Tæknilegar Upplýsingar fyrir HIF Einangrunarfestingar

Page 1

HIF Insulation fastener Anchor version

Benefits -

HIF

Especially for soft insulation material Plate diameter 90mm is ideal not to sink in the surface No slip-on plate must be used Drilling, hammering, done Speed due to less drilling effort With anchors up to 240mm insulation thickness the whole application is covered

Base material

Concrete (non-cracked)

Solid brick

Hollow brick

Autoclaved aerated concrete

Other information

Fastening of insulation at the wall only

Basic loading data (for a single anchor) All data in this section applies to: Correct setting (see setting instruction) No edge distance and spacing influence Base material as specified in table Minimum base material thickness Tensile loads only Recommended loads Base material Concrete ≥ C16/20 Solid clay brick Mz 20 – 1,8 – NF Solid sand-lime brick KS 12 – 1,6 – 2DF Hollow clay brick c) Hlz 12 – 0,8 – 6DF Hollow sand-lime brick c) KSL 12 – 1,4 – 3DF Autoclaved aerated concrete AAC 4

NRd

[kN]

HIF 0,03

NRd

[kN]

0,03

NRd

[kN]

0,03

NRd

[kN]

0,025 b)

NRd

[kN]

0,03

NRd

[kN]

0,015

b)

a) Recommended loads Nrec are based on an global safety factor  = 3 to the characteristic resistance. Design resistance NRd can be derived by multiplying Nrec with a partial safety factor of F = 1,5. b) Drilling without hammer action c) Thickness of web for Hlz ≥ 18mm, for KSL ≥ 25mm

1

Updated: Jan-18


Point thermal transmittance Point thermal transmittance  [W/K] 0,000 a)

Base material Insulation a) According EOTA Technical Report TR 025

Fire classification According to DIN 4102 EN 13501-1

Classification B2 E-d2

Service temperature range Base material temperature Temperature range

-40 °C to +40 °C

Maximum long term base material temperature +24 °C

Maximum short term base material temperature +40 °C

Maximum short term base material temperature Short-term elevated base material temperatures are those that occur over brief intervals, e.g. because of diurnal cycling. Maximum long term base material temperature Long-term elevated base material temperatures are roughly constant over significant periods of time. Materials Material quality Part Anchor shaft and anchor plate

Material Polypropylene

Setting information

Updated: Jan-18

2


Setting details HIF Nominal diameter of drill bit Cutting diameter of drill bit Depth of drill hole Overall plastic anchor embedment depth in the base material Anchor length Fixture thickness

60

80

120

140

160

d0

[mm]

8

dcut ≤

[mm]

8,45

h1 ≥

[mm]

La - lD + 5 ≥ 30mm

hnom ≥

[mm]

25

La

[mm]

lD

[mm]

Installation temperature Exposure to UV

85 4060

105 6080

125 80100

145 100120

[°C]

165 120140

185 140160

180

200

220

240

205 160180

225 180200

245 200220

265 220240

0 to +40 ≤ 6 weeks

Installation equipment Anchor size

HIF Corded: HILTI TE 2 – TE 7 Battery: HILTI TE2-A22, TE4-A22, TE6-A36 Hammer

Rotary hammer Other tools

Setting parameters HIF Minimum base material thickness Minimum spacing Minimum edge distance

100

60

80

100

120

140

160

hmin

[mm]

100

smin cmin

[mm] [mm]

100 100

180

200

220

240

Setting instruction* *For detailed information on installation see instruction for use given with the package of the product. Setting instructions 1. Drill hole with drill bit 2. Tap fastener with a hammer

3. Check correct setting

3

Updated: Jan-18


Updated: Jan-18

4


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.