1 minute read
Commonwealth of Massachusetts Title 5 Official Inspection Form
149 Bennett Rd-House
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments Property Address
Stephen Sockol Ashby
D. System Information (cont.)
6. Septic Tank (locate on site plan):
MA 01431-1
Depth below grade: feet
Material of construction: concrete metal fiberglass polyethylene other (explain)
If tank is metal, list age: years
Is age confirmed by a Certificate of Compliance? (attach a copy of certificate) Yes No
Dimensions:
Sludge depth:
Distance from top of sludge to bottom of outlet tee or baffle
Scum thickness
Distance from top of scum to top of outlet tee or baffle
Distance from bottom of scum to bottom of outlet tee or baffle
How were dimensions determined?
Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.):
Recommend yearly pumping. Tank is a 1500 gallon H20 tank. Inlet and outlet tees are PVC and of good working condition. Tank is structurally sound with no evidence of any leakage. Liquid level is at the base of the outlet invert. The center and outlet cover on tank are seized on and can’t be removed. The inlet cover is extremely heavy and needs to 2 men to remove. IT IS STRONGLY RECOMMENDED THATAMANHOLE COVER BE INSTALLED TO BRING THE INLET COVER TO GRADE.