X-IE DATA SHEET Insulation fastener
April 2021
X-IE
X-IE 6 and X-IE 9 insulation fasteners Product data X-IE 6
Product description • Suitable for a wide range of insulation materials – Soft mineral wool, mineral wool, EPS, XPS, PIR, PUR, soft core multilayer board, rigid core multilayer board • Suitable for 20–200 mm thick insulation • Very high thermal efficiency in a one-step solution • No holes in the fastener shank – helping prevent mold and moisture penetration in the insulation material • Gauge included for easy visual control of correct fastener driving depth • Specially-designed 90 mm disc diameter for soft mineral wool, providing excellent clamping of the insulation
X-IE 9
Dimensions
Ø
Designation X-IE 6 X-IE 9
Diameter Ø 60 mm 90 mm
Nail length L s 47–62 mm 47–62 mm
Color Colorless Black
Other properties UV stabilized material UV stabilized material
Ls
Material properties for plastic parts Element Plate Plate
04/2021
Designation X-IE 6 X-IE 9
Material HDPE HDPE
www.hilti.group
2
X-IE Material properties for carbon steel parts Element
Designation
Material
Coating
Hardness
Nail
X-PX 47, X-PX 52, X-PX 62
Minimum coating thickness
Carbon steel
Zinc
5 µm
58 HRC
Approvals and certificates Authority Socotec ITB ITB Russian Ministry / FCS
Approval / certificate no. 1601601R0000003 AT-15-7235 / 2015 AT-15-7696 / 2016 TS / TO 5851-19
Date of issue 07/ 2019 06/ 2016 12/ 2016 10/ 2019
Country of issue France Poland Poland Russia
ot all information presented in this product data sheet might be subject to approval / N certificate content. Please refer to approval / certificate for further information.
Applications Curtain wall insulation
Ceiling insulation
Basement perimeter insulation
Tough concrete
Solid brick
Base materials
Soft concrete
Medium concrete
Solid sandlime masonry
Steel
3 04/2021 www.hilti.group
X-IE Fastened materials
Soft mineral wool
Mineral wool
EPS
XPS
PIR, PUR
Soft and rigid core multilayer board
• Soft core multilayer board: hard top layer with insulation core of mineral wool • Rigid core multilayer board: hard top layer with insulation core of EPS, XPS, PIR, PUR Load condition
Static quasi-static
Environmental conditions
• The intended use comprises fastening in dry conditions. • During construction, exposure to UV due to solar radiation of the fixing element not protected by rendering shall not exceed the time of 6 weeks. • The temperature during installation of the fixing element shall not be less than 5 °C.
Application requirements Fastened material properties Fastened material
tI
04/2021
Compressive strength
Soft mineral wool < 500 kN / m2 Mineral wool < 500 kN / m2 EPS, XPS, PIR, PUR, soft core < 500 kN / m2 multilayer board Rigid core multilayer board
< 500 kN / m2
www.hilti.group
Fastened material thickness tl 50–200 mm 20–200 mm 20–200 mm 14–197 mm
4
X-IE Base material properties Base material Soft, medium concrete Tough concrete Solid sand-lime masonry Solid brick Steel
tII
Base material strength
Base material thickness tII
fcc = 15–45 N / mm2
≥ 80 mm
fcc = 45–65 N / mm2
≥ 80 mm
fb = 15–45 N / mm2
–
fb = 28–45 N / mm fu = 360–450 N / mm2
– 4–6 mm
2
Fastener edge distance and spacing in base material Minimum corner distance ce
Minimum edge distance c
100 mm
75 mm
Minimum fastener spacing distance s 100 mm
ce
s
c
ce
c
s
Fastener edge distance and spacing in insulation material Please consult insulation material supplier
Number of fasteners per m² Fastened material
Fastened material weight
Soft mineral wool, mineral wool, EPS, XPS, PIR, PUR, soft core multilayer board, rigid core multilayer board
≤ 15 kg/m² > 15 kg/m²
Fastened material
Fastened material density
Soft mineral wool, mineral wool, EPS, XPS, PIR, PUR, soft core multilayer board, rigid core multilayer board
≤ 75 kg/m3 > 75 kg/m3
Minimum number of fasteners per m² 4 5
Minimum number of fasteners per m² 4 5
5 04/2021 www.hilti.group
X-IE Performance data Recommended resistance under tension and shear load Base material
N
V
Soft, medium concrete Tough concrete Solid sand-lime masonry Solid brick Steel
Tension Nrec 0.4 kN 0.2 kN 0.2 kN 0.2 kN 0.6 kN
Shear Vrec 0.4 kN 0.2 kN 0.2 kN 0.2 kN 0.6 kN
• For more details in relation to base material properties, please refer to the chapter Fastener selection guide in the Direct Fastening Technology Manual (DFTM). • The above data value for solid sand-lime masonry and solid brick are based on laboratory and field experience. Because of the wide variety of types and forms of masonry in use worldwide, users are advised to carry out tests on site or on masonry of the type and form on which the fastenings are to be made. • The above data refers to the fastener pull-out failure mode. • For pull-over under tension load please consult insulation material supplier.
Stick rate estimation Designation
Soft, medium concrete Tough concrete 15 ≤ fc,cube ≤ 45 N / mm2 45 < fc,cube ≤ 65 N / mm2 X-IE 6, X-IE 9 90 %–95 % 85 %–90 % he stick rate indicates the percentage of nails that were driven correctly to carry T a load. Stick rate can vary from the above values depending on job site conditions Thermal efficiency according to EOTA TR 025 Application Curtain wall insulation Ceiling insulation Basement perimeter insulation 04/2021
Insulation thickness tI 60–90 mm 100–200 mm 60–90 mm 100–200 mm 60 mm 70–100 mm 120–200 mm www.hilti.group
Point thermal transmittance ϰ 0.002 W/K 0.001 W/K 0.002 W/K 0.001 W/K 0.003 W/K 0.002 W/K 0.001 W/K 6
X-IE System recommendation
• For more details, please refer to the chapter Accessories and consumables compatibility in the Direct Fastening Technology Manual (DFTM).
Tool and energy recommendation Designation
Tools and equipment DX 6 IE
L equipment Fastener guide: X-6-FIE-L Piston: X-6-5-PIE-L
X-IE 6 X-IE 9
X-IE 6-20
L equipment Fastener guide: X-5-460-FIE-L Piston: X-5-460-PIE-L
XL equipment Fastener guide: X-5-460-FIE-XL Piston: X-5-460-PIE-XL
DX 460 IE L equipment Fastener guide: X-5-460-FIE-L Piston: X-5-460-PIE-XL
XL equipment Fastener guide: X-5-460-FIE-XL Piston: X-5-460-PIE-XL
X-IE 6-140
■
■
■
■
■
■
X-IE 9-140
■
■
■
■
■
■
X-IE 6-150
X-IE 6-200
X-IE 9-160
X-IE 9-200
X-IE 9-50
DX 5 IE
XL equipment Fastener guide: X-6-FIE-XL Piston: X-6-5-PIE-XL
■ ■
■ ■
■ ■
■ = recommended, ■ = feasible Cartridge recommendation Base material
Soft, medium concrete Tough concrete Solid sand-lime masonry Solid brick Steel
Cartridge color (tool power level) Tool type: Tool type: DX 6 IE DX 5 IE, DX 460 IE Cartridge type: 6.8/11 M Cartridge type: 6.8/11 M titanium ■ (2–8) yellow ■, red ■ titanium ■ (2–8) yellow ■, red ■ titanium ■ (1–5) green ■, yellow ■ titanium ■ (1–5) green ■, yellow ■ titanium ■ (2–8) yellow ■, red ■
• Tool power level adjustment by setting tests on site. • Start tool energy selection with lowest recommended tool power level. • Correct according requirement from chapter quality assurance.
7 04/2021 www.hilti.group
X-IE Fastener selection Fastened material
Soft mineral wool
Fastened material
Mineral wool, EPS, XPS, PIR, PUR, soft core multilayer board
04/2021
Insulation thickness tI 50 mm 60 mm 80 mm 90 mm 100 mm 120 mm 140 mm 160 mm 180 mm 200 mm Insulation thickness tI 20 mm 25 mm 30 mm 35 mm 40 mm 50 mm 60 mm 70 mm 75 mm 80 mm 90 mm 100 mm 120 mm 125 mm 140 mm 150 mm 160 mm 175 mm 180 mm 200 mm
Designation
Nail
Item number
X-IE 9-50 X-IE 9-60 X-IE 9-80 X-IE 9-90 X-IE 9-100 X-IE 9-120 X-IE 9-140 X-IE 9-160 X-IE 9-180 X-IE 9-200
X-PX 62 X-PX 62 X-PX 62 X-PX 62 X-PX 62 X-PX 62 X-PX 62 X-PX 62 X-PX 62 X-PX 62
2092034 2041746 2041747 2041748 2041749 2041750 2041751 2041752 2041753 2041754
Designation
Nail
Item number
X-IE 6-20 X-IE 6-25 X-IE 6-30 X-IE 6-35 X-IE 6-40 X-IE 6-50 X-IE 6-60 X-IE 6-70 X-IE 6-75 X-IE 6-80 X-IE 6-90 X-IE 6-100 X-IE 6-120 X-IE 6-125 X-IE 6-140 X-IE 6-150 X-IE 6-160 X-IE 6-175 X-IE 6-180 X-IE 6-200
X-PX 47 X-PX 47 X-PX 52 X-PX 52 X-PX 52 X-PX 62 X-PX 62 X-PX 62 X-PX 62 X-PX 62 X-PX 62 X-PX 62 X-PX 62 X-PX 62 X-PX 62 X-PX 62 X-PX 62 X-PX 62 X-PX 62 X-PX 62
2143956 2041714 2041715 2041716 2041717 2041718 2041719 2041740 2041741 2041742 2041743 2041744 2041745 2323244 2041393 2048523 2041394 2323245 2041395 2041396
www.hilti.group
8
X-IE
Fastened material
Rigid core multilayer board
Insulation thickness tI 14–17 mm 19–22 mm 24–27 mm 29–32 mm 34–37 mm 44–47 mm 57–57 mm 64–67 mm 69–72 mm 74–77 mm 84–87 mm 94–97 mm 114–117 mm 119–122 mm 134–137 mm 144–147 mm 154–157 mm 169–172 mm 174–177 mm 194–197 mm
Designation
Nail
Item number
X-IE 6-20 X-IE 6-25 X-IE 6-30 X-IE 6-35 X-IE 6-40 X-IE 6-50 X-IE 6-60 X-IE 6-70 X-IE 6-75 X-IE 6-80 X-IE 6-90 X-IE 6-100 X-IE 6-120 X-IE 6-125 X-IE 6-140 X-IE 6-150 X-IE 6-160 X-IE 6-175 X-IE 6-180 X-IE 6-200
X-PX 47 X-PX 47 X-PX 52 X-PX 52 X-PX 52 X-PX 62 X-PX 62 X-PX 62 X-PX 62 X-PX 62 X-PX 62 X-PX 62 X-PX 62 X-PX 62 X-PX 62 X-PX 62 X-PX 62 X-PX 62 X-PX 62 X-PX 62
2143956 2141714 2141715 2141716 2141717 2141718 2141719 2141740 2141741 2141742 2141743 2141744 2141745 2323244 2041393 2048523 2041394 2323245 2041395 2041396
• Insulation board thickness tolerance: ±3 mm • Soft mineral wool, mineral wool: for intermediate thicknesses use next shorter fastener, example: for mineral wool insulation thickness 110 mm, use X-IE 6-100 • EPS, XPS, PIR, PUR, soft core multilayer board: for intermediate thicknesses use next longer fastener, example: for PIR insulation thickness 110 mm, use X-IE 6-120 • Rigid core multilayer board: for thicknesses not specified, please contact Hilti
9 04/2021 www.hilti.group
X-IE Quality assurance Fastening inspection
hET
x
tI
04/2021
Designation
X-IE 6-20 X-IE 6-25 X-IE 6-30 X-IE 6-35 X-IE 6-40 X-IE 6-50, X-IE 9-50 X-IE 6-60, X-IE 9-60 X-IE 6-70 X-IE 6-75 X-IE 6-80, X-IE 9-80 X-IE 6-90, X-IE 9-90 X-IE 6-100, X-IE 9-100 X-IE 6-120, X-IE 9-120 X-IE 6-125 X-IE 6-140, X-IE 9-140 X-IE 6-150 X-IE 6-160, X-IE 9-160 X-IE 6-175 X-IE 6-180, X-IE 9-180 X-IE 6-200, X-IE 9-200
www.hilti.group
Embedment depth
hET 24 – 29 mm 24 – 29 mm 24 – 29 mm 24 – 29 mm 24 – 29 mm 24 – 29 mm 24 – 29 mm 24 – 29 mm 24 – 29 mm 24 – 29 mm 24 – 29 mm 24 – 29 mm 24 – 29 mm 24 – 29 mm 24 – 29 mm 24 – 29 mm 24 – 29 mm 24 – 29 mm 24 – 29 mm 24 – 29 mm
Distance between nail head and X-IE plate x 4 – 9 mm 4 – 9 mm 4 – 9 mm 4 – 9 mm 9 – 14 mm 9 – 14 mm 19 – 24 mm 29 – 34 mm 34 – 39 mm 39 – 44 mm 49 – 54 mm 59 – 64 mm 79 – 84 mm 84 – 89 mm 99 – 104 mm 109 – 114 mm 119 – 124 mm 134 – 139 mm 139 – 144 mm 159 – 164 mm
10
X-IE Setting depth control and power tool adjustment Check setting depth with the gauge immediately after fastening
Adjust the power setting if required
• Visible setting failures must be replaced with a new fastener, not in the same hole • These are abbreviated instructions which may vary by application. • ALWAYS review / follow the instructions accompanying the product
11 04/2021 www.hilti.group