Grant Vortex oil range Internal and external oil-fired condensing boilers with outputs from 12kW to 70kW

and tanding h floor s t i w s e g r a n te e se ran ge r gua oiler hou n b a d h n c a x l e a t xtern he a Internal, e ive -year at ion • F 12-70kW • r e m p o r o f t s t e i u utp r qu models • O • W hi spe 39 different e f f ic ie nc y • l a e g u n n a r n a g n i 9 20 0 Award winn G ros s SA P 9.5 - 93.3% 8 • s n o i t p wa ll h u n g o


Grant profile

At Grant we have been designing and manufacturing reliable and easy to install heating products for over 35 years. From award winning oil-fired condensing boilers to the latest renewable technologies, our heating systems have a reputation for quality that is second to none. We combine precision engineering, innovation, performance and value for money to produce sustainable heating solutions that are trusted by both installers and householders.

Quality design

Heating responsibly

Our guarantee

There is never a compromise on quality. We design all of our products so that you can be sure that the durability and efficiency are sector leading. We continually develop new technologies and use only the best materials to ensure our products exceed all performance and environmental standards.

Grant manufacture heating systems that respond to the challenges of rising fuel costs whilst protecting our environment. Environmental responsibility is central to all we do and we continue to develop and innovate to produce even more efficient products that make best use of our natural resources.

The Grant label is a guarantee of reliability, quality and value. We put our customers first and our independence ensures that we can monitor our standards and processes to deliver the very best quality and service.

Our belief in simple solutions ensures that, while our technology is sophisticated, our products are low maintenance and easy to install. For a high quality, reliable and sustainable heating system, trust in Grant.

We are passionate about developing sustainable, high-performance and affordable alternatives for heating homes into the future.

02

That’s why, when you order your system from a Grant stockist, you can be sure of a tailored service and excellent aftersales support.


Oil condensing technology

What is a condensing boiler?

Award winning technology

Condensing boilers are designed to capture heat normally lost through the flue system during the combustion process.

Grant has become synonymous with highly efficient oilfired central heating appliances which help thousands of homeowners to reduce their annual fuel bills. Our ‘Multi Pass’ boiler achieves efficiency levels far in excess of any UK or European Standards while our Vortex oil-fired condensing boilers top the Government SEBUK Efficiency Database and are the market leading product in this sector.

Unlike traditional oil-fired boilers the Grant Vortex condensing boiler has a built-in stainless steel heat exchanger incorporating our unique turbulator baffle system which cools the gases to a point where the latent heat, normally lost to the atmosphere through the flue, can be usefully extracted. The additional energy recovered enables the boiler to operate continuously at much higher efficiency levels, resulting in lower heating and hot water running costs.

We have received numerous prestigious and high profile awards in recognition of our innovative product design, high quality engineering and exceptional training. • Product of the Year 2008 (Grant Vortex range) H&V News Awards for Excellence

• Which? Best Buy Accreditation 2008 (Grant Vortex Combi Pro 26)

The benefits of Grant Vortex While older oil-fired boilers operate with energy efficiency levels as low as 65%, modern boilers operate with much higher efficiency. The Grant Vortex range has the highest energy efficiency rating in the UK which not only significantly lowers fuel bills but also considerably reduces greenhouse gas emissions and lessens the environmental impact of domestic hot water and heating systems. All Grant Vortex boilers are easy to install and can either be connected to a conventional ‘stainless steel’ flue or one of Grant’s EZ-Fit flue options using an existing chimney.

01380 736920 | www.grantuk.com

• Training Initiative of the Year 2004 H&V News Awards for Excellence • OFTEC Training Centre of the Year 2012 Trusted by the trade and appreciated by our customers, the Grant Vortex range provides high efficiency, reduced fuel costs and unparalleled customer satisfaction.

03


Grant Vortex Eco Utility range

Introduction

Dimensions (mm)

The Grant Vortex Eco Utility range was launched as a direct response to customer demand for a competitively priced condensing boiler.

Grant Vortex Eco Utility 15-21 and 21-26

83 17

TRAP EXTERNAL DRAIN EXIT LEFT HAND

ø31

TRAP INTERNAL DRAIN EXIT LEFT HAND HIGH LEVEL

624

712

860

ø3 1

TRAP INTERNAL DRAIN EXIT LEFT HAND LOW LEVEL

88

177

As you would expect from a product with this pedigree, Grant Vortex Eco Utility boilers are exceptionally quiet in operation and feature the latest Riello burner technology. The boilers also have a simplified casing, control panel and pipework arrangement, making them the ideal choice for utility room installations.

445

Grant Vortex Eco Utility 26-35 60

ø3 8

587

719

19

TRAP EXTERNAL DRAIN EXIT LEFT HAND TRAP INTERNAL DRAIN EXIT LEFT HAND HIGH LEVEL TRAP INTERNAL DRAIN EXIT LEFT HAND LOW LEVEL

86 82

61 61

All standard Eco Utility boilers are designed to allow the burner and combustion chambers to be serviced from the front, however, models fitted with a sealed system kit require top service access.

605

28

860

The Eco models incorporate the latest version of the Grant Vortex stainless steel heat exchanger. Outputs range between 15kW and 35kW (50-120,000Btu/h) with SAP 2009 gross seasonal efficiencies of 90.3 - 90.8% gross.

430

441

Condensate removal The condensate trap is now factory fitted within the white case on Grant Vortex Eco Utility boilers, but can also be positioned externally if preferred.

Flueing Utility models are compatible with all of Grant’s EZ-Fit flue options and capable of being flued from the top, rear, left or right hand sides of the appliance.

Sealed system kits Grant Vortex Eco Utility models can also be converted to sealed system operation, by adding a sealed system kit (Product code: VTXECOSSKIT35). This optional pack fits all models and can be neatly housed within the boiler enclosure. It includes a filling loop, expansion vessel, pressure gauge and circulating pump.

04


SAP 2009 annual efficiency 90.3 - 90.8% gross

Grant Vortex Eco Utility models VTXECO1521 / VTXECO2126 / VTXECO2635 Boiler thermostat

Overheat thermostat

Boiler on/off switch

Multi-directional heating flow (not shown)

Front service access door

Multi-directional heating return (not shown)

Internal condensate trap (with external option)

Riello RDB burner

Model shown: VTXECO1521 (front view) Technical specifications Model

Vortex Eco wall-mounted programmer options

Eco Utility Models 15-21

21-26

26-35

Output kW

15 to 21

21 to 26

26 to 35

Output Btu/h

50-70,000

70-90,000

90-120,000

Flow connection

22mm

22mm

22mm

Return connection

22mm

22mm

22mm

Cold water in (system kit)

15mm

15mm

15mm

Pressure relief (system kit)

15mm

15mm

15mm

Weight (dry)

112kg

112kg

129kg

Condensate pipe

21.5mm OD plastic overflow pipe

Note 1: The boiler flow and return connections exit the casing on the left or right hand side. Note 2: Grant Vortex Eco Utility boilers are suitable for fully pumped systems only.

01380 736920 | www.grantuk.com

Optional Grant ES Kit, wall-mounted twin-channel programmer.

Optional Grant RS Kit wall-mounted programmable room thermostat.

05


Grant Vortex Eco External range

Introduction

Dimensions (mm)

Grant developed the first oil-fired external boiler in 1986 and although the concept was new to the oil market, it quickly became a popular addition to the range. Today, as around one in four oil boiler installations are external, Grant have expanded the number of options available with the launch of three competitively priced Eco External modules. The models have outputs between 15kW and 35kW (50-120,000Btu/h) and SAP 2009 gross seasonal efficiencies of 90.3 - 90.8% gross.

Grant Vortex Eco External 15-21, 21-26, 26-35

External finish This high efficiency Eco External range has some unique features including multi-directional flueing options, high quality external powder coated paint finish, built-in boiler frost protection, mains isolating switch and a test switch.

Sealed system kits Eco External boilers can be converted to sealed system operation by purchasing a pre-assembled kit from Grant UK (Product code: VTXECOSSKIT35). The sealed system kit includes an expansion vessel, automatic air vent, pressure relief valve and circulating pump. A filling loop and pressure gauge are also supplied as part of the kit. These can be fitted within the module casing, or ideally in a convenient site within the building, located between the cold main and central heating return.

Model shown: Grant Vortex Eco External module

06


SAP 2009 annual efficiency 90.3 - 90.8% gross

Grant Vortex Eco External modules VTXOMECO1521 / VTXOMECO2126 / VTXOMECO2635 Mains isolating switch Test switch

Boiler thermostat

Control panel

Overheat thermostat

Optional side or rear flue exits

Frost stat set to 5째C (factory fitted inside control panel not shown)

Optional pipe entry points

Riello RDB burner Condensate trap (factory-fitted in rear of casing - not shown)

Model shown: VTXOMECO1521 (front view) Technical specifications Model

Vortex Eco wall-mounted programmer options

Eco External modules 15-21

21-26

26-35

Output kW

15 to 21

21 to 26

26 to 35

Output Btu/h

50-70,000

70-90,000

90-120,000

Flow connection

22mm

22mm

22mm

Return connection

22mm

22mm

22mm

Cold water in (system kit)

15mm

15mm

15mm

Pressure relief (system kit)

15mm

15mm

15mm

Weight (dry)

127kg

117kg

143kg

Condensate pipe

21.5mm OD plastic overflow pipe

Note 1: All boiler connections can be positioned to the left or right of the appliance. Note 2: Grant Vortex Eco External modules are suitable for fully pumped systems only.

01380 736920 | www.grantuk.com

Optional Grant ES Kit, wall-mounted twin-channel programmer.

Optional Grant RS Kit wall-mounted programmable room thermostat.

07


Grant Vortex Eco Wall Hung range

Introduction

Dimensions (mm)

Grant’s wall hung oil-fired boiler range comprises four internal and four external models.

Grant Vortex Eco Wall Hung internal 12-16, 16-21

112

321.6

Available in outputs ranging from 12-21kW, in both sealed system and open-vented system variants, these new appliances are pre plumbed and encompass Grant’s patented Vortex stainless steel heat exchanger and turbulator baffle system.

221

112

580

840

All internal models require a separate flue kit (not supplied with the boiler) and are compatible with all Grant EZ-Fit low level, high level and vertical flue systems, so now almost any installation situation can be catered for.

Unique external modules All Grant Vortex Eco Wall Hung external models come complete with a factory fitted flue, high quality external powder coated paint finish, built-in boiler frost protection, mains isolating switch and a test switch.

321.

Grant Vortex Eco Wall Hung external 12-16, 16-21

Sealed system models

634.4

832.5

621

832.5 836.5

36.6

Grant Vortex Eco Wall Hung boilers are also available in sealed system versions. These include a factory fitted expansion vessel, filling loop, pressure gauge, automatic air vent, pressure relief valve and circulating pump, enabling boilers to be installed without the need for a feed and expansion tank in the loft.

349.8

08

621 629


SAP 2009 annual efficiency 91.6 - 91.9% gross

Grant Vortex Eco Wall Hung internal/ internal system models

Grant Vortex Eco Wall Hung external/ external system models

VTXWH1216 / VTXWH1621 / VTXSWH1216 / VTXSWH1621

VTXOMWH1216 / VTXOMWH1621 / VTXSOMWH1216 / VTXSOMWH1621 Multi-directional flue (Factory-fitted)

Multi-directional flue options (not supplied) see EZ flue kits

Pressure relief valve Automatic air vent

Expansion vessel

Pump

Internal condensate trap

Overheat thermostat Boiler on/off switch Remote lock-out indicator

Burner Removable control box Drain cock System pressure gauge

Pressure relief valve

Automatic air vent

Internal condensate trap

Pump

Removable control box Overheat thermostat

Boiler thermostat

Service switch Boiler on/off switch

Drain cock

Burner

Boiler thermostat

Model shown: VTXSWH1216 (front view)

Model shown: VTXSOMWH1216 (front view)

Technical specifications Model

Internal models 12-16

16-21

Internal system models

External modules

12-16

12-16

16-21

External system modules 16-21

12-16

Output kW

12 to 16

16 to 21

12 to 16

16 to 21

12 to 16

16 to 21

12 to 16

16 to 21

40-55,000

55-70,000

40-55,000

55-70,000

40-55,000

55-70,000

40-55,000

55-70,000

Flow connection

22mm

22mm

22mm

22mm

22mm

22mm

22mm

22mm

Return connection 22mm

22mm

22mm

22mm

22mm

22mm

22mm

22mm

Cold water in

n/a

15mm

15mm

n/a

n/a

15mm

15mm

Pressure relief

n/a

n/a

15mm

15mm

n/a

n/a

15mm

15mm

Weight (dry)

86kg

86kg

93kg

93kg

92kg

92kg

99kg

99kg

Condensate pipe

21.5mm OD plastic overflow pipe

Note 1: The boiler flow connection exits the casing on the top or bottom. Note 2: The return connection is located on the right and the condensate drain on the left.

01380 736920 | www.grantuk.com

Vortex Eco wall-mounted programmer options

16-21

Output Btu/h

n/a

System pressure gauge

Optional Grant ES Kit, wall-mounted twin-channel programmer.

Optional Grant RS Kit wall-mounted programmable room thermostat.

09


Grant Vortex Pro Kitchen/Utility range

Introduction

Dimensions (mm)

The Grant Vortex Pro Kitchen/Utility range has been upgraded to enable a number of new programmer options to be used with the appliance.

Grant Vortex Pro 15-21 Kitchen/Utility 566 L/H FLOW L/H RETURN

19

210 86

410

605 603

83

28

17

TRAP EXTERNAL DRAIN EXIT LEFT HAND

ø3 1

ø31

TRAP INTERNAL DRAIN EXIT LEFT HAND HIGH LEVEL

624

TRAP INTERNAL DRAIN EXIT LEFT HAND LOW LEVEL

88

177

860

There are nine models within the range covering outputs from 15-70kW (50,000-240,000 Btu/h), all of which feature Grant’s new internal condensate trap.

TRAP INTERNAL DRAIN EXIT LEFT HAND LOW LEVEL

Grant Vortex Pro 15-26 Kitchen/Utility and system

712

The boilers have very high SAP 2009 gross seasonal efficiencies of between 90.7 - 93.3% and feature the ‘award winning’ unique Grant Vortex stainless steel condensing heat exchanger, and turbulator baffle system. The 15-21 utility model has been designed to fit within a kitchen unit and, due to its reduced width, can be used as a direct replacement for most older oil-fired boilers.

TRAP INTERNAL DRAIN EXIT LEFT HAND HIGH LEVEL

594

A plug-in programmer (Product code: EPKIT) can be installed within the fascia, or alternatively, the receiver for Grant’s new wireless RFT Kit (Product code: RFTKIT) can be located within the knockout and the programmer sited conveniently within the building.

TRAP EXTERNAL DRAIN EXIT LEFT HAND

445

Sealed system models

Grant Vortex Pro 26-36 and 36-46 Kitchen/Utility and system

Sealed system variants of the Kitchen/Utility range are available in outputs of 15-26kW, 26-36kW and 36-46kW. Larger models above 46kW can also be converted to sealed system operation.

603

61

61

60

19

TRAP EXTERNAL DRAIN EXIT LEFT HAND

556

719

TRAP INTERNAL DRAIN EXIT LEFT HAND HIGH LEVEL

86 82

TRAP INTERNAL DRAIN EXIT LEFT HAND LOW LEVEL

441

Grant Vortex Pro 46-58 and 58-70 Kitchen/Utility

170

40 25

210

TRAP EXTERNAL DRAIN EXIT LEFT HAND

26

731

370 101

1024

831

Ø4 4

10

786 781

TRAP INTERNAL DRAIN EXIT LEFT HAND HIGH LEVEL

TRAP INTERNAL DRAIN EXIT LEFT HAND LOW LEVEL

620


SAP 2009 annual efficiency 90.7 - 93.3% gross

Grant Vortex Pro Kitchen/Utility models Grant Vortex Pro Kitchen/Utility sealed system models VTX1521 / VTX1526 / VTX2636 / VTX3646 / VTX4658 / VTX5870

VTXS1526 / VTXS2636 / VTXS3646 Boiler thermostat

Optional programmer position Boiler on/off switch

Optional programmer position

Boiler thermostat

System pressure gauge

Overheat thermostat

Overheat thermostat Boiler on/off switch

Internal condensate trap (with external option)

Internal condensate trap (with external option)

Riello RDB burner Riello RDB burner

Model shown: VTX1521 (front view)

Model shown: VTXS1526 (front view)

Technical specifications Model

Kitchen/Utility models 15-21

15-26

Kitchen/Utility system models 26-36

36-46

46-58

58-70

15-26S

46 to 58

58 to 70

15 to 26

Output kW

15 to 21

15 to 26

26 to 36

36 to 46

Output Btu/h

50-70,000

50-90,000

90-123,000

123-157,000 157-200,000 200-240,000 50-90,000

Flow connection

22mm

22mm

28mm

28mm

11/4” BSP

11/4” BSP

Return connection

22mm

22mm

28mm

28mm

11/4” BSP

Cold water in (system kit)

n/a

n/a

n/a

n/a

n/a

26-36S

36-46S

26 to 36

36 to 46

90-123,000

123-157,000

22mm

28mm

28mm

11/4” BSP

22mm

28mm

28mm

n/a

15mm

15mm

15mm

Pressure relief (system kit)

n/a

n/a

n/a

n/a

n/a

n/a

15mm

15mm

15mm

Weight (dry)

98kg

128kg

148kg

148kg

275kg

281kg

145kg

169kg

169kg

Condensate pipe

21.5mm OD plastic overflow pipe

Note 1: The boiler flow and return connections exit the casing on the left or right hand side. Note 2: Grant Vortex Pro Kitchen/Utility boilers are suitable for fully pumped systems only.

Vortex Pro Kitchen/Utility programmer options

Optional Grant EP Kit. Electronic twin-channel plug-in programmer.

Optional Grant RFT Kit. Wireless twin-channel programmable thermostat. Note: It is also possible to control Grant Vortex Pro Kitchen/Utility models with the optional twin channel programmer (ES Kit - see page 5).

01380 736920 | www.grantuk.com

11


Grant Vortex Pro External range

Introduction

Dimensions (mm)

The Grant Vortex Pro range of external modules encompass Grant’s original Vortex heat exchanger and have some of the highest efficiencies available today. The boilers are available in four outputs ranging between 15kW and 70kW (50-240,000 Btu/h).

Grant Vortex Pro External 15-21 943 385

637

517

879

788

879

187

307

Bespoke features

112

122 122

124

Grant Vortex Pro External 15-26 26-36 36-46

815

All Pro External modules enjoy the same unique features as the Eco External modules including the factory fitted multi-directional flue, high quality external powder coated casing, built in frost protection, mains isolating switch and a test switch. However, in addition, the boilers have a higher efficiency level and are factory wired to receive an ‘optional’ RF (radio frequency) wireless programmer. In this situation, the receiver can be plugged into the control panel of the module, enabling the boiler to be operated using a remote controller from any room inside the house, without the need for hard wiring.

734

248

Sealed system kits Grant Vortex Pro External 46-58 58-70 1154 945

587

179

418

816

1000

1154

1240

1240

233

1154

Grant Vortex Pro External condensing modules can be converted to sealed system operation by purchasing a pre-assembled kit from Grant UK. The sealed system kit includes an expansion vessel (size varies), automatic air vent, pressure relief valve and circulating pump. A filling loop and pressure gauge are also supplied as part of the kit. These can be fitted within the module casing, or ideally in a convenient site within the building, located between the cold main and central heating return.

191

191

Baffle arrangement Grant Vortex 26-36 External module

12

68

Optional side flue outlet


SAP 2009 annual efficiency 90.7 - 93.3% gross

Grant Vortex Pro External modules VTXOM1521 / VTXOM1526 / VTXOM2636 / VTXOM3646 / VTXOM4658 / VTXOM5870 Mains isolating switch Test switch

Boiler thermostat

Control panel

Overheat thermostat

Optional side flue exit

Frost stat set to 5°C (factory fitted inside control panel not shown)

Optional pipe entry points

Riello RDB burner Condensate trap (factory-fitted in rear of casing - not shown)

Model shown: VTXOM1526 (front view) Technical specifications - boiler connections

Vortex Pro External programmer options

Model

Pro External modules 15-21

15-26

26-36

36-46

46-58

58-70

Output kW

15 to 21

15 to 26

26 to 36

36 to 46

46 to 58

58 to 70

Output Btu/h

50-70,000

50-90,000

90-123,000

123-157,000

157-200,000

200-240,000 11/4” BSP

Flow connection

22mm

22mm

28mm

28mm

11/4” BSP

Return connection

22mm

22mm

28mm

28mm

11/4” BSP

11/4” BSP

Cold water in (system kit)

15mm

15mm

15mm

15mm

15mm

15mm

Pressure relief (system kit)

15mm

15mm

15mm

15mm

15mm

15mm

Weight (dry)

95kg

145kg

159kg

159kg

294kg

300kg

Condensate pipe

21.5mm OD plastic overflow pipe

Optional Grant RFT Kit. Wireless twin-channel programmable thermostat. Note: It is also possible to control Grant Vortex Pro External models with the optional twin channel programmer (ES Kit - see page 5).

Note 1: All boiler connections can be positioned to the left or right of the appliance. Note 2: Grant Vortex Condensing modules are suitable for fully pumped systems only.

01380 736920 | www.grantuk.com

13


Grant Vortex Pro Combi range

Introduction

Dimensions (mm)

For almost two years Grant has been working behind the scenes on brand new electronic versions of the successful Grant Vortex Combi range with the aim of incorporating as many of the additional features and benefits customers have requested, whilst bringing the technology installed in these appliances up to the minute.

Grant Vortex Pro Combi internal 21e and 26e

The models now include internal frost protection, neon diagnostic indicators and a factory fitted internal condensate trap (this can be sited externally if preferred), which is designed to make installation and servicing easier. The Grant Vortex Pro Electronic Condensing Combi’s are available as internal or external models in three sizes, 21kW, 26kW* and 36kW.

Grant Vortex Pro Combi internal 36e

Unique designs Grant Vortex Pro Combi features much larger heat exchangers which, due to their low water content and larger surface area, vastly increase the hot water performance available and mixing valves are pre-set at 50°C, controlling accurately the hot water draw off temperature from the boiler. They also feature a low system pressure cut off switch, enabling the combi to protect itself in the unlikely event of system water loss. Additionally, there are two very accurate electronic temperature controls which allow the boiler to operate in condensing mode on central heating, whilst maintaining its instant hot water production.

Grant Vortex Pro Combi external 21e, 26e and 36e 658

600

Typical hot water performance VTXCOMBI21* 15 litres per minute at an average temperature of 50°C. Recovery time 4 minutes approx. Based upon 100 litre draw off. VTXCOMBI26* 17 litres per minute at an average temperature of 50°C. Recovery time 4 minutes approx. Based upon 100 litre draw off. VTXCOMBI36* 20 litres per minute at an average temperature of 50°C. Recovery time 3 minutes approx. Based upon 100 litre draw off. Mains water pressure Minimum: 2.5bar (36psi). Maximum: 8bar (115psi). * Grant Vortex Pro Combi 26kW internal - Awarded ‘Which? Best Buy 2008’.

14

* Hot water flow rate is dependent on mains pressure available. Figures based upon an incoming mains water temperature of 10°C.


SAP 2009 annual efficiency 89.5 - 91.6% gross

Grant Vortex Pro Combi internal models Grant Vortex Pro Combi external modules VTXCOMBI21 / VTXCOMBI26 / VTXCOMBI36

VTXOMCOMBI21 / VTXOMCOMBI26 / VTXOMCOMBI36

Neon diagnostic indicators

Boiler on/off switch

Neon diagnostic indicators Electronic boiler thermostat

Optional timer kit position

System pressure gauge Overheat thermostat

Heating and hot water selector switches

Nickel plated pipes

Expansion vessel (size varies with model)

35 Plate heat exchanger

Internal condensate trap (with external option)

Thermostatic blending valve

Front service access

Boiler on/off switch

Overheat thermostat

Electrical isolation plug Service switch

Built-in system pressure gauge

Expansion vessel (size varies with model)

Nickel plated pipes Thermostatic blending valve Flexible filling loop

Flexible filling loop Pump (hot water circuit)

Riello RDB burner

Pump (hot water circuit) Riello RDB burner

Internal condensate trap (factory-fitted in rear of casing) not shown

Primary store drain cock

Model shown: VTXCOMBI26 (front view)

Model shown: VTXOMCOMBI26 (front view)

Technical specifications - boiler connections

Model Output kW

Electronic boiler thermostat

Pro Combi internal models

Pro Combi external modules

21

26

36

21

26

36

21

26

36

21

26

36

Output Btu/h

70,000

90,000

123,000

70,000

90,000

123,000

Flow connection

22mm

22mm

28mm

22mm

22mm

28mm

Return connection

22mm

22mm

28mm

22mm

22mm

28mm

Cold water in

15mm

15mm

22mm

15mm

15mm

22mm

Hot water out

15mm

15mm

22mm

15mm

15mm

22mm

Pressure relief

15mm

15mm

15mm

15mm

15mm

15mm

Weight (dry)

148kg

173kg

199kg

171kg

197kg

221kg

Condensate pipe

21.5mm OD plastic overflow pipe

Note 1: All boiler connections can be positioned to the left or right of the appliance. Note 2: Grant Vortex Pro internal and external condensing Combis are suitable for fully pumped systems only.

01380 736920 | www.grantuk.com

Vortex Pro Combi timer options

Optional Grant MT Kit. Single-channel mechanical timer.

Optional Grant RFT Kit. Wireless twin-channel programmable thermostat. Note: It is also possible to control Grant Vortex Pro Combi’s with the optional twin channel programmer (ES Kit - see page 5).

15


Grant Vortex Pro Boiler House range

Introduction

Dimensions (mm)

The new Grant Vortex Pro Boiler House models come as a blue cased unit with an externally mounted Riello RDB burner and thermostat.

Grant Vortex Pro Boiler House 26-36 and 36-46 460

191

These boilers are ideal for locations that are difficult to access like cellars or plant rooms, where a white cased utility version is not always the best solution.

The boilers encompass the same unique stainless steel heat exchangers used in other Vortex boilers together with Grant’s exclusive turbulator baffle system, which provides ultra-high efficiency and low running costs.

16

Flow

560

Grant Vortex Pro Boiler House 46-58 and 58-70 540

868 285

Stat

Model shown: Grant Vortex Pro 46-58kW Boiler House model installed in a cellar

835

Flow 1022

Grant Vortex Pro Boiler House models are compatible with all of Grant’s EZ-Fit flue options and are flued in exactly the same way as Kitchen/Utility models.

Stat

705

There are four models available with outputs of 26-36kW, 36-46kW, 46-58kW and 58-70kW. All have high SAP 2009 seasonal efficiencies between 90.7% and 93.3%.

600


SAP 2009 annual efficiency 90.7 - 93.3% gross

Grant Vortex Pro Boiler House models VTXBH2636 / VTXBH3646 / VTXBH4658 / VTXBH5870 Top flue exit

Heating return (under blanking plate) Dual stat (not shown) comes fitted on 46-58 and 58-70 models Heating flow (under blanking plate)

Condensate trap (Not shown)

Riello RDB burner

Model shown: VTXBH2636 (front view) Technical specifications - boiler connections Model

Vortex Pro Boiler House programmer options

Boiler House models 26-36

36-46

46-58

58-70

Output kW

26 to 36

36 to 46

46 to 58

58 to 70

Output Btu/h

90-123,000

123-157,000

157-200,000

200-240,000

Flow connection

28mm

28mm

11/4” BSP

11/4” BSP

Return connection

28mm

28mm

11/4” BSP

11/4” BSP

Cold water in (system kit)

n/a

n/a

n/a

n/a

Pressure relief (system kit)

n/a

n/a

n/a

n/a

Weight (dry)

122kg

122kg

229kg

236kg

Condensate pipe

21.5mm OD plastic overflow pipe

Note 1: The boiler flow and return connections exit the casing on the left or right hand side. Note 2: Grant Vortex Pro Boiler House boilers are suitable for fully pumped systems only.

Optional Grant EP Kit. Electronic twin-channel plug-in programmer.

Optional Grant RFT Kit. Wireless twin-channel programmable thermostat. Note: It is also possible to control Grant Vortex Boiler House models with the optional twin channel programmer (ES Kit - see page 5).

01380 736920 | www.grantuk.com

17


Compatible products

Introduction

EZ-Fit flue systems

Grant Vortex oil-fired boilers are one of the most efficient heating systems on the market. We also have other products in our wider range that work in conjunction with the Grant Vortex to deliver even more efficiency and cost savings as well as increasing the environmental credentials even further.

All Grant Vortex oil-fired boilers are supplied for connection to either a ‘stainless steel’ conventional flue, or one of Grant’s EZ-Fit flue options. The flue systems are available as low level, high level or vertical kits, for internal and external applications, and even as unique EZ-Flexi packs, designed to enable condensing boilers to utilise an existing chimney. All our EZ-Fit flues carry the CE mark of approval, are adaptable to any installation, and deliver excellent value for money.

Making your system even more environmental Combining a Grant oil-fired system with a renewable technology like Grant Solar Thermal is an excellent way to keep fuel costs down and to ensure your household is as energy efficient as possible. Solar Thermal systems are easy to install, and when combined with our oil-burning systems could provide up to 70% of your hot water needs, reducing your fuel costs and protecting the environment too.

18

To find out more about our environmentally responsible heating products, including biomass boilers, air source heat pumps, cylinders, thermal stores and control systems visit: www.grantuk.com or call us on: 01380 736920.


General information

Installation and commissioning

Standard Assessment Procedure (SAP)

Installation must comply with the current British Standards and The Building Regulations. Comprehensive technical information can be found in the installation manual, supplied with every boiler.

SEDBUK was developed by the Government alongside boiler manufacturers, under their ‘Energy Efficiency Best Practice Programme’. It was designed as a fair basis for comparisons of boiler energy performance when installed in a typical domestic situation in the UK.

As with all oil-fired appliances, Grant Vortex condensing boilers require commissioning at the time of installation. This simple process ensures that the boiler is working at peak efficiency which, in turn, will result in lower running costs and long term reliability.

Pluming Condensing boilers operate at extremely high efficiency levels, producing cool flue gas temperatures, resulting in a ‘plume’ of vapour being visible at the flue terminal. This plume (steam) is a normal condition of condensing boiler operation and indicates that the appliance is working efficiently.

To determine boiler efficiencies, a ‘Standard Assessment Procedure’ more commonly known as SAP, is used. SAP is the Government’s standard method for energy rating. SAP ratings enable the comparison of energy efficiencies and demonstrate the likely effect of improvements to a property in terms of energy use. Since SEDBUK was introduced in 1999, it has undergone many changes, the most recent being the move from SAP 2005 to SAP 2009. The changes focus on improving the accuracy of the way the efficiencies are worked out.

Low level balanced, high level, or vertical flue kits are available, which moves the plume to a higher level. Alternatively, it is possible to convert an existing low level balanced flue to an external high level or vertical arrangement using Grant’s Plume Diverter.

SAP 2009 incorporates a key revision in the assumed carbon emissions per kWh of oil used by the boiler. It may appear that the efficiencies of boilers have reduced with SAP 2009, but it is important to understand that the new methodology gives a more realistic estimate of the average annual boiler efficiency when installed in typical conditions, based on evidence from recent independent testing and field trials.

Guarantees

Fuel

The unique heat exchanger on Grant Vortex condensing boilers is covered by a 5-year guarantee. All other component parts of the boiler are guaranteed for 2 years from the date of purchase (excluding consumable items), subject to being installed in accordance with the manufacturers instructions. There are also optional annual, or 3-year extended warranty schemes available. On completion of the installation all Grant Vortex condensing boilers must be commissioned and the guarantee registration form completed online.

The burner on all Grant Vortex boilers is supplied factory set at the stated output for use on standard grade kerosene - Class C2. Grant Vortex condensing boilers manufactured from May 2011 onwards, however, will have a new ‘bio compatible’ burner fitted which is also suitable for biokerosene at a 30% blend, known as B30. To use B30 fuel, it will be necessary to change the oil feed line and ensure that other components used during installation e.g oil tank, etc. are suitable. Grant Vortex condensing boilers must not be used with Class D gas oil.

Aftersales service For peace of mind, all Grant central heating boilers are backed by a national network of independent service engineers. In the unlikely event of a problem occurring, your installer should telephone our Customer Service Department on: 01380 736920.

01380 736920 | www.grantuk.com

19


This leaflet is accurate at the time of printing but as Grant UK has a policy of continual improvement it may be superseded. We reserve the right to amend specifications without prior notice. The statutory rights of the consumer are not affected. All products manufactured under I.S. EN ISO 9001 and ISO 14001. ™The Grant ‘EZ-Fit flue’ system is a Trade Mark of Grant Engineering Limited. ®Grant Aerona, Grant Spira, Grant Vecta, Grant Vortex, Grant Solar, Grant Aurora, Grant Sahara, Grant CombiSOL, Grant WinterSOL, Grant MonoWave, Grant DuoWave, Grant ThermaWave, Euroflame and Multi Pass are registered trade marks of Grant Engineering Limited. The contents of this leaflet are fully protected by copyright and nothing may be reproduced without permission from Grant UK.

Grant Engineering (UK) Ltd Hopton House, Hopton Industrial Estate, Devizes, Wiltshire, SN10 2EU T: 01380 736920 F: 01380 736991 E: sales@grantuk.com W: www.grantuk.com

VCB 06/13 UK

GRANT

EZ FIT

™ FLUE SYSTEM


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.