Prototype : same concept different look Categories : Posterior, grafting, multiple implants, prototype, Nobel Biocare
Copyright Š 2011 Idondivi, Inc. All rights reserved.
Failing 3 unit bridge abutment tooth # 29
Copyright Š 2011 Idondivi, Inc. All rights reserved
2
Cast is cut at proposed implant axis
Copyright Š 2011 Idondivi, Inc. All rights reserved
3
Implant angle based on prosthetic outcome. More buccal on site were premolar is to be extracted, anticipating buccal boneloss.
Copyright Š 2011 Idondivi, Inc. All rights reserved
4
Prototype BLP glued into place. Determining bucco-lingual position and the top of the implant
Copyright Š 2011 Idondivi, Inc. All rights reserved
5
Prototype BLP’s positioned for side by side implants
Copyright Š 2011 Idondivi, Inc. All rights reserved
6
Surgical guide in place while tooth # 29 and pontic # 30 have not yet been removed.
Copyright Š 2011 Idondivi, Inc. All rights reserved
7
X-ray not shot perpendicular. Double view of RIR’s. Current RIR’s are fully radio- opaque , while prototypes only on the outlines
Copyright © 2011 Idondivi, Inc. All rights reserved
8
X-ray shot correctly, overlap RIR. 7 degree rotation block indicated to engage some native bone on the mesial , so on purpose not following the existing alveolus
Copyright Š 2011 Idondivi, Inc. All rights reserved
9
Guided surgery does not mean flapless surgery
Copyright Š 2011 Idondivi, Inc. All rights reserved
10
Foramen relative to tooth apex as visualized on PA radiograph
Copyright Š 2011 Idondivi, Inc. All rights reserved
11
Very precise depth control is needed as we are close to the foramen , Drill set at 7 mm
Copyright Š 2011 Idondivi, Inc. All rights reserved
12
Very precise depth control is needed as we are close to the foramen , Drill set at 10 mm. Still short from the apex. In this way we are always safely away from the foramen.
Copyright Š 2011 Idondivi, Inc. All rights reserved
13
Implant placement and bone augmentation
Copyright Š 2011 Idondivi, Inc. All rights reserved
14
Green line bottom of the implant
Copyright Š 2011 Idondivi, Inc. All rights reserved
15
Green line bottom of the implant
Copyright Š 2011 Idondivi, Inc. All rights reserved
16
Actual distance between implant tip and foramen 2.9 mm, while on 2 dimensial PA radiograph it would appear to be 1.4 mm
Copyright Š 2011 Idondivi, Inc. All rights reserved
17
Non resorbable membrane protect bone augmentation and will develop abundant keratinized gingiva.
Copyright Š 2011 Idondivi, Inc. All rights reserved
18
8 weeks post placement
Copyright Š 2011 Idondivi, Inc. All rights reserved
19
Restored with two single crowns
Copyright Š 2011 Idondivi, Inc. All rights reserved
20