X-IE-H DATA SHEET
Insulation fastener for hard board
July 2020
2163704 A2 23.11.2016
A2 6
X-IE-H
X-IE X-IE-H
X-IE-H Insulation fastener for hard board Product data
1
Dimensions
General information
X-IE-H X-IE-H Ø 60mm
Ø 60mm
Material specifications
X-IE-6
Nail:
5a
Carbon steel shank: HRC 58
5a
Zinc coating:
>5°C Recommended fastening tools
7 8
2
40
>5°C
40
90°
5b
/
days
X-460-FIE-L
/V
Ø 60mm
7
5–20 μm
1
max.
X-IE-H
HDPE, white
max. DX 460 IE, DX 460 IE XL, DX 5 IE, DX 5 IE XL See X-IE fastener program in the next pages and Tools and equipment for more290° details. 8 1 days chapter
3
Plate:
X-IE-6
2
X-IE-H
X-460-FIE-XL 5b
9
X-IE-KC
50 Ø 60mm
60 X-460-FIE-L
X-460-FIE-XL
9
X-IE-KC
80 6
100 4
Applications and suitable insulation materials PIR, PUR
Multilayer
XPS
Wool, EPS
PIR, PUR
Multilayer
XPS
Wool, EPS
Barriers: All materials are suitable
10
6
DX 460 DX 5
6.8/ 11 DFTM
6.8 /11
6.8 / 11 DX 460 DX 5
10
6.8 /11
DFTM
Insulation behind curtain walls
Insulation in ceilings
Temporary fixing of insulation of moisture barriers / drainage plates
In general: the fastener is intended to be used with insulation boards of type hard boards (PIR, PUR, XPS, Phenolic) produced according to the standard EN 13165 table 2 with tolerance classes T2 or T3.
07/2020
www.hilti.group
2
X-IE-H Fastener program Fastener selection table
Designation
X-IE-H 40 X-IE-H 50 X-IE-H 60 X-IE-H 75 X-IE-H 80
tI
Select Fastener with Designation equivalent to the insulation thickness tl
X-IE-H 100 X-IE-H 125 X-IE-H 150 X-IE-H 175
Fastener Item no. X-PH, Ls
Insulation thickness tl [mm]
X-PX 62 2207195 40 X-PX 62 2162046 50 X-PX 62 2162047 60 X-PX 62 2207196 75 X-PX 62 2162048 80
X-PX 62 2162049 100 X-PX 62 2207197 125 X-PX 62 2207198 150 X-PX 62 2207194 175
Note: the fastener length L is not equal to the insulation Exceptions: For intermediate thicknesses, thickness tl due to the intention of avoiding any countersunk effect of the fastener into the insulation board, L = tl + 6 mm. use the next longer X-IE-H. For convenience, pre-core the insulation boards before installation.
/V /
3
www.hilti.group
07/2020
X-IE-H System recommendation Tool DX 460 IE, DX 460 IE XL, DX 5 IE, DX 5 IE XL Cartridge selection and tool energy setting Cartridge recommendation: Steel:
6.8 / 11M yellow or red cartridge
Concrete 6.8 / 11M yellow or red cartridge Tool energy adjustment by setting tests on site. Application requirements Thickness of base material Concrete: Steel:
hmin = 80 mm tll ≥ 4 mm
Thickness of fastened material
Insulation thickness: tl = 40 – 175 mm Edge distances and minimum number of X-IE-H For minimum distances to insulation edges please inquire at the insulation material supplier. Please use minimum 4 pcs of X-IE-H fasteners per insulation plate and ≥ 5 pcs of X-IE-H fasteners per m2 Application limits Concrete: fcc = 15 – 45 N/mm2 (aggregate size ≤ 32 mm) Sand-lime masonry: fcc = 15 – 45 N/mm2 Clinker brick work: fcc = 28 – 45 N/mm2 Steel: fu = 360 – 540 N/mm2 (tll = 4 – 6 mm) Load data Recommended loads
N
Insulation thickness tI [mm]
Shear, Vrec [N]
Tension, Nrec [N]
V
07/2020
40 – 50 250
290
60
75 – 80
100 – 175
300
300
300
300
350
350
When base material properties are questionable, jobsite qualification is necessary.
www.hilti.group
4