Domestic Air Conditioner
SERVICE MANUAL Models HWVR08XC6 HWVR10XC6
Features Top-Discharge Air Flow Ultra Quiet Operation Safty Power Cord EnvicoCleanTMCoil Easy-Access Washable Filter Digital Display&Timer
Serial Number:
Version:00.00
Edition: 2005-8-31
Domestic Air Conditioner Model: HWVR08XC6
HWVR10XC6
Content 1、 Product Code Illumination And Series introduction 2、 Specifications
---------------------------- 2
-------------------------------------------------------------------------------- 3
3、 Safety and Precaution
----------------------------------------------------------------------4
4、Warning and Cautions
----------------------------------------------------------------------5
5、Net Dimention
---------------------------------------------------------------------------------6
6、Installation and Accessory Parts
-------------------------------------------------------7
7、Parts and Functions
-----------------------------------------------------------------------12
8、Abnormity Diagnose
-------- ---------------------------------------------------------------13
9、System Flow Chart
-------------------------------------------------------------------------14
10、Maintenance Service and Trouble Shooting 11、Wiring Diagram
-----------------------------------15
--------------------------------------------------------------------------18
12、Exploded View and Parts Lists
----------------------------------------------------19
1
Domestic Air Conditioner Model: HWVR08XC6
HWVR10XC6
Product Code Illumination And Series Introduction 1.Model identification: H W A B
C
D
E
F
G
A: Abbreviation of Haier B: Abbreviation of Window C: V-Vertical type D: Nominal cooling capacity(BTU/h) with the first two numbers based on one thousand unit E: The type of power supply X: 115V/60HZ V:208/220V/50HZ F: Function code C-Cooling only H-Heating pump E-Electric aided heating G: Design code
Examples: HWVR08XC6 It represents vertical type window air conditioner.Cooling capacity is 8000BTU/h and the power supply is 115V /60Hz. HWVR10XC6 It represents vertical type window air conditioner.Cooling capacity is 10000BTU/h and the power supply is 115V /60Hz.
2.Standard situation/conditions No.
Operating condition
Indoor air state
outdoor air state
D.B.℃
W.B.℃
D.B.℃
W.B.℃
1
Nominal cooling
26.7
19.4
35
23.9
2
Nominal heating
/
/
/
/
3
Nominal electrical heating
/
/
/
/
2
Domestic Air Conditioner Model: HWVR08XC6
HWVR10XC6
Specifications: Item
UNIT
HWVR08XC6
HWVR10XC6
Cooling capacity
BTU/h
8000
10000
Heating capacity
BTU/h
/
/
1PH/115V/60Hz
1PH/115V/60Hz
Power supply Cooling
Power input
W
840
1050
Running current
A
7.6
9.6
BTU/(hW)
9.5
9.5
Power input
W
/
/
Running current
A
/
/
BTU/(hW)
/
/
Indoor side
dB(A)
53
53
Outdoor side
dB(A)
/
/
Height
mm
520
520
Width
mm
368
368
Depth
mm
605
605
Height
mm
565
565
Width
mm
465
465
Depth
mm
670
670
Net
lbs
66
75
Gross
lbs
75
84
Type
Rotate
Rotate
Model
39R201A
44R261A
35µF / 250 VAC
60µF / 250 VAC
PSC
PSC
EER Heating
COP Sound Level
Case
Packaging dimensions Weight
Compressor
Running cap. for comp.
μF
Starting method Pressure Refrigerant Type Fan
Heating side
Psig
380
380
Cooling side
Psig
170
170
R22
R22
0.42
0.43
indoor unit
Acentric fan
Acentric fan
outdoorunit
Axial fan
Axial fan
Model Charge
kg
Fan
indoor unit
r/min
1050±30/1000±40/950±40
1050±30/1000±40/950±40
speed
outdoorunit
r/min
1050±30/1000±40/950±40
1050±30/1000±40/950±40
CFM
177
177
Moisture removal
3
M /h
2.5
3.0
Exchanging pipe type/ diameter
mm
Evaporator:φ7 condenser: φ7 Hydrophile aluminum foil
Evaporator:φ7 condenser: φ7
Air volume
Fin material
3
Hydrophile aluminum foil
Domestic Air Conditioner Model: HWVR08XC6
Safety and Precaution
4
HWVR10XC6
Domestic Air Conditioner Model: HWVR08XC6
HWVR10XC6
Warning and Cautions
Important: Test power plug before each use: 1. Press “reset “button. 2 . Press “test “button, unit should trip. 3. Press “reset” button again for use . Do not use if above test fail. In the event this device trips , the cause of the malfunction is to be corrected before further use of
5
Domestic Air Conditioner Model: HWVR08XC6
HWVR10XC6
Net Demention 368
520
605
6
Domestic Air Conditioner Model: HWVR08XC6
Installation and Accessory Parts
7
HWVR10XC6
Domestic Air Conditioner Model: HWVR08XC6
HWVR10XC6
Installation and Accessory Parts NO. 8
9
14
15
2
NAME OF PARTS
QTY
1
Curtain
1
2
Curtain Frame
1
3
Upper Guide
1
4
Side Guide
2
5
Support Bracket
1
6
Bracket
1
7
Leveling Bolt & Nut
1
8
Bolt
2
9
Nut
2
10
Side Guide Seal
1
11
Form Seal Strip
1
12
Window Track Seal
1
13
Window Locking Bracket
1
14
Screw (Type A)
10
15
Screw (Type B)
11
11 4 1 10
3
5
12
7 6
13
8
Domestic Air Conditioner Model: HWVR08XC6
HWVR10XC6
Installation and Accessory Parts
Installing Unit into A Window Window Requirements 1. These instructions are for a horizontal sliding or a casement window. 2. The electrical outlet must be within reach of the power cord. For installation in a casement window, the window frame assembly and the side of the building must be adequate to support the weight of the air conditioner.
21" min. 40 1/2" max.
15 1/2" min.
Horizontal sliding window
21 1/2" min.
15 1/2" min. 16 1/2" max.
Casement window
Horizontal Sliding Window Installation Bol t
1. Loosely attach the Support Bracket to the bottom of Bracket using Bolts, and Nuts. Attach the Leveling Bolt and Nut. (Fig. 1)
Bracke t Nut
2. Remove protective backing from Window Track Seal and apply seal to window track. (Fig. 2) 3. Measure and lightly mark a line 8-1-14 inches from window jamb. Center the Support Bracket assembly on the window track and fasten with 4 Type B screws. (Fig. 2)
Spport Bracket
Leveling Bolt & Nut
Fig. 1
Window Jamp
8 1/4 inches
4. Put the Support Bracket against the outside wall and tighten the Bolts on top of the Bracket. Adjust the Leveling Bolt so that the air conditioner will be installed with a very slight tilt(about 1/4") downward toward the outside for proper drainage. Tighten the nut. (Fig. 3) NOTE: DO NOT drill a hole in the bottom of the base pan. The air conditioner is designed to operate with the bottom of the base pan approximately half-full of water.
Type B screw Window Track Seal Window Track
Fig. 2
About 1/4"
Fig. 3
9
Domestic Air Conditioner Model: HWVR08XC6
Installation and Accessory Parts
10
HWVR10XC6
Domestic Air Conditioner Model: HWVR08XC6
Installation and Accessory Parts
11
HWVR10XC6
Domestic Air Conditioner Model: HWVR08XC6
HWVR10XC6
Parts and Functions
1. Temperature Set Knob This knob adjusts the temperature of the air. Higher the setting the cooler the air temperature. With this knob you can set the temperature to your desired comfort level. Min. Cool being the warmest and Max. Cool being the coldest. 2. Function Set Knob With this knob you can control the fan speed as well as the cooling speed. There are 3 knob positions on the COOL for you to select from. LOW will circulate air at the lowest
3. 4 Way Air Flow These air directional louvers let you control the direction of the airflow in your required direction. The airflow can be directed up- down - right side- left side. 4. Window Install Kit. Enables you to install the air conditioner in a double hung window. Extra brackets or support may be needed depending on your window.
12
Domestic Air Conditioner Model: HWVR08XC6
HWVR10XC6
Abnormity Diagnose 1. Sensor diagnose: 2 seconds after the sensors open circuit or short circuit, the unit will turn off automatically and the LED will show E0 until the sensors resume. 2. Keystroke circuit error diagnose: When power on for the first time, the PCB will check the keystroke circuit, if the sampling value is different with the theory value, the LED will show E1, which means failed keystroke circuit. The keyboard is locked and so invalid, but the remote control is working normally.
13
Domestic Air Conditioner Model: HWVR08XC6
System Flow Chart Indoor heat exchanger
Outdoor heat exchanger
Compressor
Capacillary tube Cooling
14
HWVR10XC6
Domestic Air Conditioner Model: HWVR08XC6
HWVR10XC6
Maintenance Service and Trouble Shooting
15
Domestic Air Conditioner Model: HWVR08XC6
HWVR10XC6
Maintenance Service and Trouble Shooting To store your air conditioner, after the season, remove the unit from the window as per the installation guide. Repack the unit in its original box and store away. If your unit is installed in a wall or you do not intend to remove it from the window then cover the outside with a winter cover. Before putting away your unit make sure any water left in the pan is removed and drained away. Water left in the pan could lead to Rusting
Trouble Shooting If air conditioner does not operate: Check if unit is plugged in. The plug may have come loose. Check if the unit is in "Off" mode. Air from air conditioner is warm: The COOL setting may need to be raised. o The temperature outside the room is below 65 F. The compressor o will not cycle on if the temperature outside is below 65 F. Ice formation on cooling coils: Outside temperature too cold. Set the unit on fan only setting to defrost ice. Lower temperature setting. Temperature setting may be too cold, Unit BTU may be too high for the room.
16
Domestic Air Conditioner Model: HWVR08XC6
HWVR10XC6
Maintenance Service and Trouble Shooting Air conditioner working but room not cooling: Room may have appliances that produce heat. Use an exhaust fan to remove excess heat. Vent may be in the open position. Vent has to be closed for optimum cooling. Redirect the airflow Remove any obstacles. All doors and windows need to be closed so cool air does not escape the room. Air filter may need cleaning. Unit BTU may be too low for the required cooling area. O n extreme hot & humid days air conditioners may take a little longer to cool. Air conditioner is ma king noise when cooling: You may hear sounds of air movement, water, compressor clicking on and off or window vibrations. Read O perating Guide- Normal O perating Sounds. (See page 7) Water in the a ir conditioner cabinet: This is normal as your air conditioner not only cools but also dehumidifies the air. If there is water dripping inside the room, check the installation of the unit. The unit may need to be reinstalled. (See page 12)
17
Domestic Air Conditioner Model: HWVR08XC6
HWVR10XC6
Wiring Diagram 0010556732
WIRING DIAGRAM BR: BROWN BL: BLUE G: GREEN R: RED B: BLACK W: WHITE Y: YELLOW Y/G: YELLOW GREEN
COMPRESSOR
M
~
FAN MOTOR
C R S W
M
~
LMH
OR
CAPACITOR HEAT PROTECTOR
B R
YL
CAPACITOR
B
BL
R BL B
FUSE
CN3
S2 S3 S4
S1 T3.15A 250V
4
3
CN20 COMPRESSOR
CN1
CN2
LED
N W(or Ribbed) G(or Y/G) L B(or Plain)
POWER SUPPLY
NOTE: THE DOTTED PART MAY NOT BE USED.
AMBIENT PIP. SENSOR
AMBIENT TEMP. SENSOR
18
TRANSFORMER
Domestic Air Conditioner Model: HWVR08XC6
KNOCK-DOWN DRAWINGS Model:HWVR08XC6
19
HWVR10XC6
Domestic Air Conditioner Model: HWVR08XC6
HWVR10XC6
KNOCK-DOWN DRAWINGS No. in exploded view
Spare parts number
1
0010805993
front panel a'ssy
1
2
0010706611
evaporator a'ssy
1
3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
0010203786
partition plate of evaporator
1
0010203730
centrifugal fan
1
0010203784
font paitition plate
1
0010101489
motor braket
1
0010403529
motor
1
0010203875
propeller fan
1
0010203785
rear partition plate
1
0010706621
vent-pipe a'ssy
1
0010706607
condenser a'ssy
1
0010806018
chassis a'ssy
1
0010706527
compressor a'ssy
1
0010706619
capalliary
1
0010101486
support
1
0010203778
fresh air enchanging pole
1
0010203783
wind outlet
1
0010203977
operation panel
2
0010403703
computer plate
1
0010101487
electrical box
1
0010101488
cover of electrical box
1
0010101484
casing
1
0010403603
power cable/cord/wiring
1
0010403473
remote controller
1
0010100702
clip of capacitor
1
001A3600236
compressor capacitor
1
001A3600134
fan motor capacitor
1
clip of power cord
1
0010101471
Spare parts description in english
20
Qty
Domestic Air Conditioner Model: HWVR08XC6
KNOCK-DOWN DRAWINGS Model:HWVR10XC6
21
HWVR10XC6
Domestic Air Conditioner Model: HWVR08XC6
HWVR10XC6
KNOCK-DOWN DRAWINGS No. in exploded view
Spare parts number
1
0010805993
front panel a'ssy
1
2
0010706614
evaporator a'ssy
1
3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
0010203786
partition plate of evaporator
0010203730
centrifugal fan
0010203784
font paitition plate
0010101489
motor braket
0010403529
motor
0010203875
propeller fan
0010203785
rear partition plate
0010706621
vent-pipe a'ssy
0010706607
condenser a'ssy
0010806018
chassis a'ssy
0010706528
compressor a'ssy
0010706626
capalliary
0010101486
support
0010203778
fresh air enchanging pole
0010203783
wind outlet
0010203977
operation panel
0010403703
computer plate
0010101487
electrical box
0010101488
cover of electrical box
0010101484
casing
0010403603
power cable/cord/wiring
0010403473
remote controller
0010100702
clip of capacitor
0010402227
compressor capacitor
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1
001A3600134 0010101471
Spare parts description in english
fan motor capacitor clip of power cord
22
Qty
Domestic Air Conditioner Model: HWVR08XC6
HWVR10XC6
Sincere Forever
Haier Group Haier Industrial Park, No.1, Haier Road 266101, Qingdao, China http://www.haier.com
23