Clinical Case: Gordon-E

Page 1

Prototype : same concept different look Categories : Posterior, grafting, multiple implants, prototype, Nobel Biocare

Copyright Š 2011 Idondivi, Inc. All rights reserved.


Failing 3 unit bridge abutment tooth # 29

Copyright Š 2011 Idondivi, Inc. All rights reserved

2


Cast is cut at proposed implant axis

Copyright Š 2011 Idondivi, Inc. All rights reserved

3


Implant angle based on prosthetic outcome. More buccal on site were premolar is to be extracted, anticipating buccal boneloss.

Copyright Š 2011 Idondivi, Inc. All rights reserved

4


Prototype BLP glued into place. Determining bucco-lingual position and the top of the implant

Copyright Š 2011 Idondivi, Inc. All rights reserved

5


Prototype BLP’s positioned for side by side implants

Copyright Š 2011 Idondivi, Inc. All rights reserved

6


Surgical guide in place while tooth # 29 and pontic # 30 have not yet been removed.

Copyright Š 2011 Idondivi, Inc. All rights reserved

7


X-ray not shot perpendicular. Double view of RIR’s. Current RIR’s are fully radio- opaque , while prototypes only on the outlines

Copyright © 2011 Idondivi, Inc. All rights reserved

8


X-ray shot correctly, overlap RIR. 7 degree rotation block indicated to engage some native bone on the mesial , so on purpose not following the existing alveolus

Copyright Š 2011 Idondivi, Inc. All rights reserved

9


Guided surgery does not mean flapless surgery

Copyright Š 2011 Idondivi, Inc. All rights reserved

10


Foramen relative to tooth apex as visualized on PA radiograph

Copyright Š 2011 Idondivi, Inc. All rights reserved

11


Very precise depth control is needed as we are close to the foramen , Drill set at 7 mm

Copyright Š 2011 Idondivi, Inc. All rights reserved

12


Very precise depth control is needed as we are close to the foramen , Drill set at 10 mm. Still short from the apex. In this way we are always safely away from the foramen.

Copyright Š 2011 Idondivi, Inc. All rights reserved

13


Implant placement and bone augmentation

Copyright Š 2011 Idondivi, Inc. All rights reserved

14


Green line bottom of the implant

Copyright Š 2011 Idondivi, Inc. All rights reserved

15


Green line bottom of the implant

Copyright Š 2011 Idondivi, Inc. All rights reserved

16


Actual distance between implant tip and foramen 2.9 mm, while on 2 dimensial PA radiograph it would appear to be 1.4 mm

Copyright Š 2011 Idondivi, Inc. All rights reserved

17


Non resorbable membrane protect bone augmentation and will develop abundant keratinized gingiva.

Copyright Š 2011 Idondivi, Inc. All rights reserved

18


8 weeks post placement

Copyright Š 2011 Idondivi, Inc. All rights reserved

19


Restored with two single crowns

Copyright Š 2011 Idondivi, Inc. All rights reserved

20


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.