HIF Insulation fastener Anchor version
Benefits -
HIF
Especially for soft insulation material Plate diameter 90mm is ideal not to sink in the surface No slip-on plate must be used Drilling, hammering, done Speed due to less drilling effort With anchors up to 240mm insulation thickness the whole application is covered
Base material
Concrete (non-cracked)
Solid brick
Hollow brick
Autoclaved aerated concrete
Other information
Fastening of insulation at the wall only
Basic loading data (for a single anchor) All data in this section applies to: Correct setting (see setting instruction) No edge distance and spacing influence Base material as specified in table Minimum base material thickness Tensile loads only Recommended loads Base material Concrete ≥ C16/20 Solid clay brick Mz 20 – 1,8 – NF Solid sand-lime brick KS 12 – 1,6 – 2DF Hollow clay brick c) Hlz 12 – 0,8 – 6DF Hollow sand-lime brick c) KSL 12 – 1,4 – 3DF Autoclaved aerated concrete AAC 4
NRd
[kN]
HIF 0,03
NRd
[kN]
0,03
NRd
[kN]
0,03
NRd
[kN]
0,025 b)
NRd
[kN]
0,03
NRd
[kN]
0,015
b)
a) Recommended loads Nrec are based on an global safety factor = 3 to the characteristic resistance. Design resistance NRd can be derived by multiplying Nrec with a partial safety factor of F = 1,5. b) Drilling without hammer action c) Thickness of web for Hlz ≥ 18mm, for KSL ≥ 25mm
1
Updated: Jan-18
Point thermal transmittance Point thermal transmittance [W/K] 0,000 a)
Base material Insulation a) According EOTA Technical Report TR 025
Fire classification According to DIN 4102 EN 13501-1
Classification B2 E-d2
Service temperature range Base material temperature Temperature range
-40 °C to +40 °C
Maximum long term base material temperature +24 °C
Maximum short term base material temperature +40 °C
Maximum short term base material temperature Short-term elevated base material temperatures are those that occur over brief intervals, e.g. because of diurnal cycling. Maximum long term base material temperature Long-term elevated base material temperatures are roughly constant over significant periods of time. Materials Material quality Part Anchor shaft and anchor plate
Material Polypropylene
Setting information
Updated: Jan-18
2
Setting details HIF Nominal diameter of drill bit Cutting diameter of drill bit Depth of drill hole Overall plastic anchor embedment depth in the base material Anchor length Fixture thickness
60
80
120
140
160
d0
[mm]
8
dcut ≤
[mm]
8,45
h1 ≥
[mm]
La - lD + 5 ≥ 30mm
hnom ≥
[mm]
25
La
[mm]
lD
[mm]
Installation temperature Exposure to UV
85 4060
105 6080
125 80100
145 100120
[°C]
165 120140
185 140160
180
200
220
240
205 160180
225 180200
245 200220
265 220240
0 to +40 ≤ 6 weeks
Installation equipment Anchor size
HIF Corded: HILTI TE 2 – TE 7 Battery: HILTI TE2-A22, TE4-A22, TE6-A36 Hammer
Rotary hammer Other tools
Setting parameters HIF Minimum base material thickness Minimum spacing Minimum edge distance
100
60
80
100
120
140
160
hmin
[mm]
100
smin cmin
[mm] [mm]
100 100
180
200
220
240
Setting instruction* *For detailed information on installation see instruction for use given with the package of the product. Setting instructions 1. Drill hole with drill bit 2. Tap fastener with a hammer
3. Check correct setting
3
Updated: Jan-18
Updated: Jan-18
4