Categories ; Posterior, Grafting, Multiple Implants, Nobel Biocare
Copyright Š 2012 Idondivi, Inc. All rights reserved.
Patient reports loss of two molars about 1 year ago
Copyright Š 2012 Idondivi, Inc. All rights reserved
2
Molar site appears to have grafting material
Copyright Š 2012 Idondivi, Inc. All rights reserved
3
Mandibular canal identified on PA radiograph
Copyright Š 2012 Idondivi, Inc. All rights reserved
4
Two implants planned
Copyright Š 2012 Idondivi, Inc. All rights reserved
5
# 19 site
Copyright Š 2012 Idondivi, Inc. All rights reserved
# 18 site
6
BLP’s placed in relation to bone volume, bone width and screw retained crowns.
Copyright Š 2012 Idondivi, Inc. All rights reserved
7
BLP’s lock in the bucco-lingual and shoulder of the implants
Copyright © 2012 Idondivi, Inc. All rights reserved
8
Mesio-Distal ideal positioning
Copyright Š 2012 Idondivi, Inc. All rights reserved
9
BLP’s overlap sufficiently, radiograph is diagnostic , no need for correction, so 0degree rotation blocks ( green) are indicated
Copyright Š 2012 Idondivi, Inc. All rights reserved
10
Poor integration of graft material.
Copyright Š 2012 Idondivi, Inc. All rights reserved
11
# 18 site prepared for 8.5 mm implant
Copyright Š 2012 Idondivi, Inc. All rights reserved
12
# 18 , a 1.5 mm alveolectomy planned due to a pointy ridge. Note defect in # 19 site
Copyright Š 2012 Idondivi, Inc. All rights reserved
13
Due to failed bone graft, osteotomy has to be increased from planned 8.5 mm to created adequate initial stability. 10 mm osteotomy ( 23 – 10 = 13 – red flexistop @ 3 = 10 MM )
Copyright © 2012 Idondivi, Inc. All rights reserved
14
11.5 mm osteotomy
Copyright Š 2012 Idondivi, Inc. All rights reserved
15
11.5 mm osteotomy, decision is made to increase to 13 mm, due to safe distance to mandibular canal
Copyright Š 2012 Idondivi, Inc. All rights reserved
16
Note large defect around osteotomy # 19
Copyright Š 2012 Idondivi, Inc. All rights reserved
17
Prep and placement of 4.3 x 8.5 Nobel Active implant # 18 site. Using Astra Facilitate drills.
Copyright Š 2012 Idondivi, Inc. All rights reserved
18
13 x 4.3 MM Nobel Active for # 19 site
Copyright Š 2012 Idondivi, Inc. All rights reserved
19
4-5 mm of implant exposed, buccal and lingual cortical plates are intact.
Copyright Š 2012 Idondivi, Inc. All rights reserved
20
Grafting with “ Socket Graft Putty”
Copyright © 2012 Idondivi, Inc. All rights reserved
21
Covered with Resorbable collagen membrane for covered healing
Copyright Š 2012 Idondivi, Inc. All rights reserved
22
Implants placed in planned position, only # 19 is 4.5 mm longer to created adequate initial stability
Copyright Š 2012 Idondivi, Inc. All rights reserved
23