4

Ultrasonic scaling at a precise and steady vibration prevents damage of the natural tooth structure. Ten versions of NSK Varios tips allow the removal of supragingival calculus, interdental calculus, and calculus at the tooth neck.

5


TipBook_p01-17_e.qxd

06.1.22

4:08 PM

Page 6

SCALING

G1

G4

To remove calculus on anterior teeth, the neck of molars, and supragingival calculus, the side of the Varios tip should be placed on the tooth and moved sideways.

Removal of subgingival and interdental calculus from anterior and molar teeth. To remove calculus from anterior teeth, place the top of the tip on the neck of the tooth and move it along the tooth plane.

NSK Satelec®

MODEL

ORDER CODE

G1

Z217-101

G1-E

Z291-101

NSK Satelec®

7.2 EMS®

23.3

8.1

ORDER CODE

G4

Z217-104

G4-E

Z291-104

23.0

G2

G5

To remove heavy calculus place the top of the G2 flat tip against the tooth plane and activitate the ultrasonic scaler.

To remove interdental calculus and calculus in pockets, insert the tip between the teeth while touching the tip on the tooth.

NSK Satelec®

G2

Z217-102

G2-E

Z291-102

11.2

7.0 EMS®

23.4

NSK Satelec®

20.1

G5

Z217-105

G3

G6

To remove heavy nicotine stains, place the top and the side of the tip on the tooth plane and gently move the tip up and down.

Insert the tip between teeth and remove calculus while keeping the top of the tip on the tooth plane to remove tartar.

NSK Satelec®

G3

NSK

Z217-103

Satelec®

11.1

G6

Z217-106

G6-E

Z291-106

11.4 EMS®

20.0

6

EMS®

MODEL

G3-E

Z291-103

Satelec® is registered trademarks of Acteon SA, France. EMS® is registered trademarks of Electro Medical Systems SA, Switzerland.

EMS®

23.2

Refer to the power setting chart on pages 44-45.

7


TipBook_p01-17_e.qxd

06.1.22

4:09 PM

Page 8

SCALING

G7

G13

Removal of interdental heavy calculus.

Sickle type. It is suitable for removing calculus of the neck and interdental calculus.

MODEL

ORDER CODE

8.8 NSK Satelec®

23.3

6.7

G7

Z217-107

G11

Z217-411

G12

Z217-412

22.2

NSK Satelec®

MODEL

ORDER CODE

G13

Z217-413

G11 Universal type. Removal of calculus from a wide plane such as anterior teeth.

6.9

NSK Satelec®

23.1

G12 Perio type. The tip with the sharp angle removes calculus of the molar.

7.4 22.9

8

NSK Satelec®

Satelec® is registered trademarks of Acteon SA, France.

Refer to the power setting chart on pages 44-45.

9


TipBook_p01-17_e.qxd

06.1.22

4:09 PM

PERIO

10

Page 10

Varios tips, angled from right and left, plus straight, are available to provide the best approach to furcation and curved root faces.

11


TipBook_p01-17_e.qxd

06.1.22

4:10 PM

PERIO

Page 12

P2D / P3D (From above)

(ROOT PLANING)

P2D Right curved tip

P3D Left curved tip

P1

P2D

Ultra thin tips provide easy access to anterior teeth, narrow pockets and complex crowded teeth.

Diamond coated tip effectively removes persistent subgingival calculus. Right curved tip.

• Diamond coated

MODEL

ORDER CODE

6.9 NSK Satelec®

27.0

7.4

P1

NSK

Z217-404

Satelec®

27.0

P1D

P3D

P1D is diamond coated tip and its shape is the same as P1 tip. Designed for the removal of fine calculus and for the finishing of root planing.

Left curved tip.

• Diamond coated

MODEL

ORDER CODE

P2D

Z217-402

• Diamond coated

6.9 NSK Satelec®

27.0

P1D

7.4

Z217-405 27.0

P10

NSK Satelec®

P3D

Z217-403

Perio Kit A

Y900-144

Perio Kit A

To remove subgingival stains, the tip may be used as per manual curettes.

NSK

• Sharp edge

Satelec®

• P1D, P2D, P3D, P10 : 1 pc. each • Tip holder : 1 pc. 6.8 31.6

12

NSK Satelec®

P10

Z217-410

Satelec® is registered trademarks of Acteon SA, France.

Refer to the power setting chart on pages 44-45.

13


TipBook_p01-17_e.qxd

06.1.22

4:10 PM

PERIO

Page 14

P21R / P20 / P21L / P25R / P25L (From above)

(ROOT PLANING)

P21R Right curved tip P25R Right curved tip P20

Straight tip P25L Left curved tip

P21L Left curved tip

P20

P25R

Straight tip.

For root planning of molar furcation and complicated curve. Right curved tip.

NSK

12.3

Satelec®

MODEL

ORDER CODE

P20

Z217-420

NSK Satelec®

MODEL

ORDER CODE

P25R

Z217-424

P25R-E

Z291-424

P25L

Z217-425

P25L-E

Z291-425

Perio Kit B

Y900-145

7.6 EMS®

28.5

P20-E

Z291-420

EMS®

27.2

P21R

P25L

Right curved tip.

Left curved tip.

NSK Satelec®

P21R

Z217-422

P21R-E

Z291-422

NSK Satelec®

11.4

7.6 EMS®

27.7

EMS®

27.2

P21L

Perio Kit B

Left curved tip.

NSK Satelec® NSK Satelec®

P21L

Z217-421

P21L-E

Z291-421

• P20, P25R, P25L : 1 pc. each • Tip holder : 1 pc.

11.4 EMS®

27.7

14

Satelec® is registered trademarks of Acteon SA, France. EMS® is registered trademarks of Electro Medical Systems SA, Switzerland.

Refer to the power setting chart on pages 44-45.

15


TipBook_p01-17_e.qxd

06.1.22

4:11 PM

PERIO

Page 16

MAINTENANCE

(Irrigating and Cleaning) For effective cleaning following debridement or scaling.

( V-T ip )

For the maintenance of prostheses and implants. Produced from special material to allow safe debridement without causing damage to metals and implants.

P40

V10

NSK

3

MODEL

ORDER CODE

Satelec®

14.7

6

NSK Satelec®

P40

17.8

Z217-550

MODEL

ORDER CODE

V10

Z217-041

* Plastic Tip is not included

28.9

• Tip diameter ø 0.6 mm

ø 0.6

P41

V- P 1 0

7.9

• Pack of 3

V-P10

Y900-184

3

14.8

6

14.4 NSK Satelec®

28.9

ø 0.8

P41

Z217-555

• Tip diameter ø 0.8 mm

Dual irrigation points • Irrigation from dual points on lateral areas of the apex. • Effective cleaning regardless of the insertion angle. • Safe to use regardless of the pocket condition due to the marking guideline of 3 mm from the position of 6 mm. • The rounded apex shape for safety in periodontium.

16

Satelec® is registered trademarks of Acteon SA, France.

Refer to the power setting chart on pages 44-45.

17


TipBook_p18-49_e.qxd

06.1.22

3:45 PM

Page 18

ENDODONTICS

18

NSK offers endodontic tips to achieve quick and effective treatments for root canal enlarging, irrigation, and filling. File and diamond tips for root canal enlarging, tips for root canal irrigation, tips for gutta-percha filling, tips for removal of materials and foreign bodies in root canal.

19


TipBook_p18-49_e.qxd

06.1.22

3:46 PM

Page 20

ENDODONTICS

E4

E4D

Application for root canal cleaning and removal of foreign particles.

Application for root canal cleaning and root canal enlargement. • Diamond coated

.6 NSK Satelec®

23.2

ORDER CODE

1.0

15.8 .0

MODEL

10

14

15.8

14

.6

* In order to reduce the incidence of ledge formation, no diamond coating is attached from the end up to 1mm of the tip. E4

Z217-428

with diamond

NSK Satelec®

23.2

E7

E7D

Removal of filling and foreign material.

Enlargement of root canal wall. • Water not required

.0 13

Z217-307

with diamond NSK Satelec®

24.1

E8D

Removal of filling and foreign material.

Enlargement of root canal wall. • Water not required

E7D

Z217-317

• Diamond coated

29.6

E8

Z217-308

NSK

23 .0

NSK

26

.0

29.6

26 .0

Z217-528

20.6

.0

E7

E8

Satelec®

with diamond

Satelec®

E8D

Z217-318

28.4

28.4

20

E4D

16

.0 16

NSK Satelec®

8

ORDER CODE

• Diamond coated

20.6

24.1

MODEL

Satelec® is registered trademarks of Acteon SA, France.

Refer to the power setting chart on pages 44-45.

21


TipBook_p18-49_e.qxd

06.1.22

3:46 PM

Page 22

ENDODONTICS

E5

E11

Lateral condensation.

120˚ Angle Holder for U files

• • • •

For U files (Shank dia : 0.8 mm) For root canal cleaning For anterior teeth Includes E Tip replacement wrench * File is optional

• Water not required

12.8

0

NSK

17.

NSK Satelec®

21.5

Satelec®

15.2

21.5 MODEL

ORDER CODE

E5

Z217-305

MODEL

ORDER CODE

E11

Z217-031

E12 • • • •

For U files (Shank dia : 0.8 mm) For root canal cleaning For posterior teeth Includes E Tip replacement wrench File is optional *

95˚ Angle Holder for U files

95

16.2

E6

NSK

Lateral condensation.

Satelec®

12.6

E12

Z217-032

• Water not required

20 .0

U files Length : 33 mm Shank dia. : 0.8 mm

21.3 NSK

24.3

Satelec®

E6

Z217-306

• ISO15 • Pack of 6

• ISO20 • Pack of 6

• ISO25 • Pack of 6

• ISO30 • Pack of 6

U files 33 mm / #15

Y900-062

U files 33 mm / #20

Y900-063

U files 33 mm / #25

Y900-064

U files 33 mm / #30

Y900-065

U files 33 mm / #35

Y900-066

• ISO35 • Pack of 6

Endo Kit E11

Endo Kit E12

for anterior teeth

for posterior teeth

NSK Satelec®

Endo Kit E11

Y900-146

• E11 : 1 pc. • E Tip replacement wrench : 1 pc. • U files 33 mm #15, #20, #25, #30, #35 : Pack of 6 each size

22

Satelec® is registered trademarks of Acteon SA, France.

NSK Satelec®

Endo Kit E12

Y900-147

• E12 : 1 pc. • E Tip replacement wrench : 1 pc. • U files 33 mm #15, #20, #25, #30, #35 : Pack of 6 each size

Refer to the power setting chart on pages 44-45.

23


TipBook_p18-49_e.qxd

06.1.22

3:46 PM

Page 24

ENDODONTICS

( V-Tip )

V30

V30

MODEL

8.3

NSK Satelec®

29.5

V30

ORDER CODE

8.3

Z217-030 29.5

V- S 5 1

V- S 5 2

V- S 5 3 • For root canal cleaning 32 mm • Pack of 3

Y900-169

9.1 with diamond

• Diamond coated • For root canal enlargement 17 mm • Pack of 3

V-S51

Y900-170

ø1.5

V-S52

Y900-171

ø1.5

V-S53

Y900-172

Y900-173

ø1.5

V-S51D

Y900-174

ø1.5

V-S52D

Y900-175

ø1.5

V-S53D

Y900-176

18.2

19.0 with diamond

• Diamond coated • For root canal enlargement 26 mm • Pack of 3

21.2

V- S 5 3 D

27.2

V-S50D

16.0 with diamond

• Diamond coated • For root canal enlargement 23 mm • Pack of 3

V- S 5 2 D

21.2

ø1.5 12.6

V- S 5 1 D ø1.5

• For root canal cleaning 26 mm • Pack of 3

• Includes E Tip replacement wrench

V- S 5 0 D V-S50

18.2

• For root canal cleaning 23 mm • Pack of 3

Z217-030

For Root Canal Enlargement

12.6 ø1.5

V30

NSK

* Tip is optional

For Root Canal Cleaning V- S 5 0

ORDER CODE

Satelec®

• Includes E Tip replacement wrench * Tip is optional

• For root canal cleaning 17 mm • Pack of 3

MODEL

25.0 with diamond

• Diamond coated • For root canal enlargement 32 mm • Pack of 3

27.2

1.0

order to reduce the incidence of * Inledge formation, no diamond coating is attached from the end up to 1mm of the tip.

24

Satelec® is registered trademarks of Acteon SA, France.

Refer to the power setting chart on pages 44-45.

25


TipBook_p18-49_e.qxd

06.1.22

3:47 PM

Page 26

RETROGRADE ENDO The microscopic diamond coated tip allows effective removal of dentin at the apex. 2 types of angled tips (90°, 70°) are available for anterior teeth and another 2 types of curved tips (right and left) are available for molar.

E30RD

E31D

Diamond coated tip allows efficient cavity preparation.

Diamond coated tip allows efficient cavity preparation.

• Diamond coated • For posterior teeth (right angled) 12.2

MODEL

NSK Satelec®

20.2

E30RD

• Diamond coated • For anterior and posterior teeth (70˚)

ORDER CODE

12.5 NSK

Z217-212

Satelec®

17.8

E30LD

E32D

Diamond coated tip allows efficient cavity preparation.

Diamond coated tip allows efficient cavity preparation.

ORDER CODE

E31D

Z217-210

• Diamond coated • For anterior teeth (90˚)

• Diamond coated • For posterior teeth (left angled)

13.4

12.2 NSK

20.2

MODEL

Satelec®

NSK

E30LD

Z217-213

18.9

Satelec®

E32D

Z217-211

Retro Kit

Y900-149

R e t ro K i t

NSK Satelec®

• E30RD, E30LD, E31D, E32D : 1 pc. each • Tip holder : 1 pc.

26

Satelec® is registered trademarks of Acteon SA, France.

Refer to the power setting chart on pages 44-45.

27


TipBook_p18-49_e.qxd

06.1.22

3:47 PM

Page 28

RESTORATIVE

28

Ultrasonic vibration is applied to the tooth surface. The compact handpiece is ideal for small mouths and at sites where a rotary handpiece is difficult to access. A variety of tips are available for caries removal and tooth surface characterization.

29


TipBook_p18-49_e.qxd

06.1.22

3:47 PM

Page 30

R E S T O R AT I V E

( V- T i p )

For Minimal Intervention The NSK Varios V-Tip System has been developed to meet “Minimal Intervention” dental procedures. As a variation to rotary cutting, the Varios V-Tip offers precise and effective ultrasonic technology cutting. The advantage of ultrasonic cutting decay removal is that tip movement is minute allowing only decayed dentine to be removed, while sound dentine is preserved.

V30

V30

MODEL

8.3

NSK Satelec®

29.5

V- G 7 0 • Diamond coated • Pack of 3

• Diamond coated • Pack of 3

V- G 7 5 ø1.5

V-G70

Y900-118

ø1.5

V-G71

Y900-119

ø1.5

V-G72

Y900-120

1.0

• Diamond coated • Pack of 3

1.5

ORDER CODE

V30

Z217-030

• Includes E Tip replacement wrench * Tip is optional

12.0

0.6

0.9

MODEL

ø1.5

V-G75

Y900-121

ø1.5

V-G76

Y900-122

Assorted Tip Kit

Y900-158

12.3

12.8 ø 1.6

MI Starter Kit

Assorted Tip Kit

NSK Satelec®

MI Starter Kit

Y900-150

• V30 V-tip holder : 1 pc • E Tip replacement wrench : 1 pc • V-G70, V-G71, V-G72, V-S1, V-S3, V-S33 V-G77, V-G78, V-G79 : 1 pc. each

30

• Diamond coated • Pack of 3

V- G 7 6

12.5 ø 1.2

NSK Satelec®

29.5

• Includes E Tip replacement wrench * Tip is optional

ø 0.8

V- G 7 2

8.3

Z217-030

12.5

V- G 7 1 • Diamond coated • Pack of 3

V30

ORDER CODE

Satelec® is registered trademarks of Acteon SA, France.

• V-G70, V-G71, V-G72, V-G75, V-G76 : 1 pc. each

Refer to the power setting chart on pages 44-45.

31


TipBook_p18-49_e.qxd

06.1.22

3:47 PM

Page 32

R E S T O R AT I V E

R E S T O R AT I V E

( V- T i p )

F o r F i n i s h i n g / Tr i m m i n g / P o l i s h i n g

For Caries of Dentin

Three grades of diamond particles are available – Normal, Fine and Super Fine – for tooth surface characterization to polishing.

V-S1, V-S3 and V-S33 are very effective in minimal intervention cavity preparation. 3 types of tips are available in response to cavity preparation requirements.

V30

V30 MODEL

8.3

NSK Satelec®

29.5

V- G 7 7

4.5

• Diamond coated • Pack of 3

Y900-165

4.5

ORDER CODE

V30

Z217-030

• Includes E Tip replacement wrench * Tip is optional

12.5

• Stainless tip • Pack of 3

V- S 3

12.5 ø1.5

V-G78

Y900-166

ø 1.2

ø1.5

V-S1

Y900-161

1.2

ø1.5

V-S3

Y900-162

ø1.5

V-S33

Y900-163

Assorted Tip Kit

Y900-164

12.5

• Stainless tip • Pack of 3 ø 1.1

4.5

Super fine grade

0.9

MODEL

ø 0.8

Fine grade

• Diamond coated • Pack of 3

V-G77

NSK Satelec®

29.5

V- S 1

ø 1.2

V- G 7 9

8.3

Z217-030

12.5 ø1.5

V- G 7 8 • Diamond coated • Pack of 3

V30

ORDER CODE

• Includes E Tip replacement wrench * Tip is optional

Normal grade

V- S 3 3

12.5 ø1.5

V-G79

Y900-167

ø 1.2

Assorted Tip Kit

• Stainless tip • Pack of 3

2.6

12.5

ø 0.8

Assorted Tip Kit

Assorted Tip Kit

Y900-168

• V-G77, V-G78, V-G79 : 1 pc. each

32

( V- T i p )

Satelec® is registered trademarks of Acteon SA, France.

• V-S1, V-S3, V-S33 : 1 pc. each

Refer to the power setting chart on pages 44-45.

33


TipBook_p18-49_e.qxd

06.1.22

3:48 PM

Page 34

R E S T O R AT I V E For Minimal Intervention

G61D

G67D

Use the tip with the spherical diamond at the top. Bleeding scarcely occurs. (G61D / G62D) • Diamond coated

• Diamond coated 0.9

1.63

1.0

1.0

MODEL

ORDER CODE

7.8 NSK Satelec®

28.0

MODEL

ORDER CODE

G67D

Z217-607

7.8

G61D

NSK

Z217-601

Satelec®

28.2

G62D

G66D For anterior proximal caries. Only decayed dentin can be removed as per for molars. (G65D / G67D / G66D / G68D) • Diamond coated

• Diamond coated 1.23 1.33 0.75

1.4

7.9

7.7 NSK Satelec®

28.0

G62D

NSK

Z217-602

G65D

Satelec®

27.6

G66D

Z217-606

G68D

For molar, interdental proximal caries. The hemispherical top of the tip does not allow cutting of sound tooth. (G65D / G67D / G66D / G68D) • Diamond coated

• Diamond coated 1.33 1.63

0.75

1.0

8.0

7.6 NSK

27.9

34

Satelec®

G65D

Z217-605

Satelec® is registered trademarks of Acteon SA, France.

NSK

27.8

Satelec®

G68D

Z217-608

Refer to the power setting chart on pages 44-45.

35


TipBook_p18-49_e.qxd

06.1.22

3:49 PM

Page 36

PROSTHETICS

36

Tips for the removal of prostheses, for amalgam filling condensation are provided as well as for scaling, perio and endodontic.

37


TipBook_p18-49_e.qxd

06.1.22

3:49 PM

Page 38

PROSTHETICS Condensation / Loosening / Plugging

G21

G25

Ultrasonic vibration removes bubbles in the cement for precise cementation.

Crown removal. • Water not required

• For anterior teeth • Water not required • 3 caps supplied

MODEL

9.1

NSK Satelec®

25.7

ORDER CODE

9.0

G21

Z217-010

NSK Satelec®

23.2

MODEL

ORDER CODE

G25

Z217-205

G26

Z217-206

ø1.65

G22

G26

Ultrasonic vibration removes bubbles in the cement for precise cementation.

Post removal. • For posterior teeth • Water not required • 3 caps supplied

10.8 NSK

23.6

Satelec®

7.6

G22

Z217-020

NSK Satelec®

23.9 ø1.3

Tip Cap

G28 Amalgam condensation. • Water not required

• For G21 / G22 • Pack of 10

Tip Cap

Y140-751 9.0 NSK

• Autoclavable 22.9

38

Satelec® is registered trademarks of Acteon SA, France.

Satelec®

G28

Z217-208

Refer to the power setting chart on pages 44-45.

39


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.