Tæknilegar Upplýsingar fyrir HUS3 Redundant Steinskrúfur

Page 1

HUS3 redundant SCREW ANCHOR Technical Datasheet Update: Dec-18


HUS3 Screw anchor Ultimate performance screw anchor for redundant fastening applications Anchor version

Benefits HUS3-H/HF (6-10)

-

Quick and easy setting

-

Low expansion forces in base materials

HUS-HR (6)

-

Removable

-

Forged-on washer and hexagon head with no protruding thread

HUS3-C (6-10) -

ETA approval for cracked and non cracked concrete and for hollow

HUS-CR (6)

core slabs -

High productivity – less drilling and fewer operations than with

HUS3-A (6)

conventional anchors HUS3-PL (6)

Through-fastening and pre-setting (based on the head configuration)

HUS3-P (6)

HUS3-PS (6)

HUS3-I (6)

HUS3-I Flex (6)

Base material

Concrete (non-cracked)

Load conditions

Concrete (cracked)

Solid brick

Autoclaved aerated concrete

Prestressed hollow core slabs

Static / quasi-static

Fire resistance

Installation conditions

Other information

Small edge distance and spacing

European Technical Assessment

1

CE conformity

Corrosion resistance

Updated: Dec-18


Approvals / certificates Description European Technical Assessment Fire test report a)

Authority / Laboratory DIBt, Berlin DIBt, Berlin

No. / date of issue ETA-10/0005 / 2018-11-12 ETA-10/0005 / 2018-11-12

All data given in this section according ETA-10/0005 issue 2018-11-12

Basic loading data (for a single anchor) All data in this section applies to: - Correct setting (See setting instruction) - No edge distance and spacing influence - Concrete C 20/25, fck,cube = 25 N/mm² Anchorage depth HUS1) HR, CR 30

Type Nominal embedmt.depth 1) 2)

hnom

[mm]

HUS2) HR,CR 35

HUS32) H,P,PS,I,I-Flex,A,C 35

Hilti Technical Data for embedment depth of 30 mm ETA-10/0005 issue 2018-11-12

Characteristic resistance for all loads directions HUS1) HR,CR

Type Fastener size 35 mm ≤ c < 80 mm c > 80 mm 1) 2)

6 all lenghts F0Rk [kN] F0Rk

[kN]

2 2

HUS2) HR,CR 6x40 6x60 6x45 6x70 3 3,5 5

HUS32) H,PL,P,PS,I,I-Flex,A,C

HUS2)

HUS32) H,PL,P,PS,I,I-Flex,A,C

6 all lengths 2 3

Hilti Technical Data for embedment depth of 30 mm ETA-10/0005 issue 2018-11-12

Design resistance for all loads directions HUS1) HR,CR

Type Fastener size 35 mm ≤ c < 80 mm c > 80 mm 1) 2)

6 all lenghts F0Rd [kN] F0Rd

[kN]

1 1

HR 6x40 6x45

CR 6x60 6x70 1,4

1,7

2,4

6 all lengths 1,3 2,0

Hilti Technical Data for embedment depth of 30 mm ETA-10/0005 issue 2018-11-12

Recommended loads for all load directions HUS1) HR,CR

Type Fastener size 35 mm ≤ c < 80 mm c > 80 mm 1) 2) 3)

6 all lenghts F0Rec [kN] F0Rec

[kN]

0,7 0,7

HUS2) HR 6x40 6x45

CR 6x60 6x70 1,0

1,2

1,7

HUS32) H,PL,P,PS,I,I-Flex,A,C 6 all lengths 0,9 1,4

Hilti Technical Data for embedment depth of 30 mm ETA-10/0005 issue 2018-11-12 With overall partial safety factor for action  = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national regulations

Updated: Dec-18

2


Requirements for redundant fastening The definition of redundant fastening according to Member States is given in the EAD 330747 § 1.2.1. In Absence of a definition by a Member State the following default values may be taken. Minimum number Minimum number of anchors per Maximum design load of action of fixing points fixing point NSd per fixing pointa) 3 1 2 kN 4 1 3 kN a)

The value for maximum design load of actions per fastening point NSd is valid in general that means all fastening points are considered in the design of the redundant structural system. The value NSd may be increased if the failure of one (=most unfavourable) fixing point is taken into account in the design (serviceability and ultimate limit state) of the structural system e.g. suspended ceiling.

Materials Mechanical properties HUS HR,CR 1040 22,9 15,5 12,9

Type Nominal tensile strength fuk Stressed cross-section As Moment of resistance W Design bending resistance M0Rd,s

[N/mm2] [mm2] [mm3] [Nm]

HUS3 H,PL,P,PS,I,I-Flex,A,C 930 26,9 19,7 14,6

Material quality Type HUS3- H,A,C,P,PS,I,I-Flex HUS- HR,CR

Material Carbon steel, galvanized ≥ 5 µm Stainless steel, grade A4

Anchor dimensions HUS HR,CR

Type Nominal length

ls

[mm]

40-70

Threaded outer diameter Core diameter Shaft diameter Diameter of integrated washer Stressed section

dt dk ds di As

[mm] [mm] [mm] [mm] [mm2 ]

7,6 5,4 5,8 22,9

3

H 40120

16,5

C

A

40-70 35-55

-

-

PL 60

HUS3 P

I-Flex 5540-80 40-60 35-55 195 7,85 5,85 6,15 26,9

PS

I

-

-

-

-

Updated: Dec-18


Special anchor dimensions Type

HUS3-C M6 M8 M10

HUS-CR M6 M8 M10

PL

HUS3P

PS

Countersunk heigt

hc

[mm]

4,0

6,3

6,9

4,3

6,3

7,0

-

-

-

Diameter of the countersunk

dc

[mm]

11,5

18

21

11,5

18

21

-

-

-

Pan head diameter

dp

[mm]

-

-

-

-

-

-

21,8

17,6

13,3

Head configuration Type Head HUS3-H 6

HUS-HR 6

Hexagonal head

Hexagonal head

HUS3-C 6

Countersunk head

HUS-CR 6

Countersunk head

HUS3-A 6

External thread

HUS3-PL

Pan head (large)

HUS3-P

Pan head

HUS3-PS 6

Pan head (small)

HUS3-I 6

Internal thread

HUS3-I Flex 6

External thread

Updated: Dec-18

4


Setting information

Setting details HUS HR CR

Type Nominal diameter of drill bit Cutting diameter of drill bit Clearance hole diameter Wrench size Installation torque Depth of drill fole in floor/wall position Depth of drill fole in ceiling position 1)

H

C

HUS3 P PL

A

d0 dcut ≤ df SW Tinst

[mm] [mm] [mm] [mm] 13 [mm] -1)

h1≥

[mm]

45 mm

h1≥

[mm]

38 mm

PS

I

I-Flex

13

13

6 6,40 9 -1)

13

-

13

18

-

Hand setting in concrete base material not allowed (machine setting only).

Setting parameters HUS-HR, CR HUS3-H, PL, P, PS, I, I-Flex, A, C

Type Minimum base material thickness Minimum spacing Minimum edge distance Critical spacing Critical edge distance 1)

5

hmin smin cmin scr ccr

[mm] [mm] [mm] [mm] [mm]

80 35 35(80)1) 3 hef 1,5 hef

For spacing (edge distance) smaller than critical spacing (critical edge distance ) the design loads have to be reduced (see system design resistance ).

Updated: Dec-18


Screw length and maximum thickness of fixture Fastener size

6 HUS

Type

HR

CR

H

C

Nominal embedment depth [mm]

Length of screw [mm]

HUS3 PL P PS

A

PS

I

IFlex

5 25 -

0 20 -

20 100 120 140 160

hnom Thickness of fixture [mm] tfix 10 25 35 -

35 40 45 55 60 70 80 100 120 135 155 175 195

5 25 35 -

5 25 45 65 85 -

5 25 35 -

0 20 -

25 -

5 25 45 -

Installation equipment Type Torx size TX Rotary hammer Drill bit Wrench size (H, A, I-type) SW Socket wrench insert (H, A, I-type) Impact screw driver Tinst

-

HUS HR CR - T30

[mm] 13 [mm]

-

H T30

13

HUS3 C A PL P PS T30 T30 T30 T30 TE 6 – TE 7 TE-CX 6 13 S-NSD 13 ½ (L) Hilti SIW 14-A /Hilti SIW 22-A

I -

I-Flex -

13

13

Setting parameters HUS-HR, CR HUS3-H, PL, P, PS, I, I-Flex, A, C

Type Minimum base material thickness spacing Minimum Minimum edge distance Critical spacing Critical edge distance 2)

hmin smin cmin scr ccr

[mm] [mm] [mm] [mm] [mm]

80 35 35(80)1) 3 hef 1,5 hef

For spacing (edge distance) smaller than critical spacing (critical edge distance ) the design loads have to be reduced (see system design resistance ).

Updated: Dec-18

6


Setting instructions *For detailed information on installation see instruction for use given with the package of the product Setting instruction for HUS-HR,CR 1. Drill hole with the drill bit 2. Clean hole

3. Installing the anchor by impact screw driver

Setting instruction for HUS3-H, C, I, I-Flex, A, P, PS 1. Drill hole with drill bit

3. Installing the anchor by impact screw driver

4. Checking

2. Clean hole

4. Checking

The anchor can be adjusted max. two times. The total allowed thickness of shims added during the adjustment process is 10 mm. The final embedment depth after adjustment process must be larger or equal than hnom2 or hnom3.

7

Updated: Dec-18


Basic loading data for redundant fastening in prestresed hollow core slabs All data in this section applies to: Correct anchor setting (See setting instruction) No edge distance and spacing influence Ratio core width/web thickness w/e ≤ 4,2 Concrete C 30/37 to C50/56 Data for size 6 is according to ETA-10/0005 - Data for size 8 and 10 is according to Hilti technical data

Requiretements for redundant fastening The definition of redundant fastening according to Member States is given in the EAD 330747 § 1.2.1. In Absence of a definition by a Member State the following default values may be taken. Minimum number Minimum number of anchors per Maximum design load of action of fixing points fixing point NSd per fixing pointa) 3 1 2 kN 4 1 3 kN a)

The value for maximum design load of actions per fastening point NSd is valid in general that means all fastening points are considered in the design of the redundant structural system. The value NSd may be increased if the failure of one (=most unfavourable) fixing point is taken into account in the design (serviceability and ultimate limit state) of the structural system e.g. suspended ceiling.

Characteristic resistance for all load directions Type Bottom flange thickness All load directions

db FRk

[mm] [kN]

HUS-HR,CR

HUS-HR, CR

6x40, 6x45 ≥ 25 ≥ 30 1,0 2,0

6x60, 6x70 ≥ 25 ≥ 30 ≥ 35 1,0 2,0 3,0

HUS-HR,CR

HUS-HR, CR

HUS3-H, PL, P, PS, I, I-Flex, A, C 6 all lengths ≥ 25 ≥ 30 ≥ 35 1,0 2,0 3,0

Design resistance for all load directions Type Bottom flange thickness All load directions

db FRd

[mm] [kN]

6x40, 6x45 ≥ 25 ≥ 30 0,7 1,3

≥ 25 0,7

6x60, 6x70 ≥ 30 ≥ 35 1,3 2,0

HUS3-H, PL, P, PS, I, I-Flex, A, C 6 all lengths ≥ 25 ≥ 30 ≥ 35 0,7 1,3 2,0

Recommended load for all load directions a) Type Bottom flange thickness All load directions a)

db FRec

[mm] [kN]

HUS-HR,CR

HUS-HR, CR

6x40, 6x45 ≥ 25 ≥ 30 0,5 1,0

6x60, 6x70 ≥ 25 ≥ 30 ≥ 35 0,5 1,0 1,4

HUS3-H, PL, P, PS, I, I-Flex, A, C 6 all lengths ≥ 25 ≥ 30 ≥ 35 0,5 1,0 1,4

With overall partial safety factor for action  = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national regulations.

Updated: Dec-18

8


Characteristic resistance for all load directions Anchor size Type Bottom flange thickness db ≥ [mm] All load directions

FRk

FRd

FRec

a) With overall partial safety factor for action national regulations.

2,0

2,0

8 HUS3-C, H, HF 30

10 HUS3-C, H, HF 30

1,3

1,3

8 HUS3-C, H, HF 30

10 HUS3-C, H, HF 30

0,95

0,95

[kN]

Recommended loads for all load directions Anchor size Type Bottom flange thickness db ≥ [mm] All load directionsa)

10 HUS3-C, H, HF 30

[kN]

Design resistance for all load directions Anchor size Type Bottom flange thickness db ≥ [mm] All load directions

8 HUS3-C, H, HF 30

[kN]

 = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from

Setting information Setting details Anchor size

6 1)

HUS

Type Effective anchorage depth Bottom flange thickness Nominal diameter of drill bit Cutting diameter of drill bit Nominal depth of drill hole4) Clearance hole diameter Distance between anchor and prestressing steel Core distance Pre-stressing steel distance Installation torque

HR

CR

HUS-HR, CR2) HUS3-H, PL, P, PS, I, I-Flex, A, C

hef db ≥ d0 dcut ≤ h1 ≥ df

[mm] [mm] [mm] [mm] [mm] [mm]

25 25 6 6,4 38 9

ap ≥

[mm]

50

lc ≥ lp ≥ Tinst

[mm] [mm] [mm]

100 100 -3)

18

1) Hilti Technical Data for embedment depth of 30 mm 2) ETA-10/0005 issue 2018-11-12 3) Hand setting in concrete base material not allowed (machine setting only) 4) Nominal depth of drill hole may be deeper than bottom flange thickness

9

Updated: Dec-18


Anchor size Type HUS3-C, H, HF Effective anchorage depth hef [mm] 30 Bottom flange thickness db ≥ [mm] 30 Nominal diameter of drill bit d0 [mm] 8 Cutting diameter of drill bit dcut ≤ [mm] 8,45 Nominal depth of drill hole1) h1 ≥ [mm] 40 Clearance hole diameter df [mm] 12 Distance between anchor and ap ≥ [mm] 50 prestressing steel Core distance lc ≥ [mm] 100 Pre-stressing steel distance lp ≥ [mm] 100 1) Nominal depth of drill hole may be deeper than bottom flange thickness

8 HUS3-C, H, HF 30 30 10 10,45 40 14 50 100 100

Screw length and thickness of fixture used in precast pre-stressed hollow core slabs for size 6 Anchor size

6 HUS

Type

HR

H

C

Nominal embedment depth [mm]

Length of screw [mm]

A

PL PS

HUS3 P

PS

I

I-Flex

hnomd Thickness of fixture [mm] tfix

35 40 45 55 60 70 80 100 120 135 155 175 195

Updated: Dec-18

CR

15 5-25 15-35 -

5-25 15-35 -

5 5 5-25 5-25 15-35 25-45 45-65 65-85 -

0 0 5 5 20 20 - 5-25 5-25 5-25 25-45 -

20 80-100 100-120 120-140 140-160

10


Screw length and thickness of fixture used in precast pre-stressed hollow core slabs for size 8 Anchor Type

Size

Length

[mm]

[mm]

HUS3-H

8

HUS3-HF

8

HUS3-C

8

HUS3-H

10

HUS3-HF

10

HUS3-C

10

11

55 65 75 85 100 120 150 65 75 85 100 65 75 85 60 70 80 90 100 110 130 150 60 80 100 110 70 90 100

db=30 [mm] tfix,min tfix,max

db=35 [mm] tfix,min tfix,max

db=40 [mm] tfix,min tfix,max

db=50 [mm] tfix,min tfix,max

[mm]

[mm]

[mm]

[mm]

[mm]

[mm]

[mm]

[mm]

5 5 5 15 30 50 80 5 5 15 30 15 15 15 5 15 5 5 15 25 45 65 5 5 15 25 15 15 15

15 25 35 45 60 80 110 25 35 45 60 25 35 45 15 25 35 45 55 65 85 105 15 35 55 65 25 45 55

5 5 5 15 30 50 80 5 5 15 30 15 15 15 5 15 5 5 15 25 45 65 5 5 15 25 15 15 15

10 20 30 40 55 75 105 20 30 40 55 20 30 40 10 20 30 40 50 60 80 100 10 30 50 60 20 40 50

5 5 5 15 30 50 80 5 5 15 30 15 15 15 5 15 5 5 15 25 45 65 5 5 15 25 15 15 15

5 15 25 35 50 70 100 15 25 35 50 15 25 35 5 15 25 35 45 55 75 95 5 25 45 55 15 35 45

5 5 5 15 30 50 80 5 5 15 30 15 15 15 5 15 5 5 15 25 45 65 5 5 15 25 15 15 15

5 5 15 25 40 60 90 5 15 25 40 5 15 25 5 5 15 25 35 45 65 85 5 15 35 45 10 25 35

Updated: Dec-18


Anchor spacing and edge distance HUS-HR, CR HUS3-H, PL,P, PS, I, I-Flex, A, C

Type Minimum edge distance

cmin ≥

[mm]

100

Minimum anchor spacing

smin ≥

[mm]

100

Minimum distance between anchor groups

amin ≥

[mm]

100

c1, c2 s1, s2 a1, a2

edge distance Anchor spacing Distances between anchor groups

Updated: Dec-18

12


Setting instructions *For detailed information on installation see instruction for use given with the package of the product Installation in hollow core slabs 1. Checking the anchor with tube Hilti HSB 2. Positioning pre-stressed steel

13

3. Marking pre-stressed steel position

4. Marking pre-stressed steel position

5. Drilling

6. Setting the anchor

7. Setting the anchor

8. Checking

Updated: Dec-18