ISSUE 0110
7x5 OLAP SINGLE DOOR PENT SHED ASSEMBLY INSTRUCTIONS
IMPORTANT : ASSEMBLY OF THIS SHED REQUIRES TWO PEOPLE
SHOULD YOU REQUIRE ANY ADDITIONAL GUIDANCE WITH THE ASSEMBLY OF YOUR SHED PLEASE CONTACT OUR TECHNICAL HELP LINE ON 0844 248 9853
IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY Thank you for choosing this garden building manufactured by the UK's largest manufacturer of timber garden products. In order to gain the most benefit from it, please note the following: - Exercise particular care and follow instructions whilst cutting the roofing felt. If it is cut incorrectly, additional roofing felt can be inexpensively purchased from most good DIY retailers or garden centres. - This buildings is pre-treated to ensure longevity of all timber components and to protect against rot. This may leave a colour difference on some parts that will even out as the moisture content stabilises. - If there are any technical queries with the product, please contact our customer help line on 0844 248 9853 between the hours of 8.30 am and 5.00 pm Monday to Friday. - Please ensure that you thoroughly check all component parts for quantity and quality before you commence building the product. If there are any missing parts, please contact the help line as shown immediately. The manufacturer cannot be held liable for damaged items once any part of the product has been fitted or altered in any way (e.g. Painted) - Timber is a natural material. It will shrink and swell as a result of varying moisture content. - Please keep all plastic bags and small parts away from children in order to reduce the risk of suffocation. -This product must be built on a flat level base.
FIXING PACK CONTENTS :Fp05
REQUIRED TOOLS : (NOT SUPPLIED)
23
PLEASE NOTE: ALL SCREWS
M6x30mm SCREW
DRILL
AND NAILS SHOWN BELOW AND IN INSTRUCTIONS ARE TO SCALE TO ASSIST IN IDENTIFICATION OF REQUIRED FIXINGS.
POZI DRIVE SCREWDRIVER SHARP KNIFE TO CUT ROOF FELT
M8x50mm SCREW
SPIRIT LEVEL
22
T-HINGE x 2
64 TAPE MEASURE
30mm NAIL
FELT NAIL HAMMER
PANEL PIN
71
Z BRACKET x2
HASP AND STAPLE SET
24
543354FRV2PTR 543354BKV2PTR
(FRONT)
(BACK)
PW610520 QTY 2 (STYRENE WINDOW)
ADD75FL QTY 1 (OSB FLOOR)
PTGVDR1672PTR QTY 1 (DOORS)
FIXING PACK Fp05 x 1 85009 QTY 2 (PVC TRIM 30x12x610mm )
543354LHSV2PTR
207016508
(LEFT HAND SIDE)
(OSB ROOF SHEET 2070x1650x8) 543354RHSV2PTR (RIGHT HAND SIDE)
61081650PTR QTY 2 (BARGE BOARD 61x8x1650mm PTR)
60150500PTR QTY 3 (WINDOW COVER STRIP 60x15x500mm PTR)
45151690PTR QTY 2 (CORNER STRIP 45x15x1690mm PTR) 28281982PTR QTY 1 (BATTEN 28x28x1982mm) 28282070PTR QTY 2 (BATTEN 28x28x2070mm)
45152000PTR QTY 2 (CORNER STRIP 45x15x2000mm PTR) 15120585PTR QTY 6 (GLAZING STRIP 15x12x585 PTREAT)
1
FELT x 1
85025
X 14 7 PER HINGE
FASTEN EACH OF THE TWO HINGES TO THE LEFT HAND SIDE OF PTGVDR1672PTR (DOOR) USING 4 x 30mm SCREWS (THE SCREWS MUST SECURE INTO THE TWO HORIZONTAL BRACES ON THE REVERSE SIDE OF THE DOOR). LAY 543354FRV2PTR (FRONT) FACE UP ON THE GROUND. POSITION PTGVDR1672PTR (DOOR) INTO THE DOOR RECESS OF 543354FRV2PTR (FRONT). ENSURE THAT THE DOOR IS POSITIONED SO THAT IT IS SQUARE AND HAS AN EQUAL GAP TO THE LEFT AND RIGHT. ONCE POSITIONED, SECURE THE HINGES IN PLACE WITH 2x30mm SCREWS FOR EACH.
30mm
543354FRV2PTR
PTGVDR1672PTR
Forest Garden Ltd, Units 291 & 296 Hartlebury Trading Estate, Hartlebury, Worcestershire, Dy10 4JB
ISSUE 0110
2
X3 50mm
L NE PA E D SI
543354BKV2PTR
BA CK
PA NE L
POSITION 543354BKV2PTR (BACK PANEL) OF THE SHED ONTO THE ADD75FL (FLOOR) SO THAT THE PANEL SITS ON THE LIP OF ADD75FL(FLOOR) AND BOTH THE RIGHT AND LEFT HAND EDGES ARE FLUSH. PLACE 543354LHSV2PTR (LEFT SIDE PANEL) ONTO ADD75FL (FLOOR) AND PLACE UP AGAINST 543354BKV2PTR (BACK PANEL). SECURE THROUGH 543354LHSV2PTR (LEFT SIDE PANEL) INTO 543354BKV2PTR (BACK PANEL) USING 3 x 50mm SCREWS,
543354LHSV2PTR
ADD75FL
PLACED AS SHOWN. DO NOT SECURE THE PANELS TO THE FLOOR AT THIS POINT
3
X9
4
X 10
50mm
50mm
50mm
50mm
50mm 50mm 50mm
50mm 543354FRV2PTR
50mm
50mm 543354RHSV2PTR
50mm
USING THE PROCEDURE SHOWN IN STEP 2, POSITION THE REMAINING 543354RHSV2PTR (RIGHT SIDE PANEL) AND
543354FRV2PTR (FRONT PANEL) .
ONCE ALL FOUR PANELS ARE IN PLACE AND FASTENED TOGETHER, SECURE THEM TO ADD75FL (FLOOR) USING 50mm SCREWS. EACH SIDE PANEL WILL NEED 2 x 50mm SCREWS AND 3x50mm SCREWS FOR EACH OF THE 543354FRV2PTR (FRONT) AND 543354BKV2PTR ( BACK). IT IS VITAL THAT ALL SCREWS ARE POSITIONED THAT THEY LOCATE INTO THE FLOOR BEARERS
5
PLACE 207016508 (OSB ROOF SHEET) ON TOP OF 2 X 28282070PTR (BATTENS 28x28x2070mm). EACH BATTEN MUST BE PLACED FLUSH WITH THE OUTER EDGES OF 207016508 (OSB ROOF), SECURE IN PLACE THROUGH 207016508 (OSB ROOF SHEET) INTO 28282070PTR (BATTEN 28x28x2070mm) WITH 8x30mm NAILS PER BATTEN
X16
207016508
28282070PTR
ISSUE 0110
6
X4
‘Z’BRACKET
28281982PTR SECURE A ‘Z’ BRACKET TO EITHER END OF A 28281982PTR (BATTEN 28x28x1982mm) WITH A 30mm SCREW. PLACE 28281982PTR (BATTEN 28x28x1982mm) WITH BOTH THE ‘Z’ BRACKETS ATTACHED, BETWEEN THE SIDE OF THE SHED SO THAT THE ‘Z’ BRACKETS SIT ONTO THE SIDE SECTION FRAMEWORK. PLACE THIS APPROXIMATELY HALF WAY BETWEEN THE FRONT AND BACK OF THE SHED AND THEN SECURE IN PLACE BY USING 2x30mm SCREWS TO FIX THE ‘Z’ BRACKETS IN PLACE
28281982PTR
7 X26
PLACE THE ASSEMBLED 207016508 (ROOF) SECTION ON TOP OF THE SHED. WHEN IN PLACE, THE 207016508 (ROOF) SECTION SHOULD OVERHANG BY EQUAL AMOUNTS AT ALL SIDES OF THE SHED. SECURE 207016508 (ROOF) SECTION IN PLACE WITH 30mm NAILS PLACED AT 300mm INTERVALS INTO THE SHED FRAMEWORK.
8
ROOF
FELT S HEET 2 ROOF
FELT S
HEET 1
FELT NAIL PLACED AT 150mm INTERVALS
OPEN ROOFING FELT AND ROLL OUT FLAT ON GROUND WHEN FELT HAS FLATTENED CUT IT INTO TWO EQUAL LENGTHS. PLACE THE FIRST PIECE OF FELT SO THAT IT OVERLAPS EQUAL AMOUNTS AT BOTH THE LEFT AND RIGHT SIDE OF THE SHED, AND APPROXIMATELY 40mm AT THE BACK OF THE ROOF. SECURE THE FELT WITH FELT NAILS PLACED AT 150mm INTERVALS ALONG THE OUTER EDGES OF THE ROOF. CUT AND FOLD FELT AT CORNERS AND SECURE THE FOLD WITH A FELT NAIL. REPEAT THE PROCESS WITH SECOND PIECE OF FELT SO THAT IT OVERLAPS THE FIRST, AS SHOWN ON DRAWING, PLACE ANOTHER LINE OF FELT NAILS AT 150mm INTERVALS WHERE THE TWO PIECES OVERLAP.
ISSUE 0110
9
10 X 4 PER BARGE BOARD
X 3 PER CORNER STRIP
SECURE BOTH 45151690PTR (CORNER STRIPS) WITH 3 x 30mm NAILS PER STRIP. PLACE THE 45151690PTR (CORNER STRIP) IN THE GAP BETWEEN THE CLADDING MAKING SURE THAT THE BOTTOM OF THE 45151690PTR (CORNER STRIP) IS FLUSH WITH THE CLADDING OF BOTH PANELS. REPEAT THIS PROCESS WITH THE LARGER 45152000PTR (CORNER STRIPS)
45152000PTR
61081650PTR
POSITION 61081650PTR (BARGE BOARD) ON THE LEFT AND RIGHT HAND OF THE SHED SO THAT THE TOP EDGE OF THE BOARD IS IN LINE WITH THE TOP EDGE OF THE ROOF. SECURE EACH 61081650PTR (BARGE BOARD) IN PLACE WITH 4 x 30mm NAILS, PLACED AS SHOWN. TRIM OFF ANY EXCESS FELT THAT IS SHOWING BELOW THE BOARDS.
45151690PTR
11b
11a X3 PER WINDOW COVER STRP I
X3 FOR PLASTIC “Z” STRIP x3 FOR EACH GLAZING STRIP
15120585PTR
OF OR RI E T IN E EN YR T S
15120585PTR ON EXTERIOR OF SHED
PLASTIC Z STRIP x 1 ON EXTERIOR OF SHED
60150500PTR
Pw610520
ATTACH EACH OF THE THREE 60150500PTR (WINDOW COVER STRIPS) TO THE OUTSIDE OF THE SHED WITH 3 x 30mm NAILS. THE CENTRAL 60150500PTR (COVER STRIP) SHOULD HAVE AN EQUAL OVER HANG ON BOTH THE LEFT AND RIGHT SIDE OF THE CENTRAL WINDOW BATTEN. THE OTHER TWO 60150500PTR ( COVER STRIPS) SHOULD BE PLACED FLUSH WIT THE OUTER EDGES OF THE CLADDING.
12 STAPLE X6 3 FOR HASP 2 FOR STAPLE
30mm
SECURE THE HASP TO THE OUTSIDE OF THE DOOR USING 3x30mm SCREWS. THE SCREWS MUST LOCATE INTO THE SHORT BATTEN ON THE INSIDE OF THE DOOR. SECURE THE STAPLE TO THE DOOR END OF THE SHED USING 2x30mm SCREWS.
HASP
DOOR OR DO
D EN
PLACE PLASTIC ‘Z’ STRIP ACROSS THE BOTTOM OF EACH WINDOW OPENING. THE LONG FACE OF THE Z SHOULD BE ON THE OUT SIDE OF THE SHED. SECURE IN PLACE WITH 3 PANEL PINS. PLACE Pw610520 (PVC WINDOW) INTO THE WINDOW OPENING FROM INSIDE OF THE SHED. THE BOTTOM OF THE Pw610520 (WINDOW) SHOULD SIT ON TOP OF THE PLASTIC ‘Z’ STRIP. PLACE A 15120585PTR (GLAZING STRIP) ALONG THE BOTTOM OF THE WINDOW FRAME ON THE OUTSIDE OF THE SHED AND SECURE IN PLACE USING 3x30mm PANEL PINS. PLACE 15120585PTR (GLAZING STRIPS) TO THE LEFT AND RIGHT OF THE WINDOW FROM INSIDE AND SECURE USING 3x30mm PANEL PINS FOR EACH. REPEAT THIS PROCEDURE FOR BOTH WINDOWS