Product Guide Specialist supplier of construction solutions
www.rom.co.uk
Dowel bars cages Page 29 Dowel bars Page 28 Dowel bars sleeves Page 28 Plastic spacers Page 19/20 D-BOND Page 28 Filler board Page 29
Prefabricated pilecaps Page 11 Prefabricated piles Page 11
2
Steel kickers Page 24 Startabox Page 14/15 Concrete spacers Page 21/22 Plastic spacers Page 19/20 Wire spacers Page 22
Flying end fabric Page 7 Readyfit fabric Page 8 Kwikfix fabric Page 9/10 Prefabricated mats Page 11 Dekchairs Page 22 Plastic spacers Page 19/20 Concrete spacers Page 21/22 Wire spacers Page 22
Flying end fabric Page 7 Ready fit fabric Page 8 Prefabricated mesh Page 11 Kwikfix fabric Page 9/10 Plastic spacers Page 19/20 Concrete spacers Page 21/22 Damp proof membrane Page 26 Wire spacers Page 22 Beamform Page 16/17 Clayshield Page 16/17 Castellated clayshield Page 16/17 Grippa plastic spacers Page 16/17 Prefabricated beam cages Page 11
Reinforcement Shape Codes Weights and Area’s of Reinforcement Standard Fabric Chart Flying End Fabric Readyfit Fabric Kwikfix Fabric Kwikfix+ Fabric Prefabrication
Shear ladders Page 18
Couplers Lenton / Ancon / MBT Couplers
Startabox
12-13
®
The Startabox System
Prefabricated Columns Page 11 Couplers Page 12/13 Plastic Spacers Page 19/20 Concrete Spacers Page 21/22
4 5 6 7 8 9 10 11
14-15
Beamform Dowel bar cages Page 29 Dowel bars Page 28 Dowel bar end caps Page 28 D-BOND Page 28 Filler board Page 29 Rom Tape Page 26 Damp proof membrane Page 26
ROM Beamform
16-17
Sheer Ladders The ROM Shear Ladder System
18
Spacers Plastic / Concrete / Wire Spacers
19-22
Formwork Accessories Formwork Accessories
23-24
Accessories Accessories
25-31
Chemicals Formwork Chemicals, Fillers & Tapes 32-33
Additional Information Depot Locations ROMTECH Index Terms and Conditions Health and Safety Holding down bolts, Conical bolt boxes & Grout Page 25
34-35 36-37 38 39 40
3
Shape Codes
to BS8666: 2005
Shape Codes
Shape Codes
to BS8666: 2005
to BS8666: 2005
Shape Code
Total length of bar (L) measured along centre line
Shape Code
Total length of bar (L) measured along centre line
Shape Code
Total length of bar (L) measured along centre line
Shape Code
Total length of bar (L) measured along centre line
00
A
24
A+B+(C)
34
A + B + C + (E) – 0.5r - d
63
2A + 3B + 2(C) - 3r - 6d (C) and (D) shall be equal and not more than A or B nor less than P for links in Table 2. Where (C) and (D) are to be minimized the following formula may be used: L = 2 A + 3B + max(14d, 150)
A and (C) are at 90O to one another
Neither A nor (E) shall be less than P in Table 2. See note 1
11
A+(B)-0.5r-d
25
A + B + (E)
A+(B)-0.43R-1.2d
26
A + B + (C)
Neither A nor B shall be less than (R + 6d)
13
A + 0.57B + (C) - 1.6d
64
A+B+C+2D+E+(F)-3r-6d
Neither A nor B shall be less than P in Table 2. If E is the critical dimension, schedule a 99 and specify A or B as the free dimension. See note 1.
Neither A nor B shall be less than P in Table 2
12
35
A+B+C+(E)-0.5r-d
Neither A nor (F) shall be less than P in Table 2. See note 2
36
than P in Table 2. See note 1.
A + B + (C) – 0.5r-d
B shall not be less than 2(r + d). Neither A nor C shall be less than P in Table 3 nor less than (0.5B + 5d). See Note 3.
67
41
A + B + C + D + (E) - 2r - 4d
than P in Table 2. See note 1.
75
/
A+(C)
28
A+B+(C)-0.5r-d
44
A + B + C + D + (E) - 2r - 4d
77
/ (A-d) + B Where B is greater than A/5 this equation no longer applies, in which case the following formula may be used: L = C ((/ (A-d))2 + B2)1/2
Neither A nor (E) shall be less
29
A+B+(C)-r-2d
46
Neither A nor (C) shall be less than P in Table 2. See note 1.
21
A + B + (C) – r – 2d
31
A+B+C+(D)-1.5r-3d
47
than P in Table 3
than P in Table 2
23
A + B + C + (D) - 1.5r - 3d C shall not be less than 2(r + d). Neither A nor (D) shall be less than P in Table 2. Where used as a link, A shall not be less than P for links in Table 2 and (D) shall not be less than C/2 + 5d
32
A + B + (C) – r – 2d
33
A+B+C+(D)-1.5r-3d
2A + 1.7B + 2C - 4d
Neither A nor (C) shall be less than P in Table 2 Key: 1 - Semi-circular
4
www.rom.co.uk
98
A shall not be less than 12d + 30mm. B shall not be less than 2(r + d). C shall not be less than P in Table 2, nor less than B/2 + 5d. See Note 3.
51
56
2A + B + 2C +1.5r - 3d (C) and (D) shall be equal and not more than A nor less than P in Table 2. Where (C) and (D) are to be minimized the following formula may be used: L = 2A + B + max(21d, 240) 2 (A + B + (C)) - 2.5r - 5d (C) and (D) shall be equal and not more than A or B nor less than P for links in Table 2. Where (C) and (D) are to be minimized the following formula may be used: L = 2A + 2B + max(16d, 160) A+B+C+(D)+12d
Neither C nor (D) shall be less than P in Table 2
All other shapes where standard shapes cannot be used.
To be calculated
No other shape code number, form of designation or abbreviation shall be used in scheduling. A dimensional sketch shall be drawn over the dimension columns A to E. Every dimension shall be specified and the dimension that is to allow for permissible deviations shall be indicated in parenthesis, otherwise the fabricator is free to choose which dimensions shall allow for tolerance.
Grade B500A, Grade B500B or Grade B500C conforming to BS4449:2004
H
Grade B500A conforming to BS4449:2004
A
Grade 500B or Grade B500C conforming to BS4449:2004
B
Grade 500C conforming to BS4449:2004
C
A specified grade and type of ribbed stainless steel conforming to BS 6744:2001
S
Reinforcement of a type not included in the above list having material properties that are defined in the design or contract specification.
X
NOTE 1 Due to ‘spring back’ the actual radius of the bend will be slightly greater than half the diameter of the former.
Fig. 4
Example of bar with more than one bend
Isometric sketch.
99
Notation
Table 2 Minimum Schedule Radius and Bend Allowances
Dimensioning of cranked bars
A+2B+C+(D)-2r-4d
than P in Table 2. See note 1
Neither A nor (C) shall be less
Key: 1 - Semi-circular
A + 2B + C + (E) Neither A nor (E) shall be less
Neither A nor (D) shall be less
22
NOTE 3 For shapes with straight and curved lengths (e.g. shape codes 12, 13, 22, 23 and 47) the largest practical mandrel size for the production of a continuous curve is 400mm. See also Clause 10.
Where B is the overlap
than P in Table 2 A + (C)
NOTE 2 Five bends or more might be impractical within permitted tolerances.
Fig. 5
Neither A nor (C) shall be less than P in Table 2. See note 1
15
NOTE 1 The length equations for shape codes 14, 15, 25, 26, 27, 34, 36, and 46 are approximate and where the bend angle is greater than 45º, the length should be calculated more accurately allowing for the difference between the specified overall dimensions and the true length measured along the central axis of the bar. When the bending angles approach 90º, it is preferable to specify shape code 99 with a fully dimensional sketch.
Type of steel reinforcement
(A-d)+B
Key: 1 - Semi-circular
14
Figures 4, 5 and 6 should be used in the interpretation of bending dimensions.
Notation of steel reinforcement
NOTE In the Grade description B500A etc, ‘B’ indicates reinforcing steel.
See Clause 10
Neither A nor (E) shall be less than P in Table 2. May also be used for flag link viz:
Neither A nor (C) shall be less
The length of straight between two bends shall be at least 4d, see figure 6.
A
Neither A nor (D) shall be less than P in Table 2. See note 1
Neither A nor (C) shall be less
27
A+B+C+(D)-r-2d
(Continued)
Fig. 6
Nominal Bar Size d
Maximum Radius for Scheduling r
Minimum end projection,P Minimum General Links Diameter of where Bending Former, (min 5d straight bend<150˚
6mm
12mm
24mm
110mm
110mm
8mm
16mm
32mm
115mm
115mm
10mm
20mm
40mm
120mm
130mm
12mm
24mm
48mm
125mm
160mm
16mm
32mm
64mm
130mm
210mm
20mm
70mm
140mm
190mm
290mm
25mm
87mm
175mm
240mm
365mm
32mm
112mm
224mm
305mm
465mm
40mm
140mm
280mm
380mm
580mm
Tolerances on cutting and bending dimensions
Radius of bending
The tolerances for cutting and/or bending dimensions shall be in accordance with Table 5 and shall be taken into account when completing the schedule. The end anchorage or the dimension in parentheses in the shape codes specified in Table 3 shall be used to allow for any permissible deviations resulting from cutting and bending.
Reinforcement to be formed to a radius exceeding that specified in Table 5 shall be supplied straight.
Table 5 Tolerances See Note 2.
The values for minimum radius and end projection, r and P respectively, as specified in Table 2, shall apply to all shape codes (see 7.6). The dimensions in parenthesis are the free dimensions. If a shape given in this table is required but a different dimension is to allow for the possible deviations, the shape shall be drawn out and given the shape code 99 and the free dimension shall be indicated in parenthesis. (Continued on following page)
Cutting and bending processes
Tolerance (mm)
Cutting of straight lengths (including reinforcement for subsequent bending)
+ 25, -25
Bending: ) 1 000 mm > 1 000 mm to ) 2 000 mm > 2 000 mm Length of bars in fabric
+5, -5 +5, - 10 +5, - 25 25 or 0.5% of the length (whichever is greater)
Table 6 Maximum limit for which a preformed radius is required Bar Size 6mm 8mm 10mm 12mm 16mm 20mm 25mm 32mm 40mm
Radius 2.5M 2.75M 3.5M 4.25M 7.5M 14.0M 30.0M 43.0M 58.0M
NOTE 1 The required curvature may be obtained during placing. NOTE 2 For shapes with straight and curved lengths (e.g. shape code 12, 13, 22 and 33) the largest practical radius for the production of a continuous curve is 200 mm, and for larger radii the curve may be produced by a series of short straight sections
For details of your local depot, please turn to pages 34-35 Web: www.rom.co.uk
For details of your local depot, please turn to pages 34-35 Web: www.rom.co.uk
Email: (Engineering Services) - engineering@rom.co.uk (Sales) - sales@rom.co.uk
Email: (Engineering Services) - engineering@rom.co.uk (Sales) - sales@rom.co.uk
Reinforcement Charts
Weights and Areaâ&#x20AC;&#x2122;s of Reinforcement
Cross-sectional Areas of Groups of Bars (mm2) Bar Size
Number of Bars 1
6mm* 8mm 10mm 12mm 16mm 20mm 25mm 32mm 40mm 50mm*
28.3 50.3 78.5 113.1 201.1 314.2 490.9 804.2 1257.0 1963.5
*Denotes non-preferred sizes
2
3
56.5 100 157 226 402 628 982 1608 2513 3927
84.8 151 236 339 603 942 1473 2413 3770 5890
4 113 201 314 452 804 1257 1963 3217 5026 7854
5 141 251 339 566 1005 1571 2454 4021 6283 9812
6
7
170 302 471 679 1206 1885 2945 4825 7540 11781
198 352 550 792 1407 2199 3436 5630 8790 13744
8
9
226 402 628 905 1608 2513 3927 6434 10053 15708
255 452 707 1718 1810 2827 4418 7238 11310 17671
10 283 503 785 1131 2011 3142 4909 8042 12566 19635
Cross-sectional Areas for Specific Spacings in mm2/ Metre Width Bar Size
6mm* 8mm 10mm 12mm 16mm 20mm 25mm 32mm 40mm 50mm*
Spacing of Bars (millimetres)
*Denotes non-preferred sizes
75
100
125
150
377 670 1047 1508 2681 4189 6545 -
283 503 786 1131 2011 3142 4909 8042 -
226 402 628 905 1608 2513 3927 6434 10053 -
188 335 524 754 1340 2094 3272 5362 8378 13090
175
200
225
250
162 287 449 646 1149 1795 2805 4596 7181 11220
141 251 393 565 1005 1571 2454 4021 6283 9617
125 223 348 503 894 1396 2182 3574 5587 8727
113 201 314 452 801 1257 1963 3217 5027 7854
275
300
103 183 285 411 731 1143 1785 2924 4571 7140
94 168 262 377 670 1047 1636 2681 4189 6545
Weights for Groups of Bars (kg/metre run Bar Size 6mm * 8mm 10mm 12mm 16mm 20mm 25mm 32mm 40mm 50mm*
Number of bars
*Denotes non-preferred sizes
1
2
3
4
5
6
7
8
9
10
0.222 0.395 0.616 0.888 1.579 2.466 3.854 6.313 9.864 15.413
0.444 0.79 1.232 1.776 3.158 4.932 7.708 12.626 19.728 30.826
0.666 1.185 1.848 2.664 4.737 7.398 11.562 18.939 29.592 46.239
0.888 1.58 2.464 3.552 6.316 9.864 15.416 25.252 39.456 61.652
1.11 1.975 3.08 4.44 7.895 12.33 19.27 31.565 49.32 77.065
1.332 2.37 3.696 5.328 9.474 14.796 23.124 37.878 59.184 92.478
1.554 2.765 4.312 6.216 11.053 17.262 26.97 44.191 69.048 107.891
1.776 3.16 4.928 7.104 12.632 19.728 30.832 50.504 78.912 123.304
1.998 3.555 5.544 7.992 14.211 22.194 34.686 56.817 88.776 138.717
2.22 3.95 6.16 8.88 15.79 24.66 38.54 63.13 98.64 154.13
Weight per M2 in one direction (Add both directions for total M2 weight) Bar Size
6mm* 8mm 10mm 12mm 16mm 20mm 25mm 32mm 40mm 50mm*
Spacing of Bars (millimetres)
*Denotes non-preferred sizes
75
100
125
150
175
200
225
250
275
300
2.960 5.267 8.213 11.840 21.050 32.880 51.390 -
2.220 3.950 6.160 8.880 15.790 24.660 38.540 63.130 -
1.776 3.160 4.928 7.104 12.630 19.730 30.830 50.500 78.910 -
1.480 2.633 4.107 5.920 10.530 16.440 25.690 42.090 65.760 102.750
1.269 2.257 3.520 5.074 9.023 14.090 22.020 36.070 56.370 88.070
1.110 1.975 3.080 4.440 7.895 12.331 19.270 31.570 49.320 77.060
0.987 1.756 2.738 3.947 7.018 10.960 17.128 28.058 43.840 68.502
0.888 1.580 2.464 3.552 6.316 9.864 15.420 25.250 39.460 61.650
0.807 1.436 2.240 3.229 5.742 8.967 14.015 22.956 35.869 56.047
0.740 1.317 2.053 2.960 5.262 8.220 12.850 21.040 32.880 51.380
For details of your local depot, please turn to pages 34-35 Web: www.rom.co.uk Email: (Engineering Services) - engineering@rom.co.uk (Sales) - sales@rom.co.uk
5
Reinforcement
Standard Fabric
Standard Sizes (4800mm x 2400mm) Cross Sectional Area per Metre Width
Nominal Weight per M2
Cross
Main
Cross
10mm
10mm
393mm2
200mm
8mm
8mm
200mm
7mm
7mm
200mm
200mm
6mm
200mm
200mm
B 1131
100mm
B 785
Mesh Size Nominal Pitch of Wires
Wire Sizes
Main
Cross
Main
A 393
200mm
200mm
A 252
200mm
A 193
200mm
A 142 A98
(Kg)
Sheets per tonne (approx)
Sheet Weight (kg)
Sheets per Bundle
Square Metres per tonne
393mm2
6.16
15
70.96
18
162.34
252mm
2
252mm
3.95
22
45.50
28
253.16
193mm2
193mm2
3.02
29
34.79
34
331.13
6mm
142mm
142mm
2.22
40
25.57
46
450.45
5mm
5mm
98mm
98mm
1.54
57
17.74
60
649.35
200mm
12mm
8mm
1131mm2
252mm2
10.90
8
125.57
10
91.74
100mm
200mm
10mm
8mm
785mm
252mm
8.14
11
93.57
14
122.85
B 503
100mm
200mm
8mm
8mm
503mm
252mm
B 385
100mm
200mm
7mm
7mm
B 283
100mm
200mm
6mm
7mm
B196
100mm
200mm
5mm
C 785
100mm
400mm
C 636
100mm
C 503
BS Reference SQUARE
2
2
2
2
2
STRUCTURAL
2
2
5.93
15
68.31
18
168.63
385mm
2
193mm
4.53
20
52.19
24
220.75
283mm2
193mm2
3.73
24
42.97
30
268.10
7mm
196mm
193mm
3.05
29
35.14
36
327.87
10mm
6mm
785mm2
70.8mm2
6.72
13
77.41
16
148.81
400mm
9mm
6mm
636mm2
70.8mm2
5.55
16
63.94
20
180.18
100mm
400mm
8mm
5mm
503mm
49.0mm
4.34
20
50.00
26
230.41
C 385
100mm
400mm
7mm
5mm
385mm
49.0mm
3.41
26
39.28
30
293.26
C 283
100mm
400mm
6mm
5mm
283mm
2
49.0mm
2.61
34
30.07
32
383.14
100mm
100mm
2.5mm
2.5mm
49.1mm2
49.1mm2
0.77
129
7.76
50
1298.70
Sheet Weight (kg)
Sheets per Bundle
Square Metres per tonne
2
2
2
2
2
LONG
2
2
2
2
2
WRAPPING D49
Merchant Sizes (3600mm x 2000mm) Mesh Size Nominal Pitch of Wires
Wire Sizes
Main
Cross
Main
A 393M
200mm
200mm
A 252M
200mm
A 193M A 142M
BS Reference
B 785M
6
Cross Sectional Area per Metre Width
Nominal Weight per M2
Cross
Main
Cross
(Kg)
Sheets per tonne (approx)
10mm
10mm
393mm2
393mm2
6.16
23
44.35
26
162.34
200mm
8mm
8mm
252mm
252mm2
3.95
35
28.44
30
253.16
200mm
200mm
7mm
7mm
2
193mm
2
193mm
3.02
46
21.74
50
331.31
200mm
200mm
6mm
6mm
142mm
2
142mm
2
2.22
63
15.98
50
450.45
200mm
10mm
8mm
785mm2
252mm2
8.14
17
58.61
20
122.85
100mm
www.rom.co.uk
2
Reinforcement
Flying End Fabric
Don’t compromise on cover Fabric without the overlap congestion
To BS 4483 Type 2 Wire Profile in both ‘A & B’ Types
Standard Fabric Congestion at Laps
x
Flying End Fabrics Nested Lap
Even when staggering laps, you cannot avoid at least a 3 layer build up.
No congestion, even where 4 sheets meet.
Available in Types: All with splices to enable minimum lapping 40 x bar dia.
‘A’ Range
‘B’ Range
A393
B1131
A252
B785
Particularly beneficial:
A193
B503
A142
B385
• Where standard fabric is specified as a structural reinforcement. • In thin topping slabs on permanent metal & precast decking
Also available in a T12 on T12 format
For details of your local depot, please turn to pages 34-35 Web: www.rom.co.uk Email: (Engineering Services) - engineering@rom.co.uk (Sales) - sales@rom.co.uk
7
Reinforcement
Readyfit Fabric
Whatever the size
Fabric to save you time and money
Length up to 8.0M Width 1.8 to 3.2M
For the larger mat To BS4483 - with Type 2 wire profile in all ‘A’, ‘B’ & ‘C’ types.
Length up to 6.0M Width 0.3 to 1.8M
For the smaller mat
• Length & width made to suit your exact needs • Beneficial in repetitive pre-cast applications • Economical in slab long strip construction • Manufactured with flying ends if required • Reverse ‘B’ type fabrics also available
(ie cross wires @ 100crs & long wires @ 200crs)
• Technical support available
8
www.rom.co.uk
Reinforcement Kwikfix Fabric
Is time of the essence?
A quick approach to rebar detailing & placement
Two way One way
The one-way fabric that gives you a two-way solution
Lacer bars @ 1000crs approx.
Width 1.5 to 3.2M
BS4483 Type 2 wire profile
Length up to 8.0M
Manufactured in T8, T10, T12, T14 & T16 @ preferred 100, 150 & 200cts. (Overall sheet size dependant on bar diameter & crs. to suit handleability).
• Fast & Cost efffective method of placing reinforcement
For nesting end laps, splice lengths are of at least 40 x bar dia. No requirement for side lapping ie: butt sheets together
Flexability for Detailer
Flexability for Fixer
• No craneage for final placement • Man-handleable sheets • Very little tying required • Accurate location of bars • Fabric detailing service
For those who prefer staggered end laps
If required additional rebar can be easily added on site
For details of your local depot, please turn to pages 34-35 Web: www.rom.co.uk Email: (Engineering Services) - engineering@rom.co.uk (Sales) - sales@rom.co.uk
9
Reinforcement Kwikfix+ Fabric
Flexibility Holds the Key
Single & Two Directional Fabrics for specific requirements
* All to BS4483 in type 2 wire
Single Directional
• Main Steel in T8, T10, T12, T14 & T16
Width 1.5 to 3.2M
• Alternate bar diameter mix (either next dia. up or down)
Fabrication wires only
• Variable centres to suit required area of Steel (100mm min) Length up to 8.0M
• Staggered bars re: Lapping & Curtailment • Place like loose bar in B1, B2, T2 & T1 layers • End Splices means no congestion at laps
Main Steel
• Ideal when detailing two way spanning structural slabs
* Two Efficient Methods of Detailing & Placing Reinforcement
Two Directional
• Main steel in T8, T10, T12, T14 & T16 • Distribution in steel in T8, T10 & T12
Width 1.5 to 3.2M
• Alternate bar diameter mix (main steel only)
Distribution Steel
Length up to 8.0M
Main Steel
• Variable centres to suit required area of steel (for both main & distribution bars) • Variable alternate bar lengths (main steel only) • End & side splices means no congestion at laps • Ideal when detailing one way spanning structural slabs.
*Contact ROM Design team for detailing ideas
10
www.rom.co.uk
Reinforcement Prefabrication
ROM Prefabrication Service
ROM offer's a complete offsite reinforcement prefabrication service that produces finished cage or mat assemblies delivered, ready for placing in position on site. The prefabricated units are designed by ROM in conjunction with the customer to ensure compatibility on site. Assemblies can be Mig welded or wire tied with additional reinforcement if required to ensure that the integrity of the assembly is maintained during transportation and placing on site.
Quality Assurance All ROM prefabrication facilities, materials and welder's are fully CARES approved. Our facilities, materials and operatives are independantly audited on a regular basis to ensure the correct procedures are complied with.
Key Benefits
• •
Removes steel fixing from the critical path.
•
Costly site fixing becomes cost effective placing of prefabricated units.
•
Improved safety from reductions in movement of loose bar.
•
Assemblies supplied with labels and location plan for ease of identification.
Continuity of manufacture regardless of weather conditions.
Typical Items from ROM Ground beams, pile caps, piles, diaphragm wall cages, columns, beams, heavy diameter one way / two way mats etc. ROM would welcome the opportunity to discuss your requirements. For details of your local depot, please turn to pages 34-35.
For details of your local depot, please turn to pages 34-35 Web: www.rom.co.uk Email: (Engineering Services) - engineering@rom.co.uk (Sales) - sales@rom.co.uk
11
Reinforcement Connection
Lenton Couplers
Threading Charge (E/O Per Thread)
Product Line The most widely used mechanical splicing system in the world. With experience of over 30 years, LENTON® products provide a complete line of full tension and compression mechanical splices. LENTON® couplers are the slimmest couplers on the market for tension and compression.
Couplers - A12
LENTON® standard couplers are designed to splice the the same diameter bars where one bar can be rotated and is not restricted in its axial direction.
Position Couplers - P14 Price Each
Product Code
To suit bar Diameter
Pack Size
12 P14
12mm
1
£15.82
16 P14
16mm
1
£18.40
20 P14
20mm
1
£20.18
25 P14
25mm
1
£23.39
32 P14
32mm
1
£31.39
40 P14
40mm
1
£47.67
50 P14
50mm
1
£78.74
Transition Couplers - R11
12mm 16mm 20mm 25mm 32mm 40mm 50mm
£1.73 £1.97 £2.30 £2.61 £3.64 £4.48 £ POA
Standard Couplers - A12 Product Code
To suit bar Diameter
Pack Size
Price Each
12 A12
12mm
1
£2.63
16 A12
16mm
1
£3.40
20 A12
20mm
1
£6.07
25 A12
25mm
1
£9.49
32 A12
32mm
1
£12.92
40 A12
40mm
1
£18.75
50 A12
50mm
1
£28.08
The Positional style coupler P14 can Position be used when neither bar can be Couplers - P14 rotated and when the ongoing bar is free to move in its axial direction. If the ongoing bar is restricted in its axial direction then a P13 type coupler is required. Contact your nearest ROM depot for detailed information.
Transition couplers are designed to splice different diameter bars where one bar can be rotated and is not restricted in its axial direction
Transition Couplers - R11 Product Code
To suit bar Diameter
Pack Size
Price Each
12/16R11
12/16mm
1
£POA
16/20R11
16/20mm
1
£POA
20/25R11
20/25mm
1
£POA
25/32R11
25/32mm
1
£POA
32/40R11
32/40mm
1
£POA
40/50R11
40/50mm
1
£POA
For a full range of couplers please contact your local depot, please turn to pages 34-35.
12
www.rom.co.uk
Reinforcement Connection Ancon Couplers
The benefits of using reinforcing bar couplers to accelerate the speed of construction, increase productivity and simplify the design of reinforced concrete are widely recognised. The Ancon range includes tapered, threaded and mechanically bolted couplers.
Tapered Thread Standard
Ancon Tapered Thread Standard couplers are designed to suit the majority of applications which call for the joining of reinforcing bars. The couplers are normally supplied fitted to the end of threaded bar, requiring only the engagement and tightening of the adjoining bar on site. Ancon specifies the use of a torque wrench in order to achieve correct and consistent installation.
Tapered Thread Positional Product Code
Bar Diameter
TTP12 TTP16 TTP20 TTP25 TTP32 TTP40 TTP50
12mm 16mm 20mm 25mm 32mm 40mm 50mm
Coupler Price £POA £POA £POA £POA £POA £POA £POA
Tapered Thread Transition
Product Code
To suit bar Diameter
Pack Size
Price per Pack
RC2025 RC2525 RC3025 RC3525 RC4025 RC5025
16mm to 25mm 8mm to 25mm 8mm to 25mm 8mm to 25mm 8mm to 25mm 8mm to 25mm
1000 500 500 500 500 500
£48.54 £26.47 £27.39 £29.52 £28.64 £37.04
12mm 16mm 20mm 25mm
£POA £POA £POA £POA
32mm 40mm 50mm
£POA £POA £POA
Tapered Thread Standard Product Code
Bar Diameter
TTS12 TTS16 TTS20 TTS25 TTS32 TTS40 TTS50
12mm 16mm 20mm 25mm 32mm 40mm 50mm
The Ancon Tapered Thread Positional coupler is designed to be used in applications in which neither bar can be rotated. Having a degree of adjustability, the Positional coupler can also be used as a closer between two fixed bars. The couplers are normally supplied fitted to the end of threaded bar, requiring only the engagement and tightening of the adjoining bar on site. In order to ensure correct and consistent installation, Ancon Building Products specifies the use of a torque wrench.
The Ancon Tapered Thread Transition coupler connects reinforcing bars of different diameters. The coupler comprises an internally threaded sleeve with two right hand threads both of which are tapered towards the middle of the coupler. The diameter of each thread corresponds to the appropriate bar size. The couplers are normally supplied fitted to the end of threaded bar, requiring only the engagement and tightening of the adjoining bar on site. In order to ensure correct and consistent installation, Ancon Building Products specifies the use of a torque wrench.
MBT Coupler
Threading Charge (E/O Per Thread)
Coupler Price £POA £POA £POA £POA £POA £POA £POA
Tapered Thread Positional
Tapered Thread Transition Product Code TTT12/16 TTT16/20 TTT20/25 TTT25/32 TTT32/40 TTT40/50
To suit bar Diameter 12mm/16mm 16mm/20mm 20mm/25mm 25mm/32mm 32mm/40mm 40mm/50mm
Coupler Price £POA £POA £POA £POA £POA £POA
MBT Coupler The MBT ET Series of couplers provides an effective method of joining reinforcing bars which requires neither bar end preparation to form threads, nor bar rotation. They can be used to connect onto insitu bars and will join imperial, plain round or deformed reinforcing bars.
For a full range of couplers please contact your local depot, please turn to page 34-35. For details of your local depot, please turn to pages 34-35 Web: www.rom.co.uk Email: (Engineering Services) - engineering@rom.co.uk (Sales) - sales@rom.co.uk
13
Reinforcement Connection
The Startabox System ®
The Startabox® System is a quick and safe way of achieving high quality reinforcement connections in a structural concrete joint without formwork damage. It consists of specially selected high yield reinforcement steel conforming to BS4449 housed in a perforated case with a tear-off plastic cover which protects the reinforcement until it is required for use.
Speed Startabox® is quickly nailed into the formwork. There is no need for time-consuming drilling and cutting of the formwork. The formwork can be easily struck and re-erected thereby reducing intervals between pours. Safe The steel starter bars are housed within their case until ready for use. There are no protruding bars which may corrode or become damaged and present a hazard to workmen. Cost The formwork suffers no damage and therefore may be re-used many times. This contrasts with normal stop-ends which only offer one use.
Quality Traditional stop-ends offer suffer grout loss. Startabox
is nailed to plain formwork and does not suffer the same problem. This means that Startabox will deliver a high quality construction joint every time. ®
®
Site ‘Take off’ and scheduling service available
Case Sizes
N.B. The Type 11 case with 16mm bars is produced with single bars only. Cases containing 8,10 and 12mm bars supplied 30mm deep. Cases containing 16mm bar supplied 50mm deep with steel lids for greater rigidity.
Re-bending tools available from stock. 8-10mm bar, order re-bending tool 1. For 12 to 16mm bar, order re-bending tool 2.
Installation Sequence
Tempcore high yield steel bars to BS4449
Bar dia.
Lap length ‘L’
8mm
350mm
10mm
400mm
12mm
500mm
16mm
650mm
Bar Centres e.g. 150mm
Case Lengths
Step 1
Step 2
Nail to inside of formwork or tie to reinforcement
14
Tear-off strip will show when formwork is struck
www.rom.co.uk
Step 3
Remove tear-off strip
Step 4
Straighten bars with rebending tool
Step 5
Lap to reinforcement steel
Reinforcement Connection The Startabox System ®
Startabox® Pattern References 20/1
20/1/2
20/2
20/2/2
32/1
37/1
37/2
37/3
37/4
37/5
38/1
38/2
39/1
53/1
61/1
First Pour
Second Pour
Additional Products Curved STARTABOX STARTABOX® can be manufactured to a customers desired internal or external radius. A typical situation would be the use of STARTABOX® in the construction of launder channels in round tanks in the water treatment industry. STARTABOX with Integral Waterstop (STARTASTOP) STARTABOX® can be manufactured incorporating a hydrophilic waterstop strip on both the internal and external face of the casing. This is especially useful for construction joints in below ground situations or within water retaining structures. The hydrophilic strip used is passed for use in potable water situations. STARTABOX Coupler Combinations Where reinforcement bar diameters or congestion of reinforcement bar restricts the use of STARTABOX®, RFA manufacture and supply a reinforcement bar coupler system. RFA can detail these couplers in conjunction with STARTABOX® and can even include them in the same joint detail. STARTABOX Cross Wall Connection Where two walls bisect each other STARTABOX® can be manufactured to accommodate the pull out bars for both faces of a wall in one single strip. This ensures the reinforcement runs continuously through the bisecting wall.
For details of your local depot, please turn to pages 34-35 Web: www.rom.co.uk Email: (Engineering Services) - engineering@rom.co.uk (Sales) - sales@rom.co.uk
15
Beamform
ROM Beamform & Clayshield
ROM Beamform A simple formwork solution for concrete ground beams & pile caps.
Beamform Clayshield Board
• Ideally suited for use with prefabricated beam cages • Reinforcement cages placed prior to Beamform • Lightweight easily positioned by one man • No specialist equipment required • Safe to handle • Easy to estimate quantities • Available off the shelf
Beamform Height
Product Code
Pack Size
350mm 400mm 450mm 500mm 550mm 600mm 650mm 700mm 750mm
BF35 BF40 BF45 BF50 BF55 BF60 BF65 BF70 BF75
64 48 48 32 32 32 32 32 32
Grippa Plate Spacer Castellated Clayshield
For further information and/or prices please contact your nearest ROM depot See pages 34-35
Standard Pack
Common base measurement of 1.0M x 1.2M. To a maximum height of 2.4M (including pallet) Stretch wrapped and marked with contents.
Grippa Plate Spacers
Clayshield Board
Cover
Product Code
Pack Size
2400 x 1200 x 50mm pack of 4 boards
40/50
BF4050
250
2400 x 1200 x 75mm pack of 6 boards
65/75
BF6575
250
2400 x 1200 x 100mm pack of 3 boards
For further sizes, prices and/or further information please contact your nearest ROM depot. See pages 34-35
Clayshield Prestige Board -
bonded with membrane to protect during installation
2400 x 1200 x 50mm pack of 4 boards 2400 x 1200 x 75mm pack of 6 boards 2400 x 1200 x 100mm pack of 3 boards For further sizes, prices and/or further information please contact your nearest ROM depot. See pages 34-35
16
www.rom.co.uk
For further sizes, prices and/or further information please contact your nearest ROM depot. See pages 34-35
Castellated Clayshield 1200 x 450 x 150mm 1200 x 450 x 200mm 1200 x 450 x 250mm 1200 x 550 x 150mm 1200 x 550 x 200mm 1200 x 550 x 250mm 1200 x 600 x 150mm 1200 x 600 x 200mm 1200 x 600 x 250mm
For further sizes, prices and/or further information please contact your nearest ROM depot. See pages 34-35
Beamform
ROM Beamform & Clayshield
Step 1
Step 2
50mm Concrete Blinding
50mm Sand Blinding
Castellated Clayshield
Step 3
Beamform is suitable for numerous types of foundations including: •radial •low thermal conductivity applications •raft edge toe beams •above ground and unreinforced applications •castellated & terracing applications.
Step 5
Step 4
ForFor contact detailsdetails of your oflocal your depot, local depot, pleaseplease turn toturn pages to page 34-35???Web: Web: www.rom.co.uk www.rom.co.uk Email: (Engineering Services) - engineering@rom.co.uk (Sales) - sales@rom.co.uk
17
Sheer System
ROM Shear Ladder System
ROM Shear Ladder System Used to resist punching shear in flat slab or piled slab construction. • Simple to fix • Time savings in placing • Variable link diameters, centres and heights • Supports top layer of reinforcement • Concrtete covers ensured • Easy to specify • Complies with the requirements of BS8110
Typical Section
T2 T1
Numbers, diameters and centres of links to suit engineers design and details.
B1 B2
Placing Sequence Step 1
1. Bottom layers of reinforcement fixed in position (B2 loose rebars may be fixed after Shear Ladders are placed onto B1 layer).
Step 2 2. Shear Ladders are placed onto B1 layer (recommended) that Shear Ladders are tied to B1 layer to avoid possible displacement
Step 3
3. Top reinforcement fixed. Shear Ladders can now act also as support chairs.
18
www.rom.co.uk
Plastic Spacers
Romchair (Heavy & Light), Wheel Spacers
Romchair (heavy)
Romchair (heavy) A heavy duty clip on spacer suitable for supporting bars up to a diameter of 25mm.
Product Code
To suit bar Diameter
Pack Size
Price per Pack
RC2025
8mm to 25mm
1000
£48.54
RC2525
8mm to 25mm
500
£26.47
RC3025
8mm to 25mm
500
£27.39
RC3525
8mm to 25mm
500
£29.52
RC4025
8mm to 25mm
500
£28.64
RC5025
8mm to 25mm
500
£37.04
Romchair (light)
Wheel Spacer
A plastic circular spacer that is simply pushed onto the rebar to provide cover through a full 360 degrees making it ideal for columns, walls and beams.
Product Code
To suit bar Diameter
Pack Size
Price per Pack
NC1512
4mm to 12mm
2000
£34.09
NC2016
4mm to 16mm
1000
£26.58
NC2516
4mm to 16mm
1000
£33.52
NC3016
4mm to 16mm
1000
£35.25
NC4016
4mm to 16mm
500
£24.91
NC5016N
4mm to 16mm
1000
£25.42
Romchair (light) A clip on chair spacer suitable for supporting bars up to a diameter of 16mm.
Wheel Spacer Product Code
To suit bar Diameter
Pack Size
Price per Pack
NW1508
4mm to 8mm
2000
£40.11
NW1514
10mm to 14mm
1000
£43.91
NW2008
4mm to 8mm
1000
£48.14
NW2012
8mm to 12mm
1000
£32.70
NW2510
4mm to 10mm
1000
£43.11
NW2520
12mm to 20mm
500
£32.66
NW3008
4mm to 8mm
500
£33.60
NW3020
10mm to 20mm
500
£33.09
NW3510
6mm to 10mm
500
£39.27
NW3520
12mm to 20mm
250
£26.40
NW4012
8mm to 12mm
500
£61.53
NW4020
12mm to 20mm
250
£39.25
NW5010
4mm to 10mm
250
£47.67
NW5020
12mm to 20mm
250
£48.25
NW6028
12mm to 25mm
100
£POA
For Forcontact detailsdetails of youroflocal yourdepot, local depot, pleaseplease turn toturn pages to page 34-35??Web: Web:www.rom.co.uk www.rom.co.uk Email: (Engineering Services) - engineering@rom.co.uk (Sales) - sales@rom.co.uk
19
Plastic Spacers
Pile Cage Rollers, Grade Plate Spacer, Romtrak, Zig-Zag Track Pile Cage Rollers
Pile Cage Rollers Designed for insitu piling and diaphragm wall application, with clip-on action to simplify fixing.
Grade plate spacer
Product Code
Cover
Pack Size
Price per Pack
SPCL4012
40mm
500
£68.38
SPCL5012
50mm
250
£44.46
SPCH5012
50mm
250
£75.84
SPCH7512
75mm
100
£40.45
SPCH7520
75mm
100
£42.38
Grade Plate Spacer
- 2.5/metre 2 (600M centre)
Product Code
Cover
Pack Size
Price per Pack
GP2530N
25mm & 30mm
500
£54.43
GP4050N
40mm & 50mm
200
£26.52
GP5060
50mm & 60mm
100
£32.36
GP6070
60mm & 70mm
100
£30.82
GP90100
90mm & 100mm
100
£29.72
Gradeplates are wide based plastic spacers designed to support mesh or bar reinforcement off polythene membranes without puncturing the surface. Usage 2.5/square metre (600 centres).
Romtrak
Romtrak Romtrack continuous plastic bar supports in 2 metre lengths. Ideal for use in conjunction with permanent metal deck formwork systems or sloping surfaces such as insitu staircases or ramps.
www.rom.co.uk
- 2.5/metre 2 (600M centre)
Product Code
Cover
Size Length
Price
PKR15
15mm
2M
£POA
PKR20
20mm
2M
£POA
PKR25
25mm
2M
£POA
PKR30
30mm
2M
£POA
PKR35
35mm
2M
£POA
PKR40
40mm
2M
£POA
PKR50
50mm
2M
£POA
Zig Zag Track
20
(SPCL - Light Duty SPCH - Heavy Duty)
Product Code
Cover
Pack Size
Price per Pack
ZZ15
15mm
100M
£75.12
ZZ20
20mm
100M
£78.87
ZZ25
25mm
100M
£86.39
ZZ30
30mm
100M
£100.23
ZZ35
35mm
80M
£137.32
ZZ40
40mm
80M
£146.43
ZZ50
50mm
80M
£209.08
Zig Zag Track Zig Zag is a plastic spacer supplied in 2 metre lengths. Ideal for supporting mesh in ground floor slab construction.
Concrete Spacers
Double & Triple Cover Spacers, Meshmen
Double & Triple Cover Spacers
Flat base - double cover
Double & Triple Cover Spacers are manufactured from glass fibre reinforced cement, and have been tested to ten times the load required under standard working practices. With a material strength of approximately 50N/mm2 they are strong, durable and the optimum choice for heavy duty steel fixing applications.
single cover spacers also available
Product Code
Covers Provide
Pack Size
Price per Pack
SF1520
15mm and 20mm
500
£26.00
SF2530
25mm and 30mm
500
£26.93
SF3040
30mm and 40mm
250
£17.57
SF3545
35mm and 45mm
200
£14.51
SF4050
40mm and 50mm
200
£15.83
SF5060
50mm and 60mm
100
£14.36
SF6075
60mm and 75mm
50
£8.71
Pack Size
Price per Pack
Flat base - Triple cover
The Spacers are as strong as the surrounding concrete. They give excellent bond and having the same expansion characteristics as concrete, eliminate any point of potential weakness.
Product Code
Covers Provide
3540T50
35mm/40mm/50mm 200
£15.86
Double Cover Flat based Spacers are designed for use on both horizontal and vertical applications. The flat base provides additional support and stability where the weight reinforcement is high.
Meshman Meshmen are manufactured in concrete material, and are particularly suitable for supporting steel fabric sheets on a polythene membrane layer, such as in ground floor slab construction. They provide dual cover of 40mm and 50mm to the bars. Recommended usage 2.5/square metre (600mm centres).
Meshman Product Code
Cover
Pack Size
Price per Pack
40MM50
40mm & 50mm
100
£POA
For details of your local depot, please turn to pages 34-35 Web: www.rom.co.uk Email: (Engineering Services) - engineering@rom.co.uk (Sales) - sales@rom.co.uk
21
Concrete & Wire Spacers
Heavy Duty Bars, Dekchairs & Ring Spacers
Square Bar
Heavy Duty Bars These heavy-duty bars are manufactured in varied lengths in a variety of square sections. Fixing costs are greatly reduced as the bars can simply be laid on the formwork or ground floor sub-base prior to the loading of the reinforcement cage. Other applications include their use as kickers and Formwork spacers.
Product Code
Covers Provide
Pack Size
Price per Pack
40SB250
40mm
20 x 250mm
£17.97
50SB250
50mm
10 x 250mm
£14.33
SQ25
25mm
1 x 1000mm
£2.23
SQ30
30mm
1 x 1000mm
£2.28
SQ35
35mm
1 x 1000mm
£2.30
SQ40
40mm
1 x 1000mm
£3.58
SQ50
50mm
1 x 1000mm
£4.47
SQ75
75mm
1 x 1000mm
£8.23
Also available in 250mm and 500mm lengths or size to suit. Please check pack quantities at time of ordering.
Dekchairs
Two Metre Continuous Dekchairs
1 Linear metre/metre2 (800mm centres)
Product Code
Height x Length
Pack Size
Price Each
ND050200
50mm x 2000mm
2M
£2.49
ND060200
60mm x 2000mm
2M
£2.52
ND075200
75mm x 2000mm
2M
£2.54
ND090200
90mm x 2000mm
2M
£2.57
ND105200
105mm x 2000mm
2M
£2.61
ND120200
120mm x 2000mm
2M
£2.68
ND135200
135mm x 2000mm
2M
£2.73
ND150200
150mm x 2000mm
2M
£2.89
ND165200
165mm x 2000mm
2M
£3.28
ND180200
180mm x 2000mm
2M
£3.44
ND200200
200mm x 2000mm
2M
£3.68
The standard two metre long Continuous Dekchairs are particularly suitable for ground floor slabs as their unique design eliminates any danger of puncturing damp proof membranes. Dekchair spacers can also be used between layers of reinforcement in suspended slabs and vertically in walls
Other heights available ie 250mm, 300mm etc.
Ring Spacers The circular Spacers provide a quick, easy and economical method of supporting reinforcement in concrete slabs. The spacers are delivered in 3.0 metre long straight lengths, which can then be formed into a circle of 1.0 metre diameter. Recommended a minimum of 4 per sheet.
22
www.rom.co.uk
Ring Spacers
1 Linear metre/metre2 (2000mm centres)
Product Code
Height x Length
Pack Size
Price per Ring
RS050320
50mm x 3000mm
3.0M
£2.15
RS060320
60mm x 3000mm
3.0M
£2.16
RS075320
75mm x 3000mm
3.0M
£2.17
RS090320
90mm x 3000mm
3.0M
£2.20
RS105320
105mm x 3000mm
3.0M
£2.34
RS120320
120mm x 3000mm
3.0M
£2.44
RS135320
135mm x 3000mm
3.0M
£2.52
RS150320
150mm x 3000mm
3.0M
£2.62
RS165320
165mm x 3000mm
3.0M
£2.71
RS180320
180mm x 3000mm
3.0M
£2.81
RS200320
200mm x 3000mm
3.0M
£2.93
Formwork Accessories Tie Bar System
Tie Bar System Tie Bar is produced from high tensile steel with a screw thread (deformation conforming to ASTMA 618 for reinforcing steel bars).
expendable plastic tube polythene cone
knock-on wing nut
Connectors/water barrier
Tie Rod
TR (Cutting service available at extra charge)
Product Code
Diameter
Pack Size Length
Price Each
15TR6000
15mm
6.0M
£20.21
15TR7500
15mm
7.5M
£25.31
20TR6000
20mm
6.0M
£49.42
TRWB
TRCN
Wing Nuts
CWN
Product Code
Diameter
Pack Size
Price Each
CWN15
15mm
1
£1.49
CWNF15
15mm
1
£3.01
CWN20
20mm
1
£3.24
Product Code
Diameter
Price Each
TRCN15
15mm
£3.91
TRWB15
15mm
£4.16
TRCN20
20mm
£7.87
TRWB20
20mm
£7.78
Tie Rod Sleeve & Cones
TRS
TSC
Product Code
Pack Size
Price Per Pack
TRS22
100M Pack
£56.63
TRS26
50M Pack
£57.20
TRC22
500
£23.11
TSC26
500
£67.52
Waler Plates
PWP90
HDW
Product Code
Style
To Suit Dia.
Price Each
PWP90
Pressed
15mm
£2.69
HDW
Heavy
15mm
£2.69
HDW20
Heavy
20mm
£6.30
Romplug - Tie Hole Filler Product Code
Pack Size
Price Per Pack
RPLUG 75N
7.5Kg
£20.22
RPLUG
For details of your local depot, please turn to pages 34-35 Web: www.rom.co.uk Email: (Engineering Services) - engineering@rom.co.uk (Sales) - sales@rom.co.uk
23
Formwork Accessories
Chamfer Edge Profiles, Circular Column Forms, Flupp Plugs, Steel Kickers Chamfer Edge Profiles
Chamfer Edge Profile
Plastic 45 degree mitre corner profiles, with or without a nailing flange, are available in a variety of widths. Supplied in 2.5M lengths.
Product Code
Price per 100M
Product Code
Price per 100M
WO11
£52.01
WN11
£85.05
WO15
£55.93
WN15
£129.43
WO20
£95.69
WN20
£158.55
WO25
£158.55
WN25
£202.93
WO30
£198.31
WN30
£239.45
WO
WN
Circular Column Forms
Circular Column Forms Product Code
Diameter
Price per Pack
DCF300 DCF350 DCF400 DCF450 DCF500 DCF550 DCF600 DCF650 DCF700 DCF800
300mm 350mm 400mm 450mm 500mm 550mm 600mm 650mm 700mm 800mm Further sizes available
£POA £POA £POA £POA £POA £POA £POA £POA £POA £POA
• Cost effective • Simple to erect • Lightweight • High quality finish • Lined or unlined available • Zipped forms available • Extensive range of sizes • Supplied cut to length • Top and bottom support yokes • Rectangular columns also available
Flupp Plugs
Flupp Plugs Flupp plugs are a rubberised plug designed to fill the void left once tie rod has been removed. Using flupp plugs minimises the amount of tie hole filler required.
Steel Kickers
24
- supplied in 2.5M lengths
Product Code
Width
Pack Size
Price per Pack
SK150
150mm
Each
£2.82
SK175
175mm
Each
£2.89
SK200
200mm
Each
£2.96
SK225
225mm
Each
£3.03
SK250
250mm
Each
£3.10
www.rom.co.uk
Product Code
Pack Size
Price per Pack
FLUPP22
1000
£132.90
FLUPP26
500
£112.67
Steel Kickers Steel Kickers are used in kickerless construction of walls eliminating the need for a concrete kicker and saving time in the construction cycle. The pressed steel leg of the ‘T’ shaped kicker is simply pushed into the wet concrete slab along the appropriate centre line of the proposed wall. Once set in position the adjustable horizontal bar forming the ‘T’ can be moved from side to side until the correct position is obtained. Once positioned, the horizontal bar can be tapped with a hammer to wedge it into the vertical slots on the leg.
Accessories
Conical Bolt Boxes, Holding Down Bolts, Non-Shrink Cementitious Grout Conical Bolt Boxes
Waxed Cardboard
(expanded metal bolts available to order)
Product Code
Length L
D and D
Price Each
Manufactured from waxed cardboard, these bolt boxes enable easy bolt location adjustment with minimum displacement of reinforcement and concrete.
CB1
229mm
70mm x 20mm
£1.08
CB2
305mm
92mm x 20mm
£1.46
CB3
380mm
108mm x 25mm
£2.09
CB4
457mm
114mm x 30mm
£3.20
CB5
534mm
118mm x 30mm
£4.01
CB6
610mm
132mm x 30mm
£4.31
For the ease of stripping and re-use, 25mm of the box should be left protruding and rotated before the concrete has completely set.
Polystyrene Product Code
Length L
D and D
Price Each
PB225
225mm
75mm x 40mm
£0.61
PB300
300mm
75mm x 40mm
£0.84
PB375
375mm
75mm x 40mm
£1.08
PB450
450mm
75mm x 40mm
£1.30
PB525
525mm
75mm x 40mm
£1.54
PB600
600mm
75mm x 40mm
£1.92
PB760
760mm
75mm x 40mm
£2.31
Holding Down Bolts Product Code
Length
Diameter
Price Each
HDB16300
300mm
16mm
£2.84
HDB16375
375mm
16mm
£3.39
HDB20300
300mm
20mm
£3.49
HDB20375
375mm
20mm
£3.72
HDB20450
450mm
20mm
£4.38
HDB20600
600mm
20mm
£5.57
HDB24375
375mm
24mm
£6.00
HDB24450
450mm
24mm
£6.76
HDB24600
600mm
24mm
£8.82
HDB PLATE
100mm x 100mm x 10mm
An extensive range of holding down bolts complete with nuts. Manufactured from grade 4.6 steel. Also available in grade 8.8 if required.
£1.83
Rompak Product Code
Yield
Pack Size
Price per Pack
RP25N
13.5 litres
25 Kgs
£7.62
Romgrout
Holding Down Bolts
Non-Shrink Cementitious Grout A high strength, free flowing, shrinkage compensated cementitious grout designed to cover the vast majority of grouting applications.
1 Sachet/50Kg OPC Cement
Product Code
Pack Size
Price per Pack
RG20N
20 Sachets
£40.44
Expanding grout admixture for use with sand and cement producing controlled expansion. Used where a controlled expansion is required to combat the effects of shrinkage.
For details of your local depot, please turn to pages 34-35 Web: www.rom.co.uk Email: (Engineering Services) - engineering@rom.co.uk (Sales) - sales@rom.co.uk
25
Accessories
Damp Proof Membrane, Plastic Screed Chairs, Metal Screed Chairs Damp Proof Membrane
Polythene Thickness Roll Microns Size
Price per Pack
BA1000BK BBA Black
250
4Mx25M
£POA
BA1200BK BBA Black
300
4Mx25M
£POA
BBA2000BK BBA Black
500
4Mx12.5M £POA
Product Code
High quality BBA approved polythene damp proof membrane that is available in various grades. All rolls when unfolded are approximately 4m wide
CENTFOLD BBA Centfold 300
4Mx25M
£POA
RSM
Romsheet
Medium
4Mx50M
£POA
RSH
Romsheet
Heavy
4Mx25M
£POA
Romtape
Romtape
Product Code
Width x Length
Pack Size
Price Each
50RT01
50mmx33M
1
£POA
75RT01
75mmx33M
1
£POA
Plastic Screed Chairs Plastic screedchairs are designed to support scaffold poles or screed boards for accurate levelling of concrete slabs. Placed in position at approximately 500mm centres, they can be adjusted (range 50mm) to the required level.
Type
A waterproof pressure sensitive tape for use on polythene sheet or formwork joints.
Plastic Screed Chairs Product Code
Products
Pack Size
Price per Pack
SCS
Saddles
100
£18.30
SCC
Collars
100
£12.14
SCT
Tube
10x2M
£49.41
SCB
Bases
100
£39.29
Once concreting operations are completed the scaffold tube or board can be removed from the top of the screedchair.
Metal Screed Chairs
Metal Screed Chairs Product Code
Slab Thickness
Pack Size
Price per Pack
MSC1
125 - 150mm
1
£3.67
MSC2
150 - 205mm
1
£3.82
MSC3
200 - 300mm
1
£4.24
MSC4
300 - 400mm
1
£4.62
Metal screed chairs are an alternative to the plastic screed chair system. They are supplied in two parts, the height can be simply adjusted by turning the stirrup in the base. Heavy duty Screed Chairs also available
26
www.rom.co.uk
Accessories
Screed Rail, Void Former, Crack Inducers
Screed Rail
Screed Rail
Product Code
METAL TOP RAIL: A reinforced concrete rail incorporating a 2mm wide x 22mm deep steel strip in its top face to improve both floor joint performance and appearance. These rails are available in a range of sizes.
Height
Length
Price per Rail
Metal Top Screed Rails
STANDARD SCREED RAIL: A reinforced concrete rail to suit general purpose concrete floors. These rails are available in a range of sizes.
MTR09539
95mm
3.9M
£POA
MTR14039
140mm
3.9M
£POA
Standard Screed Rail SSR10039
100mm
3.9M
£POA
SSR12539
125mm
3.9M
£POA
SSR15039
150mm
3.9M
£POA
Void Former
VF2020/VF2512
VF2010/VF2512
Product Code
Length
Width
Depth
Pack Size
Price per Pack
VF2010
3M
10mm
20mm
60M
£POA
VF2020
3M
20mm
20mm
60M
£POA
VF2512
3M
12mm
25mm
60M
£POA
VF2525
3M
25mm
25mm
60M
£POA
Crack Inducers PVC crack inducers are used in concrete slabs to induce controlled cracks at specific locations in continuously poured (jointless) concrete slabs. To work effectively it is recommended that the total depth of the top or top and bottom crack inducers should be between 1/4 and 1/3 of the total slab thickness.
Aluminium T Bar
Two part top
TOP TYPE: A two piece PVC crack inducer designed to be pushed into the top of a wet concrete slab to form a controlled crack. The top section can be removed to form a void approximately 25mm deep into which a floor seal can be applied.
PVC Void Formers in 4 sizes designed for forming grooves in concrete or nailing to formwork.
Crack Inducers Product Code
Bottom
Void Former
2 piece top inducer C2150 C2175 Bottom inducer C140Y C175Y Aluminium 'T' bar TB1 TB2
Depth
Pack Size
Price Per Pack
50mm 75mm
5M 5M
£9.62 £13.81
40mm 75mm
5M 5M
£8.82 £15.29
50mm 75mm
5M 5M
£110.50 £148.18
BOTTOM TYPE: Where slabs exceed 250mm in depth a bottom crack inducer used in conjunction with and placed immediately below the top crack inducer is recommended.
For details of your local depot, please turn to pages 34-35 Web: www.rom.co.uk Email: (Engineering Services) - engineering@rom.co.uk (Sales) - sales@rom.co.uk
27
Accessories
Dowel Bars, Expansion Dowel Bar Caps & Sleeves, D-BOND Compound
Dowel Bars
Dowel Bars can be supplied in various diameters either sawn end or cropped to specific lengths. Stainless Steel bars also available.
Dowel Bars Sawn End Product Code
Diameter
Length
Price per 100m
12DW0400 12DW0450 12DW0600 12DW0900 16DW0400 16DW0600 16DW0900 20DW0400 20DW0500 20DW0600 20DW0900 25DW0600 25DW0650
12mm 12mm 12mm 12mm 16mm 16mm 16mm 20mm 20mm 20mm 20mm 25mm 25mm
400mm 450mm 600mm 900mm 400mm 600mm 900mm 400mm 500mm 600mm 900mm 600mm 650mm
£0.39 £POA £0.57 £0.86 £0.68 £1.03 £1.53 £1.07 £1.34 £1.60 £2.39 £2.49 £POA
Dowel Caps
Dowel Bar Caps
Product Code
Diameter
Length
Pack Size
Price per Pack
DC12100
12mm
100mm
100
£27.05
DC16100
16mm
100mm
100
£29.50
DC20100
20mm
100mm
100
£33.16
DC25100
25mm
100mm
100
£34.67
DC32100
32mm
100mm
100
£45.06
Dowel Bar Sleeves
Dowel Bar Sleeves
Manufactured from high grade flexible PVC. They are tough, durable and have an average wall thickness of 1.25mm
Product Code
Diameter
Length
Pack Size
Price per Pack
DB12450
12mm
450mm
100
£30.24
DB16300
16mm
300mm
100
£31.70
DB20300
20mm
300mm
100
£30.70
DB25300
25mm
300mm
100
£31.04
DB32375
32mm
375mm
100
£56.00
D-BOND Compound
28
A range of Dowel bar debonding caps manufactured from rigid PVC tube with cork fixed into one end to act as a compression filler, which allows for expansion of dowel bars in construction joints
Product Code
Pack Size
Price per Pack
DB25
25 litres
£50.56
DB05
5 litres
£20.22
www.rom.co.uk
D-BOND Compound A bitumous based compound that can be applied to reinforcement dowel bars which when dry will provide a break in bond with it’s surrounding concrete. Complies with the DoT specification for Road and Bridge Works.
Accessories
Dowel Bar Cages, Frost Blankets, Foam Filler Board
Dowel Bar Cages
Supplied in separate half sections which are placed either side of the joint, contraction and expansion joint dowel bar cages can be used both in road and floor slab construction. Height shown is from the base of the cage to the underside of the dowel bar.
Expansion Joint Cradles
Contraction Joint Cradles
standard length 1.2M
standard length 1.2M
Price Each Half Cage
Product Code
Height Range of slab depths
65mm 150mm-180mm 1.2M
£5.13
CJ/751.2
75mm 150mm-180mm 1.2M
£3.14
EJ/901.2
90mm 190mm-230mm 1.2M
£6.24
CJ/951.2
95mm 190mm-230mm 1.2M
£3.74
EJ/1151.2
115mm 240mm-300mm 1.2M
£6.99
CJ/1251.2 125mm 240mm-300mm 1.2M Plastic connection sleeves 100No £8.66 per pack
£6.39
Product Code
Height Range of slab depths
EJ/651.2
Length L
Frost blankets
Foam Filler Board
closed cell polythene
Product Code
Pack Size
Price per Each
RFB150
2M x 75M
£POA
Length L
Price Each Half Cage
Frost blankets Frost blankets are used to protect concrete slabs in their early stages against freezing temperatures and can also be used in summer to prevent excessive heat or wind moisture evaporation from the surface. Supplied in 10mm thick closed cell polyethylene.
Foam filler Board
Other sizes available on request. 50,60,65 and 70kg/m3 density boards also available. Also available in Cork or Fibre Board
Product Code
Thickness Depth
min Kg/m3
Price Price per Pack per Pack
10F15010
10mm
30mm
10m
£POA
10F20010
10mm
200mm
30mm
10m
£POA
12F10010
12mm
100mm
30mm
10m
£POA
12F15010
12mm
150mm
30mm
10m
£POA
12F20010
12mm
200mm
30mm
10m
£POA
20F1502M
20mm
150mm
30mm
2m
£POA
20F1752M
20mm
175mm
30mm
2M
£POA
20F2002M
20mm
200mm
30mm
2M
£POA
Density 150mm
For details of your local depot, please turn to pages 34-35 Web: www.rom.co.uk Email: (Engineering Services) - engineering@rom.co.uk (Sales) - sales@rom.co.uk
29
Accessories
Tying Wire, Double Loop Ties, Rebar Safety Caps & Bentorub Tying Wire
Tying Wire Black annealed wire for the tying of reinforcement. Also available in stainless steel.
Material
W16C
16g Black Annealed Coil
£POA
W16M
16g Black Annealed 2 kgs
£3.24
W17C
17g Black Annealed 15 kgs
£POA
W18S/S
Stainless Steel
Kg
£POA
Each
£26.30
Pack Size
NIPS
Double Loop Ties
Double Loop Ties Product Code
Length
Pack Size
Price per Pack
DLT100A
100mm
1000
£9.49
DLT150A
150mm
1000
£10.17
DLT200A
200mm
1000
£11.85
DLT250A
250mm
1000
£13.10
DLT300A
300mm
1000
£14.01
DLT350A
350mm
1000
£15.13
DLTOOL
Tying Tool
Each
£21.21
Rebar Safety Caps
Supplied in 17g wire this tying wire system is a convenient method of wiring reinforcement together using a tying tool. The double loop tie is folded around the intersection of the reinforcement, the hook of the tying tool is then placed through the loops and pulled. The twisting action of the tool forms a secure tie.
Rebar Safety Caps
Rebar Safety Caps are specifically designed for use in the construction industry and fit over the ends of protruding bars reducing the risk of injury.
Bentorub
30
Price per Pack
Product Code
Product Code
Bar Diameter
Pack Size
Price per Pack
RSC6/16
6mm to 16mm
250
£56.81
RSC12/25 12mm to 25mm
125
£65.30
RSC25/50 25mm to 50mm
100
£79.45
NB self adhesive
Product Code
Width x Thickness
Length/ Roll
Price per Pack
AQ2520
20mm x 10mm
6.0M
£41.88
www.rom.co.uk
Bentorub A synthetic elastomeric compound that expands to twice its normal size (by volume) when in contact with water, provides a self-sealing and easy to use alternative to traditional methods. Self adhesive fixing is ideal for all water retaining structures.
Accessories
Hydrotite, PVC Waterstop, Levelling Shims
Hydrotite Product Code
Hydrotite Width x Thickness
HYDT0001 7mm x 25mm
Length/Roll
Price per Pack
10M
£68.80
PVC Waterstop
PVC Waterstop ROM Waterstops are manufactured from high quality PVC and are specifically developed to seal joints in concrete. • Elongation 300% (nominal) • Tensile strength 13.8/mm2 (2000p.s.i.) • BS softness 45 @ 20 deg C • Relative density 1.3 • Complies with BS2571 and BS2782. Hot knives and jointing jigs are available.
Hydrotite is a unique co-extruded section of neoprene rubber, which expands when in contact with water, providing a self sealing and easy to use alternative to traditional methods. Ideal for all water retaining structures.
Full range of intersections & accessories available
Product Code
Width
Roll Length
Price per m
AA200
200mm
15M
£POA
AA250
250mm
10M
£POA
DA200
200mm
15M
£POA
DA250
250mm
10M
£POA
A200
200mm
15M
£POA
A250
250mm
15M
£POA
D200
200mm
15M
£POA
D250
250mm
15M
£POA
Levelling Shims Thickness Product Code
Square shim
Pack Price per Product Code Size Pack
Pack Size
Price per Pack
2mm
70LS02H 250
£18.49
70LS02P 250
£19.68
3mm
70LS03H 250
£23.49
70LS03P 250
£28.90
5mm
70LS05H 125
£19.26
70LS05P 125
£25.05
7mm
70LS07H 125
£25.80
70LS07P 125
£33.89
9mm
70LS09H 125
£32.73
70LS09P 125
£39.67
Levelling Shims Plastic shims are ideal for packing during erection of precast units. Horseshoe shims are 75mm x 75mm and square shims are 70mm x 70mm.
Horseshoe shim
For details of your local depot, please turn to pages 34-35 Web: www.rom.co.uk Email: (Engineering Services) - engineering@rom.co.uk (Sales) - sales@rom.co.uk
31
Chemicals
Concrete Surface Treatments
Romcure WW
Chemcure Standard
Product Code
Pack Size
Price per Pack
RCWW20N
20 litres
£POA
RCWW200N
200 litres
£POA
An aqueous silicate solution for a low cost general purpose curing agent.
RCWWT20N
20 litres
£POA
Spray applied.
RCWWT200
200 litres
£POA
Romcure Standard
Usage approximately 5.5M2 /litre
Chemcure R75
Product Code
Pack Size
Price per Pack
RCST25N
25 litres
£POA
A 75% efficiency rated resin based curing compound.
RCST200N
200 litres
£POA
Can be supplied tinted.
RCST25N
25 litres
£POA
Spray applied.
RCSTT205
200 litres
£POA
Romcure Super
Pack Size
Price per Pack
RSCU25N
25 litres
£POA
RSCU200N
200 litres
£POA
Romcure Super Aluminised
Chemcure R90 Aluminised
Product Code
Pack Size
Price per Pack
RSCUA25N
25 litres
£POA
RSCUA200
200 litres
£POA
A 90% efficiency rated resin based curing compound. Spray applied. Usage approximately 5.5M2 /litre
Spray applied. Usage approximately 5.5M2 /litre
Curecote super
Product Code
Pack Size
Price per Pack
RCSEA25N
25 litres
£POA
RCSEA200
200 litres
£POA
Product Code
Pack Size
Price per Pack
RTUF15N
15 litres
£POA
RTUF200N
200 litres
£POA
ROMTUF
Usage approximately 5.5M2 /litre
Chemcure R90
Product Code
Romcure Sealer
This product seals the concrete surface, acts as a curing membrane and adds abrasion resistance. Spray applied Usage approximately 6-8M2 /litre
Conseal Silicate
Concrete Retarder
Applied to concrete floors it will improve resistance to oil and provide a case hardened surface. Brush applied. Usage approximately 6-8M2 /litre
Aquatard TF
Product Name
Product Code
Pack Size
Price per Pack
Aquatard TF
RTDCF05N
5 litres
£POA
Aquatard TF
RTDCF25N
25 litres
£POA
Flexible Waterproof Membrane
32
Water white or tinted with fugitives (T).
Top face retarder, water based retarder designed to expose aggregate on horizontal surfaces.
NuProof
Product Name
Product Code
Pack Size
Price per Pack
NuProof
RCOAT25N
25 litres
£POA
NuProof
RCOAT200
200 litres
£POA
www.rom.co.uk
An alkali resistant rubberised bituminous coating with excellent adhesion to sound building materials including asphalt surfaces. Flexible at low temperatures and resists soffening. Ideal as a flexible waterproof membrane on bridge abutments and external walls prior to backfilling.
Chemicals
Formwork Chemicals, Fillers & Tapes
Mould Oils
Formstrike
Product Code
Pack Size
Price per Pack
RO05N
5 litres
£POA
Spray or brush applied.
RO25N
25 litres
£POA
Usage approximately 20-30m2 /litre.
RO205N
205 litres
£POA
Chemical Release Agent
Chemlease
Product Code
Pack Size
Price per Pack
RL25
5 litres
£POA
RL205
25 litres
£POA
Repair Compounds
A general purpose mould oil (catergory 2).
A general purpose chemical release agent. Spray applied. Usage approximately 35-50m2 /litre.
Formfil
Product Name
Product Code
Pack Size
Price per Pack
ROMFILL
RFL015N
1.5kg
£10.84
Two part polyester formwork patch repair filler (suitable for timber, steel or fibreglass).
RFL07N
7kg
£37.56
Apply by trowel.
RFL01TN
Tube
£2.89
Form Applied Retarder
Aquatard Formwork Pack Size
Price per Pack
RTDMA05N
5 litres
£31.26
RTDMA25N
25 litres
£131.45
Product Name
Product Code
Pack Size
Price per Pack
ROMTAPE
50RT01
Each
£79.04
50mm 33M rolls.
ROMFILL
RF25
25 rolls
£114.41
Closed cell tape for formwork joints.
SPRAYERS
SP07 plastic
7 litres
£67.90
SP09 metal
9 litres
£112.79
PolyCapacity: Plastic - 7 litres Metal - 9 litres
Product Name
Product Code
ROMTARD MA
Formwork applied concrete surface retarder. Spray or brush applied. Usage approximately 15-16M2 /litre.
Formwork Joints
For details of your local depot, please turn to pages 34-35 Web: www.rom.co.uk Email: (Engineering Services) - engineering@rom.co.uk (Sales) - sales@rom.co.uk
33
Depot Locations
Depot Locations
Whitburn ROMTECH Ireland (Pages 36-37)
Newcastle
Sheffield
Lichfield
ROMTECH Cannock (Pages 36-37)
Engineering Department for the North
Newport
Witham Engineering Department for the South
Engineering Services (North)
Engineering Services (South)
Telephone: 0870 0113601 Fax: 01543 417965
Telephone: 0870 0113605 Fax: 01376 533225
Email: Engineering: engineering@rom.co.uk Sales: sales@rom.co.uk
34
www.rom.co.uk
Depot Locations
Murraysgate Industrial Estate Whitburn West Lothian EH47 0LE
Whitburn
Unit 10 Blayton Industrial Park Chainbridge Road Blaydon-on-Tyne NE21 5AB
Newcastle
Tel: 0870 011 3608 Fax: 0870 011 2342
Tel: 0870 011 3607 Fax: 0870 011 2503
B8084
A695
A1
M8
A706
CHAINBRIDGE ROAD
A695
A695 COWEN ROAD
GOODS ENTRANCE
B7066
A69
A1
RING ROAD
A1
FIRE STN.
B6317 SHIBDON ROAD
B7069 WEST MAIN ST
B6317
710 Brightside Lane Sheffield South Yorkshire
Sheffield
Lichfield Head Office
Tel: 0870 011 3601 Fax: 0870 011 3606 A6102 UPWELL ST.
Tel: 0870 011 2883 Fax: 0870 011 2884 A6106 BRIGHTSIDE LANE
B6082 CARLISLE ST EAST
Eastern Avenue Trent Valley Lichfield Staffordshire WS13 6RN
A5192 EASTERN AVENUE VULCAN ROAD
BURTON
A6102 HAWKE ST.
A5127 TRENT VALLEY ROAD
A6178 ATTERCLIFFE COMMON
B6083 NEWHALL RD. A6106 BRIGHTSIDE LANE
A5129 CAPPERS LANE
A38 B6085
Rush Drive Pen-Y-Fan Industrial Estate Crumlin, Newport, South Wales NP11 3EJ
Newport
Witham
Wheaton Road Witham Essex CM8 3BU Tel: 0870 011 3605 Fax: 0870 011 3211
Tel: 0870 011 3603 Fax: 0870 011 4562
JCT 22
CHARLES STREET
B1389 NEWLAND ST ROAD
RUSH DRIVE PARKWAY
FREEBOURNES ROAD
B1018
B1018
WHEATON ROAD
A12
PARKWAY
Based upon Ordnance Survey Maps. © Crown Copyright. All rights reserved. Temporary Ref WL8153
For details of your local depot, please turn to pages 34-35 Web: www.rom.co.uk Email: (Engineering Services) - engineering@rom.co.uk (Sales) - sales@rom.co.uk
35
ROMTECH, a ROM Group company, is a multi-disciplined manufacturing company specialising in the supply of engineered reinforcement products, to the housing, Structural and Civil Engineering industry. To accompany our range of products we are able to offer our customers first class levels of service together with an innovative approach to problem solving and product design, always being fully responsive to ever changing requirements. Quality is essential in an environment as critical and as potentially dangerous as the construction site, we therefore ensure the highest level of quality through third party certification and our in house QA staff. We pride ourselves in driving health and safety issues to the top of our agenda, ensuring continuous improvement whilst providing solutions to improve safe working practices on site.
PILING ROMTECH Piling understands the needs of piling contractors. The absolute requirement to meet deadlines to avoid standing piling rigs and crews, along with the conflicting difficulties in obtaining precise initial design information required for a manufacturing start up. ROMTECH is well versed and experienced in operating within this demanding environment. It offers one-stop shopping for all your existing piling reinforcement needs along with a unique service to develop new product lines and so meet the challenges of the future.
piling@rom-tech.co.uk
Products and services include: • Factory prefabricated pile cages
• Cage site-assembly packages
• Loller compliant lifting gear
• Pile cage accessories
• Cage formers
• Fabrication drawings
• Technical support GEOTECHNICAL ROMTECH Geotechnical supplies a broad range of specialist geotechnical products for use in ground stabilisation and structural support. We currently focus our business towards soil nailing, anchoring and rock bolting, but our objective is to introduce a more comprehensive range of products in the near future. To support these specialist markets we provide a technical support service that is tailored to meet the requirements of our customers. Products and services include: • ROMTECH fully threaded bar grades 550, 800, 1050 and accessories • ROMTECH hollow bar self drill soil nails and anchors (injection anchors) • ‘XpandX’ is a unique mechanical anchoring system for soil nailing and rock bolting • Comprehensive technical support • Large stocks of standard products – black and galvanised
36
www.rom.co.uk
geotechnical@rom-tech.co.uk
GROUNDWORKS ROMTECH Groundworks support their customer base by providing ‘Total Package Solutions’ with products offering significant savings over traditional methods of construction. This service is achieved by continuous development of new and innovative products to solve construction problems. Products and services include: Beamform permanent formwork, prefabricated cages, Fillshield, Thermafloor, clayheave protection, shear ladders etc The groundworks division will provide: • A fast response to your enquiry.
groundworks@rom-tech.co.uk
• Full take-off and quantification of products from drawings and bar schedules. • Full in-house engineered support. • Electronic ordering. TUNNELLING & MINING
ROMTECH Tunnelling are the UK’s major manufacturer of tunnel lining reinforcement products, supplying major projects that include Channel Tunnel, Dublin Port Tunnel, Heathrow Express Tunnels, Copenhagen Metro, Jubilee Line Tunnels etc. Our range of product includes our own design of segment cages and lattice girder systems, available from licensed manufacturers in Australia and the USA, developed in house. Products and services include: • Lattice girders
tunnelling@rom-tech.co.uk
• Segments cages • Shotcrete mesh • Rock dowels • Rock bolts • Spiles • Self drilling spiles • Radiused ladder support frames and • Technical support
Ireland
M1
www.rom-tech.com Unit 8, Silverwood Business Park 70 Silverwood Road Craigavon Northern Ireland BT66 6LN Tel:0870 011 3609 Fax: 0870 011 3614 JCT 10
BELFAST
KILN RD
SILVERWOOD RD
LOUGH RD
M6 TOLL JCT 7
B4154 WALSALL ROAD
HEDNESFORD ROAD M6 TOLL JCT 6
A5
FRANCIS ST
EDWARD ST EASYWAY
Cannock
Unit 16, Watling Street Watling Street Business Park Cannock WS11 9XG Staffordshire Tel: 0870 011 3610 Fax: 0870 011 4568
B4154 LIME LANE
A5
A5 WATLING STREET
PORTADOWN RD
A452 CHESTER ROAD
Based upon Ordnance Survey Maps. © Crown Copyright. All rights reserved. Temporary Ref WL8153
For details of your local depot, please turn to pages 34-35 Web: www.rom.co.uk Email: (Engineering Services) - engineering@rom.co.uk (Sales) - sales@rom.co.uk
37
Index
Accessories
25-31
Bentorub Conical Bolt Boxes Polystyrene Conical Bolt Boxes Waxed Cardboard Conical Bolt Boxes Crack Inducers PVC Crack Inducers Damp Proof Membrane Polythene Damp Proof Membrane D-BOND Compound Dowel Bar Cages Contraction Joint Cradles Expansion Joint Cradles Dowel Bar Sleeves Dowel Bars Dowel Caps Foam Filler Board Frost Blankets Holding Down Bolts Hydrotite Levelling Shims Horseshoe Shims Square Shims Metal Screed Chairs Non-Shrink Cementitious Grout Romgrout Rompak Plastic Screed Chairs PVC Waterstop Rebar Safety Caps Romtape Screed Rail Tying Wire Black Annealed Tying Wire Double Loop Ties Void Former
Beamform & Clayshield Beamform Grippa Plate Spacers Clayshield Castellated Clayshield Clayshield Board Clayshield Prestige Board
Chemicals
30 25 25 25 27 27 26 26 28 29 29 29 28 28 28 29 29 25 31 31 31 31 26 25 25 25 26 31 30 26 27 30 30 30 27
16-17 16-17 16 16-17 16 16 16
32-33
Concrete Surface Treatments Concrete Retarder Flexible Waterproof Membrane Romcure Sealer Romcure Standard Romcure Super Romcure Super Aluminised Romcure WW ROMTUF Fillers & Tapes Formwork Joints Repair Compounds Formwork Chemicals Chemical Release Agent Form Applied Retarder Mould Oils
32 32 32 32 32 32 32 32 32 33 33 33 33 33 33 33
Couplers Ancon Couplers MBT Coupler Tapered Thread Positional Couplers Tapered Thread Standard Couplers Tapered Thread Transition Couplers Threading Charge Lenton Couplers Position P14 Couplers Standard A12 Couplers Transition R11 Couplers Threading Charge
Formwork Accessories Chamfer Edge Profiles Circular Column Forms Flupp Plugs Steel Kickers Tie Bar System
Reinforcement Bar Shape Codes Flying End Fabric Kwikfix Fabric Kwikfix+ Fabric Prefabrication Readyfit Fabric Standard Fabric Weights and Area's of Steel
Sheer Ladders Spacers Dekchairs Double Cover Spacers Grade Plate Spacers Heavy Duty Bars Square Bar Meshmen Spacers Pile Cage Rollers Ring Spacers Romchair Spacers Romtrak Triple Cover Spacers Wheel Spacers Zig-Zag Track
Startabox System Startabox Additional Products Startabox Case Sizes Startabox Installation Sequence Startabox Pattern References
ROMTECH Geotechnical Groundworks Piling Tunnelling & Mining
Terms & Conditions Health and Safety Statement
38
www.rom.co.uk
12-13 13 13 13 13 13 13 12 12 12 12 12
23-24 24 24 24 24 23
4-11 4 7 9 10 11 8 6 5
18 19-22 22 21 20 22 22 21 20 22 19 20 21 19 20
14-15 15 14 14 15
36-37 36 37 36 37
39 40
Terms & Conditions
ROM LIMITED TERMS AND CONDITIONS OF TRADING 1. INTERPRETATION In these Conditions (unless the context otherwise requires) the following words shall have the following meanings: "Buyer" means a person to whom the Seller supplies or is to supply Goods and Services pursuant to a Contract; "British Standards" means those standards set by the British Standards Institute applicable to the Goods and Services; "Conditions" means these terms and conditions of sale; "Contract" means a contract for the sale of Goods and Services made by or on behalf of the Seller with a Buyer; "Goods" means the goods which the Seller supplies pursuant to a Contract; "Services" means the services which the Seller provides pursuant to a Contract; "Seller" means ROM Limited a company registered in England and Wales under number 213629 whose registered office is at Eastern Avenue, Trent Valley, Lichfield WS13 6NR; "Working Day" means any day from Monday to Friday (inclusive) which is not Christmas Day, Good Friday or a statutory holiday in England. 2. GENERAL 2.1 These Conditions are to apply in preference to and supersede any terms and conditions referred to offered or relied on by the parties whether in negotiation or at any stage in the dealings between the Seller and Buyer with reference to the Goods to which this Contract relates. They represent the entire agreement between the parties. Without prejudice to the generality of the foregoing the Seller will not be bound by any standard or printed terms furnished by the Buyer in any document unless such terms are accepted in writing by a duly authorised executive of the Seller. No oral variation of these Conditions can be agreed in any circumstances. 2.2 Any representations made prior to the formulation of the Contract, including any literature, descriptions, specifications, oral or written statements or any combination, the Buyer hereby acknowledges were not relied on by him. The Buyer hereby acknowledges that he has not entered into this Contract on the basis of any representation, made oral or in writing, by the Seller, its employees or agents and that he therefore relied on his judgment alone when entering into the Contract. 2.3 In the event of delivery being delayed by fire, accident, strikes, lockouts, delay in receipt of materials or bought-in goods or any other Condition beyond the reasonable control of the Seller, a reasonable extension of time for delivery shall be granted and the Buyer shall pay such reasonable extra charges as shall have been occasioned by the delay. However, the Seller shall have the right to suspend or terminate the Contract, on giving written notice. During any period of such suspension the Seller shall have the right to terminate the Contract, subject to further notice in writing. Where the Contract is suspended by the Seller all obligations imposed on either party by the contract shall be held in abeyance for the period of such suspension. Where the Seller elects to terminate the Contract, such termination shall not affect liabilities on the Buyer’s part which fell due before termination. 2.4 Any quotation is without engagement and is subject to written confirmation by the Seller on receipt of order. 2.5 The Seller’s quotation (if any) is made on the understanding that the whole of the quantity of the Goods and/or Services quoted for will be ordered and supplied. Cancellation of all or part will not be valid unless accepted by the Seller in writing in which case the Seller will be entitled to revise its quotation. 2.6 Prices quoted are based upon current conditions, costs of labour, materials and statutory charges and are subject to increase without notice to take account of variations of alterations in the same. The Seller accordingly reserves the right to adjust the invoice in the event of any increase in the cost of materials, transport or of labour and/or take account of any other costs, which may arise as a result of legislation or by reason of any other event unknown to the Seller at the date of the quotation. 2.7 The following provisions shall apply to all Goods supplied: 2.7.1 There will be a minimum charge of £100.00 per invoice. 2.7.2 Any orders or call-offs consisting of Rebar under 8 tonnes per delivery or Fabric under 2 tonnes per delivery will attract an additional lump sum charge of not less than £50.00. 2.7.3 There will be an additional minimum charge of £60.00 per crane off-load delivery. 2.7.4 All other deliveries to a value of less than £400.00 will be subject to a minimum carriage charge of £50.00 per delivery. 2.7.5 Where the Buyer requests that the Goods be dispatched by Courier Express, TNT, British Rail, Red Star or similar means, carriage will be charged and payable at an agreed cost. 2.7.6 Any charges referred to in Condition 2.7.2 or 2.7.3 above shall be in addition to the Seller's standard carriage charges. 2.7.7 Rebar schedule amendments notified after receipt of original schedule will be charged at £25.00 per amendment or a lesser figure as may from time to time be agreed. 2.7.8 The Seller reserves the right to make a “waiting time” charge for the time during which a lorry making a delivery is held on site in excess of a period of one hour. 3. DELIVERY 3.1 Contract dates for the delivery or collection of the Goods or performance of the Services are to be accepted by the Buyer as estimates only and no action will lie for failure on the Seller’s part, however caused, to meet any such dates. 3.2 Where the Buyer fails to accept delivery of the Goods, or fails to arrange for their collection at the agreed time, then the risk in such Goods is to lie with the Buyer and the Seller may, without prejudice to any other rights it may have, make such of the following provisions as it considers appropriate: 3.2.1 Store the Goods at the Buyers expense. 3.2.2 Insure the Goods at the Buyers expense. 3.2.3 Make additional charges for any further transport costs. 3.2.4 Proceed to sell the Goods, on giving written notice to the Buyer, and any loss suffered shall be debt owed by the Buyer to the Seller as though it were part of the invoice price. 3.2.5 Maintain a lien on any property of the Buyer with a right to sell any such property which is in the Seller's possession, until such time as the Buyer has paid in full all amounts outstanding. Where the Seller exercises its rights to sell, it will account to the Buyer for any surplus after allowing for all amounts outstanding and for any costs and expenses incurred in relation to the goods. The foregoing provisions are also to apply where delivery or collection of the goods has been delayed or deferred at the Buyers request, even though the Seller may have agreed to such request 3.3 Where the Goods have been received by the Buyer, whether or not such receipt of is acknowledged in writing, the Buyer hereby agrees that he will be deemed to have examined the Goods and to have accepted that they meet fully the obligations imposed by this Agreement on the Seller. 3.4 The following shall apply as to the place of delivery: 3.4.1 The place of delivery shall be such place as has been previously expressly agreed or implied, or where there is no indication, it shall be the Buyer's usual place of business. 3.4.2 Where the place has been previously agreed, the Seller may, at its absolute discretion, agree to a request for alteration, the Buyer being responsible for any additional costs involved. 3.4.3 The foregoing provisions are without prejudice to the Seller's rights to change any place of delivery previously agreed. The Seller will bear any costs necessitated by such change by deduction from invoice price or other means, except where such changes arise from circumstances for which the Buyer could reasonably be held responsible. 3.5 Where a change of place is necessitated for reasons for which the Buyers is properly held responsible, and in the opinion of the Seller no suitable alternative place can be determined, then the contract may be terminated at the discretion of the Seller and in this event an action may be maintainable against the Buyer as a breach of Contract. 3.6 At the cost of the Buyer the Seller will arrange for the transportation of the Goods as the Buyer's agent to the Buyer by a haulage company Such transportation costs shall be included on the invoice to the Seller for the Goods 3.7 Unless otherwise expressly agreed, the Seller may effect delivery in one or more instalments. If delivery is effected by instalments, each instalment shall be treated as a separate Contract. 3.8 Section 32(2) of the Sale of Goods Act 1979 does not apply and the Seller is
not required to give the Buyer the notice specified in section 32(3) of that Act. 4. WARRANTY AND LIABILITY 4.1 Liability for short delivery, defective Goods, damage in transit or faulty workmanship will not be considered unless notification in writing is received by the Seller as follows: 4.1.1 In the case of Goods delivered by the Seller their servants or agents to site, or to the premises of the Buyer, within seven days of such delivery and on condition that the Goods so delivered shall be retained as delivered and made available for inspection by or on behalf of the Seller for a reasonable time after such notification. 4.1.2 In the case of materials collected from the Seller by or on behalf of the Buyer, within seven days of such collection and on condition that the materials so delivered shall be retained as delivered and made available for inspection by or on behalf of the Seller for a reasonable time after such notification. 4.1.3 In the case of Services carried out by the Seller on site, within seven days of the execution of such Services and before being concreted and/or permanently incorporated in the structure. 4.2 For the purposes of this Condition time shall be of the essence and in the absence of such notification as aforesaid the quantity and condition of the Goods delivered or collected as the case may be shall be deemed to be in all respects correct and satisfactory. 4.3 Except as set out in these Conditions, all conditions, warranties and representations, expressed or implied by statute, common law or otherwise, in relation to the supply, non supply or delay in supplying the Goods and Services are excluded to the extent permitted by law. 4.4 Steel reinforcement will be supplied in accordance with the relevant British Standard and applicable standards of UK CARES (or its successor body). Other Goods and Services will be supplied to the Seller's usual quality standard. No warranty as to fitness for purpose is to be implied for any Goods or Services. Tools, jigs or any other special equipment used in the course of manufacture or supply shall remain the property of the Seller. 4.5 It is agreed that a film of rust or mill scale on reinforcement will not constitute grounds for rejection. 4.6 No representation or statement made or purporting to be made by any person on the Sellers behalf shall be binding unless subsequently confirmed in writing by the Seller. 4.7 The Seller’s liability in respect of any defective Goods or Services supplied by them or faulty workmanship regarding which a valid claim has been made under Condition 14 hereof will be limited to the delivery to site at the Seller’s expense of Goods to replace the defective Goods or re-perform the Services or the remedy of the faulty workmanship and will not extend to any other damage or loss suffered by the Buyer. In particular, but without prejudice to the generality of the foregoing, the Seller will not be liable for loss of profit, damage to plant or for any expenditure incurred on goods supplied or remedial works performed or any consequential or special loss or damage sustained by the Buyer nor for any liability to a third party which the Buyer may incur. 4.8 Nothing in these Conditions shall exclude or restrict any liability: 4.8.1 death or personal injury resulting from negligence; or 4.8.2 breach of the obligations arising from section 12 of the Sale of Goods Act 1979; or 4.8.3 fraud or deceit. 4.9 Whenever any third party, including any prosecuting authority, brings an action or intends to bring an action against the Seller as a result of any actual or alleged criminal offence, tort, breach of contract by the Buyer, then the Buyer undertakes to provide the Seller with a complete indemnity in relation to such action. The Buyer shall also indemnify the Seller, to the full extent of any liability incurred, that arises from any negligent act or omission on the part of the Buyer, whether such liability results from litigation or any settlement reached by the Seller with or without the Buyers consent or howsoever. 5. RISK AND TITLE 5.1 All risk in relation to the Goods and Services passes to the Buyer on collection of the Goods by the haulage company pursuant to Condition 3.6. However, this provision is without prejudice to the provisions of Condition 5.2 relating to the Seller's reservation of title. 5.2 Property in the Goods shall not pass to the Buyer until the entire invoice price under the Contract or under any other Contract between the Seller and the Buyer, has been paid in full and this provision is to apply to associate or subsidiaries of either party. Until such a time the Buyer holds such Goods as bailee on the Seller's behalf subject to the provisions following: 5.2.1 The Goods will be stored separately and be identifiable as belonging to the Seller subject to requirements of normal usage. 5.2.2 The Goods are covered by the Buyer’s policy of insurance and he will assign the benefits of such policy to the Seller at its request. 5.2.3 Any monies received by the Buyer for Goods supplied to him by the Seller will be retained in a separate account and he will hold such monies as trustee on the Seller's behalf. 5.2.4 The Goods are to be maintained in a usable condition. 5.2.5 The Seller shall be entitled to enter any premises where the contract goods are stored and take possession of such Goods at any time before full payment is received. 5.2.6 Where the Goods, or any part of such Goods, are incorporated with any other goods, the Buyer will make every reasonable endeavour to ensure that the title in such goods (or in goods that may result from the incorporation of the contract goods), passes to the Seller and the foregoing provisions of this clause shall be considered to apply to such goods. 6. EXPORT SALES 6.1 If the Goods are sold CIF or FOB or on the basis of other international trade terms, the meaning given to such terms in the International Chamber of Commerce INCOTERMS (as revised from time to time) shall apply, except where inconsistent with any of the provisions contained in these Conditions. 6.2 The Buyer shall secure the price of any Goods sold under an international supply contract as defined by section 26 of the Unfair Contract Terms Act 1977 by establishing in the Seller's favour an irrevocable letter of credit on terms satisfactory to the Seller immediately upon receipt of the Seller's acceptance of an Order and confirmed by a UK bank acceptable to the Seller. 7. PAYMENT 7.1 Payment for Goods and Services shall be made on or before the end of the calendar month following the month of delivery or collection and payment for Goods and Services shall not be delayed if the Goods supplied are not used nor shall payment be delayed pending settlement of any claim against the Seller and accordingly the Buyer shall not be entitled to any right of set off against the purchase price. Non-compliance with the Sellers payment terms shall entitle the Seller to withhold future deliveries and / or labour forthwith. The Buyer shall not be entitled to withhold or delay the whole or any part of payment on the grounds of insufficient or no proof of delivery unless the Buyer has given written notice within 7 days of the invoice date requiring proof of delivery. The delivery note/invoice copy receipted on behalf of the Buyer or such other reasonable evidence as may be produced shall be sufficient proof of delivery for this purpose. The Buyer shall otherwise be entitled to require proof of delivery. In the event of payment not being made in accordance with the provisions of this clause then: 7.1.1 The Seller will be entitled to an indemnity from the Buyer for all direct labour, legal and other costs incurred in the recovery of amounts which become overdue and; 7.1.2 Payment for all other goods supplied to the Buyer by the Seller shall forthwith become due for immediate payment. 7.2 The Seller shall (if applicable) add to the price of the Goods and Services, and the Buyer shall pay, an amount equal to any VAT or other sales tax or duty applicable from time to time to sales or supplies of such Goods and Services. 7.3 If the Buyer fails to pay any amount due to the Seller under any Contract on the due date, interest shall be added to such amount at the rate of 4% over the base rate for the time being of Barclays Bank plc for the period from and including the date of receipt (whether before or after judgment). 7.4 If, in the Seller's view, the Buyer's credit-worthiness deteriorates before delivery of the Goods or performance of the Services, the Seller may require payment in full or in part of the price prior to delivery or performance, or the provision of security for payment by the Buyer in such form as is acceptable to the Seller. 7.5 The Seller reserves the right to alter or withdraw at any time any credit allowed to the Buyer. 7.6 The Seller may offset any amount owing to it from the Buyer against any
amount owed to the Buyer by the Seller. 8. INFRINGEMENTS OF THIRD PARTY RIGHTS 8.1 The Seller is not liable to the Buyer if the Goods or Services infringe or are alleged to infringe the rights of any third party if such Goods or Services are supplied pursuant to an international supply contract as defined by section 26 of the Unfair Contract Terms Act 1977. 8.2 If at any time it is alleged that the Goods or Services infringe the rights of any third party in the UK or if in the Seller's reasonable opinion such an allegation is likely to be made, the Seller may at its option and its own cost: 8.2.1 modify or replace the Goods or re-perform the Services in order to avoid the infringement; or 8.2.2 procure for the Buyer the right to continue using the Goods or benefit from the Services; or 8.2.3 repurchase the Goods at the price paid by the Buyer less depreciation at the rate the Seller applies to its own equipment. 8.3 If any claim is made or action brought or threatened which alleges infringement of the rights of any third party: 8.3.1 the Buyer shall notify the Seller as soon as it becomes aware of any such claim; 8.3.2 the Seller shall have control over and, at its own cost, shall conduct any such proceedings in such manner as it shall determine; and 8.3.3 the Buyer shall provide all reasonable assistance as the Seller may request. 8.4 The Buyer shall indemnify the Seller against all loss, liability and cost which the Seller incurs in carrying out any work required to be done on or to the Goods or in relation to the Services in accordance with the Buyer's requirements or specifications which give rise to any infringement or alleged infringement of the rights of any third party. 8.5 If the Seller or its employees or agents design the Goods or perform the Services pursuant to a commission from the Buyer (whether to fulfil a Contract or otherwise), any intellectual property rights created in relation to such Goods or Services shall vest in the Seller and the Buyer shall do or procure the doing of all such further acts and execute or procure the execution (as a deed or otherwise) of all such documents as may from time to time be necessary to give full effect to this Condition 8.5. 9. TERMINATION 9.1 The Seller may terminate or suspend the Contract by notice in writing without liability to itself, but without prejudice to any liability on the Buyer’s part accruing before such termination or suspension and treat the Buyer in breach of contract, in the following circumstances: 9.1.1 the Buyer being in breach of any obligation under a Contract or these Conditions; 9.1.2 a meeting being convened, a petition presented, an order made, an effective resolution passed, or notice given for the Buyer's winding up or dissolution (other than for the sole purpose of amalgamation and reconstruction); or 9.1.3 an application being made, or resolved to be made by any meeting of the Buyer's directors or members, for an administration order in relation to it or any party gives or files notice of intention to appoint an administrator of it or such an administrator being appointed; or 9.1.4 an incumbrancer taking possession, or a receiver or manager or administrative receiver being appointed, of the whole or any part of the Buyer's assets; or 9.1.5 the Buyer ceasing or suspending payment of any of its debts or being unable to pay its debts as they fall due within the meaning of section 123 of the Insolvency Act 1986; or 9.1.6 a proposal being made for a composition in satisfaction of the Buyer's debts or a scheme or arrangement of its affairs including a voluntary arrangement within the meaning of part I of the Insolvency Act 1986. 9.2 On termination of a Contract pursuant to Condition 2.3 or 9.1, any indebtedness of the Buyer to the Seller shall become immediately due and payable and the Seller is relieved of any further obligation to supply Goods or perform Services to the Buyer pursuant to that Contract. 10. CONFIDENTIALITY AND SPECIFICATIONS 10.1 The Buyer shall treat all product, customer or business information, drawings, designs and specifications submitted to it by the Seller as confidential and shall not disclose it to any third party without the Seller's prior written consent or use it for any purpose except where authorised to do so by the Seller. 10.2 Condition 10.1 does not apply to information which: 10.2.1 is at the date of disclosure or becomes at any time after that date publicly known other than by the Buyer's breach of this Condition; 10.2.2 can be shown by the Buyer to the Seller's satisfaction to have been known by the Buyer before disclosure by the Seller to the Buyer; 10.2.3 is or becomes available to the Buyer otherwise than from the Seller and free of any restrictions as to its use or disclosure; 10.2.4 is required to be disclosed by law. 10.3 All drawings, designs, specifications and other particulars of dimensions or weight submitted by the Seller are approximate only and the Seller accepts no liability for any deviation from them, nor for any errors, omissions or other defects in any such materials not prepared by the Seller. 11. ASSIGNMENT 11.1 The Buyer may not assign or deal in any way with all or any part of the benefit of, or its rights or benefits under, a Contract without the prior written consent of the Seller. 11.2 The Seller is entitled at any time to assign or deal with the benefit of any Contract, or sub-contract any work relating to any Contract. 12. NOTICES Any notice given by one party to the other in connection with a Contract must be in writing and may be delivered personally or by pre-paid first class post and in the case of post will be deemed to have been given two (2) Working Days after the date of posting. Notices shall be delivered or sent to the last known addresses of the parties or to any other address notified in writing by one party to the other for the purpose of receiving notices in connection with a Contract. Each party may specify by notice to the other a particular individual or office holder to whom any notices served on it are to be addressed, in which case a notice shall not be validly given unless so addressed. 13. SEVERANCE 13.1 If any of these Conditions is found by any court or administrative body of competent jurisdiction to be invalid or unenforceable, such invalidity or unenforceability shall not affect the other Conditions which shall remain in full force and effect. 13.2 If any of these Conditions is so found to be invalid or unenforceable but would cease to be invalid or unenforceable if some part of the provision were deleted, the provision in question shall apply with such modification as may be necessary to make it valid and enforceable. 14. THIRD PARTIES A person who is not party to a Contract shall have no rights under the Contracts (Rights of Third Parties) Act 1999 to enforce any term of such Contract. This condition does not affect any right or remedy of any person which exists or is available otherwise than pursuant to that Act. 15. WAIVER The rights and remedies provided by any Contract may be waived only in writing and specifically, and any failure to exercise or any delay in exercising a right or remedy by the Seller shall not constitute a waiver of that right or remedy or of any other rights or remedies. A waiver of any breach of any of the terms of a Contract or of a default under a Contract shall not constitute a waiver of any other breach or default and shall not affect the other terms of such Contract. 16. VARIATION No variation or alteration of any of the provisions of a Contract or these Conditions shall be effective unless it is in writing and signed by or on behalf of each party. 17. GOVERNING LAW AND JURISDICTION 17.1 A Contract and any matter arising from or in connection with it shall be governed by and construed in accordance with English law. 17.2 Each party irrevocably agrees to submit to the exclusive jurisdiction of the English courts over any claim or matter arising from or in connection with these Conditions.
For details of your local depot, please turn to pages 34-35 Web: www.rom.co.uk Email: (Engineering Services) - engineering@rom.co.uk (Sales) - sales@rom.co.uk
39
ROM Group Health and Safety Statement â&#x20AC;&#x2DC;ROM Group Ltd considers the safety of our workforce and all its activities to be of the highest priority. The Company endeavours to ensure that, at all times, all activities comply fully with all health, safety and other relevant legislation, regulations and guidelines. The Company is actively developing and establishing a Safety Management System in accordance with the specifications of the BS 8800: 2004 Standard. This standard will be applied to all activities throughout the ROM Group of Companiesâ&#x20AC;&#x2122;. Dr Roy Thurston Health & Safety Director
Eastern Avenue, Trent Valley, Lichfield, Staffordshire WS13 6RN. Tel: 0870 011 2883 Fax: 0870 011 2884
Email: (Engineering Services) - engineering@rom.co.uk (Sales) - sales@rom.co.uk
www.rom.co.uk
Major credit cards accepted