - 32 50
2
Installation equipment Anchor size Rotary hammer Other tools
HLD 2
HLD 3 TE 2- TE16 Screwdriver
HLD 4
Setting instruction *For detailed information on installation see instruction for use given with the package of the product. Setting instruction 1.Drill hole with drill bit 2.Install anchor
3.Install anchor
3
4.Drive in the screw
Updated: Dec-17
Updated: Dec-17
4