235

Page 1

CI/SfB

BUILDERS’ METALWORK

21.9

Xt6


BUILDERS’ METALWORK Product Brochure

CONTENTS Page

Illustration Key

SPH Joist Hangers

4-5

1

Maxi Speedy Joist Hanger

6-7

2

Speedy Joist Hangers

8-9

3

Straps

10

4

Herringbone Joist Struts

11

5

Truss Clip

11

6

Wall Ties

12

7

Movement, Screw-in Starter and Cavity Ties 13 Safe Edge Frame Cramp

14

8

Screw-in Frame Ties

14

Security Mesh

14

Flat Wire Reinforcement

15

Exmet

15

Framing Anchors

16

10

Angle Plate

17

11

Angle Brackets

18 - 20

12

Timber Connectors

21

13

BAT-U-Nailplate

21

Splice Plates

22

Frame Cramp

23

Sole Plate Angles

23

Junction Clip

24

BAT Safeplate

24

Multi-purpose Fixing Band

24

Soffit Vent Mesh

25

Scrolled Hip Irons

26

Nails

26

Gallows Brackets

26

Wall Starter/UniStarter/Multi-Starter

27 - 29

9

8

14

10 15


12 4 1 14

2

9

5 11 7 15 13 3

6


EXPAMET SPH JOIST HANGERS

Design Features ● Single-piece, non- welded construction.

The BAT S.P.H. Joist Hanger is a single piece timber to masonry hanger for building into the inner leaf of external cavity walls and internal walls.

● Wider masonry flange to increase loadings on masonry of

compressive strength 2.8N/mm2 and greater. ● Manufactured from 2mm thick pre-galvanised mild steel to

BS EN 10327 : 2004, DX51D + Z600. ● 75mm load bearing surfaces.

75mm

● All hangers 150mm deep and over are manufactured 10mm less to

allow for notching and regularisation of timber joists. ● Gusset nail holes are non coaxial. ● Standard available widths 38, 44, 47, 50, 63, 75, 100, 125, 150mm.

Installation Requirements Standard Type ‘S’

The back face of hanger must be flush against the wall. The timber joist should be square cut and butting to the back face of the hanger (maximum permitted gap 6mm). A minimum height of 675mm of set masonry must be in position above the supporting flange before any load is applied. Fixing: Nail to the joist through the nail holes in each side gusset with BAT 3.75 x 30mm long square twisted sherardised nails. It is recommended that joists are notched for the base of the hanger to achieve a level surface for plasterboarding. Type ‘R’ and ‘ST’ provide additional location and alignment during construction.

Return Type ‘R’

HD Restraint Straps must be used with all types of SPH joist hangers

(‘R’ Type is a Standard type ‘S’ with Return Plate added).

to provide lateral restraint.

How to Order/Specify BAT SPH Joist Hangers TYPE ‘S’ – Please state dimensions of joist (a) depth (b) width e.g. SPHS22550 Minimum box quantity dependent on hanger size.

TYPES ‘R’ & ‘ST’ (made to order) – Please state dimensions of joist (a) depth

Straddle Type ‘ST’

(b) width

(‘ST’ Type is two Standard Joist Hangers joined together with Jointing Plate).

(c) top flange (to suit wall width) e.g. SPH22550R100 Quantity made to order

4

Both the ‘R’ and ‘ST’ Type enables the hangers to be positioned accurately whilst the masonry is built above.


EXPAMET SPH JOIST HANGERS

Safe Working Loads of the S.P.H. Joist Hanger used with various types of masonry M a s o n r y S t re n g t h 4 . 0 N / m m 2

M a s o n r y S t re n g t h 2 . 8 N / m m 2 * not available

Nominal Joist Depth (mm)

S.P.H. Hanger Depth (mm)

100 125 150 175 200 225 250 275

100 125 140 165 190 215 240 265

38 to 50

Joist Widths (mm) 63 to 75 89 to 150

3.08 3.21 3.28 3.40 3.52 3.65 3.65 3.65

2.86 2.98 3.05 3.07 3.29 3.43 3.43 3.43

* * * * * * * *

M a s o n r y S t re n g t h 3 . 5 N / m m 2 Nominal Joist Depth (mm)

S.P.H. Hanger Depth (mm)

100 125 150 175 200 225 250 275

100 125 140 165 190 215 240 265

38 to 50

S.P.H. Hanger Depth (mm)

100 125 150 175 200 225 250 275

100 125 140 165 190 215 240 265

38 to 50

Joist Widths (mm) 63 to 75 89 to 150

2.84 3.06 3.19 3.41 3.64 3.87 3.87 3.87

2.93 3.18 3.33 3.57 3.83 3.87 3.87 3.87

4.17 4.17 4.08 3.99 3.90 3.81 3.81 3.81

M a s o n r y S t re n g t h 7 . 0 N / m m 2

Joist Widths (mm) 63 to 75 89 to 150

2.67 2.86 3.05 3.25 3.44 3.63 3.63 3.63

Nominal Joist Depth (mm)

2.77 2.98 3.19 3.40 3.61 3.82 3.82 3.82

* * * * * * * *

Nominal Joist Depth (mm)

S.P.H. Hanger Depth (mm)

100 125 150 175 200 225 250 275

100 125 140 165 190 215 240 265

38 to 50

Joist Widths (mm) 63 to 75 89 to 150

3.13 3.55 3.80 4.22 4.63 5.05 5.05 5.05

4.29 4.65 4.87 5.22 5.58 5.94 5.94 5.94

4.47 4.47 4.42 4.36 4.31 4.25 4.25 4.25

5


EXPAMET MAXI SPEEDY The Maxi Speedy is a heavy duty hanger for the support of Timber to Timber or Timber to Masonry, Concrete, etc with provision for Nailing or Bolting.

Design Features ● Manufactured from 1.5mm thick pre-galvanised mild steel to

BS EN 10327 : 2004, DX51D + Z275. ● Available in 7 types: MS240; MS335; MS380; MS440; MS500; Ø4.5

● Nail hole diameter: 4.5mm

15

MS560 & MS620.

40

35 23

Bolt hole diameter: 14mm 60

● Available widths: 38, 47, 50, 63, 75, 100mm (122 + 150 for MS500,

60

560 + 620 only

Installation Requirements 55

Fixing: use BAT 3.75 x 30mm long square twisted sherardised nails.

Ø 14

Type = Blank Length mm 240/335/380/440/500/560/620

38

to 1

50

mm

75

Bend Lines Joist Width W

35

Steps to specify requirements:

40

225 (d) + 225 (d) + 38 (w) = 488mm.

Type 335*

Double joist depth and add joist width, ie for joist 225 deep x 38mm wide then:

Type 240*

1. Joist dimensions:

Type 380*

23

14 .5 44

2. The Maxi Speedy blank length must be less than

therefore select MS44038

38

20

total calculated in step 1,

225mm

d

201mm Leg Length

(not MS500 as the joist

Ø 4.5

38

to 1

00

75

hanger would stand

mm

proud). 38mm

w 6

* For lengths see calculations in How to Order.

Type 620*

Type 560*

How to Order/Specify Maxi Speedy Joist Hangers

Type 500*

Type 440*

20

M12 Bolts or Coach screws as specified by fixing manufacturer.


EXPAMET MAXI SPEEDY

Maxi Speedy Permissible Safe Working Loads (kN)

NAILS ONLY

BOLTS ONLY

Type

No. of Nails Into Face

SWL kN.

Type

No. of Bolts Into Face

SWL kN.

240

12

3.9

240

2

3.6

335

18

5.9

335

4

6.9

380

20

6.5

380

6

10.1

500

32

10.5

500

6

10.1

560

38

11.2

560

6

10.1

620

44

13.0

620

8

13.0

3.75 x 30mm long square twisted sherardised

M12 Bolts

COACH SCREWS Type

No. of Coach Screws Into Face

MASONRY ANCHORS SWL kN.

240

2

3.0

335

4

5.9

380

6

8.6

500

6

8.6

560

6

8.6

620

8

11.1

12mm ø x 63mm long (min). USING STARTER HOLES

Bolt No. of Bolts Size Into Face

SWL’s for Masonry Strengths of 20N

15N

7N

3.5N

2.8N

5.4kN

2.5kN

1.2kN

1kN

12mm

2

7.2kN

12mm

4

14.4kN 10.5kN

5kN

2.5kN

2kN

12mm

6

21.0kN 15.5kN

7.5kN

3.7kN

3kN

Indicative loads: refer to fixings supplier for recommended loads

7


EXPAMET SPEEDY JOIST HANGERS SHORT-LEG/STANDARD-LEG SPEEDY

SPEEDY MINOR

Speedy Joist Hangers provide a quick and safe method of joist SPEEDY MINOR

trimming for light and medium duty joints.

m

0.9

m

● Speedy Minor (SM) – 34mm

Light duty applications. 100mm maximum joist depth to be supported.

Depth ≤ 100 W = 38 : L = 70 W = 47 : L = 65 W = 50 : L = 64

Ø3.8mm

● Short Leg (SL) –

Medium duty applications. 175mm maximum joist depth to be L

supported. ● Standard Leg (ST) & Long Leg (LLS) – W

Medium duty applications. 225mm maximum joist depth to be

36mm

supported. ● Speedy Girder Truss Shoe (SGTS) –

Designed to offer a safe and economical method of connecting trusses to girder units. It incorporates a specially extended bearing

SHORT LEG SPEEDY

44mm

surface of 85mm. ● Long Leg Speedy (LLS) –

22 Holes Ø3.8mm

Medium duty 225mm maximum joist depth. Suitable for underslung joists (maximum 100mm drop). ● Girder/Girder Speedy – Strap

For connection of girder trusses. 0.9mm Side Gusset

L

Design Features ● Speedy Hangers

Manufactured from 0.9mm thick pre-galvanised mild steel to BS EN

X 25mm

10327 : 2004, DX51D + Z275. Hole diameter: 3.8mm. LLS manufactured from 1.5mm thick material ● Girder/Girder Speedy

Manufactured from 3mm thick galvanised mild steel to BS EN 1461.

W

Shoe

Depth ≤ 175

50mm

W = 38 : L = 191 : X = 76 W = 44 : L = 188 : X = 73 W = 47 : L = 186 : X = 71 W = 50 : L = 185 : X = 70

Hole diameter: 22mm.

How to Order/Specify Please quote type reference and joist width to be carried.

Installation Requirements

Type

Joist Width (mm)

Safe Working Load (kN)

Fixing: use BAT 3.75 x 30mm long square twisted sherardised nails Speedy Minor

SM

38, 47, 50

1.6

Speedy Short Leg

SL

38, 44, 47, 50

3.4

Standard Leg

ST

38, 44, 47, 50, 63, 75, 100

4.3

through all available nail holes. For ease of use the legs are adjustable by hand to suit all varying depths of supporting timber.

Girder Truss Shoe

SGTS

38, 44, 47, 50, 75

7.1

The depth of the supporting timber must not be less than the

Long Leg

LLS

38, 47, 50, 63, 75, 100

6.7

hanger side gusset height.

Girder/Girder Speedy

GGTS

80, 105, 120, 155

See BS 5268 : Pt2

8


EXPAMET SPEEDY JOIST HANGERS GIRDER SPEEDY

34.5mm

Strap 29 Holes Ø3.8mm

Depth ≤ 225 W = 38 L = 281 W = 44 L = 278 W = 47 L = 276 W = 50 L = 275 W = 63 L = 268 W = 75 L = 262 W = 100 L = 250

Side Gusset

0.9mm

36 nail holes Nails: 3.75 x 30mm long square twisted sherardised

Depth ≤ 225 W = 38 L = 396 W = 47 L = 392 W = 50 L = 390 W = 63 L = 383 W = 75 L = 377 W = 100 L = 365

X = 116 X = 113 X = 111 X = 110 X = 103 X = 97 X = 85

X = 137 X = 134 X = 131 X = 124 X = 118 X = 106

L

L

113mm 107mm

X

X

35mm 25mm

W

50mm

W

50mm

Shoe

LONG LEG SPEEDY (W = 38, 47, 50, 63, 75, 100)

STANDARD LEG SPEEDY (W = 38, 44, 47, 50, 63, 75, 100) 34 Holes Ø3.8m m 44m m

3 Holes Ø22mm Strap

W = 38 W = 44 W = 47 W = 50 W = 75

1.2m m

L = 271 L = 268 L = 267 L = 265 L = 252

X = 115 X = 112 X = 110 X = 109 X = 96

W = 80 W = 105 W = 120 W = 155

L = 550 L = 550 L = 550 L = 550

X = 490 X = 490 X = 490 X = 490

Side Gusset 25m m

20m m X

L

L

6 Holes Ø4mm

X

25m m W

Shoe 85m m

SPEEDY GIRDER TRUSS SHOE (W = 38, 44, 47, 50, 75)

W

120mm

GIRDER/GIRDER SPEEDY (W = 80, 105, 120, 155)

9


EXPAMET STRAPS

STANDARD STRAP

HEAVY DUTY STRAP

BAT straps are manufactured in two types. The Heavy Duty to provide horizontal restraint and Standard to provide vertical

3

restraint against wind pressure and uplift forces.

3

27.5

12. 5

Design Features

12. 5 25

● The straps are manufactured from pre-galvanised steel strips

50

Dimensions with zinc coated edges to BS EN 10327 : 2004, DX51D + Z275 or stainless steel to BS EN 10088-1 : 1995 : 1.4301.

Installation Requirements ● Nominal Dimensions

Heavy Duty - 27.5 x 5.0mm

The installation of restraint straps must comply with the current

Standard - 27.5 x 2.5mm

Building Regulations, British Standards BS 5628 : Part 1 and Part 3 and BS 8103 : Part 1, as well as NHBC recommendations.

● Hole diameters are 6mm and they are holed at 12.5mm

grouped in threes, diagonally across the width of the strap.

When straps are being fixed across joists or trussed rafters which are parallel with the wall, and where there is a gap between the wall and the first joist or truss, the gap must be packed. Noggins must be provided between each joist or truss. Fixing for Heavy Duty and Standard Straps: use either No 12 x 50mm wood screws or 4.00 dia x 75mm corrosion resistant nails. For stainless steel straps, stainless steel fixings must be used.

400 250

Anchorage of gable end to roof structure.

Fixing to wall plate and wall with one bend.

100

Floor level straps notched into parallel joists. Note: Gaps between masonry and adjacent joists must be packed.

Illustration shows the standard clockwise rotation to strap. Anticlockwise is also possible.

Floor level straps. 150 x 650mm long once bent and once twisted fixed to perpendicular joists. Note: Turn down of the strap must be in contact with the masonry.

Ordering When ordering quote the overall length and distance of bend/twist from END of strap. eg. overall length, bent at 100mm, bent at 250mm, twisted at 400mm. E.g. HD1000B100, ST1000T400 If in doubt, provide sketch.

10


EXPAMET HERRINGBONE JOIST STRUTS Herringbone Joist Struts provide stability to floor joists. Expamet Herringbone Joist Struts significantly reduce labour

Fixing Detail Single 3.75 x 30mm Sheradised Square Twisted Nail

content in fixing strutting on site.

Design Features ● Manufactured from 1mm thick pre-galvanised mild steel to BS EN

10327:2004 : DX51D + Z275. ● Suitable for joist widths between 38mm and 63mm, and joist

When fixing the second strut a 6mm (approx) gap should be kept between the struts.

depths between 150mm and 225mm. ● Available in 3 sizes:

Ref.

Joist Centres

Length

Qty/Box

400mm 450mm 600mm

480mm 523mm 660mm

50 50 50

HJS400 HJS450 HJS600

Length

Installation Requirements 57mm

Fixing: use BAT 3.75 x 30mm long square twisted sherardised nails.

30mm

Joist Span – 2.5m to 4.5m 1 Row at mid span greater than 4.5m 2 Rows at 1/3 span positions 4 Holes (both ends)

TRUSS CLIP

38 to 50

12 Holes @ 4mmØ 117.5

The Bat Truss Clip eliminates the disadvantages of skew nailing trussed rafters to timber wall plates; damaged connector plates; split rafters or wall plates.

28.5

Design Features 0.9

● Manufactured from 0.9mm thick pre-galvanised mild steel to BS EN 114.3 25.5 to 31

10327 : 2004, DX51D + Z275. ● Hole diameter:

4mm

Height: 117mm

Installation Requirements

● Available in 2 sizes:

Ref.

Width

TC38 TC50

38mm thick truss 50mm thick truss

Qty/Box 200 200

Safe Working Load Uplift (kN)

Fixing: use BAT 3.75 x 30mm long square twisted sherardised nails.

1.3 0.7

All nail holes must be filled.

● Other thicknesses of trussed rafters may be fixed using pairs of

The timber wall plate must be securely held down onto the supporting masonry.

BAT Framing Anchors, type MFAAL and MFAAR.

11


Power-Tie Wall Ties are manufactured to comply with BS EN 845 –1 the specification for ancillary components for masonry, Part 1: ties, tension straps, hangers and brackets. DD140 and EN845-1 requires specific design characteristics allowing the designer to specify the correct type of Wall Tie for each situation.

STAINLESS STEEL WALL TIES

Wall Ties should be installed in accordance with BS 5628-3, the code of practise for the use of masonry, Part 3: materials and components, design and workmanship. Stainless steel type 1.4301 to BS EN 10088-1.

BS EN 845-1 Wall Ties PART E Party Walls

Quantity

Classification

Description

PT200#50 PT200 PT225#50 PT225

75 75 100 100

5 x 50 250 5 x 50 250

Type 4 Type 4 Type 4 Type 4

200mm Housing Wall Tie 200mm Housing Wall Tie 225mm Housing Wall Tie 225mm Housing Wall Tie

MPT200#50 MPT200 MPT225#50 MPT225 MPT250

75 75 100 100 125

5 x 50 250 5 x 50 250 250

Type 2 Type 2 Type 2 Type 2 Type 2

200mm General Purpose Wall Tie 200mm General Purpose Wall Tie 225mm General Purpose Wall Tie 225mm General Purpose Wall Tie 250mm General Purpose Wall Tie

PT1-200 PT1-225 PT1-250 PT1-275 PT1-300

75 100 125 150 150

250 250 250 250 250

Type 1 Type 1 Type 1 Type 1 Type 1

200mm Heavy Duty Wall Tie 225mm Heavy Duty Wall Tie 250mm Heavy Duty Wall Tie 275mm Heavy Duty Wall Tie 300mm Heavy Duty Wall Tie

DT200 DT225 DT250 DT300

75 100 125 150

250 250 250 250

Type 2 Type 2 Type 3 Type 3

200mm Double Triangle Wall Tie 225mm Double Triangle Wall Tie 250mm Double Triangle Wall Tie 300mm Double Triangle Wall Tie

A

TYPE

External Walls

B

PART E

TYPE

Domestic and small commercial up to 15m high.

External Walls

B

PART E

TYPE

Most masonry cavity walls.

External Walls

Nominal Cavity Width (mm)

TYPE

Domestic up to 2 storey, 10m high. Part E (Separating Walls). Type A compliant.

PART E

Type Reference

B

250

SSCD

Thin Joint Masonry Ties

Insulation Retaining Disc. Fits all Ties.

PTJ4115 PTJ4135 PTJ4165

50 75 100

250 250 250

Type 4 Type 4 Type 4

Thin Joint Masonry Tie Thin Joint Masonry Tie Thin Joint Masonry Tie

SSFS SSFS75 SSFS100

50 75 100

250 250 250

Type 6 Type 6 Type 6

Timber Frame Tie including nail Timber Frame Tie including nail Timber Frame Tie including nail

Domestic up to 2 storey, 10m high. Maximum block density 550 kg/m3.

Timber Frame Tie

Allow for maximum height displacement of 24mm. For our full range of cavity wall ties and ancillary fixings please see

www.expamet.co.uk/expamet-powertie

12


Movement joints are necessary in masonry wall panels to cater for the natural movement of buildings. Tensile and compressive forces can develop that lead to cracking and bowing of walls. BS5628-3 details the provision of movement joints in clay, calcium silicate, concrete and stone masonry.

STAINLESS STEEL MOVEMENT TIES

Power-Tie Movement Ties allow expansion and contraction at movement joints whilst providing shear resistance between adjacent panels and supports. Placing the sleeve on the plain end of the movement tie with 10mm clearance, debonds the tie from the mortar joint, permitting longitudinal movement.

Straight Movement Tie with debonding sleeve.

L

H

Bent Movement Tie with debonding sleeve.

Type Reference

Size (mm)

Quantity

Description

SMT200 SMT225 SMT250

L:200 L:225 L:250

100 100 100

Straight Movement Ties are built into the corresponding bed joints of adjacent panels.

BMT 100 BMT 150 BMT 200

L:100 / H:50 L:150 / H:50 L:200 / H:50

100 100 100

Bent Movement Ties are mechanically fixed to adjacent supports. Slotted end provides vertical adjustment.

L

STAINLESS STEEL SCREW-IN STARTER AND CAVITY TIES

SST

Quick and easy method to tie new walls to existing walls. Screw-in Starter and Cavity Ties are made from austenitic stainless steel to BS EN 10088-3. Supplied with masonry plug.

SCT

Type Reference

Length (mm)

Quantity

Description

SST130#10 SST130

130 130

10 100

Screw-in Starter Tie Screw-in Starter Tie

SCT 150 SCT 180 SCT 200 SCT 225

150 180 200 225

100 100 100 100

Screw-in Cavity Tie with V Drip Screw-in Cavity Tie with V Drip Screw-in Cavity Tie with V Drip Screw-in Cavity Tie with V Drip

Nominal cavity width for SCT: 50 - 100mm. 13


2

19

50

26

6 Dia Holes

50

EXPAMET SAFE EDGE FRAME CRAMPS AND SCREW-IN FRAME TIES

10

8

100 / 150 / 200

Screw-in Frame Ties secure timber window and door frames to inner leaf of masonry. Ref.

Material

Size (mm)

Qty per box

SIFT130RT SIFT130#10

Stainless Steel Stainless Steel

130 130

100 10 bags of 10

BAT Safe Edge Frame Cramps provide positive location of window and door frames to inner leaf of masonry. Manufactured from pre-galvanised steel strip with zinc Bright Zinc Plated Steel

SIFT

150

coated edges to BS EN 10327:2004 : DX51D + Z275.

100

Fixing: use 2 No 4.5mm nails or No. 8 screws, galvanised or sherardised.

SIFT130

SIFT

Ref.

Width

Length

Upstand

Qty/Box

SEFC150 SEFC200 SEFC250

19mm 19mm 19mm

100mm 150mm 200mm

50mm 50mm 50mm

125 125 125

EXPAMET SECURITY MESH

50-73HFG 50-73HF

50-89HRG 50-89HR

50-76MFG 50-76MF

(Above shown at approx 50% actual size)

A cost effective way of securing buildings or internal spaces by sandwiching a layer of steel mesh into the walls and ceilings during construction. Available in a range of gauges this high quality security mesh is suitable for internal walls, ceilings, partitions and external brickwork. It can also be provided in galvanised steel, where damp conditions are expected. See our full range of Expanded metal and lath at www.expamet.co.uk

Ref.

Description

Mesh LW

Mesh SW

Strand Strand Weight Width Thickness Kg/m2

50-73HFG 50-89HRG 50-76MFG

Security Mesh - Flattened Security Mesh - Raised Security Mesh - Flattened

42.9 50.8* 43.4

14.2 22.6* 18.0

4.6 3.1 2.3

2.7 3.0 1.1

50-73HF 50-89HR 50-76MF

Security Mesh - Flattened Security Mesh - Raised Security Mesh - Flattened

42.9 50.8* 43.4

14.2 22.6* 18.0

4.6 3.1 2.3

2.7 3.0 1.1

* Mesh pitch size

14

Sheet Size

Material

8.59 6.52 1.85

2440 x 1220 2440 x 1220 1250 x 2500

Galvanised Steel to BS EN ISO 1461 Galvanised Steel to BS EN ISO 1461 Galvanised Steel to BS EN ISO 1461

8.59 6.52 1.85

2440 x 1220 2440 x 1220 1250 x 2500

Hot Rolled Mild Steel Hot Rolled Mild Steel Cold Rolled Mild Steel


FLAT WIRE REINFORCEMENT For structural applications

Power-Tie Flat Wire Ladder Reinforcement is made from austenitic stainless steel to 1.4301 : BS EN 10088-3. Ladder length 2700mm. Conforms to BS 5628-2. 500N/mm2 minimum tensile strength. Special designs are available on request for corners and T-shapes.

Reference

Type

Main Wire Height (mm)

Equivalent Round Wire Diameter (mm)

Ladder Width (mm)

Wall Width (mm)

Qty

SBSF3060 SBSF30100 SBSF30150 SBSF30175

Single Leaf Single Leaf Single Leaf Single Leaf

2.8 2.8 2.8 2.8

3 3 3 3

60 100 150 175

100 140/150 190/200 215

20 20 20 20

SBSF3560 SBSF35100 SBSF35150 SBSF35175

Single Leaf Single Leaf Single Leaf Single Leaf

2.9 2.9 2.9 2.9

3.5 3.5 3.5 3.5

60 100 150 175

100 140/150 190/200 215

20 20 20 20

SBSF4060 SBSF40100 SBSF40150 SBSF40175

Single Leaf Single Leaf Single Leaf Single Leaf

3 3 3 3

4 4 4 4

60 100 150 175

100 140/150 190/200 215

20 20 20 20

SBSF4560 SBSF45100 SBSF45150 SBSF45175

Single Leaf Single Leaf Single Leaf Single Leaf

3 3 3 3

4.5 4.5 4.5 4.5

60 100 150 175

100 140/150 190/200 215

20 20 20 20

SBSF5060 SBSF50100 SBSF50150 SBSF50175

Single Leaf Single Leaf Single Leaf Single Leaf

3 3 3 3

5.0 5.0 5.0 5.0

60 100 150 175

100 140/150 190/200 215

20 20 20 20

Overlap ends 225mm.

EXMET REINFORCEMENT For non-structural applications

Stainless steel Exmet is manufactured from austenitic stainless steel 1.4301 to BS EN 10088-1. Coil length 20m. Expanded steel mesh with no joints or interweaving to fail under stress.

Ref

Material Thickness (mm)

Coil Size Width (mm)

Wall Width (mm)

Quantity

76820

0.3

65

100

5

76920

0.3

115

140

5

77020

0.3

175

225

1

77120

0.3

225

265

1

Overlap ends 75mm. 15


EXPAMET FRAMING ANCHORS MFAAR MFABL (right handed) (left handed)

MFAAL (left handed)

MFABR MFAC (right handed)

BAT Multi-Grip Framing Anchors offer the most effective and TYPE MFAAL

economical method of providing strong, mechanical joints for framing of timbers 29 26 18

29 26 18

Five types available: AL, AR, BL, BR and C.

15

MFAAL & MFAAR: for anchoring rafters and trusses to wall plate.

10 35

40 55

60

MFABL & MFABR: for anchoring headers to studs, beams to posts and studs to plates. MFAC:

for right or left handed use – for anchoring joists to

127

beams, stringers to headers and hip joints.

43 32

Design Features

26 8 33. 5

â—? Manufactured from 1mm thick pre-galvanised mild steel

to BS EN 10327 : 2004, DX51D + Z275.

TYPE MFABL Overall height:

127mm

Width: 34mm 15

Hole dimension: 4mm

15 40

200 no. per box

40 60

60

127

Installation Requirements Framing anchors must always be used in pairs to minimise eccentric loading. 43

Recommended fixing: BAT 3.75 x 30mm long square twisted

32

26 8

sherardised nails.

33. 5

Note: Use all available timber facing holes.

TYPE MFAC Safe Working Loads: 10

Longitudinal Loads

15

Types A & B: longitudinal capacity 1.3kN/pair

s oad ral L Late

60

55

lateral capacity 1.1kN/pair 127

Type C: longitudinal capacity 3.7kN/pair 32

32

26

26 11

8 10 20 28

16

35

40

10 20 28


EXPAMET ANGLE PLATE BAT Angle Plates are used as a safe and economical method of connecting joists to purlins.

Design Features â—? Manufactured from 2mm thick hot dipped pre-galvanised

mild steel to BS EN 10327 : 2004, DX51D + Z275. â—? Safe Working Loads:

1 pair = 3.5kN 2 pairs = 7.5kN

Ref: AP30030

300mm x 30mm x 30mm

50 per bag

Installation Requirements Fixing: use BAT 3.75 x 30mm long square twisted sherardised nails. Use all timber facing nail holes. Minimum timber depth of 150mm. Ensure the timbers project a minimum of 50mm beyond the Angle Plates.

Steel Beam

150mm minimum

Timber packer in beam (bolted) .

17


EXPAMET ANGLE BRACKETS BAT Angle Brackets are designed for multi-purpose fixing applications and can be

LIGHT DUTY

used as replacement cleats, nailed or bolted.

Design Features

Ref: AB604060 60mm x 40mm x 60mm 12 holes @ 4.5mm ø 100 no. per box

A B

● Manufactured from hot dipped pre-galvanised

38

mild steel to BS EN 10327 : 2004, DX51D + Z275. ● Light Duty:

AB604060 2mm thick

● Heavy Duty:

60

HD9090; HD15090; HD150150

5.5

12

2 25

12

5.5

2mm thick, ribbed

VIEW ON B 12

18.5

12

5.5

Installation Requirements

25

12

5.5

14 6

11x30

Angle Brackets may be used for timber/timber,

11

14

timber/steel and timber/masonry connections.

Ø7

Ø7

16

9 Ø 11

May be fixed with nails, bolts or coach screws. Must be used in pairs.

Nailed Safe Working Loads kN (per pair) Type

Uplift

Shear

AB604060

1.2

1.8

HD9090

1.6

3.6

HD15090 HD150150

1.4

4.6

14

HEAVY DUTY VIEW ON A 10

BS 5268 Pt 2 Long term loads Nails 3.75 x 30mm long square twisted sherardised

14

VIEW ON A

17. 5

17. 5

35

Ref: HD9090 87mm x 87mm x 59mm 16 holes @ 4mm ø 50 no. per box

10

7 10 Ø9

Uplift 11x30

59 Ø9

Shear

VIEW ON B 59 22. 5

32

17

Stiffening Rib

13

Ø 11

42

B A 87

Ø9

17 Ø9

87

18

2

27 59


EXPAMET ANGLE BRACKETS

10

17.5

17.5

35

10

HEAVY DUTY

7 10

Ref: HD15090 90mm x 150mm x 63mm 20 holes @ 4mm ø 50 no. per box

Ø 9

11x30

63

VIEW ON C

Ø 9

63 10

32

7 10

22. 5

17

22 Stiffening Rib

11x30 30

C

51 30

D

Ø 11

VIEW ON D 17.5

150

17.5

90 (TYP)

42

Ø 9 35

17

Ø 9 10

90

27

2

63

11

25

25

30

30

29

6

HEAVY DUTY

10

10

Ref: HD150150 150mm x 150mm x 63mm 20 holes @ 4mm ø 40 no. per box

Ø9

Ø9 11x30

VIEW ON E

63 Ø9

23

54

30

26

Stiffening Rib 24 11x30

53

150

Ø9

VIEW ON F

F 30

E Ø9

Ø9 10 150

2

31 63

19


EXPAMET ANGLE BRACKETS B

Light Duty Angle Brackets

C

A

B

T & L Jointing Plate

Ref

Size (mm) A x B x C

Qty

AB303015

30 x 30 x 15

100

AB404040

40 x 40 x 40

100

AB505035

50 x 50 x 35

100

AB604060

60 x 40 x 60

100

AB804042

80 x 40 x 42

50

AB808018

80 x 80 x 18

50

AB906059

90 x 60 x 59

50

AB909060

90 x 90 x 60

50

AB1006060

100 x 60 x 60

50

AB12512542

125 x 125 x 42

50

AB1509059

150 x 90 x 59

50

AB15015063

150 x 150 x 63

50

A2

B

Ref

Size (mm) A1 x A2 x B Qty

T1408030

140 x 80 x 30

20

L12012020

120 x 120 x 20

20

A1 B

A2 C

Adjustable Angle Brackets Ref

Size (mm) A x B x C

Qty

AAB1403540

140 x 35 x 40

50

AAB806520

80 x 65 x 20

20

A1 A

B

Flat Jointing Plate B

Nail Plate Brackets

C

A

Ref

Size (mm) A x B x C

Qty

NPA767676

76 x 76 x 76

50

NPA575751

57 x 57 x 51

50

Ref

Size (mm) A x B x C

Qty

AP2103030

30 x 30 x 210

50

AP3003030

30 x 30 x 300

50

A

B

B

A

20

Angle Plates

C

B

Ref

Size (mm) A x B

Qty

JP17559

175 x 59

50

JP46250

250 x 46

50

JP63300

300 x 63

50


EXPAMET TIMBER CONNECTORS

BAT Timber Connectors are made in accordance with the requirements of BS EN 912 : 2000 ‘specification for connectors for timber’. Safe working loads, end distances and spacing are all set out in BS 5268 Part 2.

SHEAR PLATE 102

SHEAR PLATE 67

Shear Plate

Tooth Plate (Round)

Split Ring

Manufactured in 2 sizes: SPT67 (B2) x 150 per box and SPT102 (B3) x 50 per box Designed for use with M20 bolt.

Manufactured in 3 sizes: 50, 63 and 75 diameter. 200, 150 and 100 per box respectively.

Manufactured in 2 sizes: SRTC64 (A3) x 100 per box and SRTC102 (A3) x 100 per box

Material Specification: 67mm – Manufactured from galvanised hot rolled steel to BS EN 10025.

Available in both single and double sided, eg. ref. TCSS (C6); TCDS (C7) etc.

Designed for use with M12 and M20 bolts respectively.

100mm – Galvanised cast iron to BS EN 1562.

Suitable for M12 bolt.

Material Specification:

Material Specification:

Manufactured from galvanised hot rolled steel to BSEN10025.

Double bevelled.

Manufactured in 1 size: SPW50 (50mm square). To suit 12mm bolt.

Manufactured from pre-galvanised steel to BS EN 10327 : 2004 DX51D + Z275.

250 per box.

Application Tools

Square Plate Washers

Bolts are not supplied with timber connectors.

For use with timber connectors. Available to special order.

REF

TYPE

SRGT/64

Split Ring Grooving &Dapping Tool

SIZE mm 64mm split ring

SRGT/102

Split Ring Grooving &Dapping Tool

102mm split ring

DT/67

Shear Plate Grooving &Dapping Tool

67mm shear plate

DT/102

Shear Plate Grooving &Dapping Tool

102mm plates

BAT-U-NAIL PLATE 354 305 254

BAT-U-Nail is a plate system which enables timber structures

203 152 100

to be made on site or in the builders workshop, since it is

51

nailed by hand.

Design Features BS EN 10327: 2004 : DX51D + Z275.

152 114 76 19

● Widths: 76, 114 and 152mm ● Lengths: 51, 100, 152, 203, 254, 305 and 354mm.

50.8

DIRECTION OF STIFTENING RIBS

Installation Requirements

12.7

Ø3. 5

● Various quantities per box. Ref. eg. BP7651.

345 N/nail (parallel to timber grain). 145 N/nail (perpendicular to timber grain).

Fixing: use BAT 3.75 x 30mm long square twisted sherardised nails –

Plate compression value 40 N/mm width of plate. To calculate capacity of connections, the lesser of anchorage, plate compression and tension should be taken.

Loading in the direction of the plate stiffening ribs.

Fix in accordance with BS 5268 : Part 2.

BAT-U-Nail plates are to be fixed on both sides of the timber.

4.75 ± 1.5

● Manufactured from 0.9mm pre-galvanised mild steel to

21


EXPAMET SPLICE PLATES

Suitable for butt jointing timbers of similar cross section.

Design Features ● Manufactured from 1.2mm thick pre-galvanised mild steel to

BS EN 10326 : 2004 S280GD + Z275. ● Available in 3 types:

L61

61 x 400mm long

up to 150mm deep joist

L80

80 x 560mm long

up to 200mm deep joist

L98

98 x 560mm long

up to 250mm deep joist

● 8 sets of 4 per box (32 pieces) including nails.

Installation Requirements

18 mm

Joint consists of 4 pieces. All nail holes must be used. Minimum timber thickness 50mm.

L61

18 mm

Can be used for: 400mm

● Replacement of rotten and decayed floor joist ends. 61mm

● Replacement of fire damaged structural timbers. ● Making good localised damage or decay in structural timber work. 18 mm

L80 560mm

Joist Depth

Splice Plate Code

Splice Plate Size (mm)

Resistance Moment (kNm)

Shear Capacity (kN)

Approx. Nails per plate

125 150

L61

18 x 61 x 400

1.5

13

27

175 200

L80

18 x 80 x 560

1.5

13

52

225 250

L98

18 x 98 x 560

1.5

13

65

80mm

L98 560mm 98mm

Timber Joist

Existing Joist

22


EXPAMET FRAME CRAMP To provide positive location and support of window from timber framing to resist wind and incidental loadings.

Design Features ● Manufactured from 0.9mm thick hot dipped galvanised

mild steel to BS EN 10327 : 2004 DX51D + Z275. ● Available in 2 sizes:

Ref.

Width

Length

Upstand

Qty/Box

FC1 FC2

76mm 76mm

202mm 212mm

40mm

100 100

Installation Requirements Fixing: use BAT 3.75 x 30mm long square twisted sheradised nails.

PLAN VIEW

SOLE PLATE ANGLES

BAT Sole Plate Angles positively locate timber sole plates to concrete floor slabs using masonry fixings as required, without penetrating the dpc.

Design Features ● Manufactured from 0.9mm thick hot dipped galvanised

mild steel to BS EN 10327 : 2004 DX51D + Z275. ● Available in 2 sizes:

Ref.

Width

Length

Upstand

Qty/Box

SPA112 SPA162

76mm 76mm

112mm 162mm

40mm 40mm

100 100

Installation Requirements BAT Sole Plate Angles may be fixed on the inside of the sole plate or alternatively fixed under the sole plate with the upstand on the outside of the sole plate. Fixing: use 3.75 x 50mm minimum length nails/masonry nails.

SECTION VIEW 23


EXPAMET JUNCTION CLIP

BAT SAFEPLATE

For protection of plumbing and electrical wiring against random nailing into studs.

Can be used instead of noggins, at wall junctions and at contact points between ceiling and walls when fitted at 300mm centres.

Design Features

Design Features

● Manufactured from 1mm hot dipped galvanised ● Manufactured from 1mm hot dipped galvanised mild

mild steel to BS EN 10327 : 2004 : DX51D + Z275. Ref: SAF1 90 x 54mm 200 per box

steel to BS EN 10327 : 2004 : DX51D + Z275. Ref: JC1 250 per box.

Installation Requirements

Installation Requirements

Use wherever services occur within 75mm of face of plasterboard or 100mm of surface of floor deck. Fixing: Tap in with hammer.

Fixing: use BAT 3.75 x 30mm long square twisted sherardised nails or ordinary plasterboard nails.

MULTI-PURPOSE FIXING BAND 6.25 Dia

3.8 Dia

41 4 12

17 58 Pitch

Expamet Fixing Band is an easy-to-use coil strip designed for all types of light fixing applications.

29

Design Features ● Manufactured from hot dipped galvanised mild steel to

BS EN 10327 : 2004 DX51D + Z275. ● Available in 3 sizes

Ref.

Width

MFBA 20mm MFBB 20mm MFBA/20 20mm

Thickness

Length

0.9mm 0.7mm 0.9mm

10 metre coil 10 metre coil 20 metre coil

Installation Requirements Pipe fixing, General support & Duct work

24

Clamping, Bracing & Restraining

Timber repair... Fencing, Garden Sheds etc

Fixing: use BAT 3.75 x 30mm long square twisted sherardised nails, screws or bolts. Not to be used below ground.


EXPAMET SOFFIT VENT MESH

Examples of Applications

75 x 50mm fixing block

The provision of eaves vents to limit condensation risk is a requirement of the Building Regulations. Expamet expanded stainless steel is used over the vents to exclude birds and insects. This mesh is an economical material for the purpose. It is readily adaptable to various eaves details, is light in weight and easy to handle on site. Coils of mesh in convenient dispensers make site work easier and avoid wastage.

Design Features â—? Manufactured from stainless steel to

BS EN 10088-1 : 2005 : 1.4404. â—? Approx. weight 0.370kg/m2. Soffit board rebated to fascia board

Ref: SVM1 30m x 75mm.

Installation Requirements Mesh fixed to soffit board prior to fixing of soffit board Mesh bent to shape required

Mesh bent to shape required

Mesh fixed to rear of fascia board

Stainless steel nails or staples should be used for fixing the eaves vent mesh. Closed area 34%. The vent gap should be increased to 15mm or 38mm to compensate.

Predrilled ventilation hole

Soffit mesh fixed along the back of fascia board

Mesh held in position by soffit board

Mesh fixed to rear of fascia prior to fixing fasci

Mesh bent to shape required and compressed to fill gap on fixing of fascia board

Mesh is fixed to rafter ends, bent and returned to underside

Fascia and soffit boards are then fixed

25


EXPAMET SCROLLED HIP IRONS Designed to provide decorative restraint when bedding hip tiles.

Ref HIP2003 HIP2503 HIP3003 HIP3004

Material Galvanised Galvanised Galvanised Galvanised

Length x Width x Thick 200mm x 25mm x 3mm 250mm x 25mm x 3mm 300mm x 25mm x 3mm 300mm x 25mm x 4mm

Height 100mm 150mm 150mm 150mm

Height

Thick

Width Length

NAILS

Stainless Steel Annular Ring Nails SSRN 3.35 x 50mm

1000 per box

Sherardised Nails SN32 BAT 3.75 x 30mm twisted 1000 per box SN321 BAT 3.75 x 30mm twisted 10000 per box

GALLOWS BRACKETS

The Gallows Bracket provides a method of supporting

Depth

otherwise unsupported brickwork. Manufactured from 50 x 50 x 5 angle, red oxide finish. Two sizes are available (supplied in pairs). To suit M12 Masonry Anchors - not supplied. Height Red Oxide: MH375375

375mm high x 375mm deep (projection from wall)

MH490375

490mm high x 375mm deep (projection from wall)

26


EXPAMET WALL STARTERS, UNISTARTERS AND MULTI-STARTERS

Wall Starters Individual products designed for specific widths of new walls There are four ‘flanged’ products in the Expamet Wall Starter range, each designed for a specific wall widths, from 60mm to 260mm thick.

The quick, easy-to-fix way to tie-in new walls to existing walls

Stainless Steel Ref. WS060

Stainless Steel Ref. WS090

Stainless Steel Ref. WS120

Stainless Steel Ref. WS185

Plastisol Coated Galvanised Steel Ref. WGC060

Plastisol Coated Galvanised Steel Ref. WGC090

Plastisol Coated Galvanised Steel Ref. WGC120

Plastisol Coated Galvanised Steel Ref. WGC185

For lightweight block walls 60 to 75mm thick.

For brick or block walls 100 to 115mm thick.

For brick or block walls 125 to 180mm thick.

For brick or block walls 190 to 260mm thick.

without cutting out brickwork. Suitable for walls of up to three storeys high, ie up to 8m maximum.

UniStarters

Wall Starters Ref

Description

Type

Wall Thickness

The universal wallstarter for any wall

WS060

Stainless Steel

Single Flange Integral Tie

60 - 75mm

The flat flange-free design of Expamet UniStarters means they can

WS090

Stainless Steel

Single Flange Integral Tie

100 - 115mm

WS120

Stainless Steel

Single Flange Integral Tie

125 - 180mm

WS185

Stainless Steel

Single Flange Integral Tie

190 - 260mm

WGC060

Plastisol Coated Galv

Single Flange Integral Tie

60 - 75mm

WGC090

Plastisol Coated Galv

Single Flange Integral Tie

100 - 115mm

WGC120

Plastisol Coated Galv

Single Flange Integral Tie

125 - 180mm

WGC 185

Plastisol Coated Galv

Single Flange Integral Tie

190 - 260mm

be used to construct any wall between 75mm and 250mm thick – one product, multiple applications.

UniStarters UWSS

Stainless Steel

No Flange Integral Tie

Up to 250mm

UWGC

Plastisol Coated Galv

No Flange Integral Tie

Up to 250mm

Multi-Starters MSSS

Stainless Steel

No Flange Turn-n-slide Ties

Up to 250mm

MSGC

Plastisol Coated Galv

No Flange Turn-n-slide Ties

Up to 250mm

MSGFIX

Plastisol Coated Galv

Extra Fixing Pack

MSGFIX

Stainless Steel

Extra Fixing Pack

Contains 10 ties, 5 screws, plugs & washers

All Wall Starters, Unistarters and Multistarters are supplied with the necessary fixings.

Stainless Steel Ref. UWSS

Plastisol Coated Galvanised Steel Ref. UWGC

27


EXPAMET WALL STARTERS & UNISTARTERS FIXING INSTRUCTIONS

WALL STARTERS

Wall Starter & UniStarter Installation

CAVITY WALLS – Brick & Block The left hand Wall Starter is fixed with its ties extending upwards ready

● Suitable for both metric and imperial brick/block sizes.

for bending down into the mortar courses. The right hand Wall Starter is ● Integral ties are designed to tie into every (225mm deep) block

inverted and fixed with the ties extending downwards.

course or every third course of (75mm deep) bricks. They must then be bent upwards ready for setting into the mortar course ● Each pack contains two 1175mm lengths. Slotted holes at each end

as the wall is built.

allow easy connection of one length to the next. ● Full fixing instructions and all necessary coach screws, washers

UNISTARTERS

and plugs are provided. Only 5 fixings are needed for the two CAVITY WALLS – Brick & Block

lengths (Type 120 and 185 Wall Starters are supplied with UniStarters are fixed with their ties extending upwards ready for bending down into the mortar courses. The right hand UniStarter is higher to allow

10 fixings). The only tools you need are: spirit level, drill (with 10mm masonry bit) and 10mm spanner.

the tie to bed into the first blockwork mortar course. ● Miscoursing of up to 50mm can be solved by simply bending

integral ties to suit. This will reduce the length of ‘built-in’ tie, but it still meets relevant test criteria. ● All products are designed to allow up to 10mm vertical movement. ● If the upper end of the product extends past the top line of your

wall, use tin-snips or a hacksaw to cut off the excess and attach ine

Tie-l

e

Tie-lin

using the remaining top fixing hole. ● Align the centreline of the UniStarter with the centre of the new

wall. Align the flanged edge of the Wall Starter to the front or back e

Tie-lin

ine Tie-l

of the new wall. ● For cavity walls, each leaf will require a separate starter. ● All external walls require a 10mm wide weather seal to be fitted

The distance between the flanges sets the cavity width.

Dimension to suit centralising of UniStarters in leaves of new wall.

between the product and the existing wall or applied to the raked-out vertical joint. ● In exposed locations (or to meet Local Authority specifications),

a vertical DPC should be cut into the existing wall prior to fixing fixing points

the product.

675

450

either hole may be used

28

slot

flat slot 25

675

450

joining adjacent Wall Starters, and UniStarters

either hole may be used

drill, plug and fix using fixings supplied


EXPAMET MULTI-STARTERS

Multi-Starters Featuring a ‘turn-n-slide tie’ to accommodate all sizes of brick/block. The Multi-Starter is suitable for all wall widths from 60mm-250mm.

Installation ● The turn-n-slide ties enable the starter to be tied into any course

the builder wishes, ideally every (225mm deep) block course or every third course of (75mm deep) bricks. ● Each pack contains two 1165mm lengths. Slots at each end allow

easy connection of one length to the next. ● For more information see Wall Starter & UniStarter installation Stainless Steel Ref. MSSS

Plastisol Coated Galvanised Steel Ref. MSGC

details on previous page.

Fixing Details Insert

Turn

Fixing points

Slide

(anti-clockwise)

Joining adjacent Multi-Starters

675

450

675

For Masonry Movement Joint applications – use Expamet Movement Ties.

Drill, plug and fix using fixings supplied

450

PLUMB

DRILL

FIX

BUILD

Ensure existing wall is sound and clean. Locate the starter above the DPC. Plumb the section and mark positions of the fixing holes.

Drill and plug the existing wall, taking care to avoid mortar joints.

Lightly screw the first length to the existing wall over weatherseal if required, then plumb, mark and drill out the next starter. Make sure that the slot at the end of one length always lies on top of the slot of the adjacent length. Tighten all screws when all required lengths are in position.

Lay bricks or blocks, be sure to bed them with mortar against the starter. Multi-Starter: Turn-n-slide ties into the mortar as you build. Wall Starters and UniStarters: Bend ties into the mortar as you build. Seal vertical joint with proprietary flexible sealant.

29


CONSTRUCTION FIXINGS HEALTH AND SAFETY DATA SHEET

1. IDENTIFICATION

8. EXPOSURE CONTROLS Wear personal protection such as gloves and safety goggles when handling products. Some products may have a film of soluble cutting fluid after manufacture; therefore carry out personal hygiene, including proper washing of hands, after contact.

Expamet Construction Fixings Expamet Building Products Limited Greatham Street Longhill Industrial Estate (North) Hartlepool TS25 1PR Tel: +44 (0)1429 866688 Fax: +44 (0)1429 866633

2. HAZARDS IDENTIFICATION

9. PHYSICAL AND CHEMICAL PROPERTIES Construction Fixings are supplied in various lengths, widths and gauges. Metallic grey appearance.

10. STABILITY AND REACTIVITY Construction Fixings are stable under normal conditions but if subjected to high temperatures, fumes are produced.

Possible cuts from steel edges. Toxic and irritant fumes from high temperatures.

11. TOXICOLOGICAL INFORMATION 3. COMPOSITION Galvanised steel DX51D+Z275 to BS EN 10327: 2004 DX51D+Z600 to BS EN 10327: 2004 S280GD+Z275 to BS EN 10326: 2004 Stainless steel 1.4301 to BS EN 10088-1: 2005

High temperatures can produce fumes.

12. ECOLOGICAL INFORMATION No known hazard.

13. DISPOSAL CONSIDERATIONS Recycle or dispose of in accordance with Waste Management Licensing Regulations.

4. FIRST AID MEASURES Skin and eye contact: treat cuts from steel edges as required. Ingestion: not applicable. Inhalation: remove from source of fumes and dust.

14. TRANSPORT INFORMATION Not classified as hazardous for transport.

15. REGULATORY INFORMATION 5. FIRE FIGHTING MEASURES Non-flammable material.

Construction Fixings are articles and have no obligations under REACH.

6. ACCIDENTAL RELEASE MEASURES

16. OTHER INFORMATION

Not applicable.

All products must be installed in accordance with Expamet Building Products’ published instructions.

7. HANDLING AND STORAGE

Where structural products are to be removed from an existing installation, care must be taken to ensure that the procedure does not compromise the loading/installation restrictions applicable to the products.

Bands and straps must not be used for lifting. Use suitable PPE when handling the Construction Fixings. Assess manual handling risks before lifting. Construction Fixings should be stacked on firm level ground in dry conditions.

The Construction Fixings Health and Safety Data Sheet is not a product specification guide.

Any arrangement of construction fixings shown in this brochure is indicative only. Actual fixing installations must comply with current Health and Safety requirements.

30


QUALITY YOU CAN TRUST Expamet are not only industry leaders in the UK, but we also operate in continental Europe and the Middle East, giving us a strong continental presence. You can be assured that wherever you are you can source a range of Expamet building products.

EXTENSIVE PRODUCT RANGE Expamet Building Products Limited is the parent company of a number of great brands – with each brand committed to quality in its particular product field.

Expamet Construction - One stop shop for metalwork for the construction industry BAT – Builders’ metalwork products Expamet – Plasterers’ accessories Hy-Rib® – Permanent formwork for concrete Power-Tie – Wall ties and ancillary fixings Expamet Express® – Our new next-day delivery service

Order before 1pm and we will despatch your order for next working day delivery, direct to branch or site. See www.expamet.co.uk for full details

TECHNICAL AND SALES SUPPORT Expamet provide a comprehensive pre and post-sales support service. From product advice and training through to design and implementation. Our sales and technical support teams have a wealth of construction and engineering experience and are available for both on and off-site support.

For more information call us on +44 (0)1429 866655.


Expamet operate a continuous development programme and we reserve the right to amend specification without prior notification. Please note, some products are not manufactured by Expamet and are therefore excluded from registration to BS EN 9001: 2008. Please contact the technical department for further information. All copyright, trade marks and unregistered design rights for the products detailed in this brochure are the property of Expamet Building Products Ltd.

EXPAMET BUILDING PRODUCTS LIMITED UK SALES AND DISTRIBUTION CENTRE Greatham Street, Longhill Industrial Estate (North), Hartlepool TS25 1PR England Tel: Sales: +44 (0)1429 866611 Sales Fax: +44 (0)1429 866622 E-mail: sales@expamet.net General: +44 (0)1429 866688 Fax: +44 (0)1429 866633 Technical: +44 (0)1429 866655 Tech E-mail: technical@expamet.net Website: www.expamet.co.uk IRISH SALES OFFICE DUBLIN: Unit 7, Swords Business Park, Swords, Co. Dublin Tel: +353 (0) 1890 2392 Fax: +353 (0) 1890 2220 E-mail: expamet@eircom.net

May 2011

Quality Assurance BS EN ISO 9001:2008 and ISO 14001 2004 Registered Firms Certificate No. FM36694, EMS 45225


Turn static files into dynamic content formats.