IaaCGss11_site analysis_block1

Page 1

BARCELONA 22@ _ BLOCK 1 Cristina Hidalgo Daniela Melo Diana Villarreal


BARCELONA _ 22@ _ BLOCK 1

PUJADES STREET 11 109

12 14 17

8

13 15 16 18 19 20

7 6 5

D'AVILA STREET

D'ALABA STREET

BOGATELL

VINYASSA STREET

M

PAMPLONA STREET

LOCATION

BLUE MANGO THEATRE

Existing configuration of Super Block, charateristics of and industrial area, in transition.

4 2

3 1

LLULL STREET

PARK

N


BARCELONA _ 22@ _ BLOCK 1 PROGRAM

Analysis of existing program inside block #1. Majority of industry, and very low housing percentage.

GREEN AREAS LIGHT INDUSTRIY COMERCIAL HOUSING

N


BARCELONA _ 22@ _ BLOCK 1 BUILT AND UNBUILT

7

11

10

9

8 6

13 12

5

4

15 14 16

2

3

18 17 19

1

20

Synthesis of the volumetric gesture of whats built an unbuilt. Only the street in the middle is open as an urban and public space.

UNBUILT BUILT

N


BARCELONA _ 22@ _ BLOCK 1 STRUCTURES 7

11

10

9

8 6

13 12

5

4

15 14 16

2

3

18 17 19

1

20

LIGHT ST RUC TUR E HEAVY STRU CTU RE

Location of structures wich are mainly open floor plan and used as workshops. Building number 9 is abandoned and not actually in use, even though it is a heavy structure.

LIGHT STRUCTURES HEAVY STRUCTURES

N


BARCELONA _ 22@ _ BLOCK 1 -+++

MOBILITY

Analysis of mobility and most active areas that influence the block. Most mobility marked in the corners and in the middle street of the block.

++ +--

N


BARCELONA _ 22@ _ BLOCK 1 V1

ECOTECT _ RADIATION SUMMER 7

11

10

9

8 6

13 12

5

4

15 14 16

2

3

18 17 19

1

20

VIEW 1

V2

Radiation shows that the corner North, which has also the most masive volumes, receives less light than South side in all of the summer time, which is when most radiation is emitted.

VIEW 2 691000+ Wh/m2 345950 Wh/m2 900 Wh/m2

N


BARCELONA _ 22@ _ BLOCK 1 V1

ECOTECT _ SHADOWS SUMMER 7

11

10

9

8 6

13 12

5

4

15 14 16

2

3

18 17 19

1

20

VIEW 1

V2

Shadow analysis reveals how during most of the Summer season, de North fachade has more shadows than South.

VIEW 2

N


BARCELONA _ 22@ _ BLOCK 1 V1

ECOTECT _ SHADOWS SUMMER 7

11

10

9

8 6

13 12

5

4

15 14 16

2

3

18 17 19

1

20

VIEW 1

V2

During the Winter, shadow analysis show also that North side of the block produce more shadows because of the Sun position.

VIEW 2

N


BARCELONA _ 22@ _ BLOCK 1 CONSUMPTION 7

11

10

9

8 6

13

GENERAL m2/month CONSUMPTIONS PER PROGRAM

12

5

4

15

program

energy consumption (kw/m2)water consumption (m3/m2) co2 emissions (g/m2)

housing office comercial heavy industry light industry services green area

5,14 12,87 17,44 30,3 24,6 15,5 1,2

Block

0,5 0,25 0,05 1 0,75 0,4 1,6

14

930,34 2329,47 3156,64 5484,3 4452,6 2805,5 217,2

m2

16

2

3

18 17 19

1

20

Building code

program

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

101a 101b 102a 102b 103a 103b 104a 104b 105a 105b 106a 106b 107a 107b 108a 108b 109a 109b 110a 110b

Light Industry Office Office Office Office Office Light Industry Light Industry Light Industry Light Industry Comercial Office Light Industry Office Comercial None Light Industry Housing Light Industry None

1250 30750 5000 64350 603 7760,61 2412 31042,44 773 9948,51 773 9948,51 506 12447,6 1012 24895,2 829 20393,4 829 20393,4 1016 17719,04 9912 127567,44 346 8511,6 2422 31171,14 641 11179,04 0 0 380 9348 1520 7812,8 330 8118 0 0

energy

937,5 1250 150,75 603 193,25 193,25 379,5 759 621,75 621,75 50,8 2478 259,5 605,5 32,05 0 285 760 247,5 0

5565750 11647350 1404670,4 5618681,6 1800680,3 1800680,3 2253015,6 4506031,2 3691205,4 3691205,4 3207146,2 23089707 1540599,6 5641976,3 2023406,2 0 1691988 1414116,8 1469358 0

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

111a 111b 112a 112b 113a 113b 114a 114b 115a 115b 116a 116b 117a 117b 118a 118b 119a 119b 120a 120b 121a 121b

Light Industry None Light Industry None Light Industry None Light Industry None Housing Housing Light Industry None Light Industry None Comercial None Light Industry None Light Industry None Green Areas None

788 0 641 0 243 0 627 0 350 1750 259 0 1091 0 210 0 242 0 166 0 1293 0

591 0 480,75 0 182,25 0 470,25 0 175 875 194,25 0 818,25 0 10,5 0 181,5 0 124,5 0 2068,8 0

3508648,8 0 2854116,6 0 1081981,8 0 2791780,2 0 325619 1628095 1153223,4 0 4857786,6 0 662894,4 0 1077529,2 0 739131,6 0 280839,6 0

19384,8 0 15768,6 0 5977,8 0 15424,2 0 1799 8995 6371,4 0 26838,6 0 3662,4 0 5953,2 0 4083,6 0 1551,6 0

38214 569166,93

water

co2

Consumption data to analize the energy, water, and CO2 emisions on Block #1.

16600,15 103019214

07/16/201107/16/2011

N


BARCELONA _ 22@ _ BLOCK 1 CONSUMPTION ENERGY

Most consumption of energy in the higher buildings in the North-East side of the Block.

150000-90000 KW/M2 90000-30000 KW/M2 30000-10000 KW/M2 10000- KW/M2

N


BARCELONA _ 22@ _ BLOCK 1 CONSUMPTION WATER

In the light industrial area of the South-West side is where there is less water consumption.

15000-10000 M3/M2 10000-5000 M3/M2 5000-1000 M3/M2 1000- M3/M2

N


BARCELONA _ 22@ _ BLOCK 1 CONSUMPTION CO2

CO2 emition is higher in the two biggest buildings of 5 and 8 floors of the Block.

10-20 MILLION G/M2 5-10 MILLION G/M2 1-5 MILLION G/M2 0-1 MILLION G/M2

N


BARCELONA _ 22@ _ BLOCK 1 URBAN ESTRATEGY

M

Relationships beetween network of the Super Block. Program and new configurations change the movement of energy. Configuration and flexible program, equals new mobility and activation in the site.

T R A N S P O R T A T IO N E D U C A T IO N A L / C U L T U R A L

H O U S IN G

LE AS U R E

I N T E R S E C T I N G A C T IV IT I E S

C O N E C T IN G A C T I V I T IE S

M A IN A X E S

N


BARCELONA _ 22@ _ BLOCK 1 URBAN ESTRATEGY

T R A N S P O R T A T IO N E D U C A T IO N A L / C U L T U R A L

H O U S IN G

LE AS U R E

I N T E R S E C T I N G A C T IV IT I E S

C O N E C T IN G A C T I V I T IE S

M A IN A X E S

N


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.