Technical Bulletin 2 November 2007, Bulletin #BGM-50
BouMatic GMI+ version 6.5 Important note: Attachments:
This technical bulletin replaces TI1025 and is additional to Technical Manuals D105072 (NL), D105073 (DE), D105074 (EN) and D105075 (FR) GMI+ Calibration form (page 8), GMI+ Settings form (page 9)
Partnumber
Issue
Description
D492604 10000005
6.5 5.0/6.5
GMI+ 6.5 assembly (Sensor + bracket + Control box/Keyboard) PCB GMI+
1. Description This Technical bulletin introduces the new hard- and firmware release 6.5 of the GMI+ milk yield indicator. As from now, all GMI+ milk yield indicators will be equipped with version 6.5 firmware. Version 5.7 is not available anymore. Version 5.7 PCB’s and version 6.5 PCB’s can be mixed within one installation, unless the customer requires the new 6.5 features (See chapter 7). This new version includes: • New keyboard foil, in BouMatic style • Integrated Conductivity measurement, to indicate possible cell count problems • Improved handling of short circuits and bad and open connections on electrical outputs • New keyboard functions: Standby mode of the PCB (for service purposes) Forced Cleaning mode 2. New keyboard foil From this version, all new GMI+ assemblies will be delivered in the new BouMatic graphics style.
BouMatic Gascoigne Melotte Sprl 31, Rue Jules Melotte VAT BE 866 755 277 www.boumatic.com
4350 Remicourt - Belgium TVA FR 20 482 608 403
T +32 (0) 19 54 42 66 FORTIS 001-4391486-81
F +32 (0) 19 54 55 44 IBAN BE 36 001439148681
E info@boumatic.com SWIFT GEBABEBB
3. System settings To configure the GMI+ unit, follow the next procedure: •
In milking mode (detached), press the buttons
and
together for 3 seconds until
dCAC appears on the display.
•
Press
or
•
Press
to access Edit-mode.
•
Press
or
•
Press
to leave the Edit-mode and return back to the settings.
•
When all settings are completed, press
• •
to return to normal milking mode. Press Restart the PCB by using the Standby procedure (See point 7.2), or power off/power on the PCB.
to scroll through the settings.
to change the setting to the desired value.
or
until
END appears on the display.
PCB must be restarted to accept the new values (see line above). Setting dCAC EUCC
T-CC t-A uNiS tn C EdGE CrM diSC C1 C2 C3 t-rA t1 t2 S-G SEt0
Description Power supply mode (0=Smooth DC, 1=AC or Unregulated DC)* Short circuit detection: 0 = Switch off the corresponding output completely 1 = Switch off the corresponding output and restart after time T-CC (not recommended) Time to reset a short circuit detection (If EUCC=1) Blinking interval between actual milk yield and actual milking time Unit of measuring (0=Kg, 1=Lbs) Initial delay, automatic detach will not take place Detach level Detach delay. Unit detaches when milk flow is below detach level for this amount of seconds Vacuum attach delay. Time between initiating the cluster and opening shut-off valve Cluster venting delay. Time between closing shutoff valve and operating cylinder Milk sweep delay. Time after detach until milk sweep takes place Milk sweep open time. 0 = Milk sweep disabled Re-Attach delay. When re-attach within this time, the milk yield will be added to the actual yield Pulsation delay in Cleaning mode. When switch to Cleaning Mode, pulsation starts after this time Pulsation duration in Cleaning mode. After this time all solenoids become powerless Sheep & Goat setting (1) or Cow (0). In Sheep & Goat mode, 1 extra digit is displayed (0,01) Calibration value milk flow sensor When indication is too low, increase SEt0 When indication is too high, decrease SEt0 1 point corresponds to approximately 0.3 Kg
Technical Bulletin #BGM-50 GMI+ version 6.5 Hardware and Firmware.doc
Default
Limit
Measuring Unit
0
0-1
N/A
0
0-1
N/A
300 3
20-6000 0-200
msec. sec.
0 90 0.30 8
0-1 0-250 0.01-2.00 0-99
N/A sec. L/min. sec.
1.5
0.0-9.9
sec.
1.5
0.0-9.9
sec.
15
0-99
sec.
1.5 00.00
sec. min.,sec.
0
0.0-9.9 00.0010.00 0-200
0
0-200
min.
0
0-1
N/A
21
0-30
N/A
sec.
page 2 of 9
o-F C PM C E1 C E2 M PM M E1 M E2 iEnA
Pulsation offset enabled (1) or disabled (0) 1 0-1 N/A Pulsation rate in Cleaning mode 40 0-255 pulses/min. Pulsation ratio front in Cleaning mode 50 0-100 % Pulsation ratio rear in Cleaning mode 50 0-100 % Pulsation rate in Milking mode 60 0-255 pulses/min. Pulsation ratio front in Milking mode 60 0-100 % Pulsation ratio rear in Milking mode 60 0-100 % Conductivity measurement enabled (1) or disabled 0 0-1 N/A (0) iEdG Cell count attention level (10=100000, 20=200000 30 0-60 x 10000 etc.) somatic cells idEL First milk not considered for conductivity 3 (300 0-20 x 100 g gram) measurement dEF Reset GMI+ to default settings (1) 0 0-1 N/A * When using an Unregulated Power supply, like the GM 14 VDC Transformer D262623 (12A) or D494073 (3A), setting dCAC must be 1. * When using a smooth (switch-mode) power supply, like D390748 (13VDC, 20A), or in a Parlour Support Unit, setting dCAC must be 0. 4. • • • • • •
Power supply Although the GMI+ system can work with several types of power supplies, BouMatic strongly recommends the BGM 13VDC/20A switch-mode power supply (D390748). See drawing below. Adjust the 13VDC/20A power supply to 14,0 VDC. When using a switch-mode power supply, setting dCAC must be set to 0. Maximum 12 GMI+ units can be powered by one 13VDC/20A power supply. In case of more than 1 power supply: connect the 0VDC outputs of all power supplies with each other (1x 2.5 mm2 blue). Connect 0VDC to Earth (1x 2.5 mm2 blue).
Technical Bulletin #BGM-50 GMI+ version 6.5 Hardware and Firmware.doc
page 3 of 9
5. Wiring Diagram General notes: • The GMI+ system requires a good mains earth connection (< 6 Ohm). • Keep cables as short as possible. • Avoid tapping blocks to lengthen cables. • To avoid stray voltages, all metal parts in the parlour have to be grounded (earth). • Avoid any ragged connections. Slider connectors inside TL pulsators and Isolator TL’s must be tightened precisely.
c. d.
2
Cable between GMI+ and Cylinder (3 x 0.75 mm ). 2
Power cable (3 x 0.75 mm ). Maximum length 4 meter. Create a ‘star’ connection to cluster several power cables into 1 connection box.
e.
2
2
Main Power cable (3 x 2.5 mm ). Use 2 x (3 x 2.5 mm ) cables to wire the GMI+ units from the power supply (1 down each side of the parlour, maximum 8 GMI+ units per cable). Maximum length 25 meter.
f. g. h. i.
2
Milk/Clean Signal (3 x 0.75 mm ). Use 2 of the 3 cores. 2
Sensor cable (2 x 0.34 mm , shielded).
2
Pulsation. Cable between GMI+ and Pulsator (3 x 0.75 mm ).
2
Vacuum shut-off. Cable between GMI+ and Isolator TL (2 x 0.75 mm ).
Technical Bulletin #BGM-50 GMI+ version 6.5 Hardware and Firmware.doc
page 4 of 9
6.
Connection Diagram Fuse SMD 3,15 Amp P/N: D269580 Power In (14 VDC):
Milk/Clean Power + Power -
Green
Green Brown +
White -
White -
Brown + +
J1: Open = V6.5 Close = V5.0
Green + White -
J2: Not in use Brown Milk flow sensor
Brown
GM Cylinder: Quick start
E6 CE6
E5 IsolatorTL CE5 (DV-5) CE1 Common E2 REAR Pulsator 12/24 VOLT E1 FRONT CE4 E4
White
Solenoid
CE3 E3
Not in Use Not in Use
Termination. Close on end of comm. line (N/A) Comm. IN. From previous GMI+ or PC interface (N/A)
Shield
Brown
White
White
Brown
Shield
Comm. OUT. To next GMI+ (N/A)
KEYBOARD CONNECTOR •
For vacuum shut-off, 1 Isolator TL (D494170) is used to operate the DV5 valves (D480080) of 2 stalls. 1 side of an Isolator TL is connected to output E5 of a GMI+. The other side of the Isolator TL is connected to output E5 of the next stall. So a 2x6 installation requires only 6 Isolator TL’s.
7. New features: 7.1 Conductivity measurement • This version of GMI+ is equipped with conductivity measurement to give an attention based on the somatic cell count of the measured milk. Be aware that it’s just a rough indication. BGM doesn’t accept any responsibility for eventually not showing a cell count attention on cows which have a high somatic cell count. • If the GMI+ system records a high conductivity value (> iEdG) for a short period of time, the • •
display shows SCC1, alternating with the milk yield. If the GMI+ system records a high conductivity value (> iEdG) for a long period of time, the display shows SCC2, alternating with the milk yield. Setting iEnA enables (1) or disables (0) conductivity measurement.
Technical Bulletin #BGM-50 GMI+ version 6.5 Hardware and Firmware.doc
page 5 of 9
• •
Setting iEdG sets the attention threshold level. The attention level can be set in between 100000 and 600000 somatic cells (approximately) in steps of 10000 cells. Default is 300000. Setting idEL sets the first milk not considered for conductivity measurement. Default is 0.3 Kg. Conductivity measurement starts above this milk yield.
7.2
Standby mode
•
When in milking mode (detached), the GMI+ can be put in Standby mode by pressing the button for 2 seconds. All outputs become powerless and the display switches off.
•
button shortly to restart the PCB. It shows the version number (U6.5) followed by Press the OK. After 2 seconds the PCB is in milking mode. Ready to use.
7.3
Forced Cleaning mode
•
When in Pre-Clean mode (display shows
PrCL), the GMI+ can be put into real Cleaning mode by
button for 1 second until 00.00 appears. Release the button and CLn will pressing the appear. This option can be used in emergency situations when the milk/clean switch or wash programmer is not working correctly. •
Press the
button shortly to turn the PCB back into milking mode. Ready to use.
8. Existing features (Similar to version 5.7) 8.1 Pulsation control • This version of GMI+ can operate a GM Lectron TL pulsator (or any other 12VDC pulsator). • Adjustable pulsation rate (M PM) and ratio (M E1, M E2). • Automatic Offset calculation (o-F = 1), for optimal pulsation. Front
Front
Rear
Rear Offset (o-F = 1)
Offset (o-F = 0)
8.2 •
Central Milking / Cleaning mode This version of GMI+ can be put into Milking and Cleaning mode by a single switch, or by a wash programmer like the Aquastar (CN9/1 – CN9/2).
• •
The display shows CLn when the GMI+ is in Cleaning mode. When switch to Cleaning mode, pulsation starts after ‘Pulsation delay in Cleaning mode’ seconds. (t1). In Cleaning mode, pulsation runs at 40 pulses per minute (C PM) with a 50/50 ratio (C E1, C E2). In Cleaning mode, pulsation stops after ‘Pulsation duration in Cleaning mode’ minutes. (t2). At the same moment, all electric outputs on the PCB become powerless.
• •
Cleaning mode Shut-off valve diSC (sec) Front Rear t1 (sec)
8.3 • • • •
t2 (sec)
Milk Sweep Milk Sweep releases the remaining milk from the long milk tube after detaching, by opening the shut-off valve for a short time. Default waiting time between detaching and Milk Sweep is 15 seconds. (C2 = 15). Default open time of the shut-off valve is 1,5 seconds. (C3 = 1,5). To disable the Milk Sweep feature, setting C3 must be set to 0.
Technical Bulletin #BGM-50 GMI+ version 6.5 Hardware and Firmware.doc
page 6 of 9
Cylinder Shut-off valve
Cluster Venting delay (C1)
Milk Sweep open time (C3)
Milk Sweep delay (C2) Detach
8.4 • •
Improved Re-attachment procedure When setting t-rA is set to 30 seconds or more, after re-attachment within this time the milk yield is added to the actual yield. This is useful when there is a kick-off or cluster fall-off. The initial delay after re-attachment within time t-rA is 30 seconds (fixed).
8.5
Improved Pre-Clean procedure
•
button for 3 seconds, the cylinder releases the cluster without vacuum When pressing the and the cluster can be placed into the wash-jetters. This can be done even when other stalls are still milking. The display shows
PrCL when the GMI+ is in Pre-clean mode.
8.6
Improved Auto/Manual mode
• •
The function of the left LED has changed: When the GMi+ is in automatic mode the LED OFF during the initial delay. After the initial delay (setting tN C) the LED blinks.
•
When pressing the
9. • • • • • •
button, the GMi+ switches to manual mode and the LED
is
turns ON.
Compatibility with Version 5.0, 5.7 and 6.0 The PCB of the GMI+ 6.5 is compatible with GMI+ 5.0. By just placing a jumper (dealer supplied) on J1, the PCB is in 5.0 mode. An open jumper means the PCB is in 6.5 mode. After changing from 6.5 into 5.0 or from 5.0 back into 6.5, the settings have to be reset to default values. Use the dEF setting (dEF = 1). There is one major difference with an old 5.0 PCB: The new PCB shows CLn when in cleaning mode. The new PCB is also compatible with versions 5.7 and 6.0. PCB’s versions 5.7, 6.0 and 6.5 can work together in the same parlour, although some settings are not the same. (EUCC ,T-CC, iEnA, iEdG and iDel) Some 5.7 PCB’s already contain the Conductivity Measurement. If the settings iEnA, IEdG and idEL are accessible, conductivity measurement can be activated. The partnumber of a spare PCB 5.0/6.5 remains the same: 10000005.
BouMatic Gascoigne Melotte Sprl Research and Development
Technical Bulletin #BGM-50 GMI+ version 6.5 Hardware and Firmware.doc
page 7 of 9
GMI+ Calibration Form Dealer
Technician
Customer
Date
Address
Parlour type
Town
Parlour size
Phone no.
GMI+ version
Nr.
Milk yield Display
Scales
Difference Kg
%
SEt0
Remarks
Nr.
Milk yield Display
Scales
Difference Kg
%
Set0
Remarks
GMI+ Settings Form Dealer
Technician
Customer
Date
Address
Parlour type
Town
Parlour size
Phone no.
GMI+ version
Setting dCAC EUCC T-CC t-A uNiS tn C EdGE CrM diSC C1 C2 C3 t-rA t1 t2 S-G SEt0 o-F C PM C E1 C E2 M PM M E1 M E2 iEnA iEdG idEL dEF
Description Power supply mode Short circuit detection: Time to reset a short circuit detection (If EUCC=1) Blinking interval between actual milk yield and actual milking time Unit of measuring (0=Kg, 1=Lbs) Initial delay Detach level Detach delay Vacuum attach delay Cluster venting delay Milk sweep delay Milk sweep open time Re-Attach delay
Default Actual New value value value
New value
Limit
Unit
0 0 300
0-1 0-1 20-6000
N/A N/A msec.
3
0-200
sec.
0 90 0.30 8 1.5 1.5 15 1.5 00.00
N/A sec. L/min. sec. sec. sec. sec. sec. min.,sec.
0 0
0-1 0-250 0.01-2.00 0-99 0.0-9.9 0.0-9.9 0-99 0.0-9.9 00.0010.00 0-200 0-200
0 21 1
0-1 0-30 0-1
N/A N/A N/A
40
0-255
Pulsation ratio front in Cleaning mode Pulsation ratio rear in Cleaning mode Pulsation rate in Milking mode
50
0-100
pulses/ min. %
50
0-100
%
60
0-255
Pulsation ratio front in Milking mode Pulsation ratio rear in Milking mode Conductivity measurement enabled (1) or disabled (0) Cell count attention level
60
0-100
pulses/ min. %
60
0-100
%
0
0-1
N/A
30
0-60
3 (300 gram) 0
0-20
x 10000 somatic cells x 100 g
0-1
N/A
Pulsation delay in Cleaning mode Pulsation duration in Cleaning mode Sheep & Goat setting Calibration value milk flow sensor Pulsation offset enabled (1) or disabled (0) Pulsation rate in Cleaning mode
First milk not considered for conductivity measurement Reset GMI+ to default settings
sec. min.