IDP Insulation fastener Anchor version
Benefits - for insulation up to 15 cm - simple setting IDP
Base material
Concrete (non-cracked)
Solid brick
Hollow brick
Other information
Fastening of insulation at the wall only
Basic loading data (for a single anchor) All data in this section applies to: Correct setting (see setting instruction) No edge distance and spacing influence Base material as specified in table Minimum base material thickness Loads shall be reduced and number of fasteners shall be increased if temperature sustains above 40°C Recommended loads a) Base material Concrete ≥ C16/20 Solid clay brick Mz 20 – 1,8 – NF Solid sand-lime brick KS 12 – 1,6 – 2DF Hollow clay brick Hlz 12 – 0,8 – 6DF Hollow sand-lime brick KSL 12 – 1,4 – 3DF a) b)
1
Nrec
[kN]
IDP 0,14
Nrec
[kN]
0,14
Nrec
[kN]
0,14
Nrec
[kN]
0,04b)
Nrec
[kN]
0,04
With overall global safety factor = 5 to the characteristic loads and a partial safety factor of = 1,4 to the design values. Drilling without hammering
Updated: Jan-18
Materials Material quality Part Anchor with plate
Material Polypropylene
Setting information Setting details
Anchor size Nominal diameter Cutting diameter of drill bit Depth of drill hole Nominal anchorage depth Anchor length Maximum thickness of fixture Installation temperature Installation equipment Anchor size Rotary hammer Other tools
d0 dcut ≤ h1 ≥ hnom
[mm] [mm] [mm] [mm]
l
[mm]
tfix
[mm] [°C]
0/2
2/4
50 20
70 40
4/6
6/8 8/10 8 8,45 l - tfix + 10mm ≥ 40mm 25 90 110 130 60 80 100 0 up to 40
10/12
13/15
150 120
180 150
IDP Corded: HILTI TE 2 – TE 7 Battery: HILTI TE2-A22, TE4-A22, TE6-A36 Hammer
Setting instruction* *For detailed information on installation see instruction for use given with the package of the product.
Updated: Jan-18
2